WorldWideScience

Sample records for experimental evaluation techniques

  1. The development of human factors experimental evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Bong Shick; Oh, In Suk; Cha, Kyung Ho; Lee, Hyun Chul; Park, Geun Ok; Cheon, Se Woo; Suh, Sang Moon

    1997-07-01

    New human factors issues, such as evaluation of information navigation, the consideration of operator characteristics, and operator performance assessment, related to the HMI design based on VDUs are being risen. Thus, in order to solve these human factors issues, this project aims to establish the experimental technologies including the techniques for experimental design, experimental measurement, data collection and analysis, and to develop ITF (Integrated Test Facility) suitable for the experiment of HMI design evaluation. For the establish of the experimental data analysis and evaluation methodologies, we developed as the following: (1) a paradigm for human factors experimentation including experimental designs, procedures, and data analysis. (2) the methods for the assessment of operator`s mental workload (3) DAEXESS (data analysis and experiment evaluation supporting system). Also, we have established a experiment execution technologies through the preliminary experiments, such as the suitability evaluation of information display on a LSDP, the evaluation of information display on a LSDP, the evaluation of computerized operation procedure and an experiment of advanced alarm system (ADIOS). Finally, we developed the ITF including human machine simulator, telemetry system, an eye tracking system, an audio/video data measurement system, and three dimensional micro behaviour analysis system. (author). 81 refs., 68 tabs., 73 figs.

  2. Technique of experimental evaluation of cloud environment attacks detection accuracy

    Directory of Open Access Journals (Sweden)

    Sergey A. Klimachev

    2018-05-01

    Full Text Available The article is devoted to research of efficiency evaluation of IDS used for dynamic and complex organizational and technical structure computing platform guard. The components of the platform have a set of heterogeneous parameters. Analysis of existing IDS evaluation technique revealed shortcomings in justification of quantitative metrics that describe the efficiency and reliability IDS resolving. This makes if difficult to prove IDS evaluation technique. The purpose of the study is to increase IDS evaluation objectivity. To achive the purpose it is necessary to develop the correct technique, tools, experimental stand. The article proposes the results of development and approbation of the technique of IDS efficiency evaluation and software for it. The technique is based on defining of optimal set of attack detection accuracy scores. The technique and the software allow solving problems of comparative analysis of IDS that have similar functionality. As a result of the research, a number of task have been solved, including the selection of universal quantitative metrics for attack detection accuracy evaluation, the defining of summarised attack detection accuracy evaluation metric based on defining of pareto-optimal set of scores that ensure the confidentiality, integrity and accessibility of cloud environment information and information resources,  the development of a functional model,  a functional scheme and a software for cloud environment IDS research.

  3. Experimental evaluation of a quasi-modal parameter based rotor foundation identification technique

    Science.gov (United States)

    Yu, Minli; Liu, Jike; Feng, Ningsheng; Hahn, Eric J.

    2017-12-01

    Correct modelling of the foundation of rotating machinery is an invaluable asset in model-based rotor dynamic study. One attractive approach for such purpose is to identify the relevant modal parameters of an equivalent foundation using the motion measurements of rotor and foundation at the bearing supports. Previous research showed that, a complex quasi-modal parameter based system identification technique could be feasible for this purpose; however, the technique was only validated by identifying simple structures under harmonic excitation. In this paper, such identification technique is further extended and evaluated by identifying the foundation of a numerical rotor-bearing-foundation system and an experimental rotor rig respectively. In the identification of rotor foundation with multiple bearing supports, all application points of excitation forces transmitted through bearings need to be included; however the assumed vibration modes far outside the rotor operating speed cannot or not necessary to be identified. The extended identification technique allows one to identify correctly an equivalent foundation with fewer modes than the assumed number of degrees of freedom, essentially by generalising the technique to be able to handle rectangular complex modal matrices. The extended technique is robust in numerical and experimental validation and is therefore likely to be applicable in the field.

  4. The development of human factors experimental evaluation techniques -The development of human factors technologies-

    International Nuclear Information System (INIS)

    Sim, Bong Shick; Oh, In Seok; Cha, Kyeong Ho; Lee, Hyun Chul

    1994-04-01

    In the 2nd year of the research project for the development of human factors evaluation techniques, we first defined the experimental target systems by the comparison study of the advanced control rooms proposed by foreign countries in order to make the experiment feasible and realistic for the 10 experimental items selected in the first year of the project. Then we have decided to confine our research on the big board overview panel and operator workstations. Following the development of selection criteria for our research interest, we have identified the design variables which may influence the performance of the operator by the functional analysis. The experimental variables which will be used for the evaluation of the proposed items are then defined by the relational analysis between evaluation items and design variables and they are classified by the characteristics of the measurement data. The functional requirements of ITF are developed to accommodate the necessary functions for carrying out the 10 evaluation items. The functional requirements for each sub-system of ITF have been developed with the experimental paradigm of APTEA. Finally we have reviewed the compact nuclear simulator (CNS) at KAERI from the point of view of jyman factors guidelines/principles and proposed the two possible layouts for the experimental apparatus for the evaluation of display alternative and operational procedure. (Author)

  5. Experimental program for development and evaluation of nondestructive assay techniques for plutonium holdup

    International Nuclear Information System (INIS)

    Brumbach, S.B.

    1977-05-01

    An outline is presented for an experimental program to develop and evaluate nondestructive assay techniques applicable to holdup measurement in plutonium-containing fuel fabrication facilities. The current state-of-the-art in holdup measurements is reviewed. Various aspects of the fuel fabrication process and the fabrication facility are considered for their potential impact on holdup measurements. The measurement techniques considered are those using gamma-ray counting, neutron counting, and temperature measurement. The advantages and disadvantages of each technique are discussed. Potential difficulties in applying the techniques to holdup measurement are identified. Experiments are proposed to determine the effects of such problems as variation in sample thickness, in sample distribution, and in background radiation. These experiments are also directed toward identification of techniques most appropriate to various applications. Also proposed are experiments to quantify the uncertainties expected for each measurement

  6. Experimental evaluation of optimal Vehicle Dynamic Control based on the State Dependent Riccati Equation technique

    NARCIS (Netherlands)

    Alirezaei, M.; Kanarachos, S.A.; Scheepers, B.T.M.; Maurice, J.P.

    2013-01-01

    Development and experimentally evaluation of an optimal Vehicle Dynamic Control (VDC) strategy based on the State Dependent Riccati Equation (SDRE) control technique is presented. The proposed nonlinear controller is based on a nonlinear vehicle model with nonlinear tire characteristics. A novel

  7. Experimental Technique of Titanium Fire in Aero-engine

    Directory of Open Access Journals (Sweden)

    MI Guangbao

    2016-06-01

    Full Text Available Titanium fire is the typical catastrophic fault in the aero-engine. Aiming at the urgent demand for experimental technique of titanium fire from advanced high thrust-weight ratio aero-engine, the combustion technology and theory of titanium alloy based on friction oxygen concentration method (FOC were systematically studied. The evaluation method of fireproof property and the friction ignition model were built, and the fireproof mechanism was illustrated. By generalizing recent progress in experimental technique of titanium fire from three levels, including evolutionary rule, mechanism and prevention and control technology, the ideas and directions of experimental technique associated with the application research of titanium fire in the future were proposed, namely overall evaluation of fireproof property close to air flow environment of the aero-engine, prediction model of fireproof property and experimental verification of fireproof technique under the air flow environment of aero-engine. It is necessary to establish the prevention system of titanium fire in aero-engine, which contributes to the realization of "full titanium" in compressor and to the increase of high thrust-weight ratio.

  8. Development of human factors experimental evaluation techniques - Human factors design and evaluation of the main control room of atomic power plants using visual display terminals

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sung Ho; Chung, Min Kyun; Choi, Kyung Lim; Song, Young Woong; Eoh, Hong Joon; Lee, In Suk; Kim, Bom Soo; Yeo, Yun Shin; Lee, Haeo Sun [Pohang University of Science and Technology, Pohang (Korea, Republic of)

    1995-07-01

    This study was conducted to build a prototype of the operator interface on a visual display terminal, and to provide a framework for using and applying prototyping techniques. A typical subsystem of an MCR was prototyped and validated by operator testing. Lessons learned during the development as well as prototyping techniques were described in this report for an efficient development. In addition, human factors experimental plans were surveyed and summarized for evaluating new design alternatives as well as the current design of the operator interface. The major results of this study are listed as follow: A method for designing an operator interface prototype on a VDT, A prototype of the operator interface of a typical subsystem, Guidelines for applying prototyping techniques, Characteristics and major considerations of experimental plans, Guidelines for applying prototyping techniques, Characteristics and major considerations of experimental plans, Guidelines for analyzing experimental data, A paradigm for human factors experimentation including experimental designs, procedures, and data analyses. 27 refs., 60 tabs., 47 figs. (author)

  9. Strongly correlated systems experimental techniques

    CERN Document Server

    Mancini, Ferdinando

    2015-01-01

    The continuous evolution and development of experimental techniques is at the basis of any fundamental achievement in modern physics. Strongly correlated systems (SCS), more than any other, need to be investigated through the greatest variety of experimental techniques in order to unveil and crosscheck the numerous and puzzling anomalous behaviors characterizing them. The study of SCS fostered the improvement of many old experimental techniques, but also the advent of many new ones just invented in order to analyze the complex behaviors of these systems. Many novel materials, with functional properties emerging from macroscopic quantum behaviors at the frontier of modern research in physics, chemistry and materials science, belong to this class of systems. The volume presents a representative collection of the modern experimental techniques specifically tailored for the analysis of strongly correlated systems. Any technique is presented in great detail by its own inventor or by one of the world-wide recognize...

  10. Experimental technique of neutron reflection

    International Nuclear Information System (INIS)

    Chen Bo; Huang Chaoqiang; Li Xinxi

    2006-12-01

    It is presented that the classifications, structures and components of neutron reflectometer (NR), as well s functions and parameters of each components, detailed characters of NR facility 'PRN-2M'. Based on the practical experiments, the basic experimental techniques, the measurement and the related experimental settings are described, including the choice of experimental conditions, adjustments of polarized neutron beam line, basic experimental technique and approach of measurement. The above can be an instruction for NR experiments and a reference for NR construction. (authors)

  11. Evaluation of in-vehicle HMI using occlusion techniques: experimental results and practical implications.

    Science.gov (United States)

    Baumann, Martin; Keinath, Andreas; Krems, Josef F; Bengler, Klaus

    2004-05-01

    Despite the usefulness of new on-board information systems one has to be concerned about the potential distraction effects that they impose on the driver. Therefore, methods and procedures are necessary to assess the visual demand that is connected to the usage of an on-board system. The occlusion-method is considered a strong candidate as a procedure for evaluating display designs with regard to their visual demand. This paper reports results from two experimental studies conducted to further evaluate this method. In the first study, performance in using an in-car navigation system was measured under three conditions: static (parking lot), occlusion (shutter glasses), and driving. The results show that the occlusion-procedure can be used to simulate visual requirements of real traffic conditions. In a second study the occlusion method was compared to a global evaluation criterion based on the total task time. It can be demonstrated that the occlusion method can identify tasks which meet this criterion, but are yet irresolvable under driving conditions. It is concluded that the occlusion technique seems to be a reliable and valid method for evaluating visual and dialogue aspects of in-car information systems.

  12. Experimental Techniques

    International Nuclear Information System (INIS)

    Fournier, D.; Serin, L.

    1995-01-01

    Experimental techniques to be used in the new generation of high energy physics are presented. The emphasis is put on the new ATLAS and CMS detectors for the CERN LHC. For the most important elements of these detectors, a description of the underlying physics processes is given, sometimes with reference to comparable detectors used in the past. Some comparative global performances of the two detectors are also given, with reference to benchmark physics processes (detection of the Higgs boson in various mass regions, etc). (author)

  13. Effects of a Peer Evaluation Technique on Nursing Students' Anxiety Levels.

    Science.gov (United States)

    Stewart, Patricia; Greene, Debbie; Coke, Sallie

    2017-11-16

    Techniques to help decrease students' stress and anxiety during a nursing program can be beneficial to their overall health and mental well-being. A quasi-experimental design was used to examine if a peer evaluation technique during clinical skill practice sessions decreases anxiety prior to skill performance evaluation with nursing faculty. Participant feedback supports the integration of a peer evaluation technique when learning clinical skills.

  14. Natural gas hydrates. Experimental techniques and their applications

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Yuguang; Liu, Changling (eds.) [Qingdao Institute of Marine Geology (China). Gas Hydrate Laboratory

    2013-07-01

    Focuses on gas hydrate experiment in laboratory. Intends to provide practical significant parameters for gas hydrate exploration and exploitation in the oceanic and permafrost environments. Consists of different themes that present up-to-date information on hydrate experiments. ''Natural Gas Hydrates: Experimental Techniques and Their Applications'' attempts to broadly integrate the most recent knowledge in the fields of hydrate experimental techniques in the laboratory. The book examines various experimental techniques in order to provide useful parameters for gas hydrate exploration and exploitation. It provides experimental techniques for gas hydrates, including the detection techniques, the thermo-physical properties, permeability and mechanical properties, geochemical abnormalities, stability and dissociation kinetics, exploitation conditions, as well as modern measurement technologies etc.

  15. The full bayesian evaluation technique and its application to isotopes of structural materials

    International Nuclear Information System (INIS)

    Neudecker, D.

    2012-01-01

    In Nuclear Data evaluations, experimental and model knowledge is combined to data sets suitable for nuclear applications. The development of new nuclear technologies (e.g. fusion reactor) resulted in new demands concerning Nuclear Data: The energy range of evaluations should be extended up to 150 MeV and uncertainties should be provided in form of covariance matrices. This extension is not straight-forward because experimental data are scarce and nuclear models become important with increasing energy. The set-up of a proper evaluation procedure is challenging and there is currently a world-wide effort ongoing. The goal of this thesis was to develop an evaluation method - the Full Bayesian Evaluation Technique - which tackles these demands in a mathematical and physical well-defined manner and provides evaluated angle-integrated cross sections and covariance matrices from the unresolved resonance range to 150 MeV for incoming neutrons. Starting from previous works of the Viennese group, we used Bayesian Statistics which offers a well-defined formalism to combine experimental and prior knowledge. The prior knowledge consists of cross sections given by nuclear models and associated covariance matrices. The latter contain uncertainties stemming from the limited knowledge of the parameters and model deficiencies. While parameter uncertainties are accounted for in many modern Nuclear Data evaluation techniques, uncertainties from model defects were first implemented in the Full Bayesian Evaluation Technique. It turned out that considering model defect uncertainties can visibly improve the evaluated output in the case of a deficient model. In addition, great emphasis was given to estimate experimental uncertainties and include correlations between different experimental data points of single and different experiments. It could be shown that considering experimental correlations leads to evaluated uncertainties in agreement with the correlated systematic uncertainties of

  16. Dynamic Tensile Experimental Techniques for Geomaterials: A Comprehensive Review

    Science.gov (United States)

    Heard, W.; Song, B.; Williams, B.; Martin, B.; Sparks, P.; Nie, X.

    2018-01-01

    This review article is dedicated to the Dynamic Behavior of Materials Technical Division for celebrating the 75th anniversary of the Society for Experimental Mechanics (SEM). Understanding dynamic behavior of geomaterials is critical for analyzing and solving engineering problems of various applications related to underground explosions, seismic, airblast, and penetration events. Determining the dynamic tensile response of geomaterials has been a great challenge in experiments due to the nature of relatively low tensile strength and high brittleness. Various experimental approaches have been made in the past century, especially in the most recent half century, to understand the dynamic behavior of geomaterials in tension. In this review paper, we summarized the dynamic tensile experimental techniques for geomaterials that have been developed. The major dynamic tensile experimental techniques include dynamic direct tension, dynamic split tension, and spall tension. All three of the experimental techniques are based on Hopkinson or split Hopkinson (also known as Kolsky) bar techniques and principles. Uniqueness and limitations for each experimental technique are also discussed.

  17. Techniques used for charged particle nuclear data evaluation at CNDC

    International Nuclear Information System (INIS)

    Zhuang Youxiang; Sun Zuxun

    1993-01-01

    The methods and techniques used for Charged Particle Nuclear Data (CPND) evaluation at Chinese Nuclear Data Center (CNDC) are summarized, including compilation and evaluation of experimental data, nuclear reaction theory and model calculation, systematics research and comprehensive recommendation etc

  18. Experimental techniques and measurement accuracies

    International Nuclear Information System (INIS)

    Bennett, E.F.; Yule, T.J.; DiIorio, G.; Nakamura, T.; Maekawa, H.

    1985-02-01

    A brief description of the experimental tools available for fusion neutronics experiments is given. Attention is paid to error estimates mainly for the measurement of tritium breeding ratio in simulated blankets using various techniques

  19. Experimental techniques; Techniques experimentales

    Energy Technology Data Exchange (ETDEWEB)

    Roussel-Chomaz, P. [GANIL CNRS/IN2P3, CEA/DSM, 14 - Caen (France)

    2007-07-01

    This lecture presents the experimental techniques, developed in the last 10 or 15 years, in order to perform a new class of experiments with exotic nuclei, where the reactions induced by these nuclei allow to get information on their structure. A brief review of the secondary beams production methods will be given, with some examples of facilities in operation or under project. The important developments performed recently on cryogenic targets will be presented. The different detection systems will be reviewed, both the beam detectors before the targets, and the many kind of detectors necessary to detect all outgoing particles after the reaction: magnetic spectrometer for the heavy fragment, detection systems for the target recoil nucleus, {gamma} detectors. Finally, several typical examples of experiments will be detailed, in order to illustrate the use of each detector either alone, or in coincidence with others. (author)

  20. Com-scan techniques for material evaluation

    International Nuclear Information System (INIS)

    Jayakumar, T.K.; Naik, A.D.

    1996-01-01

    Presently a variety of products at various stages of production are being tested using NDT methods for ensuring their quality. The conventional NDT methods such as RT, UT, PT, MPT along with acoustic emission techniques are often employed for the purpose. However, the ever increasing demands for a comprehensive quality assurance of products necessitates newer avenues in testing methods to overcome certain inadequacies of conventional testing. This paper proposes Compton back-scatter technique as an additional alternative NDT tool for various measurements. When the radiation strikes material a small percentage of incident radiation scatters back with reduced energy. The back-scattered radiation is picked up by a digital backscatter gauge and analysed. The paper discusses experimental work carried out at the laboratory consisting of parameter evaluation, source detector geometry, back-scatter response for material, area effects, thickness and blockage measurements. The paper briefly discusses on-stream measurements carried out with the above experimental gauge. The paper deals with selection and comparison of measurements with those of ultrasonics. It also discusses the advantages of the radiation back-scatter testing. The paper recommends Com-scan back-scatter technique as a supplementary tool along with conventional testing. (author)

  1. Differential sensor in front photopyroelectric technique: II. Experimental

    International Nuclear Information System (INIS)

    Ivanov, R; Moreno, I; Araujo-Andrade, C; MarIn, E; Cruz-Orea, A; Pichardo-Molina, J L

    2009-01-01

    We describe the differential cell design and the experimental (optical and electronic) setup for the differential front photopyroelectric technique, whose theory has been developed in the first part of this paper (Ivanov et al 2008 J. Phys. D: Appl. Phys. 41 085106). We will show first how the direct (non-differential) front photopyroelectric theory described in our previous paper reproduces well the experimental results. The usefulness of the differential technique is demonstrated by means of experimental measurements of the thermal effusivity in binary ethanol-water and glycerol-water mixtures, based on a theoretical methodology that simplifies the measurement procedure and diminishes the experimental uncertainty.

  2. Differential sensor in front photopyroelectric technique: II. Experimental

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, R; Moreno, I; Araujo-Andrade, C [Facultad de Fisica, Universidad Autonoma de Zacatecas, Calz. Solidaridad Esquina Paseo de la Bufa s/n, CP 98060, Zacatecas, Zac. (Mexico); MarIn, E [Centro de Investigacion en Ciencia Aplicada y TecnologIa Avanzada-Instituto Politecnico Nacional, Legaria 694, Col. Irrigacion, CP 11500, Mexico D.F. (Mexico); Cruz-Orea, A [Departamento de Fisica, CINVESTAV-IPN, Av. IPN No. 2508, Col. San Pedro Zacatenco, CP 07360, Mexico D.F. (Mexico); Pichardo-Molina, J L, E-mail: rumen@fisica.uaz.edu.m [Centro de Investigaciones en Optica, Loma del Bosque 115, Loma del Campestre, CP 37150, Leon, Guanajuato (Mexico)

    2009-06-21

    We describe the differential cell design and the experimental (optical and electronic) setup for the differential front photopyroelectric technique, whose theory has been developed in the first part of this paper (Ivanov et al 2008 J. Phys. D: Appl. Phys. 41 085106). We will show first how the direct (non-differential) front photopyroelectric theory described in our previous paper reproduces well the experimental results. The usefulness of the differential technique is demonstrated by means of experimental measurements of the thermal effusivity in binary ethanol-water and glycerol-water mixtures, based on a theoretical methodology that simplifies the measurement procedure and diminishes the experimental uncertainty.

  3. Evaluation of Building Projects Using Earned Value Technique ...

    African Journals Online (AJOL)

    This study evaluates building construction projects using the Earned Value Analysis technique, the Experimental Approach, and Value Concept Analysis. The aim was to compare the cost incurred for an identified amount of work done on a project with the cost budgeted for the same work. The results were used to calculate ...

  4. Experimental evaluation of earthquake induced relay chattering

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.; Hofmayer, C.; Shteyngart, S.

    1990-01-01

    An experimental evaluation of relay performance under vibratory environments is discussed in this paper. Single frequency excitation was used for most tests. Limited tests were performed with random multifrequency inputs. The capacity of each relay was established based on a two-millisecond chatter criterion. The experimental techniques are described and the effects of parameters in controlling the relay capacity levels are illustrated with test data. A wide variation of the capacity levels was observed due to the influence of parameters related to the design of the relay and nature of the input motion. 3 refs., 15 figs

  5. Experimental techniques

    International Nuclear Information System (INIS)

    Roussel-Chomaz, P.

    2007-01-01

    This lecture presents the experimental techniques, developed in the last 10 or 15 years, in order to perform a new class of experiments with exotic nuclei, where the reactions induced by these nuclei allow to get information on their structure. A brief review of the secondary beams production methods will be given, with some examples of facilities in operation or under project. The important developments performed recently on cryogenic targets will be presented. The different detection systems will be reviewed, both the beam detectors before the targets, and the many kind of detectors necessary to detect all outgoing particles after the reaction: magnetic spectrometer for the heavy fragment, detection systems for the target recoil nucleus, γ detectors. Finally, several typical examples of experiments will be detailed, in order to illustrate the use of each detector either alone, or in coincidence with others. (author)

  6. The development of human factors technologies -The development of human factors experimental evaluation techniques-

    International Nuclear Information System (INIS)

    Shim, Bong Sik; Oh, In Suk; Cha, Kyung Hoh; Lee, Hyun Chul

    1995-07-01

    In this year, we studied the followings: 1) Development of operator mental workload evaluation techniques, 2) Development of a prototype for preliminary human factors experiment, 3) Suitability test of information display on a large scale display panel, 4) Development of guidelines for VDU-based control room design, 5) Development of integrated test facility (ITF). 6) Establishment of an eye tracking system, and we got the following results: 1) Mental workload evaluation techniques for MMI evaluation, 2) PROTOPEX (PROTOtype for preliminary human factors experiment) for preliminary human factors experiments, 3) Usage methods of APTEA (Analysis-Prototyping-Training-Experiment-Analysis) experiment design, 4) Design guidelines for human factors verification, 5) Detail design requirements and development plan of ITF, 6) Eye movement measurement system. 38 figs, 20 tabs, 54 refs. (Author)

  7. Statistical analysis of correlated experimental data and neutron cross section evaluation

    International Nuclear Information System (INIS)

    Badikov, S.A.

    1998-01-01

    The technique for evaluation of neutron cross sections on the basis of statistical analysis of correlated experimental data is presented. The most important stages of evaluation beginning from compilation of correlation matrix for measurement uncertainties till representation of the analysis results in the ENDF-6 format are described in details. Special attention is paid to restrictions (positive uncertainty) on covariation matrix of approximate parameters uncertainties generated within the method of least square fit which is derived from physical reasons. The requirements for source experimental data assuring satisfaction of the restrictions mentioned above are formulated. Correlation matrices of measurement uncertainties in particular should be also positively determined. Variants of modelling the positively determined correlation matrices of measurement uncertainties in a situation when their consequent calculation on the basis of experimental information is impossible are discussed. The technique described is used for creating the new generation of estimates of dosimetric reactions cross sections for the first version of the Russian dosimetric file (including nontrivial covariation information)

  8. Signal-to-noise ratio analysis and evaluation of the Hadamard imaging technique

    Science.gov (United States)

    Jobson, D. J.; Katzberg, S. J.; Spiers, R. B., Jr.

    1977-01-01

    The signal-to-noise ratio performance of the Hadamard imaging technique is analyzed and an experimental evaluation of a laboratory Hadamard imager is presented. A comparison between the performances of Hadamard and conventional imaging techniques shows that the Hadamard technique is superior only when the imaging objective lens is required to have an effective F (focus) number of about 2 or slower.

  9. [Intestinal lengthening techniques: an experimental model in dogs].

    Science.gov (United States)

    Garibay González, Francisco; Díaz Martínez, Daniel Alberto; Valencia Flores, Alejandro; González Hernández, Miguel Angel

    2005-01-01

    To compare two intestinal lengthening procedures in an experimental dog model. Intestinal lengthening is one of the methods for gastrointestinal reconstruction used for treatment of short bowel syndrome. The modification to the Bianchi's technique is an alternative. The modified technique decreases the number of anastomoses to a single one, thus reducing the risk of leaks and strictures. To our knowledge there is not any clinical or experimental report that studied both techniques, so we realized the present report. Twelve creole dogs were operated with the Bianchi technique for intestinal lengthening (group A) and other 12 creole dogs from the same race and weight were operated by the modified technique (Group B). Both groups were compared in relation to operating time, difficulties in technique, cost, intestinal lengthening and anastomoses diameter. There were no statistical difference in the anastomoses diameter (A = 9.0 mm vs. B = 8.5 mm, p = 0.3846). Operating time (142 min vs. 63 min) cost and technique difficulties were lower in group B (p anastomoses (of Group B) and intestinal segments had good blood supply and were patent along their full length. Bianchi technique and the modified technique offer two good reliable alternatives for the treatment of short bowel syndrome. The modified technique improved operating time, cost and technical issues.

  10. Guidance for Evaluating the Safety of Experimental Releases of Mosquitoes, Emphasizing Mark-Release-Recapture Techniques.

    Science.gov (United States)

    Benedict, Mark Q; Charlwood, J Derek; Harrington, Laura C; Lounibos, L Philip; Reisen, William K; Tabachnick, Walter J

    2018-01-01

    Experimental releases of mosquitoes are performed to understand characteristics of populations related to the biology, ability to transmit pathogens, and ultimately their control. In this article, we discuss considerations related to the safety of experimental releases of living mosquitoes, applying principles of good practice in vector biology that protect human health and comfort. We describe specific factors of experimental releases of mosquitoes that we believe are critical to inform institutional biosafety committees and similar review boards to which proposals to conduct mosquito release experiments have been submitted. In this study, "experimental releases" means those that do not significantly increase vector capacity or nuisance biting relative to the unperturbed natural baseline. This document specifically does not address releases of mosquitoes for ongoing control programs or trials of new control methods for which broader assessments of risk are required. It also does not address releases of transgenic or exotic (non-native) mosquito species, both of which require particular regulatory approval. Experimental releases may include females and males and evaluation must consider their effects based on the number released, their genotype and phenotype, the environment into which they are released, and postrelease collection activities. We consider whether increases of disease transmission and nuisance biting might result from proposed experimental releases against the backdrop of natural population size variation. We recommend that experimental releases be conducted in a manner that can be reasonably argued to have insignificant negative effects. Reviewers of proposals for experimental releases should expect applicants to provide such an argument based on evidence from similar studies and their planned activities. This document provides guidance for creating and evaluating such proposals.

  11. Evaluation of a simple Theileria annulata culture protocol from experimentally infected bovine whole blood

    Directory of Open Access Journals (Sweden)

    Gharbi M.

    2012-08-01

    Full Text Available We have evaluated a new simple technique using whole blood from experimentally infected cattle for the isolation and cultivation of Theileria annulata. The study was carried out on 20 Holstein-Frisian bovines that had been experimentally infected with a virulent lethal dose of Theileria annulata. This technique has been compared to the classical peripheral blood monocyte isolation with Ficoll carried out on 22 experimentally infected Holstein-Friesian calves. The effectiveness of the reference technique was estimated to 86.4%, whilst the effectiveness of the new technique was 100%. Moreover, this new technique leads to time and money saving estimated to € 3.06 per sample. It decreases the contamination risks by reducing the steps of sample manipulation.

  12. Endovascular stentectomy using the snare over stent-retriever (SOS technique: An experimental feasibility study.

    Directory of Open Access Journals (Sweden)

    Tareq Meyer

    Full Text Available Feasibility of endovascular stentectomy using a snare over stent-retriever (SOS technique was evaluated in a silicon flow model and an in vivo swine model. In vitro, stentectomy of different intracranial stents using the SOS technique was feasible in 22 out of 24 (92% retrieval maneuvers. In vivo, stentectomy was successful in 10 out of 10 procedures (100%. In one case self-limiting vasospasm was observed angiographically as a technique related complication in the animal model. Endovascular stentectomy using the SOS technique is feasible in an experimental setting and may be transferred to a clinical scenario.

  13. Evaluated experimental database on critical heat flux in WWER FA models

    International Nuclear Information System (INIS)

    Artamonov, S.; Sergeev, V.; Volkov, S.

    2015-01-01

    The paper presents the description of the evaluated experimental database on critical heat flux in WWER FA models of new designs. This database was developed on the basis of the experimental data obtained in the years of 2009-2012. In the course of its development, the database was reviewed in terms of completeness of the information about the experiments and its compliance with the requirements of Rostekhnadzor regulatory documents. The description of the experimental FA model characteristics and experimental conditions was specified. Besides, the experimental data were statistically processed with the aim to reject incorrect ones and the sets of experimental data on critical heat fluxes (CHF) were compared for different FA models. As a result, for the fi rst time, the evaluated database on CHF in FA models of new designs was developed, that was complemented with analysis functions, and its main purpose is to be used in the process of development, verification and upgrading of calculation techniques. The developed database incorporates the data of 4183 experimental conditions obtained in 53 WWER FA models of various designs. Keywords: WWER reactor, fuel assembly, CHF, evaluated experimental data, database, statistical analysis. (author)

  14. Physiotherapists use a small number of behaviour change techniques when promoting physical activity: A systematic review comparing experimental and observational studies.

    Science.gov (United States)

    Kunstler, Breanne E; Cook, Jill L; Freene, Nicole; Finch, Caroline F; Kemp, Joanne L; O'Halloran, Paul D; Gaida, James E

    2018-06-01

    Physiotherapists promote physical activity as part of their practice. This study reviewed the behaviour change techniques physiotherapists use when promoting physical activity in experimental and observational studies. Systematic review of experimental and observational studies. Twelve databases were searched using terms related to physiotherapy and physical activity. We included experimental studies evaluating the efficacy of physiotherapist-led physical activity interventions delivered to adults in clinic-based private practice and outpatient settings to individuals with, or at risk of, non-communicable diseases. Observational studies reporting the techniques physiotherapists use when promoting physical activity were also included. The behaviour change techniques used in all studies were identified using the Behaviour Change Technique Taxonomy. The behaviour change techniques appearing in efficacious and inefficacious experimental interventions were compared using a narrative approach. Twelve studies (nine experimental and three observational) were retained from the initial search yield of 4141. Risk of bias ranged from low to high. Physiotherapists used seven behaviour change techniques in the observational studies, compared to 30 behaviour change techniques in the experimental studies. Social support (unspecified) was the most frequently identified behaviour change technique across both settings. Efficacious experimental interventions used more behaviour change techniques (n=29) and functioned in more ways (n=6) than did inefficacious experimental interventions (behaviour change techniques=10 and functions=1). Physiotherapists use a small number of behaviour change techniques. Less behaviour change techniques were identified in observational studies compared to experimental studies, suggesting physiotherapists use less BCTs clinically than experimentally. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. Experimental techniques in nuclear and particle physics

    International Nuclear Information System (INIS)

    Tavernier, Stefaan

    2010-01-01

    The book is based on a course in nuclear and particle physics that the author has taught over many years to physics students, students in nuclear engineering and students in biomedical engineering. It provides the basic understanding that any student or researcher using such instruments and techniques should have about the subject. After an introduction to the structure of matter at the subatomic scale, it covers the experimental aspects of nuclear and particle physics. Ideally complementing a theoretically-oriented textbook on nuclear physics and/or particle physics, it introduces the reader to the different techniques used in nuclear and particle physics to accelerate particles and to measurement techniques (detectors) in nuclear and particle physics. The main subjects treated are: interactions of subatomic particles in matter; particle accelerators; basics of different types of detectors; and nuclear electronics. The book will be of interest to undergraduates, graduates and researchers in both particle and nuclear physics. For the physicists it is a good introduction to all experimental aspects of nuclear and particle physics. Nuclear engineers will appreciate the nuclear measurement techniques, while biomedical engineers can learn about measuring ionising radiation, the use of accelerators for radiotherapy. What's more, worked examples, end-of-chapter exercises, and appendices with key constants, properties and relationships supplement the textual material. (orig.)

  16. Phase equilibria basic principles, applications, experimental techniques

    CERN Document Server

    Reisman, Arnold

    2013-01-01

    Phase Equilibria: Basic Principles, Applications, Experimental Techniques presents an analytical treatment in the study of the theories and principles of phase equilibria. The book is organized to afford a deep and thorough understanding of such subjects as the method of species model systems; condensed phase-vapor phase equilibria and vapor transport reactions; zone refining techniques; and nonstoichiometry. Physicists, physical chemists, engineers, and materials scientists will find the book a good reference material.

  17. Clustering of experimental data and its application to nuclear data evaluation

    International Nuclear Information System (INIS)

    Abboud, A.; Rashed, R.; Ibrahim, M.

    1998-01-01

    A semi-automatic pre-processing technique has been proposed by Iwasaki to classify the experimental data for a reaction into one or a small number of large data groups, called main cluster (s), and to eliminate some data which deviates from the main body of the data. The classifying method is based on technique like pattern clustering in the information processing domain. Test of the data clustering formed reasonable main clusters for three activation cross-sections. This technique is a helpful tool in the neutron cross-section evaluation

  18. Research technique and experimental device for thermal conductivity measurements of refractory compounds

    International Nuclear Information System (INIS)

    Vishnevetskaya, I.A.; Petrov, V.A.

    1977-01-01

    Proposed is a new axial technique for determining thermal conductivity coefficient of solids at temperatures above 1000 deg C with the use of internal heating of specimens by passing electric current and with experimental determining the thermal flows on the lateral side of the working section of the specimen. This method is usable for investigating the thermal conductivity of materials whose surface radiation characteristics are unknown or unstable and for carrying out experiments not only in vacuum, but also in various atmospheres. The overall fiducial error of the results of the method is evaluated at 4-5 % within the range of temperatures between 1200 and 2300 K. A description of the experimental installation is given

  19. Oscillation experiments techniques in CEA Minerve experimental reactor

    Energy Technology Data Exchange (ETDEWEB)

    Antony, M.; Di-Salvo, J.; Pepino, A.; Bosq, J. C.; Bernard, D.; Leconte, P.; Hudelot, J. P.; Lyoussi, A. [CEA CADARACHE, DEN/DER/SPEx, 13108 Saint Paul-lez-Durance (France)

    2009-07-01

    This paper deals with experiments in the Minerve pool Zero Power Reactor. Minerve is mainly devoted to neutronics studies, in view to improve the calculation routes by reducing the uncertainties of the experimental databases for nuclides arising in plutonium and wastes management. Minerve experimental measurement programs are performed by using the oscillation technique. This experimental technique consists in a periodic insertion and extraction of samples containing the nuclide of interest in a well characterized neutron spectrum. The reactivity variation of the sample is compensated by a calibrated rotary automatic pilot using cadmium sectors. The normal accuracy for measurements of small-worth samples in Minerve by using such a technique is about 3% for absolute reactivity worth, including the uncertainties on the material balance and on the calibration step. Reactivity effects of less than 1.5 cent can be measured. The OSMOSE and the OCEAN programs have been carried out since 2005 and will last until 2011. These programs aim at improving, in different neutron spectra, the absorption cross sections of respectively a majority of the separated heavy nuclides from {sup 232}Th to {sup 245}Cm appearing during the reactor and the fuel cycle physics, and of current and future types of absorbers as Gd, Hf, Er, Dy and Eu. (authors)

  20. Clustering of experimental data and its application to nuclear data evaluation

    International Nuclear Information System (INIS)

    Abboud, A.; Rashed, R.; Ibrahim, M.

    1997-01-01

    A semi-automatic pre-processing technique has been proposed by Iwasaki to classify the experimental data for a reaction into one or a small number of large data groups, called main cluster(s), and to eliminate some data which deviate from the main body of the data. The classifying method is based on a technique like pattern clustering in the information processing domain. Test of the data clustering formed reasonable main clusters for three activation cross-sections. This technique is a helpful tool in the neutron cross-section evaluation. (author). 4 refs, 1 fig., 3 tabs

  1. Evaluation of CFD Turbulent Heating Prediction Techniques and Comparison With Hypersonic Experimental Data

    Science.gov (United States)

    Dilley, Arthur D.; McClinton, Charles R. (Technical Monitor)

    2001-01-01

    Results from a study to assess the accuracy of turbulent heating and skin friction prediction techniques for hypersonic applications are presented. The study uses the original and a modified Baldwin-Lomax turbulence model with a space marching code. Grid converged turbulent predictions using the wall damping formulation (original model) and local damping formulation (modified model) are compared with experimental data for several flat plates. The wall damping and local damping results are similar for hot wall conditions, but differ significantly for cold walls, i.e., T(sub w) / T(sub t) hypersonic vehicles. Based on the results of this study, it is recommended that the local damping formulation be used with the Baldwin-Lomax and Cebeci-Smith turbulence models in design and analysis of Hyper-X and future hypersonic vehicles.

  2. Experimental techniques for single cell and single molecule biomechanics

    International Nuclear Information System (INIS)

    Lim, C.T.; Zhou, E.H.; Li, A.; Vedula, S.R.K.; Fu, H.X.

    2006-01-01

    Stresses and strains that act on the human body can arise either from external physical forces or internal physiological environmental conditions. These biophysical interactions can occur not only at the musculoskeletal but also cellular and molecular levels and can determine the health and function of the human body. Here, we seek to investigate the structure-property-function relationship of cells and biomolecules so as to understand their important physiological functions as well as establish possible connections to human diseases. With the recent advancements in cell and molecular biology, biophysics and nanotechnology, several innovative and state-of-the-art experimental techniques and equipment have been developed to probe the structural and mechanical properties of biostructures from the micro- down to picoscale. Some of these experimental techniques include the optical or laser trap method, micropipette aspiration, step-pressure technique, atomic force microscopy and molecular force spectroscopy. In this article, we will review the basic principles and usage of these techniques to conduct single cell and single molecule biomechanics research

  3. Experimental Analysis of Temperature Differences During Implant Site Preparation: Continuous Drilling Technique Versus Intermittent Drilling Technique.

    Science.gov (United States)

    Di Fiore, Adolfo; Sivolella, Stefano; Stocco, Elena; Favero, Vittorio; Stellini, Edoardo

    2018-02-01

    Implant site preparation through drilling procedures may cause bone thermonecrosis. The aim of this in vitro study was to evaluate, using a thermal probe, overheating at implant sites during osteotomies through 2 different drilling methods (continuous drilling technique versus intermittent drilling technique) using irrigation at different temperatures. Five implant sites 13 mm in length were performed on 16 blocks (fresh bovine ribs), for a total of 80 implant sites. The PT-100 thermal probe was positioned 5 mm from each site. Two physiological refrigerant solutions were used: one at 23.7°C and one at 6.0°C. Four experimental groups were considered: group A (continuous drilling with physiological solution at 23.7°C), group B (intermittent drilling with physiological solution at 23.7°C), group C (continuous drilling with physiological solution at 6.0°C), and group D (intermittent drilling with physiological solution at 6.0°C). The Wilcoxon rank-sum test (2-tailed) was used to compare groups. While there was no difference between group A and group B (W = 86; P = .45), statistically significant differences were observed between experimental groups A and C (W = 0; P =.0001), B and D (W = 45; P =.0005), and C and D (W = 41; P = .003). Implant site preparation did not affect the overheating of the bone. Statistically significant differences were found with the refrigerant solutions. Using both irrigating solutions, bone temperature did not exceed 47°C.

  4. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  5. Numerical and experimental evaluation of masonry prisms by finite element method

    Directory of Open Access Journals (Sweden)

    C. F.R. SANTOS

    Full Text Available Abstract This work developed experimental tests and numerical models able to represent the mechanical behavior of prisms made of ordinary and high strength concrete blocks. Experimental tests of prisms were performed and a detailed micro-modeling strategy was adopted for numerical analysis. In this modeling technique, each material (block and mortar was represented by its own mechanical properties. The validation of numerical models was based on experimental results. It was found that the obtained numerical values of compressive strength and modulus of elasticity differ by 5% from the experimentally observed values. Moreover, mechanisms responsible for the rupture of the prisms were evaluated and compared to the behaviors observed in the tests and those described in the literature. Through experimental results it is possible to conclude that the numerical models have been able to represent both the mechanical properties and the mechanisms responsible for failure.

  6. Experimental data processing techniques by a personal computer

    International Nuclear Information System (INIS)

    Matsuura, Kiyokata; Tsuda, Kenzo; Abe, Yoshihiko; Kojima, Tsuyoshi; Nishikawa, Akira; Shimura, Hitoshi; Hyodo, Hiromi; Yamagishi, Shigeru.

    1989-01-01

    A personal computer (16-bit, about 1 MB memory) can be used at a low cost in the experimental data processing. This report surveys the important techniques on A/D and D/A conversion, display, store and transfer of the experimental data. It is also discussed the items to be considered in the software. Practical softwares programed BASIC and Assembler language are given as examples. Here, we present some techniques to get faster process in BASIC language and show that the system composed of BASIC and Assembler is useful in a practical experiment. The system performance such as processing speed and flexibility in setting operation condition will depend strongly on programming language. We have made test for processing speed by some typical programming languages; BASIC(interpreter), C, FORTRAN and Assembler. As for the calculation, FORTRAN has the best performance which is comparable to or better than Assembler even in the personal computer. (author)

  7. Experimental techniques in nuclear and particle physics

    CERN Document Server

    Tavernier, Stefaan

    2009-01-01

    The book is based on a course in nuclear and particle physics that the author has taught over many years to physics students, students in nuclear engineering and students in biomedical engineering. It provides the basic understanding that any student or researcher using such instruments and techniques should have about the subject. After an introduction to the structure of matter at the subatomic scale, it covers the experimental aspects of nuclear and particle physics. Ideally complementing a theoretically-oriented textbook on nuclear physics and/or particle physics, it introduces the reader to the different techniques used in nuclear and particle physics to accelerate particles and to measurement techniques (detectors) in nuclear and particle physics. The main subjects treated are: interactions of subatomic particles in matter; particle accelerators; basics of different types of detectors; and nuclear electronics. The book will be of interest to undergraduates, graduates and researchers in both particle and...

  8. Immunoperoxidase technique in experimental chronic chagasic myocarditis

    Directory of Open Access Journals (Sweden)

    M.d. Maria Celina Morales

    1987-04-01

    Full Text Available Chagas'disease has been described as the commonest form of chronic myocarditis. An immunologic pathogenesis has been discribed for this form of the disease. So far, no immunoperoxidase technique has been used for the detection of immunological deposits in chronic experimental Chagas'myocardiopathy. Forty-one Swiss mice, three months old were inoculated intraperitoneally with doses between 10 and 10(5 Tulahuen trypomastigotes. Mice were reinoculated one month after with doses between 10² and 10(5 and sacrificed at 6 (n=21 and 9 months (n=9 after the first inoculation. ECGs were recorded before sacrifice. Immunoperoxidase technique (peroxidase-antiperoxidase method, immunofluorescence (direct and indirect as well as histological studies were performed in myocardiums and skeletal muscles of the surviving animals. The most sensitive methods for detecting chronic chagasic infection were the routine histologic studies (73% and the ECGs 83% and 89% on 6 and 9 mo. post-infected mice, respectively. Myocardial involvement varied from interstitial mild focal lymphocyte infiltrates up to replacement of myocytes by loose connective tissue. Atrial myocardiums (21/23, 91% were more affected than ventricles (9/23, 39%. Typical chagasic nests were rarely found. Skeletal muscle involvement (11/18 and 7/9 varied from mild to extensive lymphocyte and plasmacell infiltrates, and necrotic fibers. The involved antigen were shown in skeletal muscles by the immunoperoxidase technique as diffusely arranged granular intracytoplasmatic deposit for both IgC and total immunoglobulins. The coincidence between this technique and histologic muscle lesions was 11/18 (61(% in 6 mo. and 6/8 (75% at 9 mo. post-infection. In heart, delicate granular deposits of total immunoglobulins were seen diffusely arranged within the ventricular myocytes; coincidence between immunoperoxidase technique anl histologic involvement increased from 36 to 66% in animals sacrifeced 6 and 9 mo. post

  9. Effective evaluation of privacy protection techniques in visible and thermal imagery

    Science.gov (United States)

    Nawaz, Tahir; Berg, Amanda; Ferryman, James; Ahlberg, Jörgen; Felsberg, Michael

    2017-09-01

    Privacy protection may be defined as replacing the original content in an image region with a (less intrusive) content having modified target appearance information to make it less recognizable by applying a privacy protection technique. Indeed, the development of privacy protection techniques also needs to be complemented with an established objective evaluation method to facilitate their assessment and comparison. Generally, existing evaluation methods rely on the use of subjective judgments or assume a specific target type in image data and use target detection and recognition accuracies to assess privacy protection. An annotation-free evaluation method that is neither subjective nor assumes a specific target type is proposed. It assesses two key aspects of privacy protection: "protection" and "utility." Protection is quantified as an appearance similarity, and utility is measured as a structural similarity between original and privacy-protected image regions. We performed an extensive experimentation using six challenging datasets (having 12 video sequences), including a new dataset (having six sequences) that contains visible and thermal imagery. The new dataset is made available online for the community. We demonstrate effectiveness of the proposed method by evaluating six image-based privacy protection techniques and also show comparisons of the proposed method over existing methods.

  10. Effect of an experimental zirconia-silica coating technique on micro tensile bond strength of zirconia in different priming conditions

    NARCIS (Netherlands)

    Chen, C.; Kleverlaan, C.J.; Feilzer, A.J.

    2012-01-01

    Objectives This study aimed to evaluate the adhesive properties of a MDP-containing resin cement to a colored zirconia ceramic, using an experimental zirconia-silica coating technique with different priming conditions. Methods 18 zirconia ceramic discs (Cercon base colored) were divided into two

  11. Immunoperoxidase technique in experimental chronic chagasic myocarditis

    OpenAIRE

    M.d. Maria Celina Morales; M.D. José Milei

    1987-01-01

    Chagas'disease has been described as the commonest form of chronic myocarditis. An immunologic pathogenesis has been discribed for this form of the disease. So far, no immunoperoxidase technique has been used for the detection of immunological deposits in chronic experimental Chagas'myocardiopathy. Forty-one Swiss mice, three months old were inoculated intraperitoneally with doses between 10 and 10(5) Tulahuen trypomastigotes. Mice were reinoculated one month after with doses between 10² and ...

  12. A TECHNIQUE OF EXPERIMENTAL INVESTIGATIONS OF LINEAR IMPULSE ELECTROMECHANICAL CONVERTERS

    Directory of Open Access Journals (Sweden)

    V.F. Bolyukh

    2017-04-01

    Full Text Available Purpose. Development of a technique of experimental studies linear pulse electromechanical converters parameters, which are used as shock-power devices and electromechanical accelerators, and comparing the experimental results with the calculated indices obtained using the mathematical model. Methodology. Method of experimental investigations of linear electromechanical converter is that the electrical parameters are recorded simultaneously (inductor winding current and mechanical parameters characterizing the power and speed indicators of the joke with actuator. Power indicators are primarily important for shock-power devices, and high velocity - for electromechanical accelerators. Power indices were investigated using piezoelectric sensors, a system of strain sensors, pressure pulsation sensor and high-speed videorecording. Velocity indicators were investigated using a resistive movement sensor which allows to record character of the armature movement with actuating element in each moment. Results. The technique of experimental research, which is the simultaneous recording of electrical and mechanical power and velocity parameters of the linear electromechanical converter pulse, is developed. In the converter as a shock-power device power indicators are recorded using a piezoelectric transducer, strain sensors system, pressure pulsation sensor and high-speed video. The parameters of the inductor winding current pulse, the time lag of mechanical processes in relation to the time of occurrence of the inductor winding current, the average speed of the joke, the magnitude and momentum of electrodynamics forces acting on the plate strikes are experimentally determined. In the converter as an electromechanical accelerator velocity performance recorded using resistive displacement sensors. It is shown that electromechanical converter processes have complex spatial-temporal character. The experimental results are in good agreement with the calculated

  13. Computer technique for evaluating collimator performance

    International Nuclear Information System (INIS)

    Rollo, F.D.

    1975-01-01

    A computer program has been developed to theoretically evaluate the overall performance of collimators used with radioisotope scanners and γ cameras. The first step of the program involves the determination of the line spread function (LSF) and geometrical efficiency from the fundamental parameters of the collimator being evaluated. The working equations can be applied to any plane of interest. The resulting LSF is applied to subroutine computer programs which compute corresponding modulation transfer function and contrast efficiency functions. The latter function is then combined with appropriate geometrical efficiency data to determine the performance index function. The overall computer program allows one to predict from the physical parameters of the collimator alone how well the collimator will reproduce various sized spherical voids of activity in the image plane. The collimator performance program can be used to compare the performance of various collimator types, to study the effects of source depth on collimator performance, and to assist in the design of collimators. The theory of the collimator performance equation is discussed, a comparison between the experimental and theoretical LSF values is made, and examples of the application of the technique are presented

  14. Remote welding and cutting techniques for fusion experimental reactors

    International Nuclear Information System (INIS)

    Onozuka, M.; Ishide, T.; Oda, Y.; Nagaoka, E.; Ue, K.; Kamei, H.

    1995-01-01

    Experimental investigation of the YAG laser cutting/welding and plasma gouging techniques has been conducted to examine their suitability for remote maintenance systems in future fusion experimental reactors. Using a hybrid beam coupling system, two laser beams of 500W and 740W powers were successfully combined to provide a 1,240W beam power. The combined laser was transmitted through the optical fiber for cutting and welding. The transmission loss for the beams is in the range of 13% to 14%, which is low. As for plasma gouging, the shallow gouging made a groove measuring 10 mm in width and 4 mm in depth on the stainless steel plates at a traversing speed of 75 cm/min, while the deep gouging made a groove of 12 mm in width and 7.5 mm in depth at a traversing speed of 50 cm/min. In addition, it was found that the shallow gouging did not leave byproducts from the material, providing a clean surface. Based on the findings, it is shown that the YAG laser cutting/welding and plasma gouging techniques can be us3ed for remote welding and cutting in future fusion experimental reactors

  15. Remote welding and cutting techniques for fusion experimental reactors

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M.; Ishide, T.; Oda, Y.; Nagaoka, E.; Ue, K.; Kamei, H. [Mitsubishi Heavy Industries, Ltd., Yokohama (Japan)

    1995-12-31

    Experimental investigation of the YAG laser cutting/welding and plasma gouging techniques has been conducted to examine their suitability for remote maintenance systems in future fusion experimental reactors. Using a hybrid beam coupling system, two laser beams of 500W and 740W powers were successfully combined to provide a 1,240W beam power. The combined laser was transmitted through the optical fiber for cutting and welding. The transmission loss for the beams is in the range of 13% to 14%, which is low. As for plasma gouging, the shallow gouging made a groove measuring 10 mm in width and 4 mm in depth on the stainless steel plates at a traversing speed of 75 cm/min, while the deep gouging made a groove of 12 mm in width and 7.5 mm in depth at a traversing speed of 50 cm/min. In addition, it was found that the shallow gouging did not leave byproducts from the material, providing a clean surface. Based on the findings, it is shown that the YAG laser cutting/welding and plasma gouging techniques can be us3ed for remote welding and cutting in future fusion experimental reactors.

  16. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  17. Experimental Study on Damage Detection in Timber Specimens Based on an Electromechanical Impedance Technique and RMSD-Based Mahalanobis Distance

    Directory of Open Access Journals (Sweden)

    Dansheng Wang

    2016-10-01

    Full Text Available In the electromechanical impedance (EMI method, the PZT patch performs the functions of both sensor and exciter. Due to the high frequency actuation and non-model based characteristics, the EMI method can be utilized to detect incipient structural damage. In recent years EMI techniques have been widely applied to monitor the health status of concrete and steel materials, however, studies on application to timber are limited. This paper will explore the feasibility of using the EMI technique for damage detection in timber specimens. In addition, the conventional damage index, namely root mean square deviation (RMSD is employed to evaluate the level of damage. On that basis, a new damage index, Mahalanobis distance based on RMSD, is proposed to evaluate the damage severity of timber specimens. Experimental studies are implemented to detect notch and hole damage in the timber specimens. Experimental results verify the availability and robustness of the proposed damage index and its superiority over the RMSD indexes.

  18. Inverse kinetics technique for reactor shutdown measurement: an experimental assessment. [AGR

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, T. A.; McDonald, D.

    1975-09-15

    It is proposed to use the Inverse Kinetics Technique to measure the subcritical reactivity as a function of time during the testing of the nitrogen injection systems on AGRs. A description is given of an experimental assessment of the technique by investigating known transients created by control rod movements on a small experimental reactor, (2m high, 1m radius). Spatial effects were observed close to the moving rods but otherwise derived reactivities were independent of detector position and agreed well with the existing calibrations. This prompted the suggestion that data from installed reactor instrumentation could be used to calibrate CAGR control rods.

  19. Comparison of experimental techniques for characterization of through-thickness texture variations

    DEFF Research Database (Denmark)

    Mishin, Oleg; Lauridsen, E.M.; Krieger Lassen, N.C.

    1999-01-01

    For the investigation of through-thickness texture gradients, a number of layers in rolled plates and sheets are inspected. Crystallographic textures in different layers can be characterized using several techniques. In the present work, traditional low-energy X-ray diffraction, the electron...... backscattering pattern technique in the scanning electron microscope and a novel technique which involves high energy synchrotron radiation are used for characterization of through-thickness texture variations in commercial purity cold-rolled aluminium. Important experimental aspects of these three techniques...

  20. Advanced experimental and numerical techniques for cavitation erosion prediction

    CERN Document Server

    Chahine, Georges; Franc, Jean-Pierre; Karimi, Ayat

    2014-01-01

    This book provides a comprehensive treatment of the cavitation erosion phenomenon and state-of-the-art research in the field. It is divided into two parts. Part 1 consists of seven chapters, offering a wide range of computational and experimental approaches to cavitation erosion. It includes a general introduction to cavitation and cavitation erosion, a detailed description of facilities and measurement techniques commonly used in cavitation erosion studies, an extensive presentation of various stages of cavitation damage (including incubation and mass loss), and insights into the contribution of computational methods to the analysis of both fluid and material behavior. The proposed approach is based on a detailed description of impact loads generated by collapsing cavitation bubbles and a physical analysis of the material response to these loads. Part 2 is devoted to a selection of nine papers presented at the International Workshop on Advanced Experimental and Numerical Techniques for Cavitation Erosion (Gr...

  1. Experimental and mathematical simulation techniques for determining an in-situ response testing method for neutron sensors used in reactor power plant protection systems

    International Nuclear Information System (INIS)

    Behbahani, A.

    1983-01-01

    An analytical neutron sensor response model and methods for transient response measurements of neutron sensors (compensated ionization chamber), including possible in-situ techniques have been developed and evaluated to meet the provisions of Draft Standard ISA Sd67.06, IEEE 338-1977, and NRC Guide 1.118. One in-situ method requires the perturbation of the high voltage detector (sensor) power supply and measurement of the sensor response. The response to a perturbation of the power supply is related to the response of the sensor to a transient change in neutron flux. Random signal analysis is another in-situ technique to monitor the neutron sensor response. In this method the power spectrum of the inherent fluctuations from the neutron sensor output (current in CIC) are measured and evaluated. Transient response techniques (including in-situ methods) are experimentally and analytically evaluated to identify the mechanisms which may cause degradation in the response of the neutron sensors. The objective of the experimental evaluation was to correlate the measured response time using transient radiation flux changes and power supply perturbation. The objective of the analytical model of the different sensor response was to predict response time and degradation mechanisms

  2. Radiologic techniques in evaluation endocrine disorders

    International Nuclear Information System (INIS)

    Martino, C.R.; Schultz, C.L.; Butler, H.E.; Haaga, J.R.

    1988-01-01

    This paper discusses evaluation of normal and diseased endocrine organs that has been facilitated by the development of new radiologic-imaging techniques including nuclear medicine, ultrasound, computed tomography, and magnetic resonance imaging. With improvement in resolution and tissue contrast, abnormalities as small as 5 mm can now be imaged with these modalities. Endocrinologists and clinicians involved in the evaluation and diagnosis of patients with endocrine diseases can be substantially aided by a proper radiologic workup. The authors describe and illustrate various radiologic techniques that are useful for evaluating thyroid and parathyroid derangements

  3. Method for automatically evaluating a transition from a batch manufacturing technique to a lean manufacturing technique

    Science.gov (United States)

    Ivezic, Nenad; Potok, Thomas E.

    2003-09-30

    A method for automatically evaluating a manufacturing technique comprises the steps of: receiving from a user manufacturing process step parameters characterizing a manufacturing process; accepting from the user a selection for an analysis of a particular lean manufacturing technique; automatically compiling process step data for each process step in the manufacturing process; automatically calculating process metrics from a summation of the compiled process step data for each process step; and, presenting the automatically calculated process metrics to the user. A method for evaluating a transition from a batch manufacturing technique to a lean manufacturing technique can comprise the steps of: collecting manufacturing process step characterization parameters; selecting a lean manufacturing technique for analysis; communicating the selected lean manufacturing technique and the manufacturing process step characterization parameters to an automatic manufacturing technique evaluation engine having a mathematical model for generating manufacturing technique evaluation data; and, using the lean manufacturing technique evaluation data to determine whether to transition from an existing manufacturing technique to the selected lean manufacturing technique.

  4. Application and evaluation of the artificial tritium tagging of moisture soil technique in hydrogeological research in Brazil

    International Nuclear Information System (INIS)

    Castro Rubio Poli, D. de; Kimmelmann e Silva, A.A.

    1990-08-01

    In this work, we apply and make an evaluation the artificial tritium tagging technique of moisture in many kinds of soils for the determination of rainfall infiltration in unsaturated zone. The purpose of this work is the determination of ground water recharge in order to assist evaluating sites for radioactive waste disposal and water resources. From the experimental results obtained, we can conclude that the use of artificial tritium tagging method is an accurate, useful and probably the best available technique to determine ground water recharge. (author) [pt

  5. Nonlocal Regularized Algebraic Reconstruction Techniques for MRI: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Xin Li

    2013-01-01

    Full Text Available We attempt to revitalize researchers' interest in algebraic reconstruction techniques (ART by expanding their capabilities and demonstrating their potential in speeding up the process of MRI acquisition. Using a continuous-to-discrete model, we experimentally study the application of ART into MRI reconstruction which unifies previous nonuniform-fast-Fourier-transform- (NUFFT- based and gridding-based approaches. Under the framework of ART, we advocate the use of nonlocal regularization techniques which are leveraged from our previous research on modeling photographic images. It is experimentally shown that nonlocal regularization ART (NR-ART can often outperform their local counterparts in terms of both subjective and objective qualities of reconstructed images. On one real-world k-space data set, we find that nonlocal regularization can achieve satisfactory reconstruction from as few as one-third of samples. We also address an issue related to image reconstruction from real-world k-space data but overlooked in the open literature: the consistency of reconstructed images across different resolutions. A resolution-consistent extension of NR-ART is developed and shown to effectively suppress the artifacts arising from frequency extrapolation. Both source codes and experimental results of this work are made fully reproducible.

  6. A novel experimental technique of nuclear lifetime measurements

    International Nuclear Information System (INIS)

    Yuminov, O.A.; D'Arrigo, A.; Giardina, G.; Taccone, A.; Vannini, G.; Moroni, A.; Ricci, R.A.; Vannucci, L.

    1995-01-01

    In the present paper a new experimental method to measure nuclear reaction time in the 10 -15 -10 -10 s region is presented. Measurements of the lifetimes of low-lying and long-lived states of 19 F and 20 Ne decaying via α-channel were carried out with the aim of checking the feasibility of the method. The results obtained in this way are compared with the lifetimes known from different techniques. ((orig.))

  7. An experimental technique to measure the capillary waves in electrified microjets

    Directory of Open Access Journals (Sweden)

    Rebollo-Muñoz Noelia

    2012-04-01

    Full Text Available Backlight optical imaging is an experimental technique with an enormous potential in microfluidics to study very varied fluid configurations and phenomena. In this paper, we show the capability of this technique to precisely characterize the capillary waves growing in electrified microjets. For this purpose, images of electrified liquid jets formed by electrospray were acquired and processed using a sub-pixel resolution technique. Our results reflect the validity and usefulness of optical imaging for this type of application.

  8. Comparative evaluation of scatter correction techniques in 3D positron emission tomography

    CERN Document Server

    Zaidi, H

    2000-01-01

    Much research and development has been concentrated on the scatter compensation required for quantitative 3D PET. Increasingly sophisticated scatter correction procedures are under investigation, particularly those based on accurate scatter models, and iterative reconstruction-based scatter compensation approaches. The main difference among the correction methods is the way in which the scatter component in the selected energy window is estimated. Monte Carlo methods give further insight and might in themselves offer a possible correction procedure. Methods: Five scatter correction methods are compared in this paper where applicable. The dual-energy window (DEW) technique, the convolution-subtraction (CVS) method, two variants of the Monte Carlo-based scatter correction technique (MCBSC1 and MCBSC2) and our newly developed statistical reconstruction-based scatter correction (SRBSC) method. These scatter correction techniques are evaluated using Monte Carlo simulation studies, experimental phantom measurements...

  9. Is There a Purchase Limit on Regional Growth? A Quasi-experimental Evaluation of Investment Grants Using Matching Techniques

    DEFF Research Database (Denmark)

    Mitze, Timo Friedel; Paloyo, Alfredo R.; Alecke, Björn

    2015-01-01

    In this article, we apply recent advances in quasi-experimental estimation methods to analyze the effectiveness of Germany’s large-scale regional policy instrument, the joint Federal Government/State Programme “Gemeinschaftsaufgabe Verbesserung der regionalen Wirtschaftsstruktur” (GRW), which is ...... of matching techniques in regional data settings. Overall, however, the matching approach can still be considered of great value for regional policy analysis and should be the subject of future research efforts in the field of empirical regional science.......In this article, we apply recent advances in quasi-experimental estimation methods to analyze the effectiveness of Germany’s large-scale regional policy instrument, the joint Federal Government/State Programme “Gemeinschaftsaufgabe Verbesserung der regionalen Wirtschaftsstruktur” (GRW), which...... is a means to foster labor-productivity growth in lagging regions. In particular, adopting binary and generalized propensity-score matching methods, our results indicate that the GRW can be generally considered effective. However, we find evidence for a nonlinear relationship between GRW funding and regional...

  10. Experimental verifications of a structural damage identification technique using reduced order finite-element model

    Science.gov (United States)

    Li, Rui; Zhou, Li; Yang, Jann N.

    2010-04-01

    An objective of the structural health monitoring system is to identify the state of the structure and to detect the damage when it occurs. Analysis techniques for the damage identification of structures, based on vibration data measured from sensors, have received considerable attention. Recently, a new damage tracking technique, referred to as the adaptive quadratic sum-square error (AQSSE) technique, has been proposed, and simulation studies demonstrated that the AQSSE technique is quite effective in identifying structural damages. In this paper, the adaptive quadratic sumsquare error (AQSSE) along with the reduced-order finite-element method is proposed to identify the damages of complex structures. Experimental tests were conducted to verify the capability of the proposed damage detection approach. A series of experimental tests were performed using a scaled cantilever beam subject to the white noise and sinusoidal excitations. The capability of the proposed reduced-order finite-element based adaptive quadratic sum-square error (AQSSE) method in detecting the structural damage is demonstrated by the experimental results.

  11. An experimental investigation of heat transfer enhancement in minichannel: Combination of nanofluid and micro fin structure techniques

    DEFF Research Database (Denmark)

    Zhang, Ji; Diao, Yanhua; Zhao, Yaohua

    2017-01-01

    This work experimentally studied the single-phase heat transfer and pressure drop characteristics by using two heat transfer enhancement techniques (micro fin structure and nanofluids) in multiport minichannel flat tube (MMFT). MMFT consisted of numerous parallel rectangular minichannels...... and is widely used in industry as the heat transfer unit of a heat exchanger. Firstly, the enhanced heat transfer performances by individually using one enhancement technique were investigated by testing Nusselt number, friction factor and performance evaluation criterion (PEC). In this section, five MMFTs...... with different micro fin numbers (N = 0, 1, 2, 3 and 4) and nanofluids with three volume concentrations (φ = 0.005%, 0.01% and 0.1%) were used as test sections and working fluids respectively. Secondly, the experiments using two combined enhancement technique were performed. By using conjunctively two...

  12. A critical evaluation of multistage equilibration technique for preconcentration by ion-exchange

    International Nuclear Information System (INIS)

    Iyer, R.K.

    1994-01-01

    Capabilities of the method of preconcentration of heavy metal ions from aqueous samples by Chelex 100 using a successive equilibration technique has been evaluated. The process of successive equilibrations may be looked upon in one of the two ways: one of equilibrating a given amount of resin with n successive aliquots so that sample size increases n-fold. Alternatively one may consider this as dividing a large-sized sample into n equal aliquots and carrying out the equilibrations with a smaller amount of resin maintaining the v/m ratio. Expressions have been derived for overall recovery, percentage recovery and decontamination factor for the successive equilibration technique. The validity of the expressions has been checked with experimental data. The values for recovery and decontamination factor have been compared with those for a single equilibration using the whole sample. Finally the factors which affect the value of recovery have been examined and their effect on the recovery has been evaluated. (author). 12 refs., 4 tabs., 1 appendix

  13. Experimental techniques for the consolidation of the neutron spectrum

    International Nuclear Information System (INIS)

    Chiaraviglio, N.; Bazzana, S.

    2013-01-01

    Unfolding techniques are widely known but their use is not widespread due to their complexity. Such procedure consists in the adjustment of calculated quantities to experimental results by the modification of the neutron spectrum, getting correction factors for the calculated quantities. In this work we describe the general procedure that must be executed for a neutron spectrum unfolding. (author) [es

  14. Evaluation of New Ultrasound Techniques for Clinical Imaging in selected Liver and Vascular Applications

    DEFF Research Database (Denmark)

    Brandt, Andreas Hjelm

    blinded to information about the technique, which B-mode images they preferred, as well as detection of pathology. Evaluation showed that the techniques were preferred equally and tumor could be detected equally well. Study II deals with the ability of vector flow imaging (VFI) to monitor patients......This Ph.D. project is based on a longstanding collaboration between physicists and engineers from the Center of Fast Ultrasound Imaging (CFU) at the Technical University of Denmark and medical doctors from the department of Radiology at Rigshospitalet. The intent of this cooperation is to validate...... new ultrasonic methods for future clinical use. Study I compares two B-mode ultrasound methods: the new experimental technique Synthetic Aperture Sequential Beamforming combined with Tissue Harmonic Imaging (SASB-THI), and a conventional technique combined with THI. While SASB reduces the amount...

  15. Experimental determination of liquidus of Fe-Zr by spot technique

    International Nuclear Information System (INIS)

    Ramakrishna, P.; Samanta, B.; Balakrishnan, S.

    2016-01-01

    Metallic fuel alloy for fast reactor mainly consist of U-Pu-Zr housed in T91 clad. Study of thermophysical properties of fuel element and cladding material is vital for the fuel designer to optimize the design feature and predict the fuel behavior under reactor operating conditions.To understand the fuel-clad interaction the phase diagram study of Fe-Zr system is very important since future reactors use U-Pu-Zr alloy as fuel and stainless steel as clad. The eutectic temperature in Fe-Zr alloy system has been established experimentally by various methods. Information on the liquidus temperatures of Fe-Zr is scanty in the literature excepting a very few experimental measurements. Hence measurement of liquidus temperatures is very essential to establish the phase diagram. Present work concentrates more on the generation of liquidus data of Fe-Zr binary alloy system by Spot-technique. This is one among the advanced techniques for measuring the solid-liquid phase transition temperatures. (author)

  16. Phase behavior of multicomponent membranes: Experimental and computational techniques

    DEFF Research Database (Denmark)

    Bagatolli, Luis; Kumar, P.B. Sunil

    2009-01-01

    Recent developments in biology seems to indicate that the Fluid Mosaic model of membrane proposed by Singer and Nicolson, with lipid bilayer functioning only as medium to support protein machinery, may be too simple to be realistic. Many protein functions are now known to depend on the compositio....... This review includes basic foundations on membrane model systems and experimental approaches applied in the membrane research area, stressing on recent advances in the experimental and computational techniques....... membranes. Current increase in interest in the domain formation in multicomponent membranes also stems from the experiments demonstrating liquid ordered-liquid disordered coexistence in mixtures of lipids and cholesterol and the success of several computational models in predicting their behavior...

  17. Experimental initial partial polymerization method for Fuji II placement evaluated for microleakage with/without Fuji Coat.

    Science.gov (United States)

    Chen, J W; Fletcher, B; Roggenkamp, C L

    2013-01-01

    This laboratory study evaluated an experimental 1-second initial partial polymerization (IPP) technique using Fuji II LC vs the manufacturer's standard placement (control), both with and without Fuji Coat, relative to microleakage. Class V restorative preparations were placed on the buccal and lingual aspects of 30 permanent, caries-free and restoration-free, third molar teeth. Fuji II LC restorations were placed either following manufacturer-specified guidelines or IPP for 1 second prior to contouring and full light curing. Half of the restorations were placed using the IPP experimental technique and half of the teeth were finished using Fuji Coat LC. Following thermocycling, specimens were sectioned and dye penetration was measured. SPSS 16 was used for statistical analysis (pCoat LC results in further diminished microleakage.

  18. Experimental techniques for the study of radiation damage in metals and alloys

    International Nuclear Information System (INIS)

    Novion, C.H. de.

    1983-06-01

    In this review, one presents the main experimental techniques used to study point defects and defect clusters introduced by irradiation in metals and alloys; emphasis will be put on some recent techniques. In particular, the studies allowing to analyse the very small agglomerates of point defects (Huang and small angle scattering, positron annihilation, electron microscopy) will be compared [fr

  19. Preparation of uranium targets and application of analytical techniques for its evaluation

    International Nuclear Information System (INIS)

    Luna Z, D.

    1994-01-01

    The objective of this work is to establish a method to produce uranium targets. The method selected for this purpose was the molecular plating. The first part of this work is devoted to the proper selection of an analytical technique to evaluate the different steps of the molecular plating method. Neutron Activation Analysis was chosen, because its high sensitivity and can be adapted easily to follow the whole procedure. The second part presents the experimental procedure and the study of the different parameters involved in the molecular plating and the evaluation of its uniformity was made using plastic track detectors. The results obtained are presented and a procedure is suggested to produce uranium targets. (Author)

  20. A Study on Nondestructive Technique Using Laser Technique for Evaluation of Carbon fiber Reinforced Plastic

    International Nuclear Information System (INIS)

    Choi, Sang Woo; Lee, Joon Hyun; Seo, Kyeong Cheol; Byun, Joon Hyung

    2005-01-01

    Fiber reinforced plastic material should be inspected in fabrication process in order to enhance quality by prevent defects such as delamination and void. Generally, ultrasonic technique is widely used to evaluate FRP. In conventional ultrasonic techniques, transducer should be contacted on FRP. However, conventional contacting method could not be applied in fabrication process and novel non-contact evaluating technique was required. Laser-based ultrasonic technique was tried to evaluate CFRP plate. Laser-based ultrasonic waves propagated on CFRP were received with various transducers such as accelerometer and AE sensor in order to evaluate the properties of waves due to the variation of frequency. Velocities of laser-based ultrasonic waves were evaluated for various fiber orientation. In addition, laser interferometry was used to receive ultrasonic wave in CFRP and frequency was analysed

  1. Modifying Formative Evaluation Techniques For Distance Education Class Evaluation

    Directory of Open Access Journals (Sweden)

    Scott L. WALKER

    2005-10-01

    Full Text Available Modifying Formative Evaluation Techniques For Distance Education Class Evaluation Assistant Professor Scott L. WALKERDepartment of GeographyTexas State UniversitySan Marcos, USA ABSTRACTPost-secondary classes are usually followed by mandatory summative evaluations, yet changes in teaching and course structure cannot be made with summative evaluations. Formative evaluations in online education can result in candid responses from students if a third-party facilitator is involved in the process. This paper presents a method for conducting formative evaluation in an online class by utilizing the assistance of a colleague. Results of one such evaluation are presented, as are its advantages and disadvantages.

  2. An Experimental Evaluation of the Effect of Hole Fabrication/Treatment Techniques on Residual Strength and Fatigue Life of Polycarbonate Specimens with Holes

    Science.gov (United States)

    1993-08-01

    34The Effect of Dimpling on the Fatigue Strength of Loaded Holes in a Corrosive Environment," Experimental Techniques, Vol. 9, September 1985, 33-36. 34...Expansion on the Fatigue Behavior of 7079-T652 Alluminium [sic] Alloy," NLR TR 74016 U, National Aerospace Laboratory (NLR), Amsterdam, The

  3. Research on evaluation techniques for immersive multimedia

    Science.gov (United States)

    Hashim, Aslinda M.; Romli, Fakaruddin Fahmi; Zainal Osman, Zosipha

    2013-03-01

    Nowadays Immersive Multimedia covers most usage in tremendous ways, such as healthcare/surgery, military, architecture, art, entertainment, education, business, media, sport, rehabilitation/treatment and training areas. Moreover, the significant of Immersive Multimedia to directly meet the end-users, clients and customers needs for a diversity of feature and purpose is the assembly of multiple elements that drive effective Immersive Multimedia system design, so evaluation techniques is crucial for Immersive Multimedia environments. A brief general idea of virtual environment (VE) context and `realism' concept that formulate the Immersive Multimedia environments is then provided. This is followed by a concise summary of the elements of VE assessment technique that is applied in Immersive Multimedia system design, which outlines the classification space for Immersive Multimedia environments evaluation techniques and gives an overview of the types of results reported. A particular focus is placed on the implications of the Immersive Multimedia environments evaluation techniques in relation to the elements of VE assessment technique, which is the primary purpose of producing this research. The paper will then conclude with an extensive overview of the recommendations emanating from the research.

  4. Techniques for Improving the Accuracy of 802.11 WLAN-Based Networking Experimentation

    Directory of Open Access Journals (Sweden)

    Portoles-Comeras Marc

    2010-01-01

    Full Text Available Wireless networking experimentation research has become highly popular due to both the frequent mismatch between theory and practice and the widespread availability of low-cost WLAN cards. However, current WLAN solutions present a series of performance issues, sometimes difficult to predict in advance, that may compromise the validity of the results gathered. This paper surveys recent literature dealing with such issues and draws attention on the negative results of starting experimental research without properly understanding the tools that are going to be used. Furthermore, the paper details how a conscious assessment strategy can prevent placing wrong assumptions on the hardware. Indeed, there are numerous techniques that have been described throughout the literature that can be used to obtain a deeper understanding of the solutions that have been adopted. The paper surveys these techniques and classifies them in order to provide a handful reference for building experimental setups from which accurate measurements may be obtained.

  5. Development of a Nondestructive Evaluation Technique for Degraded Thermal Barrier Coatings Using Microwave

    Science.gov (United States)

    Sayar, M.; Ogawa, K.; Shoji, T.

    2008-02-01

    Thermal barrier coatings have been widely used in gas turbine engines in order to protect substrate metal alloy against high temperature and to enhance turbine efficiency. Currently, there are no reliable nondestructive techniques available to monitor TBC integrity over lifetime of the coating. Hence, to detect top coating (TC) and TGO thicknesses, a microwave nondestructive technique that utilizes a rectangular waveguide was developed. The phase of the reflection coefficient at the interface of TC and waveguide varies for different TGO and TC thicknesses. Therefore, measuring the phase of the reflection coefficient enables us to accurately calculate these thicknesses. Finally, a theoretical analysis was used to evaluate the reliability of the experimental results.

  6. Application and evaluation of the artificial tritium tagging of moisture soil technique in hydrogeological research in Brazil

    International Nuclear Information System (INIS)

    Castro Rubio Poli, D. de.

    1989-01-01

    In this work, we apply and make an evaluation of the technique of artificial tritium tagging of moisture in many kinds of soils for the determination of rainfall infiltration in unsaturated zone. The purpose of this work is the determination of ground water recharge in order to assist in evaluation of sites for the disposal of radioactive wastes and also to assist in the evaluation of water resources. With this thesis, we intend to present a new choice for the measuring of local ground water recharge rate, due to availability of artificial tritium. From the experimental results obtained, we can conclude that the use of artificial tritium tagging method is an accurate, useful and probably the best available technique to determine ground water recharge. (author)

  7. Evaluation of EMG processing techniques using Information Theory.

    Science.gov (United States)

    Farfán, Fernando D; Politti, Julio C; Felice, Carmelo J

    2010-11-12

    Electromyographic signals can be used in biomedical engineering and/or rehabilitation field, as potential sources of control for prosthetics and orthotics. In such applications, digital processing techniques are necessary to follow efficient and effectively the changes in the physiological characteristics produced by a muscular contraction. In this paper, two methods based on information theory are proposed to evaluate the processing techniques. These methods determine the amount of information that a processing technique is able to extract from EMG signals. The processing techniques evaluated with these methods were: absolute mean value (AMV), RMS values, variance values (VAR) and difference absolute mean value (DAMV). EMG signals from the middle deltoid during abduction and adduction movement of the arm in the scapular plane was registered, for static and dynamic contractions. The optimal window length (segmentation), abduction and adduction movements and inter-electrode distance were also analyzed. Using the optimal segmentation (200 ms and 300 ms in static and dynamic contractions, respectively) the best processing techniques were: RMS, AMV and VAR in static contractions, and only the RMS in dynamic contractions. Using the RMS of EMG signal, variations in the amount of information between the abduction and adduction movements were observed. Although the evaluation methods proposed here were applied to standard processing techniques, these methods can also be considered as alternatives tools to evaluate new processing techniques in different areas of electrophysiology.

  8. Data Collection and Analysis Techniques for Evaluating the Perceptual Qualities of Auditory Stimuli

    Energy Technology Data Exchange (ETDEWEB)

    Bonebright, T.L.; Caudell, T.P.; Goldsmith, T.E.; Miner, N.E.

    1998-11-17

    This paper describes a general methodological framework for evaluating the perceptual properties of auditory stimuli. The framework provides analysis techniques that can ensure the effective use of sound for a variety of applications including virtual reality and data sonification systems. Specifically, we discuss data collection techniques for the perceptual qualities of single auditory stimuli including identification tasks, context-based ratings, and attribute ratings. In addition, we present methods for comparing auditory stimuli, such as discrimination tasks, similarity ratings, and sorting tasks. Finally, we discuss statistical techniques that focus on the perceptual relations among stimuli, such as Multidimensional Scaling (MDS) and Pathfinder Analysis. These methods are presented as a starting point for an organized and systematic approach for non-experts in perceptual experimental methods, rather than as a complete manual for performing the statistical techniques and data collection methods. It is our hope that this paper will help foster further interdisciplinary collaboration among perceptual researchers, designers, engineers, and others in the development of effective auditory displays.

  9. Experimental and theoretical contributions to X-ray phase-contrast techniques for medical imaging

    International Nuclear Information System (INIS)

    Diemoz, P.C.

    2011-01-01

    Several X-ray phase-contrast techniques have recently been developed. Unlike conventional X-ray methods, which measure the absorption properties of the tissues, these techniques derive contrast also from the modulation of the phase produced by the sample. Since the phase shift can be significant even for small details characterized by weak or absent absorption, the achievable image contrast can be greatly increased, notably for the soft biological tissues. These methods are therefore very promising for applications in the medical domain. The aim of this work is to contribute to a deeper understanding of these techniques, in particular propagation-based imaging (PBI), analyzer-based imaging (ABI) and grating interferometry (GIFM), and to study their potential and the best practical implementation for medical imaging applications. An important part of this work is dedicated to the use of mathematical algorithms for the extraction, from the acquired images, of quantitative sample information (the absorption, refraction and scattering sample properties). In particular, five among the most known algorithms based on the geometrical optics approximation have been theoretically analysed and experimentally compared, in planar and tomographic modalities, by using geometrical phantoms and human bone-cartilage and breast samples. A semi-quantitative method for the acquisition and reconstruction of tomographic images in the ABI and GIFM techniques has also been proposed. The validity conditions are analyzed in detail and the method, enabling a considerable simplification of the imaging procedure, has been experimentally checked on phantoms and human samples. Finally, a theoretical and experimental comparison of the PBI, ABI and GIFM techniques is presented. The advantages and drawbacks of each of these techniques are discussed. The results obtained from this analysis can be very useful for determining the most adapted technique for a given application. (author)

  10. ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY I: TECHNIQUE FUNDAMENTALS

    Directory of Open Access Journals (Sweden)

    Róbinson Torres

    Full Text Available Basic fundamentals of AC electrogravimetry are introduced. Their main requirements and characteristics are detailed to establish the design of an electronic system that allows the appropriate extraction of data needed to determine the electrogravimetric transfer function (EGTF and electrochemical impedance (EI, in an experimental set-up for the AC electrogravimetry technique.

  11. Progress in wind tunnel experimental techniques for wind turbine?

    Institute of Scientific and Technical Information of China (English)

    Jingping XIAO; Li CHEN; Qiang WANG; Qiao WANG

    2016-01-01

    Based on the unsteady aerodynamics experiment (UAE) phase VI and the model experiment in controlled conditions (MEXICO) projects and the related research carried out in China Aerodynamic Research and Development Center (CARDC), the recent progress in the wind tunnel experimental techniques for the wind turbine is sum-marized. Measurement techniques commonly used for di?erent types of wind tunnel ex-periments for wind turbine are reviewed. Important research achievements are discussed, such as the wind tunnel disturbance, the equivalence of the airfoil in?ow condition, the three-dimensional (3D) e?ect, the dynamic in?ow in?uence, the ?ow ?eld structure, and the vortex induction. The corresponding research at CARDC and some ideas on the large wind turbine are also introduced.

  12. Task Oriented Evaluation of Module Extraction Techniques

    Science.gov (United States)

    Palmisano, Ignazio; Tamma, Valentina; Payne, Terry; Doran, Paul

    Ontology Modularization techniques identify coherent and often reusable regions within an ontology. The ability to identify such modules, thus potentially reducing the size or complexity of an ontology for a given task or set of concepts is increasingly important in the Semantic Web as domain ontologies increase in terms of size, complexity and expressivity. To date, many techniques have been developed, but evaluation of the results of these techniques is sketchy and somewhat ad hoc. Theoretical properties of modularization algorithms have only been studied in a small number of cases. This paper presents an empirical analysis of a number of modularization techniques, and the modules they identify over a number of diverse ontologies, by utilizing objective, task-oriented measures to evaluate the fitness of the modules for a number of statistical classification problems.

  13. Evaluation of the Sealing Ability of Three Obturation Techniques Using a Glucose Leakage Test

    Directory of Open Access Journals (Sweden)

    Katarzyna Olczak

    2017-01-01

    Full Text Available The aim of this study was to evaluate the sealing ability of three different canal filling techniques. Sixty-four roots of extracted human maxillary anterior teeth were prepared using ProTaper® rotary instruments. The specimens were then randomly divided into 3 experimental groups (n=16 and 2 control groups (n=8. The root canals were filled using cold lateral compaction (CLC group, continuous wave condensation technique using the Elements Obturation Unit® (EOU group, and ProTaper obturators (PT group. For the negative control group, 8 roots were filled using lateral compaction as in the CLC group, and the teeth were covered twice with a layer of nail varnish (NCG group. Another 8 roots were filled using lateral compaction, but without sealer, and these were used as the positive control (PCG group. A glucose leakage model was used for quantitative evaluation of microleakage for 24 hours and 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, and 12 weeks. No significant difference in the cumulative amount of leakage was found between the three experimental groups at all observation times. The lateral condensation of cold gutta-percha can guarantee a similar seal of canal fillings as can be achieved by using thermal methods, in the round canals.

  14. Evaluation of effectiveness of cement removal from implant-retained crowns using a proposed circular crisscross flossing technique.

    Science.gov (United States)

    Ferreira, Cimara Fortes; Shafter, Mohamed Amer; Jain, Vinay; Wicks, Russel Anthony; Linder, Erno; Ledo, Carlos Alberto da Silva

    2018-02-13

    Extruded cement during dental implant crown cementation may cause peri-implant diseases if not removed adequately. Evaluate the efficiency of removal of cement after cementation of implant crowns using an experimental "circular crisscross flossing technique (CCCFT) flossing technique, compared to the conventional "C" shape flossing technique (CSFT). Twenty-four patients rendered 29 experimental and 29 control crowns. Prefabricated abutments were secured to the implant with the margins at least 1 mm subgingivally. The abutments were scanned using CADCAM technology and Emax crowns were fabricated in duplicates. Each crown was cemented separately and excess cement was removed using the CSFT and the CCFT techniques. After completion of cementation was completed, the screw access holes were accessed and the crown was unscrewed along with the abutment. The samples were disinfected using 70% ethanol for 10 minutes. Crowns were divided into 4 parts using a marker in order to facilitate measurement data collection. Vertical and horizontal measurements were made for extruded cement for each control and experimental groups by means of a digital microscope. One-hundred and seventeen measurements were made for each group. Mann-Whitney test was applied to verify statistical significance between the groups. The CCFT showed a highly statistically significant result (104.8 ± 13.66, pcrowns cementation when compared with the CSFT.

  15. Experimental evaluation of pumpjet propulsor for an axisymmetric body in wind tunnel

    Directory of Open Access Journals (Sweden)

    Ch. Suryanarayana

    2010-03-01

    Full Text Available Design of a Pump Jet Propulsor (PJP was undertaken for an underwater body with axisymmetric configuration using axial flow compressor design techniques supported by Computational Fluid Dynamics (CFD analysis for performance prediction. Experimental evaluation of the PJP was carried out through experiments in a Wind Tunnel Facility (WTF using momentum defect principle for propulsive performance prior to proceeding with extensive experimental evaluation in towing tank and cavitation tunnel. Experiments were particularly conducted with respect to Self Propulsion Point (SPP, residual torque and thrust characteristics over a range of vehicle advance ratio in order to ascertain whether sufficient thrust is developed at the design condition with least possible imbalance torque left out due to residual swirl in the slip stream. Pumpjet and body models were developed for the propulsion tests using Aluminum alloy forged material. Tests were conducted from 0 m/s to 30 m/s at four rotational speeds of the PJP. SPP was determined confirming the thrust development capability of PJP. Estimation of residual torque was carried out at SPP corresponding to speeds of 15, 20 and 25 m/s to examine the effectiveness of the stator. Estimation of thrust and residual torque was also carried out at wind speeds 0 and 6 m/s for PJP RPMs corresponding to self propulsion tests to study the propulsion characteristics during the launch of the vehicle in water where advance ratios are close to Zero. These results are essential to assess the thrust performance at very low advance ratios to accelerate the body and to control the body during initial stages. This technique has turned out to be very useful and economical method for quick assessment of overall performance of the propulsor and generation of exhaustive fluid dynamic data to validate CFD techniques employed.

  16. Development of an evaluation technique for human-machine interface

    Energy Technology Data Exchange (ETDEWEB)

    Min, Dae Hwan; Koo, Sang Hui; Ahn, Won Yeong; Ryu, Yeong Shin [Korea Univ., Seoul (Korea, Republic of)

    1997-07-15

    The purpose of this study is two-fold : firstly to establish an evaluation technique for HMI(Human Machine Interface) in NPPs(Nuclear Power Plants) and secondly to develop an architecture of a support system which can be used for the evaluation of HMI. In order to establish an evaluation technique, this study conducted literature review on basic theories of cognitive science studies and summarized the cognitive characteristics of humans. This study also surveyed evaluation techniques of HMI in general, and reviewed studies on the evaluation of HMI in NPPs. On the basis of this survey, the study established a procedure for the evaluation of HMI in NPPs in Korea and laid a foundation for empirical verification.

  17. Development of an evaluation technique for human-machine interface

    International Nuclear Information System (INIS)

    Min, Dae Hwan; Koo, Sang Hui; Ahn, Won Yeong; Ryu, Yeong Shin

    1997-07-01

    The purpose of this study is two-fold : firstly to establish an evaluation technique for HMI(Human Machine Interface) in NPPs(Nuclear Power Plants) and secondly to develop an architecture of a support system which can be used for the evaluation of HMI. In order to establish an evaluation technique, this study conducted literature review on basic theories of cognitive science studies and summarized the cognitive characteristics of humans. This study also surveyed evaluation techniques of HMI in general, and reviewed studies on the evaluation of HMI in NPPs. On the basis of this survey, the study established a procedure for the evaluation of HMI in NPPs in Korea and laid a foundation for empirical verification

  18. Evaluation of EMG processing techniques using Information Theory

    Directory of Open Access Journals (Sweden)

    Felice Carmelo J

    2010-11-01

    Full Text Available Abstract Background Electromyographic signals can be used in biomedical engineering and/or rehabilitation field, as potential sources of control for prosthetics and orthotics. In such applications, digital processing techniques are necessary to follow efficient and effectively the changes in the physiological characteristics produced by a muscular contraction. In this paper, two methods based on information theory are proposed to evaluate the processing techniques. Methods These methods determine the amount of information that a processing technique is able to extract from EMG signals. The processing techniques evaluated with these methods were: absolute mean value (AMV, RMS values, variance values (VAR and difference absolute mean value (DAMV. EMG signals from the middle deltoid during abduction and adduction movement of the arm in the scapular plane was registered, for static and dynamic contractions. The optimal window length (segmentation, abduction and adduction movements and inter-electrode distance were also analyzed. Results Using the optimal segmentation (200 ms and 300 ms in static and dynamic contractions, respectively the best processing techniques were: RMS, AMV and VAR in static contractions, and only the RMS in dynamic contractions. Using the RMS of EMG signal, variations in the amount of information between the abduction and adduction movements were observed. Conclusions Although the evaluation methods proposed here were applied to standard processing techniques, these methods can also be considered as alternatives tools to evaluate new processing techniques in different areas of electrophysiology.

  19. Physically-Based Interactive Flow Visualization Based on Schlieren and Interferometry Experimental Techniques

    KAUST Repository

    Brownlee, C.; Pegoraro, V.; Shankar, S.; McCormick, Patrick S.; Hansen, C. D.

    2011-01-01

    Understanding fluid flow is a difficult problem and of increasing importance as computational fluid dynamics (CFD) produces an abundance of simulation data. Experimental flow analysis has employed techniques such as shadowgraph, interferometry

  20. Evaluation of flow-induced vibration prediction techniques for in-reactor components

    International Nuclear Information System (INIS)

    Mulcahy, T.M.; Turula, P.

    1975-05-01

    Selected in-reactor components of a hydraulic and structural dynamic scale model of the U. S. Energy Research and Development Administration experimental Fast Test Reactor have been studied in an effort to develop and evaluate techniques for predicting vibration behavior of elastic structures exposed to a moving fluid. Existing analysis methods are used to compute the natural frequencies and modal shapes of submerged beam and shell type components. Component response is calculated, assuming as fluid forcing mechanisms both vortex shedding and random excitations characterized by the available hydraulic data. The free and force vibration response predictions are compared with extensive model flow and shaker test data. (U.S.)

  1. Calculation and experimental technique of determination of rolling procedure for cold-rolling tube mills

    International Nuclear Information System (INIS)

    Igoshin, V.F.; Aleshin, V.A.; Khoroshikh, Yu.G.; Bogatov, A.A.; Mizhiritskij, O.I.

    1983-01-01

    Calculation and experimental technique of determination of tube cold rolling procedure has been developed. Rolling procedure based on the usage of regression equation epsilon=1.24 psi, where psi is the relative reduction of area, delta-permissible reduction during rolling, has been tested on 08Kh18N10T steel. The effect of tube geometry, tool calibration parameters, lubrication conditions etc. on metal deformability in taking into account experimentally. The use of the technique proposed has allowed to shorten the time of mastering of the production of tubes from different steels

  2. Comparative evaluation of a two stroke compressed natural gas mixer design using simulation and experimental techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ramasamy, D.; Bakar, R.A.; Rahim, M.F.; Noor, M.M. [Malaysia Pahang Univ., Pahang (Malaysia). Automotive Focus Group

    2008-07-01

    A study was conducted in which a two-stroke engine was converted for use with bi-fuel, notably compressed natural gas and gasoline. The excessive by-products generated by two-stroke engine combustion can be attributed to the inefficient combustion process. This prototype uniflow-type single-cylinder engine was equipped with a bi-fuel conversion system. A dedicated mixer was also developed to meter the gaseous fuel through the engine intake system. It was designed to meet air and fuel requirement similar to its gasoline counterpart. The mixer was modeled to obtain optimum orifice diameter using three different sizes of 14, 16 and 18 mm respectively. A standard computational fluid dynamics (CFD) software package was used to simulate the flow. A pressure reading was obtained during the prototype test. The drop in pressure across the venturi was shown to be an important parameter as it determined the actual fuel-air ratio in the actual engine. A good agreement of CFD outputs with that of the experimental outputs was recorded. The experimental technique validated the pressure distribution predicted by CFD means on the effects of the three insert rings in the CNG mixer. The simulation exercise can be used to predict the amount of CNG consumed by the engine. It was concluded that the 14 mm throat ring was best suited for the CNG mixer because it provided the best suction. Once the mixer is tested on a real engine, it will clear any doubts as to whether the throat can function at high engine speeds. 5 refs., 3 tabs., 8 figs.

  3. Evaluation of the natural radioactivity using thermoluminescence, gamma spectrometry and neutron activation techniques

    International Nuclear Information System (INIS)

    Fausto, A.M.; Otsubo, S.M.; Paes, W.S.; Yoshimura, E.M.; Okuno, E.; Hiodo, F.; Marques, L.S.; Alcala, A.L.

    1996-01-01

    The evaluation of the radiation dose in the living species due to the natural radioactivity is the main objective of this paper. The region that had been monitored was Intrusive Suite of Itu near to Sao Paulo city. Lateral[and depth distributions of natural radioactivity of the soil were determined using the techniques of thermoluminescence gamma spectrometry and neutron[activation. From the concentration in the soil of K-40 and radioactive elements of U and Th series experimentally determined, the dose due to gamma rays in air at 1 m from the soil was evaluated and the results compared with the direct dose measured with the portable rate-meter. (authors). 11 refs., 3 figs

  4. Experimental evaluation of Arabic OCR systems

    Directory of Open Access Journals (Sweden)

    Mansoor Alghamdi

    2017-11-01

    Full Text Available Purpose – The aim of this paper is to experimentally evaluate the effectiveness of the state-of-the-art printed Arabic text recognition systems to determine open areas for future improvements. In addition, this paper proposes a standard protocol with a set of metrics for measuring the effectiveness of Arabic optical character recognition (OCR systems to assist researchers in comparing different Arabic OCR approaches. Design/methodology/approach – This paper describes an experiment to automatically evaluate four well-known Arabic OCR systems using a set of performance metrics. The evaluation experiment is conducted on a publicly available printed Arabic dataset comprising 240 text images with a variety of resolution levels, font types, font styles and font sizes. Findings – The experimental results show that the field of character recognition for printed Arabic still requires further research to reach an efficient text recognition method for Arabic script. Originality/value – To the best of the authors’ knowledge, this is the first work that provides a comprehensive automated evaluation of Arabic OCR systems with respect to the characteristics of Arabic script and, in addition, proposes an evaluation methodology that can be used as a benchmark by researchers and therefore will contribute significantly to the enhancement of the field of Arabic script recognition.

  5. Performability Modelling Tools, Evaluation Techniques and Applications

    NARCIS (Netherlands)

    Haverkort, Boudewijn R.H.M.

    1990-01-01

    This thesis deals with three aspects of quantitative evaluation of fault-tolerant and distributed computer and communication systems: performability evaluation techniques, performability modelling tools, and performability modelling applications. Performability modelling is a relatively new

  6. Experimental models of brain ischemia: a review of techniques, magnetic resonance imaging and investigational cell-based therapies

    Directory of Open Access Journals (Sweden)

    Alessandra eCanazza

    2014-02-01

    Full Text Available Stroke continues to be a significant cause of death and disability worldwide. Although major advances have been made in the past decades in prevention, treatment and rehabilitation, enormous challenges remain in the way of translating new therapeutic approaches from bench to bedside. Thrombolysis, while routinely used for ischemic stroke, is only a viable option within a narrow time window. Recently, progress in stem cell biology has opened up avenues to therapeutic strategies aimed at supporting and replacing neural cells in infarcted areas. Realistic experimental animal models are crucial to understand the mechanisms of neuronal survival following ischemic brain injury and to develop therapeutic interventions. Current studies on experimental stroke therapies evaluate the efficiency of neuroprotective agents and cell-based approaches using primarily rodent models of permanent or transient focal cerebral ischemia. In parallel, advancements in imaging techniques permit better mapping of the spatial-temporal evolution of the lesioned cortex and its functional responses. This review provides a condensed conceptual review of the state of the art of this field, from models and magnetic resonance imaging techniques through to stem cell therapies.

  7. RELIABILITY OF CERTAIN TESTS FOR EVALUATION OF JUDO TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Slavko Obadov

    2007-05-01

    Full Text Available The sample included 106 judokas. Assessment of the level of mastership of judo techniques was carried out by evaluation of fi ve competent studies. Each subject performed a technique three times and each performance was evaluated by the judges. In order to evaluate measurement of each technique, Cronbach’s coeffi cient of reliability  was calculated. During the procedure the subjects's results were also transformed to factor scores i.e. the results of each performer at the main component of evaluation in the fi ve studies. These factor scores could be used in the subsequent procedure of multivariant statistical analysis.

  8. Evaluation of deformation and fracture characteristics of nuclear reactor materials using ball indentation test technique

    International Nuclear Information System (INIS)

    Byun, T. S.; Hong, J. H.; Lee, B. S.; Park, D. G.; Kim, J. H.; Oh, Y. J.; Yoon, J. H.; Chi, S. H.; Kuk, I. H.; Kwon, D. I.; Lee, J. H.

    1998-05-01

    The present report describes the automated ball indentation test techniques and the results of their applications. The ball indentation test technique is an innovative method for evaluating the key mechanical properties from the indentation load-depth data. In the 1st chapter, the existing technique for evaluating basic deformation (tensile) properties is described in detail, and also the application result of the technique is presented. The through-thickness variations of mechanical properties in SA 508 C1.3 reactor pressure vessel steels were measured using an automated ball indentation (ABI) technique. In the 2nd chapter, a method under development, which is similar to that in the 1st chapter, is new method is based on the theoretical solutions rather than experimental relationships. The result of the application showed that the stress-strain curves of various metals were successfully determined with the method. In the 3rd chapter, a new theoretical model was proposed to estimate the fracture toughness of ferritic steels in the transition temperature region. The key concept of the model is that the indention energy to a critical load is related to the fracture energy of the material. The theory was applied to the reactor pressure vessel (RPV) base and weld metals. (author). 24 refs., 3 tabs., 6 figs

  9. Covariance data evaluation for experimental data

    International Nuclear Information System (INIS)

    Liu Tingjin

    1993-01-01

    Some methods and codes have been developed and utilized for covariance data evaluation of experimental data, including parameter analysis, physical analysis, Spline fitting etc.. These methods and codes can be used in many different cases

  10. Aerosols from metal cutting techniques typical of decommissioning nuclear facilities - experimental system for collection and characterization

    International Nuclear Information System (INIS)

    Newton, G.J.; Hoover, M.D.; Barr, E.B.; Wong, B.A.; Ritter, P.D.

    1982-01-01

    Decommissioning of radioactively contaminated sites has the potential for creating radioactive and other potentially toxic aerosols. We describe an experimental system to collect and characterize aerosols from metal cutting activities typical of those used in decommissioning of nuclear facilities. A special enclosure was designed for the experiment and consisted of a 2-in. x 4-in. stud frame with double walls of flame retardant polyethylene film. Large plexiglass windows allowed the cutting operations to be directed and filmed. Ventilation was 8500 L/min (300 CFM) exhausted through HEPA filters. Seven cutting techniques were evaluated: pipe cutter, reciprocating saw, band saw, chop saw, oxy-acetylene torch, electric arc cut rod and plasma torch. Two grinding tools were also evaluated. Materials cut were 2-, 3- and 4-in. dia schedule 40, 80 and 180 type 304L stainless steel pipe. Basic studies were done on uncontaminated pipe. Four-inch-diameter sections of schedule 180 type 304L stainless steel pipe with radioactively contaminated internal surfaces were also cut. The experiments controlled important variables including tools, cutting technique, and type and thickness of material. 15 references, 4 figures, 2 tables

  11. Statistical evaluation of vibration analysis techniques

    Science.gov (United States)

    Milner, G. Martin; Miller, Patrice S.

    1987-01-01

    An evaluation methodology is presented for a selection of candidate vibration analysis techniques applicable to machinery representative of the environmental control and life support system of advanced spacecraft; illustrative results are given. Attention is given to the statistical analysis of small sample experiments, the quantification of detection performance for diverse techniques through the computation of probability of detection versus probability of false alarm, and the quantification of diagnostic performance.

  12. Development of evaluation method for software safety analysis techniques

    International Nuclear Information System (INIS)

    Huang, H.; Tu, W.; Shih, C.; Chen, C.; Yang, W.; Yih, S.; Kuo, C.; Chen, M.

    2006-01-01

    Full text: Full text: Following the massive adoption of digital Instrumentation and Control (I and C) system for nuclear power plant (NPP), various Software Safety Analysis (SSA) techniques are used to evaluate the NPP safety for adopting appropriate digital I and C system, and then to reduce risk to acceptable level. However, each technique has its specific advantage and disadvantage. If the two or more techniques can be complementarily incorporated, the SSA combination would be more acceptable. As a result, if proper evaluation criteria are available, the analyst can then choose appropriate technique combination to perform analysis on the basis of resources. This research evaluated the applicable software safety analysis techniques nowadays, such as, Preliminary Hazard Analysis (PHA), Failure Modes and Effects Analysis (FMEA), Fault Tree Analysis (FTA), Markov chain modeling, Dynamic Flowgraph Methodology (DFM), and simulation-based model analysis; and then determined indexes in view of their characteristics, which include dynamic capability, completeness, achievability, detail, signal/ noise ratio, complexity, and implementation cost. These indexes may help the decision makers and the software safety analysts to choose the best SSA combination arrange their own software safety plan. By this proposed method, the analysts can evaluate various SSA combinations for specific purpose. According to the case study results, the traditional PHA + FMEA + FTA (with failure rate) + Markov chain modeling (without transfer rate) combination is not competitive due to the dilemma for obtaining acceptable software failure rates. However, the systematic architecture of FTA and Markov chain modeling is still valuable for realizing the software fault structure. The system centric techniques, such as DFM and Simulation-based model analysis, show the advantage on dynamic capability, achievability, detail, signal/noise ratio. However, their disadvantage are the completeness complexity

  13. Technique development for modulus, microcracking, hermeticity, and coating evaluation capability characterization of SiC/SiC tubes

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Xunxiang [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Ang, Caen K. [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Singh, Gyanender P. [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Katoh, Yutai [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)

    2016-08-01

    Driven by the need to enlarge the safety margins of nuclear fission reactors in accident scenarios, research and development of accident-tolerant fuel has become an important topic in the nuclear engineering and materials community. A continuous-fiber SiC/SiC composite is under consideration as a replacement for traditional zirconium alloy cladding owing to its high-temperature stability, chemical inertness, and exceptional irradiation resistance. An important task is the development of characterization techniques for SiC/SiC cladding, since traditional work using rectangular bars or disks cannot directly provide useful information on the properties of SiC/SiC composite tubes for fuel cladding applications. At Oak Ridge National Laboratory, experimental capabilities are under development to characterize the modulus, microcracking, and hermeticity of as-fabricated, as-irradiated SiC/SiC composite tubes. Resonant ultrasound spectroscopy has been validated as a promising technique to evaluate the elastic properties of SiC/SiC composite tubes and microcracking within the material. A similar technique, impulse excitation, is efficient in determining the basic mechanical properties of SiC bars prepared by chemical vapor deposition; it also has potential for application in studying the mechanical properties of SiC/SiC composite tubes. Complete evaluation of the quality of the developed coatings, a major mitigation strategy against gas permeation and hydrothermal corrosion, requires the deployment of various experimental techniques, such as scratch indentation, tensile pulling-off tests, and scanning electron microscopy. In addition, a comprehensive permeation test station is being established to assess the hermeticity of SiC/SiC composite tubes and to determine the H/D/He permeability of SiC/SiC composites. This report summarizes the current status of the development of these experimental capabilities.

  14. Advanced Computational and Experimental Techniques for Nacelle Liner Performance Evaluation

    Science.gov (United States)

    Gerhold, Carl H.; Jones, Michael G.; Brown, Martha C.; Nark, Douglas

    2009-01-01

    The Curved Duct Test Rig (CDTR) has been developed to investigate sound propagation through a duct of size comparable to the aft bypass duct of typical aircraft engines. The axial dimension of the bypass duct is often curved and this geometric characteristic is captured in the CDTR. The semiannular bypass duct is simulated by a rectangular test section in which the height corresponds to the circumferential dimension and the width corresponds to the radial dimension. The liner samples are perforate over honeycomb core and are installed on the side walls of the test section. The top and bottom surfaces of the test section are acoustically rigid to simulate a hard wall bifurcation or pylon. A unique feature of the CDTR is the control system that generates sound incident on the liner test section in specific modes. Uniform air flow, at ambient temperature and flow speed Mach 0.275, is introduced through the duct. Experiments to investigate configuration effects such as curvature along the flow path on the acoustic performance of a sample liner are performed in the CDTR and reported in this paper. Combinations of treated and acoustically rigid side walls are investigated. The scattering of modes of the incident wave, both by the curvature and by the asymmetry of wall treatment, is demonstrated in the experimental results. The effect that mode scattering has on total acoustic effectiveness of the liner treatment is also shown. Comparisons of measured liner attenuation with numerical results predicted by an analytic model based on the parabolic approximation to the convected Helmholtz equation are reported. The spectra of attenuation produced by the analytic model are similar to experimental results for both walls treated, straight and curved flow path, with plane wave and higher order modes incident. The numerical model is used to define the optimized resistance and reactance of a liner that significantly improves liner attenuation in the frequency range 1900-2400 Hz. A

  15. Anterior Colporrhaphy Technique and Approach Choices: Turkey Evaluation

    Directory of Open Access Journals (Sweden)

    Serdar Aydın

    2016-09-01

    Full Text Available Aim: To evaluate the diversity in techniques and approaches for anterior colporrhaphy among operators in Turkey. Methods: A survey evaluating the preoperative examination, technique of anterior colporrhaphy, operation choice and postoperative care was presented to surgeons. We contacted via directly, mail or telephone. We used 28 item questionnaire. Results: Majority (87.9% was composed of young gynecologists. Urologists composed of the 9.5% of the study population. The rate of paravaginal defect evaluation was 75.9% and mostly by inspection the presence of vaginal rugae. The use of transperineal 3D pelvic floor ultrasonography was low (5.7%. The evaluation of levator ani muscle defect was 46.6%. The usage of the transperineal 3D ultrasonography for levator ani muscle defect was 19 percent of operators. There were diversity in use of hydrodissection, fascial plication, excision of vaginal mucosa and suture choice. Usage of mesh for anterior colporrhaphy was limited (17.8% and mostly in recurrent cases (12.2%. Paravaginal defect repair rate was 31.9%. The urinary catheter was generally removed one or two day after operation. Vaginal pack usually removed 24 hours after. Conclusion: Several techniques and approaches for anterior vaginal wall repair among operators in Turkey. The variety of techniques suggested that there is no consensus on best surgical technique.

  16. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    International Nuclear Information System (INIS)

    Pereira, L M C

    2017-01-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials. (topical review)

  17. Experimentally evaluating the origin of dilute magnetism in nanomaterials

    Science.gov (United States)

    Pereira, L. M. C.

    2017-10-01

    Reports of room-temperature ferromagnetism continue to emerge for an ever-growing range of nanomaterials with a small or even vanishing concentration of magnetic atoms. Dilute magnetic semiconductors (DMS) are the most representative class of such materials, but similar magnetic properties have been reported in many others. Challenging our understanding of magnetic order in solids, as well as our ability to experimentally assess it, these remarkable magnetic phenomena have become one of the most controversial topics in magnetism. Various non-intrinsic sources of ferromagnetism (e.g. instrumental artifacts and magnetic contamination) are becoming well documented, and rarely are all of them taken into account when room-temperature ferromagnetism is reported. This topical review is intended to serve as a guide when evaluating to what extent a given data set supports the claim of intrinsic ferromagnetism in dilute nanomaterials. It compiles the most relevant sources of non-intrinsic ferromagnetism which have been reported, as well as guidelines for how to minimize them. It also provides an overview of complementary structural and magnetic characterization techniques which can be combined to provide different levels of scrutiny of the intrinsic nature of experimentally observed ferromagnetism. In particular, it gives some notable examples of how comprehensive studies based on those techniques have led to a remarkably detailed understanding of model DMS materials, with strong evidence of absence of room-temperature ferromagnetism. Although mostly based on DMS research, this review provides a set of guidelines and cautionary notes of broader relevance, including some emerging new fields of dilute nanomagnetism such as magnetically doped 3D topological insulators, 3D Dirac semimetals, and 2D materials.

  18. Comparative study of linear and nonlinear ultrasonic techniques for evaluation thermal damage of tube like structures

    International Nuclear Information System (INIS)

    Li, Weibin; Cho, Younho; Li, Xianqiang

    2013-01-01

    Ultrasonic guided wave techniques have been widely used for long range nondestructive detection in tube like structures. The present paper investigates the ultrasonic linear and nonlinear parameters for evaluating the thermal damage in aluminum pipe. Specimens were subjected to thermal loading. Flexible polyvinylidene fluoride (PVDF) comb transducers were used to generate and receive the ultrasonic waves. The second harmonic wave generation technique was used to check the material nonlinearity change after different heat loadings. The conventional linear ultrasonic approach based on attenuation was also used to evaluate the thermal damages in specimens. The results show that the proposed experimental setup is viable to assess the thermal damage in an aluminum pipe. The ultrasonic nonlinear parameter is a promising candidate for the prediction of micro damages in a tube like structure

  19. An Experimental Evaluation of the DQ-DHT Algorithm in a Grid Information Service

    Science.gov (United States)

    Papadakis, Harris; Trunfio, Paolo; Talia, Domenico; Fragopoulou, Paraskevi

    DQ-DHT is a resource discovery algorithm that combines the Dynamic Querying (DQ) technique used in unstructured peer-to-peer networks with an algorithm for efficient broadcast over a Distributed Hash Table (DHT). Similarly to DQ, DQ-DHT dynamically controls the query propagation on the basis of the desired number of results and the popularity of the resource to be located. Differently from DQ, DQ-DHT exploits the structural properties of a DHT to avoid message duplications, thus reducing the amount of network traffic generated by each query. The goal of this paper is to evaluate experimentally the amount of traffic generated by DQ-DHT compared to the DQ algorithm in a Grid infrastructure. A prototype of a Grid information service, which can use both DQ and DQ-DHT as resource discovery algorithm, has been implemented and deployed on the Grid'5000 infrastructure for evaluation. The experimental results presented in this paper show that DQ-DHT significantly reduces the amount of network traffic generated during the discovery process compared to the original DQ algorithm.

  20. Experimental device for obtaining calibration factor for the total count technique

    International Nuclear Information System (INIS)

    Gonçalves, Eduardo R.; Braz, Delson; Brandão, Luís Eduardo B.

    2017-01-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  1. Experimental device for obtaining calibration factor for the total count technique

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Eduardo R.; Braz, Delson [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Brandão, Luís Eduardo B. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Divisao de Reatores

    2017-07-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  2. Evaluation of marginal gap of Ni-Cr copings made with conventional and accelerated casting techniques.

    Science.gov (United States)

    Tannamala, Pavan Kumar; Azhagarasan, Nagarasampatti Sivaprakasam; Shankar, K Chitra

    2013-01-01

    Conventional casting techniques following the manufacturers' recommendations are time consuming. Accelerated casting techniques have been reported, but their accuracy with base metal alloys has not been adequately studied. We measured the vertical marginal gap of nickel-chromium copings made by conventional and accelerated casting techniques and determined the clinical acceptability of the cast copings in this study. Experimental design, in vitro study, lab settings. Ten copings each were cast by conventional and accelerated casting techniques. All copings were identical, only their mold preparation schedules differed. Microscopic measurements were recorded at ×80 magnification on the perpendicular to the axial wall at four predetermined sites. The marginal gap values were evaluated by paired t test. The mean marginal gap by conventional technique (34.02 μm) is approximately 10 μm lesser than that of accelerated casting technique (44.62 μm). As the P value is less than 0.0001, there is highly significant difference between the two techniques with regard to vertical marginal gap. The accelerated casting technique is time saving and the marginal gap measured was within the clinically acceptable limits and could be an alternative to time-consuming conventional techniques.

  3. Experimental Verification of Interference Mitigation Techniques for 5G Small Cells

    DEFF Research Database (Denmark)

    Assefa, Dereje; Berardinelli, Gilberto; Tavares, Fernando Menezes Leitão

    2015-01-01

    deployment with four cells, where each cell features one Access Point (AP) and one User Equipment (UE). In particular, we compare traditional Frequency Reuse Planning (FRP) with the recently proposed Maximum Rank Planning (MRP) technique, which relies on the degrees of freedom offered by the multi...... with the USRP N200 hardware by Ettus Research. The experimental results in a fully loaded network reveal the capability of the MRP technique to achieve higher throughput performance than FRP for 90% of the cases when IRC receivers are used. Lower network loads lead to further performance improvements for MRP....

  4. Experimental comparison of particle interaction measurement techniques using optical traps

    International Nuclear Information System (INIS)

    Koehler, Timothy P.; Grillet, Anne Mary; Brotherton, Christopher M.; Molecke, Ryan A.

    2008-01-01

    Optical tweezers has become a powerful and common tool for sensitive determination of electrostatic interactions between colloidal particles. Recently, two techniques, 'blinking' tweezers and direct force measurements, have become increasingly prevalent in investigations of inter-particle potentials. The 'blinking' tweezers method acquires physical statistics of particle trajectories to determine drift velocities, diffusion coefficients, and ultimately colloidal forces as a function of the center-center separation of two particles. Direct force measurements monitor the position of a particle relative to the center of an optical trap as the separation distance between two continuously trapped particles is gradually decreased. As the particles near each other, the displacement from the trap center for each particle increases proportional to the inter-particle force. Although commonly employed in the investigation of interactions of colloidal particles, there exists no direct comparison of these experimental methods in the literature. In this study, an experimental apparatus was developed capable of performing both methods and is used to quantify electrostatic potentials between particles in several particle/solvent systems. Comparisons are drawn between the experiments conducted using the two measurement techniques, theory, and existing literature. Forces are quantified on the femto-Newton scale and results agree well with literature values

  5. Experimental Study on Corrosion Detection of Aluminum Alloy Using Lamb Wave Mixing Technique

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Heeung; Lee, Jaesun; Cho, Younho [Pusan Nat’l Univ., Busan (Korea, Republic of)

    2016-11-15

    In this study, the Lamb wave mixing technique, which is basised on advanced research on the nonlinear bulk wave mixing technique, is applied for corrosion detection. To demonstrate the validity of the Lamb wave mixing technique, an experiment was performed with normal and corroded specimens. Comparison group in an experimentation are selected to mode and frequency with dominant in-plane displacement and out-of-plane displacement of Lamb waves. The results showed that the Lamb wave mixing technique can monitor corrosion defects, and it has a trend similar to that of the conventional Lamb wave technique. It was confirmed that the dominant displacement and mode matching the theory were generated. Flaw detectability is determined depending on displacement ratio instead of using the measurement method and mode selection.

  6. Experimental techniques for characterising water in wood covering the range from dry to fully water-saturated

    DEFF Research Database (Denmark)

    Thybring, Emil Engelund; Kymäläinen, Maija; Rautkari, Lauri

    2018-01-01

    focuses on selected experimental techniques that can give deeper insights into various aspects of water in wood in the entire moisture domain from dry to fully water-saturated. These techniques fall into three broad categories: (1) gravimetric techniques that determine how much water is absorbed, (2...

  7. Experimental evaluations of wearable ECG monitor.

    Science.gov (United States)

    Ha, Kiryong; Kim, Youngsung; Jung, Junyoung; Lee, Jeunwoo

    2008-01-01

    Healthcare industry is changing with ubiquitous computing environment and wearable ECG measurement is one of the most popular approaches in this healthcare industry. Reliability and performance of healthcare device is fundamental issue for widespread adoptions, and interdisciplinary perspectives of wearable ECG monitor make this more difficult. In this paper, we propose evaluation criteria considering characteristic of both ECG measurement and ubiquitous computing. With our wearable ECG monitors, various levels of experimental analysis are performed based on evaluation strategy.

  8. Fuel performance evaluation for the CAFE experimental device

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Hirota, Leandro T.

    2011-01-01

    Fuel rod cladding material is the second barrier to prevent the release of radioactive inventories in a PWR reactor. In this sense, an important safety aspect is to assess the fuel behavior under operational conditions. This can be made by means of fuel performance codes and confirmed by experimental measurements. In order to evaluate the fuel behavior of fuel rods in steady-state conditions, it was designed an experimental irradiation device, the Nuclear Fuel Irradiation Circuit (CAFE-Mod1). This device will allow controlling the surface rod temperature, to measure the power associated to the rod and the evolution of fission gas release for a typical PWR fuel pin. However, to support the experimental irradiation program, it is extremely important to simulate the experimental conditions using a fuel performance code. The aim of this paper is to evaluate some parameters and aspects related to the fuel rod behavior during the irradiation program. This evaluation was carried out by means of an adapted fuel performance code. Obtained results have shown that besides of the variation observed for parameters, such as, fuel temperature and fission gas release as a function of fuel enrichment level, the fuel rod integrity was preserved in all studied conditions. (author)

  9. Evaluation of concrete pavement patching techniques.

    Science.gov (United States)

    1989-01-01

    This final report presents the results of a study undertaken to improve in concrete pavement patching techniques. Activities included an evaluation of the suitability of the impact hammer and maturity calculations for determining when a patch is read...

  10. Experimental investigation of consumer price evaluations

    NARCIS (Netherlands)

    Z. Sándor (Zsolt); Ph.H.B.F. Franses (Philip Hans)

    2004-01-01

    textabstractWe develop a procedure to collect experimental choice data for estimating consumer preferences with a special focus on consumer price evaluations. For this purpose we employ a heteroskedastic mixed logit model that measures the effect of the way prices are specified on the variance of

  11. Nicotinamides: Evaluation of thermochemical experimental properties

    International Nuclear Information System (INIS)

    Zhabina, Aleksandra A.; Nagrimanov, Ruslan N.; Emel’yanenko, Vladimir N.; Solomonov, Boris N.; Verevkin, Sergey P.

    2016-01-01

    Highlights: • Vapor pressures measured by transpiration method. • Enthalpies of solution measured using high-precision solution calorimetry. • Enthalpies of fusion measured by DSC. • Sublimation enthalpies derived from transpiration and solution calorimetry in agreement. • Experimental results evaluated and compared with G4 calculations. - Abstract: Vapor pressures of the isomeric 2-, 3-, and 4-pyridinecarboxamides were measured by using the transpiration method. The enthalpies of sublimation/vaporization of these compounds at 298.15 K were derived from vapor pressure temperature dependences. The enthalpies of solution of the isomeric pyridinecarboxamides were measured with the high-precision solution calorimetry. The enthalpies of sublimation of 3- and 4-pyridinecarboxamides were independently derived with help of the solution calorimetry based procedure. The enthalpies of fusion of the pyridinecarboxamides were measured by the DSC. Thermochemical data isomeric pyridinecarboxamides were collected, evaluated, and tested for internal consistency. The high-level G4 quantum-chemical method was used for mutual validation of the experimental and theoretical gas phase enthalpies of formation successfully.

  12. RPERT: Repetitive-Projects Evaluation and Review Technique

    Directory of Open Access Journals (Sweden)

    Remon Fayek Aziz

    2014-03-01

    Full Text Available Estimating expected completion probability of any repetitive construction project with a specified/certain duration including repetitive identical activities by using program evaluation and review technique is the most essential part in construction areas since the activities were had optimistic, most likely and pessimistic durations. This paper focuses on the calculation of expected completion probability of any repetitive construction project within a specified/certain duration (contract duration by using Line Of Balance technique (LOB in case of single or multiple number of crews integrated with Program Evaluation and Review Technique (PERT. Repetitive-Projects Evaluation and Review Technique (RPERT, which is a simplified software, will generate the expected project completion probability of a specified/certain duration (contract duration. RPERT software is designed by java programming code system to provide a number of new and unique capabilities, including: (1 Viewing the expected project completion probability according to a set of specified durations per each identical activity (optimistic time, most likely time, and pessimistic time in the analyzed project; (2 Providing seamless integration with available project time calculations. In order to provide the aforementioned capabilities of RPERT, the system is implemented and developed in four main modules: (1 A user interface module; (2 A database module; (3 A running module; and (4 A processing module. At the end, an illustrative example will be presented to demonstrate and verify the applications of proposed software (RPERT, by using probabilistic calculations for repetitive construction projects.

  13. Experimental research on application of mutual-aid teaching method in technique teaching of university’s football elective course

    Directory of Open Access Journals (Sweden)

    Wu Jiarong

    2016-01-01

    Full Text Available With the social development and reform of education system, the quality-oriented education and lifelong education gradually become education reform goals of colleges and universities, the physical education of the higher education and university are also developed. This research adopts the literature data method, ques-tionnaire method, experimental method, mathematical statistics or other methods to do experiments for the stu-dents who take the football elective course (a total of 36 class hours per semester in Zhuhai College of Jilin University with the mutual-aid teaching method. The experimental results show that: First, there is a significant difference between achievements of the specific football technique of the students in the experimental group and the students in the control group (P <0.05; second, in the teaching evaluation, the failure rate of the students in the experimental group significantly reduces, and the pass rate and good rate significantly increases after experi-ment; third, the majority of students accept the mutual-aid teaching method; fourth, the mutual-aid teaching method can be used to significantly improve the learning motivation level of the students.

  14. Development of evaluation method for software hazard identification techniques

    International Nuclear Information System (INIS)

    Huang, H. W.; Chen, M. H.; Shih, C.; Yih, S.; Kuo, C. T.; Wang, L. H.; Yu, Y. C.; Chen, C. W.

    2006-01-01

    This research evaluated the applicable software hazard identification techniques nowadays, such as, Preliminary Hazard Analysis (PHA), Failure Modes and Effects Analysis (FMEA), Fault Tree Analysis (FTA), Markov chain modeling, Dynamic Flow-graph Methodology (DFM), and simulation-based model analysis; and then determined indexes in view of their characteristics, which include dynamic capability, completeness, achievability, detail, signal/noise ratio, complexity, and implementation cost. By this proposed method, the analysts can evaluate various software hazard identification combinations for specific purpose. According to the case study results, the traditional PHA + FMEA + FTA (with failure rate) + Markov chain modeling (with transfer rate) combination is not competitive due to the dilemma for obtaining acceptable software failure rates. However, the systematic architecture of FTA and Markov chain modeling is still valuable for realizing the software fault structure. The system centric techniques, such as DFM and simulation-based model-analysis, show the advantage on dynamic capability, achievability, detail, signal/noise ratio. However, their disadvantages are the completeness complexity and implementation cost. This evaluation method can be a platform to reach common consensus for the stakeholders. Following the evolution of software hazard identification techniques, the evaluation results could be changed. However, the insight of software hazard identification techniques is much more important than the numbers obtained by the evaluation. (authors)

  15. Critical evaluation of sample pretreatment techniques.

    Science.gov (United States)

    Hyötyläinen, Tuulia

    2009-06-01

    Sample preparation before chromatographic separation is the most time-consuming and error-prone part of the analytical procedure. Therefore, selecting and optimizing an appropriate sample preparation scheme is a key factor in the final success of the analysis, and the judicious choice of an appropriate procedure greatly influences the reliability and accuracy of a given analysis. The main objective of this review is to critically evaluate the applicability, disadvantages, and advantages of various sample preparation techniques. Particular emphasis is placed on extraction techniques suitable for both liquid and solid samples.

  16. Financial Evaluation Techniques, Institutions and Innovation

    DEFF Research Database (Denmark)

    Howells, John

    2003-01-01

    This paper reviews the relationship between financial evaluation and control techniques and innovative activity in a range of technological contexts. The relationship is broadly conceived to include both the financial techniques developed and deployed within the firm and theevaluative behaviour...... of financial institutions external to the firm such as venture capital and industrial investment banking. With innovative and investment opportunities tending to vary over time within an industry, it becomes apparent that there can be no permanent solution to the common problem of how to trade off financial...

  17. Evaluation of Extrusion Technique for Nanosizing Liposomes

    Directory of Open Access Journals (Sweden)

    Sandy Gim Ming Ong

    2016-12-01

    Full Text Available The aim of the present study was to study the efficiency of different techniques used for nanosizing liposomes. Further, the aim was also to evaluate the effect of process parameters of extrusion techniques used for nanosizing liposomes on the size and size distribution of the resultant liposomes. To compare the efficiency of different nanosizing techniques, the following techniques were used to nanosize the liposomes: extrusion, ultrasonication, freeze-thaw sonication (FTS, sonication and homogenization. The extrusion technique was found to be the most efficient, followed by FTS, ultrasonication, sonication and homogenization. The extruder used in the present study was fabricated using readily available and relatively inexpensive apparatus. Process parameters were varied in extrusion technique to study their effect on the size and size distribution of extruded liposomes. The results obtained indicated that increase in the flow rate of the extrusion process decreased the size of extruded liposomes however the size homogeneity was negatively impacted. Furthermore, the liposome size and distribution was found to decline with decreasing membrane pore size. It was found that by extruding through a filter with a pore size of 0.2 µm and above, the liposomes produced were smaller than the pore size, whereas, when they were extruded through a filter with a pore size of less than 0.2 µm the resultant liposomes were slightly bigger than the nominal pore size. Besides that, increment of extrusion temperature above transition temperature of the pro-liposome had no effect on the size and size distribution of the extruded liposomes. In conclusion, the extrusion technique was reproducible and effective among all the methods evaluated. Furthermore, processing parameters used in extrusion technique would affect the size and size distribution of liposomes. Therefore, the process parameters need to be optimized to obtain a desirable size range and homogeneity

  18. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Science.gov (United States)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  19. Assessment and evaluation of ceramic filter cleaning techniques: Task Order 19

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H.; Zaharchuk, R.; Harbaugh, L.B.; Klett, M.

    1994-10-01

    The objective of this study was to assess and evaluate the effectiveness, appropriateness and economics of ceramic barrier filter cleaning techniques used for high-temperature and high-pressure particulate filtration. Three potential filter cleaning techniques were evaluated. These techniques include, conventional on-line pulse driven reverse gas filter cleaning, off-line reverse gas filter cleaning and a novel rapid pulse driven filter cleaning. These three ceramic filter cleaning techniques are either presently employed, or being considered for use, in the filtration of coal derived gas streams (combustion or gasification) under high-temperature high-pressure conditions. This study was divided into six subtasks: first principle analysis of ceramic barrier filter cleaning mechanisms; operational values for parameters identified with the filter cleaning mechanisms; evaluation and identification of potential ceramic filter cleaning techniques; development of conceptual designs for ceramic barrier filter systems and ceramic barrier filter cleaning systems for two DOE specified power plants; evaluation of ceramic barrier filter system cleaning techniques; and final report and presentation. Within individual sections of this report critical design and operational issues were evaluated and key findings were identified.

  20. Application of Modern Experimental Technique to Solve Morphological Complexity in Plants Taxonomy

    Directory of Open Access Journals (Sweden)

    SURANTO

    2000-07-01

    Full Text Available Modern taxonomy has two approaches, i.e. classical and experimental taxonomy. Classical taxonomy uses morphological characters, while experimental taxonomy uses broader methods including chemistry, physics and mathematics, in the form of laboratory data that are revealed together with the progress of optical technique (microscope, chemistry methods (chromatography, electrophoresis, etc. Modern taxonomy tends to use series of interrelated data. More data used would result in more validity and give better clarification of taxonomic status. A lot of modern taxonomic data such as palynology, cytotaxonomy (cytology, chemical constituent (chemotaxonomy, isozyme and DNA sequencing were used recently.

  1. MUP, CEC-DES, STRADE. Codes for uncertainty propagation, experimental design and stratified random sampling techniques

    International Nuclear Information System (INIS)

    Amendola, A.; Astolfi, M.; Lisanti, B.

    1983-01-01

    The report describes the how-to-use of the codes: MUP (Monte Carlo Uncertainty Propagation) for uncertainty analysis by Monte Carlo simulation, including correlation analysis, extreme value identification and study of selected ranges of the variable space; CEC-DES (Central Composite Design) for building experimental matrices according to the requirements of Central Composite and Factorial Experimental Designs; and, STRADE (Stratified Random Design) for experimental designs based on the Latin Hypercube Sampling Techniques. Application fields, of the codes are probabilistic risk assessment, experimental design, sensitivity analysis and system identification problems

  2. Using the Delphi technique in economic evaluation: time to revisit the oracle?

    Science.gov (United States)

    Simoens, S

    2006-12-01

    Although the Delphi technique has been commonly used as a data source in medical and health services research, its application in economic evaluation of medicines has been more limited. The aim of this study was to describe the methodology of the Delphi technique, to present a case for using the technique in economic evaluation, and to provide recommendations to improve such use. The literature was accessed through MEDLINE focusing on studies discussing the methodology of the Delphi technique and economic evaluations of medicines using the Delphi technique. The Delphi technique can be used to provide estimates of health care resources required and to modify such estimates when making inter-country comparisons. The Delphi technique can also contribute to mapping the treatment process under investigation, to identifying the appropriate comparator to be used, and to ensuring that the economic evaluation estimates cost-effectiveness rather than cost-efficacy. Ideally, economic evaluations of medicines should be based on real-patient data. In the absence of such data, evaluations need to incorporate the best evidence available by employing approaches such as the Delphi technique. Evaluations based on this approach should state the limitations, and explore the impact of the associated uncertainty in the results.

  3. Feasibility study on diagnosis of material damage using bulk wave mixing technique

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jeong Seok; Cho, Youn Ho [Pusan National University, Busan (Korea, Republic of)

    2016-02-15

    Ultrasonic nonlinear evaluation is generally utilized for detection of not only defects but also microdamage such as corrosion and plastic deformation. Nonlinearity is determined by the amplitude ratio of primary wave second harmonic wave, and the results of its comparison are used for evaluation. Owing to the experimental features, the experimental nonlinearity result contains system nonlinearity and material nonlinearity. System nonlinearity is that which is unwanted by the user; hence, it acts as an error and interrupts analysis. In this study, a bulk wave mixing technique is implemented in order to minimize the system nonlinearity and obtain the reliable analysis results. The biggest advantage of this technique is that experimental nonlinearity contains less system nonlinearity than that for the conventional nonlinear ultrasonic technique. Theoretical and experimental verifications are performed in this study. By comparing the results of the bulk wave mixing technique with those of the conventional technique, the strengths, weaknesses, and application validity of the bulk wave mixing technique are determined.

  4. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  5. The Effectiveness of Capital Budgeting Techniques in Evaluating ...

    African Journals Online (AJOL)

    DR Nneka

    evaluating the profitability of a project are- pay-back, accounting rate of return, net ... is called financial assets investment, and the technique for evaluating the feasibility of ..... The fundamental theory of share values is based on DCF principles.

  6. Novel Experimental Techniques to Investigate Wellbore Damage Mechanisms

    Science.gov (United States)

    Choens, R. C., II; Ingraham, M. D.; Lee, M.; Dewers, T. A.

    2017-12-01

    A new experimental technique with unique geometry is presented investigating deformation of simulated boreholes using standard axisymmetric triaxial deformation equipment. The Sandia WEllbore SImulation, SWESI, geometry, uses right cylinders of rock 50mm in diameter and 75mm in length. A 11.3mm hole is drilled perpendicular to the axis of the cylinder in the center of the sample to simulate a borehole. The hole is covered with a solid metal cover, and sealed with polyurethane. The metal cover can be machined with a high-pressure port to introduce different fluid chemistries into the borehole at controlled pressures. Samples are deformed in a standard load frame under confinement, allowing for a broad range of possible stresses, load paths, and temperatures. Experiments in this study are loaded to the desired confining pressure, then deformed at a constant axial strain rate or 10-5 sec-1. Two different suites of experiments are conducted in this study on sedimentary and crystalline rock types. The first series of experiments are conducted on Mancos Shale, a finely laminated transversely isotropic rock. Samples are cored at three different orientations to the laminations. A second series of experiments is conducted on Sierra White granite with different fluid chemistries inside the borehole. Numerical modelling and experimental observations including CT-microtomography demonstrate that stresses are concentrated around the simulated wellbore and recreate wellbore deformation mechanisms. Borehole strength and damage development is dependent on anisotropy orientation and fluid chemistry. Observed failure geometries, particularly for Mancos shale, can be highly asymmetric. These results demonstrate uncertainties in in situ stresses measurements using commonly-applied borehole breakout techniques in complicated borehole physico-chemical environments. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering

  7. Instrumentation, computer software and experimental techniques used in low-frequency internal friction studies at WNRE

    International Nuclear Information System (INIS)

    Sprugmann, K.W.; Ritchie, I.G.

    1980-04-01

    A detailed and comprehensive account of the equipment, computer programs and experimental methods developed at the Whiteshell Nuclear Research Estalbishment for the study of low-frequency internal friction is presented. Part 1 describes the mechanical apparatus, electronic instrumentation and computer software, while Part II describes in detail the laboratory techniques and various types of experiments performed together with data reduction and analysis. Experimental procedures for the study of internal friction as a function of temperature, strain amplitude or time are described. Computer control of these experiments using the free-decay technique is outlined. In addition, a pendulum constant-amplitude drive system is described. (auth)

  8. Development of material balance evaluation technique(2)

    International Nuclear Information System (INIS)

    Lee, Byung Doo

    2000-06-01

    IAEA considers that the evaluation on material balance is one of the important activities for detecting the diversion of nuclear materials as well as measurement uncertainties and measurement bias. Nuclear material accounting reports, the results of DA and NDA, the summarized lists of material stratified by inspector are necessary for the material balance evaluation. In this report, the concepts and evaluation methods of material balance evaluation such as the estimation techniques of random and systematic errors, MUF, D and MUF-D are described. As a conclusion, it is possible for national inspection to evaluate the material balance by applying the evaluation methods of the IAEA such as error estimation using operator-inspector paired data, inspector MUF(IMUF) evaluation

  9. Quantitative Evaluation of Defect in Stainless Steel 304 Tube Using Pulsed Eddy Current Technique

    International Nuclear Information System (INIS)

    Nurul Ain Ahmad Latif; Ilham Mukriz Zainal Abidin; Nurul Ain Ahmad Latif; Nordin Jamaludin; Zaredah Hashim; Norhayati Ramli

    2016-01-01

    Pulsed eddy current (PEC) is an advanced non-destructive testing (NDT) technique that operates based on electromagnetic principle. The excitation consists of broad frequency spectrum leading to be a potential in detecting defects that are deeply buried inside the specimen. In this paper, the experiment and simulation were conducted on stainless steel plate 304 fabricated with open surface defects having a different defect depth as an investigation towards the correlation between extracted signal feature and defect depth. Two common features; time to peak and peak value that corresponds to the location depth of defect and size of defect were used for signals analysis and evaluation. The results that acquired through finite element method (FEM) simulation were compared with experimental results for the signals evaluation and defect quantification. (author)

  10. Microbiological evaluation of sludge during an improvement process applying the washing technique (selective pressure)

    International Nuclear Information System (INIS)

    Molina P, Francisco; Gonzalez, Maria Elena; Gonzalez, Luz Catalina

    2001-01-01

    In this investigation, the microbial consortiums were evaluated by using characterization by trophic groups and related groups by their sensibility to oxygen, as well as the specific methanogenic activity (SMA) of an acclimated sludge, starting from an aerobium sludge corning from a residual water treatment plant. Later, the technique of improvement by washing was applicated to this sludge, getting inoculum for the starting of an anaerobic reactor of the kind UASB (treatment reactor). At the same time, a control reactor was operated, inoculated with acclimated sludge. Both reactors were operated during 120 days, using brown sugar as substrate, the experimental phase included dates up to 70 operation days, characterizing the sludge at the end of this period. The SMA was analysed using acetic and formic acids as substrates. The results showed activities between 0,45 and 1,39 g DQO-CH 4 /SSV -d. for both substrates. At the end of the experimental phase of the UASB reactor, the sulphate reducer bacteria from the acetate and the lactate were observed as predominant group, followed by the methanogenic hydrogenophilic bacteria. It is important to notice that, with the application of the sludge washing technique, all the tropic groups were increased, with the exception of the lactate fermentative bacteria

  11. ESR dating: is it still an 'experimental' technique?

    International Nuclear Information System (INIS)

    Skinner, A.R.

    2000-01-01

    Nearly 25 years ago, Motoji Ikeya demonstrated the potential of ESR dating. From a single substance (stalagmitic carbonate) and a single site (Akiyoshi Cavern), the field has grown to include materials from all over the world and time periods from a few thousand years ago to several million years ago. A vigorous program of instrumentation development has increased the precision of measurements as well as opening up new ways of collecting and interpreting spectra. Yet there are still references to ESR dating as an 'experimental' technique, one which cannot be trusted to produce dates that are accurate or precise. This paper discusses areas for which this is true and suggests what should be done to convince skeptics. Other areas for which the evidence suggests that ESR is at least as reliable as 'standard' methods will also be covered

  12. Experimental evaluation of residual stresses produced by plain dents in pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Pascotto, Jorge [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil); Marques, Altino; Fonseca, Maria Cindra [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2009-07-01

    A dent means a permanent plastic deformation of the circular cross-section of the pipe. Dents are potentially danger for structural integrity of onshore and offshore pipelines, because it causes a local stress and strain concentration. It is also expected that residual stresses are introduced by the non-uniform plastic deformation. A plain dent is a dent which causes a smooth change in the curvature of the pipe wall that contains no wall thickness reductions (such as a gouge or a crack) or other defects or imperfections (such as a weld). This work presents an experimental evaluation of residual stresses intensification due to plain dents introduced through the same indentation process, in samples made of the same steel line pipe, commonly used in the pipeline industry. The residual stresses were measured in the longitudinal and circumferential directions in preselected points by X-ray diffraction technique, before indentation. After the samples have been dented, the residual stresses were measured once more at the same points, for comparison. All samples presented a similar behavior of the residual stresses due to induced plain dents, and the X-ray diffraction technique shows itself as an efficient methodology of stress measurement in pipelines. (author)

  13. Momentum--"Evaluating Your Marketing Program: Measuring and Tracking Techniques."

    Science.gov (United States)

    Meservey, Lynne D.

    1990-01-01

    Suggests 10 tracking techniques for evaluating marketing performance. Techniques involve utilization rate, inquiry and source of inquiry tracking, appointment and interview tracking, enrollment conversion, cost per inquiry and per enrollment, retention rate, survey results, and "mystery shopper." (RJC)

  14. Games as Growth and Evaluation Techniques.

    Science.gov (United States)

    Watson, Michael; Allen, Richard

    This paper describes the gaming techniques used at the University of San Francisco Counseling Center to enhance growth and to evaluate the training of professional and paraprofessional staff in the areas of crisis intervention, student services, and self-awareness. Gaming is defined as an exercise in which people either act as themselves or play…

  15. Experimental performance evaluation of two stack sampling systems in a plutonium facility

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.

    1992-04-01

    The evaluation of two routine stack sampling systems at the Z-Plant plutonium facility operated by Rockwell International for USERDA is part of a larger study, sponsored by Rockwell and conducted by Battelle, Pacific Northwest Laboratories, of gaseous effluent sampling systems. The gaseous effluent sampling systems evaluated are located at the main plant ventilation stack (291-Z-1) and at a vessel vent stack (296-Z-3). A preliminary report, which was a paper study issued in April 1976, identified many deficiencies in the existing sampling systems and made recommendations for corrective action. The objectives of this experimental evaluation of those sampling systems were as follows: Characterize the radioactive aerosols in the stack effluents; Develop a tracer aerosol technique for validating particulate effluent sampling system performance; Evaluate the performance of the existing routine sampling systems and their compliance with the sponsor's criteria; and Recommend corrective action where required. The tracer aerosol approach to sampler evaluation was chosen because the low concentrations of radioactive particulates in the effluents would otherwise require much longer sampling times and thus more time to complete this evaluation. The following report describes the sampling systems that are the subject of this study and then details the experiments performed. The results are then presented and discussed. Much of the raw and finished data are included in the appendices

  16. Methods and experimental techniques in computer engineering

    CERN Document Server

    Schiaffonati, Viola

    2014-01-01

    Computing and science reveal a synergic relationship. On the one hand, it is widely evident that computing plays an important role in the scientific endeavor. On the other hand, the role of scientific method in computing is getting increasingly important, especially in providing ways to experimentally evaluate the properties of complex computing systems. This book critically presents these issues from a unitary conceptual and methodological perspective by addressing specific case studies at the intersection between computing and science. The book originates from, and collects the experience of, a course for PhD students in Information Engineering held at the Politecnico di Milano. Following the structure of the course, the book features contributions from some researchers who are working at the intersection between computing and science.

  17. Modelling and Experimental Evaluation of a Static Balancing Technique for a New Horizontally Mounted 3-UPU Parallel Mechanism

    Directory of Open Access Journals (Sweden)

    Maryam Banitalebi Dehkordi

    2012-11-01

    Full Text Available This paper presents the modelling and experimental evaluation of the gravity compensation of a horizontal 3-UPU parallel mechanism. The conventional Newton-Euler method for static analysis and balancing of mechanisms works for serial robots; however, it can become computationally expensive when applied to the analysis of parallel manipulators. To overcome this difficulty, in this paper we propose an approach, based on a Lagrangian method, that is more efficient in terms of computation time. The derivation of the gravity compensation model is based on the analytical computation of the total potential energy of the system at each position of the end-effector. In order to satisfy the gravity compensation condition, the total potential energy of the system should remain constant for all of the manipulator's configurations. Analytical and mechanical gravity compensation is taken into account, and the set of conditions and the system of springs are defined. Finally, employing a virtual reality environment, some experiments are carried out and the reliability and feasibility of the proposed model are evaluated in the presence and absence of the elastic components.

  18. Evaluation of screen-film system quality: physical principles and measurement techniques

    International Nuclear Information System (INIS)

    Borasi, G.; Berardi, P.; Ferretti, P.P.; Piccagli, V.

    1990-01-01

    Comparative evaluation of radiographic filmscreen systems presents several problems from both the theoretical and the experimental point of view. From the theoretical point of view the main difficulties are related to the choice of the parameters best suited to express the 'overall quality' of a system. From the practical point of view the main problem is that to measure some basic quantities (resolution and noise) sophisticated and expensive instruments are required. This paper deals with both these problems. To express image quality we have assumed the signal-to-noise power ration: this index depends in a explicit way on contrast, resolution and noise of the system. The dependence on sensitivity is implicit and was derived using literature data. From a knowledge of the dependence of image quality on sensitivity it is possible to develop an 'overall quality' index which is considered to express the 'technological level' of the systems. In this work some basic phisical quantities (characteristic curve, sensitivity) were evaluated using standard instruments. To measure spatial resolution and noise an inexpensive, PC-based, TV-digitizer system was developed. As an example, both image and overall quality indices were evaluated on three mammographic systems which are typical of the three different 'phases' of the development of this technique

  19. Online laboratory evaluation of seeding-machine application by an acoustic technique

    Energy Technology Data Exchange (ETDEWEB)

    Karimi, H.; Navid, H.; Mahmoudi, A.

    2015-07-01

    Researchers and planter manufacturers have been working closely to develop an automated system for evaluating performance of seeding. In the present study, an innovative use of acoustic signal for laboratory evaluation of seeding-machine application is described. Seed detection technique of the proposed system was based on a rising voltage value that a microphone sensed in each impaction of seeds to a steel plate. Online determining of seed spacing was done with a script which was written in MATLAB software. To evaluate the acoustic system with desired seed spacing, a testing rig was designed. Seeds of wheat, corn and pelleted tomato were used as experimental material. Typical seed patterns were positioned manually on a belt stand with different spacing patterns. When the belt was running, the falling seeds from the end point of the belt impacted to the steel plate, and their acoustic signal was sensed by the microphone. In each impact, data was processed and spacing between the seeds was automatically obtained. Coefficient of determination of gathered data from the belt system and the corresponding seeds spacing measured with the acoustic system in all runs was about 0.98. This strong correlation indicates that the acoustic system worked well in determining the seeds spacing. (Author)

  20. Review of Surgical Techniques of Experimental Renal Transplantation in Rats.

    Science.gov (United States)

    Shrestha, Badri; Haylor, John

    2017-08-01

    Microvascular surgical techniques of renal transplant in rats have evolved over the past 5 decades to achieve successful rat renal transplant; these modifications have included surgical techniques to address the anatomic variations in the renal blood vessels and those to reduce ischemic and operation durations. Here, we review the surgical techniques of renal transplant in rats and evaluate the advantages and disadvantages of individual techniques of vascular and ureteric anastomoses. For this review, we performed a systematic literature search using relevant medical subject heading terms and included appropriate publications in the review. Since the first description of a rat model of renal transplant by Bernard Fisher and his colleagues in 1965, which used end-to-side anastomosis between the renal vein and renal artery to the recipient inferior vena cava and aorta, several vascular and ureteric anastomosis techniques have been modified. Vascular anastomosis techniques now include end-to-end anastomosis, use of donor aortic and inferior vena cava conduits, sleeve and cuff anastomoses, and application of fibrin glue. Likewise, restoration of the urinary tract can now be achieved by direct anastomosis of the donor ureter to the recipient bladder, end-to-end anastomosis between the donor and recipient ureters, and donor bladder cuff to the recipient bladder. There are advantages and disadvantages attributable to individual techniques. The range of vascular and ureteric anastomosis techniques that has emerged reflects the need for mastering more than one technique to suit the vascular anatomy of individual animals and to reduce operating time for achieving successful outcomes after renal transplant.

  1. Evaluating inhaler use technique in COPD patients

    Directory of Open Access Journals (Sweden)

    Pothirat C

    2015-07-01

    Full Text Available Chaicharn Pothirat, Warawut Chaiwong, Nittaya Phetsuk, Sangnual Pisalthanapuna, Nonglak Chetsadaphan, Woranoot Choomuang Division of Pulmonary, Critical Care and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand Background: Poor inhalation techniques are associated with decreased medication delivery and poor disease control in chronic obstructive pulmonary disease (COPD. The purpose of this study was to evaluate techniques for using inhaler devices in COPD patients.Methods: A prospective cross-sectional study was conducted to assess patient compliance with correct techniques for using inhaler devices across four regimens, ie, the pressurized metered-dose inhaler (pMDI, the pMDI with a spacer, the Accuhaler®, and the Handihaler®. The percentage of compliance with essential steps of correct device usage for each regimen was recorded without prior notification when COPD patients presented for a routine visit, and 1 month after receiving face-to-face training. We compared the percentage of compliance between the devices and risk factors related to incorrect techniques using logistic regression analysis. Percentage of patient compliance with correct techniques was compared between the two visits using the chi-square test. Statistical significance was set at P<0.05.Results: A total of 103 COPD patients (mean age 71.2±9.2 years, males 64.1%, low education level 82.5%, and percent predicted forced expiratory volume in 1 second 51.9±22.5 were evaluated. Seventy-seven patients (74.8% performed at least one step incorrectly. Patients using the Handihaler had the lowest compliance failure (42.5%, and the odds ratio for failure with the other devices compared with the Handihaler were 4.6 (95% confidence interval [CI] 1.8–11.8 for the pMDI, 3.1 (95% CI 1.2–8.2 for the pMDI with a spacer, and 2.4 (95% CI 1.1–5.2 for the Accuhaler. Low education level was the single most important factor related

  2. Evaluation of Inhaler Techniques Among Asthma Patients Seen in ...

    African Journals Online (AJOL)

    hanumantp

    Drug inhalation is an important and a common mode of .... to evaluate the use of inhaler technique among asthma patients in a .... The median duration of the use of the inhalers is 24 ..... Scalabrini A, Cukier A. Incorrect application technique of.

  3. Evaluation of stabilization-solidification techniques

    International Nuclear Information System (INIS)

    Goubier, R.

    1989-01-01

    This paper reports that among the techniques applied to treat polluting residue in France for the past ten years has been the mixing of pollutants with reactive agents in order to fix the contaminants and to give them a solid consistency. The first applications of these stabilization/solidification processes occurred in 1978 in the treatment of oil residues from the AMOCO CADIZ spill. They have also been used for the treatment of a mayor dump site for petroleum residues, for the disposal of mineral sludges of a detoxication plant, and for the rehabilitation of sites contaminated by various industrial residues, specially acid tars generated by oil refining plants. Although from the beginning these techniques appeared to be able to transform filthy lagoons into solid and apparently safe areas, it was necessary to evaluate their efficiency and to determine the conditions and limits of application

  4. Experimental study of biotin-avidin pretargeting technique for anti-CEA McAb radioimmunoimaging

    International Nuclear Information System (INIS)

    Sun Jianzhong; Zhu Chengmo; Guan Liang; Li Biao; Zhang Jixian; Shi Ailan; Zhang Suyin

    1996-01-01

    Biotin-avidin pretargeting technique was used in promoting the diagnostic efficacy of anti-CEA McAb radioimmunoimaging. CEA McAb was conjugated with biotin McAb (B-McAb), streptavidin (SA) was labeled with 131 I ( 131 I-SA) and DTPA-biotin with 111 In( 111 In-DTPA-B). Experimental human colonic tumor bearing nude mice were used. Two step method: B-McAb was preinjected, followed by 131 I SA 48h later, 24, 48, 96 and 120 h postinjection, γ-imaging and biodistribution were studied. Three step method: B-McAb was preinjected, followed by cold SA 24h later and 111 In-DTPA-B another 24h later. 2,6,24 and 48h postinjection, γ-imaging and biodistribution were also studied. Two step method: T/NT of all organs in experimental group was significantly increased compared with controls. The blood T/NT in experimental group and control group at 24 and 120h was 1.11:0.42 and 8.58:3.51, respectively. Tumor % ID/g in all organs slightly decreased compared with direct group. In γ-imaging radioactivity has been accumulated in tumor site as early as 24h, while only slightly visualized or non-visualized in controls. Three step method: in experimental group the blood T/NT reached 4.19 at 2 h, whereas all was < 1.37 at each phase of controls, the T/NT of all organs was also higher in experimental grouped than in controls. The tumor % ID/g in experimental group was 9.72% at 2h and 3.65% at 48h whereas % ID/g in controls in all phases was <3.07. The tumor clearly visualized at 2h and clearer at 48h in γ-imaging. In controls, the tumor was slightly visualized also to early stage, but faded away later on. Biotin-avidin pretargeting technique can elevate the T/NT ratio and decrease the blood background. Early imaging was obtained with better imaging quality

  5. Ethnographic Techniques in Educational Evaluation: An Illustration.

    Science.gov (United States)

    Fetterman, David

    1980-01-01

    Describes the ethnographic component of a multidisciplinary evaluation, conducted by the RMC Research Corporation, of the Career Intern Program for dropouts. Includes discussion of participant observations, interviewing techniques, triangulation, unobtrusive measures, data recording, and equipment. (Part of a theme issue entitled…

  6. Evaluation of miniature tension specimen fabrication techniques and performance

    International Nuclear Information System (INIS)

    Hamilton, M.L.; Blotter, M.A.; Edwards, D.J.

    1993-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed

  7. Evaluation of miniature tensile specimen fabrication techniques and performance

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, M.L. (Pacific Northwest Lab., Richland, WA (United States)); Blotter, M.A.; Edwards, D.J. (Missouri Univ., Rolla, MO (United States))

    1992-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical, milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed.

  8. Evaluation of miniature tensile specimen fabrication techniques and performance

    International Nuclear Information System (INIS)

    Hamilton, M.L.; Blotter, M.A.; Edwards, D.J.

    1992-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical, milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed

  9. Restoring accommodation: surgical technique and preliminary evaluation in rabbits

    Science.gov (United States)

    Tahi, Hassan; Chapon, Pascal F.; Hamaoui, Marie; Lee, William E.; Holden, Brien; Parel, Jean-Marie A.

    1999-06-01

    Purpose. To evaluate an innovative surgical technique for phaco-ersatz, a cataract surgery designed to restore accommodation. Techniques for very small capsulorhexis as well as the refilling procedure were developed. This study evaluates the feasibility and reproducibility of the surgical technique. Methods. The right eye of 8 NZW rabbits (~ 2 Kg) were operated following the ARVO Statements for the Use of Animals in Ophthalmic and Vision Research. The surgery is begun by making a small peripheral capsulorhexis of about 1 mm using. The lens content is then removed. The lens is then refilled with a novel in situ polymerizable gel and the corneal incision is closed using one 10/0 Nylon interrupted stitch. Results. The capsulorhexis technique was succesfully performed and reproducible in all animals. The average size of the capsulorhexis opening was 1. 2 mm (+/-0.14). Lens material removal and refilling of the capsular bag with an in situ polymerizable material was also performed in each trial study. Conclusion. This surgical technique seemed feasible and reproducible.

  10. Sensitivity analysis of hybrid thermoelastic techniques

    Science.gov (United States)

    W.A. Samad; J.M. Considine

    2017-01-01

    Stress functions have been used as a complementary tool to support experimental techniques, such as thermoelastic stress analysis (TSA) and digital image correlation (DIC), in an effort to evaluate the complete and separate full-field stresses of loaded structures. The need for such coupling between experimental data and stress functions is due to the fact that...

  11. Criteria of the validation of experimental and evaluated covariance data

    International Nuclear Information System (INIS)

    Badikov, S.

    2008-01-01

    The criteria of the validation of experimental and evaluated covariance data are reviewed. In particular: a) the criterion of the positive definiteness for covariance matrices, b) the relationship between the 'integral' experimental and estimated uncertainties, c) the validity of the statistical invariants, d) the restrictions imposed to correlations between experimental errors, are described. Applying these criteria in nuclear data evaluation was considered and 4 particular points have been examined. First preserving positive definiteness of covariance matrices in case of arbitrary transformation of a random vector was considered, properties of the covariance matrices in operations widely used in neutron and reactor physics (splitting and collapsing energy groups, averaging the physical values over energy groups, estimation parameters on the basis of measurements by means of generalized least squares method) were studied. Secondly, an algorithm for comparison of experimental and estimated 'integral' uncertainties was developed, square root of determinant of a covariance matrix is recommended for use in nuclear data evaluation as a measure of 'integral' uncertainty for vectors of experimental and estimated values. Thirdly, a set of statistical invariants-values which are preserved in statistical processing was presented. And fourthly, the inequality that signals a correlation between experimental errors that leads to unphysical values is given. An application is given concerning the cross-section of the (n,t) reaction on Li 6 with a neutron incident energy comprised between 1 and 100 keV

  12. Integration of computational modeling and experimental techniques to design fuel surrogates

    DEFF Research Database (Denmark)

    Choudhury, H.A.; Intikhab, S.; Kalakul, Sawitree

    2017-01-01

    performance. A simplified alternative is to develop surrogate fuels that have fewer compounds and emulate certain important desired physical properties of the target fuels. Six gasoline blends were formulated through a computer aided model based technique “Mixed Integer Non-Linear Programming” (MINLP...... Virtual Process-Product Design Laboratory (VPPD-Lab) are applied onto the defined compositions of the surrogate gasoline. The aim is to primarily verify the defined composition of gasoline by means of VPPD-Lab. ρ, η and RVP are calculated with more accuracy and constraints such as distillation curve...... and flash point on the blend design are also considered. A post-design experiment-based verification step is proposed to further improve and fine-tune the “best” selected gasoline blends following the computation work. Here, advanced experimental techniques are used to measure the RVP, ρ, η, RON...

  13. An anonymization technique using intersected decision trees

    Directory of Open Access Journals (Sweden)

    Sam Fletcher

    2015-07-01

    Full Text Available Data mining plays an important role in analyzing the massive amount of data collected in today’s world. However, due to the public’s rising awareness of privacy and lack of trust in organizations, suitable Privacy Preserving Data Mining (PPDM techniques have become vital. A PPDM technique provides individual privacy while allowing useful data mining. We present a novel noise addition technique called Forest Framework, two novel data quality evaluation techniques called EDUDS and EDUSC, and a security evaluation technique called SERS. Forest Framework builds a decision forest from a dataset and preserves all the patterns (logic rules of the forest while adding noise to the dataset. We compare Forest Framework to its predecessor, Framework, and another established technique, GADP. Our comparison is done using our three evaluation criteria, as well as Prediction Accuracy. Our experimental results demonstrate the success of our proposed extensions to Framework and the usefulness of our evaluation criteria.

  14. Evaluating Local Primary Dendrite Arm Spacing Characterization Techniques Using Synthetic Directionally Solidified Dendritic Microstructures

    Science.gov (United States)

    Tschopp, Mark A.; Miller, Jonathan D.; Oppedal, Andrew L.; Solanki, Kiran N.

    2015-10-01

    Microstructure characterization continues to play an important bridge to understanding why particular processing routes or parameters affect the properties of materials. This statement certainly holds true in the case of directionally solidified dendritic microstructures, where characterizing the primary dendrite arm spacing is vital to developing the process-structure-property relationships that can lead to the design and optimization of processing routes for defined properties. In this work, four series of simulations were used to examine the capability of a few Voronoi-based techniques to capture local microstructure statistics (primary dendrite arm spacing and coordination number) in controlled (synthetically generated) microstructures. These simulations used both cubic and hexagonal microstructures with varying degrees of disorder (noise) to study the effects of length scale, base microstructure, microstructure variability, and technique parameters on the local PDAS distribution, local coordination number distribution, bulk PDAS, and bulk coordination number. The Voronoi tesselation technique with a polygon-side-length criterion correctly characterized the known synthetic microstructures. By systematically studying the different techniques for quantifying local primary dendrite arm spacings, we have evaluated their capability to capture this important microstructure feature in different dendritic microstructures, which can be an important step for experimentally correlating with both processing and properties in single crystal nickel-based superalloys.

  15. Tribological evaluation for experimental design Al_2O_3 obtained via low pressure injection moulding (LPIM)

    International Nuclear Information System (INIS)

    Dotta, A.L.B.; Costa, C.A.; Farias, M.C.M.; Cunha, M.A da

    2016-01-01

    This work represents the tribological study of Al_2O_3 obtained by LPIM using the experimental design technique to evaluate the interaction of the tribological parameters with the friction and wear. The LPIM process was performed at 90 °C for 24 h. The average friction coefficient for the factorial experimental design varied significantly with the load and the speed when Al_2O_3 was tested with the steel counter body. In general, the wear coefficient was lower for the tribological pair Al_2O_3-steel, in which occurred the formation of an iron oxide tribofilm on the surface. As for the Al_2O_3-Al_2O_3 pair, an intergranular fracture of the surface occurred, in addition to the presence of material adhered on the tracks. (author)

  16. Minimizing Experimental Error in Thinning Research

    Science.gov (United States)

    C. B. Briscoe

    1964-01-01

    Many diverse approaches have been made prescribing and evaluating thinnings on an objective basis. None of the techniques proposed hasbeen widely accepted. Indeed. none has been proven superior to the others nor even widely applicable. There are at least two possible reasons for this: none of the techniques suggested is of any general utility and/or experimental error...

  17. Experimental Study on Indoor Air Cleaning Technique of Nano-Titania Catalysis Under Plasma Discharge

    International Nuclear Information System (INIS)

    Gao Deli; Yang Xuechang; Zhou Fei; Wu Yuhuang

    2008-01-01

    In this study, a new technique of air cleaning by plasma combined with catalyst was proposed, which consisted of electrostatic precipitation, volatile organic compounds (VOCs) decomposition and sterilization. A novel indoor air purifier based on this technique was adopted. The experimental results showed that formaldehyde decomposition by the plasma-catalyst hybrid system was more efficient than that by plasma only. Positive discharge was better than negative discharge in formaldehyde removal. Meanwhile, the outlet concentration of ozone byproduct was effectively reduced by the nano-titania catalyst.

  18. Evaluation of turbulence measurement techniques from a single Doppler lidar

    Directory of Open Access Journals (Sweden)

    T. A. Bonin

    2017-08-01

    Full Text Available Measurements of turbulence are essential to understand and quantify the transport and dispersal of heat, moisture, momentum, and trace gases within the planetary boundary layer (PBL. Through the years, various techniques to measure turbulence using Doppler lidar observations have been proposed. However, the accuracy of these measurements has rarely been validated against trusted in situ instrumentation. Herein, data from the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA are used to verify Doppler lidar turbulence profiles through comparison with sonic anemometer measurements. For 17 days at the end of the experiment, a single scanning Doppler lidar continuously cycled through different turbulence measurement strategies: velocity–azimuth display (VAD, six-beam scans, and range–height indicators (RHIs with a vertical stare.Measurements of turbulence kinetic energy (TKE, turbulence intensity, and stress velocity from these techniques are compared with sonic anemometer measurements at six heights on a 300 m tower. The six-beam technique is found to generally measure turbulence kinetic energy and turbulence intensity the most accurately at all heights (r2  ≈  0.78, showing little bias in its observations (slope of  ≈  0. 95. Turbulence measurements from the velocity–azimuth display method tended to be biased low near the surface, as large eddies were not captured by the scan. None of the methods evaluated were able to consistently accurately measure the shear velocity (r2 =  0.15–0.17. Each of the scanning strategies assessed had its own strengths and limitations that need to be considered when selecting the method used in future experiments.

  19. Experimental evaluation of different mixing promoter for nuclear fuel element by means of a new thermal tracing technique

    International Nuclear Information System (INIS)

    Silin, Nicolas; Juanico, Luis; Delmastro, Dario

    2004-01-01

    In this work a new experimental method is used to experimentally evaluate the performance of different appendages promoting the turbulent mixing between the coupled subchannels of nuclear fuel elements.The method used will be introduced in another presentation and consists in the generation and measurement of small thermal traces in the refrigerating water flow between the fuel rods.Because it is suitable for heterogeneous and compact subchannels (as Argentinean fuels) with high water flows in simple and affordable tests at atmospheric pressure, this new method is specially well suited for the design of fuel elements, while it offers advantages over other methods of mixing measurement.The experiments carried out on a small test section proved that the buttons brazed to the fuel rods (similar to the 'turbulence promoters' of the Canflex fuel) had an excellent thermohydraulic performance as compared to different mixing vane designs studied.The thermal traces method developed has shown its potential as a thermohydraulic design tool for the development of advanced nuclear fuels, that eventually incorporate mixing promoter elements. In the case of CARA, and as it includes spacer grids, it could be possible to use them to incorporate these elements without the need of brazing them to the rods (as is the case in Canflex), and therefore without penalizing its integrity [es

  20. Progress in nuclear measuring and experimental techniques by application of microelectronics. 1

    International Nuclear Information System (INIS)

    Meiling, W.

    1984-01-01

    In the past decade considerable progress has been made in nuclear measuring and experimental techniques by developing position-sensitive detector systems and widely using integrated circuits and microcomputers for data acquisition and processing as well as for automation of measuring processes. In this report which will be published in three parts those developments are reviewed and demonstrated on selected examples. After briefly characterizing microelectronics, the use of microelectronic elements for radiation detectors is reviewed. (author)

  1. Usability evaluation techniques in mobile commerce applications: A systematic review

    Science.gov (United States)

    Hussain, Azham; Mkpojiogu, Emmanuel O. C.

    2016-08-01

    Obviously, there are a number of literatures concerning the usability of mobile commerce (m-commerce) applications and related areas, but they do not adequately provide knowledge about usability techniques used in most of the empirical usability evaluation for m-commerce application. Therefore, this paper is aimed at producing the usability techniques frequently used in the aspect of usability evaluation for m-commerce applications. To achieve the stated objective, systematic literature review was employed. Sixty seven papers were downloaded in usability evaluation for m-commerce and related areas; twenty one most relevant studies were selected for review in order to extract the appropriate information. The results from the review shows that heuristic evaluation, formal test and think aloud methods are the most commonly used methods in m-commerce application in comparison to cognitive walkthrough and the informal test methods. Moreover, most of the studies applied control experiment (33.3% of the total studies); other studies that applied case study for usability evaluation are 14.28%. The results from this paper provide additional knowledge to the usability practitioners and research community for the current state and use of usability techniques in m-commerce application.

  2. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Schouten, Martijn G. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); University Medical Centre Nijmegen, Department of Radiology, Nijmegen (Netherlands); Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Rothgang, Eva [Pattern Recognition Lab, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Center for Applied Medical Imaging, Siemens Corporate Research (Germany); Center for Applied Medical Imaging, Siemens Corporate Research, Baltimore, MD (United States); Misra, Sarthak [University of Twente, MIRA-Institute of Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2012-02-15

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  3. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    International Nuclear Information System (INIS)

    Schouten, Martijn G.; Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J.; Rothgang, Eva; Misra, Sarthak

    2012-01-01

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  4. Experimental study of natural two-phase flow circulation using a visualization technique

    International Nuclear Information System (INIS)

    Vinhas, Pedro A.M.; Su, Jian

    2013-01-01

    This paper presents an experimental study of natural two-phase flow in a circuit that simulates, on a smaller scale, a typical residual heat removal system of passive reactors APWR (Advanced Pressurized Water Reactor). The circuit was formed by a heater, a heat exchanger and piping. The experimental study was the application of a visualization technique, using a high speed camera, for measuring the size and speed of vapor bubbles generated in the heater with different power heating. The camera was positioned in the central region of the pipe connecting the heater to the heat exchanger, where there is a clear passage. The flow of images were processed and analyzed using commercial software that allowed the determination of the length and velocity of the bubbles. The results were then compared with correlations available in literature

  5. An experimental system for coiled tubing partial underbalanced drilling (CT-PUBD) technique

    Science.gov (United States)

    Shi, H. Z.; Ji, Z. S.; Zhao, H. Q.; Chen, Z. L.; Zhang, H. Z.

    2018-05-01

    To improve the rate of penetration (ROP) in hard formations, a new high-speed drilling technique called Coiled Tubing Partial Underbalanced Drilling (CT-PUBD) is proposed. This method uses a rotary packer to realize an underbalanced condition near the bit by creating a micro-annulus and an overbalanced condition at the main part of the annulus. A new full-scale laboratory experimental system is designed and set up to study the hydraulic characteristics and drilling performance of this method. The system is composed of a drilling system, circulation system, and monitor system, including three key devices, namely, cuttings discharge device, rotary packer, and backflow device. The experimental results showed that the pressure loss increased linearly with the flow rate of the drilling fluid. The high drilling speed of CT-PUBD proved it a better drilling method than the conventional drilling. The experimental system may provide a fundamental basis for the research of CT-PUBD, and the results proved that this new method is feasible in enhancing ROP and guaranteeing the drilling safety.

  6. Surface science techniques

    CERN Document Server

    Bracco, Gianangelo

    2013-01-01

    The book describes the experimental techniques employed to study surfaces and interfaces. The emphasis is on the experimental method. Therefore all chapters start with an introduction of the scientific problem, the theory necessary to understand how the technique works and how to understand the results. Descriptions of real experimental setups, experimental results at different systems are given to show both the strength and the limits of the technique. In a final part the new developments and possible extensions of the techniques are presented. The included techniques provide microscopic as well as macroscopic information. They cover most of the techniques used in surface science.

  7. An evaluation of alternative reactor vessel cutting technologies for the experimental boiling water reactor at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Boing, L.E.; Henley, D.R.; Manion, W.J.; Gordon, J.W.

    1989-12-01

    Metal cutting techniques that can be used to segment the reactor pressure vessel of the Experimental Boiling Water Reactor (EBWR) at Argonne National Laboratory (ANL) have been evaluated by Nuclear Energy Services. Twelve cutting technologies are described in terms of their ability to perform the required task, their performance characteristics, environmental and radiological impacts, and cost and schedule considerations. Specific recommendations regarding which technology should ultimately be used by ANL are included. The selection of a cutting method was the responsibility of the decommissioning staff at ANL, who included a relative weighting of the parameters described in this document in their evaluation process. 73 refs., 26 figs., 69 tabs

  8. An evaluation of alternative reactor vessel cutting technologies for the experimental boiling water reactor at Argonne National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Boing, L.E.; Henley, D.R. (Argonne National Lab., IL (USA)); Manion, W.J.; Gordon, J.W. (Nuclear Energy Services, Inc., Danbury, CT (USA))

    1989-12-01

    Metal cutting techniques that can be used to segment the reactor pressure vessel of the Experimental Boiling Water Reactor (EBWR) at Argonne National Laboratory (ANL) have been evaluated by Nuclear Energy Services. Twelve cutting technologies are described in terms of their ability to perform the required task, their performance characteristics, environmental and radiological impacts, and cost and schedule considerations. Specific recommendations regarding which technology should ultimately be used by ANL are included. The selection of a cutting method was the responsibility of the decommissioning staff at ANL, who included a relative weighting of the parameters described in this document in their evaluation process. 73 refs., 26 figs., 69 tabs.

  9. Evaluation of Conservation Tillage Techniques for Maize Production ...

    African Journals Online (AJOL)

    conservation tillage techniques and evaluate the impacts of the system on ... biological soil manipulation to optimize conditions for seed germination, emergence and ..... planting and weeding operations as total expense and sales from maize ...

  10. Comparison of activation cross section measurements and experimental techniques for fusion reactor technology. Summary report of the IAEA specialists' meeting held in St. Petersburg, Russia, 7 to 9 September 1994

    International Nuclear Information System (INIS)

    Pashchenko, A.B.

    1995-02-01

    The report contains the Summary of the IAEA Specialists' Meeting on ''Comparison of Activation Cross Section Measurements and Experimental Techniques for Fusion Reactor Technology''. The meeting was organized by the IAEA Nuclear Data Section (NDS) with co-operation and assistance of local organizers from the V.G. Khlopin Radium Institute, KRI, and held in St. Petersburg, Russia, from 7 to 9 September 1994. The aim of the meeting was to discuss and evaluate the preliminary results of the researches carried out in the framework of the international programme on Comparison of Activation Cross Section Measurements and Experimental Techniques for Fusion Reactor Technology coordinated by the IAEA Nuclear Data Section and to identify further measurements and actions of participating laboratories. The detailed conclusions and recommendations of the meeting are presented in Attachment 1 of the summary report. It was confirmed that for further comparison of experimental techniques the experimental groups at JAERI (Tokai, Japan), KRI (St. Petersburg, Russia), IPPE (Obninsk, Russia) and IEP (Debrecen, Hungary) will join in a collaborative program on comparing their measurement techniques and do measurements for reactions where discrepancies between their previous measurements exist. In cases where the JAERI results are the only existing data or deviate strongly from previous measurements, collaboration between KRI, IEP, IPPE and other institutions can consider measurements of these cross sections in order to clarify the situation. (author)

  11. Comparison of techniques used for functional evaluation of pelvic floor muscles

    Directory of Open Access Journals (Sweden)

    Christiane Kelen Lucena da Costa

    2017-06-01

    Full Text Available Objective: To identify and discuss techniques for evaluation of pelvic floor muscles (PFM focusing on the most used and accessible techniques in health care. Methods: This is a quantitative exploratory and descriptive applied research. Data were collected from March to June 2016 at a higher education institution in the city of João Pessoa, Paraíba, Brazil. Initially, 31 healthy young women were submitted to pelvic floor evaluation using the following methods: PERFECT, vaginal cones, and perineometry using Perine and Peritron. The participants then performed exercises to strengthen PFM. The variables measured by the different methods were also recorded 30 and 60 days after the start of the program. ANOVA was used for repeated measures and Spearman's correlation test was used for the evaluation instruments with significance set at 5%. Results: The functional evaluation using all the methods was adequate in the PFM evaluation. In the digital palpation (PERFECT, the endurance response (E was positively correlated to Perina (rho=0.688 and vaginal cones (rho=0.571, and muscle strength (P was positively correlated to the Peritron technique (rho=0.506. Conclusion: There are several ways to evaluate PFM function and all of them provide sensory feedback to the patient. Given the low costs of digital palpation, the introduction of this technique into women's health services is likely to improve women's quality of life.

  12. Biofilms and mechanics: a review of experimental techniques and findings

    International Nuclear Information System (INIS)

    Gordon, Vernita D; Davis-Fields, Megan; Kovach, Kristin; Rodesney, Christopher A

    2017-01-01

    Biofilms are developmentally-dynamic communities of sessile microbes that adhere to each other and, often, to other structures in their environment. The cohesive mechanical forces binding microbes to each other confer mechanical and structural stability on the biofilm and give rise to biofilm viscoelasticity. The adhesive mechanical forces binding microbes to other structures in their environment can promote biofilm initiation and mechanosensing that leads to changes in biological activity. Thus, physical mechanics is intrinsic to characteristics that distinguish biofilms from free-swimming or free-floating microbes in liquid culture. However, very little is known about the specifics of what mechanical traits characterize different types of biofilms at different stages of development. Even less is known about how mechanical inputs impact microbial biology and how microbes can adjust their mechanical coupling to, and interaction with, their environment. These knowledge gaps arise, in part, from the challenges associated with experimental measurements of microbial and biofilm biomechanics. Here, we review extant experimental techniques and their most-salient findings to date. At the end of this review we indicate areas where significant advances in the state-of-the art are heading. (topical review)

  13. Biofilms and mechanics: a review of experimental techniques and findings

    Science.gov (United States)

    Gordon, Vernita D.; Davis-Fields, Megan; Kovach, Kristin; Rodesney, Christopher A.

    2017-06-01

    Biofilms are developmentally-dynamic communities of sessile microbes that adhere to each other and, often, to other structures in their environment. The cohesive mechanical forces binding microbes to each other confer mechanical and structural stability on the biofilm and give rise to biofilm viscoelasticity. The adhesive mechanical forces binding microbes to other structures in their environment can promote biofilm initiation and mechanosensing that leads to changes in biological activity. Thus, physical mechanics is intrinsic to characteristics that distinguish biofilms from free-swimming or free-floating microbes in liquid culture. However, very little is known about the specifics of what mechanical traits characterize different types of biofilms at different stages of development. Even less is known about how mechanical inputs impact microbial biology and how microbes can adjust their mechanical coupling to, and interaction with, their environment. These knowledge gaps arise, in part, from the challenges associated with experimental measurements of microbial and biofilm biomechanics. Here, we review extant experimental techniques and their most-salient findings to date. At the end of this review we indicate areas where significant advances in the state-of-the art are heading.

  14. Design and performance evaluations of generic programming techniques in a R and D prototype of Geant4 physics

    Energy Technology Data Exchange (ETDEWEB)

    Pia, M G; Saracco, P; Sudhakar, M [INFN Sezione di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Zoglauer, A [University of California at Berkeley, Berkeley, CA 94720-7450 (United States); Augelli, M [CNES, 18 Av. Edouard Belin, 31401 Toulouse (France); Gargioni, E [University Medical Center Hamburg-Eppendorf, D-20246 Hamburg (Germany); Kim, C H [Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul, 133-791 (Korea, Republic of); Quintieri, L [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi 40, I-00044 Frascati (Italy); Filho, P P de Queiroz; Santos, D de Souza [IRD, Av. Salvador Allende, s/n. 22780-160, Rio de Janeiro, RJ (Brazil); Weidenspointner, G [MPI fuer extraterrestrische Physik Postfach 1603, D-85740 Garching (Germany); Begalli, M, E-mail: mariagrazia.pia@ge.infn.i [UERJ, R. Sao Francisco Xavier, 524. 20550-013, Rio de Janeiro, RJ (Brazil)

    2010-04-01

    A R and D project has been recently launched to investigate Geant4 architectural design in view of addressing new experimental issues in HEP and other related physics disciplines. In the context of this project the use of generic programming techniques besides the conventional object oriented is investigated. Software design features and preliminary results from a new prototype implementation of Geant4 electromagnetic physics are illustrated. Performance evaluations are presented. Issues related to quality assurance in Geant4 physics modelling are discussed.

  15. Measuring and Analyzing the Scholarly Impact of Experimental Evaluation Initiatives

    DEFF Research Database (Denmark)

    Angelini, Marco; Ferro, Nicola; Larsen, Birger

    2014-01-01

    Evaluation initiatives have been widely credited with contributing highly to the development and advancement of information access systems, by providing a sustainable platform for conducting the very demanding activity of comparable experimental evaluation in a large scale. Measuring the impact...

  16. Experimental Evaluation of Lightweight AAC Masonry Wall Prisms with Ferrocement Layers in Compression and Flexure

    KAUST Repository

    Abdel Mooty, Mohamed; Hendam, Ahmed; Fahmy, Ezzat; Abou Zeid, Mohamed; Haroun, Medhat

    2012-01-01

    An experimental program is designed to evaluate the performance of lightweight autoclaved aerated concrete masonry wall strengthened using ferrocement layers, in a sandwich structure, under in-plane compression and out-of-plane bending. The 25 mm thick ferrocement mortar is reinforced with steel welded wire mesh of 1 mm diameters at 15 mm spacing. Different types of shear connectors are used to evaluate their effect on failure loads. The effect of different design parameters on the wall strength are considered including wall thickness, mortar strength, and type and distribution of shear connectors. A total of 20 prisms are tested in compression and 5 prisms are tested under bending. The proposed ferrocement strengthening technique is easy to apply on existing wall system and results in significant strength and stiffness enhancement of the tested wall specimens. © (2012) Trans Tech Publications.

  17. Experimental Evaluation of Lightweight AAC Masonry Wall Prisms with Ferrocement Layers in Compression and Flexure

    KAUST Repository

    Abdel Mooty, Mohamed

    2012-05-01

    An experimental program is designed to evaluate the performance of lightweight autoclaved aerated concrete masonry wall strengthened using ferrocement layers, in a sandwich structure, under in-plane compression and out-of-plane bending. The 25 mm thick ferrocement mortar is reinforced with steel welded wire mesh of 1 mm diameters at 15 mm spacing. Different types of shear connectors are used to evaluate their effect on failure loads. The effect of different design parameters on the wall strength are considered including wall thickness, mortar strength, and type and distribution of shear connectors. A total of 20 prisms are tested in compression and 5 prisms are tested under bending. The proposed ferrocement strengthening technique is easy to apply on existing wall system and results in significant strength and stiffness enhancement of the tested wall specimens. © (2012) Trans Tech Publications.

  18. Laser-welded ureteral anastomoses: experimental studies with three techniques.

    Science.gov (United States)

    Gürpinar, T; Gürer, S; Kattan, M W; Wang, L; Griffith, D P

    1996-01-01

    Tissue welding with laser energy is a new technique for reconstructive surgery. The potential advantages of laser welding are (a) lack of foreign body reaction, (b) decreased operative time, (c) less tissue manipulation, and (d) effective union of tissues equivalent to sutured anastomoses. We have performed ureteral anastomoses in adult mongrel dogs using a KTP 532 nm laser at an intensity of 1.4 W. Multiple "spot welds" of 1-s duration were utilized in a single layer anastomosis. Laser-welded anastomoses were performed with and without protein solder (33% and 50% human albumin) and were compared to sutured anastomoses. The laser-welded anastomoses required less operative time and provided bursting pressure levels similar to those of traditional sutured anastomoses. There was no advantage or disadvantage to the addition of human albumin as a solder in these experimental studies.

  19. Evaluating Eye Drop Instillation Technique and Its Determinants in Glaucoma Patients

    Directory of Open Access Journals (Sweden)

    Xinbo Gao

    2018-01-01

    Full Text Available Aim. To evaluate eye drop instillation technique and to explore its determinants in glaucoma patients. Methods. One hundred and thirteen patients diagnosed with glaucoma and self-administering topical antiglaucoma eye drops for at least 1 month were evaluated. All patients instilled artificial tear solution in one eye as they would do at home. The whole process was evaluated by two study staff. A comprehensive score system associated with eye drop instillation techniques was used to quantify the instillation technique and explore its determinants such as demographic and clinical characteristics. Results. Half of the patients (48.67% finished the administration of eye drop on first attempt.1.7 eye drops were squeezed out on average. 43 patients (37.17% got contact with ocular surface or adnexa. Only 19.7% patients had eye drop instillation techniques being defined as well. 11 patients (9.7% had prior instruction regarding using eye drops, while only 4 patients knew to occlude the tear duct by pressing the dacryocyst area. Older age and worse visual acuity were found to be independent risk factors for worse instillation technique. Conclusions. Eye drop instillation technique in glaucoma patients deserves great attention from eye care practitioners during their lifelong follow-up, especially those aged older and have worse visual acuity.

  20. Development of a three-dimensional PIV measurement technique for the experimental study of air bubble collapse phenomena

    International Nuclear Information System (INIS)

    Yang, Y.H.; Hassan, Y.A.; Schmidl, W.D.

    1995-01-01

    Particle image velocimetry (PIV) is a quantitative flow measurement technique. The objective of this study is to develop a new three-dimensional PIV technique for the experimental study of air bubble collapse phenomena. A three-dimensional measurement technique is necessary since bubble collapse is a three-dimensional phenomenon. The investigation of the velocity flow field around a collapsing air bubble can provide detailed three-dimensional quantitative information to help improve the understanding of the related heat transfer processes

  1. Experimental methods in behavioral teratology

    Energy Technology Data Exchange (ETDEWEB)

    Zbinden, G.

    1981-09-01

    Efforts are made to develop toxicological techniques with which new behavioral teratogens can be recognized. The review describes the most important experimental methods which are presently explored, and which are based on a rich body of knowledge accumulated by experimental psychologists. Most of the tests were developed with small animals, mostly with rats. They range from the rather straightforward determination of various reflexes to complex behavioral situations involving mechanical devices, operant conditioning techniques and procedures evaluating social behavior. In applying these methods in routine toxicology, it is important to remember, that many behavioral effects determined in newborn and adult animals are subtle. Moreover, they are influenced by a large variety of environmental factors affecting the health and the behavior of the mothers and of the offspring in the early and later phases of development. Therefore, the experiments must be conducted under highly standardized conditions and must be controlled rigorously. It is concluded that the best experimental strategy for the evaluation of potential behavioral teratogens is not yet established. Therefore, it would be premature to decide on a fixed protocol to be included in routine animal safety experiments for drugs and other chemical substances.

  2. Electromagnetically induced acoustic emission—novel NDT technique for damage evaluation

    Science.gov (United States)

    Finkel, P.; Godinez, V.; Miller, R.; Finlayson, R.

    2001-04-01

    A recently developed electromagnetically induced acoustic emission technique (EM AE) which can be used for damage assessment of thin walled conducting structures is described. This technique allows a structure to be loaded locally by applying an electromagnetic field in order to produce an AE response, which may be captured by conventional or fiber optic (FO) AE sensors. The advantage of this technique is that the localized dynamic stresses induced by a short current pulse in the presence of an external magnetic field aid in the detection of cracks. Also, it is shown that electromagnetic stimulation can be applied to enhance conventional ultrasonics by modulation of the scattered signal from the defect (EM UT). Experimental data is presented for the case of a fatigue crack near rivet holes in thin walled aluminum structures.

  3. Nondestructive Evaluation of Thick Concrete Using Advanced Signal Processing Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Barker, Alan M [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Santos-Villalobos, Hector J [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Albright, Austin P [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Lev [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years [1]. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.

  4. Experimental evaluation of control strategies for hydraulic servo robot

    DEFF Research Database (Denmark)

    Bech, Michael Møller; Andersen, Torben Ole; Pedersen, Henrik C.

    2013-01-01

    In this paper different linear and non-linear controllers applied to a hydraulically driven servo robot are evaluated and validated. The task is to make the actuators of the manipulator track a position reference with minimum error. Hydraulic systems are intrinsically non-linear and using linear...... in industrial servo drives. The different controllers are compared and evaluated from simulation and experimental results....

  5. Evaluation of dilatometric techniques for studies of sintering kinetics

    International Nuclear Information System (INIS)

    El-Sayed Ali, M.; Toft Soerensen, O.

    1985-04-01

    The kinetics of the initial sintering stage of CeO 2 is evaluated by three different techniques: constant heating rate dilatometry, constant shrinkage rate dilatometry and a new technique recently introduced by the authors called Stepwise Isothermal Dilatometry (SID). Comparative measurements with these techniques showed that too high activation energies were obtained with the two first techniques, both of which can be termed as nonisothermal, whereas activation energies comparable to those reported for cation diffusion in other fluorite oxides were obtained with the latter technique. Of the three techniques SID is thus considered to be the most accurate for studies of the sintering kinetics. In contrast to the two nonisothermal techniques SID has the further advantage that both the controlling mechanism and its activation energy can be determined in a single experiment. From the SID-measurement it was concluded that the initial sintering stage of CeO 2 is controlled by grain-boundary diffusion. (author)

  6. Construction of an experimental simplified model for determining of flow parameters in chemical reactors, using nuclear techniques

    International Nuclear Information System (INIS)

    Araujo Paiva, J.A. de.

    1981-03-01

    The development of a simplified experimental model for investigation of nuclear techniques to determine the solid phase parameters in gas-solid flows is presented. A method for the measurement of the solid phase residence time inside a chemical reactor of the type utilised in the cracking process of catalytic fluids is described. An appropriate radioactive labelling technique of the solid phase and the construction of an eletronic timing circuit were the principal stages in the definition of measurement technique. (Author) [pt

  7. Experimental Evaluation of Cold-Sprayed Copper Rotating Bands for Large-Caliber Projectiles

    Science.gov (United States)

    2015-05-01

    process parameters used during the initial deposition of copper material, given the observation that these initial copper rotating bands tended to “ flake ...ARL-TR-7299 ● MAY 2015 US Army Research Laboratory Experimental Evaluation of Cold-Sprayed Copper Rotating Bands for Large...Experimental Evaluation of Cold-Sprayed Copper Rotating Bands for Large-Caliber Projectiles by Michael A Minnicino Weapons and Materials Research

  8. Utility of Vascular Enhancement Technique (ClarifyTM) in Ultrasonographic Evaluation of Abdominal Vessels

    International Nuclear Information System (INIS)

    Oh, Jong Young; Cho, Jin Han; Choi, Jong Cheol; Shin, Tae Beom; Lee, Jin Hwa; Yoon, Seong Kuk; Nam, Kyung Jin

    2006-01-01

    Vascular enhancement (VE) technology(ClarifyTM) is a new technique in vascular, B-mode imaging. The purpose of this study was to evaluate the value of VE technology in ultrasonographic diagnosis of abdominal vasculature. Seventy-one adult patients (39 men and 32 women: age range, 25-89 years: mean age, 56 years) who had undergone abdominal ultrasonography were included in this study. The imaging was performed with a 1.8-4.0 MHz convex array transducer (SONOLINE, Antares, Siemens Medical Solutions, WA) by an abdominal radiologist. The radiologist obtained images of the same vascular area with each of conventional ultrasonography imaging (CUS), tissue harmonic imaging (THI), CUS plus VE technique and THI plus VE technique. Images were divided into normal (56) and abnormal (15) groups. The vessel visibility, conspicuity of the vascular wall and contrast resolution with adjacent structures were evaluated in the normal group, and the lesion conspicuity and border sharpness were evaluated in the abnormal group. On the PACS monitor, the images were graded into four grades by two radiologists in consensus. Statistical analysis was performed using Wilcoxon signed rank test. In the normal group, all parameters of the ultrasonographic imaging which applied the VE technique were superior to those of the imaging without VE technique (p < 0.05). In the abnormal group, combined use of VE technique with CUS or THI provided better results than CUS or THI alone in terms of lesion conspicuity and border sharpness (p < 0.05). THI combined with VE technique provided the best image quality among the 4 ultrasonographic methods examined in this study for the evaluation of both normal and abnormal abdominal vessels (p < 0.05). VE technology was a helpful technique to evaluate the abdominal vasculature. Furthermore, VE technique combined with THI provided better image quality than other ultrasonographic methods in the evaluation of abdominal vessels

  9. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Cavinato, Christianne C.; Campos, Leticia L., E-mail: ccavinato@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B., E-mail: bhsouza@unifesp.b, E-mail: daros.kellen@unifesp.b, E-mail: rbitel-li.ddi@epm.b [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagem; Giordani, Adelmo J. [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Servico de Radioterapia

    2011-07-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  10. FXG dosimeter response for three-dimensional conformal radiotherapy using different evaluation techniques

    International Nuclear Information System (INIS)

    Cavinato, Christianne C.; Campos, Leticia L.; Souza, Benedito H.; Carrete Junior, Henrique; Daros, Kellen A.C.; Medeiros, Regina B.; Giordani, Adelmo J.

    2011-01-01

    This work aims to compare the dose-response of the Fricke xylenol gel (FXG) dosimeter developed at IPEN using 270 Bloom gelatin from porcine skin made in Brazil evaluated using the magnetic resonance imaging (MRI) technique with the dosimetric response evaluated using the optical absorption (OA) spectrophotometry technique, in order to verify the possibility of quality assurance (QA) and reproducibility of FXG dosimeter to be carried out routinely using the OA technique for three-dimensional conformal radiotherapy (3DCRT) application using a 6 MV photons linear accelerator. The response in function of the absorbed dose of FXG dosimeter developed at IPEN presents linear behavior in clinical interest dose range when irradiated with Co-60 gamma radiation and 6 MV photons and evaluated using the MRI and OA techniques. The results indicate that the optical technique can be used for QA of FXG dosemeter when used in the possible application in QA of 3DCRT. (author)

  11. An Analytical Hierarchy Process Model for the Evaluation of College Experimental Teaching Quality

    Science.gov (United States)

    Yin, Qingli

    2013-01-01

    Taking into account the characteristics of college experimental teaching, through investigaton and analysis, evaluation indices and an Analytical Hierarchy Process (AHP) model of experimental teaching quality have been established following the analytical hierarchy process method, and the evaluation indices have been given reasonable weights. An…

  12. Experimental Evaluation of the Training Structure of the Picture Exchange Communication System (PECS)

    Science.gov (United States)

    Cummings, Anne R.; Carr, James E.; LeBlanc, Linda A.

    2012-01-01

    The Picture Exchange Communication System (PECS) is a picture-based alternative communication method that is widely accepted and utilized with individuals with disabilities. Although prior studies have examined the clinical efficacy of PECS, none have experimentally evaluated its manualized training structure. We experimentally evaluated the…

  13. Evaluation of an Experimental Adhesive Resin for Orthodontic Bonding

    Science.gov (United States)

    Durgesh, B. H.; Alkheraif, A. A.; Pavithra, D.; Hashem, M. I.; Alkhudhairy, F.; Elsharawy, M.; Divakar, D. D.; Vallittu, P. K.; Matinlinna, J. P.

    2017-07-01

    The aim of this study was to evaluate in vitro the effect of an experimental adhesive resin for orthodontic bonding by measuring some the chemical and mechanical properties. The resin demonstrated increased values of nanohardness and elastic modulus, but the differences were not significant compared with those for the Transbond XT adhesives. The experimental adhesive resin could be a feasible choice or a substitute for the traditional bis-GMA-based resins used in bonding orthodontic attachments.

  14. Evaluation of cavity size, kind, and filling technique of composite shrinkage by finite element.

    Science.gov (United States)

    Jafari, Toloo; Alaghehmad, Homayoon; Moodi, Ehsan

    2018-01-01

    Cavity preparation reduces the rigidity of tooth and its resistance to deformation. The purpose of this study was to evaluate the dimensional changes of the repaired teeth using two types of light cure composite and two methods of incremental and bulk filling by the use of finite element method. In this computerized in vitro experimental study, an intact maxillary premolar was scanned using cone beam computed tomography instrument (SCANORA, Switzerland), then each section of tooth image was transmitted to Ansys software using AUTOCAD. Then, eight sizes of cavity preparations and two methods of restoration (bulk and incremental) using two different types of composite resin materials (Heliomolar, Brilliant) were proposed on software and analysis was completed with Ansys software. Dimensional change increased by widening and deepening of the cavities. It was also increased using Brilliant composite resin and incremental filling technique. Increase in depth and type of filling technique has the greatest role of dimensional change after curing, but the type of composite resin does not have a significant role.

  15. Experimental investigation on 3D-SEM reconstructions of a wire gauge using stereo-pair technique

    DEFF Research Database (Denmark)

    Carli, Lorenzo; Genta, G.; Cantatore, Angela

    2011-01-01

    In this work an experimental investigation is addressed concerning 3D-SEM reconstructions obtained from the so-called stereo-pair technique. Three-dimensional topography of an object can be derived from two SEM images acquired from two different angles, through item rotation by means of the SEM...

  16. Evaluation of natural attenuation, bioventing, bioaugmentation and bioaugmentation-bioventing techniques, for the biodegradation of diesel in a sandy soil, through column experiments

    International Nuclear Information System (INIS)

    Muskus Morales, Angelica Maria; Santoyo Munoz, Claudia; Plata Quintero, Luijesmarth Silvia

    2013-01-01

    The present study was developed within an inter-institutional agreement between the Universidad Pontificia Bolivariana, UPB-BBGA and the Colombian Petroleum Institute-ICP, in order to provide a solution to an environmental problem that occurs in areas where hydrocarbons are handled and where sandy soils have been found to be contaminated with diesel fuel with concentrations up to 6% at a maximum depth of 80 cm. For this study, the soil samples were artificially contaminated with diesel fuel in order to evaluate Natural Attenuation, Bioventing, Bioaugmentation and Bioaugmentation-Bioventing soil remediation techniques through the use of column experiments. The design parameters, column dimensions, inflow, diesel concentration, dissolved oxygen, bacterial growth, and monitoring was defined. Bioaugmentation was performed inoculating a bacterial consortium produced by the ICP. The experimental setup was assembled in triplicate and was monitored through a period of four months. The experimental results showed that Bioventing technique was the most effective, reaching up to 97% diesel removal from the contaminated soil; with the Bioaugmentation - Bioventing, diesel fuel removal percentage was 75%, and the Natural Attenuation and Bioaugmentation techniques resulted in diesel fuel removal percentages not greater than 48%. This study showed that the microbial consortium evaluated and provided by the Colombian Petroleum Institute proved to be not efficient for potentializing bioremediation processes of sandy soils contaminated with diesel fuel.

  17. Evaluation of Damping Using Time Domain OMA Techniques

    DEFF Research Database (Denmark)

    Bajric, Anela; Brincker, Rune; Georgakis, Christos T.

    2014-01-01

    . In this paper a comparison is made of the effectiveness of three existing OMA techniques in providing accurate damping estimates for varying loadings, levels of noise, number of added measurement channels and structural damping. The evaluated techniques are derived in the time domain and are namely the Ibrahim...... Time Domain (ITD), Eigenvalue Realization Algorithm (ERA) and the Polyreference Time Domain (PTD). The response of a two degree-of-freedom (2DOF) system is numerically established from specified modal parameters with well separated and closely spaced modes. Two types of response are considered, free...

  18. Experimental Evaluations of Selected Immersion Hypothermia Protection Equipment.

    Science.gov (United States)

    1979-10-12

    the research were Jim Strawhorn, Tom Horseman and Jay Smith. ii Srb "Peeat~loj 0",___e_____._______ . TABLE OF CONTENTS EXPERIMENTAL EVALUATIONS OF...In death . Insulating the body will decrease the amount of heat removed. The thickness of an Insulation layer and the type of material from which it is

  19. Non-destructive technique to verify clearance of pipes

    Directory of Open Access Journals (Sweden)

    Savidou Anastasia

    2010-01-01

    Full Text Available A semi-empirical, non-destructive technique to evaluate the activity of gamma ray emitters in contaminated pipes is discussed. The technique is based on in-situ measurements by a portable NaI gamma ray spectrometer. The efficiency of the detector for the pipe and detector configuration was evaluated by Monte Carlo calculations performed using the MCNP code. Gamma ray detector full-energy peak efficiency was predicted assuming a homogeneous activity distribution over the internal surface of the pipe for 344 keV, 614 keV, 662 keV, and 1332 keV photons, representing Eu-152, Ag-118m, Cs-137, and Co-60 contamination, respectively. The effect of inhomogeneity on the accuracy of the technique was also examined. The model was validated against experimental measurements performed using a Cs-137 volume calibration source representing a contaminated pipe and good agreement was found between the calculated and experimental results. The technique represents a sensitive and cost-effective technology for calibrating portable gamma ray spectrometry systems and can be applied in a range of radiation protection and waste management applications.

  20. Evaluation of fish handling techniques employed by artisanal fishers ...

    African Journals Online (AJOL)

    Evaluation of fish handling techniques employed by artisanal fishers on quality of Lethrinids and Siganids fish genera at landing time along the Kenyan coast using sensory and microbiological methods.

  1. The Nonuse, Misuse, and Proper Use of Pilot Studies in Experimental Evaluation Research

    Science.gov (United States)

    Westlund, Erik; Stuart, Elizabeth A.

    2017-01-01

    This article discusses the nonuse, misuse, and proper use of pilot studies in experimental evaluation research. The authors first show that there is little theoretical, practical, or empirical guidance available to researchers who seek to incorporate pilot studies into experimental evaluation research designs. The authors then discuss how pilot…

  2. Estimation of covariance matrix on the experimental data for nuclear data evaluation

    International Nuclear Information System (INIS)

    Murata, T.

    1985-01-01

    In order to evaluate fission and capture cross sections of some U and Pu isotopes for JENDL-3, we have a plan for evaluating them simultaneously with a least-squares method. For the simultaneous evaluation, the covariance matrix is required for each experimental data set. In the present work, we have studied the procedures for deriving the covariance matrix from the error data given in the experimental papers. The covariance matrices were obtained using the partial errors and estimated correlation coefficients between the same type partial errors for different neutron energy. Some examples of the covariance matrix estimation are explained and the preliminary results of the simultaneous evaluation are presented. (author)

  3. Application of Fuzzy TOPSIS for evaluating machining techniques using sustainability metrics

    Science.gov (United States)

    Digalwar, Abhijeet K.

    2018-04-01

    Sustainable processes and techniques are getting increased attention over the last few decades due to rising concerns over the environment, improved focus on productivity and stringency in environmental as well as occupational health and safety norms. The present work analyzes the research on sustainable machining techniques and identifies techniques and parameters on which sustainability of a process is evaluated. Based on the analysis these parameters are then adopted as criteria’s to evaluate different sustainable machining techniques such as Cryogenic Machining, Dry Machining, Minimum Quantity Lubrication (MQL) and High Pressure Jet Assisted Machining (HPJAM) using a fuzzy TOPSIS framework. In order to facilitate easy arithmetic, the linguistic variables represented by fuzzy numbers are transformed into crisp numbers based on graded mean representation. Cryogenic machining was found to be the best alternative sustainable technique as per the fuzzy TOPSIS framework adopted. The paper provides a method to deal with multi criteria decision making problems in a complex and linguistic environment.

  4. Construction accident narrative classification: An evaluation of text mining techniques.

    Science.gov (United States)

    Goh, Yang Miang; Ubeynarayana, C U

    2017-11-01

    Learning from past accidents is fundamental to accident prevention. Thus, accident and near miss reporting are encouraged by organizations and regulators. However, for organizations managing large safety databases, the time taken to accurately classify accident and near miss narratives will be very significant. This study aims to evaluate the utility of various text mining classification techniques in classifying 1000 publicly available construction accident narratives obtained from the US OSHA website. The study evaluated six machine learning algorithms, including support vector machine (SVM), linear regression (LR), random forest (RF), k-nearest neighbor (KNN), decision tree (DT) and Naive Bayes (NB), and found that SVM produced the best performance in classifying the test set of 251 cases. Further experimentation with tokenization of the processed text and non-linear SVM were also conducted. In addition, a grid search was conducted on the hyperparameters of the SVM models. It was found that the best performing classifiers were linear SVM with unigram tokenization and radial basis function (RBF) SVM with uni-gram tokenization. In view of its relative simplicity, the linear SVM is recommended. Across the 11 labels of accident causes or types, the precision of the linear SVM ranged from 0.5 to 1, recall ranged from 0.36 to 0.9 and F1 score was between 0.45 and 0.92. The reasons for misclassification were discussed and suggestions on ways to improve the performance were provided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Experimental evaluation of cell liners

    International Nuclear Information System (INIS)

    Wierman, R.W.; Simmons, L.D.; Muhlestein, L.D.

    Cell liners may be used in breeder reactor sodium pipe ways, sodium cells, and lower cavity region to provide a leak-tight cell and to protect the concrete from sodium in the unlikely event of a sodium spill. The objectives of the HEDL liner verification test program are to evaluate the integrity of liner concepts under postulated accident conditions and to develop the experimental data base which will demonstrate that liners will not fail. Two specific tests are reported; a high temperature liner feature test, and a large-scale liner sodium spill test. In both tests no failures of the liners or tendencies toward failure were detected. The discussed liner designs appeared to be conservative, and the liner strength appeared to be more than adequate

  6. Experimental techniques for the detection of the high energy gamma rays of cosmic origin

    International Nuclear Information System (INIS)

    Dumitrescu, Gh.; Angelescu, T.; Radu, A.A.

    2002-01-01

    The observation of high energy gamma rays of cosmic origin in the early 90 by Volcano Ranch experiment opened a new direction of study in astrophysics. The very high energy and the very low flux of these gamma rays, posed numerous detection problems which in turn were the object of a very intense research activity. The present article tries to review the detection techniques for the high energy gamma rays of cosmic origin. In the 'Introduction' we summarize the specific problems involved in the detection of this type of radiation. 'Chapter 1' presents the classic technique based on the use of scintillation detectors. 'Chapter 2' includes the imaging atmospheric Cherenkov technique (IACT) and the sampling wavefront technique. 'Chapter 3' is dedicated to the detection of the atmospheric nitrogen. 'Chapter 4' describes issues related to the calibration of the detectors, the cross checking of the experimental data, the use of the Monte Carlo simulations and the use of the density observed at a distance of 600 m S(600), in order to estimate the primary energy. The characteristics of some future developments of the above presented techniques are included in the last chapter. (authors)

  7. Thoracoabdominal mobility evaluation by photogrammetry in newborns after expiratory flow increase technique

    Directory of Open Access Journals (Sweden)

    Júlia Isabel de Araújo Guerra

    Full Text Available Abstract Introduction: Expiratory flow increase is a maneuver of respiratory physical therapy that promotes flow direction to the upper airways however, when applied in newborns, it may result in changes of thoracoabdominal mobility. Objective: To evaluate the thoracoabdominal mobility by photogrammetry in newborns after expiratory flow increase technique. Methods: Experimental blind study performed with newborns in supine position on a support table with upper limbs flexed, abducted and externally rotated and hip flexed at 110°. Adhesive markers were allocated for geometric delimitation of the thoracoabdominal compartment and expiratory flow increase technique was performed for 5 minutes with the therapist’s hands on the thorax and abdomen. Newborns were filmed before and after the maneuver and the frames were analyzed in AutoCAD® software by a blinded investigator at the time of the procedure. The largest and the smallest thoracoabdominal area were expressed in cm2 and the mean values were compared between two moments (pre and post maneuver by paired t test. Results: Twenty newborns with a mean age of 39 weeks were included. Before the maneuver, thoracoabdominal area was 56.1 cm2 during expiration and 59.7 cm2 during inspiration, and after the maneuver the value was 56.2 cm2 during expiration and 59.8 cm2 during inspiration, with no statistical difference between before and after (p = 0.97, p = 0.92, respectively. Conclusion: Results demonstrate that expiratory flow increase technique does not seem to change thoracoabdominal mobility of healthy newborns.

  8. Evaluation of the Use of Two Teaching Techniques in Engineering

    Directory of Open Access Journals (Sweden)

    Jose Antonio Alvarez Salas

    2014-06-01

    Full Text Available This paper presents an analysis of the practical implementation of two teaching techniques so-called Problem-Based Learning and Cooperative Learning. These techniques were applied to some courses in the Department of Mechanical and Electrical Engineering and evaluated through assessment rubrics. In a sample of students and teachers, the assessment rubrics were applied to numerically evaluate the proportion of each course, in which the teacher uses traditional teaching versus teaching for meaningful learning. The results of the presented analysis allow to verify the use of these teaching techniques by professors of the Department of Mechanical and Electrical Engineering. This activity was developed as a part of the work established by the Institutional Development Plan of the Faculty of Engineering, which includes the strategic objective of developing an innovative educational model in the following ten years.

  9. Evaluation of Urban Planning Projects Criteria Using Fuzzy AHP Technique

    Directory of Open Access Journals (Sweden)

    Walid Mustafa Kamas

    2017-05-01

    Full Text Available In this research, Fuzzy Analytic Hierarchy Process technique is applied (Fuzzy AHP which is one of multi-criteria decision making techniques to evaluate the criteria for urban planning projects, the project of developing master plan of Al-Muqdadiyah city to 2035 has been chosen as a case study. The researcher prepared a list of criteria in addition to the authorized departments criteria and previous researches in order to choose optimized master plan according to these criteria. This research aims at employing the foundations of (Fuzzy AHP technique in evaluating urban planning criteria precisely and flexible. The results of the data analysis to the individuals of the sample who are specialists, in this aspect. The land use criteria are more important than the rest of the criteria in these projects, where it received the relative importance with percentile (42.1 %.

  10. Evaluation of alternative drying techniques for the earthworm flour processing

    Directory of Open Access Journals (Sweden)

    Laura Suárez Hernández

    2016-01-01

    Full Text Available Production of earthworm flour includes several steps, among which the most critical is the drying process due to factors such as time and energ y requirements. In addition, the information available about this process is relquite limited. Thus, this work evaluated four drying techniques likely to be implemented by lombricultores: sun drying, oven drying, drying tunnel and microwave assisted drying. Drying kinetics values were obtained for all drying techniques, and specific parameters as the following were evaluated: drying tray material (stainless and ceramic steel for sun drying, microwave power (30 %, 50 % and 80 % and amount of material to be dried (72 and 100 g for microwave assisted drying, temperature (50, 65, 90 and 100 °C for oven drying, and temperature (50 and 63 °C and air speed (2.9 to 3.6 m/s for tunnel drying. It was determined that the most efficient technique is the drying tunnel, because this allows the combination of heat transfer by conduction and convection, and enables controlling the operating parameters. Finally, nutritional analyzes were performed in samples obtained by each drying technique evaluated. The crude protein content for sun drying, microwave assisted drying, oven drying and tunnel drying were 66.36 %, 67.91 %, 60.35 % and 62.33 % respectively, indicating that the drying method and operating parameters do not significantly affect the crude protein content.

  11. A comparative evaluation of five human reliability assessment techniques

    International Nuclear Information System (INIS)

    Kirwan, B.

    1988-01-01

    A field experiment was undertaken to evaluate the accuracy, usefulness, and resources requirements of five human reliability quantification techniques (Techniques for Human Error Rate Prediction (THERP); Paired Comparisons, Human Error Assessment and Reduction Technique (HEART), Success Liklihood Index Method (SLIM)-Multi Attribute Utility Decomposition (MAUD), and Absolute Probability Judgement). This was achieved by assessing technique predictions against a set of known human error probabilities, and by comparing their predictions on a set of five realistic Probabilisitc Risk Assessment (PRA) human error. On a combined measure of accuracy THERP and Absolute Probability Judgement performed best, whilst HEART showed indications of accuracy and was lower in resources usage than other techniques. HEART and THERP both appear to benefit from using trained assessors in order to obtain the best results. SLIM and Paired Comparisons require further research on achieving a robust calibration relationship between their scale values and absolute probabilities. (author)

  12. Comparison of experimental techniques for measuring fracture toughness of austenitic stainless steels by performance of a comparative round-robin test

    International Nuclear Information System (INIS)

    Huthmann, H.; Akhurst, K.N.; Bethmont, M.; Picker, C.; Rongen, H.J.M. van; Soulat, P.

    1987-01-01

    The CEC fast breeder coordinating committee, activities group 3 Materials of the working group for codes and standards, has recently examined existing data on the fracture toughness of austenitic stainless steels. As a result, the committee decided to sponsor a round robin test programme aimed at comparing experimental techniques and assisting in establishing a standard test method for these steels. The contract for this programme was placed with Interatom, who have subcontracted with CEA-Saclay, CEGB-Leatherhead, TNO-Apeldoorn and UKAEA-Risley. Additionally CISE/ENEL-Milano and EdF-Les Renardieres took part in the round robin. This final report presents a common evaluation and discussion of the results gained by the different laboratories

  13. MATLAB platform for Monte Carlo planning and dosimetry experimental evaluation

    International Nuclear Information System (INIS)

    Baeza, J. A.; Ureba, A.; Jimenez-Ortega, E.; Pereira-Barbeiro, A. R.; Leal, A.

    2013-01-01

    A new platform for the full Monte Carlo planning and an independent experimental evaluation that it can be integrated into clinical practice. The tool has proved its usefulness and efficiency and now forms part of the flow of work of our research group, the tool used for the generation of results, which are to be suitably revised and are being published. This software is an effort of integration of numerous algorithms of image processing, along with planning optimization algorithms, allowing the process of MCTP planning from a single interface. In addition, becomes a flexible and accurate tool for the evaluation of experimental dosimetric data for the quality control of actual treatments. (Author)

  14. Experimental Evaluation of Electric Power Grid Visualization Tools in the EIOC

    Energy Technology Data Exchange (ETDEWEB)

    Greitzer, Frank L.; Dauenhauer, Peter M.; Wierks, Tamara G.; Podmore, Robin; Dalton, Angela C.

    2009-12-01

    The present study follows an initial human factors evaluation of four electric power grid visualization tools and reports on an empirical evaluation of two of the four tools: Graphical Contingency Analysis, and Phasor State Estimator. The evaluation was conducted within specific experimental studies designed to measure the impact on decision making performance.

  15. Evaluation of phased array UT conditions using ultrasonic visualization technique

    International Nuclear Information System (INIS)

    Furukawa, Takashi; Komura, Ichirou

    2008-01-01

    Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)

  16. Criteria and evaluation of three decontamination techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tripp, J.L.

    1994-01-01

    Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP), which is part of the Idaho National Engineering Laboratory (INEL), have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using the current decontamination techniques of chemical/water flushes and steam jet cleaning. This waste requires a large amount of cold chemical additive to process because the low melting temperatures of sodium and potassium salts cause agglomeration in the bed of the calciner vessel. Criteria have been established for evaluating methods and technologies available for decontaminating equipment and facilities. The criteria were weighted according to their relative importance using a Kepner-Tregoe Problem Solving process. These criteria were used to rank three decontamination techniques new to the ICPP: laser ablation, liquid abrasive blasting and CO{sub 2} pellet blasting, against the standard decontamination techniques of sodium-based chemical cleaning and water/steam jets used.

  17. Criteria and evaluation of three decontamination techniques

    International Nuclear Information System (INIS)

    Tripp, J.L.

    1994-01-01

    Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP), which is part of the Idaho National Engineering Laboratory (INEL), have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using the current decontamination techniques of chemical/water flushes and steam jet cleaning. This waste requires a large amount of cold chemical additive to process because the low melting temperatures of sodium and potassium salts cause agglomeration in the bed of the calciner vessel. Criteria have been established for evaluating methods and technologies available for decontaminating equipment and facilities. The criteria were weighted according to their relative importance using a Kepner-Tregoe Problem Solving process. These criteria were used to rank three decontamination techniques new to the ICPP: laser ablation, liquid abrasive blasting and CO 2 pellet blasting, against the standard decontamination techniques of sodium-based chemical cleaning and water/steam jets used

  18. Head and neck computed tomography virtual endoscopy: evaluation of a new imaging technique.

    Science.gov (United States)

    Gallivan, R P; Nguyen, T H; Armstrong, W B

    1999-10-01

    To evaluate a new radiographic imaging technique: computed tomography virtual endoscopy (CTVE) for head and neck tumors. Twenty-one patients presenting with head and neck masses who underwent axial computed tomography (CT) scan with contrast were evaluated by CTVE. Comparisons were made with video-recorded images and operative records to evaluate the potential utility of this new imaging technique. Twenty-one patients with aerodigestive head and neck tumors were evaluated by CTVE. One patient had a nasal cylindrical cell papilloma; the remainder, squamous cell carcinomas distributed throughout the upper aerodigestive tract. Patients underwent complete head and neck examination, flexible laryngoscopy, axial CT with contrast, CTVE, and in most cases, operative endoscopy. Available clinical and radiographic evaluations were compared and correlated to CTVE findings. CTVE accurately demonstrated abnormalities caused by intraluminal tumor, but where there was apposition of normal tissue against tumor, inaccurate depictions of surface contour occurred. Contour resolution was limited, and mucosal irregularity could not be defined. There was very good overall correlation between virtual images, flexible laryngoscopic findings, rigid endoscopy, and operative evaluation in cases where oncological resections were performed. CTVE appears to be most accurate in evaluation of subglottic and nasopharyngeal anatomy in our series of patients. CTVE is a new radiographic technique that provides surface-contour details. The technique is undergoing rapid technical evolution, and although the image quality is limited in situations where there is apposition of tissue folds, there are a number of potential applications for this new imaging technique.

  19. Evaluation of analytical techniques to determine matals in Sodium

    International Nuclear Information System (INIS)

    Biancifiori, M.A.; Zappa, G.; Amico, A.

    1985-01-01

    The influence of some instrumental parameters on the analysis of CA, Co, Cr, Cu, Fe, K, Mg, Mn, and Ni in Sodium solutions, by means of Flame Atomic Absorption Spectroscopy (FAAS), is evaluated. The best operating parameters are established and the possibility of application of this analytical technique to the detection of the metallic impurities in Sodium is evaluated, considering the concentration values of nuclear interest

  20. Reported credibility techniques in higher education evaluation studies that use qualitative methods: A research synthesis.

    Science.gov (United States)

    Liao, Hongjing; Hitchcock, John

    2018-06-01

    This synthesis study examined the reported use of credibility techniques in higher education evaluation articles that use qualitative methods. The sample included 118 articles published in six leading higher education evaluation journals from 2003 to 2012. Mixed methods approaches were used to identify key credibility techniques reported across the articles, document the frequency of these techniques, and describe their use and properties. Two broad sets of techniques were of interest: primary design techniques (i.e., basic), such as sampling/participant recruitment strategies, data collection methods, analytic details, and additional qualitative credibility techniques (e.g., member checking, negative case analyses, peer debriefing). The majority of evaluation articles reported use of primary techniques although there was wide variation in the amount of supporting detail; most of the articles did not describe the use of additional credibility techniques. This suggests that editors of evaluation journals should encourage the reporting of qualitative design details and authors should develop strategies yielding fuller methodological description. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Experimental study of laser ablation as sample introduction technique for inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Van Winckel, S.

    2001-01-01

    The contribution consists of an abstract of a PhD thesis. In the PhD study, several complementary applications of laser-ablation were investigated in order to characterise experimentally laser ablation (LA) as a sample introduction technique for ICP-MS. Three applications of LA as a sample introduction technique are discussed: (1) the microchemical analysis of the patina of weathered marble; (2) the possibility to measure isotope ratios (in particular Pb isotope ratios in archaeological bronze artefacts); and (3) the determination of Si in Al as part of a dosimetric study of the BR2 reactor vessel

  2. A novel microbond bundle pullout technique to evaluate the ...

    Indian Academy of Sciences (India)

    ... pullout technique to evaluate the interfacial properties of fibre-reinforced plastic composites ... https://www.ias.ac.in/article/fulltext/boms/040/04/0737-0744. Keywords. Microbond bundle pullout test; carbon/epoxy; fibre-reinforced composites; ...

  3. Comparison of porosity measurement techniques for porous titanium scaffolds evaluation

    International Nuclear Information System (INIS)

    Oliveira, M.V.; Ribeiro, A.A.; Moreira, A.C.; Moraes, A.M.C.; Appoloni, C.R.; Pereira, L.C.

    2009-01-01

    Porous titanium has been used for grafts and implant coatings as it allows the mechanical interlocking of the pores and bone. Evaluation of porous scaffolds for bone regeneration is essential for their manufacture. Porosity, pore size, pore shape and pore homogeneity are parameters that influence strongly the mechanical strength and biological functionality. In this study, porous titanium samples were manufactured by powder metallurgy by using pure titanium powders mixed with a pore former. The quantification of the porosity parameters was assessed in this work by geometric method and gamma-ray transmission, the non-destructive techniques and metallographic images processing, a destructive technique. Qualitative evaluation of pore morphology and surface topography were performed by scanning electron microscopy and optical microscopy. The results obtained and the effectiveness of the techniques used were compared in order to select those most suitable for characterization of porous titanium scaffolds. (author)

  4. Evaluation of examination techniques for ferritic stainless steel feedwater heater tubing

    International Nuclear Information System (INIS)

    Nugent, M.J.; Catapano, M.C.

    1995-01-01

    Ferritic stainless steel has been finding increased application in utility plant feedwater heaters due to good strength and corrosion resistance and absence of potential copper contamination of feedwater system. Ferritic stainless steel is highly magnetic and is generally not inspectable using conventional eddy current testing techniques. A variety of techniques have been developed for inspection of this tubing material used in typical heat exchanger applications. Through a project funded by the Empire State Electric Energy Research Corporation (ESEERCO), the evaluation of data generated by four present state of the art NDE testing techniques were evaluated on a controlled mock-up of the heater tubing with service related defects. The primary objective was to determine the strengths and limitations of each method. The testing of two in service feedwater heaters at the Consolidated Edison Company of New York, Inc. (Con Edison's) Arthur Kill Generating Station also allowed further evaluations based on actual field conditions

  5. The measuring technique developed to evaluate the thermal diffusivity of the multi-layered thin film specimens

    Directory of Open Access Journals (Sweden)

    Li Tse-Chang

    2017-01-01

    Full Text Available In the present study, the thermal diffusivities of the Al, Si and ITO films deposited on the SUS304 steel substrate are evaluated via the present technique. Before applying this technique, the temperature for the thin film of the multi-layered specimen is developed theoretically for the one- dimensional steady heat conduction in response to amplitude and frequency of the periodically oscillating temperature imposed by a peltier placed beneath the specimen's substrate. By the thermal-electrical data processing system excluding the lock-in amplifier, the temperature frequency a3 has been proved first to be independent of the electrical voltage applied to the peltier and the contact position of the thermocouples. The experimental data of phase difference for three kinds of specimen are regressed well by a straight line with a slope. Then, the thermal diffusivity of the thin film is thus determined if the slope value and the film- thickness are available. In the present arrangements for the thermocouples, two thermal diffusivity values are quite close each other and valid for every kind of specimen. This technique can provide an efficient, low-cost method for the thermal diffusivity measurements of thin films.

  6. Experimental and Analytical Evaluation of a Composite Honeycomb Deployable Energy Absorber

    Science.gov (United States)

    Jackson, Karen E.; Kellas, Sotiris; Horta, Lucas G.; Annett, Martin S.; Polanco, Michael A.; Littell, Justin D.; Fasanella, Edwin L.

    2011-01-01

    In 2006, the NASA Subsonic Rotary Wing Aeronautics Program sponsored the experimental and analytical evaluation of an externally deployable composite honeycomb structure that is designed to attenuate impact energy during helicopter crashes. The concept, which is designated the Deployable Energy Absorber (DEA), utilizes an expandable Kevlar honeycomb structure to dissipate kinetic energy through crushing. The DEA incorporates a unique flexible hinge design that allows the honeycomb to be packaged and stowed flat until needed for deployment. A variety of deployment options such as linear, radial, and/or hybrid methods can be used. Experimental evaluation of the DEA utilized a building block approach that included material characterization testing of its constituent, Kevlar -129 fabric/epoxy, and flexural testing of single hexagonal cells. In addition, the energy attenuation capabilities of the DEA were demonstrated through multi-cell component dynamic crush tests, and vertical drop tests of a composite fuselage section, retrofitted with DEA blocks, onto concrete, water, and soft soil. During each stage of the DEA evaluation process, finite element models of the test articles were developed and simulations were performed using the explicit, nonlinear transient dynamic finite element code, LS-DYNA. This report documents the results of the experimental evaluation that was conducted to assess the energy absorption capabilities of the DEA.

  7. Further development of the instrument and technique for photometric evaluation of autoradiograms

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, K; Baumbach, H; Birkholz, W; Kiese, H J [Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung

    1976-01-01

    Analogous and digital techniques for evaluation of autoradiograms are compared and measured for critical evaluation of autoradiograms. Additional instruments to a Zeiss-Photometer for digital and analogous evaluation of autoradiograms are described.

  8. Measurement of Mixing Rate between Fuel Subchannels: Development of a new Experimental Technique

    International Nuclear Information System (INIS)

    Silin, Nicolas; Barbero, Jose; Bubach, Ernesto; Juanico, Luis

    2000-01-01

    A superficial heater of nickel applied over a ceramic substrate was designed and constructed, together with a system of high sensitivity to measure temperature differentials. The use of both techniques was evaluated and it might allow for the wider use of the method of differential thermal analysis to quantify the turbulent mixing between coupled hydraulic subchannels in fuel elements. Even more, the method presents important advantages as compared to the more complicated techniques known (laser Doppler anemometry)

  9. Experimental approaches for evaluating the invasion risk of biofuel crops

    International Nuclear Information System (INIS)

    Luke Flory, S; Sollenberger, Lynn E; Lorentz, Kimberly A; Gordon, Doria R

    2012-01-01

    There is growing concern that non-native plants cultivated for bioenergy production might escape and result in harmful invasions in natural areas. Literature-derived assessment tools used to evaluate invasion risk are beneficial for screening, but cannot be used to assess novel cultivars or genotypes. Experimental approaches are needed to help quantify invasion risk but protocols for such tools are lacking. We review current methods for evaluating invasion risk and make recommendations for incremental tests from small-scale experiments to widespread, controlled introductions. First, local experiments should be performed to identify conditions that are favorable for germination, survival, and growth of candidate biofuel crops. Subsequently, experimental introductions in semi-natural areas can be used to assess factors important for establishment and performance such as disturbance, founder population size, and timing of introduction across variable habitats. Finally, to fully characterize invasion risk, experimental introductions should be conducted across the expected geographic range of cultivation over multiple years. Any field-based testing should be accompanied by safeguards and monitoring for early detection of spread. Despite the costs of conducting experimental tests of invasion risk, empirical screening will greatly improve our ability to determine if the benefits of a proposed biofuel species outweigh the projected risks of invasions. (letter)

  10. Evaluation of fuel performance with different enrichment degrees for an experimental device

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Pino, Eddy S.; Gomes, Daniel S.; Abe, Alfredo Y.; Silva, Antonio Teixeira e

    2013-01-01

    Evaluation of fuel performance is conventionally carried out using specific codes developed to this aim. The obtained data are confirmed by experimental measurements performed using devices, which are located inside research reactors, projected to simulate reactor conditions under normal operation. Due to the limitations of the available reactor core length for irradiation in research reactors core, fuel rods used to obtain experimental data must present the same characteristics of the real fuel rod, but with a shorter length. Then, in order to compare the obtained results to the expected behavior of the real fuel rod, the experimental fuel rod should be designed with a free volume to fuel volume ratio very closed to the one of the full scale fuel rod. The aim of this paper is to evaluate some parameters and aspects related to the fuel rod behavior in a rod applied to the experimental irradiation device called Nuclear Fuel Irradiation Circuit (CAFE-Mod1) considering two fuel enrichment degrees: a typical commercial PWR enrichment and a value about 4 times higher. This evaluation is carried out by means of an adapted fuel performance code. Some of the parameter evaluated were fuel temperature and fission gas release as function of the fuel enrichment level. The results obtained in this paper were very similar to the ones previously obtained without consider similar free volume between the experimental and the full length fuel rod, regardless of low increases observed for the internal rod pressure and the amount of fission gas released. (author)

  11. Experimental Issues in Testing a Semiactive Technique to Control Earthquake Induced Vibration

    Directory of Open Access Journals (Sweden)

    Nicola Caterino

    2014-01-01

    Full Text Available This work focuses on the issues to deal with when approaching experimental testing of structures equipped with semiactive control (SA systems. It starts from practical experience authors gained in a recent wide campaign on a large scale steel frame structure provided with a control system based on magnetorheological dampers. The latter are special devices able to achieve a wide range of physical behaviours using low-power electrical currents. Experimental activities involving the use of controllable devices require special attention in solving specific aspects that characterize each of the three phases of the SA control loop: acquisition, processing, and command. Most of them are uncommon to any other type of structural testing. This paper emphasizes the importance of the experimental assessment of SA systems and shows how many problematic issues likely to happen in real applications are also present when testing these systems experimentally. This paper highlights several problematic aspects and illustrates how they can be addressed in order to achieve a more realistic evaluation of the effectiveness of SA control solutions. Undesired and unavoidable effects like delays and control malfunction are also remarked. A discussion on the way to reduce their incidence is also offered.

  12. Monitoring and evaluation techniques for airborne contamination

    Energy Technology Data Exchange (ETDEWEB)

    Yihua, Xia [China Inst. of Atomic Energy, Beijing (China)

    1997-06-01

    Monitoring and evaluation of airborne contamination are of great importance for the purpose of protection of health and safety of workers in nuclear installations. Because airborne contamination is one of the key sources to cause exposure to individuals by inhalation and digestion, and to cause diffusion of contaminants in the environment. The main objectives of monitoring and evaluation of airborne contamination are: to detect promptly a loss of control of airborne material, to help identify those individuals and predict exposure levels, to assess the intake and dose commitment to the individuals, and to provide sufficient documentation of airborne radioactivity. From the viewpoint of radiation protection, the radioactive contaminants in air can be classified into the following types: airborne aerosol, gas and noble gas, and volatile gas. In this paper, the following items are described: sampling methods and techniques, measurement and evaluation, and particle size analysis. (G.K.)

  13. Monitoring and evaluation techniques for airborne contamination

    International Nuclear Information System (INIS)

    Xia Yihua

    1997-01-01

    Monitoring and evaluation of airborne contamination are of great importance for the purpose of protection of health and safety of workers in nuclear installations. Because airborne contamination is one of the key sources to cause exposure to individuals by inhalation and digestion, and to cause diffusion of contaminants in the environment. The main objectives of monitoring and evaluation of airborne contamination are: to detect promptly a loss of control of airborne material, to help identify those individuals and predict exposure levels, to assess the intake and dose commitment to the individuals, and to provide sufficient documentation of airborne radioactivity. From the viewpoint of radiation protection, the radioactive contaminants in air can be classified into the following types: airborne aerosol, gas and noble gas, and volatile gas. In this paper, the following items are described: sampling methods and techniques, measurement and evaluation, and particle size analysis. (G.K.)

  14. Means of Ensuring Information Security and Experimental Study of the Efficiency of Forensic Handwriting Techniques

    OpenAIRE

    Sergey Dmitrievich Kulik; Konstantin Igorevich Tkachenko; Denis Arturovich Nikonets

    2013-01-01

    This article deals with the special means, which allow to protect the information in the document. They are an integral part of the automated tools of ensuring the information security. It is proposed the use of a special input device PC Notes Taker. The results of experimental verification of the effectiveness of forensic handwriting techniques are described.

  15. Comparative Evaluation of Marginal Adaptation and Fracture Strength of Different Ceramic Inlays Produced by CEREC Omnicam and Heat-Pressed Technique

    OpenAIRE

    Oz, F. D.; Bolay, S.

    2018-01-01

    Objective. The aim of this in vitro study was to evaluate marginal adaptation and fracture strength of inlays produced by CEREC Omnicam using different types of blocs and heat-pressed technique. Methods: Seventy-five extracted human mandibular molars were divided randomly into 5 groups (n=15). 60 molars in four groups received MOD inlay preparations. Experimental groups were CO: Intact teeth, EC: IPS e.max CAD and CEREC, LU: Lava Ultimate and CEREC, EL: IPS Empress CAD and CEREC, EP: IPS Empr...

  16. Repeatability, Reproducibility and Standardisation of a Laser Doppler Imaging Technique for the Evaluation of Normal Mouse Hindlimb Perfusion

    Directory of Open Access Journals (Sweden)

    Arturo Brunetti

    2012-12-01

    Full Text Available Background. Preclinical perfusion studies are useful for the improvement of diagnosis and therapy in dermatologic, cardiovascular and rheumatic human diseases. The Laser Doppler Perfusion Imaging (LDPI technique has been used to evaluate superficial alterations of the skin microcirculation in surgically induced murine hindlimb ischemia. We assessed the reproducibility and the accuracy of LDPI acquisitions and identified several critical factors that could affect LDPI measurements in mice. Methods. Twenty mice were analysed. Statistical standardisation and a repeatability and reproducibility analysis were performed on mouse perfusion signals with respect to differences in body temperature, the presence or absence of hair, the type of anaesthesia used for LDPI measurements and the position of the mouse body. Results. We found excellent correlations among measurements made by the same operator (i.e., repeatability under the same experimental conditions and by two different operators (i.e., reproducibility. A Bland-Altman analysis showed the absence of bias in repeatability (p = 0.29 or reproducibility (p = 0.89. The limits of agreement for repeatability were –0.357 and –0.033, and for reproducibility, they were –0.270 and 0.238. Significant differences in perfusion values were observed in different experimental groups. Conclusions. Different experimental conditions must be considered as a starting point for the evaluation of new drugs and strategic therapies.

  17. Thromboelastometric evaluation of horses submitted to experimental thrombosis and jugular thrombectomy

    Directory of Open Access Journals (Sweden)

    Dietrich Pizzigatti

    Full Text Available Abstract: Jugular thrombosis in horses occurs commonly in iatrogenic situations, secondary to endotoxemic clinical condition and disseminated vascular coagulation, potentially leading to death. Thus, hemostatic evaluation becomes necessary and extremely important for monitoring the risks of systemic hypercoagulability and for the efficiency of allopathic and surgical treatment. This paper describes the hemostatic behavior in experimental jugular thrombosis of ten healthy equines, subsequently submitted to two thrombectomy techniques and receiving heparin sodium as anti-rethrombosis therapy. These animals were evaluated for 20 days by thromboelastometry (TEM, platelet count, hematocrit and fibrinogen, at four moments: pre-induction to phlebitis (D0-MPF; three days after thrombophlebitis induction (D3-MFM; 6 days after, - moment of thrombophlebitis - (D9-MT; and 54 (D16 and 126 (D19 hours after thrombectomies (PTM. Thrombectomy was performed via a Vollmar Ring (group 1, n=5 and Fogarty catheter (group 2, n=5. All the animals received heparin (150 UI/kg, SC every 12 hours, for ten days after the respective thrombectomies. Through the blood samples were evaluated TEM, activated partial thromboplastin time (aPTT and prothrombin time (PT, dosing of fibrinogen, hematocrit and platelet count at the abovementioned moments. For comparison between groups and moments the t test was applied at 5% significance level. No significant difference was verified between treatment groups at any of the moments. There were reductions in clotting time (CT and clot formation time (CFT, with increase in maximum lysis (ML until the moment D9-MT. Evaluation through INTEM® reagent presented prolongations of CT and CFT with reduction of α angle and ML starting from D16 and D19. Similarly, aPTT presented significant differences between moments pre- (D0, 3 and 9 and post- (D16 and 19 anticoagulant and surgical treatment. The platelet numbers were diminished at moments D16 and

  18. Comprehensive Characterization of Palygorskite from Torrejon el Rubio (Spain) Based on Experimental Techniques and Theoretical DFT Studies

    International Nuclear Information System (INIS)

    Fernandez, A.M.; Timon, V.; Cubero, J. J.; Sanchez-Ledesma, D. M.; Gutierrez-Nebot, L.; Martinez, J. J.; Romero, C.; Labajo, M.; Melon, A.; Barrios, I.

    2013-01-01

    New data about the physico-chemical, microstructural and crystal-chemical properties of the mineral paligorskite from Torrejon el Rubio (Caceres, Spain) were obtained by a combination of experimental techniques (XRD, FRX, FTIR, TG-DSC, SEM and chemical analyses), as well as geometry optimization by means of the Density Functional Theory (DFT). This study demonstrates the applicability of the mixed theoretical-experimental work to characterize and understand the properties of clay minerals used in technological applications and environmental remediation. (Author)

  19. Comprehensive Characterization of Palygorskite from Torrejon el Rubio (Spain) Based on Experimental Techniques and Theoretical DFT Studies

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, A.M.; Timon, V.; Cubero, J. J.; Sanchez-Ledesma, D. M.; Gutierrez-Nebot, L.; Martinez, J. J.; Romero, C.; Labajo, M.; Melon, A.; Barrios, I.

    2013-10-01

    New data about the physico-chemical, microstructural and crystal-chemical properties of the mineral paligorskite from Torrejon el Rubio (Caceres, Spain) were obtained by a combination of experimental techniques (XRD, FRX, FTIR, TG-DSC, SEM and chemical analyses), as well as geometry optimization by means of the Density Functional Theory (DFT). This study demonstrates the applicability of the mixed theoretical-experimental work to characterize and understand the properties of clay minerals used in technological applications and environmental remediation. (Author)

  20. Benchmark Evaluation of HTR-PROTEUS Pebble Bed Experimental Program

    International Nuclear Information System (INIS)

    Bess, John D.; Montierth, Leland; Köberl, Oliver

    2014-01-01

    Benchmark models were developed to evaluate 11 critical core configurations of the HTR-PROTEUS pebble bed experimental program. Various additional reactor physics measurements were performed as part of this program; currently only a total of 37 absorber rod worth measurements have been evaluated as acceptable benchmark experiments for Cores 4, 9, and 10. Dominant uncertainties in the experimental keff for all core configurations come from uncertainties in the 235 U enrichment of the fuel, impurities in the moderator pebbles, and the density and impurity content of the radial reflector. Calculations of k eff with MCNP5 and ENDF/B-VII.0 neutron nuclear data are greater than the benchmark values but within 1% and also within the 3σ uncertainty, except for Core 4, which is the only randomly packed pebble configuration. Repeated calculations of k eff with MCNP6.1 and ENDF/B-VII.1 are lower than the benchmark values and within 1% (~3σ) except for Cores 5 and 9, which calculate lower than the benchmark eigenvalues within 4σ. The primary difference between the two nuclear data libraries is the adjustment of the absorption cross section of graphite. Simulations of the absorber rod worth measurements are within 3σ of the benchmark experiment values. The complete benchmark evaluation details are available in the 2014 edition of the International Handbook of Evaluated Reactor Physics Benchmark Experiments

  1. Experimental evaluation of gonadotoxical action of diazolin

    Directory of Open Access Journals (Sweden)

    Breydak O.A.

    2016-12-01

    Full Text Available Evaluation of gonadotoxic effect of diazolin was conducted according to the methodical recommendations. "Methods of experimental studies to establish thresholds of action of industrial poisons on the generative function for the purpose of hygienic regulation". Experiments were carried out on nonlinear white male rats. The preparation was introduced intragastrically within 72 days in a dose of 100 mg / kg (experimental group 1 and 20 mg / kg (2 experimental group, which made up 1/100DL50 and 1/500 DL50. For the assessment of sexual glands microscopic studies of the testes (external examination, weight, size, functional and morphological parameters were used. The parameters obtained during experiments were compared with the results of the control group and values of standards in laboratory animals. Influence of diazolin in the dose of 100 mg/kg (1/100 DL50 resulted in the increase in the total number of sperm cells with simultaneous decrease of their mobility, redox processes, osmotic and acid resistance. However, these changes did not reach statistical significance. Number of dead sperm cells and their pathological forms and indicators of semen-forming epithelium were within the control. Diazolin in the dose of 20 mg/kg (1/500 DL50 and 100 mg/kg (1/100 DL50 shows no gonadotoxical action.

  2. A Discrete Scatterer Technique for Evaluating Electromagnetic Scattering from Trees

    Science.gov (United States)

    2016-09-01

    Trees by DaHan Liao Approved for public release; distribution is unlimited. NOTICES Disclaimers The findings...for Evaluating Electromagnetic Scattering from Trees by DaHan Liao Sensors and Electron Devices Directorate, ARL...Technique for Evaluating Electromagnetic Scattering from Trees 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S

  3. Evaluation of radiology as a tool to diagnose pulmonic lesions in calves, for example prior to experimental infection studies

    DEFF Research Database (Denmark)

    Tegtmeier, Conny; Arnbjerg, J.

    2000-01-01

    The aim of the study was to evaluate radiology as a technique to visualize pulmonary lesions in young calves, e.g. as a selection criterion for research animals in order to eliminate animals with lung lesions Drier to experimental studies of pneumonia. Five calves with acute clinical signs...... of pneumonia were included in a direct comparative study of radiological and post mortem findings. Also, a number of animals with no signs of pneumonia were included as controls. The study revealed good agreement between the radiological and post mortem findings. Thus, in conclusion, radiology should...

  4. Evaluation of mfcc estimation techniques for music similarity

    DEFF Research Database (Denmark)

    Jensen, Jesper Højvang; Christensen, Mads Græsbøll; Murthi, Manohar

    2006-01-01

    Spectral envelope parameters in the form of mel-frequencycepstral coefficients are often used for capturing timbral information of music signals in connection with genre classification applications. In this paper, we evaluate mel-frequencycepstral coefficient (MFCC) estimation techniques, namely...... independent linear prediction and MVDR spectral estimators did not exhibit any statistically significant improvement over MFCCs based on the simpler FFT....

  5. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

    Science.gov (United States)

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-03-01

    To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2 = 0.92 versus r2 = 0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p < 0.05). MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.

  6. Evaluation of a Small-Group Technique as a Teacher Training Instrument. Final Report.

    Science.gov (United States)

    Whipple, Babette S.

    An exploratory study was designed to determine whether the use of a new, small group technique adds significantly to the level of training in early childhood education. Two groups of five student teachers learned the technique and were then evaluated. The evaluation procedure was designed to measure changes in their educational objectives, their…

  7. Experimental demonstration of the finite measurement time effect on the Feynman-{alpha} technique

    Energy Technology Data Exchange (ETDEWEB)

    Wallerbos, E.J.M.; Hoogenboom, J.E

    1998-09-01

    The reactivity of a subcritical system is determined by fitting two different theoretical models to a measured Feynman-{alpha} curve. The first model is the expression usually found in the literature, which can be shown to be the expectation value of the experimental quality if the measurement time is infinite. The second model is a new expression which is the expectation value of the experimental quantity for a finite measurement time. The reactivity inferred with the new model is seen to be independent of the length of the fitting interval, whereas the reactivity inferred with the conventional model is seen to vary. This difference demonstrates the effect of the finite measurement time. As a reference, the reactivity is also measured with the pulsed-neutron source method. It is seen to be in good agreement with the reactivity obtained with the Feynman-{alpha} technique when the new expression is applied.

  8. Optimization technique applied to interpretation of experimental data and research of constitutive laws

    International Nuclear Information System (INIS)

    Grossette, J.C.

    1982-01-01

    The feasibility of identification technique applied to one dimensional numerical analysis of the split-Hopkinson pressure bar experiment is proven. A general 1-D elastic-plastic-viscoplastic computer program was written down so as to give an adequate solution for elastic-plastic-viscoplastic response of a pressure bar subjected to a general Heaviside step loading function in time which is applied over one end of the bar. Special emphasis is placed on the response of the specimen during the first microseconds where no equilibrium conditions can be stated. During this transient phase discontinuity conditions related to wave propagation are encountered and must be carefully taken into account. Having derived an adequate numerical model, then Pontryagin identification technique has been applied in such a way that the unknowns are physical parameters. The solutions depend mainly on the selection of a class of proper eigen objective functionals (cost functions) which may be combined so as to obtain a convenient numerical objective function. A number of significant questions arising in the choice of parameter adjustment algorithms are discussed. In particular, this technique leads to a two point boundary value problem which has been solved using an iterative gradient like technique usually referred to as a double operator gradient method. This method combines the classical Fletcher-Powell technique and a partial quadratic technique with an automatic parameter step size selection. This method is much more efficient than usual ones. Numerical experimentation with simulated data was performed to test the accuracy and stability of the identification algorithm and to determine the most adequate type and quantity of data for estimation purposes

  9. Development of the staffing evaluation technique for mental tasks of the advanced main control room

    International Nuclear Information System (INIS)

    Hsieh Tsungling; Yang Chihwei; Lin Chiuhsiangjoe

    2011-01-01

    The key goals of staffing and qualifications review element are to ensure that the right numbers of people with the appropriate skills and abilities are available to support plant operations and events. If the staffing level is too few, excessive stress that caused human errors possibly will be placed on the operators. Accordingly, this study developed a staffing evaluation technique based on CPM-GOMS for the mental tasks such as operations in the advanced main control room. A within-subject experiment was designed to examine the validity of the staffing evaluation technique. The results indicated the performance of evaluated staffing level via the staffing evaluation technique was significantly higher than that of non-evaluated staffing level; thus, validity of the staffing evaluation technique can be accepted. Finally, the implications for managerial practice on the findings of this study were discussed. (author)

  10. Experimental evaluation of cooling efficiency of the high performance cooling device

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  11. Experimental evaluation of cooling efficiency of the high performance cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitna 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  12. Means of Ensuring Information Security and Experimental Study of the Efficiency of Forensic Handwriting Techniques

    Directory of Open Access Journals (Sweden)

    Sergey Dmitrievich Kulik

    2013-06-01

    Full Text Available This article deals with the special means, which allow to protect the information in the document. They are an integral part of the automated tools of ensuring the information security. It is proposed the use of a special input device PC Notes Taker. The results of experimental verification of the effectiveness of forensic handwriting techniques are described.

  13. Segmentation Techniques for Expanding a Library Instruction Market: Evaluating and Brainstorming.

    Science.gov (United States)

    Warren, Rebecca; Hayes, Sherman; Gunter, Donna

    2001-01-01

    Describes a two-part segmentation technique applied to an instruction program for an academic library during a strategic planning process. Discusses a brainstorming technique used to create a list of existing and potential audiences, and then describes a follow-up review session that evaluated the past years' efforts. (Author/LRW)

  14. New test techniques to evaluate near field effects for supersonic store carriage and separation

    Science.gov (United States)

    Sawyer, Wallace C.; Stallings, Robert L., Jr.; Wilcox, Floyd J., Jr.; Blair, A. B., Jr.; Monta, William J.; Plentovich, Elizabeth B.

    1989-01-01

    Store separation and store carriage drag studies were conducted. A primary purpose is to develop new experimental methods to evaluate near field effects of store separation and levels of store carriage drag associated with a variety of carriage techniques for different store shapes and arrangements. Flow field measurements consisting of surface pressure distributions and vapor screen photographs are used to analyze the variations of the store separation characteristics with cavity geometry. Store carriage drag measurements representative of tangent, semi-submerged, and internal carriage installations are presented and discussed. Results are included from both fully metric models and models with only metric segments (metric pallets) and the relative merits of the two are discussed. Carriage drag measurements for store installations on an aircraft parent body are compared both with prediction methods and with installations on a generic parent body.

  15. Daily-diary evaluated side-effects of conformal versus conventional prostatic cancer radiotherapy technique

    International Nuclear Information System (INIS)

    Widmark, A.; Fransson, P.; Franzen, L.; Littbrand, B.; Henriksson, R.

    1997-01-01

    Conventional 4-field box radiotherapy technique induces high morbidity for patients with localized prostatic cancer. Using a patient daily diary, the present study compared side-effects after conventional radiotherapy with conformal radiotherapy for prostate cancer. Fifty-eight patients treated with the conventional technique (with or without sucralfate) were compared with 72 patients treated with conformal technique. The patient groups were compared with an age-matched control population. Patients treated with conformal technique were also evaluated regarding acute and late urinary problems. Results showed that patients treated with conformal technique reported significantly fewer side-effects as compared with conventional technique. Patients treated with sucralfate also showed slightly decreased intestinal morbidity in comparison to non-sucralfate group. Acute and late morbidity evaluated by the patients was decreased after conformal radiotherapy as compared with the conventional technique. Sucralfate may be of value if conformal radiotherapy is used for dose escalation in prostatic cancer patients. (orig.)

  16. EVALUATION OF THE METERED-DOSE INHALER TECHNIQUE AMONG HEALTHCARE PROVIDERS

    Directory of Open Access Journals (Sweden)

    E. Nadi F. Zeraati

    2005-07-01

    Full Text Available Poor inhaler technique is a common problem both in asthmatic patients and healthcare providers, which contributes to poor asthma control. This study was performed to evaluate the adequacy of metered-dose inhaler (MDI technique in a sample of physicians and nurses practicing in hospitals of Hamadan University of Medical Sciences. A total of 173 healthcare providers voluntary participated in this study. After the participants answered a questionnaire aimed at identifying their involvement in MDI prescribing and counseling, a trained observer assessed their MDI technique using a checklist of nine steps. Of the 173 participants, 35 (20.2% were physicians and 138 (79.8% were nurses. Only 12 participants (6.93% performed all steps correctly. Physicians performed essential steps significantly better than nurses (85.7% vs. 63.8%, P < 0.05. The majority of healthcare providers responsible for instructing patients on the correct MDI technique were unable to perform this technique correctly, indicating the need for regular formal training programs on inhaler techniques.

  17. Techniques to Evaluate Dental Erosion: A Systematic Review of Literature.

    Science.gov (United States)

    Joshi, Mahasweta; Joshi, Nikhil; Kathariya, Rahul; Angadi, Prabhakar; Raikar, Sonal

    2016-10-01

    This article reviews different techniques for evaluating dental erosion, weighs the advantages and disadvantages of these techniques, and presents the latest trends in the study of dental erosion. In May 2014, an initial search was carried out in the PubMed/MEDLINE database of indexed journals from 1975 to 2013 using the following keywords: dental erosion; dental erosion In-vitro; and dental erosion in-vivo. Bibliographic citations from the papers found were then used to find other useful sources. The authors categorize the techniques into three classes: in-vitro, in-vivo and in-vitro/in-vivo. The article discusses the instrumentation required to use each of these techniques, as well as their rationale, merits and applications. The emergence of in-vitro/in-vivo techniques offers the potential to accurately quantify tooth wear in clinical situations. Cross-sectional as well as longitudinal studies show that these techniques will improve diagnosis, treatment planning and management of dental erosion.

  18. Development of a new technique for experimental evaluation of the fuel element's subchannel mixing

    International Nuclear Information System (INIS)

    Silin, Nicolas; Delmastro, Dario; Juanico, Luis

    2004-01-01

    In this work, the development of a new experimental method for the measurement of mixing between the cooling subchannels of nuclear fuel elements by using thermal traces, is presented.The method has been proved on a reduced test section with very positive results, having demonstrated its simplicity and low cost.Because it is suitable for heterogeneous and compact subchannels (asArgentinean fuels) with high water flows in simple and affordable tests at atmospheric pressure, this new method is specially well suited for the design of fuel elements, while it offers advantages over other methods of mixing measurement [es

  19. Technique of measuring and evaluating the R3E dia. 112 experimental fuel element

    International Nuclear Information System (INIS)

    Stanc, S.; Badiar, S.

    1974-10-01

    The charging is considered of the R3E experimental fuel element having a diameter of 112 mm which will serve the simultaneous temperature measurement on 15 sites and neutron flux measurement on 7 sites aimed at verifying the improved R3-type fuel element with extended cladding and a new toroidal spacing. The temperature will be measured using jacket thermocouples while neutron flux will be measured by self-powered detectors. The methods are described of checking the measuring chain by determining the loop resistance of the thermocouples and SPN detectors in order to verify the correctness of the measured data. (J.B.)

  20. Experimental and theoretical contributions to X-ray phase-contrast techniques for medical imaging; Contributions experimentales et theoriques aux techniques de contraste de phase pour l'imagerie medicale par rayons X

    Energy Technology Data Exchange (ETDEWEB)

    Diemoz, P.C.

    2011-02-28

    Several X-ray phase-contrast techniques have recently been developed. Unlike conventional X-ray methods, which measure the absorption properties of the tissues, these techniques derive contrast also from the modulation of the phase produced by the sample. Since the phase shift can be significant even for small details characterized by weak or absent absorption, the achievable image contrast can be greatly increased, notably for the soft biological tissues. These methods are therefore very promising for applications in the medical domain. The aim of this work is to contribute to a deeper understanding of these techniques, in particular propagation-based imaging (PBI), analyzer-based imaging (ABI) and grating interferometry (GIFM), and to study their potential and the best practical implementation for medical imaging applications. An important part of this work is dedicated to the use of mathematical algorithms for the extraction, from the acquired images, of quantitative sample information (the absorption, refraction and scattering sample properties). In particular, five among the most known algorithms based on the geometrical optics approximation have been theoretically analysed and experimentally compared, in planar and tomographic modalities, by using geometrical phantoms and human bone-cartilage and breast samples. A semi-quantitative method for the acquisition and reconstruction of tomographic images in the ABI and GIFM techniques has also been proposed. The validity conditions are analyzed in detail and the method, enabling a considerable simplification of the imaging procedure, has been experimentally checked on phantoms and human samples. Finally, a theoretical and experimental comparison of the PBI, ABI and GIFM techniques is presented. The advantages and drawbacks of each of these techniques are discussed. The results obtained from this analysis can be very useful for determining the most adapted technique for a given application. (author)

  1. X-ray computer tomography, ultrasound and vibrational spectroscopic evaluation techniques of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Baldock, Clive

    2004-01-01

    Since Gore et al published their paper on Fricke gel dosimetry, the predominant method of evaluation of both Fricke and polymer gel dosimeters has been magnetic resonance imaging (MRI). More recently optical computer tomography (CT) has also been a favourable evaluation method. Other techniques have been explored and developed as potential evaluation techniques in gel dosimetry. This paper reviews these other developments

  2. Evaluation of modified Dennis parasitological technique for diagnosis of bovine fascioliasis.

    Science.gov (United States)

    Correa, Stefanya; Martínez, Yudy Liceth; López, Jessika Lissethe; Velásquez, Luz Elena

    2016-02-23

    Bovine fascioliasis causes important economic losses, estimated at COP$ 12,483 billion per year; its prevalence is 25% in dairy cattle. Parasitological techniques are required for it diagnosis. The Dennis technique, modified in 2002, is the one used in Colombia, but its sensitivity, specificity and validity are not known.  To evaluate the validity and performance of the modified Dennis technique for diagnosis of bovine fascioliasis using as reference test the observation of parasites in the liver.  We conducted a diagnostic evaluation study. We selected a convenience sample of discarded bovines sacrificed between March and June, 2013, in Frigocolanta for the study. We collected 25 g of feces from each animal and their liver and bile ducts were examined for Fasciola hepatica. The sensitivity, specificity, predictive positive value, predictive negative value, and validity index were calculated with 95% confidence intervals. The post-mortem evaluation was used as the gold standard.  We analyzed 180 bovines. The sensitivity and specificity of the modified Dennis technique were 73.2% (95% CI=58.4% - 87.9%) and 84.2% (95% CI= 77.7% - 90.6%), respectively. The positive predictive value was 57.7% (95% CI= 43.3% - 72.1%) and the negative one 91.4% (95% CI= 86.2% - 96.6%). The prevalence of bovine fascioliasis was 22.8% (95% CI= 16.4% - 29.2%).  The validity and the performance of the modified Dennis technique were higher than those of the traditional one, which makes it a good screening test for diagnosing fascioliasis for population and prevalence studies and during animal health campaigns.

  3. An overview of experimental techniques developed during hydrogeological investigations at Reskajeage Quarry, Cornwall

    International Nuclear Information System (INIS)

    Bolt, J.E.; Pascoe, D.M.; Watkins, V.M.B.

    1991-09-01

    In fractured rocks, the transport of dissolved radionuclides which may be released from the near-field of a radioactive waste repository will take place dominantly through the three dimensional network of fractures. Assessments of groundwater flow and radionuclide transport from an underground repository use continuum models, such as NAMMU, to predict radionuclide transport. To complement this approach, water flow and transport in fractured rock is being investigated at a more detailed level, using fracture network modelling. A test site, at Reskajeage Quarry in Cornwall, is currently being used to provide experimental data on flow and transport in fractured rock, to improve confidence in this modelling approach. This report describes the range of experimental techniques that have been used to obtain data on the positions, orientations and hydraulic properties of individual fractures in the slate. Also, brief descriptions of the design of a series of transport tests are given. The results of this work are described in a series of Nirex Safety Series Reports. (Author)

  4. An overview of experimental techniques developed during hydrogeological investigations at Reskajeage Quarry, Cornwall

    International Nuclear Information System (INIS)

    Bolt, J.E.; Pascoe, D.M.; Watkins, V.M.B.

    1991-09-01

    In fractured rocks, the transport of dissolved radionuclides which may be released from the near-field of a radioactive waste repository will take place dominantly through the three-dimensional network of fractures. Assessments of groundwater flow and radionuclide transport from an underground repository use continuum models, such as NAMMU, to predict radionuclide transport. To complement this approach, water flow and transport in fractured rock is being investigated at a more detailed level, using fracture network modelling. A test side, at Reskajeage Quarry in Cornwall, is currently being used to provide experimental data on flow and transport in fractured rock, to improve confidence in this modelling approach. This report describes the range of experimental techniques that have been used to obtain data on the positions, orientations and hydraulic properties of individual fractures in the slate. Also, brief descriptions of the design of a series of transport tests are given. The results of this work are described in a series of Nirex Safety Series Reports. (author)

  5. Methods and benefits of experimental seismic evaluation of nuclear power plants. Final report

    International Nuclear Information System (INIS)

    1979-07-01

    This study reviews experimental techniques, instrumentation requirements, safety considerations, and benefits of performing vibration tests on nuclear power plant containments and internal components. The emphasis is on testing to improve seismic structural models. Techniques for identification of resonant frequencies, damping, and mode shapes, are discussed. The benefits of testing with regard to increased damping and more accurate computer models are oulined. A test plan, schedule and budget are presented for a typical PWR nuclear power plant

  6. Methods and benefits of experimental seismic evaluation of nuclear power plants. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-01

    This study reviews experimental techniques, instrumentation requirements, safety considerations, and benefits of performing vibration tests on nuclear power plant containments and internal components. The emphasis is on testing to improve seismic structural models. Techniques for identification of resonant frequencies, damping, and mode shapes, are discussed. The benefits of testing with regard to increased damping and more accurate computer models are oulined. A test plan, schedule and budget are presented for a typical PWR nuclear power plant.

  7. Development of human factors evaluation techniques for nuclear power plants

    International Nuclear Information System (INIS)

    Oh, I.S.; Lee, Y.H.; Lee, J.W.; Sim, B.S.

    1999-01-01

    This paper describes development of an operator task simulation analyzer and human factors evaluation techniques performed recently at Korea Atomic Energy Research Institute. The first is the SACOM (Simulation Analyzer with a Cognitive Operator Model) for the assessment of task performance by simulating control room operation. The latter has two objectives: to establish a human factors experiment facility, the Integrated Test Facility (ITF), and to establish techniques for human factors experiments. (author)

  8. Novel experimental measuring techniques required to provide data for CFD validation

    International Nuclear Information System (INIS)

    Prasser, H.-M.

    2008-01-01

    CFD code validation requires experimental data that characterize the distributions of parameters within large flow domains. On the other hand, the development of geometry-independent closure relations for CFD codes have to rely on instrumentation and experimental techniques appropriate for the phenomena that are to be modelled, which usually requires high spatial and time resolution. The paper reports about the use of wire-mesh sensors to study turbulent mixing processes in single-phase flow as well as to characterize the dynamics of the gas-liquid interface in a vertical pipe flow. Experiments at a pipe of a nominal diameter of 200 mm are taken as the basis for the development and test of closure relations describing bubble coalescence and break-up, interfacial momentum transfer and turbulence modulation for a multi-bubble-class model. This is done by measuring the evolution of the flow structure along the pipe. The transferability of the extended CFD code to more complicated 3D flow situations is assessed against measured data from tests involving two-phase flow around an asymmetric obstacle placed in a vertical pipe. The obstacle, a half-moon-shaped diaphragm, is movable in the direction of the pipe axis; this allows the 3D gas fraction field to be recorded without changing the sensor position. In the outlook, the pressure chamber of TOPFLOW is presented, which will be used as the containment for a test facility, in which experiments can be conducted in pressure equilibrium with the inner atmosphere of the tank. In this way, flow structures can be observed by optical means through large-scale windows even at pressures of up to 5 MPa. The so-called 'Diving Chamber' technology will be used for Pressurized Thermal Shock (PTS) tests. Finally, some important trends in instrumentation for multi-phase flows will be given. This includes the state-of-art of X-ray and gamma tomography, new multi-component wire-mesh sensors, and a discussion of the potential of other non

  9. Novel experimental measuring techniques required to provide data for CFD validation

    International Nuclear Information System (INIS)

    Prasser, H.M.

    2007-01-01

    CFD code validation requires experimental data that characterize distributions of parameters within large flow domains. On the other hand, the development of geometry-independent closure relations for CFD codes have to rely on instrumentation and experimental techniques appropriate for the phenomena that are to be modelled, which usually requires high spatial and time resolution. The presentation reports about the use of wire-mesh sensors to study turbulent mixing processes in the single-phase flow as well as to characterize the dynamics of the gas-liquid interface in a vertical pipe flow. Experiments at a pipe of a nominal diameter of 200 mm are taken as the basis for the development and test of closure relations describing bubble coalescence and break-up, interfacial momentum transfer and turbulence modulation for a multi-bubble-class model. This is done by measuring the evolution of the flow structure along the pipe. The transferability of the extended CFD code to more complicated 3D flow situations is assessed against measured data from tests involving two-phase flow around an asymmetric obstacle placed in a vertical pipe. The obstacle, a half-moon-shaped diaphragm, is movable in the direction of the pipe axis; this allows the 3D gas fraction field to be recorded without changing the sensor position. In the outlook, the pressure chamber of TOPFLOW is presented, which will be used as the containment for a test facility, in which experiments can be conducted in pressure equilibrium with the inner atmosphere of the tank. In this way, flow structures can be observed by optical means through large-scale windows even at pressures of up to 5 MPa. The so-called 'Diving Chamber' technology will be used for Pressurized Thermal Shock (PTS) tests. Finally, some important trends in instrumentation for multi-phase flows will be given. This includes the state-of-art of X-ray and gamma tomography, new multi-component wire-mesh sensors, and a discussion of the potential of

  10. Neutron cross section and covariance data evaluation of experimental data for 27Al

    International Nuclear Information System (INIS)

    Li Chunjuan; Liu Jianfeng; Liu Tingjin

    2006-01-01

    The evaluation of neutron cross section and covariance data for 27 Al in the energy range from 210 keV to 20 MeV was carried out on the basis of the experimental data mainly taken from EXFOR library. After the experimental data and their errors were analyzed, selected and corrected, SPCC code was used to fit the data and merge the covariance matrix. The evaluated neutron cross section data and covariance matrix for 27 Al given can be collected for the evaluated library and also can be used as the basis of theoretical calculation concerned. (authors)

  11. Comparative Evaluation of Three In Vitro Techniques in the ...

    African Journals Online (AJOL)

    Purpose: The study was designed to evaluate the consistency of interpretation of results of interaction between ampicillin and ciprofloxacin against S. aureus and E. coli using three in vitro techniques. Methods: The interaction between ampicillin and ciprofloxacin was studied using three in vitro methods- Checkerboard ...

  12. Techniques developed to evaluate the fracture toughness offast breeder reactor duct

    International Nuclear Information System (INIS)

    Huang, F.H.; Wire, G.L.

    1979-01-01

    Large changes in strength and ductility of metals after irradiation are known to occur. The fracture toughness of irradiated metals, which is related to the combined strength and ductility of a material, may be significantly reduced and the potential for unstable crack extension increased. Therefore, the resistance of cladding and duct materials to fracture after exposure to fast neutron environments is of concern. Existing Type 316 stainless steel irradiated ducts are relatively thin and since this material retains substantial ductility, even after irradiation, the fracture behavior of the duct material cannot be analyzed by linear elastic fracture mechanics techniques. Instead, the multispecimen R-curve method and J-integral analysis were used to develop an experimental approach to evaluate the fracture toughness of thin breeder reactor duct materials irradiated at elevated temperatures. Alloy A-286 was chosen for these experiments because the alloy exhibits elastic/plastic behavior and the fracture toughness data of thicker (12 mm) specimens were available for comparison. Technical problems associated with specimen buckling and remote handling were treated in this work. The results are discussed in terms of thickness criterion for plane strain

  13. Minimum intensity projection technique in the evaluation of pulmonary emphysema

    International Nuclear Information System (INIS)

    Ishii, Chikako; Tada, Shinpei; Fukuda, Kunihiko; Hayashi, Naganobu

    2000-01-01

    Clinically diagnosed 30 pulmonary emphysema patients were evaluated with helical CT. From 10 mm thickness and 10 mm/sec table speed helical CT date set, minimum intensity projection (Min-IP) were generated. Min-IP coronal images were well demonstrated distribution and degree of emphysema. Compared to the high resolution CT images (2 mm thickness), Min-IP images were as same as well evaluated the disease. Min-IP technique seem to be useful for evaluate distribution and degree of pulmonary emphysema. (author)

  14. Integrity Evaluation of Railway Bogie Using Infrared Thermography Technique

    International Nuclear Information System (INIS)

    Kim, Jeong Guk

    2011-01-01

    The lock-in thermography was employed to evaluate the integrity of railway bogies. Prior to the actual application on railway bogies, in order to assess the detectability of known flaws, the calibration reference panel was prepared with various dimensions of artificial flaws. The panel was composed of structural steel, which was the same material with actual bogies. Through lock-in thermography evaluation, the optimal frequency of heat source was determined for the best flaw detection. Based on the defects information, the actual defect assessments on railway bogie were conducted with different types of railway bogies, which were used for the current operation. In summary, the defect assessment results with thermography method showed a good agreement as compared with the conventional inspection techniques. Moreover, it was found that the novel infrared thermography technique could be an effective way for the inspection and the detection of surface defects on bogies since the infrared thermography method provided rapid and non-contact mode for the investigation of railway bogies

  15. Experimental model for evaluation of the cutaneous sensitivity of the abdomen

    Directory of Open Access Journals (Sweden)

    Andreia Bufoni Farah

    2004-12-01

    Full Text Available The purpose of this study is to report an experimental model to evaluate several modalities of sensibility and to map the areas of the abdominal wall with decreased sensibility after abdominoplasty. Patients were divided in two groups: in the control group, patients had no previous abdominal incisions and patients of the experimental group had been undergone abdominoplasty. The sensibility evaluation of patients from the experimental group was made from 12 to 60 months after the operation. The abdominal skin was divided into twelve areas; nine of them were above the abdominoplasty incision and three below it. Sensibility to superficial touch, superficial pain, hot and cold temperature, vibration was tested and recorded as positive if the patient mentioned that he felt the stimulation or negative. Sensibility to pressure was tested with the use of different weights; therefore, a value was obtained when the patient felt the pressure. A specific test was used to evaluate each modality of sensibility. The experimental model designed to test skin sensibility after abdominoplasty showed to be feasible in patients.O objetivo deste estudo é relatar e divulgar um modelo experimental para avaliar diversas modalidades de sensibilidade e mapear as áreas da parede abdominal nas quais ocorre diminuição da sensibilidade após abdominoplastia. Dois grupos de pacientes foram estudados: no grupo controle, as paciente não apresentavam incisões abdominais prévias e as pacientes do grupo experimental tinham sido submetidas a abdominoplastia. A avaliação da sensibilidade das pacientes do grupo experimental foi realizada de 12 a 60 meses após a cirurgia. A pele abdominal foi dividida em doze áreas, sendo nove acima e três abaixo da cicatriz da abdominoplastia. As sensibilidades ao toque superficial, dor superficial, ao calor e frio, vibração foram testadas e registradas como positive se a paciente referisse que sentiu o estímulo ou, caso o contr

  16. The Effectiveness of FRESH Technique to Teach Descriptive Paragraph

    Directory of Open Access Journals (Sweden)

    Faisal Faisal

    2013-11-01

    Full Text Available This study was aimed at knowing the effectiveness of FRESH technique in teaching descriptive paragraph. The method of this study was quasi experimental method. This study was conducted at one of the state madrasah aliyah in academic year 2012/2013. The total sample of this study was 78 respondents divided into two groups: the control class with no treatment and the experimental class with FRESH technique. The data collection technique used essay tests for pre-test and post-test. The evaluation covered content, organization, vocabulary, style, and mechanic. After data analyses, the students in the experimental class had better achievement than those in the control class. The result of t-test computation was 1.968, with t-table value = 1.664 at the significant level α = 0.05. The t-test result was higher than the value of t-table (1.968 > 1.664. It meant that the hypothesis was accepted or FRESH technique was effective in teaching descriptive paragraph to the students of that school in academic year 2012/2013.

  17. Performance Evaluation of Frequent Subgraph Discovery Techniques

    Directory of Open Access Journals (Sweden)

    Saif Ur Rehman

    2014-01-01

    Full Text Available Due to rapid development of the Internet technology and new scientific advances, the number of applications that model the data as graphs increases, because graphs have highly expressive power to model a complicated structure. Graph mining is a well-explored area of research which is gaining popularity in the data mining community. A graph is a general model to represent data and has been used in many domains such as cheminformatics, web information management system, computer network, and bioinformatics, to name a few. In graph mining the frequent subgraph discovery is a challenging task. Frequent subgraph mining is concerned with discovery of those subgraphs from graph dataset which have frequent or multiple instances within the given graph dataset. In the literature a large number of frequent subgraph mining algorithms have been proposed; these included FSG, AGM, gSpan, CloseGraph, SPIN, Gaston, and Mofa. The objective of this research work is to perform quantitative comparison of the above listed techniques. The performances of these techniques have been evaluated through a number of experiments based on three different state-of-the-art graph datasets. This novel work will provide base for anyone who is working to design a new frequent subgraph discovery technique.

  18. Statistical methods of evaluating and comparing imaging techniques

    International Nuclear Information System (INIS)

    Freedman, L.S.

    1987-01-01

    Over the past 20 years several new methods of generating images of internal organs and the anatomy of the body have been developed and used to enhance the accuracy of diagnosis and treatment. These include ultrasonic scanning, radioisotope scanning, computerised X-ray tomography (CT) and magnetic resonance imaging (MRI). The new techniques have made a considerable impact on radiological practice in hospital departments, not least on the investigational process for patients suspected or known to have malignant disease. As a consequence of the increased range of imaging techniques now available, there has developed a need to evaluate and compare their usefulness. Over the past 10 years formal studies of the application of imaging technology have been conducted and many reports have appeared in the literature. These studies cover a range of clinical situations. Likewise, the methodologies employed for evaluating and comparing the techniques in question have differed widely. While not attempting an exhaustive review of the clinical studies which have been reported, this paper aims to examine the statistical designs and analyses which have been used. First a brief review of the different types of study is given. Examples of each type are then chosen to illustrate statistical issues related to their design and analysis. In the final sections it is argued that a form of classification for these different types of study might be helpful in clarifying relationships between them and bringing a perspective to the field. A classification based upon a limited analogy with clinical trials is suggested

  19. Theoretical and Experimental Optical Evaluation and Comparison of Symmetric 2D CPC and V-Trough Collector for Photovoltaic Applications

    Directory of Open Access Journals (Sweden)

    Damasen Ikwaba Paul

    2015-01-01

    Full Text Available This paper presents theoretical and experimental optical evaluation and comparison of symmetric Compound Parabolic Concentrator (CPC and V-trough collector. For direct optical properties comparison, both concentrators were deliberately designed to have the same geometrical concentration ratio (1.96, aperture area, absorber area, and maximum concentrator length. The theoretical optical evaluation of the CPC and V-trough collector was carried out using a ray-trace technique while the experimental optical efficiency and solar energy flux distributions were analysed using an isolated cell PV module method. Results by simulation analysis showed that for the CPC, the highest optical efficiency was 95% achieved in the interval range of 0° to ±20° whereas the highest outdoor experimental optical efficiency was 94% in the interval range of 0° to ±20°. For the V-tough collector, the highest optical efficiency for simulation and outdoor experiments was about 96% and 93%, respectively, both in the interval range of 0° to ±5°. Simulation results also showed that the CPC and V-trough exhibit higher variation in non-illumination intensity distributions over the PV module surface for larger incidence angles than lower incidence angles. On the other hand, the maximum power output for the cells with concentrators varied depending on the location of the cell in the PV module.

  20. Sexual Violence Prevention through Bystander Education: An Experimental Evaluation

    Science.gov (United States)

    Banyard, Victoria L.; Moynihan, Mary M.; Plante, Elizabethe G.

    2007-01-01

    The current study used an experimental design to evaluate a sexual violence prevention program based on a community of responsibility model that teaches women and men how to intervene safely and effectively in cases of sexual violence before, during, and after incidents with strangers, acquaintances, or friends. It approaches both women and men as…

  1. Evaluation of the DSC technique in the determination of the terminal temperature solubility of hydrogen in Zircaloy 4

    International Nuclear Information System (INIS)

    Vizcaino, Pablo; Banchik, Abraham D.

    1999-01-01

    The determination of the terminal temperature solubility of hydrogen in the zirconium alloys is a matter of our interest, since the hydride precipitation in these materials make them susceptible to the delay hydrogen cracking (DHC). Nowadays efforts are directed to the determination of this parameter on irradiated materials. In this frame we have begun a program to determine these curves on irradiated zirconium alloys like Zircaloys, Zr 2.5% Nb, Zr 1% Nb, zirconium sponge and high oxygen zirconium with different microstructures using the differential scanning calorimeter technique. The earlier task that we have imposed to us is the evaluation the reproducibility of this technique and the influence of the heating and cooling rates on the results. With these objectives we have initiated this work measuring the terminal temperature solubility (TTS) in unirradiated recrystallized and cold worked Zircaloy-4. We have found that the reproducibility of the technique is good; the average values (TSSD) and (TSSP) agree within the experimental error and the dispersions are low. Variance analysis indicates that the values of TSSD and TSSP do not depend on the heating and cooling rates. Within the rank analyzed the differences in the measurements are only possible to be attributed to statistical and/or experimental errors. The obtained curves of solubility show to a good agreement with the values obtained by others authors until 200 ppm (weight) of hydrogen. Similar comparisons between precipitation curves have not been made in regard to which these values depend on the maximum temperature reached in the experience. (author)

  2. Theory of Feynman-alpha technique with masking window for accelerator-driven systems

    International Nuclear Information System (INIS)

    Kitamura, Yasunori; Misawa, Tsuyoshi

    2017-01-01

    Highlights: • A theory of the modified Feynman-alpha technique for the ADS was developed. • The experimental conditions under which this technique works were discussed. • It is expected this technique is applied to the subcriticality monitor for the ADS. - Abstract: Recently, a modified Feynman-alpha technique for the subcritical system driven by periodically triggered neutron bursts was developed. One of the main features of this technique is utilization of a simple formula that is advantageous in evaluating the subcriticality. However, owing to the absence of the theory of this technique, this feature has not been fully investigated yet. In the present study, a theory of this technique is provided. Furthermore, the experimental conditions under which the simple formula works are discussed to apply this technique to the subcriticality monitor for the accelerator-driven system.

  3. Evaluating the effectiveness of behavior change techniques in health-related behavior: a scoping review of methods used.

    Science.gov (United States)

    Michie, Susan; West, Robert; Sheals, Kate; Godinho, Cristina A

    2018-03-01

    Behavior change interventions typically contain multiple potentially active components: behavior change techniques (BCTs). Identifying which specific BCTs or BCT combinations have the potential to be effective for a given behavior in a given context presents a major challenge. The aim of this study was to review the methods that have been used to identify effective BCTs for given behaviors in given contexts and evaluate their strengths and limitations. A scoping review was conducted of studies that had sought to identify effective BCTs. Articles referring to "behavio(u)r change technique(s)" in the abstract/text were located, and ones that involved identification of effective BCTs were selected. The methods reported were coded. The methods were analyzed in general terms using "PASS" criteria: Practicability (facility to apply the method appropriately), Applicability (facility to generalize from findings to contexts and populations of interest), Sensitivity (facility to identify effective BCTs), and Specificity (facility to rule out ineffective BCTs). A sample of 10% of the studies reviewed was then evaluated using these criteria to assess how far the strengths and limitations identified in principle were borne out in practice. One hundred and thirty-five studies were identified. The methods used in those studies were experimental manipulation of BCTs, observational studies comparing outcomes in the presence or absence of BCTs, meta-analyses of BCT comparisons, meta-regressions evaluating effect sizes with and without specific BCTs, reviews of BCTs found in effective interventions, and meta-classification and regression trees. The limitations of each method meant that only weak conclusions could be drawn regarding the effectiveness of specific BCTs or BCT combinations. Methods for identifying effective BCTs linked to target behavior and context all have important inherent limitations. A strategy needs to be developed that can systematically combine the strengths of

  4. National seminar on non-destructive evaluation techniques: proceedings cum souvenir

    International Nuclear Information System (INIS)

    Dutta, N.G.; Kulkarni, P.G.; Purushotham, D.S.C.

    1994-01-01

    This volume contains selected papers presented at the National Seminar on Non-Destructive Evaluation Techniques held at Bhabha Atomic Research Centre, Mumbai during December 8-9, 1994. The papers covered a wide spectrum of non-destructive evaluation activities including that for quality assurance of various nuclear components and structures with the focal theme being computerization and robotics. The papers relevant to INIS are indexed separately

  5. Experimental and evaluated data on the discrete level excitation function of the 238U(n,n') reaction

    International Nuclear Information System (INIS)

    Simakov, S.P.

    1991-01-01

    Experimental data on the 238 U excitation function are compiled and analyzed. The experimental data are compared with the evaluated data from the BNAB, ENDF/B-IV and ENDL-78 evaluated data libraries. It is shown that the BNAB evaluated data are in good agreement with the existing experimental data, including new results from recent experiments. (author). 26 refs, 2 figs, 2 tabs

  6. Impact of corpus domain for sentiment classification: An evaluation study using supervised machine learning techniques

    Science.gov (United States)

    Karsi, Redouane; Zaim, Mounia; El Alami, Jamila

    2017-07-01

    Thanks to the development of the internet, a large community now has the possibility to communicate and express its opinions and preferences through multiple media such as blogs, forums, social networks and e-commerce sites. Today, it becomes clearer that opinions published on the web are a very valuable source for decision-making, so a rapidly growing field of research called “sentiment analysis” is born to address the problem of automatically determining the polarity (Positive, negative, neutral,…) of textual opinions. People expressing themselves in a particular domain often use specific domain language expressions, thus, building a classifier, which performs well in different domains is a challenging problem. The purpose of this paper is to evaluate the impact of domain for sentiment classification when using machine learning techniques. In our study three popular machine learning techniques: Support Vector Machines (SVM), Naive Bayes and K nearest neighbors(KNN) were applied on datasets collected from different domains. Experimental results show that Support Vector Machines outperforms other classifiers in all domains, since it achieved at least 74.75% accuracy with a standard deviation of 4,08.

  7. Contribution of computer science to the evaluation of experimental data

    International Nuclear Information System (INIS)

    Steuerwald, J.

    1978-11-01

    The GALE data acquisition system and EDDAR data processing system, used at Max-Planck-Institut fuer Plasmaphysik, serve to illustrate some of the various ways in which computer science plays a major role in developing the evaluation of experimental data. (orig.) [de

  8. Scoping studies of tritium handling in a tokamak experimental power reactor

    International Nuclear Information System (INIS)

    Cherdack, R.; Watson, J.S.; Clinton, S.D.; Fisher, P.W.

    1975-01-01

    Tritium handling techniques in an experimental fusion power reactor (EPR) are evaluated to determine the requirements of the system and to compare different equipment and techniques for meeting those requirements. Tritium process equipment is needed to (1) evacuate and maintain a vacuum in the plasma vessel and the neutral beam injectors, (2) purify and recycle tritium and deuterium for the plasma fuel cycle, (3) recover tritium from experimental breeding modules, and (4) provide tritium containment and atmospheric cleanup. A development program is outlined to develop and demonstrate the required techniques and equipment and to permit confident design of an EPR for operation by the mid-1980s

  9. Experimental validation of energy parameters in parabolic trough collector with plain absorber and analysis of heat transfer enhancement techniques

    Science.gov (United States)

    Bilal, F. R.; Arunachala, U. C.; Sandeep, H. M.

    2018-01-01

    The quantum of heat loss from the receiver of the Parabolic Trough Collector is considerable which results in lower thermal efficiency of the system. Hence heat transfer augmentation is essential which can be attained by various techniques. An analytical model to evaluate the system with bare receiver performance was developed using MATLAB. The experimental validation of the model resulted in less than 5.5% error in exit temperature using both water and thermic oil as heat transfer fluid. Further, heat transfer enhancement techniques were incorporated in the model which included the use of twisted tape inserts, nanofluid, and a combination of both for further enhancement. It was observed that the use of evacuated glass cover in the existing setup would increase the useful heat gain up to 5.3%. Fe3O4/H2O nanofluid showed a maximum enhancement of 56% in the Nusselt number for the volume concentration of 0.6% at highest Reynolds number. Similarly, twisted tape turbulators (with twist ratio of 2) taken alone with water exhibited 59% improvement in Nusselt number. Combining both the heat transfer augmentation techniques at their best values revealed the Nusselt number enhancement up to 87%. It is concluded that, use of twisted tape with water is the best method for heat transfer augmentation since it gives the maximum effective thermal efficiency amongst all for the range of Re considered. The first section in your paper

  10. Evaluating and comparing imaging techniques: a review and classification of study designs

    International Nuclear Information System (INIS)

    Freedman, L.S.

    1987-01-01

    The design of studies to evaluate and compare imaging techniques are reviewed. Thirteen principles for the design of studies of diagnostic accuracy are given. Because of the 'independence principle' these studies are not able directly to evaluate the contribution of a technique to clinical management. For the latter, the 'clinical value' study design is recommended. A classification of study designs is proposed in parallel with the standard classification of clinical trials. Studies of diagnostic accuracy are analogous to Phase II, whereas studies evaluating the contribution to clinical management correspond to the Phase III category. Currently the majority of published studies employ the Phase II design. More emphasis on Phase III studies is required. (author)

  11. Comparative evaluation of experimental and theoretical erosion resistance of materials upon electric pulse treatment

    International Nuclear Information System (INIS)

    Karpman, M.G.; Fetisov, G.P.; Bologov, D.V.

    1999-01-01

    Using the Palatnik criterion a comparative analysis is performed of the theoretical and experimental data on comparative electric erosion and erosion resistance of the electrodes and parts made of different materials upon their treatment using electric pulse technique. A reasonable qualitative agreement of the theoretical and experimental data indicates the possibility of using the Palatnik criterion to predict the serviceability of different pairs of the materials in conditions of electroerosion wear [ru

  12. Evaluating interfacial adhesion properties of Pt/Ti thin-film by using acousto-optic technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae Sung [Graduate School of Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of); Didie, David; Yoshida, Sanichiro [Dept. of Chemistry and Physics, Southeastern Louisiana University, Hammond (United States); Park, Ik Keun [Dept. of Mechanical and Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2016-06-15

    We propose an acousto-optic technique for the nondestructive evaluation of adhesion properties of a Pt/Ti thin-film interface. Since there are some problems encountered when using prevailing techniques to nondestructively evaluate the interfacial properties of micro/nano-scale thin-films, we applied an interferometer that combined the acoustic and optical methods. This technique is based on the Michelson interferometer but the resultant surface of the thin film specimen makes interference instead of the mirror when the interface is excited from the acoustic transducer at the driving frequency. The thin film shows resonance-like behavior at a certain frequency range, resulting in a low-contrast fringe pattern. Therefore, we represented quantitatively the change in fringe pattern as a frequency spectrum and discovered the possibility that the interfacial adhesion properties of a thin film can be evaluated using the newly proposed technique.

  13. Review of nuclear data improvement needs for nuclear radiation measurement techniques used at the CEA experimental reactor facilities

    Directory of Open Access Journals (Sweden)

    Destouches Christophe

    2016-01-01

    Full Text Available The constant improvement of the neutron and gamma calculation codes used in experimental nuclear reactors goes hand in hand with that of the associated nuclear data libraries. The validation of these calculation schemes always requires the confrontation with integral experiments performed in experimental reactors to be completed. Nuclear data of interest, straight as cross sections, or elaborated ones such as reactivity, are always derived from a reaction rate measurement which is the only measurable parameter in a nuclear sensor. So, in order to derive physical parameters from the electric signal of the sensor, one needs specific nuclear data libraries. This paper presents successively the main features of the measurement techniques used in the CEA experimental reactor facilities for the on-line and offline neutron/gamma flux characterizations: reactor dosimetry, neutron flux measurements with miniature fission chambers and Self Power Neutron Detector (SPND and gamma flux measurements with chamber ionization and TLD. For each technique, the nuclear data necessary for their interpretation will be presented, the main identified needs for improvement identified and an analysis of their impact on the quality of the measurement. Finally, a synthesis of the study will be done.

  14. Experimental study of natural two-phase flow circulation using a visualization technique; Estudo experimental da circulacao natural bifasica utilizando uma tecnica de visualizacao

    Energy Technology Data Exchange (ETDEWEB)

    Vinhas, Pedro A.M., E-mail: Pedro_mvinhas@poli.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Nuclear; Faccini, Jose L.H., E-mail: faccini@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Su, Jian, E-mail: sujian@lasme.coppe.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2013-07-01

    This paper presents an experimental study of natural two-phase flow in a circuit that simulates, on a smaller scale, a typical residual heat removal system of passive reactors APWR (Advanced Pressurized Water Reactor). The circuit was formed by a heater, a heat exchanger and piping. The experimental study was the application of a visualization technique, using a high speed camera, for measuring the size and speed of vapor bubbles generated in the heater with different power heating. The camera was positioned in the central region of the pipe connecting the heater to the heat exchanger, where there is a clear passage. The flow of images were processed and analyzed using commercial software that allowed the determination of the length and velocity of the bubbles. The results were then compared with correlations available in literature.

  15. QUALITY OF SERVICE ORIENTED WEB SERVICE SELECTION: AN EVALUATION OF TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Munjiah Nur Saadah

    2014-08-01

    Full Text Available Abstract In service-oriented computing, web services are the basic foundation that aims to facilitate building of business application in a more flexible and interoperable manner for enterprise collaboration. One of the most promising advantages of web service technology is the possibility of creating added-value services by combining existing ones. A key step for composing and executing services lies in the selection of the individual service to use. Much attention has been devoted to appropriate selection of service functionalities, but also the non-functional properties of the services play a key role. A web service selection technique must take as much as possible the important influencing aspects into account to the selection process in order to minimize the selection efforts. This paper evaluates several web service selection techniques published in literature with the focus on their contributions to web service selection. The evaluation results can be used as a basis for improving web service selection techniques and then simplifying the selection tasks.

  16. Double 90 Degrees Counterrotated End-to-End-Anastomosis: An Experimental Study of an Intestinal Anastomosis Technique.

    Science.gov (United States)

    Holzner, Philipp; Kulemann, Birte; Seifert, Gabriel; Glatz, Torben; Chikhladze, Sophia; Höppner, Jens; Hopt, Ulrich; Timme, Sylvia; Bronsert, Peter; Sick, Olivia; Zhou, Cheng; Marjanovic, Goran

    2015-06-01

    The aim of the article is to investigate a new anastomotic technique compared with standardized intestinal anastomotic procedures. A total of 32 male Wistar rats were randomized to three groups. In the Experimental Group (n = 10), the new double 90 degrees inversely rotated anastomosis was used, in the End Group (n = 10) a single-layer end-to-end anastomosis, and in the Side Group (n = 12) a single-layer side-to-side anastomosis. All anastomoses were done using interrupted sutures. On postoperative day 4, rats were relaparotomized. Bursting pressure, hydroxyproline concentration, a semiquantitative adhesion score and two histological anastomotic healing scores (mucosal healing according to Chiu and overall anastomotic healing according to Verhofstad) were collected. Most data are presented as median (range). p < 0.05 was considered significant. Anastomotic insufficiency occurred only in one rat of the Side Group. Median bursting pressure in the Experimental Group was 105 mm Hg (range = 72-161 mm Hg), significantly higher in the End Group (164 mm Hg; range = 99-210 mm Hg; p = 0.021) and lower in the Side Group by trend (81 mm Hg; range = 59-122 mm Hg; p = 0.093). Hydroxyproline concentration did not differ significantly in between the groups. The adhesion score was 2.5 (range = 1-3) in the Experimental Group, 2 (range = 1-2) in the End Group, but there were significantly more adhesions in the Side Group (range = 3-4); p = 0.020 versus Experimental Group, p < 0.001 versus End Group. The Chiu Score showed the worst mucosal healing in the Experimental Group. The overall Verhofstad Score was significantly worse (mean = 2.032; standard deviation [SD] = 0.842) p = 0.031 and p = 0.002 in the Experimental Group, compared with the Side Group (mean = 1.729; SD = 0.682) and the End Group (mean = 1.571; SD = 0.612). The new anastomotic technique is feasible and did not show any relevant complication. Even though it was superior to the side-to-side anastomosis by trend with

  17. The Development of Experimentation and Evidence Evaluation Skills at Preschool Age

    Science.gov (United States)

    Piekny, Jeanette; Grube, Dietmar; Maehler, Claudia

    2014-01-01

    Researchers taking a domain-general approach to the development of scientific reasoning long thought that the ability to engage in scientific reasoning did not develop until adolescence. However, more recent studies have shown that preschool children already have a basic ability to evaluate evidence and a basic understanding of experimentation. Data providing insights into when exactly in the preschool years significant gains in these abilities occur are scarce. Drawing on a sample of 138 preschool children, this longitudinal study therefore examined how children's ability to evaluate evidence and their understanding of experimentation develop between the ages of four and six. Findings showed that the ability to evaluate evidence was already well developed at age four and increased steadily and significantly over time as long as the pattern of covariation was perfect. In the case of imperfect covariation, the proportion of correct answers was low over the period of observation, but showed a significant increase between the ages of four and five. If the data did not allow relationship between variables to be inferred, the proportion of correct answers was low, with a significant increase between the ages of five and six. The children's understanding of experimentation increased significantly between the ages of five and six. The implications of these findings for age-appropriate science programs in preschool are discussed.

  18. Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.

    Science.gov (United States)

    Liu, David Yu; Cader, Fathima Nashmie; Abduo, Jaafar; Palamara, Joseph

    2017-12-29

    To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation. A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique using poly(vinyl siloxane) impression material. The impressions were poured with type IV dental stone to generate the test casts. A rosette strain gauge was bonded to the middle of the framework. As the framework retaining screws were tightened on each test cast, the developed strains were recorded until the completion of the tightening to 35 Ncm. The generated strains of the rosette strain gauge were used to calculate the maximum principal strain. A statistically significant difference was observed among the different impression techniques. The modified tray design impression technique was associated with the least framework strains, which indicates greater accuracy compared with the other techniques. There was no significant difference between the splinted and the nonsplinted impression techniques. The new tray design concept appeared to produce more accurate implant impressions than the other techniques. Despite the statistical difference among the impression techniques, the clinical significance of this difference is yet to be determined. © 2017 by the American College of Prosthodontists.

  19. Mechanical system diagnostics using vibration testing techniques

    Science.gov (United States)

    Mcleod, Catherine D.; Raju, P. K.; Crocker, M. J.

    1990-01-01

    The 'Cepstrum' technique of vibration-path identification allows the recovery of the transfer function of a system with little knowledge as to its excitation force, by means of a mathematical manipulation of the system output in conjunction with subtraction of part of the output and suitable signal processing. An experimental program has been conducted to evaluate the usefulness of this technique in the cases of simple, cantilever-beam and free-free plate structures as well as in that of a complex mechanical system. On the basis of the transfer functions thus recovered, it was possible to evaluate the shifts in the resonance frequencies of a structure due to the presence of defects.

  20. Experimental techniques of conversion coefficient measurements

    International Nuclear Information System (INIS)

    Hamilton, J.H.

    1975-01-01

    Discusses briefly the history of conversion electron spectra measurements, and the interpretation of the collected data. Then provides a comprehensive review of techniques presently available to measure the conversion coefficients. (Auth.)

  1. Sigmoid Colon Elongation Evaluation by Volume Rendering Technique

    Directory of Open Access Journals (Sweden)

    Atilla SENAYLI

    2011-06-01

    Full Text Available Sigmoid colons have various measurements, shapes, and configurations for individuals. In this subject there are rare clinical trials to answer the question of sigmoidal colon maldevelopment predicting a risk for volvulus. Therefore, sigmoid colon measurement may be beneficial to decide for volvulus. In a study, sigmoid colon diameters were evaluated during abdominal surgeries and it was found that median length was 47 cm and median vertical mesocolon length was 13 cm. We report a 14-year-old female patient who has a sigmoidal colon measured as nearly 54 cm. We used tomographic equipments for this evaluation. We know that MRI technique was used for this purpose but, there has not been data for MRI predicting the sigmoidal volvulus. We hope that our findings by this evaluation can contribute to insufficient literature of sigmoidal elongation. [J Contemp Med 2011; 1(2.000: 71-73

  2. Evaluation of leucocytes labelling technique with 99m Tc - HMPAO

    International Nuclear Information System (INIS)

    Moraes, D.W.; Marinho, N.S.; Rezende, M.E.X.; Buchpiguel, C.A.; Rockmann, T.M.B.

    1992-01-01

    An evaluation of the leukocytes labelling technique with HMPAO- 99m Tc, using low volume of blood and keeping the labelling efficiency and cellular viability in compatible levels with those preconized by the literature is presented. (C.G.C.)

  3. Metallographic techniques for evaluation of Thermal Barrier Coatings produced by Electron Beam Physical Vapor Deposition

    International Nuclear Information System (INIS)

    Kelly, Matthew; Singh, Jogender; Todd, Judith; Copley, Steven; Wolfe, Douglas

    2008-01-01

    Thermal Barrier Coatings (TBC) produced by Electron Beam Physical Vapor Deposition (EB-PVD) are primarily applied to critical hot section turbine components. EB-PVD TBC for turbine applications exhibit a complicated structure of porous ceramic columns separated by voids that offers mechanical compliance. Currently there are no standard evaluation methods for evaluating EB-PVD TBC structure quantitatively. This paper proposes a metallographic method for preparing samples and evaluating techniques to quantitatively measure structure. TBC samples were produced and evaluated with the proposed metallographic technique and digital image analysis for columnar grain size and relative intercolumnar porosity. Incorporation of the proposed evaluation technique will increase knowledge of the relation between processing parameters and material properties by incorporating a structural link. Application of this evaluation method will directly benefit areas of quality control, microstructural model development, and reduced development time for process scaling

  4. Innovative Hyperspectral Imaging-Based Techniques for Quality Evaluation of Fruits and Vegetables: A Review

    Directory of Open Access Journals (Sweden)

    Yuzhen Lu

    2017-02-01

    Full Text Available New, non-destructive sensing techniques for fast and more effective quality assessment of fruits and vegetables are needed to meet the ever-increasing consumer demand for better, more consistent and safer food products. Over the past 15 years, hyperspectral imaging has emerged as a new generation of sensing technology for non-destructive food quality and safety evaluation, because it integrates the major features of imaging and spectroscopy, thus enabling the acquisition of both spectral and spatial information from an object simultaneously. This paper first provides a brief overview of hyperspectral imaging configurations and common sensing modes used for food quality and safety evaluation. The paper is, however, focused on the three innovative hyperspectral imaging-based techniques or sensing platforms, i.e., spectral scattering, integrated reflectance and transmittance, and spatially-resolved spectroscopy, which have been developed in our laboratory for property and quality evaluation of fruits, vegetables and other food products. The basic principle and instrumentation of each technique are described, followed by the mathematical methods for processing and extracting critical information from the acquired data. Applications of these techniques for property and quality evaluation of fruits and vegetables are then presented. Finally, concluding remarks are given on future research needs to move forward these hyperspectral imaging techniques.

  5. INSTRUMENT FOR EVALUATION OF THE ADAPTED ABILITIES FROM THE ELEMENT OF BASKETBALL TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Goran Šekeljić

    2006-06-01

    Full Text Available The idea of the work is clearly defined, precise and objective instrument for evaluation of the adopted abilities from the elements of basketball technique. The intention is to cut into small fragments the chosen elements of technique which are going to be evaluated with numerical value of every piece itself. The model established in that way is possible to compare with motorical forms acquired by those who are been inquired. Every fragment of motorical form has precise numerical value on which basis is possible to quantify by simple numerical total the obtained level of sports- technical education. We consider possible to diminish the influence of subjectivity such as to form schoolmarks more objectivly by precise and high-quality system of evaluation on the basis of clearly cut into small pieces structures of elements of the complete technique. In that case we could talk about real expert evaluation. The results of the research have shown that the method of evaluation conceived in this way has given excellent metrics characteristics and that, statistically verified, has been more objective than the two other methods predicted in the experiment

  6. Evaluation of the microdialysis technique in the dog fat pad

    DEFF Research Database (Denmark)

    Stallknecht, Bente; Madsen, J; Galbo, H

    1999-01-01

    In the present study the microdialysis technique was evaluated in an isolated autoperfused dog fat pad. Concentrations of glucose, lactate, and glycerol were measured in interstitial fluid by microdialysis and simultaneously in arterial and adipose venous plasma. Adipose tissue blood flow...

  7. Root activity evaluation in tree crops using isotopic techniques

    International Nuclear Information System (INIS)

    Calvache, Marcelo

    1991-01-01

    This paper discusses the methdology used to evalute root activity of the crops utilizing the technique of soil injection with solutions marked with isotopes. Some of the experimental data obtained with coffee, citrus and oil palm are also presented. Ovel all, these tree crops present a higher root activity in soil layers close to the surface (0-20 cm) and to a distance from the trunk which varies with age, season and variety. The most important conclusions are: 1. The isotope injection technique using 3 2 P , 1 5 N , or 8 5 R b, allow direct and reliable determination of root activity in these tree crops. 2. Root activity of three crops depends on age of the tree, variety, moisture content of the soil and soil type. 3. Soil moisture is the most influencial factor affecting root activity. This is turn depends on the irrigation method employed. 4. From the practical view point, the best distance from the trunk to apply fertilizer in the one wich has highest root activity closest to the soil surface

  8. An experimental technique for the modelling of air flow movements in nuclear plant

    International Nuclear Information System (INIS)

    Ainsworth, R.W.; Hallas, N.J.

    1986-01-01

    This paper describes an experimental technique developed at Harwell to model ventilation flows in plant at 1/5th scale. The technique achieves dynamic similarity not only for forced convection imposed by the plant ventilation system, but also for the interaction between natural convection (from heated objects) and forced convection. The use of a scale model to study flow of fluids is a well established technique, relying upon various criteria, expressed in terms of dimensionless numbers, to achieve dynamic similarity. For forced convective flows, simulation of Reynolds number is sufficient, but to model natural convection and its interaction with forced convection, the Rayleigh, Grashof and Prandtl numbers must be simulated at the same time. This paper describes such a technique, used in experiments on a hypothetical glove box cell to study the interaction between forced and natural convection. The model contained features typically present in a cell, such as a man, motor, stairs, glove box, etc. The aim of the experiment was to study the overall flow patterns, especially around the model man 'working' at the glove box. The cell ventilation was theoretically designed to produce a downward flow over the face of the man working at the glove box. However, the results have shown that the flow velocities produced an upwards flow over the face of the man. The work has indicated the viability of modelling simultaneously the forced and natural convection processes in a cell. It has also demonstrated that simplistic assumptions cannot be made about ventilation flow patterns. (author)

  9. Evaluation of Uranium-235 Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kaspar, Tiffany C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dibert, Mark W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-23

    Monolithic U-Mo fuel plates are rolled to final fuel element form from the original cast ingot, and thus any inhomogeneities in 235U distribution present in the cast ingot are maintained, and potentially exaggerated, in the final fuel foil. The tolerance for inhomogeneities in the 235U concentration in the final fuel element foil is very low. A near-real-time, nondestructive technique to evaluate the 235U distribution in the cast ingot is required in order to provide feedback to the casting process. Based on the technical analysis herein, gamma spectroscopy has been recommended to provide a near-real-time measure of the 235U distribution in U-Mo cast plates.

  10. Demonstration and evaluation of recent air-sealing techniques in housing

    Energy Technology Data Exchange (ETDEWEB)

    Mayhew, W.J.

    1987-09-01

    The Airtight Drywall Approach (ADA) and the sealed polyethylene approach were developed as two distinct systems for reducing air leakage in housing. Builders have not totally accepted either method but have instead tended to borrow the most practical and cost-effective techniques and materials from each system and combined them into hybrid systems. This project evaluated current air-sealing techniques, developed refinements to some of those techniques and incorporated them into the construction of the Cold Climate Demonstration House (CCDH), a research and demonstration facility in Alberta. By comparing the effectiveness and practical use of different air and vapour retarder materials and techniques, it was found that for the air barrier, ADA materials and techniques were more easily installed. The resulting air seal was more reliable. However, until inspectors accept alkyd or vapor barrier paints as the vapor retarder, polyethylene is recommended. The construction techniques recommended in this report can be installed with a minimum of experience and with minimal involvement of other subtrades. The cost to provide an air/vapor barrier for a 1000 ft /sup 2/ bilevel with both levels fully developed (as demonstrated in the CCDH) was approximately $360. 26 figs.

  11. MONJU experimental data analysis and its feasibility evaluation to build up the standard data base for large FBR nuclear core design

    International Nuclear Information System (INIS)

    Sugino, K.; Iwai, T.

    2006-01-01

    MONJU experimental data analysis was performed by using the detailed calculation scheme for fast reactor cores developed in Japan. Subsequently, feasibility of the MONJU integral data was evaluated by the cross-section adjustment technique for the use of FBR nuclear core design. It is concluded that the MONJU integral data is quite valuable for building up the standard data base for large FBR nuclear core design. In addition, it is found that the application of the updated data base has a possibility to considerably improve the prediction accuracy of neutronic parameters for MONJU. (authors)

  12. Combined Multi-criteria Evaluation Stage Technique as an Agro Waste Evaluation Indicator for Polymeric Composites: Date Palm Fibers as a Case Study

    Directory of Open Access Journals (Sweden)

    Faris M. AL-Oqla

    2014-06-01

    Full Text Available The final features of natural fiber composites (NFCs depend on the integrated characteristics of their constituents. In the industry today, natural agro waste fibers are evaluated using a limited number of criteria. In this work, a combined multi-criteria evaluation stage technique (CMCEST is introduced as a simple efficient systematic indicator to enhance evaluation of the available natural agro wastes for polymeric composites. In this proposed technique, criteria affecting the proper selection of natural agro waste fibers were combined and divided into sequence stages as follows: single-evaluation-criterion (SEC, combined-double-evaluation-criterion (CDEC, combined-triple-evaluation-criterion (CTEC, etc. These stages are based on combined physical, mechanical, and economic evaluation criteria and can be extended to several further stages to include other beneficial characteristics. The effectiveness of this technique was demonstrated by evaluating coir, date palm, jute, hemp, kenaf, and oil palm fibers simultaneously. This combined evaluation criteria can lead to more informative decisions regarding selection of the most suitable fiber type for polymeric composites. The CMCEST enhancements can reveal new potential fiber types through better evaluation schemes, help achieve clearer indications of the capabilities of available agro wastes to enhance composites, and determine proper ecological waste management practices. Utilizing the proposed technique, the date palm fiber type was found to be quite promising due to beneficial characteristics revealed in CTEC, which provides a reasonable, cheap, and eco-friendly alternative material suitable for different applications.

  13. Evaluation and Selection of Best Priority Sequencing Rule in Job Shop Scheduling using Hybrid MCDM Technique

    Science.gov (United States)

    Kiran Kumar, Kalla; Nagaraju, Dega; Gayathri, S.; Narayanan, S.

    2017-05-01

    Priority Sequencing Rules provide the guidance for the order in which the jobs are to be processed at a workstation. The application of different priority rules in job shop scheduling gives different order of scheduling. More experimentation needs to be conducted before a final choice is made to know the best priority sequencing rule. Hence, a comprehensive method of selecting the right choice is essential in managerial decision making perspective. This paper considers seven different priority sequencing rules in job shop scheduling. For evaluation and selection of the best priority sequencing rule, a set of eight criteria are considered. The aim of this work is to demonstrate the methodology of evaluating and selecting the best priority sequencing rule by using hybrid multi criteria decision making technique (MCDM), i.e., analytical hierarchy process (AHP) with technique for order preference by similarity to ideal solution (TOPSIS). The criteria weights are calculated by using AHP whereas the relative closeness values of all priority sequencing rules are computed based on TOPSIS with the help of data acquired from the shop floor of a manufacturing firm. Finally, from the findings of this work, the priority sequencing rules are ranked from most important to least important. The comprehensive methodology presented in this paper is very much essential for the management of a workstation to choose the best priority sequencing rule among the available alternatives for processing the jobs with maximum benefit.

  14. Evaluation of the low dose cardiac CT imaging using ASIR technique

    Science.gov (United States)

    Fan, Jiahua; Hsieh, Jiang; Deubig, Amy; Sainath, Paavana; Crandall, Peter

    2010-04-01

    Today Cardiac imaging is one of the key driving forces for the research and development activities of Computed Tomography (CT) imaging. It requires high spatial and temporal resolution and is often associated with high radiation dose. The newly introduced ASIR technique presents an efficient method that offers the dose reduction benefits while maintaining image quality and providing fast reconstruction speed. This paper discusses the study of image quality of the ASIR technique for Cardiac CT imaging. Phantoms as well as clinical data have been evaluated to demonstrate the effectiveness of ASIR technique for Cardiac CT applications.

  15. Review Article : Utilization of Environmental Radiochemistry Techniques for Selection and Evaluation of Nuclear Facility Sites

    International Nuclear Information System (INIS)

    Atta, E.R.; Madbouly, A.M.; Zakaria, Kh.M.

    2016-01-01

    This research review puts necessary considerations on the available environmental radiochemistry techniques for selection and evaluation of a nuclear facility sites.The main bjective in site evaluation for nuclear facilities in terms of nuclear safety is to protect the site workers, the public and the environment from the effects of ionizing radiation release from nuclear facilities due to accidents. The extreme sensitivity and speed of radiochemical methods make their applications of considerable importance in several fields and they have found many uses. Information about the existed radioactivity in the different nuclear facilities is an essential requirement for their environmental assessment. It is necessary to estimate the various radioactivity levels in the environment through qualitative and quantitative analytical techniques and to assess the potential effects of the nuclear facility in the region by considering the characteristics of sites.The siting and site evaluation requirements are discussed. Emphasis was given to types of radiochemical techniques used for characterization of the site parameters which determine the potential hazards of the site on the facility and the facility on the site. Emphasis has been also given to the quantitative and qualitative analysis of naturally occurring radionuclides for monitoring and control .There are some techniques employed such as radioactive tracer technique, liquid scintillation technique, gamma spectrometry technique, neutron activation analysis technique, fluorimetric technique and isotope hydrology technique.

  16. Evaluation of frequency-dependent ultrasound attenuation in transparent medium using focused shadowgraph technique

    Science.gov (United States)

    Iijima, Yukina; Kudo, Nobuki

    2017-07-01

    Acoustic fields of a short-pulsed ultrasound propagating through a transparent medium with ultrasound attenuation were visualized by the focused shadowgraph technique. A brightness waveform and its spatial integrations were derived from a visualized field image and compared with a pressure waveform measured by a membrane hydrophone. The experimental results showed that first-order integration of the brightness wave has good agreement with the pressure waveforms. Frequency-dependent attenuation of the pulse propagating through castor oil was derived from brightness and pressure waveforms, and attenuation coefficients determined from focused shadowgraphy and hydrophone techniques showed good agreement. The results suggest the usefulness of the shadowgraph technique not only for the visualization of ultrasound fields but also for noncontact estimation of rough pressure waveforms and correct ultrasound attenuation.

  17. Review of Micro/Nano Nondestructive Evaluation Technique (II): Measurement of Acoustic Properties

    International Nuclear Information System (INIS)

    Kim, Chung Seok; Park, Ik Keun

    2012-01-01

    The present paper reviews the micro and nano nondestructive evaluation(NDE) technique that is possible to investigate the surface and measure the acoustic properties. The technical theory, features and applications of the ultrasonic atomic force microscopy(UAFM) and scanning acoustic microscopy(SAM) are illustrated. Especially, these technologies are possible to evaluate the mechanical properties in micro/nano structure and surface through the measurement of acoustic properties in addition to the observation of surface and subsurface. Consequently, it is thought that technique developments and applications of these micro/nano NDE in advanced industrial parts together with present nondestructive industry are widely possible hereafter.

  18. Standard evaluation techniques for containment and surveillance radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1982-01-01

    Evaluation techniques used at Los Alamos for personnel and vehicle radiation monitors that safeguard nuclear material determine the worst-case sensitivity. An evaluation tests a monitor's lowest sensitivity regions with sources that have minimum emission rates. The result of our performance tests are analyzed as a binomial experiment. The number of trials that are required to verify the monitor's probability of detection is determined by a graph derived from the confidence limits for a binomial distribution. Our testing results are reported in a way that characterizes the monitor yet does not compromise security by revealing its routine performance for detecting process materials

  19. Neutron cross section and covariance data evaluation of experimental data for {sup 27}Al

    Energy Technology Data Exchange (ETDEWEB)

    Chunjuan, Li; Jianfeng, Liu [Physics Department , Zhengzhou Univ., Zhengzhou (China); Tingjin, Liu [China Nuclear Data Center, China Inst. of Atomic Energy, Beijing (China)

    2006-07-15

    The evaluation of neutron cross section and covariance data for {sup 27}Al in the energy range from 210 keV to 20 MeV was carried out on the basis of the experimental data mainly taken from EXFOR library. After the experimental data and their errors were analyzed, selected and corrected, SPCC code was used to fit the data and merge the covariance matrix. The evaluated neutron cross section data and covariance matrix for {sup 27}Al given can be collected for the evaluated library and also can be used as the basis of theoretical calculation concerned. (authors)

  20. Prospect Evaluation as an Emerging Pre-Evaluation Technique in the Case of Great Plains Wheat Producers’ Use of Web 2.0

    Directory of Open Access Journals (Sweden)

    Nicholas R. Brown

    2016-06-01

    Full Text Available We introduce a pre-evaluation technique, prospect evaluation, in the case of Great Plains wheat producers’ practices with Web 2.0. We emerged prospect evaluation as a pre-evaluation technique, expanding the role of evaluative logic and reasoning into the ideation phase of project and product development to close the risk gap between project idea and implementation. Prospect evaluation serves as a prequel to the well-established developmental, formative, and summative evaluation models. We implemented the prospect evaluation technique in the context of iWheat, a USDA-funded Web 2.0 project (currently known as myFields, http://myfields.info/dashboard. Wheat producers were comfortable using computers; however, they conceptualized the Internet with a Web 1.0 mindset that depends on a centralized model of development and delivery of content. Wheat producers were not comfortable actively co-creating useful information for the betterment of community, a fundamental underpinning of Web 2.0 advancement. Extension specialists and educators should focus on the rewards of contributing to Web 2.0 sites and proceed in diffusing Web 2.0 tools to the wheat producers. Prospect evaluation was sufficient for helping project leaders bridge the risk gap and move forward with the project.

  1. MATLAB platform for Monte Carlo planning and dosimetry experimental evaluation; Plataforma Matlab para planificacion Monte Carlo y evaluacion dosimetrica experimental

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, J. A.; Ureba, A.; Jimenez-Ortega, E.; Pereira-Barbeiro, A. R.; Leal, A.

    2013-07-01

    A new platform for the full Monte Carlo planning and an independent experimental evaluation that it can be integrated into clinical practice. The tool has proved its usefulness and efficiency and now forms part of the flow of work of our research group, the tool used for the generation of results, which are to be suitably revised and are being published. This software is an effort of integration of numerous algorithms of image processing, along with planning optimization algorithms, allowing the process of MCTP planning from a single interface. In addition, becomes a flexible and accurate tool for the evaluation of experimental dosimetric data for the quality control of actual treatments. (Author)

  2. Lung MRI for experimental drug research

    International Nuclear Information System (INIS)

    Beckmann, Nicolau; Cannet, Catherine; Karmouty-Quintana, Harry; Tigani, Bruno; Zurbruegg, Stefan; Ble, Francois-Xavier; Cremillieux, Yannick; Trifilieff, Alexandre

    2007-01-01

    Current techniques to evaluate the efficacy of potential treatments for airways diseases in preclinical models are generally invasive and terminal. In the past few years, the flexibility of magnetic resonance imaging (MRI) to obtain anatomical and functional information of the lung has been explored with the scope of developing a non-invasive approach for the routine testing of drugs in models of airways diseases in small rodents. With MRI, the disease progression can be followed in the same animal. Thus, a significant reduction in the number of animals used for experimentation is achieved, as well as minimal interference with their well-being and physiological status. In addition, under certain circumstances the duration of the observation period after disease onset can be shortened since the technique is able to detect changes before these are reflected in parameters of inflammation determined using invasive procedures. The objective of this article is to briefly address MRI techniques that are being used in experimental lung research, with special emphasis on applications. Following an introduction on proton techniques and MRI of hyperpolarized gases, the attention is shifted to the MRI analysis of several aspects of lung disease models, including inflammation, ventilation, emphysema, fibrosis and sensory nerve activation. The next subject concerns the use of MRI in pharmacological studies within the context of experimental lung research. A final discussion points towards advantages and limitations of MRI in this area

  3. A analytical comparison of different estimators for the density distribution of the catalyst in a experimental riser by a gammametric technique

    International Nuclear Information System (INIS)

    Lima, Emerson Alexandre de Oliveira; Dantas Carlos C.; Melo, Silvio de Barros; Santos, Valdemir Alexandre dos

    2005-01-01

    In this paper, we solve the following questions: what will be the estimate of the r = r (x, y, z) function format? Which method would describe the density distribution function more precisely? Which is the best estimator? Also, once the ρ=ρ(x, y, z) format and the approximation technique is defined, comes the experimental arrangement and pass length configuration, which are the next problems to be solved. Finding the best parameter estimation for the ρ=ρ(x, y, z) function according to the C pass lengths and their spatial configuration. The latter is required to define the ρ=ρ(x, y, z) function resolution and the mechanical scanning movements of the arrangement. Such definitions will be implemented for an automate arrangement, by a computational program, to further development of the reconstruction of catalyst density distribution on experimental risers.. The precision evaluation was finally compared to the arrangement geometry that yields the best pass length spatial configuration. The results are shown in graphics for the two known density distributions. As a conclusion, the parameters for an automate arrangement design, are given under the required precision for the catalyst distribution reconstruction. (author)

  4. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De [Chonnam Univ. Medical School, Kwangju (Korea, Republic of)

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis.

  5. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    International Nuclear Information System (INIS)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis

  6. Optimization and evaluation of clarithromycin floating tablets using experimental mixture design.

    Science.gov (United States)

    Uğurlu, Timucin; Karaçiçek, Uğur; Rayaman, Erkan

    2014-01-01

    The purpose of the study was to prepare and evaluate clarithromycin (CLA) floating tablets using experimental mixture design for treatment of Helicobacter pylori provided by prolonged gastric residence time and controlled plasma level. Ten different formulations were generated based on different molecular weight of hypromellose (HPMC K100, K4M, K15M) by using simplex lattice design (a sub-class of mixture design) with Minitab 16 software. Sodium bicarbonate and anhydrous citric acid were used as gas generating agents. Tablets were prepared by wet granulation technique. All of the process variables were fixed. Results of cumulative drug release at 8th h (CDR 8th) were statistically analyzed to get optimized formulation (OF). Optimized formulation, which gave floating lag time lower than 15 s and total floating time more than 10 h, was analyzed and compared with target for CDR 8th (80%). A good agreement was shown between predicted and actual values of CDR 8th with a variation lower than 1%. The activity of clarithromycin contained optimizedformula against H. pylori were quantified using well diffusion agar assay. Diameters of inhibition zones vs. log10 clarithromycin concentrations were plotted in order to obtain a standard curve and clarithromycin activity.

  7. Development and experimental evaluation of theoretical models for ion cyclotron resonance frequency heating of tokamak plasmas

    International Nuclear Information System (INIS)

    Mantsinen, M.

    1999-01-01

    Heating with electromagnetic waves in the ion cyclotron range of frequencies (ICRF) is a well-established method for auxiliary heating of present-day tokamak plasmas and is envisaged as one of the main heating techniques for the International Thermonuclear Experimental Reactor (ITER) and future reactor plasmas. In order to predict the performance of ICRF heating in future machines, it is important to benchmark present theoretical modelling with experimental results on present tokamaks. This thesis reports on development and experimental evaluation of theoretical models for ICRF heating at the Joint European Torus (JET). Several ICRF physics effects and scenarios have been studied. Direct importance to the ITER is the theoretical analysis of ICRF heating experiments with deuterium-tritium (D-T) plasmas. These experiments clearly demonstrate the potential of ICRF heating for auxiliary heating of reactor plasmas. In particular, scenarios with potential for good bulk ion heating and enhanced D-T fusion reactivity have been identified. Good bulk ion heating is essential for reactor plasmas in order to obtain a high ion temperature and a high fusion reactivity. In JET good bulk ion heating with ICRF waves has been achieved in high-performance discharges by adding ICRF heating to neutral beam injection. In these experiments, as in other JET discharges where damping at higher harmonics of the ion cyclotron frequency takes place, so-called finite Larmor radius (FLR) effects play an important role. Due to FLR effects, the resonating ion velocity distribution function can have a strong influence on the power deposition. Evidence for this effect has been obtained from the third harmonic deuterium heating experiments. Because of FLR effects, the wave-particle interaction can also become weak at certain ion energies, which prevents resonating ions from reaching higher energies. When interacting with the wave, an ion receives not only a change in energy but also a change in

  8. Experimental determination of nuclear reaction rates (n,γ) by the gamma-rays capture spectrometry technique

    International Nuclear Information System (INIS)

    Lucatero, M.A.

    1976-01-01

    The technique of the gamma-rays capture spectrometry was used in the experimental determination of nuclear reaction rates of the type (n,γ). This technique consists in the incidence of a thermal neutrons collimated beam upon a sample, detecting the capture spectrum of gamma rays emitted at a solid fixed angle. In the determination of the efficiency curve intrinsic to the detection electronic system the reactions 199 Hg(n,γ) 200 Hg, 56 Fe(n,γ) 57 Fe and 63 Cu(n,γ) 64 Cu were used with the energy of the gamma rays capture of 5.976, 7.635 and 7.915 Mev respectively, through the irradiation of standard samples of Hg(175.3g), Fe(110.4g) and Cu(108.5g) of cylindrical geometry the two former and parallelepiped the latter. The problem concerning the corrections due to the thermal neutrons flux depression, the gammas auto-attenuation, and the geometric factor due to the cylindrical and parallelepiped geometry are involved in the data process. The experimental determination of the reaction 35 Cl(n,γ) 36 Cl rate was made through the observation of the gamma caputre of 6.111 Mev when a sample of CaCl 2 of cylindrical geometry was irradiated. This rate can be favorably compared with the reaction rate determined theoretically. (author)

  9. Experimental Effects of Student Evaluations Coupled with Collaborative Consultation on College Professors' Instructional Skills

    NARCIS (Netherlands)

    Knol, M.H.; in 't Veld, R.; Vorst, H.C.M.; van Driel, J.H.; Mellenbergh, G.J.

    2013-01-01

    This experimental study concerned the effects of repeated students’ evaluations of teaching coupled with collaborative consultation on professors’ instructional skills. Twenty-five psychology professors from a Dutch university were randomly assigned to either a control group or an experimental

  10. Experimental evaluation of the primary damage process: neutron energy effects

    Energy Technology Data Exchange (ETDEWEB)

    Goland, A.N.

    1979-01-01

    Experimental evaluation of the neutron energy dependnece of the primary damage stage depends upon a number of theoretical concepts. This state can only be observed after low- or perhaps ambient-temperature, low-fluence irradiations. The primary recoil energy spectrum, which determines the character of the displacement cascades, can be calculated if dosimetry has provided an accurate neutron spectrum. A review of experimental results relating neutron-energy effects shows that damage energy or damage energy cross section has often been a reliable correlation parameter for primary damage state experiments. However, the forthcoming emphasis on higher irradiation temperatures, more complex alloys and microstructural evolution has fostered a search for additional meaningful correlation parameters.

  11. Evaluation of conformal radiotherapy techniques through physics and biologic criteria

    International Nuclear Information System (INIS)

    Bloch, Jonatas Carrero

    2012-01-01

    In the fight against cancer, different irradiation techniques have been developed based on technological advances and aiming to optimize the elimination of tumor cells with the lowest damage to healthy tissues. The radiotherapy planning goal is to establish irradiation technical parameters in order to achieve the prescribed dose distribution over the treatment volumes. While dose prescription is based on radiosensitivity of the irradiated tissues, the physical calculations on treatment planning take into account dosimetric parameters related to the radiation beam and the physical characteristics of the irradiated tissues. To incorporate tissue's radiosensitivity into radiotherapy planning calculations can help particularize treatments and establish criteria to compare and elect radiation techniques, contributing to the tumor control and the success of the treatment. Accordingly, biological models of cellular response to radiation have to be well established. This work aimed to study the applicability of using biological models in radiotherapy planning calculations to aid evaluating radiotherapy techniques. Tumor control probability (TCP) was studied for two formulations of the linear-quadratic model, with and without repopulation, as a function of planning parameters, as dose per fraction, and of radiobiological parameters, as the α/β ratio. Besides, the usage of biological criteria to compare radiotherapy techniques was tested using a prostate planning simulated with Monte Carlo code PENELOPE. Afterwards, prostate planning for five patients from the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, USP, using three different techniques were compared using the tumor control probability. In that order, dose matrices from the XiO treatment planning system were converted to TCP distributions and TCP-volume histograms. The studies performed allow the conclusions that radiobiological parameters can significantly influence tumor control

  12. The digital geometric phase technique applied to the deformation evaluation of MEMS devices

    International Nuclear Information System (INIS)

    Liu, Z W; Xie, H M; Gu, C Z; Meng, Y G

    2009-01-01

    Quantitative evaluation of the structure deformation of microfabricated electromechanical systems is of importance for the design and functional control of microsystems. In this investigation, a novel digital geometric phase technique was developed to meet the deformation evaluation requirement of microelectromechanical systems (MEMS). The technique is performed on the basis of regular artificial lattices, instead of a natural atom lattice. The regular artificial lattices with a pitch ranging from micrometer to nanometer will be directly fabricated on the measured surface of MEMS devices by using a focused ion beam (FIB). Phase information can be obtained from the Bragg filtered images after fast Fourier transform (FFT) and inverse fast Fourier transform (IFFT) of the scanning electronic microscope (SEM) images. Then the in-plane displacement field and the local strain field related to the phase information will be evaluated. The obtained results show that the technique can be well applied to deformation measurement with nanometer sensitivity and stiction force estimation of a MEMS device

  13. Evaluation of different parasitological techniques in the diagnosis of canine helminthiasis

    Directory of Open Access Journals (Sweden)

    Marcelle Temporim Novaes

    2015-12-01

    Full Text Available ABSTRACT. Novaes M.T. & Martins I.V.F. [Evaluation of different parasitological techniques in the diagnosis of canine helminthiasis.] Avaliação de diferentes técnicas parasitológicas no diagnóstico de helmintoses caninas. Revista Brasileira de Medicina Veterinária, 37(Supl.1:71-76, 2015. Laboratório de Parasitologia, Hospital Veterinário, Universidade Federal do Espírito Santo, Rua Alto Universitário, s/n, Guararema, Alegre, ES 29500-000, Brasil. E-mail: marcelle_temporim@hotmail.com Were collected 100 fecal samples from dogs from August 2014 to April 2015 from the Zoonosis Control Center (CCZ of Cachoeiro de Itapemirim-ES. These were sent to the laboratory of Parasitology of the Veterinary Hospital of UFES, and analyzed in duplicate by the techniques of Kato-Katz, Hoffman, TF-Test Modified/Dog and Willis in order to evaluate the technique that present higher sensitivity, convenience and lower expenses with materials for parasitological diagnosis. Statistical analysis was performed using Fisher’s exact test and kappa the 5% significance level. Together they showed up 68 positive samples, 31, 34, 26 and 62 for technical Kato-Katz, Hoffman, TF-Test and Willis respectively. The results showed that the use of Willis technique should be adopted as the standard for egg Ancylostoma spp., since the techniques Kato-Katz, Hoffman and TF-Test showed a low sensitivity for diagnosis of this parasite, and technic of Hoffman should be used as standard for Toxocara spp. In relation to convenience and lower expenses, Willis technique, should be preferred, because the runtime and the microscope slide reading is fast, requiring only the use of a supersaturated solution.

  14. Biomagnetic techniques for evaluating gastric emptying, peristaltic contraction and transit time.

    Science.gov (United States)

    la Roca-Chiapas, Jose María De; Cordova-Fraga, Teodoro

    2011-10-15

    Biomagnetic techniques were used to measure motility in various parts of the gastrointestinal (GI) tract, particularly a new technique for detecting magnetic markers and tracers. A coil was used to enhance the signal from a magnetic tracer in the GI tract and the signal was detected using a fluxgate magnetometer or a magnetoresistor in an unshielded room. Estimates of esophageal transit time were affected by the position of the subject. The reproducibility of estimates derived using the new biomagnetic technique was greater than 85% and it yielded estimates similar to those obtained using scintigraphy. This technique is suitable for studying the effect of emotional state on GI physiology and for measuring GI transit time. The biomagnetic technique can be used to evaluate digesta transit time in the esophagus, stomach and colon, peristaltic frequency and gastric emptying and is easy to use in the hospital setting.

  15. Science as Knowledge, Practice, and Map Making: The Challenge of Defining Metrics for Evaluating and Improving DOE-Funded Basic Experimental Science

    Energy Technology Data Exchange (ETDEWEB)

    Bodnarczuk, M.

    1993-03-01

    Industrial R&D laboratories have been surprisingly successful in developing performance objectives and metrics that convincingly show that planning, management, and improvement techniques can be value-added to the actual output of R&D organizations. In this paper, I will discuss the more difficult case of developing analogous constructs for DOE-funded non-nuclear, non-weapons basic research, or as I will refer to it - basic experimental science. Unlike most industrial R&D or the bulk of applied science performed at the National Renewable Energy Laboratory (NREL), the purpose of basic experimental science is producing new knowledge (usually published in professional journals) that has no immediate application to the first link (the R) of a planned R&D chain. Consequently, performance objectives and metrics are far more difficult to define. My claim is that if one can successfully define metrics for evaluating and improving DOE-funded basic experimental science (which is the most difficult case), then defining such constructs for DOE-funded applied science should be much less problematic. With the publication of the DOE Standard - Implementation Guide for Quality Assurance Programs for Basic and Applied Research (DOE-ER-STD-6001-92) and the development of a conceptual framework for integrating all the DOE orders, we need to move aggressively toward the threefold next phase: (1) focusing the management elements found in DOE-ER-STD-6001-92 on the main output of national laboratories - the experimental science itself; (2) developing clearer definitions of basic experimental science as practice not just knowledge; and (3) understanding the relationship between the metrics that scientists use for evaluating the performance of DOE-funded basic experimental science, the management elements of DOE-ER-STD-6001-92, and the notion of continuous improvement.

  16. 99mTc-ECD: Comparison of radiochemical purity evaluation techniques

    International Nuclear Information System (INIS)

    Dumont, A.; De Beco, V.; Ait Ben Ali, S.; Goudou-Sinha, C.; Izembart, M.; Jourdain, J.R.; Lemercier, V.; Linsker, S.; Lours, S.; Moati, F.; Pajard, D.; Piketty, M.L.; Rizzo, N.; Schlageter, M.H.; Moretti, J.L.

    1997-01-01

    The aim of this study was to validate a testing method for the radiochemical purity (RCP) of the preparations of 99m Tc - ECD that is to be reproducible and easy to realize in services of Nuclear Medicine. After a review of literature, four thin-layer chromatography techniques allowing to evidence the TcO 4 - were evaluated: no.1 - Papier Whatman 31ET / ethyl acetate; no.2 - Papier Whatman 3MM chr / ethyl acetate; no.3 - ITLC Silica gel / ethyl acetate; no.4 - Baker Flex silica gel aluminium oxide IB-F / ethyl acetate (the method proposed by the laboratory). The technique no.1 has presented a bad reproducibility, as well as percentages of RCP very different from those obtained by the other techniques. The techniques no.2 and no.3, although rapid, are characterized by lower reproducibilities in comparison with technique no.4, with, some times, peaks of undetermined nature on the radio-chromatograms no.3. So, in spite of a slower migration (10 min.) the technique no.4 has been selected from the group as the most reliable technique. For this technique, the comparison between the two modes of reading the chromatography (by means of a radio-chromatograph or by measuring the activity of the two halves of the plate by an activity-meter), has shown no significant difference in RCP. Consequently, this method (Baker Flex / ethyl acetate) may by adapted in any service of nuclear medicine, no matter of its equipment

  17. Experimental hybrid evaluation of maize, for the Colombian Atlantic coast

    International Nuclear Information System (INIS)

    Urrea, R.; Navas Arboleda, A.A.; Mejia, S.; Ospina, J.G.

    1998-01-01

    To determine the yield potential and phenotypic stability four they were evaluated hybrid experimental simple and seven commercial witness of maize in eleven towns (L), during 1995 and 1996. The used experimental design was at random of complete blocks with four repetitions with parcels of four furrows of five m of longitude, distanced 0.90 m between furrows and 0.45 among blows (49 383 plts/ha) it Differ highly significant (smaller p 0.01) they were detected among genotype (G) and for the interaction G x L in the varieties yield. The analysis of stability of Eberhart and Russell (1966) it indicated that the genotypes had similar regression values; however, a clear tendency was observed to differentiate the behavior in yield of certain materials. The hybrid one experimental there are 76 and the commercial HR 661, they showed a good stability for yield

  18. Nondestructive damage detection and evaluation technique for seismically damaged structures

    Science.gov (United States)

    Adachi, Yukio; Unjoh, Shigeki; Kondoh, Masuo; Ohsumi, Michio

    1999-02-01

    The development of quantitative damage detection and evaluation technique, and damage detection technique for invisible damages of structures are required according to the lessons from the 1995 Hyogo-ken Nanbu earthquake. In this study, two quantitative damage sensing techniques for highway bridge structures are proposed. One method is to measure the change of vibration characteristics of the bridge structure. According to the damage detection test for damaged bridge column by shaking table test, this method can successfully detect the vibration characteristic change caused by damage progress due to increment excitations. The other method is to use self-diagnosis intelligent materials. According to the reinforced concrete beam specimen test, the second method can detect the damage by rupture of intelligent sensors, such as optical fiber or carbon fiber reinforced plastic rod.

  19. An Evaluation of Pinhole Castration as an Alternative Technique for ...

    African Journals Online (AJOL)

    We evaluated pinhole castration as an alternative technique for dog population control in resource poor rural communities of Gulu, Northern Uganda. Through a campaign dubbed 'Big Fix Gulu', households in selected communities were mobilized using radio announcements, posters and school visits, to present dogs for ...

  20. An experimental evaluation of the generalizing capabilities of process discovery techniques and black-box sequence models

    NARCIS (Netherlands)

    Tax, N.; van Zelst, S.J.; Teinemaa, I.; Gulden, Jens; Reinhartz-Berger, Iris; Schmidt, Rainer; Guerreiro, Sérgio; Guédria, Wided; Bera, Palash

    2018-01-01

    A plethora of automated process discovery techniques have been developed which aim to discover a process model based on event data originating from the execution of business processes. The aim of the discovered process models is to describe the control-flow of the underlying business process. At the

  1. Experimental (Network) and Evaluated Nuclear Reaction Data at NDS

    International Nuclear Information System (INIS)

    Otsuka, N.; Semkova, V.; Simakov, S.P.; Zerkin, V.

    2011-01-01

    Dr Simakov of Nuclear Data Services Unit in the Nuclear Data Section (NDS) gave a brief overview of the data compilation and evaluation activities in the nuclear data community: experimental nuclear reaction data (EXFOR, http://www-nds.iaea.org/exfor/) and evaluated nuclear reaction data (ENDF, http://www-nds.iaea.org/endf). The International Network of Nuclear Reaction Data Centres (NRDC) coordinated by NDS includes 14 Centres in 8 Countries (China, Hungary, India, Japan, Korea, Russian, Ukraine, USA) and 2 International Organizations (NEA, IAEA). It had the first meeting of four core centres (Brookhaven, Saclay, Obninsk, Vienna) in 1966 and the EXFOR was adopted as an official data exchange format. In 2000, IAEA implemented the EXFOR database as a relational multiform database and the EXFOR is a trusted, increasing and living database with 19100 experimental works (as of September 2011) and 141600 data tables. The EXFOR provides a compilation control system for selection of articles and compilation of data and the NRDC home page provides manuals, documents and codes. The nuclear data can be retrieved by the web-retrieval system or distributed on a DVD on request. The EXFOR data play a critical role in the development of evaluated nuclear reaction data. There are several major general purpose libraries: ENDF (US), CENDL (China), JEFF (EU), JENDL (Japan) and RUSFOND (Russia). In addition, there are special libraries for particular applications: EAF (European Activation File), FENDL (Fusion Evaluated Nuclear Data Library for ITER neutronics), IBANDL (Ion Beam Analysis Nuclear Data Library for surface analysis of solids), IRDF, DXS (Dosimetry, radiation damage and gas production data) and Medical portal. Dr V. Zerkin of NDS demonstrated the data retrieval from the EXFOR database and the ENDF library.

  2. Experimental (Network) and Evaluated Nuclear Reaction Data at NDS

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, N; Semkova, V; Simakov, S P; Zerkin, V [Nuclear Data Services Unit, Nuclear Data Section, IAEA, Vienna (Austria)

    2011-11-15

    Dr Simakov of Nuclear Data Services Unit in the Nuclear Data Section (NDS) gave a brief overview of the data compilation and evaluation activities in the nuclear data community: experimental nuclear reaction data (EXFOR, http://www-nds.iaea.org/exfor/) and evaluated nuclear reaction data (ENDF, http://www-nds.iaea.org/endf). The International Network of Nuclear Reaction Data Centres (NRDC) coordinated by NDS includes 14 Centres in 8 Countries (China, Hungary, India, Japan, Korea, Russian, Ukraine, USA) and 2 International Organizations (NEA, IAEA). It had the first meeting of four core centres (Brookhaven, Saclay, Obninsk, Vienna) in 1966 and the EXFOR was adopted as an official data exchange format. In 2000, IAEA implemented the EXFOR database as a relational multiform database and the EXFOR is a trusted, increasing and living database with 19100 experimental works (as of September 2011) and 141600 data tables. The EXFOR provides a compilation control system for selection of articles and compilation of data and the NRDC home page provides manuals, documents and codes. The nuclear data can be retrieved by the web-retrieval system or distributed on a DVD on request. The EXFOR data play a critical role in the development of evaluated nuclear reaction data. There are several major general purpose libraries: ENDF (US), CENDL (China), JEFF (EU), JENDL (Japan) and RUSFOND (Russia). In addition, there are special libraries for particular applications: EAF (European Activation File), FENDL (Fusion Evaluated Nuclear Data Library for ITER neutronics), IBANDL (Ion Beam Analysis Nuclear Data Library for surface analysis of solids), IRDF, DXS (Dosimetry, radiation damage and gas production data) and Medical portal. Dr V. Zerkin of NDS demonstrated the data retrieval from the EXFOR database and the ENDF library.

  3. Corrosion behavior of boride layers evaluated by the EIS technique

    Energy Technology Data Exchange (ETDEWEB)

    Campos, I. [Instituto Politecnico Nacional. SEPI-ESIME U.P. Adolfo Lopez Mateos, Zacatenco, Mexico D.F. 07738 (Mexico)], E-mail: icampos@ipn.mx; Palomar-Pardave, M. [Universidad Autonoma Metropolitana-Azcapotzalco, Materials Department, Avenue San Pablo 180 Col. Reynosa Tamaulipas, Mexico D.F. 02200 (Mexico); Amador, A. [Tecnologico de Monterrey, Campus Ciudad de Mexico, Calle del Puente 222 Col. Ejidos de Huipulco, Mexico D.F. 14380 (Mexico); VillaVelazquez, C. [Instituto Politecnico Nacional. SEPI-ESIME U.P. Adolfo Lopez Mateos, Zacatenco, Mexico D.F. 07738 (Mexico); Hadad, J. [Tecnologico de Monterrey, Campus Ciudad de Mexico, Calle del Puente 222 Col. Ejidos de Huipulco, Mexico D.F. 14380 (Mexico)

    2007-09-30

    The corrosion behavior of boride layers at the AISI 304 steel surface is evaluated in the present study. Electrochemical impedance spectroscopy (EIS) technique was used for the evaluation of the polarization resistance at the steel surface, with the aid of AUTOLAB potentiostat. Samples were treated with boron paste thickness of 4 and 5 mm, in the range of temperatures 1123 {<=} T {<=} 1273 K and exposed time of 4 and 6 h. The electrochemical technique employed 10 mV AC with a frequency scan range from 8 kHz to 3 mHz in deaerated 0.1 M NaCl solution. Nyquist diagrams show that the highest values of corrosion resistance are present in the samples borided at the temperature of 1273 K, with treatment time of 4 h and 4 mm of boron paste thickness. The values of corrosion resistance on borided steels are compared with the porosity exhibited in the layers.

  4. Evaluated Plan Stress Of Weld In Pressure Tube Using X Ray Diffraction Technique

    International Nuclear Information System (INIS)

    Phan Trong Phuc; Nguyen Duc Thanh; Luu Anh Tuyen

    2011-01-01

    X ray diffraction is a fundamental technique measuring stress, this technique has determined crystal strain in materials, from that determined stress in materials. This paper presents study of evaluating plane stress of weld in pressure tube, using modern XRD apparatus: X Pert Pro. (author)

  5. Solar energy program evaluation: an introduction

    Energy Technology Data Exchange (ETDEWEB)

    deLeon, P.

    1979-09-01

    The Program Evaluation Methodology provides an overview of the practice and methodology of program evaluation and defines more precisely the evaluation techniques and methodologies that would be most appropriate to government organizations which are actively involved in the research, development, and commercialization of solar energy systems. Formal evaluation cannot be treated as a single methodological approach for assessing a program. There are four basic types of evaluation designs - the pre-experimental design; the quasi-experimental design based on time series; the quasi-experimental design based on comparison groups; and the true experimental design. This report is organized to first introduce the role and issues of evaluation. This is to provide a set of issues to organize the subsequent sections detailing the national solar energy programs. Then, these two themes are integrated by examining the evaluation strategies and methodologies tailored to fit the particular needs of the various individual solar energy programs. (MCW)

  6. A computer program to evaluate the experimental data in instrumental multielement neutron activation analysis

    International Nuclear Information System (INIS)

    Greim, L.; Motamedi, K.; Niedergesaess, R.

    1976-01-01

    A computer code evaluating experimental data of neutron activation analysis (NAA) for determination of atomic abundancies is described. The experimental data are, beside a probe designation, the probe weight, irradiation parameters and a Ge(Li)-pulse-height-spectrum from the activity measurement. The organisation of the necessary nuclear data, comprising all methods of activation in reactor-irradiations, is given. Furthermore the automatic evaluation of spectra, the designation of the resulting peaks to nuclei and the calculation of atomic abundancies are described. The complete evaluation of a spectrum with many lines, e.g. 100 lines of 20 nuclei, takes less than 1 minute machine-time on the TR 440 computer. (orig.) [de

  7. Microbiological evaluation of anatomical organs submitted to glycerinization and freeze-drying techniques

    Directory of Open Access Journals (Sweden)

    Marianna Justo

    2016-06-01

    Full Text Available Alternatives conservation techniques are being requested with the proposal of formaldehyde substitution. Formaldehyde results in excessive anatomical specimens' weight and it can cause serious health problems to the manipulator, such as cancer. However, it provides an efficient germicide and fungicide action depending on concentration. The substitute techniques are glicerinization and freeze-drying which have advantages such as non-production of smells, lightness of the organs and dispenses the use of fixatives in conservation. As well as both intrinsic and extrinsic factors interfere in microbial growth, microbiological analyzes are essential to detect possible deteriorative microorganisms in organs and concluding effectively the technique used. Formalinized, glycerinated and freeze-drying organs were collected in three different times which were intercalated by two months, except formalinization that had one evaluation. The procedure required the use of sterilized swabs wetted in peptone water and molds measuring 5,0 cm x 10,0 cm positioned on two different piece's local resulting in 100 cm2 of area, to spread plate of total moulds, mesophiles (except in freeze-drying, psychrophilic (only in freeze-drying and Pseudomonas sp (except in formalinization. All the plates were counted and compared between each technique's evaluations by variance analyzes. Both alternatives techniques resulted in zero or in very low microbial quantity to cause health problems as well as it preserve pieces morphology. All values of all analyzes resulted below 1/ml, showing that glicerinization and freeze-drying techniques are so as efficient as formaldehyde. Keywords: Organs conservation, Anatomical techniques, Microbiology, Microbial growth

  8. Evaluation of a new image compression technique

    International Nuclear Information System (INIS)

    Algra, P.R.; Kroon, H.M.; Noordveld, R.B.; DeValk, J.P.J.; Seeley, G.W.; Westerink, P.H.

    1988-01-01

    The authors present the evaluation of a new image compression technique, subband coding using vector quantization, on 44 CT examinations of the upper abdomen. Three independent radiologists reviewed the original images and compressed versions. The compression ratios used were 16:1 and 20:1. Receiver operating characteristic analysis showed no difference in the diagnostic contents between originals and their compressed versions. Subjective visibility of anatomic structures was equal. Except for a few 20:1 compressed images, the observers could not distinguish compressed versions from original images. They conclude that subband coding using vector quantization is a valuable method for data compression in CT scans of the abdomen

  9. {sup 99m}Tc-ECD: Comparison of radiochemical purity evaluation techniques; {sup 99m}Tc-ECD: Comparaison de techniques d`evaluation de la purete radiochimique

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, A.; De Beco, V.; Ait Ben Ali, S.; Goudou-Sinha, C.; Izembart, M.; Jourdain, J.R.; Lemercier, V.; Linsker, S.; Lours, S.; Moati, F.; Pajard, D.; Piketty, M.L.; Rizzo, N.; Schlageter, M.H.; Moretti, J.L. [Groupe de travail `Radiopharmaceutiques - Ile de France` (France)

    1997-12-31

    The aim of this study was to validate a testing method for the radiochemical purity (RCP) of the preparations of {sup 99m}Tc - ECD that is to be reproducible and easy to realize in services of Nuclear Medicine. After a review of literature, four thin-layer chromatography techniques allowing to evidence the TcO{sub 4}{sup -} were evaluated: no.1 - Papier Whatman 31ET / ethyl acetate; no.2 - Papier Whatman 3MM chr / ethyl acetate; no.3 - ITLC Silica gel / ethyl acetate; no.4 - Baker Flex silica gel aluminium oxide IB-F / ethyl acetate (the method proposed by the laboratory). The technique no.1 has presented a bad reproducibility, as well as percentages of RCP very different from those obtained by the other techniques. The techniques no.2 and no.3, although rapid, are characterized by lower reproducibilities in comparison with technique no.4, with, some times, peaks of undetermined nature on the radio-chromatograms no.3. So, in spite of a slower migration (10 min.) the technique no.4 has been selected from the group as the most reliable technique. For this technique, the comparison between the two modes of reading the chromatography (by means of a radio-chromatograph or by measuring the activity of the two halves of the plate by an activity-meter), has shown no significant difference in RCP. Consequently, this method (Baker Flex / ethyl acetate) may by adapted in any service of nuclear medicine, no matter of its equipment

  10. Speech evaluation and dental arch shape following pushback palatoplasty in cleft palate patients: Supraperiosteal flap technique versus mucoperiosteal flap technique.

    Science.gov (United States)

    Ito, Shizuyo; Noguchi, Makoto; Suda, Yoshiyuki; Yamaguchi, Akira; Kohama, Geniku; Yamamoto, Etsuhide

    2006-04-01

    The aim of this study was to evaluate and compare the maxillary dental arch shape and speech of cleft palate patients following pushback palatoplasty using either the supraperiosteal flap technique or the mucoperiosteal flap technique. Sixty-two patients (29, cleft palate only; 33, unilateral cleft lip, alveolus and palate) operated on by the supraperiosteal technique and 47 patients (23, cleft palate only; 24 unilateral cleft lip, alveolus and palate) by the mucoperiosteal technique were reviewed in this study. Dental arch shape and speech proficiency at preschool and school age were evaluated in all patients. Dental arch shapes were classified as U type (good dental arch shape) and V type (narrow dental arch shape). In cleft palate only patients, U type was observed in 90% of the supraperiosteal group and 83% of the mucoperiosteal group. In unilateral cleft lip, alveolus and palate patients, U type was observed in 85% of the supraperiosteal group, while only in 33% of the mucoperiosteal group. In cleft palate only patients, normal speech at school age was observed 100% of the supraperiosteal group and 83% of the mucoperiosteal group. In unilateral cleft lip, alveolus and palate patients, normal speech at school age was observed in 97% of the supraperiosteal group and 75% of the mucoperiosteal group. Misarticulation was frequently found in patients with the V type of dental arch shape. It is suggested that pushback palatoplasty using the supraperiosteal technique is more advantageous for speech development compared with the mucoperiosteal technique.

  11. Evaluation of various filling techniques in distal canals of mandibular ...

    African Journals Online (AJOL)

    Evaluation of various filling techniques in distal canals of mandibular molars instrumented with different single-file nickel-titanium systems. ... Comparisons between groups were applied using Student's t-test or one-way ANOVA for normally distributed data. The Mann-Whitney U-test or Kruskal-Wallis test was used when ...

  12. A Small Crack Length Evaluation Technique by Electronic Scanning

    International Nuclear Information System (INIS)

    Cho, Yong Sang; Kim, Jae Hoon

    2009-01-01

    The results of crack evaluation by conventional UT(Ultrasonic Test)is highly depend on the inspector's experience or knowledge of ultrasound. Phased array UT system and its application methods for small crack length evaluation will be a good alternative method which overcome present UT weakness. This study was aimed at checking the accuracy of crack length evaluation method by electronic scanning and discuss about characteristics of electronic scanning for crack length evaluation. Especially ultrasonic phased array with electronic scan technique was used in carrying out both sizing and detect ability of crack as its length changes. The response of ultrasonic phased array was analyzed to obtain the special method of determining crack length without moving the transducer and detectability of crack minimal length and depth from the material. A method of crack length determining by electronic scanning for the small crack is very real method which has it's accuracy and verify the effectiveness of method compared to a conventional crack length determination

  13. A general technique for confluence of calculational and experimental information with application to power distribution determination

    International Nuclear Information System (INIS)

    Serov, I.V.; Hoogenboom, J.E.

    1994-01-01

    Physical quantities can be obtained by utilizing different informational sources. The available information is usually associated with systematic and statistical errors. If the informational sources are utilized simultaneously, then it is possible to obtain posterior estimates of the quantities with better statistical properties than exhibited by any prior estimates. The general technique for confluence of any number possibly dependent informational sources can be developed. Insight into the nature of the informational source allows different types of data associated with the source to be improved. The formulas of the technique are presented and applied to the power distribution determination for research reactor HOR of the Delft University of Technology, employing calculational and experimental data. (authors). 5 refs., 1 tab., 5 figs

  14. Constructing experimental designs for discrete-choice experiments: report of the ISPOR Conjoint Analysis Experimental Design Good Research Practices Task Force.

    Science.gov (United States)

    Reed Johnson, F; Lancsar, Emily; Marshall, Deborah; Kilambi, Vikram; Mühlbacher, Axel; Regier, Dean A; Bresnahan, Brian W; Kanninen, Barbara; Bridges, John F P

    2013-01-01

    Stated-preference methods are a class of evaluation techniques for studying the preferences of patients and other stakeholders. While these methods span a variety of techniques, conjoint-analysis methods-and particularly discrete-choice experiments (DCEs)-have become the most frequently applied approach in health care in recent years. Experimental design is an important stage in the development of such methods, but establishing a consensus on standards is hampered by lack of understanding of available techniques and software. This report builds on the previous ISPOR Conjoint Analysis Task Force Report: Conjoint Analysis Applications in Health-A Checklist: A Report of the ISPOR Good Research Practices for Conjoint Analysis Task Force. This report aims to assist researchers specifically in evaluating alternative approaches to experimental design, a difficult and important element of successful DCEs. While this report does not endorse any specific approach, it does provide a guide for choosing an approach that is appropriate for a particular study. In particular, it provides an overview of the role of experimental designs for the successful implementation of the DCE approach in health care studies, and it provides researchers with an introduction to constructing experimental designs on the basis of study objectives and the statistical model researchers have selected for the study. The report outlines the theoretical requirements for designs that identify choice-model preference parameters and summarizes and compares a number of available approaches for constructing experimental designs. The task-force leadership group met via bimonthly teleconferences and in person at ISPOR meetings in the United States and Europe. An international group of experimental-design experts was consulted during this process to discuss existing approaches for experimental design and to review the task force's draft reports. In addition, ISPOR members contributed to developing a consensus

  15. Evaluation of syngas production unit cost of bio-gasification facility using regression analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Yangyang; Parajuli, Prem B.

    2011-08-10

    Evaluation of economic feasibility of a bio-gasification facility needs understanding of its unit cost under different production capacities. The objective of this study was to evaluate the unit cost of syngas production at capacities from 60 through 1800Nm 3/h using an economic model with three regression analysis techniques (simple regression, reciprocal regression, and log-log regression). The preliminary result of this study showed that reciprocal regression analysis technique had the best fit curve between per unit cost and production capacity, with sum of error squares (SES) lower than 0.001 and coefficient of determination of (R 2) 0.996. The regression analysis techniques determined the minimum unit cost of syngas production for micro-scale bio-gasification facilities of $0.052/Nm 3, under the capacity of 2,880 Nm 3/h. The results of this study suggest that to reduce cost, facilities should run at a high production capacity. In addition, the contribution of this technique could be the new categorical criterion to evaluate micro-scale bio-gasification facility from the perspective of economic analysis.

  16. Progress in thin film techniques

    International Nuclear Information System (INIS)

    Weingarten, W.

    1996-01-01

    Progress since the last Workshop is reported on superconducting accelerating RF cavities coated with thin films. The materials investigated are Nb, Nb 3 Sn, NbN and NbTiN, the techniques applied are diffusion from the vapour phase (Nb 3 Sn, NbN), the bronze process (Nb 3 Sn), and sputter deposition on a copper substrate (Nb, NbTiN). Specially designed cavities for sample evaluation by RF methods have been developed (triaxial cavity). New experimental techniques to assess the RF amplitude dependence of the surface resistance are presented (with emphasis on niobium films sputter deposited on copper). Evidence is increasing that they are caused by magnetic flux penetration into the surface layer. (R.P.)

  17. Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality

    International Nuclear Information System (INIS)

    Park, Ik Gun

    1994-01-01

    This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to 10μm extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques

  18. Performance Evaluation Of Furrow Lengths And Field Application Techniques

    Directory of Open Access Journals (Sweden)

    Issaka

    2015-08-01

    Full Text Available Abstract The study evaluated performance of furrow lengths and field application techniques. The experiment was conducted on 2000 m2 field at Bontanga irrigation scheme. Randomized Complete Block Design RCBD was used with three replicates. The replicates include Blocks A B and C of furrow lengths 100 m 75 m and 50 m respectively. Each replicate had surge cut-off cut-back and bunds treatments. Water was introduced into the furrows and the advance distances and time were measured. Results of the study showed that at Block A surge technique recorded the highest advance rate of 1.26 minm and opportunity time of 11 min whilst bunds recorded the lowest advance rate of 0.92 minm. Significant difference 3.32 pamp88050.05 occurred between treatment means of field application techniques at Block A 100 m. Significant difference 2.71 pamp88050.05 was also recorded between treatment means. At Block B 75 m there was significant difference 2.71 pamp88050.05 between treatment means. No significant difference 0.14 pamp88040.05 was observed among surge cut-back and bunds techniques. There was significant difference 2.60 pamp88050.05 between treatment means but no significant difference between cut-back and bunds techniques in Block C 50 m. Their performance was ranked in the order Surge Cut-back Cut-off Bunds for furrow lengths 100 m 75 m and 50 m respectively.

  19. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

    Directory of Open Access Journals (Sweden)

    Emi Kamimura

    Full Text Available The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D images of teeth captured by a digital impression technique to a conventional impression technique in vivo.Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE. A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE. Stereolithography (STL data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D laboratory scanner (D810, 3shape. The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test.The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm than when using a conventional impression technique (0.023 ± 0.01 mm.The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator.

  20. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques

    Science.gov (United States)

    Kamimura, Emi; Tanaka, Shinpei; Takaba, Masayuki; Tachi, Keita; Baba, Kazuyoshi

    2017-01-01

    Purpose The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D) images of teeth captured by a digital impression technique to a conventional impression technique in vivo. Materials and methods Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE). A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE). Stereolithography (STL) data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D) laboratory scanner (D810, 3shape). The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software) for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test). Results The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm) than when using a conventional impression technique (0.023 ± 0.01 mm). Conclusion The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator. PMID:28636642

  1. The techniques of quality operations computational and experimental researches of the launch vehicles in the drawing-board stage

    Science.gov (United States)

    Rozhaeva, K.

    2018-01-01

    The aim of the researchis the quality operations of the design process at the stage of research works on the development of active on-Board system of the launch vehicles spent stages descent with liquid propellant rocket engines by simulating the gasification process of undeveloped residues of fuel in the tanks. The design techniques of the gasification process of liquid rocket propellant components residues in the tank to the expense of finding and fixing errors in the algorithm calculation to increase the accuracy of calculation results is proposed. Experimental modelling of the model liquid evaporation in a limited reservoir of the experimental stand, allowing due to the false measurements rejection based on given criteria and detected faults to enhance the results reliability of the experimental studies; to reduce the experiments cost.

  2. Phase-mapping technique for the evaluation of aortic valve stenosis by MR

    International Nuclear Information System (INIS)

    Engels, G.; Mueller, E.; Reynen, K.; Wilke, N.; Bachmann, K.

    1992-01-01

    New MR-techniques for quantitative blood flow registration such as phase-mapping (a two-dimensional space-resolved technique with a time-averaged measurement of blood flow) or RACE (real-time acquisition and evaluation of blood flow in one-dimensional space projection) are available for the diagnosis of valvular heart disease. Initial results of grading aortic valve stenosis by these methods are shown in comparison to continuous wave Ultrasound-Doppler. Two groups of 15 patients were examined by RACE or phase-mapping, 12 respectively 8 of whom suffered from an aortic valve stenosis. The shape of blood flow profiles as well as grading of aortic valve stenosis show high concordance when comparing the results of MR and Doppler technique. Good reliability and practicability of the demonstrated MR-method are shown. With respect to the results of RACE and phase-mapping the development of an alternative and competing MR-method for the evaluation of valvular heart disease and shunt diagnostics seems possible. (orig.)

  3. Phase-mapping technique for the evaluation of aortic valve stenosis by MR

    Energy Technology Data Exchange (ETDEWEB)

    Engels, G. [Medizinische Klinik 2, Univ. of Erlangen (Germany); Mueller, E. [Siemens Medical Engineering Group, Erlangen (Germany); Reynen, K. [Medizinische Klinik 2, Univ. of Erlangen (Germany); Wilke, N. [Siemens Medical Engineering Group, Erlangen (Germany); Bachmann, K. [Medizinische Klinik 2, Univ. of Erlangen (Germany)

    1992-08-01

    New MR-techniques for quantitative blood flow registration such as phase-mapping (a two-dimensional space-resolved technique with a time-averaged measurement of blood flow) or RACE (real-time acquisition and evaluation of blood flow in one-dimensional space projection) are available for the diagnosis of valvular heart disease. Initial results of grading aortic valve stenosis by these methods are shown in comparison to continuous wave Ultrasound-Doppler. Two groups of 15 patients were examined by RACE or phase-mapping, 12 respectively 8 of whom suffered from an aortic valve stenosis. The shape of blood flow profiles as well as grading of aortic valve stenosis show high concordance when comparing the results of MR and Doppler technique. Good reliability and practicability of the demonstrated MR-method are shown. With respect to the results of RACE and phase-mapping the development of an alternative and competing MR-method for the evaluation of valvular heart disease and shunt diagnostics seems possible. (orig.)

  4. Comparison of QuadrapolarTM radiofrequency lesions produced by standard versus modified technique: an experimental model

    Directory of Open Access Journals (Sweden)

    Safakish R

    2017-06-01

    Full Text Available Ramin Safakish Allevio Pain Management Clinic, Toronto, ON, Canada Abstract: Lower back pain (LBP is a global public health issue and is associated with substantial financial costs and loss of quality of life. Over the years, different literature has provided different statistics regarding the causes of the back pain. The following statistic is the closest estimation regarding our patient population. The sacroiliac (SI joint pain is responsible for LBP in 18%–30% of individuals with LBP. Quadrapolar™ radiofrequency ablation, which involves ablation of the nerves of the SI joint using heat, is a commonly used treatment for SI joint pain. However, the standard Quadrapolar radiofrequency procedure is not always effective at ablating all the sensory nerves that cause the pain in the SI joint. One of the major limitations of the standard Quadrapolar radiofrequency procedure is that it produces small lesions of ~4 mm in diameter. Smaller lesions increase the likelihood of failure to ablate all nociceptive input. In this study, we compare the standard Quadrapolar radiofrequency ablation technique to a modified Quadrapolar ablation technique that has produced improved patient outcomes in our clinic. The methodology of the two techniques are compared. In addition, we compare results from an experimental model comparing the lesion sizes produced by the two techniques. Taken together, the findings from this study suggest that the modified Quadrapolar technique provides longer lasting relief for the back pain that is caused by SI joint dysfunction. A randomized controlled clinical trial is the next step required to quantify the difference in symptom relief and quality of life produced by the two techniques. Keywords: lower back pain, radiofrequency ablation, sacroiliac joint, Quadrapolar radiofrequency ablation

  5. Modelling concentration-analgesia relationships for morphine to evaluate experimental pain models

    DEFF Research Database (Denmark)

    Sverrisdóttir, Eva; Foster, David John Richard; Upton, Richard Neil

    2015-01-01

    The aim of this study was to develop population pharmacokinetic-pharmacodynamic models for morphine in experimental pain induced by skin heat and muscle pressure, and to evaluate the experimental pain models with regard to assessment of morphine pharmacodynamics. In a randomized, double......-blind, placebo-controlled, crossover study, 39 healthy volunteers received an oral dose of 30 mg morphine hydrochloride or placebo. Non-linear mixed effects modelling was used to describe the plasma concentrations of morphine and metabolites, and the analgesic effect of morphine on experimental pain in skin...... and muscle. Baseline pain metrics varied between individuals and occasions, and were described with interindividual and interoccasion variability. Placebo-response did not change with time. For both pain metrics, morphine effect was proportional to baseline pain and was described with a linear model...

  6. An experimental study of soil temperature regimes associated with solar disinfestation techniques under greenhouse conditions in Greece.

    Science.gov (United States)

    Garofalakis, I; Tsiros, I; Frangoudakis, A; Chronopoulos, K; Flouri, F

    2006-01-01

    This paper deals with an experimental study of various techniques that have been applied for soil disinfestation purposes under greenhouse conditions. Various meteorological parameters and soil temperatures were measured for four different experimental soil segments (three associated with different disinfestation techniques and one as a reference) at depths varying between 0-1 m and with a time interval of 5 min in a greenhouse located in the Agricultural University of Athens Campus, Greece. Results showed that plastic polyethylene films such as covers, metallic conductors or a combination of both were able to enhance heat transfer and temperature increase in greenhouse soil. For typical disinfestation conditions, the depth-averaged temperature values for plastic covers, metallic conductors, and the combination of both were found to be higher than those for the reference of about 5 degrees C, 12 degrees C and 15 micro C, respectively. Moreover, the remained population percentages 50 days after the initiation of the experiment were found to be 19.3%, 25.3%, 37.3% Kcat 94% of the initial population, for the combination of metallic conductors and plastic covers, metallic conductors, plastic cover, and for the reference, respectively.

  7. In-place cement stabilized base reconstruction techniques interim report : "construction and two year evaluation".

    Science.gov (United States)

    2002-08-01

    The purpose of this research was to evaluate the effectiveness of soil cement shrinkage crack mitigation techniques. The contents of this report reflect an evaluation of the construction of the test sections and a two-year evaluation of the test sect...

  8. Experimentation and evaluation of advanced integrated system concepts

    Science.gov (United States)

    Ross, M.; Garrigus, K.; Gottschalck, J.; Rinearson, L.; Longee, E.

    1980-09-01

    This final report examines the implementation of a time-phased test bed for experimentation and evaluation of advanced system concepts relative to the future Defense Switched Network (DSN). After identifying issues pertinent to the DSN, a set of experiments which address these issues are developed. Experiments are ordered based on their immediacy and relative importance to DSN development. The set of experiments thus defined allows requirements for a time phased implementation of a test bed to be identified, and several generic test bed architectures which meet these requirements are examined. Specific architecture implementations are costed and cost/schedule profiles are generated as a function of experimental capability. The final recommended system consists of two separate test beds: a circuit switch test bed, configured around an off-the-shelf commercial switch, and directed toward the examination of nearer term and transitional issues raised by the evolving DSN; and a packet/hybrid test bed, featuring a discrete buildup of new hardware and software modules, and directed toward examination of the more advanced integrated voice and data telecommunications issues and concepts.

  9. Experimental validation of incomplete data CT image reconstruction techniques

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Hsiao, M.L.; Tam, K.C.

    1989-01-01

    X-ray CT inspection of large metal parts is often limited by x-ray penetration problems along many of the ray paths required for a complete CT data set. In addition, because of the complex geometry of many industrial parts, manipulation difficulties often prevent scanning over some range of angles. CT images reconstructed from these incomplete data sets contain a variety of artifacts which limit their usefulness in part quality determination. Over the past several years, the authors' company has developed 2 new methods of incorporating a priori information about the parts under inspection to significantly improve incomplete data CT image quality. This work reviews the methods which were developed and presents experimental results which confirm the effectiveness of the techniques. The new methods for dealing with incomplete CT data sets rely on a priori information from part blueprints (in electronic form), outer boundary information from touch sensors, estimates of part outer boundaries from available x-ray data, and linear x-ray attenuation coefficients of the part. The two methods make use of this information in different fashions. The relative performance of the two methods in detecting various flaw types is compared. Methods for accurately registering a priori information with x-ray data are also described. These results are critical to a new industrial x-ray inspection cell built for inspection of large aircraft engine parts

  10. Functional imaging of the pancreas. Image processing techniques and clinical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Fumiko

    1984-02-01

    An image processing technique for functional imaging of the pancreas was developed and is here reported. In this paper, clinical efficacy of the technique for detecting pancreatic abnormality is evaluated in comparison with conventional pancreatic scintigraphy and CT. For quantitative evaluation, functional rate, i.e. the rate of normal functioning pancreatic area, was calculated from the functional image and subtraction image. Two hundred and ninety-five cases were studied using this technique. Conventional image had a sensitivity of 65% and a specificity of 78%, while the use of functional imaging improved sensitivity to 88% and specificity to 88%. The mean functional rate in patients with pancreatic disease was significantly lower (33.3 +- 24.5 in patients with chronic pancreatitis, 28.1 +- 26.9 in patients with acute pancreatitis, 43.4 +- 22.3 in patients with diabetes mellitus, 20.4 +- 23.4 in patients with pancreatic cancer) than the mean functional rate in cases without pancreatic disease (86.4 +- 14.2). It is suggested that functional image of the pancreas reflecting pancreatic exocrine function and functional rate is a useful indicator of pancreatic exocrine function.

  11. Evaluation of an advanced physical diagnosis course using consumer preferences methods: the nominal group technique.

    Science.gov (United States)

    Coker, Joshua; Castiglioni, Analia; Kraemer, Ryan R; Massie, F Stanford; Morris, Jason L; Rodriguez, Martin; Russell, Stephen W; Shaneyfelt, Terrance; Willett, Lisa L; Estrada, Carlos A

    2014-03-01

    Current evaluation tools of medical school courses are limited by the scope of questions asked and may not fully engage the student to think on areas to improve. The authors sought to explore whether a technique to study consumer preferences would elicit specific and prioritized information for course evaluation from medical students. Using the nominal group technique (4 sessions), 12 senior medical students prioritized and weighed expectations and topics learned in a 100-hour advanced physical diagnosis course (4-week course; February 2012). Students weighted their top 3 responses (top = 3, middle = 2 and bottom = 1). Before the course, 12 students identified 23 topics they expected to learn; the top 3 were review sensitivity/specificity and high-yield techniques (percentage of total weight, 18.5%), improving diagnosis (13.8%) and reinforce usual and less well-known techniques (13.8%). After the course, students generated 22 topics learned; the top 3 were practice and reinforce advanced maneuvers (25.4%), gaining confidence (22.5%) and learn the evidence (16.9%). The authors observed no differences in the priority of responses before and after the course (P = 0.07). In a physical diagnosis course, medical students elicited specific and prioritized information using the nominal group technique. The course met student expectations regarding education of the evidence-based physical examination, building skills and confidence on the proper techniques and maneuvers and experiential learning. The novel use for curriculum evaluation may be used to evaluate other courses-especially comprehensive and multicomponent courses.

  12. An Evaluation of the Acoustic Signal processing Techniques for Sodium-Water Reaction Detection in KALIMER-600

    International Nuclear Information System (INIS)

    Hur, Seop; Seong, S. H.; Kim, T. J.; Kim, S. O.; Lee, M. K.

    2005-02-01

    KALIMER-600 is a pool type fast breeder reactor using liquid sodium as a coolant. Although it has the several advantages such as long-term fuel cycle and enhanced safety concepts, it is possible to leak the secondary side water/steam into sodium boundary. This event could make the plant abnormal condition. One of the major design issues in KALIMER-600 is, therefore, to develop the system which can early detect the sodium-water reaction to protect the sodium-water reaction event. After evaluating the various signal processing techniques for passive acoustic leak detection, we have proposed the early leak detection logics. the signal processing techniques for evaluation were the spectral estimation using the linear modeling, the estimation error of linear modeling, the system adaptation rate using an adaptive signal processing, and the background noise cancellation using adaptive and fixed filtering. As the analysis results regarding the stationary and the cross-correlation of leak signals and background noises, the two signal systems met a wide-dense stationary process and there was only the week cross correlation relationship between two signals. It is ,therefore, possible to use the linear/harmonic modeling of signal systems, and the leak signal in sensor outputs can be discriminated. As the results of the evaluation of the various spectral estimation methods, the spectral estimation method based on autoregressive modeling was more practical comparing with other methods in the sodium-water reaction detection. The passive acoustic leak detection logics were suggested based on above evaluations. the logics consist of 3 levels; transient identification, leak determination and leak symptom identification. The simulation results using sodium-water reaction signals showed that it was possible to determine the leak at above -3dB of SNR, while between -3 dB and -10 dB of SNR the logics determined the leak symptom identification. The detection sensitivity can be enhanced

  13. Experimental evaluation of coating delamination in vinyl coated metal forming

    International Nuclear Information System (INIS)

    Son, Young Ki; Lee, Chan Joo; Kim, Byung Min; Lee, Jung Min; Byoen, Sang Doek; Lee, Soen Bong

    2012-01-01

    In this paper, a new evaluation and prediction method for coating delamination during sheet metal forming is presented. On the basis of the forming limit diagram (FLD), the current study evaluates the delamination of PET coating by using a cross cut specimen, dome test, and rectangular cup drawing test. Dome test specimens were subjected to biaxial, plane strain, and uniaxial deformation modes. Rectangular cup drawing test specimens were subjected to the deep drawing deformation mode, and compression deformation mode. A vinyl coated metal (VCM) sheet consists of three layers of polymer on the sheet metals: a protective film, a PET layer and a PVC layer. The areas with coating delamination were identified, and the results of the evaluation were plotted according to major and minor strain values, depicting coating delamination. The constructed delamination limit diagram (DLD) can be used to determine the forming limit of VCM during the complex press forming process. ARGUS (GOM) was employed to identify the strain value and deformation mode of the delaminated surface after the press forming. After identifying the areas of delamination, the DLD of the PET coating can be constructed in a format similar to that of the FLD. The forming limit of the VCM sheet can be evaluated using the superimposition of the delamination limit strain of the coating onto the FLD of VCM sheet. The experimental results showed that the proposed test method will support the sheet metal forming process design for VCM sheets. The assessment method presented in this study can be used to determine the delamination limit strain under plastic deformation of other polymer coated metals. The experimental results suggested that the proposed testing method is effective in evaluating delamination for specific applications

  14. Experimental evaluation of coating delamination in vinyl coated metal forming

    Energy Technology Data Exchange (ETDEWEB)

    Son, Young Ki; Lee, Chan Joo; Kim, Byung Min [Pusan National Univ., Busan (Korea, Republic of); Lee, Jung Min [Korea Institute of Industrial Technology, Busan (Korea, Republic of); Byoen, Sang Doek [HA Digital Engineering Gr., Seongsan Gu (Korea, Republic of); Lee, Soen Bong [Keimyung Univ., Daegu (Korea, Republic of)

    2012-10-15

    In this paper, a new evaluation and prediction method for coating delamination during sheet metal forming is presented. On the basis of the forming limit diagram (FLD), the current study evaluates the delamination of PET coating by using a cross cut specimen, dome test, and rectangular cup drawing test. Dome test specimens were subjected to biaxial, plane strain, and uniaxial deformation modes. Rectangular cup drawing test specimens were subjected to the deep drawing deformation mode, and compression deformation mode. A vinyl coated metal (VCM) sheet consists of three layers of polymer on the sheet metals: a protective film, a PET layer and a PVC layer. The areas with coating delamination were identified, and the results of the evaluation were plotted according to major and minor strain values, depicting coating delamination. The constructed delamination limit diagram (DLD) can be used to determine the forming limit of VCM during the complex press forming process. ARGUS (GOM) was employed to identify the strain value and deformation mode of the delaminated surface after the press forming. After identifying the areas of delamination, the DLD of the PET coating can be constructed in a format similar to that of the FLD. The forming limit of the VCM sheet can be evaluated using the superimposition of the delamination limit strain of the coating onto the FLD of VCM sheet. The experimental results showed that the proposed test method will support the sheet metal forming process design for VCM sheets. The assessment method presented in this study can be used to determine the delamination limit strain under plastic deformation of other polymer coated metals. The experimental results suggested that the proposed testing method is effective in evaluating delamination for specific applications.

  15. Preliminary Experimental Results on the Technique of Artificial River Replenishment to Mitigate Sediment Loss Downstream Dams

    Science.gov (United States)

    Franca, M. J.; Battisacco, E.; Schleiss, A. J.

    2014-12-01

    The transport of sediments by water throughout the river basins, from the steep slopes of the upstream regions to the sea level, is recognizable important to keep the natural conditions of rivers with a role on their ecology processes. Over the last decades, a reduction on the supply of sand and gravel has been observed downstream dams existing in several alpine rivers. Many studies highlight that the presence of a dam strongly modifies the river behavior in the downstream reach, in terms of morphology and hydrodynamics, with consequences on local ecology. Sediment deficit, bed armoring, river incision and bank instability are the main effects which affect negatively the aquatic habitats and the water quality. One of the proposed techniques to solve the problem of sediment deficit downstream dams, already adopted in few Japanese and German rivers although on an unsatisfactory fashion, is the artificial replenishment of these. Generally, it was verified that the erosion of the replenishments was not satisfactory and the transport rate was not enough to move the sediments to sufficient downstream distances. In order to improve and to provide an engineering answer to make this technique more applicable, a series of laboratory tests are ran as preparatory study to understand the hydrodynamics of the river flow when the replenishment technique is applied. Erodible volumes, with different lengths and submergence conditions, reproducing sediment replenishments volumes, are positioned along a channel bank. Different geometrical combinations of erodible sediment volumes are tested as well on the experimental flume. The first results of the experimental research, concerning erosion time evolution, the influence of discharge and the distance travelled by the eroded sediments, will be presented and discussed.

  16. X-ray spectroscopy: An experimental technique to measure charge state distribution during ion–solid interaction

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Prashant, E-mail: prashant@iuac.res.in; Nandi, Tapan

    2016-01-08

    Charge state distributions of {sup 56}Fe and {sup 58}Ni projectile ions passing through thin carbon foils have been studied in the energy range of 1.65–2.69 MeV/u using a novel method involving the X-ray spectroscopy technique. Interestingly the charge state distribution in the bulk shows Lorentzian behavior instead of usual Gaussian distribution. Further, different parameters of charge state distribution like mean charge state, distribution width and asymmetric parameter are determined and compared with the empirical calculations and ETACHA predictions. It is found that the X-ray measurement technique is appropriate to determine the mean charge state during the ion–solid interaction or in the bulk. Interestingly, empirical formalism predicts much lower mean charge states of the projectile ions compared to X-ray measurements which clearly indicate multi-electron capture from the target surface. The ETACHA predictions and experimental results are found to be comparable for the present energy regime. - Highlights: • New method is proposed to determine charge state distribution using X-ray technique. • Charge state distribution parameters are calculated and compared with various theoretical predictions. • X-ray technique is found to be appropriate to segregate the charge state distribution in the bulk from the target surface. • ETACHA predictions are found satisfactory in the energy range of ≥1.65 MeV/u.

  17. Experimental Facilities for Performance Evaluation of Fast Reactor Components

    International Nuclear Information System (INIS)

    Chandramouli, S.; Kumar, V.A. Suresh; Shanmugavel, M.; Vijayakumar, G.; Vinod, V.; Noushad, I.B.; Babu, B.; Kumar, G. Padma; Nashine, B.K.; Rajan, K.K.

    2013-01-01

    Brief details about various experimental facilities catering to the testing and performance evaluation requirements of fast reactor components have been brought out. These facilities have been found to be immensely useful to continue research and development activities in the areas of component development and testing, sodium technology, thermal hydraulics and sodium instrumentation for the SFR’s. In addition new facilities which have been planned will be of great importance for the developmental activities related to future SFR’s

  18. Evaluation of missing data techniques for in-car automatic speech recognition

    OpenAIRE

    Wang, Y.; Vuerinckx, R.; Gemmeke, J.F.; Cranen, B.; Hamme, H. Van

    2009-01-01

    Wang Y., Vuerinckx R., Gemmeke J., Cranen B., Van hamme H., ''Evaluation of missing data techniques for in-car automatic speech recognition'', Proceedings NAG/DAGA 2009 - international conference on acoustics, 4 pp., March 23-26, 2009, Rotterdam, The Netherlands.

  19. Nondestructive technique application for corrosion evaluation by hydrogen charging of stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Kyung, E-mail: leejink@deu.ac.kr [Department of Mechanical Engineering, Dongeui University, Busan (Korea, Republic of); Bae, Dong Su [Department of Advanced Materials Engineering, Dongeui University, Busan (Korea, Republic of); Lee, Sang Pill; Hwang, Sung Guk [Department of Mechanical Engineering, Dongeui University, Busan (Korea, Republic of); Lee, Joon Hyun [School of Mechanical Engineering, Pusan National University, Busan (Korea, Republic of)

    2016-11-01

    Highlights: • We have studied on the nondestructive technique application for corrosion evaluation by hydrogen charging of stainless steel. An ultrasonic test (UT) is an useful method to evaluate the mechanical properties of material. By measuring the velocity and the attenuation of ultrasonic wave propagating the hydrogen charged stainless steel, the relation of ultrasonic wave and mechanical properties of hydrogen charged 316L stainless steel was discussed. However, in order to evaluate the dynamic behavior of materials, an acoustic emission (AE) technique was applied to investigate the corrosion characteristics of hydrogen charged specimen. Acoustic emission is one of elastic waves caused by dislocation, cracks initiation and propagation within material from loading outside. The waveform of the acoustic emission is different depending on the damage mechanism of material. Lots of AE parameters such as energy, duration time, event and amplitude were used to analyze the dynamic behavior of the hydrogen charged specimen. • A conventional 316L stainless steel was used in this study, and electrochemical treat system for hydrogen charging of the specimen. ASTM (G142) type tensile specimens (diameter 6.0 mm, gage length 28.6 mm) were prepared, and sulfuric acid(H{sub 2}SO{sub 4}) and arsenic trioxide(As{sub 2}O{sub 3}) were used as the electrolyte, and potentiostat(HA 151) supplied the current to platinum wire and specimen. • Tensile strength and attenuation coefficient has a relation to some extent. Therefore, we could estimate the tensile strength and the hydrogen charging time by measuring the attenuation coefficient using ultrasonic wave nondestructively. • Acoustic emission technique was useful to evaluate the dynamic damage because AE parameters of AE event, average energy and average frequency showed various change by external loading at the specimens with and without hydrogen. - Abstract: Caused corrosion by hydrogen on stainless steel using

  20. The fate of neurotization techniques on reinnervation after denervation of the gastrocnemius muscle: an experimental study.

    Science.gov (United States)

    Askar, I; Sabuncuoglu, B T; Yormuk, E; Saray, A

    2001-07-01

    In nerve injuries, if it is not possible to reinnervate muscle by using neurorrhaphy and nerve grafting technique, reinnervation should be provided by the use of neuroization-directly implanting motor nerve into muscle. A comparative study of three techniques of neurotization is presented in rabbits. In this experimental study, a total of 40 white New Zealand rabbits were used and divided into four groups, each including 10 rabbits. In the first group (control--Group 1), only surgical exposure of the gastrocnemius muscle, main muscle nerve (tibial nerve), and peroneal nerve was done, without any injury to the nerves. In the second group (direct neurotization group--Group 2), the tibial nerve was transected, and the peroneal nerve, which had already been divided into fascicles, was implanted into the lateral head of the gastrocnemius muscle aneural zone. In the third group (dual neurotization group--Group 3), the tibial nerve which had been transected and re-anastomosed, and the peroneal nerve were implanted into the lateral head of the gastrocnemius muscle. In the last experimental group (hyperneurotization group--Group 4), fascicles of the peroneal nerve were implanted into the lateral head of the gastrocnemius, preserving the tibial nerve. Six months later, changes in the histologic pattern and the functional recovery of the gastrocnemius muscle were investigated. It was found that functional recovery was achieved in all neurotization groups. Groups with the tibial nerve transected had less muscular weights than those of groups with the tibial nerve intact. EMG recordings showed that polyphasic and late potentials were frequently seen in groups with the tibial nerve transected. Degeneration and regeneration of myofibrils was observed in such groups as well. New motor end-plates, including vesicles, were formed in a scattered manner in all neurotization groups. As a result, the authors conclude that direct and dual neurotization techniques are useful in peripheral

  1. Direct torque control design and experimental evaluation for the brushless doubly fed machine

    International Nuclear Information System (INIS)

    Sarasola, Izaskun; Poza, Javier; Rodriguez, Miguel A.; Abad, Gonzalo

    2011-01-01

    In this paper, a direct torque control (DTC) strategy for the brushless doubly fed machine (BDFM) is presented. After analyzing the mathematical model of this machine, the voltage vectors look-up table of classical DTC techniques is derived. Then, the behavior of the machine is studied when it is controlled by the developed DTC technique, concluding that under some specific operation conditions, a BDFM could present a time interval where the torque and the flux can not be controlled simultaneously. In these cases, two different control solutions have been defined: 'flux priority' and 'torque priority'. Finally, simulation and experimental results validate the effectiveness of the proposed control algorithms.

  2. Evaluation of the efficacy of rumen cannulation technique on some rumen metabolic parameters in buffaloes

    Directory of Open Access Journals (Sweden)

    Gh. Manafiazar

    2010-02-01

    Full Text Available This experimental study was carried out to determine the efficacy of rumen cannulation technique on some rumen metabolic parameters in buffaloes. Four healthy male River (Azari buffaloes with no previous history of gastrointestinal dysfunction were chosen. There are several surgical techniques that can be used for rumen cannulation in farm animals, including buffaloes. This procedure was performed in a modified two-stage technique. In the first stage, the dorso – lateral portion of the dorsal sac of the rumen wall was sutured to the skin incision in the left para lumbar fossa region. In the second – stage, after six days left, the exposed rumen wall area was incised and the cannula was inserted and fixed manually in the rumenal opening incision site. In order to evaluate the efficacy of rumen cannulation technique on some rumen metabolic parameters, this study was achieved with different levels of NDF, and chewing behavior and their relationship with ruminal acidity, was measured in a change over design. Two diets with 2 levels of NDF were used as treatments. First and second diets had 52 and 47 % of NDF, respectively. Animals fed ad libitum at 09:00 and 21:00. There were no significant differences between chemical composition, particles distribution, geometric mean, its standard deviation and physically effective factor (pef of diets, dry matter intake (kg/d and nutrients intake (NDF, ADF, NFC and crude protein and their digestibility. Increasing NFC reduced ruminal pH at 0.5, 1.0, 4.5, 6.0 9.0 and 10.0 h post feeding. In addition, there were not significant differences on eating time, rumination time and total chewing activity between diets. All data obtained in this study were in normal range may indicating the efficacy of this cannulation method. More investigation should be done to determine the efficacy and comparison of the other surgical rumen cannulation techniques on Azari buffaloes of Iran.

  3. Wire-mesh and ultrasound techniques applied for the characterization of gas-liquid slug flow

    Energy Technology Data Exchange (ETDEWEB)

    Ofuchi, Cesar Y.; Sieczkowski, Wytila Chagas; Neves Junior, Flavio; Arruda, Lucia V.R.; Morales, Rigoberto E.M.; Amaral, Carlos E.F.; Silva, Marco J. da [Federal University of Technology of Parana, Curitiba, PR (Brazil)], e-mails: ofuchi@utfpr.edu.br, wytila@utfpr.edu.br, neves@utfpr.edu.br, lvrarruda@utfpr.edu.br, rmorales@utfpr.edu.br, camaral@utfpr.edu.br, mdasilva@utfpr.edu.br

    2010-07-01

    Gas-liquid two-phase flows are found in a broad range of industrial applications, such as chemical, petrochemical and nuclear industries and quite often determine the efficiency and safety of process and plants. Several experimental techniques have been proposed and applied to measure and quantify two-phase flows so far. In this experimental study the wire-mesh sensor and an ultrasound technique are used and comparatively evaluated to study two-phase slug flows in horizontal pipes. The wire-mesh is an imaging technique and thus appropriated for scientific studies while ultrasound-based technique is robust and non-intrusive and hence well suited for industrial applications. Based on the measured raw data it is possible to extract some specific slug flow parameters of interest such as mean void fraction and characteristic frequency. The experiments were performed in the Thermal Sciences Laboratory (LACIT) at UTFPR, Brazil, in which an experimental two-phase flow loop is available. The experimental flow loop comprises a horizontal acrylic pipe of 26 mm diameter and 9 m length. Water and air were used to produce the two phase flow under controlled conditions. The results show good agreement between the techniques. (author)

  4. Experimental design technique applied to the validation of an instrumental Neutron Activation Analysis procedure

    International Nuclear Information System (INIS)

    Santos, Uanda Paula de M. dos; Moreira, Edson Gonçalves

    2017-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) method were carried out for the determination of the elements bromine, chlorine, magnesium, manganese, potassium, sodium and vanadium in biological matrix materials using short irradiations at a pneumatic system. 2 k experimental designs were applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. The chosen experimental designs were the 2 3 and the 2 4 , depending on the radionuclide half life. Different certified reference materials and multi-element comparators were analyzed considering the following variables: sample decay time, irradiation time, counting time and sample distance to detector. Comparator concentration, sample mass and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations, it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN /CNEN-SP). Optimized conditions were estimated based on the results of z-score tests, main effect, interaction effects and better irradiation conditions. (author)

  5. Experimental design technique applied to the validation of an instrumental Neutron Activation Analysis procedure

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Uanda Paula de M. dos; Moreira, Edson Gonçalves, E-mail: uandapaula@gmail.com, E-mail: emoreira@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) method were carried out for the determination of the elements bromine, chlorine, magnesium, manganese, potassium, sodium and vanadium in biological matrix materials using short irradiations at a pneumatic system. 2{sup k} experimental designs were applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. The chosen experimental designs were the 2{sup 3} and the 2{sup 4}, depending on the radionuclide half life. Different certified reference materials and multi-element comparators were analyzed considering the following variables: sample decay time, irradiation time, counting time and sample distance to detector. Comparator concentration, sample mass and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations, it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN /CNEN-SP). Optimized conditions were estimated based on the results of z-score tests, main effect, interaction effects and better irradiation conditions. (author)

  6. Development and experimental evaluation of theoretical models for ion cyclotron resonance frequency heating of tokamak plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Mantsinen, M. [Helsinki Univ. of Technology, Espoo (Finland). Dept. of Technical Physics

    1999-06-01

    Heating with electromagnetic waves in the ion cyclotron range of frequencies (ICRF) is a well-established method for auxiliary heating of present-day tokamak plasmas and is envisaged as one of the main heating techniques for the International Thermonuclear Experimental Reactor (ITER) and future reactor plasmas. In order to predict the performance of ICRF heating in future machines, it is important to benchmark present theoretical modelling with experimental results on present tokamaks. This thesis reports on development and experimental evaluation of theoretical models for ICRF heating at the Joint European Torus (JET). Several ICRF physics effects and scenarios have been studied. Direct importance to the ITER is the theoretical analysis of ICRF heating experiments with deuterium-tritium (D-T) plasmas. These experiments clearly demonstrate the potential of ICRF heating for auxiliary heating of reactor plasmas. In particular, scenarios with potential for good bulk ion heating and enhanced D-T fusion reactivity have been identified. Good bulk ion heating is essential for reactor plasmas in order to obtain a high ion temperature and a high fusion reactivity. In JET good bulk ion heating with ICRF waves has been achieved in high-performance discharges by adding ICRF heating to neutral beam injection. In these experiments, as in other JET discharges where damping at higher harmonics of the ion cyclotron frequency takes place, so-called finite Larmor radius (FLR) effects play an important role. Due to FLR effects, the resonating ion velocity distribution function can have a strong influence on the power deposition. Evidence for this effect has been obtained from the third harmonic deuterium heating experiments. Because of FLR effects, the wave-particle interaction can also become weak at certain ion energies, which prevents resonating ions from reaching higher energies. When interacting with the wave, an ion receives not only a change in energy but also a change in

  7. Applications of energy-release-rate techniques to part-through cracks in experimental pressure vessels

    International Nuclear Information System (INIS)

    Bass, B.R.; Bryan, R.H.; Bryson, J.W.; Merkle, J.G.

    1982-01-01

    In nonlinear applications of computational fracture mechanics, energy release rate techniques are used increasingly for computing stress intensity parameters of crack configurations. Recently, deLorenzi used the virtual-crack-extension method to derive an analytical expression for the energy release rate that is better suited for three-dimensional calculations than the well-known J-integral. Certain studies of fracture phenomena, such as pressurized-thermal-shock of cracked structures, require that crack tip parameters be determined for combined thermal and mechanical loads. A method is proposed here that modifies the isothermal formulation of deLorenzi to account for thermal strains in cracked bodies. This combined thermo-mechanical formulation of the energy release rate is valid for general fracture, including nonplanar fracture, and applies to thermo-elastic as well as deformation plasticity material models. Two applications of the technique are described here. In the first, semi-elliptical surface cracks in an experimental test vessel are analyzed under elastic-plastic conditions using the finite element method. The second application is a thick-walled test vessel subjected to combined pressure and thermal shock loadings

  8. Evaluation of Anomaly Detection Techniques for SCADA Communication Resilience

    OpenAIRE

    Shirazi, Syed Noor Ul Hassan; Gouglidis, Antonios; Syeda, Kanza Noor; Simpson, Steven; Mauthe, Andreas Ulrich; Stephanakis, Ioannis M.; Hutchison, David

    2016-01-01

    Attacks on critical infrastructures’ Supervisory Control and Data Acquisition (SCADA) systems are beginning to increase. They are often initiated by highly skilled attackers, who are capable of deploying sophisticated attacks to exfiltrate data or even to cause physical damage. In this paper, we rehearse the rationale for protecting against cyber attacks and evaluate a set of Anomaly Detection (AD) techniques in detecting attacks by analysing traffic captured in a SCADA network. For this purp...

  9. Effects of organic amendments on water use efficiency evaluated by a stable isotope technique. A case study in experimental mine restoration.

    Science.gov (United States)

    Luna Ramos, Lourdes; Delgado Huertas, Antonio; Miralles Mellado, Isabel; Solé Benet, Albert

    2017-04-01

    Water deficit and low infiltration reduce restoration success in semiarid post-mine soils, where high mortality of plants has been observed in early years of the restoration. Species that originate from arid and semi-arid regions are often considered appropriate for xeriscaping, but there have been relatively few direct measurements of main water related parameters as water use efficiency (WUE) in restoration strategies. In this respect, the goal of this study was to analyse the efficiency with which native plants use water when organic amendments and mulches are applied in mine soil restorations. The experimental design was established in a calcareous quarry in Almería (SE Spain), under arid climate. We tested two organic amendments (sewage sludge from water treatment plant and compost from vegetable residues) and gravel mulch. Three plant species were planted in 50 m2 experimental plots: Macrochloa tenacissima, Genista umbellata and Anthyllis cytisoides. Soil moisture was monitored at a depth of 0.1 m during 4 years and at the end of this period stable isotope of Carbon (δ13C), considered as an effective method to evaluate the plant intrinsic WUE, was measured. We did not observe significant differences in soil moisture among the different soil restoration treatments. With regard to WUE, species is the factor most important to establish differences. Anthyllis cytisoides showed the lowest mean δ13C values, indicating low WUE. On the contrary, Macrochloa tenacissima presented high δ13C values. Moreover, species showed higher δ13C values when gravel mulch was applied. To increase WUE in restored soils under arid conditions it is necessary to apply water conservation methods and to use the most appropriate species.

  10. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation...

  11. Evaluation and Visualization of Surface Defects - a Numerical and Experimental Study on Sheet-Metal Parts

    International Nuclear Information System (INIS)

    Andersson, A.

    2005-01-01

    The ability to predict surface defects in outer panels is of vital importance in the automotive industry, especially for brands in the premium car segment. Today, measures to prevent these defects can not be taken until a test part has been manufactured, which requires a great deal of time and expense. The decision as to whether a certain surface is of acceptable quality or not is based on subjective evaluation. It is quite possible to detect a defect by measurement, but it is not possible to correlate measured defects and the subjective evaluation. If all results could be based on the same criteria, it would be possible to compare a surface by both FE simulations, experiments and subjective evaluation with the same result.In order to find a solution concerning the prediction of surface defects, a laboratory tool was manufactured and analysed both experimentally and numerically. The tool represents the area around a fuel filler lid and the aim was to recreate surface defects, so-called 'teddy bear ears'. A major problem with the evaluation of such defects is that the panels are evaluated manually and to a great extent subjectivity is involved in the classification and judgement of the defects. In this study the same computer software was used for the evaluation of both the experimental and the numerical results. In this software the surface defects were indicated by a change in the curvature of the panel. The results showed good agreement between numerical and experimental results. Furthermore, the evaluation software gave a good indication of the appearance of the surface defects compared to an analysis done in existing tools for surface quality measurements. Since the agreement between numerical and experimental results was good, this indicates that these tools can be used for an early verification of surface defects in outer panels

  12. Performance Evaluation of Frequency Transform Based Block Classification of Compound Image Segmentation Techniques

    Science.gov (United States)

    Selwyn, Ebenezer Juliet; Florinabel, D. Jemi

    2018-04-01

    Compound image segmentation plays a vital role in the compression of computer screen images. Computer screen images are images which are mixed with textual, graphical, or pictorial contents. In this paper, we present a comparison of two transform based block classification of compound images based on metrics like speed of classification, precision and recall rate. Block based classification approaches normally divide the compound images into fixed size blocks of non-overlapping in nature. Then frequency transform like Discrete Cosine Transform (DCT) and Discrete Wavelet Transform (DWT) are applied over each block. Mean and standard deviation are computed for each 8 × 8 block and are used as features set to classify the compound images into text/graphics and picture/background block. The classification accuracy of block classification based segmentation techniques are measured by evaluation metrics like precision and recall rate. Compound images of smooth background and complex background images containing text of varying size, colour and orientation are considered for testing. Experimental evidence shows that the DWT based segmentation provides significant improvement in recall rate and precision rate approximately 2.3% than DCT based segmentation with an increase in block classification time for both smooth and complex background images.

  13. Identification and evaluation of facilitation techniques for decommissioning light water power reactors

    International Nuclear Information System (INIS)

    LaGuardia, T.S.; Risley, J.F.

    1986-06-01

    This report describes a study sponsored by the US Nuclear Regulatory Commission to identify practical techniques to facilitate the decommissioning of nuclear power generating facilities. The objective of these ''facilitation techniques'' is to reduce the radioactive exposures and/or volumes of waste generated during the decommissioning process. The report presents the possible facilitation techniques identified during the study and discusses the corresponding facilitation of the decommissioning process. Techniques are categorized by their applicability of being implemented during the three stages of power reactor life: design/construction, operation, or decommissioning. Detailed cost-benefit analyses were performed for each technique to determine the anticipated exposure and/or radioactive waste reduction; the estimated costs for implementing each technique were then calculated. Finally, these techniques were ranked by their effectiveness in facilitating the decommissioning process. This study is a part of the Nuclear Regulatory Commission's evaluation of decommissioning policy and its modification of regulations pertaining to the decommissioning process. The findings can be used by the utilities in the planning and establishment of activities to ensure that all objectives of decommissioning will be achieved

  14. One-flap Palatoplasty: A Cohort Study to Evaluate a Technique for Unilateral Cleft Palate Repair

    Directory of Open Access Journals (Sweden)

    Percy Rossell-Perry, PhD, FACS

    2015-04-01

    Conclusions: Use of a 1-flap technique for unilateral cleft palate repair allowed us to achieve results comparable to those of a 2-flap technique in terms of postoperative fistula development and hypernasal speech. Additional studies are required to evaluate the effect of this technique on palatal growth.

  15. Data verification and evaluation techniques for groundwater monitoring programs

    International Nuclear Information System (INIS)

    Mercier, T.M.; Turner, R.R.

    1990-12-01

    To ensure that data resulting from groundwater monitoring programs are of the quality required to fulfill program objectives, it is suggested that a program of data verification and evaluation be implemented. These procedures are meant to supplement and support the existing laboratory quality control/quality assurance programs by identifying aberrant data resulting from a variety of unforeseen circumstances: sampling problems, data transformations in the lab, data input at the lab, data transfer, end-user data input. Using common-sense principles, pattern recognition techniques, and hydrogeological principles, a computer program was written which scans the data for suspected abnormalities and produces a text file stating sample identifiers, the suspect data, and a statement of how the data has departed from the expected. The techniques described in this paper have been developed to support the Y-12 Plant Groundwater Protection Program Management Plan

  16. Experimental diode laser-assisted microvascular anastomosis.

    Science.gov (United States)

    Reali, U M; Gelli, R; Giannotti, V; Gori, F; Pratesi, R; Pini, R

    1993-05-01

    An experimental study to evaluate a diode-laser approach to microvascular end-to-end anastomoses is reported. Studies were carried out on the femoral arteries and veins of Wistar rats, and effective welding of vessel tissue was obtained at low laser power, by enhancing laser absorption with indocyanine green (Cardio-green) solution. The histologic and surgical effects of this laser technique were examined and compared with those of conventional microvascular sutured anastomoses.

  17. Two biased estimation techniques in linear regression: Application to aircraft

    Science.gov (United States)

    Klein, Vladislav

    1988-01-01

    Several ways for detection and assessment of collinearity in measured data are discussed. Because data collinearity usually results in poor least squares estimates, two estimation techniques which can limit a damaging effect of collinearity are presented. These two techniques, the principal components regression and mixed estimation, belong to a class of biased estimation techniques. Detection and assessment of data collinearity and the two biased estimation techniques are demonstrated in two examples using flight test data from longitudinal maneuvers of an experimental aircraft. The eigensystem analysis and parameter variance decomposition appeared to be a promising tool for collinearity evaluation. The biased estimators had far better accuracy than the results from the ordinary least squares technique.

  18. Thyroidal radio autographic evaluation in experimental diabetes mellitus

    International Nuclear Information System (INIS)

    Nascimento-Saba, C.C.A.; Brito, A.C.; Pereira, M.J.S.; Carvalho, J.J.; Roshental, D.

    1997-01-01

    Full text. There is a well known correlation between diabetes mellitus (DM) and thyroid diseases. Previous studies have shown that the thyroid peroxidase (TPO) 'in vitro' iodide-oxidation activity is decreased and the thyroid T 4-dasanide is increased 15 days after induction of experimental DM. In the present study we evaluated radioautography, an indirect assay of 'in vivo' T P O activity. D M was induced in male Wistar rats (circa 250 g body weight) by a single i.p. streptozotocin injection (45 mg/kg). One group of D M animals received insulin (2 U/day, N P H), starting 48 h after streptozotocin. 2μ Ci of 125 I were given by i.p. injection, 2.5 h before thyroid excision, after 7 or 30 days of diabetes. The glands were counted, weighed, fixed in Bouin's solution, embedded in paraffin, cut and HE-stained. The sections were covered with NTB-2 emulsion (Kodak), incubated at 4 deg C for 7 days, before revelation. Quantitative distribution of silver grains was evaluated using the Image Pro-Plus program. The thyroidal 125 I uptake is significantly decreased in diabetic animals after 30 days. The 'in vative P O activity is significantly decreased 7 and 30 days D M induction. This decrease was also present in the insulin-treated animals and the exogenous insulin administration was unable to revert changes induced by experimental D M, at least in the dosage/periodicity used. It seems that the activity of basal membrane is affected after 30 days of D M, however the T P O activity is already affected after 7 days of DM

  19. The coupling of high-speed high resolution experimental data and LES through data assimilation techniques

    Science.gov (United States)

    Harris, S.; Labahn, J. W.; Frank, J. H.; Ihme, M.

    2017-11-01

    Data assimilation techniques can be integrated with time-resolved numerical simulations to improve predictions of transient phenomena. In this study, optimal interpolation and nudging are employed for assimilating high-speed high-resolution measurements obtained for an inert jet into high-fidelity large-eddy simulations. This experimental data set was chosen as it provides both high spacial and temporal resolution for the three-component velocity field in the shear layer of the jet. Our first objective is to investigate the impact that data assimilation has on the resulting flow field for this inert jet. This is accomplished by determining the region influenced by the data assimilation and corresponding effect on the instantaneous flow structures. The second objective is to determine optimal weightings for two data assimilation techniques. The third objective is to investigate how the frequency at which the data is assimilated affects the overall predictions. Graduate Research Assistant, Department of Mechanical Engineering.

  20. AN EVALUATION OF CONDITION MONITORING TECHNIQUES FOR LOW-VOLTAGE ELECTRIC CABLES

    International Nuclear Information System (INIS)

    LOFARO, R.J.; GROVE, E.; SOO, P.

    2000-01-01

    Aging of systems and components in nuclear power plants is a well known occurrence that must be managed to ensure the continued safe operation of these plants. Much of the degradation due to aging is controlled through periodic maintenance and/or component replacement. However, there are components that do not receive periodic maintenance or monitoring once they are installed; electric cables are such a component. To provide a means of monitoring the condition of electric cables, research is ongoing to evaluate promising condition monitoring (CM) techniques that can be used in situ to monitor cable condition and predict remaining life. While several techniques are promising, each has limitations that must be considered in its application. This paper discusses the theory behind several of the promising cable CM techniques being studied, along with their effectiveness for monitoring aging degradation in typical cable insulation materials, such as cross-linked polyethylene and ethylene propylene rubber. Successes and limitations of each technique are also presented

  1. Evaluation of Clipping Based Iterative PAPR Reduction Techniques for FBMC Systems

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2014-01-01

    to conventional orthogonal frequency division multiplexing (OFDM technique. The low ACLR of the transmitted FBMC signal makes it especially favorable in cognitive radio applications, where strict requirements are posed on out-of-band radiation. Large dynamic range resulting in high peak-to-average power ratio (PAPR is characteristic of all sorts of multicarrier signals. The advantageous spectral properties of the high-PAPR FBMC signal are significantly degraded if nonlinearities are present in the transceiver chain. Spectral regrowth may appear, causing harmful interference in the neighboring frequency bands. This paper presents novel clipping based PAPR reduction techniques, evaluated and compared by simulations and measurements, with an emphasis on spectral aspects. The paper gives an overall comparison of PAPR reduction techniques, focusing on the reduction of the dynamic range of FBMC signals without increasing out-of-band radiation. An overview is presented on transmitter oriented techniques employing baseband clipping, which can maintain the system performance with a desired bit error rate (BER.

  2. Evaluation of the effect of conventionally prepared swarna makshika bhasma on different bio-chemical parameters in experimental animals

    Directory of Open Access Journals (Sweden)

    Sudhaldev Mohapatra

    2011-01-01

    Full Text Available Swarna makshika (chalcopyrite bhasma (SMB has been used for different therapeutic purposes since long in Ayurveda. The present study is conducted to evaluate the effect of conventionally prepared SMB on different bio-chemical parameters in experimental animals, for providing scientific data base for its logical use in clinical practice. The genuine SMB was prepared by following classical techniques of shodhana and marana most commonly used by different Ayurvedic drug manufacturers. Shodhana was done by roasting raw swarna makshika with lemon juice for three days and marana was performed by 11 putas . The experimental animals (rats were divided into two groups. SMB mixed with diluted honey was administered orally in therapeutic dose to Group SMB and diluted honey only was administered to vehicle control Group, for 30 days. The blood samples were collected twice, after 15 days and after 30 days of drug administration and different biochemical investigations were done. Biochemical parameters were chosen based on references from Ayurvedic classics and contemporary medicine. It was observed that Hb% was found significantly increased and LDL and VLDL were found significantly decreased in Group SMB when compared with vehicle control group. This experimental data will help the clinician for the logical use of SMB in different disease conditions with findings like low Hb% and high LDL, VLDL levels.

  3. Simulation and evaluation of the absorption edge subtraction technique in energy-resolved X-ray radiography applied to the cultural heritage studies

    International Nuclear Information System (INIS)

    Leyva Pernia, Diana; Cabal Rodriguez, Ana E.; Pinnera Hernandez, Ibrahin; Leyva Fabelo, Antonio; Abreu Alfonso, Yamiel; Espen, Piet Van

    2011-01-01

    In this work the mathematical simulation of photon transport in the matter was used to evaluate the potentials of a new energy-resolved X-ray radiography system. The system is intended for investigations of cultural heritage object, mainly painting. The radiographic system uses polychromatic radiation from an X-ray tube and measures the spectrum transmitted through the object with an energy-dispersive X-ray detector on a pixel-by-pixel basis. Manipulation of the data-set obtained allows constructing images with enhanced contrast for certain elements. Here the use of the absorption edge subtraction technique was emphasized. The simulated results were in good agreement with the experimental data.(author)

  4. Development of PSI and ISI technique

    International Nuclear Information System (INIS)

    Chung, M.K.; Park, D.Y.; Choi, S.P.; Kim, H.J.; Moon, Y.S.; Shon, G.H.; Kim, T.S.

    1983-01-01

    This report describes the experimental results of the subjects selected from the PSI/ISI related problems which encountered by us in 1982. The main contents are 1) the characteristics of the typical ECT signals from the steam generator tubes of nuclear power plant and the results of ECT evaluation of Kori-1 steam generators, 2) the experimental result for the research for directional effects of ultrasonic transducers, 3) the basic experiment for the ultrasonic testing technique by immersion testing method, 4) how to write the scan plan of the mechanized ultrasonic testing for nuclear reactor. Attached appendix is a part of necessary materials for the scan plan of the mechanized ultrasonic testing for Kori-2 nuclear reactor. (Author)

  5. Convenience experimentation.

    Science.gov (United States)

    Krohs, Ulrich

    2012-03-01

    Systems biology aims at explaining life processes by means of detailed models of molecular networks, mainly on the whole-cell scale. The whole cell perspective distinguishes the new field of systems biology from earlier approaches within molecular cell biology. The shift was made possible by the high throughput methods that were developed for gathering 'omic' (genomic, proteomic, etc.) data. These new techniques are made commercially available as semi-automatic analytic equipment, ready-made analytic kits and probe arrays. There is a whole industry of supplies for what may be called convenience experimentation. My paper inquires some epistemic consequences of strong reliance on convenience experimentation in systems biology. In times when experimentation was automated to a lesser degree, modeling and in part even experimentation could be understood fairly well as either being driven by hypotheses, and thus proceed by the testing of hypothesis, or as being performed in an exploratory mode, intended to sharpen concepts or initially vague phenomena. In systems biology, the situation is dramatically different. Data collection became so easy (though not cheap) that experimentation is, to a high degree, driven by convenience equipment, and model building is driven by the vast amount of data that is produced by convenience experimentation. This results in a shift in the mode of science. The paper shows that convenience driven science is not primarily hypothesis-testing, nor is it in an exploratory mode. It rather proceeds in a gathering mode. This shift demands another shift in the mode of evaluation, which now becomes an exploratory endeavor, in response to the superabundance of gathered data. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Evaluating empirical/analytical techniques to predict structural integrity of pipe containing surface flaws

    International Nuclear Information System (INIS)

    Reuter, W.G.; Server, W.L.

    1982-01-01

    Data from flat-plate specimens containing either triangular-, ellipsoidal- or rectangular-shaped surface flaws were evaluated by several potential analytical techniques. These techniques were modified as needed to predict conditions for initiation of subcritical crack growth, for the defect to penetrate the 6.4 mm (0.25 in.) wall thickness, and for instability (plastic or unstable). The modified analytical techniques developed from the plate specimens were then used to make predictions which are compared with test results obtained from pipe specimens containing triangular-shaped surface flaws

  7. Evaluation of techniques for determining the density of fine woody debris

    Science.gov (United States)

    Becky Fasth; Mark E. Harmon; Christopher W. Woodall; Jay. Sexton

    2010-01-01

    Evaluated various techniques for determining the density (i.e., bulk density) of fine woody debris during forest inventory activities. It was found that only experts in dead wood inventory may be able to identify fine woody debris stages of decay. Suggests various future research directions such as...

  8. New techniques for experimental generation of two-dimensional blade-vortex interaction at low Reynolds numbers

    Science.gov (United States)

    Booth, E., Jr.; Yu, J. C.

    1986-01-01

    An experimental investigation of two dimensional blade vortex interaction was held at NASA Langley Research Center. The first phase was a flow visualization study to document the approach process of a two dimensional vortex as it encountered a loaded blade model. To accomplish the flow visualization study, a method for generating two dimensional vortex filaments was required. The numerical study used to define a new vortex generation process and the use of this process in the flow visualization study were documented. Additionally, photographic techniques and data analysis methods used in the flow visualization study are examined.

  9. Experimental evaluation of J in cracked straight and curved pipes under bending

    International Nuclear Information System (INIS)

    Moulin, D.; Touboul, F.; Foucher, N.; Lebey, J.; Acker, D.

    1989-01-01

    An experimental program is being carried out at the CEA Saclay in collaboration with FRAMATOME and IPSN with a view to validate analysis methods applicable for evaluation of leak before break behavior in P.W.R. piping. A large experimental work was already performed in USA, Germany and Japan and cracked pipes made of stainless steel material under bending. The methods of analysis got same validations for straight pipes. However applicability to elbows and comparison with toughness values obtained on small specimens like CT specimens was not completely dealt with

  10. Experimental Support for Evaluation of the Victoria Class Virtual Submarine (VCVS)

    Science.gov (United States)

    2012-03-01

    comportementales de ce genre . y A P P R O V A L S H E E T Document No. 5283-001 Version 03 Document Name: Experimental Support for Evaluation...encountered that reduced access to HMCS Corner Brook: 11  Cold moves to charge submarine batteries;  Filming events; and,  Slight delays due

  11. Evaluation of stabilization techniques for ion implant processing

    Science.gov (United States)

    Ross, Matthew F.; Wong, Selmer S.; Minter, Jason P.; Marlowe, Trey; Narcy, Mark E.; Livesay, William R.

    1999-06-01

    With the integration of high current ion implant processing into volume CMOS manufacturing, the need for photoresist stabilization to achieve a stable ion implant process is critical. This study compares electron beam stabilization, a non-thermal process, with more traditional thermal stabilization techniques such as hot plate baking and vacuum oven processing. The electron beam processing is carried out in a flood exposure system with no active heating of the wafer. These stabilization techniques are applied to typical ion implant processes that might be found in a CMOS production process flow. The stabilization processes are applied to a 1.1 micrometers thick PFI-38A i-line photoresist film prior to ion implant processing. Post stabilization CD variation is detailed with respect to wall slope and feature integrity. SEM photographs detail the effects of the stabilization technique on photoresist features. The thermal stability of the photoresist is shown for different levels of stabilization and post stabilization thermal cycling. Thermal flow stability of the photoresist is detailed via SEM photographs. A significant improvement in thermal stability is achieved with the electron beam process, such that photoresist features are stable to temperatures in excess of 200 degrees C. Ion implant processing parameters are evaluated and compared for the different stabilization methods. Ion implant system end-station chamber pressure is detailed as a function of ion implant process and stabilization condition. The ion implant process conditions are detailed for varying factors such as ion current, energy, and total dose. A reduction in the ion implant systems end-station chamber pressure is achieved with the electron beam stabilization process over the other techniques considered. This reduction in end-station chamber pressure is shown to provide a reduction in total process time for a given ion implant dose. Improvements in the ion implant process are detailed across

  12. Collimator performance evaluation by Monte-Carlo techniques

    International Nuclear Information System (INIS)

    Milanesi, L.; Bettinardi, V.; Bellotti, E.; Gilardi, M.C.; Todd-Pokropek, A.; Fazio, F.

    1985-01-01

    A computer program using Monte-Carlo techniques has been developed to simulate gamma camera collimator performance. Input data include hole length, septum thickness, hole size and shape, collimator material, source characteristics, source to collimator distance and medium, radiation energy, total events number. Agreement between Monte-Carlo simulations and experimental measurements was found for commercial hexagonal parallel hole collimators in terms of septal penetration, transfer function and sensitivity. The method was then used to rationalize collimator design for tomographic brain studies. A radius of ration of 15 cm was assumed. By keeping constant resolution at 15 cm (FWHM = 1.3.cm), SPECT response to a point source was obtained in scattering medium for three theoretical collimators. Sensitivity was maximized in the first collimator, uniformity of resolution response in the third, while the second represented a trade-off between the two. The high sensitivity design may be superior in the hot spot and/or low activity situation, while for distributed sources of high activity an uniform resolution response should be preferred. The method can be used to personalize collimator design to different clinical needs in SPECT

  13. Waste treatment in NUCEF facility with silver mediated electrochemical oxidation technique

    International Nuclear Information System (INIS)

    Umeda, M.; Sugikawa, S.

    2000-01-01

    Silver mediated electrochemical oxidation technique has been considered one of promising candidates for alpha-bearing waste treatment. Destruction tests of organic compounds, such as insoluble tannin, TBP and dodecane, were carried out by this technique and the experimental data such as destruction rates, current efficiencies and intermediates were obtained. These compounds could be completely mineralized without the formation of reactive organic nitrate associated to safety hazards. On the basis of these results, the applicability of silver mediated electrochemical oxidation technique to waste treatment in NUCEF was evaluated. (authors)

  14. Experimental investigation of the predictive capabilities of data driven modeling techniques in hydrology - Part 1: Concepts and methodology

    Directory of Open Access Journals (Sweden)

    A. Elshorbagy

    2010-10-01

    Full Text Available A comprehensive data driven modeling experiment is presented in a two-part paper. In this first part, an extensive data-driven modeling experiment is proposed. The most important concerns regarding the way data driven modeling (DDM techniques and data were handled, compared, and evaluated, and the basis on which findings and conclusions were drawn are discussed. A concise review of key articles that presented comparisons among various DDM techniques is presented. Six DDM techniques, namely, neural networks, genetic programming, evolutionary polynomial regression, support vector machines, M5 model trees, and K-nearest neighbors are proposed and explained. Multiple linear regression and naïve models are also suggested as baseline for comparison with the various techniques. Five datasets from Canada and Europe representing evapotranspiration, upper and lower layer soil moisture content, and rainfall-runoff process are described and proposed, in the second paper, for the modeling experiment. Twelve different realizations (groups from each dataset are created by a procedure involving random sampling. Each group contains three subsets; training, cross-validation, and testing. Each modeling technique is proposed to be applied to each of the 12 groups of each dataset. This way, both prediction accuracy and uncertainty of the modeling techniques can be evaluated. The description of the datasets, the implementation of the modeling techniques, results and analysis, and the findings of the modeling experiment are deferred to the second part of this paper.

  15. Data interpretation, objective evaluation procedures and mathematical techniques for the evaluation of energy-dependent ratio, shape and cross section data

    International Nuclear Information System (INIS)

    Poenitz, W.P.

    1980-01-01

    The evaluation of several energy-dependent neutron cross sections which are of importance for practical applications is considered. The evaluation process is defined as the procedure which is used to derive the best knowledge of these cross sections based on the available direct experimental data information, and, using theoretical models, on the auxiliary data base. The experimental data base represents a multiple overdetermination of the unknown cross sections with various correlations between the measured values. Obtaining the least-squares estimator is considered as the standard mathematical procedure to derive a consistent set of evaluated cross section values. Various approximations made in order to avoid the monstrous system of normal equations are considered and the feasibility of the exact solution is demonstrated. The variance-covariance of the result, its reliability and the improvements obtained in iterative steps are discussed. Finally, the inclusion of auxiliary, supplementary information is considered. 45 references

  16. Experimental Evaluation of Actinide Transport in a Fractured Granodiorite

    Energy Technology Data Exchange (ETDEWEB)

    Dittrich, Timothy M. [Los Alamos National Laboratory; Reimus, Paul W. [Los Alamos National Laboratory

    2015-03-16

    The objective of this study was to demonstrate and evaluate new experimental methods for quantifying the potential for actinide transport in deep fractured crystalline rock formations. We selected a fractured granodiorite at the Grimsel Test Site (GTS) in Switzerland as a model system because field experiments have already been conducted with uranium and additional field experiments using other actinides are planned at the site. Thus, working on this system provides a unique opportunity to compare lab experiment results with fieldscale observations. Rock cores drilled from the GTS were shipped to Los Alamos National Laboratory, characterized by x-ray diffraction and microscopy, and used in batch sorption and column breakthrough experiments. Solutions with pH 6.8 and 8.8 were tested. Solutions were switched to radionuclide-free synthetic Grimsel groundwater after near-steady actinide/colloid breakthrough occurred in column experiments. We are currently evaluating actinide adsorption/desorption rates as a function of water chemistry (initial focus on pH), with future testing planned to evaluate the influence of carbonate concentrations, flow rates, and mineralogy in solutions and suspensions with bentonite colloids. (auth)

  17. Experimental Flow Performance Evaluation of novel miniaturized Advanced Piezoelectric Dual Cooling Jet

    International Nuclear Information System (INIS)

    De Bock, H P J; Whalen, B P; Chamarthy, P; Jackson, J L

    2012-01-01

    In recent years, electronics systems have significantly reduced in size at maintained or increased functionality. This trend has led to an increased demand for smaller and more capable thermal management. However, miniaturization of conventional fan and heat sink cooling systems introduce significant size, weight and efficiency challenges. In this study the flow performance of a novel alternative thin form-factor cooling solution, the advanced piezoelectric dual cooling jet(DCJ), is evaluated. A DCJ is a system where two piezoelectric actuators are excited to produce air flow. The total height of the device is about 1mm. The design of the experimental method for evaluating the equivalent fan-curve of the DCJ device is described in detail. Experimental results in comparison to conventional fan solutions are provided. The DCJ is expected to be a good candidate for thermal management in next generation thin profile consumer electronics.

  18. The role of chemometrics in single and sequential extraction assays: a review. Part II. Cluster analysis, multiple linear regression, mixture resolution, experimental design and other techniques.

    Science.gov (United States)

    Giacomino, Agnese; Abollino, Ornella; Malandrino, Mery; Mentasti, Edoardo

    2011-03-04

    Single and sequential extraction procedures are used for studying element mobility and availability in solid matrices, like soils, sediments, sludge, and airborne particulate matter. In the first part of this review we reported an overview on these procedures and described the applications of chemometric uni- and bivariate techniques and of multivariate pattern recognition techniques based on variable reduction to the experimental results obtained. The second part of the review deals with the use of chemometrics not only for the visualization and interpretation of data, but also for the investigation of the effects of experimental conditions on the response, the optimization of their values and the calculation of element fractionation. We will describe the principles of the multivariate chemometric techniques considered, the aims for which they were applied and the key findings obtained. The following topics will be critically addressed: pattern recognition by cluster analysis (CA), linear discriminant analysis (LDA) and other less common techniques; modelling by multiple linear regression (MLR); investigation of spatial distribution of variables by geostatistics; calculation of fractionation patterns by a mixture resolution method (Chemometric Identification of Substrates and Element Distributions, CISED); optimization and characterization of extraction procedures by experimental design; other multivariate techniques less commonly applied. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Dissociative Recombination of HD+ - State-to-State Experimental Investigation Using Fragment Imaging and Storage Ring Techniques

    International Nuclear Information System (INIS)

    Amitay, Z.; Baer, A.; Dahan, M.; Levin, J.; Vager, Z.; Zajfman, D.

    1998-01-01

    When a molecular ion collides with a free electron it can capture the electron and dissociate. The resulting process of Dissociative Recombination (DR) is a process of great significance in a wide variety of plasma environments. In this process, the capture of a free electron leads to the formation of an highly excited state of the neutral molecule, which then dissociates into neutral fragments with kinetic energy and, possibly, internal excitation depending on the energy balance of the reaction. Despite its importance, the DR process is still not yet completely understood theoretically. This is mainly due to the complexity of the nature and dynamics of highly excited molecular states, especially when several channels are involved, as is usually the situation in DR. from experimental point of view, for direct comparison between experiment and theory, this complexity requires detailed experimental data, including the knowledge of both the initial state of the molecular ion, to which DR is very sensitive, and of the final quantum states of the DR products. Inherent un- certainties in the initial vibrational excitation of the laboratory molecular ions was the main drawback of the experiments conducted over the years to, study DR. A substantial progress in the understanding of the DR process was achieved with the introduction (about five years ago) of a new experimental approach, which uses heavy-ion storage ring technique. In a storage ring, one can store many molecular ions for a time which is long enough to allow complete radiative deexcitation of tile initial electronic and vibrational excitation coming from the ion source. Those vibrationally cold ions are then merged with an intense electron beam to measure their DR cross section. Further experimental progress was the inclusion of two and three-dimensional molecular imaging techniques [1] for the measurement of the branching ratio to different final quantum states of the neutral DR fragments. This talk will

  20. Multi-scale full-field measurements and near-wall modeling of turbulent subcooled boiling flow using innovative experimental techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Yassin A., E-mail: y-hassan@tamu.edu

    2016-04-01

    Highlights: • Near wall full-field velocity components under subcooled boiling were measured. • Simultaneous shadowgraphy, infrared thermometry wall temperature and particle-tracking velocimetry techniques were combined. • Near wall velocity modifications under subcooling boiling were observed. - Abstract: Multi-phase flows are one of the challenges on which the CFD simulation community has been working extensively with a relatively low success. The phenomena associated behind the momentum and heat transfer mechanisms associated to multi-phase flows are highly complex requiring resolving simultaneously for multiple scales on time and space. Part of the reasons behind the low predictive capability of CFD when studying multi-phase flows, is the scarcity of CFD-grade experimental data for validation. The complexity of the phenomena and its sensitivity to small sources of perturbations makes its measurements a difficult task. Non-intrusive and innovative measuring techniques are required to accurately measure multi-phase flow parameters while at the same time satisfying the high resolution required to validate CFD simulations. In this context, this work explores the feasible implementation of innovative measuring techniques that can provide whole-field and multi-scale measurements of two-phase flow turbulence, heat transfer, and boiling parameters. To this end, three visualization techniques are simultaneously implemented to study subcooled boiling flow through a vertical rectangular channel with a single heated wall. These techniques are listed next and are used as follow: (1) High-speed infrared thermometry (IR-T) is used to study the impact of the boiling level on the heat transfer coefficients at the heated wall, (2) Particle Tracking Velocimetry (PTV) is used to analyze the influence that boiling parameters have on the liquid phase turbulence statistics, (3) High-speed shadowgraphy with LED illumination is used to obtain the gas phase dynamics. To account

  1. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  2. Direct evaluation of fault trees using object-oriented programming techniques

    Science.gov (United States)

    Patterson-Hine, F. A.; Koen, B. V.

    1989-01-01

    Object-oriented programming techniques are used in an algorithm for the direct evaluation of fault trees. The algorithm combines a simple bottom-up procedure for trees without repeated events with a top-down recursive procedure for trees with repeated events. The object-oriented approach results in a dynamic modularization of the tree at each step in the reduction process. The algorithm reduces the number of recursive calls required to solve trees with repeated events and calculates intermediate results as well as the solution of the top event. The intermediate results can be reused if part of the tree is modified. An example is presented in which the results of the algorithm implemented with conventional techniques are compared to those of the object-oriented approach.

  3. Prospective, Double-Blind Evaluation of Umbilicoplasty Techniques Using Conventional and Crowdsourcing Methods

    NARCIS (Netherlands)

    Veldhuisen, C.L. Van; Kamali, P.; Wu, W.; Becherer, B.E.; Sinno, H.H.; Ashraf, A.A.; Ibrahim, A.M.S.; Tobias, A.; Lee, B.T.; Lin, S.J.

    2017-01-01

    BACKGROUND: Umbilical reconstruction is an important component of deep inferior epigastric perforator (DIEP) flap breast reconstruction. This study evaluated the aesthetics of three different umbilical reconstruction techniques during DIEP flap breast reconstruction. METHODS: From January to April

  4. Experimental evaluation of improved dual temperature hydrogen isotopic exchange reaction system

    International Nuclear Information System (INIS)

    Asakura, Yamato; Uchida, Shunsuke

    1984-01-01

    A proposed dual temperature hydrogen isotopic exchange reaction system between water and hydrogen gas is evaluated experimentally. The proposed system is composed of low temperature co-current reactors for reaction between water mists and hydrogen gas and high temperature co-current reactors for reaction between water vapor and hydrogen gas. Thus, operation is possible under atmospheric pressure with high reaction efficiency. Using the pilot test system which is composed of ten low temperature (30 0 C) reaction units and ten high temperature (200 0 C) reaction units, an experimental separation of deuterium from light water is carried out. The enrichment factor under steady state conditions, its dependency on operating time, and the reaction period necessary to obtain the steady state enrichment factor are determined experimentally and compared with calculations. It is shown that separation ability in a multistage reaction system can be estimated by numerical calculation using actual reaction efficiency in a unit reactor. (author)

  5. A practical guide to experimental geometrical optics

    CERN Document Server

    Garbovskiy, Yuriy A

    2017-01-01

    A concise, yet deep introduction to experimental, geometrical optics, this book begins with fundamental concepts and then develops the practical skills and research techniques routinely used in modern laboratories. Suitable for students, researchers and optical engineers, this accessible text teaches readers how to build their own optical laboratory and to design and perform optical experiments. It uses a hands-on approach which fills a gap between theory-based textbooks and laboratory manuals, allowing the reader to develop their practical skills in this interdisciplinary field, and also explores the ways in which this knowledge can be applied to the design and production of commercial optical devices. Including supplementary online resources to help readers track and evaluate their experimental results, this text is the ideal companion for anyone with a practical interest in experimental geometrical optics.

  6. Evaluation of revegetation techniques of a saline flue gas desulfurization sludge pond

    Energy Technology Data Exchange (ETDEWEB)

    Salo, L.F.; Artiola, J.F.; Goodrich-Mahoney, J.W. [University of Arizona, Tucson, AZ (United States). Renewable National Resources

    1999-01-01

    Codisposal of flue gas desulfurization (FGD) sludge with low-volume generating station waste simplifies disposal but creates a saline, high boron (B) waste that may be difficult to revegetate after site closure. Studies on a delta of waste material in a codisposal pond at the coal-fired Coronado Generating Station in eastern Arizona evaluated management techniques, amendments, and plants for revegetating this material. One study investigated leaching and ridging techniques and a second evaluated amendment with manure, wood shavings, and fly ash, Four salt-tolerant grass species and four saltbushes (A triplex spp,) were evaluated in the two studies. Criteria for success were high survival rates and growth, as measured by grass height and shrub height x width. Leaching salts and B from the waste was not necessary for establishment and growth of transplanted shrubs and grasses. Ridging was not a successful technique, due to limited moisture and high levels of salinity and B on these structures. Gardner saltbush (A, gardneri (Moq.) D, Dietr.) and a fourwing saltbush (A. canescens (Pursh) Nutt,) accession from the site were the most successful shrubs and alkali sactonn (Sporobolus airoides (Torr,) Torr. `Saltalk`) was the most successful grass at this disposal pond. Amendment with manure, wood shavings, or fly ash did not increase plant survival. Growth of grasses was improved with all amendments and was greatest with manure, but growth of shrubs was not improved with any amendment. 33 refs., 8 tabs.

  7. New evaluation methods for conceptual design selection using computational intelligence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Hong Zhong; Liu, Yu; Li, Yanfeng; Wang, Zhonglai [University of Electronic Science and Technology of China, Chengdu (China); Xue, Lihua [Higher Education Press, Beijing (China)

    2013-03-15

    The conceptual design selection, which aims at choosing the best or most desirable design scheme among several candidates for the subsequent detailed design stage, oftentimes requires a set of tools to conduct design evaluation. Using computational intelligence techniques, such as fuzzy logic, neural network, genetic algorithm, and physical programming, several design evaluation methods are put forth in this paper to realize the conceptual design selection under different scenarios. Depending on whether an evaluation criterion can be quantified or not, the linear physical programming (LPP) model and the RAOGA-based fuzzy neural network (FNN) model can be utilized to evaluate design alternatives in conceptual design stage. Furthermore, on the basis of Vanegas and Labib's work, a multi-level conceptual design evaluation model based on the new fuzzy weighted average (NFWA) and the fuzzy compromise decision-making method is developed to solve the design evaluation problem consisting of many hierarchical criteria. The effectiveness of the proposed methods is demonstrated via several illustrative examples.

  8. New evaluation methods for conceptual design selection using computational intelligence techniques

    International Nuclear Information System (INIS)

    Huang, Hong Zhong; Liu, Yu; Li, Yanfeng; Wang, Zhonglai; Xue, Lihua

    2013-01-01

    The conceptual design selection, which aims at choosing the best or most desirable design scheme among several candidates for the subsequent detailed design stage, oftentimes requires a set of tools to conduct design evaluation. Using computational intelligence techniques, such as fuzzy logic, neural network, genetic algorithm, and physical programming, several design evaluation methods are put forth in this paper to realize the conceptual design selection under different scenarios. Depending on whether an evaluation criterion can be quantified or not, the linear physical programming (LPP) model and the RAOGA-based fuzzy neural network (FNN) model can be utilized to evaluate design alternatives in conceptual design stage. Furthermore, on the basis of Vanegas and Labib's work, a multi-level conceptual design evaluation model based on the new fuzzy weighted average (NFWA) and the fuzzy compromise decision-making method is developed to solve the design evaluation problem consisting of many hierarchical criteria. The effectiveness of the proposed methods is demonstrated via several illustrative examples.

  9. Experimental approaches and applications

    CERN Document Server

    Crasemann, Bernd

    1975-01-01

    Atomic Inner-Shell Processes, Volume II: Experimental Approaches and Applications focuses on the physics of atomic inner shells, with emphasis on experimental aspects including the use of radioactive atoms for studies of atomic transition probabilities. Surveys of modern techniques of electron and photon spectrometry are also presented, and selected practical applications of inner-shell processes are outlined. Comprised of six chapters, this volume begins with an overview of the general principles underlying the experimental techniques that make use of radioactive isotopes for inner-sh

  10. Techniques for data compression in experimental nuclear physics problems

    International Nuclear Information System (INIS)

    Byalko, A.A.; Volkov, N.G.; Tsupko-Sitnikov, V.M.

    1984-01-01

    Techniques and ways for data compression during physical experiments are estimated. Data compression algorithms are divided into three groups: the first one includes the algorithms based on coding and which posses only average indexes by data files, the second group includes algorithms with data processing elements, the third one - algorithms for converted data storage. The greatest promise for the techniques connected with data conversion is concluded. The techniques possess high indexes for compression efficiency and for fast response, permit to store information close to the source one

  11. Experimental technique of small angle neutron scattering

    International Nuclear Information System (INIS)

    Xia Qingzhong; Chen Bo

    2006-03-01

    The main parts of Small Angle Neutron Scattering (SANS) spectrometer, and their function and different parameters are introduced from experimental aspect. Detailed information is also introduced for SANS spectrometer 'Membrana-2'. Based on practical experiments, the fundamental requirements and working condition for SANS experiments, including sample preparation, detector calibration, standard sample selection and data preliminary process are described. (authors)

  12. Experimental Object-Oriented Modelling

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius

    through, e.g., technical prototyping and active user involvement. We introduce and examine “experimental object-oriented modelling” as the intersection of these practices. The contributions of this thesis are expected to be within three perspectives on models and modelling in experimental system...... development: Grounding We develop an empirically based conceptualization of modelling and use of models in system development projects characterized by a high degree of uncertainty in requirements and point to implications for tools and techniques for modelling in such a setting. Techniques We introduce......This thesis examines object-oriented modelling in experimental system development. Object-oriented modelling aims at representing concepts and phenomena of a problem domain in terms of classes and objects. Experimental system development seeks active experimentation in a system development project...

  13. Experimental evaluation of the fretting fatigue behavior of high-strength steel monostrands

    DEFF Research Database (Denmark)

    Winkler, Jan; Fischer, Gregor; Georgakis, Christos T.

    2013-01-01

    In this paper, the fretting fatigue behavior of pretensioned high-strength steel monostrands is investigated. A method based on the digital image correlation (DIC) technique was used to quantify the relative movement between individual wires along the length of the monostrand. The experimental data....... Moreover, the paper provides relevant information about the monostrand bending stiffness and the extent of relative displacement between core and outer wires of the monostrand undergoing flexural deformations. The results presented herein are of special interest for the fatigue analysis of modern stay...

  14. Towards the synthesis of an experimental bioactive dental ceramic. Part I: Crystallinity characterization and bioactive behavior evaluation

    International Nuclear Information System (INIS)

    Goudouri, O.-M.; Kontonasaki, E.; Papadopoulou, L.; Kantiranis, N.; Lazaridis, N.K.; Chrissafis, K.; Chatzistavrou, X.; Koidis, P.; Paraskevopoulos, K.M.

    2014-01-01

    An attachment between the dental ceramic and the surrounding marginal tissues in fixed prosthetic restorations could eliminate secondary carries prevalence. The development of dental ceramics with apatite forming ability could provide the biological surface required for selective spread and attachment of specific cell types able to promote tissue attachment. Dental ceramics/bioactive glass composites synthesized by the sol gel method have been previously reported to develop carbonated hydroxyapatite (HCAp) in biomimetic solutions, requiring though a high amount of bioactive glass, which resulted in the compromise of their mechanical integrity. Thus, the aim of the present work was the synthesis and characterization of an experimental sol–gel derived dental ceramic with low amount of bioactive glass and the evaluation of its in vitro bioactivity. Differential thermal and thermogravimetric analysis (TG–DTA), Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffractometry (XRD), Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) were used to evaluate the crystal structure and the in vitro apatite forming ability of the synthesized material. The results of this study indicated the successful sol–gel synthesis of an experimental dental ceramic containing low amount of bioactive glass that presented similar structural and morphological characteristics with a commercial feldspathic dental ceramic, while exhibiting in vitro bioactivity. The apatite forming ability of the experimental sol–gel derived feldspathic dental ceramic may trigger the appropriate cellular mechanisms towards the establishment of attachment with the surrounding connective tissue. This attachment could provide a barrier to oral bacteria penetration, prolonging the life expectation of the restorations. - Highlights: • Synthesis of a bioactive sol–gel dental ceramic for fixed prosthetic restorations. • The sol–gel technique promoted the crystallization of

  15. Towards the synthesis of an experimental bioactive dental ceramic. Part I: Crystallinity characterization and bioactive behavior evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Goudouri, O.-M. [Physics Department, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kontonasaki, E. [School of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Papadopoulou, L.; Kantiranis, N. [Department of Geology, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Lazaridis, N.K. [Chemistry Department, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Chrissafis, K.; Chatzistavrou, X. [Physics Department, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Koidis, P. [School of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Paraskevopoulos, K.M., E-mail: kpar@auth.gr [Physics Department, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2014-05-01

    An attachment between the dental ceramic and the surrounding marginal tissues in fixed prosthetic restorations could eliminate secondary carries prevalence. The development of dental ceramics with apatite forming ability could provide the biological surface required for selective spread and attachment of specific cell types able to promote tissue attachment. Dental ceramics/bioactive glass composites synthesized by the sol gel method have been previously reported to develop carbonated hydroxyapatite (HCAp) in biomimetic solutions, requiring though a high amount of bioactive glass, which resulted in the compromise of their mechanical integrity. Thus, the aim of the present work was the synthesis and characterization of an experimental sol–gel derived dental ceramic with low amount of bioactive glass and the evaluation of its in vitro bioactivity. Differential thermal and thermogravimetric analysis (TG–DTA), Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffractometry (XRD), Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) were used to evaluate the crystal structure and the in vitro apatite forming ability of the synthesized material. The results of this study indicated the successful sol–gel synthesis of an experimental dental ceramic containing low amount of bioactive glass that presented similar structural and morphological characteristics with a commercial feldspathic dental ceramic, while exhibiting in vitro bioactivity. The apatite forming ability of the experimental sol–gel derived feldspathic dental ceramic may trigger the appropriate cellular mechanisms towards the establishment of attachment with the surrounding connective tissue. This attachment could provide a barrier to oral bacteria penetration, prolonging the life expectation of the restorations. - Highlights: • Synthesis of a bioactive sol–gel dental ceramic for fixed prosthetic restorations. • The sol–gel technique promoted the crystallization of

  16. Experimental evaluation of human-system interaction on alarm design

    International Nuclear Information System (INIS)

    Huang, F.-H.; Lee, Y.-L.; Hwang, S.-L.; Yenn, T.-C.; Yu, Y.-C.; Hsu, C.-C.; Huang, H.-W.

    2007-01-01

    This study evaluates the practicability of automatic reset alarm system in Fourth Nuclear Power Plant (FNPP) of Taiwan. The features of auto-reset alarm system include dynamic prioritization of all alarm signals and fast system reset. Two experiments were conducted to evaluate the effect of automatic/manual reset on operation time, situational awareness (SA), task load index (TLX), and subjective ratings. All participants, including Experts and Novices, took part in the experiment on the alarm system simulator with Load Rejection procedure. The experimental results imply that the auto-reset alarm system may be applied in an advanced control room under Load Rejection procedure, because all participants' operation time were reduced as well as Novice's SA were raised up. Nevertheless, to ensure operating safety in FNPP, the effects of the auto-reset alarm system in other procedures/special situations still need to be tested in the near future

  17. Evaluation of the Weldability in Spot Welding using Ultrasonic Technique

    International Nuclear Information System (INIS)

    Hong, Min Sung; Kim, No Hyu

    2005-01-01

    Spot welding is the most widely used in automotive and aerospace industries. The quality of weld depends upon the size of nugget between the overlapped steel plates. Recently, the thickness of the steel plates is much thinner and hence, it introduces the smaller size of nugget. Therefore, it is necessary not only to develop the criterion to evaluate the quality of weld but also to obtain the optimal welding conditions for the better performance. In this paper, the steel plates, 0.5 mm through 1.5 mm thickness, have been spot welded at different welding conditions and the nugget sizes are examined by ultrasonic technique (C-scan type). The relationships between the nugget sizes and the weldability have been investigated. The result of ultrasonic technique shows the good agreement with that of the tensile test

  18. Evaluation of the Weldability in Spot Welding using Ultrasonic Technique

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Min Sung [Ajou University, Suwon (Korea, Republic of); Kim, No Hyu [Korea University of Technology and Education, Cheonan (Korea, Republic of)

    2005-06-15

    Spot welding is the most widely used in automotive and aerospace industries. The quality of weld depends upon the size of nugget between the overlapped steel plates. Recently, the thickness of the steel plates is much thinner and hence, it introduces the smaller size of nugget. Therefore, it is necessary not only to develop the criterion to evaluate the quality of weld but also to obtain the optimal welding conditions for the better performance. In this paper, the steel plates, 0.5 mm through 1.5 mm thickness, have been spot welded at different welding conditions and the nugget sizes are examined by ultrasonic technique (C-scan type). The relationships between the nugget sizes and the weldability have been investigated. The result of ultrasonic technique shows the good agreement with that of the tensile test

  19. Evaluation of corrosion of prestressing steel in concrete using non-destructive techniques

    International Nuclear Information System (INIS)

    Ali, M.G.; Maddocks, A.R.

    2003-01-01

    Use of high strength steel in pre-stressed concrete structures has been in use in Australia for many decades. Highway bridges, among other structures, have extensively used pre-stress-ing and post-tensioning techniques. Although prestressing offers many competitive edges to it's traditional rival reinforced concrete, the consequence of damage to prestressing tendons could be catastrophic. Periodic visual inspections of prestressed concrete bridges throughout the world have demonstrated the growing problem of deterioration of prestressing steel as a result of corrosion. Early detection of damage to prestressing steel therefore is of paramount importance. Unfortunately no reliable and practical non-destructive evaluation technique has been available for assessing the condition of prestressing steel within concrete although a number of techniques appear promising. The following inspection methods have been highlighted in recent literature for their use as non-destructive inspection methods for prestressed concrete structures. In addition to the techniques discussed, a number of destructive, or invasive techniques also exist for determination of the corrosion status of prestressing tendons in prestressed structures. The following non-destructive techniques are discussed in some detail: Radiography; Computed Tomography; Surface Penetrating Radar; Impact Echo; Acoustic Emission Monitoring; Magnetic Field Disturbance Technique; Remnant Magnetism Method; Linear Polarisation Method; Electrical Resistance and Surface Potential Survey. The portability, limitations and use in Australia of these techniques are summarised in a table

  20. Experimental Performance Evaluation of a High Speed Permanent Magnet Synchronous Motor and Drive for a Flywheel Application at Different Frequencies

    Science.gov (United States)

    Nagorny, Aleksandr S.; Jansen, Ralph H.; Kankam, M. David

    2007-01-01

    This paper presents the results of an experimental performance characterization study of a high speed, permanent magnet motor/generator (M/G) and drive applied to a flywheel module. Unlike the conventional electric machine the flywheel M/G is not a separated unit; its stator and rotor are integrated into a flywheel assembly. The M/G rotor is mounted on a flywheel rotor, which is magnetically levitated and sealed within a vacuum chamber during the operation. Thus, it is not possible to test the M/G using direct load measurements with a dynamometer and torque transducer. Accordingly, a new in-situ testing method had to be developed. The paper describes a new flywheel M/G and drive performance evaluation technique, which allows the estimation of the losses, efficiency and power quality of the flywheel high speed permanent magnet M/G, while working in vacuum, over wide frequency and torque ranges. This method does not require any hardware modification nor any special addition to the test rig. This new measurement technique is useful for high-speed applications, when applying an external load is technically difficult.

  1. Evaluation of ECC bypass data with a nonlinear constrained MLE technique

    International Nuclear Information System (INIS)

    Bishop, T.A.; Collier, R.P.; Kurth, R.E.

    1980-01-01

    Recently, Battelle's Columbus Laboratories have been involved in scale-model tests of emergency core cooling (ECC) systems for hypothesized loss-of-coolant accidents in pressurized water reactors (PWR). These tests are intended to increase our understanding of ECC bypass, which can occur when steam flow from the reactor core causes the emergency coolant to bypass the core and flow directly to the break. One objective of these experiments is the development of a correlation which relates the flow rate of water penetrating to the core to the steam flow rate. This correlation is derived from data obtained from a 2/15 scale model PWR at various ECC water injection rates, subcoolings, pressures, and steam flows. The general form of the correlation being studied is a modification of the correlation first proposed by Wallis. The correlation model is inherently nonlinear and implicit in form, and the model variables are all subject to error. Therefore, the usual nonlinear analysis techniques are inappropriate. A nonlinear constrained maximum-likelihood-estimation technique has been used to obtain estimates of the model parameters, and a Battelle-developed code, NLINMLE, has been used to analyze the data. The application of this technique is illustrated by sample calculations of estimates of the model parameters and their associated confidence intervals for selected experimental data sets. 5 figures, 7 tables

  2. Application gives the technique the analytic tree in the evaluation the effectiveness programs to radiological protection

    International Nuclear Information System (INIS)

    Perez Gonzalez, F.; Perez Velazquez, R.S.; Fornet Rodriguez, O.; Mustelier Hechevarria, A.; Miller Clemente, A.

    1998-01-01

    In the work we develop the IAEA recommendations in the application the analytic tree as instrument for the evaluation the effectiveness the occupational radiological protection programs. Is reflected like it has been assimilated and converted that technique in daily work istruments in the evaluation process the security conditions in the institutions that apply the nuclear techniques with a view to its autorization on the part of the regulatory organ

  3. A review of residual stress analysis using thermoelastic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S [University of Southampton, School of Engineering Sciences, Highfield, Southampton, SO17 1BJ (United Kingdom); Burguete, R L [Airbus UK Ltd., New Filton House, Filton, Bristol, BS99 7AR (United Kingdom)

    2009-08-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  4. A review of residual stress analysis using thermoelastic techniques

    International Nuclear Information System (INIS)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S; Burguete, R L

    2009-01-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  5. Theoretical and experimental evaluation of an indirect-fired GAX cycle cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, V.H.; Vidal, A. [Posgrado en Ingenieria, Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco S/N, Apdo. Postal 34, 62580 Temixco Morelos (Mexico); Best, R.; Garcia-Valladares, O. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco S/N, Apdo. Postal 34, 62580 Temixco Morelos (Mexico); Velazquez, N. [Instituto de Ingenieria, Universidad Autonoma de Baja California, Calle de la Normal S/N, Insurgentes Este, 21280 Mexicali, BC (Mexico)

    2008-06-15

    A theoretical and experimental evaluation of an indirect-fired GAX-Prototype Cooling System (GAX-PCS), using ammonia-water as the working fluid, is presented. The GAX-PCS was designed for a cooling capacity of 10.6 kW (3 tons). A simulation model was developed, calibrated and validated with experimental values in order to predict the performance of the system outside the design parameters. Experimental results were obtained using thermal oil, at temperatures from 180 to 195 C, as heating source. An internal heat recovery in the system of {proportional_to}55% with respect to the total heat supplied in the generator was obtained. Also the performance of the GAX absorption system, integrated to a micro gas turbine (MGT) as a cogeneration system was simulated. Overall efficiencies for the cogeneration system from 29% to 49% were obtained for cooling loads from 5 kW to 20 kW, respectively. With the theoretical and experimental study of the proposed cycle, it is concluded that the GAX-PCS presents potential to compete technically in the Mexican air conditioning market. (author)

  6. Uncertainty evaluation for three-dimensional scanning electron microscope reconstructions based on the stereo-pair technique

    DEFF Research Database (Denmark)

    Carli, Lorenzo; Genta, G; Cantatore, Angela

    2011-01-01

    3D-SEM is a method, based on the stereophotogrammetry technique, which obtains three-dimensional topographic reconstructions starting typically from two SEM images, called the stereo-pair. In this work, a theoretical uncertainty evaluation of the stereo-pair technique, according to GUM (Guide to ...

  7. Design techniques and measured performance for a uniformly-pumped 4-cm diameter rod amplifier

    International Nuclear Information System (INIS)

    Linford, G.J.; Yarema, S.M.

    1976-01-01

    A solid-state laser rod amplifier of moderate aperture achieving a high degree of spatial gain uniformity has been constructed and its performance evaluated. Digital and analogue techniques were used to optimize the amplifier design for performance in a laser fusion application. Results of simple 2-D computer simulations and experimental evaluations of amplifier performance are presented

  8. Evaluating psychological interventions in a novel experimental human model of anxiety

    Science.gov (United States)

    Ainsworth, Ben; Marshall, Jemma E.; Meron, Daniel; Baldwin, David S.; Chadwick, Paul; Munafò, Marcus R.; Garner, Matthew

    2015-01-01

    Inhalation of 7.5% carbon dioxide increases anxiety and autonomic arousal and provides a novel experimental model of anxiety with which to evaluate pharmacological and psychological treatments for anxiety. To date several psychotropic drugs including benzodiazepines, SSRIs and SNRIs have been evaluated using the 7.5% CO2 model; however, it has yet to be used to evaluate psychological interventions. We compared the effects of two core psychological components of mindfulness-meditation (open monitoring and focused attention) against general relaxation, on subjective, autonomic and neuropsychological outcomes in the 7.5% CO2 experimental model. 32 healthy screened adults were randomized to complete 10 min of guided open monitoring, focused attention or relaxation, immediately before inhaling 7.5% CO2 for 20 min. During CO2-challenge participants completed an eye-tracking measure of attention control and selective attention. Measures of subjective anxiety, blood pressure and heart rate were taken at baseline and immediately following intervention and CO2-challenge. OM and FA practice reduced subjective feelings of anxiety during 20-min inhalation of 7.5% CO2 compared to relaxation control. OM practice produced a strong anxiolytic effect, whereas the effect of FA was more modest. Anxiolytic OM and FA effects occurred in the absence of group differences in autonomic arousal and eye-movement measures of attention. Our findings are consistent with neuropsychological models of mindfulness-meditation that propose OM and FA activate prefrontal mechanisms that support emotion regulation during periods of anxiety and physiological hyper-arousal. Our findings complement those from pharmacological treatment studies, further supporting the use of CO2 challenge to evaluate future therapeutic interventions for anxiety. PMID:25765144

  9. The Impact of the Immediate Feedback Assessment Technique on Course Evaluations

    Directory of Open Access Journals (Sweden)

    Trent W. Maurer

    2015-09-01

    Full Text Available This project reports the results of two studies that investigated the impact on course evaluations of using partial credit iterative responding (PCIR with the Immediate Feedback Assessment Technique (IF-AT forms on summative course assessments. This project also quantifies grade inflation from utilizing different PCIR schemes and documents the percentage of possible partial credit students learned. Study 1 compared evaluations in courses where exams were manipulated. Study 2 compared evaluations in courses where daily reading quizzes were manipulated. Results from Study 1 revealed that multiple course evaluation scores increased 10% in the PCIR condition. Students earned 75% of the partial credit available through PCIR, which resulted in a 10% increase in their exam scores. Results from Study 2 revealed no difference in course evaluations between conditions. Students earned roughly 40% of the partial credit available through PCIR, resulting in a 4 to 8% increase in their quiz scores, depending on the PCIR scheme.

  10. An Experimental Analysis of the Relation between Assigned Grades and Instructor Evaluations

    Science.gov (United States)

    Smith, Dale L.; Cook, Patrick; Buskist, William

    2011-01-01

    The perceived relation between assigned student grades and instructor evaluations of teaching has been the subject of much debate, though few laboratory studies have been conducted with adequate controls. Marsh and Roche suggested that experimental field studies may be a particularly promising avenue for further analyses of this relation. The…

  11. Experimental Research on Quick Structural Health Monitoring Technique for Bridges Using Smartphone

    Directory of Open Access Journals (Sweden)

    Xuefeng Zhao

    2016-01-01

    Full Text Available In the recent years, with the development and popularization of smartphone, the utilization of smartphone in the Structural Health Monitoring (SHM has attracted increasing attention owing to its unique feature. Since bridges are of great importance to society and economy, bridge health monitoring has very practical significance during its service life. Furthermore, rapid damage assessment of bridge after an extreme event such as earthquake is very important in the recovery work. Smartphone-based bridge health monitoring and postevent damage evaluation have advantages over the conventional monitoring techniques, such as low cost, ease of installation, and convenience. Therefore, this study investigates the implementation feasibility of the quick bridge health monitoring technique using smartphone. A novel vision-based cable force measurement method using smartphone camera is proposed, and, then, its feasibility and practicality is initially validated through cable model test. An experiment regarding multiple parameters monitoring of one bridge scale model is carried out. Parameters, such as acceleration, displacement, and angle, are monitored using smartphone. The experiment results show that there is a good agreement between the reference sensor and smartphone measurements in both time and frequency domains.

  12. Periodontal evaluation of different toothbrushing techniques in patients with fixed orthodontic appliances

    Directory of Open Access Journals (Sweden)

    Patricia Oehlmeyer Nassar

    2013-02-01

    Full Text Available INTRODUCTION: Plaque control is the major consensus during orthodontic treatment to prevent the occurrence of cavities and periodontal inflammation. The mechanic resource of greater effectiveness and frequent use in this control is the oral hygiene. The tooth brushing techniques most used in orthodontic patients are: Ramfjord's method, Modified Stillman technique and Bass method. OBJECTIVE: Since control studies evaluating the effectiveness of usual tooth brushing techniques do not show clear advantage, the objective of this study was to evaluate the effectiveness of three brushing methods, through periodontal clinical parameters of patients with fixed orthodontic appliances. METHODS: Thirty patients were selected, with ages between 14 and 22 years old, with fixed orthodontic appliances. After basic periodontal treatment the following factors were evaluated: 1 - Plaque index and 2 - Gingival index and each patient was randomly included in one of the three selected groups according to the brushing technique: Group 1 - Scrubbing technique; Group 2 - Modified Stillman technique and Group 3 - Bass technique. Patients were evaluated for 9 months. RESULTS: The results showed a significant reduction of clinical parameters by the end of this period, however there was a very significant reduction of Gingival index on group 3 (13.6% when compared to the other groups. CONCLUSION: Thus, it can be suggested that the Bass technique can be effective on the reduction of periodontal clinical parameters of Plaque index and Gingival index in patients with fixed orthodontic appliances.INTRODUÇÃO: o controle de placa bacteriana é o maior consenso durante o tratamento ortodôntico para prevenir a ocorrência de cáries e inflamação periodontal. O recurso mecânico de maior efetividade e uso frequente nesse controle é a higienização bucal. As técnicas de escovação dentária mais usadas por pacientes ortodônticos são: a friccional giratória de Ramfjord, a

  13. CISM-Course on Modern Optical Methods in Experimental Solid Mechanics

    CERN Document Server

    2000-01-01

    The book covers the theories and physics of advanced new optical measuring methods and problems of experimental performance, recent achievements in the basic interferometric methods holography, speckle-interferometry, shearography as well as linear/non-linear photoelasticity and photoviscoelasticity, Moiré- and grid-techniques. It deals with theory and application of digital image processing, methods of data recording, data processing and -visualisation, with mathematical/numerical procedures for final evaluation of digitised measured data and the principle of hybrid techniques. It introduces into the new perceptions of methods in experimental solid mechanics and it should encourage scientists to deal intensively with the theories for further developments, and enables practitioners, to understand theory and physics of the new achievements at least and to apply the methods in research als well as in developments in practice.

  14. Comparisons of experimental beta-ray spectra important to decay heat predictions with ENSDF [Evaluated Nuclear Structure Data File] evaluations

    International Nuclear Information System (INIS)

    Dickens, J.K.

    1990-03-01

    Graphical comparisons of recently obtained experimental beta-ray spectra with predicted beta-ray spectra based on the Evaluated Nuclear Structure Data File are exhibited for 77 fission products having masses 79--99 and 130--146 and lifetimes between 0.17 and 23650 sec. The comparisons range from very poor to excellent. For beta decay of 47 nuclides, estimates are made of ground-state transition intensities. For 14 cases the value in ENSDF gives results in very good agreement with the experimental data. 12 refs., 77 figs., 1 tab

  15. Development of spent solvent treatment process by a submerged combustion technique

    International Nuclear Information System (INIS)

    Uchiyama, Gunzo; Maeda, Mitsuru; Fujine, Sachio; Amakawa, Masayuki; Uchida, Katsuhide; Chida, Mitsuhisa

    1994-01-01

    An experimental study using a bench-scale equipment of 1 kg-simulated spent solvents per hour has been conducted in order to evaluate the applicability of a submerged combustion technique to the treatment of spent solvents contaminated with TRU elements. This report describes the experimental results on the combustion characteristics of the simulated spent solvents of tri-n-butyl phosphate and/or n-dodecane, and on the distribution behaviors of combustion products such as phosphoric acid, Ru, I, Zr and lanthanides as TRU simulants in the submerged combustion process. Also the experimental results of TRU separation from phosphoric acid solution by co-precipitation using bismuth phosphate are reported. It was shown that the submerged combustion technique was applicable to the treatment of spent solvents including the distillation residues of the solvent. Based on the experimental data, a new treatment process of spent solvent was proposed which consisted of submerged combustion, co-precipitation using bismuth phosphate, ceramic membrane filtration, cementation of TRU lean phosphate, and vitrification of TRU rich waste. (author)

  16. Tribological evaluation for experimental design Al{sub 2}O{sub 3} obtained via low pressure injection moulding (LPIM); Avaliacao tribologica por planejamento experimental da Al{sub 2}O{sub 3} obtida via moldagem por injecao em baixa pressao (MIBP)

    Energy Technology Data Exchange (ETDEWEB)

    Dotta, A.L.B.; Costa, C.A.; Farias, M.C.M. [Universidade de Caxias do Sul (UCS), RS (Brazil); Cunha, M.A da, E-mail: alinebandotta@gmail.com [Universidade Federal do Rio Grande do Sul (UFRGS), Caxias do Sul, RS (Brazil)

    2016-07-01

    This work represents the tribological study of Al{sub 2}O{sub 3} obtained by LPIM using the experimental design technique to evaluate the interaction of the tribological parameters with the friction and wear. The LPIM process was performed at 90 °C for 24 h. The average friction coefficient for the factorial experimental design varied significantly with the load and the speed when Al{sub 2}O{sub 3} was tested with the steel counter body. In general, the wear coefficient was lower for the tribological pair Al{sub 2}O{sub 3}-steel, in which occurred the formation of an iron oxide tribofilm on the surface. As for the Al{sub 2}O{sub 3}-Al{sub 2}O{sub 3} pair, an intergranular fracture of the surface occurred, in addition to the presence of material adhered on the tracks. (author)

  17. Development and evaluation of analytical techniques for total chlorine in used oils and oil fuels

    International Nuclear Information System (INIS)

    Gaskill, A. Jr.; Estes, E.D.; Hardison, D.L.; Friedman, P.H.

    1990-01-01

    A current EPA regulation prohibits the sale for burning in nonindustrial boilers of used oils and oil fuels. This paper discusses how analytical techniques for determining total chlorine were evaluated to provide regulatory agencies and the regulated community with appropriate chlorine test methods. The techniques evaluated included oxygen bomb combustion followed by chemical titration or ion chromatography, instrumental microcoulometry, field test kits, and instrumental furnace/specific ion electrode determinator, a device based on the Beilstein reaction, and x-ray fluorescence spectrometry. These techniques were subjected to interlaboratory testing to estimate their precision, accuracy, and sensitivity. Virgin and used crankcase oils, hydraulic and metalworking oils, oil fuels and oil fuel blends with used oils were tested. The bomb techniques, one of the test kits, microcoulometry and all but one x-ray analyzer were found to be suitable for this application. The chlorine furnace and the Beilstein device were found to be inapplicable at the levels of interest

  18. Opto-acoustic technique to evaluate adhesion strength of thin-film systems

    Directory of Open Access Journals (Sweden)

    S. Yoshida

    2012-06-01

    Full Text Available An opto-acoustic technique is proposed to evaluate the adhesion strength of thin film systems at the film-substrate interface. The thin-film system to be examined is configured as an end-mirror of a Michelson interferometer, and driven from the rear with an acoustic transducer at audible frequencies. The amplitude of the resultant oscillation of the film is quantified as the variation in the contrast of the interferometric fringe pattern observed with a digital camera at 30 frames/s. As a proof of concept, experiment has been conducted with the use of a pair of strongly and weakly adhered Au-coated Si-wafer specimens. The technique successfully differentiates the adhesion strength of the specimens.

  19. Supporting the potential of quantitative ultrasonic techniques for the evaluation of platelet concentration

    Science.gov (United States)

    Villamarín, J. A.; Jiménez, Y. M.; Molano, L. Tatiana; Gutierrez, W. Edgar; Londoño, L. Fernando; Gutierrez, D. A.

    2017-11-01

    This article describes the results obtained by making use of a non-destructive, non-invasive ultrasonic system for the acoustic characterization of bovine plasma rich in platelets using digital signal processing techniques. This study includes computational methods based on acoustic spectrometry estimation and experimental measurements of the speed of sound in blood plasma from different samples analyzed, using an ultrasonic field with resonance frequency of 5 MHz. The results showed that the measurements on ultrasonic signals can contribute to the hematological predictions based on the linear regression model applied to the relationship between experimental ultrasonic parameters calculated and platelet concentration, indicating a growth rate of 1 m/s for each 0.90 x103 platelet per mm3. On the other hand, the attenuation coefficient presented changes of 20% in the platelet concentration using a resolution of 0.057 dB/cm MHz.

  20. An evaluation of children's metered-dose inhaler technique for asthma medications.

    Science.gov (United States)

    Burkhart, Patricia V; Rayens, Mary Kay; Bowman, Roxanne K

    2005-03-01

    , such as those provided in this article, should be given to patients for home use and for use by clinicians to evaluate patient technique at each health encounter.

  1. Development and experimental basis of local subretinal technique of xenogenic’s injection stem cells labelled by magnetic perticles

    Directory of Open Access Journals (Sweden)

    Yu. A. Belyy

    2014-10-01

    Full Text Available Purpose: is to develop a technique for local subretinal injection of xenogeneic stem cells labeled with magnetic particles and to prove experimentally its effectiveness.Material and methods: We used a line of stem cells HEK-293 GFP,labeled with magnetic particles. The study was made on 84 eyes of 42 chinchilla rabbits 6 months of age, the weight were from 2.5 to 3.5 kg. All right eyes were experimental (42 eyes and all left eyes (42 eyes were the control group. In the experimental group we used original complex of polymer elastic magnetic implant (PEMI with laser probe and fixed it to the sclera, then we made a median vitrectomy and injected HEK-293 GFP under the retina using a specially designed dispenser. In the control group PEMI was not fixed. We examined animals using biomicroscopy, ophthalmoscopy, ultrasound scanning, optical coherence tomography  OCT, computer tomography (CT, morphological study (cryohistological sections in 1, 3, 5, 7, 14 day and 1 month after surgery.Results: According the results of biomicroscopy in observation periods up to 3 days the vascular injection was visualized in the area operation. According the results of ophthalmoscopy and ultrasound scanning in 1 day the local retinal detachment was visualized in the area of local injection of the stem cells, which was not visualized in terms of further observations. CT helped us to confirm the local place of PEMI fixation. The morphological study results showed that cells were located in the subretinal space up to 14 days in the experimental group, and only up 3 days in the control group.Conclusion: The suggested surgical technique enables to control the injection of cells into the subretinal space, reduces the risk of tissue damage and exit cells in the vitreous space. The suggested methodology allows the fixing of the cellular material in the local place of the injection and enables to predict cells`s movement.

  2. Covariance data evaluation of some experimental data for n + 65,63,NatCu

    International Nuclear Information System (INIS)

    Jia Min; Liu Jianfeng; Liu Tingjin

    2003-01-01

    The evaluation of covariance data for 65,63,Nat Cu in the energy range from 99.5 keV to 20 MeV was carried out using EXPCOV and SPC code based on the experimental data available. The data can be as a part of the covariance file 33 in the evaluated library in ENDF/B6 format for the corresponding nuclides, and also can be used as the basis of theoretical calculation concerned. (authors)

  3. Investigation of objective evaluation system of anatomical knowledge and operative techniques in education for rhinologic surgery

    International Nuclear Information System (INIS)

    Ishimasa, Hiroshi; Murata, Hideyuki

    2006-01-01

    Operative technique and approach method for the nasal and paranasal sinuses, areas of anatomical complexity and high individual variation, have been transformed dramatically in recent years with the introduction of the endoscope. However, due to surgeons' unfamiliarity with the technique and anatomical misidentification, medical errors show no sign of significant decline. As endoscopic sinus surgery (ESS) is an indirect operating procedure, conducted while watching a video monitor, it is necessary for the surgeon to become accustomed to the special properties of the endoscope, namely, the lack of perspective projection. Until now, surgical training has made repetitive use of video material and donated cadavers for skill practice, and a system of one-to-one instruction whereby instruction is received from a lead surgeon while the learner joins the actual procedure as an assistant. That is to say, there has been no objective method of evaluating individual proficiency until now. In our study, evaluation of individual anatomical knowledge and thought process until task completion, objective evaluation of surgical instrument handling and technique, and evaluation of knowledge required in actual surgeries are discussed Then an individually responsive method of surgical instruction with self-evaluation and self-cognition will be sought. (author)

  4. Experimental techniques and theoretical models for the study of integral 14 MeV neutron cross sections

    International Nuclear Information System (INIS)

    Csikai, J.

    1981-01-01

    Owing to technical reasons, most of the data for fast neutron-induced reactions were measured at 14 MeV and the free parameters in nuclear reaction models have been determined at this energy. The discrepancies between experiment and theory are often due to the unmeasured or unreliable experimental data; therefore, it is important to survey the present techniques used for the measurement of total, elastic, nonelastic and partial nonelastic [(n,xn); (n,x charged); (n,f); (n,γ)] cross sections for 14 MeV neutrons. Systematics in the data as well as theoretical and semi-empirical models are also outlined. (author)

  5. Processing ultrafine-grained Aluminum alloy using Multi-ECAP-Conform technique

    International Nuclear Information System (INIS)

    Fakhretdinova, Elvira; Raab, Georgy; Valiev, Ruslan; Ryzhikov, Oleg

    2014-01-01

    The stress-strained state (SSS), contact and force parameters of a new SPD technique – Multi-ECAP-Conform – have been studied. The new technique ensures a high level of accumulated strain □=4...5 per one processing cycle. Physical and computer modeling by finite element method in Deform-3D software was applied to evaluate the parameters. It is shown that the results of physical and computer modeling correlate with each other. Equipment has been upgraded, and experimental samples of Al-Mg-Si system alloy have been processed

  6. Development of Experimental Setup of Metal Rapid Prototyping Machine using Selective Laser Sintering Technique

    Science.gov (United States)

    Patil, S. N.; Mulay, A. V.; Ahuja, B. B.

    2018-04-01

    Unlike in the traditional manufacturing processes, additive manufacturing as rapid prototyping, allows designers to produce parts that were previously considered too complex to make economically. The shift is taking place from plastic prototype to fully functional metallic parts by direct deposition of metallic powders as produced parts can be directly used for desired purpose. This work is directed towards the development of experimental setup of metal rapid prototyping machine using selective laser sintering and studies the various parameters, which plays important role in the metal rapid prototyping using SLS technique. The machine structure in mainly divided into three main categories namely, (1) Z-movement of bed and table, (2) X-Y movement arrangement for LASER movements and (3) feeder mechanism. Z-movement of bed is controlled by using lead screw, bevel gear pair and stepper motor, which will maintain the accuracy of layer thickness. X-Y movements are controlled using timing belt and stepper motors for precise movements of LASER source. Feeder mechanism is then developed to control uniformity of layer thickness metal powder. Simultaneously, the study is carried out for selection of material. Various types of metal powders can be used for metal RP as Single metal powder, mixture of two metals powder, and combination of metal and polymer powder. Conclusion leads to use of mixture of two metals powder to minimize the problems such as, balling effect and porosity. Developed System can be validated by conducting various experiments on manufactured part to check mechanical and metallurgical properties. After studying the results of these experiments, various process parameters as LASER properties (as power, speed etc.), and material properties (as grain size and structure etc.) will be optimized. This work is mainly focused on the design and development of cost effective experimental setup of metal rapid prototyping using SLS technique which will gives the feel of

  7. Transvaginal ultrasound ovarian diathermy: sheep as an experimental model

    Directory of Open Access Journals (Sweden)

    Pimentel Anita M

    2012-01-01

    Full Text Available Abstract Background Some techniques of transvaginal ovarian drilling have been previously described. Nevertheless a monopolar transvaginal ovarian cauterization, that use the expertise and safety of transvaginal puncture for oocyte captation seems to be an easier and feasible approach. The aim of this study was to develop a minimally invasive ovarian cauterization technique under transvaginal ultrasound control, and to evaluate the safety of the transvaginal ovarian monopolar cauterization, female sheep at reproductive age were used as an experimental model. Findings An experimental study was performed in a university research center. Seventeen female sheep (15 Corriedale e 2 Suffolk in reproductive age were submitted to transvaginal ovarian cauterization with a monopolar Valleylab Force 2 electrocautery. Macroscopic and microscopic lesions were assessed. Ovarian size were 1.31 cm2 ± 0,43 (Corriedale and 3.41 cm2 ± 0,64 (Suffolk. From 30 ovaries from Corriedale sheep punctured, only 3 were cauterized, presenting macroscopic and typical microscopic lesion. In the Suffolk sheep group, only one ovary was cauterized. No lesion could be found in the needle path. Conclusions This is the first experimental animal model described for ovarian cauterization needle guided by transvaginal ultrasound. The sheep does not seem to be the ideal animal model to study this technique. Another animal model, whose ovaries are better identified by transvaginal ultrasound should be sought for this technique, theoretically less invasive, before it could be offered safely to women with polycystic ovary syndrome.

  8. Scattering recoil coincidence spectrometry: a new experimental technique for profiling hydrogen isotopes in LOW-Z thin films

    International Nuclear Information System (INIS)

    Forster, J.S.; Leslie, J.R.; Laursen, T.

    1990-01-01

    The new technique for profiling light elements in thin, self-supporting foils, which uses a coincidence measurement over very large solid angles, has been demonstrated experimentally. A beam of 2.0 MeV 4 He particles was used to bombard films of (i) cracked ethylene and (ii) evaporated carbon which was subsequently implanted with 7.5 keV 1 H + ions to a concentration of 10 17 /cm 2 . Plots of E α vs E p clearly show the 1 H distributions in the foil. (author)

  9. Evaluation of a standardised radiographic technique of the equine hoof

    International Nuclear Information System (INIS)

    Kummer, M.; Lischer, C.; Ohlerth, S.; Vargas, J.; Auer, J.

    2004-01-01

    Radiography of the equine hoof is often used to obtain a diagnosis. Quantitative interpretation, especially for research purposes requires high quality and accuracy of radiographs. The purpose of this study was to describe and evaluate a radiographic technique for the lateromedial (LM) and the dorsopalmar (DP) view of the equine hoof. Ten radiographs for each view from one cadaver limb and from both front feet in a standing horse were taken in order to assess repeatability of the radiographic technique. The method requires easy to use adjustable and portable equipment and strictly defined external radio opaque markers on the hoof capsule. The digitalised radiographs were processed and analysed with the software package Metron PXTM, measuring 13 parameters in the LM view and 10 parameters in the DP view, respectively. Results show that with few exceptions measurements of these parameters revealed a coefficient of variation that was smaller than 0.05. It was concluded that this easy to use standardised radiographic technique ensures excellent accuracy and repeatability for both the LM and DP view. Hence, this method provides an adequate tool for quantitative assessment of the equine hoof, inter- and intraindividually

  10. Mechanical Behaviour of 3D Multi-layer Braided Composites: Experimental, Numerical and Theoretical Study

    Science.gov (United States)

    Deng, Jian; Zhou, Guangming; Ji, Le; Wang, Xiaopei

    2017-12-01

    Mechanical properties and failure mechanisms of a newly designed 3D multi-layer braided composites are evaluated by experimental, numerical and theoretical studies. The microstructure of the composites is introduced. The unit cell technique is employed to address the periodic arrangement of the structure. The volume averaging method is used in theoretical solutions while FEM with reasonable periodic boundary conditions and meshing technique in numerical simulations. Experimental studies are also conducted to verify the feasibility of the proposed models. Predicted elastic properties agree well with the experimental data, indicating the feasibility of the proposed models. Numerical evaluation is more accurate than theoretical assessment. Deformations and stress distributions of the unit cell under tension shows displacement and traction continuity, guaranteeing the rationality of the applied periodic boundary conditions. Although compression and tension modulus are close, the compressive strength only reaches 70% of the tension strength. This indicates that the composites can be weakened in compressive loading. Additionally, by analysing the micrograph of fracture faces and strain-stress curves, a brittle failure mechanism is observed both in composites under tension and compression.

  11. Development and evaluation of analytical techniques for total chlorine in burner fuels

    International Nuclear Information System (INIS)

    Gaskill, A. Jr.; Estes, E.D.; Hardison, D.L.; Friedman, P.H.

    1987-01-01

    A current EPA regulation prohibits the sale for burning in non-industrial boilers of used oils and oil fuels contaminated above specified levels with certain metals and total chlorine. When burned as fuel in a small boiler, the contaminants may be emitted to the ambient air at hazardous levels. This regulation establishes a rebuttable presumption that used oil containing more than 1,000 ppm total chlorine has been mixed with halogenated solvents and is a hazardous waste. Rebutting the presumption requires the seller of the oil to prove that this chlorine is not due to halogenated solvents or other hazardous halogenated organics. If the rebuttal is successful, the oil can be sold as fuel up to a level of 4000 ppm total chlorine. Analytical techniques for determination of total chlorine were evaluated or developed to provide regulatory agencies and the regulated community with appropriate chlorine test methods. The techniques evaluated included chemical titrations following oxygen bomb combustion, disposable field test kits, instrumental microcoulometry, and x-ray fluorescence spectrometry. These candidate techniques were subjected to interlaboratory testing to estimate their precision, accuracy, sensitivity, and susceptibility to matrix effects. Information on ease of use and analysis costs was also collected. Based on this pilot study, test methods will be written for the most promising techniques and subjected to a formal collaborative study to generate precision and accuracy data for each method. These methods are to be proposed in the Federal Register as mandatory for compliance with the existing used oil regulation

  12. On development and improvement of evaluation techniques for seismic ground motion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    Issues regarding evaluation of active fault and ground motion for formulation of design basis ground motion (Ss) were prescribed in 'NSC seismic and tsunami safety reviewing manual' in 2012. Moreover, Nuclear Regulation Authority (NRA) is establishing the new seismic safety guideline. In this theme following four subjects were investigated to resolve the important problems for ground motion evaluation, (1) advanced evaluation of ground motion using fault model and uncertainty; (2) improving evaluation of ground motion using attenuation relation of response spectrum; (3) development of advanced and generic techniques for ground motion observation and observation tool in deep borehole; (4) improving the evaluation of site effect and seismic wave propagation characteristics. In addition as emergency requirements from NRA following two subjects were also investigated; (5) hazard evaluation development on fault displacement; (6) ground motion evaluation at near-by source location. Obtained results will be reflected not only in the domestic guideline established by NRA but in the national safety review and also in the safety standard guidelines of the International Atomic Energy Agency (IAEA) through its Extra-Budgetary Program (EBP), thereby contributing to technical cooperation in global nuclear seismic safety. (author)

  13. Evaluation of ultrasonic technique to characterize the concentration of boric acid in liquid medium

    International Nuclear Information System (INIS)

    Kohara, Richard Yuzo Ramida

    2015-01-01

    This dissertation is to analyze the viability of using ultrasonic technique to characterize the concentration of boric acid in liquid medium non-invasively, therefore, ultrasonic tests were performed relating different boric acid concentrations with the travel time of the ultrasonic wave, also were evaluated factors able to mask the characterization of these concentrations by ultrasonic technique. The results showed that the ultrasonic technique allows the characterization of boric acid concentrations in liquid medium in very simple terms by the ultrasonic wave travel time, requiring further studies in complex conditions. (author)

  14. Experimental Evaluation of the Free Piston Engine - Linear Alternator (FPLA)

    Energy Technology Data Exchange (ETDEWEB)

    Leick, Michael T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Moses, Ronald W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    This report describes the experimental evaluation of a prototype free piston engine - linear alternator (FPLA) system developed at Sandia National Laboratories. The opposed piston design wa developed to investigate its potential for use in hybrid electric vehicles (HEVs). The system is mechanically simple with two - stroke uniflow scavenging for gas exchange and timed port fuel injection for fuel delivery, i.e. no complex valving. Electrical power is extracted from piston motion through linear alternators wh ich also provide a means for passive piston synchronization through electromagnetic coupling. In an HEV application, this electrical power would be used to charge the batteries. The engine - alternator system was designed, assembled and operated over a 2 - year period at Sandia National Laboratories in Livermore, CA. This report primarily contains a description of the as - built system, modifications to the system to enable better performance, and experimental results from start - up, motoring, and hydrogen combus tion tests.

  15. Antioxidative Categorization of Twenty Amino Acids Based on Experimental Evaluation.

    Science.gov (United States)

    Xu, Naijin; Chen, Guanqun; Liu, Hui

    2017-11-27

    In view of the great importance bestowed on amino acids as antioxidants in oxidation resistance, we attempted two common redox titration methods in this report, including micro-potassium permanganate titration and iodometric titration, to measure the antioxidative capacity of 20 amino acids, which are the construction units of proteins in living organisms. Based on the relative intensities of the antioxidative capacity, we further conducted a quantitative comparison and found out that the product of experimental values obtained from the two methods was proven to be a better indicator for evaluating the relative antioxidative capacity of amino acids. The experimental results were largely in accordance with structural analysis made on amino acids. On the whole, the 20 amino acids concerned could be divided into two categories according to their antioxidative capacity. Seven amino acids, including tryptophan, methionine, histidine, lysine, cysteine, arginine and tyrosine, were greater in total antioxidative capacity compared with the other 13 amino acids.

  16. Experimental study of sodium droplet burning in free fall. Evaluation of preliminary test results

    International Nuclear Information System (INIS)

    Miyahara, Shinya; Ara, Kuniaki

    1998-08-01

    To study a sodium leak and combustion behavior phenomenologically and to construct the mechanistic evaluation method, an experimental series of a sodium droplet burning in free fall is under way. In this study, the accuracy of measurement technique used in the preliminary test was assessed and the modified technique was proposed for the next test series. Analytical study of the test results was also conducted to deduce dominant parameters and important measurement items which would play an important role in the droplet combustion behavior. The results and conclusions are as follows: (1) Assessment of measurement accuracy and modified technique proposed for the next test series. a) Control accuracy of sodium supply system using β-alumina solid electrolyte was sufficient for generation of objective size of single droplet. However, it is necessary to calibrate the correlation between the quantity of electric charge for sodium supply system and that of supplied sodium. b) Measurement accuracy of falling velocity using high-speed video was ±0.33 m/s at an upper part and ±0.48 m/s at a lower part of the measurement. To reduce the error, a high-speed stroboscopic method is recommended to measure the falling velocity of droplet. (2) Results of analytical study and deduced dominant parameters and important measurement items. a) The falling behavior of a burning droplet was described solving the equation of free falling motion for a rigid sphere. In the case of higher falling height, it is necessary to study the burning effects on the falling behavior. b) The mass burned of a falling droplet was calculated using the combustion model according to 'D 2 ' law during the full burning phase. It is necessary to study the dominant chemical reaction in the burning flame because the mass burned depends on the composition of the reaction products. c) The mass burned was calculated using surface oxidation model for preignition phase together with above model. However, it is

  17. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, C. A. A.; Smilde, A. K.; Doornbos, D. A.

    1993-01-01

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  18. COMPARISON OF EXPERIMENTAL-DESIGNS COMBINING PROCESS AND MIXTURE VARIABLES .2. DESIGN EVALUATION ON MEASURED DATA

    NARCIS (Netherlands)

    DUINEVELD, CAA; SMILDE, AK; DOORNBOS, DA

    The construction of a small experimental design for a combination of process and mixture variables is a problem which has not been solved completely by now. In a previous paper we evaluated some designs with theoretical measures. This second paper evaluates the capabilities of the best of these

  19. Methodology to evaluate the impact of the erosion in cultivated floors applying the technique of the 137CS

    International Nuclear Information System (INIS)

    Gil Castillo, R.; Peralta Vital, J.L.; Carrazana, J.; Riverol, M.; Penn, F.; Cabrera, E.

    2004-01-01

    The present paper shows the results obtained in the framework of 2 Nuclear Projects, in the topic of application of nuclear techniques to evaluate the erosion rates in cultivated soils. Taking into account the investigations with the 137 CS technique, carried out in the Province of Pinar del Rio, was obtained and validated (first time) a methodology to evaluate the erosion impact in a cropland. The obtained methodology includes all relevant stages for the adequate application of the 137 CS technique, from the initial step of area selection, the soil sampling process, selection of the models and finally, the results evaluation step. During the methodology validation process in soils of the Municipality of San Juan y Martinez, the erosion rates estimated by the methodology and the obtained values by watershed segment measures (traditional technique) were compared in a successful manner. The methodology is a technical guide, for the adequate application of the 137 CS technique to estimate the soil redistribution rates in cultivated soils

  20. An evaluation testing technique of single event effect using Beam Blanking SEM

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, J; Hada, T; Pesce, A; Akutsu, T; Matsuda, S [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Igarashi, T; Baba, S

    1997-03-01

    Beam Blanking SEM (Scanning Electron Microscope) testing technique has been applied to CMOS SRAM devices to evaluate the occurence of soft errors on memory cells. Cross-section versus beam current and LET curves derived from BBSEM and heavy ion testing technique, respectively, have been compared. A linear relation between BBSEM current and heavy ion LET has been found. The purpose of this study was to demonstrate that the application of focused pulsed electron beam could be a reliable, convenient and inexpensive tool to investigate the effects of heavy ions and high energy particles on memory devices for space application. (author)