WorldWideScience

Sample records for experimental carotid sidewall

  1. Models of experimental saccular aneurysms of carotid arteries in canine

    International Nuclear Information System (INIS)

    Zhang Haixia; Cheng Yingsheng; Li Minghua

    2006-01-01

    Objective: To study the availability by making experimental saccular aneurysm models of carotid arteries in canine similar to human intracranial aneurysms. Methods: Twenty healthy canines with experimental saccular side-wall aneurysms of carotid arteries were created successfully by surgery. Results: Forty experimental saccular side-wall aneurysms of carotid arteries were created successfully with 36 aneurysms and parent arteries maintaining patency with each other and four spontaneously occluded confirmed by angiography. Model successful rate reached 90%. Conclusions: Experimental saccular side-wall aneurysms of carotid arteries in canines were one of best models created for simulating human intracranial aneurysms. (authors)

  2. Experimental and theoretical study of the operation of longitudinal sidewalls in reinforced concrete superstructures

    Science.gov (United States)

    Bokarev, Sergey; Efimov, Stefan

    2017-11-01

    In the present article, we report results of a laboratory experimental study of reinforced-concrete superstructure fragments with extended longitudinal boxing sidewalls. The study included laboratory tests and numerical experiments performed using a finite element model of fragments generated in specialized simulation software. The distribution of horizontal pressures over the height of longitudinal boxing sidewalls, the dependence of the bending moment in the root section of the sidewalls on the ballast-bed thickness under sleepers, and some other characteristics were examined. The results of the experimental and theoretical study have shown a good convergence of obtained data to each other and to the data obtained by an improved engineering calculation procedure proposed by the present authors.

  3. Establishing experimental model of human internal carotid artery siphon segment in canine common carotid artery

    International Nuclear Information System (INIS)

    Cui Xuee; Li Minghua; Wang Yongli; Cheng Yingsheng; Li Wenbin

    2005-01-01

    Objective: To study the feasibility of establishing experimental model of human internal carotid artery siphon segment in canine common carotid artery (CCA) by end-to-end anastomoses of one side common carotid artery segment with the other side common carotid artery. Methods: Surgical techniques were used to make siphon model in 8 canines. One side CCA was taken as the parent artery and anastomosing with the cut off contra-lateral CCA segment which has passed through within the S-shaped glass tube. Two weeks after the creation of models angiography showed the model siphons were patent. Results: Experimental models of human internal carotid artery siphon segment were successfully made in all 8 dogs. Conclusions: It is practically feasible to establish experimental canine common carotid artery models of siphon segment simulating human internal carotid artery. (authors)

  4. An experimental study of the effects of bodyside compression on forward swept sidewall compression inlets ingesting a turbulent boundary layer

    Science.gov (United States)

    Rodi, Patrick E.

    1993-01-01

    Forward swept sidewall compression inlets have been tested in the Mach 4 Blowdown Facility at the NASA Langley Research Center to study the effects of bodyside compression surfaces on inlet performance in the presence of an incoming turbulent boundary layer. The measurements include mass flow capture and mean surface pressure distributions obtained during simulated combustion pressure increases downstream of the inlet. The kerosene-lampblack surface tracer technique has been used to obtain patterns of the local wall shear stress direction. Inlet performance is evaluated using starting and unstarting characteristics, mass capture, mean surface pressure distributions and permissible back pressure limits. The results indicate that inlet performance can be improved with selected bodyside compression surfaces placed between the inlet sidewalls.

  5. Sidewall coring shell

    Energy Technology Data Exchange (ETDEWEB)

    Edelman, Ya A; Konstantinov, L P; Martyshin, A N

    1966-12-12

    A sidewall coring shell consists of a housing and a detachable core catcher. The core lifter is provided with projections, the ends of which are situated in another plane, along the longitudinal axis of the lifter. The chamber has corresponding projections.

  6. Mechanical seal with textured sidewall

    Energy Technology Data Exchange (ETDEWEB)

    Khonsari, Michael M.; Xiao, Nian

    2017-02-14

    The present invention discloses a mating ring, a primary ring, and associated mechanical seal having superior heat transfer and wear characteristics. According to an exemplary embodiment of the present invention, one or more dimples are formed onto the cylindrical outer surface of a mating ring sidewall and/or a primary ring sidewall. A stationary mating ring for a mechanical seal assembly is disclosed. Such a mating ring comprises an annular body having a central axis and a sealing face, wherein a plurality of dimples are formed into the outer circumferential surface of the annular body such that the exposed circumferential surface area of the annular body is increased. The texture added to the sidewall of the mating ring yields superior heat transfer and wear characteristics.

  7. Ultrasonographic analysis versus histopathologic evaluation of carotid advanced atherosclerotic stenosis in an experimental rabbit model.

    Science.gov (United States)

    Mehrad, Hossein; Mokhtari-Dizaji, Manijhe; Ghanaati, Hossein; Shahbazfar, Amir-Ali; Salehnia, Mojdeh

    2012-08-01

    Advanced carotid atherosclerosis with severe stenosis (>70%) is a major clinical risk factor for ischemic stroke. Our ability to test new protocols for the treatment of atherosclerotic stenosis in humans is limited for obvious ethical reasons; therefore, a suitable animal model is required. The aim of this study was to generate an easily reproducible and inexpensive experimental rabbit carotid model of advanced atherosclerosis with morphological similarities to the human disease and the subsequent assessment of the reliability of B-mode ultrasound technology in the study of lumen area stenosis in this model. Briefly, New Zealand white rabbits underwent primary perivascular cold injury at the right common carotid artery followed by a 1.5% cholesterol-rich diet injury for eight weeks. All of the rabbits' arteries were imaged by B-mode ultrasound weekly, after which the rabbits were sacrificed, and their vessels were processed for histopathology. Ultrasound longitudinal view images from three cardiac cycles were processed by a new computerized analyzing method based on dynamic programming and maximum gradient algorithm for measurement of instantaneous changes in arterial wall thickness and lumen diameter in sequential ultrasound images. Histopathology results showed progressive changes, from the lipid-laden cells and fibrous connective tissue proliferation in neointimal layer, up to the fibro-lipid plaque formation, resulting in vessel wall thickening, remodeling and lumen stenosis. The B-mode ultrasound images and the histologic measurements showed an increase in the mean wall thickness and the lumen area stenosis within eight weeks. Quantitative and morphometric analysis of the mean wall thickness and the lumen area stenosis percentage showed a significant correlation between the B-mode ultrasound and the histological measurements at each time point (R = 0.989 and R = 0.995, p < 0.05, respectively). In conclusion, we successfully produced advanced atherosclerosis in

  8. Comparison of I-123 IMP cerebral uptake and MR spectroscopy following experimental carotid occlusion

    International Nuclear Information System (INIS)

    Holman, B.L.; Jolesz, F.A.; Polak, J.F.; Kronauge, J.F.; Adams, D.F.

    1985-01-01

    Both I-123 IMP scintigraphy and MRI have been suggested as sensitive detectors of changes shortly after acute cerebral infarction. We compared the uptake of N-isopropyl I-123 p-iodoamphetamine (IMP) and MR spectroscopy of the brain after internal carotid artery ligation. Thirteen gerbils were lightly anesthetized with ether. After neck dissection, an internal carotid artery was occluded. After 2.8 hours, 100 muCi I-123 IMP was injected intravenously into the 13 experimental animals plus three controls. Seven gerbils remained asymptomatic while six developed hemiparesis. At 3 hours after ligation, the animals were killed. The brains were bisected and T1 and T2 relaxation times were determined for the right and left hemispheres by MR spectroscopy immediately after dissection. I-123 IMP uptake was then determined in the samples. Interhemispheric differences in uptake for I-123 IMP were 0.1 +/- 1.7% (SEM) in the control, 33.5 +/- 10% in the asymptomatic and 54.6 +/- 9.7% in the symptomatic animals. Significant differences were seen with I-123 IMP in 6/7 asymptomatic and 6/6 symptomatic animals. In conclusion, I-123 is more sensitive than T1 or T2 relaxation times for the detection of cerebral perfusion abnormalities. Prolongation in T1 and T2 relaxation times correlates closely with increased brain tissue water content and the development of symptoms, indicators of structural brain damage and probable infarction

  9. Influence of structured sidewalls on the wetting states and superhydrophobic stability of surfaces with dual-scale roughness

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Huaping, E-mail: wuhuaping@gmail.com [Key Laboratory of E& M (Zhejiang University of Technology), Ministry of Education & Zhejiang Province, Hangzhou 310014 (China); State Key Laboratory of Structural Analysis for Industrial Equipment, Dalian University of Technology, Dalian 116024 (China); Zhu, Kai; Wu, Bingbing [Key Laboratory of E& M (Zhejiang University of Technology), Ministry of Education & Zhejiang Province, Hangzhou 310014 (China); Lou, Jia [Piezoelectric Device Laboratory, Department of Mechanics and Engineering Science, Ningbo University, Ningbo, Zhejiang 315211 (China); Zhang, Zheng [Key Laboratory of E& M (Zhejiang University of Technology), Ministry of Education & Zhejiang Province, Hangzhou 310014 (China); Chai, Guozhong, E-mail: chaigz@zjut.edu.cn [Key Laboratory of E& M (Zhejiang University of Technology), Ministry of Education & Zhejiang Province, Hangzhou 310014 (China)

    2016-09-30

    Highlights: • Apparent contact angle equation of all wetting states on dual-scale rough surfaces is derived. • Structured sidewalls can improve superhydrophobicity than smooth sidewalls. • Structured sidewalls can enlarge ACA than smooth sidewalls. • Structured sidewalls present an advantage over smooth sidewalls in terms of enhancing superhydrophobic stability. - Abstract: The superhydrophobicity of biological surfaces with dual-scale roughness has recently received considerable attention because of the unique wettability of such surfaces. Based on this, artificial micro/nano hierarchical structures with structured sidewalls and smooth sidewalls were designed and the influences of sidewall configurations (i.e., structured and smooth) on the wetting state of micro/nano hierarchical structures were systematically investigated based on thermodynamics and the principle of minimum free energy. Wetting transition and superhydrophobic stability were then analyzed for a droplet on dual-scale rough surfaces with structured and smooth sidewalls. Theoretical analysis results show that dual-scale rough surfaces with structured sidewalls have a larger “stable superhydrophobic region” than those with smooth sidewalls. The dual-scale rough surfaces with smooth sidewalls can enlarge the apparent contact angle (ACA) without improvement in the superhydrophobic stability. By contrast, dual-scale rough surfaces with structured sidewalls present an advantage over those with smooth sidewalls in terms of enlarging ACA and enhancing superhydrophobic stability. The proposed thermodynamic model is valid when compared with previous experimental data and numerical analysis results, which is helpful for designing and understanding the wetting states and superhydrophobic stability of surfaces with dual-scale roughness.

  10. Experimental study on representation of flow on the bifurcated carotid arterial phantoms using magnetic resonance angiography

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Rhim, Yoon Chul; Kim, Kyung Oh; Suh, Sang Ho; Jin, En Hao

    1995-01-01

    A common finding of carotid artery on magnetic resonance angiograms(MRAs) is a signal dropout along the posterior wall of carotid bulb due to reverse flow. The purpose of this study is to evaluate variable flow patterns on bifurcated carotid arterial phantoms using steady-state flow. We designed phantoms of a bifurcated carotid artery with acrylic materials. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF), color Doppler imaging, and computational fluid dynamics (CFD) within the phantoms constructed of an automated closed-type circulatory system filled with 4% sugar solution. These findings were compared with findings obtained from normal volunteers. Axial 3D-TOF MRA images exhibited closer resemblance to the contour of the inner wall of phantoms when compared to coronal 2D-TOF MRA imaging. However, 2D-TOF MRA showed good contrast difference of signal intensities between forward flow area and reverse flow area. Dark zones with reduced signal intensities due to reversed flow were separated from the outer wall of the internal and external carotid arteries by a thin layer of forward flow along the wall on the source slice image of MRA. The general hemodynamics of the phantoms on MRA were identical to hemodynamics on color Doppler imaging and CFD. The results obtained with the phantoms matched the findings on normal volunteers. Although representations of bifurcated carotid arterial phantoms on axial 3D-TOF MRA were excellent if ideally designed, the zone of reversed flow could be a significant factor in creating distorted image when the zone of reversed flow contacted directly with curved or deformed arterial wall

  11. Micro-CT of Carotid Arteries: A Tool for Experimental Studies

    International Nuclear Information System (INIS)

    Mohr, Andreas; Wenke, Ruediger; Roemer, Frank W.; Lynch, John A.; Gatzka, Christian; Priebe, Markus; Guermazi, Ali; Grigorian, Mikayel; Heller, Martin; Mueller-Huelsbeck, Stefan

    2004-01-01

    Micro-computed tomography (micro-CT) is a high-resolution, nondestructive tool for two- and three-dimensional imaging and quantification. The ability of this technique to assess atherosclerosis of the carotid artery was evaluated in three human cadaver samples based on the original axial acquisitions, multiplanar reconstructions and volume rendering techniques. Quantitative analysis included the calculation of: (1) the original lumen perimeter, original lumen area, plaque area, residual lumen area, calcified area and gross sectional area reduction of the vascular lumen from two-dimensional slices; (2) the total tissue volume, soft tissue volume and calcified tissue volume from the three-dimensional data set. This preliminary study demonstrates the potential of micro-CT as a supplementary method for the two- and three-dimensional ex vivo evaluation of carotid atherosclerosis

  12. Computational and experimental assessment of influences of hemodynamic shear stress on carotid plaque.

    Science.gov (United States)

    Zhou, Hui; Meng, Long; Zhou, Wei; Xin, Lin; Xia, Xiangxiang; Li, Shuai; Zheng, Hairong; Niu, Lili

    2017-07-29

    Studies have identified hemodynamic shear stress as an important determinant of endothelial function and atherosclerosis. In this study, we assess the influences of hemodynamic shear stress on carotid plaques. Carotid stenosis phantoms with three severity (30, 50, 70%) were made from 10% polyvinyl alcohol (PVA) cryogel. The phantoms were placed in a pulsatile flow loop with the same systolic/diastolic phase (35/65) and inlet flow rate (16 L/h). Ultrasonic particle imaging velocimetry (Echo PIV) and computational fluid dynamics (CFD) were used to calculate the velocity profile and shear stress distribution in the carotid stenosis phantoms. Inlet/outlet boundary conditions used in CFD were extracted from Echo PIV experiments to make sure that the results were comparable. Echo PIV and CFD results showed that velocity was largest in 70% than those in 30 and 50% at peak systole. Echo PIV results indicated that shear stress was larger in the upper wall and the surface of plaque than in the center of vessel. CFD results demonstrated that wall shear stress in the upstream was larger than in downstream of plaque. There was no significant difference in average velocity obtained by CFD and Echo PIV in 30% (p = 0.25). Velocities measured by CFD in 50% (93.01 cm/s) and in 70% (115.07 cm/s) were larger than those by Echo PIV in 50% (60.26 ± 5.36 cm/s) and in 70% (89.11 ± 7.21 cm/s). The results suggested that Echo PIV and CFD could obtain hemodynamic shear stress on carotid plaques. Higher WSS occurred in narrower arteries, and the shoulder of plaque bore higher WSS than in bottom part.

  13. Acute recanalization of carotid stenosis is not proper: an experimental ischaemic stroke study.

    Science.gov (United States)

    Kong, Qingtao; Hafeez, Adam; Yu, Wang; Ren, Changhong; Geng, Xiaokun; Xiao, Yao; Liu, Shimeng; Zhang, Ying; Mao, Ruili; Zhou, Jiying; Ding, Yuchuan; Ji, Xunming

    2015-05-01

    In a rat common carotid artery (CCA) stenosis model, the author determined the function of blood-brain barrier (BBB) at different time points and established an optimal time for CCA recanalization in rats with CCA stenosis combined with cerebral infarction. Common carotid artery severe stenosis combined with cerebral infarction was divided into two groups: CCA stenosis group (n = 48) and CCA stenosis recanalization group (n = 48). Common carotid artery stenosis recanalization was opened at time points of 1, 2, 3, 5, 7 and 14  days. Twenty-four hours after recanalization, neurological behaviour, motor function, brain water content and immunohistochemistry of laminin and fibronectin were used to assess brain injury. The peak systolic velocity (PSV) determined by colour Doppler flow imaging (CDFI) was used to assess blood flow of the CCA. In contrast to CCA stenosis without recanalization, in which severe neurological deficits and foot fault were observed at 1, 2 and 3  days, significantly less neurological deficits at 14 days and less foot fault placing at 5, 7 and 14  days were observed after recanalization (P vs acute phase), the levels of basal laminar proteins were significantly (P < 0.05) enhanced by vascular recanalization in both the ischaemic core and penumbra. Peak systolic velocity of CCA after recanalization reached the control level without stenosis. Our study suggests that the optimal time to open the CCA stenosis complicating cerebral infarction is at or after 7  days of CCA stenosis.

  14. Experimental studies on canine terminal carotid arterial aneurysm models pre- and post-embolized with microcoil

    International Nuclear Information System (INIS)

    Wang Qihong; Zhou Liangfu; Gong Jianqiu; Dai Jianhua; Zhang Xiaojun; Zhang Xinyuan

    2005-01-01

    Objective: To establish canine terminal saccular aneurysm model of common carotid artery (CCA), and evaluate the images and hemodynamic changes of aneurysm cavities pre- and post-embolized with microcoil (MC). Methods: Seven CCA terminal saccular aneurysm models had been created by using improved microsurgical technique. Seven to fourteen days after surgery, models were undergone color Doppler, Magnetic resonance image (MRI), Magnetic resonance angiography (MRA), digital subtraction angiography (DSA), and then the analysis of computational fluid dynamics (CFD) on these animal models were conducted. Afterwards they were compactly packed with MC, and then aneurysms again were examed under these methods, and simulation of pathological changes. Results: Models were created successfully with good MC compactly pack aneurysm cavities. DSA combined with other imaging methods can improve the diagnosis of aneurysms completely. CFD models can show the imitation hemodynamics of canine carotid aneurysms. Conclusions: This kind of aneurysm model is an ideal one on the area for the research of aneurysm embolization. Non-DSA imaging examination can noninvasively, repeatedly, clearly evaluate aneurysms pre- and post-embolized with MC. The interference on the inflow zone of the aneurysm is an effective method for cure and preventing recurrence of aneurysms. (authors)

  15. Basin sidewall effects during comparable boom testing

    International Nuclear Information System (INIS)

    DeVitis, D.S.; Hannon, L.

    1995-01-01

    A quantitative investigation of the effects of boom sidewall clearance during first and gross oil loss speed tests was discussed. A second measure of sidewall was quantified in terms of flow characteristics at specific location in the boom apex. The test boom was rigged in 5 different configurations. First oil loss and gross oil loss tow speeds, and relative horizontal flow velocities within the boom apex were obtained for each configuration. Flow velocities of 0.5 to 1.5 knots in 0.25 knot increments were measured. Flow velocities illustrated similar flow characteristics within the apex regardless of side wall clearance. The results of the study illustrated that boom to basin sidewall clearance may be an independent test parameter without a significant bias. 5 tabs., 8 figs.,

  16. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  17. Correlation of experimental rCBF determinations in goats with flow measurements from a Doppler-modified carotid artery shunt

    International Nuclear Information System (INIS)

    Loftus, C.M.; Silvidi, J.A.; Becker, J.A.; Miller, B.V.; Bernstein, D.D.

    1989-01-01

    A carotid artery shunt system has been developed that continuously monitors blood flow rates by embedding a Doppler crystal in the shunt wall. The crystal ranges through a liquid lens that enables it to be placed without violation of the shunt lumen. Because the crystal is at a fixed angle (45 degrees) to the axis of blood flow and the diameter of the lumen remains constant, a linear relationship exists between flow rates and the Doppler velocity signal. This shunt system was previously tested in vitro using a pulsatile pump and was found to be accurate to within 4.7% of the actual flow rate. In the present study, animal (goat) experiments were performed consisting of simultaneous carotid shunt flow and bilateral rCBF measurements by the radiolabeled microsphere technique to determine in vivo the accuracy of this Doppler modified shunt and to ascertain the ability of shunt flow to increase in the face of acute contralateral carotid occlusion. Data from five animals show that in vivo shunt flow can be recorded to within 13% of control rCBF and that shunt flow increases nearly 50% under conditions of distal demand (contralateral carotid occlusion). This device may prove useful in laboratory studies of carotid shunt dynamics and in clinical practice to quickly detect correctable shunt flow abnormalities

  18. Important casual association of carotid body and glossopharyngeal nerve and lung following experimental subarachnoid hemorrhage in rabbits. First report.

    Science.gov (United States)

    Yolas, Coskun; Kanat, Ayhan; Aydin, Mehmet Dumlu; Turkmenoglu, Osman Nuri; Gundogdu, Cemal

    2014-01-15

    The glossopharyngeal nerves (GPNs) and carotid bodies (CBs) have an important role in the continuation of the cerebral autoregulation and cardiorespiratory functions. The relationship between degenerative injury of CB and the GPN in subarachnoid hemorrhage (SAH) was studied. Twenty rabbits were included in this study. Five of them (n=5) were used as control group. The remaining animals (n=15) were exposed to experimental SAH. In the six animals of the SAH group, severe signs of illness were observed, and these six animals were killed in the first week after SAH. Others animals (n=9) were followed for 20 days and then sacrificed. GPNs and CBs were examined and, the live and degenerated GPN axon number, and of CB neuron numbers were stereologically estimated. The mean number of live neurons in CBs was 4206.67±148.35 and live axons of GPNs were 1211.66±14.29 in the animals of the control group. The number of degenerated neurons of CBs was 2065±110.27 and the number of degenerated axons of GPNs was 530.83±43.48 in early killed animals with SAH. The number of degenerated neurons of CBs and the number of degenerated axons of GPNs were found as 1013.89±4184 and 2270.5±134.38 in the living animals with SAH, respectively. High number of degenerated axons of GPN and neurons of CBs of the early killed animals suggest that the mortality in early SAH might be due to GPNs injury secondary to compression of their axons or supplying vessels by the probably herniated brainstem, and secondary denervation injury of CBs, and lung. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  19. A new experimental carotid siphon aneurysm model in canine based on the MR angiography and rapid prototyping technology

    International Nuclear Information System (INIS)

    Xie Jian; Li Minghua; Tan Huaqiao; Zhu Yueqi; Hu Dingjun; Qiao Ruihua; Fan Chunhua

    2009-01-01

    Objective: The aim of the experiment is to make an intracranial aneurysm model in canine. Methods: A digital tube was made based on raw magnetic resonance images of the human intracranial carotid artery. Then 6 tubes were made in the 3D rapid prototyping machine and coated with silicone. Finally we isolated the common carotid arteries of 6 canines and made them go through the tubes and anastomosed them end-to-side to get the aneurysm model. Six stents were implanted after one week. Results: Six aneurysm models were successfully made in canines. The parent artery had similar geometry of the human carotid siphon. All the aneurysms and parent arteries were patent in one week's follow-up. One canine died of excessive anesthesia after stenting. Two vascular models kept patent in one month without stenosis. The other 3 had some stenosis on the bends of the vessel. Conclusions: The aneurysm model in the experiment has high flexibility and reliability. The model provides an effective tool for research and testing neurovascular devices. It's also a useful device to train the neuroradiologists and interventional physicians. (authors)

  20. Method of reducing tungsten selectivity to a contact sidewall

    International Nuclear Information System (INIS)

    Smith, G.C.

    1990-01-01

    This patent describes a method for forming a contact plug on a surface of a semiconductor body. It comprises: forming a dielectric layer over the surface of the semiconductor body, the dielectric layer having an aperture therethrough with sidewalls comprising silicon nitride; depositing a metal into the aperture in such a manner that the metal deposits upon the silicon nitride of the sidewalls of the aperture at a substantially greater rate than upon the surface of the dielectric layer

  1. Friction characteristics of the curved sidewall surfaces of a rotary MEMS device in oscillating motion

    International Nuclear Information System (INIS)

    Wu, Jie; Wang, Shao; Miao, Jianmin

    2009-01-01

    A MEMS device with a configuration similar to that of a micro-bearing was developed to study the friction behavior of the curved sidewall surfaces. This friction-testing device consists of two sets of actuators for normal motion and rotation, respectively. Friction measurements were performed at the curved sidewall surfaces of single-crystal silicon. Two general models were developed to determine the equivalent tangential stiffness of the bush-flexure assembly at the contact point by reducing a matrix equation to a one-dimensional formulation. With this simplification, the motions of the contacting surfaces were analyzed by using a recently developed quasi-static stick-slip model. The measurement results show that the coefficient of static friction exhibits a nonlinear dependence on the normal load. The true coefficient of static friction was determined by fitting the experimental friction curve

  2. Hemodynamic transition driven by stent porosity in sidewall aneurysms.

    Science.gov (United States)

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2015-05-01

    The healing process of intracranial aneurysms (IAs) treated with flow diverter stents (FDSs) depends on the IA flow modifications and on the epithelization process over the neck. In sidewall IA models with straight parent artery, two main hemodynamic regimes with different flow patterns and IA flow magnitude were broadly observed for unstented and high porosity stented IA on one side, and low porosity stented IA on the other side. The hemodynamic transition between these two regimes is potentially involved in thrombosis formation. In the present study, CFD simulations and multi-time lag (MTL) particle imaging velocimetry (PIV) measurements were combined to investigate the physical nature of this transition. Measurable velocity fields and non-measurable shear stress and pressure fields were assessed experimentally and numerically in the aneurysm volume in the presence of stents with various porosities. The two main regimes observed in both PIV and CFD showed typical flow features of shear and pressure driven regimes. In particular, the waveform of the averaged IA velocities was matching both the shear stress waveform at IA neck or the pressure gradient waveform in parent artery. Moreover, the transition between the two regimes was controlled by stent porosity: a decrease of stent porosity leads to an increase (decrease) of pressure differential (shear stress) through IA neck. Finally, a good PIV-CFD agreement was found except in transitional regimes and low motion eddies due to small mismatch of PIV-CFD running conditions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Does the underground sidewall station survey method meet MHSA ...

    African Journals Online (AJOL)

    The question is asked whether or not this method of sur-veying will meet the MHSA standards of accuracy that was developed for typical hangingwall traverse type networks. Results obtained from a survey closure using a network of clusters of four sidewall stations demonstrates that under the described circumstances it will ...

  4. InP nanowire array solar cell with cleaned sidewalls

    NARCIS (Netherlands)

    Cui, Y.; Plissard, S.; Wang, J.; Vu, T.T.T.; Smalbrugge, E.; Geluk, E.J.; de Vries, T.; Bolk, J.; Trainor, M.J.; Verheijen, M.A.; Haverkort, J.E.M.; Bakkers, E.P.A.M.

    2013-01-01

    We have fabricated InP nanowire array solar cells with an axial p-n junction. Catalyst gold nanoparticles were first patterned into an array by nanoimprint lithography. The nanowire array was grown in 19 minutes by vapor-liquid-solid growth. The sidewalls were in-situ etched by HCl and ex-situ

  5. Single-electron transistors fabricated with sidewall spacer patterning

    Science.gov (United States)

    Park, Byung-Gook; Kim, Dae Hwan; Kim, Kyung Rok; Song, Ki-Whan; Lee, Jong Duk

    2003-09-01

    We have implemented a sidewall spacer patterning method for novel dual-gate single-electron transistor (DGSET) and metal-oxide-semiconductor-based SET (MOSET) based on the uniform SOI wire, using conventional lithography and processing technology. A 30 nm wide silicon quantum wire is defined by a sidewall spacer patterning method, and depletion gates for two tunnel junctions of the DGSET are formed by the doped polycrystalline silicon sidewall. The fabricated DGSET and MOSET show clear single-electron tunneling phenomena at liquid nitrogen temperature and insensitivity of the Coulomb oscillation period to gate bias conditions. On the basis of the phase control capability of the sidewall depletion gates, we have proposed a complementary self-biasing method, which enables the SET/CMOS hybrid multi-valued logic (MVL) to operate perfectly well at high temperature, where the peak-to-valley current ratio of Coulomb oscillation severely decreases. The suggested scheme is evaluated by SPICE simulation with an analytical DGSET model, and it is confirmed that even DGSETs with a large Si island can be utilized efficiently in the multi-valued logic.

  6. Carotid Angioplasty and Stenting

    Science.gov (United States)

    Carotid angioplasty and stenting Overview Carotid angioplasty (kuh-ROT-id AN-jee-o-plas-tee) and stenting ... to better see and examine the blood vessels. Food and medications You'll receive instructions on what ...

  7. Polarization and sidewall effects in a coal fired MHD channel - three-dimensional calculation

    International Nuclear Information System (INIS)

    Ishikawa, M.; Scott, M.H.; Wu, Y.C.L.

    1981-01-01

    The effects of slag polarization of electrodes and the sidewall configuration on generator performance are studied experimentally and analytically. An analysis of the voltage-current characteristics between two generator frames measured during the operation of the TP40-07 experiment is given, along with an examination of nonuniformities of interframe voltage. Experimental data show that the polarization effect reduces about 3% of the overall electrical performance of the 60 deg diagonal conducting channel used in the study. Analytically, the effect of polarization on the local current and potential distributions is examined by solving the three-dimensional electrical potential using a finite element method. A moderate increase in conductivity in the vicinity of the cathode-side frame is found to give a calculated leakage resistance which approximates the value derived experimentally. The polarization effect results in a large change in the potential and current distributions near the frame but has a small effect on the overall electrical performance. Alternate sidewall/electrode configurations are treated analytically

  8. Effect of surface roughness of trench sidewalls on electrical properties in 4H-SiC trench MOSFETs

    Science.gov (United States)

    Kutsuki, Katsuhiro; Murakami, Yuki; Watanabe, Yukihiko; Onishi, Toru; Yamamoto, Kensaku; Fujiwara, Hirokazu; Ito, Takahiro

    2018-04-01

    The effects of the surface roughness of trench sidewalls on electrical properties have been investigated in 4H-SiC trench MOSFETs. The surface roughness of trench sidewalls was well controlled and evaluated by atomic force microscopy. The effective channel mobility at each measurement temperature was analyzed on the basis of the mobility model including optical phonon scattering. The results revealed that surface roughness scattering had a small contribution to channel mobility, and at the arithmetic average roughness in the range of 0.4-1.4 nm, there was no correlation between the experimental surface roughness and the surface roughness scattering mobility. On the other hand, the characteristics of the gate leakage current and constant current stress time-dependent dielectric breakdown tests demonstrated that surface morphology had great impact on the long-term reliability of gate oxides.

  9. Insulin sensitivity and carotid intima-media thickness

    DEFF Research Database (Denmark)

    Kozakova, Michaela; Natali, Andrea; Dekker, Jacqueline

    2013-01-01

    Despite a wealth of experimental data in animal models, the independent association of insulin resistance with early carotid atherosclerosis in man has not been demonstrated. APPROACH AND RESULTS: We studied a European cohort of 525 men and 655 women (mean age, 44±8 years) free of conditions known...... to affect carotid wall (diabetes mellitus, hypertension, and dyslipidemia). All subjects received an oral glucose tolerance test, a euglycemic hyperinsulinemic clamp (M/I as a measure of insulin sensitivity), and B-mode carotid ultrasound. In 833 participants (380 men), the carotid ultrasound was repeated...

  10. Steady parallel flow in an evaporating fluid heated from sidewalls

    International Nuclear Information System (INIS)

    Das, Kausik S.

    2009-01-01

    Evaporation is ubiquitous in nature, but very few attempts have been made in the past to couple the effects of evaporation with fluid flow behavior. In this theoretical paper we have discussed the effects of evaporation on the dynamics of steady state thermocapillary convection in a two-dimensional rectangular container. The liquid is heated by differentially heated sidewalls and mass loss from the interface due to evaporation is compensated by the liquid entering into the container through a lower inlet, thus keeping the thickness of the liquid layer constant. We show that for an evaporating liquid one can obtain a plane parallel base state profile which depends on the evaporative mass flux.

  11. Reduction of ambipolar characteristics of vertical channel tunneling field-effect transistor by using dielectric sidewall

    International Nuclear Information System (INIS)

    Park, Chun Woong; Cho, Il Hwan; Choi, Woo Young; Lee, Jong-Ho

    2013-01-01

    Ambipolar characteristics of tunneling FETs have been improved by introducing a novel structure which contains dielectric sidewall in the gate region. In the ambipolar operation mode, gate field effect on intrinsic-drain junction region can be reduced with dielectric sidewall. As a result, ambipolar state tunneling probability is decreased at the intrinsic-drain junction. Since the sidewall region is located near the drain region, tunneling probability of source-intrinsic region is not affected by dielectric sidewall. This asymmetric characteristics means only ambipolar current of tunneling FETs can be prohibited by dielectric sidewall. Reduction of ambipolar characteristic of proposed structure has been evaluated with dimension and location of dielectric sidewall. Quantitative analysis of ambipolar characteristics is also investigated with tunneling. (paper)

  12. Direct fabrication of integrated 3D Au nanobox arrays by sidewall deposition with controllable heights and thicknesses

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Nam-Goo; Lee, Bong Kuk; Kanki, Teruo; Lee, Hea Yeon; Kawai, Tomoji; Tanaka, Hidekazu, E-mail: h-tanaka@sanken.osaka-u.ac.j [Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan)

    2009-09-30

    This paper provides a unique strategy for controlling integrated hollow nanostructure arrays such as boxes or pillars at the nanometer scale. The key merit of this technique is that it can overcome resolution limits by sidewall deposition and deposit various materials using a sputtering method. The sputtering method can be replaced by other dry deposition techniques such as pulsed laser deposition (PLD) for complex functional materials. Furthermore, it can produce low-cost large-area fabrication and high reproducibility using the NIL (nanoimprint lithograph) process. The fabrication method consists of a sequence of bilayer spin-coating, UV-NIL, RIE (reactive ion etching), sputtering, ion milling and piranha cleaning processes. By changing the deposition time and molds, various thicknesses and shapes can be fabricated, respectively. Furthermore, the fabricated Au box nanostructure has a bending zone of the top layer and a {approx}17 nm undercut of the bottom layer as observed by SEM (scanning electron microscope). The sidewall thickness was changed from 12 to 61 nm by controlling the deposition time, and was investigated to understand the relationship with blanket thicknesses and geometric effects. The calculated sidewall thickness matched well with experimental results. Using smaller hole-patterned molds, integrated nanobox arrays, with inner squares measuring {approx}160 nm, and nanopillar arrays, with inside pores measuring {approx}65 nm, were fabricated under the same conditions.

  13. Nonlinear Dynamic Behavior of a Bi-Axial Torsional MEMS Mirror with Sidewall Electrodes

    Directory of Open Access Journals (Sweden)

    Mehmet Ozdogan

    2016-03-01

    Full Text Available Nonlinear dynamic responses of a Micro-Electro-Mechanical Systems (MEMS mirror with sidewall electrodes are presented that are in close agreement with previously-reported experimental data. An analysis of frequency responses reveals softening behavior, and secondary resonances originated from the dominant quadratic nonlinearity. The quadratic nonlinearity is an electromechanical coupling effect caused by the electrostatic force. This effect is reflected in our mathematical model used to simulate the dynamic response of the micro-mirror. The effects of increased forcing and decreased damping on the frequency response are investigated as the mirrors are mostly used in vacuum packages. The results can predict MEMS mirror behaviors in optical devices better than previously-reported models.

  14. Noise transmission through sidewall treatments applicable to twin-engine turboprop aircraft

    Science.gov (United States)

    Grosveld, F. W.

    1983-04-01

    The noise transmission loss characteristics of the sidewall treatment in the propeller plane of a twin-engine turboprop aircraft are experimentally investigated in the NASA Langley Research Center Transmission Loss Facility. The sound attenuation properties of the individual elements of this treatment are evaluated showing least noise transmission loss in the low frequencies (below 500 Hz) where the excitation levels at the propeller blade passage frequency and the first few harmonics are highest. It is shown that single and double wall resonances play an important role in the noise transmission loss values of the treatment at these low frequencies suggesting that a limp mass with a very low resonance frequency serves better as a trim panel than a trim panel having a high structural stiffness. It is indicated that the window structures might be a potential noise control problem.

  15. Current Approaches for Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    Cengiz Köksal

    2010-12-01

    Full Text Available Permanent neurologic injuries and death following stroke, necessitates more vigorous treatment of carotid disease. Carotid stenting and carotid endarterectomy are treatment options in many centers besides medical treatment. Whether the patient is symptomatic or asymtomatic, indications and management strategies for treatment remain controversial. Despite the debate, carotid endarterectomy is still accepted to be the most efficientintervention to decrease risk of stroke due to carotid artery stenosis.

  16. Combined stent implantation and embolization with liquid 2-polyhydroxyethyl methacrylate for treatment of experimental canine wide-necked aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Klisch, J.; Zitt, J.; Schumacher, M. [Section of Neuroradiology, University of Freiburg (Germany); Schellhammer, F. [Department of Radiology, University of Cologne, Cologne (Germany); Scheufler, K.M. [Department of Neurosurgery, University of Freiburg (Germany); Pagenstecher, A. [Department of Neuropathology, University of Freiburg, Freiburg (Germany); Nagursky, H. [Department of Oral and Maxillofacial Surgery, University of Freiburg, Freiburg (Germany)

    2002-06-01

    The purpose of the study was the evaluation of 2-polyhydroxyethyl methacrylate (2-P-HEMA) for endovascular liquid embolization of experimental side-wall aneurysms following stent protection in a canine model. The swelling behaviour and polymerization characteristics of 2-P-HEMA in different solutions were investigated in vitro. Different methods for applications were tested in a latex aneurysm model under pulsatile flow conditions. Twenty broad-based carotid side-wall aneurysms were microsurgically produced in five dogs. Four weeks after surgery self-expandable nitinol stents were placed, covering the orifice of the aneurysms. 2-P-HEMA was injected via a microcatheter, which was positioned through the meshwork of the stent. Control angiography was performed immediately after treatment and after 1, 6 and 9 months. In-vivo stent placement succeeded in all but one case. Two aneurysms occluded spontaneously after stent placement. Combined embolization of 17 aneurysms using a stent and 2-P-HEMA was performed. Eleven aneurysms could be primarily completely occluded (65%). A small remaining neck was evident in six aneurysms. Efflux of 2-P-HEMA during the process of embolization was observed in seven aneurysms, due to an excess volume of 2-P-HEMA. The excessive 2-P-HEMA led to significant vessel stenosis in two cases. Two carotid arteries (three treated aneurysms) occluded after 1 month, due to insufficient anticoagulation management. Histological examination of embolized aneurysms revealed no foreign-body or inflammatory reaction. A smooth neo-intimal layer covered the stented vessel segment. Liquid embolization of side-wall aneurysms with 2-P-HEMA is technically feasible. Embolotherapy of aneurysms with liquid agents still has the risk that embolic material will exit even when it is stent-protected. To avoid this problem, stents with smaller strut diameter and/or additional balloon-protection are required. The inert 2-P-HEMA seems to be a promising agent for combining

  17. Radioimmunoscintigraphy of experimental internal carotid arterial thrombi in dogs with 99mTc-labelled monoclonal anti-activated platelet antibody SZ-51

    International Nuclear Information System (INIS)

    Bao Shiyao; Li Wen; He Guangren; Shao Guofu; Zhang Zhilin; Wu Jinchang

    1995-05-01

    The capacity of McAbSZ-51, which is specific for an α-granule membrane protein (GMP-140) expressed on the surface of activated platelets, to bind to the grafted human thrombus in rabbits was studied. The feasibility of imaging thrombus with 99m Tc-labelled McAbSZ-51 in the internal carotid artery of dog was also explored. The results showed that McAbSZ-51 could bind to the grafted human thrombus in rabbits. The thrombus in internal carotid artery was clearly discerned at 2 to 6 h after injection of 99m Tc-SZ-51, with the optimal imaging time at 2 to 4 h after injection. The radioactivity ratio of thrombus to blood was 6.03 +- 1.09 at 6 to 8 h after injection. It is thus concluded that by using the 99m Tc-labelled McAbSZ-51, the early and specific detection of thrombi formed in vivo was fairly possible and feasible. (3 figs., 1 tab.)

  18. The role of regional nerve block anesthesia for carotid endarterectomy: an experimental comparison with previous series with the use of general anesthesia and barbiturates for cerebral protection.

    Science.gov (United States)

    Agrifoglio, G; Agus, G B; Bonalumi, F; Costantini, A; Carlesi, R

    1987-01-01

    A retrospective analysis was performed on a consecutive series of 60 cases divided into two groups given carotid endarterectomy (C.E.) for atherosclerotic disease. In the first group general anesthesia and barbiturate cerebral protection were employed; in group two, loco-regional anesthesia. Indications and risk factors were similar in the two groups; the surgical procedure was identical. The differences in the results are reported and factors contributing to cerebral protection or reduction in the risk of stroke are analyzed. The analysis indicates that loco-regional anesthesia for C.E. is a reliable method for detecting cerebral ischemia and guaranteeing cerebral protection by means of a temporary shunt when strictly necessary.

  19. Reduce the start current of Smith-Purcell backward wave oscillator by sidewall grating

    International Nuclear Information System (INIS)

    Li, D.; Imasaki, K.; Gao, X.; Yang, Z.; Park, Gun-Sik

    2007-01-01

    A sidewall grating for the Smith-Purcell device is proposed to enhance the coupling of the optical mode with the electron beam and, consequently, relax the stringent requirements to the electron beam. With the help of three-dimensional particle-in-cell simulations, it has been shown that, comparing with the general grating, the usage of a sidewall grating improves the growth rate and dramatically shortens the time for the device to reach saturation. It is also found that the sidewall grating holds the potential to reduce the start current for the operation of a Smith-Purcell backward wave oscillator

  20. Staged bilateral carotid endarterectomy

    DEFF Research Database (Denmark)

    Schroeder, T; Sillesen, H; Engell, Hans Christian

    1986-01-01

    In a series of 56 staged bilateral carotid endarterectomies, new neurologic symptoms developed in 5% and 20% following the first and second procedure, respectively. All complications were transient or minor. The incidence of postendarterectomy hypertension was significantly higher following...... the second procedure, when operations were staged less than 3 weeks apart. A correlation between these hypertensive episodes and the occurrence of new neurologic symptoms could not be shown. However, as this correlation has been proved in several other reports, bilateral carotid endarterectomy is advised...... to be staged at least 3 weeks apart. In addition, a conservative attitude towards contralateral asymptomatic lesions is proposed....

  1. GaN microrod sidewall epitaxial lateral overgrowth on a close-packed microrod template

    Science.gov (United States)

    Duan, Xiaoling; Zhang, Jincheng; Xiao, Ming; Zhang, Jinfeng; Hao, Yue

    2018-05-01

    We demonstrate a GaN growth method using microrod sidewall epitaxial lateral overgrowth (MSELO) on a close-packed microrod template by a nonlithographic technique. The density and distribution of threading dislocations were determined by the density and distribution of microrods and the nucleation model. MSELO exhibited two different nucleation models determined by the direction and degree of substrate misorientation and the sidewall curvature: one-sidewall and three-sidewall nucleation, predicting the dislocation density values. As a result, the threading dislocation density was markedly decreased from 2 × 109 to 5 × 107 cm‑2 with a small coalescence thickness of ∼2 µm for the close-packed 3000 nm microrod sample.

  2. Single-crystal-silicon-based microinstrument to study friction and wear at MEMS sidewall interfaces

    International Nuclear Information System (INIS)

    Ansari, N; Ashurst, W R

    2012-01-01

    Since the advent of microelectromechanical systems (MEMS) technology, friction and wear are considered as key factors that determine the lifetime and reliability of MEMS devices that contain contacting interfaces. However, to date, our knowledge of the mechanisms that govern friction and wear in MEMS is insufficient. Therefore, systematically investigating friction and wear at MEMS scale is critical for the commercial success of many potential MEMS devices. Specifically, since many emerging MEMS devices contain more sidewall interfaces, which are topographically and chemically different from in-plane interfaces, studying the friction and wear characteristics of MEMS sidewall surfaces is important. The microinstruments that have been used to date to investigate the friction and wear characteristics of MEMS sidewall surfaces possess several limitations induced either by their design or the structural film used to fabricate them. Therefore, in this paper, we report on a single-crystal-silicon-based microinstrument to study the frictional and wear behavior of MEMS sidewalls, which not only addresses some of the limitations of other microinstruments but is also easy to fabricate. The design, modeling and fabrication of the microinstrument are described in this paper. Additionally, the coefficients of static and dynamic friction of octadecyltrichlorosilane-coated sidewall surfaces as well as sidewall surfaces with only native oxide on them are also reported in this paper. (paper)

  3. Translumbar carotid arteriography

    International Nuclear Information System (INIS)

    Maxwell, S.L. Jr.; Kwon, O.J.; Millan, V.G.

    1983-01-01

    In seven patients, carotid arteriography and arch aortography were performed using a translumbar catheter exchange sheath which facilitated selective catheterization. No significant complications occurred. The translumbar approach is easier than the auxillary approach, will result in fewer complications, and should be considered whenever a femoral arterial access is unavailable

  4. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study) : an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Joerg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Bradbury, A.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molynewc, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Hendriks, J. M. H.; Hendriks, J. M.

    2010-01-01

    Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid

  5. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  6. Atomic force microscopy deep trench and sidewall imaging with an optical fiber probe

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Hui, E-mail: xiehui@hit.edu.cn; Hussain, Danish; Yang, Feng [The State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, 2 Yikuang, 150080 Harbin (China); Sun, Lining [The State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, 2 Yikuang, 150080 Harbin (China); Robotics and Microsystems Center, Soochow University, 215021 Suzhou (China)

    2014-12-15

    We report a method to measure critical dimensions of micro- and nanostructures using the atomic force microscope (AFM) with an optical fiber probe (OFP). This method is capable of scanning narrow and deep trenches due to the long and thin OFP tip, as well as imaging of steep sidewalls with unique profiling possibilities by laterally tilting the OFP without any modifications of the optical lever. A switch control scheme is developed to measure the sidewall angle by flexibly transferring feedback control between the Z- and Y-axis, for a serial scan of the horizontal surface (raster scan on XY-plane) and sidewall (raster scan on the YZ-plane), respectively. In experiments, a deep trench with tapered walls (243.5 μm deep) and a microhole (about 14.9 μm deep) have been imaged with the orthogonally aligned OFP, as well as a silicon sidewall (fabricated by deep reactive ion etching) has been characterized with the tilted OFP. Moreover, the sidewall angle of TGZ3 (AFM calibration grating) was accurately measured using the switchable scan method.

  7. Sidewall-friction-driven ordering transition in granular channel flows: Implications for granular rheology

    Science.gov (United States)

    Mandal, Sandip; Khakhar, D. V.

    2017-11-01

    We report a transition from a disordered state to an ordered state in the flow of nearly monodisperse granular matter flowing in an inclined channel with planar slide walls and a bumpy base, using discrete element method simulations. For low particle-sidewall friction coefficients, the flowing particles are disordered, however, for high sidewall friction, an ordered state is obtained, characterized by a layering of the particles and hexagonal packing of the particles in each layer. The extent of ordering, quantified by the local bond-orientational order parameter, varies in the cross section of the channel, with the highest ordering near the sidewalls. The flow transition significantly affects the local rheology—the effective friction coefficient is lower, and the packing fraction is higher, in the ordered state compared to the disordered state. A simple model, incorporating the extent of local ordering, is shown to describe the rheology of the system.

  8. Sidewall GaAs tunnel junctions fabricated using molecular layer epitaxy

    Directory of Open Access Journals (Sweden)

    Takeo Ohno and Yutaka Oyama

    2012-01-01

    Full Text Available In this article we review the fundamental properties and applications of sidewall GaAs tunnel junctions. Heavily impurity-doped GaAs epitaxial layers were prepared using molecular layer epitaxy (MLE, in which intermittent injections of precursors in ultrahigh vacuum were applied, and sidewall tunnel junctions were fabricated using a combination of device mesa wet etching of the GaAs MLE layer and low-temperature area-selective regrowth. The fabricated tunnel junctions on the GaAs sidewall with normal mesa orientation showed a record peak current density of 35 000 A cm-2. They can potentially be used as terahertz devices such as a tunnel injection transit time effect diode or an ideal static induction transistor.

  9. Sidewall passivation for InGaN/GaN nanopillar light emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Won Hyuck; Abraham, Michael; Yu, Shih-Ying [Department of Materials Science and Engineering, Pennsylvania State University, University Park, Pennsylvania 16802 (United States); You, Guanjun; Liu, Jie; Wang, Li; Xu, Jian, E-mail: jianxu@engr.psu.edu [Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, Pennsylvania 16802 (United States); Mohney, Suzanne E., E-mail: mohney@ems.psu.edu [Department of Materials Science and Engineering, Pennsylvania State University, University Park, Pennsylvania 16802 (United States); Materials Research Institute, Pennsylvania State University, University Park, Pennsylvania 16802 (United States)

    2014-07-07

    We studied the effect of sidewall passivation on InGaN/GaN multiquantum well-based nanopillar light emitting diode (LED) performance. In this research, the effects of varying etch rate, KOH treatment, and sulfur passivation were studied for reducing nanopillar sidewall damage and improving device efficiency. Nanopillars prepared under optimal etching conditions showed higher photoluminescence intensity compared with starting planar epilayers. Furthermore, nanopillar LEDs with and without sulfur passivation were compared through electrical and optical characterization. Suppressed leakage current under reverse bias and four times higher electroluminescence (EL) intensity were observed for passivated nanopillar LEDs compared with unpassivated nanopillar LEDs. The suppressed leakage current and EL intensity enhancement reflect the reduction of non-radiative recombination at the nanopillar sidewalls. In addition, the effect of sulfur passivation was found to be very stable, and further insight into its mechanism was gained through transmission electron microscopy.

  10. Sidewall-friction-driven ordering transition in granular channel flows: Implications for granular rheology.

    Science.gov (United States)

    Mandal, Sandip; Khakhar, D V

    2017-11-01

    We report a transition from a disordered state to an ordered state in the flow of nearly monodisperse granular matter flowing in an inclined channel with planar slide walls and a bumpy base, using discrete element method simulations. For low particle-sidewall friction coefficients, the flowing particles are disordered, however, for high sidewall friction, an ordered state is obtained, characterized by a layering of the particles and hexagonal packing of the particles in each layer. The extent of ordering, quantified by the local bond-orientational order parameter, varies in the cross section of the channel, with the highest ordering near the sidewalls. The flow transition significantly affects the local rheology-the effective friction coefficient is lower, and the packing fraction is higher, in the ordered state compared to the disordered state. A simple model, incorporating the extent of local ordering, is shown to describe the rheology of the system.

  11. Band-gap sensitive adsorption of fluorine molecules on sidewalls of carbon nanotubes: an ab initio study

    International Nuclear Information System (INIS)

    Choi, Woon Ih; Park, Sohee; Kim, Tae-Eun; Park, Noejung; Lee, Kwang-Ryeol; Lee, Young Hee; Ihm, Jisoon; Han, Seungwu

    2006-01-01

    We report from ab initio calculations that the band-gap sensitive side-wall functionalization of a carbon nanotube is feasible with the fluorine molecule (F 2 ), which can provide a route to the extraction of semiconducting nanotubes by etching away metallic ones. In the small diameter cases like (11, 0) and (12, 0), the nanotubes are easily functionalized with F 2 regardless of their electronic properties. As the diameter becomes larger, however, the fluorination is favoured on metallic CNTs with smaller activation barriers than those of semiconducting ones. Our results suggest that low-temperature exposure to F 2 molecules in the gas phase can make a dominant portion of fluorinated metallic nanotubes and unfluorinated semiconducting ones. This is consistent with recent experimental reports

  12. Aircraft interior noise models - Sidewall trim, stiffened structures, and cabin acoustics with floor partition

    Science.gov (United States)

    Pope, L. D.; Wilby, E. G.; Willis, C. M.; Mayes, W. H.

    1983-01-01

    As part of the continuing development of an aircraft interior noise prediction model, in which a discrete modal representation and power flow analysis are used, theoretical results are considered for inclusion of sidewall trim, stiffened structures, and cabin acoustics with floor partition. For validation purposes, predictions of the noise reductions for three test articles (a bare ring-stringer stiffened cylinder, an unstiffened cylinder with floor and insulation, and a ring-stringer stiffened cylinder with floor and sidewall trim) are compared with measurements.

  13. Investigation of sidewall roughness of the microgrooves manufactured with laser-induced etching technique

    International Nuclear Information System (INIS)

    Oh, Kwang H.; Park, J.B.; Cho, S.I.; Im, H.D.; Jeong, S.H.

    2009-01-01

    A novel laser etching technique utilizing an optical fiber as the laser beam guide is introduced. Depending upon whether a pulsed or a continuous wave (CW) laser is employed as the irradiation source, it was found that the etch depth and surface morphology of the grooves varied significantly. It was then demonstrated that deep microgrooves with smooth sidewalls can be obtained using a hybrid pulse and CW scanning process. The results of laser heating and chemical analyses revealed that sidewall roughness of the microgroove is mainly attributed to surface melting.

  14. A wall shear stress sensor using a pair of sidewall doped cantilevers

    Science.gov (United States)

    Nguyen, Thanh-Vinh; Kazama, Ryohei; Takahashi, Hidetoshi; Takahata, Tomoyuki; Matsumoto, Kiyoshi; Shimoyama, Isao

    2017-07-01

    In this paper, we report on a micro-electro mechanical system (MEMS)-based piezoresistive sensor for measuring shear stress induced by an airflow. The advantages of the proposed sensor include a simple sensing method and a high resonance frequency due to the small size of the sensing elements. Our sensor consists of a pair of 3 µm thick cantilevers with piezoresistors formed on the sidewall of their hinges to detect lateral deformation in the cantilevers induced by an airflow. Each cantilever has a 200 µm  ×  400 µm plate supported by two 150 µm long, 4 µm wide beams. The piezoresistors on the two cantilevers are designed to deform in opposite manners when a shear stress is applied and in the same manner when a pressure is applied. Therefore, the applied shear stress can be detected from the difference in the responses of the two cantilevers without becoming conflated with pressure. In this paper, the design, fabrication and evaluation of the proposed sensor are reported and compared to numerical simulation results. From the experimental results, the resolution of the sensor and its first resonance frequency are 1.3 Pa and 3.9 kHz, respectively. Moreover, we show that the effect of temperature on the readout of the sensor can be eliminated using a temperature-compensating piezoresistor fabricated on the same sensor chip. Finally, using the fabricated sensor, the measurement of the shear stress induced by an airflow with velocity between  -10 and 10 m s-1 is demonstrated.

  15. A wall shear stress sensor using a pair of sidewall doped cantilevers

    International Nuclear Information System (INIS)

    Nguyen, Thanh-Vinh; Shimoyama, Isao; Kazama, Ryohei; Takahashi, Hidetoshi; Takahata, Tomoyuki; Matsumoto, Kiyoshi

    2017-01-01

    In this paper, we report on a micro-electro mechanical system (MEMS)-based piezoresistive sensor for measuring shear stress induced by an airflow. The advantages of the proposed sensor include a simple sensing method and a high resonance frequency due to the small size of the sensing elements. Our sensor consists of a pair of 3 µ m thick cantilevers with piezoresistors formed on the sidewall of their hinges to detect lateral deformation in the cantilevers induced by an airflow. Each cantilever has a 200 µ m  ×  400 µ m plate supported by two 150 µ m long, 4 µ m wide beams. The piezoresistors on the two cantilevers are designed to deform in opposite manners when a shear stress is applied and in the same manner when a pressure is applied. Therefore, the applied shear stress can be detected from the difference in the responses of the two cantilevers without becoming conflated with pressure. In this paper, the design, fabrication and evaluation of the proposed sensor are reported and compared to numerical simulation results. From the experimental results, the resolution of the sensor and its first resonance frequency are 1.3 Pa and 3.9 kHz, respectively. Moreover, we show that the effect of temperature on the readout of the sensor can be eliminated using a temperature-compensating piezoresistor fabricated on the same sensor chip. Finally, using the fabricated sensor, the measurement of the shear stress induced by an airflow with velocity between  −10 and 10 m s −1 is demonstrated. (paper)

  16. Implementation of light extraction improvements of GaN-based light-emitting diodes with specific textured sidewalls

    Science.gov (United States)

    Chen, Chun-Yen; Chen, Wei-Cheng; Chang, Ching-Hong; Lee, Yu-Lin; Liu, Wen-Chau

    2018-05-01

    Textured-sidewall GaN-based light-emitting diodes (LEDs) with various sidewall angles (15-90°) and convex or concave sidewalls prepared using an inductively-coupled-plasma approach are comprehensively fabricated and studied. The device with 45° sidewalls (Device F) and that with convex sidewalls (Device B) show significant improvements in optical properties. Experiments show that, at an injection current of 350 mA, the light output power, external quantum efficiency, wall-plug efficiency, and luminous flux of Device F (Device B) are greatly improved by 18.3% (18.2%), 18.2% (18.2%), 17.3% (19.8%), and 16.6% (18.4%), respectively, compared to those of a conventional LED with flat sidewalls. In addition, negligible degradation in electrical properties is found. The enhanced optical performance is mainly attributed to increased light extraction in the horizontal direction due to a significant reduction in total internal reflection at the textured sidewalls. Therefore, the reported specific textured-sidewall structures (Devices B and F) are promising for high-power GaN-based LED applications.

  17. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2010-03-20

    Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.

  18. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    NARCIS (Netherlands)

    Ederle, J.; Dobson, J.; Featherstone, R.L.; Bonati, L.H.; Worp, H.B. van der; Borst, G.J. de; Lo, T.H.; Gaines, P.; Dorman, P.J.; Macdonald, S.; Lyrer, P.A.; Hendriks, J.M.; McCollum, C.; Nederkoorn, P.J.; Brown, M.M.; Blankensteijn, J.D.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  19. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Jörg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Chan, A.; Chu, P.; Clark, D.; Dewey, H.; Donnan, G.; Fell, G.; Hoare, M.; Molan, M.; Roberts, A.; Roberts, N.; Beiles, B.; Bladin, C.; Clifford, C.; Grigg, M.; New, G.; Bell, R.; Bower, S.; Chong, W.; Holt, M.; Saunder, A.; Than, P. G.; Gett, S.; Leggett, D.; McGahan, T.; Quinn, J.; Ray, M.; Wong, A.; Woodruff, P.; Foreman, R.; Schultz, D.; Scroop, R.; Stanley, B.; Allard, B.; Atkinson, N.; Cambell, W.; Davies, S.; Field, P.; Milne, P.; Mitchell, P.; Tress, B.; Yan, B.; Beasley, A.; Dunbabin, D.; Stary, D.; Walker, S.; Cras, P.; d'Archambeau, O.; Hendriks, J. M. H.; van Schil, P.; St Blasius, A. Z.; Bosiers, M.; Deloose, K.; van Buggenhout, E.; de Letter, J.; Devos, V.; Ghekiere, J.; Vanhooren, G.; Astarci, P.; Hammer, F.; Lacroix, V.; Peeters, A.; Verbist, J.; Blair, J.-F.; Caron, J. L.; Daneault, N.; Giroux, M.-F.; Guilbert, F.; Lanthier, S.; Lebrun, L.-H.; Oliva, V.; Raymond, J.; Roy, D.; Soulez, G.; Weill, A.; Hill, M.; Hu, W.; Hudion, M.; Morrish, W.; Sutherland, G.; Wong, J.; Albäck, A.; Harno, H.; Ijäs, P.; Kaste, M.; Lepäntalo, M.; Mustanoja, S.; Paananen, T.; Porras, M.; Putaala, J.; Railo, M.; Sairanen, T.; Soinne, L.; Vehmas, A.; Vikatmaa, P.; Goertler, M.; Halloul, Z.; Skalej, M.; Brennan, P.; Kelly, C.; Leahy, A.; Moroney, J.; Thornton, J.; Koelemay, M. J. W.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van der Lugt, A.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van Urk, H.; Verhagen, H. J. M.; Bruijninckx, C. M. A.; de Bruijn, S. F.; Keunen, R.; Knippenberg, B.; Mosch, A.; Treurniet, F.; van Dijk, L.; van Overhagen, H.; Wever, J.; de Beer, F. C.; van den Berg, J. S. P.; van Hasselt, B. A. A. M.; Zeilstra, D. J.; Boiten, J.; van Otterloo, J. C. A. de Mol; de Vries, A. C.; Lycklama a Nijeholt, G. J.; van der Kallen, B. F. W.; Blankensteijn, J. D.; de Leeuw, F. E.; Kool, L. J. Schultze; van der Vliet, J. A.; de Borst, G. J.; de Kort, G. A. P.; Kapelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F.; van der Worp, H. B.; Verhagen, H.; Barber, P. A.; Bourchier, R.; Hill, A.; Holden, A.; Stewart, J.; Bakke, S. J.; Krohg-Sørensen, K.; Skjelland, M.; Tennøe, B.; Bialek, P.; Biejat, Z.; Czepiel, W.; Czlonkowska, A.; Dowzenko, A.; Jedrzejewska, J.; Kobayashi, A.; Lelek, M.; Polanski, J.; Kirbis, J.; Milosevic, Z.; Zvan, B.; Blasco, J.; Chamorro, A.; Macho, J.; Obach, V.; Riambau, V.; San Roman, L.; Branera, J.; Canovas, D.; Estela, Jordi; Gaibar, A. Gimenez; Perendreu, J.; Björses, K.; Gottsater, A.; Ivancev, K.; Maetzsch, T.; Sonesson, B.; Berg, B.; Delle, M.; Formgren, J.; Gillgren, P.; Kall, T.-B.; Konrad, P.; Nyman, N.; Takolander, R.; Andersson, T.; Malmstedt, J.; Soderman, M.; Wahlgren, C.; Wahlgren, N.; Binaghi, S.; Hirt, L.; Michel, P.; Ruchat, P.; Engelter, S. T.; Fluri, F.; Guerke, L.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E.-W.; Stierli, P.; Wasner, M.; Wetzel, S.; Bonvin, C.; Kalangos, A.; Lovblad, K.; Murith, M.; Ruefenacht, D.; Sztajzel, R.; Higgins, N.; Kirkpatrick, P. J.; Martin, P.; Varty, K.; Adam, D.; Bell, J.; Crowe, P.; Gannon, M.; Henderson, M. J.; Sandler, D.; Shinton, R. A.; Scriven, J. M.; Wilmink, T.; D'Souza, S.; Egun, A.; Guta, R.; Punekar, S.; Seriki, D. M.; Thomson, G.; Brennan, J. A.; Enevoldson, T. P.; Gilling-Smith, G.; Gould, D. A.; Harris, P. L.; McWilliams, R. G.; Nasser, H.-C.; White, R.; Prakash, K. G.; Serracino-Inglott, F.; Subramanian, G.; Symth, J. V.; Walker, M. G.; Clarke, M.; Davis, M.; Dixit, S. A.; Dorman, P.; Dyker, A.; Ford, G.; Golkar, A.; Jackson, R.; Jayakrishnan, V.; Lambert, D.; Lees, T.; Louw, S.; Macdonald, S.; Mendelow, A. D.; Rodgers, H.; Rose, J.; Stansby, G.; Wyatt, M.; Baker, T.; Baldwin, N.; Jones, L.; Mitchell, D.; Munro, E.; Thornton, M.; Baker, D.; Davis, N.; Hamilton, G.; McCabe, D.; Platts, A.; Tibballs, J.; Cleveland, T.; Dodd, D.; Lonsdale, R.; Nair, R.; Nassef, A.; Nawaz, S.; Venables, G.; Belli, A.; Cloud, G.; Halliday, A.; Markus, H.; McFarland, R.; Morgan, R.; Pereira, A.; Thompson, A.; Chataway, J.; Cheshire, N.; Gibbs, R.; Hammady, M.; Jenkins, M.; Malik, I.; Wolfe, J.; Adiseshiah, M.; Bishop, C.; Brew, S.; Brookes, J.; Jäger, R.; Kitchen, N.; Ashleigh, R.; Butterfield, S.; Gamble, G. E.; McCollum, C.; Nasim, A.; O'Neill, P.; Edwards, R. D.; Lees, K. R.; MacKay, A. J.; Moss, J.

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  20. Crucial role of sidewalls in velocity distributions in quasi-two-dimensional granular gases

    NARCIS (Netherlands)

    van Zon, J.S.; Kreft, J.; Goldman, D.L.; Miracle, D.; Swift, J. B.; Swinney, H. L.

    2004-01-01

    The significance of sidewalls which yield velocity distributions with non-Gaussian tails and a peak near zero velocity in quasi-two-dimensional granular gases, was investigated. It was observed that the particles gained energy only through collisions with the bottom of the container, which was not

  1. Study of shallow trench isolation technology with a poly-Si sidewall buffer layer

    International Nuclear Information System (INIS)

    Juang, M H; Chen, C L; Jang, S L

    2008-01-01

    Shallow trench isolation (STI) technology with a poly-Si buffer layer at the trench sidewall has been studied. At the densification temperature of 950 °C, for the samples without using a poly-Si buffer layer, the resulting junction shows a leakage of about 700 nA cm −2 for a diode area of 100 × 100 µm 2 , primarily due to large peripheral junction leakage. The large leakage is ascribed to the defect generation caused by a thermally induced stress near the trench sidewall. The usage of a poly-Si buffer layer in the trench sidewall is found to significantly improve the junction characteristics. As a result, when a 40 nm poly-Si buffer layer is sandwiched between the Si substrate and the trench-fill silicon oxide, the resultant junctions show a leakage of only about 8 nA cm −2 . This result may reflect the considerably reduced thermally induced stress near the trench sidewall. Furthermore, at the densification temperature of 1100 °C, the usage of a poly-Si buffer layer can help to achieve excellent junctions with a leakage smaller than 5 nA cm −2 for a diode area of 100 × 100 µm 2

  2. MR imaging of carotid webs

    International Nuclear Information System (INIS)

    Boesen, Mari E.; Eswaradass, Prasanna Venkatesan; Singh, Dilip; Mitha, Alim P.; Menon, Bijoy K.; Goyal, Mayank; Frayne, Richard

    2017-01-01

    We propose a magnetic resonance (MR) imaging protocol for the characterization of carotid web morphology, composition, and vessel wall dynamics. The purpose of this case series was to determine the feasibility of imaging carotid webs with MR imaging. Five patients diagnosed with carotid web on CT angiography were recruited to undergo a 30-min MR imaging session. MR angiography (MRA) images of the carotid artery bifurcation were acquired. Multi-contrast fast spin echo (FSE) images were acquired axially about the level of the carotid web. Two types of cardiac phase resolved sequences (cineFSE and cine phase contrast) were acquired to visualize the elasticity of the vessel wall affected by the web. Carotid webs were identified on MRA in 5/5 (100%) patients. Multi-contrast FSE revealed vessel wall thickening and cineFSE demonstrated regional changes in distensibility surrounding the webs in these patients. Our MR imaging protocol enables an in-depth evaluation of patients with carotid webs: morphology (by MRA), composition (by multi-contrast FSE), and wall dynamics (by cineFSE). (orig.)

  3. MR imaging of carotid webs

    Energy Technology Data Exchange (ETDEWEB)

    Boesen, Mari E. [University of Calgary, Department of Biomedical Engineering, Calgary (Canada); Foothills Medical Centre, Seaman Family MR Research Centre, Calgary (Canada); Eswaradass, Prasanna Venkatesan; Singh, Dilip; Mitha, Alim P.; Menon, Bijoy K. [University of Calgary, Department of Clinical Neurosciences, Calgary (Canada); Foothills Medical Centre, Calgary Stroke Program, Calgary (Canada); Goyal, Mayank [Foothills Medical Centre, Calgary Stroke Program, Calgary (Canada); University of Calgary, Department of Radiology, Calgary (Canada); Frayne, Richard [Foothills Medical Centre, Seaman Family MR Research Centre, Calgary (Canada); University of Calgary, Hotchkiss Brain Institute, Calgary (Canada)

    2017-04-15

    We propose a magnetic resonance (MR) imaging protocol for the characterization of carotid web morphology, composition, and vessel wall dynamics. The purpose of this case series was to determine the feasibility of imaging carotid webs with MR imaging. Five patients diagnosed with carotid web on CT angiography were recruited to undergo a 30-min MR imaging session. MR angiography (MRA) images of the carotid artery bifurcation were acquired. Multi-contrast fast spin echo (FSE) images were acquired axially about the level of the carotid web. Two types of cardiac phase resolved sequences (cineFSE and cine phase contrast) were acquired to visualize the elasticity of the vessel wall affected by the web. Carotid webs were identified on MRA in 5/5 (100%) patients. Multi-contrast FSE revealed vessel wall thickening and cineFSE demonstrated regional changes in distensibility surrounding the webs in these patients. Our MR imaging protocol enables an in-depth evaluation of patients with carotid webs: morphology (by MRA), composition (by multi-contrast FSE), and wall dynamics (by cineFSE). (orig.)

  4. Carotid Surgery in a District General Hospital

    Science.gov (United States)

    Fairgrieve, John

    1981-01-01

    The carotid surgical experience of Cheltenham General Hospital over a 13 year period (1968-81) is presented. This includes 42 operations for stenosis, and 12 further operations for carotid body tumour, carotid aneurysm, subclavian steal syndrome and trauma to the internal carotid artery. The operative techniques and complications are briefly discussed and reasons advanced for a more agressive approach to the problems of extra-cerebral carotid disease in this country. PMID:7185417

  5. What Is Carotid Artery Disease?

    Science.gov (United States)

    ... Lack of physical activity . Too much sitting (sedentary lifestyle) and a lack of aerobic activity can worsen other risk factors for carotid artery disease, such as unhealthy blood cholesterol levels, high blood pressure, diabetes, and ...

  6. Intracerebral haemorrhage after carotid endarterectomy

    DEFF Research Database (Denmark)

    Schroeder, T; Sillesen, H; Boesen, J

    1987-01-01

    Among 662 consecutive carotid endarterectomies eight cases of postoperative ipsilateral intracerebral haemorrhage were identified, occurring into brain areas which, preoperatively were without infarction. As blood pressures across the stenosis were routinely measured during surgery, the internal...

  7. Hyperfusion syndrome after carotid endarterectomy

    International Nuclear Information System (INIS)

    Harrison, P.B.; Wong, M.J.; Belzberg, A.; Holden, J.

    1991-01-01

    This article describes the CT scans of two patients who, following carotid endarterectomy, developed headache and seizures suggestive of hyperperfusion syndrome. Their CT scans demonstrated ipsilateral mass effect and white matter hypodensity. One patient progressed to hemorrhage and died. Although infarction is described as the commonest neurologic event to occur after carotid endarterectomy, autopsy or cerebral blood flow studies in these patients suggests that the changes were due to hyperperfusion rather that infarction. (orig.)

  8. Design of a piezoresistive triaxial force sensor probe using the sidewall doping method

    International Nuclear Information System (INIS)

    Kan, Tetsuo; Aoyama, Yuichiro; Takei, Yusuke; Noda, Kentaro; Shimoyama, Isao; Takahashi, Hidetoshi; Binh-Khiem, Nguyen; Matsumoto, Kiyoshi

    2013-01-01

    In this study, we propose a triaxial force measurement sensor probe with piezoresistors fabricated via sidewall doping using rapid thermal diffusion. The device was developed as a tool for measuring micronewton-level forces as vector quantities. The device consists of a 15 µm thick cantilever, two sensing beams and four wiring beams. The length and width of the cantilever are 1240 µm and 140 µm, respectively, with a beam span of 1200 µm and a width of 10–15 µm. The piezoresistors are formed at the root of the cantilever and the sidewalls of the two sensing beams. The sensor spring constants for each axis were measured at k x = 1.5 N m −1 , k y = 3.5 N m −1 and k z = 0.64 N m −1 . We confirmed that our device was capable of measuring triaxial forces with a minimum detectable force at the submicronewton level. (paper)

  9. Friction, adhesion and wear properties of PDMS films on silicon sidewalls

    International Nuclear Information System (INIS)

    Penskiy, I; Gerratt, A P; Bergbreiter, S

    2011-01-01

    This paper demonstrates the first tests of friction, adhesion and wear properties of thin poly(dimethylsiloxane) (PDMS) films on the sidewalls of silicon-on-insulator structures. The test devices were individually calibrated using a simple method that included optical and electrical measurements. The static coefficient of friction versus normal pressure curves were obtained for PDMS–PDMS, PDMS–silicon and silicon–silicon sidewall interfaces. The effects of aging on friction and adhesion properties of PDMS were also evaluated. The results of friction tests showed that the static coefficient of friction follows the JKR contact model, which means that the friction force depends on the apparent area of contact. The wear tests showed high resistance of PDMS to abrasion over millions of cycles.

  10. Prevention of sidewall redeposition of etched byproducts in the dry Au etch process

    International Nuclear Information System (INIS)

    Aydemir, A; Akin, T

    2012-01-01

    In this paper we present a new technique of etching thin Au film in a dual frequency inductively coupled plasma (ICP) system on Si substrate to prevent the redeposition of etched Au particles over the sidewall of the masking material known as veils. First, the effect of the lithography step was investigated. Then the effects of etch chemistry and the process parameters on the redeposition of etched Au particles on the sidewall of the masking material were investigated. The redeposition effect was examined by depositing a thin Ti film over the masking material acting as a hard mask. The results showed that depositing a thin Ti film over the masking material prevents the formation of veils after etching Au in plasma environments for submicron size structures. Based on the results of this study, we propose a new technique that completely eliminates formation of veils after etching Au in plasma environments for submicron size structures. (paper)

  11. Evaluation of Aero Commander sidewall vibration and interior acoustic data: Static operations

    Science.gov (United States)

    Piersol, A. G.; Wilby, E. G.; Wilby, J. F.

    1980-01-01

    Results for the vibration measured at five locations on the fuselage structure during static operations are presented. The analysis was concerned with the magnitude of the vibration and the relative phase between different locations, the frequency response (inertance) functions between the exterior pressure field and the vibration, and the coherent output power functions at interior microphone locations based on sidewall vibration. Fuselage skin panels near the plane of rotation of the propeller accept propeller noise excitation more efficiently than they do exhaust noise.

  12. Modelo experimental estável de aneurisma sacular em artéria carótida de suínos utilizando veia jugular interna Stable experimental model of carotid artery saccular aneurysm in swine using the internal jugular vein

    Directory of Open Access Journals (Sweden)

    Severino Lourenço da Silva Júnior

    2013-04-01

    Full Text Available OBJETIVO: Desenvolver um modelo experimental estável de aneurisma sacular em carótida de suínos utilizando veia jugular interna. MÉTODOS: Em 12 suínos sadios, com peso variando entre 25 e 50kg, cinco machos e sete fêmeas, foi confeccionado aneurisma na artéria carótida comum direita. Após arteriotomia elíptica, foi realizada anastomose terminolateral com coto distal de veia jugular interna. O volume do aneurisma era calculado de maneira que o valor não excedesse em 27 vezes o valor da área da arteriotomia. Após seis dias, era realizada angiografia e análise microscópica do aneurisma para avaliar perviedade e trombose parcial ou total. RESULTADOS: Houve ganho de peso significante dos suínos no intervalo de tempo entre a confecção do aneurisma e a angiografia (p = 0,04. Foi observada perviedade aneurismática em dez suínos (83%. Ocorreram infecções de feridas operatórias em dois animais (16,6%, ambas com início de aparecimento em três dias após a confecção do aneurisma. Análise histológica dos aneurismas mostrou trombos ocluindo parcialmente a luz em nove suínos (75%. Nesses animais, observou-se que, em média, 9% da luz aneurismática estava preenchida por trombos. CONCLUSÃO: Pôde ser desenvolvido um modelo experimental estável de aneurisma sacular em carótida de suínos utilizando veia jugular interna.OBJECTIVE: To develop an experimental model of stable saccular aneurysm in carotid of pigs using the internal jugular vein. METHODS: In 12 healthy pigs, weighing between 25 and 50kg, five males and seven females, we made a right common carotid artery aneurysm. After elliptical arteriotomy, we carried out a terminolateral anastomosis with the distal stump of the internal jugular vein. Aneurysm volume was calculated so that the value did not exceed 27 times the area of the arteriotomy. After six days angiography and microscopic examination were performed to assess patency of the aneurysm and the presence of total or

  13. Experimental Study of Flow Through Carotid Aneurysms

    Science.gov (United States)

    Masoomi, Faezeh; Mejia-Alvarez, Ricardo

    2017-11-01

    There is evidence that traditional endovascular techniques like coiling are not effective for treatment of wide-neck cerebral aneurysms. Flow Diverter Stents (FDS) have emerged as promising devices for treating complex aneurysms since they enable treatment of aneurysms that were considered untreatable before. Recent studies suggest a number of associated risks with FDS, including in-stent thrombosis, perianeurysmal edema, delayed hemorrhage, and perforator occlusions. Chong et al. simulated hemodynamic behavior using patient-specific data. From their study, it is possible to infer that the standard deviation of energy loss could be a good predictor for intervention success. The aim of this study is to investigate the flow in models of cerebral aneurysms before and after FDS insertion using PIV. These models will be based on actual clinical studies and will be fabricated with advanced additive manufacturing techniques. These data will then be used to explore flow parameters that could inform the likelihood of post-intervention aneurysm rupture, and help determine FDS designs that better suit any particular patient before its procedure.

  14. Analysis of Side-Wall Structure of Grown-in Twin-Type Octahedral Defects in Czochralski Silicon

    Science.gov (United States)

    Ueki, Takemi; Itsumi, Manabu; Takeda, Tadao

    1998-04-01

    We analyzed the side-wall structure of grown-in octahedral defects in Czochralski silicon standard wafers for large-scale integrated circuits. There are two types of twin octahedral defects: an overlapping type and an adjacent type. In the twin octahedral defects of the overlapping type, a hole is formed in the connection part. The side-wall layer in the hole part is formed continually and is the same thickness as the side-wall layers of both octahedrons. In the twin octahedral defects of the adjacent type, a partition layer is formed in the connection part. Our electron energy-loss spectroscopy analyses identified that the side-wall layer includes SiO2.

  15. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  16. Experimental Investigation of a Hypersonic Inlet with Variable Sidewall for Flow Control

    Science.gov (United States)

    Rolim, T. C.; Lu, F. K.

    The main function of a scramjet inlet is to decelerate and compress the air for subsequent reaction with the fuel inside the combustor and, of course, contribute toward meeting the thrust requirement for the entire mission by providing adequate mass flow. It is desirable that the inlet be lightweight and that its geometry be capable of producing a uniform flow in an appropriate state to permit efficient mixing and subsequent combustion. Engine cycle analysis indicates that high contraction ratios CR are desirable for achieving high overall engine efficiency.

  17. Using open sidewalls for modelling self-consistent lithosphere subduction dynamics

    Directory of Open Access Journals (Sweden)

    M. V. Chertova

    2012-10-01

    Full Text Available Subduction modelling in regional model domains, in 2-D or 3-D, is commonly performed using closed (impermeable vertical boundaries. Here we investigate the merits of using open boundaries for 2-D modelling of lithosphere subduction. Our experiments are focused on using open and closed (free slip sidewalls while comparing results for two model aspect ratios of 3:1 and 6:1. Slab buoyancy driven subduction with open boundaries and free plates immediately develops into strong rollback with high trench retreat velocities and predominantly laminar asthenospheric flow. In contrast, free-slip sidewalls prove highly restrictive on subduction rollback evolution, unless the lithosphere plates are allowed to move away from the sidewalls. This initiates return flows pushing both plates toward the subduction zone speeding up subduction. Increasing the aspect ratio to 6:1 does not change the overall flow pattern when using open sidewalls but only the flow magnitude. In contrast, for free-slip boundaries, the slab evolution does change with respect to the 3:1 aspect ratio model and slab evolution does not resemble the evolution obtained with open boundaries using 6:1 aspect ratio. For models with open side boundaries, we could develop a flow-speed scaling based on energy dissipation arguments to convert between flow fields of different model aspect ratios. We have also investigated incorporating the effect of far-field generated lithosphere stress in our open boundary models. By applying realistic normal stress conditions to the strong part of the overriding plate at the sidewalls, we can transfer intraplate stress to influence subduction dynamics varying from slab roll-back, stationary subduction, to advancing subduction. The relative independence of the flow field on model aspect ratio allows for a smaller modelling domain. Open boundaries allow for subduction to evolve freely and avoid the adverse effects (e.g. forced return flows of free-slip boundaries. We

  18. Vitamin D modulates the association of circulating insulin-like growth factor-1 with carotid artery intima-media thickness

    NARCIS (Netherlands)

    Ameri, P.; Canepa, M.; Fabbi, P.; Leoncini, G.; Milaneschi, Y.; Mussap, M.; AlGhatrif, M.; Balbi, M.; Viazzi, F.; Murialdo, G.; Pontremoli, R.; Brunelli, C.; Ferrucci, L.

    2014-01-01

    Objective: Experimental evidence indicates that circulating insulin-like growth factor-1 (IGF-1) counteracts vascular aging and atherosclerosis, for which increased carotid artery intima-media thickness (IMT) is a marker. Yet, IGF-1 concentrations have been inconsistently associated with carotid IMT

  19. Physical and computational fluid dynamics models for the hemodynamics of the artiodactyl carotid rete.

    Science.gov (United States)

    O'Brien, Haley D; Bourke, Jason

    2015-12-07

    In the mammalian order Artiodactyla, the majority of arterial blood entering the intracranial cavity is supplied by a large arterial meshwork called the carotid rete. This vascular structure functionally replaces the internal carotid artery. Extensive experimentation has demonstrated that the artiodactyl carotid rete drives one of the most effective selective brain cooling mechanisms among terrestrial vertebrates. Less well understood is the impact that the unique morphology of the carotid rete may have on the hemodynamics of blood flow to the cerebrum. It has been hypothesized that, relative to the tubular internal carotid arteries of most other vertebrates, the highly convoluted morphology of the carotid rete may increase resistance to flow during extreme changes in cerebral blood pressure, essentially protecting the brain by acting as a resistor. We test this hypothesis by employing simple and complex physical models to a 3D surface rendering of the carotid rete of the domestic goat, Capra hircus. First, we modeled the potential for increased resistance across the carotid rete using an electrical circuit analog. The extensive branching of the rete equates to a parallel circuit that is bound in series by single tubular arteries, both upstream and downstream. This method calculated a near-zero increase in resistance across the rete. Because basic equations do not incorporate drag, shear-stress, and turbulence, we used computational fluid dynamics to simulate the impact of these computationally intensive factors on resistance. Ultimately, both simple and complex models demonstrated negligible changes in resistance and blood pressure across the arterial meshwork. We further tested the resistive potential of the carotid rete by simulating blood pressures known to occur in giraffes. Based on these models, we found resistance (and blood pressure mitigation as a whole) to be an unlikely function for the artiodactyl carotid rete. Copyright © 2015 Elsevier Ltd. All

  20. Carotid cavernous fistula after elective carotid endarterectomy: Case report

    Directory of Open Access Journals (Sweden)

    Andres Asser

    2014-12-01

    This is a case to illustrate a rare complication of carotid artery surgery. The patient had atherosclerotic vessel damage of ICA visible on earlier CT scans. This combined with abrupt increase of transmural pressure due to the revascularization procedure could possibly lead to arterial wall rupture and fistula formation.

  1. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  2. Mechanical Stresses in Carotid Plaques

    DEFF Research Database (Denmark)

    Samuel, Samuel Alberg

    simulationer, som tillod beregning af longitudinelle stress-niveauer i den fibrøse kappe. Afhandlingen indeholder tre artikler, som beskriver denne metode. Den første; “Mechanical Stresses in Carotid Plaques using MRI-Based Fluid Structure Interaction Models”, beskriver i detaljer metoden til at danne de...

  3. The structural and electronic properties of monovalent sidewall functionalized double-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Jalili, Seifollah; Jamali, Maryam

    2012-01-01

    Highlights: ► (6,0)-(13,0) DWCNT, built from (6,0) and (13,0) SWCNTs, is a metallic nanotubes. ► NH 2 /(6,0)-(13,0) and COOH/(6,0)-(13,0) is semimetal and semiconductor, respectively. ► In NH 2 /(6,0)-(13,0) electrons transferred mainly from inner tube to NH 2 group. - Abstract: The structural and electronic properties of (6,0)-(13,0) double-walled carbon nanotubes (DWCNTs) and monovalent sidewall functionalized DWCNTs with –NH 2 and –COOH groups were studied using density functional theory. The results show that pure (6,0)-(13,0) DWCNTs are metallic. However, by functionalizing a DWCNT, local distortions are induced in the outer tube sidewall along the radial direction. The resulting structures, NH 2 /(6,0)-(13,0) and COOH/(6,0)-(13,0) DWCNTs, exhibit significant structural changes, and are semimetal with no energy gap and semiconducting with a small energy gap, respectively. In NH 2 /(6,0)-(13,0) DWCNTs, new electronic states are created and distributed on the outer wall and NH 2 group by electron transfer from the inner tube to the NH 2 group. In COOH/(6,0)-(13,0) DWCNTs, new states are created and distributed on the inner wall, but there is insignificant charge transfer between the inner tube and the COOH group. These results confirm that local atomic structural distortion on DWCNTs caused by sidewall functionalization can modify the electronic structures of DWCNTs.

  4. Bayes Clustering and Structural Support Vector Machines for Segmentation of Carotid Artery Plaques in Multicontrast MRI

    Directory of Open Access Journals (Sweden)

    Qiu Guan

    2012-01-01

    Full Text Available Accurate segmentation of carotid artery plaque in MR images is not only a key part but also an essential step for in vivo plaque analysis. Due to the indistinct MR images, it is very difficult to implement the automatic segmentation. Two kinds of classification models, that is, Bayes clustering and SSVM, are introduced in this paper to segment the internal lumen wall of carotid artery. The comparative experimental results show the segmentation performance of SSVM is better than Bayes.

  5. Prediction of transmission loss through an aircraft sidewall using statistical energy analysis

    Science.gov (United States)

    Ming, Ruisen; Sun, Jincai

    1989-06-01

    The transmission loss of randomly incident sound through an aircraft sidewall is investigated using statistical energy analysis. Formulas are also obtained for the simple calculation of sound transmission loss through single- and double-leaf panels. Both resonant and nonresonant sound transmissions can be easily calculated using the formulas. The formulas are used to predict sound transmission losses through a Y-7 propeller airplane panel. The panel measures 2.56 m x 1.38 m and has two windows. The agreement between predicted and measured values through most of the frequency ranges tested is quite good.

  6. Complete resection of locally advanced ovarian carcinoma fixed to the pelvic sidewall and involving external and internal iliac vessels.

    Science.gov (United States)

    Nishikimi, Kyoko; Tate, Shinichi; Matsuoka, Ayumu; Shozu, Makio

    2017-08-01

    Locally advanced ovarian carcinomas may be fixed to the pelvic sidewall, and although these often involve the internal iliac vessels, they rarely involve the external iliac vessels. Such tumors are mostly considered inoperable. We present a surgical technique for complete resection of locally advanced ovarian carcinoma fixed to the pelvic sidewall and involving external and internal iliac vessels. A 69-year-old woman presented with ovarian carcinoma fixed to the right pelvic sidewall, which involved the right external and internal iliac arteries and veins and the right lower ureter, rectum, and vagina. We cut the external iliac artery and vein at the bifurcation and at the inguinal ligament to resect the external artery and vein. Then, we reconstructed the arterial and venous supplies of the right external artery and vein with grafts. After creating a wide space immediately inside of the sacral plexus to allow the tumor fixed to pelvic sidewall with the internal iliac vessels to move medially, we performed total internal iliac vessel resection. We achieved complete en bloc tumor resection with the right external and internal artery and vein, right ureter, vagina, and rectum adhering to the tumor. There were no intra- or postoperative complications, such as bleeding, graft occlusion, infection, or limb edema. Exfoliation from the sacral plexus and total resection with external and internal iliac vessels enables complete resection of the tumor fixed to the pelvic sidewall. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. A study of the mechanisms causing surface defects on sidewalls during Si etching for TSV (through Si via)

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Loh, Woon Leng; Praveen, Sampath Kumar; Murphy, Ramana; Swee, Eugene Tan Kiat

    2013-01-01

    In this paper we report three mechanisms causing surface defects on Si sidewalls during Si etching for TSV. The first mechanism causing surface defects was a downward surface-defect formation due to the participation of the residual polymerizing gas in the transition periods between passivation steps and etch steps. The second mechanism was an upward surface-defect formation due to etchant attacking the interface between the Si and the sidewall polymer. Although the sidewall polymer was thick enough to protect the Si surface, it was not possible to avoid surface defects if the etch step was not switched to the following passivation step in time. The third mechanism was a sponge-like surface-defect formation caused by either poor polymer depositions or voids inside the sidewall polymer. The sponge-like surface defects were formed by Si isotropic etching through the weak points of the sidewall polymer. All three surface defects were considered as the major factors on TSV integration and packaging reliability issues. (paper)

  8. Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.

    Science.gov (United States)

    Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang

    2015-10-01

    The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.

  9. Onset of convection in a porous medium with sidewall heat transfer

    International Nuclear Information System (INIS)

    Kassoy, D.R.; Wang, M.; Weidman, P.D.

    1985-01-01

    A linear stability analysis is developed for convection in a vertically oriented finite slab of saturated porous material. The large vertical sidewall surfaces admit heat transfer while the small endwalls are insulated. A vertical temperature difference is imposed between the upper and lower horizontal surfaces. Results are obtained from an asymptotic evaluation of the exact stability criteria for a rectangular parallelpiped in the limit of small gap width element of → 0, where element of = narrow horizontal dimension/height. The critical Rayleigh number R/sub c/ = 0(element of/sup -2/) when the heat transfer boundary condition is applied directly to the sidewall. The convection mode consists of tightly packed three-dimensional cells with a wave number α = 0(element of/sup -1/2/). Only when the effective Biot number is sufficiently small, 0(element of/sup 2/), are the classical results approached; R/sub c/ → 4π/sup 2/, α/sub c/ = 0(1). If the slab is sandwiched between two impermeable conducting blocks with horizontal extent similar to the slab height, then the small scale modes disappear and R/sub c/ = 0(element of/sup -1/). However, sufficiently thin conducting blocks are compatible with R/sub c/ = 0(element of/sup -2/) and α = 0(element of/sup -1/2/

  10. A numerical model for bird strike on sidewall structure of an aircraft nose

    Directory of Open Access Journals (Sweden)

    Liu Jun

    2014-06-01

    Full Text Available In order to examine the potential of using the coupled smooth particles hydrodynamic (SPH and finite element (FE method to predict the dynamic responses of aircraft structures in bird strike events, bird-strike tests on the sidewall structure of an aircraft nose are carried out and numerically simulated. The bird is modeled with SPH and described by the Murnaghan equation of state, while the structure is modeled with finite elements. A coupled SPH–FE method is developed to simulate the bird-strike tests and a numerical model is established using a commercial software PAM-CRASH. The bird model shows no signs of instability and correctly modeled the break-up of the bird into particles. Finally the dynamic response such as strains in the skin is simulated and compared with test results, and the simulated deformation and fracture process of the sidewall structure is compared with images recorded by a high speed camera. Good agreement between the simulation results and test data indicates that the coupled SPH–FE method can provide a very powerful tool in predicting the dynamic responses of aircraft structures in events of bird strike.

  11. Light-absorbent liquid immersion angled exposure for patterning 3D samples with vertical sidewalls

    International Nuclear Information System (INIS)

    Kumagai, Shinya; Kubo, Hironori; Sasaki, Minoru

    2017-01-01

    To make photolithography patterns on 3D samples, the angled (inclined) exposure technique has been used so far. However, technological issues have emerged in making photolithography patterns on the surface of trench structures. The surface of the trench structures can be covered with a photoresist film by spray-coating but the photoresist film deposited on the sidewalls and bottom of the trench is generally thin. The thin photoresist film deposited inside the trench has been easily overdosed. Moreover, irregular patterns have frequently been formed by the light reflected inside the trench. In this study, we have developed liquid immersion photolithography using a light-absorbent material. The light-reflection inside the trench was suppressed. Various patterns were transferred in the photoresist film deposited on the trench structures which had an aspect ratio of 0.74. Compared to immersion photolithography using pure water under p -polarization light control, the light-absorbent liquid immersion photolithography developed here patterned well the surfaces of the trench sidewalls and bottom. (paper)

  12. Acute internal carotid artery occlusion after carotid endarterectomy

    Directory of Open Access Journals (Sweden)

    Masatoshi Yunoki

    2016-09-01

    Full Text Available We report two cases of acute carotid artery (CA occlusion following carotid endarterectomy (CEA. Case 1: a 58-year-old man was admitted with transient right-sided hemiparesis. Magnetic resonance imaging (MRI and MR angiography (MRA revealed cerebral infarction in the left cerebral hemisphere and left CA stenosis. Ten days after admission, he underwent CEA. 24 h after surgery, he developed right hemiplegia. MRI and MRA demonstrated a slightly enlarged infarction and left internal carotid artery (ICA occlusion. Emergency reoperation was performed and complete recanalization achieved. The patient made a clinically significant recovery. Case 2: a 65 year-old man underwent a right-sided CEA for an asymptomatic 80% CA stenosis. 48 h after surgery, his family noticed he was slightly disorientated. MRI and MRA revealed multiple infarctions and right ICA occlusion. He was treated with antiplatelet therapy without reoperation because sufficient cross-flow from the left ICA through the anterior communicating artery was demonstrated by angiography, and his neurological symptoms were mild. His symptoms gradually alleviated and he was discharged 14 days after surgery. With ICA occlusion after CEA, immediate re-operation is mandatory with severe neurological symptoms, whereas individualized judgement is needed when the symptoms are mild.

  13. Organic geochemistry of heavy/extra heavy oils from sidewall cores, Lower Lagunillas Member, Tia Juana Field, Maracaibo Basin, Venenzuela

    Energy Technology Data Exchange (ETDEWEB)

    Tocco, R.; Alberdi, M. [PDVSA-Inteveo S.A., Caracas (Venezuela)

    2002-10-01

    The study of 22 oils from sidewall cores taken at different depths in the Lower Lagunillas Member, well LSJ-AB, Tia Juana Field, Maracaibo Lake is presented, with the purpose of predicting the intervals that present the best crude oil quality. Differences were detected in the biodegradation levels of the studied samples, which are correlated with the depth at which the sidewall core was taken. The API gravity was considered for the oils from each sidewall core and it was found that toward the top of the sequence, the oils have an API gravity of 10.6-11.2{sup o}C, while toward the base part of the sequence, the well produces extra heavy oils with an API gravity that varies between 8.2 and 8.7{sup o}. 12 refs., 5 figs., 1 tab.

  14. Multidisciplinary approach to carotid stenting.

    Science.gov (United States)

    Mak, C S; Chambers, B R; Clark, D J; Molan, M; Brooks, M; Roberts, N; Fell, G; Roberts, A K; New, G; Donnan, G A

    2011-11-01

    Stroke neurologists, vascular surgeons, interventional neuroradiologists and interventional cardiologists have embraced carotid angioplasty and stenting (CAS) because of potential advantages over carotid endarterectomy (CEA). At Austin Health, a multidisciplinary neuro-interventional group was formed to standardise indications and facilitate training. The aims of this study were to describe our organisational model and to determine whether 30-day complications and early outcomes were similar to those of major trials. A clinical protocol was developed to ensure optimal management. CAS was performed on patients with high medical risk for CEA, with technically difficult anatomy for CEA, or who were randomised to CAS in a trial. From October 2003 to May 2008, 47 patients (34 male, mean age 71.5) underwent CAS of 50 carotid arteries. Forty-three cases had ipsilateral carotid territory symptoms within the previous 12 months. The main indications for CAS were high risk for CEA (n= 17) and randomised to CAS (n= 21). Interventionists were proctored in 27 cases. The procedural success rate was 94% with two cases abandoned because of anatomical problems and one because of on-table angina. Hypotension requiring vasopressor therapy occurred in 12 cases (24%). The duration of follow up was one to 44 months (mean 6.8 months). The 30-day rate of peri-procedural stroke or death was 6% and the one-year rate of peri-procedural stroke or death or subsequent ipsilateral stroke was 10.6%. Restenosis occurred in 13% (all asymptomatic). A multidisciplinary approach is a useful strategy for initiating and sustaining a CAS programme. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  15. Percutaneous transluminal angioplasty of the carotid artery

    International Nuclear Information System (INIS)

    Numaguchi, Y.; Tulane Univ., New Orleans, LA; Puyau, F.A.; Provenza, L.J.; Richardson, D.E.

    1984-01-01

    The successful dilatation of postsurgical concentric stenosis of an internal carotid artery using percutaneous transluminal angioplasty (PTA) is reported here. Only one such case has been previously documented. Review of the literature disclosed 16 patients who received transluminal angioplasty for stenosis of carotid arteries by percutaneous or open arteriotomy techniques. The authors feel that PTA may be the treatment of choice for postoperative concentric stenosis of a short segment of the carotid artery as opposed to surgical repair. (orig.)

  16. DURAL CAROTID-CAVERNOUS FISTULAS

    Directory of Open Access Journals (Sweden)

    Barbara Cvenkel

    2002-12-01

    Full Text Available Background. Dural carotid-cavernous sinus fistulas (CCF are communications fed by meningeal branches of the intracavernous internal carotid artery (ACI or/and external carotid artery (ACE. In contrast to typical CCF, the arteriovenous shunting of blood is usually low flow and low pressure. Spontaneous dural CCF are more common in postmenopausal women. Aetiology is unknown, but congenital malformation or rupture of thin-walled dural arteries within venous sinuses is believed to be the cause.Case reports. 3 cases lacking the typical clinical signs of CCF who had been treated as chronic conjunctivitis, myositis of the extraocular muscle and orbital pseudotumour are presented. Clinical presentation depends on the direction and magnitude of fistular flow and on the anatomy of the collateral branches. If increased blood flow is directed anteriorly in ophthalmic veins the signs of orbito-ocular congestion are present (»redeyed shunt syndrome«. Drainage primarly in the inferior petrosal sinus may cause painful oculomotor and abducens palsies without signs of ocular congestion (»white-eyed shunt syndrome«. Also different therapeutic approaches as well as possible complications are described.Conclusions. For definite diagnosis angiography is obligatory and is also therapeutic as one third to one half of dural CCF close spontaneously. Because of potential severe eye and systemic complications, surgical intervention is indicated only in cases with uncontrolled secondary glaucoma and hypoxic retinopathy.

  17. Nanostructured 2D cellular materials in silicon by sidewall transfer lithography NEMS

    Science.gov (United States)

    Syms, Richard R. A.; Liu, Dixi; Ahmad, Munir M.

    2017-07-01

    Sidewall transfer lithography (STL) is demonstrated as a method for parallel fabrication of 2D nanostructured cellular solids in single-crystal silicon. The linear mechanical properties of four lattices (perfect and defected diamond; singly and doubly periodic honeycomb) with low effective Young’s moduli and effective Poisson’s ratio ranging from positive to negative are modelled using analytic theory and the matrix stiffness method with an emphasis on boundary effects. The lattices are fabricated with a minimum feature size of 100 nm and an aspect ratio of 40:1 using single- and double-level STL and deep reactive ion etching of bonded silicon-on-insulator. Nanoelectromechanical systems (NEMS) containing cellular materials are used to demonstrate stretching, bending and brittle fracture. Predicted edge effects are observed, theoretical values of Poisson’s ratio are verified and failure patterns are described.

  18. Omnidirectional excitation of sidewall gap-plasmons in a hybrid gold-nanoparticle/aluminum-nanopore structure

    Directory of Open Access Journals (Sweden)

    Chatdanai Lumdee

    2016-06-01

    Full Text Available The gap-plasmon resonance of a gold nanoparticle inside a nanopore in an aluminum film is investigated in polarization dependent single particle microscopy and spectroscopy. Scattering and transmission measurements reveal that gap-plasmons of this structure can be excited and observed under normal incidence excitation and collection, in contrast to the more common particle-on-a-mirror structure. Correlation of numerical simulations with optical spectroscopy suggests that a local electric field enhancement factor in excess of 50 is achieved under normal incidence excitation, with a hot-spot located near the top surface of the structure. It is shown that the strong field enhancement from this sidewall gap-plasmon mode can be efficiently excited over a broad angular range. The presented plasmonic structure lends itself to implementation in low-cost, chemically stable, easily addressable biochemical sensor arrays providing large optical field enhancement factors.

  19. Distributed feedback interband cascade lasers with top grating and corrugated sidewalls

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Feng [Thorlabs Quantum Electronics, 10335 Guilford Rd, Jessup, Maryland 20794, USA; Stocker, Michael [Thorlabs Quantum Electronics, 10335 Guilford Rd, Jessup, Maryland 20794, USA; Pham, John [Thorlabs Quantum Electronics, 10335 Guilford Rd, Jessup, Maryland 20794, USA; Towner, Frederick [Thorlabs Quantum Electronics, 10335 Guilford Rd, Jessup, Maryland 20794, USA; Shen, Kun [Thorlabs Quantum Electronics, 10335 Guilford Rd, Jessup, Maryland 20794, USA; Wang, Jie [Center for Nanoscale Materials, Argonne National Laboratory, 9700 S. Cass Avenue, Lemont, Illinois 60439, USA; Lascola, Kevin [Thorlabs Quantum Electronics, 10335 Guilford Rd, Jessup, Maryland 20794, USA

    2018-03-26

    Distributed feedback (DFB) interband cascade lasers (ICLs) with a 1st order top surface grating were designed and fabricated. Partially corrugated sidewalls were implemented to suppress high order lateral modes. The DFB ICLs have 4 mm long and 4.5 mu m wide ridge waveguides and are mounted epi-up on AlN submounts. We demonstrated a continuous-wave (CW) DFB ICL, from a first wafer which has a large detuning of the gain peak from the DFB wavelength, with a side mode suppression ratio of 30 dB. With proper matching of grating feedback and the gain peak wavelength for the second wafer, a DFB ICL was demonstrated with a maximum CW output power and a maximum wall plug efficiency reaching 42 mW and 2%, respectively, at 25 degrees C. The lasing wavelengths of both lasers are around 3.3 mu m at 25 degrees C. Published by AIP Publishing.

  20. Numerical simulation of air distribution in a room with a sidewall jet under benchmark test conditions

    Science.gov (United States)

    Zasimova, Marina; Ivanov, Nikolay

    2018-05-01

    The goal of the study is to validate Large Eddy Simulation (LES) data on mixing ventilation in an isothermal room at conditions of benchmark experiments by Hurnik et al. (2015). The focus is on the accuracy of the mean and rms velocity fields prediction in the quasi-free jet zone of the room with 3D jet supplied from a sidewall rectangular diffuser. Calculations were carried out using the ANSYS Fluent 16.2 software with an algebraic wall-modeled LES subgrid-scale model. CFD results on the mean velocity vector are compared with the Laser Doppler Anemometry data. The difference between the mean velocity vector and the mean air speed in the jet zone, both LES-computed, is presented and discussed.

  1. Common carotid artery disease in Takayasu's arteritis

    International Nuclear Information System (INIS)

    Hamdan, Nabil; Calderon, Luis I; Castro, Pablo and others

    2004-01-01

    Takayasu's arteritis is a disease of unknown etiology with main involvement of the common carotid 5 artery and its branches. we report the case of a 69 years old female patient with Tokays arteritis with 2 bilateral involvements of the common carotid arteries, treated with percutaneous angioplasty and Stent implantation

  2. Hemodynamic significance of internal carotid artery disease

    DEFF Research Database (Denmark)

    Schroeder, T

    1988-01-01

    Neurologic symptoms in the region of an internal carotid artery stenosis are considered to be embolic in most instances. Only in a subgroup has carotid occlusive disease with impairment of the collateral supply, caused a state of hemodynamic failure with marked reduction of perfusion pressure. Th...

  3. Reference gene validation for qPCR in rat carotid body during postnatal development

    Directory of Open Access Journals (Sweden)

    Carroll John L

    2011-10-01

    Full Text Available Abstract Background The carotid bodies are the main arterial oxygen chemoreceptors in mammals. Afferent neural output from the carotid bodies to brainstem respiratory and cardiovascular nuclei provides tonic input and mediates important protective responses to acute and chronic hypoxia. It is widely accepted that the selection of reference genes for mRNA normalization in quantitative real-time PCR must be validated for a given tissue and set of conditions. This is particularly important for studies in carotid body during early postnatal maturation as the arterial oxygen tension undergoes major changes from fetal to postnatal life, which may affect reference gene expression. In order to determine the most stable and suitable reference genes for the study of rat carotid body during development, six commonly used reference genes, β-actin, RPII (RNA polymerase II, PPIA (peptidyl-proyl-isomerase A, TBP (TATA-box binding protein, GAPDH, and 18s rRNA, were evaluated in two age groups (P0-1 and P14-16 under three environmental oxygen conditions (normoxia, chronic hypoxia and chronic hyperoxia using the three most commonly used software programs, geNorm, NormFinder and BestKeeper. Findings The three programs produced similar results but the reference gene rankings were not identical between programs or experimental conditions. Overall, 18s rRNA was the least stable reference gene for carotid body and, when hyperoxia and/or hypoxia conditions were included, actin was similarly unstable. Conclusions Reference or housekeeping gene expression for qPCR studies of carotid body during postnatal development may vary with developmental stage and environmental conditions. Selection of the best reference gene or combination of reference genes for carotid body development studies should take environmental conditions into account. Two commonly used reference genes, 18s rRNA and actin, may be unsuitable for studies of carotid body maturation, especially if the study

  4. Cerebral hyperperfusion syndrome after carotid angioplasty

    International Nuclear Information System (INIS)

    Milosevic, Z.; Surlan, M.; Zvan, B.; Zaletel, M.

    2002-01-01

    Background. Cerebral hyperperfusion syndrome after carotid endarterectomy is an uncommon but well-defined entity. There are only few reports of ''hyperperfusion injury'' following carotid angioplasty. Case report. We report an unstable arterial hypertension and high-grade carotid stenosis in a 58-year-old, right-handed woman. After a stroke in the territory of middle cerebral artery carotid angioplasty was performed in the patient. Among risk factors, the long lasting arterial hypertension was the most pronounced. Immediately after the procedure, the patient was stable without any additional neurologic deficit. The second day, the patient had an epileptic seizure and CT revealed a small haemorrhage in the left frontal lobe. Conclusions. The combination of a high-grade carotid stenosis and unstable arterial pressure is probably an important prognostic factor in the pathogenesis of hyperperfusion syndrome. (author)

  5. Diagnosis of carotid artery stegnosis

    International Nuclear Information System (INIS)

    Uwatoko, Takeshi; Okada, Yasushi

    2008-01-01

    Carotid Artery Stegnosis (CAS) is an important cause of the crisis of atherothrombotic cerebral infarction. This paper describes diagnosis and evaluation of CAS by echo and MRI/MR angiography (MRA) together with its clinical characteristics. Two hundreds Japanese patients undergone with carotid endarterectomy in authors' hospital are found to have had complications of coronary lesions in 38% and arteriosclerosis obliterans in 13%. Echo is a useful and simple method for detection of dynamic state of CAS and in cerebral infarction, diagnosis to decide whether the plaque is the culprit lesion is important as well as to decide the degree of stegnosis. The lesion is detected through the B mode method and the degree, through the color Doppler imaging; and blood flow rate and its waveform can be evaluated. MRI/MRA has advantages of its objectivity and wide imaging range. The MRI/MRA using various imaging techniques like black-blood method by spin echo or gradient echo modes and fat-suppression combination is advantageous and expectedly to be further developed for evaluation of plaque nature and status leading to therapeutic planning. Thus the degree of stegnosis and vulnerability of the plaque evaluated by echo and MRI/MRA of the cervical artery will be more important for judging the surgical applicability of circulatory reconstruction. (R.T.)

  6. Tensile and compressive properties of fresh human carotid atherosclerotic plaques.

    LENUS (Irish Health Repository)

    Maher, Eoghan

    2009-12-11

    Accurate characterisation of the mechanical properties of human atherosclerotic plaque is important for our understanding of the role of vascular mechanics in the development and treatment of atherosclerosis. The majority of previous studies investigating the mechanical properties of human plaque are based on tests of plaque tissue removed following autopsy. This study aims to characterise the mechanical behaviour of fresh human carotid plaques removed during endarterectomy and tested within 2h. A total of 50 radial compressive and 17 circumferential tensile uniaxial tests were performed on samples taken from 14 carotid plaques. The clinical classification of each plaque, as determined by duplex ultrasound is also reported. Plaques were classified as calcified, mixed or echolucent. Experimental data indicated that plaques were highly inhomogeneous; with variations seen in the mechanical properties of plaque obtained from individual donors and between donors. The mean behaviour of samples for each classification indicated that calcified plaques had the stiffest response, while echolucent plaques were the least stiff. Results also indicated that there may be a difference in behaviour of samples taken from different anatomical locations (common, internal and external carotid), however the large variability indicates that more testing is needed to reach significant conclusions. This work represents a step towards a better understanding of the in vivo mechanical behaviour of human atherosclerotic plaque.

  7. Anomalous external carotid artery-internal carotid artery anastomosis in two patients with proximal internal carotid arterial remnants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hun [Dept. of Neurology, Stroke Center, Myongji Hospital, Goyang (Korea, Republic of); Cho, Young Dae; Kang, Hyun Seung; Kim, Jeong Eun; Han, Moon Hee [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seung Chai [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ahn, Jun Hyong [Dept. of Neurosurgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2015-08-15

    Two angiographic instances of anomalous external carotid artery (ECA) and internal carotid artery (ICA) anastomosis are described, each occurring at the C2-3 level and bearing remnants of proximal ICA. The ICA remnant of one patient (identifiable immediately upon bifurcation of the common carotid artery) was hypoplastic, and that of the other patient was an occluded arterial stump. These features are not typical of non-bifurcating ICA. The occipital artery originated from an anomalous connection in one instance and from the main trunk of the ECA (just past the ECA-ICA connection) in the other.

  8. Cerebral intolerance during flow arrested carotid angioplasty.

    Science.gov (United States)

    St Louis, Myron; Park, Brian D; Dahn, Michael; Bozeman, Patricia

    2012-01-01

    The use of flow arrest as a means of providing cerebral protection during carotid angioplasty offers the advantages of improved efficiency of debris removal and the ability to provide protection under unfavorable (tortuous) anatomic circumstances. However, in contrast to the filtration methods of cerebral protection, this modality requires complete interruption of antegrade carotid artery flow during balloon angioplasty and stent deployment. We report our experience with 9 patients undergoing carotid angioplasty with the Mo.Ma device, which utilizes common and external carotid artery balloon occlusion during the angioplasty procedure. We assessed the clinical outcomes and intraprocedural hemodynamic data. The average duration of carotid occlusion was 8.3 minutes. Of the 9 patients, 2 patients (22%) experienced cerebral intolerance. No stroke occurred in this patient cohort. There appeared to be a poor relationship between procedure intolerance and the presence of significant contralateral stenosis or low carotid back pressure. Furthermore, the incidence of postangioplasty hypotension was not clearly related to cerebral intolerance. Carotid angioplasty with stenting can be safely conducted with flow arrest as an alternative to filter-type cerebral protection devices. However, because cerebral intolerance is not an infrequent occurrence with this approach, clinicians must be cognizant of management strategies for transient cerebral intolerance.

  9. A Comparison of Po2, Pco2, Ph and Bicarbonate in Blood from the Carotid and Coccygeal Arteries of Calves

    OpenAIRE

    Gustin, Pascal; de Groote, A.; Dhem, A. R.; Bakima, M.; Lomba; Lekeux, Pierre

    1988-01-01

    A technique is described for the subcutaneous deviation of the carotid artery into the jugular groove of calves weighing between 90 and 200 kg. This makes sampling arterial blood or chronic cannulation for further experimentation very easy. Values of oxygen tension, carbon dioxide tension, pH and bicarbonate concentration in blood sampled from the ventral coccygeal artery were compared with the values obtained in blood from carotid artery puncture. The high correlations observed indicate that...

  10. Freestanding membrane composed of micro-ring array with ultrahigh sidewall aspect ratio for application in lightweight cathode arrays

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lanlan [State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Liu, Hongzhong, E-mail: hzliu@mail.xjtu.edu.cn [State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Jiang, Weitao, E-mail: wtjiang@mail.xjtu.edu.cn [State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Gao, Wei [Key Laboratory of Mechanics on Western Disasters and Environment, Lanzhou University, Lanzhou 730000 (China); Chen, Bangdao [State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Li, Xin [Department of Microelectronics, Xi’an Jiaotong University, Xi’an 710049 (China); Ding, Yucheng [State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); An, Ningli [Department of Packaging Engineering, Xi’an University of Technology, Xi’an 710048 (China)

    2014-12-15

    Graphical abstract: A freestanding multilayer ultrathin nano-membrane (FUN-membrane) with a micro-ring array (MRA), in which the dimension of each micro-ring is 3 μm in diameter, 2 μm in height and sub-100 nm in sidewall thickness is successfully fabricated, as shown in the SEM image of figure (a). Due to the MRA with ultrahigh aspect ratio of dielectric-metal sidewall, the FUN-membrane can be transferred to either rigid or flexible substrate to be used as the cathode for lightweight display panel, as shown in the schematic of figure (b). - Highlights: • Exploring a new fabrication method for the freestanding ultrathin nano-membrane (FUN-membrane). • FUN-membrane is composed of micro-ring array with ultrahigh aspect ratio of the insulator-metal sidewall. • The sharp metal edge of each micro-ring is preferred to be served as the micro-emitter. - Abstract: A freestanding multilayer ultrathin nano-membrane (FUN-membrane) with a micro-ring array (MRA) is successfully fabricated through the controllable film deposition. Each micro-ring of FUN-membrane is 3 μm in diameter, 2 μm in height and sub-100 nm in sidewall thickness, demonstrating an ultrahigh sidewall aspect ratio of 20:1. In our strategy, a silica layer (200 nm in thickness), a chromium transition layer (5 nm-thick) and a gold layer (40 nm-thick), were in sequence deposited on patterned photoresist. After removal of the photoresist by lift-off process, a FUN-membrane with MRA was peeled off from the substrate, where the gold layer acted as a protecting layer to prevent the MRA from fracture. The FUN-membrane was then transferred to a flexible polycarbonate (PC) sheet coated with indium tin oxide (ITO) layer, which was then used as a flexible and lightweight cathode. Remarkably, the field emission effect of the fabricated FUN-membrane cathode performs a high field-enhancement factor of 1.2 × 10{sup 4} and a low turn-on voltage of 2 V/μm, indicating the advantages of the sharp metal edge of MRA. Due

  11. Freestanding membrane composed of micro-ring array with ultrahigh sidewall aspect ratio for application in lightweight cathode arrays

    International Nuclear Information System (INIS)

    Wang, Lanlan; Liu, Hongzhong; Jiang, Weitao; Gao, Wei; Chen, Bangdao; Li, Xin; Ding, Yucheng; An, Ningli

    2014-01-01

    Graphical abstract: A freestanding multilayer ultrathin nano-membrane (FUN-membrane) with a micro-ring array (MRA), in which the dimension of each micro-ring is 3 μm in diameter, 2 μm in height and sub-100 nm in sidewall thickness is successfully fabricated, as shown in the SEM image of figure (a). Due to the MRA with ultrahigh aspect ratio of dielectric-metal sidewall, the FUN-membrane can be transferred to either rigid or flexible substrate to be used as the cathode for lightweight display panel, as shown in the schematic of figure (b). - Highlights: • Exploring a new fabrication method for the freestanding ultrathin nano-membrane (FUN-membrane). • FUN-membrane is composed of micro-ring array with ultrahigh aspect ratio of the insulator-metal sidewall. • The sharp metal edge of each micro-ring is preferred to be served as the micro-emitter. - Abstract: A freestanding multilayer ultrathin nano-membrane (FUN-membrane) with a micro-ring array (MRA) is successfully fabricated through the controllable film deposition. Each micro-ring of FUN-membrane is 3 μm in diameter, 2 μm in height and sub-100 nm in sidewall thickness, demonstrating an ultrahigh sidewall aspect ratio of 20:1. In our strategy, a silica layer (200 nm in thickness), a chromium transition layer (5 nm-thick) and a gold layer (40 nm-thick), were in sequence deposited on patterned photoresist. After removal of the photoresist by lift-off process, a FUN-membrane with MRA was peeled off from the substrate, where the gold layer acted as a protecting layer to prevent the MRA from fracture. The FUN-membrane was then transferred to a flexible polycarbonate (PC) sheet coated with indium tin oxide (ITO) layer, which was then used as a flexible and lightweight cathode. Remarkably, the field emission effect of the fabricated FUN-membrane cathode performs a high field-enhancement factor of 1.2 × 10 4 and a low turn-on voltage of 2 V/μm, indicating the advantages of the sharp metal edge of MRA. Due to the

  12. Carotid artery stenosis after neck radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shimamura, Munehisa; Hashimoto, Yoichiro; Kasuya, Junji; Terasaki, Tadashi [Kumamoto City Hospital (Japan); Uchino, Makoto

    2000-02-01

    Carotid artery stenosis sometimes occurs after cervical radiotherapy. We report a 70-year-old woman with a history of radiotherapy for thyroid cancer at the age of 28 years. She had no signs and symptoms except the skin lesion at the irradiation site. Duplex ultrasonography revealed heterogeneous plaques showing 50% stenosis of bilateral common carotid arteries. Those lesions were observed within segment of irradiation, where atheromatous plaque usually seldom occurs. These indicated that the carotid stenosis was induced by radiotherapy. Although the efficacy of antiplatelet therapy for radiation-induced plaque is not clear, the plaques remained unchanged for 4 years in spite of aspirin administration. (author)

  13. Thalamic hemorrhage following carotid angioplasty and stenting

    International Nuclear Information System (INIS)

    Friedman, Jonathan A.; Kallmes, David F.; Wijdicks, Eelco F.M.

    2004-01-01

    Carotid angioplasty and stenting (CAS) has emerged as an alternative treatment of carotid stenosis for patients poorly suited for endarterectomy. Intracerebral hemorrhage following carotid revascularization is rare and thought to be related to hyperperfusion injury in most cases. Early experience suggests an increased incidence of hemorrhage following CAS as compared to endarterectomy. We describe a patient who suffered a thalamic hemorrhage following CAS. Because this hemorrhage occurred in a vascular territory unlikely to have been supplied by the treated artery, this case suggests that the mechanism of intracerebral hemorrhage following CAS may in some cases be different from the hyperperfusion hemorrhage classically described following endarterectomy. (orig.)

  14. Carotid artery bypass in acute postendarterectomy thrombosis.

    Science.gov (United States)

    Paty, P S; Darling, R C; Cordero, J A; Shah, D M; Chang, B B; Leather, R P

    1996-08-01

    Carotid endarterectomy has demonstrated excellent results over the past 2 decades with combined stroke mortality of improvement in symptoms in 79% (11 of 14) of the patients and complete resolution in 57% (8 of 14). In long-term follow up (1 to 41 months), there have been no occlusions and one restenosis requiring revision at 11 months. Carotid artery bypass can be performed safely with acceptable results. The use of autogenous venous conduits allows reconstruction with an endothelial lined conduit that may improve results in patients with acute postoperative neurologic deficit secondary to thrombosis of the endarterectomized carotid artery.

  15. Flow diversion in the treatment of carotid injury and carotid-cavernous fistula after transsphenoidal surgery

    Science.gov (United States)

    Lum, Cheemum; Ahmed, Muhammad E; Glikstein, Rafael; dos Santos, Marlise P; Lesiuk, Howard; Labib, Mohamed; Kassam, Amin B

    2015-01-01

    We describe a case of iatrogenic carotid injury with secondary carotid-cavernous fistula (CCF) treated with a silk flow diverter stent placed within the injured internal carotid artery and coils placed within the cavernous sinus. Flow diverters may offer a simple and potentially safe vessel-sparing option in this rare complication of transsphenoidal surgery. The management options are discussed and the relevant literature is reviewed. PMID:26015526

  16. Presentation of a glomus carotid tumor as carotid sinus syndrome with syncopal episodes

    International Nuclear Information System (INIS)

    Dickschas, A.; Harmann, B.; Herzog, T.; Marienhagen, J.

    1987-01-01

    An 80 year old patient was referred to neurology for clarification of her episodes of syncope. A set of radiological examinations indicated a diagnosis of paraganglion of the left carotid bifurcation. Using this case, an attempt is made to provide recommendations concerning the order of step-wise visualization techniques of clarifying glomus carotid tumors. This unusual case also provides an impetus for considering the physiology and pathogenesis of different forms of carotid sinus syndrome. (orig.) [de

  17. Approximate transient and long time limit solutions for the band broadening induced by the thin sidewall-layer in liquid chromatography columns.

    Science.gov (United States)

    Broeckhoven, Ken; Desmet, Gert

    2007-11-16

    Using a combination of both analytical and numerical techniques, approximate analytical expressions have been established for the transient and long time limit band broadening, originating from the presence of a thin disturbed sidewall layer in liquid chromatography columns, including packed, monolithic as well as microfabricated columns. The established expressions can be used to compare the importance of a thin disturbed sidewall layer with that of other radial heterogeneity effects (such as transcolumn packing density variations due to the relief of packing stresses). The expressions are independent of the actual velocity profile inside the layer as long as the disturbed sidewall layer occupies less than 2.5% of the column width.

  18. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito [Kainan Hospital Aichi Prefectural Welfare Federation of Agricultural Cooperatives, Department of Neurosurgery, Aichi (Japan); Miyachi, Shigeru; Hattori, Kenichi [Nagoya University Graduate School of Medicine, Department of Neurosurgery, Nagoya (Japan)

    2006-11-15

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  19. Intracranial carotid anastomosis and partial aplasia of an internal carotid artery

    International Nuclear Information System (INIS)

    Huber, G.

    1980-01-01

    A rare arterial anastomosis between the right and left interal carotid arteries at the base at the skull, with aplasia of the cervical part of the left internal carotid artery is reported. The case is unusual because, in addition to the vascular anomaly of the carotid artery, there is an aneurysm of the anterior communicating artery and bilateral renal cysts. The condition is a complex malformation syndrome caused by defective regression of the third branchial artery. Because of the characteristic angiographic aspects such a case should be called transverse carotid anastomosis. (orig.)

  20. Intracranial carotid anastomosis and partial aplasia of an internal carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Huber, G.

    1980-12-01

    A rare arterial anastomosis between the right and left internal carotid arteries at the base at the skull, with aplasia of the cervical part of the left internal carotid artery is reported. The case is unusual because, in addition to the vascular anomaly of the carotid artery, there is an aneurysm of the anterior communicating artery and bilateral renal cysts. The condition is a complex malformation syndrome caused by defective regression of the third branchial artery. Because of the characteristic angiographic aspects such a case should be called transverse carotid anastomosis.

  1. Resolution of carotid stenosis pre-carotid intervention: A case for selective preoperative duplex ultrasound.

    Science.gov (United States)

    Ali, Abid; Ashrafi, Mohammed; Zeynali, Iraj

    2015-01-01

    Spontaneous resolution of carotid stenosis is a phenomenon that has been described in literature in the past. At present it is not routine practise to scan patients prior to carotid endarterectomy surgery within the UK. A 58 year old female presented to hospital with a history of sudden onset headache and left sided weakness. CT head showed findings in keeping with an acute right MCA territory infarct. A duplex ultrasound scan showed echolucent material in the right internal carotid artery forming a greater than 95% stenosis. The scan was unable to visualise the patency of the vessel distally due to the position of the mandible. The patient was provisionally listed for carotid endarterectomy. An MRA was requested prior to surgery to assess the patency of the distal internal carotid artery. The MRA of the carotids showed normal appearance of the common carotid, internal and vertebral arteries with no definite stenosis. A repeat duplex ultrasound confirmed there was no significant stenosis. The finding of complete resolution of stenosis on MRA was an unexpected event. Had the initial duplex imaging allowed visualisation of the distal vessel patency, our patient would have undergone unnecessary carotid surgery with the associated morbidity and mortality. This case report draws attention to the benefits of selective preoperative scanning, in sparing patients from unnecessary surgery as a result of finding occlusion or resolution of a previously diagnosed carotid stenosis. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    International Nuclear Information System (INIS)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito; Miyachi, Shigeru; Hattori, Kenichi

    2006-01-01

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  3. A new arrangement with nonlinear sidewalls for tanker ship storage panels

    Science.gov (United States)

    Ketabdari, M. J.; Saghi, H.

    2013-03-01

    Sloshing phenomenon in a moving container is a complicated free surface flow problem. It has a wide range of engineering applications, especially in tanker ships and Liquefied Natural Gas (LNG) carriers. When the tank in these vehicles is partially filled, it is essential to be able to evaluate the fluid dynamic loads on tank perimeter. Different geometric shapes such as rectangular, cylindrical, elliptical, spherical and circular conical have been suggested for ship storage tanks by previous researchers. In this paper a numerical model is developed based on incompressible and inviscid fluid motion for the liquid sloshing phenomenon. The coupled BEM-FEM is used to solve the governing equations and nonlinear free surface boundary conditions. The results are validated for rectangular container using data obtained for a horizontal periodic sway motion. Using the results of this model a new arrangement of trapezoidal shapes with quadratic sidewalls is suggested for tanker ship storage panels. The suggested geometric shape not only has a maximum surrounded tank volume to the constant available volume, but also reduces the sloshing effects more efficiently than the existing geometric shapes.

  4. Force Measurement Improvements to the National Transonic Facility Sidewall Model Support System

    Science.gov (United States)

    Goodliff, Scott L.; Balakrishna, Sundareswara; Butler, David; Cagle, C. Mark; Chan, David; Jones, Gregory S.; Milholen, William E., II

    2016-01-01

    The National Transonic Facility is a transonic pressurized cryogenic facility. The development of the high Reynolds number semi-span capability has advanced over the years to include transonic active flow control and powered testing using the sidewall model support system. While this system can be used in total temperatures down to -250Â F for conventional unpowered configurations, it is limited to temperatures above -60Â F when used with powered models that require the use of the high-pressure air delivery system. Thermal instabilities and non-repeatable mechanical arrangements revealed several data quality shortfalls by the force and moment measurement system. Recent modifications to the balance cavity recirculation system have improved the temperature stability of the balance and metric model-to-balance hardware. Changes to the mechanical assembly of the high-pressure air delivery system, particularly hardware that interfaces directly with the model and balance, have improved the repeatability of the force and moment measurement system. Drag comparisons with the high-pressure air system removed will also be presented in this paper.

  5. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  6. Obesity and carotid artery remodeling

    DEFF Research Database (Denmark)

    Kozakova, M; Palombo, C; Morizzo, C

    2015-01-01

    BACKGROUND/OBJECTIVE: The present study tested the hypothesis that obesity-related changes in carotid intima-media thickness (IMT) might represent not only preclinical atherosclerosis but an adaptive remodeling meant to preserve circumferential wall stress (CWS) in altered hemodynamic conditions...... and CCA LD (266 healthy subjects with wide range of body weight (24-159 kg)); (B) longitudinal associations between CCA LD and 3-year IMT progression rate (ΔIMT; 571 healthy non-obese subjects without increased cardiovascular (CV) risk); (C) the impact of obesity on CCA geometry and CWS (88 obese subjects...... without CV complications and 88 non-obese subjects matched for gender and age). RESULTS: CCA LD was independently associated with SV that was determined by body size. In the longitudinal study, baseline LD was an independent determinant of ΔIMT, and ΔIMT of subjects in the highest LD quartile...

  7. Chemical mechanical polishing of BTO thin film for vertical sidewall patterning of high-density memory capacitor

    International Nuclear Information System (INIS)

    Kim, Nam-Hoon; Ko, Pil-Ju; Seo, Yong-Jin; Lee, Woo-Sun

    2006-01-01

    Most high-k materials cannot to be etched easily. Problems such as low etch rate, poor sidewall angle, plasma damage, and process complexity have emerged in high-density DRAM fabrication. Chemical mechanical polishing (CMP) by the damascene process has been used to pattern high-k materials for high-density capacitor. Barium titanate (BTO) thin film, a typical high-k material, was polished with three types of silica slurry having different pH values. Sufficient removal rate with adequate selectivity to realize the pattern mask of tetra-ethyl ortho-silicate (TEOS) film for the vertical sidewall angle was obtained. The changes of X-ray diffraction pattern and dielectric constant by CMP process were negligible. Planarization was also achieved for the subsequent multilevel processes. Our new CMP approach will provide a guideline for effective patterning of high-k materials by CMP

  8. MR plaque imaging of the carotid artery

    International Nuclear Information System (INIS)

    Watanabe, Yuji; Nagayama, Masako

    2010-01-01

    Atherosclerotic carotid plaque represents a major cause of cerebral ischemia. The detection of vulnerable plaque is important for preventing future cardiovascular events. The key factors in advanced plaque that are most likely to lead to patient complications are the condition of the fibrous cap, the size of the necrotic core and hemorrhage, and the extent of inflammatory activity within the plaque. Magnetic resonance (MR) imaging has excellent soft tissue contrast and can allow for a more accurate and objective estimation of carotid wall morphology and plaque composition. Recent advances in MR imaging techniques have permitted serial monitoring of atherosclerotic disease evolution and the identification of intraplaque risk factors for accelerated progression. The purpose of this review article is to review the current state of techniques of carotid wall MR imaging and the characterization of plaque components and surface morphology with MR imaging, and to describe the clinical practice of carotid wall MR imaging for the determination of treatment plan. (orig.)

  9. Ophthalmic masquerades of the atherosclerotic carotids

    Directory of Open Access Journals (Sweden)

    Anupriya Arthur

    2014-01-01

    Full Text Available Patients with carotid atherosclerosis can present with ophthalmic symptoms. These symptoms and signs can be due to retinal emboli, hypoperfusion of the retina and choroid, opening up of collateral channels, or chronic hypoperfusion of the globe (ocular ischemic syndrome. These pathological mechanisms can produce many interesting signs and a careful history can bring out important past symptoms pointing toward the carotid as the source of the patient′s presenting symptom. Such patients are at high risk for an ischemic stroke, especially in the subsequent few days following their first acute symptom. It is important for clinicians to be familiar with these ophthalmic symptoms and signs caused by carotid atherosclerosis for making an early diagnosis and to take appropriate measures to prevent a stroke. This review elaborates the clinical features, importance, and implications of various ophthalmic symptoms and signs resulting from atherosclerotic carotid artery disease.

  10. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...

  11. Diagnosis Of The Risk For Carotid Artery Stenos Based On Thermal Model In Infrared Images

    Directory of Open Access Journals (Sweden)

    Fatemeh Valipoori Goodarzi

    2017-02-01

    Full Text Available Background and purpose: Ischemic stroke is the third leading cause of death and a common cause of hospitalization in the United States of America and is also an important factor for Inability of patients and carotid stenos is one of the most important factors in creating it. Now, Imaging studies include: Angiography, MRI, CT scan and Doppler ultrasonography , are used to detect carotid artery stenos that is one of the most important causes of ischemic stroke. However, each method has unique advantages and disadvantages, that many of them will have a compromise between performance and accuracy versus easy usage and cost considerations. In contrast, in this paper, thermography is used as a non-invasive and cost effective to detect carotid artery Stenos and thus the risk of stroke. Materials and methods: This study is done on a series of thermal images obtained from the Clinical Center in California. In this imaging, the automatic detection of carotid artery stenos and thus Risk for stroke was done, based on: (1 the difference of average temperature between the right and left carotid arteries in the neck (2 The presence or absence of internal and external carotid arteries. Results: In this study, with the survey conducted by a specialist brain of patients had been previously, the accuracy of this work is confirmed. the techniques and points that are Experimental and  scientifically based  and obtained in this study, can help to doctors for Early detection of Artery disease, based on analysis of thermal images . Conclusion: The method presented in this paper is considered as a non-invasive and cost-effective method that automatically operates to detect the carotid arteries and prevent the Risk for stroke.

  12. Hemodynamic significance of internal carotid artery disease

    DEFF Research Database (Denmark)

    Schroeder, T

    1988-01-01

    Neurologic symptoms in the region of an internal carotid artery stenosis are considered to be embolic in most instances. Only in a subgroup has carotid occlusive disease with impairment of the collateral supply, caused a state of hemodynamic failure with marked reduction of perfusion pressure...... stenosis. This is considered a result of chronic low perfusion pressure with subsequent loss of autoregulation, and autoregulatory control is first regained after some days.(ABSTRACT TRUNCATED AT 400 WORDS)...

  13. Angiographic diagnosis of the carotid artery pseudoaneurysm

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Tan Yinghui; Li Zhongyu; Zhou Zheng

    2004-01-01

    Objective: To create a further understanding of the angiographic features of the carotid artery pseudoaneurysm (CAPA) and to explore the clinical diagnostic value of angiography. Methods: Sixteen cases of CAPA with clinical and angiographic data were analyzed retrospectively. The angiographic appearances in all of the patients were observed dynamically and precisely with a double blind method by two experienced radiologists together and formed a consensus interpretation. Results: Angiography provided a definite diagnosis for all cases. The parent arteries included the common carotid artery (1 case), common carotid artery bifurcation (9 cases), internal carotid artery (5 cases) and external carotid artery (1 case). The angiographic features of the CAPA were: All cases showed the contrast media retension in the aneurysms; turbulent flow within aneurysm in 9 cases; the 'jetting sign' at the leak of the parent artery in 7 cases; increase angulation of the bifurcation of internal and external carotid arteries in 12 cases. Conclusions: Angiography is the most valuable examination method in diagnosis of CAPA, and it can not only provide definite diagnosis, but also play an important role in selection of therapeutic plan. (authors)

  14. Carotid chemoreceptor development and neonatal apnea.

    Science.gov (United States)

    MacFarlane, Peter M; Ribeiro, Ana P; Martin, Richard J

    2013-01-01

    The premature transition from fetal to neonatal life is accompanied by an immature respiratory neural control system. Most preterm infants exhibit recurrent apnea, resulting in repetitive oscillations in O(2) saturation (intermittent hypoxia, IH). Numerous factors are likely to play a role in the etiology of apnea including inputs from the carotid chemoreceptors. Despite major advances in our understanding of carotid chemoreceptor function in the early neonatal period, however, their contribution to the initiation of an apneic event and its eventual termination are still largely speculative. Recent findings have provided a detailed account of the postnatal changes in the incidence of hypoxemic events associated with apnea, and there is anecdotal evidence for a positive correlation with carotid chemoreceptor maturation. Furthermore, studies on non-human animal models have shown that chronic IH sensitizes the carotid chemoreceptors, which has been proposed to perpetuate the occurrence of apnea. An alternative hypothesis is that sensitization of the carotid chemoreceptors could represent an important protective mechanism to defend against severe hypoxemia. The purpose of this review, therefore, is to discuss how the carotid chemoreceptors may contribute to the initiation and termination of an apneic event in the neonate and the use of xanthine therapy in the prevention of apnea. Published by Elsevier B.V.

  15. Angiographic patterns of carotid-cavernous fistulas

    International Nuclear Information System (INIS)

    Georgieva, G.; Jekova, M.; Genov, P.; Hadjidekov, V.

    2006-01-01

    Full text: The aim of the study is to present our experience in angiographic evaluation of carotid-cavernous fistulas. 8 patients with carotid-cavernous fistula (6 men and 2 women, range of age from 15 to 62) are included in the study out of all undergone cerebral angiography for a four year period (1996 - 2000). All patients underwent CT brain examination, two out of 8 - MRI. Visualization of ipsi- and contra lateral cavernous sinus and ophthalmic vein dilatation are assessed. In all cases the communication between the internal carotid artery and the cavernous sinus has been assessed as direct. Near simultaneous visualization of the home internal carotid artery, the dilated ipsilateral cavernous sinus and dilated superior ophthalmic vein is found in 2 patients, simultaneous visualization of both cavernous sinuses - in two. In 1 patient the early visualization of the cavernous sinus through the fistula enabled visualization of ipsilateral main internal carotid artery from the contra lateral circulation through the communicating arteries.In 1 excessive contralateral cavernous sinus and contralateral superior ophthalmic vein dilatation is detected. In other 1 excessive flow to dilated ipsilateral cavernous sinus lead insufficient circulation in distal vessels. Digital subtraction Angiography remains the most suitable imaging method in carotid-cavernous fistula assessment regarding type of communication and level of following vessels morphology changes

  16. Sidewall Covalent Functionalization of Single Wall Carbon Nanotubes through C-N Bond Forming Reactions of Fluoronanotubes with Urea, Guanidine and Thiourea (Preprint)

    National Research Council Canada - National Science Library

    Pulikkathara, Merlyn X; Khabashesku, Valery N

    2007-01-01

    ...) as starting materials in the reactions with either urea, thiourea, or guanidine. Through these reactions, the derivatives with terminal amide and heteroamide groups on the nanotube sidewalls have been prepared...

  17. [CHANGES OF CAROTID AND VERTEBRAL ARTERIES IN PATENTS WITH ARTERIAL HYPERTENSION AND HEPATOBILIARY PATHOLOGY].

    Science.gov (United States)

    Polyakov, V Ya; Nikolaev, Yu A; Pegova, S V; Matsievskaya, T R; Obukhov, I V

    2016-01-01

    The study included 1172 patients (410 men and 762 women) at the mean age of 60.3 ± 10.4 years with grade I-II (stage I-II) arterial hypertension (AH) admitted to the clinic of Institute of Experimental Medicine. The patients were divided into 2 groups based on the results of clinical and laboratory diagnostics. Group 1 (n = 525) included patients with AH and hepatobiliary system (HBS) diseases, group 2 (n = 647) patients with AH without HBS diseases. The patients group 1 had a thicker intima-media complex of carotid arteries, higher peak systolic bloodflow rate in the internal and vertebral carotid arteries, more pronounced coiling of internal carotid arteries than patients of group 2. Patients with AH and HBS diseases exhibited correlation between bloodflow rate in external carotid arteries and atherogenicity coefficient. Duplex scanning of neck vessels of in patients with AH without HBS diseases revealed peculiar changes of the intima-media thickness and hemodynamically significant changes of the blood flow in the internal carotid arteries that may be of prognostic value in this nosological syntropy and require the personified approach to diagnostics, treatment, and prevention of these conditions.

  18. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Early control of distal internal carotid artery during carotid endarterectomy: does it reduce cerebral microemboli?

    Science.gov (United States)

    Mommertz, G; Das, M; Langer, S; Koeppel, T A; Krings, T; Mess, W H; Schiefer, J; Jacobs, M J

    2010-06-01

    According to the results of the large trials on carotid endarterectomy (CEA), this type of surgery is only warranted if perioperative mortality and morbidity are kept considerably low. Less attention has been paid to methods of cerebral protection during CEA, although intraoperative transcranial Doppler (TCD) can visualise intracerebral microemboli (MES) during routine carotid dissection, although MES occur throughout the CEA, only those during dissection are related to neurological outcome. Prevention of MES by means of early control of the distal internal carotid artery dislodging from the carotid artery plaque during dissection is very likely the mechanism behind an eventual benefit from this approach. Hence, the amount of MES might serve as a surrogate parameter for the risk of periprocedural neurological events. So, the aim of the present study was to evaluate whether early control of the distal carotid artery during CEA is capable of reducing the number of MES by means of a prospective randomised trial. Twenty-eight patients (29 procedures) could be prospectively included in our study. Before surgery we randomly assigned the patients to two groups: group A (N.=12): CEA by means of early control of the distal internal carotid artery; group B (N.=17): CEA with dissection of the total carotid bifurcation before clamping the arteries. Periprocedurally, we continuously monitored the cerebral blood flow in the ipsilateral middle cerebral artery by means of TCD. Pre- and postoperative morbidity were independently verified by a neurologist control of the distal internal carotid artery did not reduce the occurrence of MES during dissection of the carotid bifurcation. Also, the total number of MES throughout the procedure and postoperatively was comparable between both groups. The procedure related times as well as the clinical outcome did not differ significantly. Thus, early control of the distal internal carotid artery has got no advantage but also no disadvantage

  20. Radiation-induced carotid artery atherosclerosis

    International Nuclear Information System (INIS)

    Gujral, Dorothy M.; Chahal, Navtej; Senior, Roxy; Harrington, Kevin J.; Nutting, Christopher M.

    2014-01-01

    Purpose: Carotid arteries frequently receive significant doses of radiation as collateral structures in the treatment of malignant diseases. Vascular injury following treatment may result in carotid artery stenosis (CAS) and increased risk of stroke and transient ischaemic attack (TIA). This systematic review examines the effect of radiotherapy (RT) on the carotid arteries, looking at the incidence of stroke in patients receiving neck radiotherapy. In addition, we consider possible surrogate endpoints such as CAS and carotid intima-medial thickness (CIMT) and summarise the evidence for radiation-induced carotid atherosclerosis. Materials and methods: From 853 references, 34 articles met the criteria for inclusion in this systematic review. These papers described 9 studies investigating the incidence of stroke/TIA in irradiated patients, 11 looking at CAS, and 14 examining CIMT. Results: The majority of studies utilised suboptimally-matched controls for each endpoint. The relative risk of stroke in irradiated patients ranged from 1.12 in patients with breast cancer to 5.6 in patients treated for head and neck cancer. The prevalence of CAS was increased by 16–55%, with the more modest increase seen in a study using matched controls. CIMT was increased in irradiated carotid arteries by 18–40%. Only two matched-control studies demonstrated a significant increase in CIMT of 36% and 22% (p = 0.003 and <0.001, respectively). Early prospective data demonstrated a significant increase in CIMT in irradiated arteries at 1 and 2 years after RT (p < 0.001 and <0.01, respectively). Conclusions: The incidence of stroke was significantly increased in patients receiving RT to the neck. There was a consistent difference in CAS and CIMT between irradiated and unirradiated carotid arteries. Future studies should optimise control groups

  1. Treatment of carotid-siphon aneurysms by using willis stent-graft: an angiographic and histopathologic study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Xie Jian; Tan Huaqiao; Cheng Yingsheng; Wang Jianbo

    2010-01-01

    Objective: To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months. Methods: Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs (group A) and 12 carotid siphon aneurysms in another twelve dogs (group B). A Willis stent-graft was implanted in each aneurysm. Angiography was performed immediately after the procedure and 1, 3, 6 and 12 months after the implantation to investigate the aneurysm isolation, endoleak, stent angulation, and the patency or restenosis of the parent artery. Light and scanning electronic microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress of the stent-loaded arterial segment. Results: In group B, postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated. Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared, one parent artery became occluded and three parent arteries developed mild stenosis (< 50%). In group A, occlusion of parent artery was seen in one and mild stenosis (< 50%) in 2 cases. Electronic microscopy revealed new intima formation in all stents, and all aneurysmal sacs were filled with thrombi. In group B, the endothelialization process was not completed until 12 months after the stent implantation, and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation. Conclusion: It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft. The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel. (authors)

  2. Carotid Atherosclerosis and Cognitive Impairment in Nonstroke Patients

    Directory of Open Access Journals (Sweden)

    Wei-Hong Chen

    2017-01-01

    Conclusions: Carotid atherosclerosis can be used to predict the risk of cognitive impairment. Furthermore, diagnosing and treating carotid atherosclerosis at early stage might help clinicians prevent and treat vascular cognitive impairment in nonstroke patients.

  3. Cardiac risk assessment before carotid endarterectomy

    International Nuclear Information System (INIS)

    Rabee, Hussein M.M.

    2000-01-01

    Preoperative cardiac assessment is an essential step to identify the patients at risk, optimize any dysfunction, anticipate perioperative and postoperative problems and plan special management. Carotid endarterectomy (CEA) has become one of the most commonly performed vascular procedures in Western countries. The awareness of the potential beneficial role and hazards of CEA is not proportionate to the magnitude of this problem in our countries, not only among patients, but also among the medical disciplines. This report is a retrospective analysis of the prevalence of coronary artery diseases among 442 patients who were referred to the Division of Vascular Surgery at the King Khalid University Hospital in Riyadh, Saudi Arabia with suspicion of carotid artery disease. Eighty-two patients proved to have significant carotid artery stenosis and had thorough preoperative cardiac assessment by senior cardiologist. All cases had clinical assessment and ECG, 66 cases had echocardiogram examination, 44 had Dipyridamole Thallium-scan and 12 had coronary angiogram. Sixty-eight patients underwent 76 carotid endarterectomy. Four of them had MI and only one case died during preoperative period. This study shows that cardiac screening studies have a potential role in the candidates for carotid surgery in influencing the decision to operate and intensify of perioperative monitoring and care. We believe that the teamwork should involve vascular surgeons, cardiologist and anesthetist to manage such critical patients properly. (author)

  4. A Rare Diabetic Autonomic Neuropathy: Carotid Sinus Hypersensitivity

    Directory of Open Access Journals (Sweden)

    Ahmet Kaya

    2016-03-01

    Full Text Available Carotid sinus hypersensitivity is a common cause of fainting and falls in the elderly, and can be diagnosed by carotid sinus massage. We present a 67-year-old diabetic man who was admitted with hyperglycemia. During thyroid examination, clouding of consciousness occurred with unilateral palpation. Asystole was documented for 4.8 seconds and suspected for 7 seconds upon carotid sinus massage. A cardioverter defibrillator was implanted. Carotid sinus hypersensitivity should be kept in mind when examining diabetic patients.

  5. Costs of secondary prevention of stroke by carotid endarterectomy

    DEFF Research Database (Denmark)

    Hædersdal, Carsten; Sørensen, Mette; Olsen, Tom Skyhøj

    2012-01-01

    We estimated the costs to the Danish National Health Service of preventing stroke due to carotid artery stenosis by carotid endarterectomy (CEA), including costs of identifying patients, Doppler ultrasound (DUS) examination and CEA.......We estimated the costs to the Danish National Health Service of preventing stroke due to carotid artery stenosis by carotid endarterectomy (CEA), including costs of identifying patients, Doppler ultrasound (DUS) examination and CEA....

  6. Role of carotid duplex imaging in carotid screening programmes – an overview

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Background Stroke is the third most common cause of death in the UK and the largest single cause of severe disability. Each year more than 110,000 people in England suffer from a stroke which costs the National Health Service (NHS over GBP2.8 billion. Thus, it is imperative that patients at risk be screened for underlying carotid artery atherosclerosis. Aim To assess the role of carotid ultrasound in different carotid screening programmes. Methods A literature overview was carried out by using PubMed search engine, to identify different carotid screening programmes that had used ultrasound scan as a screening tool. Results It appears that the carotid ultrasound is an effective method for screening carotid artery disease in community as it effectively predicts the presence of stenosis with high accuracy. There is a need for primary care to recommend high risk patients for regular screening, to reduce stroke and transient ischemic attack (TIA related morbidity and mortality. Conclusion Screening programmes using carotid ultrasonography contribute to public health awareness and promotion which in long term could potentially benefit in disease prevention and essentially promote better standards of healthcare.

  7. [Risk factors of rupture of internal carotid artery during surgical resection of carotid body tumor].

    Science.gov (United States)

    Li, Y H; Wang, J S; Yao, C; Chang, G Q; Yin, H H; Li, S Q; Lü, W M; Hu, Z J; Wang, S M

    2017-06-13

    Objective: To investigate risk factors of rupture of internal carotid artery resection during carotid body tumor resection and to summarize our treatment experience. Methods: During the period from 1991 to 2016, rupture of internal carotid artery occurred in 27 patients (28 tumors) during surgical resection of carotid body tumor in the First Affiliated Hospital of Sun Yat-sen University. Their clinical and follow-up data were retrospectively collected and analyzed. For all patients underwent surgical resection during this period, Logistic regression analysis was used to investigate the risk factors of intraoperative rupture of internal carotid artery. Results: Of these 28 tumors, there were 15 (53.6%) tumors with diameter≥5 cm and 20 (71.4%) Shamblin Ⅲ tumors. Intraoperatively, shunt was applied for 8 (28.6%) cases. Thirteen (46.4%) patients underwent ligation of external carotid artery, while 2 (7.1%) patients accepted resection of cranial nerves. Direct closure/patchplasty, autologous vessels or graft reconstruction was used in 16, 10 and 2 cases, respectively. Postoperatively, stroke occurred in 4(14.3%) cases and cranial nerve deficit in 15 (53.6%) cases. During a median length of 36 (14-125) months, cranial nerve deficit persisted in 5 cases. Follow-up radiologic examination indicated 3 (10.7%) cases of targeted vessel occlusion. However, no new-onset stroke was identified. Among all patients underwent surgical resection of carotid body tumor, female ( OR =3.650, P =0.012), age≤25 years old ( OR =3.710, P =0.013) and Shamblin Ⅲ tumor ( OR =4.631, P =0.008) increase the risks of intraoperative carotid artery rupture. Conclusions: Shamblin Ⅲ tumor is the predictor of rupture of internal carotid artery. Intraoperative, properly increased blood pressure, intraoperative heparinization and use of shunt for those cases without well-compensated cranial collateral arteries are likely to decreasing the incidence of stroke.

  8. Carotid angioplasty and stenting for symptomatic carotid kinking combined with stenosis

    Directory of Open Access Journals (Sweden)

    JIANG Xue-li

    2013-03-01

    Full Text Available Background Carotid endarterectomy (CEA is currently the preferred treatment for severe carotid kinking and stenosis. Kinking is generally believed to be a relative contraindication for endovascular stent placement. This article aims to study the necessity, feasibility and security of carotid angioplasty and stenting (CAS for symptomatic carotid kinking combined with stenosis, and summarize clinical experience of this disease according to therapeutic results. Methods Twenty-two cases with symptomatic carotid kinking and high-grade stenosis demonstrated by digital subtraction angiography (DSA were performed CAS. Their clinical manifestations, imaging features, procedure safety and follow-up data were collected and retrospectively analyzed. All patients understood CEA and voluntarily received CAS. Results Twenty-two cases with carotid kinking and stenosis were all successfully performed CAS (the success rate was 100% without stent-related disability or mortality. Twenty-four self-expandable stents were implanted. The mean degree of stenosis was reduced from 85.63%before stenting to 11.25% after stenting and the angles of kinking were improved from 120° (Metz' category. During the period of hospitalization, no transient ischemic attack (TIA or cerebral infarction occurred, and the clinical symptoms and signs of ischemia, such as dizziness and headache, were improved or disappeared. Besides, no permenant complications or deaths happened. All cases were followed up from 6 to 72 months, among whom 1 patient experienced contralateral carotid TIA, and 2 patients experienced ipsilateral carotid TIA (one indicated aspirin resistance in platelet aggregation test and the other showed restenosis in DSA. Computed tomography angiography (CTA of 10 patients and Duplex scan of 7 patients during the follow-up demonstrated carotid in good morphology and fluent blood flow, without kinking or restenosis. Conclusion CAS is a feasible and safe therapeutic method and

  9. Apolipoprotein E and carotid artery atherosclerosis - The Rotterdam study

    NARCIS (Netherlands)

    Slooter, AJC; Bots, ML; Havekes, LM; del Sol, AI; Cruts, M; Grobbee, DE; Hofman, A; Van Broeckhoven, C; Witteman, JCM; van Duijn, CM

    Background and Purpose-Carotid artery atherosclerosis is a strong predictor for future stroke. It is yet unclear whether the apolipoprotein E polymorphism (APOE) is related to atherosclerosis in the carotid arteries. The aim of the present study was to investigate the role of APOE in carotid artery

  10. Three-dimensional carotid ultrasound plaque texture predicts vascular events

    DEFF Research Database (Denmark)

    van Engelen, Arna; Wannarong, Thapat; Parraga, Grace

    2014-01-01

    BACKGROUND AND PURPOSE: Carotid ultrasound atherosclerosis measurements, including those of the arterial wall and plaque, provide a way to monitor patients at risk of vascular events. Our objective was to examine carotid ultrasound plaque texture measurements and the change in carotid plaque text...

  11. Agenesis of internal carotid artery associated with congenital anterior hypopituitarism

    International Nuclear Information System (INIS)

    Moon, W.-J.; Porto, L.; Lanfermann, H.; Zanella, F.E.; Weis, R.

    2002-01-01

    We report a rare case of unilateral agenesis of the internal carotid artery in association with congenital anterior hypopituitarism. The collateral circulation is supplied by a transsellar intercavernous anastomotic vessel connecting the internal carotid arteries. These abnormalities are well depicted on MRI and MRA. The agenesis of the internal carotid artery may explain the pathogenesis of some of congenital anterior hypopituitarism. (orig.)

  12. Risk of Carotid Stroke after Chiropractic Care

    DEFF Research Database (Denmark)

    Cassidy, J. David; Boyle, Eleanor; Côté, Pierre

    2017-01-01

    Background Chiropractic manipulation is a popular treatment for neck pain and headache, but may increase the risk of cervical artery dissection and stroke. Patients with carotid artery dissection can present with neck pain and/or headache before experiencing a stroke. These are common symptoms seen...... by both chiropractors and primary care physicians (PCPs). We aimed to assess the risk of carotid artery stroke after chiropractic care by comparing association between chiropractic and PCP visits and subsequent stroke. Methods A population-based, case-crossover study was undertaken in Ontario, Canada. All...... incident cases of carotid artery stroke admitted to hospitals over a 9-year period were identified. Cases served as their own controls. Exposures to chiropractic and PCP services were determined from health billing records. Results We compared 15,523 cases to 62,092 control periods using exposure windows...

  13. Freestanding membrane composed of micro-ring array with ultrahigh sidewall aspect ratio for application in lightweight cathode arrays

    Science.gov (United States)

    Wang, Lanlan; Liu, Hongzhong; Jiang, Weitao; Gao, Wei; Chen, Bangdao; Li, Xin; Ding, Yucheng; An, Ningli

    2014-12-01

    A freestanding multilayer ultrathin nano-membrane (FUN-membrane) with a micro-ring array (MRA) is successfully fabricated through the controllable film deposition. Each micro-ring of FUN-membrane is 3 μm in diameter, 2 μm in height and sub-100 nm in sidewall thickness, demonstrating an ultrahigh sidewall aspect ratio of 20:1. In our strategy, a silica layer (200 nm in thickness), a chromium transition layer (5 nm-thick) and a gold layer (40 nm-thick), were in sequence deposited on patterned photoresist. After removal of the photoresist by lift-off process, a FUN-membrane with MRA was peeled off from the substrate, where the gold layer acted as a protecting layer to prevent the MRA from fracture. The FUN-membrane was then transferred to a flexible polycarbonate (PC) sheet coated with indium tin oxide (ITO) layer, which was then used as a flexible and lightweight cathode. Remarkably, the field emission effect of the fabricated FUN-membrane cathode performs a high field-enhancement factor of 1.2 × 104 and a low turn-on voltage of 2 V/μm, indicating the advantages of the sharp metal edge of MRA. Due to the rational design and material versatility, the FUN-membrane thus could be transferred to either rigid or flexible substrate, even curved surface, such as the skin of bio-robot's arm or leg. Additionally, the FUN-membrane composed of MRA with extremely high aspect ratio of insulator-metal sidewall, also provides potential applications in optical devices, lightweight and flexible display devices, and electronic eye imagers.

  14. Carotid endarterectomy in patients with occlusion of the contralateral carotid artery. Perioperative risk and late results

    DEFF Research Database (Denmark)

    Sillesen, H; Schroeder, T; Rasmussen, L

    1987-01-01

    severe strokes when compared to patients with only minor reduction in CPP. In addition, the internal carotid artery blood flow following endarterectomy was significantly higher in the low pressure group (P less than 0.02). No patients were lost during follow-up, for a mean of 34 months. The cumulative....... Compared with a complication rate of about 5% previously reported from this institution, this clearly indicates contralateral carotid occlusion as a major risk factor in carotid surgery. Though not statistically significant, patients with severely reduced cerebral perfusion pressure (CPP) had suffered more...

  15. Simulation of a Smith-Purcell free-electron laser with sidewalls: Copious emission at the fundamental frequency

    International Nuclear Information System (INIS)

    Donohue, J. T.; Gardelle, J.

    2011-01-01

    The two-dimensional theory of the Smith-Purcell free-electron laser of Andrews and Brau [H. L. Andrews and C. A. Brau, Phys. Rev. ST Accel. Beams 7, 070701 (2004)] predicts that coherent Smith-Purcell radiation can occur only at harmonics of the frequency of the evanescent wave that is resonant with the beam. A particle-in-cell simulation shows that in a three-dimensional context, where the lamellar grating has sidewalls, coherent Smith-Purcell radiation can be copiously emitted at the fundamental frequency, for a well-defined range of beam energy.

  16. Observation of copious emission at the fundamental frequency by a Smith-Purcell free-electron laser with sidewalls

    International Nuclear Information System (INIS)

    Gardelle, J.; Modin, P.; Donohue, J. T.

    2012-01-01

    An experiment at microwave frequencies confirms the recent prediction that a Smith-Purcell [S. J. Smith and E. M. Purcell, Phys. Rev. 92, 1069 (1953)] free-electron laser equipped with sidewalls can emit radiation at the frequency of the surface wave. The power output is considerably greater than for the previously observed emission at the second harmonic, in agreement with three-dimensional simulations. The dependence of frequency on beam energy and emission angle is in good agreement with three-dimensional theory and simulations. Provided that a reduction in scale can be achieved, a path is open to coherent Smith-Purcell radiation at terahertz frequency.

  17. Haemodynamic evaluation of carotid artery disease

    DEFF Research Database (Denmark)

    Sillesen, H; Schroeder, T

    1989-01-01

    Cerebral ischaemia in the region of an internal carotid artery (ICA) stenosis may be caused by embolism or cerebral hypoperfusion. A severe ICA stenosis may be well compensated by collateral blood supply, however, in some patients the capacity of the collateral blood supply is insufficient. Studies...... evaluating therapeutic modalities or natural history of carotid artery disease should therefore include a test capable of assessing cerebral haemodynamics. However, most studies, invasive as well as non-invasive, have focused on the ability of the test to diagnose the ICA lesions itself, rather than...

  18. Carotid body (Thermoreceptors, sympathetic neural activation, and cardiometabolic disease

    Directory of Open Access Journals (Sweden)

    Rodrigo Iturriaga

    Full Text Available The carotid body (CB is the main peripheral chemoreceptor that senses the arterial PO2, PCO2 and pH. In response to hypoxemia, hypercapnia and acidosis, carotid chemosensory discharge elicits reflex respiratory, autonomic and cardiovascular adjustments. The classical construct considers the CB as the main peripheral oxygen sensor, triggering reflex physiological responses to acute hypoxemia and facilitating the ventilatory acclimation to chronic hypoxemia at high altitude. However, a growing body of experimental evidence supports the novel concept that an abnormally enhanced CB chemosensory input to the brainstem contributes to overactivation of the sympathetic nervous system, and consequent pathology. Indeed, the CB has been implicated in several diseases associated with increases in central sympathetic outflow. These include hypertension, heart failure, sleep apnea, chronic obstructive pulmonary disease and metabolic syndrome. Indeed, ablation of the CB has been proposed for the treatment of severe and resistant hypertension in humans. In this review, we will analyze and discuss new evidence supporting an important role for the CB chemoreceptor in the progression of autonomic and cardiorespiratory alterations induced by heart failure, obstructive sleep apnea, chronic obstructive pulmonary disease and metabolic syndrome.

  19. Epigenetic Regulation of Carotid Body Oxygen Sensing: Clinical Implications.

    Science.gov (United States)

    Nanduri, Jayasri; Prabhakar, Nanduri R

    2015-01-01

    Recurrent apnea with intermittent hypoxia (IH) is a major clinical problem in infants born preterm. Recent epidemiological studies showed that adults who were born preterm exhibit increased incidence of sleep-disordered breathing and hypertension. Thus, apnea of prematurity predisposes individuals to autonomic dysfunction in adulthood. Experimental studies showed that adult rats exposed to IH as neonates exhibit augmented carotid body and adrenal chromaffin cells (AMC) response to hypoxia and irregular breathing with apneas and hypertension. The enhanced hypoxic sensitivity of the carotid body and AMC in adult rats exposed to neonatal IH was associated with increased oxidative stress, decreased expression of genes encoding anti-oxidant enzymes, and increased expression of pro-oxidant enzymes. Epigenetic mechanisms including DNA methylation leads to long-term changes in gene expression. The decreased expression of the Sod2 gene, which encodes the anti-oxidant enzyme, superoxide dismutase 2, was associated with DNA hypermethylation of a single CpG dinucleotide close to the transcription start site. Treating neonatal rats with decitabine, an inhibitor of DNA methylation, during IH exposure prevented the oxidative stress, enhanced hypoxic sensitivity, and autonomic dysfunction in adult rats. These findings suggest that epigenetic mechanisms, especially DNA methylation contributes to neonatal programming of hypoxic sensitivity and the ensuing autonomic dysfunction in adulthood.

  20. Mixing in the human carotid artery during carotid drug infusion studied with PET

    International Nuclear Information System (INIS)

    Junck, L.; Koeppe, R.A.; Greenberg, H.S.

    1989-01-01

    The safety and efficacy of drug infusion into the carotid artery require adequate mixing of the infused solution with carotid blood. Using positron emission tomography (PET), we studied the mixing of solutions infused into the human carotid artery in seven patients by analyzing the distribution of [15O]H2O infused into the carotid artery and by vein. At four infusion rates ranging from 0.5 to 10 ml/min, the variability in distribution averaged 16.5-17.8% among the pixels in a large volume of interest, without dependence on the infusion rate. The overall correlation between [15O]H2O influx with arterial infusion and [15O]H2O influx with venous injection was 0.78-0.82 at the four infusion rates, with no trend toward higher correlations at the faster infusion rates. The distribution into the anterior, middle, and posterior cerebral artery territories differed from distribution throughout the entire carotid territory by an average of 6.2-9.6% at the four infusion rates, with no trend toward smaller differences at the faster infusion rates. Infusions performed into a vinyl tube simulating the carotid artery indicated that at 0.5 ml/min, the velocity of fluid exiting the catheter makes no apparent contribution to mixing. We conclude that with infusions at the carotid bifurcation, mixing in the human carotid artery is complete or nearly complete over a wide range of infusion rates. The mixing appears to result from the patterns of blood flow within the artery, and not from jet effects at the catheter tip

  1. Stenosis of calcified carotid artery detected on Panoramic Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, So Yang; Oh, Won Mann; Yoon, Suk Ja; Yoon, Woong; Lee, Jae Seo; Kang, Byung Cheol [School of Dentistry, Chonnam National University, Seoul (Korea, Republic of); Palomo, Juan M. [Department of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland (United States)

    2009-09-15

    This study aimed to investigate the luminal stenosis of the internal carotid artery with calcification detected on panoramic radiographs. This study used fifty carotid arteries of 36 dental patients whose panoramic radiograph and computed tomography angiography (CTA) revealed the presence of carotid artery calcification. A neuroradiologist interpreted CTA to determine the degree of stenosis of the internal carotid arteries. The degree of stenosis was stratified in four stages; normal (no stenosis), mild stenosis (1-49%), moderate stenosis (50-69%) and severe stenosis (70-99%). Among the fifty carotid arteries with calcification detected on both panoramic radiography and CTA, 20 carotid arteries (40%) were normal, 29 carotid arteries (18%) had mild stenosis, 1 carotid artery (2%) had moderate stenosis, and there was none with severe stenosis. Sixty percent of the carotid arteries with calcification detected on both panoramic radiography and CTA had internal luminal stenosis, and two percent had moderate stenosis. When carotid atheroma is detected on panoramic radiograph, it is possible that the dental patient has luminal stenosis of the internal carotid artery.

  2. Stroke prevention-surgical and interventional approaches to carotid stenosis

    Directory of Open Access Journals (Sweden)

    Kumar Rajamani

    2013-01-01

    Full Text Available Extra cranial carotid artery stenosis is an important cause of stroke, which often needs treatment with carotid revascularization. To prevent stroke recurrence, carotid endarterectomy (CEA has been well-established for several decades for symptomatic high and moderate grade stenosis. Carotid stenting is a less invasive alternative to CEA and several recent trials have compared the efficacy of the 2 procedures in patients with carotid stenosis. Carotid artery stenting has emerged as a potential mode of therapy for high surgical risk patients with symptomatic high-grade stenosis. This review focuses on the current data available that will enable the clinician to decide optimal treatment strategies for patients with carotid stenosis.

  3. Increased common carotid artery wall thickness is associated with rapid progression of asymptomatic carotid stenosis.

    Science.gov (United States)

    Diomedi, Marina; Scacciatelli, Daria; Misaggi, Giulia; Balestrini, Simona; Balucani, Clotilde; Sallustio, Fabrizio; Di Legge, Silvia; Stanzione, Paolo; Silvestrini, Mauro

    2014-01-01

    This study aimed to identify clinical and ultrasound imaging predictors of progression of carotid luminal narrowing in subjects with asymptomatic moderate internal carotid artery (ICA) stenosis. A total of 571 subjects with asymptomatic moderate (50-69%) ICA stenoses were enrolled. They underwent ultrasound examination at baseline and after 12 months. Demographics, vascular risk factors, medications, plaque characteristics (surface and echogenicity) and common carotid intima-media thickness (IMT) were collected. At the follow-up examination, any change of ICA stenosis was graded in three categories (i) ≥70% to near occlusion, (ii) near occlusion, and (iii) occlusion. Progression of stenosis was defined as an increase in the stenosis degree by at least one category from baseline to follow-up. At 12 months, progression occurred in 142 subjects (prevalence rate 25%). At the multivariable logistic model, pathological IMT values (considered as binary variable: normal: ≤1 mm vs. pathologic: >1 mm) significantly predicted the risk for plaque progression after adjusting the model for possible confounders (OR 2.28, 95% CI 1.18-4.43, P = .014, multivariable logistic model). Our results confirm the role of carotid wall thickening as a marker of atherosclerosis. Carotid IMT measurement should be considered to implement risk stratification in patients with asymptomatic carotid disease.

  4. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  5. Management of Extracranial Carotid Artery Aneurysm

    NARCIS (Netherlands)

    Welleweerd, J. C.; den Ruijter, H. M.; Nelissen, B. G. L.; Bots, M. L.; Kappelle, L. J.; Rinkel, G. J. E.; Moll, F. L.; de Borst, G. J.

    Introduction: Aneurysms of the extracranial carotid artery (ECAA) are rare. Several treatments have been developed over the last 20 years, yet the preferred method to treat ECAA remains unknown. This paper is a review of all available literature on the risk of complications and long-term outcome

  6. Percutaneous angioplasty of carotid artery stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, G.; Freitag, J.; Koch, R.D.; Wagemann, W.

    1986-03-01

    Percutaneous transluminal angioplasty (PTA) is a well-established method to remedy stenoses and short occlusions in the femoro-popliteal region and has also proved worthwhile in dilating stenoses of pelvic, renal and coronary arteries. Following successful experiments in animals, Mathias et al. employed angioplasty to treat carotid artery stenoses in the same way. To date, successful treatment of carotid artery stenoses has been described only in isolated recent reports. For fear of embolism, angioplasty has not yet become standard practice in this region. Because of the limited number of carotid artery stenoses treated so far, the risk involved cannot be reliably assessed. It is remarkable that no embolism has been reported for the greater number of dilated stenoses of the subclavian artery. Moreover, the report by Mathias et al. indicated that for 350 angioplasties of pelvifemoral arteries 1.1% embolisms occured after artery occlusions only, while no embolism was observed after stenoses. Having gained experience of applying PTA to the treatment of vascular obstructions of extremities, we have adopted this technique in the carotid area as well.

  7. Carotid artery revascularization : Surgical and endovascular developments

    NARCIS (Netherlands)

    Borst, G.J. de

    2007-01-01

    Carotid artery revascularization. Surgical and endovascular developments. Stroke is among the most disabling chronic diseases and the third major cause of death in the Western world. In the Netherlands around 12 per 1000 inhabitants suffers a stroke, and in 2005 over 10.000 people died as a result

  8. Carotid angioplasty and stenting in the elderly

    International Nuclear Information System (INIS)

    Kadkhodayan, Yasha; Cross, DeWitte T.; Moran, Christopher J.; Derdeyn, Colin P.

    2007-01-01

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients ≤79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  9. CAROTID ATHEROSCLEROTIC LESION IN YOUNG PATIENTS

    Directory of Open Access Journals (Sweden)

    N. V. Pizova

    2014-01-01

    Full Text Available Objective: to determine the incidence of atherosclerotic lesions in the carotid and vertebral arteries of young patients from Doppler ultrasound data and to compare the quantitatively assessed traditional risk factors of coronary heart disease (CHD with severe extracranial artery atherosclerotic lesion.Subjects and methods. Doppler ultrasound was carried out evaluating structural changes in the aortic arch branches in 1563 railway transport workers less than 45 years of age. A separate sample consisted of 68 young people with carotid atherosclerotic changes, in whom traditional risk factors for CHD were studied, so were in a control group of individuals without atherosclerotic changes (n = 38.Results. Among the examinees, carotid atherosclerotic lesion was detected in 112 (7.1 % cases, the increase in the rate of atherosclerotic plaques in patients aged 35–45 years being 9.08 %; that in the rate of local intima-media thickness in those aged 31–40 years being 5.1 %. Smoking (particularly that along with hypercholesterolemia and a family history of cardiovascular diseases, obesity (along with low activity, and emotional overstrain were defined as important risk factors in the young patients. Moreover, factor analysis has shown that smoking,hypertension, and early cardiovascular pathology in the next of kin makes the greatest contribution to the development of carotid atherosclerotic lesion.Conclusion. Among the patients less than 45 years of age, carotid and vertebral artery atherosclerotic changes were found in 112 (7.1 % cases, which were more pronounced in male patients. Smoking, particularly along with hypercholesterolemia and genetic predisposition to cardiovascular diseases, was a risk factor that had the highest impact on the degree of atherosclerotic lesion in the aortic arch branches of the young patients.

  10. Uniform nano-ripples on the sidewall of silicon carbide micro-hole fabricated by femtosecond laser irradiation and acid etching

    Energy Technology Data Exchange (ETDEWEB)

    Khuat, Vanthanh [Key Laboratory for Physical Electronics and Devices of the Ministry of Education and Collaborative Innovation Center of Suzhou Nano Science and Technology, School of Electronics and Information Engineering, Xi' an Jiaotong University, No. 28, Xianning West Road, Xi' an 710049 (China); Le Quy Don Technical University, No. 100, Hoang Quoc Viet Street, Hanoi 7EN-248 (Viet Nam); Chen, Tao; Gao, Bo; Si, Jinhai, E-mail: jinhaisi@mail.xjtu.edu.cn; Ma, Yuncan; Hou, Xun [Key Laboratory for Physical Electronics and Devices of the Ministry of Education and Collaborative Innovation Center of Suzhou Nano Science and Technology, School of Electronics and Information Engineering, Xi' an Jiaotong University, No. 28, Xianning West Road, Xi' an 710049 (China)

    2014-06-16

    Uniform nano-ripples were observed on the sidewall of micro-holes in silicon carbide fabricated by 800-nm femtosecond laser and chemical selective etching. The morphology of the ripple was analyzed using scanning electronic microscopy. The formation mechanism of the micro-holes was attributed to the chemical reaction of the laser affected zone with mixed solution of hydrofluoric acid and nitric acid. The formation of nano-ripples on the sidewall of the holes could be attributed to the standing wave generated in z direction due to the interference between the incident wave and the reflected wave.

  11. Bilateral carotid body tumor resection in a female patient

    Directory of Open Access Journals (Sweden)

    Alfred Burgess

    Full Text Available Introduction: Carotid body tumors also called carotid paragangliomas are rare neuroendocrine neoplasms derived from neural crest cells, approximately 3% of all paragangliomas occur in the head and neck area (Xiao and She, 2015; although they represent 65% of the head and neck paragangliomas (Georgiadis et al., 2008. Presentation of case: We present the therapeutic management of a 65-year-old woman with bilateral carotid body tumors. The patient presented to medical clinic for unrelated signs and symptoms of weight loss, dyspepsia, and epigastric pain. Physical examination showed bilateral non-tender neck masses for which imaging studies were ordered resulting in the diagnosis of bilateral carotid tumor. Surgical resection was staged with one week of distance between each tumor resection. Discussion: Carotid Body Tumors can arise from the paraganglia located within the adventitia of the medial aspect of the carotid bifurcation.Resection is the only curative treatment. Carotid body tumors resection represents a special challenge due to potential neurovascular complications. Conclusions: Surgical resection of carotid body tumors represents a special challenge to the surgeon because of the complex anatomical location of the tumor, including close relationship with the cranial nerves, involvement of the carotid vessels and large vascularization of the tumor. With the advance of diagnosis and improvement in surgical techniques as well as the understanding of biological behavior of tumors, surgical treatment has become a safer alternative for treating these tumors. Keywords: Carotid body tumor, Bilateral, Paraganglioma, Resection

  12. Continuous Blood Glucose Monitoring May Detect Carotid Occlusion Intolerance during Carotid Artery Stenting.

    Science.gov (United States)

    Hiramatsu, Ryo; Furuse, Motomasa; Yagi, Ryokichi; Ohmura, Tomohisa; Ohnishi, Hiroyuki; Ikeda, Naokado; Nonoguchi, Naosuke; Kawabata, Shinji; Miyachi, Shigeru; Kuroiwa, Toshihiko

    2018-02-05

    The frequency of the occurrence of adverse events associated with carotid artery stenting (CAS) is usually low, but serious adverse events such as cerebral hyperperfusion syndrome (CHS) may occur. Real-time monitoring is ideal for the early detection of adverse events during the surgical procedure. This study aimed to evaluate continuous blood glucose (BG) monitoring for the detection of adverse events during CAS. Forty patients undergoing scheduled CAS were prospectively enrolled. An artificial pancreas was used for continuous BG monitoring (once per minute), using venous blood extracted at a rate of 2 mL/hr during CAS. The primary endpoint was a correlation between BG change and adverse events. CAS was discontinued in 1 patient, and BG was not measured in 5 patients (12.5%) because of the inability to extract blood. Among 34 evaluable patients, no patient developed CHS, but 3 patients (9%) experienced carotid occlusion intolerance. During CAS, BG was significantly higher in patients with carotid occlusion intolerance (median: 5 mg/dL) than in patients without carotid occlusion intolerance (median: 0 mg/dL) (P = 0.0221). A cutoff BG value ≥4 mg/dL during CAS showed 50% sensitivity and 100% specificity for the detection of carotid occlusion intolerance. There was no significant correlation between BG change and other adverse events. BG elevation may help detect carotid occlusion intolerance although it is still unknown whether BG monitoring can detect CHS. Further studies should validate that a cutoff BG elevation value of ≥4 mg/dL during CAS indicates carotid occlusion intolerance. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Invasive treatment for carotid fibromuscular dysplasia

    Science.gov (United States)

    Maciejewski, Damian R.; Dzierwa, Karolina; Kabłak-Ziembicka, Anna; Michalski, Michał; Wójcik-Pędziwiatr, Magdalena; Brzychczy, Andrzej; Moczulski, Zbigniew; Żmudka, Krzysztof; Pieniążek, Piotr

    2015-01-01

    Introduction Fibromuscular dysplasia (FMD) is an infrequent non-inflamatory disease of unknown etiology that affects mainly medium-size arteries. The prevalence of FMD among patients scheduled for endovascular treatment of carotid artery stenosis is unknown. Aim To evaluate the prevalence and treatment options of carotid FMD in patients scheduled for carotid artery stenting (CAS). Material and methods Between Jan 2001 and Dec 2013, 2012 CAS procedures were performed in 1809 patients (66.1% men; age 65.3 ±8.4 years, 49.2% symptomatic). In case of FMD suspicion in Doppler-duplex ultrasound (DUS), computed tomography angiography was performed for aortic arch and extracranial and intracranial artery imaging. For invasive treatment of FMD carotid stenosis, balloon angioplasty was considered first. If the result of balloon angioplasty was not satisfactory (> 30% residual stenosis, dissection), stent placement was scheduled. All patients underwent follow-up DUS and neurological examination 3, 6 and 12 months after angioplasty, then annually. Results There were 7 (0.4%) (4 symptomatic) cases of FMD. The FMD group was younger (47.9 ±7.5 years vs. 67.2 ±8.9 years, p = 0.0001), with higher prevalence of women (71.4% vs. 32.7%, p = 0.0422), a higher rate of dissected lesions (57.1% vs. 4.6%, p = 0.0002) and less severe stenosis (73.4% vs. 83.9%, p = 0.0070) as compared to the non-FMD group. In the non-FMD group the prevalence of coronary artery disease was higher (65.1% vs. 14.3% in FMD group, p = 0.009). All FMD patients underwent successful carotid artery angioplasty with the use of neuroprotection devices. In 4 cases angioplasty was supported by stent implantation. Conclusions Fibromuscular dysplasia is rare among patients referred for CAS. In case of significant FMD carotid stenosis, it may be treated with balloon angioplasty (stent supported if necessary) with optimal immediate and long-term results. PMID:26161104

  14. How the carotid body works: Different strategies and preparations to solve different problems

    OpenAIRE

    ZAPATA, PATRICIO; LARRAÍN, CAROLINA

    2005-01-01

    This is a review of the different experimental approaches developed to solve the problems in our progress towards a comprehensive understanding of how arterial chemoreceptors operate. An analysis is performed of the bases, advantages and limits of the following preparations: studies of ventilatory reflexes originated from carotid bodies (CBs) in the entire animal; recordings of CB chemosensory discharges in situ; CB preparations perfused in situ; CB explants in oculo; CB explants in ovo; CB p...

  15. Bilateral Internal Carotid Artery Occlusion, External Carotid Artery Stenosis, and Vertebral Artery Kinking: May It Be Asymptomatic?

    Science.gov (United States)

    Fatic, Nikola; Jaffer, Usman; Ivana, Saicic; Gordana, Globarevic-Vukcevic; Markovic, Dragan; Kostic, Dusan; Davidovic, Lazar

    2017-10-01

    The clinical spectrum of internal carotid artery occlusion ranges from being a completely asymptomatic occlusion to a devastating stroke or death. The prevalence of asymptomatic internal carotid artery occlusion is unknown, particularly for bilateral occlusion. The distal branches of the external carotid artery anastomose with distal branches of the internal carotid artery provide important sources of collateral circulation to the brain. Stenosis of the external carotid artery with ipsilateral/bilateral internal occlusion may result in ischemic sequelae. Coiling or kinking of the vertebral artery is a rare morphological entity that is infrequently reported because it remains asymptomatic and has no clinical relevance. Currently, there is little evidence to support management strategies for this disease entity and no official recommendations for asymptomatic bilateral carotid artery occlusion. We present a case of a 62-year-old female with asymptomatic bilateral internal carotid artery occlusion, bilateral external carotid artery stenoses, and bilateral kinking of the vertebral artery at the V2 segment, who has been successfully managed conservatively for over 5 years. An individualized approach to management of patients with bilateral internal carotid artery occlusion, especially in combination with external carotid artery stenosis and elongation malformations of the vertebral artery is key to a successful strategy. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Carotid Velocities Determine Cerebral Blood Flow Deficits in Elderly Men with Carotid Stenosis <50%

    Directory of Open Access Journals (Sweden)

    Arkadiusz Siennicki-Lantz

    2012-01-01

    Full Text Available To examine if mild carotid stenosis correlates with silent vascular brain changes, we studied a prospective population-based cohort “Men born in 1914.” Data from followups at ages 68 and 81, have been used. Carotid ultrasound was performed at age 81, and cerebral blood flow (CBF was measured with SPECT at age 82. Out of 123 stroke-free patients, carotid stenosis <50% was observed in 94% in the right and 89% in the left internal carotid arteries (ICAs. In these subjects, Peak Systolic Velocities in ICA correlated negatively with CBF in a majority of several brain areas, especially in mesial temporal area. Results were limited to normotensive until their seventies, who developed late-onset hypertension with a subsequent blood pressure, pulse pressure, and ankle-brachial index growth. Elderly with asymptomatic carotid stenosis <50% and peak systolic velocities in ICA 0.7–1.3 m/s, should be offered an intensified pharmacotherapy to prevent stroke or silent cerebrovascular events.

  17. Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection.

    Science.gov (United States)

    Harada, Kei; Kakumoto, Kosuke; Oshikata, Shogo; Fukuyama, Kozo

    2018-06-01

    Carotid artery stenting (CAS) with proximal occlusion effectively prevent distal cerebral embolism by flow arrest at internal carotid artery (ICA); however, the method can expose antegrade flow at ICA due to incomplete flow arrest. The aim of this study was to identify predictors of antegrade flow during CAS with proximal protection. We retrospectively analyzed clinical and angiographic data among 143 lesions treated with CAS with proximal protection by occluding the common carotid artery (CCA) and external carotid artery (ECA). Flow arrest or antegrade flow at ICA was confirmed by contrast injection during proximal protection. Antegrade flow at ICA was observed in 12 lesions (8.4%). Compared with lesions in which flow arrest of ICA was achieved, the diameter of the superior thyroid artery (STA) was significantly larger (2.4 ± 0.34 vs. 1.4 ± 0.68 mm, p protection should be combined with proximal protection for the lesions with antegrade flow to prevent distal migration of the carotid debris.

  18. Diagnosis and management of carotid stenosis: a review.

    Science.gov (United States)

    Nussbaum, E S

    2000-01-01

    Since its introduction in the 1950s, carotid endarterectomy has become one of the most frequently performed operations in the United States. The tremendous appeal of a procedure that decreases the risk of stroke, coupled with the large number of individuals in the general population with carotid stenosis, has contributed to its popularity. To provide optimal patient care, the practicing physician must have a firm understanding of the proper evaluation and management of carotid stenosis. Nevertheless, because of the large number of clinical trials performed over the last decade addressing the treatment of stroke and carotid endarterectomy, the care of patients with carotid stenosis remains a frequently misunderstood topic. This review summarizes the current evaluation and treatment options for carotid stenosis and provides a rational management algorithm for this prevalent disease process.

  19. Constructing canine carotid artery stenosis model by endovascular technique

    International Nuclear Information System (INIS)

    Cheng Guangsen; Liu Yizhi

    2005-01-01

    Objective: To establish a carotid artery stenosis model by endovascular technique suitable for neuro-interventional therapy. Methods: Twelve dogs were anesthetized, the unilateral segments of the carotid arteries' tunica media and intima were damaged by a corneous guiding wire of home made. Twenty-four carotid artery stenosis models were thus created. DSA examination was performed on postprocedural weeks 2, 4, 8, 10 to estimate the changes of those stenotic carotid arteries. Results: Twenty-four carotid artery stenosis models were successfully created in twelve dogs. Conclusions: Canine carotid artery stenosis models can be created with the endovascular method having variation of pathologic characters and hemodynamic changes similar to human being. It is useful for further research involving the new technique and new material for interventional treatment. (authors)

  20. The association of carotid cavernous fistula with Graves′ ophthalmopathy

    Directory of Open Access Journals (Sweden)

    Ozlem Celik

    2013-01-01

    Full Text Available Graves′ ophthalmopathy (GO is one of the frequent manifestations of the disorder which is an inflammatory process due to fibroblast infiltration, fibroblast proliferation and accumulation of glycosaminoglycans. Eye irritation, dryness, excessive tearing, visual blurring, diplopia, pain, visual loss, retroorbital discomfort are the symptoms and they can mimic carotid cavernous fistulas. Carotid cavernous fistulas are abnormal communications between the carotid arterial system and the cavernous sinus. The clinical manifestations of GO can mimic the signs of carotid cavernous fistulas. Carotid cavernous fistulas should be considered in the differential diagnosis of the GO patients especially who are not responding to the standard treatment and when there is a unilateral or asymmetric eye involvement. Here we report the second case report with concurrent occurrence of GO and carotid cavernous fistula in the literature.

  1. The association of carotid cavernous fistula with Graves’ ophthalmopathy

    Science.gov (United States)

    Celik, Ozlem; Buyuktas, Deram; Islak, Civan; Sarici, A Murat; Gundogdu, A Sadi

    2013-01-01

    Graves’ ophthalmopathy (GO) is one of the frequent manifestations of the disorder which is an inflammatory process due to fibroblast infiltration, fibroblast proliferation and accumulation of glycosaminoglycans. Eye irritation, dryness, excessive tearing, visual blurring, diplopia, pain, visual loss, retroorbital discomfort are the symptoms and they can mimic carotid cavernous fistulas. Carotid cavernous fistulas are abnormal communications between the carotid arterial system and the cavernous sinus. The clinical manifestations of GO can mimic the signs of carotid cavernous fistulas. Carotid cavernous fistulas should be considered in the differential diagnosis of the GO patients especially who are not responding to the standard treatment and when there is a unilateral or asymmetric eye involvement. Here we report the second case report with concurrent occurrence of GO and carotid cavernous fistula in the literature. PMID:23571267

  2. Advanced Asymptomatic Carotid Disease and Cognitive Impairment: An Understated Link?

    Directory of Open Access Journals (Sweden)

    Irena Martinić-Popović

    2012-01-01

    Full Text Available Advanced carotid disease is known to be associated with symptomatic cerebrovascular diseases, such as stroke or transient ischemic attack (TIA, as well as with poststroke cognitive impairment. However, cognitive decline often occurs in patients with advanced carotid stenosis without clinically evident stroke or TIA, so it is also suspected to be an independent risk factor for dementia. Neurosonological methods enable simple and noninvasive assessment of carotid stenosis in patients at risk of advanced atherosclerosis. Cognitive status in patients diagnosed with advanced carotid stenosis is routinely not taken into consideration, although if cognitive impairment is present, such patients should probably be called symptomatic. In this paper, we discuss results of some most important studies that investigated cognitive status of patients with asymptomatic advanced carotid disease and possible mechanisms involved in the causal relationship between asymptomatic advanced carotid disease and cognitive decline.

  3. Internal Carotid Artery Aneurysm Mimicking Peritonsillar Abscess

    Directory of Open Access Journals (Sweden)

    Jacek Brzost

    2015-01-01

    Full Text Available The extracranial internal carotid artery aneurysm (EICAA is an uncommon arterial lesion. Patients typically present with neurologic symptoms resulting from impaired cerebral perfusion and compression symptoms of cranial nerves. Often EICAA presents as a pulsatile neck mass, which is otherwise asymptomatic. We present a case of an 84-year-old female, who was initially referred to the Emergency Department for Otolaryngology with suspected peritonsillar abscess. The patient had a history of recent upper airway infection and cardiovascular comorbidities, including hypertension and ischaemic stroke complicated by extensive neurologic deficits. Physical examination revealed a compact, nonpulsatile mass in the lateral parapharyngeal space and local erythema of the mucosa. Duplex Doppler Ultrasonography and Computed Tomography revealed an atherosclerotic aneurysm of the right internal carotid artery, measuring 63×55×88 mm, stretching from the skull base to the angle of the mandible.

  4. Idiopathic multiple aneurysm of external carotid artery

    Directory of Open Access Journals (Sweden)

    Saravanan Balachandran

    2014-01-01

    Full Text Available Aneurysms of external carotid artery are rare. Treatments for these are undertaken for the prevention of complications like hemorrhage or rupture, and embolism. We present a 71-year-old male with idiopathic multiple aneurysm for the past 34 years on conservative management and regular follow up for the past 4 years. This case was discussed for the rarity of idiopathic multiple aneurysm of the external carotid artery and the need for individualized treatment protocol to be followed as in this case, only watchful observation considering the age and patient compliance. In this world of evolving surgical techniques and newer treatment modalities, conservative treatment still has a role to play. Primary care physicians at the community level have a major role in following these patients and referring them as and when the need arises.

  5. Asymmetrical distribution of atherosclerosis in the carotid artery: identical patterns across age, race, and gender

    NARCIS (Netherlands)

    Tajik, Parvin; Meijer, Rudy; Duivenvoorden, Raphaël; Peters, Sanne A. E.; Kastelein, John J.; Visseren, Frank J.; Crouse, John R.; Palmer, Mike K.; Raichlen, Joel S.; Grobbee, Diederick E.; Bots, Michiel L.

    2012-01-01

    Background: Small autopsy studies and clinical practice indicated that carotid atherosclerosis develops in an asymmetrical helical pattern coinciding with regions of low shear stress. We investigated the distribution of carotid atherosclerosis as determined by maximum carotid intima-media thickness

  6. File list: Unc.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.CDV.10.AllAg.Carotid_Arteries hg19 Unclassified Cardiovascular Carotid Arteries... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.CDV.10.AllAg.Carotid_Arteries.bed ...

  7. File list: His.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.50.AllAg.Carotid_Arteries hg19 Histone Cardiovascular Carotid Arteries http...://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.50.AllAg.Carotid_Arteries.bed ...

  8. File list: His.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.10.AllAg.Carotid_Arteries hg19 Histone Cardiovascular Carotid Arteries http...://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.10.AllAg.Carotid_Arteries.bed ...

  9. File list: His.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.20.AllAg.Carotid_Arteries hg19 Histone Cardiovascular Carotid Arteries http...://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.20.AllAg.Carotid_Arteries.bed ...

  10. File list: Unc.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.CDV.05.AllAg.Carotid_Arteries hg19 Unclassified Cardiovascular Carotid Arteries... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.CDV.05.AllAg.Carotid_Arteries.bed ...

  11. File list: Unc.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.CDV.20.AllAg.Carotid_Arteries hg19 Unclassified Cardiovascular Carotid Arteries... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.CDV.20.AllAg.Carotid_Arteries.bed ...

  12. File list: His.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available His.CDV.05.AllAg.Carotid_Arteries hg19 Histone Cardiovascular Carotid Arteries http...://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/His.CDV.05.AllAg.Carotid_Arteries.bed ...

  13. File list: Unc.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.CDV.50.AllAg.Carotid_Arteries hg19 Unclassified Cardiovascular Carotid Arteries... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.CDV.50.AllAg.Carotid_Arteries.bed ...

  14. Carotid artery aneurysm resulting in myxedema coma

    Directory of Open Access Journals (Sweden)

    Elizabeth M. Lamos

    2015-06-01

    Full Text Available Intra-sellar aneurysms are a rare, but important consideration when evaluating pituitary masses. Identification of aneurysms is critical to appropriate treatment and avoiding perilous consequences. These vascular aneurysms can result in severe endocrine dysfunction due to mass effect, stripping of the vascular supply to the pituitary, or hemorrhage. Here we describe a novel case of spontaneous myxedema coma and pituitary apoplexy secondary to a large internal carotid artery aneurysm.

  15. Cerebral Ischemia Due to Traumatic Carotid Artery Dissection: Case Report

    OpenAIRE

    Deniz Kamacı Şener; Özlem Taşkapılıoğlu; Nermin Kelebek Girgin; Bahattin Hakyemez; Mustafa Bakar; Yakup Tomak

    2012-01-01

    Blunt injury to the neck region may lead to carotid artery dissection and cerebral ischemia. Blunt injury to carotid artery is not frequent but determination of the presence of trauma in the history of stroke patients will provide early diagnosis and treatment of them. In this article, a case with cerebral ischemia resulting from traumatic carotid artery dissection is presented and clinical findings, diagnostic procedures and choice of treatment are discussed in the light of the literature.

  16. Cerebral Ischemia Due to Traumatic Carotid Artery Dissection: Case Report

    Directory of Open Access Journals (Sweden)

    Deniz Kamacı Şener

    2012-12-01

    Full Text Available Blunt injury to the neck region may lead to carotid artery dissection and cerebral ischemia. Blunt injury to carotid artery is not frequent but determination of the presence of trauma in the history of stroke patients will provide early diagnosis and treatment of them. In this article, a case with cerebral ischemia resulting from traumatic carotid artery dissection is presented and clinical findings, diagnostic procedures and choice of treatment are discussed in the light of the literature.

  17. The selective external carotid arterial embolization treatment of uncontrollable epistaxis

    International Nuclear Information System (INIS)

    Yao Qunli; Liu Yizhi; Ni Caifang

    2004-01-01

    Objective: To evaluate the selective external carotid arterial embolization of uncontrollable epistaxis. Methods: 27 procedures of super-selective external carotid arterial embolization were performed with absorbable gelfoam by using Seldinger's method in 26 cases with uncontrollable epistaxis. Results: 27 procedures of super-selective intra-arterial embolization of uncontrollable epistaxis were all successful without any serious complication. Conclusions: Selective external carotid arterial embolization is safe, effective and successful in the treatment of severe epistaxis. (authors)

  18. Hyperperfusion syndrome after carotid stent angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Reith, W.; Krick, C.; Karp, K.; Zimmer, A.; Struffert, T.; Kuehn, A.L.; Papanagiotou, P. [University of the Saarland, Department for Interventional and Diagnostic Neuroradiology, Homburg (Germany); Roth, C.; Haass, A. [University of the Saarland, Clinic for Neurology, Homburg (Germany)

    2009-03-15

    This study assesses the incidence and causes of hyperperfusion syndrome occurring after carotid artery stenting (CAS). We retrospectively reviewed the clinical database of 417 consecutive patients who were treated with CAS in our department to identify patients who developed hyperperfusion syndrome and/or intracranial hemorrhage. Magnetic resonance imaging (MRI) including fluid-attenuated inversion recovery and diffusion-weighted imaging was performed before and after CAS in 269 cases. A Spearman's rho nonparametric correlation was performed to determine whether there was a correlation between the occurrence/development of hyperperfusion syndrome and the patient's age, degree of stenosis on the stented and contralateral side, risk factors such as diabetes, smoking, hypertension, adiposity, gender and fluoroscopy time, and mean area of postprocedural lesions as well as preexisting lesions. Significance was established at p < 0.05. Of the 417 carotid arteries stented and where MRI was also completed, we found hyperperfusion syndrome in 2.4% (ten cases). Patients who had preexisting brain lesions (previous or acute stroke) were at a higher risk of developing hyperperfusion syndrome (p = 0.022; Spearman's rho test). We could not validate any correlation with the other patient characteristics. Extensive microvascular disease may be a predictor of hyperperfusion syndrome after carotid stent placement. We believe that further studies are warranted to predict more accurately which patients are at greater risk of developing this often fatal complication. (orig.)

  19. Approach To Unstable Plaque In Carotid Disease

    Directory of Open Access Journals (Sweden)

    Mojdeh Ghabaee

    2017-02-01

    Full Text Available Risk of cerebral infarction due to thrombo emboli originating  from carotid artery disease estimated to be near 15%, and this risk  is closely associated with the severity of luminal stenosis. But at the same time characteristics  of the plaque should be taken into account for therapeutic planning when the patient is asymptomatic and the diameter of the stenosis does not reach the threshold of 70%. Search for markers of plaque vulnerability, instability, or thromboembolic potential as complementary to the degree of the luminal stenosis in stroke risk prediction should be considered .These morphologic features of carotid plaques are increasingly believed to be one of those markers that could carry further prognostic information, and early recognition of these plaques features may identify a high-risk subgroup of patients who might particularly benefit from aggressive interventions with aggressive medical treatment. Color and duplex Doppler sonography  evaluates both  morphologic and hemodynamic   abnormalitie of carotid. Echogensity, degree of stenosis and plaque surface features are essential parameters of morphological abnormality.

  20. Artificial Intelligence Estimation of Carotid-Femoral Pulse Wave Velocity using Carotid Waveform.

    Science.gov (United States)

    Tavallali, Peyman; Razavi, Marianne; Pahlevan, Niema M

    2018-01-17

    In this article, we offer an artificial intelligence method to estimate the carotid-femoral Pulse Wave Velocity (PWV) non-invasively from one uncalibrated carotid waveform measured by tonometry and few routine clinical variables. Since the signal processing inputs to this machine learning algorithm are sensor agnostic, the presented method can accompany any medical instrument that provides a calibrated or uncalibrated carotid pressure waveform. Our results show that, for an unseen hold back test set population in the age range of 20 to 69, our model can estimate PWV with a Root-Mean-Square Error (RMSE) of 1.12 m/sec compared to the reference method. The results convey the fact that this model is a reliable surrogate of PWV. Our study also showed that estimated PWV was significantly associated with an increased risk of CVDs.

  1. Management of radiation-induced accelerated carotid atherosclerosis

    International Nuclear Information System (INIS)

    Loftus, C.M.; Biller, J.; Hart, M.N.; Cornell, S.H.; Hiratzka, L.F.

    1987-01-01

    Patients with long survival following cervical irradiation are at risk for accelerated carotid atherosclerosis. The neurologic presentation in these patients mimics naturally occurring atheromatous disease, but patients often present at younger ages and with less concurrent coronary or systemic vascular disease. Hypercholesterolemia also contributes to this accelerated arteriosclerosis. Angiographic findings in this disorder include disproportionate involvement of the distal common carotid artery and unusually long carotid lesions. Pathologic findings include destruction of the internal elastic lamina and replacement of the normal intima and media with fibrous tissue. This article describes two surgical patients with radiation-induced accelerated carotid atherosclerosis who typify the presentation and characteristics of this disease

  2. Subclinical thyroid dysfunction and risk of carotid atherosclerosis.

    Directory of Open Access Journals (Sweden)

    Hosu Kim

    Full Text Available The effect of subclinical thyroid dysfunction on vascular atherosclerosis remains uncertain. The objective of this study was to elucidate the association between sustained subclinical thyroid dysfunction and carotid plaques, which are an early surrogate marker of systemic atherosclerosis.The study included 21,342 adults with consistent thyroid hormonal status on serial thyroid function tests (TFTs and carotid artery duplex ultrasonography at a health screening center between 2007 and 2014. The effect of subclinical thyroid dysfunction on baseline carotid plaques and newly developed carotid plaques during 5-year follow-up was determined by logistic regression analyses and GEE (Generalized Estimating Equations, respectively.Carotid plaques were more common in the subclinical hypothyroidism (55.6% than the euthyroidism (47.8% at baseline. However, in multivariable analysis, thyroid status was not a significant risk for the carotid plaques at baseline. Instead, traditional cardiovascular risk factors, such as age (P <0.001, systolic blood pressure (P = 0.023, fasting blood glucose (P = 0.030, and creatinine (P = 0.012 were associated with baseline carotid plaques in subclinical hypothyroidism. In longitudinal analyses of subjects who were followed up for more than 5 years, there was no significant difference in the cumulative incidence of new carotid plaques according to time between subjects with subclinical hypothyroidism and those with euthyroidism (P = 0.392.Sustained subclinical thyroid dysfunction did not affect the baseline or development of carotid plaques in healthy individuals.

  3. Surgical techniques and curative effect of carotid endarterectomy for carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Min HAN

    2014-02-01

    Full Text Available Objective To investigate the surgical techniques of carotid endarterectomy (CEA for treating carotid artery stenosis, in order to improve the surgical efficacy and reduce intraoperative adverse events and complications after operation. Methods Retrospective analysis was carried out on surgical data of 53 cases who were performed CEA from October 2010 to October 2013 in Department of Neurosurgery in Tianjin Huanhu Hospital. There were 39 males and 14 females, aged from 40 to 78 years old and mean age (60.34 ± 8.92 years old; the course of disease was from 2 d to 4 years. Twenty-six cases were diagnosed as right carotid stenosis, 15 cases left carotid stenosis and 12 cases double-sided carotid stenosis. Among all of those cases, 35 cases were diagnosed as moderate stenosis (30%-69%, 16 cases severe stenosis (70%-99% , and 2 cases complete occlusion. Results Among 53 patients, 50 patients underwent CEA; 2 cases underwent CEA and aneurysm clipping; one case underwent stent removal surgery and CEA because restenosis was found after carotid artery stenting (CAS. Postoperative neck CTA and fMRI showed good morphology of carotid artery, fluent blood flow and improved cerebral perfusion after operation. All of those patients were followed up for 3 to 24 months. One case died of myocardial infarction; 2 cases appeared skin numbness on the operating side of the neck, and the symptom disappeared 3 months later; one case appeared hoarseness after operation; 3 cases experienced mild transient ischemic attack (TIA and the symptom disappeared 2 months later. No case of stroke was found. Conclusions CEA is a safe and effective surgical approach to treat carotid stenosis. Correct and reasonable choices of the surgical indications and skilled surgical technique are the key to ensure the success of operation and to improve efficacy of the therapy. doi:10.3969/j.issn.1672-6731.2014.02.006Video: http://www.cjcnn.org/index.php/cjcnn/pages/view/v14n2a6

  4. The structure of sidewall boundary layers in conned rotating Rayleigh-Bénard convection

    NARCIS (Netherlands)

    Kunnen, R.P.J.; Clercx, H.J.H.; van Heijst, G.J.F.

    2013-01-01

    Turbulent rotating convection is usually studied in a cylindrical geometry, as this is its most convenient experimental realization. In our previous work (Kunnen et al., J. Fluid Mech., vol. 688, 2011, pp. 422–442) we studied turbulent rotating convection in a cylinder with the emphasis on the

  5. Magnetic resonance angiography of the extracranial carotid and vertebral arteries

    International Nuclear Information System (INIS)

    Akimura, Tatsuo; Saito, Kenichi; Nakayama, Hisato; Kashiwagi, Shiro; Kato, Shoichi; Ito, Haruhide.

    1994-01-01

    To evaluate the contribution of magnetic resonance angiography (MRA) in the screening study of the extracranial carotid and vertebral arteries using the conventional head and neck coils, 500 consecutive MRAs of the cervical vessels were performed using 1.5 tesla magnetic resonance unit with circularly polarized head coil. The 5 cm-thick imaging plane was placed in coronal fashion including both carotid and vertebral arteries. The imaging sequence was three-dimensional (3D) fast imaging with steady precession (FISP). In 10 patients with failed head coil examination, 10 patients with possible carotid and vertebral diseases and 10 volunteers, the extracranial carotid and vertebral arteries were examined with the Helmholtz neck coil. Both 3D- and 2D-FISP were performed in each case. The imaging plane was placed in oblique sagittal fashion. In 458 out of 500 cases (91.6%), the extracranial carotid and vertebral arteries were successfully depicted using head coil. In 20 patients with high shoulders, the carotid bifurcations were out of range of the head coil. In these cases, carotid bifurcations and the origins of the carotid and vertebral arteries were successfully revealed using a neck coil. To evaluate the stenotic lesions and tortuous vessels, 2D-FISP sequence seemed to be more suitable than 3D-FISP. Compared with conventional angiography, MRA caused overestimation of the degree of stenotic lesions. For screening examination of the extracranial carotid and vertebral arteries, most cases can be evaluated only with the conventional head coil. If depiction of the carotid bifurcation fails and the examination of carotids or vertebrals down to the aortic arch is needed, neck coil examination is required. (author)

  6. Treatment of carotid siphon aneurysms by use of the Willis stent graft: an angiographic and histopathological study

    International Nuclear Information System (INIS)

    Zhu, Yue-Qi; Li, Ming-Hua; Xie, Jian; Tan, Hua-Qiao; Wang, Jian-Bo; Cheng, Ying-Sheng

    2010-01-01

    We designed a carotid siphon (CS) aneurysm model in dogs to test a new stent graft (the Willis covered stent) and compared tissue reaction over 12-month follow-up versus a comparison group with stents implanted in straight vessels. Twenty-four saccular sidewall aneurysms (group A) and 12 CS aneurysms (group B) were created surgically. A Willis stent graft was implanted in each aneurysm. Angiography was performed immediately and at 1-, 3-, 6- and 12-month post-implantation to investigate aneurysm isolation, endoleak, stent angulation, parent artery (PA) patency and restenosis. Light and scanning electron microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress. Immediate angiography demonstrated mild endoleak in two aneurysms and three stent angulations in group B. Follow-up at 12 months revealed resolved endoleaks, occlusion in one PA and mild stenosis in three in group B. In group A, occlusion occurred in one PA and mild stenosis in two. Light microscopy revealed new intima, and all aneurysm sacs were filled with thrombi. In group B, endothelial progress was complete at 12 months, and closely correlated with haemodynamic changes. Application of a Willis stent graft is a feasible method of treating CS aneurysms, and it exhibits a prolonged endothelial progress compared with that in straight vessels. (orig.)

  7. Comparisons of carotid artery stenting and carotid endoarterectomy in terms of diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Mitsuoka, Hiroshi; Shintani, Tsunehiro; Masuda, Mikio; Higashi, Shigeki

    2009-01-01

    The objective of this study was to compare two methods of treatment for carotid arterial stenosis, carotid endarterectomy (CEA) and carotid artery stenting (CAS), by means of diffusion-weighted MR imaging (DWI). Nineteen treatments in 18 cases during the 2007 academic year were included in this study. CAS was performed for 9 cases with 10 lesions (10 procedures), while 9 cases with 9 lesions (9 procedures) were treated by CEA. Patients were examined by a neurologist before and after the procedure, and had pre- and post-procedural DWI. No strokes or transient ischemic attacks (TIAs) were observed in these cases. New DWI lesions were found in 7 out of the 10 procedures of CAS imaged 24 hours postprocedure, (average: 2.0 lesions). No new lesions were detected on DWI of CEA cases (χ 2 =8.33, p=0.0039). Certain high-risk subsets may respond well to CAS with a very low incidence of clinically-evident neurologic events, but with significantly higher incidence of periprocedural micro-brain embolism. Currently, CEA should be the first choice of treatment for atherosclerotic carotid artery stenosis. (author)

  8. Carotid Ultrasound for Assessment of Nonobstructive Carotid Atherosclerosis in Young Adults with Cryptogenic Stroke.

    Science.gov (United States)

    Buon, Raphael; Guidolin, Brigitte; Jaffre, Aude; Lafuma, Marie; Barbieux, Marianne; Nasr, Nathalie; Larrue, Vincent

    2018-05-01

    The role of nonobstructive (young adults with ischemic stroke is not well understood. In the present study, we investigated the prevalence and the ultrasonic characteristics of NOCA in a consecutive series of young adults with cryptogenic stroke (CS). Patients aged 18-54, consecutively treated in a tertiary hospital for first-ever CS (defined as an ischemic stroke without ASCOD (A: atherosclerosis; S: small-vessel disease; C: cardiac pathology; O: other causes) grade 1 potential cause) in the carotid artery territory, were prospectively enrolled. NOCA was assessed using carotid duplex ultrasonography. Of 148 patients with first-ever ischemic stroke, 70 had CS, including 44 patients with carotid CS. NOCA was found in 22 of 44 (50%) patients. All but 1 plaque were echolucent. NOCA was bilateral in 15 patients and unilateral in 7 patients. All unilateral plaques were on the symptomatic side (P = .02). Plaque thickness, plaque length, and plaque volume were greater on the symptomatic side than on the asymptomatic side (P = .001, P young adults with CS. Measurement of the plaque burden with carotid duplex may help to identify symptomatic NOCA. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  9. Safety of Carotid Artery Stenting in Elderly Patients with Severe Carotid Artery Stenosis

    International Nuclear Information System (INIS)

    Choi, Seul Kee; Kim, Seul Kee; Jeong, Min Young; Yoon, Woong

    2012-01-01

    To determine the safety of carotid artery stenting (CAS) using an emboli-protection device in elderly patients with severe carotid artery stenosis. Ninety consecutive patients who were at high risk for carotid endarterectomy underwent protected CAS using an emboli-protection device. Patients were divided into two groups by age: < 70 and ≥ 70. The primary outcome measure was the combined incidence of stroke, myocardial infarction (MI), and death within 30 days of CAS. The secondary outcome measures were technical success and hyperperfusion syndrome. Associations between age and the clinical outcomes were investigated. Overall, 30-day stroke, MI, and death rates were 6.7%. There was no significant difference in the primary outcome between the older age group (n = 56) and younger age group (n = 34) (8.9% and 2.9%, respectively; HR for age ≥ 70, 1.141; 95% CI, 0.875 to 1.488, p = 0.331). A logistic regression showed there was no independent variable associated with primary outcome. Technical success was achieved in all patients and there was no significant difference in the incidence of hyperperfusion syndrome between the two age groups. The results of this study suggest that protected CAS seems to be safe in elderly patients with severe carotid artery stenosis.

  10. Carotid bifurcation calcium and correlation with percent stenosis of the internal carotid artery on CT angiography

    International Nuclear Information System (INIS)

    McKinney, Alexander M.; Casey, Sean O.; Teksam, Mehmet; Truwit, Charles L.; Kieffer, Stephen; Lucato, Leandro T.; Smith, Maurice

    2005-01-01

    The aim of this paper was to determine the correlation between calcium burden (expressed as a volume) and extent of stenosis of the origin of the internal carotid artery (ICA) by CT angiography (CTA). Previous studies have shown that calcification in the coronary arteries correlates with significant vessel stenosis, and severe calcification (measured by CT) in the carotid siphon correlates with significant (greater than 50% stenosis) as determined angiographically. Sixty-one patients (age range 50-85 years) underwent CT of the neck with intravenous administration of iodinated contrast for a variety of conditions. Images were obtained with a helical multidetector array CT scanner and reviewed on a three-dimensional workstation. A single observer manipulated window and level to segment calcified plaque from vascular enhancement in order to quantify vascular calcium volume (cc) in the region of the bifurcation of the common carotid artery/ICA origin, and to measure the extent of ICA stenosis near the origin. A total of 117 common carotid artery bifurcations were reviewed. A ''significant'' stenosis was defined arbitrarily as >40% (to detect lesions before they become hemodynamically significant) of luminal diameter on CTA using NASCET-like criteria. All ''significant'' stenoses (21 out of 117 carotid bifurcations) had measurable calcium. We found a relatively strong correlation between percent stenosis and the calcium volume (Pearson's r= 0.65, P<0.0001). We also found that there was an even stronger correlation between the square root of the calcium volume and the percent stenosis as measured by CTA (r= 0.77, P<0.0001). Calcium volumes of 0.01, 0.03, 0.06, 0.09 and 0.12 cc were used as thresholds to evaluate for a ''significant'' stenosis. A receiver operating characteristic (ROC) curve demonstrated that thresholds of 0.06 cc (sensitivity 88%, specificity 87%) and 0.03 cc (sensitivity 94%, specificity 76%) generated the best combinations of sensitivity and

  11. Spontaneous carotid artery dissection causing a juvenile cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Trattnig, S.; Huebsch, P.; Schindler, E.

    1988-11-01

    The case of a 19-year-old patient is presented who was admitted with aphasia and hemiparesis due to basal ganglia infarction as a result of spontaneous dissection of the internal carotid artery. The difficulties in diagnosing this disease with CT and MRI in the acute stage are demonstrated. Angiography is still imperative in order to ascertain that a carotid dissection has occurred.

  12. Cerebral monitoring during carotid endarterectomy – a comparison ...

    African Journals Online (AJOL)

    All patients had general anaesthesia and were operated on by the same vascular surgeon (JvM). All patients were evaluated preoperatively by an experienced sonographer. Cerebral monitoring during carotid endarterectomy – a comparison between electroencephalography, transcranial cerebral oximetry and carotid ...

  13. Thrombosis of internal carotid artery following blunt neck injuries

    International Nuclear Information System (INIS)

    Houdek, M.; Klaus, E.

    1986-01-01

    Complicated problems of nonpenetrating injuries of the internal carotid artery, their pathophysiological mechanisms, clinical picture, diagnosis and therapy are analyzed. The possible surgical management is considered. Attention was paid to angiographic diagnosis of traumatic and spontaneous lesions of internal carotid arteries. (author). 87 refs

  14. Re-establishment of cerebral metabolism after carotid endarterectomy

    NARCIS (Netherlands)

    Balm, R.; van der Grond, J.; Mali, W. P.; Eikelboom, B. C.

    1995-01-01

    OBJECTIVES: The purpose of this study was to evaluate the metabolic changes that occur in the human brain in patients with a symptomatic carotid artery stenosis. MATERIALS AND METHODS: N-acetyl-aspartate (NAA), choline, creatine and lactate were measured both before, and 4 days after, carotid

  15. Carotid artery disease and low cerebral perfusion pressure

    DEFF Research Database (Denmark)

    Schroeder, T; Utzon, N P; Aabech, J

    1990-01-01

    Direct internal carotid artery blood pressure measurements in patients undergoing carotid endarterectomy identified 49 patients, among 239 consecutive cases (21%), who had a reduction in perfusion pressure of 20% or more. The clinical history, objective findings and angiographic data were compared...

  16. Indirect carotid- cavernous fistula — embolisation using the superior ...

    African Journals Online (AJOL)

    Kurt

    MD, FRCS (C). Division of Neurosurgery. Royal University Hospital. University of Saskatchewan. Saskatoon. Canada. Fig .1a. Left common carotid angiogram, AP view, showing the carotid-cavernous fistula. Note opaci- fication of the left cavernous sinus (arrow) and fill- ing of the right cavernous sinus (double arrows).

  17. Carotid Artery Stenting and Endarterectomy: a clinical evaluation

    NARCIS (Netherlands)

    J.M. Hendriks (Joke)

    2011-01-01

    textabstractStroke is a major cause of mortality and morbidity in the western world. Atherosclerotic disease of the carotid arteries is in approximately 25% of the cases responsible for the cerebral infarction.1 Since NASCET and ECST, carotid endarterectomy (CEA) is considered the standard treatment

  18. Carotid Body Tumor Presenting as Parotid Swelling Misdiagnosed ...

    African Journals Online (AJOL)

    Carotid body tumor (CBT) also known as chemodectoma is a rare tumor of neuroendocrine tissue of carotid body and is the most commonly seen jugular paraganglioma. In most cases, it is benign but it can be malignant. Extra adrenal paraganglioma is rare. We present such a rare case where unusual presentation of ...

  19. Redeposition of etch products on sidewalls during SiO2 etching in a fluorocarbon plasma. I. Effect of particle emission from the bottom surface in a CF4 plasma

    International Nuclear Information System (INIS)

    Min, Jae-Ho; Hwang, Sung-Wook; Lee, Gyeo-Re; Moon, Sang Heup

    2002-01-01

    The effect of etch-product redeposition on sidewall properties during the etching of step-shaped SiO 2 patterns in a CF 4 plasma was examined using a Faraday cage located in a transformer coupled plasma etcher. Sidewall properties were observed for two cases: with and without particles emitted from the bottom surface in normal contact with the sidewall. Particles sputtered from the bottom surface were redeposited on the sidewall, which contributes to the formation of a passivation layer on the surface of the latter. The passivation layer consisted of silicon oxide, Si x O y , and fluorocarbon, C x F y , the latter comprising the major species. Ar plasma experiments confirmed that C x F y or a fluorocarbon polymer must be present on the sidewall in order for the Si x O y species to be deposited on the surface. The redeposited particles, which were largely F-deficient fluorocarbon species, as evidenced by x-ray photoelectron spectroscopy analyses, functioned as precursors for fluorocarbon polymerization, resulting in a rough sidewall surface. The chemical etch rates of SiO 2 were retarded by the redeposition of particles, which eventually formed a thick layer, eventually covering the bulk SiO 2 . Auger electron spectroscopy analyses of the sidewall surface affected by the emission from the bottom suggest that the surface consists of three distinct layers: a surface-carbon layer, a redeposition-etch combined layer, and bulk SiO 2

  20. Noninvasive characterization of carotid plaque strain.

    Science.gov (United States)

    Khan, Amir A; Sikdar, Siddhartha; Hatsukami, Thomas; Cebral, Juan; Jones, Michael; Huston, John; Howard, George; Lal, Brajesh K

    2017-06-01

    Current risk stratification of internal carotid artery plaques based on diameter-reducing percentage stenosis may be unreliable because ischemic stroke results from plaque disruption with atheroembolization. Biomechanical forces acting on the plaque may render it vulnerable to rupture. The feasibility of ultrasound-based quantification of plaque displacement and strain induced by hemodynamic forces and their relationship to high-risk plaques have not been determined. We studied the feasibility and reliability of carotid plaque strain measurement from clinical B-mode ultrasound images and the relationship of strain to high-risk plaque morphology. We analyzed carotid ultrasound B-mode cine loops obtained in patients with asymptomatic ≥50% stenosis during routine clinical scanning. Optical flow methods were used to quantify plaque motion and shear strain during the cardiac cycle. The magnitude (maximum absolute shear strain rate [MASSR]) and variability (entropy of shear strain rate [ESSR] and variance of shear strain rate [VSSR]) of strain were combined into a composite shear strain index (SSI), which was assessed for interscan repeatability and correlated with plaque echolucency. Nineteen patients (mean age, 70 years) constituting 36 plaques underwent imaging; 37% of patients (n = 7) showed high strain (SSI ≥0.5; MASSR, 2.2; ESSR, 39.7; VSSR, 0.03) in their plaques; the remaining clustered into a low-strain group (SSI routine B-mode imaging using clinical ultrasound machines. High plaque strain correlates with known high-risk echolucent morphology. Strain measurement can complement identification of patients at high risk for plaque disruption and stroke. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. Extramedullary plasmacytoma in the carotid space: Expanding the differential diagnosis

    International Nuclear Information System (INIS)

    Deshpande, Sneha Satish; Kane, Shubhada; Arya, Supreeta

    2014-01-01

    Plasma cell neoplasms have been classified into various types, with a range of clinical and radiological presentations. Extramedullary plasmacytoma (EMP) is a subset of plasma cell neoplasms which presents as an isolated non-osseous soft tissue mass. Though carotid space neoplasms are commonly encountered, EMP in the carotid space is rare and seldom considered in the initial differential diagnosis of a carotid space mass. These tumors can be treated by surgery or radiotherapy. On the other hand, the commonly encountered tumors in the carotid space are treated surgically. Also, it is mandatory to exclude multiple myeloma in the patients presenting with EMP. Hence, accurate and early diagnosis has therapeutic and prognostic implications. We report a rare case of EMP of the carotid space, describing the imaging features and the differential diagnoses with clues pointing to this rare entity

  2. Supraorbital cutaneous blood flow rate during carotid endarterectomy

    DEFF Research Database (Denmark)

    Hove, Jens D; Rosenberg, Iben; Sejrsen, Per

    2006-01-01

    : The supraorbital cutaneous blood flow rate was measured by the application of heat to the skin and following the subsequent dissipation of the heat in seven patients undergoing carotid endarterectomy. At the same time, the oxygenation in the right and left frontal region was monitored by near-infrared spectroscopy......BACKGROUND: The supraorbital skin region is supplied by the supraorbital artery, which is a branch of the internal carotid artery. The supraorbital cutaneous blood flow rate may therefore be influenced by changes in the internal carotid artery flow during carotid endarterectomy. METHODS...... (NIRS). RESULTS: During cross-clamping of the carotid artery, the ipsilateral NIRS-determined frontal oxygenation tended to decrease [67 +/- 13% to 61 +/- 11% (P = 0.06); contralateral 68 +/- 11% to 66 +/- 8%] as did the supraorbital cutaneous blood flow rate from 56 +/- 23 to 44 +/- 7 ml 100 g(-1) min...

  3. Congenital Absence of the Internal Carotid Artery

    International Nuclear Information System (INIS)

    Florio, Francesco; Balzano, Silverio; Nardella, Michele; Strizzi, Vincenzo; Cammisa, Mario; Bozzini, Vincenzo; Catapano, Giuseppe; D'Angelo, Vincenzo

    1999-01-01

    We report three cases of congenital absence of an internal carotid artery (ICA), diagnosed incidentally by digital subtraction angiography. The analysis of the cases is based on the classification of segmental ICA agenesis proposed by Lasjaunias and Berenstein. Usually the patients with this rare vascular anomaly are asymptomatic; some may have symptoms related to cerebrovascular insufficiency, compression by enlarged intracranial collateral vessels, or complications associated with cerebral aneurysms. Diagnosis of congenital absence of ICA is made by skull base computed tomography (CT) scan, CT and magnetic resonance angiography, and conventional or digital subtraction angiography

  4. Causal feedforward control of a stochastically excited fuselage structure with active sidewall panel.

    Science.gov (United States)

    Misol, Malte; Haase, Thomas; Monner, Hans Peter; Sinapius, Michael

    2014-10-01

    This paper provides experimental results of an aircraft-relevant double panel structure mounted in a sound transmission loss facility. The primary structure of the double panel system is excited either by a stochastic point force or by a diffuse sound field synthesized in the reverberation room of the transmission loss facility. The secondary structure, which is connected to the frames of the primary structure, is augmented by actuators and sensors implementing an active feedforward control system. Special emphasis is placed on the causality of the active feedforward control system and its implications on the disturbance rejection at the error sensors. The coherence of the sensor signals is analyzed for the two different disturbance excitations. Experimental results are presented regarding the causality, coherence, and disturbance rejection of the active feedforward control system. Furthermore, the sound transmission loss of the double panel system is evaluated for different configurations of the active system. A principal result of this work is the evidence that it is possible to strongly influence the transmission of stochastic disturbance sources through double panel configurations by means of an active feedforward control system.

  5. Experiences with carotid endarterectomy at Sree Chitra Tirunal Institute

    Directory of Open Access Journals (Sweden)

    Unnikrishnan Madathipat

    2008-01-01

    Full Text Available Background: Atherosclerotic carotid artery disease poses a grave threat to cerebral circulation, leading to a stroke with its devastating sequelae, if left untreated. Carotid endarterectomy has a proven track record with compelling evidence in stroke prevention. Objectives: aTo confirm that carotid endarterectomy (CEA is safe and effective in preventing stroke at both short and long term. b to demonstrate long term patency of internal carotid artery when arteriotomy repair is performed using autologous saphenous vein patch. Materials and Methods: During ten years, from September 1997 to February 2008, thirty nine patients who underwent consecutive carotid endarterectomy at our institute, form the basis of this report. Their age ranged from thirty to seventy eight years, with a mean age of 56. There were four women in this cohort. Thirty seven patients were symptomatic with> 70% stenosis and two were asymptomatic with> 80% stenosis, incidentally detected. Imaging included Duplex scan and MRA for carotid territory and brain, and non-invasive cardiac assessment. Co-morbidities included smoking, hypertension, diabetes, and coronary artery disease. Carotid Endarterectomy was performed under general anaesthesia, using carotid shunt and vein patch arteriotomy repair. Results: All the patients made satisfactory recovery, without major adverse cerebral events in this series. Morbidities included Transient Ischemic Attack (TIA in two, needing only medications in one, and carotid stenting in the other. Minor morbidities included neck hematoma in two and transient hypoglossal paresis in three patients. Yearly follow-up included duplex scan assessment for all the patients. Two patients died of contralateral stroke, two of myocardial events and two were lost to follow up. Thirty three patients are well and free of the disease during the follow up of three to 120 months. Conclusion: Carotid endarterectomy provided near total freedom from adverse cerebral

  6. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  7. Hemodynamic study on flow patterns in the carotid bifurcation before and after carotid endarterectomy using cine magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamane, Kanji; Shima, Takeshi; Okada, Yoshikazu; Nishida, Masahiro; Okita, Shinji; Hanaguri, Katsuro [Chugoku Rousai Hospital, Kure, Hiroshima (Japan)

    1993-11-01

    Blood flow in the cervical carotid bifurcation was investigated by cine magnetic resonance imaging. In patients with stenosis, a low-intensity stream was demonstrated from the beginning of the carotid bulb, which was more distinct in the systolic phase. In patients with stenotic carotid bifurcations,the low-intensity flow was also present but was more prominent than in the non-stenotic bifurcation. This low-intensity stream may be due to the change from steady to turbulent flow due to the geometric characteristics of the carotid bifurcation or atheromatous plaque, similar to the flow separation phenomenon in fluid dynamics because of the coincidence of location and flow pattern. After carotid endarterectomy, turbulent flow was seen at the proximal and distal ends of the endarterectomy. Close follow-up and administration of antiplatelet agents are necessary to prevent restenosis due to mural thrombosis induced by such turbulent flow. (author).

  8. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  9. Numerical investigation of double diffusive buoyancy forces induced natural convection in a cavity partially heated and cooled from sidewalls

    Directory of Open Access Journals (Sweden)

    Rasoul Nikbakhti

    2016-03-01

    Full Text Available This paper deals with a numerical investigation of double-diffusive natural convective heat and mass transfer in a cavity filled with Newtonian fluid. The active parts of two vertical walls of the cavity are maintained at fixed but different temperatures and concentrations, while the other two walls, as well as inactive areas of the sidewalls, are considered to be adiabatic and impermeable to mass transfer. The length of the thermally active part equals half of the height. The non-dimensional forms of governing transport equations that describe double-diffusive natural convection for two-dimensional incompressible flow are functions of temperature or energy, concentration, vorticity, and stream-function. The coupled differential equations are discretized via FDM (Finite Difference Method. The Successive-Over-Relaxation (SOR method is used in the solution of the stream function equation. The analysis has been done for an enclosure with different aspect ratios ranging from 0.5 to 11 for three different combinations of partially active sections. The results are presented graphically in terms of streamlines, isotherms and isoconcentrations. In addition, the heat and mass transfer rate in the cavity is measured in terms of the average Nusselt and Sherwood numbers for various parameters including thermal Grashof number, Lewis number, buoyancy ratio and aspect ratio. It is revealed that the placement order of partially thermally active walls and the buoyancy ratio influence significantly the flow pattern and the corresponding heat and mass transfer performance in the cavity.

  10. Fundamental characterization of the effect of nitride sidewall spacer process on boron dose loss in ultra-shallow junction formation

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, P. [Silicon Technology Development, Texas Instruments, Dallas, TX 75243 (United States) and Microelectronics Research Center, University of Texas, Austin, TX 78758 (United States)]. E-mail: puneet.kohli@sematech.org; Chakravarthi, S. [Silicon Technology Development, Texas Instruments, Dallas, TX 75243 (United States); Jain, Amitabh [Silicon Technology Development, Texas Instruments, Dallas, TX 75243 (United States); Bu, H. [Silicon Technology Development, Texas Instruments, Dallas, TX 75243 (United States); Mehrotra, M. [Silicon Technology Development, Texas Instruments, Dallas, TX 75243 (United States); Dunham, S.T. [Department of Electrical Engineering, University of Washington, Seattle, WA 98195 (United States); Banerjee, S.K. [Microelectronics Research Center, University of Texas, Austin, TX 78758 (United States)

    2004-12-15

    A nitride spacer with an underlying deposited tetraethoxysilane (TEOS) oxide that behaves as a convenient etch stop layer is a popular choice for sidewall spacer in modern complementary metal oxide semiconductor (CMOS) process flows. In this work, we have investigated the effect of the silicon nitride spacer process chemistry on the boron profile in silicon and the related dose loss of B from Si into silicon dioxide. This is reflected as a dramatic change in the junction depth, junction abruptness and junction peak concentration for the different nitride chemistries. We conclude that the silicon nitride influences the concentration of hydrogen in the silicon dioxide and different nitride chemistries result in different concentrations of hydrogen in the silicon dioxide during the final source/drain anneal. The presence of H enhances the diffusivity of B in the silicon dioxide and thereby results in a significant dose loss from the Si into the silicon dioxide. In this work, we show that this dose loss can be minimized and the junction profile engineered by choosing a desirable nitride chemistry.

  11. Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

    Science.gov (United States)

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2014-01-01

    We investigated the flow modifications induced by a large panel of commercial-off-the-shelf (COTS) intracranial stents in an idealized sidewall intracranial aneurysm (IA). Flow velocities in IA silicone model were assessed with and without stent implantation using particle imaging velocimetry (PIV). The use of the recently developed multi-time-lag method has allowed for uniform and precise measurements of both high and low velocities at IA neck and dome, respectively. Flow modification analysis of both regular (RSs) and flow diverter stents (FDSs) was subsequently correlated with relevant geometrical stent parameters. Flow reduction was found to be highly sensitive to stent porosity variations for regular stents RSs and moderately sensitive for FDSs. Consequently, two distinct IA flow change trends, with velocity reductions up to 50% and 90%, were identified for high-porosity RS and low-porosity FDS, respectively. The intermediate porosity (88%) regular braided stent provided the limit at which the transition in flow change trend occurred with a flow reduction of 84%. This transition occurred with decreasing stent porosity, as the driving force in IA neck changed from shear stress to differential pressure. Therefore, these results suggest that stents with intermediate porosities could possibly provide similar flow change patterns to FDS, favourable to curative thrombogenesis in IAs.

  12. Clinical utility of carotid duplex ultrasound prior to cardiac surgery.

    Science.gov (United States)

    Lin, Judith C; Kabbani, Loay S; Peterson, Edward L; Masabni, Khalil; Morgan, Jeffrey A; Brooks, Sara; Wertella, Kathleen P; Paone, Gaetano

    2016-03-01

    Clinical utility and cost-effectiveness of carotid duplex examination prior to cardiac surgery have been questioned by the multidisciplinary committee creating the 2012 Appropriate Use Criteria for Peripheral Vascular Laboratory Testing. We report the clinical outcomes and postoperative neurologic symptoms in patients who underwent carotid duplex ultrasound prior to open heart surgery at a tertiary institution. Using the combined databases from our clinical vascular laboratory and the Society of Thoracic Surgery, a retrospective analysis of all patients who underwent carotid duplex ultrasound within 13 months prior to open heart surgery from March 2005 to March 2013 was performed. The outcomes between those who underwent carotid duplex scanning (group A) and those who did not (group B) were compared. Among 3233 patients in the cohort who underwent cardiac surgery, 515 (15.9%) patients underwent a carotid duplex ultrasound preoperatively, and 2718 patients did not (84.1%). Among the patients who underwent carotid screening vs no screening, there was no statistically significant difference in the risk factors of cerebrovascular disease (10.9% vs 12.7%; P = .26), prior stroke (8.2% vs 7.2%; P = .41), and prior transient ischemic attack (2.9% vs 3.3%; P = .24). For those undergoing isolated coronary artery bypass grafting (CABG), 306 (17.8%) of 1723 patients underwent preoperative carotid duplex ultrasound. Among patients who had carotid screening prior to CABG, the incidence of carotid disease was low: 249 (81.4%) had minimal or mild stenosis (duplex scanning and those who did not. Primary outcomes of patients who underwent open heart surgery also showed no difference in the perioperative mortality (5.1% vs 6.9%; P = .14) and stroke (2.6% vs 2.4%; P = .85) between patients undergoing preoperative duplex scanning and those who did not. Operative intervention of severe carotid stenosis prior to isolated CABG occurred in 2 of the 17 patients (11.8%) identified who

  13. Cognitive changes after carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Supprian, T.; Falkai, P.; Reith, W. [University of the Saarland, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2006-05-15

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9{+-}1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  14. Cognitive changes after carotid artery stenting

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M.; Supprian, T.; Falkai, P.; Reith, W.

    2006-01-01

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9±1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  15. Indium-111 platelet scintigraphy in carotid disease

    International Nuclear Information System (INIS)

    Branchereau, A.; Bernard, P.J.; Ciosi, G.; Bazan, M.; de Laforte, C.; Elias, A.; Bouvier, J.L.

    1988-01-01

    Forty-five patients (35 men, 10 women) undergoing carotid surgery had Indium-111 platelet scintigraphy as part of their preoperative work-up. Imaging was performed within three hours after injection of the Indium-111. A second series of views was obtained 24 hours later and repeated at 24 hour intervals for two days. Of 54 scintigrams, 22 were positive and 32 negative. Positive results were defined as a twofold or more increase in local activity on a visualized carotid after 24 hours. The sensitivity of the method was 41%, intraoperatively, and the specificity, 100%. The low sensitivity places this method behind sonography and duplex-scanning for screening patients for surgery. We believe that indications for platelet scintigraphy are limited to: 1. Repeated transient ischemic attacks in the same territory with minimal lesions on arteriography and non-homogeneous plaque on duplex scan; 2. Symptomatic patients being treated medically as a possible argument for surgery; 3. Determining therapeutic policy for patients having experienced a transient ischemic attack with a coexisting intracardiac thrombus

  16. Clinical study of internal carotid artery occlusion

    International Nuclear Information System (INIS)

    Okada, Kyoko

    1989-01-01

    Fourteen patients with internal carotid artery (ICA) occlusion identified by cerebral angiography were studied for clinical features, computed tomographic findings, collateral circulation and risk factors. Eleven patients were males, and at age distribution it occurred more frequently in patients over 50 years to 60 years of age rather than other ages. As for the risk factors of cerebral infarction, smoking was more frequent in patients with thrombosis, and heart disease was more common in those with embolism. Stroke occurred progressively in patients with thrombosis whereas it occurred suddenly in those with embolism. The consciousness was more severely disturbed in patients with embolism than in those with thrombosis. On neuro-radiological findings, in the patients with thrombosis, the infarcted area on CT were small and emerged as deep or watershed types, and on the angiograms, occlusion at carotid bifurcation were found more frequently and the collateral circulation were well developed. In those with embolism, the infarcted areas were large and emerged as cortical types, and on the angiograms, occlusions were observed more frequently in the intracranial portion and collateral circulation were poorly developed. In many patients with thrombosis, platelet aggregation, hematocrit and blood viscosity increased, but in those with embolism did not. (author)

  17. Low-resistivity C54-TiSi2 as a sidewall-confinement nanoscale electrode for three-dimensional vertical resistive memory

    KAUST Repository

    Duran Retamal, Jose Ramon; Kang, Chen-Fang; Yang, Po-Kang; Lee, Chuan-Pei; Lien, Der-Hsien; Ho, Chih-Hsiang; He, Jr-Hau

    2014-01-01

    A three-dimensional (3D) double-layer HfO2-based vertical-resistive random access memory (VRRAM) with low-resistivity C54-TiSi2 as horizontal electrodes is demonstrated using complementary metal-oxide semiconductor processing. The electrical measurements show bipolar resistive switching by using C54-TiSi2 as electrodes for resistive switching (RS) applications. The statistical analysis exhibits cycle-to-cycle and cell-to-cell stable non-volatile properties with robust endurance (100 cycles) and long term data retention (104s), suggesting that the ultrathin sidewall of C54-TiSi2 nanoscale electrodes serve to confine and stabilize the random nature of the conducting nanofilaments. The superior RS characteristics demonstrated here highlight the applicability of C54-TiSi2 sidewall-confinement nanoscale electrodes to VRRAM.

  18. Low-resistivity C54-TiSi2 as a sidewall-confinement nanoscale electrode for three-dimensional vertical resistive memory

    KAUST Repository

    Duran Retamal, Jose Ramon

    2014-11-03

    A three-dimensional (3D) double-layer HfO2-based vertical-resistive random access memory (VRRAM) with low-resistivity C54-TiSi2 as horizontal electrodes is demonstrated using complementary metal-oxide semiconductor processing. The electrical measurements show bipolar resistive switching by using C54-TiSi2 as electrodes for resistive switching (RS) applications. The statistical analysis exhibits cycle-to-cycle and cell-to-cell stable non-volatile properties with robust endurance (100 cycles) and long term data retention (104s), suggesting that the ultrathin sidewall of C54-TiSi2 nanoscale electrodes serve to confine and stabilize the random nature of the conducting nanofilaments. The superior RS characteristics demonstrated here highlight the applicability of C54-TiSi2 sidewall-confinement nanoscale electrodes to VRRAM.

  19. Enhanced carotid body chemosensory activity and the cardiovascular alterations induced by intermittent hypoxia

    Directory of Open Access Journals (Sweden)

    Rodrigo eIturriaga

    2014-12-01

    Full Text Available The carotid body (CB plays a main role in the maintenance of the oxygen homeostasis. The hypoxic stimulation of the CB increases the chemosensory discharge, which in turn elicits reflex sympathetic, cardiovascular and ventilatory adjustments. An exacerbate carotid chemosensory activity has been associated with human sympathetic-mediated diseases such as hypertension, insulin resistance, heart failure and obstructive sleep apnea (OSA. Indeed, the CB chemosensory discharge becomes tonically hypereactive in experimental models of OSA and heart failure. Chronic intermittent hypoxia (CIH, a main feature of OSA, enhances CB chemosensory baseline discharges in normoxia and in response to hypoxia, inducing sympathetic overactivity and hypertension. Oxidative stress, increased levels of ET-1, Angiotensin II and pro-inflammatory cytokines, along with a reduced production of NO in the CB, have been associated with the enhanced carotid chemosensory activity. In this review, we will discuss new evidence supporting a main role for the CB chemoreceptor in the autonomic and cardiorespiratory alterations induced by intermittent hypoxia, as well as the molecular mechanisms involved in the CB chemosensory potentiation.

  20. Enhanced carotid body chemosensory activity and the cardiovascular alterations induced by intermittent hypoxia

    Science.gov (United States)

    Iturriaga, Rodrigo; Andrade, David C.; Del Rio, Rodrigo

    2014-01-01

    The carotid body (CB) plays a main role in the maintenance of the oxygen homeostasis. The hypoxic stimulation of the CB increases the chemosensory discharge, which in turn elicits reflex sympathetic, cardiovascular, and ventilatory adjustments. An exacerbate carotid chemosensory activity has been associated with human sympathetic-mediated diseases such as hypertension, insulin resistance, heart failure, and obstructive sleep apnea (OSA). Indeed, the CB chemosensory discharge becomes tonically hypereactive in experimental models of OSA and heart failure. Chronic intermittent hypoxia (CIH), a main feature of OSA, enhances CB chemosensory baseline discharges in normoxia and in response to hypoxia, inducing sympathetic overactivity and hypertension. Oxidative stress, increased levels of ET-1, Angiotensin II and pro-inflammatory cytokines, along with a reduced production of NO in the CB, have been associated with the enhanced carotid chemosensory activity. In this review, we will discuss new evidence supporting a main role for the CB chemoreceptor in the autonomic and cardiorespiratory alterations induced by intermittent hypoxia, as well as the molecular mechanisms involved in the CB chemosensory potentiation. PMID:25520668

  1. Accuracy of Carotid Duplex Criteria in Diagnosis of Significant Carotid Stenosis in Asian Patients.

    Science.gov (United States)

    Dharmasaroja, Pornpatr A; Uransilp, Nattaphol; Watcharakorn, Arvemas; Piyabhan, Pritsana

    2018-03-01

    Extracranial carotid stenosis can be diagnosed by velocity criteria of carotid duplex. Whether they are accurately applied to define severity of internal carotid artery (ICA) stenosis in Asian patients needs to be proved. The purpose of this study was to evaluate the accuracy of 2 carotid duplex velocity criteria in defining significant carotid stenosis. Carotid duplex studies and magnetic resonance angiography were reviewed. Criteria 1 was recommended by the Society of Radiologists in Ultrasound; moderate stenosis (50%-69%): peak systolic velocity (PSV) 125-230 cm/s, diastolic velocity (DV) 40-100 cm/s; severe stenosis (>70%): PSV greater than 230 cm/s, DV greater than 100 cm/s. Criteria 2 used PSV greater than 140 cm/s, DV less than 110 cm/s to define moderate stenosis (50%-75%) and PSV greater than 140 cm/s, DV greater than 110 cm/s for severe stenosis (76%-95%). A total of 854 ICA segments were reviewed. There was moderate stenosis in 72 ICAs, severe stenosis in 50 ICAs, and occlusion in 78 ICAs. Criteria 2 had slightly lower sensitivity, whereas higher specificity and accuracy than criteria 1 were observed in detecting moderate stenosis (criteria 1: sensitivity 95%, specificity 83%, accuracy 84%; criteria 2: sensitivity 92%, specificity 92%, and accuracy 92%). However, in detection of severe ICA stenosis, no significant difference in sensitivity, specificity, and accuracy was found (criteria 1: sensitivity 82%, specificity 99.57%, accuracy 98%; criteria 2: sensitivity 86%, specificity 99.68%, and accuracy 99%). In the subgroup of moderate stenosis, the criteria using ICA PSV greater than 140 cm/s had higher specificity and accuracy than the criteria using ICA PSV 125-230 cm/s. However, there was no significant difference in detection of severe stenosis or occlusion of ICA. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. A rabbit model of atherosclerosis at carotid artery: MRI visualization and histopathological characterization

    International Nuclear Information System (INIS)

    Ma, Zhan-Long; Teng, Gao-Jun; Chen, Jun; Zhang, Hong-Ying; Cao, Ai-Hong; Ni, Yicheng

    2008-01-01

    To induce a rabbit model of atherosclerosis at carotid artery, to visualize the lesion evolution with magnetic resonance imaging (MRI), and to characterize the lesion types by histopathology. Atherosclerosis at the right common carotid artery (RCCA) was induced in 23 rabbits by high-lipid diet following balloon catheter injury to the endothelium. The rabbits were examined in vivo with a 1.5-T MRI and randomly divided into three groups of 6 weeks (n=6), 12 weeks (n=8) and 15 weeks (n=9) for postmortem histopathology. The lesions on both MRI and histology were categorized according to the American Heart Association (AHA) classifications of atherosclerosis. Type I and type II of atherosclerotic changes were detected at week 6, i.e., nearly normal signal intensity (SI) of the injured RCCA wall without stenosis on MRI, but with subendothelial inflammatory infiltration and proliferation of smooth muscle cells on histopathology. At week 12, 75.0% and 62.5% of type III changes were encountered on MRI and histopathology respectively with thicker injured RCCA wall of increased SI on T 1 -weighted and proton density (PD)-weighted MRI and microscopically a higher degree of plaque formation. At week 15, carotid atherosclerosis became more advanced, i.e., type IV and type V in 55.6% and 22.2% of the lesions with MRI and 55.6% and 33.3% of the lesions with histopathology, respectively. Statistical analysis revealed a significant agreement (p<0.05) between the MRI and histological findings for lesion classification (r=0.96). A rabbit model of carotid artery atherosclerosis has been successfully induced and noninvasively visualized. The atherosclerotic plaque formation evolved from type I to type V with time, which could be monitored with 1.5-T MRI and confirmed with histomorphology. This experimental setting can be applied in preclinical research on atherosclerosis. (orig.)

  3. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  4. Carotid artery stenting: Rationale, technique, and current concepts

    International Nuclear Information System (INIS)

    Yilmaz, Hasan; Pereira, Vitor Mendes; Narata, Ana-Paula; Sztajzel, Roman; Lovblad, Karl-Olof

    2010-01-01

    Carotid stenosis is a major risk factor for stroke. With the aging of the general population and the availability of non-invasive vascular imaging studies, the diagnosis of a carotid plaque is commonly made in medical practice. Asymptomatic and symptomatic carotid stenoses need to be considered separately because their natural history is different. Two large randomized controlled trials (RCTs) showed the effectiveness of carotid endarterectomy (CEA) in preventing ipsilateral ischemic events in patients with symptomatic severe stenosis. The benefit of surgery is much less for moderate stenosis and harmful in patients with stenosis less than 50%. Surgery has a marginal benefit in patients with asymptomatic stenosis. Improvements in medical treatment must be taken into consideration when interpreting the results of these previous trials which compared surgery against medical treatment available at the time the trials were conducted. Carotid artery stenting (CAS) might avoid the risks associated with surgery, including cranial nerve palsy, myocardial infarction, or pulmonary embolism. Therefore and additionally to well-established indications of CAS, this endovascular approach might be a valid alternative particularly in patients at high surgical risk. However, trials of endovascular treatment of carotid stenosis have failed to provide enough evidence to justify routine CAS as an alternative to CEA in patients suitable for surgery. More data from ongoing randomized trials of CEA versus CAS will be soon available. These results will help determining the role of CAS in the management of patients with carotid artery stenosis.

  5. Effect of Cervical Siphon of External and Internal Carotid Arteries.

    Science.gov (United States)

    Singh, Rajani; Tubbs, Richard Shane

    2017-10-01

    Variant courses, configuration, and branching pattern of the external and internal carotid arteries, especially when curved in S-shape, are important for hemodynamic changes and clinical implications. Therefore, the aim of the study is to report abnormal cervical siphons observed in external and internal carotid arteries to explore clinical significance by review of literature and hemodynamic changes theoretically.The right common carotid artery bifurcated into external and internal carotid arteries at the level of the upper border of thyroid cartilage in a 70-year-old female cadaver. After bifurcation, the external carotid artery underwent severe tortuosity coursing through 5 bends at points A, B, C, D, and E from its origin to termination and 2 bends at A' and B' in internal carotid artery in the cervical region. The angles between inflow and out flow of the blood at the bends were measured and the change in velocity at each bend was computed for both arteries. Hemodynamic changes were calculated, compared and relevant clinical complications were theoretically correlated.The angles of 20°, 30°, 51°, 52°, 60°, and 28°, 48° were formed by 5 bends of external and 2 bends of internal carotid arteries, respectively. The curved courses of these arteries caused reduction in velocity/stasis, turbulence, and low shear stress. Such kinks might cause stroke, ischemia and mistaken for tumors and abscess in imagery leading to or otherwise producing iatrogenic repercussions. This study will be useful for anatomists, clinicians, and radiologists.

  6. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  7. Carotid body size on CTA: Correlation with comorbidities

    International Nuclear Information System (INIS)

    Cramer, J.A.; Wiggins, R.H.; Fudim, M.; Engelman, Z.J.; Sobotka, P.A.; Shah, L.M.

    2014-01-01

    Aim: To test the hypothesis that computed tomographic angiography (CTA) can identify carotid body enlargement in patients with sympathetically mediated diseases. Materials and methods: A retrospective chart review of all patients obtaining CTAs of the cervical vasculature at University of Utah Health Sciences Center over a 6-month period was performed. Widest axial measurements of both carotid bodies were performed on a picture archiving and communication system (PACS). Statistical analysis was then performed to compare the mean carotid body size between control patients and patients with diabetes mellitus, hypertension, and congestive heart failure. Results: Measurements were performed on 288 patients, with 134 controls. Of the remaining 154, 72 patients had diabetes mellitus, 46 had congestive heart failure, and 130 had hypertension. The control patients had a mean carotid body diameter of 2.3 mm. There was a statistically significant (p < 0.01) 20–25% increase in mean diameter with diabetes mellitus (2.8 mm), hypertension (2.7 mm), and congestive heart failure (2.7 mm; p < 0.01). Conclusions: This study found a 20–25% larger mean carotid body size in patients with diabetes mellitus, hypertension, and congestive heart failure relative to controls. However, this small enlargement should not mimic other carotid body diseases, such as a paraganglionoma. Moreover, these findings further support the proposed functional relationship between the carotid body and sympathetically mediated disease states

  8. Diagnostic workup in carotid stenosis - a neurologist's perspective

    International Nuclear Information System (INIS)

    Rosenkranz, Michael; Gerloff, Christian

    2010-01-01

    Carotid artery stenosis is associated with the risk of stroke, myocardial infarction, and vascular death. In selected patients, revascularization of carotid narrowing by endarterectomy may reduce the risk of stroke distal to the stenosis. Carotid artery stenting has evolved as a potential alternative to endarterectomy. Four randomized clinical trials comparing safety and efficacy of endarterectomy versus stenting of symptomatic carotid stenosis have been published in recent years, but there remains some uncertainty about the implications of these trials for clinical routine. Both carotid stenting and endarterectomy are based on different treatment strategies which may result in different specific risk factors associated with each procedure. Hence, the procedural risk of either modality varies not only with the skills of the surgeon or the interventionalist but may depend on patient characteristics. It appears that the most important question is not whether one revascularization modality is superior but for which patient one modality is better than the other. A comprehensive diagnostic workup of patients with carotid stenosis based on a broad panel of covariates that affect the risk of vascular events may improve selection of patients for carotid revascularization and may help to decide for whom one revascularization modality is likely to be better than the other. (orig.)

  9. Control of the sidewall angle of an absorber stack using the Faraday cage system for the change of pattern printability in EUVL

    Science.gov (United States)

    Jang, Il-Yong; Huh, Sung-Min; Moon, Seong-Yong; Woo, Sang-Gyun; Lee, Jin-Kwan; Moon, Sang Heup; Cho, HanKu

    2008-10-01

    A patterned TaN substrate, which is candidate for a mask absorber in extreme ultra-violet lithography (EUVL), was etched to have inclined sidewalls by using a Faraday cage system under the condition of a 2-step process that allowed the high etch selectivity of TaN over the resist. The sidewall angle (SWA) of the patterned substrate, which was in the shape of a parallelogram after etching, could be controlled by changing the slope of a substrate holder that was placed in the Faraday cage. The performance of an EUV mask, which contained the TaN absorber of an oblique pattern over the molybdenum/silicon multi-layer, was simulated for different cases of SWA. The results indicated that the optical properties, such as the critical dimension (CD), an offset in the CD bias between horizontal and vertical patterns (H-V bias), and a shift in the image position on the wafer, could be controlled by changing the SWA of the absorber stack. The simulation result showed that the effect of the SWA on the optical properties became more significant at larger thicknesses of the absorber and smaller sizes of the target CD. Nevertheless, the contrast of the aerial images was not significantly decreased because the shadow effect caused by either sidewall of the patterned substrate cancelled with each other.

  10. Study on the related factors influencing the formation of intra-aneurysmal thrombosis in the established side-wall aneurysmal model in canine

    International Nuclear Information System (INIS)

    Zhou Bing; Li Minghua; Wang Jianbo; Zhu Yueqi; Yuan Jianhua; Yu Wenqiang

    2011-01-01

    Objective: To analyze the related factors influencing the formation of intra-aneurysmal thrombosis (IAT) in the established side-wall aneurysmal model in canine, and to discuss the measures to prevent the occurrence of IAT. Methods: Twenty canines were randomly divided into 4 groups for building side-wall aneurysmal model: group A, vertical aneurysm without use of postoperative anticoagulation medication; group B, vertical aneurysm with use of postoperative anticoagulation medication; group C, oblique aneurysm without use of postoperative anticoagulation medication; and group D, oblique aneurysm with use of postoperative anticoagulation medication. Angiography was performed to evaluate the IAT. The potential related factors influencing the formation of IAT, including sex, age, operative time, aneurysmal morphology, postoperative anticoagulation medication and cervical hematoma, were statistically analysed with emphasis on aneurysmal morphology and the use of postoperative anticoagulation medication. The statistical software SPSS 12.0 was employed. Results: A total of 40 aneurysms were successfully established in 20 canines. Cervical hematoma occurred in 7 canines and IAT developed in 8 aneurysms. The univariate analysis showed that the formation of IAT was significantly influenced by the aneurysmal morphology and cervical hematoma. Surprisingly, the formation of IAT bore no relation to the postoperative anticoagulation, whether the medication was employed or not, which was further confirmed by stratified analysis. Conclusion: To establish oblique aneurysm and to reduce the occurrence of cervical hematoma can effectively decrease the incidence of IAT in established side-wall aneurysmal model in canine. The postoperative anticoagulation medication can not decrease the incidence of IAT. (authors)

  11. Angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid artery

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Han, Moon Hee; Chang, Kee Hyun; Han, Gi Seok; Yeon, Kung Mo

    1995-01-01

    The purpose of this study is to describe the angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid arteries and to evaluate the extent of angiographic assessment needed before embolization. We retrospectively reviewed 10 cervicofacial vascular lesions with previously ligated carotid artery, which were 6 cases of arteriovenous malformation, 2 cases of carotid cavernous fistula, 1 case of hemangioma and 1 case of arteriovenous malformation with carotid cavernous fistula. The previously ligated arteries are proximal external carotid artery (n = 5), branches of external carotid artery (n = 2) and common carotid artery (n = 3). Common carotid artery or internal carotid artery (n = 9), vertebral artery (n = 5), ipsilateral external carotid artery (n = 4), contralateral external carotid artery (n = 5), costocervical trunk (n = 2), thyrocervical trunk (n = 2) were assessed by conventional angiography. Angiography of both carotid and vertebral arteries was performed in 5 cases. The collateral vascular channels were inferolateral trunk of internal carotid artery (n = 8), vertebral artery (n = 5), contralateral external carotid artery (n = 5), ipsilateral external carotid artery (n = 4), deep cervical artery (n = 2) and ascending cervical artery (n = 1). Embolization were performed in 9 cases with operative cannulation (n = 4), embolization via collateral branches of ipsilateral external carotid artery (n = 1), embolization via collateral branches of contralateral external carotid artery (n = 3) and balloon occlusion via direct puncture (n = 1). The collateral channels in cervicofacial vascular lesions with previously ligated carotid artery were inferolateral trunk of internal carotid artery, contralateral or ipsilateral external carotid artery, vertebral artery, deep cervical artery and ascending cervical artery on angiography. Complete angiographic assessment of possible collateral channels is mandatory for the

  12. Hydrocortisone supresses inflammatory activity of metalloproteinase - 8 in carotid plaque

    Science.gov (United States)

    Gabriel, Sthefano Atique; Antonangelo, Leila; Capelozzi, Vera Luiza; Beteli, Camila Baumann; de Camargo Júnior, Otacílio; de Aquino, José Luis Braga; Caffaro, Roberto Augusto

    2015-01-01

    Objective Matrix metalloproteinases are inflammatory biomarkers involved in carotid plaque instability. Our objective was to analyze the inflammatory activity of plasma and carotid plaque MMP-8 and MMP-9 after intravenous administration of hydrocortisone. Methods The study included 22 patients with stenosis ≥ 70% in the carotid artery (11 symptomatic and 11 asymptomatic) who underwent carotid endarterectomy. The patients were divided into two groups: Control Group - hydrocortisone was not administered, and Group 1 - 500 mg intravenous hydrocortisone was administered during anesthetic induction. Plasma levels of MMP-8 and MMP-9 were measured preoperatively (24 hours before carotid endarterectomy) and at 1 hour, 6 hours and 24 hours after carotid endarterectomy. In carotid plaque, tissue levels of MMP-8 and MMP-9 were measured. Results Group 1 showed increased serum levels of MMP- 8 (994.28 pg/ml and 408.54 pg/ml, respectively; P=0.045) and MMP-9 (106,656.34 and 42,807.69 respectively; P=0.014) at 1 hour after carotid endarterectomy compared to the control group. Symptomatic patients in Group 1 exhibited lower tissue concentration of MMP-8 in comparison to the control group (143.89 pg/ml and 1317.36 respectively; P=0.003). There was a correlation between preoperative MMP-9 levels and tissue concentrations of MMP-8 (P=0.042) and MMP-9 (P=0.019) between symptomatic patients in the control group. Conclusion Hydrocortisone reduces the concentration of MMP- 8 in carotid plaque, especially in symptomatic patients. There was an association between systemic and tissue inflammation. PMID:26313719

  13. External Carotid-Internal Jugular Fistula as a Late Complication After Carotid Endarterectomy: A Rare Case

    International Nuclear Information System (INIS)

    Bakar, Bulent; Cekirge, Saruhan; Tekkok, Ismail Hakki

    2011-01-01

    A 66-year-old man presented with mild amnesia, progressive fatigue, ataxia, visual hallucinations, and debility. His past medical history included right-sided carotid endarterectomy performed elsewhere 6 years previously. Cranial magnetic resonance imaging showed left parieto-occipital arteriovenous malformation-like tortous vessels, venous congestion, and ischemic areas. Cerebral angiography showed right-sided compound external carotid artery-internal jugular vein (IJV) fistula, and distal occlusion of the right IJV. Transvenous embolization via contralateral IJV was performed, and the fistula, together with fistulous portion of the distal IJV, was sealed using coils. Two years later, patient is well with normal neurologic examination findings. The presence of an arteriovenous communication after vascular surgery is a serious complication with potential long-term effects and therefore should be diagnosed and treated as promptly as possible.

  14. Unilateral Carotid Body Resection in Resistant Hypertension

    Directory of Open Access Journals (Sweden)

    Krzysztof Narkiewicz, MD

    2016-08-01

    Full Text Available Animal and human data indicate pathological afferent signaling emanating from the carotid body that drives sympathetically mediated elevations in blood pressure in conditions of hypertension. This first-in-man, proof-of-principle study tested the safety and feasibility of unilateral carotid body resection in 15 patients with drug-resistant hypertension. The procedure proved to be safe and feasible. Overall, no change in blood pressure was found. However, 8 patients showed significant reductions in ambulatory blood pressure coinciding with decreases in sympathetic activity. The carotid body may be a novel target for treating an identifiable subpopulation of humans with hypertension.

  15. Measurement of carotid bifurcation pressure gradients using the Bernoulli principle.

    Science.gov (United States)

    Illig, K A; Ouriel, K; DeWeese, J A; Holen, J; Green, R M

    1996-04-01

    Current randomized prospective studies suggest that the degree of carotid stenosis is a critical element in deciding whether surgical or medical treatment is appropriate. Of potential interest is the actual pressure drop caused by the blockage, but no direct non-invasive means of quantifying the hemodynamic consequences of carotid artery stenoses currently exists. The present prospective study examined whether preoperative pulsed-Doppler duplex ultrasonographic velocity (v) measurements could be used to predict pressure gradients (delta P) caused by carotid artery stenoses, and whether such measurements could be used to predict angiographic percent diameter reduction. Preoperative Doppler velocity and intraoperative direct pressure measurements were obtained, and per cent diameter angiographic stenosis measured in 76 consecutive patients who underwent 77 elective carotid endarterectomies. Using the Bernoulli principle (delta P = 4v(2), pressure gradients across the stenoses were calculated. The predicted delta P, as well as absolute velocities and internal carotid artery/common carotid velocity ratios were compared with the actual delta P measured intraoperatively and with preoperative angiography and oculopneumoplethysmography (OPG) results. An end-diastolic velocity of > or = 1 m/s and an end-diastolic internal carotid artery/common carotid artery velocity ratio of > or = 10 predicted a 50% diameter angiographic stenosis with 100% specificity. Although statistical significance was reached, preoperative pressure gradients derived from the Bernoulli equation could not predict actual individual intraoperative pressure gradients with enough accuracy to allow decision making on an individual basis. Velocity measurements were as specific and more sensitive than OPG results. Delta P as predicted by the Bernoulli equation is not sufficiently accurate at the carotid bifurcation to be useful for clinical decision making on an individual basis. However, end

  16. Increased YKL-40 expression in patients with carotid atherosclerosis

    DEFF Research Database (Denmark)

    Michelsen, Axel Gottlieb; Rathcke, C.N.; Skjelland, M.

    2010-01-01

    atherosclerosis and 20 healthy controls. Carotid expression of YKL-40 was examined by real time RT-PCR in 57 of the patients. Regulation and effect of YKL-40 were examined in THP-1 monocytes. Results: Our main findings were: (1) serum YKL-40 levels were significantly elevated in patients with carotid...... atherosclerosis, with particularly high levels in those with symptomatic disease; (2) patients with recent ischemic symptoms (within 2 months) had higher YKL-40 mRNA levels in carotid plaque than other patients; (3) in vitro, the beta-adrenergic receptor agonist isoproterenol, toll-like receptor (TLR) 2 and TLR4...

  17. Carotid endarterectomy in cervical block anesthesia in patients with occluded contralateral internal carotid artery

    Directory of Open Access Journals (Sweden)

    Ilijevski Nenad

    2006-01-01

    Full Text Available Introduction: The goal of modern carotid surgery is relief of symptoms, stroke prevention, improvement in quality of life, prevention of vascular dementia, and prolongation of lifetime. OBJECTIVE: The objective of this paper was to compare the outcome of carotid endarterectomy in cervical block vs. general anesthesia in patients with occluded contralateral internal carotid artery (ICA. METHOD: One hundred patients (76 male, 24 female, mean age 60.81 years with occluded contralateral ICA were operated from 1997-2000. Neurological symptomatology, deficiency and stroke incidence were preoperatively analyzed in two groups. Duplex-scanning, angiograms and CT-scan confirmed the diagnosis. Risk factors analysis included hypertension, diabetes, lipid metabolism disorders, smoking and history of CAD, CABG and PAOD. Morbidity and mortality were used to compare the outcome of surgery in two groups. RESULTS There was no difference of age, gender and symptomatology between the groups. Paresis, TIA and dysphasia were most frequent. 70%-90% of ICA stenosis was seen in the majority of patients. Hypertension and smoking were dominant risk factors in these two groups. Eversion carotid end arterectomy was the most frequent technique used. In three cases out of nine that were operated under cervical block, the neurological symptoms developed just after clamping, so the intra-luminal shunt was placed. Postoperative morbidity was 12% and mortality was 8%. Conclusion: There was no difference of preoperative parameters, surgical technique and outcome in these two groups. Without other intraoperative monitoring, cervical block anesthesia might be an option in patients with the occlusion of the contralateral ICA. However, prospective studies involving more patients are needed.

  18. Ischemic stroke: carotid and vertebral artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Vilela, P.; Goulao, A. [Hospital Garcia de Orta, Servico de Neurorradiologia, Almada (Portugal)

    2005-03-01

    Ischemic strokes may have distinct aetiologies, including several different intrinsic arterial pathological disorders. The diagnosis and understanding of these arterial diseases is critical for the correct management of stroke as different treatment approaches are undertaken according to the aetiology. Atherosclerosis is by far the most common arterial disease among adults, and other pathological processes include arterial dissection, small vessel disease, inflammatory and non-inflammatory vasculopathy and vasomotor disorders. In children, there are several vasculopathies responsible for vaso-occlusive disease such as sickle-cell anemia, acute regressive angiopathy and Moya-Moya disease, neurofibromatosis, dissections, vasculitis associated with intracranial and systemic infections. An overview of the major carotid and vertebral pathological diseases responsible for ischemic stroke in adults and children, highlighting the accuracy of the different imaging modalities for its diagnosis and the imaging appearance of these diseases, is given. (orig.)

  19. Extracranial internal carotid artery aneurysm: case illustration

    Directory of Open Access Journals (Sweden)

    Zenteno Marco

    2017-12-01

    Full Text Available Extracranial internal carotid artery aneurysms (EICAA are uncommon lesion. These aneurysms can be classified as true or false aneurysms, atherosclerotic, dysplastic, infectious, posttraumatic and iatrogenic aneurysms. The most common presentation is central neurologic dysfunction, either a stroke or a transient ischemic attack. The rupture of these aneurysms can lead to severely impairment and can affect the quality of life of the patients or even may lead to death. Management of these lesions is required in most cases to prevent complications, however there is no treatment guideline or expert consensus for the management. We present a case of an unusual EICAA, associated with kinking of the affected vessel and review the literature.

  20. Ischemic stroke: carotid and vertebral artery disease

    International Nuclear Information System (INIS)

    Vilela, P.; Goulao, A.

    2005-01-01

    Ischemic strokes may have distinct aetiologies, including several different intrinsic arterial pathological disorders. The diagnosis and understanding of these arterial diseases is critical for the correct management of stroke as different treatment approaches are undertaken according to the aetiology. Atherosclerosis is by far the most common arterial disease among adults, and other pathological processes include arterial dissection, small vessel disease, inflammatory and non-inflammatory vasculopathy and vasomotor disorders. In children, there are several vasculopathies responsible for vaso-occlusive disease such as sickle-cell anemia, acute regressive angiopathy and Moya-Moya disease, neurofibromatosis, dissections, vasculitis associated with intracranial and systemic infections. An overview of the major carotid and vertebral pathological diseases responsible for ischemic stroke in adults and children, highlighting the accuracy of the different imaging modalities for its diagnosis and the imaging appearance of these diseases, is given. (orig.)

  1. Magnetic Resonance angiography for carotid disease

    International Nuclear Information System (INIS)

    Dolz, J.L.; Begue, R.; Vilanova, J.C.; Aldama, J.; Delgado, E.; Baquero, M.; Capdevila, A.; Gili, J.

    1995-01-01

    Until now, patients with extracranial cerebrovascular ischemia (ECVI) could only be studied by means of CT, which provides reliable information on the parenchyma, but is unable to assess the intracranial vessels. On the other hand, angiographic and Doppler Us studies, which reflect the underlying vascular pathology and are considered reference explorations, with clearly established levels of sensitivity and specificity, are useless in the evaluation of the parenchyma. The introduction of MR and the development of MR angiographic (MRA) sequences lends a new dimension to the study of vascular disease. The knowledge and capacity to recognize the different artefacts or sources of error in MRA images, as well as the generalization of its use offer interesting expectations for its development as a technique for the entire study of the ischemic patient. We present selected illustrations of the vascular (carotid) disease obtained from 1400 cases studied in our center from June 1993 to the present (table I)

  2. Effective imaging of carotid artery dissection

    International Nuclear Information System (INIS)

    Obradovis, G.

    1997-01-01

    Angiography has been the gold standard in the diagnosis of arterial dissection for many years. With recent advances in techniques, particularly in MRI it may be worthy to re-evaluate the imaging methods available in obtaining the most information to maxims the patients' level of management. Assessing the imaging methods used in four patients with clinically suspected carotid artery dissection may reveal the most appropriate clinical pathway in managing these types of patients. In today's economic environment, we are striving for the most cost-effective imaging methods combined with the least invasive and safest. We must also review the cost benefit analysis of CT, angiography (DSA), Doppler Ultrasound and MRI/MRA. It is not within the scope of this paper to argue the merits of each imaging method, but purely to present some of the benefits in using non-invasive techniques if the clinical indications warrant them and they are available. (author)

  3. Carotid DSA based CFD simulation in assessing the patient with asymptomatic carotid stenosis: a preliminary study.

    Science.gov (United States)

    Zhang, Dong; Xu, Pengcheng; Qiao, Hongyu; Liu, Xin; Luo, Liangping; Huang, Wenhua; Zhang, Heye; Shi, Changzheng

    2018-03-12

    Cerebrovascular events are frequently associated with hemodynamic disturbance caused by internal carotid artery (ICA) stenosis. It is challenging to determine the ischemia-related carotid stenosis during the intervention only using digital subtracted angiography (DSA). Inspired by the performance of well-established FFRct technique in hemodynamic assessment of significant coronary stenosis, we introduced a pressure-based carotid arterial functional assessment (CAFA) index generated from computational fluid dynamic (CFD) simulation in DSA data, and investigated its feasibility in the assessment of hemodynamic disturbance preliminarily using pressure-wired measurement and arterial spin labeling (ASL) MRI as references. The cerebral multi-delay multi-parametric ASL-MRI and carotid DSA including trans-stenotic pressure-wired measurement were implemented on a 65-year-old man with asymptomatic unilateral (left) ICA stenosis. A CFD simulation using simplified boundary condition was performed in DSA data to calculate the CAFA index. The cerebral blood flow (CBF) and arterial transit time (ATT) of ICA territories were acquired. CFD simulation showed good correlation (r = 0.839, P = 0.001) with slight systematic overestimation (mean difference - 0.007, standard deviation 0.017) compared with pressure-wired measurement. No significant difference was observed between them (P = 0.09). Though the narrowing degree of in the involved ICA was about 70%, the simulated and measured CAFA (0.942/0.937) revealed a functionally nonsignificant stenosis which was also verified by a compensatory final CBF (fronto-temporal/fronto-parietal region: 51.58/45.62 ml/100 g/min) and slightly prolonged ATT (1.23/1.4 s) in the involved territories, together with a normal left-right percentage difference (2.1-8.85%). The DSA based CFD simulation showed good consistence with invasive approach and could be used as a cost-saving and efficient way to study the relationship between

  4. Prediction of fibre architecture and adaptation in diseased carotid bifurcations.

    LENUS (Irish Health Repository)

    Creane, Arthur

    2011-12-01

    Many studies have used patient-specific finite element models to estimate the stress environment in atherosclerotic plaques, attempting to correlate the magnitude of stress to plaque vulnerability. In complex geometries, few studies have incorporated the anisotropic material response of arterial tissue. This paper presents a fibre remodelling algorithm to predict the fibre architecture, and thus anisotropic material response in four patient-specific models of the carotid bifurcation. The change in fibre architecture during disease progression and its affect on the stress environment in the plaque were predicted. The mean fibre directions were assumed to lie at an angle between the two positive principal strain directions. The angle and the degree of dispersion were assumed to depend on the ratio of principal strain values. Results were compared with experimental observations and other numerical studies. In non-branching regions of each model, the typical double helix arterial fibre pattern was predicted while at the bifurcation and in regions of plaque burden, more complex fibre architectures were found. The predicted change in fibre architecture in the arterial tissue during plaque progression was found to alter the stress environment in the plaque. This suggests that the specimen-specific anisotropic response of the tissue should be taken into account to accurately predict stresses in the plaque. Since determination of the fibre architecture in vivo is a difficult task, the system presented here provides a useful method of estimating the fibre architecture in complex arterial geometries.

  5. Role of Carotid Body in Intermittent Hypoxia-Related Hypertension.

    Science.gov (United States)

    Iturriaga, Rodrigo; Oyarce, María Paz; Dias, Ana Carolina Rodrigues

    2017-05-01

    Obstructive sleep apnea (OSA), a common breathing disorder, is recognized as an independent risk factor for systemic hypertension. Among the alterations induced by OSA, the chronic intermittent hypoxia (CIH) is considered the main factor for the hypertension. Exposure of rodents to CIH is the gold-standard method to study the mechanisms involved in the cardiovascular alterations induced by OSA. Although it is well known that CIH produces hypertension, the underlying mechanisms are not totally elucidated. It is likely that the CIH-induced systemic oxidative stress and inflammation may elicit endothelial dysfunction and increase the arterial blood pressure. In addition, OSA patients and animals exposed to CIH show sympathetic hyperactivity and potentiated cardiorespiratory responses to acute hypoxia, suggesting that CIH enhances the peripheral hypoxic chemoreflex. Recent experimental evidences support the proposal that CIH selectively enhances carotid body (CB) chemosensory reactivity to oxygen, which in turn increases sympathetic outflow leading to neurogenic hypertension. In this review, we will discuss the supporting evidence for a critical role of the CB in the generation and maintenance of the hypertension induced by CIH, also, the contribution of oxidative stress to enhance CB chemosensory drive and the activation of sympathetic-related centers in the brain.

  6. Dynamic Analysis of the Carotid-Kundalini Map

    Science.gov (United States)

    Wang, Xingyuan; Liang, Qingyong; Meng, Juan

    The nature of the fixed points of the Carotid-Kundalini (C-K) map was studied and the boundary equation of the first bifurcation of the C-K map in the parameter plane is presented. Using the quantitative criterion and rule of chaotic system, the paper reveals the general features of the C-K Map transforming from regularity to chaos. The following conclusions are obtained: (i) chaotic patterns of the C-K map may emerge out of double-periodic bifurcation; (ii) the chaotic crisis phenomena are found. At the same time, the authors analyzed the orbit of critical point of the complex C-K Map and put forward the definition of Mandelbrot-Julia set of the complex C-K Map. The authors generalized the Welstead and Cromer's periodic scanning technique and using this technology constructed a series of the Mandelbrot-Julia sets of the complex C-K Map. Based on the experimental mathematics method of combining the theory of analytic function of one complex variable with computer aided drawing, we investigated the symmetry of the Mandelbrot-Julia set and studied the topological inflexibility of distribution of the periodic region in the Mandelbrot set, and found that the Mandelbrot set contains abundant information of the structure of Julia sets by finding the whole portray of Julia sets based on Mandelbrot set qualitatively.

  7. Computational model of collagen turnover in carotid arteries during hypertension.

    Science.gov (United States)

    Sáez, P; Peña, E; Tarbell, J M; Martínez, M A

    2015-02-01

    It is well known that biological tissues adapt their properties because of different mechanical and chemical stimuli. The goal of this work is to study the collagen turnover in the arterial tissue of hypertensive patients through a coupled computational mechano-chemical model. Although it has been widely studied experimentally, computational models dealing with the mechano-chemical approach are not. The present approach can be extended easily to study other aspects of bone remodeling or collagen degradation in heart diseases. The model can be divided into three different stages. First, we study the smooth muscle cell synthesis of different biological substances due to over-stretching during hypertension. Next, we study the mass-transport of these substances along the arterial wall. The last step is to compute the turnover of collagen based on the amount of these substances in the arterial wall which interact with each other to modify the turnover rate of collagen. We simulate this process in a finite element model of a real human carotid artery. The final results show the well-known stiffening of the arterial wall due to the increase in the collagen content. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Pulp Stone, Haemodialysis, End-stage Renal Disease, Carotid Atherosclerosis

    OpenAIRE

    Patil, Santosh; Sinha, Nidhi

    2013-01-01

    Objectives: The aim of this study was to determine the relationship between the presence of pulp calcification and carotid artery calcification on the dental panoramic radiographs in End Stage Renal Disease (ESRD) patients who were on haemodialysis.

  9. An unusual case of common carotid artery pseudoaneurysm caused ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    pseudoaneurysm involving the right common carotid artery. Sewing needle ( ... displacement of tracheal shadow towards the left ... CT scan of brain was not done in this case as there are no .... function and allergies to CT contrast material12.

  10. Carotid body tumor imitator: An interesting case of Castleman's disease.

    Science.gov (United States)

    Shakir, Hakeem J; Diletti, Sara M; Hart, Alexandra M; Meyers, Joshua E; Dumont, Travis M; Siddiqui, Adnan H

    2015-01-01

    There are very few reports in the literature of Castleman's disease affecting the carotid artery and a single previous report of a case of Castleman's disease of the neck originally mistaken as a carotid body tumor. We describe a rare case of Castleman's disease, manifesting with classic radiographic hallmarks of a carotid body tumor. The postoperative pathologic examination identified the resected mass as Castleman's lymphadenopathy. The management of this particular case is discussed, and the findings are highlighted. We present a unique case of a tumor initially and incorrectly diagnosed as a carotid body tumor. However, after comprehensive treatment with endovascular and surgical modalities and subsequent pathologic examination, the diagnosis of this rare entity was made.

  11. Cone pathway function in relation to asymmetric carotid artery stenosis

    DEFF Research Database (Denmark)

    Kofoed, Peter Kristian; Munch, Inger Christine; Holfort, Stig K

    2013-01-01

    Purpose:  To examine retinal function in relation to retinal perfusion pressure in patients with carotid artery stenosis. Methods:  Thirteen patients with carotid artery stenosis without clinical eye disease underwent assessment of ophthalmic artery systolic blood pressure (OSP) by ocular...... pneumoplethysmography, carotid artery obstructive disease by ultrasonography, intraocular pressure by applanation tonometry, retinal perfusion by fluorescein angiography and retinal function by multifocal electroretinography (mfERG). Data analysis compared the eye on the most stenotic side with the fellow eye...... pressure (p = 0.0028, 0.011, 0.041 for N1, P1, N2 implicit times, respectively, and p = 0.0086, 0.016, 0.040 for N1, P1, N2 for amplitudes, respectively, corrected for OSP). Conclusion:  Cone function deviation was observed in clinically healthy eyes on the side with highest degree of carotid artery...

  12. Treatment of a symptomatic intrathoracic internal carotid artery

    Directory of Open Access Journals (Sweden)

    Christopher R. Brown

    2017-09-01

    Full Text Available Intrathoracic common carotid artery bifurcations are an anatomic anomaly with such rarity that only six cases have been reported to date. The true incidence of and preferred treatment options for a diseased intrathoracic common carotid artery bifurcation or internal carotid artery (ICA have not been clearly described. This case report describes a 72-year-old man who experienced a postoperative right hemispheric stoke after an aortic valve replacement, radiofrequency maze procedure, and left atrial appendage clip. Postoperative cerebrovascular evaluation revealed a severely diseased intrathoracic ICA that was treated by ligation of the diseased proximal ICA and transposition of the distal ICA to the disease-free external carotid artery. The patient provided written consent to present the history, data, and images in this manuscript.

  13. Emergency treatment by intravascular embolization in traumatic carotid cavernous fistula

    International Nuclear Information System (INIS)

    Tang Jun; Sun Zengtao; Liu Zuoqin; Liu Yanjun; Li Fengxin

    2006-01-01

    Objective: To discuss the method of intervenfional intravascular treatment in traumatic carotid cavernous fistula (TCCF) and the significance of clinical application in emergency. Methods: In 297 eases of TCCF, 36 cases were treated by interventional intravascular embolization by detachable balloon, embolization orificium or occlusion in one side of carotid artery. In the 36 cases, serious epistaxis occurred in 22 eases, cortical vein inflow in 9 cases, intracranial hemorrhage in 3 cases, aggravation of eyesight in 3 cases, and limb dysfunction in 2 cases. Results: Fistula was successfully embolized and internal carotid artery remained patent in 19 cases. Complete embolization of orificium or internal carotid artery was achieved in 17 eases. The serious epistaxias in 22 cases and intracranial hemorrhage in 3 cases stopped. Eyesight recovered in 2 eases and improved in 1 case. Limb dysfunction improved evidently in 2 cases. Conclusion: Intravascular embolization treatment is the first therapeutic choice for TCCF, especially in emergency. It is necessary, safe and effective. (authors)

  14. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial

    NARCIS (Netherlands)

    Bonati, L.H.; Dobson, J.; Featherstone, R.L.; Ederle, J.; Worp, H.B. van der; Borst, G.J. de; Mali, W.P.; Beard, J.D.; Cleveland, T.; Engelter, S.T.; Lyrer, P.A.; Ford, G.A.; Dorman, P.J.; Brown, M.M.; Leeuw, F.E. de; et al.,

    2015-01-01

    BACKGROUND: Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. METHODS: Patients with symptomatic carotid

  15. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial

    NARCIS (Netherlands)

    Bonati, Leo H.; Dobson, Joanna; Featherstone, Roland L.; Ederle, Jörg; van der Worp, H. Bart; de Borst, Gert J.; Mali, Willem P. Th M.; Beard, Jonathan D.; Cleveland, Trevor; Engelter, Stefan T.; Lyrer, Philippe A.; Ford, Gary A.; Dorman, Paul J.; Brown, Martin M.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Coward, L.; Dobson, J.; Doig, D.; Ederle, J.; Featherstone, R. F.; Kennedy, F.; Tindall, H.; Turner, E.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Koelemay, M. J. W.; Nederkoorn, P. J.; Reekers, J. A. A.; Roos, Y. B. W. E. M.

    2015-01-01

    Background Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. Methods Patients with symptomatic carotid stenosis

  16. Guidelines for patient selection and performance of carotid artery stenting.

    Science.gov (United States)

    Bladin, Christopher; Chambers, Brian; New, Gishel; Denton, Michael; Lawrence-Brown, Michael

    2010-06-01

    The endovascular treatment of carotid atherosclerosis with carotid artery stenting (CAS) remains controversial. Carotid endarterectomy remains the benchmark in terms of procedural mortality and morbidity. At present, there are no consensus Australasian guidelines for the safe performance of CAS. We applied a modified Delphi consensus method of iterative consultation between the College representatives on the Carotid Stenting Guidelines Committee (CSGC). Selection of patients suitable for CAS needs careful consideration of clinical and patho-anatomical criteria and cannot be directly extrapolated from clinical indicators for carotid endarterectomy (CEA). Randomized controlled trials (including pooled analyses of results) comparing CAS with CEA for treatment of symptomatic stenosis have demonstrated that CAS is more hazardous than CEA. On current evidence, the CGSC therefore recommends that CAS should not be performed in the majority of patients requiring carotid revascularisation. The evidence for CAS in patients with symptomatic severe carotid stenosis who are considered medically high risk is weak, and there is currently no evidence to support CAS as a treatment for asymptomatic carotid stenosis. The use of distal protection devices during CAS remains controversial with increased risk of clinically silent stroke. The knowledge requirements for the safe performance of CAS include an understanding of the evidence base from randomized controlled trials, carotid and aortic arch anatomy and pathology, clinical stroke syndromes, the differing treatment options for stroke and carotid atherosclerosis, and recognition and management of periprocedural complications. It is critical that all patients being considered for a carotid intervention have adequate pre-procedural neuro-imaging and an independent, standardized neurological assessment before and after the procedure. Maintenance of proficiency in CAS requires active involvement in surgical/endovascular audit and

  17. Spontaneous carotid artery dissection causing a juvenile cerebral infarction

    International Nuclear Information System (INIS)

    Trattnig, S.; Huebsch, P.; Schindler, E.

    1988-01-01

    The case of a 19-year-old patient is presented who was admitted with aphasia and hemiparesis due to basal ganglia infarction as a result of spontaneous dissection of the internal carotid artery. The difficulties in diagnosing this disease with CT and MRI in the acute stage are demonstrated. Angiography is still imperative in order to ascertain that a carotid dissection has occurred. (orig.) [de

  18. Asymptomatic internal carotid artery stenosis and cerebrovascular risk stratification

    DEFF Research Database (Denmark)

    Nicolaides, Andrew N; Kakkos, Stavros K; Kyriacou, Efthyvoulos

    2010-01-01

    The purpose of this study was to determine the cerebrovascular risk stratification potential of baseline degree of stenosis, clinical features, and ultrasonic plaque characteristics in patients with asymptomatic internal carotid artery (ICA) stenosis.......The purpose of this study was to determine the cerebrovascular risk stratification potential of baseline degree of stenosis, clinical features, and ultrasonic plaque characteristics in patients with asymptomatic internal carotid artery (ICA) stenosis....

  19. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  20. Common carotid artery thrombosis; Clinical and radiological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Yasuhiro; Yasuda, Takeshi; Hakusui, Shigetaka; Yanagi, Tsutomu (Nagoya Daini Red Cross Hospital (Japan)); Ito, Eiichi

    1994-02-01

    Common carotid artery thrombosis (CCAT) is not common. We studied 4 patients with CCAT to clarify the clinical and radiological features of this disorder. Case 1 had only episodes of TIA. Case 2 was diagnosed by chance as having CCAT at the time of admission due to cerebellar infarction. On the contrary, Cases 3 and 4 were admitted because of disturbance of consciousness and hemiparesis. Case 4 died soon after his stroke because of complications. We evaluated cases 1, 2 and 3 using head CT, head MRI, neck MRI, MR angiography, SPECT and cerebral angiography. Case 4, who was evaluated with head CT and cerebral angiography, was autopsied to confirm the occlusion of the common carotid artery. The clinical severity of CCAT varies from asymptomatic to severe, because each case differs in the time taken for complete occlusion of the common carotid artery; the development of collateral circulation; and hemodynamics of the brain. As for the collaterals their contribution is variable; for example, the thyrocervical and other arteries function as the bypass. We can diagnose CCAT easily and noninvasively using MR angiography and neck MRI based on disappearance of the flow void in the common carotid artery or internal carotid artery. On physical examination, it is important to detect faded pulsation of the superficial temporal artery that is ipsilateral to the occluded common carotid artery. (author).

  1. Carotid angioplasty and stenting under protection. Techniques, results and limitations.

    Science.gov (United States)

    Henry, M; Polydorou, A; Henry, I; Anagnostopoulou, I S; Polydorou, I A; Hugel, M

    2006-10-01

    A carotid stenosis is responsible for about 30% of strokes occurring. Carotid endarterectomy (CEA) is considered to be the gold standard treatment of a carotid stenosis. Carotid angioplasty and stenting (CAS) is emerging as a new alternative treatment for a carotid artery stenosis, but the risk of neurological complications and brain embolism remains the major drawback to this procedure. Therefore, in order to reduce the risks, we need: 1) good indications, good patient and lesion selection; 2) correct techniques; 3) brain protection devices (cerebral protection devices should be routinely used and are mandatory for any procedure); 4) 3 types of protection devices are available, but filters are the most commonly used (all protection devices have limitations and cannot prevent from all embolic events; however, neurological complications can be reduced by 60%); 5) a good choice of the stent and correct implantation (all stents are not equivalent and have different geometrical effects); 6) pharmacological adjuncts; 7) a good team. Recent studies have shown that CAS has superior short-term outcomes than CEA in high surgical risk patients, but there are enough reported data to conclude that CAS is also not inferior to CEA in low-risk patients. CAS under protection is the standard of care and is maybe becoming the gold standard treatment of a carotid stenosis at least in some subgroups of patients.

  2. Recommendations for Management of Patients with Carotid Stenosis

    Directory of Open Access Journals (Sweden)

    Arijana Lovrencic-Huzjan

    2012-01-01

    Full Text Available Stroke is a one of the leading causes of morbidity and mortality in the world. Carotid atherosclerosis is recognized as an important factor in stroke pathophysiology and represents a key target in stroke prevention; multiple treatment modalities have been developed to battle this disease. Multiple randomized trials have shown the efficacy of carotid endarterectomy in secondary stroke prevention. Carotid stenting, a newer treatment option, presents a less invasive alternative to the surgical intervention on carotid arteries. Advances in medical therapy have also enabled further risk reduction in the overall incidence of stroke. Despite numerous trials and decades of clinical research, the optimal management of symptomatic and asymptomatic carotid disease remains controversial. We will attempt to highlight some of the pivotal trials already completed, discuss the current controversies and complexities in the treatment decision-making, and postulate on what likely lies ahead. This paper will highlight the complexities of decision-making optimal treatment recommendations for patients with symptomatic and asymptomatic carotid stenosis.

  3. Efficacy of Surgical Therapy for Carotid Body Tumors

    Institute of Scientific and Technical Information of China (English)

    Li-shan Lian; Chang-wei Liu; Heng Guan; Yue-hong Zheng; Xing-ming Chen; Yong-jun Li

    2011-01-01

    Objective To evaluate the efficacy of surgical therapy for carotid body tumors.Methods A retrospective analysis was conducted,covering the diagnosis,surgical procedure,post-operative complications,and prognosis of 120 cases of carotid body tumors in Peking Union Medical College Hospital from 1949 to May,2011.Results Surgical excision was successfully performed in 111 cases with 117 tumors.In all those cases,50 underwent simple tumor resection,42 underwent resection of tumors and ligation of the external carotid arteries,7 underwent co-resection of tumors and common carotid arteries,internal carotid arteries,as well as external arteries without vascular reconstruction,and the other 12 cases experienced tumor resection and vascular reconstruction as internal carotid arteries were involved.After operation,3 cases developed cerebral infarction,30 cases showed cranial nerve palsy,including 15 cases of hypoglossal nerve damage,10 cases of vagus paralysis,and 5 cases of Horner's syndrome.Conclusion It is essential to make a proper surgical strategy,which can reduce postoperative complications.

  4. Estimated carotid-femoral pulse wave velocity has similar predictive value as measured carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Greve, Sara V; Blicher, Marie K; Kruger, Ruan

    2016-01-01

    BACKGROUND: Carotid-femoral pulse wave velocity (cfPWV) adds significantly to traditional cardiovascular risk prediction, but is not widely available. Therefore, it would be helpful if cfPWV could be replaced by an estimated carotid-femoral pulse wave velocity (ePWV) using age and mean blood pres...... that these traditional risk scores have underestimated the complicated impact of age and blood pressure on arterial stiffness and cardiovascular risk....

  5. Evidence for shear stress-mediated dilation of the internal carotid artery in humans

    DEFF Research Database (Denmark)

    Carter, Howard Henry; Atkinson, Ceri L; Heinonen, Ilkka H A

    2016-01-01

    -mediated dilation of larger conduit arteries in humans. There was a strong association between change in shear and diameter of the internal carotid (r=0.68; Ptime in humans, that shear stress is an important stimulus for hypercapnic vasodilation of the internal carotid...... increases carotid shear stress, a known stimulus to vasodilation in other conduit arteries. To explore the hypothesis that shear stress contributes to hypercapnic internal carotid dilation in humans, temporal changes in internal and common carotid shear rate and diameter, along with changes in middle.......01) carotids. Diameter also increased (Ptime course is associated with shear...

  6. Results of subclavian to carotid artery bypass for occlusive disease of the common carotid artery: A retrospective cohort study.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Calio, Francesco G; Masci, Federica; Pasqua, Rocco; Frezzotti, Francesca; Peschillo, Simone

    2018-05-01

    Optimal treatment of significant atherosclerosis of the common carotid artery (CCA) is not well-defined. The purpose of this study was to evaluate the long-term results of prosthetic subclavian to carotid bypass for occlusive disease of the CCA. From January 1994 to December 2015, 45 patients, mean age 67 years, underwent an ipsilateral subclavian to carotid bypass for occlusive disease of the CCA. Thirty-eight patients (84%) presented with neurologic symptoms, including transitory ischemic attacks in 29 cases and minor strokes in 9 cases. The graft material consisted of a 7 mm polytetrafluoroethylene conduit, and the distal anastomosis was done on the carotid bulb in 21 patients, on the internal carotid artery in 19 cases, and on the distal CCA in 5 cases. Median length of follow-up was 58 months. Study endpoints were the combined postoperative stroke/mortality rate, graft infection, overall late survival, freedom from ipsilateral stroke, and graft patency. Postoperative stroke/mortality rate was 2%. No graft infection was observed throughout follow-up. At 60 months, overall survival, freedom from stroke, and graft patency were 71% (standard error [SE] = 0.07), 98% (SE = 0.02), and 95.5% (SE = 0.06), respectively. Subclavian to carotid bypass allows very good patency rates and excellent protection from postoperative and late stroke, remaining a benchmark for any other treatment method. Copyright © 2018. Published by Elsevier Ltd.

  7. Carotid Artery Stenting in a Patient with Spontaneous Recanalization of a Proximal Internal Carotid Artery Occlusion: a Case Report

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Koh, Jun Seok; Choi, Woo Suk

    2006-01-01

    We report here on a rare case of carotid artery angioplasty and stenting in a patient with spontaneous recanalization after complete occlusion of the proximal internal carotid artery (ICA). The patient initially showed severe stenosis at the left proximal ICA on MR angiography (MRA). Digital subtraction angiography (DSA) performed three days after MRA showed complete occlusion of the proximal ICA. The follow-up DSA after four weeks showed recanalization of the ICA, and then carotid artery stenting was successfully performed. There has been no neurologic complication during more than one year follow-up. cute internal carotid artery (ICA) occlusions may result in profound disability and death (1). An occluded ICA can spontaneously recanalize, but this doesn't happen frequently, and the natural course of a proximal ICA occlusion and its possibility of recanalization, including the exact time of recanalization after occlusion, are not well known (2, 3). A few studies have reported the incidence of spontaneous recanalization of the proximal internal carotid artery, which has mostly occurred in patients with ICA dissections (4 6). A few limited studies have reported a considerable incidence of spontaneous recanalization in patients with underlying atherosclerotic lesion or atherothombotic diseases (2). The possibility of repeated occlusion and repeated cerebral ischemic infarction may exist for the patients exhibiting spontaneous recanalization of the ICA and underlying atherosclerosis. We report here on a case of carotid artery stenting (CAS) in a patient who exhibited underlying atherosclerosis with spontaneous recanalization after complete occlusion of the proximal ICA

  8. The usefulness of carotid sinus massage in different patient groups.

    Science.gov (United States)

    Kumar, Narasimhan Pradeep; Thomas, Alan; Mudd, Paul; Morris, Robert O; Masud, Tahir

    2003-11-01

    to determine the positive yield of carotid sinus massage in different patient groups: unexplained syncope, falls, dizziness and controls. observational study. teaching hospital. we studied consecutive patients over the age of 60 years referred to the 'falls clinic' with a history of unexplained syncope, unexplained falls and unexplained dizziness. We also studied asymptomatic control subjects recruited from a general practice register aged 60 years and over. All patients and control subjects underwent a full clinical assessment (comprehensive history and detailed clinical examination including supine and erect blood pressure measurements) and 12-lead electrocardiography. We performed carotid sinus massage in the supine position for 5 seconds separately on both sides followed by repeating the procedure in the upright positions using a motorised tilt table. Heart rate and blood pressure were recorded using a cardiac monitor and digital plethysmography respectively. The test was considered positive if carotid sinus massage produced asystole with more than a 3 second pause (cardioinhibitory type of carotid sinus syndrome), or a fall in systolic blood pressure of more than 50 mmHg in the absence of significant cardioinhibition (vasodepressor type of carotid sinus syndrome) or where there was evidence of both vasodepressor and cardio-inhibition as above (mixed type). we studied 44 asymptomatic control subjects and 221 symptomatic patients (130 with unexplained syncope, 41 with unexplained falls and 50 with unexplained dizziness). In the overall symptomatic patient group, the positive yield (any type of carotid sinus syndrome) was 17.6% (95% CI = 12.7-22.5). The positive yield in men (26.3% (95% CI = 16.4-36.2)) was twice that in women (13.1% (95% CI = 7.6-18.6)) (P = 0.014). Overall any type of carotid sinus syndrome was present in 22.3% (n = 29) of the syncope group, 17.1% (n = 7) in the unexplained fallers group and 6% (n = 3) in the dizziness group. We also found that

  9. Evaluation of polyethylene glycol/polylactic acid films in the prevention of adhesions in the rabbit adhesion formation and reformation sidewall models.

    Science.gov (United States)

    Rodgers, K; Cohn, D; Hotovely, A; Pines, E; Diamond, M P; diZerega, G

    1998-03-01

    To assess the efficacy of bioresorbable films consisting of various polyethylene glycol 6000 and polylactic acid block copolymers on the formation and reformation of adhesions in rabbit models of adhesion development between the sidewall to the adjacent cecum and bowel. The composition of the different polymers was expressed by the number of monomeric units in the block, namely, ethylene oxide (EO) and lactic acid (LA), respectively. Studies of the efficacy of EO/LA films were conducted in rabbit sidewall adhesion formation studies in the presence and absence of blood and in rabbit adhesion reformation studies. REPEL (Life Medical Sciences, Edison, NJ), a film of EO/LA ratio 3.0 manufactured under commercial conditions, was also tested in these animal models. University-based laboratory. New Zealand white rabbits. Placement of films of various EO/LA ratios at the site of injury to the parietal peritoneum. Adhesion formation and reformation. Films of various EO/LA ratios, Seprafilm (Genzyme, Cambridge, MA) and Interceed (Johnson and Johnson Medical, Arlington, TX) placed over an area of excised sidewall at the time of initial injury were highly efficacious in the prevention of adhesion formation. A film of EO/LA ratio 3.7, in contrast with Interceed, was also shown to maintain maximal efficacy in the reduction of adhesion formation in the presence of blood. Further, a film of EO/LA ratio 3.0 produced under commercial conditions, REPEL, was highly efficacious in reducing adhesion development in the rabbit models of adhesion and reformation. These studies suggest that bioresorbable EO/LA films reduced adhesion development in rabbit models of adhesion formation and reformation.

  10. Carotid artery protrusion and dehiscence in patients with acromegaly.

    Science.gov (United States)

    Sasagawa, Yasuo; Tachibana, Osamu; Doai, Mariko; Hayashi, Yasuhiko; Tonami, Hisao; Iizuka, Hideaki; Nakada, Mitsutoshi

    2016-10-01

    Acromegaly is a systemic disease which causes multiple bony alterations. Some authors reported that acromegalic patients have risk factors for an intraoperative vascular injury due to the specific anatomical features of their sphenoid sinus. The objective of our study was to analyze the anatomic characteristics of sphenoid sinus in acromegalic patients compared with controls, by evaluation of computed tomography (CT) findings. We examined 45 acromegalic (acromegaly group) and 45 non-acromegalic patients (control group) with pituitary adenomas who were matched for sex, age, height, tumor size, and cavernous sinus invasion (Knosp grade). Preoperative CT of the pituitary region including the sphenoid sinus was used to evaluate the following anatomic characteristics: type of sphenoid sinus (sellar or pre-sellar/conchal); intrasphenoid septa (non/single or multiple); carotid artery protrusion; carotid artery dehiscence; intercarotid distance. Sixteen acromegalic patients (35.5 %) and 6 controls (13.3 %) had carotid artery protrusion. Additionally, 10 acromegalic patients (22.2 %) and 3 controls (6.6 %) had carotid artery dehiscence. Carotid artery protrusion and dehiscence were more frequent in the acromegaly group than in control group (p = 0.013 and 0.035, respectively). Other anatomic characteristics (type of sphenoid sinus, intrasphenoid septa, and intracarotid distance) showed no significant differences between acromegaly and control groups. Our study suggests that carotid artery protrusion and dehiscence occur more frequently among acromegalic patients, compared with non-acromegalic patients. It is important for surgeons to be aware of these anatomic variations to avoid vital complications, such as carotid injuries, during surgery.

  11. National variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic carotid artery stenosis.

    Science.gov (United States)

    Arous, Edward J; Simons, Jessica P; Flahive, Julie M; Beck, Adam W; Stone, David H; Hoel, Andrew W; Messina, Louis M; Schanzer, Andres

    2015-10-01

    Carotid endarterectomy (CEA) for asymptomatic carotid artery stenosis is among the most common procedures performed in the United States. However, consensus is lacking regarding optimal preoperative imaging, carotid duplex ultrasound criteria, and ultimately, the threshold for surgery. We sought to characterize national variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic CEA. The Society for Vascular Surgery Vascular Quality Initiative (VQI) database was used to identify all CEA procedures performed for asymptomatic carotid artery stenosis between 2003 and 2014. VQI currently captures 100% of CEA procedures performed at >300 centers by >2000 physicians nationwide. Three analyses were performed to quantify the variation in (1) preoperative imaging, (2) carotid duplex ultrasound criteria, and (3) threshold for surgery. Of 35,695 CEA procedures in 33,488 patients, the study cohort was limited to 19,610 CEA procedures (55%) performed for asymptomatic disease. The preoperative imaging modality used before CEA varied widely, with 57% of patients receiving a single preoperative imaging study (duplex ultrasound imaging, 46%; computed tomography angiography, 7.5%; magnetic resonance angiography, 2.0%; cerebral angiography, 1.3%) and 43% of patients receiving multiple preoperative imaging studies. Of the 16,452 asymptomatic patients (89%) who underwent preoperative duplex ultrasound imaging, there was significant variability between centers in the degree of stenosis (50%-69%, 70%-79%, 80%-99%) designated for a given peak systolic velocity, end diastolic velocity, and internal carotid artery-to-common carotid artery ratio. Although 68% of CEA procedures in asymptomatic patients were performed for an 80% to 99% stenosis, 26% were performed for a 70% to 79% stenosis, and 4.1% were performed for a 50% to 69% stenosis. At the surgeon level, the range in the percentage of CEA procedures performed for a duplex ultrasound

  12. Histological analysis of extracranial carotid artery aneurysms.

    Directory of Open Access Journals (Sweden)

    Janna C Welleweerd

    Full Text Available Extracranial carotid artery aneurysms (ECAA are rare but may be accompanied with significant morbidity. Previous studies mostly focused on diagnostic imaging and treatment. In contrast, the pathophysiological mechanisms and natural course of ECAA are largely unknown. Understanding the pathophysiological background may add to prediction of risk for adverse outcome and need for surgical exclusion. The aim of this study was to investigate the histopathological characteristics of ECAA in patients who underwent complete surgical ECAA resection.From March 2004 till June 2013, 13 patients were treated with open ECAA repair. During surgery the aneurysm sac was resected and processed for standardized histological analysis. Sections were stained with routine hematoxylin and eosin and special stains to detect elastin, collagen, different types of inflammatory cells, vascular smooth muscle cells and endothelial cells.Histopathological characterization revealed two distinct categories: dissection (abrupt interruption of the media; n = 3 and degeneration (general loss of elastin fibers in the media; n = 10. In the degenerative samples the elastin fibers in the media were fragmented and were partly absent. Inflammatory cells were observed in the vessel wall of the aneurysms.Histological analysis in this small sample size revealed dissection and degeneration as the two distinct underlying mechanisms in ECAA formation.

  13. Operative management of penetrating carotid artery injuries.

    Science.gov (United States)

    Reva, V A; Pronchenko, A A; Samokhvalov, I M

    2011-07-01

    To analyse management and outcomes of carotid artery (CA) injuries. Retrospective study of the patients in the combat operations in Chechnya (1999-2002) and in peacetime (2003-2009). A total of 46 patients with missile (27) and stab (19) wounds, who had common and internal CA injury, underwent an open surgery. Temporary shunts (TSs) were placed in eight patients with more severe injuries. Retrospective analysis of patients' data. CA ligation and CA repair were performed in 9 and 37 patients, respectively. Of the nine patients with CA ligation, five developed neurologic deficit; the remaining four patients died (100% of poor outcomes). Of the 37 patients with blood flow restoration, nine patients died and neurologic deficit persisted in two patients (30% of poor outcomes) (p < 0.05). Among patients with TS, three patients died and two had stable neurologic deficit (63% of poor results). Of the patients without TS, 10 patients died and five had neurologic disorders (56% of poor outcomes) (p = 0.53). CA repair is the method of choice in CA injury. TS use does not result in a decreased mortality rate or neurologic deficit reduction in patients with severe injuries. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Risk modelling study for carotid endarterectomy.

    Science.gov (United States)

    Kuhan, G; Gardiner, E D; Abidia, A F; Chetter, I C; Renwick, P M; Johnson, B F; Wilkinson, A R; McCollum, P T

    2001-12-01

    The aims of this study were to identify factors that influence the risk of stroke or death following carotid endarterectomy (CEA) and to develop a model to aid in comparative audit of vascular surgeons and units. A series of 839 CEAs performed by four vascular surgeons between 1992 and 1999 was analysed. Multiple logistic regression analysis was used to model the effect of 15 possible risk factors on the 30-day risk of stroke or death. Outcome was compared for four surgeons and two units after adjustment for the significant risk factors. The overall 30-day stroke or death rate was 3.9 per cent (29 of 741). Heart disease, diabetes and stroke were significant risk factors. The 30-day predicted stroke or death rates increased with increasing risk scores. The observed 30-day stroke or death rate was 3.9 per cent for both vascular units and varied from 3.0 to 4.2 per cent for the four vascular surgeons. Differences in the outcomes between the surgeons and vascular units did not reach statistical significance after risk adjustment. Diabetes, heart disease and stroke are significant risk factors for stroke or death following CEA. The risk score model identified patients at higher risk and aided in comparative audit.

  15. Indirect carotid cavernous fistula mimicking ocular myasthenia.

    Science.gov (United States)

    Leishangthem, Lakshmi; Satti, Sudhakar Reddy

    2017-10-19

    71-year-old woman with progressive left-sided, monocular diplopia and ptosis. Her symptoms mimicked ocular myasthenia, but she had an indirect carotid cavernous fistula (CCF). She was diagnosed with monocular myasthenia gravis (negative acetylcholinesterase antibody) after a positive ice test and started on Mestinon and underwent a thymectomy complicated by a brachial plexus injury. Months later, she developed left-sided proptosis and ocular bruit. She was urgently referred to neuro-interventional surgery and was diagnosed with an indirect high-flow left CCF, which was treated with Onyx liquid and platinum coil embolisation. Mestinon was discontinued. Her ophthalmic symptoms resolved. However, she was left with a residual left arm and hand hemiparesis and dysmetria secondary to a brachial plexus injury. Indirect CCF usually can present with subtle and progressive symptoms leading to delayed diagnosis or misdiagnosis. It is important for ophthalmologists to consider this differential in a patient with progressive ocular symptoms. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Duplex ultrasound surveillance after carotid artery endarterectomy.

    Science.gov (United States)

    Al Shakarchi, Julien; Lowry, Danielle; Nath, Jay; Khawaja, Aurangzaib Z; Inston, Nicholas; Tiwari, Alok

    2016-06-01

    After carotid endarterectomy (CEA), patients have been regularly followed up by duplex ultrasound imaging. However, the evidence for long-term follow-up is not clear, especially if the results from an early duplex scan are normal. This study assessed and systematically reviewed the evidence base for long-term surveillance after CEA and a normal early scan. Electronic databases were searched for studies assessing duplex surveillance after CEA in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The primary outcome for this study was the incidence of restenosis after a normal early scan. The secondary outcome was the number of reinterventions after a normal early scan. The review included seven studies that reported 2317 procedures. Of those patients with a normal early scan, 2.8% (95% confidence interval, 0.7%-6%) developed a restenosis, and 0.4% (95% confidence interval, 0%-0.9%) underwent a reintervention for their restenosis during the follow-up period. This review confirms that routine postoperative duplex ultrasound surveillance after CEA is not necessary if the early duplex scan is normal. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  17. Stent impact on the geometry of the carotid bifurcation and the course of the internal carotid artery

    International Nuclear Information System (INIS)

    Berkefeld, J.; Zanella, F.E.; Rosendahl, H.; Theron, J.G.; Guimaraens, L.; Treggiari-Venzi, M.M.

    2002-01-01

    A measurement system is proposed to evaluate reconstructive effects of carotid stents on the geometry of the carotid bifurcation and the course of the internal carotid artery. To describe deviations of the stenotic internal carotid artery (ICA) from the extended axis of the common carotid artery (CCA) the CCA-ICA angle is measured between the CCA midaxis and the midaxis of the stenotic ICA segment. Maximal extensions of ICA tortuosities perpendicular to the course of the CCA axis are defined as ICA offset. The measurements were applied to DSA images of 224 carotid stenoses to evaluate variation and correlation between the two parameters. Comparative pre- and post-stent evaluation was performed in two series of 55 and 31 carotid stenoses treated with Wallstents and in a historic control group of 35 stenoses treated with Strecker stents. Straight course of the ICA was associated with low angle and low offset values, whereas tortuous course of the ICA showed larger angle and offset. A moderate linear correlation between the two parameters was found. Corresponding to a straightening of the stented segment, Wallstents reduced mean angle and offset values significantly. In five cases of the second series of Wallstents, transferrals of curves above the distal stent end associated with kinks were observed, and offset remained constant or increased. Strecker stent implantation caused no significant changes of bifurcational geometry. The proposed parameters corresponded to visual aspects of ICA tortuosity and detected reconstructive effects of self-expanding Wallstents on the ICA course. The measurement system may provide a basis for geometric evaluation of different stent types or implantation concepts with the aim: to optimize anatomic recanalization results in tortuous high angle-high offset bifurcations. (orig.)

  18. Contemporary carotid imaging: from degree of stenosis to plaque vulnerability.

    Science.gov (United States)

    Brinjikji, Waleed; Huston, John; Rabinstein, Alejandro A; Kim, Gyeong-Moon; Lerman, Amir; Lanzino, Giuseppe

    2016-01-01

    Carotid artery stenosis is a well-established risk factor of ischemic stroke, contributing to up to 10%-20% of strokes or transient ischemic attacks. Many clinical trials over the last 20 years have used measurements of carotid artery stenosis as a means to risk stratify patients. However, with improvements in vascular imaging techniques such as CT angiography and MR angiography, ultrasonography, and PET/CT, it is now possible to risk stratify patients, not just on the degree of carotid artery stenosis but also on how vulnerable the plaque is to rupture, resulting in ischemic stroke. These imaging techniques are ushering in an emerging paradigm shift that allows for risk stratifications based on the presence of imaging features such as intraplaque hemorrhage (IPH), plaque ulceration, plaque neovascularity, fibrous cap thickness, and presence of a lipid-rich necrotic core (LRNC). It is important for the neurosurgeon to be aware of these new imaging techniques that allow for improved patient risk stratification and outcomes. For example, a patient with a low-grade stenosis but an ulcerated plaque may benefit more from a revascularization procedure than a patient with a stable 70% asymptomatic stenosis with a thick fibrous cap. This review summarizes the current state-of-the-art advances in carotid plaque imaging. Currently, MRI is the gold standard in carotid plaque imaging, with its high resolution and high sensitivity for identifying IPH, ulceration, LRNC, and inflammation. However, MRI is limited due to time constraints. CT also allows for high-resolution imaging and can accurately detect ulceration and calcification, but cannot reliably differentiate LRNC from IPH. PET/CT is an effective technique to identify active inflammation within the plaque, but it does not allow for assessment of anatomy, ulceration, IPH, or LRNC. Ultrasonography, with the aid of contrast enhancement, is a cost-effective technique to assess plaque morphology and characteristics, but it is

  19. Selective occlusion of a carotid sinus cavernous fistula after transsphenoidal hypophysectomy

    International Nuclear Information System (INIS)

    Lins, E.; Dietrich, U.; Wappenschmidt, J.

    1987-01-01

    A case of carotid cavernous sinus fistula following transsphenoidal hypophysectomy is reported. A selective occlusion of the fistula with patency of the carotid artery was achieved by means of a detachable balloon catheter. (orig.) [de

  20. Association between plasma homocysteine concentrations and extracranial carotid stenosis

    International Nuclear Information System (INIS)

    Mousavi, Seyed Ali; Ghasemi, M.; Hoseini, T.

    2006-01-01

    Increasing epidemiologic data support a relationship between elevated plasma total homocysteine levels and an increased risk for vascular disease. Higher plasma total homocysteine (tHcy) levels have been associated with extracranial carotid atherosclerosis and cerebral infarction in whites. However, data regarding such associations are limited for Asians. This study examined the association between tHcy level and carotid stenosis in Iranian subjects. In this retrospective study, the subjects were 158 patients with ischemic stroke, including 105 with a normal tHcy level and 53 with a high tHcy level. We investigated the extracranial carotid arteries by ultrasonography and measured serum tHcy by ELISA method in these two groups. We found no meaningful association between a high tHcy level and carotid stenosis. The lack of any meaningful difference in carotid stenosis between patients with normal and elevated tHcy levels is probably due to the low frequency of extracranial diseases in the Asian population and to the nature of homocysteine atherosclerosis. (author)

  1. Intraoperative Hypoglossal Nerve Mapping During Carotid Endarterectomy: Technical Note.

    Science.gov (United States)

    Kojima, Atsuhiro; Saga, Isako; Ishikawa, Mami

    2018-05-01

    Hypoglossal nerve deficit is a possible complication caused by carotid endarterectomy (CEA). The accidental injury of the hypoglossal nerve during surgery is one of the major reasons for permanent hypoglossal nerve palsy. In this study, we investigated the usefulness of intraoperative mapping of the hypoglossal nerve to identify this nerve during CEA. Five consecutive patients who underwent CEA for the treatment of symptomatic or asymptomatic carotid artery stenosis were studied. A hand-held probe was used to detect the hypoglossal nerve in the operative field, and the tongue motor evoked potentials (MEPs) were recorded. The tongue MEPs were obtained in all the patients. The invisible hypoglossal nerve was successfully identified without any difficulty when the internal carotid artery was exposed. Intraoperative mapping was particularly useful for identifying the hypoglossal nerve when the hypoglossal nerve passed beneath the posterior belly of the digastric muscle. In 1 of 2 cases, MEP was also elicited when the ansa cervicalis was stimulated, although the resulting amplitude was much smaller than that obtained by direct stimulation of the hypoglossal nerve. Postoperatively, none of the patients presented with hypoglossal nerve palsy. Intraoperative hypoglossal nerve mapping enabled us to locate the invisible hypoglossal nerve during the exposure of the internal carotid artery accurately without retracting the posterior belly of the digastric muscle and other tissues in the vicinity of the internal carotid artery. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. The transradial approach for selective carotid and vertebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Radiology; Yokoyama, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Neurosurgery; Takayama, K.; Nakagawa, H.; Kichikawa, K. [Nara Medical Univ., Osaka (Japan). Dept. of Radiology

    2002-11-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications.

  3. The transradial approach for selective carotid and vertebral angiography

    International Nuclear Information System (INIS)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K.; Yokoyama, K.; Takayama, K.; Nakagawa, H.; Kichikawa, K.

    2002-01-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications

  4. Assessment of carotid plaque vulnerability using structural and geometrical determinants

    International Nuclear Information System (INIS)

    Li, Z.Y.; Tang, T.; U-King-Im, J.; Graves, M.; Gillard, J.H.; Sutcliffe, M.

    2008-01-01

    Because many acute cerebral ischemic events are caused by rupture of vulnerable carotid atheroma and subsequent thrombosis, the present study used both idealized and patient-specific carotid atheromatous plaque models to evaluate the effect of structural determinants on stress distributions within plaque. Using a finite element method, structural analysis was performed using models derived from in vivo high-resolution magnetic resonance imaging (MRI) of carotid atheroma in 40 non-consecutive patients (20 symptomatic, 20 asymptomatic). Plaque components were modeled as hyper-elastic materials. The effects of varying fibrous cap thickness, lipid core size and lumen curvature on plaque stress distributions were examined. Lumen curvature and fibrous cap thickness were found to be major determinants of plaque stress. The size of the lipid core did not alter plaque stress significantly when the fibrous cap was relatively thick. The correlation between plaque stress and lumen curvature was significant for both symptomatic (p=0.01; correlation coefficient: 0.689) and asymptomatic patients (p=0.01; correlation coefficient: 0.862). Lumen curvature in plaques of symptomatic patients was significantly larger than those of asymptomatic patients (1.50±1.0 mm -1 vs 1.25±0.75 mm -1 ; p=0.01). Specific plaque morphology (large lumen curvature and thin fibrous cap) is closely related to plaque vulnerability. Structural analysis using high-resolution MRI of carotid atheroma may help in detecting vulnerable atheromatous plaque and aid the risk stratification of patients with carotid disease. (author)

  5. Increased LDL susceptibility to oxidation accelerates future carotid artery atherosclerosis

    Directory of Open Access Journals (Sweden)

    Aoki Toshinari

    2012-01-01

    Full Text Available Abstract Background We analyzed the causal relationship between LDL susceptibility to oxidation and the development of new carotid artery atherosclerosis over a period of 5 years. We previously described the determinants related to a risk of cardiovascular changes determined in a Japanese population participating in the Niigata Study, which is an ongoing epidemiological investigation of the prevention of cardiovascular diseases. Methods We selected 394 individuals (169 males and 225 females who underwent a second carotid artery ultrasonographic examination in 2001 - 2002 for the present study. The susceptibility of LDL to oxidation was determined as the photometric absorbance and electrophoretic mobility of samples that had been collected in 1996 - 1997. The measurements were compared with ultrasonographic findings obtained in 2001 - 2002. Results The multivariate-adjusted model showed that age (odds ratio (OR, 1.034; 95% confidence interval (95%CI, 1.010 - 1.059, HbA1c (OR, 1.477; 95%CI, 0.980 - 2.225, and photometric O/N (OR, 2.012; 95%CI, 1.000 - 4.051 were significant variables that could independently predict the risk of new carotid artery atherosclerosis. Conclusion The susceptibility of LDL to oxidation was a significant parameter that could predict new carotid artery atherosclerosis over a 5-year period, and higher susceptibility was associated with a higher incidence of new carotid artery atherosclerosis.

  6. Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis

    International Nuclear Information System (INIS)

    Dorresteijn, Lucille; Vogels, Oscar; Leeuw, Frank-Erik de; Vos, Jan-Albert; Christiaans, Marleen H.; Ackerstaff, Rob; Kappelle, Arnoud C.

    2010-01-01

    Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.

  7. Triglyceride glucose index and common carotid wall shear stress.

    Science.gov (United States)

    Tripolino, Cesare; Irace, Concetta; Scavelli, Faustina B; de Franceschi, Maria S; Esposito, Teresa; Carallo, Claudio; Gnasso, Agostino

    2014-02-01

    Alterations in wall shear stress contribute to both clinical and subclinical atherosclerosis. Several conditions such as hypertension, diabetes, and obesity can impair shear stress, but the role of insulin resistance has never been investigated. The present study was designed to investigate whether insulin resistance assessed by TyG Index associates with wall shear stress in the common carotid artery. One hundred six individuals were enrolled. Blood pressure, lipids, glucose, and cigarette smoking were evaluated. TyG Index was calculated as log[fasting triglycerides × fasting glucose / 2]. Subjects underwent blood viscosity measurement and echo-Doppler evaluation of carotid arteries to calculate wall shear stress. The association between TyG Index and carotid wall shear stress was assessed by simple and multiple regression analyses. TyG Index was significantly and inversely associated with carotid wall shear stress both in simple (r = -0.44, P glucose greater than 100 mg/dL, and triglycerides greater than 150 mg/dL. The present findings suggest that increasing insulin resistance, as assessed by TyG Index, associates with atherosclerosis-prone shear stress reduction in the common carotid artery.

  8. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Fabrication of a vertical sidewall using double-sided anisotropic etching of 〈1 0 0〉 oriented silicon

    International Nuclear Information System (INIS)

    Kim, Hyun-Seok; Bang, Yong-Seung; Song, Eun-Seok; Kim, Yong-Kweon; Kim, Jung-Mu; Ji, Chang-Hyeon

    2012-01-01

    A double-sided wet etch process has been proposed to fabricate vertical structures in 〈1 0 0〉 oriented silicon substrate. Both sides of a {1 0 0} silicon wafer have been patterned identically along the 〈1 1 0〉 direction, and etched using potassium hydroxide (KOH) solution. By precisly controlling the etch time, using etch-timer structure and additive control, structures with smooth and vertical {1 1 0} sidewalls have been fabricated at the edges of a rectangular opening without undercut. Rectangular through-holes, bridges and cantilevers have been constructed using the proposed process. The measured average surface roughness of the vertical sidewall was 481 nm, which has been further reduced to 217 nm and 218 nm by postetching using a KOH–IPA and TMAH–Triton mixture, respectively. Slanted {4 1 1} planes exposed at the concave corners during the vertical etch process have been successfully removed or diminished by the postetching process. A bridge structure with a high aspect ratio of 39:1 has been fabricated, and cantilevers without undercutting were successfully constructed by applying the compensation technique. The proposed process can potentially be utilized in place of the deep reactive ion etching process for the fabrication of structures having vertical through-holes, such as through-silicon vias, high aspect ratio springs and filters for microfluidic applications. (paper)

  10. Effect of fluorocarbon self-assembled monolayer films on sidewall adhesion and friction of surface micromachines with impacting and sliding contact interfaces

    International Nuclear Information System (INIS)

    Xiang, H.; Komvopoulos, K.

    2013-01-01

    A self-assembled monolayer film consisting of fluoro-octyltrichlorosilane (FOTS) was vapor-phase deposited on Si(100) substrates and polycrystalline silicon (polysilicon) surface micromachines. The hydrophobic behavior and structural composition of the FOTS film deposited on Si(100) were investigated by goniometry and X-ray photoelectron spectroscopy, respectively. The effects of contact pressure, relative humidity, temperature, and impact/sliding cycles on the adhesive and friction behavior of uncoated and FOTS-coated polysilicon micromachines (referred to as the Si and FOTS/Si micromachines, respectively) were investigated under controlled loading and environmental conditions. FOTS/Si micromachines demonstrated much lower and stable adhesion than Si micromachines due to the highly hydrophobic and conformal FOTS film. Contrary to Si micromachines, sidewall adhesion of FOTS/Si micromachines demonstrated a weak dependence on relative humidity, temperature, and impact cycles. In addition, FOTS/Si micromachines showed low and stable adhesion and low static friction for significantly more sliding cycles than Si micromachines. The adhesive and static friction characteristics of Si and FOTS/Si micromachines are interpreted in the context of physicochemical surface changes, resulting in the increase of the real area of contact and a hydrophobic-to-hydrophilic transition of the surface chemical characteristics caused by nanoscale surface smoothening and the removal of the organic residue (Si micromachines) or the FOTS film (FOTS/Si micromachines) during repetitive impact and oscillatory sliding of the sidewall surfaces.

  11. The effect of sidewall roughness on line edge roughness in top-down scanning electron microscopy images

    Science.gov (United States)

    Verduin, T.; Lokhorst, S. R.; Kruit, P.; Hagen, C. W.

    2015-03-01

    We have investigated in a numerical study the determination of sidewall roughness (SWR) from top down scanning electron microscopy (SEM) images. In a typical metrology application, top-down SEM images are acquired in a (critical-dimension) SEM and the roughness is analyzed. However, the true size, shape and roughness characteristics of resist features are not fully investigated in the analysis of top-down SEM images. In reality, rough resist features are complex three-dimensional structures and the characterization naturally extends to the analysis of SWR. In this study we randomly generate images of rough lines and spaces, where the lines are made of PMMA on a silicon substrate. The lines that we study have a length of 2 µm, a width of 32nm and a height of 32 nm. The SWR is modeled by using the power spectral density (PSD) function of Palasantzas, which characterizes roughness by the standard deviation σ, correlation length ξ and roughness exponent α . The actual roughness is generated by application of the method of Thorsos in two dimensions. The images are constructed by using a home-built program for simulating electron-specimen interactions. The program that we have developed is optimized for complex arbitrary geometries and large number of incident low energy primary electrons by using multi-core CPUs and GPUs. The program uses the dielectric function model for inelastic scattering events and has an implementation specifically for low energy electrons. A satisfactory comparison is made between the secondary electron yields from the home-built program and another program found in literature. In order to reduce the risk of shrinkage, we use a beam energy of 300 eV and a spot size of 3 nm. Each pixel is exposed with 20 electrons on average (≍ 276 µC/cm2), following the Poisson distribution to account for illumination shot noise. We have assumed that the detection of electrons is perfect and does not introduce additional noise. We measure line edge

  12. Characterising human atherosclerotic carotid plaque tissue composition and morphology using combined spectroscopic and imaging modalities.

    Science.gov (United States)

    Barrett, Hilary E; Mulvihill, John J; Cunnane, Eoghan M; Walsh, Michael T

    2015-01-01

    Calcification is a marked pathological component in carotid artery plaque. Studies have suggested that calcification may induce regions of high stress concentrations therefore increasing the potential for rupture. However, the mechanical behaviour of the plaque under the influence of calcification is not fully understood. A method of accurately characterising the calcification coupled with the associated mechanical plaque properties is needed to better understand the impact of calcification on the mechanical behaviour of the plaque during minimally invasive treatments. This study proposes a comparison of biochemical and structural characterisation methods of the calcification in carotid plaque specimens to identify plaque mechanical behaviour. Biochemical analysis, by Fourier Transform Infrared (FTIR) spectroscopy, was used to identify the key components, including calcification, in each plaque sample. However, FTIR has a finite penetration depth which may limit the accuracy of the calcification measurement. Therefore, this FTIR analysis was coupled with the identification of the calcification inclusions located internally in the plaque specimen using micro x-ray computed tomography (μX-CT) which measures the calcification volume fraction (CVF) to total tissue content. The tissue characterisation processes were then applied to the mechanical material plaque properties acquired from experimental circumferential loading of human carotid plaque specimen for comparison of the methods. FTIR characterised the degree of plaque progression by identifying the functional groups associated with lipid, collagen and calcification in each specimen. This identified a negative relationship between stiffness and 'lipid to collagen' and 'calcification to collagen' ratios. However, μX-CT results suggest that CVF measurements relate to overall mechanical stiffness, while peak circumferential strength values may be dependent on specific calcification geometries. This study

  13. Perspective: carotid stenting and the history of disruptive technology in vascular surgery.

    Science.gov (United States)

    Veith, Frank J

    2008-06-01

    This article defines disruptive technology and discusses such technologies in Vascular Surgery. It considers the question: Is carotid artery stenting (CAS) a disruptive technology? Although CAS will impact positively on the treatment of carotid bifurcation disease, it will probably never displace carotid endarterectomy in the majority of patients. The precise role of CAS remains to be determined.

  14. Optimal Treatment of the ‘High-Risk’ Patient with Carotid Artery Stenosis

    NARCIS (Netherlands)

    Fokkema, T.M.

    2013-01-01

    Four landmark randomized trials have clearly validated the use of carotid endarterectomy (CEA) for the management of asymptomatic and symptomatic significant carotid artery stenosis. However, its risk-to-benefit ratio is variable for different patients. With the advent of carotid artery stenting

  15. Computed tomography of the carotid space and related cervical spaces. Part 1. Anatomy

    International Nuclear Information System (INIS)

    Silver, A.J.; Mawad, M.E.; Hilal, S.K.; Sane, P.; Ganti, S.R.

    1984-01-01

    The carotid space, parapharyngeal space, and paraspinal space are described. The carotid space is shown on computed tomography (CT) to be posterior to the parapharyngeal space and separated from it by the styloid apparatus. The paraspinal space is posterior to the carotid space and separated from it by the longus and anterior scalene muscles

  16. File list: NoD.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.05.AllAg.Carotid_Arteries hg19 No description Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.05.AllAg.Carotid_Arteries.bed ...

  17. File list: ALL.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.05.AllAg.Carotid_Arteries hg19 All antigens Cardiovascular Carotid Arteries... DRX021453,DRX021454,DRX021452 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.05.AllAg.Carotid_Arteries.bed ...

  18. MRI of the carotid artery at 7 Tesla: Quantitative comparison with 3 Tesla

    NARCIS (Netherlands)

    Koning, Wouter; De Rotte, Alexandra A J; Bluemink, Johanna J.; Van Der Velden, Tijl A.; Luijten, Peter R.; Klomp, DWJ; Zwanenburg, Jaco J M

    2015-01-01

    Purpose: To evaluate the 7 Tesla (T) MRI of the carotid arteries, as quantitatively compared with 3T. Materials and Methods: The 7T MRI of the carotid arteries was performed in six healthy subjects and in two patients with carotid stenosis. The healthy group was scanned at 3T and at 7T, using

  19. File list: Oth.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.20.AllAg.Carotid_Arteries hg19 TFs and others Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.20.AllAg.Carotid_Arteries.bed ...

  20. File list: Pol.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.CDV.10.AllAg.Carotid_Arteries hg19 RNA polymerase Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.CDV.10.AllAg.Carotid_Arteries.bed ...

  1. File list: DNS.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.05.AllAg.Carotid_Arteries hg19 DNase-seq Cardiovascular Carotid Arteries ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.05.AllAg.Carotid_Arteries.bed ...

  2. File list: ALL.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.10.AllAg.Carotid_Arteries hg19 All antigens Cardiovascular Carotid Arteries... DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.10.AllAg.Carotid_Arteries.bed ...

  3. File list: Oth.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.50.AllAg.Carotid_Arteries hg19 TFs and others Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.50.AllAg.Carotid_Arteries.bed ...

  4. File list: InP.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.10.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.10.AllAg.Carotid_Arteries.bed ...

  5. File list: InP.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.50.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.50.AllAg.Carotid_Arteries.bed ...

  6. File list: NoD.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.50.AllAg.Carotid_Arteries hg19 No description Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.50.AllAg.Carotid_Arteries.bed ...

  7. File list: InP.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.05.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021453,DRX021454,DRX021452 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.05.AllAg.Carotid_Arteries.bed ...

  8. File list: Pol.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.CDV.05.AllAg.Carotid_Arteries hg19 RNA polymerase Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.CDV.05.AllAg.Carotid_Arteries.bed ...

  9. File list: DNS.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.50.AllAg.Carotid_Arteries hg19 DNase-seq Cardiovascular Carotid Arteries ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.50.AllAg.Carotid_Arteries.bed ...

  10. File list: InP.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.CDV.20.AllAg.Carotid_Arteries hg19 Input control Cardiovascular Carotid Arterie...s DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.CDV.20.AllAg.Carotid_Arteries.bed ...

  11. File list: NoD.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.20.AllAg.Carotid_Arteries hg19 No description Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.20.AllAg.Carotid_Arteries.bed ...

  12. File list: ALL.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.50.AllAg.Carotid_Arteries hg19 All antigens Cardiovascular Carotid Arteries... DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.50.AllAg.Carotid_Arteries.bed ...

  13. File list: DNS.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.10.AllAg.Carotid_Arteries hg19 DNase-seq Cardiovascular Carotid Arteries ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.10.AllAg.Carotid_Arteries.bed ...

  14. File list: Oth.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.10.AllAg.Carotid_Arteries hg19 TFs and others Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.10.AllAg.Carotid_Arteries.bed ...

  15. File list: Pol.CDV.50.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.CDV.50.AllAg.Carotid_Arteries hg19 RNA polymerase Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.CDV.50.AllAg.Carotid_Arteries.bed ...

  16. File list: ALL.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.CDV.20.AllAg.Carotid_Arteries hg19 All antigens Cardiovascular Carotid Arteries... DRX021452,DRX021453,DRX021454 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.CDV.20.AllAg.Carotid_Arteries.bed ...

  17. File list: DNS.CDV.20.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.CDV.20.AllAg.Carotid_Arteries hg19 DNase-seq Cardiovascular Carotid Arteries ht...tp://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.CDV.20.AllAg.Carotid_Arteries.bed ...

  18. File list: NoD.CDV.10.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available NoD.CDV.10.AllAg.Carotid_Arteries hg19 No description Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/NoD.CDV.10.AllAg.Carotid_Arteries.bed ...

  19. File list: Oth.CDV.05.AllAg.Carotid_Arteries [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CDV.05.AllAg.Carotid_Arteries hg19 TFs and others Cardiovascular Carotid Arteri...es http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Oth.CDV.05.AllAg.Carotid_Arteries.bed ...

  20. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  1. Feasibility of simultaneous PET/MR of the carotid artery

    DEFF Research Database (Denmark)

    Ripa, Rasmus S; Knudsen, Andreas; Hag, Anne Mette F

    2013-01-01

    The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of (18)F-FDG. PET/MR was performed a median of 131......) indicating that the luminal (18)F-FDG content had minimal influence on the values. The study shows for the first time that simultaneous PET/MR of the carotid arteries is feasible in patients with increased risk of atherosclerosis. Quantification of (18)F-FDG uptake correlated well between PET/MR and PET...

  2. Gene expression and 18FDG uptake in atherosclerotic carotid plaques

    DEFF Research Database (Denmark)

    Pedersen, Sune Folke; Graebe, Martin; Fisker Hag, Anne Mette

    2010-01-01

    ) and an additional ipsilateral internal carotid artery stenosis of greater than 60% were recruited. FDG uptake in the carotids was determined by PET/computed tomography and expressed as mean and maximal standardized uptake values (SUVmean and SUVmax). The atherosclerotic plaques were subsequently recovered...... by carotid endarterectomy. The gene expression of markers of vulnerability - CD68, IL-18, matrix metalloproteinase 9, cathepsin K, GLUT-1, and hexokinase type II (HK2) - were measured in plaques by quantitative PCR. RESULTS: In a multivariate linear regression model, GLUT-1, CD68, cathepsin K, and HK2 gene...... expression remained in the final model as predictive variables of FDG accumulation calculated as SUVmean (R=0.26, PK, and HK2 gene expression as independent predictive variables of FDG accumulation calculated...

  3. Pain as the only manifestation of internal carotid artery dissection.

    Science.gov (United States)

    Biousse, V; Woimant, F; Amarenco, P; Touboul, P J; Bousser, M G

    1992-10-01

    Internal carotid artery dissection is a major cause of ischemic stroke in the young. Pain is the leading symptom and is associated with other focal signs such as Horner's syndrome and painful tinnitus or with signs of cerebral or retinal ischemia. We report two patients with angiographically confirmed extracranial internal carotid artery dissection presenting with cephalic pain as the only manifestation. The first patient had a diffuse headache and a latero-cervical pain lasting for 12 days, reminiscent of carotidynia. The second patient experienced an exploding headache suggestive of subarachnoid hemorrhage, which was ruled out by computed tomography of the head and cerebrospinal fluid study. These patients demonstrate that recognition of carotid artery dissection as a cause of carotidynia and headache suggestive of subarachnoid hemorrhage may permit an earlier diagnosis and possibly the prevention of a stroke through the use of anticoagulation.

  4. Associations between bicycling and carotid arterial stiffness in adolescents

    DEFF Research Database (Denmark)

    Ried-Larsen, M; Grøntved, A; Østergaard, Lars

    2015-01-01

    Youth Heart Study. Total frequency of bicycle usage was assessed by self-report, and carotid arterial stiffness was assessed using B-mode ultrasound. After adjusting for pubertal status, body height, and objectively measured physical activity and other personal lifestyle and demographic factors, boys......The aim of the study was to investigate the associations between bicycling and carotid arterial stiffness, independent of objectively measured moderate-and-vigorous physical activity. This cross-sectional study included 375 adolescents (age 15.7 ± 0.4 years) from the Danish site of the European...... using their bicycle every day of the week displayed a higher carotid arterial compliance {standard beta 0.47 [95% confidence interval (CI) 0.07-0.87]} and distension [standard beta 0.38 (95% CI -0.04 to 0.81)]. Boys using their bicycle every day of the week furthermore displayed a lower Young's elastic...

  5. Radiation-induced bilateral common carotid artery stenosis

    International Nuclear Information System (INIS)

    Kobayashi, Nobuaki; Nakagawa, Yoku; Tashiro, Kunio; Abe, Hiroshi

    1986-01-01

    A case of radiation-induced bilateral common carotid artery stenosis is reported. This 60 years old housewife was hospitalized in 1982 because of sudden onset of mild left hemiparesis. Twenty-five years ago, she underwent radiation therapy of approximately 5,000 rads to the anterior cervical region because of thyroid cancer. Angiograms in 1982 revealed bilateral common carotid artery stenosis, especially in the right common carotid artery, the legion of which were included within the field of radiation performed in 1952. Right thromboendarterectomy was performed in 1983. At operation, slight periarterial fibrosis with calcified arteriosclerotic change was found, and dissection between the thickened intima and the media was not so difficult. Histological change of resected thromboendarterium was similar to the one observed in the pure arteriosclerotic disease. (author)

  6. Primary mycotic aneurysm of the common carotid artery: Case report

    International Nuclear Information System (INIS)

    Lukasiewicz, A.; Molski, S.; Jundzill, W.; Meder, G.; Lasek, W.

    2006-01-01

    Aneurysms of the common carotid artery are relatively rare. Mycotic aneurysms in such location occur even less frequently. Causative factors can be sepsis, recent surgery, or dental procedures. Immunosuppression may also be a burdening factor. The authors present the case of a 70-year-old male patient with primary mycotic carotid artery aneurysm. The patient was diagnosed with ultrasound and multidetector spiral computed tomography and treated operatively with a PTFE prosthesis. Culture-appropriate antibiotic therapy was administered during the perioperative period. The rarity of extracranial carotid artery aneurysms might cause diagnostic and treatment difficulties. Open surgery is the recommended method, although the endovascular approach is gaining more acceptance. The choice of treatment modality might be facilitated by a detailed morphologic description of the aneurysm and its surroundings. Available methods of imaging are described. (author)

  7. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  8. Quality of life after carotid endarterectomy

    Directory of Open Access Journals (Sweden)

    Barros Henrique

    2008-11-01

    Full Text Available Abstract Background Most studies documenting beneficial outcomes after carotid endarterectomy (CE are limited to mortality and morbidity rates, costs, and length of hospital stay (LOS. Few have examined the dependency of patients and how they perceive their own health changes after surgery. The aim of the present study was to evaluate quality of life and independence in activities of daily living (ADL and to study its determinants. Methods Sixty-three patients admitted in the Post Anaesthesia Care Unit (PACU after CE were eligible for this 14-month follow-up study. Patients were contacted 6 months after discharge to complete a Short Form-36 questionnaire (SF-36 and to have their dependency in ADL evaluated. Results Among 59 hospital survivors at 6 months follow-up, 43 completed the questionnaires. Sixty-three percent reported that their general level of health was better on the day they answered the questionnaire than 12 months earlier. Patients had worse SF-36 scores for all domains except bodily pain than a general urban population, and comparison with a group of patients 6 months after surgical ICU discharge showed no differences. Six months after PACU discharge, the Lawton Instrumental Activities of ADL Scale and the Katz Index of ADL demonstrated higher dependency scores (5.9 ± 2.2 versus 4.3 ± 2.4 and 0.3 ± 0.8 versus 0.6 ± 0.9, p Conclusion Patients undergoing CE have improved self-perception of quality of life despite being more dependent. Almost all their scores are worse than those in an urban population. We could identify no predictors of greater dependency in ADL tasks six months after PACU discharge.

  9. Serum elastase activity, serum elastase inhibitors, and occurrence of carotid atherosclerotic plaques: the Etude sur le Vieillissement Artériel (EVA) study.

    Science.gov (United States)

    Zureik, Mahmoud; Robert, Ladislas; Courbon, Dominique; Touboul, Pierre-Jean; Bizbiz, Latifa; Ducimetière, Pierre

    2002-06-04

    In the last decades, interest has increased in the potential deleterious atherogenic effects of some cellular elastase activities. The results of experimental and clinical investigations were inconsistent. In this report, we assessed the associations of serum elastase activity and serum elastase inhibitors with carotid plaque occurrence during the 4-year follow-up in a population of 859 subjects free of coronary heart disease and stroke (age, 59 to 71 years). Serum elastase activity and serum elastase inhibitors were measured at baseline examination. Carotid B-mode ultrasound examination was performed at baseline and 2 years and 4 years later. The occurrence of carotid plaques in subjects with the lowest serum elastase activity values (quartile 1), in those with the intermediate values (quartiles 2 to 3), and in those with the highest values (quartile 4) was, respectively, 24.6%, 18.9%, and 12.2% (P<0.001 for trend). The multivariate odds ratios of carotid plaque occurrence associated with the three groups (adjusted for major known cardiovascular risk factors) were, respectively, 1.00, 0.67 (CI, 0.44 to 1.02; P<0.06), and 0.40 (CI, 0.23 to 0.70, P<0.001). For serum elastase inhibitors, the occurrence of carotid plaques in quartile 1 (lowest values), quartiles 2 to 3, and quartile 4 (highest values) was, respectively, 11.7%, 18.8%, and 25.2% (P for trend<0.001). The corresponding multivariate adjusted odds ratios were 1.00, 1.98 (CI, 1.19 to 3.31, P<0.01), and 3.18 (CI, 1.80 to 5.60, P<0.001). Low values of serum elastase activity and high values of serum elastase inhibitors were strongly and independently associated with increased 4-year carotid plaque occurrence. Further studies are necessary to elucidate the nature of the associations between elastase parameters and atherosclerosis.

  10. Arterial function of carotid and brachial arteries in postmenopausal vegetarians

    Directory of Open Access Journals (Sweden)

    Su T

    2011-08-01

    Full Text Available Ta-Chen Su1, Pao-Ling Torng2, Jiann-Shing Jeng3, Ming-Fong Chen1, Chiau-Suong Liau1,41Division of Cardiology, Department of Internal Medicine, 2Department of Obstetrics and Gynecology, 3Department of Neurology, National Taiwan University Hospital, National Taiwan University College of Medicine, 4Cardiovascular Center, Taipei Buddist Tzu-Chi Hospital, Hsin-Dian, Taipei, TaiwanBackground: Vegetarianism is associated with a lower risk of cardiovascular disease. However, studies of arterial function in vegetarians are limited.Methods: This study investigated arterial function in vegetarianism by comparing 49 healthy postmenopausal vegetarians with 41 age-matched omnivores. The arterial function of the common carotid artery was assessed by carotid duplex, while the pulse dynamics method was used to measure brachial artery distensibility (BAD, compliance (BAC, and resistance (BAR. Fasting blood levels of glucose, lipids, lipoprotein (a, high-sensitivity C-reactive protein, homocysteine, and vitamin B12 were also measured.Results: Vegetarians had significantly lower serum cholesterol, high-density and low-density lipoprotein, and glucose compared with omnivores. They also had lower vitamin B12 but higher homocysteine levels. Serum levels of lipoprotein (a and high-sensitivity C-reactive protein were no different between the two groups. There were no significant differences in carotid beta stiffness index, BAC, and BAD between the two groups even after adjustment for associated covariates. However, BAR was significantly lower in vegetarians than in omnivores. Multiple linear regression analysis revealed that age and pulse pressure were two important determinants of carotid beta stiffness index and BAD. Vegetarianism is not associated with better arterial elasticity.Conclusion: Apparently healthy postmenopausal vegetarians are not significantly better in terms of carotid beta stiffness index, BAC, and BAD, but have significantly decreased BAR than

  11. Homocystein and carotid atherosclerosis in chronic renal failure.

    Science.gov (United States)

    Lubomirova, M; Tzoncheva, A; Petrova, J; Kiperova, B

    2007-10-01

    Since total homocysteine (Hcy) is markedly elevated in patients with chronic renal failure (CRF), it has been presented as potential factor contributing to the high risk of cardiovascular disease (CVD) in CRF. The aim of the study was to examine the significance of elevated Hcy and other cardiovascular risk factors for carotid atherosclerosis in patients with CRF. Fifty six patients 16-M, 40-F, average age 58+/-14.55, creatinine clearance 39.19+/-10.11 ml/min were examined. In addition, 20 control healthy subjects were examined. The association of Hcy levels and classic risk factors for atherosclerosis with common carotid intima-media thickness (IMT) was examined. B-mode ultrasound measurement of carotid IMT was performed in 56 hypertensive pts with CRF (glomerular filtration rate>20 ml/min and 0.05). Significant predictors for IMT were age (r=0.358, p<0.04), duration of hypertension (r=0.395, p=0.023), diabetes duration (r=0.343, p<0.02), as well as duration of CRF (r=0.324, p<0.006). There was a negative correlation between IMT and glomerular filtration rate assessed by creatinine clearance (r=-0.303, p<0.003). Renal function, described by creatinine clearance was the strongest determinant for Hcy levels (r=-0.332, p<0.008). Increased IMT was estimated in pts with CRF compared to healthy controls (0.74+/-0.10 vs 0.59+/-0.10, p<0.001). We found association between Hcy and carotid IMT ( r=0.344, p<0.015). No consistent association was found between IMT and other specific for CRF cardiovascular risk factors. The study suggests that patients with mild renal failure have increased IMT of the common carotid artery and that elevated plasma Hcy level in CRF is associated with carotid intima- media thickening.

  12. Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model

    Science.gov (United States)

    Yang, Xin; Jin, Jiaoying; Xu, Mengling; Wu, Huihui; He, Wanji; Yuchi, Ming; Ding, Mingyue

    2013-01-01

    Carotid atherosclerosis is a major reason of stroke, a leading cause of death and disability. In this paper, a segmentation method based on Active Shape Model (ASM) is developed and evaluated to outline common carotid artery (CCA) for carotid atherosclerosis computer-aided evaluation and diagnosis. The proposed method is used to segment both media-adventitia-boundary (MAB) and lumen-intima-boundary (LIB) on transverse views slices from three-dimensional ultrasound (3D US) images. The data set consists of sixty-eight, 17 × 2 × 2, 3D US volume data acquired from the left and right carotid arteries of seventeen patients (eight treated with 80 mg atorvastatin and nine with placebo), who had carotid stenosis of 60% or more, at baseline and after three months of treatment. Manually outlined boundaries by expert are adopted as the ground truth for evaluation. For the MAB and LIB segmentations, respectively, the algorithm yielded Dice Similarity Coefficient (DSC) of 94.4% ± 3.2% and 92.8% ± 3.3%, mean absolute distances (MAD) of 0.26 ± 0.18 mm and 0.33 ± 0.21 mm, and maximum absolute distances (MAXD) of 0.75 ± 0.46 mm and 0.84 ± 0.39 mm. It took 4.3 ± 0.5 mins to segment single 3D US images, while it took 11.7 ± 1.2 mins for manual segmentation. The method would promote the translation of carotid 3D US to clinical care for the monitoring of the atherosclerotic disease progression and regression. PMID:23533535

  13. Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model

    Directory of Open Access Journals (Sweden)

    Xin Yang

    2013-01-01

    Full Text Available Carotid atherosclerosis is a major reason of stroke, a leading cause of death and disability. In this paper, a segmentation method based on Active Shape Model (ASM is developed and evaluated to outline common carotid artery (CCA for carotid atherosclerosis computer-aided evaluation and diagnosis. The proposed method is used to segment both media-adventitia-boundary (MAB and lumen-intima-boundary (LIB on transverse views slices from three-dimensional ultrasound (3D US images. The data set consists of sixty-eight, 17 × 2 × 2, 3D US volume data acquired from the left and right carotid arteries of seventeen patients (eight treated with 80 mg atorvastatin and nine with placebo, who had carotid stenosis of 60% or more, at baseline and after three months of treatment. Manually outlined boundaries by expert are adopted as the ground truth for evaluation. For the MAB and LIB segmentations, respectively, the algorithm yielded Dice Similarity Coefficient (DSC of 94.4% ± 3.2% and 92.8% ± 3.3%, mean absolute distances (MAD of 0.26 ± 0.18 mm and 0.33 ± 0.21 mm, and maximum absolute distances (MAXD of 0.75 ± 0.46 mm and 0.84 ± 0.39 mm. It took 4.3 ± 0.5 mins to segment single 3D US images, while it took 11.7 ± 1.2 mins for manual segmentation. The method would promote the translation of carotid 3D US to clinical care for the monitoring of the atherosclerotic disease progression and regression.

  14. [Current guidelines on carotid artery stenting. Critical evaluation].

    Science.gov (United States)

    Hein-Rothweiler, R; Mudra, H

    2013-11-01

    Scientific data underlying current guidelines on treatment of carotid artery stenosis is subject to interdisciplinary discussion. In particular selective weighting of the randomized European studies leads to conflicting levels of recommendation and levels of evidence, especially when directly comparing guidelines under surgical versus endovascular guidance. Surgical guidelines recommend a limitation of carotid artery stenting (CAS) to symptomatic patients with specific surgical/anatomical disadvantages and/or severe comorbidities. The European Society of Cardiology (ESC) guidelines recommend the use of CAS only in patients at increased surgical risk but at the same time requires morbidity and mortality rates comparable to those of surgical interventions. Even one step further, the American guidelines and specifically the associated comments of the German Society of Cardiology on the above mentioned ESC guidelines put CAS and carotid endarterectomy (CEA) on a par in terms of treatment alternatives, presupposing analogous CEA complication rates. Differential interpretation of the so far inadequate data is a common issue of current evidence-based medicine. The difficulty in conceptualization of new studies concerning the therapy of carotid stenosis lies in the funding these large projects and also on the high patient number required to achieve adequate statistical power. Furthermore, during the estimated long study period substantial changes of current techniques and devices can be anticipated which might render the study results in part outdated by the time of publication. However, as long as no new randomized study results comparing medical, surgical and interventional treatment of carotid stenosis are available, the question on the optimal therapy for patients with carotid artery disease remains unanswered.

  15. Case of radiation induced aneurysm of extracranial carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Tashiro, Takashi; Ikota, Toshio; Yamashita, Kousuke; Kodama, Takao

    1988-08-01

    An unusual case of post-irradiation aneurysm of extracranial internal carotid artery is presented. A 70-year-old man, complaining of left cervical throbbing mass with focal pain, was admitted on February 8, 1985. It was noted, from his past history, that he had had surgery of the removal of cervical lymphnodes and that unknown dosage of irradiation had been added to the cervical region 30 years before. Left carotid angiography (on admission) demonstrated a giant aneurysm in the cervical portion of internal carotid artery. Right carotid angiography with compression of left carotid artery revealed good cross filling through anterior communicating artery. Computed tomography with contrast media showed a ring like enhanced mass, which was thought to suggest that a large part of the aneurysm was filled with intraluminal thrombosis. During 30 days of evaluation, the aneurysm grew larger and his cervical pain became untolerable. Operation, the resection of the aneurysm and the reconstruction (of circulation) with vein graft, was challenged on March 12. It was so difficult with meticulous work that the ligation of left common carotid artery was performed after all. Seven days after the operation, he suffered from the gastrointestinal bleeding, which was enough to lead him to hypovolemic shock. Thereafter, right hemiparesis and aphasia were brought about. Two months later, he died of pneumonia. On histological examination, it was demonstrated that the aneurysm communicated with the necrotic tissue and that the normal structure of the blood vessel was not observed in the aneurysmal wall and consisted of the collagenous fiber and granulated tissue. The aneurysm was interpreted as a false one.

  16. A case of radiation induced aneurysm of extracranial carotid artery

    International Nuclear Information System (INIS)

    Tashiro, Takashi; Ikota, Toshio; Yamashita, Kousuke; Kodama, Takao

    1988-01-01

    An unusual case of post-irradiation aneurysm of extracranial internal carotid artery is presented. A 70-year-old man, complaining of left cervical throbbing mass with focal pain, was admitted on February 8, 1985. It was noted, from his past history, that he had had surgery of the removal of cervical lymphnodes and that unknown dosage of irradiation had been added to the cervical region 30 years before. Left carotid angiography (on admission) demonstrated a giant aneurysm in the cervical portion of internal carotid artery. Right carotid angiography with compression of left carotid artery revealed good cross filling through anterior communicating artery. Computed tomography with contrast media showed a ring like enhanced mass, which was thought to suggest that a large part of the aneurysm was filled with intraluminal thrombosis. During 30 days of evaluation, the aneurysm grew larger and his cervical pain became untolerable. Operation, the resection of the aneurysm and the reconstruction (of circulation) with vein graft, was challenged on March 12. It was so difficult with meticulous work that the ligation of left common carotid artery was performed after all. Seven days after the operation, he suffered from the gastrointestinal bleeding, which was enough to lead him to hypovolemic shock. Thereafter, right hemiparesis and aphasia were brought about. Two months later, he died of pneumonia. On histological examination, it was demonstrated that the aneurysm communicated with the necrotic tissue and that the normal structure of the blood vessel was not observed in the aneurysmal wall and consisted of the collagenous fiber and granulated tissue. The aneurysm was interpreted as a false one. (author)

  17. Acute hemifacial ischemia as a late complication of carotid stenting

    Directory of Open Access Journals (Sweden)

    Maurizio Domanin, MD

    2017-06-01

    Full Text Available Concerns about carotid artery stenting (CAS center primarily on procedural complications like acute occlusion, stroke, and long-term intrastent restenosis. External carotid artery (ECA thrombosis is observed during CAS follow-up, but it often remains asymptomatic or, at worst, results in jaw claudication. We report here a case of late occlusion of the ECA after CAS with symptoms of acute homolateral facial ischemia as well as pain, cyanosis, tongue numbness, and skin coldness. The patient was submitted to local thrombolysis and balloon angioplasty with regression of symptoms after recanalization. With this report, we add a caveat about blockage of the ECA ostium during CAS.

  18. Neuroradiological diagnosis and interventional therapy of carotid cavernous fistulas

    International Nuclear Information System (INIS)

    Struffert, T.; Engelhorn, T.; Doelken, M.; Doerfler, A.; Holbach, L.

    2008-01-01

    Carotid cavernous fistulas are pathologic connections between the internal and/or external carotid artery and the cavernous sinus. According to Barrow one can distinguish between direct (high flow) and indirect (low flow) fistulas, whereby direct fistulas are often traumatic while indirect fistulas more frequently occur spontaneously in postmenopausal women. Diagnosis can easily be established using MRI and angiography, which allow exact visualization of the anatomy of fistulas to plan the interventional neurological therapy that in recent years has replaced surgical therapy. This article provides an overview on imaging findings, diagnosis using MRI and angiography as well as interventional treatment strategies. (orig.) [de

  19. Aberrant internal carotid artery presenting as a retrotympanic vascular mass

    International Nuclear Information System (INIS)

    Nicolay, Simon; De Foer, Bert; Bernaerts, Anja; Van Dinther, Joost; Parizel, Paul M

    2014-01-01

    We report a case of a young woman with an aberrant right internal carotid artery (ICA) presenting as a retrotympanic reddish mass. This variant of the ICA represents the collateral pathway that is formed as a result of an embryological agenesis of the cervical segment of the ICA. The embryonic inferior tympanic artery is recruited to bypass the absent carotid segment. This hypertrophied vessel may be seen otoscopically and wrongfully considered to be a vascular middle ear tumor. Informing the otorhinolaryngologist of this important vascular variant not only obviates biopsy but also helps in careful preoperative planning of eventual middle ear procedures

  20. A suggested training programme for carotid artery stenting (CAS)

    International Nuclear Information System (INIS)

    Gaines, Peter; Nicholson, Tony

    2006-01-01

    Carotid artery stenting as an alternative to traditional carotid endartrectomy is becoming increasingly important in the treatment of transient ischemic attack and stroke. Physicians from several different medical disciplines are interested in treating appropriate patients by this method. Patients are entitled to know what training and experience the surgeon or clinician has before giving consent. This should involve endovascular experience in all systems and experience and knowledge of cerebral angiography and intervention. A multidisciplinary approach and reporting of adverse events is vital for patient safety

  1. Computed tomography scan based prediction of the vulnerable carotid plaque

    DEFF Research Database (Denmark)

    Diab, Hadi Mahmoud Haider; Rasmussen, Lars Melholt; Duvnjak, Stevo

    2017-01-01

    BACKGROUND: Primary to validate a commercial semi-automated computed tomography angiography (CTA) -software for vulnerable plaque detection compared to histology of carotid endarterectomy (CEA) specimens and secondary validating calcifications scores by in vivo CTA with ex vivo non......-contrast enhanced computed tomography (NCCT). METHODS: From January 2014 to October 2016 53 patients were included retrospectively, using a cross-sectional design. All patients underwent both CTA and CEA. Sixteen patients had their CEA specimen NCCT scanned. The semi-automated CTA software analyzed carotid stenosis...

  2. Self expandable polytetrafluoroethylene stent for carotid blowout syndrome.

    Science.gov (United States)

    Tatar, E C; Yildirim, U M; Dündar, Y; Ozdek, A; Işik, E; Korkmaz, H

    2012-01-01

    Carotid blowout syndrome (CBS) is an emergency complication in patients undergoing treatment for head and neck cancers. The classical management of CBS is the ligation of the common carotid artery, because suturing is not be possible due to infection and necrosis of the field. In this case report, we present a patient with CBS, in whom we applied a self-expandable polytetrafluoroethylene (PTFE) stent and observed no morbidity. Endovascular stent is a life-saving technique with minimum morbidity that preserves blood flow to the brain. We believe that this method is preferable to ligation of the artery in CBS.

  3. Contemporary medical therapies of atherosclerotic carotid artery disease.

    Science.gov (United States)

    Cheng, Suk F; Brown, Martin M

    2017-03-01

    Contemporary medical therapy consists of identification and treatment of all patient-modifiable vascular risk factors. Specific atherosclerotic disease therapies are designed to reduce the risk of thrombosis, and the disease progression in order to reduce the risk of future cardiovascular events. Contemporary medical management emphasizes the need to support the patient in achieving lifestyle modifications and to adjust medication to achieve individualized target values for specific quantifiable risk factors. Antiplatelet therapy in the form of aspirin or clopidogrel is routinely used for the prevention of ischemic stroke in patients who have had a transient ischemic attack or stroke. There is evidence from a recent trial that the use of combination antiplatelet therapy with aspirin and clopidogrel started within 24 hours of minor stroke or transient ischemic attack reduces the risk of recurrent stroke compared to the use of aspirin alone, and therefore we use aspirin plus clopidogrel in recently symptomatic patients with carotid stenosis pending carotid revascularization. Anticoagulation with heparins or vitamin K antagonist is not recommended except in patients at risk for cardio-embolic events. Lowering blood pressure to target levels has been shown to slow down the progression of carotid artery stenosis and reduces the intima-media thickness of the carotid plaque, while lowering lipid levels with statins has become an essential element in the medical therapy of carotid artery stenosis. Diabetes management should be optimized. Lifestyle choices, including tobacco smoking, physical inactivity, unhealthy diet, obesity, and excessive alcohol intake, are all important modifiable vascular risk factors. The combination of dietary modification, physical exercise, and use of aspirin, a statin, and an antihypertensive agent can be expected to give a cumulative relative stroke risk reduction of 80%. The evidence suggests that intensive medical therapy is so effective that

  4. The evidence for medicine versus surgery for carotid stenosis

    International Nuclear Information System (INIS)

    Ederle, Joerg; Brown, Martin M.

    2006-01-01

    Atherosclerotic stenosis of the internal carotid artery is an important cause of stroke. Several large randomised trials have compared best medical management with carotid endarterectomy and provide a strong evidence base for advising and selecting patients for carotid surgery. Best medical management of carotid stenosis includes lowering of blood pressure, treatment with statins and antiplatelet therapy in symptomatic patients. Combined analysis of the symptomatic carotid surgery trials, together with observational data, has shown that patients with recently symptomatic severe carotid stenosis have a very high risk of recurrent stroke in the first few days and weeks after symptoms. Carotid endarterectomy has a risk of causing stroke or death at the time of surgery in symptomatic patients of around 5-7%, but in patients with recently symptomatic stenosis of more than 70%, the benefits of endarterectomy outweigh the risks. In patients with moderate stenosis of between 50 and 69%, the benefits may justify surgery in patients with very recent symptoms, and in patients older than 75 years within a few months of symptoms. Patients with less than 50% stenosis do not benefit from surgery. In asymptomatic patients, or those whose symptoms occurred more than 6 months ago, the benefits of surgery are considerably less. Patients with asymptomatic stenosis treated medically only have a small risk of future stroke when treated medically of about 2% per annum. If carotid endarterectomy can be performed safely with a perioperative stroke and death rate of no more than 3%, then the randomised trials showed a significant benefit of surgery over 5 years follow-up, with an overall reduction in the risk of stroke from about 11% over 5 years down to 6%. However, of 100 patients operated, only 5 will benefit from avoiding a stroke over 5 years. The majority of neurologists have concluded that this does not justify a policy of routine screening and endarterectomy for asymptomatic

  5. [An automatic system controlled by microcontroller for carotid sinus perfusion].

    Science.gov (United States)

    Yi, X L; Wang, M Y; Fan, Z Z; He, R R

    2001-08-01

    To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.

  6. Effect of white-matter lesions on the risk of periprocedural stroke after carotid artery stenting versus endarterectomy in the International Carotid Stenting Study (ICSS): a prespecified analysis of data from a randomised trial

    NARCIS (Netherlands)

    Ederle, J.; Davagnanam, I.; Worp, H.B. van der; Venables, G.S.; Lyrer, P.A.; Featherstone, R.L.; Brown, M.M.; Jager, H.R.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2013-01-01

    BACKGROUND: Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid

  7. Novel flow quantification of the carotid bulb and the common carotid artery with vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Haugaard, Per

    2014-01-01

    technique transverse oscillation the blood velocities of both the axial and the transverse directions are obtained and the complexity of blood flow can be visualized. The aim of the study was to determine the technical performance and interpretation of vector concentration as a tool for estimation of flow...... (US) using a commercial vector flow ultrasound scanner (ProFocus, BK Medical, Denmark) with a linear 5 MHz transducer transverse oscillation vector flow software. CCA and CB areas were marked in one cardiac cycle from each volunteer. The complex flow was assessed by medical expert evaluation...... and by vector concentration calculation. A vortex with complex flow was found in all carotid bulbs, whereas the CCA had mainly laminar flow. The medical experts evaluated the flow to be mainly laminar in the CCA (0.82 +/- 0.14) and mainly complex (0.23 +/- 0.22) in the CB. Likewise, the estimated vector...

  8. Polyunsaturated fats, carbohydrates and carotid disease: The Atherosclerosis Risk in Communities (ARIC) Carotid MRI study.

    Science.gov (United States)

    Dearborn, Jennifer L; Qiao, Ye; Guallar, Eliseo; Steffen, Lyn M; Gottesman, Rebecca F; Zhang, Yiyi; Wasserman, Bruce A

    2016-08-01

    Carbohydrates and fat intake have both been linked to development of atherosclerosis. We examined associations between glycemic index (GI) and fat intake with carotid atherosclerosis. The Atherosclerosis Risk in Communities (ARIC) cohort enrolled participants during the period 1987-1989 and the Carotid MRI sub-study occurred between 2004 and 2006 (1672 participants attending both visits). Measures of carbohydrate quality (usual GI), fat intake (total, polyunsaturated and saturated) and overall dietary quality index (DASH Diet Score) were derived from a 66-item food frequency questionnaire administered at baseline. Trained readers measured lipid core presence and maximum wall thickness. Using multivariate logistic regression, we determined the odds of lipid core presence by quintile (Q) of energy-adjusted dietary components. Restricted cubic spline models were used to examine non-linear associations between dietary components and maximum wall thickness. Mean daily polyunsaturated fat intake was 5 g (SD 1.4). GI and polyunsaturated fat intake had a nonlinear relationship with maximum wall thickness. Low (1-4 g) and high (6-12 g) polyunsaturated fat intake were associated with a statistically significant decreased odds of lipid core presence compared to intake in a majority of participants (OR Q5 vs. Q2-4: 0.64, 95% CI 0.42 to 0.98; OR Q1 vs. Q2-4: 0.64, 95% CI 0.42, 0.96), however, the association with lipid core was attenuated by adjustment for maximum wall thickness, hypertension, hyperlipidemia, and diabetes. GI and polyunsaturated fat intake were not associated with high-risk plaque features, such as lipid core presence, independent of traditional vascular risk factors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. The changes of individual carotid artery wall layer by aging and carotid intima-media thickness value for high risk.

    Science.gov (United States)

    Bae, Jang-Ho; Kim, Wuon-Shik; Lee, Moo-Sik; Kim, Kee-Sik; Park, Jeong Bae; Youn, Ho-Joong; Park, Chang-Gyu; Hong, Kyung-Soon; Kim, Jang-Young; Jeong, Jin-Won; Park, Jong Chun; Lim, Do-Sun; Kim, Moo Hyun; Woo, Jeong Taek

    2016-12-01

    It is still unclear which layer (intima or media) is mainly involved in increased carotid intima-media thickness (CIMT) by aging and also unclear regarding CIMT value suggesting high cardiovascular risk, although 75th percentile value of CIMT is known as a high risk in asymptomatic adults. We sought to find the changes of carotid intima thickness (CIT) and carotid media thickness (CMT) by aging and the 75th percentile value of CIMT in asymptomatic Korean adults. This is an observational cohort study. Carotid ultrasound findings (n=2204 from 12 hospitals) were prospectively collected. The carotid images were sent to Korea Research Institute of Standards and Science for analysis using specialized software which can measure intima and media wall also. Mean age was 58.1±13.5 years old (52% of men). Pearson's correlation coefficient between age and right CIMT (r=.489, Pvalue was 0.778 and 0.771 mm, respectively. Mean right CIT was 0.311±0.069 and 0.303±0.064 mm (P=.009), and mean right CMT was 0.391±0.124 and 0.388±0.131 mm (P=.694) in male and female, respectively. Left carotid ultrasound findings showed similar to the right one. An increased CIMT by aging was mainly due to increased CMT rather than CIT in asymptomatic adults. The 75th percentile values of right CIMT were 0.778 and 0.771 mm in asymptomatic Korean male and female adults, respectively. © 2016 John Wiley & Sons Ltd.

  10. Bilateral Internal Carotid Artery Occlusion Associated with the Antiphospholipid Antibody Syndrome

    Directory of Open Access Journals (Sweden)

    Pria Anand

    2014-03-01

    Full Text Available A 39-year-old woman presented with a right-hemispheric stroke 1 year after she had suffered a left-hemispheric stroke. Her diagnostic workup was notable for bilateral occlusions of the internal carotid arteries at their origins and a positive lupus anticoagulant antibody test. There was no evidence of carotid dissection or another identifiable cause for her carotid occlusions. These findings suggest that the antiphospholipid antibody syndrome may be implicated in the pathological changes that resulted in occlusions of the extracranial internal carotid arteries. Young stroke patients who present with unexplained internal carotid artery occlusions may benefit from testing for the presence of antiphospholipid antibodies.

  11. Estimated carotid-femoral pulse wave velocity has similar predictive value as measured carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Olsen, Michael; Greve, Sara; Blicher, Marie

    2016-01-01

    OBJECTIVE: Carotid-femoral pulse wave velocity (cfPWV) adds significantly to traditional cardiovascular (CV) risk prediction, but is not widely available. Therefore, it would be helpful if cfPWV could be replaced by an estimated carotid-femoral pulse wave velocity (ePWV) using age and mean blood...... pressure and previously published equations. The aim of this study was to investigate whether ePWV could predict CV events independently of traditional cardiovascular risk factors and/or cfPWV. DESIGN AND METHOD: cfPWV was measured and ePWV calculated in 2366 apparently healthy subjects from four age...

  12. Intravascular streaming and variable delivery to brain following carotid artery infusions in the Sprague-Dawley rat

    International Nuclear Information System (INIS)

    Saris, S.C.; Wright, D.C.; Oldfield, E.H.; Blasberg, R.G.

    1988-01-01

    Intracarotid artery infusions in animals are commonly performed in studies of the blood-brain barrier and in chemotherapy trials. Implicit in the analysis of these experiments is that the infusate will be distributed to the territory of the internal carotid artery in a manner that is proportional to blood flow. Fifteen Sprague-Dawley rats were studied to determine if poor infusate mixing with blood due to intravascular streaming occurred during intracarotid artery drug infusions and if it could be eliminated with fast retrograde infusion. In three experimental groups, a radiolabeled flow tracer-- 14 C-iodoantipyrine (IAP)--was infused retrograde through the external carotid artery into the common carotid artery at slow, medium, and fast rates (0.45, 1.5, and 5.0 ml/min). In a control group, IAP was injected intravenously (i.v.). Local isotope concentrations in the brain were determined by quantitative autoradiography, and the variability of isotope delivery was assessed in the frontoparietal cortex, temporal cortex, and caudate putamen of all animals. Streaming phenomena were manifest in all selected anatomic areas after the slow and medium rates of intraarterial infusion. After fast intracarotid infusion or i.v. injection, there was uniform distribution of isotope in the same brain regions

  13. Quality of life after carotid endarterectomy.

    Science.gov (United States)

    Abelha, Fernando José; Quevedo, Susana; Barros, Henrique

    2008-11-20

    Most studies documenting beneficial outcomes after carotid endarterectomy (CE) are limited to mortality and morbidity rates, costs, and length of hospital stay (LOS). Few have examined the dependency of patients and how they perceive their own health changes after surgery. The aim of the present study was to evaluate quality of life and independence in activities of daily living (ADL) and to study its determinants. Sixty-three patients admitted in the Post Anaesthesia Care Unit (PACU) after CE were eligible for this 14-month follow-up study. Patients were contacted 6 months after discharge to complete a Short Form-36 questionnaire (SF-36) and to have their dependency in ADL evaluated. Among 59 hospital survivors at 6 months follow-up, 43 completed the questionnaires. Sixty-three percent reported that their general level of health was better on the day they answered the questionnaire than 12 months earlier. Patients had worse SF-36 scores for all domains except bodily pain than a general urban population, and comparison with a group of patients 6 months after surgical ICU discharge showed no differences. Six months after PACU discharge, the Lawton Instrumental Activities of ADL Scale and the Katz Index of ADL demonstrated higher dependency scores (5.9 +/- 2.2 versus 4.3 +/- 2.4 and 0.3 +/- 0.8 versus 0.6 +/- 0.9, p < 0.001 and p = 0.047). Sixty-five percent and 33% were dependent in at least one activity in instrumental and personal ADL, respectively. Patients dependent in at least one ADL task had higher Revised Cardiac Risk Index (RCRI) scores (1.0 versus 1.5, p = 0.017). After controlling for multiple comparisons, no significant differences were found. Patients undergoing CE have improved self-perception of quality of life despite being more dependent. Almost all their scores are worse than those in an urban population. We could identify no predictors of greater dependency in ADL tasks six months after PACU discharge.

  14. Plasma non-uniformity in a symmetric radiofrequency capacitively-coupled reactor with dielectric side-wall: a two dimensional particle-in-cell/Monte Carlo collision simulation

    Science.gov (United States)

    Liu, Yue; Booth, Jean-Paul; Chabert, Pascal

    2018-02-01

    A Cartesian-coordinate two-dimensional electrostatic particle-in-cell/Monte Carlo collision (PIC/MCC) plasma simulation code is presented, including a new treatment of charge balance at dielectric boundaries. It is used to simulate an Ar plasma in a symmetric radiofrequency capacitively-coupled parallel-plate reactor with a thick (3.5 cm) dielectric side-wall. The reactor size (12 cm electrode width, 2.5 cm electrode spacing) and frequency (15 MHz) are such that electromagnetic effects can be ignored. The dielectric side-wall effectively shields the plasma from the enhanced electric field at the powered-grounded electrode junction, which has previously been shown to produce locally enhanced plasma density (Dalvie et al 1993 Appl. Phys. Lett. 62 3207-9 Overzet and Hopkins 1993 Appl. Phys. Lett. 63 2484-6 Boeuf and Pitchford 1995 Phys. Rev. E 51 1376-90). Nevertheless, enhanced electron heating is observed in a region adjacent to the dielectric boundary, leading to maxima in ionization rate, plasma density and ion flux to the electrodes in this region, and not at the reactor centre as would otherwise be expected. The axially-integrated electron power deposition peaks closer to the dielectric edge than the electron density. The electron heating components are derived from the PIC/MCC simulations and show that this enhanced electron heating results from increased Ohmic heating in the axial direction as the electron density decreases towards the side-wall. We investigated the validity of different analytical formulas to estimate the Ohmic heating by comparing them to the PIC results. The widespread assumption that a time-averaged momentum transfer frequency, v m , can be used to estimate the momentum change can cause large errors, since it neglects both phase and amplitude information. Furthermore, the classical relationship between the total electron current and the electric field must be used with caution, particularly close to the dielectric edge where the (neglected

  15. Clinical observations on the effect of carotid artery occlusion on cerebral blood flow mapped by xenon computed tomography and its correlation with carotid artery back pressure

    International Nuclear Information System (INIS)

    Steed, D.L.; Webster, M.W.; DeVries, E.J.; Jungreis, C.A.; Horton, J.A.; Sehkar, L.; Yonas, H.

    1990-01-01

    Xenon computed tomographic cerebral blood flow mapping was correlated with internal carotid artery stump pressures and clinical neurologic assessment during temporary internal carotid artery occlusion. One hundred fourteen patients with skull base tumors or intracranial aneurysms potentially requiring carotid resection or ligation underwent angiography, xenon CT cerebral blood flow mapping, and internal carotid artery blood pressure monitoring. The internal carotid artery was then temporarily occluded with a balloon catheter, stump pressure was measured through the catheter, and the xenon CT cerebral blood flow mapping was repeated. Adequate xenon CT cerebral blood flow was defined as greater than 30 cc/100 gm/min. All patients had normal xenon CT cerebral blood flow before internal carotid artery occlusion. During internal carotid artery occlusion, xenon CT cerebral blood flow was found to be normal (group I, 40 patients), globally reduced but still within the normal range (group II, 50 patients), or low in the distribution of the ipsilateral middle cerebral artery (group III, 13 patients). With balloon occlusion, an immediate neurologic deficit developed in 11 patients (9%) requiring deflation of the balloon preceding xenon CT cerebral blood flow measurement (group IV). In group I internal carotid artery blood pressure was 128 mm Hg. (range 85 to 171 mm Hg) with stump pressure 86 mm Hg (range 46 to 125 mm Hg). In group II internal carotid artery blood pressure was 130 mm Hg. (range 78 to 199 mm Hg), with stump pressure 86 mm Hg (range 31 to 150 mm Hg)

  16. Visualization and analysis of flow patterns of human carotid bifurcation by computational fluid dynamics

    International Nuclear Information System (INIS)

    Xue Yunjing; Gao Peiyi; Lin Yan

    2007-01-01

    Objective: To investigate flow patterns at carotid bifurcation in vivo by combining computational fluid dynamics (CFD)and MR angiography imaging. Methods: Seven subjects underwent contrast-enhanced MR angiography of carotid artery in Siemens 3.0 T MR. Flow patterns of the carotid artery bifurcation were calculated and visualized by combining MR vascular imaging post-processing and CFD. Results: The flow patterns of the carotid bifurcations in 7 subjects were varied with different phases of a cardiac cycle. The turbulent flow and back flow occurred at bifurcation and proximal of internal carotid artery (ICA) and external carotid artery (ECA), their occurrence and conformation were varied with different phase of a cardiac cycle. The turbulent flow and back flow faded out quickly when the blood flow to the distal of ICA and ECA. Conclusion: CFD combined with MR angiography can be utilized to visualize the cyclical change of flow patterns of carotid bifurcation with different phases of a cardiac cycle. (authors)

  17. Carotid plaque, intima-media thickness, and incident aortic stenosis

    DEFF Research Database (Denmark)

    Martinsson, Andreas; Östling, Gerd; Persson, Margaretha

    2014-01-01

    AS in a prospective population-based study. APPROACH AND RESULTS: A random sample of participants (age, 45-68 years) in the population-based Malmö Diet and Cancer Study underwent B-mode ultrasound with measurements of IMT and the presence of plaque in the common carotid artery (n=5079). Potential risk factors...

  18. Transcranial Doppler for detection of cerebral ischaemia during carotid endarterectomy

    DEFF Research Database (Denmark)

    Jørgensen, L G; Schroeder, T V

    1992-01-01

    We evaluated transcranial Doppler sonography (TCD) for the detection of cerebral ischaemia during carotid endarterectomy in 30 male and 14 female patients with ipsilateral focal cerebro-vascular symptoms. Surgery was performed during halothane-nitrous oxide anaesthesia with moderate hypocapnia...

  19. THREE-DIMENSIONAL ULTRASOUND AND STENOSIS OF INTERNAL CAROTID ARTERY

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2003-12-01

    Full Text Available Background. Elucidation of the ultrasound structure of the atherosclerotic plaque in stenosis of internal carotid artery may have important implications for carotid surgery. This study compares the ability of computer derived 3D ultrasound gray scale volumetric measurements to diferentiate between ultrasonic structure of symptomatic and asymptomatic carotid plaque causing more than 70% stenosis.Methods. Eightysix internal carotid artery stenoses (70–99%, 45 symptomatic, 41 asymptomatic were imaged with 3D ultrasound to obtain the whole volume of the atherosclerotic plaque. Digitalized sonograms were computerized and normalized to the gray scale median (GSM of blood (0 and vessel adventitia (200. Plaque GSM was obtained for the whole volume by computing the volume ratio between echolucent and echogenic areas. The plaque heterogeneity was obtained by computing the density of echogenic areas per volume unit. Parametric t test was used for statistic analysis.Results. Minimum volume GSM ratio (determining echolucency was higher for asymptomatic plaque (0.6 – CI 0.48– 0.91 versus 0.3 – CI 0.21–0.75: p = 0.002. Greater GSM heterogeneity was present in symptomatic plaque (6.8 – CI 2.5– 18.3 versus 0.41 – CI 0.2–3.4;.p = 0.0001.Conclusions. Volume ultrasound imaging that enables objective assessment of whole ultrasonic plaque structure is more sensitive that single longitudinal view sonography for differentiating between ultrasonic structure of symptomatic and asymptomatic plaque.

  20. Spontaneous Recanalization of Complete Internal Carotid Artery: A ...

    African Journals Online (AJOL)

    examination revealed global aphasia and right hemiplegia. No carotid bruits or heart murmurs were. ABSTRACT. Spontaneous recanalization of atherothrombotic extracranial cerebral arteries is rare vis-à-vis recanalization of intracranial vessels. The time course is unknown. The question is the advisability and timing of ...

  1. [Revascularization of the carotid and vertebral arteries in the elderly].

    Science.gov (United States)

    Illuminati, G; Bezzi, M; D'Urso, A; Giacobbi, D; Ceccanei, G; Vietri, F

    2004-01-01

    From January 1994 to July 2004, 323 patients underwent 348 revascularization of carotid bifurcation for atherosclerotic stenoses. Eighty eight patients (group A) were 75 year-old or older, whereas 235 (group B) were younger than 75 years. Postoperative mortality/neurologic morbidity rate was 1% in group A, and 1.4% in group B. At 5 years, patency and freedom from symptoms/stroke were, respectively, 91% and 92% in group A, and 89% and 91% in group B. None of these differences was statistically significant. In the same time period, 26 internal carotid arteries were revascularized in 24 patients, 75 or more aged, for a symptomatic kinking. Postoperative mortality/morbidity rate was absent, whereas, at 5 years, patency and freedom from symptoms/stroke were, respectively, 88% and 92%. Twelve vertebral arteries were revascularized in 12 patients, 75 or more aged, for invalidating symptoms of vertebrobasilar insufficiency. Postoperative mortality/neurologic morbidity rate was absent. In one case postoperative recurrence of symptoms occurred, despite a patent revascularization. Patency and freedom from symptoms/stroke were 84% and 75%, at 5 years. Revascularization of carotid and vertebral arteries in the elderly can be accomplished with good results, superposable to those of standard revascularization of carotid bifurcation in a younger patients' population.

  2. Dissecting aneurysm of the cervical internal carotid artery

    International Nuclear Information System (INIS)

    Itoh, Yoshihiro; Itoyama, Youichi; Fukumura, Akinobu; Matsukado, Yasuhiko; Kodama, Takafumi.

    1987-01-01

    On lifting a heavy case, a 51-year-old male experienced a sudden onset of headache with giddiness and clouded vision. A week later, vertigo and right hand numbness were added to his symptoms. The next day anisocoria (right > left) and dilation of the left retinal veins were noted. Cranial computed tomography (CT) scan appeared normal and there were no other remarkable neurological findings. The patient was treated conservatively for cerebral infarction, however, the headache worsened and diplopia occurred. Neurological examination on admission revealed nothing unusual except for left Horner's syndrome. Physical examination showed a palpable sausage-like painless tumor on the left side of the neck. Angiography showed a narrowing of the internal carotid artery in the cervical region with a small dissecting aneurysm at the C3 level. Cervical CT scan at the upper C3 level showed a low density lunar defect in the high density section of the enlarged left internal carotid artery. The patient was operated on by superficial temporal artery-middle cerebral artery anastomosis to increase the intracranial blood flow. Postoperatively the symptoms were quickly relieved. Angiography 1 month later showed less narrowing of the carotid artery, though the dissecting aneurysm still remained. Postoperative cervical CT scan showed the left internal carotid artery to be of normal size. The patient returned to his work in normal condition 2 months later. It is emphasized that cervical CT scan may be useful in the diagnosis of this unusual type of cervical dissecting aneurysm. (author)

  3. Association between internal carotid artery dissection and arterial tortuosity

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Argiolas, Giovanni Maria; Siotto, Paolo; Sumer, Suna; Wintermark, Max; Raz, Eytan; Sanfilippo, Roberto; Montisci, Roberto

    2015-01-01

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  4. A curve model for association of serum homocysteine with carotid ...

    African Journals Online (AJOL)

    Ma'anshan, China, enrolled in the cross-sectional study. Data collection included .... 1 drink /week, or never, and physical exercise was defined as .... P75), or n. (%), BMI =body mass index, CAD =Carotid artery disease, HTN = hypertension ...

  5. Screen for intracranial dural arteriovenous fistulae with carotid duplex sonography.

    Science.gov (United States)

    Tsai, L-K; Yeh, S-J; Chen, Y-C; Liu, H-M; Jeng, J-S

    2009-11-01

    Early diagnosis and management of intracranial dural arteriovenous fistulae (DAVF) may prevent the occurrence of stroke. This study aimed to identify the best carotid duplex sonography (CDS) parameters for screening DAVF. 63 DAVF patients and 170 non-DAVF patients received both CDS and conventional angiography. The use of seven CDS haemodynamic parameter sets related to the resistance index (RI) of the external carotid artery (ECA) for the diagnosis of DAVF was validated and the applicability of the best CDS parameter set in 20 400 patients was tested. The CDS parameter set (ECA RI (cut-off point = 0.7) and internal carotid artery (ICA) to ECA RI ratio (cut-off point = 0.9)) had the highest specificity (99%) for diagnosis of DAVF with moderate sensitivity (51%). Location of the DAVF was a significant determinant of sensitivity of detection, which was 70% for non-cavernous DAVF and 0% for cavernous sinus DAVF (pdetected abnormality in 92 of 20 400 patients. These abnormalities included DAVF (n = 25), carotid stenosis (n = 32), vertebral artery stenosis (n = 7), intracranial arterial stenosis (n = 6), head and neck tumour (n = 3) and unknown aetiology (n = 19). Combined CDS parameters of ECA RI and ICA to ECA RI ratio can be used as a screening tool for the diagnosis of DAVF.

  6. Percutaneous implantation of endoprostheses in the carotid arteries

    Directory of Open Access Journals (Sweden)

    Costa Jr. José Ribamar

    2003-01-01

    Full Text Available OBJECTIVE: To assess the in-hospital evolution of patients undergoing percutaneous stent placement in the carotid arteries. METHODS: From August 1996 to April 2001, we studied 86 patients with carotid arterial obliterative lesions > 70% who were treated with percutaneous stent placement in the carotid arteries. We assessed the rate of success of the implantation and of the procedure, the types of stents used, mortality rate, and neurological complications. RESULTS: Successful implantation was obtained in 98.9% of the cases, and the procedure was successful in 91.8%. The Wallstent was the most frequently used stent (73 patients - 77%. Cerebral strokes occurred as follows: 3 (3.2% transient ischemic attacks, 1 (1.1% minor stroke, and 3 (3.1% major strokes. One (1.1% patient died during hospitalization. CONCLUSION: The high rate of success of stent implantation (98.9% in addition to the low rate of cerebral stroke/death (4.2% showed the efficiency and safety of percutaneous stent placement in carotid arteries.

  7. Acute Carotid Artery Stent Thrombosis Due to Dual Antiplatelet Resistance

    International Nuclear Information System (INIS)

    Köklü, Erkan; Arslan, Şakir; Yüksel, İsa Öner; Bayar, Nermin; Koç, Pınar

    2015-01-01

    Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after the procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication

  8. Eight to ten years follow-up after carotid endarterectomy

    DEFF Research Database (Denmark)

    Knudsen Rathenborg, Lisbet; Sillesen, H; Schroeder, T

    1990-01-01

    Follow-up information was obtained on 185 patients who consecutively underwent carotid endarterectomy eight to ten years previously. Doppler ultrasound examination was performed in 59 patients who were still alive and living within 100 miles of the hospital. Using lifetable analysis, the annual r...

  9. Carotid endarterectomy in Durban - the first 10 years

    African Journals Online (AJOL)

    disease of the carotid bifurcation at the Metropolitan. Vascular Service (University of .... Three patients died of respiratory failure: aspiration pneumonia occurred in 1, aspiration pneumonia after emergency tracheostomy for an expanding wound haematoma in another, and acute respiratory obstruc- tion caused by laryngeal ...

  10. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  11. A case of unusual collateral circulation from internal carotid occlusion

    International Nuclear Information System (INIS)

    Jang, Il Jung; Choi, Byung So

    1972-01-01

    A 23 year old Korean boy was admitted to Dept. of Neurosurgery. Capital Army Hospital on Feb. 2, 1971 because of recurrent transient focal seizure and more weakness in the left extremities. During hospitalization, he recovered from focal seizure and motor weakness in the left extremities without specific therapy. Right carotid angiograms were performed. Right carotid angiograms show right internal carotic occlusion at the level of distal siphon of extradural level with good filling of ophthalmic artery of right. Extensive small vascular network developed intracranial region of right hemisphere. There are appearance to be two major anastomotic communication. 1. Via at the base of the brain. 2. Via the rete mirabile with external carotid artery. These angiographic finding were similar to that of the so-called 'cerebral rete mirabile' which was described in many literature. Etiology of cerebral rete mirabile is divided as to whether these represent true congenital vascular malformations or whether the 'rete mirabile' develops as a collateral because of a primary stenosis in the internal carotid arteries. Evidence for either theory is still inconclusive

  12. Association between internal carotid artery dissection and arterial tortuosity

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Piga, Mario [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology, Monserrato, Cagliari (Italy); Argiolas, Giovanni Maria; Siotto, Paolo [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology, di Cagliari (Italy); Sumer, Suna; Wintermark, Max [Neuroradiology Division, Neuroradiology, UVA Department of Radiology, Charlottesville, VA (United States); Raz, Eytan [New York University School of Medicine, Department of Radiology, New York, NY (United States); Sapienza University of Rome, Department of Neurology and Psychiatry, Rome (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria (A.O.U.), Department of Vascular Surgery, di Cagliari (Italy)

    2014-10-18

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  13. Aortic Baroreceptors Display Higher Mechanosensitivity than Carotid Baroreceptors

    Directory of Open Access Journals (Sweden)

    Eva On-Chai Lau

    2016-08-01

    Full Text Available Arterial baroreceptors are mechanical sensors that detect blood pressure changes. It has long been suggested that the two arterial baroreceptors, aortic and carotid baroreceptors, have different pressure sensitivities. However, there is no consensus as to which of the arterial baroreceptors are more sensitive to changes in blood pressure. In the present study, we employed independent methods to compare the pressure sensitivity of the two arterial baroreceptors. Firstly, pressure-activated action potential firing was measured by whole-cell current clamp with a high-speed pressure clamp system in primary cultured baroreceptor neurons. The results show that aortic depressor neurons possessed a higher percentage of mechano-sensitive neurons. Furthermore, aortic baroreceptor neurons show a lower pressure threshold than that of carotid baroreceptor neurons. Secondly, uniaxial stretching of baroreceptor neurons, that mimics the forces exerted on blood vessels, elicited a larger increase in intracellular Ca2+ rise in aortic baroreceptor neurons than in carotid baroreceptor neurons. Thirdly, the pressure-induced action potential firing in the aortic depressor nerve recorded in vivo was also higher. The present study therefore provides for a basic physiological understanding on the pressure sensitivity of the two baroreceptor neurons and suggests that aortic baroreceptors have a higher pressure sensitivity than carotid baroreceptors.

  14. Hypoplasia of the internal carotid artery with intercavernous anastomosis

    International Nuclear Information System (INIS)

    Chen, C.J.; Wang, L.J.; Wong, Y.C.; Chen, S.T.; Hsieh, F.Y.

    1998-01-01

    We report a symptomatic case of unilateral hypoplasia of the internal carotid artery with an intercavernous anastomosis, a very rare developmental anomaly. The symptoms were caused by occlusion of the proximal middle cerebral artery which possibly related to the haemodynamic stress caused by the anomalous intercavernous anastomosis. (orig.)

  15. Immediate Catheter Directed Thrombolysis for Thromboembolic Stroke During Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    E. Fletcher

    Full Text Available : Background: Carotid artery endarterectomy (CEA is a common procedure undertaken by vascular surgeons with over 5,000 procedures performed annually worldwide. Published rates of perioperative stroke range from 1.3% to 6.3%. Case report: A case is presented in which on-table intra-cranial angiography and catheter directed thrombolysis were used for a thromboembolic occlusion of the distal internal carotid artery (ICA and proximal middle cerebral artery (MCA. An 83-year-old lady developed a dense right hemiparesis while undergoing a CEA under local anaesthetic (LA. Immediate re-exploration of the endarterectomy did not reveal technical error. Intraoperative duplex scanning of the internal carotid artery revealed no detectable diastolic flow. On-table angiogram showed complete occlusion of the distal ICA and proximal MCA. Catheter directed administration of TPA was undertaken. The entire ICA and MCA were completely clear on a completion angiogram. The patient made a full neurological recovery. Discussion and conclusion: Prompt diagnosis and treatment with intraoperative catheter directed thrombolysis can resolve thromboembolic occlusion of the ICA/MCA. It is argued that performing CEA under LA is useful for immediate recognition of perioperative stroke. Furthermore, the advantage is highlighted of vascular surgeons having both the resources and skillset to perform on-table angiography and thrombolysis. Keywords: Carotid endarterectomy, Stroke, Thrombolysis, Thromboembolus, Local anaesthetic

  16. Resection of recurrent neck cancer with carotid artery replacement.

    Science.gov (United States)

    Illuminati, Giulio; Schneider, Fabrice; Minni, Antonio; Calio, Francesco G; Pizzardi, Giulia; Ricco, Jean-Baptiste

    2016-05-01

    The management of patients with recurrent neck cancer invading the carotid artery is controversial. The purpose of this study was to evaluate overall survival rate, primary patency of vascular reconstructions, and quality-adjusted life-years (QALYs) after en bloc resection of the carotid artery and tumor with in-line polytetrafluoroethylene (PTFE) carotid grafting, followed by radiotherapy. From 2000 to 2014, 31 consecutive patients with recurrent neck cancer invading the carotid artery underwent en bloc resection and simultaneous carotid artery reconstruction with a PTFE graft, which was associated in 18 cases with a myocutaneous flap. The primary tumor was a squamous cell carcinoma of the larynx in 17 patients and of the hypopharynx in 7, an undifferentiated carcinoma of unknown origin in 4, and an anaplastic carcinoma of the thyroid in 3. All of the patients underwent postoperative radiotherapy (50-70 Gy), and 10 of them also underwent chemotherapy (doxorubicin and cisplatin). None of the patients died or sustained a stroke during the first 30 days after the index procedure. Postoperative morbidity consisted of 6 transitory dysphagias, 3 vocal cord palsies, 2 wound dehiscences, 1 transitory mandibular claudication, and 1 partial myocutaneous flap necrosis. No graft infection occurred during follow-up. Fifteen patients (48%) died from metastatic cancer during a mean follow-up of 45.4 months (range, 8-175 months). None of the patients showed evidence of local recurrence, stroke, or thrombosis of the carotid reconstruction. The 5-year survival rate was 49 ± 10%. The overall number of QALYs was 3.12 (95% confidence interval, 1.87-4.37) with a significant difference between patients without metastasis at the time of redo surgery (n = 26; QALYs, 3.74) and those with metastasis (n = 5; QALYs, 0.56; P = .005). QALYs were also significantly improved in patients with cancer of the larynx (n = 17; QALYs, 4.69) compared to patients presenting with other types of

  17. Amaurosis fugax: risk factors and prevalence of significant carotid stenosis

    Directory of Open Access Journals (Sweden)

    Kvickström P

    2016-10-01

    Full Text Available Pia Kvickström,1 Bertil Lindblom,2,3 Göran Bergström,4,5 Madeleine Zetterberg2,3 1Department of Ophthalmology, Skaraborg Hospital, Skövde, 2Department of Clinical Neuroscience/Ophthalmology, Institute of Neuroscience and Physiology, The Sahlgrenska Academy at University of Gothenburg, 3Department of Ophthalmology, Sahlgrenska University Hospital, Mölndal, 4Department of Molecular and Clinical Medicine, The Sahlgrenska Academy at University of Gothenburg, 5Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Sweden Purpose: The purpose of this study was to describe clinical characteristics and prevalence of carotid stenosis in patients with amaurosis fugax (AF.Method: Patients diagnosed with AF and subjected to carotid ultrasound in 2004–2010 in Sahlgrenska University Hospital, Gothenburg (n=302, were included, and data were retrospectively collected from medical records.Results: The prevalence of significant carotid stenosis was 18.9%, and 14.2% of the subjects were subjected to carotid endarterectomy. Significant associations with risk of having ≥70% stenosis were male sex (adjusted odds ratio [aOR]: 2.62; 95% confidence interval [CI]: 1.26–5.46, current smoking (aOR: 6.26; 95% CI: 2.62–14.93, diabetes (aOR: 3.68; 95% CI: 1.37–9.90 and previous vasculitis (aOR: 10.78; 95% CI: 1.36–85.5. A majority of the patients (81.4% was seen by an ophthalmologist prior to the first ultrasound. Only 1.7% of the patients exhibited retinal artery emboli at examination.Conclusion: The prevalence of carotid stenosis among patients with AF is higher than has previously been demonstrated in stroke patients. An association with previously reported vascular risk factors and with vasculitis is seen in this patient group. Ocular findings are scarce. Keywords: amaurosis fugax, carotid stenosis, carotid ultrasound, giant cell arteritis, transient ischemic attack, transient monocular visual loss

  18. Cerebral hemodynamic changes and electroencephalography during carotid endarterectomy

    International Nuclear Information System (INIS)

    Algotsson, L.; Messeter, K.; Rehncrona, S.; Skeidsvoll, H.; Ryding, E.

    1990-01-01

    Some patients undergoing endarterectomy for occlusive carotid artery disease run a risk of brain ischemia during cross-clamping of the artery. The present study of 15 patients was undertaken to evaluate changes in cerebral blood flow (CBF), as measured with an intravenous (IV) tracer (133Xenon) technique, and to relate CBF changes to changes in the electroencephalogram (EEG). CBF was measured before and after induction of anesthesia, during cross-clamping of the carotid artery, after release of the clamps, and at 24 hours after the operation. All the patients were anesthetized with methohexitone, fentanyl, and nitrous oxide and oxygen. EEG was continuously recorded during the operation. Carotid artery shunts were not used. In 8 patients, cross-clamping of the carotid artery did not influence the EEG. In this group of patients, induction of anesthesia caused a 38% decrease in CBF, which presumably reflects the normal reaction to the anesthetic agent given. There were no further changes in CBF during cross-clamping. In 7 patients, the EEG showed signs of deterioration during the intraoperative vascular occlusion. In these patients, anesthesia did not cause any CBF change, whereas cross-clamping the artery induced a 33% decrease in CBF. In individual patients, the severity of EEG changes correlated with the decrease in CBF. The absence of a change in CBF by anesthesia and a decrease due to cross-clamping of the carotid artery may be explained by the presence of a more advanced cerebrovascular disease and an insufficiency to maintain CBF during cross-clamping

  19. Cerebral hemodynamic changes and electroencephalography during carotid endarterectomy

    Energy Technology Data Exchange (ETDEWEB)

    Algotsson, L.; Messeter, K.; Rehncrona, S.; Skeidsvoll, H.; Ryding, E. (University Hospital, Lund (Sweden))

    1990-05-01

    Some patients undergoing endarterectomy for occlusive carotid artery disease run a risk of brain ischemia during cross-clamping of the artery. The present study of 15 patients was undertaken to evaluate changes in cerebral blood flow (CBF), as measured with an intravenous (IV) tracer (133Xenon) technique, and to relate CBF changes to changes in the electroencephalogram (EEG). CBF was measured before and after induction of anesthesia, during cross-clamping of the carotid artery, after release of the clamps, and at 24 hours after the operation. All the patients were anesthetized with methohexitone, fentanyl, and nitrous oxide and oxygen. EEG was continuously recorded during the operation. Carotid artery shunts were not used. In 8 patients, cross-clamping of the carotid artery did not influence the EEG. In this group of patients, induction of anesthesia caused a 38% decrease in CBF, which presumably reflects the normal reaction to the anesthetic agent given. There were no further changes in CBF during cross-clamping. In 7 patients, the EEG showed signs of deterioration during the intraoperative vascular occlusion. In these patients, anesthesia did not cause any CBF change, whereas cross-clamping the artery induced a 33% decrease in CBF. In individual patients, the severity of EEG changes correlated with the decrease in CBF. The absence of a change in CBF by anesthesia and a decrease due to cross-clamping of the carotid artery may be explained by the presence of a more advanced cerebrovascular disease and an insufficiency to maintain CBF during cross-clamping.

  20. Efficacy of Carotid Artery Stenting by the Universal Protection Method.

    Science.gov (United States)

    Goto, Shunsaku; Ohshima, Tomotaka; Kato, Kyozo; Izumi, Takashi; Wakabayashi, Toshihiko

    2018-04-18

    To avoid distal plaques embolization during carotid artery stenting, we developed Universal Protection Method that combined the use of a proximal common carotid artery balloon, an external carotid artery balloon, and a distal internal carotid artery filter, with continuous flow reversal to the femoral vein. Herein, we assessed the efficacy of the Universal Protection Method by comparing stenting outcomes before and after its introduction. We assessed outcomes for 115 cases before and 41 cases after the Universal Protection Method was adopted (non-Universal Protection Method and Universal Protection Method groups, respectively). We then compared procedure details, magnetic resonance imaging (within 48 hours after the procedure), intraprocedural complications, and postoperative stroke rates. Ischemic stroke was not observed in the Universal Protection Method group, but 1 major stroke and 2 minor strokes were observed in the non-Universal Protection Method group. High-intensity areas were seen in 6 (15.0%) and 49 (42.6%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively (P = .001). Contrastingly, intraprocedural complications were observed in 9 (22.5%) and 21 (18.3%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively. Among these intraprocedural complication cases, high-intensity areas were observed in 1 case (11.1%) in the Universal Protection Method group and in 15 cases (71.4%) in the non-Universal Protection Method group. Universal Protection Method is a safe technique that is applicable to all patients undergoing carotid artery stenting, irrespective of individual risk factors. Notably, the incidence rates of both distal embolization and unexpected intraprocedural complications are low. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Surgical construction of a novel simulated carotid siphon in canines

    International Nuclear Information System (INIS)

    Tan Huaqiao; Li Minghua; Zhu Yueqi; Fang Chun; Wang Jue; Wu Chungen; Cheng Yingsheng; Xie Jian; Zhang He

    2008-01-01

    Objective: To develop in vivo carotid siphon models by surgical method using the shaped devices for testing the performance of covered stent specially designed for intracranial vascular diseases. Methods: Six carotid siphon-shaped devices were established using stereolithographic biomodeling and the lost-wax technique. Six canines underwent surgery to expose and isolate bilateral CCA. The right CCA origin was ligated and incised distal to the ligation point after the distal right CCA was temporarily closed. The distal left CCA was ligated and incised proximal to the ligation point after the left CCA origin was closed. The proximal isolated left CCA was passed through the shaped device. The distal isolated right CCA and the proximal isolated left CCA were anastomosed end-to-end. Finally, the shaped device of carotid siphon was fixed with suture and embedded in the left neck. The intraarterial DSA was performed on postprocedural 7 days, 2 weeks and 1 month. The morphological characteristics of carotid siphon models were visually evaluated by two observers. The patency of siphon model and the stenosis of anastomotic stoma were followed-up. Results: All animals tolerated the surgical procedure well with mean model time construction of 90 minutes. The morphological characteristics of siphon models were similar to those in human. The anastomotic stoma stenosis occurred in 2 siphon models, and thrombosis of anastomotic stoma in 1, but all siphons of these models were patent on post-procedural follow-up angiography. Conclusion: Surgical construction of an in vivo carotid siphon model of canine with shaped device is practically feasible. This model can be used for testing neurovascular devices. (authors)

  2. Carotid stiffness indicates risk of ischemic stroke and TIA in patients with internal carotid artery stenosis: the SMART study

    NARCIS (Netherlands)

    Dijk, Joke M.; van der Graaf, Yolanda; Grobbee, Diederick E.; Bots, Michiel L.

    2004-01-01

    Patients with a carotid artery stenosis, including those with an asymptomatic or moderate stenosis, have a considerable risk of ischemic stroke. Identification of risk factors for cerebrovascular disease in these patients may improve risk profiling and guide new treatment strategies. We

  3. Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting.

    Science.gov (United States)

    Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio

    2016-06-12

    Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.

  4. Efficacy of different types of self-expandable stents in carotid artery stenting for carotid bifurcation stenosis.

    Science.gov (United States)

    Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang

    2016-02-01

    Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.

  5. Carotid artery disease progression and related neurologic events after carotid endarterectomy.

    Science.gov (United States)

    Avgerinos, Efthymios D; Go, Catherine; Ling, Jennifer; Naddaf, Abdallah; Steinmetz, Amy; Abou Ali, Adham N; Makaroun, Michel S; Chaer, Rabih A

    2016-08-01

    During the last decade, there has been a dramatic improvement in best medical treatment for patients with vascular disease. Yet, there is a paucity of contemporary long-term data for restenosis and contralateral internal carotid artery (ICA) progression. This study assessed ipsilateral and contralateral disease progression and cerebrovascular events after carotid endarterectomy (CEA). A consecutive cohort of CEAs between January 1, 2000, and December 31, 2010, was retrospectively analyzed. End points were restenosis ≥50% and ≥70%, contralateral carotid disease progression (50%-69%, 70%-99%, or occlusion) and stroke. Survival analysis and Cox regression models were used to assess the effect of baseline predictors. During the 11-year study period, 1639 patients underwent 1782 CEAs (50.0% patch closure, 23.9% primary closure, 26.1% eversion, and 2.5% combined with coronary artery bypass grafting). The combined stroke/death rate was 2.6% overall and 1.8% in the asymptomatic cohort. The rate of restenosis ≥50% at 2, 5, and 10 years was 8.5%, 15.6%, 27.2%, and the rate for restenosis ≥70% was 3.4%, 6.5%, 10.2%, respectively. Restenosis ≥50% was predicted by hypertension (hazard ratio [HR], 2.09; P = .027), female gender (HR, 1.43; P = .042), and younger age (≤65 years; HR, 1.56; P = .016), but not by statins, surgical technique, symptoms, or other baseline risk factors. Restenoses remained asymptomatic in 125 of 148 (84.5%). Progression of contralateral ICA disease at 2, 5, and 10 years was estimated at 5.4%, 15.5%, and 46.8%, respectively. Contralateral progression was only predicted by smoking (HR, 1.74; P = .008). The stroke rate in patients with disease progression of the contralateral ICA was not different compared with those without progression (7.0% vs 3.3%; P = .063). Any-stroke rates at 2, 5, and 10 years were 4.6%, 7.3%, and 15.7%, respectively. Predictors were symptomatic lesion (HR, 1.48; P = .039), renal insufficiency, defined as a

  6. Carotid endarterectomy significantly improves postoperative laryngeal sensitivity.

    Science.gov (United States)

    Hammer, Georg Philipp; Tomazic, Peter Valentin; Vasicek, Sarah; Graupp, Matthias; Gugatschka, Markus; Baumann, Anneliese; Konstantiniuk, Peter; Koter, Stephan Herwig

    2016-11-01

    Iatrogenic injury of the vagus nerve or its branches during carotid endarterectomy (CEA) can result in globus sensation, dysphagia, and even vocal fold immobility. Knowledge of morphologic and functional laryngopharyngeal outcomes after CEA is poor. The present study was performed to determine potential iatrogenic damage to the laryngeal innervation after CEA. An area of particular interest was the supraglottic sensory threshold, which was examined by Fiberoptic Endoscopic Evaluation of Swallowing With Sensory Testing (FEESST; Pentax Medical Company, Montvale, NJ), a validated and safe method for the determination of the motor and sensory components of swallowing. FEESST was used preoperatively in 32 patients scheduled to undergo CEA and twice postoperatively to examine the motor and sensory components of swallowing. In this endolaryngeal examination, laryngopharyngeal sensory thresholds (in mm Hg) were defined as normal at 6.0 mm Hg APP, with a value >10.0 mm Hg APP indicating abolished laryngeal adductor reflex. Acoustic voice parameters were also analyzed for further functional changes of the larynx. The mean ± standard deviation preoperative FEESST measures showed no significant differences (P = .065) between the operated-on side (6.73 ± 1.73 mm Hg) and the opposite side (5.83 ± 1.68 mm Hg). At 2 days postoperatively, the threshold increased (P = .001) to 7.62 ± 1.98 mm Hg on the operated-on side. A laryngopharyngeal mucosal hematoma on the operated side was endoscopically detectable in eight patients (30.8%); in these patients, we found a markedly elevated (P = .021) measure of 9.50 ± 0.93 mm Hg. On the opposite (nonoperated-on) side of the laryngopharynx, the thresholds remained at the same level as preoperatively over all assessments (P >.05), whereas the differences between the operated and nonoperated-on sides and the hematoma and nonhematoma groups were highly significant (P = .004 and P = .001, respectively). Surprisingly, the

  7. Carotid artery ultrasonographic assessment in patients from the Fremantle Diabetes Study Phase II with carotid bruits detected by electronic auscultation.

    Science.gov (United States)

    Knapp, Arthur; Cetrullo, Violetta; Sillars, Brett A; Lenzo, Nat; Davis, Wendy A; Davis, Timothy M E

    2014-09-01

    Electronic auscultation appears superior to acoustic auscultation for identifying hemodynamic abnormalities. The aim of this study was to determine whether carotid bruits detected by electronic stethoscope in patients with diabetes are associated with stenoses and increased carotid intima-medial thickness (CIMT). Fifty Fremantle Diabetes Study patients (mean±SD age, 73.7±10.0 years; 38.0% males) with a bruit found by electronic auscultation and 50 age- and sex-matched patients with normal carotid sounds were studied. The degree of stenosis and CIMT were assessed from duplex ultrasonography. Patients with a bruit were more likely to have stenosis of ≥50% and CIMT of >1.0 mm than those without (odds ratios [95% confidence intervals]=14.0 [1.8-106.5] and 5.3 [1.8-15.3], respectively; both P=0.001). For the six patients with stenosis of ≥70%, five had a bruit, and one (with a known total occlusion) did not (odds ratio=5.0 [0.6-42.8]; P=0.22). The sensitivity and specificity of carotid bruit for stenoses of ≥50% were 88% and 58%, respectively; respective values for stenoses of ≥70% were 83% and 52%. The equivalent negative predictive values were 96% and 98%, and positive predictive values were 30% and 10%, respectively. Electronic recording of carotid sounds for later interpretation is convenient and reliable. Most patients with stenoses had an overlying bruit. Most bruits were false positives, but ultrasonography is justified to document extent of disease; CIMT measurement will identify increased vascular risk in most of these patients. The absence of a bruit was rarely a false-negative finding, suggesting that these patients can usually be reassured that they do not have hemodynamically important stenosis.

  8. A CT study of the prevalence of carotid artery calcification in dental patients

    International Nuclear Information System (INIS)

    Yoon, Suk Ja; Lee, Jae Seo; Yoon, Woong

    2006-01-01

    Stroke is one of the leading causes of death in Korea. Atherosclerotic disease in the carotid artery bifurcation is the most common cause of stroke. The carotid artery calcification is easily appreciated by CT(Computed tomography). CT is often taken in a dental hospital for the diagnosis of inflammation. injury, cyst or tumor on maxillofacial region. However, there was no report of carotid artery calcification on CT in dental patients. The presence of carotid artery calcification was evaluated by an experienced radiologist on CT scans of 287 patients (166 males, 121 females, average age 42, range 6 to 86 years) and the medical history of the patient and the interpretation of CT were reviewed. Carotid artery calcification was detected on CT scans of 57 patients (19.8%; 35 males, 22 females). All the male patients with carotid artery calcification were older than 50, and all the female patients with carotid artery calcification were older than 60. Among the 57 patients, 10 had Diabetes mellitus, 20 had cardiovascular disease, 3 had history of stroke and 3 underwent radiation therapy for head and neck cancer. Carotid artery calcification was not included in the interpretation of CT of dental patients except one patient. The prevalence of carotid artery calcification on CT of dental patients was about 20% in this study. Carotid artery calcification should be included in the interpretation of CT of dental patients

  9. Prevalence of carotid and pulp calcifications: a correlation using digital panoramic radiographs

    International Nuclear Information System (INIS)

    Clark, Stephen J.; Scheetz, James P.; Khan, Zafrulla; Farman, Allan G.; Horsley, Scott H.; Beckstrom, Brice

    2009-01-01

    To compare the prevalence of pulp calcification with that of carotid calcification using digital panoramic dental radiographs. Digital panoramic radiographs of patients at a dental oncology clinic were included if (1) the carotid artery bifurcation region was visible bilaterally and (2) the patient had non-restored or minimally restored molars and/or canines. An endodontist evaluated the images for pulpal calcifications in the selected teeth. An oral and maxillofacial radiologist independently evaluated the same images for calcifications in the carotid bifurcation region. Odds-ratio and Pearson χ 2 were used for data analysis. Presence of pulpal calcification was also evaluated as a screening test for the presence of carotid calcification. A total of 247 panoramic radiographs were evaluated. 32% (n=80) had pulpal calcifications and 25% (n=61) had carotid calcifications with 12% (n=29) having both carotid and pulp calcifications. A significantly higher prevalence of both pulp and carotid calcification was found in subjects older than age 60 years compared to younger age groups. Accuracy of pulpal calcification in screening for carotid calcification was 66.4%. Both pulp and carotid calcifications were more prevalent in older individuals. The presence of pulp calcification was not a strong predictor for the presence of carotid calcification. (orig.)

  10. Prevalence of carotid and pulp calcifications: a correlation using digital panoramic radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Stephen J. [School of Dentistry, University of Louisville, Department of Periodontics, Endodontics and Dental Hygiene, Louisville, KY (United States); Scheetz, James P.; Khan, Zafrulla [University of Louisville, Department of Diagnostic Sciences, Prosthodontics and Restorative Dentistry, School of Dentistry, Louisville, KY (United States); Farman, Allan G. [School of Dentistry, University of Louisville, Department of Periodontics, Endodontics and Dental Hygiene, Louisville, KY (United States); Horsley, Scott H.; Beckstrom, Brice

    2009-03-15

    To compare the prevalence of pulp calcification with that of carotid calcification using digital panoramic dental radiographs. Digital panoramic radiographs of patients at a dental oncology clinic were included if (1) the carotid artery bifurcation region was visible bilaterally and (2) the patient had non-restored or minimally restored molars and/or canines. An endodontist evaluated the images for pulpal calcifications in the selected teeth. An oral and maxillofacial radiologist independently evaluated the same images for calcifications in the carotid bifurcation region. Odds-ratio and Pearson {chi}{sup 2} were used for data analysis. Presence of pulpal calcification was also evaluated as a screening test for the presence of carotid calcification. A total of 247 panoramic radiographs were evaluated. 32% (n=80) had pulpal calcifications and 25% (n=61) had carotid calcifications with 12% (n=29) having both carotid and pulp calcifications. A significantly higher prevalence of both pulp and carotid calcification was found in subjects older than age 60 years compared to younger age groups. Accuracy of pulpal calcification in screening for carotid calcification was 66.4%. Both pulp and carotid calcifications were more prevalent in older individuals. The presence of pulp calcification was not a strong predictor for the presence of carotid calcification. (orig.)

  11. Serum albumin is an important prognostic factor for carotid blowout syndrome

    International Nuclear Information System (INIS)

    Lu Hsuehju; Chen Kuowei; Chen Minghuang; Tzeng Chenghwai; Chang Peter Muhsin; Yang Muhhwa; Chu Penyuan; Tai Shyhkuan

    2013-01-01

    Carotid blowout syndrome is a severe complication of head and neck cancer. High mortality and major neurologic morbidity are associated with carotid blowout syndrome with massive bleeding. Prediction of outcomes for carotid blowout syndrome patients is important for clinicians, especially for patients with the risk of massive bleeding. Between 1 January 2001 and 31 December 2011, 103 patients with carotid blowout syndrome were enrolled in this study. The patients were divided into groups with and without massive bleeding. Prognostic factors were analysed with proportional hazard (Cox) regressions for carotid blowout syndrome-related prognoses. Survival analyses were based on the time from diagnosis of carotid blowout syndrome to massive bleeding and death. Patients with massive bleeding were more likely to have hypoalbuminemia (albumin 1000 cells/μl, P=0.041) and hypoalbuminemia (P=0.010) were important to prognosis. Concurrent chemoradiotherapy (P=0.007), elevated lactate dehydrogenase (>250 U/l; P=0.050), local recurrence (P=0.022) and hypoalbuminemia (P=0.038) were related to poor prognosis in carotid blowout syndrome-related death. In multivariate analysis, best supportive care and hypoalbuminemia were independent factors for both carotid blowout syndrome-related massive bleeding (P=0.000) and carotid blowout syndrome-related death (P=0.013), respectively. Best supportive care and serum albumin are important prognostic factors in carotid blowout syndrome. It helps clinicians to evaluate and provide better supportive care for these patients. (author)

  12. Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Kizilkilic, Osman; Tercan, Fahri; Tuerkoez, Riza; Yildirim, Tuelin

    2005-01-01

    The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery

  13. Vertebrocarotid collateral in extracranial carotid artery occlusions: digital subtraction angiography findings

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent; Kizilkilic, Osman; Tercan, Fahri; Tuerkoez, Riza; Yildirim, Tuelin

    2005-02-01

    The internal and external carotid arteries are usually considered occluded distal to a common carotid artery occlusion but some collateral vessels may provide blood keeping the internal and external carotid arteries patent distal to the occlusion. Most common communication in such a case is diversion of blood from muscular branches of the vertebral artery to occipital branch of the external carotid artery which in turn could maintain blood flow into the internal carotid artery, a condition called carotid steal. We encountered vertebrocarotid anastomoses maintaining the patency of carotid circulation in six patients. Patients were four females and two males, ages ranging from 40 to 67 (mean age: 56) years. Five of the patients had ischemic cerebral symptoms. The origin of the external carotid artery was occluded in two and the whole common carotid artery in the remaining four patients. Two patients had double steal, carotid and subclavian at the same time. There was also severe stenosis or occlusion of at least one other major extracranial cerebral artery in all the cases. This concomitant involvement of the second extracranial cerebral artery was thought to be the main reason for the development of vertebrocarotid collateral. In contrast to most of the previously published reports claiming the inadequacy of angiography when compared with colour Doppler ultrasonography, angiography finely depicted the distal patency of the carotid circulation and all the collaterals in detail in every case. Selective injection of the vertebral artery ipsilateral to the occlusion, is the key to demonstrate distal patency of the carotid circulation in cases of proximal carotid occlusion. Demonstration of patency of the distal circulation is very important because some of the patients might get benefit from a reconstructive surgery.

  14. New ischaemic brain lesions on MRI after stenting or endarterectomy for symptomatic carotid stenosis: a substudy of the International Carotid Stenting Study (ICSS)

    NARCIS (Netherlands)

    Bonati, Leo H.; Jongen, Lisa M.; Haller, Sven; Flach, H. Zwenneke; Dobson, Joanna; Nederkoorn, Paul J.; Macdonald, Sumaira; Gaines, Peter A.; Waaijer, Annet; Waajier, Annet; Stierli, Peter; Jäger, H. Rolf; Lyrer, Philippe A.; Kappelle, L. Jaap; Wetzel, Stephan G.; van der Lugt, Aad; Mali, Willem P.; Brown, Martin M.; van der Worp, H. Bart; Engelter, Stefan T.; Koelemaij, M. J. W.; Majoie, C. B. L. M.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Flach, H. Z.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van der Lugt, A.; van Urk, H.; Verhagen, H. J. M.; de Borst, G. J.; de Kort, G. A. P.; Jongen, L. M.; Kappelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F. L.; van der Worp, H. B.; Bonati, L. H.; Engelter, S. T.; Fluri, F.; Haller, S.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E.-W.; Stierli, P.

    2010-01-01

    BACKGROUND: The International Carotid Stenting Study (ICSS) of stenting and endarterectomy for symptomatic carotid stenosis found a higher incidence of stroke within 30 days of stenting compared with endarterectomy. We aimed to compare the rate of ischaemic brain injury detectable on MRI between the

  15. Association between age and risk of stroke or death from carotid endarterectomy and carotid stenting : A meta-analysis of pooled patient data from four randomised trials

    NARCIS (Netherlands)

    Howard, George; Roubin, Gary S.; Jansen, Olav; Hendrikse, Jeroen; Halliday, Alison; Fraedrich, Gustav; Eckstein, Hans Henning; Calvet, David; Bulbulia, Richard; Bonati, Leo H.; Becquemin, Jean Pierre; Algra, Ale; Brown, Martin M.; Ringleb, Peter A.; Brott, Thomas G.; Mas, Jean Louis

    2016-01-01

    Background: Age was reported to be an effect-modifier in four randomised controlled trials comparing carotid artery stenting (CAS) and carotid endarterectomy (CEA), with better CEA outcomes than CAS outcomes noted in the more elderly patients. We aimed to describe the association of age with

  16. Determination of bilateral symmetry of carotid artery structure and function in children and adolescents

    Directory of Open Access Journals (Sweden)

    Uithoven KE

    2017-01-01

    Full Text Available Katelyn E Uithoven,1 Justin R Ryder,2 Roland Z Brown,3 Kyle D Rudser,3 Nicholas G Evanoff,1 Donald R Dengel,1,2 Aaron S Kelly2,4 1School of Kinesiology, University of Minnesota, 2Department of Pediatrics, University of Minnesota Medical School, 3Division of Biostatistics, School of Public Health, University of Minnesota, 4Department of Medicine, University of Minnesota Medical School, Minneapolis, MN, USA Abstract: The carotid artery represents an ideal location for noninvasive assessment of subclinical atherosclerosis in youth. Examination of arterial structure and function is generally conducted in the left common carotid. However, if the left common carotid is inaccessible or provides a poor acoustic window, it is unknown if the right common carotid can provide comparable values. The symmetry of carotid arteries in youth with high-resolution ultrasound was compared. Participants (N=230 [121 females], 13.8±2.9 years old were assessed for carotid intima media thickness (cIMT, carotid lumen diameter (cLD, carotid incremental elastic modulus (cIEM, carotid diameter compliance (cDC, carotid cross-sectional compliance (cCSC, carotid diameter distensibility (cDD, and carotid cross-sectional distensibility (cCSD. No significant differences (P>0.05 all were found for cIMT (0.49±0.09 vs 0.49±0.08 mm, cIEM (1095±382 vs 1116±346 mmHg, cDC (0.01±0.0 vs 0.01±0.0 mm/mmHg, cCSC (0.01±0.001/mmHg vs 0.01±0.001/mmHg, cDD (14.0%±3.16% vs 13.7%±3.18%, and cCSD (30.1%±7.37% vs 29.4%±7.36%. Significant differences were found for cLD (6.06±0.62 mm vs 6.33±0.64 mm, P<0.001. The majority of measures for arterial structure and function are comparable between the left and right common carotid arteries. There were differences present for cLD; however, these discrepancies are likely due to anatomical differences between the left and right common carotid arteries. Therefore, if the left common carotid is unable to be assessed properly, the right common

  17. Uniaxial Tensile Properties of Atherosclerotic Carotid Artery After Mobilization of Pushing on Qiao-Gong: A Safety Study Using an Animal Model of Carotid Atherosclerosis.

    Science.gov (United States)

    Qi, Ji; Zhang, Shaoqun; Zhang, Lei; Ping, Ruiyue; Ping, Kaike; Ye, Da; Shen, Honggui; Chen, Yili; Li, Yikai

    2018-02-01

    This study aimed to preliminarily explore the effects of the soft tissue mobilization of pushing on Qiao-Gong (MPQ) on biomechanical properties of the carotid artery using an animal model of carotid atherosclerosis (CAS). Fifty rabbits were randomly divided into 4 groups: animals with CAS treated with MPQ (CAS-MPQ [n = 15]); animals with CAS treated without MPQ (CAS [n = 15]); normal animals treated with MPQ (normal-MPQ [n = 10]); and a blank control group (n = 10). The MPQ procedure consisted of soft tissue mobilization of the Qiao-Gong acupoint on the front edge of the sternocleidomastoid muscle applied from top to bottom, by flat pushing with the thumb repeatedly for 20 times. Disease in the CAS models was induced by carotid artery balloon injury combined with a high-fat diet for 12 weeks. At the end of modeling, carotid color Doppler ultrasonography examination was performed to confirm which animal models were successfully induced with CAS, excluding model rabbits without typical CAS at the same time. Then, MPQ was applied on rabbits in the CAS-MPQ and the normal-MPQ groups for 3 weeks. By contrast, rabbits in the other 2 groups were fed normally without MPQ. Uniaxial failure tests were later performed on carotid arteries in all 4 groups, and at the end of the study, a 2-way factorial analysis of variance of the results was conducted. (1) At the end of modeling, 10 rabbits in the CAS-MPQ group and 9 in the CAS group were included with typical carotid atherosclerotic characteristics. (2) Young's elastic modulus of the rabbit carotid artery increased more significantly in the CAS-MPQ group than the CAS group. (3) Compared with normal rabbit carotid arteries, atherosclerotic carotid arteries had lower levels of ultimate stress and ultimate strain but higher levels of ultimate load. The uniaxial tensile mechanical properties of the rabbit atherosclerotic carotid artery were impaired after MPQ. Copyright © 2018. Published by Elsevier Inc.

  18. Magnetic resonance imaging and three-dimensional ultrasound of carotid atherosclerosis: mapping regional differences.

    Science.gov (United States)

    Krasinski, Adam; Chiu, Bernard; Fenster, Aaron; Parraga, Grace

    2009-04-01

    To evaluate differences in carotid atherosclerosis measured using magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS). Ten subject volunteers underwent carotid 3DUS and MRI (multislice black blood fast spin echo, T1-weighted contrast, double inversion recovery, 0.5 mm in-plane resolution, 2 mm slice, 3.0 T) within 1 hour. 3DUS and MR images were manually segmented by two observers providing vessel wall and lumen contours for quantification of vessel wall volume (VWV) and generation of carotid thickness maps. MRI VWV (1040 +/- 210 mm(3)) and 3DUS VWV (540 +/- 110 mm(3)) were significantly different (P Power Doppler US confirmed that heterogeneity in the common carotid artery in all patients resulted from apparent flow disturbances, not atherosclerotic plaque. MRI and 3DUS VWV were significantly different and carotid maps showed homogeneous thickness differences and heterogeneity in specific regions of interest identified as MR flow artifacts in the common carotid artery.

  19. Periodontal disease and carotid atherosclerosis: A meta-analysis of 17,330 participants.

    Science.gov (United States)

    Zeng, Xian-Tao; Leng, Wei-Dong; Lam, Yat-Yin; Yan, Bryan P; Wei, Xue-Mei; Weng, Hong; Kwong, Joey S W

    2016-01-15

    The association between periodontal disease and carotid atherosclerosis has been evaluated primarily in single-center studies, and whether periodontal disease is an independent risk factor of carotid atherosclerosis remains uncertain. This meta-analysis aimed to evaluate the association between periodontal disease and carotid atherosclerosis. We searched PubMed and Embase for relevant observational studies up to February 20, 2015. Two authors independently extracted data from included studies, and odds ratios (ORs) with 95% confidence intervals (CIs) were calculated for overall and subgroup meta-analyses. Statistical heterogeneity was assessed by the chi-squared test (Pperiodontal disease was associated with carotid atherosclerosis (OR: 1.27, 95% CI: 1.14-1.41; Pperiodontal disease was associated with carotid atherosclerosis; however, further large-scale, well-conducted clinical studies are needed to explore the precise risk of developing carotid atherosclerosis in patients with periodontal disease. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. The Impact of Carotid Artery Stenting on Cerebral Perfusion, Functional Connectivity, and Cognition in Severe Asymptomatic Carotid Stenosis Patients

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2017-08-01

    Full Text Available Background and purposeAsymptomatic carotid artery stenosis can lead to not only stroke but also cognition impairment. Although it has been proven that carotid artery stenting (CAS can reduce the risk of future strokes, the effect of CAS on cognition is conflicting. In recent years, pulsed arterial spin labeling (pASL MRI and resting-state functional MRI (R-fMRI have been employed in cognitive impairment studies. For the present study, cognition is evaluated in severe asymptomatic carotid artery stenosis patients undergoing CAS, and the mechanisms underlying the cognitive change are explored by pASL MRI and R-fMRI.Materials and methodsWe prospectively enrolled 24 asymptomatic, severe (≥70%, unilateral internal carotid artery stenosis patients, who were expecting the intervention of CAS. Cognition assessment (including the Montreal Cognitive Assessment Beijing Version, the Minimum Mental State Examination, the Digit Symbol Test, the Rey Auditory Verbal Learning Test, and the Verbal Memory Test and an integrated MRI program (pASL MRI, and R-fMRI were administered 7 days before and 3 months after CAS.Results16 subjects completed the follow-up study. After stenting, significant improvement in the scores of the MMSE, the Verbal Memory test, and the delayed recall was found. No significant difference was found in the scores of the Montreal Cognitive Assessment Beijing Version, the Digit Symbol Test, and the immediate recall. After CAS treatment, asymptomatic carotid artery stenosis patients showed increased perfusion in the left frontal gyrus, increased amplitude of low-frequency fluctuation (ALFF in the right precentral gyrus, and increased connectivity to the posterior cingulate cortex (PCC in the right supra frontal gyrus. However, no significant correlations were found between these imaging changes and cognition assessments.ConclusionSuccessful CAS can partly improve cognition in asymptomatic carotid artery stenosis patients. The cognition

  1. Imaging diagnosis of dural and direct cavernous carotid fistulae

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daniela dos; Monsignore, Lucas Moretti; Nakiri, Guilherme Seizem; Cruz, Antonio Augusto Velasco e; Colli, Benedicto Oscar; Abud, Daniel Giansante, E-mail: danisantos2404@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2014-07-15

    Arteriovenous fistulae of the cavernous sinus are rare and difficult to diagnose. They are classified into dural cavernous sinus fistulae or direct carotid-cavernous fistulae. Despite the similarity of symptoms between both types, a precise diagnosis is essential since the treatment is specific for each type of fistula. Imaging findings are remarkably similar in both dural cavernous sinus fistulae and carotid-cavernous fistulae, but it is possible to differentiate one type from the other. Amongst the available imaging methods (Doppler ultrasonography, computed tomography, magnetic resonance imaging and digital subtraction angiography), angiography is considered the gold standard for the diagnosis and classification of cavernous sinus arteriovenous fistulae. The present essay is aimed at didactically presenting the classification and imaging findings of cavernous sinus arteriovenous fistulae. (author)

  2. CrossFit-related cervical internal carotid artery dissection.

    Science.gov (United States)

    Lu, Albert; Shen, Peter; Lee, Paul; Dahlin, Brian; Waldau, Ben; Nidecker, Anna E; Nundkumar, Anoop; Bobinski, Matthew

    2015-08-01

    CrossFit is a high-intensity strength and conditioning program that has gained popularity over the past decade. Potential injuries associated with CrossFit training have been suggested in past reports. We report three cases of cervical carotid dissection that are associated with CrossFit workouts. Patient 1 suffered a distal cervical internal carotid artery (ICA) dissection near the skull base and a small infarct in Wernicke's area. He was placed on anticoagulation and on follow-up has near complete recovery. Patient 2 suffered a proximal cervical ICA dissection that led to arterial occlusion and recurrent middle cerebral artery territory infarcts and significant neurological sequelae. Patient 3 had a skull base ICA dissection that led to a partial Horner's syndrome but no cerebral infarct. While direct causality cannot be proven, intense CrossFit workouts may have led to the ICA dissections in these patients.

  3. Imaging of carotid artery disease: from luminology to function?

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, J.H. [University Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2003-10-01

    There have been tremendous advances in our ability to image atheromatous disease, particularly in the carotid artery, which is accessible and large enough to image. The repertoire of methodology available is growing, giving anatomical information on luminal narrowing which is approaching the level at which conventional carotid angiography will become very uncommon as CT and contrast-enhanced MR angiographic techniques become the norm. More exciting is the tentative ability to perform functional plaque imaging addressing enhancement patterns and macrophage activity using MR or positron-emission tomography techniques. These techniques, once rigorously evaluated, may, in addition to complex mathematical modelling of plaque, eventually allow us to assess true plaque risk. Time will best judge whether we will be able to move from the use of simple luminology to assessment of plaque function. (orig.)

  4. Imaging of carotid artery disease: from luminology to function?

    International Nuclear Information System (INIS)

    Gillard, J.H.

    2003-01-01

    There have been tremendous advances in our ability to image atheromatous disease, particularly in the carotid artery, which is accessible and large enough to image. The repertoire of methodology available is growing, giving anatomical information on luminal narrowing which is approaching the level at which conventional carotid angiography will become very uncommon as CT and contrast-enhanced MR angiographic techniques become the norm. More exciting is the tentative ability to perform functional plaque imaging addressing enhancement patterns and macrophage activity using MR or positron-emission tomography techniques. These techniques, once rigorously evaluated, may, in addition to complex mathematical modelling of plaque, eventually allow us to assess true plaque risk. Time will best judge whether we will be able to move from the use of simple luminology to assessment of plaque function. (orig.)

  5. 18FDG PET and ultrasound echolucency in carotid artery plaques

    DEFF Research Database (Denmark)

    Graebe, Martin; Pedersen, Sune F; Højgaard, Liselotte

    2010-01-01

    OBJECTIVES: The objective was to evaluate inflammation in echolucent carotid artery plaques. BACKGROUND: Ultrasound echolucency of carotid artery plaques has been proven to differentiate patients at high risk of stroke. On the other hand, positron emission tomography (PET) of plaques with the use...... for ultrasound and PET imaging. Plaque standardized gray scale medians (GSM) were measured in longitudinal ultrasound images to quantitate echolucency, and GSM values were compared with FDG PET uptake quantified by maximum standardized uptake values (SUV). Symptomatic plaques were compared with contralateral...... plaques ranged from high to low inflammatory activity, as depicted with PET. Quantitative FDG SUV differentiated asymptomatic from symptomatic plaques, whereas GSM values did not. There was a positive correlation between CD68 expression and FDG uptake (r = 0.50, p = 0.04). CONCLUSIONS: Our results...

  6. Morning Glory Syndrome with Carotid and Middle Cerebral Artery Vasculopathy.

    Science.gov (United States)

    Nezzar, Hachemi; Mbekeani, Joyce N; Dalens, Helen

    2015-12-01

    To report a case of incidental asymptomatic atypical morning glory syndrome (MGS) with concomitant ipsilateral carotid and middle cerebral dysgenesis. A 6-year-old child was discovered to have incidental findings of MGS, with atypia. All visual functions were normal including vision and stereopsis. Neuroimaging revealed ipsilateral carotid and middle cerebral vascular narrowing without associated collateral vessels or cerebral ischemia commonly seen in Moyamoya disease. Subsequent annual examinations have been stable, without signs of progression. This case demonstrates disparity between structural aberrations and final visual and neurological function and reinforces the association between MGS and intracranial vascular disruption. Full ancillary ophthalmic and neuroimaging studies should be performed in all patients with MGS with interval reassessments, even when the patient is asymptomatic and functionally intact.

  7. Atherosclerosis of the carotid artery: evaluation by magnetic resonance angiography.

    Science.gov (United States)

    Wildy, K S; Yuan, C; Tsuruda, J S; Ferguson, M S; Wen, N; Subramaniam, D S; Strandness, D E

    1996-01-01

    Carotid artery atherosclerotic plaques (APs) can lead to brain ischemia, an event shown to correlate with both the degree of stenosis and the composition of the AP. Currently, accurate estimates of stenosis can be obtained by either x-ray angiography or three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA). Our purpose was to determine whether three-dimensional TOF MRA images could also provide information on plaque location, morphology, and composition. Seven pre-endarterectomy patients underwent three-dimensional TOF MRA. After endarterectomy, plaque histology was evaluated. Three-dimensional TOF MRA images contained sufficient soft tissue contrast to differentiate the plaques from the surrounding tissues in all cases. Estimation of plaque morphology had 80% correlation with histology. Finally, intraplaque hemorrhage and calcification were deplicted as regions of moderately high and very low intensity, respectively. These preliminary results suggest that three-dimensional TOF MRA may be useful in studying the development and progression of carotid atherosclerosis.

  8. Bilateral Carotid Artery Dissection after High Impact Road Traffic Accident

    Directory of Open Access Journals (Sweden)

    Michael Kelly

    2008-11-01

    Full Text Available A 58 year old man was involved in a high impact road traffic incident and was admitted for observation. Asymptomatic for the first 24 hours, he collapsed with symptoms and signs consistent with a cerebrovascular accident. Computed tomography angiogram (CTA and Magnetic resonance angiogram (MRA demonstrated bilateral internal carotid artery dissections and a left middle cerebral artery infarct. It was not considered appropriate to attempt stenting or other revascularistation. The patient was treated with heparin prior to starting warfarin. He made a partial recovery and was discharged to a rehabilitation facility. This case is a reminder of carotid dissection as an uncommon but serious complication of high speed motor vehicle accident, which may be silent initially. Literature Review suggests risk stratification before relevant radiological screening at risk patients. Significant advances in CTA have made it the diagnostic tool of choice, but ultrasound is an important screening tool.

  9. Aberrant internal carotid artery in the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Keun Tak; Kang, Hyun Koo [Dept. of Radiology, Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2014-10-15

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  10. Aberrant internal carotid artery in the middle ear

    International Nuclear Information System (INIS)

    Roh, Keun Tak; Kang, Hyun Koo

    2014-01-01

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  11. Cataract surgery in a case of carotid cavernous fistula

    Science.gov (United States)

    Nair, Akshay Gopinathan; Praveen, Smita Vittal; Noronha, Veena Olma

    2014-01-01

    A carotid-cavernous fistula (CCF) is an abnormal communication between the cavernous sinus and the carotid arterial system. The ocular manifestations include conjunctival chemosis, proptosis, globe displacement, raised intraocular pressure and optic neuropathy. Although management of CCF in these patients is necessary, the ophthalmologist may also have to treat other ocular morbidities such as cataract. Cataract surgery in patients with CCF may be associated with many possible complications, including suprachoroidal hemorrhage. We describe cataract extraction surgery in 60-year-old female with bilateral spontaneous low-flow CCF. She underwent phacoemulsification via a clear corneal route under topical anesthesia and had an uneventful postoperative phase and recovered successfully. Given the various possible ocular changes in CCF, one must proceed with an intraocular surgery with caution. In this communication, we wish to describe the surgical precautions and the possible pitfalls in cataract surgery in patients with CCF. PMID:25370401

  12. Carotid body denervation prevents fasting hyperglycemia during chronic intermittent hypoxia.

    Science.gov (United States)

    Shin, Mi-Kyung; Yao, Qiaoling; Jun, Jonathan C; Bevans-Fonti, Shannon; Yoo, Doo-Young; Han, Woobum; Mesarwi, Omar; Richardson, Ria; Fu, Ya-Yuan; Pasricha, Pankaj J; Schwartz, Alan R; Shirahata, Machiko; Polotsky, Vsevolod Y

    2014-10-01

    Obstructive sleep apnea causes chronic intermittent hypoxia (IH) and is associated with impaired glucose metabolism, but mechanisms are unknown. Carotid bodies orchestrate physiological responses to hypoxemia by activating the sympathetic nervous system. Therefore, we hypothesized that carotid body denervation would abolish glucose intolerance and insulin resistance induced by chronic IH. Male C57BL/6J mice underwent carotid sinus nerve dissection (CSND) or sham surgery and then were exposed to IH or intermittent air (IA) for 4 or 6 wk. Hypoxia was administered by decreasing a fraction of inspired oxygen from 20.9% to 6.5% once per minute, during the 12-h light phase (9 a.m.-9 p.m.). As expected, denervated mice exhibited blunted hypoxic ventilatory responses. In sham-operated mice, IH increased fasting blood glucose, baseline hepatic glucose output (HGO), and expression of a rate-liming hepatic enzyme of gluconeogenesis phosphoenolpyruvate carboxykinase (PEPCK), whereas the whole body glucose flux during hyperinsulinemic euglycemic clamp was not changed. IH did not affect glucose tolerance after adjustment for fasting hyperglycemia in the intraperitoneal glucose tolerance test. CSND prevented IH-induced fasting hyperglycemia and increases in baseline HGO and liver PEPCK expression. CSND trended to augment the insulin-stimulated glucose flux and enhanced liver Akt phosphorylation at both hypoxic and normoxic conditions. IH increased serum epinephrine levels and liver sympathetic innervation, and both increases were abolished by CSND. We conclude that chronic IH induces fasting hyperglycemia increasing baseline HGO via the CSN sympathetic output from carotid body chemoreceptors, but does not significantly impair whole body insulin sensitivity. Copyright © 2014 the American Physiological Society.

  13. Applying the payoff time framework to carotid artery disease management.

    Science.gov (United States)

    Yuo, Theodore H; Roberts, Mark S; Braithwaite, R Scott; Chang, Chung-Chou H; Kraemer, Kevin L

    2013-11-01

    and Asymptomatic stenosis of the carotid arteries is associated with stroke. Carotid revascularization can reduce the future risk of stroke but can also trigger an immediate stroke. The objective was to model the generic relationship between immediate risk, long-term benefit, and life expectancy for any one-time prophylactic treatment and then apply the model to the use of revascularization in the management of asymptomatic carotid disease. In the "payoff time" framework, the possibility of losing quality-adjusted life-years (QALYs) because of revascularization failure is conceptualized as an "investment" that is eventually recouped over time, on average. Using this framework, we developed simple mathematical forms that define relationships between the following: perioperative probability of stroke (P); annual stroke rate without revascularization (r0); annual stroke rate after revascularization, conditional on not having suffered perioperative stroke (r1); utility levels assigned to the asymptomatic state (ua) and stroke state (us); and mortality rates (λ). In patients whose life expectancy is below a critical life expectancy (CLE = P/(1-P)r0-r1, the "investment" will never pay off, and revascularization will lead to loss of QALYs, on average. CLE is independent of utilities assigned to the health states if a rank ordering exists in which ua > us. For clinically relevant values (P = 3%, r0 = 1%, r1 = 0.5%), the CLE is approximately 6.4 years, which is longer than published guidelines regarding patient selection for revascularization. In managing asymptomatic carotid disease, the payoff time framework specifies a CLE beneath which patients, on average, will not benefit from revascularization. This formula is suitable for clinical use at the patient's bedside and can account for patient variability, the ability of clinicians who perform revascularization, and the particular revascularization technology that is chosen.

  14. SUTURE NON-SUTSRE CIRCUMFERENTIAL REPAIR OF CAROTID ARTERY

    Directory of Open Access Journals (Sweden)

    Jafar Nader

    1969-01-01

    Full Text Available plastic adhesives, normal butyl cyanoacrylate monomer, isobutyl cyanoacrylate monomer and methyl 2 _ cyaooacrylate monomer, have been utilized in a comparative study with 5-{ silk suture in the repair of transected carotid arteries. Follow _ up arteriog ramS indicate isobutyl cyanoacrylate monomer and normal butyl cyanoacrylate monomer as having the most impressive rerults with only tWO thrombosis each. The silk suture had three thromboses and the adhesive methyl 2 _ cyanoacrylate monomer had nine, one of which a delayed

  15. Carotid angioplasty and stent placement for restenosis after endarterectomy

    International Nuclear Information System (INIS)

    Kadkhodayan, Yasha; Moran, Christopher J.; Cross, DeWitte T.; Derdeyn, Colin P.

    2007-01-01

    Recurrent carotid stenosis following endarterectomy is a common complication, and reoperation may be associated with increased morbidity. The goal of this study was to determine the procedural safety and long-term complication rates of carotid angioplasty and stenting for recurrent stenosis. Of 248 consecutive carotid angioplasty and/or stenting procedures performed at our institution between March 1996 and November 2005, 83 procedures for recurrent stenosis following endarterectomy were performed in 75 patients (mean age 68 years; 43 men, 32 women) without cerebral protection devices. The patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and long-term complication rates were calculated. Recurrent stenosis was reduced from a mean of 80.6% to no significant stenosis in 82 of 83 procedures. The procedural stroke rate was 3 out of 83 procedures (3.6%). The procedural transient ischemic attack (TIA) rate was 2 out of 83 procedures (2.4%). Mean follow-up was 22.4 months (range 0.1 to 86.7 months) with at least 6 months follow-up for 54 of 83 procedures (65%). There were five TIAs and no strokes on follow-up (new TIAs at 25.5 and 43.4 months; recurrent TIAs at 1, 11.1, and 12 months, all with normal angiograms). The composite 30-day stroke, myocardial infarction, or death rate was 5 of 83 procedures (6.0%). In this series, angioplasty and stenting were effective in relieving stenosis secondary to recurrent carotid disease after endarterectomy, and have low rates of ischemic complications. (orig.)

  16. Plaque Characteristics of Patients with Symptomatic Mild Carotid Artery Stenosis.

    Science.gov (United States)

    Takai, Hiroki; Uemura, Juniti; Yagita, Yoshiki; Ogawa, Yukari; Kinoshita, Keita; Hirai, Satoshi; Ishihara, Manabu; Hara, Keijirou; Toi, Hiroyuki; Matsubara, Shunji; Nishimura, Hirotake; Uno, Masaaki

    2018-03-20

    Carotid revascularization may be considered for severe stenosis, but its use for symptomatic mild stenosis (<50%) with vulnerable plaque or ulcer remains uncertain. The characteristics of patients with symptomatic mild stenosis who underwent revascularization are reviewed. The subjects of this study were 18 patients with symptomatic mild stenosis (<50%) on angiography from among 175 patients who underwent revascularization in our department. The plaques were evaluated by black-blood magnetic resonance imaging (BB-MRI) and ultrasonography (US) and classified into 2 types: type 1 (n = 15), a lesion with an ulcer or mobile plaque or thrombosis on angiography or US; and type 2 (n = 3), a lesion without any of the above. Fourteen patients underwent carotid endarterectomy (CEA), and 4 patients underwent carotid artery stenting. The stenosis on angiography was 27.2% ± 10.7 (5%-41%), and the area carotid artery stenosis rate on US was 69.8 ± 14.5% (44.5%-97%). The stenosis rate of these 2 methods was not at all correlated. In type 1 plaque that underwent CEA, 10 of 11 patients had vulnerable plaque by histopathology, and 1 patient had thrombus on the plaque by operative findings. In type 2 plaque that underwent CEA, all patients had vulnerable plaque by histopathology. During the follow-up period, none of the patients had restenosis or stroke. The findings of US and BB-MRI in patients with symptomatic mild stenosis (<50%) on angiography are important for determining treatment. If BB-MRI or US shows the findings of vulnerable plaque in mild stenosis, surgical treatment may be considered for these patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  17. Closure technique after carotid endarterectomy influences local hemodynamics.

    Science.gov (United States)

    Harrison, Gareth J; How, Thien V; Poole, Robert J; Brennan, John A; Naik, Jagjeeth B; Vallabhaneni, S Rao; Fisher, Robert K

    2014-08-01

    Meta-analysis supports patch angioplasty after carotid endarterectomy (CEA); however, studies indicate considerable variation in practice. The hemodynamic effect of a patch is unclear and this study attempted to elucidate this and guide patch width selection. Four groups were selected: healthy volunteers and patients undergoing CEA with primary closure, trimmed patch (5 mm), or 8-mm patch angioplasty. Computer-generated three-dimensional models of carotid bifurcations were produced from transverse ultrasound images recorded at 1-mm intervals. Rapid prototyping generated models for flow visualization studies. Computational fluid dynamic studies were performed for each model and validated by flow visualization. Mean wall shear stress (WSS) and oscillatory shear index (OSI) maps were created for each model using pulsatile inflow at 300 mL/min. WSS of OSI >0.3 were considered pathological, predisposing to accretion of intimal hyperplasia. The resultant WSS and OSI maps were compared. The four groups comprised 8 normal carotid arteries, 6 primary closures, 6 trimmed patches, and seven 8-mm patches. Flow visualization identified flow separation and recirculation at the bifurcation increased with a patch and was related to the patch width. Computational fluid dynamic identified that primary closure had the fewest areas of low WSS or elevated OSI but did have mild common carotid artery stenoses at the proximal arteriotomy that caused turbulence. Trimmed patches had more regions of abnormal WSS and OSI at the bifurcation, but 8-mm patches had the largest areas of deleteriously low WSS and high OSI. Qualitative comparison among the four groups confirmed that incorporation of a patch increased areas of low WSS and high OSI at the bifurcation and that this was related to patch width. Closure technique after CEA influences the hemodynamic profile. Patching does not appear to generate favorable flow dynamics. However, a trimmed 5-mm patch may offer hemodynamic benefits over an 8

  18. Hemodynamic study of cervical carotid arteries using DSA

    International Nuclear Information System (INIS)

    Kumashiro, Masayuki; Araki, Osamu; Matsunaga, Morio; Shigeyasu, Makio

    1986-01-01

    Although intravenous digital subtraction angiography (IVDSA) has been widely utilized as a means of morphological examination for the detection of intracranial or extracranial vascular lesions, it has thus for contributed little to quantitative assessment in hemodynamics. In the present study, a fundamental analysis of the hemodynamics on the cervical carotid artery was performed with a relative perfusion efficiency (Rath et al., 1979). This was not related to the measurement of time, such as the mean transit time, but was based on Sapirstein's principle. After the intravenous administration of the contrast material, dynamic DSA was performed using our equipment, Shimadzu DAR-100. After setting the region of interest in common carotid arteries on DSA images by means of a microdensitometer (Sakura PDS-15) combined with a computer (NEC ACOS-460), time-density curves were obtained on both sides. Thereafter, the RPE was calculated as a ratio of two integrals from the zero time to the earlier peak time of the time-density curves with respect to the time. The flow model with the hydro-dynamic system was used to detect the relationship between the RPEs and the ratios of the actual flows in the system. The results of this experiment showed a high correlation between the RPEs and the flows (r = 0.85, p < 0.001). In normal subjects (n = 28), the mean of the RPEs was 1.07 ± 0.27 (S.D.). The RPEs showed significantly lower values in the 5 patients with severe stenosis of the internal carotid artery (0.76 ± 0.15, p < 0.02), as well as even more significantly lower values in the 9 patients with a complete occlusion of the internal carotid artery (0.64 ± 0.19, p < 0.001). The RPE measurement with IVDSA has been shown to be useful for recognizing the cervical hemodynamic changes in patients with occlusive cervicovascular disease. (author)

  19. Aortic Baroreceptors Display Higher Mechanosensitivity than Carotid Baroreceptors

    OpenAIRE

    Lau, Eva On-Chai; Lo, Chun-Yin; Yao, Yifei; Mak, Arthur Fuk-Tat; Jiang, Liwen; Huang, Yu; Yao, Xiaoqiang

    2016-01-01

    Arterial baroreceptors are mechanical sensors that detect blood pressure changes. It has long been suggested that the two arterial baroreceptors, aortic and carotid baroreceptors, have different pressure sensitivities. However, there is no consensus as to which of the arterial baroreceptors are more sensitive to changes in blood pressure. In the present study, we employed independent methods to compare the pressure sensitivity of the two arterial baroreceptors. Firstly, pressure-activated act...

  20. Bilateral Carotid Artery Dissection after High Impact Road Traffic Accident

    OpenAIRE

    Michael Kelly; Marcus Bradley; Ankur Srivastava

    2008-01-01

    A 58 year old man was involved in a high impact road traffic incident and was admitted for observation. Asymptomatic for the first 24 hours, he collapsed with symptoms and signs consistent with a cerebrovascular accident. Computed tomography angiogram (CTA) and Magnetic resonance angiogram (MRA) demonstrated bilateral internal carotid artery dissections and a left middle cerebral artery infarct. It was not considered appropriate to attempt stenting or other revascularistation. The patient was...

  1. Radiation-Induced Carotid Artery Stenosis: A Comprehensive Review of the Literature

    OpenAIRE

    Xu, Jiaping; Cao, Yongjun

    2014-01-01

    In recent decades, with the improvement of radiotherapy (RT) technology and comprehensive treatment, the survival rate of head and neck malignancies has gained remarkable progress. Vascular injury and subsequent carotid stenosis following RT, as the backbone of treatment, have received increasing attention. Many investigations have demonstrated that radiation can result in the increase in carotid intima-media thickness, carotid stenosis and consequently lead to a higher risk of cerebrovascula...

  2. Angioplasty of symptomatic high-grade internal carotid artery stenosis with intraluminal thrombus: therapeutic approach

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.; Mayol, A. [Seccion de Neurorradiologia Intervencionista, Servicio de Radiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Gil-Peralta, A.; Gonzalez-Marcos, J.R. [Servicio de Neurologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Boza, F. [Servicio de Neurofisiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Ruano, J. [Unidad de Cuidados Intensivos, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain)

    2004-04-01

    Intraluminal thrombus in the internal carotid artery (ICA) is usually found in patients with severe atheromatous stenosis. Having reviewed 300 carotid angioplasties for symptomatic >70% ICA stenosis, we found three patients (1%) with intraluminal thrombus. Conservative treatment with anticoagulants and double antiplatelet coverage can result in lysis of the thrombus without severe risks. Percutaneous transluminal angioplasty and stenting, preferably with distal protection, can be an excellent alternative to carotid endarterectomy. (orig.)

  3. Missed Total Occlusion Due to the Occipital Artery Arising from the Internal Carotid Artery

    International Nuclear Information System (INIS)

    Ustunsoz, Bahri; Gumus, Burcak; Koksal, Ali; Koroglu, Mert; Akhan, Okan

    2007-01-01

    A 56-year-old man was referred for digital subtraction angiography (DSA) with an ultrasound diagnosis of right proximal internal carotid artery (ICA) stenosis for possible carotid artery stenting. DSA revealed total occlusion of the ICA and an occipital artery arising from the stump and simulating continuation of the ICA. An ascending pharyngeal artery also arose from the same occipital artery. This case is of interest because this is a rare variation besides being a cause of misdiagnosis at carotid ultrasound

  4. Reconstruction of Injured Carotid Artery in a Comatose Patient

    Directory of Open Access Journals (Sweden)

    Arben Zenelaj

    2014-06-01

    Full Text Available A man 30 years old,was brought to the emergency department after being injured on the left side of the neck area.Massive bleeding from the wound caused by glass was observed.The patient was in cerebral coma and hemorrahagic shock.The eye pupils remained isochoric during and after the operation.He was taken immediately at the surgery room.The bleeding was stopped by using external compression.Exposure of the left neck blood vessels was carried out.The left common carotid artery and internal jugular vein was revealed.A provisory Pruitt-Inahara shunt was put in the common carotid artery,while teh injured vein was ligated.The suture of the left common carotid artery using Prolen 6-0 completed the procedure.After the surgery the patient was transferred to the intensive care unit.About two hours later he woke up,conscious.The left thoracic drainage because of the hemothorax was applied in the second postoperative day.The patient was lively and discharged from the hospitall in the 14-th postoperative day.The right facial paresis and mild left side hemiparesis persisted.Two months after the event no residual neurologic deficits were observed. [Cukurova Med J 2014; 39(3.000: 598-601

  5. Complications in percutaneous transluminal stenting for carotid artery stenosis

    International Nuclear Information System (INIS)

    Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng

    2007-01-01

    Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)

  6. Carotid-cavernous fistula after functional endoscopic sinus surgery.

    Science.gov (United States)

    Karaman, Emin; Isildak, Huseyin; Haciyev, Yusuf; Kaytaz, Asim; Enver, Ozgun

    2009-03-01

    Carotid-cavernous fistulas (CCFs) are anomalous communications between the carotid arterial system and the venous cavernous sinus. They can arise because of spontaneous or trauma causes. Most caroticocavernous fistulas are of spontaneous origin and unknown etiology. Spontaneous CCF may also be associated with cavernous sinus pathology such as arteriosclerotic changes of the arterial wall, fibromuscular dysplasia, or Ehler-Danlos syndrome. Traumatic CCFs may occur after either blunt or penetrating head trauma. Their clinical presentation is related to their size and to the type of venous drainage, which can lead to a variety of symptoms, such as visual loss, proptosis, bruit, chemosis, cranial nerve impairment, intracranial hemorrhage (rare), and so on. Treatment by endovascular transarterial embolization with electrolytically detachable coils is a very effective method for CCF with good outcomes. Carotid-cavernous fistulas have been rarely reported after craniofacial surgery and are uncommon pathologies in otolaryngology practice. In this study, we report a 40-year-old woman with CCF secondary to blunt trauma of functional endoscopic sinus surgery.

  7. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  8. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  9. The role of completion imaging following carotid artery endarterectomy.

    Science.gov (United States)

    Ricco, Jean-Baptiste; Schneider, Fabrice; Illuminati, Giulio; Samson, Russell H

    2013-05-01

    A variety of completion imaging methods can be used during carotid endarterectomy to recognize technical errors or intrinsic abnormalities such as mural thrombus or platelet aggregation, but none of these methods has achieved wide acceptance, and their ability to improve the outcome of the operation remains a matter of controversy. It is unclear if completion imaging is routinely necessary and which abnormalities require re-exploration. Proponents of routine completion imaging argue that identification of these abnormalities will allow their immediate correction and avoid a perioperative stroke. However, much of the evidence in favor of this argument is incidental, and many experienced vascular surgeons who perform carotid endarterectomy do not use any completion imaging technique and report equally good outcomes using a careful surgical protocol. Furthermore, certain postoperative strokes, including intracerebral hemorrhage and hyperperfusion syndrome, are unrelated to the surgical technique and cannot be prevented by completion imaging. This controversial subject is now open to discussion, and our debaters have been given the task to clarify the evidence to justify their preferred option for completion imaging during carotid endarterectomy. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  10. Interventional therapy of traumatic pseudoaneurysms in internal carotid artery siphon

    International Nuclear Information System (INIS)

    Tang Jun; Shang Jianqiang; Chen Jie; Li Fengxin; Liu Yanjun

    2007-01-01

    Objective: To determine the methods and results of treating traumatic pseudoaneurysms in siphon segment of internal carotid artery (ICA)by interventional therapy. Methods: Twelve cases of traumatic pseudoaneurysms in siphon segment of internal carotid artery were treated. The collateral circulation of Willis circle was observed after DSA. Different methods of treatment were applied according to the collateral circulation of Willis circle. Ten cases were treated by occlusion of ICA completely, 1 case was embolized by guglielmi detachable coil (GDC) only. Results: Nine of 12 treated by occlusion of ICA were cured. In the 3 cases who had poor collateral of Willis circle, one was cured by GDC embolization alone; one died 48 hours later after ICA occlusion though his consciousness and the activity of extremities were normal during the temporary balloon test occlusion (BTO) of ICA. One died during the training to improve the collateral of the Willis circle. Conclusion: ICA embolization is feasible for treatment of traumatic pseudoaneurysms in siphon segment of internal carotid artery after evaluating the collateral circulation of Willis circle. (authors)

  11. Spasm induced by protection balloon during carotid artery stenting

    International Nuclear Information System (INIS)

    Tsutsumi, Masanori; Kazekawa, Kiyoshi; Onizuka, Masanari

    2007-01-01

    The PercuSurge system is a distal balloon embolic protection device used for carotid artery stenting (CAS). We performed a retrospective study on the prognosis and clinical effects of spasms induced by the PercuSurge GuardWire system (PercuSurge-induced spasm). We performed CAS in 118 carotid stenoses using the PercuSurge system. Of the 118 procedures, 31 (26.3%) of the patients experienced PercuSurge-induced spasm, and all underwent postoperative follow-up studies by cerebral angiography and antiplatelet treatment. On follow-up angiograms obtained a mean of 5.2 months (range 3-10 months) after CAS, all 31 PercuSurge-induced spasms had disappeared, and no delayed stenosis was found at the sites where the spasms had occurred. No ischemic events due to the spasms occurred during a mean follow-up of 13 months (range 3-32 months). In the hands of physicians experienced in endovascular surgery, CAS using the PercuSurge system is a safe method with which to treat patients with carotid stenosis. Our study demonstrated that PercuSurge-induced spasms had no morphological or clinical adverse effects. (author)

  12. Software-assisted CT-postprocessing of the carotid arteries

    International Nuclear Information System (INIS)

    Gerhards, A.; Raab, P.; Herber, S.; Kreitner, K.F.; Mildenberger, P.

    2004-01-01

    Purpose: A software assistant for automatic evaluation of CT-angiograms (CTA) was developed. It should enable the visualization of the vessel lumen and the quantitative evaluation of a stenosis. CTA examinations of patients with suspected carotid artery stenoses were used for the evaluation of the software assistant. Materials and Methods: Twelve Patients with suspected highgrade stenosis of the carotid arteries underwent a CTA examination using a multislice CT scanner. The data were analyzed and evaluated using the new software assistant. The results were compared with the data of digital subtraction angiography (DSA) of these patients. Results: The time of digital postprocessing with the new software-assistant took about six minutes on average. Contour extraction of the vessel, MIP and curved MPR (c-MPR) and orthogonal cross-sectional images of the vessels were calculated, followed by an automatic quantification of stenosis by the use of the C-MPR. A good correlation was found between CTA and DSA data regarding the stenosis grade (r=0.82). Furthermore, some information could be provided about the plaque morphology. Conclusion: The software-assisted detection and analysis of carotid artery stenosis with the new developed program is possible within a justifiable time. DSA- and CTA-data did not show a significant difference in stenosis grading. Further development of software tools could lead to a better characterization of plaque morphology. (orig.) [de

  13. Conjunctival-corneal melt in association with carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Rosalind MK Stewart

    2008-10-01

    Full Text Available Rosalind MK Stewart1, Say Aun Quah1, Dan Q Nguyen2, Stephen B Kaye11Royal Liverpool University Hospital, Liverpool, UK; 2Bristol Eye Hospital, Bristol, UKPurpose: To report a case of severe conjunctival-corneal melt in association with carotid artery stenosis.Methods: Observational case report.Results: A 76-year-old man with a history of bilateral severe carotid artery occlusion and nonarteritic ischemic optic neuropathy developed a spontaneous bulbar conjunctival defect. Despite intensive lubrication, and attempts at surgical closure including an amniotic membrane patch graft, it progressed with subsequent adjacent corneal perforation. Thorough investigations revealed no underlying disease, except markedly delayed episcleral vessel filling on anterior segment fluorescein angiography.Conclusions: Neovascularisation is a known factor in the inhibition of ulceration. In light of the findings in this report, ocular ischemia should be considered as a cause or contributing factor in the differential diagnosis of conjunctival-corneal melt.Keywords: conjunctival melt, corneal melt, ocular ischemia, carotid artery stenosis

  14. Carotid disease in diabetic patients undergoing coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Shahid, M.; Abid, A.R.; Dar, M.A.; Noeman, A.; Amin, S.; Azhar, M.

    2012-01-01

    Objective: To compare the severity of carotid artery disease in diabetic and non-diabetic patients undergoing coronary artery bypass grafting. Methods: From January to June 2008, 379 patients undergoing elective coronary artery bypass surgery were preoperatively evaluated for the presence of carotid stenoses by duplex scanning. Patients were divided into two groups, Group I, 156 (41.2%) diabetic patients and Group II, 223 (58.8%) non-diabetic patients. Results: There were 314 (82.8%) males and 65 (17.2%) females with a mean age of 57.2+-9.1 years. In diabetic group there were 125 (80.1%) males and 31 (19.9%) females with a mean age of 56.3+-8.9 years. Left main stem stenosis was present in 59 (37.8%) diabetics and 45 (20.2%) non-diabetics (p 70% stenosis was present in 20 (5.3%) with 13 (8.3%) diabetics and 7 (3.1%) non-diabetics (p<0.025). Stenosis of 50-70% was observed in 30 (7.9%) of which 17 (10.9%) were diabetics and 13 (5.8%) were non-diabetics. Conclusion: Presence of diabetes mellitus is associated with diffuse coronary artery disease and significant carotid artery disease in patients undergoing coronary artery bypass grafting. (author)

  15. Assessing carotid atherosclerosis by fiber-optic multispectral photoacoustic tomography

    Science.gov (United States)

    Hui, Jie; Li, Rui; Wang, Pu; Phillips, Evan; Bruning, Rebecca; Liao, Chien-Sheng; Sturek, Michael; Goergen, Craig J.; Cheng, Ji-Xin

    2015-03-01

    Atherosclerotic plaque at the carotid bifurcation is the underlying cause of the majority of ischemic strokes. Noninvasive imaging and quantification of the compositional changes preceding gross anatomic changes within the arterial wall is essential for diagnosis of disease. Current imaging modalities such as duplex ultrasound, computed tomography, positron emission tomography are limited by the lack of compositional contrast and the detection of flow-limiting lesions. Although high-resolution magnetic resonance imaging has been developed to characterize atherosclerotic plaque composition, its accessibility for wide clinical use is limited. Here, we demonstrate a fiber-based multispectral photoacoustic tomography system for excitation of lipids and external acoustic detection of the generated ultrasound. Using sequential ultrasound imaging of ex vivo preparations we achieved ~2 cm imaging depth and chemical selectivity for assessment of human arterial plaques. A multivariate curve resolution alternating least squares analysis method was applied to resolve the major chemical components, including intravascular lipid, intramuscular fat, and blood. These results show the promise of detecting carotid plaque in vivo through esophageal fiber-optic excitation of lipids and external acoustic detection of the generated ultrasound. This imaging system has great potential for serving as a point-ofcare device for early diagnosis of carotid artery disease in the clinic.

  16. Early outcomes after carotid angioplasty with stenting performed by neurologists

    Directory of Open Access Journals (Sweden)

    Bathala Lokesh

    2010-01-01

    Full Text Available Aims: To evaluate the results of carotid artery angioplasty and stenting (CAS in treating extracranial carotid artery stenosis performed by neurologists in our center and compare the results with other large published series. Materials and Methods: Data for all patients who underwent CAS from January 2003 through November 2007, was retrieved from the Nanjing Stroke Registry. Perioperative and post-procedural complications within 30 days following stenting were analyzed and compared with that from other series. A total number of 75 patients were enrolled, with a mean age of 65.9 ± 8.8 years, and 64 (85.3% of them were male. Results: Procedural success was achieved in 74 patients (98.7%. Pre-treatment stenosis was 73.8 ± 14.9 and post-treatment residual stenosis was less than 10%. Thirty-four patients (45.3% had bilateral carotid artery disease and seven (9.3% had tandem stenosis. The neurological complication rate was 3.9% (one major and two minor strokes. Bradycardia in four (5.3% and hypotension in 13 (17.3% were observed during procedures. Using the Fischer′s exact t test, the complication rate compared with the large published series did not reveal any statistically significant difference (P > 0.05. Conclusions: We conclude that neurologists, with adequate training, can develop and add this technical skill to the existing cognitive skill of vascular neurology and safely perform stenting.

  17. [Arterial sequelae of pregnancy hypertension. Detection by carotid piezogram].

    Science.gov (United States)

    Meyer-Heine, A; Asquer, J C; Lagrue, G

    1989-01-01

    High blood pressure (HTA) is characterized by elevation of pression, but also by modifications of arterial pulse wave. Carotid piezograms were used to evaluate arterial pulse wave. Diastolic blood pressure is significantly correlated with dicrotic notch pressure. The duration of dicrotic notch is negatively correlated with arterial wall elasticity. Thus by carotid piezogram analysis one can determine the respective participation of arterial wall elasticity, peripheral resistance and cardiac factors in blood pressure elevation. Carotid piezograms were measured in 97 women (mean age 27, 8 y), with previous hypertensive pregnancy and apparently cured (mean blood pressure 122-74 mmHg at time of examination). 25 women only had normal piezogram drawing. Abnormalities similar to that of permanent hypertensive disease were observed in most cases. Dicrotic notch duration was significantly reduced and dicrotic notch pressure enhanced; in 34 women both of these abnormalities were present. In conclusion, among women previously hypertensive during pregnancy, even when blood pressure is returned to normal, abnormalities of arterial pulse wave may be present, suggesting that these women are prone to subsequent permanent hypertension.

  18. Literature review of cranial nerve injuries during carotid endarterectomy.

    Science.gov (United States)

    Sajid, M S; Vijaynagar, B; Singh, P; Hamilton, G

    2007-01-01

    In the recent prospective randomised trials on carotid endarterectomy (CEA), the incidence of cranial nerve injuries (CNI) are reported to be higher than in previously published studies. The objective of this study is to review the incidence of post CEA cranial nerve injury and to discover whether it has changed in the last 25 years after many innovations in vascular surgery. Generic terms including carotid endarterectomy, cranial nerve injuries, post CEA complications and cranial nerve deficit after neck surgery were used to search a variety of electronic databases. Based on selection criteria, decisions regarding inclusion and exclusion of primary studies were made. The incidence of CNI before and after 1995 was compared. We found 31 eligible studies from the literature. Patients who underwent CEA through any approach were included in the study. All patients had cranial nerves examined both before and after surgery. The total number of patients who had CEA before 1995 was 3521 with 10.6% CNI (352 patients) and after 1995, 7324 patients underwent CEA with 8.3% CNI (614 patients). Cranial nerves XII, X and VII were most commonly involved (rarely IX and XI). Statistical analysis showed that the incidence of CNI has decreased (X(2) = 5.89 + 0.74 = 6.63 => p-value = 0.0100). CNI is still a significant postoperative complication of carotid endarterectomy. Despite increasing use of CEA, the incidence of CNI has decreased probably because of increased awareness of the possibility of cranial nerve damage.

  19. Gender Differences in Treatment of Severe Carotid Stenosis After TIA

    Science.gov (United States)

    Poisson, Sharon N.; Johnston, S. Claiborne; Sidney, Stephen; Klingman, Jeffrey G.; Nguyen-Huynh, Mai N.

    2010-01-01

    Background and Purpose Gender differences in carotid endarterectomy (CEA) rates after transient ischemic attack (TIA) are not well studied, though some reports suggest that eligible men are more likely to have CEA than women after stroke. Methods We retrospectively identified all patients diagnosed with TIA and ≥70% carotid stenosis on ultrasound in 2003-2004 from 19 emergency departments. Medical records were abstracted for clinical data, 90-day follow-up events including stroke, cardiovascular events or death, CEA within 6 months, and post-operative 30-day outcomes. We assessed gender as a predictor of CEA and its complications, adjusting for demographic and clinical variables, as well as time to CEA between groups. Results Of 299 patients identified, 47% were women. Women were older with higher presenting SBP and less likely to smoke or to have CAD or diabetes. Fewer women (36.4%) had CEA than men (53.8%) (p=0.004). Reasons for withholding surgical treatment were similar in women and men, and there were no differences in follow-up stroke, CV event, postoperative complications or death. Time to CEA was also significantly delayed in women. Conclusions Women with severe carotid stenosis and recent TIA are less likely to undergo CEA than men, and surgeries are more delayed. PMID:20651270

  20. Complications and Follow-up after Unprotected Carotid Artery Stenting

    International Nuclear Information System (INIS)

    Hauth, Elke A.M.; Drescher, Robert; Jansen, Christian; Gissler, H. Martin; Schwarz, Michael; Forsting, Michael; Jaeger, Horst J.; Mathias, Klaus D.

    2006-01-01

    Purpose. This prospective study was undertaken to determine the success rate, complications, and outcome of carotid artery stenting (CAS) without the use of cerebral protection devices. Methods. During 12 months, 94 high-grade stenoses of the carotid artery in 91 consecutive patients were treated. Sixty-six (70%) of the stenoses were symptomatic and 28 (30%) were asymptomatic. Results. In all 94 carotid stenoses CAS was successfully performed. During the procedure and within the 30 days afterwards, there were 2 deaths and 3 major strokes in the 66 symptomatic patients, resulting in a combined death and stroke rate of 5 of 66 (7%). Only one of these complications, a major stroke, occurred during the procedure. In the 6-month follow-up, one additional major stroke occurred in a originally symptomatic patient resulting in a combined death and stroke rate of 6 of 66 (10%) for symptomatic patients at 6 months. No major complications occurred in asymptomatic patients during the procedure or in the 6-month follow-up period. At 6 months angiographic follow-up the restenosis rate with a degree of >50% was 3 of 49 (6%) and the rate with a degree of ≥70% was 1 of 49 (2%). Conclusions. Cerebral embolization during CAS is not the only cause of the stroke and death rate associated with the procedure. The use of cerebral protection devices during the procedure may therefore not prevent all major complications following CAS

  1. Quantification and visualization of carotid segmentation accuracy and precision using a 2D standardized carotid map

    International Nuclear Information System (INIS)

    Chiu, Bernard; Ukwatta, Eranga; Shavakh, Shadi; Fenster, Aaron

    2013-01-01

    This paper describes a framework for vascular image segmentation evaluation. Since the size of vessel wall and plaque burden is defined by the lumen and wall boundaries in vascular segmentation, these two boundaries should be considered as a pair in statistical evaluation of a segmentation algorithm. This work proposed statistical metrics to evaluate the difference of local vessel wall thickness (VWT) produced by manual and algorithm-based semi-automatic segmentation methods (ΔT) with the local segmentation standard deviation of the wall and lumen boundaries considered. ΔT was further approximately decomposed into the local wall and lumen boundary differences (ΔW and ΔL respectively) in order to provide information regarding which of the wall and lumen segmentation errors contribute more to the VWT difference. In this study, the lumen and wall boundaries in 3D carotid ultrasound images acquired for 21 subjects were each segmented five times manually and by a level-set segmentation algorithm. The (absolute) difference measures (i.e., ΔT, ΔW, ΔL and their absolute values) and the pooled local standard deviation of manually and algorithmically segmented wall and lumen boundaries were computed for each subject and represented in a 2D standardized map. The local accuracy and variability of the segmentation algorithm at each point can be quantified by the average of these metrics for the whole group of subjects and visualized on the 2D standardized map. Based on the results shown on the 2D standardized map, a variety of strategies, such as adding anchor points and adjusting weights of different forces in the algorithm, can be introduced to improve the accuracy and variability of the algorithm. (paper)

  2. The value and economic analysis of routine postoperative carotid duplex ultrasound surveillance after carotid endarterectomy.

    Science.gov (United States)

    AbuRahma, Ali F; Srivastava, Mohit; AbuRahma, Zachary; Jackson, Will; Mousa, Albeir; Stone, Patrick A; Dean, L Scott; Green, Jason

    2015-08-01

    Several studies have reported on the role of postoperative duplex ultrasound surveillance after carotid endarterectomy (CEA) with varying results. Most of these studies had a small sample size or did not analyze cost-effectiveness. We analyzed 489 of 501 CEA patients with patch closure. All patients had immediate postoperative duplex ultrasound examination and were routinely followed up both clinically and with duplex ultrasound at regular intervals of 1 month, 6 months, 12 months, and every 12 months thereafter. A Kaplan-Meier analysis was used to estimate the rate of ≥50% and ≥80% post-CEA restenosis over time and the time frame of progression from normal to ≥50% or ≥80% restenosis. The cost of post-CEA duplex surveillance was also estimated. Overall, 489 patients with a mean age of 68.5 years were analyzed. Ten of these had residual postoperative ≥50% stenosis, and 37 did not undergo a second duplex ultrasound examination and therefore were not included in the final analysis. The mean follow-up was 20.4 months (range, 1-63 months), with a mean number of duplex ultrasound examinations of 3.6 (range, 1-7). Eleven of 397 patients (2.8%) with a normal finding on immediate postoperative duplex ultrasound vs 4 of 45 (8.9%) with mild stenosis on immediate postoperative duplex ultrasound progressed to ≥50% restenosis (P = .055). Overall, 15 patients (3.1%) had ≥50% restenosis, 9 with 50% to duplex ultrasound), which equals $1,408,320, to detect only four patients with ≥80% to 99% restenosis who may have been potential candidates for reintervention. This study shows that the value of routine postoperative duplex ultrasound surveillance after CEA with patch closure may be limited, particularly if the finding on immediate postoperative duplex ultrasound is normal or shows minimal disease. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. Pseudoaneurysm of the Common Carotid Artery in an Infant due to Swallowed Fish Bone

    Directory of Open Access Journals (Sweden)

    Moulion Tapouh Jean Roger

    2015-01-01

    Full Text Available Carotid artery pseudoaneurysm is a rare condition, particularly in the paediatric population. Only about 30 cases of carotid artery aneurysms in infants have been published until now. This paper reports the case of a giant pseudoaneurysm of the left common carotid artery due to swallowed fish bone by an 8-year-old boy. This pseudoaneurysm was 5.5 cm transverse-diameter and resulted in severe respiratory distress. It was treated by resection and end-to-end anastomosis with satisfactory outcome after one-year follow-up. To the best of our knowledge, this is the largest carotid artery pseudoaneurysm ever described in children.

  4. Platelet activation, function, and reactivity in atherosclerotic carotid artery stenosis: a systematic review of the literature.

    LENUS (Irish Health Repository)

    Kinsella, J A

    2012-09-27

    An important proportion of transient ischemic attack or ischemic stroke is attributable to moderate or severe (50-99%) atherosclerotic carotid stenosis or occlusion. Platelet biomarkers have the potential to improve our understanding of the pathogenesis of vascular events in this patient population. A detailed systematic review was performed to collate all available data on ex vivo platelet activation and platelet function\\/reactivity in patients with carotid stenosis. Two hundred thirteen potentially relevant articles were initially identified; 26 manuscripts met criteria for inclusion in this systematic review. There was no consistent evidence of clinically informative data from urinary or soluble blood markers of platelet activation in patients with symptomatic moderate or severe carotid stenosis who might be considered suitable for carotid intervention. Data from flow cytometry studies revealed evidence of excessive platelet activation in patients in the early, sub-acute, or late phases after transient ischemic attack or stroke in association with moderate or severe carotid stenosis and in asymptomatic moderate or severe carotid stenosis compared with controls. Furthermore, pilot data suggest that platelet activation may be increased in recently symptomatic than in asymptomatic severe carotid stenosis. Excessive platelet activation and platelet hyperreactivity may play a role in the pathogenesis of first or subsequent transient ischemic attack or stroke in patients with moderate or severe carotid stenosis. Larger longitudinal studies assessing platelet activation status with flow cytometry and platelet function\\/reactivity in symptomatic vs. asymptomatic carotid stenosis are warranted to improve our understanding of the mechanisms responsible for transient ischemic attack or stroke.

  5. Asymptomatic carotid artery stenosis in patients with severe peripheral vascular diseases

    Directory of Open Access Journals (Sweden)

    Rasoul Mirsharifi

    2009-04-01

    Full Text Available

    • BACKGROUND: The prevalence of carotid artery stenosis (CAS in the  eneral population is not high enough to justify screening programs. This study was done to determine the prevalence of asymptomatic carotid artery stenosis (ACAS among patients with severe peripheral vascular disease (PVD.
    • METHODS: Between March 2005 and February 2006, 54 consecutive  atients with severe PVD admitted at a vascular surgery unit and underwent carotid duplex scanning in a prospective study. A  uestionnaire was used to collect data concerning known risk factors. Significant CAS was defined as a stenosis of 70% or greater.
    • RESULTS: The mean age was 62.5 years (51-72. Out of 54 patients, 2 (3.7% had an occluded internal carotid artery. Significant CAS was found in 9 (16.7% and its presence was correlated with diabetes, hypertension, hypercholesterolemia, hypertriglyceridemia, coronary artery disease, severity of symptoms, ankle-brachial index, and carotid bruit. On multivariate analysis, only hypercholesterolemia and carotid bruit seemed to have independent influence.
    • CONCLUSION: The prevalence of significant ACAS is higher among  atients with severe PVD. This patient population may indicate a  uitable subgroup for screening of ACAS, especially when hypercholesterolemia and carotid bruit are present.
    • KEYWORDS: Carotid artery stenosis, duplex ultrasound scanning, peripheral vascular disease, carotid endarterectomy,
    • cerebrovascular accident.

  6. A case of Behcet's disease with aneurysms of common carotid arteries and abdominal aorta

    International Nuclear Information System (INIS)

    Choo, Yeon Myung; Chang, Kee Hyun; Choi, Sung Jae

    1984-01-01

    One case of Behcet's disease with multiple aneurysms in both common carotid arteries and abdominal aorta is presented with brief review of the literatures. A 26-year-old woman had slowly enlarging pulsatile masses in both sides of neck and recurrent ulcerations in oral cavity and genitalia. One day prior to admission, aphasia, right facial nerve palsy and right hemiplegia suddenly developed. Brain CT showed acute infarction in left basal ganglia. Both Carotid Angiography and abdominal Aortography demonstrated multiple aneurysms in both common carotid arteries and abdominal aorta with organizing thrombi and thromboembolism of internal carotid artery

  7. Carotid duplex ultrasound and transcranial Doppler findings in commercial divers and pilots.

    Science.gov (United States)

    Dormanesh, Banafshe; Vosoughi, Kia; Akhoundi, Fahimeh H; Mehrpour, Masoud; Fereshtehnejad, Seyed-Mohammad; Esmaeili, Setareh; Sabet, Azin Shafiee

    2016-12-01

    The risky working environments of divers and pilots, and the possible role of extreme ambient pressure in carotid stenosis, make ischemic stroke an important occupational concern among these professionals. In this study, we aimed to evaluate the association of being exposed to hyperbaric or hypobaric conditions with carotid artery stenosis by comparing common carotid intima-media thickness (CCIMT) and blood flow velocities of cerebral arteries in divers and pilots using carotid duplex ultrasound (CDUS) and transcranial Doppler (TCD). CDUS and transtemporal TCD were performed in 29 divers, 36 pilots and 30 control participants. Medical history, blood pressure, lipid profile and blood sugar were recorded to control the previously well-known risk factors of atherosclerosis. Findings of the CDUS and TCD [including: CCIMT and blood flow velocities of internal carotid artery (ICA), common carotid artery (CCA), and middle cerebral artery (MCA)] of divers and pilots were compared with those of the control group using regression analysis models. Both right and left side CCIMT were significantly higher in divers (P < 0.05) and pilots (P < 0.05) in comparison with the control group. Carotid index [peak systolic velocity (PSV) of ICA/PSV of CCA) of divers and pilots were also higher than the control group. TCD findings were not significantly different between divers, pilots, and the control group. Increased CCIMT and carotid index in diver and pilot groups appear to be suggestive of accelerated atherosclerosis of carotid artery in these occupational groups.

  8. A Novel Method of Macropathologic and Arteriographic Examination of Carotid Specimens Obtained from Autopsy

    International Nuclear Information System (INIS)

    Schulte-Altedorneburg, Gernot; Droste, Dirk W.; Kollar, Jozsef; Hegedues, Csaba; Gomba, Szabolcs; Ringelstein, E. Bernd; Csiba, Laszlo

    2000-01-01

    Twenty carotid bifurcations were examined. During autopsy, carotid bifurcations were removed in toto. Unfixed carotids were ligated and cannulated for injection of an angiographic contrast medium followed by injection of a tissue-embedding medium at physiologic pressure and temperature. The carotid bifurcation was frozen and cut manually in 3-mm cross-sections. Photographs were then taken of every slice. Angiography, filling with tissue-embedding material, and sectioning were successful in all cases. In the macropathologic sections, the extent, configuration and location of atherosclerotic lesions could be identified

  9. ANTAGONISM OF PROGESTERONE RECEPTOR SUPPRESSES CAROTID BODY RESPONSES TO HYPOXIA AND NICOTINE IN RAT PUPS

    OpenAIRE

    JOSEPH, V.; NIANE, L. M.; BAIRAM, A.

    2012-01-01

    We tested the hypothesis that antagonism of progesterone receptor (PR) in newborn rats alters carotid body and respiratory responses to hypoxia and nicotinic receptor agonists. Rats were treated with the PR antagonist mifepristone (daily oral gavage 40 μg/g/d) or vehicle between post-natal days 3 and 15. In 11–14-day-old rats, we used in vitro carotid body/carotid sinus nerve preparation and whole body plethysmography to assess the carotid body and ventilatory responses to hypoxia (65 mmHg in...

  10. Emergency embolization in the treatment of intractable epistaxis resulted from carotid arterial disease

    International Nuclear Information System (INIS)

    Sun Zengtao; Liu Yanjun; Chao Baoting; Tang Jun; Liu Zuoqin; Chen Jie; Shang Jianqiang; Zhang Lei; Li Jijun

    2012-01-01

    Objective: To evaluate the clinical value of internal carotid artery occlusion in treatment of intractable epistaxis caused by carotid artery siphon traumatic lesions. Methods: A total of 37 patients with intractable epistaxis caused by traumatic carotid artery siphon pseudoaneurysm or carotid cavernous fistula were retrospectively analyzed. All the patients underwent embolization from October 1998 to June 2010, including 34 men and 3 women with the age ranged from 25 to 65 years and a average of 40 years. Only lesions were occluded in 12 cases without involving the internal carotid artery, while occlusions of internal carotid artery were performed in the rest 25 cases. Results: Thirty-six patients were cured without recurrent hemorrhage after embolization. Only 1 patient with carotid artery occlusion died 48 hours after operation. Conclusion: For patients with carotid arterial intractable epistaxis, if the elimination of the lesions is not applicable and the collateral circulation of Willis ring has a good compensation, the use of detachable balloon or coil occlusion of ipsilateral internal carotid artery is a quick and easy method to save patients' lives. (authors)

  11. Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis.

    Science.gov (United States)

    Mrówczyński, Wojciech; Mugnai, Damiano; de Valence, Sarra; Tille, Jean-Christophe; Khabiri, Ebrahim; Cikirikcioglu, Mustafa; Möller, Michael; Walpoth, Beat H

    2014-01-01

    There is a continuous search for shelf-ready small-caliber vascular prostheses with satisfactory early and late results. Biodegradable scaffolds, repopulated by recipient's cells regenerating a neovessel, can be a suitable option for adult and pediatric, urgent and elective cardiovascular procedures. This was a short-term experimental assessment of a new biodegradable vascular prosthesis for arterial replacement in the pig. Eleven pigs underwent bilateral carotid artery replacement with biodegradable electrospun poly-ε-caprolactone (PCL) nanofiber prostheses (internal diameter, 4 mm; length, 5 cm); or expanded polytetrafluoroethylene (ePTFE) prostheses as control. Perioperative anticoagulation was achieved with intravenous heparin (double baseline activated clotting time). Postoperatively, until conclusion of the study at 1 month, animals received aspirin and clopidogrel daily. Transit time flow was measured intraoperatively and at sacrifice. Doppler ultrasound (1 and 4 weeks) and a selective carotid angiography (4 weeks) were performed to assess patency. All explanted grafts were analyzed by histology, morphometry, and scanning electron microscopy in order to study graft-host interaction. Surgical handling and hemostasis of the new prostheses were excellent. Patency rate was 78% (7/9) for PCL grafts, compared with 67% (4/6) for ePTFE grafts. Transit time flow and Doppler ultrasound showed no significant changes in flow and velocity or diameter over time in both groups. Both prostheses showed no detectable in vivo compliance as compared with native carotid artery. Percent neoendothelialization was 86% for PCL and 58% for ePTFE grafts (P = .008). Neointima formation was equal in both grafts. More adventitial infiltration of macrophages, myofibroblasts, and capillaries was seen in PCL grafts with a milder foreign-body reaction when compared with ePTFE implants. Both grafts showed similar endoluminal thrombus formation. Biodegradable, electrospun PCL grafts showed

  12. Advantages of carotid endarterectomy under local anaesthesia with minimal cerebral monitoring: an experience of 45 cases

    International Nuclear Information System (INIS)

    Bajwa, S.P.; Jameel, M.; Masood, N.

    2014-01-01

    Objective: To evaluate the benefits, efficacy and safety of local cervical plexus block in the performance of carotid endarterectomy, in the absence of sophisticated cerebral perfusion monitoring. Place and Duration of Study: This study was carried out at Combined Military Hospital (CMH) Lahore, Pakistan from January 2012 to May 2013. Study Design: Quasi-experimental study. Patients and Methods: A total of 45 cases of ASA II and ASA III physical status were operated for carotid endarterectomy under local block of cervical plexus. After thorough preanaesthetic assessment, the patients physical conditions were optimized before surgery. Premedication was given with midazolam and sedated during operation with small doses of propofol. Local anaesthesia (LA) was completed by injecting bupivacaine in cervical plexuses 2, C3 and C4 areas. During operation vital signs and adequacy of cerebral perfusion were monitored by keeping the patient awake and making clinical neurological observations. Verbal contact was maintained with the patient. Breathing patterns and motor power were assessed in contralateral upper and lower limbs. Postoperatively patients were interviewed and analgesia during operation was assessed with visual analogue scale. Surgeon's satisfaction regarding intraoperative analgesia was also noted. Patients who required added sedation or local anesthetic agent were also noted. Average duration of surgery time was two hours and average stay of the patients in hospital was five days. Results: Out of 45 patients, 37 patients (82%) had smooth and comfortable anaesthesia and analgesia. In only 1 patient (2.2%) LA had to be converted into general anaesthesia (GA). In 3 cases (7%) LA was supplemented. One patient (2.2%) developed hoarseness and difficulty in breathing and 1 patient (2.2%) developed hemiparesis intra-operatively; while 1 patient (2.2%) developed hypotension in the immediate postoperative period. One patient (2.2%) developed haematoma at infiltration

  13. Surgical dissection of the internal carotid artery under flow control by proximal vessel clamping reduces embolic infarcts during carotid endarterectomy.

    Science.gov (United States)

    Yoshida, Kazumichi; Kurosaki, Yoshitaka; Funaki, Takeshi; Kikuchi, Takayuki; Ishii, Akira; Takahashi, Jun C; Takagi, Yasushi; Yamagata, Sen; Miyamoto, Susumu

    2014-01-01

    To evaluate the efficacy of flow control of the internal carotid artery (ICA) by the clamping of the common carotid artery, external carotid artery, and superior thyroid artery during surgical ICA dissection to reduce ischemic complications after carotid endarterectomy (CEA). Sixty-seven patients (59 men; age, 70.5 ± 6.2 years) who underwent CEA by the same surgeon were retrospectively studied. Both conventional CEA (n = 29) and flow-control CEA (n = 38) were performed with the patient under general anesthesia and with the use of somatosensory-evoked potential and near-infrared spectroscopy monitoring as a guide for selective shunting. The number of new postoperative infarcts was assessed with preoperative and postoperative diffusion-weighted images (DWIs) obtained within 3 days of surgery. In addition to surgical technique, the effects of the following factors on new infarcts also were examined: age, side of ICA stenosis, high-grade stenosis, symptoms, and application of shunting. New postoperative DWI lesions were observed in 7 of 67 patients (10.4%), and none of them was symptomatic. With respect to operative technique, the incidence rate of DWI spots was significantly lower in the flow-control group (2.6%) than in the conventional group (20.7%), odds ratio: 0.069; 95% confidence interval: 0.006-0.779; P = 0.031). On multiple logistic regression analysis, age, side of ICA stenosis, high-grade stenosis, symptoms, and the use of internal shunting did not have significant effects on new postoperative DWI lesions, whereas technique did have an effect. The proximal flow-control technique for CEA helps avoid embolic complications during surgical ICA dissection. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Carotid Stenting in Patients With High Risk Versus Standard Risk for Open Carotid Endarterectomy (REAL-1 Trial).

    Science.gov (United States)

    De Haro, Joaquin; Michel, Ignacio; Bleda, Silvia; Cañibano, Cristina; Acin, Francisco

    2017-07-15

    Carotid stenting (CAS) has been mainly offered to those patients considered at "high risk" for open carotid endarterectomy based on available data from large randomized clinical trials. However, several recent studies have called medical "high risk" into question for CAS indication. The REAL-1 trial evaluated the safety and perioperative and long-term effectiveness in patients with significant carotid artery stenosis with "high-risk" criteria treated with CAS and proximal protection device (MOMA) compared with those with standard surgical-risk features. This nonrandomized double-arm registry included 125 patients (40% symptomatic), 71 (56%) with "standard-risk" and 54 (44%) with "high-risk" criteria. The primary end point was the cumulative incidence of any major adverse event, a composite of stroke, myocardial infarction, and death within 30 days after the intervention or ipsilateral stroke after 30 days and up to 4 years. There was no significant difference in primary end point rate at 30 days between patients at "standard risk" and those with "high risk" (1.4% vs 1.9% respectively; hazard ratio for "standard risk" 1.1; 95% CI 0.8 to 1.2, p = 0.77) nor estimated 4-year rate of ipsilateral stroke (1.3% vs 1.8%; hazard ratio for "standard risk" 1.05, 95% CI 0.86 to 1.14, p = 0.9). In conclusion, 4-year postprocedure results demonstrated that CAS with proximal device (MOMA) is safe and effective for patients with and without "high-risk" for carotid endarterectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. The subpetrous carotid wall hematoma. A sign of spontaneous dissection of the internal carotid artery on non-enhanced computed tomography. A retrospective study

    International Nuclear Information System (INIS)

    Jensen-Kondering, U.; Univ. Hospital Schleswig-Holstein, Kiel; Huhndorf, M.; Madjidyar, J.; Jansen, O.

    2015-01-01

    Spontaneous dissection of the internal carotid artery (CAD) is an increasingly recognized cause for stroke especially in young and middle-aged patients. We hypothesized that non-enhanced cranial computed tomography (NECCT) can visualize the subpetrous carotid wall hematoma and thus enable identification of patients with CAD. We retrospectively reviewed patients with confirmed CAD (n=21) and a control group with ischemic symptoms but without CAD (n=42) who received NECCT at admission. Two independent neuroradiologists rated the presence and shape of SPH, density and diameter of the subpetrous internal carotid artery. Additionally, we correlated the shape of the subpetrous carotid wall hematoma with the grade of stenosis on subsequent angiographic imaging. The subpetrous carotid wall hematoma was present in 14 of 21 patients (Cohen's k = 0.67). Mean diameter was 6.95 ± 1.05 mm in dissected vessels and 5.71 ± 1.52 mm in the contralateral vessel (p<0.05). Mean difference in vessel density was 15.05 ± 8.01 HU (p<0.01). Median grade of stenosis was significantly higher in patients with a full moon- shaped (n=11) than crescent-shaped (n=3) subpetrous carotid wall hematoma (21% vs. 80%, p<0.05). Two-thirds of patients with CAD were correctly identified on NECCT. The extracranial carotid artery should be evaluated in patients with symptoms of cerebral ischemia.

  16. The subpetrous carotid wall hematoma. A sign of spontaneous dissection of the internal carotid artery on non-enhanced computed tomography. A retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Jensen-Kondering, U. [Univ. Hospital Schleswig-Holstein, Kiel (Germany). Dept. of Radiology and Neuroradiology; Univ. Hospital Schleswig-Holstein, Kiel (Germany). Dept. of Neurology; Huhndorf, M.; Madjidyar, J.; Jansen, O. [Univ. Hospital Schleswig-Holstein, Kiel (Germany). Dept. of Radiology and Neuroradiology

    2015-03-15

    Spontaneous dissection of the internal carotid artery (CAD) is an increasingly recognized cause for stroke especially in young and middle-aged patients. We hypothesized that non-enhanced cranial computed tomography (NECCT) can visualize the subpetrous carotid wall hematoma and thus enable identification of patients with CAD. We retrospectively reviewed patients with confirmed CAD (n=21) and a control group with ischemic symptoms but without CAD (n=42) who received NECCT at admission. Two independent neuroradiologists rated the presence and shape of SPH, density and diameter of the subpetrous internal carotid artery. Additionally, we correlated the shape of the subpetrous carotid wall hematoma with the grade of stenosis on subsequent angiographic imaging. The subpetrous carotid wall hematoma was present in 14 of 21 patients (Cohen's k = 0.67). Mean diameter was 6.95 ± 1.05 mm in dissected vessels and 5.71 ± 1.52 mm in the contralateral vessel (p<0.05). Mean difference in vessel density was 15.05 ± 8.01 HU (p<0.01). Median grade of stenosis was significantly higher in patients with a full moon- shaped (n=11) than crescent-shaped (n=3) subpetrous carotid wall hematoma (21% vs. 80%, p<0.05). Two-thirds of patients with CAD were correctly identified on NECCT. The extracranial carotid artery should be evaluated in patients with symptoms of cerebral ischemia.

  17. Leptomeningeal collateral vessels are a major risk factor for intracranial hemorrhage after carotid stenting in patients with carotid atherosclerotic plaque.

    Science.gov (United States)

    Lee, Kang Ji; Kwak, Hyo Sung; Chung, Gyung Ho; Song, Ji Soo; Hwang, Seung Bae

    2016-05-01

    To evaluate the relationship between leptomeningeal collaterals and intracranial hemorrhage (ICH) after carotid artery stenting (CAS). A retrospective study was undertaken of 228 patients (median age 75 years (range 44-90); 187 men and 41 women) who underwent CAS due to unilateral carotid atherosclerotic plaque from January 2009 to December 2013. Cerebral angiographic findings were classified into three patterns: type I, normal visualization of the anterior and middle cerebral arteries without leptomeningeal collaterals; type II, visualization of the middle cerebral artery only without leptomeningeal collaterals; and type III, visualization of leptomeningeal collateral flow. For all cerebral angiographic findings, 146 (64.0%) were type I, 61 (26.8%) were type II, and 21 (9.2%) were type III. Four patients (1.8%) died with fatal ICH after CAS and had type III angiographic findings (19%). The prevalence of ICH in patients with leptomeningeal collateral vessels was significantly higher than in patients without leptomeningeal collateral vessels (19% vs 0%, pcollateral vessels are a major risk factor for ICH after CAS in patients with carotid atherosclerotic plaque. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Long-term outcome of endovascular treatment versus medical care for carotid artery stenosis in patients not suitable for surgery and randomised in the Carotid and Vertebral Artery Transluminal Angioplasty study (CAVATAS).

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-01-01

    Optimal treatment of carotid stenosis in patients not suitable for surgery is unclear. The Carotid and Vertebral Artery Transluminal Angioplasty study contained a trial comparing medical and endovascular treatment in patients not suitable for surgery.

  19. Stent-induced flow disturbances in the ipsilateral external carotid artery following internal carotid artery stenting: a temporary cause of jaw claudication.

    Science.gov (United States)

    Giurgea, Georgiana-Aura; Haumer, Markus; Mlekusch, Irene; Sabeti-Sandor, Schila; Dick, Petra; Schillinger, Martin; Minar, Erich; Mlekusch, Wolfgang

    2017-07-01

    We hypothesize that stenting of the internal carotid artery can immediately impede blood flow to the external carotid artery by either plaque shift or stent coverage of the ostium, and thereby cause ischemic symptoms like ipsilateral jaw claudication. Thirty-three patients with high-grade asymptomatic stenosis of the internal carotid artery who underwent endovascular treatment were examined by ultrasound of the external carotid artery and performed an exercise test by chewing chewing gum synchronously to an electronic metronome for 3 min. Tests were performed before, the day after, and 1 week after the stenting procedure. Claudication time was defined as the timespan until occurrence of pain of the masseter muscle and/or chewing dyssynchrony to the metronome for more than 15 s. Ten patients with an isolated, atherosclerotic stenosis of the external carotid artery served as controls. A significantly reduced claudication time (in seconds) was recorded in patients who underwent carotid artery stenting compared to baseline values; median 89 (interquartile range, IQR, 57 to 124) vs. median 180 (IQR 153 to 180; p external carotid artery into faster or slower as 200 cm/sec, the effect was even accentuated. Stenting values showed improvement 1 week after but did not return to baseline levels. No respective changes were found in controls. Stenting of the internal carotid artery lead to ipsilateral flow deterioration at the external carotid artery resulting in temporary jaw claudication. This impairment attenuated over the time and was significantly reduced after 1 week.

  20. Extracranial Carotid Artery Stenting in Surgically High-Risk Patients Using the Carotid Wallstent Endoprosthesis:Midterm Clinical and Ultrasound Follow-Up Results

    International Nuclear Information System (INIS)

    Maleux, Geert; Bernaerts, Pauwel; Thijs, Vincent; Daenens, Kim; Vaninbroukx, Johan; Fourneau, Inge; Nevelsteen, Andre

    2003-01-01

    The purpose of this study was to evaluate the feasibility, safety and midterm outcome of elective implantation of the Carotid Wallstent (registered) in patients considered to be at high surgical risk. In a prospective study, 54 carotid artery stenoses in 51 patients were stented over a 24-month period. Three patients underwent bilateral carotid artery stenting. Institutional inclusion criteria for invasive treatment of carotid occlusive disease (carotid endarterectomy or carotid artery stenting) are patients presenting with a 70% or more symptomatic stenosis and those with an 80% or more asymptomatic stenosis having a life-expectancy of more than 1 year. All patients treated by carotid artery stenting were considered at high risk for carotid endarterectomy because of a hostile neck (17 patients-31.5%) or because of severe comorbidities (37 patients-68.5%). No cerebral protection device was used. Of the 54 lesions, 33 (61.1%) were symptomatic and 21 (38.8%) were asymptomatic. Follow-up was performed by physical examination and by duplex ultrasonography at 1 month, 6 months, 1 year and 2 years after the procedure. All 54 lesions could be stented successfully without periprocedural stroke. Advert events during follow-up (mean 13.9 ± 5.7 months) were non-stroke-related death in 6 patients (11.1%), minor stroke in 4 stented hemispheres(7.4%), transient ipsilateral facial pain in 1 patient (1.8%),infection of the stented surgical patch in 1 patient (1.8%) and asymptomatic in stent restenosis in 4 patients (7.4%). The percutaneous implantation of the Carotid Wallstent (registered) , even without cerebral protection device, appears to be a safe procedure with acceptable clinical and ultrasonographic follow-up results in patients at high surgical risk. But some late adverse events such as ipsilateral recurrence of non-disabling (minor) stroke or in stent restenosis still remain real challenging problems

  1. Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent

    International Nuclear Information System (INIS)

    Stasek, Josef; Lojik, Miroslav; Bis, Josef; Horak, David; Dusek, Jaroslav; Brtko, Miroslav; Polansky, Pavel; Babu, Anush; Vojacek, Jan

    2009-01-01

    We report an original method of transcatheter closure of an arteriovenous fistula using the combination of an Amplatzer PDA occluder and a carotid stent. The fistula was between the left carotid artery and the brachiocephalic vein. The patient had significant left-to-right shunt and was highly symptomatic. Due to the large orifice and pseudoaneurysmatic enlargement of the fistula, we had to use a large Amplatzer PDA occluder and the protruding part of the PDA device disk had to be covered with a carotid stent. The fistula was completely closed. The patient stopped having symptoms and, 2 years after the procedure, the effect persists.

  2. Validation of a basic neurosonology laboratory for detecting cervical carotid artery stenosis.

    Science.gov (United States)

    de la Cruz Cosme, C; Dawid Milner, M S; Ojeda Burgos, G; Gallardo Tur, A; Márquez Martínez, M; Segura, T

    2017-03-24

    Most of the cases of ischaemic stroke in our setting are of atherothrombotic origin. Detecting intracranial and cervical carotid artery stenosis in patients with ischaemic stroke is therefore essential. Ultrasonography has become the tool of choice for diagnosing carotid artery stenosis because it is both readily accessibility and reliable. However, use of this technique must be validated in each laboratory. The purpose of this study is to validate Doppler ultrasound in our laboratory as a means of detecting severe carotid artery stenosis. We conducted an observational descriptive study to evaluate diagnostic tests. The results from transcranial and cervical carotid Doppler ultrasound scans conducted by neurologists were compared to those from carotid duplex scans performed by radiologists in patients diagnosed with stroke. Arteriography was considered the gold standard (MR angiography, CT angiography, or conventional arteriography). Our sample included 228 patients. Transcranial and cervical carotid Doppler ultrasound showed a sensitivity of 95% and specificity of 100% for detection of carotid artery stenosis > 70%, whereas carotid duplex displayed a sensitivity of 87% and a specificity of 94%. Transcranial carotid Doppler ultrasound achieved a sensitivity of 78% and a specificity of 98% for detection of intracranial stenosis. Doppler ultrasound in our neurosonology laboratory was found to be a useful diagnostic tool for detecting cervical carotid artery stenosis and demonstrated superiority to carotid duplex despite the lack of B-mode. Furthermore, this technique was found to be useful for detecting intracranial stenosis. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Duplex ultrasound: A diagnostic tool for carotid stenosis management in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Yogan Kisten

    2013-07-01

    Full Text Available Background: Diabetic patients are at increased risk of developing cardiac events and stroke, and prevention of diabetes mellitus is therefore desirable. Marked geographical and ethnic variation in the prevalence of diabetes caused by urbanisation, demographic and epidemiological transitions has rendered this one of the major non-communicable diseases in South Africa. Duplex ultrasound (DUS plays an important role in primary health care in early detection of carotid atherosclerotic disease and the degree of carotid stenosis present. It is a reliable, cost-effective and non-invasive diagnostic tool. The purpose of this study was to determine the role of ultrasound in carotid stenosis management in type 2 diabetes mellitus (T2DM. Objectives: To determine the prevalence of carotid stenosis in a selected T2DM population using DUS and to correlate these findings with other predisposing atherosclerotic risk factors. Methods: The study setting was at an academic hospital in the Western Cape using carotid DUS reports of 103 diabetic subjects ≥ 35 years old. Predisposing risk factors were correlated with degree of carotid stenosis present. Data were analysed using the Fischer exact test, Chisquare and Student t-test. Results: Carotid DUS reports of 63 out of 103 T2DM patients revealed no evidence of a carotid stenosis, thereby lowering the risk profile. Forty patients were identified as having carotidstenosis; 22 symptomatic patients had a > 70% carotid stenosis which warranted surgicalintervention. A greater prevalence of stenosis in the Caucasian group, in both the male (p =0.0411 and female (p = 0.0458 cohorts, was noted. The overall trend suggested a relationship between T2DM and lifestyle, and a statistically significant relationship (p = 0.0063 between smoking and carotid stenosis was observed. Conclusion: T2DM and predisposing atherosclerotic risk factors significantly increased thepossibility of carotid stenosis development.

  4. Hybrid treatment of tandem, common carotid/innominate artery and ipsilateral carotid bifurcation stenoses by simultaneous, retrograde proximal stenting and eversion carotid endarterectomy: Preliminary results of a case series.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Pasqua, Rocco; Frezzotti, Francesca; Palumbo, Piergaspare; Macrina, Francesco; Calio', Francesco

    2018-04-01

    Tandem stenoses of the internal carotid artery (ICA) and proximal, ipsilateral common carotid artery (CCA) or innominate artery can be treated with a hybrid approach, combining conventional carotid endarterectomy (CEA) and retrograde stenting of the proximal stenosis, through surgical exposure of the carotid bifurcation. The purpose of this study was to evaluate the results of combining eversion CEA with retrograde CCA/innominate artery stenting. From January 2015 to July 2017, 7 patients, 6 men of a mean age of 72 years (range 59-83 years) underwent simultaneous, retrograde stenting of the proximal CCA/innominate artery and an eversion CEA of the ipsilateral ICA, through surgical exposure of the carotid bifurcation, for severe tandem stenoses. The proximal stenosis involved the left proximal CCA in 4 patients, the proximal innominate artery in 2 patients and the right CCA in one patient. The procedure was performed under general anesthesia in a conventional operating room equipped with a mobile C-arm. A covered, balloon expandable stent was deployed over the proximal stenosis via a 6-F sheath directly introduced into the proximal CCA through the obliquely transected carotid bulb. After removing the sheath, debris were flushed through the carotid bulb and eversion CEA completed the procedure. Study endpoints were: postoperative stroke/mortality rate, cardiac mortality and morbidity, peripheral nerve injury, cervical hematoma, overall late survival, freedom from ipsilateral stroke and patency of arterial reconstruction. No postoperative mortality or neurologic morbidity was observed in any patient. Cervical hematomas and peripheral nerve injuries were likewise absent. At a mean follow-up of 18 months, all the patients were alive, free from neurologic events of new onset and free from restenosis. Combined proximal stenting and eversion CEA for tandem lesions seems a valid treatment, with the advantages of eversion CEA over other techniques of carotid bifurcation

  5. Controllable growth and optical properties of InP and InP/InAs nanostructures on the sidewalls of GaAs nanowires

    International Nuclear Information System (INIS)

    Yan, Xin; Zhang, Xia; Li, Junshuai; Cui, Jiangong; Ren, Xiaomin

    2014-01-01

    The growth and optical properties of InP and InP/InAs nanostructures on GaAs nanowires are investigated. InP quantum well and quantum dots (QDs) are formed on the sidewalls of GaAs nanowires successively with increasing the deposition time of InP. The GaAs/InP nanowire heterostructure exhibits a type-II band alignment. The wavelength of the InP quantum well is in the range of 857–892 nm at 77 K, which means that the quantum well is nearly fully strained. The InP quantum dot, which has a bow-shaped cross section, exhibits dislocation-free pure zinc blende structure. Stranski-Krastanow InAs quantum dots are subsequently formed on the GaAs/InP nanowire core-shell structure. The InAs quantum dots are distributed over the middle part of the nanowire, indicating that the In atoms contributing to the quantum dots mainly come from the vapor rather than the substrate. The longest emission wavelength obtained from the InAs QDs is 1039 nm at 77 K. The linewidth is as narrow as 46.3 meV, which is much narrower than those on planar InP substrates and wurtzite InP nanowires, suggesting high-crystal-quality, phase-purity, and size-uniformity of quantum dots

  6. Installation of carotid stent in a group of patient of high surgical risk for carotid endarterectomy - Preliminary experience

    International Nuclear Information System (INIS)

    Gomez Hoyos, Juan Fernando; Celis Mejia, Jorge Ignacio; Yepes Sanchez, Carlos Jaime; Duque Botero, Julieta

    1998-01-01

    Carotid endarterectomy success in symptomatic or asymptomatic patients has been demonstrated in NASCET and ACAS studies. Although, some patients with carotid stenosis have frequently other pathologies which increase risk in endarterectomy or other surgeries like coronary bypass and aortic-iliac reconstruction. Other patients have lesions such as post surgical restenosis, fibromuscular dysplasia, radiation stenosis or tumoral disease, or stenotic lesions above jaw angle. The main objectives of this work are: to demonstrate, upon the results, that multidisciplinary management of 1 patient with symptomatic or not carotid critical stenosis. Let to select, with strict clinical criteria, those doing well with endovascular therapy. To evaluate implantation technique, peryoperatory morbidity and mortality and permeability time with implanted dispositive. In this study, the preliminary experience of the neurovascular group at the Clinica Cardiovascular Santa Maria in Medellin is presented, during an 18 months period of multidisciplinary management in 15 patients, 7 men and 8 women with critical carotid stenosis. 18 procedures were performed and 21 stents were implanted. The mean age was 66 years. All patients had 70% or greater stenotic lesions, and 93.3% were symptomatic. Twelve (80%) had contraindications to perform surgery. one asymptomatic patient (6.6%) was referred with procedure indications and two (13.3%) requested the stent implantation as their own election. the patient with fibromuscular dysplasia was treated with Wallstent (number 4) and the remaining patients were treated with Palmaz stent. technical success was 100%, 3 patients had pacemaker rhythm, one patient (6.6%) presented extra-pyramidal syndrome which responded to medical treatment in 24 hours. one patient developed right side hemiparesis with total recovery in 4 hours. One patient with a critical left carotid artery stenosis presented right side hemiparesis (3/5) and aphasia, nine months later paresis

  7. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  8. Evaluation of the carotid artery stenosis based on minimization of mechanical energy loss of the blood flow.

    Science.gov (United States)

    Sia, Sheau Fung; Zhao, Xihai; Li, Rui; Zhang, Yu; Chong, Winston; He, Le; Chen, Yu

    2016-11-01

    Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss. Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss. We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.

  9. Effects of ilexonin a on IL-6 and M-CSF following ballon angioplasty in rabbit common carotid artery

    International Nuclear Information System (INIS)

    Zhao Lihua; Li Zhangwei; Yang Chuang; Jiang Yaqiu

    2008-01-01

    Objective: To observe the effects of ilexonin A(IA) on IL-6 and M-CSF following ballon angioplasty in rabbit common carotide artery to provide experimental basis for percutaneous coronary interventions. Mehtods: 30 Japanese rabbits were fed with high cholesterol food for 4 weeks. Then they were divided into three groups randomly. Each group had ten rabbits. 1) Control group: the incision was sew directly after right carotide artery of the rabbit was seeked. 2) Balloon dilation group: the proximal of the carotide artery was cuted, the ballon was delivered and distended, after it was drawn repeatly, the incision was closed. 3) IA therapy group: operation was the same to the balloon dilation group, then IA was administered in vein. All of them were fed with high cholesterol diet for 4 weeks and the blood samples were collected 1 d before the operation and 1 d, 1,2,4 weeks after the operation. The serum IL-6 and M-CSF levels were determined with radioimmunoassay. The pathological changes of injuried artery were observed. Results: 1) The IL-6 level in balloon dilation group was higher than that in IA therapy group after the operation (P<0.05), and came back later to preoperation level. 2) Though the M-CSF level in IA therapy group was increased, but it was lower than that in dilation group (P<0.05). 3) The pathological results demonstrated that the artery endothelial in control group was smooth and no foam cell in sight. In bolloon dilation group, the endangium was thickened, the vascular smooth muscle cells proliferated, there were many foam cells and the lumen was constrictive. In IA therapy group, the number of foam cells reduced, the constrictive degree of lumen was alleviated. Conclusion: IA can redece the levels of serum IL-6 and M-CSF and inhibit the proliferation of vascular smooth muscle cells following ballon angioplasty. (authors)

  10. Doppler examination of the periorbital arteries adds valuable hemodynamic information in carotid artery disease

    DEFF Research Database (Denmark)

    Sillesen, H; Schroeder, T; Steenberg, H J

    1987-01-01

    The periorbital flow direction and internal carotid artery (ICA) angiogram were compared to the ICA pressure gradient across the stenosis and the distal ICA pressure in 51 patients subjected to carotid endarterectomy. All 17 patients with inverted periorbital flow had stenoses exceeding 50%. The ...... collaterals and, Patients with 50% stenosis or more and insufficient collaterals....

  11. Autopsy findings in carotid arterial rupture following radiotherapy of head and neck advanced carcinoma

    International Nuclear Information System (INIS)

    Satake, Bunsuke; Matsuura, Shizumu; Sakaino, Kouji; Maehara, Yasunobu

    1989-01-01

    The influence of radiotherapy in advanced head and neck cancer was investigated by autopsy of head and neck patients who had had carotid artery rupture. Twenty-five cases of head and neck cancer revealed carotid artery rupture among the 255 head and neck cases autopsied from 1972 to 1985. The rate of carotid artery rupture in hypopharyngeal cancer was 8/32 (25%); in oral cancer 8/55 (14.5%), and in other cancers 9/165 (5.4%). In localization of ruptured arteries there were 9 cases of common carotid artery, 14 cases of external carotid artery, one case of internal carotid artery, and one unknown. These cases were irradiated using more than 70 Gy. The following reasons for carotid artery rupture were suspected: 1. There was a tumor with deep ulceration and necrosis near the vessel. 2. The wall of the artery had radiation angitis. 3. The artery wall was necrotic because of invasion by the tumor. 4. Thrombosis developed with ensuant rupture of the artery. Radiotherapy for advanced cancer of the head and neck is necessary to control pain and as palliative treatment, but to avoid rupture of the carotid artery, pain clinic techniques and chemotherapy as palliative treatment for this kinds of terminal condition should also be considered. (author)

  12. Blood flows in the maxillocarotid anastomoses and internal carotid artery of conscious dogs.

    Science.gov (United States)

    Lee, M C; Reid, I A; Ramsay, D J

    1986-06-01

    Although the external carotid artery is known to contribute to the cerebral blood flow in anesthetized dogs, quantitative information on the anastomoses and their role in conscious dogs is lacking. This study was carried out to determine blood flows in these anastomoses and the internal carotid artery, and also to examine the functional significance of the anastomoses in conscious dogs. Fifteen-micron radioactive microspheres were injected into common and external carotid arteries of four conscious dogs through chronically implanted catheters. Blood flows were determined by the reference sample method and by comparing microsphere distributions in the brain and the masseter muscle. Blood flows were estimated to be 140 +/- 32, 7.7 +/- 1.4, and 3.3 +/- 1.1 ml/minute (mean +/- SD) in the common carotid artery, internal carotid artery, and anastomoses on each side, respectively. Additional evidence indicated that the anastomotic flow so determined was primarily the flow in the anastomotic artery. Humoral responses to angiotensin II infusions were also studied in conscious dogs. External carotid angiotensin increased plasma 11-hydroxycorticosteroid concentration (used as an index of ACTH secretion) but did not increase plasma vasopressin concentration to the same extent as common carotid infusion. Therefore, the external carotid artery is functionally important in perfusing the brain in conscious dogs.

  13. Cognitive functioning and quality of life of atherosclerotic patients following carotid endarterectomy.

    NARCIS (Netherlands)

    Bossema, E.R.; Brand, A.N.; Moll, F.L.; Ackerstaff, R.G.A.; Doornen, L.J.P. van

    2002-01-01

    Background: Carotid endarterectomy (CEA) is a surgical procedure to remove atherosclerotic plaque from one of the carotid arteries in patients with severe stenosis. The purpose is to prevent future cerebral ischemic attacks. Whether patients, in addition, improve in cognitive functions and quality

  14. Separate origins of the internal and external carotid arteries depicted on CT angiography: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kwang Ho [Dept. of horacic and Cardiovascular Surgery, Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of); Beak, Hye Jin; Jung, Hyun Kyung [Dept. of Radiology, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2015-08-15

    Agenesis of the common carotid artery (CCA) is a rare congenital anomaly. We presented a rare case of unilateral congenital absence of the right CCA with separate origins of the ipsilateral internal and external carotid arteries from the brachiocephalic artery. Further, we reviewed the embryological mechanism and clinical importance of this anomaly.

  15. A historical prospective cohort study of carotid artery stenosis after radiotherapy for head and neck malignancies

    International Nuclear Information System (INIS)

    Brown, Paul D.; Foote, Robert L.; McLaughlin, Mark P.; Halyard, Michele Y.; Ballman, Karla V.; Collie, A. Craig; Miller, Robert C.; Flemming, Kelly D.; Hallett, John W.

    2005-01-01

    Purpose: To determine carotid artery stenosis incidence after radiotherapy for head-and-neck neoplasms. Methods and Materials: This historical prospective cohort study comprised 44 head-and-neck cancer survivors who received unilateral neck radiotherapy between 1974 and 1999. They underwent bilateral carotid duplex ultrasonography to detect carotid artery stenosis. Results: The incidence of significant carotid stenosis (8 of 44 [18%]) in the irradiated neck was higher than that in the contralateral unirradiated neck (3 of 44 [7%]), although this difference was not statistically significant (p = 0.13). The rate of significant carotid stenosis events increased as the time after radiotherapy increased. The risk of ipsilateral carotid artery stenosis was higher in patients who had undergone a neck dissection vs. those who had not. Patients with significant ipsilateral stenosis also tended to be older than those without significant stenosis. No other patient or treatment variables correlated with risk of carotid artery stenosis. Conclusions: For long-term survivors after neck dissection and irradiation, especially those who are symptomatic, ultrasonographic carotid artery screening should be considered

  16. Plaque inflammation and unstable morphology are associated with early stroke recurrence in symptomatic carotid stenosis.

    LENUS (Irish Health Repository)

    Marnane, Michael

    2014-03-01

    Although symptomatic carotid stenosis is associated with 3-fold increased risk of early stroke recurrence, the pathophysiologic mechanisms of high early stroke risk have not been established. We aimed to investigate the relationship between early stroke recurrence after initial symptoms and histological features of plaque inflammation and instability in resected carotid plaque.

  17. Preoperative embolization for juvenile nasopharyngeal angiofibroma. Usefulness of IADSA and problems of external carotid ligation

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, Ryuichi; Nakagawa, Nobuo; Kohrogi, Yukinori; Izunaga, Hiroshi; Bussaka, Hiromasa; Miyawaki, Masayuki; Takahashi, Mutsumasa; Ikawa, Tsutomu; Ishikawa, Takashi (Kumamoto Univ. (Japan). School of Medicine)

    1984-10-01

    Three male cases of juvenile nasopharyngeal angiofibroma are presented. Satisfactory results were obtained by performing preoperative embolization combined with intraarterial digital subtraction angiography (IADSA) in two of them. The other case had undergone external carotid ligation. Usefulness of IADSA in performing preoperative embolization for this disease and problems of external carotid ligation are discussed.

  18. The clinical use of objective quantification of flow disturbance in carotid artery disease

    DEFF Research Database (Denmark)

    Sillesen, H; Bitsch, K; Steenberg, H J

    1987-01-01

    In order to assess the accuracy of objective quantification of carotid flow disturbance, 147 carotid arteries were examined with continuous wave (CW) Doppler technique. The systolic spectral broadening index (SBI), determined as (maximum-mean)/maximum frequency, was calculated from the power...

  19. Characterization of plaque in the internal carotid artery. Comparison neuroradiological findings with pathological findings

    International Nuclear Information System (INIS)

    Nishikawa, Misao; Nishio, Akimasa; Takami, Toshihiro; Goto, Takeo; Ueda, Makiko; Hara, Mitsuhiro

    2006-01-01

    We evaluate the morphology of the carotid plaque using echogram, CT scan and MRI and compare those neuroradiological findings with histological findings of the plaque. We evaluated 14 cases operated with carotid endoarterectomy for carotid stenosis. We estimated the findings of the echogram, enhanced CT scan and black blood MRI (BB MRI), in comparison with the histological findings of the carotid plaque. Echogram, enhanced CT scan and MRI clearly demonstrated the plaque in cervical carotid stenosis. In most cases, echograms could show the plaque, but in some cases could not due to the back shadow caused by plaque calcification. Enhanced CT scan clearly demonstrated the calcification and the neovasculization in plaque. BB MRI clearly showed the carotid plaque. Low-intensity lesions in T1 and T2 weighted images showed hard and fibrous plaque. High-intensity lesions in T1 and T2 weighted images showed soft plaque with lipoprotein and/or hemorrhage. This study demonstrates the potential of a systemic approach to atherosclerotic plaque with enhanced CT scan and BB MRI compared with histological findings of the carotid plaque. These estimations elucidate the growth mechanism of carotid plaque. (author)

  20. ANTAGONISM OF PROGESTERONE RECEPTOR SUPPRESSES CAROTID BODY RESPONSES TO HYPOXIA AND NICOTINE IN RAT PUPS

    Science.gov (United States)

    JOSEPH, V.; NIANE, L. M.; BAIRAM, A.

    2013-01-01

    We tested the hypothesis that antagonism of progesterone receptor (PR) in newborn rats alters carotid body and respiratory responses to hypoxia and nicotinic receptor agonists. Rats were treated with the PR antagonist mifepristone (daily oral gavage 40 μg/g/d) or vehicle between post-natal days 3 and 15. In 11–14-day-old rats, we used in vitro carotid body/carotid sinus nerve preparation and whole body plethysmography to assess the carotid body and ventilatory responses to hypoxia (65 mmHg in vitro, 10% O2 in vivo) and to nicotinic receptor agonists (as an excitatory modulator of carotid body activity—nicotine 100 μM for in vitro studies, and epibatidine 5 μg/kg, i.p., which mainly acts on peripheral nicotinic receptors, for in vivo studies). The carotid body responses to hypoxia and nicotine were drastically reduced by mifepristone. Compared with vehicle, mifepristone-treated rats had a reduced body weight. The ventilatory response to epibatidine was attenuated; however, the hypoxic ventilatory response was similar between vehicle and mifepristone-treated pups. Immunohistochemical staining revealed that mifepristone treatment did not change carotid body morphology. We conclude that PR activity is a critical factor ensuring proper carotid body function in newborn rats. PMID:22326965