WorldWideScience

Sample records for experimental apparatus technique

  1. Informationization nuclear apparatus communication technique

    International Nuclear Information System (INIS)

    Yu Tiqi; Fang Zongliang; Wen Qilin

    2006-01-01

    The paper explains the request of communication ability in nuclear technique application area. Based on the actuality of nuclear apparatus communication ability, and mainly combining with the development of communication technique, the authors analyzes the application trend of communication technique applying in nuclear apparatus, for the apparatus and system needing communication ability, they need selecting suitable communication means to make them accomplish the task immediately and effectively. (authors)

  2. Centrifuge Techniques and Apparatus for Transport Experiments in Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Earl D. Mattson; Carl D. Paler; Robert W. Smith; Markus Flury

    2010-06-01

    This paper describes experimental approaches and apparatus that we have developed to study solute and colloid transport in porous media using Idaho National Laboratory's 2-m radius centrifuge. The ex-perimental techniques include water flux scaling with applied acceleration at the top of the column and sub-atmospheric pressure control at the column base, automation of data collection, and remote experimental con-trol over the internet. These apparatus include a constant displacement piston pump, a custom designed liquid fraction collector based on switching valve technology, and modified moisture monitoring equipment. Suc-cessful development of these experimental techniques and equipment is illustrated through application to transport of a conservative tracer through unsaturated sand column, with centrifugal acceleration up to 40 gs. Development of such experimental equipment that can withstand high accelerations enhances the centrifuge technique to conduct highly controlled unsaturated solute/colloid transport experiments and allows in-flight liquid sample collection of the effluent.

  3. Development of an experimental apparatus for nucleate boiling analysis

    International Nuclear Information System (INIS)

    Castro, A.J.A. de.

    1984-01-01

    An experimental apparatus is developed for the study of the parameters that affect nucleate boiling. The experimental set up is tested for nucleate boiling in an annular test section with subcooled water flow. The following parameters are analysed: pressure, fluid velocity and the fluid temperature at the test section entrance. The performance of the experimental apparatus is analysed by the results and by the problems raised by the operation of the setup. (Author) [pt

  4. Development of an experimental apparatus for boiling analysis

    International Nuclear Information System (INIS)

    Castro, A.J.A. de.

    1984-04-01

    The nucleate boiling is the most interesting boiling regime for practical appliccations, including nuclear reactor engineering. such regime is characterized by very high heat transfer rates with only small surface superheating. An experimental apparatus is developed for studying parameters which affect nucleate boiling. The following parameters are analysed: pressure, fluid velocity and the fluid temperature at the test section entrance. The performance of experimental apparatus is analysed by results and by problems raised by the oeration of setup. (Author) [pt

  5. Secrets and lies: "selective openness" in the apparatus of animal experimentation.

    Science.gov (United States)

    Holmberg, Tora; Ideland, Malin

    2012-04-01

    Researchers and other (human) actors within the apparatus of animal experimentation find themselves in a tight corner. They rely on public acceptance to promote their legitimacy and to receive funding. At the same time, those working with animal experimentation take risks by going public, fearing that the public will misunderstand their work and animal rights activists may threaten them. The dilemma that emerges between openness and secrecy is fairly prevalent in scientific culture as a whole, but the apparatus of animal experimentation presents specific patterns of technologies of secrets. The aim of the paper is to describe and analyse the meanings of secrets and openness in contemporary animal experimentation. We suggest that these secrets--or "selective openness"--can be viewed as grease in the apparatus of animal experimentation, as a unifying ingredient that permits maintenance of status quo in human/animal relations and preserves existing institutional public/ science relations.

  6. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  7. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  8. The speed of progress in the apparatus handling technique in rhythmic gymnastics

    Directory of Open Access Journals (Sweden)

    Moskovljević Lidija

    2013-01-01

    Full Text Available Specificity of rhythmic gymnastics as a sport and as a teaching device are apparatus routines. Considering lack of researches, the aim of our study was to determine ages of maturity when the development in apparatus routines performance is greater. Development in essential rope, hoop and ball routine performance was examined two times per year, through four years experimental period. The evaluation is carried out three-member RG-expert committee on a scale of 1 to 10. A total of twenty-seven competitors, examined at ages seven to fourteen, participate in this study. Based on data, we can notice that speed of progress in apparatus handling technique was not equal during observing maturity period. There was not significant development in most of examined routines between seven to nine years of ages. Significant development in this period has been achieved only in two rope routines (Vij1 i Vij2R and one ball routine to (Lop2R. From eleven to twelve years of ages, significant development has been achieved for most of routines, except basic running with rope (Vij1 and hoop routine performed with weaker arm (Obr2L. At 12 to 13 years of ages, development of routines performance has not been statistically significant.

  9. Outline of an experimental apparatus for the study on the advanced voloxidation process

    International Nuclear Information System (INIS)

    Uchiyama, Gunzo; Sugikawa, Susumu; Maeda, Mitsuru; Tsujino, Takeshi; Torikai, Seishi; Kitamura, Masafumi; Yamazaki, Kazunobu.

    1990-02-01

    The experimental apparatus (VULCAN, the capacity; 2 kg-UO 2 /batch) was constructed to study on the advanced voloxidation process, which was proposed to reduce amount of tritium released from fuel reprocessing facilities. Using this equipment, a process study was conducted on behaviors of oxidation-reduction of simulated fuels and of release of tritium, and on confinement function of rotary seal of the reactor. An outline of the experimental apparatus is described. (author)

  10. Simulation test of PIUS-type reactor with large scale experimental apparatus

    International Nuclear Information System (INIS)

    Tamaki, M.; Tsuji, Y.; Ito, T.; Tasaka, K.; Kukita, Yutaka

    1995-01-01

    A large scale experimental apparatus for simulating the PIUS-type reactor has been constructed keeping the volumetric scaling ratio to the realistic reactor model. Fundamental experiments such as a steady state operation and a pump trip simulation were performed. Experimental results were compared with those obtained by the small scale apparatus in JAERI. We have already reported the effectiveness of the feedback control for the primary loop pump speed (PI control) for the stable operation. In this paper this feedback system is modified and the PID control is introduced. This new system worked well for the operation of the PIUS-type reactor even in a rapid transient condition. (author)

  11. Gas-phase hydrosilylation of cyclohexene in an experimental radiation-chemical accelerator apparatus

    International Nuclear Information System (INIS)

    Pecherkin, A.S.; Sidorov, V.I.; Chernyshev, E.A.

    1992-01-01

    A process for the synthesis of methylcyclohexyldichlorosilane (a basic monomer for the production of organosilicon photoresists) has been investigated and perfected on an experimental apparatus with an ELV-2 electron accelerator; this synthesis involves gas-phase radiation-induced hydrosilylation of cyclohexene by methyldichlorosilane. Basic characteristics of the yield of the desired product under static conditions were determined. With the help of experiments on the synthesis of methylcyclohexyldichlorosilane in a flow- through mode, the technical features of the process of radiation-chemical hydrosilylation of cyclohexene on an accelerator apparatus were determined and studied, the optimal conditions for the synthesis were determined, and an experimental batch of the desired product was produced

  12. Experimental device for obtaining calibration factor for the total count technique

    International Nuclear Information System (INIS)

    Gonçalves, Eduardo R.; Braz, Delson; Brandão, Luís Eduardo B.

    2017-01-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  13. Experimental device for obtaining calibration factor for the total count technique

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Eduardo R.; Braz, Delson [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Brandão, Luís Eduardo B. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Divisao de Reatores

    2017-07-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  14. Experimental apparatus with full optical access for combustion experiments with laminar flames from a single circular nozzle at elevated pressures.

    Science.gov (United States)

    Joo, Peter H; Gao, Jinlong; Li, Zhongshan; Aldén, Marcus

    2015-03-01

    The design and features of a high pressure chamber and burner that is suitable for combustion experiments at elevated pressures are presented. The high pressure combustion apparatus utilizes a high pressure burner that is comprised of a chamber burner module and an easily accessible interchangeable burner module to add to its flexibility. The burner is well suited to study both premixed and non-premixed flames. The optical access to the chamber is provided through four viewports for direct visual observations and optical-based diagnostic techniques. Auxiliary features include numerous access ports and electrical connections and as a result, the combustion apparatus is also suitable to work with plasmas and liquid fuels. Images of methane flames at elevated pressures up to 25 atm and preliminary results of optical-based measurements demonstrate the suitability of the high pressure experimental apparatus for combustion experiments.

  15. Design and experimental results of the 1-T Bitter Electromagnet Testing Apparatus (BETA)

    Science.gov (United States)

    Bates, E. M.; Birmingham, W. J.; Romero-Talamás, C. A.

    2018-05-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) technical prototype of the 10 T Adjustable Long Pulsed High-Field Apparatus. BETA's final design specifications are highlighted in this paper which include electromagnetic, thermal, and stress analyses. We discuss here the design and fabrication of BETA's core, vessel, cooling, and electrical subsystems. The electrical system of BETA is composed of a scalable solid-state DC breaker circuit. Experimental results display the stable operation of BETA at 1 T. These results are compared to both analytical design and finite element calculations. Experimental results validate analytical magnet designing methods developed at the Dusty Plasma Laboratory. The theoretical steady state maxima and the limits of BETA's design are explored in this paper.

  16. Instrumentation, computer software and experimental techniques used in low-frequency internal friction studies at WNRE

    International Nuclear Information System (INIS)

    Sprugmann, K.W.; Ritchie, I.G.

    1980-04-01

    A detailed and comprehensive account of the equipment, computer programs and experimental methods developed at the Whiteshell Nuclear Research Estalbishment for the study of low-frequency internal friction is presented. Part 1 describes the mechanical apparatus, electronic instrumentation and computer software, while Part II describes in detail the laboratory techniques and various types of experiments performed together with data reduction and analysis. Experimental procedures for the study of internal friction as a function of temperature, strain amplitude or time are described. Computer control of these experiments using the free-decay technique is outlined. In addition, a pendulum constant-amplitude drive system is described. (auth)

  17. Construction apparatus for thermochemical hydrogen production process

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, S.; Nakajima, H.; Higashi, S.; Onuki, K.; Akino, S.S.N. [Japan Atomic Energy Research Inst., Ibaraki-ken (Japan). Nuclear Heat Utilization Engineering Lab

    2001-06-01

    Studies have been carried out at the Japan Atomic Energy Research Institute (JAERI) on hydrogen production through thermochemical processes such as water-splitting. These studies are classified with iodine-sulphur cycle studies using heat from high temperature gas-cooled reactors. An experimental apparatus was constructed with fluorine resin, glass and quartz. It can produce hydrogen at a rate of 50 litres per hour. Electricity provides the heat required for the operation. The closed chemical process requires special control techniques. The process flow diagram for the apparatus was designed based on the results of previous studies including one where hydrogen production was successfully achieved at a rate of one liter per hour for 48 hours. Experimental operations under atmospheric pressure will be carried out for the next four years to develop the process. The data will be used in the next research and development programs aimed at designing a bench-scale apparatus. 7 refs., 1 tab., 8 figs.

  18. The ALPHA antihydrogen trapping apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Amole, C. [Department of Physics and Astronomy, York University, Toronto ON Canada, M3J 1P3 (Canada); Andresen, G.B. [Department of Physics and Astronomy, Aarhus University, DK-8000 Aarhus C (Denmark); Ashkezari, M.D. [Department of Physics, Simon Fraser University, Burnaby, BC Canada, V5A 1S6 (Canada); Baquero-Ruiz, M. [Department of Physics, University of California at Berkeley, Berkeley, CA 94720-7300 (United States); Bertsche, W. [Department of Physics, College of Science, Swansea University, Swansea SA2 8PP (United Kingdom); School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); The Cockcroft Institute, Warrington WA4 4AD (United Kingdom); Bowe, P.D. [Department of Physics and Astronomy, Aarhus University, DK-8000 Aarhus C (Denmark); Butler, E. [Physics Department, CERN, CH-1211 Geneva 23 (Switzerland); Capra, A. [Department of Physics and Astronomy, York University, Toronto ON Canada, M3J 1P3 (Canada); Carpenter, P.T. [Department of Physics, Auburn University, Auburn, AL 36849-5311 (United States); Cesar, C.L. [Instituto de Física, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-972 (Brazil); Chapman, S. [Department of Physics, University of California at Berkeley, Berkeley, CA 94720-7300 (United States); Charlton, M.; Deller, A.; Eriksson, S. [Department of Physics, College of Science, Swansea University, Swansea SA2 8PP (United Kingdom); Escallier, J. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Fajans, J. [Department of Physics, University of California at Berkeley, Berkeley, CA 94720-7300 (United States); Friesen, T. [Department of Physics and Astronomy, University of Calgary, Calgary AB, Canada, T2N 1N4 (Canada); Fujiwara, M.C.; Gill, D.R. [TRIUMF, 4004 Wesbrook Mall, Vancouver BC, Canada V6T 2A3 (Canada); Gutierrez, A. [Department of Physics and Astronomy, University of British Columbia, Vancouver BC, Canada V6T 1Z4 (Canada); and others

    2014-01-21

    The ALPHA collaboration, based at CERN, has recently succeeded in confining cold antihydrogen atoms in a magnetic minimum neutral atom trap and has performed the first study of a resonant transition of the anti-atoms. The ALPHA apparatus will be described herein, with emphasis on the structural aspects, diagnostic methods and techniques that have enabled antihydrogen trapping and experimentation to be achieved.

  19. A new experimental apparatus for emissivity measurements of steel and the application of multi-wavelength thermometry to continuous casting billets

    Science.gov (United States)

    Wang, Peng; Hu, Zhenwei; Xie, Zhi; Yan, Ming

    2018-05-01

    An experimental apparatus has been designed for measuring the emissivity of a steel surface in both vacuum and oxidation atmosphere. The sample is heated with the method of electromagnetic induction in order to ensure the temperature uniformity. The radiance emitted from a sample is measured using a fiber-optic Fourier transform infrared spectrometer. Using this unique apparatus, we investigated the spectral (2-6 μm) and directional (0°-86°) emissivity of stainless steel 304 with different degrees of surface oxidation at temperatures ranging from 800 to 1100 °C. The experimental results show that the emissivity increases slightly with increasing temperature, which accords with the Hagen-Rubens relation. The emissivity increases rapidly at the initial stage of oxidation, but gradually reaches to a constant value after 20 min. In addition, the directional emissivity has a maximum value at the measuring angle of about 75°. The maximum uncertainty of emissivity is only 3.0% over all the measuring ranges, indicating that this experimental apparatus has a high reliability. In order to measure the surface temperature of casting billets based on multi-wavelength thermometry, the bivariate emissivity function with the two variables, wavelength and temperature, is determined. Temperature measurement results based on our technique are compared with those from common dual-wavelength radiation thermometry. Our approach reduces the measured temperature fluctuation from ±20.7 °C to ±2.8 °C and reflects the temperature variation with the changes of production parameters in real time.

  20. Recent Progress in Electrical Insulation Techniques for HTS Power Apparatus

    Science.gov (United States)

    Hayakawa, Naoki; Kojima, Hiroki; Hanai, Masahiro; Okubo, Hitoshi

    This paper describes the electrical insulation techniques at cryogenic temperatures, i.e. Cryodielectrics, for HTS power apparatus, e.g. HTS power transmission cables, transformers, fault current limiters and SMES. Breakdown and partial discharge characteristics are discussed for different electrical insulation configurations of LN2, sub-cooled LN2, solid, vacuum and their composite insulation systems. Dynamic and static insulation performances with and without taking account of quench in HTS materials are also introduced.

  1. Modified swelling pressure apparatus using vapor pressure technique for compacted bentonite

    International Nuclear Information System (INIS)

    Nishimura, Tomoyoshi

    2012-01-01

    Document available in extended abstract form only. bentonite. The compacted bentonite is found in unsaturated conditions before applying of swelling due to absorption. The behaviour of compacted bentonite is not consistent with the principle and concepts of classical, saturated soil mechanics. An unsaturated soil theoretical framework using soil water characteristic curve has been fairly established over the past several decades. The soil-water characteristic curve is a relationship between soil moisture and soil suction obtained by the axis translation technique, vapor pressure technique or osmotic suction control which is a key feature in unsaturated soil mechanics. The soil-water characteristic curve can be used for prediction of the shear strength, volume change and hydraulic conductivity. Cui et al. 2002 indicated soil-water characteristic curve of expansive clay soil in high soil suction ranges using osmotic suction technique. Tripathy et al. 2010 described the soil-water characteristic curve both using the axis translation technique and vapor pressure technique in the entire soil suction ranges. Nishimura and Koseki 2011 measured suction of bentonite applied high soil suction due vapor pressure using a chilled mirror dew point potentiometer (WP4-T of DECAGON Device). The bentonite with gravimetric water content of 18 % indicated soil suction of 2.8 MPa at least. It is predicted that suction efforts to swelling pressure and shear strength of unsaturated compacted bentonite. This study focuses on the influence of suction on both swelling pressure and shear strength of compacted bentonite. The soil-water characteristic curve (SWCC) tests were conducted for compacted bentonite using both axis-translation technique and vapor pressure technique. The SWCC had a range from 0 kPa to 296 MPa in suction. The compacted bentonite having two different soil suctions were prepared for swelling pressure tests. Newly swelling pressure testing apparatus was developed in order

  2. JT-60 negative ion beam NBI apparatus. Present state of its construction and initial experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Kuriyama, Masaaki [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1997-02-01

    The NBI (Neutral Beam Injection) apparatus used for negative ion at first in the world, has an aim to actually prove heating and electric current drive with high density plasma at the JT-60 and to constitute physical and technical bases for selection and design of heating apparatus of ITER (International Thermal Nuclear Fusion Experimental Reactor). Construction of 500 KeV negative ion NBI apparatus for the JT-60 started to operate on 1993 was completed at March, 1996. On the way, at a preliminary test on forming and acceleration of the negative ion beam using a portion of this apparatus, 400 KeV and 13.5 A/D of the highest deuterium negative ion beam acceleration in the world was obtained successfully, which gave a bright forecasting of the plasma heating and electric current drive experiment using the negative ion NBI apparatus. After March, 1996, some plans to begin beam incident experiment at the JT-60 using the negative ion NBI apparatus and to execute the heating and electric current drive experiment at the JT-60 under intending increase of beam output are progressed. (G.K.)

  3. Experimental apparatus for furfural production from logging waste products by pyrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Karlivans, V.; Krumina, Z.; Zemite, G.; Kulkevics, A.; Pugulis, J.; Zav' yalov, V.A.; Ievins, I.; Daugavietis, M.; Tsirlin, Yu.A.; Fedotova, S.A.

    1981-01-01

    An experimental apparatus was developed for the manufacture of furfural (I) -containing condensates by pyrolysis of wood waste in the presence of 1.8% H2SO4. The highest yield of I (7.6%) was obtained when the waste was pyrolyzed at 210 degrees. The heat required for the manufacture of I-containing condensates is 712 kcal/kg. Commercial I isolated from the condensates meets the standards of GOST 10337-71.

  4. BETA (Bitter Electromagnet Testing Apparatus)

    Science.gov (United States)

    Bates, Evan M.; Birmingham, William J.; Rivera, William F.; Romero-Talamas, Carlos A.

    2017-10-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) prototype of the 10-T Adjustable Long Pulse High-Field Apparatus (ALPHA). These water-cooled resistive magnets use high DC currents to produce strong uniform magnetic fields. Presented here is the successful completion of the BETA project and experimental results validating analytical magnet designing methods developed at the Dusty Plasma Laboratory (DPL). BETA's final design specifications will be highlighted which include electromagnetic, thermal and stress analyses. The magnet core design will be explained which include: Bitter Arcs, helix starters, and clamping annuli. The final version of the magnet's vessel and cooling system are also presented, as well as the electrical system of BETA, which is composed of a unique solid-state breaker circuit. Experimental results presented will show the operation of BETA at 1 T. The results are compared to both analytical design methods and finite element analysis calculations. We also explore the steady state maximums and theoretical limits of BETA's design. The completion of BETA validates the design and manufacturing techniques that will be used in the succeeding magnet, ALPHA.

  5. Gamma Radiation from Fission Fragments Experimental Apparatus-Mass Spectrum Resolution

    Energy Technology Data Exchange (ETDEWEB)

    Higbie, Jack

    1969-08-15

    The gamma-radiation from fission fragments was studied as a function of the fragment mass. The mass was determined from the fragment energies using solid state detectors. The mass resolution which can be achieved by this method is treated in detail. The average initial fragment mass and the initial mass resolution is calculated as a function of the measured (apparent) mass yield for three different thicknesses of the fissile material deposit. This treatment gives a clear indication of those factors most important for good mass resolution work. A detailed description of the experimental apparatus is given in the appendices.

  6. Experimental comparison of particle interaction measurement techniques using optical traps

    International Nuclear Information System (INIS)

    Koehler, Timothy P.; Grillet, Anne Mary; Brotherton, Christopher M.; Molecke, Ryan A.

    2008-01-01

    Optical tweezers has become a powerful and common tool for sensitive determination of electrostatic interactions between colloidal particles. Recently, two techniques, 'blinking' tweezers and direct force measurements, have become increasingly prevalent in investigations of inter-particle potentials. The 'blinking' tweezers method acquires physical statistics of particle trajectories to determine drift velocities, diffusion coefficients, and ultimately colloidal forces as a function of the center-center separation of two particles. Direct force measurements monitor the position of a particle relative to the center of an optical trap as the separation distance between two continuously trapped particles is gradually decreased. As the particles near each other, the displacement from the trap center for each particle increases proportional to the inter-particle force. Although commonly employed in the investigation of interactions of colloidal particles, there exists no direct comparison of these experimental methods in the literature. In this study, an experimental apparatus was developed capable of performing both methods and is used to quantify electrostatic potentials between particles in several particle/solvent systems. Comparisons are drawn between the experiments conducted using the two measurement techniques, theory, and existing literature. Forces are quantified on the femto-Newton scale and results agree well with literature values

  7. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1975-01-01

    Apparatus and methods for verifying the validity of data derived at least in part by neutron logging of earth formations, and, where indicated, for affording neutron diffusion-corrected values of such data, are disclosed. (WHK)

  8. Experimental apparatus to investigate interactions of low energy ions with solid surfaces, 1

    International Nuclear Information System (INIS)

    Tsukakoshi, Osamu; Narusawa, Tadashi; Mizuno, Masayasu; Sone, Kazuho; Ohtsuka, Hidewo.

    1975-12-01

    Experimental apparatus to study the surface phenomena has been designed, which is intended to solve the vacuum wall problems in future thermonuclear fusion reactors and large experimental tokamak devices. An ion source and the beam transport optics are provided for bombarding solid target surface with an ion beam of energy from 0.1 to 6 keV. Measuring instruments include an ion energy analyser, a quadrupole mass spectrometer, an Auger electron spectrometer, an electro-micro-balance, a neutral particle energy spectrometer and its calibration system. Pumping system consists of oil-free ultrahigh vacuum pumps. Various kinds of experiments will be carried out by using the apparatus: 1) sputtering by low energy ion bombardment, 2) re-emission of the incident particles during and after ion bombardment, 3) release of adsorbed and occluded gases in the solids by ion bombardment, and 4) backscattering of fast ions. The combinations of measuring instruments for each experiment and their relative positions in the vacuum chamber are described through detailed drawings. The fundamental aspect in design of the ion beam transport optics for a low energy ion beam which can no longer neglect the space charge effect is also discussed. (auth.)

  9. Measuring the Biodegradability of Plastic Polymers in Olive-Mill Waste Compost with an Experimental Apparatus

    Directory of Open Access Journals (Sweden)

    Francesco Castellani

    2016-01-01

    Full Text Available The use of biodegradable polymers is spreading in agriculture to replace those materials derived from petroleum, thus reducing the environmental concerns. However, to issue a significant assessment, biodegradation rate must be measured in case-specific standardized conditions. In accordance with ISO 14855-1, we designed and used an experimental apparatus to evaluate the biodegradation rate of three biopolymers based on renewable resources, two poly(ε-caprolactone (PCL composites, and a compatibilized polylactic acid and polybutyrate (PLA/PBAT blend. Biodegradation tests were carried out under composting condition using mature olive-mill waste (OMW compost as inoculum. Carbon dioxide emissions were automatically recorded by infrared gas detectors and also trapped in saturated Ba(OH2 solution and evaluated via a standard titration method to check the results. Some of the samples reached more than 80% biodegradation in less than 20 days. Both the experimental apparatus and the OMW compost showed to be suitable for the cases studied.

  10. Thermal test of the insulation structure for LH 2 tank by using the large experimental apparatus

    Science.gov (United States)

    Kamiya, S.; Onishi, K.; Konshima, N.; Nishigaki, K.

    Conceptual designs of large mass LH 2 (liquid hydrogen) storage systems, whose capacity is 50,000 m3, have been studied in the Japanese hydrogen project, World Energy Network (WE-NET) [K. Fukuda, in: WE-NET Hydrogen Energy Symposium, 1999, P1-P41]. This study has concluded that their thermal insulation structures for the huge LH 2 tanks should be developed. Their actual insulation structures comprise not only the insulation material but also reinforced members and joints. To evaluate their thermal performance correctly, a large test specimen including reinforced members and joints will be necessary. After verifying the thermal performance of a developed large experimental apparatus [S. Kamiya, Cryogenics 40 (1) (2000) 35] for measuring the thermal conductance of various insulation structures, we tested two specimens, a vacuum multilayer insulation (MLI) with a glass fiber reinforced plastic (GFRP) support and a vacuum solid insulation (microtherm ®) with joints. The thermal background test for verifying the thermal design of the experimental apparatus showed that the background heat leak is 0.1 W, small enough to satisfy apparatus performance requirement. The thermal conductance measurements of specimens also showed that thermal heat fluxes of MLI with a GFRP support and microtherm ® are 8 and 5.4 W/m2, respectively.

  11. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1978-01-01

    This invention relates in general to neutron logging of earth formations, and in particular, to novel apparatus and procedures for determining the validity, or reliability, of data derived at least in part by logging neutron characteristics of earth formations and, if desired, for affording verifiably accurate indications of such data

  12. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1974-01-01

    This invention relates in general to neutron logging of earth formations, and in particular, to novel apparatus and procedures for determining the validity, or reliability, of data derived at least in part by logging neutron characteristics of earth formations and, if desired, for affording verifiably accurate indications of such data. (author)

  13. Torque application technique and apparatus

    Science.gov (United States)

    Pineault, Raymond P.

    1993-11-01

    A tool which produces a measured torque is coupled to a bolt head or nut, located in a relatively inaccessible area, by apparatus which includes a wrench member affixed to an adaptor. The wrench member is sized and shaped to engage the fastener to be operated upon and the adaptor has a tubular construction with a tool engaging socket at one end. The adaptor is provided with an elongated slot which accommodates any wires which may pass through the fastener.

  14. Experimentally measuring a quantum state by the Heisenberg exchange interaction in a single apparatus

    International Nuclear Information System (INIS)

    Peng Xinhua; Du Jiangfeng; Suter, D.

    2005-01-01

    Full text: Quantum information processing requires the effective measurement of quantum states. An important method, called quantum state tomography, needs measuring a complete set of observables on the measured system to determine its unknown quantum state ρ. The measurement involves certain noncommuting observables as a result of Bohr's complementarity. Very recently, Allahverdyan et al. proposed a new method in which the unknown quantum state r is determined by measuring a set of commuting observables in the price of a controlled interaction with an auxiliary system. If both systems S and A are spins, their z components (σ z ) can be chosen to measure after some specific Heisenberg exchange interaction. We study in detail a general Heisenberg XYZ model for a two-qubit system and present two classes of special Heisenberg interactions which can serve as the controlled interaction in Allahverdyan's scheme when the state of the auxiliary system A is initially completely disordered. Using the nuclear magnetic resonance techniques, the measurement scheme in a single apparatus has been experimentally demonstrated by designing the quantum circuit to simulate the Heisenberg exchange interaction. (author)

  15. Strongly correlated systems experimental techniques

    CERN Document Server

    Mancini, Ferdinando

    2015-01-01

    The continuous evolution and development of experimental techniques is at the basis of any fundamental achievement in modern physics. Strongly correlated systems (SCS), more than any other, need to be investigated through the greatest variety of experimental techniques in order to unveil and crosscheck the numerous and puzzling anomalous behaviors characterizing them. The study of SCS fostered the improvement of many old experimental techniques, but also the advent of many new ones just invented in order to analyze the complex behaviors of these systems. Many novel materials, with functional properties emerging from macroscopic quantum behaviors at the frontier of modern research in physics, chemistry and materials science, belong to this class of systems. The volume presents a representative collection of the modern experimental techniques specifically tailored for the analysis of strongly correlated systems. Any technique is presented in great detail by its own inventor or by one of the world-wide recognize...

  16. Experimental apparatus for teaching electrostatic topics: the electroscope with field-effect transistor

    Directory of Open Access Journals (Sweden)

    Thiago Alves de Sá Muniz Sampaio

    2017-05-01

    Full Text Available Regular school labs lack experiments that can properly identify many of the phenomena present in the electrostatic study. This paper proposes the implementation of a new kind of simple experimental apparatus for teaching topics in this area of physics, consisting of an electroscope kind that uses the field-effect transistor for detecting electric charges coming from electrified bodies. An explanation is given on the principles that makes this type of transistor an effective device due to its high sensitivity to electrostatic fields, as well as an analysis of the usefulness of this project for viewing many peculiar phenomena, such as polarization and induction. Based on this, we propose some simple activities that can be done in the classroom to involve students in the initial subject of electrostatics. We expect that this form of teaching along with experimental and explanatory approach of the phenomena in the classroom can bring to students a better learning of these concepts, demonstrating the utility of experimentation on teaching electrostatics.

  17. Experimental technique of neutron reflection

    International Nuclear Information System (INIS)

    Chen Bo; Huang Chaoqiang; Li Xinxi

    2006-12-01

    It is presented that the classifications, structures and components of neutron reflectometer (NR), as well s functions and parameters of each components, detailed characters of NR facility 'PRN-2M'. Based on the practical experiments, the basic experimental techniques, the measurement and the related experimental settings are described, including the choice of experimental conditions, adjustments of polarized neutron beam line, basic experimental technique and approach of measurement. The above can be an instruction for NR experiments and a reference for NR construction. (authors)

  18. The experimental apparatus for synchrotron radiation Moessbauer spectroscopy of BL11 in SPring-8

    International Nuclear Information System (INIS)

    Mitsui, T.; Kitao, S.; Zhang, X.W.; Marushita, M.; Seto, M.

    2001-01-01

    Synchrotron radiation Moessbauer spectroscopy (time spectrum of nuclear forward scattering and nuclear resonant inelastic scattering) enables us to study both the electronic state and lattice dynamics of a target material. Furthermore, the excellent properties of synchrotron radiation (polarization, pulse, small beam size) promise us the unique studies for material science. In order to progress in these studies, some experimental apparatuses were installed in BL11XU of SPring-8

  19. Mechanical design of experimental apparatus for FIREX cryo-target cooling

    Science.gov (United States)

    Iwamoto, A.; Norimatsu, T.; Nakai, M.; Sakagami, H.; Fujioka, S.; Shiraga, H.; Azechi, H.

    2016-05-01

    Mechanical design of an experimental apparatus for FIREX cryo-target cooling is described. Gaseous helium (GHe) sealing system at a cryogenic environment is an important issue for laser fusion experiments. The dedicated loading system was designed for a metal gasket. We take U-TIGHTSEAL® (Usui Kokusai Sangyo Kaisha. Ltd.) with an indium plated copper jacket as an example. According to its specification, a linear load of 110 N/m along its circumference is the optimum compression; however a lower load would still maintain helium (He) leak below the required level. Its sealing performance was investigated systematically. Our system demanded 27 N/mm of the load to keep He leak tightness in a cryogenic environment. Once leak tightness was obtained, it could be reduced to 9.5 N/mm.

  20. Experimental apparatus and analysis technique for studying the low Reynolds number hydrodynamic behavior of water-borne particulates

    International Nuclear Information System (INIS)

    Chase, R.R.P.; Tisue, G.T.

    1975-01-01

    A unique laboratory apparatus has been designed, constructed, and tested for analyzing the low Reynolds number hydrodynamic behavior of water-borne particulates. The system consists of an isothermal sedimentation chamber, collimated light sources, photographic optics, and monitoring devices. This apparatus is capable of providing dynamic information on water-borne particulates in the size range 2 μm to 700 μm, while simulating a realistic environment. Because of its flexibility, the equipment is being used to determine the kinematic behavior of gravitationally unstable organic mineral aggregates. The importance of organic mineral aggregates has been well established during the past decade. This material is believed to be a potential food source for marine biota at the lowest levels of the food chain. Organic mineral aggregates are also known to concentrate trace elements and other toxic substances and may be part of the control mechanism by which elemental concentrations are maintained in the water column. The benthic fluid mud layer and deep pelagic nepholoid layer consist, in part, of these sediments. Subsea petroleum reserves are thought to be the result of biogeochemical cycling of the organic-mineral complex. Undoubtedly, a fundamental study of these aggregates would be of value to many research interests

  1. Specifications for surface reaction analysis apparatus

    International Nuclear Information System (INIS)

    Teraoka, Yuden; Yoshigoe, Akitaka

    2001-03-01

    A surface reaction analysis apparatus was installed at the JAERI soft x-ray beamline in the SPring-8 as an experimental end-station for the study of surface chemistry. The apparatus is devoted to the study concerning the influence of translational kinetic energy of incident molecules to chemical reactions on solid surfaces with gas molecules. In order to achieve the research purpose, reactive molecular scattering experiments and photoemission spectroscopic measurements using synchrotron radiation are performed in that apparatus via a supersonic molecular beam generator, an electron energy analyzer and a quadrupole mass analyzer. The detail specifications for the apparatus are described in this report. (author)

  2. Experimental studies of a zeeman-tuned xenon laser differential absorption apparatus.

    Science.gov (United States)

    Linford, G J

    1973-06-01

    A Zeeman-tuned cw xenon laser differential absorption device is described. The xenon laser was tuned by axial magnetic fields up to 5500 G generated by an unusually large water-cooled dc solenoid. Xenon laser lines at 3.37 micro, 3.51 micro, and 3.99 micro were tuned over ranges of 6 A, 6 A, and 11 A, respectively. To date, this apparatus has been used principally to study the details of formaldehyde absorption lines lying near the 3 .508-micro xenon laser transition. These experiments revealed that the observed absorption spectrum of formaldehyde exhibits a sufficiently unique spectral structure that the present technique may readily be used to measure relative concentrations of formaldehyde in samples of polluted air.

  3. Method and apparatus for optimizing operation of a power generating plant using artificial intelligence techniques

    Science.gov (United States)

    Wroblewski, David [Mentor, OH; Katrompas, Alexander M [Concord, OH; Parikh, Neel J [Richmond Heights, OH

    2009-09-01

    A method and apparatus for optimizing the operation of a power generating plant using artificial intelligence techniques. One or more decisions D are determined for at least one consecutive time increment, where at least one of the decisions D is associated with a discrete variable for the operation of a power plant device in the power generating plant. In an illustrated embodiment, the power plant device is a soot cleaning device associated with a boiler.

  4. Assembly and calibration of a new experimental apparatus for production and utilization of capture gamma rays

    International Nuclear Information System (INIS)

    Semmler, R.

    1993-01-01

    A new experimental apparatus has been mounted at the tangential beam tube B H 4/12 of the IPEN IEA-R1 (2 MW) reactor, for production and utilization of capture gamma rays. In this type of experiment, monochromatic gamma radiation, with energy resolution of about 10 eV, is produced by thermal neutron capture in several materials placed near the reactor core. By changing the target material it was possible to obtain up to 30 gamma lines in the 5 to 11 MeV energy range and so, the present experimental arrangement may be considered as an excellent gamma ray source for photonuclear reactions studies in low excitation energies. (author)

  5. The development of human factors experimental evaluation techniques -The development of human factors technologies-

    International Nuclear Information System (INIS)

    Sim, Bong Shick; Oh, In Seok; Cha, Kyeong Ho; Lee, Hyun Chul

    1994-04-01

    In the 2nd year of the research project for the development of human factors evaluation techniques, we first defined the experimental target systems by the comparison study of the advanced control rooms proposed by foreign countries in order to make the experiment feasible and realistic for the 10 experimental items selected in the first year of the project. Then we have decided to confine our research on the big board overview panel and operator workstations. Following the development of selection criteria for our research interest, we have identified the design variables which may influence the performance of the operator by the functional analysis. The experimental variables which will be used for the evaluation of the proposed items are then defined by the relational analysis between evaluation items and design variables and they are classified by the characteristics of the measurement data. The functional requirements of ITF are developed to accommodate the necessary functions for carrying out the 10 evaluation items. The functional requirements for each sub-system of ITF have been developed with the experimental paradigm of APTEA. Finally we have reviewed the compact nuclear simulator (CNS) at KAERI from the point of view of jyman factors guidelines/principles and proposed the two possible layouts for the experimental apparatus for the evaluation of display alternative and operational procedure. (Author)

  6. Schlenk Techniques for Anionic Polymerization

    KAUST Repository

    Ratkanthwar, Kedar

    2015-09-01

    Anionic polymerization-high vacuum techniques (HVTs) are doubtlessly the most prominent and reliable experimental tools to prepare polymer samples with well-defined and, in many cases, complex macromolecular architectures. Due to the high demands for time and skilled technical personnel, HVTs are currently used in only a few research laboratories worldwide. Instead, most researchers in this filed are attracted to more facile Schlenk techniques. The basic principle of this technique followed in all laboratories is substantially the same, i.e. the use of alternate vacuum and inert gas atmosphere in glass apparatus for the purification/charging of monomer, solvents, additives, and for the manipulation of air-sensitive compounds such as alkyl metal initiators, organometallic or organic catalysts. However, it is executed quite differently in each research group in terms of the structure of Schlenk apparatus (manifolds, connections, purification/storage flasks, reactors, etc.), the use of small supplementary devices (soft tubing, cannulas, stopcocks, etc.) and experimental procedures. The operational methods are partly purpose-oriented while also featured by a high flexibility, which makes it impossible to describe in detail each specific one. In this chapter we will briefly exemplify the application of Schlenk techniques for anionic polymerization by describing the performance of a few experiments from our own work.

  7. Experimental Techniques

    International Nuclear Information System (INIS)

    Fournier, D.; Serin, L.

    1995-01-01

    Experimental techniques to be used in the new generation of high energy physics are presented. The emphasis is put on the new ATLAS and CMS detectors for the CERN LHC. For the most important elements of these detectors, a description of the underlying physics processes is given, sometimes with reference to comparable detectors used in the past. Some comparative global performances of the two detectors are also given, with reference to benchmark physics processes (detection of the Higgs boson in various mass regions, etc). (author)

  8. Design of an experimental apparatus for measurement of the surface tension of metastable fluids

    Science.gov (United States)

    Vinš, V.; Hrubý, J.; Hykl, J.; Blaha, J.; Šmíd, B.

    2013-04-01

    A unique experimental apparatus for measurement of the surface tension of aqueous mixtures has been designed, manufactured, and tested in our laboratory. The novelty of the setup is that it allows measurement of surface tension by two different methods: a modified capillary elevation method in a long vertical capillary tube and a method inspired by the approach of Hacker (National Advisory Committee for Aeronautics, Technical Note 2510, 1-20, 1951), i.e. in a short horizontal capillary tube. Functionality of all main components of the apparatus, e.g., glass chamber with the capillary tube, temperature control unit consisting of two thermostatic baths with special valves for rapid temperature jumps, helium distribution setup allowing pressure variation above the liquid meniscus inside the capillary tube, has been successfully tested. Preliminary results for the surface tension of the stable and metastable supercooled water measured by the capillary elevation method at atmospheric pressure are provided. The surface tension of water measured at temperatures between +26 °C and -11 °C is in good agreement with the extrapolated IAPWS correlation (IAPWS Release on Surface Tension of Ordinary Water Substance, September 1994); however it disagrees with data by Hacker.

  9. Experimental apparatus to determine lead attenuation coefficients for photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Vargas, Luis C.B.; Cardoso, Domingos O.; Gavazza, Sérgio; Morales, Rudnei K.; Oliveira, Luciano S. R.

    2017-01-01

    Radioactive gamma-emitting sources with higher energies than 1.022 MeV, may interact with matter by pair production process, generating two photons of 0.511 MeV in the positron annihilation, that may contribute to increase doses in both IOE´s or public. National regulatory agencies require a radiation protection plan and a shielding project to consider the influence of these photons in the licensing procedure. This work will present all steps for the development of the experimental apparatus for determination of the attenuation coefficients for photons with energy of 0.511 MeV in lead. (author)

  10. Natural gas hydrates. Experimental techniques and their applications

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Yuguang; Liu, Changling (eds.) [Qingdao Institute of Marine Geology (China). Gas Hydrate Laboratory

    2013-07-01

    Focuses on gas hydrate experiment in laboratory. Intends to provide practical significant parameters for gas hydrate exploration and exploitation in the oceanic and permafrost environments. Consists of different themes that present up-to-date information on hydrate experiments. ''Natural Gas Hydrates: Experimental Techniques and Their Applications'' attempts to broadly integrate the most recent knowledge in the fields of hydrate experimental techniques in the laboratory. The book examines various experimental techniques in order to provide useful parameters for gas hydrate exploration and exploitation. It provides experimental techniques for gas hydrates, including the detection techniques, the thermo-physical properties, permeability and mechanical properties, geochemical abnormalities, stability and dissociation kinetics, exploitation conditions, as well as modern measurement technologies etc.

  11. CFT and RTD methods for wastewater treatment plants apparatus investigation

    International Nuclear Information System (INIS)

    Palige, J.; Owczarczyk, A.; Dobrowolski, A.; Ptaszek, S.

    2006-01-01

    Two methods, residence time distributions (RTD) and computational fluid dynamics (CFD) are most effective for solid and wastewater phases investigations of flow dynamics. On the basis of measured (in tracer experiment) RTD function, the model of flow can be proposed for the unit under investigation. The experimental and numerical RTD functions were compared for different technological parameters values of processes (apparatus geometry, flow rate, location and construction of input and output). Numerical RTD function was obtained by DRW (discrete random walk) technique - determination of residence times of many liquid particles. The usefulness of these techniques was checked on a large scale laboratory model of settler. Satisfactory agreement of the data obtained by both methods - tracer and CFD - was observed

  12. How-to-Do-It: Apparatus & Experimental Design for Measuring Fermentation Rates in Yeast.

    Science.gov (United States)

    Tatina, Robert

    1989-01-01

    Describes an apparatus that facilitates the quantitative study of fermentation in yeast by allowing simultaneous measurements of fermentation rates in several treatments and a control. Explains a laboratory procedure in which the apparatus is used. Several suggestions for further investigations are included. (Author/RT)

  13. Building scientific apparatus

    National Research Council Canada - National Science Library

    Moore, John H; Davis, Christopher C; Coplan, Michael A; Greer, Sandra C

    2009-01-01

    ... specification of the components of apparatus, many new to this edition. Data on the properties of materials and components used by manufacturers are included. Mechanical, optical, and electronic construction techniques carried out in the laboratory, as well as those let out to specialized shops, are also described. Step-by-step instruc...

  14. A multifunctional microwave plasma reaction apparatus and its applications

    International Nuclear Information System (INIS)

    Wang Xizhang; Wu Qiang; Hu Zheng; Xu Hua; Miao Shui; Chen Yi

    2000-01-01

    A multifunctional apparatus for microwave plasma reaction has been set up, which can be used in the fields such as chemical synthesis, surface modification, and heterogeneous catalysis. The apparatus has laid an experimental foundation for new methods, new technologies, and new train of thoughts to be explored

  15. Dynamic Tensile Experimental Techniques for Geomaterials: A Comprehensive Review

    Science.gov (United States)

    Heard, W.; Song, B.; Williams, B.; Martin, B.; Sparks, P.; Nie, X.

    2018-01-01

    This review article is dedicated to the Dynamic Behavior of Materials Technical Division for celebrating the 75th anniversary of the Society for Experimental Mechanics (SEM). Understanding dynamic behavior of geomaterials is critical for analyzing and solving engineering problems of various applications related to underground explosions, seismic, airblast, and penetration events. Determining the dynamic tensile response of geomaterials has been a great challenge in experiments due to the nature of relatively low tensile strength and high brittleness. Various experimental approaches have been made in the past century, especially in the most recent half century, to understand the dynamic behavior of geomaterials in tension. In this review paper, we summarized the dynamic tensile experimental techniques for geomaterials that have been developed. The major dynamic tensile experimental techniques include dynamic direct tension, dynamic split tension, and spall tension. All three of the experimental techniques are based on Hopkinson or split Hopkinson (also known as Kolsky) bar techniques and principles. Uniqueness and limitations for each experimental technique are also discussed.

  16. Experimental apparatus with {sup 3}He detectors for photoneutron measurements greater than 8 MV; Aparato experimental de detector {sup 3}He, para medida fotonêutrons em acelerador com energia acima 8 MV

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Marcelo Vilela da; Fontes, Gladson Silva; Cardoso, Domingos D’Oliveira, E-mail: marcelovilelasilva@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Particle technology has a profound impact on society. Its applications are well established mainly in the treatment of cancer and other diseases. The objective of this work was to develop an experimental apparatus with {sup 3}He detectors for photoneutron measurements greater than 8 MV. The apparatus allowed to obtain a multi energetic neutron measurements with detector and changing the different thicknesses of shields and for different dose rates. Additionally, an analytical model was developed, based on the approximation of the diffusion, for two groups of energy. The results indicated an increasing and linear behavior in the detector response. (author)

  17. Experimental techniques and measurement accuracies

    International Nuclear Information System (INIS)

    Bennett, E.F.; Yule, T.J.; DiIorio, G.; Nakamura, T.; Maekawa, H.

    1985-02-01

    A brief description of the experimental tools available for fusion neutronics experiments is given. Attention is paid to error estimates mainly for the measurement of tritium breeding ratio in simulated blankets using various techniques

  18. An experimental apparatus to simulate body-powered prosthetic usage: Development and preliminary evaluation.

    Science.gov (United States)

    Gao, Fan; Rodriguez, Johanan; Kapp, Susan

    2016-06-01

    Harness fitting in the body-powered prosthesis remains more art than science due to a lack of consistent and quantitative evaluation. The aim of this study was to develop a mechanical, human-body-shaped apparatus to simulate body-powered upper limb prosthetic usage and evaluate its capability of quantitative examination of harness configuration. The apparatus was built upon a torso of a wooden mannequin and integrated major mechanical joints to simulate terminal device operation. Sensors were used to register cable tension, cable excursion, and grip force simultaneously. The apparatus allowed the scapula to move up to 127 mm laterally and the load cell can measure the cable tension up to 445 N. Our preliminary evaluation highlighted the needs and importance of investigating harness configurations in a systematic and controllable manner. The apparatus allows objective, systematic, and quantitative evaluation of effects of realistic harness configurations and will provide insightful and working knowledge on harness fitting in upper limb amputees using body-powered prosthesis. © The International Society for Prosthetics and Orthotics 2015.

  19. High-frequency signal paths in the TMR-86.1 experimental tomography apparatus

    International Nuclear Information System (INIS)

    Obrcian, J.; Jellus, V.; Weis, J.; Frollo, I.

    1990-01-01

    The NMR-based TMR-86.1 tomography apparatus, developed at the Institute of Measurement and Measuring Instrumentation, Slovak Academy of Sciences in Bratislava, Czechoslovakia, enables imaging of the inner structure of biological samples and human limbs no more than 110 mm in diameter, using a measuring matrix containing at most 128x128 elements. The imaged matrix can possess a maximum of 256x256 image elements with 256 brightness steps. The signal paths of the high-frequency excitation-imaging complex of the apparatus are described. Some functional blocks of the apparatus can be used without substantial modifications for the imaging of larger objects such as the human body. From the point of view of the high-frequency pulses for nonselective excitation (so-called 180deg-pulses), the excitation pulse power will have to be increased to at least 1 kW. (author). 5 figs, 7 refs

  20. Design and Analysis of A Spin-Stabilized Projectile Experimental Apparatus

    Science.gov (United States)

    Siegel, Noah; Rodebaugh, Gregory; Elkins, Christopher; van Poppel, Bret; Benson, Michael; Cremins, Michael; Lachance, Austin; Ortega, Raymond; Vanderyacht, Douglas

    2017-11-01

    Spinning objects experience an effect termed `The Magnus Moment' due to an uneven pressure distribution based on rotation within a crossflow. Unlike the Magnus force, which is often small for spin-stabilized projectiles, the Magnus moment can have a strong detrimental effect on aerodynamic flight stability. Simulations often fail to accurately predict the Magnus moment in the subsonic flight regime. In an effort to characterize the conditions that cause the Magnus moment, researchers in this work employed Magnetic Resonance Velocimetry (MRV) techniques to measure three dimensional, three component, sub-millimeter resolution fluid velocity fields around a scaled model of a spinning projectile in flight. The team designed, built, and tested using a novel water channel apparatus that was fully MRI-compliant - water-tight and non-ferrous - and capable of spinning a projectile at a constant rotational speed. A supporting numerical simulation effort informed the design process of the scaled projectile to thicken the hydrodynamic boundary layer near the outer surface of the projectile. Preliminary testing produced two-dimensional and three-dimensional velocity data and revealed an asymmetric boundary layer around the projectile, which is indicative of the Magnus effect.

  1. Experimental techniques; Techniques experimentales

    Energy Technology Data Exchange (ETDEWEB)

    Roussel-Chomaz, P. [GANIL CNRS/IN2P3, CEA/DSM, 14 - Caen (France)

    2007-07-01

    This lecture presents the experimental techniques, developed in the last 10 or 15 years, in order to perform a new class of experiments with exotic nuclei, where the reactions induced by these nuclei allow to get information on their structure. A brief review of the secondary beams production methods will be given, with some examples of facilities in operation or under project. The important developments performed recently on cryogenic targets will be presented. The different detection systems will be reviewed, both the beam detectors before the targets, and the many kind of detectors necessary to detect all outgoing particles after the reaction: magnetic spectrometer for the heavy fragment, detection systems for the target recoil nucleus, {gamma} detectors. Finally, several typical examples of experiments will be detailed, in order to illustrate the use of each detector either alone, or in coincidence with others. (author)

  2. PIPER-ONE: an experimental apparatus to evaluate thermal-hydraulic transients in BWRs after small breaks

    International Nuclear Information System (INIS)

    Mazzini, M.; D'Auria, F.; Vigni, P.

    1981-01-01

    This paper deals with the state of art of the research performed at the Instituto di Impianti Nucleari of Pisa University, aiming at construction of PIPER-ONE experimental facility. PIPER-ONE program is devoted to acquire direct experience on some basic phenomena, arising in BWR plants subsequently to small breaks, and on the use of the main thermal-hydraulic codes. The research has been planned taking into consideration recent trends of the studies all over the world of small LOCA thermal-hydraulics and particular needs of nuclear safety in Italy. Cost limitations and availability of some components, already installed at the Institute Laboratory, have influenced the design of the loop. The development steps of PIPER-ONE project are presented. Particularly, the overall flowsheet of the apparatus is reported. Some results of preliminary calculation, executed by RELAP4-Mod 6 code concerning both the experimental loop and the reference BWR are shown, too. A comparison with similar facilities in the world closes the paper

  3. Experimental Technique of Titanium Fire in Aero-engine

    Directory of Open Access Journals (Sweden)

    MI Guangbao

    2016-06-01

    Full Text Available Titanium fire is the typical catastrophic fault in the aero-engine. Aiming at the urgent demand for experimental technique of titanium fire from advanced high thrust-weight ratio aero-engine, the combustion technology and theory of titanium alloy based on friction oxygen concentration method (FOC were systematically studied. The evaluation method of fireproof property and the friction ignition model were built, and the fireproof mechanism was illustrated. By generalizing recent progress in experimental technique of titanium fire from three levels, including evolutionary rule, mechanism and prevention and control technology, the ideas and directions of experimental technique associated with the application research of titanium fire in the future were proposed, namely overall evaluation of fireproof property close to air flow environment of the aero-engine, prediction model of fireproof property and experimental verification of fireproof technique under the air flow environment of aero-engine. It is necessary to establish the prevention system of titanium fire in aero-engine, which contributes to the realization of "full titanium" in compressor and to the increase of high thrust-weight ratio.

  4. Development of experimental apparatus for evaluating corrosion resistance of cladding materials applied for advanced power reactor. 1

    International Nuclear Information System (INIS)

    Inohara, Yasuto; Ioka, Ikuo; Fukaya, Kiyoshi; Tachibana, Katsumi; Suzuki, Tomio; Kiuchi, Kiyoshi

    2001-03-01

    On the development of cladding materials for advanced power reactors, it is important to clarify long performance and to control the compatibility to high temperature water at heat conducting surfaces under heavy irradiation. On the present study, the high temperature water loop with an autoclave was made for examining the corrosion behavior up to the super critical water range and for developing the simulation testing technique under irradiation in the hot cell. The loop is applicable to immersion tests in the temperature and pressure ranges up to 450degC and 25 MPa that are covered the surface temperature range of fuel claddings. One of the characteristics of this apparatus is a pair of sapphire windows of autoclave for in-situ observations, and a phase transition from water to super critical water conditions was clearly verified through these windows. In this apparatus, it is possible to control the temperature, pressure and Dissolved Oxygen (DO) within a fluctuations of few % on three phases, namely, water, steam and super critical water. (author)

  5. A new apparatus to induce lysis of planktonic microbial cells by shock compression, cavitation and spray

    Science.gov (United States)

    Schiffer, A.; Gardner, M. N.; Lynn, R. H.; Tagarielli, V. L.

    2017-03-01

    Experiments were conducted on an aqueous growth medium containing cultures of Escherichia coli (E. coli) XL1-Blue, to investigate, in a single experiment, the effect of two types of dynamic mechanical loading on cellular integrity. A bespoke shock tube was used to subject separate portions of a planktonic bacterial culture to two different loading sequences: (i) shock compression followed by cavitation, and (ii) shock compression followed by spray. The apparatus allows the generation of an adjustable loading shock wave of magnitude up to 300 MPa in a sterile laboratory environment. Cultures of E. coli were tested with this apparatus and the spread-plate technique was used to measure the survivability after mechanical loading. The loading sequence (ii) gave higher mortality than (i), suggesting that the bacteria are more vulnerable to shear deformation and cavitation than to hydrostatic compression. We present the results of preliminary experiments and suggestions for further experimental work; we discuss the potential applications of this technique to sterilize large volumes of fluid samples.

  6. Differential sensor in front photopyroelectric technique: II. Experimental

    International Nuclear Information System (INIS)

    Ivanov, R; Moreno, I; Araujo-Andrade, C; MarIn, E; Cruz-Orea, A; Pichardo-Molina, J L

    2009-01-01

    We describe the differential cell design and the experimental (optical and electronic) setup for the differential front photopyroelectric technique, whose theory has been developed in the first part of this paper (Ivanov et al 2008 J. Phys. D: Appl. Phys. 41 085106). We will show first how the direct (non-differential) front photopyroelectric theory described in our previous paper reproduces well the experimental results. The usefulness of the differential technique is demonstrated by means of experimental measurements of the thermal effusivity in binary ethanol-water and glycerol-water mixtures, based on a theoretical methodology that simplifies the measurement procedure and diminishes the experimental uncertainty.

  7. Differential sensor in front photopyroelectric technique: II. Experimental

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, R; Moreno, I; Araujo-Andrade, C [Facultad de Fisica, Universidad Autonoma de Zacatecas, Calz. Solidaridad Esquina Paseo de la Bufa s/n, CP 98060, Zacatecas, Zac. (Mexico); MarIn, E [Centro de Investigacion en Ciencia Aplicada y TecnologIa Avanzada-Instituto Politecnico Nacional, Legaria 694, Col. Irrigacion, CP 11500, Mexico D.F. (Mexico); Cruz-Orea, A [Departamento de Fisica, CINVESTAV-IPN, Av. IPN No. 2508, Col. San Pedro Zacatenco, CP 07360, Mexico D.F. (Mexico); Pichardo-Molina, J L, E-mail: rumen@fisica.uaz.edu.m [Centro de Investigaciones en Optica, Loma del Bosque 115, Loma del Campestre, CP 37150, Leon, Guanajuato (Mexico)

    2009-06-21

    We describe the differential cell design and the experimental (optical and electronic) setup for the differential front photopyroelectric technique, whose theory has been developed in the first part of this paper (Ivanov et al 2008 J. Phys. D: Appl. Phys. 41 085106). We will show first how the direct (non-differential) front photopyroelectric theory described in our previous paper reproduces well the experimental results. The usefulness of the differential technique is demonstrated by means of experimental measurements of the thermal effusivity in binary ethanol-water and glycerol-water mixtures, based on a theoretical methodology that simplifies the measurement procedure and diminishes the experimental uncertainty.

  8. Leak detection of complex pipelines based on the filter diagonalization method: robust technique for eigenvalue assessment

    International Nuclear Information System (INIS)

    Lay-Ekuakille, Aimé; Pariset, Carlo; Trotta, Amerigo

    2010-01-01

    The FDM (filter diagonalization method), an interesting technique used in nuclear magnetic resonance data processing for tackling FFT (fast Fourier transform) limitations, can be used by considering pipelines, especially complex configurations, as a vascular apparatus with arteries, veins, capillaries, etc. Thrombosis, which might occur in humans, can be considered as a leakage for the complex pipeline, the human vascular apparatus. The choice of eigenvalues in FDM or in spectra-based techniques is a key issue in recovering the solution of the main equation (for FDM) or frequency domain transformation (for FFT) in order to determine the accuracy in detecting leaks in pipelines. This paper deals with the possibility of improving the leak detection accuracy of the FDM technique thanks to a robust algorithm by assessing the problem of eigenvalues, making it less experimental and more analytical using Tikhonov-based regularization techniques. The paper starts from the results of previous experimental procedures carried out by the authors

  9. Experimental techniques

    International Nuclear Information System (INIS)

    Roussel-Chomaz, P.

    2007-01-01

    This lecture presents the experimental techniques, developed in the last 10 or 15 years, in order to perform a new class of experiments with exotic nuclei, where the reactions induced by these nuclei allow to get information on their structure. A brief review of the secondary beams production methods will be given, with some examples of facilities in operation or under project. The important developments performed recently on cryogenic targets will be presented. The different detection systems will be reviewed, both the beam detectors before the targets, and the many kind of detectors necessary to detect all outgoing particles after the reaction: magnetic spectrometer for the heavy fragment, detection systems for the target recoil nucleus, γ detectors. Finally, several typical examples of experiments will be detailed, in order to illustrate the use of each detector either alone, or in coincidence with others. (author)

  10. An apparatus for preparing isotopically pure He4

    International Nuclear Information System (INIS)

    McClintock, P.V.E.

    1978-01-01

    A cryostat has been constructed for extracting pure He 4 from He II of natural isotopic composition by means of a heat flush technique. It is shown that the method is in principle capable of yielding He 4 which is entirely devoid of He 3 isotopic impurities. A secondary heat flush, operated in conjunction with a conical heat exchanger of novel design, was used to place an experimental lower bound of 2 x 10 15 on the He 4 /He 3 ratio of the product, a standard sufficient for all present or projected applications requiring isotopically pure He 4 . The apparatus produces 2 000 1 (at standard temperature and pressure) of He 4 per thermal cycle. The design of future purifiers is discussed. (author)

  11. A new crossed molecular beam apparatus using time-sliced ion velocity imaging technique

    International Nuclear Information System (INIS)

    Wu Guorong; Zhang Weiqing; Pan Huilin; Shuai Quan; Jiang Bo; Dai Dongxu; Yang Xueming

    2008-01-01

    A new crossed molecular beam apparatus has been constructed for investigating polyatomic chemical reactions using the time-sliced ion velocity map imaging technique. A unique design is adopted for one of the two beam sources and allows us to set up the molecular beam source either horizontally or vertically. This can be conveniently used to produce versatile atomic or radical beams from photodissociation and as well as electric discharge. Intensive H-atom beam source with high speed ratio was produced by photodissociation of the HI molecule and was reacted with the CD 4 molecule. Vibrational-state resolved HD product distribution was measured by detecting the CD 3 product. Preliminary results were also reported on the F+SiH 4 reaction using the discharged F atom beam. These results demonstrate that this new instrument is a powerful tool for investigating chemical dynamics of polyatomic reactions.

  12. Flash radiographic technique applied to fuel injector sprays

    International Nuclear Information System (INIS)

    Vantine, H.C.

    1977-01-01

    A flash radiographic technique, using 50 ns exposure times, was used to study the pattern and density distribution of a fuel injector spray. The experimental apparatus and method are described. An 85 kVp flash x-ray generator, designed and fabricated at the Lawrence Livermore Laboratory, is utilized. Radiographic images, recorded on standard x-ray films, are digitized and computer processed

  13. Testing of defects in Si semiconductor apparatus by using single-photon detection

    International Nuclear Information System (INIS)

    Zhongliang, Pan; Ling, Chen; Guangju, Chen

    2013-01-01

    The failure analysis of semiconductor apparatus is very needed for ensuring product quality, which can find several types of defects in the semiconductor apparatus. A new testing method for the defects in Si semiconductor apparatus is presented in this paper, the method makes use of photon emissions to find out the failure positions or failure components by taking advantage of the infrared photo emission characteristics of semiconductor apparatus. These emitted photons carry the information of the apparatus structure. If there are defects in the apparatus, these photons can help in understanding the apparatus properties and detecting the defects. An algorithm for the generation of circuit input vectors are presented in this paper to enhance the strength of the emitted photons for the given components in the semiconductor apparatus. The multiple-valued logic, the static timing analysis and path sensitizations, are used in the algorithm. A lot of experimental results for the Si semiconductor apparatus show that many types of defects such as contact spiking and latchup failure etc., can be detected accurately by the method proposed in this paper

  14. [Intestinal lengthening techniques: an experimental model in dogs].

    Science.gov (United States)

    Garibay González, Francisco; Díaz Martínez, Daniel Alberto; Valencia Flores, Alejandro; González Hernández, Miguel Angel

    2005-01-01

    To compare two intestinal lengthening procedures in an experimental dog model. Intestinal lengthening is one of the methods for gastrointestinal reconstruction used for treatment of short bowel syndrome. The modification to the Bianchi's technique is an alternative. The modified technique decreases the number of anastomoses to a single one, thus reducing the risk of leaks and strictures. To our knowledge there is not any clinical or experimental report that studied both techniques, so we realized the present report. Twelve creole dogs were operated with the Bianchi technique for intestinal lengthening (group A) and other 12 creole dogs from the same race and weight were operated by the modified technique (Group B). Both groups were compared in relation to operating time, difficulties in technique, cost, intestinal lengthening and anastomoses diameter. There were no statistical difference in the anastomoses diameter (A = 9.0 mm vs. B = 8.5 mm, p = 0.3846). Operating time (142 min vs. 63 min) cost and technique difficulties were lower in group B (p anastomoses (of Group B) and intestinal segments had good blood supply and were patent along their full length. Bianchi technique and the modified technique offer two good reliable alternatives for the treatment of short bowel syndrome. The modified technique improved operating time, cost and technical issues.

  15. Apparatus and method for implementing power saving techniques when processing floating point values

    Science.gov (United States)

    Kim, Young Moon; Park, Sang Phill

    2017-10-03

    An apparatus and method are described for reducing power when reading and writing graphics data. For example, one embodiment of an apparatus comprises: a graphics processor unit (GPU) to process graphics data including floating point data; a set of registers, at least one of the registers of the set partitioned to store the floating point data; and encode/decode logic to reduce a number of binary 1 values being read from the at least one register by causing a specified set of bit positions within the floating point data to be read out as 0s rather than 1s.

  16. A new apparatus for electron-ion multiple coincidence momentum imaging spectroscopy

    International Nuclear Information System (INIS)

    Morishita, Y.; Kato, M.; Pruemper, G.; Liu, X.-J.; Lischke, T.; Ueda, K.; Tamenori, Y.; Oura, M.; Yamaoka, H.; Suzuki, I.H.; Saito, N.

    2006-01-01

    We have developed a new experimental apparatus for the electron-ion multiple coincidence momentum imaging spectroscopy in order to obtain the angular distributions of vibration-resolved photoelectrons from molecules fixed in space. The apparatus consists of a four-stage molecular supersonic jet and a spectrometer analyzing three-dimensional momenta of fragment ions and electrons in coincidence

  17. Analysis apparatus and method of analysis

    International Nuclear Information System (INIS)

    1976-01-01

    A continuous streaming method developed for the excution of immunoassays is described in this patent. In addition, a suitable apparatus for the method was developed whereby magnetic particles are automatically employed for the consecutive analysis of a series of liquid samples via the RIA technique

  18. Apparatus for Measurements of Time and Space Correlation

    Science.gov (United States)

    Favre, Alexandre; Gaviglio, J; Dumas, R

    1955-01-01

    A brief review is made of improvements to an experimental apparatus for time and space correlation designed for study of turbulence. Included is a description of the control of the measurements and a few particular applications.

  19. Experimental test of a new technique of background suppression in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Bisogni, M.G.; Bottari, S.; Ciocci, M.A.; Fantacci, M.E.; Maestro, P.; Malakhov, N.; Marrocchesi, P.S. E-mail: marrocchesi@pi.infn.it; Novelli, M.; Quattrocchi, M.; Pilo, F.; Rosso, V.; Turini, N.; Zucca, S

    2002-02-01

    A multiple-exposure technique in digital mammography has been developed to suppress the physical background in the image due to Compton scattering in the body. A pair of X-ray masks, shaped in a projective geometry and positioned upstream and downstream the patient, are coupled mechanically and moved in four steps along a square pattern in order to irradiate the full area in four consecutive short exposures. A proof-of-principle apparatus is under test with a breast phantom and a standard mammographic X-ray unit. Results are reported.

  20. Experimental test of a new technique of background suppression in digital mammography

    International Nuclear Information System (INIS)

    Bisogni, M.G.; Bottari, S.; Ciocci, M.A.; Fantacci, M.E.; Maestro, P.; Malakhov, N.; Marrocchesi, P.S.; Novelli, M.; Quattrocchi, M.; Pilo, F.; Rosso, V.; Turini, N.; Zucca, S.

    2002-01-01

    A multiple-exposure technique in digital mammography has been developed to suppress the physical background in the image due to Compton scattering in the body. A pair of X-ray masks, shaped in a projective geometry and positioned upstream and downstream the patient, are coupled mechanically and moved in four steps along a square pattern in order to irradiate the full area in four consecutive short exposures. A proof-of-principle apparatus is under test with a breast phantom and a standard mammographic X-ray unit. Results are reported

  1. Electro-Optical Sensing Apparatus and Method for Characterizing Free-Space Electromagnetic Radiation

    Science.gov (United States)

    Zhang, Xi-Cheng; Libelo, Louis Francis; Wu, Qi

    1999-09-14

    Apparatus and methods for characterizing free-space electromagnetic energy, and in particular, apparatus/method suitable for real-time two-dimensional far-infrared imaging applications are presented. The sensing technique is based on a non-linear coupling between a low-frequency electric field and a laser beam in an electro-optic crystal. In addition to a practical counter-propagating sensing technique, a co-linear approach is described which provides longer radiated field--optical beam interaction length, thereby making imaging applications practical.

  2. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  3. Semiconductor apparatus and method of fabrication for a semiconductor apparatus

    NARCIS (Netherlands)

    2010-01-01

    The invention relates to a semiconductor apparatus (1) and a method of fabrication for a semiconductor apparatus (1), wherein the semiconductor apparatus (1) comprises a semiconductor layer (2) and a passivation layer (3), arranged on a surface of the semiconductor layer (2), for passivating the

  4. An experimental apparatus for diffraction-limites soft x-ray nanofocusing

    Energy Technology Data Exchange (ETDEWEB)

    Merthe, Daniel; Goldberg, Kenneth; Yashchuk, Valeriy; Yuan, Sheng; McKinney, Wayne; Celestre, Richard; Mochi, Iacopo; Macdougall, James; Morrison, Gregory; Rakawa, Senajith; Anderson, Erik; Smith, Brian; Domning, Edward; Warwick, Tony; Padmore, Howard

    2011-10-21

    Realizing the experimental potential of high-brightness, next generation synchrotron and free-electron laser light sources requires the development of reflecting x-ray optics capable of wavefront preservation and high-resolution nano-focusing. At the Advanced Light Source (ALS) beamline 5.3.1, we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad slope measurement accuracy for diffraction-limited Kirkpatrick-Baez (KB) mirrors. The at-wavelength methodology we are developing relies on a series of wavefront-sensing tests with increasing accuracy and sensitivity, including scanning-slit Hartmann tests, grating-based lateral shearing interferometry, and quantitative knife-edge testing. We describe the original experimental techniques and alignment methodology that have enabled us to optimally set a bendable KB mirror to achieve a focused, FWHM spot size of 150 nm, with 1 nm (1.24 keV) photons at 3.7 mrad numerical aperture. The predictions of wavefront measurement are confirmed by the knife-edge testing.The side-profiled elliptically bent mirror used in these one-dimensional focusing experiments was originally designed for a much different glancing angle and conjugate distances. This work demonstrates that high-accuracy, at-wavelength wavefront-slope feedback can be used to optimize the pitch, roll, and mirror-bending forces in situ, using procedures that are deterministic and repeatable.

  5. Production of molten UO2 pools by internal heating: apparatus and preliminary experimental heat transfer results

    International Nuclear Information System (INIS)

    Chasanov, M.G.; Gunther, W.H.; Baker, L. Jr.

    1977-01-01

    The capability for removal of heat from a pool of molten fuel under postaccident conditions is an important consideration in liquid-metal fast breeder reactor safety analysis. No experimental data for pool heat transfer from molten UO 2 under conditions simulating internal heat generation by fission product decay have been reported previously in the literature. An apparatus to provide such data was developed and used to investigate heat transfer from pools containing up to 7.5 kg of UO 2 ; the internal heat generation rates and pool depths attained cover most of the ranges of interest for postaccident heat removal analysis. It was also observed in these studies that the presence of simulated fission products corresponding to approximately 150,000 kW-day/kg burnup had no significant effect on the observed heat transfer

  6. Applied measuring techniques for the investigation of time-dependent flow phenomena in centrifugal compressors

    International Nuclear Information System (INIS)

    Hass, U.; Haupt, U.; Jansen, M.; Kassens, K.; Knapp, P.; Rautenberg, M.

    1978-01-01

    During the past 10 years new measuring techniques have been developed for the experimental investigation of highly loaded centrifugal compressors. These measuring techniques take into account the time dependency of the fluctuating physical quantities such as pressure, temperature, and velocity. Some key points of these experimental techniques are shown and explained in this paper. An important basis for such measurements is the accurate dynamic calibration of the measuring apparatus. In addition, some problems involved analyzing measured signals are dealt with and pressure measurements and their interpretation are shown. Finally optical, acoustical and vibrational measuring procedures are described which are additionally used for the investigation of non-stationary flow phenomena. (orig.) [de

  7. Experimental techniques in nuclear and particle physics

    International Nuclear Information System (INIS)

    Tavernier, Stefaan

    2010-01-01

    The book is based on a course in nuclear and particle physics that the author has taught over many years to physics students, students in nuclear engineering and students in biomedical engineering. It provides the basic understanding that any student or researcher using such instruments and techniques should have about the subject. After an introduction to the structure of matter at the subatomic scale, it covers the experimental aspects of nuclear and particle physics. Ideally complementing a theoretically-oriented textbook on nuclear physics and/or particle physics, it introduces the reader to the different techniques used in nuclear and particle physics to accelerate particles and to measurement techniques (detectors) in nuclear and particle physics. The main subjects treated are: interactions of subatomic particles in matter; particle accelerators; basics of different types of detectors; and nuclear electronics. The book will be of interest to undergraduates, graduates and researchers in both particle and nuclear physics. For the physicists it is a good introduction to all experimental aspects of nuclear and particle physics. Nuclear engineers will appreciate the nuclear measurement techniques, while biomedical engineers can learn about measuring ionising radiation, the use of accelerators for radiotherapy. What's more, worked examples, end-of-chapter exercises, and appendices with key constants, properties and relationships supplement the textual material. (orig.)

  8. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    Energy Technology Data Exchange (ETDEWEB)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C. [Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy); Gupta, A. [Department of Chemistry, University of Alabama, Tuscaloosa, Alabama 35487 (United States); Carpene, E., E-mail: ettore.carpene@polimi.it [CNR-IFN, Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-01-15

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO{sub 2} single crystals as a benchmark.

  9. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    International Nuclear Information System (INIS)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C.; Gupta, A.; Carpene, E.

    2015-01-01

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO 2 single crystals as a benchmark

  10. Phase equilibria basic principles, applications, experimental techniques

    CERN Document Server

    Reisman, Arnold

    2013-01-01

    Phase Equilibria: Basic Principles, Applications, Experimental Techniques presents an analytical treatment in the study of the theories and principles of phase equilibria. The book is organized to afford a deep and thorough understanding of such subjects as the method of species model systems; condensed phase-vapor phase equilibria and vapor transport reactions; zone refining techniques; and nonstoichiometry. Physicists, physical chemists, engineers, and materials scientists will find the book a good reference material.

  11. Exploring a new paradigm for accelerators and large experimental apparatus control systems

    International Nuclear Information System (INIS)

    Catani, L.; Ammendola, R.; Zani, F.; Bisegni, C.; Ciuffetti, P.; Di Pirro, G.; Mazzitelli, G.; Stecchi, A.; Calabro, S.; Foggetta, L.

    2012-01-01

    The integration of web technologies and web services has been, in the recent years, one of the major trends in upgrading and developing control systems for accelerators and large experimental apparatuses. Usually, web technologies have been introduced to complement the control systems with smart add-on and user friendly services or, for instance, to safely allow access to the control system to users from remote sites. Despite this still narrow spectrum of employment, some software technologies developed for high performance web services, although originally intended and optimized for these particular applications, deserve some features that would allow their deeper integration in a control system and, eventually, using them to develop some of the control system's core components. In this paper we present the conclusion of the preliminary investigations of a new design for an accelerator control system and associated machine data acquisition system (DAQ), based on a synergic combination of network distributed object caching (DOC) and a non-relational key/value database (KVDB). We investigated these technologies with particular interest on performances, namely speed of data storage and retrieve for the distributed caching, data throughput and queries execution time for the database and, especially, how much this performances can benefit from their inherent adaptability. (authors)

  12. Evolutionary optimization of an experimental apparatus

    DEFF Research Database (Denmark)

    Geisel, Ilka; Cordes, Kai; Mahnke, Jan

    2013-01-01

    algorithm based on differential evolution. We demonstrate that this algorithm optimizes 21 correlated parameters and that it is robust against local maxima and experimental noise. The algorithm is flexible and easy to implement. Thus, the presented scheme can be applied to a wide range of experimental...

  13. ROLLER FILTRATION APPARATUS

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter and liquid from a m...

  14. The design and realization of calibration apparatus for measuring the concentration of radon in three models

    Energy Technology Data Exchange (ETDEWEB)

    Huiping, Guo [The Second Artillery Engineering College, Xi' an (China)

    2007-06-15

    For satisfying calibration request of radon measure in the laboratory, the calibration apparatus for radon activity measure is designed and realized. The calibration apparatus can auto-control and auto-measure in three models. sequent mode, pulse mode and constant mode. The stability and reliability of the calibration apparatus was tested under the three models. The experimental result shows that the apparatus can provides an adjustable and steady radon activity concentration environment for the research of radon and its progeny and for the calibration of its measure. (authors)

  15. Multipactor discharge apparatus

    International Nuclear Information System (INIS)

    1976-01-01

    The invention deals with a multipactor discharge apparatus which can be used for tuning microwave organs such as magnetron oscillators and other cavity resonators. This apparatus is suitable for delivering an improved tuning effect in a resonation organ wherefrom the working frequency must be set. This apparatus is equipped with two multipactor discharge electrodes set in a configuration such to that a net current flows from one electrode to another. These electrodes are parallel and flat. The apparatus can be used in magnetron devices as well for continuous waves as for impulses

  16. Frequency-Dependent Streaming Potential of Porous Media—Part 1: Experimental Approaches and Apparatus Design

    Directory of Open Access Journals (Sweden)

    P. W. J. Glover

    2012-01-01

    Full Text Available Electrokinetic phenomena link fluid flow and electrical flow in porous and fractured media such that a hydraulic flow will generate an electrical current and vice versa. Such a link is likely to be extremely useful, especially in the development of the electroseismic method. However, surprisingly few experimental measurements have been carried out, particularly as a function of frequency because of their difficulty. Here we have considered six different approaches to make laboratory determinations of the frequency-dependent streaming potential coefficient. In each case, we have analyzed the mechanical, electrical, and other technical difficulties involved in each method. We conclude that the electromagnetic drive is currently the only approach that is practicable, while the piezoelectric drive may be useful for low permeability samples and at specified high frequencies. We have used the electro-magnetic drive approach to design, build, and test an apparatus for measuring the streaming potential coefficient of unconsolidated and disaggregated samples such as sands, gravels, and soils with a diameter of 25.4 mm and lengths between 50 mm and 300 mm.

  17. Oscillation experiments techniques in CEA Minerve experimental reactor

    Energy Technology Data Exchange (ETDEWEB)

    Antony, M.; Di-Salvo, J.; Pepino, A.; Bosq, J. C.; Bernard, D.; Leconte, P.; Hudelot, J. P.; Lyoussi, A. [CEA CADARACHE, DEN/DER/SPEx, 13108 Saint Paul-lez-Durance (France)

    2009-07-01

    This paper deals with experiments in the Minerve pool Zero Power Reactor. Minerve is mainly devoted to neutronics studies, in view to improve the calculation routes by reducing the uncertainties of the experimental databases for nuclides arising in plutonium and wastes management. Minerve experimental measurement programs are performed by using the oscillation technique. This experimental technique consists in a periodic insertion and extraction of samples containing the nuclide of interest in a well characterized neutron spectrum. The reactivity variation of the sample is compensated by a calibrated rotary automatic pilot using cadmium sectors. The normal accuracy for measurements of small-worth samples in Minerve by using such a technique is about 3% for absolute reactivity worth, including the uncertainties on the material balance and on the calibration step. Reactivity effects of less than 1.5 cent can be measured. The OSMOSE and the OCEAN programs have been carried out since 2005 and will last until 2011. These programs aim at improving, in different neutron spectra, the absorption cross sections of respectively a majority of the separated heavy nuclides from {sup 232}Th to {sup 245}Cm appearing during the reactor and the fuel cycle physics, and of current and future types of absorbers as Gd, Hf, Er, Dy and Eu. (authors)

  18. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  19. An automatic refolding apparatus for preparative-scale protein production.

    Directory of Open Access Journals (Sweden)

    Yanye Feng

    Full Text Available Protein refolding is an important process to recover active recombinant proteins from inclusion bodies. Refolding by simple dilution, dialysis and on-column refolding methods are the most common techniques reported in the literature. However, the refolding process is time-consuming and laborious due to the variability of the behavior of each protein and requires a great deal of trial-and-error to achieve success. Hence, there is a need for automation to make the whole process as convenient as possible. In this study, we invented an automatic apparatus that integrated three refolding techniques: varying dilution, dialysis and on-column refolding. We demonstrated the effectiveness of this technology by varying the flow rates of the dilution buffer into the denatured protein and testing different refolding methods. We carried out different refolding methods on this apparatus: a combination of dilution and dialysis for human stromal cell-derived factor 1 (SDF-1/CXCL12 and thioredoxin fused-human artemin protein (Trx-ARTN; dilution refolding for thioredoxin fused-human insulin-like growth factor I protein (Trx-IGF1 and enhanced fluorescent protein (EGFP; and on-column refolding for bovine serum albumin (BSA. The protein refolding processes of these five proteins were preliminarily optimized using the slowly descending denaturants (or additives method. Using this strategy of decreasing denaturants concentration, the efficiency of protein refolding was found to produce higher quantities of native protein. The standard refolding apparatus configuration can support different operations for different applications; it is not limited to simple dilution, dialysis and on-column refolding techniques. Refolding by slowly decreasing denaturants concentration, followed by concentration or purification on-column, may be a useful strategy for rapid and efficient recovery of active proteins from inclusion bodies. An automatic refolding apparatus employing this

  20. Low-energy ion-beam deposition apparatus equipped with surface analysis system

    International Nuclear Information System (INIS)

    Ohno, Hideki; Aoki, Yasushi; Nagai, Siro.

    1994-10-01

    A sophisticated apparatus for low energy ion beam deposition (IBD) was installed at Takasaki Radiation Chemistry Research Establishment of JAERI in March 1991. The apparatus is composed of an IBD system and a real time/in-situ surface analysis system for diagnosing deposited thin films. The IBD system provides various kinds of low energy ion down to 10 eV with current density of 10 μA/cm 2 and irradiation area of 15x15 mm 2 . The surface analysis system consists of RHEED, AES, ISS and SIMS. This report describes the characteristics and the operation procedure of the apparatus together with some experimental results on depositing thin carbon films. (author)

  1. New experimental and analysis methods in I-DLTS

    International Nuclear Information System (INIS)

    Pandey, S.U.; Middelkamp, P.; Li, Z.; Eremin, V.

    1998-02-01

    A new experimental apparatus to perform I-DLTS measurements is presented. The method is shown to be faster and more sensitive than traditional double boxcar I-DLTS systems. A novel analysis technique utilizing multiple exponential fits to the I-DLTS signal from a highly neutron irradiated silicon sample is presented with a discussion of the results. It is shown that the new method has better resolution and can deconvolute overlapping peaks more accurately than previous methods

  2. Surfaces of solids and their interactions with gaseous ambients. An introduction to the theory and experimental methods, with some examples

    International Nuclear Information System (INIS)

    Morgen, P.

    1977-10-01

    The physics and chemistry of ambient gases interacting with solid surfaces are discussed. The necessary theory and experimental techniques and apparatus used are described in detail. Results are presented for two semiconductor materials, silicon and zinc oxide. (W.D.L.)

  3. An extraordinary tabletop speed of light apparatus

    Science.gov (United States)

    Pegna, Guido

    2017-09-01

    A compact, low-cost, pre-aligned apparatus of the modulation type is described. The apparatus allows accurate determination of the speed of light in free propagation with an accuracy on the order of one part in 104. Due to the 433.92 MHz radio frequency (rf) modulation of its laser diode, determination of the speed of light is possible within a sub-meter measuring base and in small volumes (some cm3) of transparent solids or liquids. No oscilloscope is necessary, while the required function generators, power supplies, and optical components are incorporated into the design of the apparatus and its receiver can slide along the optical bench while maintaining alignment with the laser beam. Measurement of the velocity factor of coaxial cables is also easily performed. The apparatus detects the phase difference between the rf modulation of the laser diode by further modulating the rf signal with an audio frequency signal; the phase difference between these signals is then observed as the loudness of the audio signal. In this way, the positions at which the minima of the audio signal are found determine where the rf signals are completely out of phase. This phase detection method yields a much increased sensitivity with respect to the display of coincidence of two signals of questionable arrival time and somewhat distorted shape on an oscilloscope. The displaying technique is also particularly suitable for large audiences as well as in unattended exhibits in museums and science centers. In addition, the apparatus can be set up in less than one minute.

  4. Experimental techniques for single cell and single molecule biomechanics

    International Nuclear Information System (INIS)

    Lim, C.T.; Zhou, E.H.; Li, A.; Vedula, S.R.K.; Fu, H.X.

    2006-01-01

    Stresses and strains that act on the human body can arise either from external physical forces or internal physiological environmental conditions. These biophysical interactions can occur not only at the musculoskeletal but also cellular and molecular levels and can determine the health and function of the human body. Here, we seek to investigate the structure-property-function relationship of cells and biomolecules so as to understand their important physiological functions as well as establish possible connections to human diseases. With the recent advancements in cell and molecular biology, biophysics and nanotechnology, several innovative and state-of-the-art experimental techniques and equipment have been developed to probe the structural and mechanical properties of biostructures from the micro- down to picoscale. Some of these experimental techniques include the optical or laser trap method, micropipette aspiration, step-pressure technique, atomic force microscopy and molecular force spectroscopy. In this article, we will review the basic principles and usage of these techniques to conduct single cell and single molecule biomechanics research

  5. A blanket design, apparatus, and fabrication techniques for the mass production of multilayer insulation blankets for the Superconducting Super Collider

    International Nuclear Information System (INIS)

    Gonczy, J.D.; Boroski, W.N.; Niemann, R.C.; Otavka, J.G.; Ruschman, M.K.; Schoo, C.J.

    1989-09-01

    The multilayer insulation (MLI) system for the Superconducting Super Collider (SSC) consists of full cryostat length assemblies of aluminized polyester film fabricated in the form of blankets and installed as blankets to the 4.5K cold mass and the 20K and 80K thermal radiation shields. Approximately 40,000 MLI blankets will be required in the 10,000 cryogenic devices comprising the SSC accelerator. Each blanket is nearly 17 meters long and 1.8 meters wide. This paper reports the blanket design, an apparatus, and the fabrication method used to mass produce pre-fabricated MLI blankets. Incorporated in the blanket design are techniques which automate quality control during installation of the MLI blankets in the SSC cryostat. The apparatus and blanket fabrication method insure consistency in the mass produced blankets by providing positive control of the dimensional parameters which contribute to the thermal performance of the MLI blanket. By virtue of the fabrication process, the MLI blankets have inherent features of dimensional stability three-dimensional uniformity, controlled layer density, layer-to-layer registration, interlayer cleanliness, and interlayer material to accommodate thermal contraction differences. 11 refs., 6 figs., 1 tab

  6. Method and apparatus for controlling LCL converters using asymmetric voltage cancellation techniques

    Science.gov (United States)

    Wu, Hunter; Sealy, Kylee Devro; Sharp, Bryan Thomas; Gilchrist, Aaron

    2016-01-26

    A method and apparatus for LCL resonant converter control utilizing Asymmetric Voltage Cancellation is described. The methods to determine the optimal trajectory of the control variables are discussed. Practical implementations of sensing load parameters are included. Simple PI, PID and fuzzy logic controllers are included with AVC for achieving good transient response characteristics with output current regulation.

  7. Liquid Fluoride Salt Experimentation Using a Small Natural Circulation Cell

    Energy Technology Data Exchange (ETDEWEB)

    Yoder Jr, Graydon L [ORNL; Heatherly, Dennis Wayne [ORNL; Williams, David F [ORNL; Elkassabgi, Yousri M. [Texas A& M University, Kingsville; Caja, Joseph [Electrochemical Systems, Inc.; Caja, Mario [ORNL; Jordan, John [Texas A& M University, Kingsville; Salinas, Roberto [Texas A& M University, Kingsville

    2014-04-01

    A small molten fluoride salt experiment has been constructed and tested to develop experimental techniques for application in liquid fluoride salt systems. There were five major objectives in developing this test apparatus: Allow visual observation of the salt during testing (how can lighting be introduced, how can pictures be taken, what can be seen) Determine if IR photography can be used to examine components submerged in the salt Determine if the experimental configuration provides salt velocity sufficient for collection of corrosion data for future experimentation Determine if a laser Doppler velocimeter can be used to quantify salt velocities. Acquire natural circulation heat transfer data in fluoride salt at temperatures up to 700oC All of these objectives were successfully achieved during testing with the exception of the fourth: acquiring velocity data using the laser Doppler velocimeter. This paper describes the experiment and experimental techniques used, and presents data taken during natural circulation testing.

  8. Experimental apparatus and its operational characteristics for MHD rotating machine with superconducting rotor

    International Nuclear Information System (INIS)

    Katsurai, Makoto; Karasaki, Takashi; Sekiguchi, Tadashi; Matsuda, Shoji; Ichikawa, Hayao.

    1976-01-01

    This paper presents the construction and operational characteristics of the experimental apparatus of MHD rotating machine with superconducting rotor, which has the electromechanical energy conversion function based on the inductive interactions between travelling magnetic field produced by the rotor and MHD working fluid. The machine consists of a rotating-dewar type superconducting rotor and a coaxially rotating metal cylinder which simulates the liquid metal MHD working fluid, and the both of them are driven separately by speed-controlled driving motors. The superconducting magnets installed in the rotor has the 8 shaped winding whose outer diameter is 11 cm and hight is 11 cm, and with the excitation current of 200 A (rating), it produces screw type magnetic field in the inductive interaction region of the cylinder with the peak value of 0.2 Wb/m 2 , whereas the average field strength reaches almost 4 Wb/m 2 inside the winding. In this condition, mutual interaction force is 30 N in the peripheral direction and 8 N in the axial direction and the total driving power of motors is 1,300 W when the relative rotation speed of the rotor and the cylinder is 800 rpm. Observed characteristics of this machine are for the most part in agreement with those estimated by the theoretical analysis. (auth.)

  9. Improved cold neutron radiographic apparatus and method

    International Nuclear Information System (INIS)

    1981-01-01

    An improved cold neutron radiography technique is described in which the neutron temperature is matched to the specific material to be analyzed. In addition to a beam source and detector the apparatus incorporates a cryogenic refrigerator which enables the moderator material to be cooled to a predetermined adjustable temperature below the Bragg edge temperature of the sample. (U.K.)

  10. Electroless plating apparatus for discrete microsized particles

    International Nuclear Information System (INIS)

    Mayer, A.

    1978-01-01

    Method and apparatus are disclosed for producing very uniform coatings of a desired material on discrete microsized particles by electroless techniques. Agglomeration or bridging of the particles during the deposition process is prevented by imparting a sufficiently random motion to the particles that they are not in contact with each other for a time sufficient for such to occur

  11. Borehole sealing method and apparatus

    International Nuclear Information System (INIS)

    Hartley, J.N.; Jansen, G. Jr.

    1977-01-01

    A method and apparatus is described for sealing boreholes in the earth. The borehole is blocked at the sealing level, and a sealing apparatus capable of melting rock and earth is positioned in the borehole just above seal level. The apparatus is heated to rock-melting temperature and powdered rock or other sealing material is transported down the borehole to the apparatus where it is melted, pooling on the mechanical block and allowed to cool and solidify, sealing the hole. Any length of the borehole can be sealed by slowly raising the apparatus in the borehole while continuously supplying powdered rock to the apparatus to be melted and added to the top of the column of molten and cooling rock, forming a continuous borehole seal. The sealing apparatus consists of a heater capable of melting rock, including means for supplying power to the heater, means for transporting powdered rock down the borehole to the heater, means for cooling the apparatus and means for positioning the apparatus in the borehole. 5 claims, 1 figure

  12. Ion beam exposure apparatus using a liquid metal source

    International Nuclear Information System (INIS)

    Komuro, M.

    1982-01-01

    A field effect liquid metal ion source is described. The current-voltage characteristics, the angular intensity distribution and the total energy distribution were measured for gallium, gold and lead sources. The results are presented and the effect of space charge on the emission current is discussed. Optimum working conditions for the use of the ion sources in probe formation are derived. On the basis of the experimental results, an apparatus operating at 50 kV or less was designed. Details of the design, which includes a triode ion gun and an einzel lens, are given together with preliminary results of pattern delineation with the apparatus. (Auth.)

  13. Apparatus for drying sugar cubes

    NARCIS (Netherlands)

    Derckx, H.A.J.; Torringa, H.M.

    1999-01-01

    Device for drying sugar cubes containing a heating apparatus for heating and dehumidifying the sugar cubes, a conditioning apparatus for cooling off and possibly further dehumidifying the sugar cubes and a conveying apparatus for conveying the sugar cubes through the heating apparatus and the

  14. The ATHENA Antihydrogen Apparatus

    CERN Document Server

    Amoretti, M; Bonomi, G; Bouchta, A; Bowe, P; Carraro, C; Charlton, M; Collier, M; Doser, Michael; Filippini, V; Fine, K S; Fontana, A; Fujiwara, M C; Funakoshi, R; Genova, P; Glauser, A; Grögler, D; Hangst, Jeffrey S; Hayano, R S; Higaki, H; Holzscheiter, Michael H; Joffrain, W; Jørgensen, L V; Lagomarsino, V; Landua, Rolf; Cesar, C L; Lindelöf, D; Lodi-Rizzini, E; Macri, M; Madsen, N; Manuzio, D; Manuzio, G; Marchesotti, M; Montagna, P; Pruys, H S; Regenfus, C; Riedler, P; Rochet, J; Rotondi, A; Rouleau, G; Testera, G; Van der Werf, D P; Variola, A; Watson, T L; Yamazaki, T; Yamazaki, Y

    2004-01-01

    The ATHENA apparatus that recently produced and detected the first cold antihydrogen atoms is described. Its main features, which are described herein, are: an external positron accumulator, making it possible to accumulate large numbers of positrons; a separate antiproton catching trap, optimizing the catching, colling and handling of antiprotons: a unique high resolution antihydrogen annihilation detector, allowing a clear determination that antihydrogen has been produced; an open, modular design making variations in the experimental approach possible and a "nested" Penning trap situated in a cryogenic, 3T magnetic field environment used for the mixing of the antiprotons and positrons.

  15. Training apparatus

    International Nuclear Information System (INIS)

    Monteith, W.D.

    1983-01-01

    Training apparatus for use in contamination surveillance uses a mathematical model of a hypothetical contamination source (e.g. nuclear, bacteriological or chemical explosion or leak) to determine from input data defining the contamination source, the contamination level at any location within a defined exercise area. The contamination level to be displayed by the apparatus is corrected to real time from a real time clock or may be displayed in response to a time input from a keyboard. In a preferred embodiment the location is defined by entering UTM grid reference coordinates using the keyboard. The mathematical model used by a microprocessor of the apparatus for simulation of contamination levels in the event of a nuclear explosion is described. (author)

  16. Pore roller filtration apparatus

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to the field of filtering, more precisely the present invention concerns an apparatus and a method for the separation of dry matter from a medium and the use of said apparatus. One embodiment discloses an apparatus for the separation of dry matter from a medium, comp...

  17. Electro-optical and Magneto-optical Sensing Apparatus and Method for Characterizing Free-space Electromagnetic Radiation

    Science.gov (United States)

    Zhang, Xi-Cheng; Riordan, Jenifer Ann; Sun, Feng-Guo

    2000-08-29

    Apparatus and methods for characterizing free-space electromagnetic energy, and in particular, apparatus/method suitable for real-time two-dimensional far-infrared imaging applications are presented. The sensing technique is based on a non-linear coupling between a low-frequency electric (or magnetic) field and a laser beam in an electro-optic (or magnetic-optic) crystal. In addition to a practical counter-propagating sensing technique, a co-linear approach is described which provides longer radiated field-optical beam interaction length, thereby making imaging applications practical.

  18. Loading technique for dynamic response studies of geological materials

    International Nuclear Information System (INIS)

    Butler, R.I.; Forrestal, M.J.

    1979-04-01

    A loading technique to study the dynamic response of tuff was explored. Loading is provided by electrically exploding etched copper mesh patterns with current from a capacitor discharge. Pressure pulses with peak pressures up to 1.25 kbar and 0.10 to 0.20 ms durations were measured with a pressure bar. The upper value of peak pressure was limited by the strength of the experimental apparatus, and higher pressure generation is possible with a redesign of test hardware. 6 figures, 2 tables

  19. Microelectromechanical acceleration-sensing apparatus

    Science.gov (United States)

    Lee, Robb M [Albuquerque, NM; Shul, Randy J [Albuquerque, NM; Polosky, Marc A [Albuquerque, NM; Hoke, Darren A [Albuquerque, NM; Vernon, George E [Rio Rancho, NM

    2006-12-12

    An acceleration-sensing apparatus is disclosed which includes a moveable shuttle (i.e. a suspended mass) and a latch for capturing and holding the shuttle when an acceleration event is sensed above a predetermined threshold level. The acceleration-sensing apparatus provides a switch closure upon sensing the acceleration event and remains latched in place thereafter. Examples of the acceleration-sensing apparatus are provided which are responsive to an acceleration component in a single direction (i.e. a single-sided device) or to two oppositely-directed acceleration components (i.e. a dual-sided device). A two-stage acceleration-sensing apparatus is also disclosed which can sense two acceleration events separated in time. The acceleration-sensing apparatus of the present invention has applications, for example, in an automotive airbag deployment system.

  20. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  1. Apparatus for Crossflow Filtration Testing of High Level Waste Samples

    International Nuclear Information System (INIS)

    Nash, C.

    1998-05-01

    Remotely-operated experimental apparatuses for verifying crossflow filtration of high level nuclear waste have been constructed at the Savannah River Site (SRS). These units have been used to demonstrate filtration processes at the Savannah River Site, Oak Ridge National Laboratory, the Idaho National Engineering and Environmental Laboratory, and Pacific Northwest National Laboratory. The current work covers the design considerations for experimentation as well as providing results from testing at SRS

  2. Mirror plasma apparatus

    International Nuclear Information System (INIS)

    Moir, R.W.

    1981-01-01

    A mirror plasma apparatus which utilizes shielding by arc discharge to form a blanket plasma and lithium walls to reduce neutron damage to the wall of the apparatus. An embodiment involves a rotating liquid lithium blanket for a tandem mirror plasma apparatus wherein the first wall of the central mirror cell is made of liquid lithium which is spun with angular velocity great enough to keep the liquid lithium against the first material wall, a blanket plasma preventing the lithium vapor from contaminating the plasma

  3. Water intake fish diversion apparatus

    International Nuclear Information System (INIS)

    Taft, E.P. III; Cook, T.C.

    1995-01-01

    A fish diversion apparatus uses a plane screen to divert fish for variety of types of water intakes in order to protect fish from injury and death. The apparatus permits selection of a relatively small screen angle, for example ten degrees, to minimize fish injury. The apparatus permits selection of a high water velocity, for example ten feet per second, to maximize power generation efficiency. The apparatus is especially suitable retrofit to existing water intakes. The apparatus is modular to allow use plural modules in parallel to adjust for water flow conditions. The apparatus has a floor, two opposite side walls, and a roof which define a water flow passage and a plane screen within the passage. The screen is oriented to divert fish into a fish bypass which carries fish to a safe discharge location. The dimensions of the floor, walls, and roof are selected to define the dimensions of the passage and to permit selection of the screen angle. The floor is bi-level with a level upstream of the screen and a level beneath screen selected to provide a uniform flow distribution through the screen. The apparatus may include separation walls to provide a water flow channel between the apparatus and the water intake. Lead walls may be used to adjust water flow conditions into the apparatus. The apparatus features stoplog guides near its upstream and downstream ends to permit the water flow passage to be dewatered. 3 figs

  4. Experimental methods in radioactive ion-beam target/ion source development and characterization

    International Nuclear Information System (INIS)

    Welton, R.F.; Alton, G.D.; Cui, B.; Murray, S.N.

    1998-01-01

    We have developed off-line experimental techniques and apparatuses that permit direct measurement of effusive-flow delay times and ionization efficiencies for nearly any chemically reactive element in high-temperature target/ion sources (TIS) commonly used for on-line radioactive ion-beam (RIB) generation. The apparatuses include a hot Ta valve for effusive-flow delay-time measurements, a cooled molecular injection system for determination of ionization efficiencies, and a gas flow measurement/control system for introducing very low, well-defined molecular flows into the TIS. Measurements are performed on a test stand using molecular feed compounds containing stable complements of the radioactive nuclei of interest delivered to the TIS at flow rates commensurate with on-line RIB generation. In this article, the general techniques are described and effusive-flow delay times and ionization efficiency measurements are reported for fluorine in an electron-beam plasma target/ion source developed for RIB generation and operated in both positive- and negative-ion extraction modes. copyright 1998 American Institute of Physics

  5. Application of the zone-melting technique to metal chelate systems-VI A new apparatus for zone-melting chromatography.

    Science.gov (United States)

    Maeda, S; Kobayashi, H; Ueno, K

    1973-07-01

    An improved apparatus has been constructed for zone-melting chromatography. An essential feature of the apparatus is that the length of the molten zone can be kept constant during a zone-melting operation, by employing heating and cooling compartments which are separated from each other by double partition plates. Each compartment is heated or cooled with jets of hot or cold air. The apparatus is suitable for organic materials melting in the range between 40 degrees and 180 degrees . The distribution of metal ion along the column after zone melting of copper acetylacetonate in 2-methoxynaphthalene was a smooth curve. The plot of the position of maximum concentration, x(max), against the number of zone passes, n, gave a relationship in accordance with theoretical prediction.

  6. Light shielding apparatus

    Science.gov (United States)

    Miller, Richard Dean; Thom, Robert Anthony

    2017-10-10

    A light shielding apparatus for blocking light from reaching an electronic device, the light shielding apparatus including left and right support assemblies, a cross member, and an opaque shroud. The support assemblies each include primary support structure, a mounting element for removably connecting the apparatus to the electronic device, and a support member depending from the primary support structure for retaining the apparatus in an upright orientation. The cross member couples the left and right support assemblies together and spaces them apart according to the size and shape of the electronic device. The shroud may be removably and adjustably connectable to the left and right support assemblies and configured to take a cylindrical dome shape so as to form a central space covered from above. The opaque shroud prevents light from entering the central space and contacting sensitive elements of the electronic device.

  7. Design of neutral particle incident heating apparatus for large scale helical apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Osamu; Oka, Yoshihide; Osakabe, Masaki; Takeiri, Yasuhiko; Tsumori, Katsuyoshi; Akiyama, Ryuichi; Asano, Eiji; Kawamoto, Toshikazu; Kuroda, Tsutomu [National Inst. for Fusion Science, Nagoya (Japan)

    1997-02-01

    In the Institute of Nuclear Fusion Science, construction of the large scale helical apparatus has been progressed favorably, and constructions of the heating apparatus as well as of electron resonance apparatus were begun in their orders under predetermined manner since 1994 fiscal year. And, on 1995 fiscal year, construction of neutral particle incident heating apparatus, leading heat apparatus, was begun under 3 years planning. The plasma heating study system adopted the study results developed in this institute through the large scale hydrogen negative ion source and also adopted thereafter development on nuclear fusion study by modifying the original specification set at the beginning of the research plan before 7 years. As a result, system design was changed from initial 125 KeV to 180 KeV in the beam energy and to execute 15 MW incidence using two sets beam lines, to begin its manufacturing. Here is described on its new design with reason of its modifications. (G.K.)

  8. Apparatus for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Chen, C-H.; Tsay, H-M.; Heyer, R.E.

    1979-01-01

    Apparatus for solid-phase antibody separation techniques used in radioimmunoassays is described in this invention. It consists of a rectangular prism tray with multiple wells protruding into its interior from one side. Near the base of the tray is an orifice used for creating evacuated condition within the structure. At the base of each well there is an orifice of such size and shape as to retain an aqueous liquid under given pressure conditions but permit the evacuation of this liquid at reduced pressure. The outlet of these orifices is in the shape of an inverted conical frustrum. Each of the wells contains an antibody coated disc of porous cellulose paper surrounded by a plastic support. The porous nature of the cellulose paper ensures contact between the antibody coating and the antigen. The use of antibody coated porous cellulose paper in combination with the vacuum operated apparatus simplifies the manipulative steps whilst still maintaining the sensitivity of the radioimmunoassay. It also obviates the need for aspiration and thus lessens the risk of contamination from one sample to another. (UK)

  9. Gamma apparatuses for radiotherapy

    International Nuclear Information System (INIS)

    Sul'kin, A.G.

    1986-01-01

    Scientific and technical achievements in development and application of gamma therapeutic apparatuses for external and intracavity irradiations are generalized. Radiation-physical parameters of apparatuses providing usability of progressive methods in radiotherapy of onclogical patients are given. Optimization of main apparatus elements, ensurance of its operation reliability, reduction of errors of irradiation plan reproduction are considered. Attention is paid to radiation safety

  10. Experimental data processing techniques by a personal computer

    International Nuclear Information System (INIS)

    Matsuura, Kiyokata; Tsuda, Kenzo; Abe, Yoshihiko; Kojima, Tsuyoshi; Nishikawa, Akira; Shimura, Hitoshi; Hyodo, Hiromi; Yamagishi, Shigeru.

    1989-01-01

    A personal computer (16-bit, about 1 MB memory) can be used at a low cost in the experimental data processing. This report surveys the important techniques on A/D and D/A conversion, display, store and transfer of the experimental data. It is also discussed the items to be considered in the software. Practical softwares programed BASIC and Assembler language are given as examples. Here, we present some techniques to get faster process in BASIC language and show that the system composed of BASIC and Assembler is useful in a practical experiment. The system performance such as processing speed and flexibility in setting operation condition will depend strongly on programming language. We have made test for processing speed by some typical programming languages; BASIC(interpreter), C, FORTRAN and Assembler. As for the calculation, FORTRAN has the best performance which is comparable to or better than Assembler even in the personal computer. (author)

  11. Experimental techniques in nuclear and particle physics

    CERN Document Server

    Tavernier, Stefaan

    2009-01-01

    The book is based on a course in nuclear and particle physics that the author has taught over many years to physics students, students in nuclear engineering and students in biomedical engineering. It provides the basic understanding that any student or researcher using such instruments and techniques should have about the subject. After an introduction to the structure of matter at the subatomic scale, it covers the experimental aspects of nuclear and particle physics. Ideally complementing a theoretically-oriented textbook on nuclear physics and/or particle physics, it introduces the reader to the different techniques used in nuclear and particle physics to accelerate particles and to measurement techniques (detectors) in nuclear and particle physics. The main subjects treated are: interactions of subatomic particles in matter; particle accelerators; basics of different types of detectors; and nuclear electronics. The book will be of interest to undergraduates, graduates and researchers in both particle and...

  12. Experimental and numerical analysis of water hammer in a large-scale PVC pipeline apparatus

    NARCIS (Netherlands)

    Bergant, A.; Hou, Q.; Keramat, A.; Tijsseling, A.S.; Gajic, A.; Benisek, M.; Nedeljkovic, M.

    2011-01-01

    This paper investigates the effects of the pipe-wall viscoelasticity on water-hammer pressures. A large-scale pipeline apparatus made of polyvinyl chloride (PVC) at Deltares, Delft, The Netherlands, has been used to carry out waterhammer experiments. Tests have been conducted in a

  13. An experimental evaluation of a new designed apparatus (NDA) for the rapid measurement of impaired motor function in rats.

    Science.gov (United States)

    Jarrahi, M; Sedighi Moghadam, B; Torkmandi, H

    2015-08-15

    Assessment of the ability of rat to balance by rotarod apparatus (ROTA) is frequently used as a measure of impaired motor system function. Most of these methods have some disadvantages, such as failing to sense motor coordination rather than endurance and as the sensitivity of the method is low, more animals are needed to obtain statistically significant results. We have designed and tested a new designed apparatus (NDA) to measure motor system function in rats. Our system consists of a glass box containing 4 beams which placed with 1cm distance between them, two electrical motors for rotating the beams, and a camera to record the movements of the rats. The RPM of the beams is adjustable digitally between 0 and 50 rounds per minute. We evaluated experimentally the capability of the NDA for the rapid measurement of impaired motor function in rats. Also we demonstrated that the sensitivity of the NDA increases by faster rotation speeds and may be more sensitive than ROTA for evaluating of impaired motor system function. Compared to a previous version of this task, our NDA provides a more efficient method to test rodents for studies of motor system function after impaired motor nervous system. In summary, our NDA will allow high efficient monitoring of rat motor system function and may be more sensitive than ROTA for evaluating of impaired motor system function in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Immunoperoxidase technique in experimental chronic chagasic myocarditis

    Directory of Open Access Journals (Sweden)

    M.d. Maria Celina Morales

    1987-04-01

    Full Text Available Chagas'disease has been described as the commonest form of chronic myocarditis. An immunologic pathogenesis has been discribed for this form of the disease. So far, no immunoperoxidase technique has been used for the detection of immunological deposits in chronic experimental Chagas'myocardiopathy. Forty-one Swiss mice, three months old were inoculated intraperitoneally with doses between 10 and 10(5 Tulahuen trypomastigotes. Mice were reinoculated one month after with doses between 10² and 10(5 and sacrificed at 6 (n=21 and 9 months (n=9 after the first inoculation. ECGs were recorded before sacrifice. Immunoperoxidase technique (peroxidase-antiperoxidase method, immunofluorescence (direct and indirect as well as histological studies were performed in myocardiums and skeletal muscles of the surviving animals. The most sensitive methods for detecting chronic chagasic infection were the routine histologic studies (73% and the ECGs 83% and 89% on 6 and 9 mo. post-infected mice, respectively. Myocardial involvement varied from interstitial mild focal lymphocyte infiltrates up to replacement of myocytes by loose connective tissue. Atrial myocardiums (21/23, 91% were more affected than ventricles (9/23, 39%. Typical chagasic nests were rarely found. Skeletal muscle involvement (11/18 and 7/9 varied from mild to extensive lymphocyte and plasmacell infiltrates, and necrotic fibers. The involved antigen were shown in skeletal muscles by the immunoperoxidase technique as diffusely arranged granular intracytoplasmatic deposit for both IgC and total immunoglobulins. The coincidence between this technique and histologic muscle lesions was 11/18 (61(% in 6 mo. and 6/8 (75% at 9 mo. post-infection. In heart, delicate granular deposits of total immunoglobulins were seen diffusely arranged within the ventricular myocytes; coincidence between immunoperoxidase technique anl histologic involvement increased from 36 to 66% in animals sacrifeced 6 and 9 mo. post

  15. Apparatus bias and place conditioning with ethanol in mice.

    Science.gov (United States)

    Cunningham, Christopher L; Ferree, Nikole K; Howard, MacKenzie A

    2003-12-01

    Although the distinction between "biased" and "unbiased" is generally recognized as an important methodological issue in place conditioning, previous studies have not adequately addressed the distinction between a biased/unbiased apparatus and a biased/unbiased stimulus assignment procedure. Moreover, a review of the recent literature indicates that many reports (70% of 76 papers published in 2001) fail to provide adequate information about apparatus bias. This issue is important because the mechanisms underlying a drug's effect in the place-conditioning procedure may differ depending on whether the apparatus is biased or unbiased. The present studies were designed to assess the impact of apparatus bias and stimulus assignment procedure on ethanol-induced place conditioning in mice (DBA/2 J). A secondary goal was to compare various dependent variables commonly used to index conditioned place preference. Apparatus bias was manipulated by varying the combination of tactile (floor) cues available during preference tests. Experiment 1 used an unbiased apparatus in which the stimulus alternatives were equally preferred during a pre-test as indicated by the group average. Experiment 2 used a biased apparatus in which one of the stimuli was strongly preferred by most mice (mean % time on cue = 67%) during the pre-test. In both studies, the stimulus paired with drug (CS+) was assigned randomly (i.e., an "unbiased" stimulus assignment procedure). Experimental mice received four pairings of CS+ with ethanol (2 g/kg, i.p.) and four pairings of the alternative stimulus (CS-) with saline; control mice received saline on both types of trial. Each experiment concluded with a 60-min choice test. With the unbiased apparatus (experiment 1), significant place conditioning was obtained regardless of whether drug was paired with the subject's initially preferred or non-preferred stimulus. However, with the biased apparatus (experiment 2), place conditioning was apparent only when

  16. Assessment of disintegration of rapidly disintegrating tablets by a visiometric liquid jet-mediated disintegration apparatus.

    Science.gov (United States)

    Desai, Parind M; Liew, Celine V; Heng, Paul W S

    2013-02-14

    The aim of this study was to develop a responsive disintegration test apparatus that is particularly suitable for rapidly disintegrating tablets (RDTs). The designed RDT disintegration apparatus consisted of disintegration compartment, stereomicroscope and high speed video camera. Computational fluid dynamics (CFD) was used to simulate 3 different designs of the compartment and to predict velocity and pressure patterns inside the compartment. The CFD preprocessor established the compartment models and the CFD solver determined the numerical solutions of the governing equations that described disintegration medium flow. Simulation was validated by good agreement between CFD and experimental results. Based on the results, the most suitable disintegration compartment was selected. Six types of commercial RDTs were used and disintegration times of these tablets were determined using the designed RDT disintegration apparatus and the USP disintegration apparatus. The results obtained using the designed apparatus correlated well to those obtained by the USP apparatus. Thus, the applied CFD approach had the potential to predict the fluid hydrodynamics for the design of optimal disintegration apparatus. The designed visiometric liquid jet-mediated disintegration apparatus for RDT provided efficient and precise determination of very short disintegration times of rapidly disintegrating dosage forms. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Operation and maintenance manuals for VEGA apparatus on radionuclide release from irradiated fuel

    International Nuclear Information System (INIS)

    Hayashida, Retsu; Hidaka, Akihide; Nakamura, Takehiko; Kudo, Tamotsu; Ohtomo, Takashi; Uetsuka, Hiroshi

    2001-03-01

    An experimental program, Verification Experiments of radionuclides Gas/Aerosol release (VEGA), was initiated at JAERI from September 1999 to improve source term predictabilities for hypothetical severe accidents. In the experiment, a short fuel segment taken from LWR fuels irradiated in Japanese power reactors is inductively heated to high temperatures (∼3273K) in a hot cell under high pressure conditions up to 1.0MPa. Particularly, a focus will be placed on the release and transport behaviors of low-volatile fission products (FP), actinides and short-life FP which have not been well investigated in previous studies. This experimental apparatus was completed in February 1999 and three experiments were performed by the end of 2000. Most of these experiments were successfully conducted, but some problems were also found. Especially, in the first VEGA-1 test with the purpose of shakedown and reference data acquisition, there were problems such as flow blockage at the outlet of furnace due to structure melting, malfunction of heaters and so on. Therefore, the design for these defective parts was changed for future experiments. Moreover, the apparatus is not so big but the entire processes are very complicated. Accordingly, the operators should well understand the details of the apparatus including the recent change of design. This report describes outlines of the VEGA apparatus and the procedures for operation and maintenance. (author)

  18. Bubble retention in synthetic sludge: Testing of alternative gas retention apparatus

    International Nuclear Information System (INIS)

    Rassat, S.D.; Gauglitz, P.A.

    1995-07-01

    Several of the underground storage tanks currently used to store waste at Hanford have been placed on the Flammable Gas Watch List, because the waste is either known or suspected to generate, store, and episodically release flammable gases. The objective of this experimental study is to develop a method to measure gas bubble retention in simulated tank waste and in diluted simulant. The method and apparatus should (1) allow for reasonably rapid experiments, (2) minimize sample disturbance, and (3) provide realistic bubble nucleation and growth. The scope of this experimental study is to build an apparatus for measuring gas retention in simulated waste and to design the apparatus to be compatible with future testing on actual waste. The approach employed for creating bubbles in sludge involves dissolving a soluble gas into the supernatant liquid at an elevated pressure, recirculating the liquid containing the dissolved gas through the sludge, then reducing the pressure to allow bubbles to nucleate and grow. Results have been obtained for ammonia as the soluble gas and SY1-SIM-91A, a chemically representative simulated tank waste. In addition, proof-of-principle experiments were conducted with both ammonia and CO 2 as soluble gases and sludge composed of 90-micron glass beads. Results are described

  19. Waste Water Treatment Apparatus and Methods

    Science.gov (United States)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2014-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  20. Construction of shallow land simulation apparatuses

    International Nuclear Information System (INIS)

    Yamamoto, Tadatoshi; Ohtsuka, Yoshiro; Takebe, Shinichi; Ohnuki, Toshihiko; Ogawa, Hiromichi; Harada, Yoshikane; Saitoh, Kazuaki; Wadachi, Yoshiki

    1984-07-01

    Shallow land simulation apparatuses in which natural soil can be used as testing soil have been constructed to investigate the migration characteristics of radionuclides in a disposal site. These apparatuses consist of aerated zone apparatus and aquifer zone one. In the aerated zone apparatus, aerated soil upon ground water level is contained in the soil column (d: 30cm x h: 120cm). In the aquifer zone apparatus, aquifer soil laying ground water level is contained in the soil vessel (b: 90cm x l: 270cm x h: 45cm). This report describes the outline of shallow land simulation apparatuses : function of apparatuses and specification of devices, analysis of obstructions, safety rules, analysis of accidents and operation manual. (author)

  1. Ultrasonic-resonator-combined apparatus for purifying nuclear aerosol particles

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Suxia; Zhang, Quanhu; Li, Sufen; Chen, Chen; Su, Xianghua [Xi' an Hi-Tech Institute, Xi' an (China)

    2017-12-15

    The radiation hazards of radionuclides in the air arising from the storage room of nuclear devices to the operators cannot be ignored. A new ultrasonic-resonator-combined method for purifying nuclear aerosol particles is introduced. To remove particles with diameters smaller than 0.3 μm, an ultrasonic chamber is induced to agglomerate these submicron particles. An apparatus which is used to purify the nuclear aerosol particles is described in the article. The apparatus consists of four main parts: two filtering systems, an ultrasonic chamber and a high-pressure electrostatic precipitator system. Finally, experimental results demonstrated the effectiveness of the implementation of the ultrasonic resonators. The feasibility of the method is proven by its application to the data analysis of the experiments.

  2. Measurements of relevant parameters in the formation of clathrate hydrates by a novel experimental apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Arca, S.; Di Profio, P.; Germani, R.; Savelli, G. [Perugia Univ., CEMIN, Perugia (Italy). Dept. of Chemistry

    2008-07-01

    There is a growing interest in understanding the thermodynamics and kinetics of clathrate hydrate formation. This paper presented a study that involved the design, construction, calibration, and testing of a new apparatus that could obtain as many parameters as possible in a single formation batch and that could measure unexplored clathrate hydrate parameters. The apparatus was capable of measuring equilibrium phases involving gaseous components. The paper described the conceptual design as well as the chamber, pressure line, temperature control, liquid addition line, and conductometric probe. The paper also discussed data acquisition, stirring, measurement examples, and internal illumination and video monitoring. It was concluded that refining measurements, particularly those concerning kinetic characterizations, is important in order to clarify several uncertain kinetic behaviors of clathrate hydrates. 6 refs., 16 figs.

  3. Intensification of Evaporation and Condensation Processes in Heat Exchange Apparatus

    Directory of Open Access Journals (Sweden)

    L. L. Vasiliev

    2005-01-01

    Full Text Available The paper describes proposed design solutions for an intensification of heat transfer in evaporation and condensation heat exchangers. Complex experimental research of heat and mass transfer processes in flat and round cross-section miniature heat pipes is carried out. Optimization, development, manufacturing and an experimental investigation of copper miniature heat pipes with sintered powder are executed. Investigation results of capillary-porous structure properties that are used in evaporation and condensation heat-exchange apparatus are presented.

  4. Large Rotor Test Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This test apparatus, when combined with the National Full-Scale Aerodynamics Complex, produces a thorough, full-scale test capability. The Large Rotor Test Apparatus...

  5. Conduit grinding apparatus

    Science.gov (United States)

    Nachbar, Henry D.; Korytkowski, Alfred S.

    1991-01-01

    A grinding apparatus for grinding the interior portion of a valve stem receiving area of a valve. The apparatus comprises a faceplate, a plurality of cams mounted to an interior face of the faceplate, a locking bolt to lock the faceplate at a predetermined position on the valve, a movable grinder and a guide tube for positioning an optical viewer proximate the area to be grinded. The apparatus can either be rotated about the valve for grinding an area of the inner diameter of a valve stem receiving area or locked at a predetermined position to grind a specific point in the receiving area.

  6. Immunoperoxidase technique in experimental chronic chagasic myocarditis

    OpenAIRE

    M.d. Maria Celina Morales; M.D. José Milei

    1987-01-01

    Chagas'disease has been described as the commonest form of chronic myocarditis. An immunologic pathogenesis has been discribed for this form of the disease. So far, no immunoperoxidase technique has been used for the detection of immunological deposits in chronic experimental Chagas'myocardiopathy. Forty-one Swiss mice, three months old were inoculated intraperitoneally with doses between 10 and 10(5) Tulahuen trypomastigotes. Mice were reinoculated one month after with doses between 10² and ...

  7. Pipework inspection apparatus

    International Nuclear Information System (INIS)

    Wrigglesworth, K.J.; Knowles, J.F.

    1987-01-01

    The patent concerns a pipework inspection apparatus, which is capable of negotiating bends in pipework. The apparatus comprises a TV camera system, which contains an optical section and an electronics section, which are connected by a flexible coupling. The system can be pulled or pushed along the bore of the pipework. (U.K.)

  8. A TECHNIQUE OF EXPERIMENTAL INVESTIGATIONS OF LINEAR IMPULSE ELECTROMECHANICAL CONVERTERS

    Directory of Open Access Journals (Sweden)

    V.F. Bolyukh

    2017-04-01

    Full Text Available Purpose. Development of a technique of experimental studies linear pulse electromechanical converters parameters, which are used as shock-power devices and electromechanical accelerators, and comparing the experimental results with the calculated indices obtained using the mathematical model. Methodology. Method of experimental investigations of linear electromechanical converter is that the electrical parameters are recorded simultaneously (inductor winding current and mechanical parameters characterizing the power and speed indicators of the joke with actuator. Power indicators are primarily important for shock-power devices, and high velocity - for electromechanical accelerators. Power indices were investigated using piezoelectric sensors, a system of strain sensors, pressure pulsation sensor and high-speed videorecording. Velocity indicators were investigated using a resistive movement sensor which allows to record character of the armature movement with actuating element in each moment. Results. The technique of experimental research, which is the simultaneous recording of electrical and mechanical power and velocity parameters of the linear electromechanical converter pulse, is developed. In the converter as a shock-power device power indicators are recorded using a piezoelectric transducer, strain sensors system, pressure pulsation sensor and high-speed video. The parameters of the inductor winding current pulse, the time lag of mechanical processes in relation to the time of occurrence of the inductor winding current, the average speed of the joke, the magnitude and momentum of electrodynamics forces acting on the plate strikes are experimentally determined. In the converter as an electromechanical accelerator velocity performance recorded using resistive displacement sensors. It is shown that electromechanical converter processes have complex spatial-temporal character. The experimental results are in good agreement with the calculated

  9. Remote welding and cutting techniques for fusion experimental reactors

    International Nuclear Information System (INIS)

    Onozuka, M.; Ishide, T.; Oda, Y.; Nagaoka, E.; Ue, K.; Kamei, H.

    1995-01-01

    Experimental investigation of the YAG laser cutting/welding and plasma gouging techniques has been conducted to examine their suitability for remote maintenance systems in future fusion experimental reactors. Using a hybrid beam coupling system, two laser beams of 500W and 740W powers were successfully combined to provide a 1,240W beam power. The combined laser was transmitted through the optical fiber for cutting and welding. The transmission loss for the beams is in the range of 13% to 14%, which is low. As for plasma gouging, the shallow gouging made a groove measuring 10 mm in width and 4 mm in depth on the stainless steel plates at a traversing speed of 75 cm/min, while the deep gouging made a groove of 12 mm in width and 7.5 mm in depth at a traversing speed of 50 cm/min. In addition, it was found that the shallow gouging did not leave byproducts from the material, providing a clean surface. Based on the findings, it is shown that the YAG laser cutting/welding and plasma gouging techniques can be us3ed for remote welding and cutting in future fusion experimental reactors

  10. Remote welding and cutting techniques for fusion experimental reactors

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M.; Ishide, T.; Oda, Y.; Nagaoka, E.; Ue, K.; Kamei, H. [Mitsubishi Heavy Industries, Ltd., Yokohama (Japan)

    1995-12-31

    Experimental investigation of the YAG laser cutting/welding and plasma gouging techniques has been conducted to examine their suitability for remote maintenance systems in future fusion experimental reactors. Using a hybrid beam coupling system, two laser beams of 500W and 740W powers were successfully combined to provide a 1,240W beam power. The combined laser was transmitted through the optical fiber for cutting and welding. The transmission loss for the beams is in the range of 13% to 14%, which is low. As for plasma gouging, the shallow gouging made a groove measuring 10 mm in width and 4 mm in depth on the stainless steel plates at a traversing speed of 75 cm/min, while the deep gouging made a groove of 12 mm in width and 7.5 mm in depth at a traversing speed of 50 cm/min. In addition, it was found that the shallow gouging did not leave byproducts from the material, providing a clean surface. Based on the findings, it is shown that the YAG laser cutting/welding and plasma gouging techniques can be us3ed for remote welding and cutting in future fusion experimental reactors.

  11. The development of human factors experimental evaluation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Bong Shick; Oh, In Suk; Cha, Kyung Ho; Lee, Hyun Chul; Park, Geun Ok; Cheon, Se Woo; Suh, Sang Moon

    1997-07-01

    New human factors issues, such as evaluation of information navigation, the consideration of operator characteristics, and operator performance assessment, related to the HMI design based on VDUs are being risen. Thus, in order to solve these human factors issues, this project aims to establish the experimental technologies including the techniques for experimental design, experimental measurement, data collection and analysis, and to develop ITF (Integrated Test Facility) suitable for the experiment of HMI design evaluation. For the establish of the experimental data analysis and evaluation methodologies, we developed as the following: (1) a paradigm for human factors experimentation including experimental designs, procedures, and data analysis. (2) the methods for the assessment of operator`s mental workload (3) DAEXESS (data analysis and experiment evaluation supporting system). Also, we have established a experiment execution technologies through the preliminary experiments, such as the suitability evaluation of information display on a LSDP, the evaluation of information display on a LSDP, the evaluation of computerized operation procedure and an experiment of advanced alarm system (ADIOS). Finally, we developed the ITF including human machine simulator, telemetry system, an eye tracking system, an audio/video data measurement system, and three dimensional micro behaviour analysis system. (author). 81 refs., 68 tabs., 73 figs.

  12. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  13. The construction and operation of an ion channelling apparatus

    International Nuclear Information System (INIS)

    Grimshaw, J. A.; Barrat, E.E.; Wilson, C.G.; Spooner, F.J.

    1975-12-01

    The ion channelling facility at the Royal Military College of Science Rutherford Laboratory is described. A detailed account is given of new apparatus installed on the beam line of the 2.5 MeV Van de Graaf accelerator. Emphasis is placed on the mechanical and electronic requirements of such a system for the attainment of the required experimental conditions for good channelling. (author)

  14. Apparatus and method for pulsed laser deposition of materials on wires and pipes

    Science.gov (United States)

    Fernandez, Felix E.

    2003-01-01

    Methods and apparatuses are disclosed which allow uniform coatings to be applied by pulsed laser deposition (PLD) on inner and outer surfaces of cylindrical objects, such as rods, pipes, tubes, and wires. The use of PLD makes this technique particularly suitable for complex multicomponent materials, such as superconducting ceramics. Rigid objects of any length, i.e., pipes up to a few meters, and with diameters from less than 1 centimeter to over 10 centimeters can be coated using this technique. Further, deposition is effected simultaneously onto an annular region of the pipe wall. This particular arrangement simplifies the apparatus, reduces film uniformity control difficulties, and can result in faster operation cycles. In addition, flexible wires of any length can be continuously coated using the disclosed invention.

  15. Long-duration heat load measurement approach by novel apparatus design and highly efficient algorithm

    Science.gov (United States)

    Zhu, Yanwei; Yi, Fajun; Meng, Songhe; Zhuo, Lijun; Pan, Weizhen

    2017-11-01

    Improving the surface heat load measurement technique for vehicles in aerodynamic heating environments is imperative, regarding aspects of both the apparatus design and identification efficiency. A simple novel apparatus is designed for heat load identification, taking into account the lessons learned from several aerodynamic heating measurement devices. An inverse finite difference scheme (invFDM) for the apparatus is studied to identify its surface heat flux from the interior temperature measurements with high efficiency. A weighted piecewise regression filter is also proposed for temperature measurement prefiltering. Preliminary verification of the invFDM scheme and the filter is accomplished via numerical simulation experiments. Three specific pieces of apparatus have been concretely designed and fabricated using different sensing materials. The aerodynamic heating process is simulated by an inductively coupled plasma wind tunnel facility. The identification of surface temperature and heat flux from the temperature measurements is performed by invFDM. The results validate the high efficiency, reliability and feasibility of heat load measurements with different heat flux levels utilizing the designed apparatus and proposed method.

  16. Long-duration heat load measurement approach by novel apparatus design and highly efficient algorithm

    International Nuclear Information System (INIS)

    Zhu, Yanwei; Yi, Fajun; Meng, Songhe; Zhuo, Lijun; Pan, Weizhen

    2017-01-01

    Improving the surface heat load measurement technique for vehicles in aerodynamic heating environments is imperative, regarding aspects of both the apparatus design and identification efficiency. A simple novel apparatus is designed for heat load identification, taking into account the lessons learned from several aerodynamic heating measurement devices. An inverse finite difference scheme (invFDM) for the apparatus is studied to identify its surface heat flux from the interior temperature measurements with high efficiency. A weighted piecewise regression filter is also proposed for temperature measurement prefiltering. Preliminary verification of the invFDM scheme and the filter is accomplished via numerical simulation experiments. Three specific pieces of apparatus have been concretely designed and fabricated using different sensing materials. The aerodynamic heating process is simulated by an inductively coupled plasma wind tunnel facility. The identification of surface temperature and heat flux from the temperature measurements is performed by invFDM. The results validate the high efficiency, reliability and feasibility of heat load measurements with different heat flux levels utilizing the designed apparatus and proposed method. (paper)

  17. Inverse kinetics technique for reactor shutdown measurement: an experimental assessment. [AGR

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, T. A.; McDonald, D.

    1975-09-15

    It is proposed to use the Inverse Kinetics Technique to measure the subcritical reactivity as a function of time during the testing of the nitrogen injection systems on AGRs. A description is given of an experimental assessment of the technique by investigating known transients created by control rod movements on a small experimental reactor, (2m high, 1m radius). Spatial effects were observed close to the moving rods but otherwise derived reactivities were independent of detector position and agreed well with the existing calibrations. This prompted the suggestion that data from installed reactor instrumentation could be used to calibrate CAGR control rods.

  18. A simple apparatus for measuring the blood urea, manufactured by Dr. Luigj Benusi in 1943 in Albania.

    Science.gov (United States)

    Tartari, Flamur; Buzo, Stiliano; Vyshka, Gentian

    2009-01-01

    The apparatus invented by Dr. Luigj Benusi in 1943, in Tirana, was a practical application of the Kowarsky technique and Ambard laws, helping in determining blood urea levels and very important to a variety of diseases, mainly kidney disorders. The apparatus was invented and prepared from very simple laboratory materials, such as glasses, test tubes, corks and volumetric cylinders. Technologically, it was based upon the determination of blood urea through hypobromite, and, among the advantages of the apparatus of Benusi, were its extreme simplicity, the smaller amount of blood needed for producing results (2 milliliters), as well as an easiest way to clean up and to manage the apparatus from a practical point of everyday use.

  19. Comparison of experimental techniques for characterization of through-thickness texture variations

    DEFF Research Database (Denmark)

    Mishin, Oleg; Lauridsen, E.M.; Krieger Lassen, N.C.

    1999-01-01

    For the investigation of through-thickness texture gradients, a number of layers in rolled plates and sheets are inspected. Crystallographic textures in different layers can be characterized using several techniques. In the present work, traditional low-energy X-ray diffraction, the electron...... backscattering pattern technique in the scanning electron microscope and a novel technique which involves high energy synchrotron radiation are used for characterization of through-thickness texture variations in commercial purity cold-rolled aluminium. Important experimental aspects of these three techniques...

  20. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  1. TRANSFORMER APPARATUS

    Science.gov (United States)

    Wolfgang, F.; Nicol, J.

    1962-11-01

    Transformer apparatus is designed for measuring the amount of a paramagnetic substance dissolved or suspended in a diamagnetic liquid. The apparatus consists of a cluster of tubes, some of which are closed and have sealed within the diamagnetic substance without any of the paramagnetic material. The remaining tubes are open to flow of the mix- ture. Primary and secondary conductors are wrapped around the tubes in such a way as to cancel noise components and also to produce a differential signal on the secondaries based upon variations of the content of the paramagnetic material. (AEC)

  2. Radiotherapy apparatus

    International Nuclear Information System (INIS)

    Leung, P.M.; Webb, H.P.J.

    1985-01-01

    This invention relates to apparatus for applying intracavitary radiotherapy. In previously-known systems radioactive material is conveyed to a desired location within a patient by transporting a chain of balls pneumatically to and from an appropriately inserted applicator. According to this invention a ball chain for such a purpose comprises several radioactive balls separated by non-radioactive tracer balls of radiographically transparent material of lower density and surface hardness than the radioactive balls. The invention also extends to radiotherapy treatment apparatus comprising a storage, sorting and assembly system

  3. Apparatus for real-time acoustic imaging of Rayleigh-Bénard convection

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, Kerry, K.

    2008-10-28

    We have successfully designed, built and tested an experimental apparatus which is capable of providing the first real-time ultrasound images of Rayleigh-B\\'{e}nard convection in optically opaque fluids confined to large aspect ratio experimental cells. The apparatus employs a modified version of a commercially available ultrasound camera to capture images (30 frames per second) of flow patterns in a fluid undergoing Rayleigh Bénard convection. The apparatus was validated by observing convection rolls in 5cSt polydimethylsiloxane (PDMS) polymer fluid. Our first objective, after having built the apparatus, was to use it to study the sequence of transitions from diffusive to time--dependent heat transport in liquid mercury. The aim was to provide important information on pattern formation in the largely unexplored regime of very low Prandtl number fluids. Based on the theoretical stability diagram for liquid mercury, we anticipated that straight rolls should be stable over a range of Rayleigh numbers, between 1708 and approximately 1900. Though some of our power spectral densities were suggestive of the existence of weak convection, we have been unable to unambiguously visualize stable convection rolls above the theoretical onset of convection in liquid mercury. Currently, we are seeking ways to increase the sensitivity of our apparatus, such as (i) improving the acoustic impedance matching between our materials in the ultrasound path and (ii) reducing the noise level in our acoustic images due to turbulence and cavitation in the cooling fluids circulating above and below our experimental cell. If we are able to convincingly improve the sensitivity of our apparatus, and we still do not observe stable convection rolls in liquid mercury, then it may be the case that the theoretical stability diagram requires revision. In that case, either (i) straight rolls are not stable in a large aspect ratio cell at the Prandtl numbers associated with liquid mercury, or (ii

  4. The standardization of an apparatus for the mixing of soil samples ...

    African Journals Online (AJOL)

    Quantitative determination of nematode populations in soils frequently necessitates the mixing of representative soil samples to form a homogeneous, compound sample from which the nematodes are extracted. A mixing apparatus was developed and standardized with the aid of a spectrophotometric technique by which ...

  5. EXPERIMENTAL APPROVAL OF COMBINED FIXATION FOR FEMUR LENGTHENING

    Directory of Open Access Journals (Sweden)

    M. A. Stepanov

    2017-01-01

    Full Text Available Elimination of congenital shortening of lower limb still remains a complex and unsolved orthopaedic task which requires an improved fixation technique as well as adjusted tactics of treatment and rehabilitation procedures.Purpose of the study — experimental approval of femur lengthening technique by external fixation with Ilizarov apparatus and internal fixation by plate.Materials and methods. Femur lengthening was performed in 6 mongrel dogs. Average animal age was 1,5±0,3 years, average weight — 20±5 kg, femur length — 22±2 sm. External apparatus with two supports and a titanium plate of an original design were applied under general anesthesia on the right femur of animals. Lengthening was performed manually at a rate of1 mm per day in 4 stages at a distance of 10% from initial segment length. External apparatus was removed on the last day of distraction after locking the plate. X-ray examination was done on the day of surgery, in 7, 14 and 25 days from the onset of distraction as well as in 14, 30, 60 and 90 days after completion of distraction and removal of external apparatus. Three animals were taken out of experiment in 30 days of fixation, remaining three animals — in 90 days. After euthanasia the authors performed autopsy of the organic femur complex and tissues contacting the plate.Results. The use of operated limb was not restricted during the whole distraction period. The authors observed first roentgenological signs of distraction osteogenesis on 7th day of lengthening. By the end of distraction period, at 25th day, shadows of regenerates demonstrated longitudinal striated structures in all cases. Median lucency area of 1–5 mm was located diagonally and across the regenerate or was intermittent. In 60 days of fixation X-rays demonstrated homogeneous regenerate. External fixation index was 13,9±1,5 days/sm (p≤0,05. The authors observed no cases of implants fracture or deformity during the experiment

  6. Apparatus for Teaching Physics.

    Science.gov (United States)

    Gottlieb, Herbert H., Ed.

    1981-01-01

    Describes: (1) a variable inductor suitable for an inductance-capacitance bridge consisting of a fixed cylindrical solenoid and a moveable solenoid; (2) long-range apparatus for demonstrating falling bodies; and (3) an apparatus using two lasers to demonstrate ray optics. (SK)

  7. Advanced experimental and numerical techniques for cavitation erosion prediction

    CERN Document Server

    Chahine, Georges; Franc, Jean-Pierre; Karimi, Ayat

    2014-01-01

    This book provides a comprehensive treatment of the cavitation erosion phenomenon and state-of-the-art research in the field. It is divided into two parts. Part 1 consists of seven chapters, offering a wide range of computational and experimental approaches to cavitation erosion. It includes a general introduction to cavitation and cavitation erosion, a detailed description of facilities and measurement techniques commonly used in cavitation erosion studies, an extensive presentation of various stages of cavitation damage (including incubation and mass loss), and insights into the contribution of computational methods to the analysis of both fluid and material behavior. The proposed approach is based on a detailed description of impact loads generated by collapsing cavitation bubbles and a physical analysis of the material response to these loads. Part 2 is devoted to a selection of nine papers presented at the International Workshop on Advanced Experimental and Numerical Techniques for Cavitation Erosion (Gr...

  8. Playground Apparatus Experience and Muscular Endurance among Children 4-6.

    Science.gov (United States)

    Gabbard, Carl

    The effects of specific play apparatus experience on a test of upper body muscular endurance was investigated among a group of children 4-6 years old. Both the control and experimental group consisted of 45 subjects randomly selected on the basis of age from two private day care centers situated in the same community. The two groups were of…

  9. Radiation imaging apparatus

    International Nuclear Information System (INIS)

    1979-01-01

    This invention relates to a radiation imaging apparatus. It relates more particularly to apparatus of this general type which employs stationary X-ray source and detector arrays capable of acquiring multiple ultrafast scans per second to facilitate the dynamic study of moving human organs such as the beating heart. While the invention has many applications, it has particular utility in connection with computerized tomographic (CT) scanners. (Auth.)

  10. A Next-Generation Apparatus for Lithium Optical Lattice Experiments

    Science.gov (United States)

    Keshet, Aviv

    Quantum simulation is emerging as an ambitious and active subfield of atomic physics. This thesis describes progress towards the goal of simulating condensed matter systems, in particular the physics of the Fermi-Hubbard model, using ultracold Lithium atoms in an optical lattice. A major goal of the quantum simulation program is to observe phase transitions of the Hubbard model, into Neal antiferromagnetic phases and d-wave superfluid phases. Phase transitions are generally accompanied by a change in an underlying correlation in a physical system. Such correlations may be most amenable to probing by looking at fluctuations in the system. Experimental techniques for probing density and magnetization fluctuations in a variety of atomic Fermi systems are developed. The suppression of density fluctuations (or atom "shot noise") in an ideal degenerate Fermi gas is observed by absorption imaging of time-of-flight expanded clouds. In-trap measurements of density and magnetization fluctuations are not easy to probe with absorption imaging, due to their extremely high attenuation. A method to probe these fluctuations based on speckle patterns, caused by fluctuations in the index of refraction for a detuned illumination beam, is developed and applied first to weakly interacting and then to strongly interacting in-trap gases. Fluctuation probes such as these will be a crucial tool in future quantum simulation of condensed matter systems. The quantum simulation experiments that we want to perform require a complex sequence of precisely timed computer controlled events. A distributed GUI-based control system designed with such experiments in mind, The Cicero Word Generator, is described. The system makes use of a client-server separation between a user interface for sequence design and a set of output hardware servers. Output hardware servers are designed to use standard National Instruments output cards, but the client-server nature allows this to be extended to other output

  11. Safety measures for integrity test apparatus for IS process. Sulfuric acid decomposition section

    International Nuclear Information System (INIS)

    Noguchi, Hiroki; Kubo, Shinji; Iwatsuki, Jin; Onuki, Kaoru

    2013-07-01

    Hazardous substances such as sulfuric acid, sulfur dioxide and hydrogen iodide acid are employed in thermochemical Iodine-Sulfur (IS) process. It is necessary to take safety measure against workers and external environments to study experimentally on IS process. Presently we have been conducting to verify the soundness of main components made of engineering material in actual corrosive condition. An integrity test apparatus for the components of sulfuric acid decomposition was set up. We will use the hazardous substances such as sulfuric acid and sulfur dioxide and perform the experiment in pressurized condition in this integrity test. Safety measures for the test apparatus, operation and abnormal situation were considered prior to starting the test. This report summarized the consideration results for the safety measures on the integrity test apparatus for the components of sulfuric acid decomposition. (author)

  12. Experimental apparatus for overlapping a ground-state cooled ion with ultracold atoms

    Science.gov (United States)

    Meir, Ziv; Sikorsky, Tomas; Ben-shlomi, Ruti; Akerman, Nitzan; Pinkas, Meirav; Dallal, Yehonatan; Ozeri, Roee

    2018-03-01

    Experimental realizations of charged ions and neutral atoms in overlapping traps are gaining increasing interest due to their wide research application ranging from chemistry at the quantum level to quantum simulations of solid state systems. In this paper, we describe our experimental system in which we overlap a single ground-state cooled ion trapped in a linear Paul trap with a cloud of ultracold atoms such that both constituents are in the ?K regime. Excess micromotion (EMM) currently limits atom-ion interaction energy to the mK energy scale and above. We demonstrate spectroscopy methods and compensation techniques which characterize and reduce the ion's parasitic EMM energy to the ?K regime even for ion crystals of several ions. We further give a substantial review on the non-equilibrium dynamics which governs atom-ion systems. The non-equilibrium dynamics is manifested by a power law distribution of the ion's energy. We also give an overview on the coherent and non-coherent thermometry tools which can be used to characterize the ion's energy distribution after single to many atom-ion collisions.

  13. A portable X-ray diffraction apparatus for in situ analyses of masters' paintings

    Science.gov (United States)

    Eveno, Myriam; Duran, Adrian; Castaing, Jacques

    2010-09-01

    It is rare that the analyses of materials in paintings can be carried out by taking micro-samples. Valuable works of art are best studied in situ by non-invasive techniques. For that purpose, a portable X-ray diffraction and fluorescence apparatus has been designed and constructed at the C2RMF. This apparatus has been used for paintings of Rembrandt, Leonardo da Vinci, Van Gogh, Mantegna, etc. Results are given to illustrate the performance of X-ray diffraction, especially when X-ray fluorescence does not bring sufficient information to conclude.

  14. A portable X-ray diffraction apparatus for in situ analyses of masters' paintings

    International Nuclear Information System (INIS)

    Eveno, Myriam; Duran, Adrian; Castaing, Jacques

    2010-01-01

    It is rare that the analyses of materials in paintings can be carried out by taking micro-samples. Valuable works of art are best studied in situ by non-invasive techniques. For that purpose, a portable X-ray diffraction and fluorescence apparatus has been designed and constructed at the C2RMF. This apparatus has been used for paintings of Rembrandt, Leonardo da Vinci, Van Gogh, Mantegna, etc. Results are given to illustrate the performance of X-ray diffraction, especially when X-ray fluorescence does not bring sufficient information to conclude. (orig.)

  15. Apparatus for simultaneously measuring electrical conductivity and oxygen fugacity

    Energy Technology Data Exchange (ETDEWEB)

    Netherton, R.; Duba, A.

    1978-01-31

    Electrical conductivity studies of silicates are useful in determining temperature vs depth in the earth. Realistic laboratory measurements of conduction mechanisms require that exact determinations of oxygen fugacity (fo{sub 2}) be made in the experimental environment. An apparatus is described that monitors system fo{sub 2} with a calcia-doped zirconia-oxygen cell while measuring electrical conductivity of iron-bearing silicates at high temperature (greater than 1000 K). The fo{sub 2} calculated thermodynamically from CO/CO{sub 2} mixing ratios agreed well with measurements made with the zirconia cell at 1473 K, except for fo{sub 2} greater than 10{sup -4} Pa, where, on a log{sub 10} scale, mixing-ratio errors were as large as +- 0.2. These errors are attributed to oxygen contamination in the CO{sub 2} and to mobile carbon deposits that formed in the apparatus.

  16. The robustness of two tomography reconstructing techniques with heavily noisy dynamical experimental data from a high speed gamma-ray tomograph

    International Nuclear Information System (INIS)

    Vasconcelos, Geovane Vitor; Melo, Silvio de Barros; Dantas, Carlos Costa; Moreira, Icaro Malta; Johansen, Geira; Maad, Rachid

    2013-01-01

    The PSIRT (Particle Systems Iterative Reconstructive Technique) is, just like the ART method, an iterative tomographic reconstruction technique with the recommended use in the reconstruction of catalytic density distribution in the refining process of oil in the FCC-type riser. The PSIRT is based upon computer graphics' particle systems, where the reconstructing material is initially represented as composed of particles subject to a force field emanating from the beams, whose intensities are parameterized by the differences between the experimental readings of a given beam trajectory, and the values corresponding to the current amount of particles landed in this trajectory. A dynamical process is set as the beams fields of attracting forces dispute the particles. At the end, with the equilibrium established, the particles are replaced by the corresponding regions of pixels. The High Speed Gamma-ray Tomograph is a 5-source-fan-beam device with a 17-detector deck per source, capable of producing up to a thousand complete sinograms per second. Around 70.000 experimental sinograms from this tomograph were produced simulating the move of gas bubbles in different angular speeds immersed in oil within the vessel, through the use of a two-hole-polypropylene phantom. The sinogram frames were set with several different detector integration times. This article studies and compares the robustness of both ART and PSIRT methods in this heavily noisy scenario, where this noise comes not only from limitations in the dynamical sampling, but also from to the underlying apparatus that produces the counting in the tomograph. These experiments suggest that PSIRT is a more robust method than ART for noisy data. Visual inspection on the resulting images suggests that PSIRT is a more robust method than ART for noisy data, since it almost never presents globally scattered noise. (author)

  17. Sludge recovery apparatus

    International Nuclear Information System (INIS)

    Marmo, A.R.

    1979-01-01

    An improved design of a sludge recovery apparatus used in the fabrication of nuclear fuel is described. This apparatus provides for automatic separation of sludge from the grinder coolant, drying of the sludge into a flowable powder and transfer of the dry powder to a salvage container. It can be constructed to comply with criticality-safe-geometry requirements and to obviate need for operating personnel in its immediate vicinity. (UK)

  18. Versatile user-oriented atomic and molecular beam apparatus for use with the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Mitchell, J.B.A.; Grover, J.R.

    1978-11-01

    A proposed atomic and moleuclar beam apparatus is described for photon interaction studies using the National Sychrotron Light Source at the Brookhaven National Laboratory. This apparatus will employ ultrahigh vacuum techniques compatible with storage ring operation. Supersonic nozzle sources will be used to produce the beams and signal detection will be accomplished using a quadrupole mass analysis system. The equipment is intended for use both by in-house and outside users and primary consideration has been given to flexibility of design. The application of photoionization techniques to the study of crossed beam reactive scattering with particular emphasis on internal energy distribution analysis is discussed

  19. Safety considerations for continuous hydrogen production test apparatus with capacity of 50 N-litter hydrogen per hour

    International Nuclear Information System (INIS)

    Onuki, Kaoru; Akino, Norio; Shimizu, Saburo; Nakajima, Hayato; Higashi, Shunichi; Kubo, Shinji

    2001-03-01

    Since the thermochemical hydrogen production Iodine-Sulfur process decomposes water into hydrogen and oxygen using toxic chemicals such as sulfuric acid, iodine and hydriodic acid, safety considerations are very important in its research and development. Therefore, before construction of continuous hydrogen production test apparatus with capacity of 50 N-litter hydrogen per hour, comprehensive safety considerations were carried out to examine the design and construction works of the test apparatus, and the experimental plans using the apparatus. Emphasis was given on the safety considerations on prevention of breakage of glasswares and presumable abnormalities, accidents and their countermeasures. This report summarizes the results of the considerations. (author)

  20. Apparatuses And Systems For Embedded Thermoelectric Generators

    KAUST Repository

    Hussain, Muhammad M.; Inayat, Salman Bin; Smith, Casey Eben

    2013-01-01

    An apparatus and a system for embedded thermoelectric generators are disclosed. In one embodiment, the apparatus is embedded in an interface where the ambient temperatures on two sides of the interface are different. In one embodiment, the apparatus is fabricated with the interface in integrity as a unitary piece. In one embodiment, the apparatus includes a first thermoelectric material embedded through the interface. The apparatus further includes a second thermoelectric material embedded through the interface. The first thermoelectric material is electrically coupled to the second thermoelectric material. In one embodiment, the apparatus further includes an output structure coupled to the first thermoelectric material and the second thermoelectric material and configured to output a voltage.

  1. Apparatuses And Systems For Embedded Thermoelectric Generators

    KAUST Repository

    Hussain, Muhammad M.

    2013-08-08

    An apparatus and a system for embedded thermoelectric generators are disclosed. In one embodiment, the apparatus is embedded in an interface where the ambient temperatures on two sides of the interface are different. In one embodiment, the apparatus is fabricated with the interface in integrity as a unitary piece. In one embodiment, the apparatus includes a first thermoelectric material embedded through the interface. The apparatus further includes a second thermoelectric material embedded through the interface. The first thermoelectric material is electrically coupled to the second thermoelectric material. In one embodiment, the apparatus further includes an output structure coupled to the first thermoelectric material and the second thermoelectric material and configured to output a voltage.

  2. CASTING METHOD AND APPARATUS

    Science.gov (United States)

    Gray, C.F.; Thompson, R.H.

    1958-10-01

    An improved apparatus for the melting and casting of uranium is described. A vacuum chamber is positioned over the casting mold and connected thereto, and a rod to pierce the oxide skin of the molten uranium is fitted into the bottom of the melting chamber. The entire apparatus is surrounded by a jacket, and operations are conducted under a vacuum. The improvement in this apparatus lies in the fact that the top of the melting chamber is fitted with a plunger which allows squeezing of the oxide skin to force out any molten uranium remaining after the skin has been broken and the molten charge has been cast.

  3. Apparatus and test method for characterizing the temperature regulating properties of thermal functional porous polymeric materials.

    Science.gov (United States)

    Yao, Bao-Guo; Zhang, Shan; Zhang, De-Pin

    2017-05-01

    In order to evaluate the temperature regulating properties of thermal functional porous polymeric materials such as fabrics treated with phase change material microcapsules, a new apparatus was developed. The apparatus and the test method can measure the heat flux, temperature, and displacement signals during the dynamic contact and then quickly give an evaluation for the temperature regulating properties by simulating the dynamic heat transfer and temperature regulating process when the materials contact the body skin. A series of indices including the psychosensory intensity, regulating capability index, and relative regulating index were defined to characterize the temperature regulating properties. The measurement principle, the evaluation criteria and grading method, the experimental setup and the test results discussion, and the gage capability analysis of the apparatus are presented. The new apparatus provides a method for the objective measurement and evaluation of the temperature regulating properties of thermal functional porous polymeric materials.

  4. Design and implementation of a shearing apparatus for the experimental study of shear displacement in rocks

    Science.gov (United States)

    Moore, Johnathan; Crandall, Dustin; Gill, Magdalena; Brown, Sarah; Tennant, Bryan

    2018-04-01

    Fluid flow in the subsurface is not well understood in the context of "impermeable" geologic media. This is especially true of formations that have undergone significant stress fluctuations due to injection or withdrawal of fluids that alters the localized pressure regime. When the pressure regime is altered, these formations, which are often already fractured, move via shear to reduce the imbalance in the stress state. While this process is known to happen, the evolution of these fractures and their effects on fluid transport are still relatively unknown. Numerous simulation and several experimental studies have been performed that characterize the relationship between shearing and permeability in fractures; while many of these studies utilize measurements of fluid flow or the starting and ending geometries of the fracture to characterize shear, they do not characterize the intermediate stages during shear. We present an experimental apparatus based on slight modifications to a commonly available Hassler core holder that allows for shearing of rocks, while measuring the hydraulic and mechanical changes to geomaterials during intermediate steps. The core holder modification employs the use of semi-circular end caps and structural supports for the confining membrane that allow for free movement of the sheared material while preventing membrane collapse. By integrating this modified core holder with a computed tomography scanner, we show a new methodology for understanding the interdependent behavior between fracture structure and flow properties during intermediate steps in shearing. We include a case study of this device function which is shown here through shearing of a fractured shale core and simultaneous observation of the mechanical changes and evolution of the hydraulic properties during shearing.

  5. Nonlocal Regularized Algebraic Reconstruction Techniques for MRI: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Xin Li

    2013-01-01

    Full Text Available We attempt to revitalize researchers' interest in algebraic reconstruction techniques (ART by expanding their capabilities and demonstrating their potential in speeding up the process of MRI acquisition. Using a continuous-to-discrete model, we experimentally study the application of ART into MRI reconstruction which unifies previous nonuniform-fast-Fourier-transform- (NUFFT- based and gridding-based approaches. Under the framework of ART, we advocate the use of nonlocal regularization techniques which are leveraged from our previous research on modeling photographic images. It is experimentally shown that nonlocal regularization ART (NR-ART can often outperform their local counterparts in terms of both subjective and objective qualities of reconstructed images. On one real-world k-space data set, we find that nonlocal regularization can achieve satisfactory reconstruction from as few as one-third of samples. We also address an issue related to image reconstruction from real-world k-space data but overlooked in the open literature: the consistency of reconstructed images across different resolutions. A resolution-consistent extension of NR-ART is developed and shown to effectively suppress the artifacts arising from frequency extrapolation. Both source codes and experimental results of this work are made fully reproducible.

  6. A novel experimental technique of nuclear lifetime measurements

    International Nuclear Information System (INIS)

    Yuminov, O.A.; D'Arrigo, A.; Giardina, G.; Taccone, A.; Vannini, G.; Moroni, A.; Ricci, R.A.; Vannucci, L.

    1995-01-01

    In the present paper a new experimental method to measure nuclear reaction time in the 10 -15 -10 -10 s region is presented. Measurements of the lifetimes of low-lying and long-lived states of 19 F and 20 Ne decaying via α-channel were carried out with the aim of checking the feasibility of the method. The results obtained in this way are compared with the lifetimes known from different techniques. ((orig.))

  7. Self-propelled pulse X-ray apparatus Sirena-1

    International Nuclear Information System (INIS)

    Danil'chenko, N.T.; Ershov, L.S.; Il'chenko, A.V.; Krasil'nikov, S.B.; Kristalinskij, A.L.; Lozovoj, L.N.; Markov, S.N.; Morgovskij, L.Ya.

    1984-01-01

    The structure and specifications of a self-propelled pulse X-ray apparatus ''Sirena-1'' for testing oilt and gas pipelines welded joints are described. The apparatus is designed on the base of pulse X-ray apparatus MIRA. Apparatus control is realized by means of the 137 Cs source or manual control desk. The apparatus ensures perfect control sensitivity

  8. Encephalographic apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    An X-ray apparatus is described for determining the size and location of brain tumours by tomography during pneumoencephalography. The apparatus comprises an image recording device arranged opposite an X-ray source and a frame mounted on a tiltable patient table and rotatable with respect to the table. A patient support is arranged in the frame and is rotatable with respect to the frame. Air injected into the patients' spinal column travels up into the brain and displaces some of the cerebral fluid. Tomographic X-ray exposures are made of the air bubble which moves around in the brain cavities as the patient is rotated. (U.K.)

  9. Radiography apparatus

    International Nuclear Information System (INIS)

    Sashin, D.; Sternglass, E.J.

    1982-01-01

    The apparatus of the present invention provides radiography apparatus wherein the use of a flat, generally rectangular beam or a fan-shaped beam of radiation in combination with a collimator, scintillator and device for optically coupling a self-scanning array of photodiodes to the scintillator means will permit production of images or image data with high contrast sensitivity and detail. It is contemplated that the self-scanning array of photodiodes may contain from about 60 to 2048, and preferably about 256 to 2048, individual photodiode elements per inch of object width, thereby permitting maximum data collection to produce a complete image or complete collection of image data

  10. Positioning calibration apparatus for transducers employed in nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Elsner, H.J.

    1979-01-01

    Calibration apparatus for verifying the position and orientation of transducers used in nuclear reactor vessel inspection apparatus is disclosed. A tank, filled with water, the operating inspection medium, is fitted with a movable mounting assembly adapted to securely accommodate a transducer and the mounting assembly in which it is normally secured during an inspection procedure. The tank is also provided with a slidably mounted target positioned therein at a predetermined distance from the target which is selected to avoid the distortion effects in the near field of the transducer response. The calibration apparatus can be used to check the normal transducer mounting for either perpendicularity or angular orientation by moving the tank's mounting assembly via a lead screw with which it is threadingly engaged. 6 claims

  11. An experimental technique to measure the capillary waves in electrified microjets

    Directory of Open Access Journals (Sweden)

    Rebollo-Muñoz Noelia

    2012-04-01

    Full Text Available Backlight optical imaging is an experimental technique with an enormous potential in microfluidics to study very varied fluid configurations and phenomena. In this paper, we show the capability of this technique to precisely characterize the capillary waves growing in electrified microjets. For this purpose, images of electrified liquid jets formed by electrospray were acquired and processed using a sub-pixel resolution technique. Our results reflect the validity and usefulness of optical imaging for this type of application.

  12. Method And Apparatus For Evaluatin Of High Temperature Superconductors

    Science.gov (United States)

    Fishman, Ilya M.; Kino, Gordon S.

    1996-11-12

    A technique for evaluation of high-T.sub.c superconducting films and single crystals is based on measurement of temperature dependence of differential optical reflectivity of high-T.sub.c materials. In the claimed method, specific parameters of the superconducting transition such as the critical temperature, anisotropy of the differential optical reflectivity response, and the part of the optical losses related to sample quality are measured. The apparatus for performing this technique includes pump and probe sources, cooling means for sweeping sample temperature across the critical temperature and polarization controller for controlling a state of polarization of a probe light beam.

  13. Experimental apparatus to determine lead attenuation coefficients for photons of 0.511 MeV; Aparato experimental para determinar os coeficientes de atenuação no chumbo para fótons de 0,511 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, Luis C.B.; Cardoso, Domingos O.; Gavazza, Sérgio; Morales, Rudnei K., E-mail: claudiovargasbrito@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Oliveira, Luciano S. R. [Instituto de Defesa Química Biológica Radiológica Nuclear (IDQBRN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Radioactive gamma-emitting sources with higher energies than 1.022 MeV, may interact with matter by pair production process, generating two photons of 0.511 MeV in the positron annihilation, that may contribute to increase doses in both IOE´s or public. National regulatory agencies require a radiation protection plan and a shielding project to consider the influence of these photons in the licensing procedure. This work will present all steps for the development of the experimental apparatus for determination of the attenuation coefficients for photons with energy of 0.511 MeV in lead. (author)

  14. Tomographic apparatus for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    After briefly reviewing the history of computerised tomography, the deficiencies inherent in the various methods that have been adopted are discussed, e.g. slow data collection time, blurring of images and poor spatial resolution. Tomographic apparatus and processing methods are then described which can overcome these problems. The apparatus consists of a fan-shaped source of X-rays and a detector array which both rotate around the patient being examined. The data reduction process is derived in great detail; it is claimed that digital processing using convolution techniques is much faster than conventional methods. (U.K.)

  15. Development of an apparatus to measure thermophysical properties of wind tunnel heat transfer models

    Science.gov (United States)

    Romanowski, R. F.; Steinberg, I. H.

    1974-01-01

    The apparatus and technique for measuring the thermophysical properties of models used with the phase-change paint method for obtaining wind tunnel heat transfer data are described. The method allows rapid measurement of the combined properties in a transient manner similar to an actual wind tunnel test. An effective value of the thermophysical properties can be determined which accounts for changes in thermal properties with temperature or with depth into the model surface. The apparatus was successfully tested at various heating rates between 19,000 and 124,000 watts per square meter.

  16. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  17. Nuclear core baffling apparatus

    International Nuclear Information System (INIS)

    Cooper, F.W. Jr.; Silverblatt, B.L.; Knight, C.B.; Berringer, R.T.

    1979-01-01

    An apparatus for baffling the flow of reactor coolant fluid into and about the core of a nuclear reactor is described. The apparatus includes a plurality of longitudinally aligned baffle plates with mating surfaces that allow longitudinal growth with temperature increases while alleviating both leakage through the aligned plates and stresses on the components supporting the plates

  18. Experimental verifications of a structural damage identification technique using reduced order finite-element model

    Science.gov (United States)

    Li, Rui; Zhou, Li; Yang, Jann N.

    2010-04-01

    An objective of the structural health monitoring system is to identify the state of the structure and to detect the damage when it occurs. Analysis techniques for the damage identification of structures, based on vibration data measured from sensors, have received considerable attention. Recently, a new damage tracking technique, referred to as the adaptive quadratic sum-square error (AQSSE) technique, has been proposed, and simulation studies demonstrated that the AQSSE technique is quite effective in identifying structural damages. In this paper, the adaptive quadratic sumsquare error (AQSSE) along with the reduced-order finite-element method is proposed to identify the damages of complex structures. Experimental tests were conducted to verify the capability of the proposed damage detection approach. A series of experimental tests were performed using a scaled cantilever beam subject to the white noise and sinusoidal excitations. The capability of the proposed reduced-order finite-element based adaptive quadratic sum-square error (AQSSE) method in detecting the structural damage is demonstrated by the experimental results.

  19. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus

    Directory of Open Access Journals (Sweden)

    Yugang Huang

    2013-06-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 To improve the repeatability of the injection molding test result, the affecting factors were investigated by means of experiments. Besides the traditional processing parameter, the factors of test conditions were also considered. In order to focus on the molding process rather than the molded part, the curve measurement of the melt pressure at the entrance to the nozzle was used as the output characteristic. Experiments for polypropylene (PP showed that the injected volume was the key processing parameter. Within the test conditions, the injection number is the most important factor. According to the analysis the operating procedure was improved effectively. Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Doi: 10.12777/ijse.5.1.6-11 [How to cite this article: Huang, Y., Li, D., Liu, Y. (2013. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus. International Journal of Science and Engineering, 5(1,6-11. Doi: 10.12777/ijse.5.1.6-11]

  20. High-temperature apparatus for chaotic mixing of natural silicate melts

    Energy Technology Data Exchange (ETDEWEB)

    Morgavi, D.; Petrelli, M.; Vetere, F. P.; González-García, D.; Perugini, D., E-mail: diego.perugini@unipg.it [Department of Physics and Geology, Petro-Volcanology Research Group (PVRG), University of Perugia, Piazza Università, Perugia 06100 (Italy)

    2015-10-15

    A unique high-temperature apparatus was developed to trigger chaotic mixing at high-temperature (up to 1800 °C). This new apparatus, which we term Chaotic Magma Mixing Apparatus (COMMA), is designed to carry out experiments with high-temperature and high-viscosity (up to 10{sup 6} Pa s) natural silicate melts. This instrument allows us to follow in time and space the evolution of the mixing process and the associated modulation of chemical composition. This is essential to understand the dynamics of magma mixing and related chemical exchanges. The COMMA device is tested by mixing natural melts from Aeolian Islands (Italy). The experiment was performed at 1180 °C using shoshonite and rhyolite melts, resulting in a viscosity ratio of more than three orders of magnitude. This viscosity ratio is close to the maximum possible ratio of viscosity between high-temperature natural silicate melts. Results indicate that the generated mixing structures are topologically identical to those observed in natural volcanic rocks highlighting the enormous potential of the COMMA to replicate, as a first approximation, the same mixing patterns observed in the natural environment. COMMA can be used to investigate in detail the space and time development of magma mixing providing information about this fundamental petrological and volcanological process that would be impossible to investigate by direct observations. Among the potentials of this new experimental device is the construction of empirical relationships relating the mixing time, obtained through experimental time series, and chemical exchanges between the melts to constrain the mixing-to-eruption time of volcanic systems, a fundamental topic in volcanic hazard assessment.

  1. High-temperature apparatus for chaotic mixing of natural silicate melts

    International Nuclear Information System (INIS)

    Morgavi, D.; Petrelli, M.; Vetere, F. P.; González-García, D.; Perugini, D.

    2015-01-01

    A unique high-temperature apparatus was developed to trigger chaotic mixing at high-temperature (up to 1800 °C). This new apparatus, which we term Chaotic Magma Mixing Apparatus (COMMA), is designed to carry out experiments with high-temperature and high-viscosity (up to 10 6 Pa s) natural silicate melts. This instrument allows us to follow in time and space the evolution of the mixing process and the associated modulation of chemical composition. This is essential to understand the dynamics of magma mixing and related chemical exchanges. The COMMA device is tested by mixing natural melts from Aeolian Islands (Italy). The experiment was performed at 1180 °C using shoshonite and rhyolite melts, resulting in a viscosity ratio of more than three orders of magnitude. This viscosity ratio is close to the maximum possible ratio of viscosity between high-temperature natural silicate melts. Results indicate that the generated mixing structures are topologically identical to those observed in natural volcanic rocks highlighting the enormous potential of the COMMA to replicate, as a first approximation, the same mixing patterns observed in the natural environment. COMMA can be used to investigate in detail the space and time development of magma mixing providing information about this fundamental petrological and volcanological process that would be impossible to investigate by direct observations. Among the potentials of this new experimental device is the construction of empirical relationships relating the mixing time, obtained through experimental time series, and chemical exchanges between the melts to constrain the mixing-to-eruption time of volcanic systems, a fundamental topic in volcanic hazard assessment

  2. Shielding in experimental areas

    International Nuclear Information System (INIS)

    Stevens, A.; Tarnopolsky, G.; Thorndike, A.; White, S.

    1979-01-01

    The amount of shielding necessary to protect experimental detectors from various sources of background radiation is discussed. As illustrated an experiment has line of sight to sources extending approx. 90 m upstream from the intersection point. Packing a significant fraction of this space with shielding blocks would in general be unacceptable because primary access to the ring tunnel is from the experimental halls. (1) From basic machine design considerations and the inherent necessity to protect superconducting magnets it is expected that experimental areas in general will be cleaner than at any existing accelerator. (2) Even so, it will likely be necessary to have some shielding blocks available to protect experimental apparatus, and it may well be necessary to have a large amount of shielding available in the WAH. (3) Scraping will likely have some influence on all halls, and retractable apparatus may sometimes be necessary. (4) If access to any tunnel is needed to replace a magnet, one has 96 h (4 days) available to move shielding away to permit access without additional downtime. This (the amount of shielding one can shuffle about in 96 h) is a reasonable upper limit to shielding necessary in a hall

  3. Experimental techniques for the consolidation of the neutron spectrum

    International Nuclear Information System (INIS)

    Chiaraviglio, N.; Bazzana, S.

    2013-01-01

    Unfolding techniques are widely known but their use is not widespread due to their complexity. Such procedure consists in the adjustment of calculated quantities to experimental results by the modification of the neutron spectrum, getting correction factors for the calculated quantities. In this work we describe the general procedure that must be executed for a neutron spectrum unfolding. (author) [es

  4. Radioactive waste material melter apparatus

    Science.gov (United States)

    Newman, D.F.; Ross, W.A.

    1990-04-24

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs.

  5. Radioactive waste material melter apparatus

    International Nuclear Information System (INIS)

    Newman, D.F.; Ross, W.A.

    1990-01-01

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs

  6. Experimental evaluation of a quasi-modal parameter based rotor foundation identification technique

    Science.gov (United States)

    Yu, Minli; Liu, Jike; Feng, Ningsheng; Hahn, Eric J.

    2017-12-01

    Correct modelling of the foundation of rotating machinery is an invaluable asset in model-based rotor dynamic study. One attractive approach for such purpose is to identify the relevant modal parameters of an equivalent foundation using the motion measurements of rotor and foundation at the bearing supports. Previous research showed that, a complex quasi-modal parameter based system identification technique could be feasible for this purpose; however, the technique was only validated by identifying simple structures under harmonic excitation. In this paper, such identification technique is further extended and evaluated by identifying the foundation of a numerical rotor-bearing-foundation system and an experimental rotor rig respectively. In the identification of rotor foundation with multiple bearing supports, all application points of excitation forces transmitted through bearings need to be included; however the assumed vibration modes far outside the rotor operating speed cannot or not necessary to be identified. The extended identification technique allows one to identify correctly an equivalent foundation with fewer modes than the assumed number of degrees of freedom, essentially by generalising the technique to be able to handle rectangular complex modal matrices. The extended technique is robust in numerical and experimental validation and is therefore likely to be applicable in the field.

  7. An apparatus to study the energy and angular distributions of electron-bremsstrahlung photons from gaseous targets

    International Nuclear Information System (INIS)

    Yadav, Namita; Bhatt, Pragya; Singh, Raj; Singh, B.K.; Quarles, C.A.; Shanker, R.

    2014-01-01

    An apparatus is developed to measure the energy- and angular distributions of bremsstrahlung generated from collisions of energetic electrons with isolated atoms and molecules. A considerable reduction of thick target bremsstrahlung (TTB) background produced by scattered electrons from the chamber wall is achieved. Details of the experimental setup with regard to design of its components, experimental technique, data acquisition and analysis etc. are given and discussed. The reliability and performance of the setup are demonstrated by obtaining some test results on angular- and energy distributions of bremsstrahlung produced in collisions of 4.0 keV electrons with free argon atoms. These results are compared with the theoretical predictions of the ordinary- and the polarization bremsstrahlung emissions. In this comparison, the experimental data for energy distributions of BS photons are found to be in reasonable agreement while they are found to have noticeable differences in shape of angular distributions. - Highlights: • Experimental setup is developed to study DDCS of electron-bremsstrahlung from gaseous targets. • TTB from scattering chamber's wall is reduced appreciably by using a teflon cylinder. • Shape of DDCS of bremsstrahlung compared with the theories shows a satisfactory match. • Angular distributions of bremsstrahlung show anisotropy but still affected by TTB background photons

  8. The design of high-temperature thermal conductivity measurements apparatus for thin sample size

    Directory of Open Access Journals (Sweden)

    Hadi Syamsul

    2017-01-01

    Full Text Available This study presents the designing, constructing and validating processes of thermal conductivity apparatus using steady-state heat-transfer techniques with the capability of testing a material at high temperatures. This design is an improvement from ASTM D5470 standard where meter-bars with the equal cross-sectional area were used to extrapolate surface temperature and measure heat transfer across a sample. There were two meter-bars in apparatus where each was placed three thermocouples. This Apparatus using a heater with a power of 1,000 watts, and cooling water to stable condition. The pressure applied was 3.4 MPa at the cross-sectional area of 113.09 mm2 meter-bar and thermal grease to minimized interfacial thermal contact resistance. To determine the performance, the validating process proceeded by comparing the results with thermal conductivity obtained by THB 500 made by LINSEIS. The tests showed the thermal conductivity of the stainless steel and bronze are 15.28 Wm-1K-1 and 38.01 Wm-1K-1 with a difference of test apparatus THB 500 are −2.55% and 2.49%. Furthermore, this apparatus has the capability to measure the thermal conductivity of the material to a temperature of 400°C where the results for the thermal conductivity of stainless steel is 19.21 Wm-1K-1 and the difference was 7.93%.

  9. Fractionation and rectification apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Sauerwald, A

    1932-05-25

    Fractionation and rectifying apparatus with a distillation vessel and a stirring tube, drainage tubes leading from its coils to a central collecting tube, the drainage tubes being somewhat parallel and attached to the outer half of the stirring tube and partly on the inner half of the central collecting tube, whereby distillation and rectification can be effected in a single apparatus.

  10. Experimental determination of liquidus of Fe-Zr by spot technique

    International Nuclear Information System (INIS)

    Ramakrishna, P.; Samanta, B.; Balakrishnan, S.

    2016-01-01

    Metallic fuel alloy for fast reactor mainly consist of U-Pu-Zr housed in T91 clad. Study of thermophysical properties of fuel element and cladding material is vital for the fuel designer to optimize the design feature and predict the fuel behavior under reactor operating conditions.To understand the fuel-clad interaction the phase diagram study of Fe-Zr system is very important since future reactors use U-Pu-Zr alloy as fuel and stainless steel as clad. The eutectic temperature in Fe-Zr alloy system has been established experimentally by various methods. Information on the liquidus temperatures of Fe-Zr is scanty in the literature excepting a very few experimental measurements. Hence measurement of liquidus temperatures is very essential to establish the phase diagram. Present work concentrates more on the generation of liquidus data of Fe-Zr binary alloy system by Spot-technique. This is one among the advanced techniques for measuring the solid-liquid phase transition temperatures. (author)

  11. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be equipped with a substantial, durable container bearing markings which show the applicant's name, the type...

  12. Experimental methods of reactor physics; Methodes experimentales de physique des reacteurs a neutrons thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D; Lafore, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    This paper is a synthesis of various experimental methods in use with the reactors of the Commissariat a l'Energie Atomique. The main techniques used are mentioned and the difficulties encountered and the accuracy obtained are particularly dwelt upon. The application of these various methods to reactors in order to obtain specific results is also indicated. This paper consists of five parts. I - General methods. Macroscopic and microscopic flux distribution (anisotropy effect), power distribution, etc... II - Kinetic measurements a) pulsed neutron technique: apparatus and accuracy; application to {lambda}t and to anti reactivity measurements; application to graphite, light water and beryllium oxide. b) oscillation techniques: equipment and accuracy; application to the measurements of effective cross sections and resonance integrals. c) fluctuations: apparatus and technique of measurement. III - Poison methods. Description of methods for introducing and extracting the poison, difficulties encountered with light and heavy water, measurement of temperature coefficients and anti-reactivity. IV - Spectra measurements. Choice and development of foils, problems of measurement, application to spectral measurements for thermalization studies, application to dosimetry. V - Experimental shielding measurements. The technique and apparatus recently developed in this field are presented. (authors) [French] Cette communication fait une synthese des differentes methodes experimentales mises en oeuvre sur les reacteurs du CEA. Elle presente les principales techniques utilisees et insiste plus particulierement sur les difficultes rencontrees et la precision obtenue; elle indique egalement l'application de ces differentes methodes sur les reacteurs, en vue de l'obtention des resultats determines. Elle comporte cinq parties: I - METHODES GENERALES: Distribution de flux macroscopique et microscopique (effet d'anisotropie), distribution de puissance, etc... II - MESURES CINETIQUES: a

  13. Phase behavior of multicomponent membranes: Experimental and computational techniques

    DEFF Research Database (Denmark)

    Bagatolli, Luis; Kumar, P.B. Sunil

    2009-01-01

    Recent developments in biology seems to indicate that the Fluid Mosaic model of membrane proposed by Singer and Nicolson, with lipid bilayer functioning only as medium to support protein machinery, may be too simple to be realistic. Many protein functions are now known to depend on the compositio....... This review includes basic foundations on membrane model systems and experimental approaches applied in the membrane research area, stressing on recent advances in the experimental and computational techniques....... membranes. Current increase in interest in the domain formation in multicomponent membranes also stems from the experiments demonstrating liquid ordered-liquid disordered coexistence in mixtures of lipids and cholesterol and the success of several computational models in predicting their behavior...

  14. A simple apparatus for measuring the blood urea, manufactured by Dr. Luigj Benusi in 1943 in Albania

    OpenAIRE

    Tartari, Flamur; Buzo, Stiliano; Vyshka, Gentian

    2009-01-01

    The apparatus invented by Dr. Luigj Benusi in 1943, in Tirana, was a practical application of the Kowarsky technique and Ambard laws, helping in determining blood urea levels and very important to a variety of diseases, mainly kidney disorders. The apparatus was invented and prepared from very simple laboratory materials, such as glasses, test tubes, corks and volumetric cylinders. Technologically, it was based upon the determination of blood urea through hypobromite, and, among the advantage...

  15. [The comparative assessment of the wound-healing effects of the treatment with the use of Bioptron, Minitag, Orion+ apparatuses and hollow cathode lamps (experimental study)].

    Science.gov (United States)

    Sharipova, M M; Voronova, S N; Rukin, E M; Vasilenko, A M

    2011-01-01

    The objective of the present experimental study was the comparative assessment of the wound-healing effects of radiation emitted from Bioptron, Minitag, Orion+ apparatuses and hollow cathode lamps (HCL). The emitters of any type were shown to be equally efficacious in that they accelerated wound epithelization by 30% on the average compared with control. Based on the difference between spectral and power characteristics of different sources of radiation and dynamics of their wound-healing efficacy (including that of two types of HCL), the authors arrived at the conclusion that the further development of the proposed approach to wound healing is a promising line of research in the field of spectral phototherapy.

  16. Experimental verification of radial magnetic levitation force on the cylindrical magnets in ferrofluid dampers

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wenming, E-mail: wenming_y@126.com [School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Wang, Pengkai [School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Hao, Ruican [School of Mechanical Engineering, Beijing Polytechnic, Beijing 100176 (China); Ma, Buchuan [Beijing Institute of Aerospace Control Devices, Beijing 100854 (China)

    2017-03-15

    Analytical and numerical calculation methods of the radial magnetic levitation force on the cylindrical magnets in cylindrical vessels filled with ferrofluid was reviewed. An experimental apparatus to measure this force was designed and tailored, which could measure the forces in a range of 0–2.0 N with an accuracy of 0.001 N. After calibrated, this apparatus was used to study the radial magnetic levitation force experimentally. The results showed that the numerical method overestimates this force, while the analytical ones underestimate it. The maximum deviation between the numerical results and the experimental ones was 18.5%, while that between the experimental results with the analytical ones attained 68.5%. The latter deviation narrowed with the lengthening of the magnets. With the aids of the experimental verification of the radial magnetic levitation force, the effect of eccentric distance of magnets on the viscous energy dissipation in ferrofluid dampers could be assessed. It was shown that ignorance of the eccentricity of magnets during the estimation could overestimate the viscous dissipation in ferrofluid dampers. - Highlights: • Experimental method measuring magnetic levitation force of ferrofluid was studied. • A simple but rather witty apparatus was designed and tailored. • The apparatus can measure forces in a range of 0–2.0 N with an accuracy of 0.001 N. • Existing methods calculating magnetic levitation force were verified experimentally.

  17. Experimental verification of radial magnetic levitation force on the cylindrical magnets in ferrofluid dampers

    International Nuclear Information System (INIS)

    Yang, Wenming; Wang, Pengkai; Hao, Ruican; Ma, Buchuan

    2017-01-01

    Analytical and numerical calculation methods of the radial magnetic levitation force on the cylindrical magnets in cylindrical vessels filled with ferrofluid was reviewed. An experimental apparatus to measure this force was designed and tailored, which could measure the forces in a range of 0–2.0 N with an accuracy of 0.001 N. After calibrated, this apparatus was used to study the radial magnetic levitation force experimentally. The results showed that the numerical method overestimates this force, while the analytical ones underestimate it. The maximum deviation between the numerical results and the experimental ones was 18.5%, while that between the experimental results with the analytical ones attained 68.5%. The latter deviation narrowed with the lengthening of the magnets. With the aids of the experimental verification of the radial magnetic levitation force, the effect of eccentric distance of magnets on the viscous energy dissipation in ferrofluid dampers could be assessed. It was shown that ignorance of the eccentricity of magnets during the estimation could overestimate the viscous dissipation in ferrofluid dampers. - Highlights: • Experimental method measuring magnetic levitation force of ferrofluid was studied. • A simple but rather witty apparatus was designed and tailored. • The apparatus can measure forces in a range of 0–2.0 N with an accuracy of 0.001 N. • Existing methods calculating magnetic levitation force were verified experimentally.

  18. Radioactive waste processing apparatus

    Science.gov (United States)

    Nelson, R.E.; Ziegler, A.A.; Serino, D.F.; Basnar, P.J.

    1985-08-30

    Apparatus for use in processing radioactive waste materials for shipment and storage in solid form in a container is disclosed. The container includes a top, and an opening in the top which is smaller than the outer circumference of the container. The apparatus includes an enclosure into which the container is placed, solution feed apparatus for adding a solution containing radioactive waste materials into the container through the container opening, and at least one rotatable blade for blending the solution with a fixing agent such as cement or the like as the solution is added into the container. The blade is constructed so that it can pass through the opening in the top of the container. The rotational axis of the blade is displaced from the center of the blade so that after the blade passes through the opening, the blade and container can be adjusted so that one edge of the blade is adjacent the cylindrical wall of the container, to insure thorough mixing. When the blade is inside the container, a substantially sealed chamber is formed to contain vapors created by the chemical action of the waste solution and fixant, and vapors emanating through the opening in the container. The chamber may be formed by placing a removable extension over the top of the container. The extension communicates with the apparatus so that such vapors are contained within the container, extension and solution feed apparatus. A portion of the chamber includes coolant which condenses the vapors. The resulting condensate is returned to the container by the force of gravity.

  19. Switched-mode power supply apparatus and method

    NARCIS (Netherlands)

    2013-01-01

    The present invention relates to a switched-mode power supply apparatus and a corresponding method. For an effective compensation of non-linearities caused by dead- time and voltage drops in the switching power amplifier of the apparatus, an apparatus is proposed comprising a switching power

  20. Switched-mode power supply apparatus and method

    NARCIS (Netherlands)

    2013-01-01

    The present invention relates to a switched-mode power supply apparatus and a corresponding method. For an effective compensation of non-linearities caused by dead-time and voltage drops in the switching power amplifier of the apparatus, an apparatus is proposed comprising a switching power

  1. Experimental techniques for the study of radiation damage in metals and alloys

    International Nuclear Information System (INIS)

    Novion, C.H. de.

    1983-06-01

    In this review, one presents the main experimental techniques used to study point defects and defect clusters introduced by irradiation in metals and alloys; emphasis will be put on some recent techniques. In particular, the studies allowing to analyse the very small agglomerates of point defects (Huang and small angle scattering, positron annihilation, electron microscopy) will be compared [fr

  2. EXTRACTION APPARATUS

    Science.gov (United States)

    Ballard, A.E.; Brigham, H.R.

    1958-10-28

    An apparatus whereby relatlvely volatile solvents may be contacted with volatile or non-volatile material without certaln attendant hazards is described. A suitable apparatus for handling relatively volatlle liqulds may be constructed comprising a tank, and a closure covering the tank and adapted to be securely attached to an external suppont. The closure is provided with a rigidly mounted motor-driven agitator. This agitator is connected from the driving motor lnto the lnterlor of the tank through a gland adapted to be cooled witb inert gas thereby eliminating possible hazard due to frictional heat. The closure is arranged so that the tank may be removed from it without materially dlsturbing the closure which, as described, carrles the motor driven agitator and other parts.

  3. Apparatus for ultrasonic nebulization

    International Nuclear Information System (INIS)

    Olson, K.W.; Haas, W.J. Jr.; Fassel, V.A.

    1978-01-01

    An improved apparatus is described for ultrasonic nebulization of liquid samples or suspensions in which the piezoelectric transducer is protected from chemical attack and erosion. The transducer is protected by being bonded to the inner surface of a glass plate which forms one end wall of a first hollow body provided with apparatus for circulating a fluid for cooling and stabilizing the transducer. The glass plate, which is one-half wavelength in thickness to provide an acoustically coupled outer nebulizing surface, seals an opening in a second hollow body which encloses an aerosol mixing chamber. The second body includes apparatus for delivering the sample solution to the nebulizing surface, a gas inlet for providing a flow of carrier gas for transporting the aerosol of the nebulized sample and an aerosol outlet

  4. Validation for a new apparatus measuring water vapour enhancement factors up to 6 MPa

    International Nuclear Information System (INIS)

    Sairanen, H; Heinonen, M

    2014-01-01

    High accuracy dew-point measurements require a water vapour enhancement factor to correct the effects of pressure drop in a sampling line. The enhancement factor is also needed when a humidity quantity value is converted to another. In this paper a new apparatus for traceable measurements of the enhancement factor is presented along with the results of validation measurements with air and methane. The apparatus is designed for dew-point temperatures from −50 to +15 °C and the pressure range from atmospheric pressure up to 6 MPa. The performance of the apparatus was investigated by comparing measurement results to the literature data for air and the data calculated from published thermodynamic measurement results for methane. It is shown that the experimental results agree with the reference data within the estimated uncertainties. (paper)

  5. A new apparatus for the determination of adsorption isotherms and adsorption enthalpies on microporous and meso-porous media

    International Nuclear Information System (INIS)

    Mouahid, A.

    2010-01-01

    A specific thermostated experimental device comprising a differential heat flow calorimeter coupled with a home built manometric system has been built for the simultaneous determination of adsorption isotherms and adsorption enthalpies. The differential heat flow calorimeter is a Tian Calvet Setaram C80 model which measures the heat flux of a gas and can be operated isothermally, the manometric system is a stainless steel homemade apparatus. This coupled apparatus allows measurements for pressure up to 2.5 MPa and temperature up to 423.15 K. On the one hand, the apparatus and the experimental procedures are described. On the second hand the reliability and reproducibility were established by measuring adsorption isotherms on a benchmark (Filtrasorb F400) at 318.15 K. The gravimetric method has been used at higher pressure at various temperatures. These devices allowed us to study the adsorption of supercritical fluid (nitrogen N 2 , methane CH 4 , carbon dioxide CO 2 ) in activated carbons and microporous or meso-porous silica. The adsorption of methane on a rock of type (TGR) was also studied. These experimental results are used for the study of the interactions fluid / solid that must be taken into account in molecular simulations or DFT theory. (author)

  6. Nuclear magnetic resonance method and apparatus

    International Nuclear Information System (INIS)

    Young, I.R.

    1983-01-01

    In a method of investigating the distribution of a quantity in a chosen region of a body (E) by nuclear magnetic resonance techniques movement of the body during the investigation is monitored by probes (A, B C) (C extends orthogonally to A and B) attached to the body and responsive to magnetic fields applied to the body during the investigation. An apparatus for carrying out the method is also described. If movement is detected, due compensation may be made during processing of the collected data, or the latter may be re-ascertained after appropriate adjustment e.g. a change in the RF excitation frequency. (author)

  7. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  8. Infrared microscope inspection apparatus

    Science.gov (United States)

    Forman, Steven E.; Caunt, James W.

    1985-02-26

    Apparatus and system for inspecting infrared transparents, such as an array of photovoltaic modules containing silicon solar cells, includes an infrared microscope, at least three sources of infrared light placed around and having their axes intersect the center of the object field and means for sending the reflected light through the microscope. The apparatus is adapted to be mounted on an X-Y translator positioned adjacent the object surface.

  9. Techniques for Improving the Accuracy of 802.11 WLAN-Based Networking Experimentation

    Directory of Open Access Journals (Sweden)

    Portoles-Comeras Marc

    2010-01-01

    Full Text Available Wireless networking experimentation research has become highly popular due to both the frequent mismatch between theory and practice and the widespread availability of low-cost WLAN cards. However, current WLAN solutions present a series of performance issues, sometimes difficult to predict in advance, that may compromise the validity of the results gathered. This paper surveys recent literature dealing with such issues and draws attention on the negative results of starting experimental research without properly understanding the tools that are going to be used. Furthermore, the paper details how a conscious assessment strategy can prevent placing wrong assumptions on the hardware. Indeed, there are numerous techniques that have been described throughout the literature that can be used to obtain a deeper understanding of the solutions that have been adopted. The paper surveys these techniques and classifies them in order to provide a handful reference for building experimental setups from which accurate measurements may be obtained.

  10. Freezing Point Depressions of Aqueous MEA, MDEA, and MEA−MDEA Measured with a New Apparatus

    DEFF Research Database (Denmark)

    Fosbøl, Philip Loldrup; Pedersen, Mikkel Gielsager; Thomsen, Kaj

    2011-01-01

    Freezing points for aqueous monoethanolamine (MEA), methyl diethanolamine (MDEA), and MEA−MDEA solutions were measured in the concentration range from 0 to 0.4 mass fractions of the alkanolamines. For the aqueous MEA−MDEA system, freezing points for 1:4, 1:2, 1:1, 2:1, and 4:1 molar ratios of MEA....../MDEA were determined. The experimental values indicate that the MDEA−water interaction is stronger than the MEA−water interaction. Measurements were carried out by a new modified Beckmann apparatus, which has not previously been described. The apparatus and method proved to have good repeatability...

  11. Apparatus and methods for investigations into acoustic properties of electronic melts

    International Nuclear Information System (INIS)

    Glazov, V.M.; Timoshenko, V.I.; Kim, S.G.

    1985-01-01

    Apparatus and highly sensitive methods of systematic investigations into acoustic properties of electronic melts are described. A variant of a measuring cell to investigate agressive melts is presented. A new technique for the reception of an acoustic contact with high transmission capacity of ultrasonic wave based on utilization of clarified layers of liquid boron anhydride is described. Results of calibration tests on lead and aluminium melts point to a good agreement with literature data. High sensitivity of the above technique allows one to reveal thin structural effects in melts

  12. Experimental and theoretical contributions to X-ray phase-contrast techniques for medical imaging

    International Nuclear Information System (INIS)

    Diemoz, P.C.

    2011-01-01

    Several X-ray phase-contrast techniques have recently been developed. Unlike conventional X-ray methods, which measure the absorption properties of the tissues, these techniques derive contrast also from the modulation of the phase produced by the sample. Since the phase shift can be significant even for small details characterized by weak or absent absorption, the achievable image contrast can be greatly increased, notably for the soft biological tissues. These methods are therefore very promising for applications in the medical domain. The aim of this work is to contribute to a deeper understanding of these techniques, in particular propagation-based imaging (PBI), analyzer-based imaging (ABI) and grating interferometry (GIFM), and to study their potential and the best practical implementation for medical imaging applications. An important part of this work is dedicated to the use of mathematical algorithms for the extraction, from the acquired images, of quantitative sample information (the absorption, refraction and scattering sample properties). In particular, five among the most known algorithms based on the geometrical optics approximation have been theoretically analysed and experimentally compared, in planar and tomographic modalities, by using geometrical phantoms and human bone-cartilage and breast samples. A semi-quantitative method for the acquisition and reconstruction of tomographic images in the ABI and GIFM techniques has also been proposed. The validity conditions are analyzed in detail and the method, enabling a considerable simplification of the imaging procedure, has been experimentally checked on phantoms and human samples. Finally, a theoretical and experimental comparison of the PBI, ABI and GIFM techniques is presented. The advantages and drawbacks of each of these techniques are discussed. The results obtained from this analysis can be very useful for determining the most adapted technique for a given application. (author)

  13. ELECTRONIC SYSTEM FOR EXPERIMENTATION IN AC ELECTROGRAVIMETRY I: TECHNIQUE FUNDAMENTALS

    Directory of Open Access Journals (Sweden)

    Róbinson Torres

    Full Text Available Basic fundamentals of AC electrogravimetry are introduced. Their main requirements and characteristics are detailed to establish the design of an electronic system that allows the appropriate extraction of data needed to determine the electrogravimetric transfer function (EGTF and electrochemical impedance (EI, in an experimental set-up for the AC electrogravimetry technique.

  14. Progress in wind tunnel experimental techniques for wind turbine?

    Institute of Scientific and Technical Information of China (English)

    Jingping XIAO; Li CHEN; Qiang WANG; Qiao WANG

    2016-01-01

    Based on the unsteady aerodynamics experiment (UAE) phase VI and the model experiment in controlled conditions (MEXICO) projects and the related research carried out in China Aerodynamic Research and Development Center (CARDC), the recent progress in the wind tunnel experimental techniques for the wind turbine is sum-marized. Measurement techniques commonly used for di?erent types of wind tunnel ex-periments for wind turbine are reviewed. Important research achievements are discussed, such as the wind tunnel disturbance, the equivalence of the airfoil in?ow condition, the three-dimensional (3D) e?ect, the dynamic in?ow in?uence, the ?ow ?eld structure, and the vortex induction. The corresponding research at CARDC and some ideas on the large wind turbine are also introduced.

  15. Physiotherapists use a small number of behaviour change techniques when promoting physical activity: A systematic review comparing experimental and observational studies.

    Science.gov (United States)

    Kunstler, Breanne E; Cook, Jill L; Freene, Nicole; Finch, Caroline F; Kemp, Joanne L; O'Halloran, Paul D; Gaida, James E

    2018-06-01

    Physiotherapists promote physical activity as part of their practice. This study reviewed the behaviour change techniques physiotherapists use when promoting physical activity in experimental and observational studies. Systematic review of experimental and observational studies. Twelve databases were searched using terms related to physiotherapy and physical activity. We included experimental studies evaluating the efficacy of physiotherapist-led physical activity interventions delivered to adults in clinic-based private practice and outpatient settings to individuals with, or at risk of, non-communicable diseases. Observational studies reporting the techniques physiotherapists use when promoting physical activity were also included. The behaviour change techniques used in all studies were identified using the Behaviour Change Technique Taxonomy. The behaviour change techniques appearing in efficacious and inefficacious experimental interventions were compared using a narrative approach. Twelve studies (nine experimental and three observational) were retained from the initial search yield of 4141. Risk of bias ranged from low to high. Physiotherapists used seven behaviour change techniques in the observational studies, compared to 30 behaviour change techniques in the experimental studies. Social support (unspecified) was the most frequently identified behaviour change technique across both settings. Efficacious experimental interventions used more behaviour change techniques (n=29) and functioned in more ways (n=6) than did inefficacious experimental interventions (behaviour change techniques=10 and functions=1). Physiotherapists use a small number of behaviour change techniques. Less behaviour change techniques were identified in observational studies compared to experimental studies, suggesting physiotherapists use less BCTs clinically than experimentally. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Equilibrium phase experimental determination of petroleum + gas systems at supercritical condition using ultrasonic technology; Estudo experimental do equilibrio de fases de sistemas de fracoes de petroleo e gases em condicoes supercriticas utilizando tecnicas de ultra-som: aparato experimental

    Energy Technology Data Exchange (ETDEWEB)

    Mehl, Ana; Pessoa, Fernando L.P.; Silva, Silvia M.C. da [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Escola de Quimica; Feiteira, Jose F. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Escola de Engenharia

    2008-07-01

    In separation process of multicomponent systems based on phase equilibrium is essential know the phase behavior and the critical points of the system for determination and optimization of the operational conditions. The experimental apparatus presents the challenge of determine the equilibrium phase dates of a system composed by petroleum residua and supercritical solvent. The used method, named acoustic method, allows the composition identification of the phases in equilibrium also in cloudy systems as they are the systems formed by residues of crude oil. For this reason, the acoustic methodology, based on the ultra-sound technology will be used in the study of the phase equilibrium and experimental characterization of the system, in benches scale, operating in severe conditions of temperature and pressure.The acoustic method is one not invasive and not subjective technique, what becomes the work in high pressures safer. (author)

  17. Multi-gel casting apparatus for vertical polyacrylamide gels with in-built solution flow system and liquid level detectors.

    Science.gov (United States)

    Maurye, Praveen; Basu, Arpita; Bandyopadhyay, Tapas Kumar; Biswas, Jayanta Kumar; Mohanty, Bimal Prasana

    2017-08-01

    PAGE is the most widely used technique for the separation and biochemical analysis of biomolecules. The ever growing field of proteomics and genomics necessitates the analysis of many proteins and nucleic acid samples to understand further about the structure and function of cells. Simultaneous analysis of multiple protein samples often requires casting of many PAGE gels. Several variants of multi-gel casting/electrophoresis apparatuses are frequently used in research laboratories. Requirement of supplementary gels to match the growing demand for analyzing additional protein samples sometimes become a cause of concern. Available apparatuses are not amenable to and therefore, not recommended for any modification to accommodate additional gel casting units other than what is prescribed by the manufacturer. A novel apparatus is described here for casting multiple PAGE gels comprising four detachable components that provide enhanced practicability and performance of the apparatus. This newly modified apparatus promises to be a reliable source for making multiple gels in less time without hassle. Synchronized functioning of unique components broaden the possibilities of developing inexpensive, safe, and time-saving multi-gel casting apparatus. This apparatus can be easily fabricated and modified to accommodate desired number of gel casting units. The estimated cost (∼$300) for fabrication of the main apparatus is very competitive and effortless assembly procedure can be completed within ∼30 min. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Support of nuclear fusion apparatus

    International Nuclear Information System (INIS)

    Watarai, Tetsuo; Ito, Yutaka.

    1975-01-01

    Object: To integrally form a bed for a body for supporting a vacuum container, coil and the like and a bed for a current transformer for supporting the current transformer prior to installation thereof on the floor thereby facilitating assembly and installation. Structure: To provide a base common to a current transformer bed and a body bed without direct installation thereof on the floor. Prior to installation of the current transformer bed and body bed, they are fastened to the base by means of bolts and welded integrally, and the thus formed base is fixed to the floor by means of anchor bolts. Since the current transformer bed and the body bed are formed integrally through the common base, apparatus may easily be carried in and disassembling and re-assembling of apparatus become unnecessary when installed. Further, since the positional relation of the current transformer bed and body bed does not depend on accuracy at the time of installation but depends on accuracy when apparatus manufactured, the toroidal type nuclear fusion apparatus of good accuracy may be obtained. (Yoshihara, H.)

  19. Capillary Condensation of Binary and Ternary Mixtures of n-Pentane-Isopentane-CO2 in Nanopores: An Experimental Study on the Effects of Composition and Equilibrium.

    Science.gov (United States)

    Barsotti, Elizabeth; Saraji, Soheil; Tan, Sugata P; Piri, Mohammad

    2018-02-06

    Confinement in nanopores can significantly impact the chemical and physical behavior of fluids. While some quantitative understanding is available for how pure fluids behave in nanopores, there is little such insight for mixtures. This study aims to shed light on how nanoporosity impacts the phase behavior and composition of confined mixtures through comparison of the effects of static and dynamic equilibrium on experimentally measured isotherms and chromatographic analysis of the experimental fluids. To this end, a novel gravimetric apparatus is introduced and validated. Unlike apparatuses that have been previously used to study the confinement-induced phase behavior of fluids, this apparatus employs a gravimetric technique capable of discerning phase transitions in a wide variety of nanoporous media under both static and dynamic conditions. The apparatus was successfully validated against data in the literature for pure carbon dioxide and n-pentane. Then, isotherms were generated for binary mixtures of carbon dioxide and n-pentane using static and flow-through methods. Finally, two ternary mixtures of carbon dioxide, n-pentane, and isopentane were measured using the static method. While the equilibrium time was found important for determination of confined phase transitions, flow rate in the dynamic method was not found to affect the confined phase behavior. For all measurements, the results indicate qualitative transferability of the bulk phase behavior to the confined fluid.

  20. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  1. Physically-Based Interactive Flow Visualization Based on Schlieren and Interferometry Experimental Techniques

    KAUST Repository

    Brownlee, C.; Pegoraro, V.; Shankar, S.; McCormick, Patrick S.; Hansen, C. D.

    2011-01-01

    Understanding fluid flow is a difficult problem and of increasing importance as computational fluid dynamics (CFD) produces an abundance of simulation data. Experimental flow analysis has employed techniques such as shadowgraph, interferometry

  2. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. A Study on Test Technology to Diagnose the Power Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K H; Kang, Y S; Jeon, Y K; Lee, W Y; Kang, D S; Kyu, H S; Sun, J H; Jo, K H [Korea Electrotechnology Research Institute (Korea, Republic of); Jung, J S; Mun, Y T; Lee, K H; Jung, E H; Kim, J H [Korea Water Resources Corporation (Korea, Republic of)

    1997-02-01

    In this study, we have educated KOWACO(Korea Water Resources Corporation) specialists about the insulation diagnostic technology and trained them the insulation diagnostic test and estimation method of power apparatus. The main results of this study are as follows; A. Education of basic high-voltage engineering. B. Research of insulation characteristic and deterioration mechanism in power apparatus C. Discussion on high-voltage test standard specifications. D. Study on insulation deterioration diagnostics in power apparatus. E. Field testing of insulation diagnosis in power apparatus. F. Engineering of insulation diagnostic testing apparatus to diagnose power apparatus. KOWACO specialists are able to diagnose insulation diagnostic test of power apparatus through this study. As they have instruments to diagnose power apparatus, they can do the test and estimation of the power apparatus insulation diagnosis. (author). refs., figs., tabs.

  4. Apparatus Named after Our Academic Ancestors--I

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2010-01-01

    Let us now praise famous physicists, and the apparatus named after them, with apologies to the writer of Ecclesiastes. I once compiled a list of about 300 pieces of apparatus known to us as X's Apparatus. Some of the values of X are familiar, like Wheatstone and Kelvin and Faraday, but have you heard of Pickering or Rhumkorff or Barlow? In an…

  5. Some manufacture and installation problems in experimental assemblies for fusion research

    International Nuclear Information System (INIS)

    Partridge, J.E.; Rappe, G.; Hoare, F.; McDonald, J.

    1976-01-01

    Many of the manufacturing problems encountered when developing specialised items of fusion apparatus are only solved after much experimentation and a good deal of trial and error. After the experiment is built such problems may be forgotten and are often not recorded so that subsequent workers in the same field may start with no past experience on which to build. The paper therefore highlights some of the manufacturing problems which have been solved during the construction of some of the experimental apparatus at Culham

  6. Spin-polarized hydrogen Rydberg time-of-flight: Experimental measurement of the velocity-dependent H atom spin-polarization

    International Nuclear Information System (INIS)

    Broderick, Bernadette M.; Lee, Yumin; Doyle, Michael B.; Chernyak, Vladimir Y.; Suits, Arthur G.; Vasyutinskii, Oleg S.

    2014-01-01

    We have developed a new experimental method allowing direct detection of the velocity dependent spin-polarization of hydrogen atoms produced in photodissociation. The technique, which is a variation on the H atom Rydberg time-of-flight method, employs a double-resonance excitation scheme and experimental geometry that yields the two coherent orientation parameters as a function of recoil speed for scattering perpendicular to the laser propagation direction. The approach, apparatus, and optical layout we employ are described here in detail and demonstrated in application to HBr and DBr photolysis at 213 nm. We also discuss the theoretical foundation for the approach, as well as the resolution and sensitivity we achieve

  7. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  8. Investigating coseismic fracture damage using a new high speed triaxial apparatus

    Science.gov (United States)

    Mitchell, T. M.; Aben, F. M.; Pricci, R.; Brantut, N.; Rockwell, T. K.; Boon, S.

    2017-12-01

    The occurence of pulverized rocks, a type of intensely damaged fault rock which has undergone minimal shear strain, has been linked to damage induced by transient high strain-rate stress perturbations during earthquake rupture. Damage induced by such transient stresses, whether compressional or tensional, likely constitute heterogeneous modulations of the remote stresses that will impart significant changes on the strength, elastic and fluid flow properties of a fault zone immediately after rupture propagation, at the early stage of fault slip. While the physical mechanisms for pulverized rock generation are still not yet fully understood, it is likely that they are in some way related to a combination of the dynamic compressive and tensional stresses imparted on the rock surrounding a fault at the tip of a propagating earthquake rupture. Typical triaxial rock deformation apparatuses are limited by their loading systems to strain rates on the order of 10-4 s-1, which in terms of the seismic cycle, is only applicable to processes operating within the inter-seismic period. In order to achieve strain rates in excess of 100 s-1 under confined conditions with pore fluids (currently unachievable with conventional deformation apparatus such as split bar Hopkinson), we have designed, manufactured and constructed a new high strain rate triaxial rock deformation apparatus, with a unique innovative hydraulic loading system that allows samples to be deformed in compression and tension at strain rates from 10-7 up to 200 s-1 . We present preliminary data demonstrating the unique capability of this apparatus to produce co-seismic experimental conditions not previously acheived.

  9. Studies on development of experimental system for trial manufacture of semi-field scale lysimeter

    International Nuclear Information System (INIS)

    Kamada, Hiroshi; Yukawa, Masae; Watabe, Teruhisa; Tanaka, Hirobumi; Ohwaku, Keiichi

    1978-01-01

    Because of difficulties in conduct of in situ experiments using the radiotracer method for this purpose, it is necessary to develope the technique on utilization of the results obtained by the laboratory works to resolve phenomenon in the actual environment. For this kind of extrapolation, optimum size of experimental model, designed as large as reasonable in scale to simulate the actual environment (defined as the term, 'semi-field scale experimental model' for convenience) was investigated. For this kind of extrapolation, optimum size of experimental model, designed as large as reasonable in scale to simulate the actual environment (defined as the term, 'semi-field scale experimental model' for convenience) was investigated. For this object, following experiments are especially conducted. The effects of vegetation to the mobility of transition elements in the surface layer of soil was studied by Wagner pot experiment. The vertical movement pattern of radionuclides in the deeper layer in the ground, especially transfer of long-lived-nuclides from soil into water, was investigated using radioactivity survey data of fallout. These results indicated the importance of information on the behaviour of contaminants in 'surface soil', 'Intermediate zone', 'capillary zone' and 'aquifer'. Therefore, an experimental mode, consisted of above four parts, was designed. The apparatus would include several substructures; an artificial rainfall apparatus, the Lysimeter, and receptive basin and so on. A regulation system for the fluctuation of hydraulic gradient in the aquifer would be also required. In order to get information on the above four parts of ground constitutions altogether, approximately 4 - 12 m depth was recommended for the model. (author)

  10. Calibration of a belt apparatus to 1800°C and 6 GPa

    Science.gov (United States)

    Brey, G. P.; Weber, R.; Nickel, K. G.

    1990-09-01

    A belt type solid media high-pressure apparatus has been calibrated to the same accuracy as piston-cylinder apparatuses. This was achieved by ensuring high reproducibility of pressures and temperatures and by calibrating the system with well-established, internally consistent phase transitions. We have used the melting of silver (Mirwald and Kennedy, 1979), the quartz-coesite transition (Mirwald and Masonne, 1980), and the graphite-diamond boundary (Kennedy and Kennedy, 1976). High reproducibility of experimental conditions can be achieved by machining the various components of the furnace assembly very accurately and by using components which do not contaminate the thermocouple and have 99-100% theoretical density (in our case single-crystal MgO and natural polycrystalline CaF2). It is essential that the gasket material has well-defined mechanical properties: its friction behavior must be reproducible in each experiment so that the ram pressure always acts on the pressure vessel and the sample in the same way. Factory-processed pyrophyllite fulfills this requirement. With all precautions taken and on the basis of the reactions cited above, we claim an accuracy of ±7°C and ±(1% nominal pressure+0.05 GPa). This corresponds to the accuracy given by Mirwald et al. (1975) for a low-friction cell for a piston-cylinder apparatus. Our belt apparatus is used routinely to achieve pressures up to 6 GPa and temperatures up to 1800°C.

  11. A new confined high pressure rotary shear apparatus: preliminary results

    Science.gov (United States)

    Faulkner, D.; Coughlan, G.; Bedford, J. D.

    2017-12-01

    The frictional properties of fault zone materials, and their evolution during slip, are of paramount importance for determining the earthquake mechanics of large tectonic faults. Friction is a parameter that is difficult to determine from seismological methods so much of our understanding comes from experiment. Rotary shear apparatuses have been widely used in experimental studies to elucidate the frictional properties of faults under realistic earthquake slip velocities (0.1-10 m/s) and displacements (>20 m). However one technical limitation of rotary shear experiments at seismic slip rates has been the lack of confinement. This has led to a limit on the normal stress (due to the strength of the forcing blocks) and also a lack of control of measurements of the pore fluid pressure. Here we present the first preliminary results from a rotary shear apparatus that has been developed to attempt to address this issue. The new fully confined ring shear apparatus has a fast-acting servo-hydraulic confining pressure system of up to 200 MPa and a servo-controlled upstream and downstream pore pressure system of up to 200 MPa. Displacement rates of 0.01μ/s to 2 m/s can be achieved. Fault gouge samples can therefore be sheared at earthquake speed whilst being subject to pressures typically associated with the depth of earthquake nucleation.

  12. Calculation and experimental technique of determination of rolling procedure for cold-rolling tube mills

    International Nuclear Information System (INIS)

    Igoshin, V.F.; Aleshin, V.A.; Khoroshikh, Yu.G.; Bogatov, A.A.; Mizhiritskij, O.I.

    1983-01-01

    Calculation and experimental technique of determination of tube cold rolling procedure has been developed. Rolling procedure based on the usage of regression equation epsilon=1.24 psi, where psi is the relative reduction of area, delta-permissible reduction during rolling, has been tested on 08Kh18N10T steel. The effect of tube geometry, tool calibration parameters, lubrication conditions etc. on metal deformability in taking into account experimentally. The use of the technique proposed has allowed to shorten the time of mastering of the production of tubes from different steels

  13. APPARATUS FOR ELECTRON BEAM HEATING CONTROL

    Science.gov (United States)

    Jones, W.H.; Reece, J.B.

    1962-09-18

    An improved electron beam welding or melting apparatus is designed which utilizes a high voltage rectifier operating below its temperature saturation region to decrease variations in electron beam current which normally result from the gas generated in such apparatus. (AEC)

  14. Uranium dioxide calcining apparatus

    International Nuclear Information System (INIS)

    Cole, E.A.; Peterson, R.S.

    1978-01-01

    This invention relates to an improved continuous calcining apparatus for consistently and controllably producing from calcinable reactive solid compounds of uranium, such as ammonium diuranate, uranium dioxide (UO 2 ) having an oxygen to uranium ratio of less than 2.2. The apparatus comprises means at the outlet end of a calciner kiln for receiving hot UO 2 , means for cooling the UO 2 to a temperature of below 100 deg C and conveying the cooled UO 2 to storage or to subsequent UO 2 processing apparatus where it finally comes into contact with air, the means for receiving cooling and conveying being sealed to the outlet end of the calciner and being maintained full of UO 2 and so operable as to exclude atmospheric oxygen from coming into contact with any UO 2 which is at elevated temperatures where it would readily oxidize, without the use of extra hydrogen gas in said means. (author)

  15. Radiological diagnosis in constipation and anal incontinence due to changes in the pelvic floor and sphincter apparatus of the anus

    International Nuclear Information System (INIS)

    Bistolfi, F.; Grillo Ruggeri, F.; Siragusa, A.

    1987-01-01

    Rectal constipation, anal incontinence and constipation combined with incontinence, are often caused by organic or simply functional changes in the pelvic floor and sphincterial apparatus. Therefore morphological as well as manometric and electromyographic studies of these anatomical parts are required. This is possible by combining two techniques: Intestinal Transit Time (ITT) and Defecatory Proctogram with Balloon (DPB). Personal experience of 38 patients with constipation with or without incontinence is reported. The results lead to the following conclusion: 1) ITT is a simple and non-invasive radiological technique that provides us with objective evidence of an impairment, i.e. constipation, whose symptoms are often only subjective; especially is allows us to identify rectal constipation, that can be caused by impairment of the anal sphincteral apparatus. 2) Using an uroprophylactic with a collar that adapts to the size of the anal duct, DPB always permits visualization of the duct with good representation of the recto-anal angle, whose changes may be the expression of organic or only functional impairments of the anal sphincterial apparatus. Increasing use of the two radiological techniques is therefore recommended in the diagnosis of alterations of the pelvic floor or anal sphincter

  16. Laser-based irradiation apparatus and methods for monitoring the dose-rate response of semiconductor devices

    Science.gov (United States)

    Horn, Kevin M [Albuquerque, NM

    2006-03-28

    A scanned, pulsed, focused laser irradiation apparatus can measure and image the photocurrent collection resulting from a dose-rate equivalent exposure to infrared laser light across an entire silicon die. Comparisons of dose-rate response images or time-delay images from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems allows precise identification of those specific age-affected circuit structures within a device that merit further quantitative analysis with targeted materials or electrical testing techniques. Another embodiment of the invention comprises a broad-beam, dose rate-equivalent exposure apparatus. The broad-beam laser irradiation apparatus can determine if aging has affected the device's overall functionality. This embodiment can be combined with the synchronized introduction of external electrical transients into a device under test to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure.

  17. Flow cytometry: design, development and experimental validation

    International Nuclear Information System (INIS)

    Seigneur, Alain

    1987-01-01

    The flow cytometry techniques allow the analysis and sorting of living biologic cells at rates above five to ten thousand events per second. After a short review, we present in this report the design and development of a 'high-tech' apparatus intended for research laboratories and the experimental results. The first part deals with the physical principles allowing morphologic and functional analysis of cells or cellular components. The measured parameters are as follows: electrical resistance pulse sizing, light scattering and fluorescence. Hydrodynamic centering is used, and in the same way, the division of a water-stream into droplets leading to electrostatic sorting of particles. The second part deals with the apparatus designed by the 'Commissariat a l'Energie Atomique' (C.E.A.) and industrialised by 'ODAM' (ATC 3000). The last part of this thesis work is the performance evaluations of this cyto-meter. The difference between the two size measurement methods are analyzed: electrical resistance pulse sizing versus small-angle light scattering. By an original optics design, high sensitivity has been reached in the fluorescence measurement: the equivalent noise corresponds to six hundred fluorescein isothiocyanate (FITC) molecules. The sorting performances have also been analyzed and the cell viability proven. (author) [fr

  18. 21 CFR 868.5165 - Nitric oxide administration apparatus.

    Science.gov (United States)

    2010-04-01

    ... apparatus. (a) Identification. The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be used in conjunction with a ventilator or other breathing gas administration system. (b) Classification...

  19. Dosimeter charging apparatus

    International Nuclear Information System (INIS)

    Reuter, F.A.; Moorman, Ch.J.

    1985-01-01

    An apparatus for charging a dosimeter which has a capacitor connected between first and second electrodes and a movable electrode in a chamber electrically connected to the first electrode. The movable electrode deflects varying amounts depending upon the charge present on said capacitor. The charger apparatus includes first and second charger electrodes couplable to the first and second dosimeter electrodes. To charge the dosimeter, it is urged downwardly into a charging socket on the charger apparatus. The second dosimeter electrode, which is the dosimeter housing, is electrically coupled to the second charger electrode through a conductive ring which is urged upwardly by a spring. As the dosimeter is urged into the socket, the ring moves downwardly, in contact with the second charger electrode. As the dosimeter is further urged downwardly, the first dosimeter electrode and first charger electrode contact one another, and an insulator post carrying the first and second charger electrodes is urged downwardly. Downward movement of the post effects the application of a charging potential between the first and second charger electrodes. After the charging potential has been applied, the dosimeter is moved further into the charging socket against the force of a relatively heavy biasing spring until the dosimeter reaches a mechanical stop in the charging socket

  20. Experimental equipment for an advanced ISOL facility

    International Nuclear Information System (INIS)

    Baktash, C.; Lee, I.Y.; Rehm, K.E.

    1999-01-01

    This report summarizes the proceedings and recommendations of the Workshop on the Experimental Equipment for an Advanced ISOL Facility which was held at Lawrence Berkeley National Laboratory on July 22--25, 1998. The purpose of this workshop was to discuss the performance requirements, manpower and cost estimates, as well as a schedule of the experimental equipment needed to fully exploit the new physics which can be studied at an advanced ISOL facility. An overview of the new physics opportunities that would be provided by such a facility has been presented in the White Paper that was issued following the Columbus Meeting. The reactions and experimental techniques discussed in the Columbus White Paper served as a guideline for the formulation of the detector needs at the Berkeley Workshop. As outlined a new ISOL facility with intense, high-quality beams of radioactive nuclei would provide exciting new research opportunities in the areas of: the nature of nucleonic matter; the origin of the elements; and tests of the Standard Model. After an introductory section, the following equipment is discussed: gamma-ray detectors; recoil separators; magnetic spectrographs; particle detectors; targets; and apparatus using non-accelerated beams

  1. Hydraulic Apparatus for Mechanical Testing of Nuts

    Science.gov (United States)

    Hinkel, Todd J.; Dean, Richard J.; Hacker, Scott C.; Harrington, Douglas W.; Salazar, Frank

    2004-01-01

    The figure depicts an apparatus for mechanical testing of nuts. In the original application for which the apparatus was developed, the nuts are of a frangible type designed for use with pyrotechnic devices in spacecraft applications in which there are requirements for rapid, one-time separations of structures that are bolted together. The apparatus can also be used to test nonfrangible nuts engaged without pyrotechnic devices. This apparatus was developed to replace prior testing systems that were extremely heavy and immobile and characterized by long setup times (of the order of an hour for each nut to be tested). This apparatus is mobile, and the setup for each test can now be completed in about five minutes. The apparatus can load a nut under test with a static axial force of as much as 6.8 x 10(exp 5) lb (3.0 MN) and a static moment of as much as 8.5 x 10(exp 4) lb in. (9.6 x 10(exp 3) N(raised dot)m) for a predetermined amount of time. In the case of a test of a frangible nut, the pyrotechnic devices can be exploded to break the nut while the load is applied, in which case the breakage of the nut relieves the load. The apparatus can be operated remotely for safety during an explosive test. The load-generating portion of the apparatus is driven by low-pressure compressed air; the remainder of the apparatus is driven by 110-Vac electricity. From its source, the compressed air is fed to the apparatus through a regulator and a manually operated valve. The regulated compressed air is fed to a pneumatically driven hydraulic pump, which pressurizes oil in a hydraulic cylinder, thereby causing a load to be applied via a hydraulic nut (not to be confused with the nut under test). During operation, the hydraulic pressure is correlated with the applied axial load, which is verified by use of a load cell. Prior to operation, one end of a test stud (which could be an ordinary threaded rod or bolt) is installed in the hydraulic nut. The other end of the test stud passes

  2. Radiative Gasification Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This apparatus, developed at EL, determines gasification rate (mass loss rate) of a horizontally oriented specimen exposed in a nitrogen environment to a controlled...

  3. Electroplating method and apparatus

    International Nuclear Information System (INIS)

    Looney, R.B.; Smith, W.E.L.

    1978-01-01

    Disclosed is an apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm

  4. Electroplating method and apparatus

    Science.gov (United States)

    Looney, Robert B.; Smith, William E. L.

    1978-06-20

    An apparatus for high speed electroplating or anodizing tubular members such as nuclear reactor fuel elements. A loading arm positions the member on a base for subsequent support by one of two sets of electrical contacts. A carriage assembly positions electrodes into and around the member. Electrolyte is pumped between the electrodes and the member while electric current is applied. Programmed controls sequentially employ each of the two sets of contacts to expose all surfaces of the member to the electrolyte. The member is removed from the apparatus by an unloading arm.

  5. The Acoustical Apparatus of Rudolph Koenig.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1992-01-01

    Discusses the history of Rudolph Koenig's contribution to the development of acoustical apparatus. Contributions include the clock fork to determine absolute acoustic frequencies, a forerunner of the oscilloscope called the manometric flame, and an acoustic interference apparatus used in the Fourier synthesis of musical sounds. (MDH)

  6. BROACHING AND TUBE-INSTALLING APPARATUS

    Science.gov (United States)

    Frantz, C.E.; Cawley, W.E.

    1961-05-16

    An apparatus is given for sizing long holes in graphite bodies. The apparatus comprises a shaft having 3 spiral broach cutting elements and a straight broach cutting element rotatably mounted thereon. The broach cutting elements are keyed to each other in end to end relationship with the straight broach cutting element at one end of the shaft. The spiral broach cutting elements when considered toward the straight broach cutting element increase in diameter and the cutting teeth thereon increase in lead angle. The straight broach cutting element, when considered in the same direction, increases in diameter from the minimum to maximum diameters of the spiral broach cutting elements. No longitudinal movement of the broach cutting elements is permitted on the shsft snd means are provided for the removal of chips from the apparatus.

  7. A robust calibration technique for acoustic emission systems based on momentum transfer from a ball drop

    Science.gov (United States)

    McLaskey, Gregory C.; Lockner, David A.; Kilgore, Brian D.; Beeler, Nicholas M.

    2015-01-01

    We describe a technique to estimate the seismic moment of acoustic emissions and other extremely small seismic events. Unlike previous calibration techniques, it does not require modeling of the wave propagation, sensor response, or signal conditioning. Rather, this technique calibrates the recording system as a whole and uses a ball impact as a reference source or empirical Green’s function. To correctly apply this technique, we develop mathematical expressions that link the seismic moment $M_{0}$ of internal seismic sources (i.e., earthquakes and acoustic emissions) to the impulse, or change in momentum $\\Delta p $, of externally applied seismic sources (i.e., meteor impacts or, in this case, ball impact). We find that, at low frequencies, moment and impulse are linked by a constant, which we call the force‐moment‐rate scale factor $C_{F\\dot{M}} = M_{0}/\\Delta p$. This constant is equal to twice the speed of sound in the material from which the seismic sources were generated. Next, we demonstrate the calibration technique on two different experimental rock mechanics facilities. The first example is a saw‐cut cylindrical granite sample that is loaded in a triaxial apparatus at 40 MPa confining pressure. The second example is a 2 m long fault cut in a granite sample and deformed in a large biaxial apparatus at lower stress levels. Using the empirical calibration technique, we are able to determine absolute source parameters including the seismic moment, corner frequency, stress drop, and radiated energy of these magnitude −2.5 to −7 seismic events.

  8. Apparatus and method for nuclear magnetic resonance scanning and mapping

    International Nuclear Information System (INIS)

    Damadian, R.V.

    1983-01-01

    An improved apparatus and method is disclosed for analyzing the chemical and structural composition of a specimen including whole-body specimens which may include, for example, living mammals, utilizing nuclear magnetic resonance (NMR) techniques. A magnetic field space necessary to obtain an NMR signal characteristic of the chemical structure of the specimen is focused to provide a resonance domain of selectable size, which may then be moved in a pattern with respect to the specimen to scan the specimen

  9. Technique of experimental evaluation of cloud environment attacks detection accuracy

    Directory of Open Access Journals (Sweden)

    Sergey A. Klimachev

    2018-05-01

    Full Text Available The article is devoted to research of efficiency evaluation of IDS used for dynamic and complex organizational and technical structure computing platform guard. The components of the platform have a set of heterogeneous parameters. Analysis of existing IDS evaluation technique revealed shortcomings in justification of quantitative metrics that describe the efficiency and reliability IDS resolving. This makes if difficult to prove IDS evaluation technique. The purpose of the study is to increase IDS evaluation objectivity. To achive the purpose it is necessary to develop the correct technique, tools, experimental stand. The article proposes the results of development and approbation of the technique of IDS efficiency evaluation and software for it. The technique is based on defining of optimal set of attack detection accuracy scores. The technique and the software allow solving problems of comparative analysis of IDS that have similar functionality. As a result of the research, a number of task have been solved, including the selection of universal quantitative metrics for attack detection accuracy evaluation, the defining of summarised attack detection accuracy evaluation metric based on defining of pareto-optimal set of scores that ensure the confidentiality, integrity and accessibility of cloud environment information and information resources,  the development of a functional model,  a functional scheme and a software for cloud environment IDS research.

  10. Monitoring apparatus

    International Nuclear Information System (INIS)

    Keats, A.B.

    1981-01-01

    An improved monitoring apparatus for use with process plants, such as nuclear reactors, is described. System failure in the acquisition of data from the plant, owing to stuck signals, is avoided by arranging input signals from transducers in the plant in a test pattern. (U.K.)

  11. 47 CFR 32.2311 - Station apparatus.

    Science.gov (United States)

    2010-10-01

    ... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2311 Station apparatus... company shall prepare a list of station apparatus which shall be used as its list of disposition units for... technicians, and others, shall be included in Account 2114, Tools and other work equipment, Account 2220...

  12. Technical note: CT-guided biopsy of lung masses using an automated guiding apparatus

    International Nuclear Information System (INIS)

    Chellathurai, Amarnath; Kanhirat, Saneej; Chokkappan, Kabilan; Swaminathan, Thiruchendur S; Kulasekaran, Nadhamuni

    2009-01-01

    Automated guiding apparatuses for CT-guided biopsies are now available. We report our experience with an indigenous system to guide lung biopsies. This system gave results similar to those with the manual technique. Automated planning also appears to be technically easier, it requires fewer number of needle passes, consumes less time, and requires fewer number of check scans

  13. low-cost apparatus from locally available materials for teaching

    African Journals Online (AJOL)

    unesco

    twofold: i) to design and produce appropriate low cost apparatus from locally .... How are the low-cost and manufactured apparatus compared in terms of cost and efficiency? ... BASIC TOOLS FOR THE LOW COST APPARATUS PRODUCTION.

  14. Experimental Verification of Interference Mitigation Techniques for 5G Small Cells

    DEFF Research Database (Denmark)

    Assefa, Dereje; Berardinelli, Gilberto; Tavares, Fernando Menezes Leitão

    2015-01-01

    deployment with four cells, where each cell features one Access Point (AP) and one User Equipment (UE). In particular, we compare traditional Frequency Reuse Planning (FRP) with the recently proposed Maximum Rank Planning (MRP) technique, which relies on the degrees of freedom offered by the multi...... with the USRP N200 hardware by Ettus Research. The experimental results in a fully loaded network reveal the capability of the MRP technique to achieve higher throughput performance than FRP for 90% of the cases when IRC receivers are used. Lower network loads lead to further performance improvements for MRP....

  15. Simulation and experimental validation of the performance of a absorption refrigerator

    International Nuclear Information System (INIS)

    Olbricht, Michael; Luke, Andrea

    2015-01-01

    The two biggest obstacles to a stronger market penetration of absorption refrigerators are their high cost and the size of the apparatus, which are due to the inaccurate methods for plant design. In order to contribute to an improved design a thermodynamic model is presented to describe the performance of a absorption refrigerator with the working fluid water/lithium. In this model, the processes are displayed in the single apparatus and coupled to each other in the systemic context. Thereby the interactions between the apparatus can specifically investigated and thus the process limiting component can be identified under the respective conditions. A validation of the simulation model and the boundary conditions used is done based on experimental data operating a self-developed absorption refrigerator. In the simulation, the heat transfer surfaces in accordance with the real system can be specified. The heat transport is taken into account based on typical values for the heat transfer in the individual apparatuses. Simulation results show good agreement with the experimental data. The physical relationships and influences externally defined operating parameters are correctly reproduced. Due to the chosen low heat transfer coefficient, the calculated cooling capacities by the model are below the experimentally measured. Finally, the possibilities and limitations are discussed by using the model and further improvement possibilities are suggested. [de

  16. Study of poli (ethylene tereftalate) thin films submitted to radiations by using permeation and spectroscopic techniques

    International Nuclear Information System (INIS)

    Andrade, L.A.

    1986-06-01

    Properties of poly (ethylene terephthalate P.E.T. thin films submitted to electric discharges, electron, He + ion and proton beams were investigated using permeation technique, electronic paramagnetic resonance resonance (E.P.R.) and visible and infrared spectroscopies. Experimental apparatuses and procedures are described and the results of the analyses are presented and discussed. The existence of structural modifications in irradiated P.E.T. thin films is confirmed. It is shown that the kind of effects occuring in irradiated P.E.T. depends on the nature of the incident radiation. (author) [pt

  17. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  18. Positioning calibration apparatus for transducers employed in nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Elsner, H.J.

    1981-01-01

    The invention provides a calibration apparatus suitable for verifying the position and orientation of transducers used in reactor vessel ultrasonic inspection. The apparatus includes moveable mounting means which secures a transducer within the tank in its normal inspection orientation. A drive is also provided for moving the transducer in the tank relative to a target. The target is slidably positioned in the tank at a distance from the transducer which is selected to avoid the distortion effects in the near field of the transducer. The drive mechanism may be provided with graduated indicia of travel, or a scale may be affixed to the side of the tank. (L.L.)

  19. A cyber-physical approach to experimental fluid mechanics

    Science.gov (United States)

    Mackowski, Andrew Williams

    This Thesis documents the design, implementation, and use of a novel type of experimental apparatus, termed Cyber-Physical Fluid Dynamics (CPFD). Unlike traditional fluid mechanics experiments, CPFD is a general-purpose technique that allows one to impose arbitrary forces on an object submerged in a fluid. By combining fluid mechanics with robotics, we can perform experiments that would otherwise be incredibly difficult or time-consuming. More generally, CPFD allows a high degree of automation and control of the experimental process, allowing for much more efficient use of experimental facilities. Examples of CPFD's capabilites include imposing a gravitational force in the horizontal direction (allowing a test object to "fall" sideways in a water channel), simulating nonlinear springs for a vibrating fluid-structure system, or allowing a self-propelled body to move forward under its own force. Because experimental parameters (including forces and even the mass of the test object) are defined in software, one can define entire ensembles of experiments to run autonomously. CPFD additionally integrates related systems such as water channel speed control, LDV flow speed measurements, and PIV flowfield measurements. The end result is a general-purpose experimental system that opens the door to a vast array of fluid-structure interaction problems. We begin by describing the design and implementation of CPFD, the heart of which is a high-performance force-feedback control system. Precise measurement of time-varying forces (including removing effects of the test object's inertia) is more critical here than in typical robotic force-feedback applications. CPFD is based on an integration of ideas from control theory, fluid dynamics, computer science, electrical engineering, and solid mechanics. We also describe experiments using the CPFD experimental apparatus to study vortex-induced vibration (VIV) and oscillating-airfoil propulsion. We show how CPFD can be used to simulate

  20. Substantiation of health related power lifting training methodic for univeristies students with muscular skeletal apparatuse affections.

    Directory of Open Access Journals (Sweden)

    San. Zhen Qiang

    2015-11-01

    Full Text Available Purpose: substantiation of health related power lifting training methodic for universities students, who have disorders of muscular skeletal apparatus. Material: in experimental researches 126 students of 18-24 years’ age, having disorders of muscular skeletal apparatus, participated. With the help of testing we registered changes of students’ functional, physical and psycho-physiological fitness indicators. Results: optimal correlation of specific and non specific loads was found: 60% of specific and 40% of non specific. It is recommended to follow certain correlation of exercises in easy and complicated conditions: for first year students - 3:2; for second year students - 3:2; for third year - 2:3; for forth year - 2:3; for fifth year students - 1:3. Specific only for power lifting conditions and temps of students’ (with muscular skeletal apparatus affections functional, physical and psycho-physiological fitness improvement were determined. Conclusions: The requirements of the training methodic envisage correction of loads for bringing every indicator on proper level.

  1. Experimental Modeling of Sterilization Effects for Atmospheric Entry Heating on Microorganisms

    Science.gov (United States)

    Schubert, Wayne W.; Spry, James A.; Ronney, Paul D.; Pandian, Nathan R.; Welder, Eric

    2012-01-01

    The objective of this research was to design, build, and test an experimental apparatus for studying the parameters of atmospheric entry heating, and the inactivation of temperature-resistant bacterial spores. The apparatus is capable of controlled, rapid heating of sample coupons to temperatures of 200 to 350 C and above. The vacuum chamber permits operation under vacuum or special atmospheric gas mixtures.

  2. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  3. Apparatus for washing out halogens

    Energy Technology Data Exchange (ETDEWEB)

    Pier, M; Hahn, J; Kroenig, W

    1941-03-26

    An apparatus is described for washing out of halogens and the like or liquid halogen compounds from the products, which are formed on pressure hydrogenation or splitting of carbon-containing material in the presence of halogens or halogen compounds, consisting of a washing apparatus installed between the reaction vessel and the hot separator, which is inclined in relatively small space for steam regulation and contains, with the steam, arranged baffles, especially spirals.

  4. On the metaphysics of experimental physics

    CERN Document Server

    Rogers, K

    2005-01-01

    This provocative and critical work addresses the question of why scientific realists and positivists consider experimental physics to be a natural and empirical science. Taking insights from contemporary science studies, continental philosophy, and the history of physics, this book describes and analyses the metaphysical presuppositions that underwrite the technological use of experimental apparatus and instruments to explore, model, and understand nature. By revealing this metaphysical foundation, the author questions whether experimental physics is a natural and empirical science at all.

  5. Apparatus and Experimental Procedures to Test Crystal Collimation

    CERN Document Server

    Montesano, S

    2012-01-01

    UA9 is an experimental setup operated in the CERN-SPS in view of investigating the feasibility of halo collimation assisted by bent crystals. The test collimation system is composed of one crystal acting as primary halo deflector in the horizontal plane and an absorber. Different crystals are tested in turn using two-arm goniometers with an angular reproducibility of better than 10 microrad. The performance of the system is assessed through the study of the secondary and tertiary halo in critical areas, by using standard machine instrumentation and few customized equipments. The alignment of the crystal is verified by measuring the loss rate close to the crystal position. The collimation efficiency is computed by intercepting the deflected halo with a massive collimator or with an imaging device installed into a Roman Pot. The leakage of the system is evaluated in the dispersion suppressor by means of movable aperture restrictions. In this contribution the setup and the experimental methods in use are revisit...

  6. Method and apparatus for measuring underground fluid flow characteristics

    International Nuclear Information System (INIS)

    Paap, H.J.; Richter, A.P.; Peelman, H.E.; Arnold, D.M.; Scot, H.D.

    1979-01-01

    This invention relates to the use of neutron activation techniques to measure the azimuth and speed of the horizontal fluid flow in earth formations in the vicinity of a well borehole and the analysis of the resultant gamma radiation based on count rate data obtained as functions of horizontal direction and time. The apparatus consisting of a sonde (a downhole well logging tool) equipped with a neutron source, a gamma detector and a rotatable shield with collimator slot and the data processing equipment located at the surface, are described. (UK)

  7. Experimental perspectives in low energy lepton physics

    International Nuclear Information System (INIS)

    Fiorini, E.

    1986-01-01

    Low energy nuclear physics has been and is going to be an essential tool for the study of weak interaction and neutrino physics. The use of the atomic nucleus as a ''microlaboratory'' with well defined quantum numbers is undoubtedly going to yield important and sometimes perhaps unexpected results on the symmetry laws governing the subnuclear world. These searches are however very hard experimentally and the bottleneck on obtaining more stringent results only rarely depends on the need of large and expensive apparatuses as those used in high energy physics: more limiting are technical difficulties. The author believes therefore that a real break-through to overcome the present experimental limitations can only be obtained with totally new and sometime ''non canonical'' technical approaches. This paper is an admittedly incomplete discussion of some of them. The author considers separately searches for rare decays, detection of low energy neutrinos and measurements of the neutrino mass, even if some of these new techniques are common to more than one of these subjects

  8. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  9. Thermal expansion and density measurements of molten and solid materials at high temperatures by the gamma attenuation technique

    International Nuclear Information System (INIS)

    Drotning, W.D.

    1979-05-01

    An apparatus is described for the measurement of the density and thermal expansion of molten materials to 3200 0 K using the gamma attenuation technique. The precision of the experimental technique was analytically examined for both absolute and relative density determinations. Three analytical expressions used to reduce data for liquid density determinations were evaluated for their precision. Each allows use of a different set of input data parameters, which can be chosen based on experimental considerations. Using experimentally reasonable values for the precision of the parameters yields a similar resultant density precision from the three methods, on the order of 0.2%. The analytical method for measurements of the linear thermal expansion of solids by the gamma method is also described. To demonstrate the use of the technique on reasonably well-characterized systems, data are presented for (1) the density and thermal expansion of molten tin, lead, and aluminum to 1300 0 K, (2) the thermal expansion of solid aluminum to the melting point, and (3) the thermal expansion of a low melting point glass through the transition temperature and melting region. The data agree very well with published results using other methods where such published data exist

  10. WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dadkhah, H; Wu, X [University of Iowa, Iowa City, Iowa (United States); Kim, Y; Flynn, R [University of Iowa Hospitals and Clinics, Iowa City, IA (United States)

    2016-06-15

    Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls as well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible

  11. Experimental Study on Corrosion Detection of Aluminum Alloy Using Lamb Wave Mixing Technique

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Heeung; Lee, Jaesun; Cho, Younho [Pusan Nat’l Univ., Busan (Korea, Republic of)

    2016-11-15

    In this study, the Lamb wave mixing technique, which is basised on advanced research on the nonlinear bulk wave mixing technique, is applied for corrosion detection. To demonstrate the validity of the Lamb wave mixing technique, an experiment was performed with normal and corroded specimens. Comparison group in an experimentation are selected to mode and frequency with dominant in-plane displacement and out-of-plane displacement of Lamb waves. The results showed that the Lamb wave mixing technique can monitor corrosion defects, and it has a trend similar to that of the conventional Lamb wave technique. It was confirmed that the dominant displacement and mode matching the theory were generated. Flaw detectability is determined depending on displacement ratio instead of using the measurement method and mode selection.

  12. Experimental techniques for characterising water in wood covering the range from dry to fully water-saturated

    DEFF Research Database (Denmark)

    Thybring, Emil Engelund; Kymäläinen, Maija; Rautkari, Lauri

    2018-01-01

    focuses on selected experimental techniques that can give deeper insights into various aspects of water in wood in the entire moisture domain from dry to fully water-saturated. These techniques fall into three broad categories: (1) gravimetric techniques that determine how much water is absorbed, (2...

  13. Biofilm Formation Derived from Ambient Air and the Characteristics of Apparatus

    International Nuclear Information System (INIS)

    Kanematsu, H; Kougo, H; Kuroda, D; Itho, H; Ogino, Y; Yamamoto, Y

    2013-01-01

    Biofilm is a kind of thin film on solidified matters, being derived from bacteria. Generally, planktonic bacteria float in aqueous environments, soil or air, most of which can be regarded as oligotrophic environments. Since they have to survive by instinct, they seek for nutrients that would exist on materials surfaces as organic matters. Therefore, bacteria attach materials surfaces reversibly. The attachment and detachment repeat for a while and finally, they attach on them irreversibly and the number of bacteria on them increases. At a threshold number, bacteria produce polymeric matters at the same time by quorum sensing mechanism and the biofilm produces on material surfaces. The biofilm produced in that way generally contains water (more than 80%), EPS (Exopolymeric Substance) and bacteria themselves. And they might bring about many industrial problems, fouling, corrosion etc. Therefore, it is very important for us to control and prevent the biofilm formation properly. However, it is generally very hard to produce biofilm experimentally and constantly in ambient atmosphere on labo scale. The authors invented an apparatus where biofilm could form on specimen's surfaces from house germs in the ambient air. In this experiment, we investigated the basic characteristics of the apparatus, reproducibility, the change of biofilm with experimental time, the quality change of water for biofilm formation and their significance for biofilm research.

  14. Experimental Route to Scanning Probe Hot Electron Nanoscopy (HENs) Applied to 2D Material

    KAUST Repository

    Giugni, Andrea

    2017-06-09

    This paper presents details on a new experimental apparatus implementing the hot electron nanoscopy (HENs) technique introduced for advanced spectroscopies on structure and chemistry in few molecules and interface problems. A detailed description of the architecture used for the laser excitation of surface plasmons at an atomic force microscope (AFM) tip is provided. The photogenerated current from the tip to the sample is detected during the AFM scan. The technique is applied to innovative semiconductors for applications in electronics: 2D MoS2 single crystal and a p-type SnO layer. Results are supported by complementary scanning Kelvin probe microscopy, traditional conductive AFM, and Raman measurements. New features highlighted by HEN technique reveal details of local complexity in MoS2 and polycrystalline structure of SnO at nanometric scale otherwise undetected. The technique set in this paper is promising for future studies in nanojunctions and innovative multilayered materials, with new insight on interfaces.

  15. Apparatus for filtering radioactive fluids

    International Nuclear Information System (INIS)

    Gischel, E.H.

    1975-01-01

    Apparatus is provided for filtering radioactive particles from the cooling and/or auxiliary process water of a nuclear reactor, or nuclear fuel processing plant, or other installations wherein radioactive fluid systems are known to exist. The apparatus affords disposal of the captured particles in a manner which minimizes the exposure of operating personnel to radioactivity. The apparatus comprises a housing adapted to contain a removable filter cartridge assembly, a valve normally closing the lower end of the housing, an upwardly-open shipping cask located below the valve, and an elongated operating rod assembly projecting upwardly from the filter cartridge assembly and through the upper end of the housing to enable a workman to dismount the filter cartridge assembly from its housing and to lower the filter cartridge assembly through the valve and into the cask from a remote location above the housing. (U.S.)

  16. Matrix isolation sublimation: An apparatus for producing cryogenic beams of atoms and molecules

    Energy Technology Data Exchange (ETDEWEB)

    Sacramento, R. L.; Alves, B. X.; Silva, B. A.; Wolff, W.; Cesar, C. L. [Instituto de Física, Universidade Federal do Rio de Janeiro, Caixa Postal 68528, 21941-972 Rio de Janeiro, RJ (Brazil); Oliveira, A. N. [Instituto de Física, Universidade Federal do Rio de Janeiro, Caixa Postal 68528, 21941-972 Rio de Janeiro, RJ (Brazil); INMETRO, Av. Nossa Senhora das Graças, 50 25250-020 Duque de Caxias, RJ (Brazil); Li, M. S. [Instituto de Física de São Carlos, Universidade de São Paulo, Ave. Trabalhador São Carlense, 400, 13565-590 São Carlos, SP (Brazil)

    2015-07-15

    We describe the apparatus to generate cryogenic beams of atoms and molecules based on matrix isolation sublimation. Isolation matrices of Ne and H{sub 2} are hosts for atomic and molecular species which are sublimated into vacuum at cryogenic temperatures. The resulting cryogenic beams are used for high-resolution laser spectroscopy. The technique also aims at loading atomic and molecular traps.

  17. Fundamental aspects of oily waters treatment from the mineral industries by electrolytic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Merma, A.G.; Gonzales, L.V.; Torem, M.L. [Pontifical Catholic Univ. of Rio de Janeiro, Rio de Janeiro (Brazil). Dept. of Materials Engineering

    2010-07-01

    There is an immediate need to develop innovative and more effective techniques for treatment of wastewaters as regulations on effluent wastewater discharge are becoming increasingly prevalent. The mining and metallurgical industries generate wastewaters that contain stable oil-in-water emulsions, arising from residues of liquid streams that serve the purpose of lubrication, cooling, cleaning and corrosion prevention in the equipment used in those industries. Chemically stabilized oil-water emulsions produced in the mineral industries can be treated using an electrocoagulation technique that considers the effects of operating parameters such as initial pH, current density, reaction time, electrode area/liquid volume ratio and electrode materials on the separation of oil as measured by the chemical oxygen demand. The paper discussed electrocoagulation as well as the materials and methods for the study, including oil in water emulsions; the experimental apparatus; and the experimental procedure. It was concluded that the electrolysis of this kind of oil in water emulsions with aluminum electrodes resulted in pH neutralization regardless of the initial pH tested. 18 refs., 4 figs.

  18. Process and apparatus for cracking petroleum, etc

    Energy Technology Data Exchange (ETDEWEB)

    1931-04-25

    Process for catalytic cracking of petroleum and similar material at normal pressure, characterized by the oil vaporized in a vaporizer being treated in a first catalyst-chamber and in a separator attached to it, light constituents being separated, and then its being run into a second apparatus-group (vaporizer, catalyst-chamber, and separator), further groups following in series, whereby the catalyst works in a separate catalyst apparatus with ever-increasing activity time on the always lesser but always more difficult to crack material, so that in the whole apparatus a methodical cracking process is effected.

  19. Apparatus for concentrating by dual temperature exchange

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1975-01-01

    Improvements in an apparatus for isotope concentration by dual temperature exchange between feed and auxiliary fluids in a multistage system are described. The first fluid is a vaporizable liquid and the auxiliary fluid a gas, the apparatus having means for cascading the auxiliary fluid and the feed fluid in vapor and preferably also in liquid form. The apparatus also contains new combinations of means for improving the heating and/or cooling and/or humidifying and/or dehumidifying operations of the system. The reactants in the example given are hydrogen sulfide gas and liquid water

  20. Method and apparatus for producing microspherical particles

    International Nuclear Information System (INIS)

    Egli, W.; Bailey, W.H.; Leary, D.F.; Lansley, R.J.

    1979-01-01

    This invention relates generally to a method and apparatus for producing microspherical particles and more particularly to a method and apparatus which are particularly useful in connection with the sol-gel process for the production of nuclear fuel kernels. (U.K.)

  1. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  2. An apparatus for the determination of speeds of sound in fluids

    International Nuclear Information System (INIS)

    Gedanitz, Holger; Davila, Maria J.; Baumhoegger, Elmar; Span, Roland

    2010-01-01

    An apparatus for accurate measurements of the sound velocity in fluids is described, which is based on the pulse-echo technique, and operates up to 30 MPa in the temperature range between (250 and 350) K. The expanded uncertainties (k = 2) in the speed of sound measurements are 0.006%, 6 mK in the temperature, 2.1 hPa in the pressure up to 3 MPa, and 23.9 hPa above this value. Measurements of the speed of sound for nitrogen from (250 to 350) K and for water at temperatures between (303.15 and 323.15) K are presented at pressures up to 30 MPa to validate the new apparatus. The expanded overall uncertainty of the measurements on nitrogen and water were estimated to be 0.011% and 0.006%, respectively. The speed of sound of both fluids was compared with literature sources showing an excellent agreement among them, with relative deviations lower than 0.01% in nitrogen and 0.006% in water.

  3. Two-dimensional heat flow apparatus

    Science.gov (United States)

    McDougall, Patrick; Ayars, Eric

    2014-06-01

    We have created an apparatus to quantitatively measure two-dimensional heat flow in a metal plate using a grid of temperature sensors read by a microcontroller. Real-time temperature data are collected from the microcontroller by a computer for comparison with a computational model of the heat equation. The microcontroller-based sensor array allows previously unavailable levels of precision at very low cost, and the combination of measurement and modeling makes for an excellent apparatus for the advanced undergraduate laboratory course.

  4. Front lighted optical tooling method and apparatus

    International Nuclear Information System (INIS)

    Stone, W. J.

    1985-01-01

    An optical tooling method and apparatus uses a front lighted shadowgraphic technique to enhance visual contrast of reflected light. The apparatus includes an optical assembly including a fiducial mark, such as cross hairs, reflecting polarized light with a first polarization, a polarizing element backing the fiducial mark and a reflective surface backing the polarizing element for reflecting polarized light bypassing the fiducial mark and traveling through the polarizing element. The light reflected by the reflecting surface is directed through a second pass of the polarizing element toward the frontal direction with a polarization differing from the polarization of the light reflected by the fiducial mark. When used as a tooling target, the optical assembly may be mounted directly to a reference surface or may be secured in a mounting, such as a magnetic mounting. The optical assembly may also be mounted in a plane defining structure and used as a spherometer in conjunction with an optical depth measuring instrument. A method of measuring a radius of curvature of an unknown surface includes positioning the spherometer on a surface between the surface and a depth measuring optical instrument. As the spherometer is frontally illuminated, the distance from the depth measuring instrument to the fiducial mark and the underlying surface are alternately measured and the difference in these measurements is used as the sagittal height to calculate a radius of curvature

  5. [Application of operant conditioning techniques to forensic toxicology: experimental studies on alcohol and abusable drugs].

    Science.gov (United States)

    Hishida, S

    1996-10-01

    This paper describes some experiments that apply the operant conditioning techniques to forensic toxicological research. These techniques may be useful in investigating the mechanisms of action, toxic symptoms, legal competence and drug metabolism associated with substance abuse such as abuse of alcohol, psychotropic drugs, narcotics, stimulants, and organic solvents. 1) Genetic research on alcohol preference in rats. We applied operant conditioning to investigate alcohol preference in rats and constructed an apparatus for the measurement of discriminated operate responses for water or alcohol reinforcement in rat. This apparatus is a modified Skinner box with a one-lever two-liquid system. Fixed ratio-10 (FR-10) schedules of reinforcement are used to increase the work of the rat before it obtains the reinforcement. The voluntary choice of water or 10% ethanol by the rat can be assessed quantitatively by measuring the lever-pushing responses. It is an extremely useful method for measuring the real alcohol preference of rats. A rat was kept in a Skinner box overnight. The numbers of responses and reinforcement for water and ethanol and the volumes of the two liquids consumed were recorded. The ratio of ethanol reinforcement was defined as the number of ethanol reinforcement to the total number of ethanol and water reinforcement. The ratio of ethanol intake was defined as the volume of ethanol consumed to the volume of water and ethanol consumed. Ethanol consumption per g body weight was calculated from the volume of ethanol consumed by the rat. We used this apparatus to investigate alcohol preference of more than 300 Wistar Albino Rats, and divided them into a high alcohol preference (HAP) group and a low alcohol preference (LAP) group. Inbreeding between littermates was conducted in each of the HAP and LAP groups. The liver tissue of each offspring was obtained and the cytosol fraction was collected and subjected to isoelectric focusing using polyacrylamide gel

  6. Optical fiber stripper positioning apparatus

    Science.gov (United States)

    Fyfe, Richard W.; Sanchez, Jr., Amadeo

    1990-01-01

    An optical fiber positioning apparatus for an optical fiber stripping device is disclosed which is capable of providing precise axial alignment between an optical fiber to be stripped of its outer jacket and the cutting blades of a stripping device. The apparatus includes a first bore having a width approximately equal to the diameter of an unstripped optical fiber and a counter bore axially aligned with the first bore and dimensioned to precisely receive a portion of the stripping device in axial alignment with notched cutting blades within the stripping device to thereby axially align the notched cutting blades of the stripping device with the axis of the optical fiber to permit the notched cutting blades to sever the jacket on the optical fiber without damaging the cladding on the optical fiber. In a preferred embodiment, the apparatus further includes a fiber stop which permits determination of the length of jacket to be removed from the optical fiber.

  7. The Conservation Ideological State Apparatus

    Directory of Open Access Journals (Sweden)

    Jared D Margulies

    2018-01-01

    Full Text Available This article considers Louis Althusser's theory of the ideological state apparatuses (ISAs for advancing political ecology scholarship on the functioning of the state in violent environments. I reflect on a series of events in which a state forest department in South India attempted to recast violent conflicts between themselves and local communities over access to natural resources and a protected area as a debate over human-wildlife conflicts. Through the example of conservation as ideology in Wayanad, Kerala, I show how the ISAs articulate the functioning of ideology within the state apparatuses in order for us to understand the larger mechanics of the state apparatus and the reproduction of the relations of production necessary for the reproduction of capitalism. Revisiting the ISAs as a theoretical framework for studies in political ecology and conservation is timely given the resurgence of militarised conservation tactics, the emancipatory aims of Althusser's theory, and political ecology's turn towards praxis.

  8. The Apparatus of Digital Archaeology

    Directory of Open Access Journals (Sweden)

    Jeremy Huggett

    2017-06-01

    Full Text Available Digital Archaeology is predicated upon an ever-changing set of apparatuses – technological, methodological, software, hardware, material, immaterial – which in their own ways and to varying degrees shape the nature of Digital Archaeology. Our attention, however, is perhaps inevitably more closely focused on research questions, choice of data, and the kinds of analyses and outputs. In the process we tend to overlook the effects the tools themselves have on the archaeology we do beyond the immediate consequences of the digital. This article introduces cognitive artefacts as a means of addressing the apparatus more directly within the context of the developing archaeological digital ecosystem. It argues that a critical appreciation of our computational cognitive artefacts is key to understanding their effects on both our own cognition and on the creation of archaeological knowledge. In the process, it defines a form of cognitive digital archaeology in terms of four distinct methods for extracting cognition from the digital apparatus layer by layer.

  9. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  10. Prehensile apparatus

    Science.gov (United States)

    Smith, C.M.

    1993-10-12

    The present invention relates to an apparatus for handling a workpiece comprising a vessel that is longitudinally extensible and pressurizable, and a nonextensible and laterally flexible member on the vessel. The member constrains one side of the vessel to be nonextensible, causing the vessel to bend in the direction of the nonextensible member when pressurized. 8 figures.

  11. Endovascular stentectomy using the snare over stent-retriever (SOS technique: An experimental feasibility study.

    Directory of Open Access Journals (Sweden)

    Tareq Meyer

    Full Text Available Feasibility of endovascular stentectomy using a snare over stent-retriever (SOS technique was evaluated in a silicon flow model and an in vivo swine model. In vitro, stentectomy of different intracranial stents using the SOS technique was feasible in 22 out of 24 (92% retrieval maneuvers. In vivo, stentectomy was successful in 10 out of 10 procedures (100%. In one case self-limiting vasospasm was observed angiographically as a technique related complication in the animal model. Endovascular stentectomy using the SOS technique is feasible in an experimental setting and may be transferred to a clinical scenario.

  12. A Simple Apparatus for Fast Ion Exchange Separations

    Energy Technology Data Exchange (ETDEWEB)

    Samsahl, K

    1964-09-15

    An apparatus suitable for very fast ion exchange group separations in radiochemistry has been elaborated. The apparatus which consists of a system of glass tubes with pistons driven by the same force, allows the exact adjustment of influent solutions to a long series of ion-exchange columns. The practical application of the apparatus to the simultaneous separation of six groups of trace elements in the neutron activation analysis of biological material is described.

  13. A Simple Apparatus for Fast Ion Exchange Separations

    International Nuclear Information System (INIS)

    Samsahl, K.

    1964-09-01

    An apparatus suitable for very fast ion exchange group separations in radiochemistry has been elaborated. The apparatus which consists of a system of glass tubes with pistons driven by the same force, allows the exact adjustment of influent solutions to a long series of ion-exchange columns. The practical application of the apparatus to the simultaneous separation of six groups of trace elements in the neutron activation analysis of biological material is described

  14. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data ...

  15. Apparatus for blending small particles

    International Nuclear Information System (INIS)

    Bradley, R.A.; Reese, C.R.; Sease, J.D.

    1975-01-01

    An apparatus is described for blending small particles and uniformly loading the blended particles in a receptacle. Measured volumes of various particles are simultaneously fed into a funnel to accomplish radial blending and then directed onto the apex of a conical splitter which collects the blended particles in a multiplicity of equal subvolumes. Thereafter the apparatus sequentially discharges the subvolumes for loading in a receptacle. A system for blending nuclear fuel particles and loading them into fuel rod molds is described in a preferred embodiment

  16. On the measurement of a weak classical force coupled to a harmonic oscillator: experimental progress

    International Nuclear Information System (INIS)

    Bocko, M.F.; Onofrio, R.

    1996-01-01

    Several high-precision physics experiments are approaching a level of sensitivity at which the intrinsic quantum nature of the experimental apparatus is the dominant source of fluctuations limiting the sensitivity of the measurements. This quantum limit is embodied by the Heisenberg uncertainty principle, which prohibits arbitrarily precise simultaneous measurements of two conjugate observables of a system but allows one-time measurements of a single observable with any precision. The dynamical evolution of a system immediately following a measurement limits the class of observables that may be measured repeatedly with arbitrary precision, with the influence of the measurement apparatus on the system being confined strictly to the conjugate observables. Observables having this feature, and the corresponding measurements performed on them, have been named quantum nondemolition or back-action evasion observables. In a previous review (Caves et al., 1980, Rev. Mod. Phys. 52, 341) a quantum-mechanical analysis of quantum nondemolition measurements of a harmonic oscillator was presented. The present review summarizes the experimental progress on quantum nondemolition measurements and the classical models developed to describe and guide the development of practical implementations of quantum nondemolition measurements. The relationship between the classical and quantum theoretical models is also reviewed. The concept of quantum nondemolition and back-action evasion measurements originated in the context of measurements on a macroscopic mechanical harmonic oscillator, though these techniques may be useful in other experimental contexts as well, as is discussed in the last part of this review. copyright 1996 The American Physical Society

  17. Method of magnetic separation and apparatus therefore

    Science.gov (United States)

    Oder, Robin R. (Inventor)

    1991-01-01

    An apparatus for magnetically separating and collecting particulate matter fractions of a raw sample according to relative magnetic susceptibilities of each fraction so collected is disclosed. The separation apparatus includes a splitter which is used in conjunction with a magnetic separator for achieving the desired fractionation.

  18. Application of Modern Experimental Technique to Solve Morphological Complexity in Plants Taxonomy

    Directory of Open Access Journals (Sweden)

    SURANTO

    2000-07-01

    Full Text Available Modern taxonomy has two approaches, i.e. classical and experimental taxonomy. Classical taxonomy uses morphological characters, while experimental taxonomy uses broader methods including chemistry, physics and mathematics, in the form of laboratory data that are revealed together with the progress of optical technique (microscope, chemistry methods (chromatography, electrophoresis, etc. Modern taxonomy tends to use series of interrelated data. More data used would result in more validity and give better clarification of taxonomic status. A lot of modern taxonomic data such as palynology, cytotaxonomy (cytology, chemical constituent (chemotaxonomy, isozyme and DNA sequencing were used recently.

  19. Assembly and handling apparatus for the EBFA Marx generator

    International Nuclear Information System (INIS)

    Staller, G.E.; Hiett, G.E.; Hamilton, I.D.; Aker, M.F.; Daniels, G.A.

    1979-05-01

    Marx generators, a major slow-pulsed power component in Sandia Laboratories' Electron Beam Fusion Accelerator (EBFA), were assembled at a remote facility modified to utilize an assembly-line technique. Due to the size and weight of the various components, as well as the final Marx generator assembly, special handling apparatus was designed. Time and manpower constraints required that this assembly be done in parallel with the construction of the Electron Beam Fusion Facility (EBFF). The completed Marx generators were temporarily stored and then moved from the assembly building to the EBFF using special transportation racks designed specifically for this purpose

  20. Experimental program for development and evaluation of nondestructive assay techniques for plutonium holdup

    International Nuclear Information System (INIS)

    Brumbach, S.B.

    1977-05-01

    An outline is presented for an experimental program to develop and evaluate nondestructive assay techniques applicable to holdup measurement in plutonium-containing fuel fabrication facilities. The current state-of-the-art in holdup measurements is reviewed. Various aspects of the fuel fabrication process and the fabrication facility are considered for their potential impact on holdup measurements. The measurement techniques considered are those using gamma-ray counting, neutron counting, and temperature measurement. The advantages and disadvantages of each technique are discussed. Potential difficulties in applying the techniques to holdup measurement are identified. Experiments are proposed to determine the effects of such problems as variation in sample thickness, in sample distribution, and in background radiation. These experiments are also directed toward identification of techniques most appropriate to various applications. Also proposed are experiments to quantify the uncertainties expected for each measurement

  1. Superconducting magnetic shielding apparatus and method

    Science.gov (United States)

    Clem, John R.; Clem, John R.

    1983-01-01

    Disclosed is a method and apparatus for providing magnetic shielding around a working volume. The apparatus includes a hollow elongated superconducting shell or cylinder having an elongated low magnetic pinning central portion, and two high magnetic pinning end regions. Transition portions of varying magnetic pinning properties are interposed between the central and end portions. The apparatus further includes a solenoid substantially coextensive with and overlying the superconducting cylinder, so as to be magnetically coupled therewith. The method includes the steps passing a longitudinally directed current through the superconducting cylinder so as to depin magnetic reservoirs trapped in the cylinder. Next, a circumferentially directed current is passed through the cylinder, while a longitudinally directed current is maintained. Depinned magnetic reservoirs are moved to the end portions of the cylinder, where they are trapped.

  2. Superconducting magnetic shielding apparatus and method

    Science.gov (United States)

    Clem, J.R.

    1982-07-09

    Disclosed is a method and apparatus for providing magnetic shielding around a working volume. The apparatus includes a hollow elongated superconducting shell or cylinder having an elongated low magnetic pinning central portion, and two high magnetic pinning end regions. Transition portions of varying magnetic pinning properties are interposed between the central and end portions. The apparatus further includes a solenoid substantially coextensive with and overlying the superconducting cylinder, so as to be magnetically coupled therewith. The method includes the steps passing a longitudinally directed current through the superconducting cylinder so as to depin magnetic reservoirs trapped in the cylinder. Next, a circumferentially directed current is passed through the cylinder, while a longitudinally directed current is maintained. Depinned magnetic reservoirs are moved to the end portions of the cylinder, where they are trapped.

  3. MUP, CEC-DES, STRADE. Codes for uncertainty propagation, experimental design and stratified random sampling techniques

    International Nuclear Information System (INIS)

    Amendola, A.; Astolfi, M.; Lisanti, B.

    1983-01-01

    The report describes the how-to-use of the codes: MUP (Monte Carlo Uncertainty Propagation) for uncertainty analysis by Monte Carlo simulation, including correlation analysis, extreme value identification and study of selected ranges of the variable space; CEC-DES (Central Composite Design) for building experimental matrices according to the requirements of Central Composite and Factorial Experimental Designs; and, STRADE (Stratified Random Design) for experimental designs based on the Latin Hypercube Sampling Techniques. Application fields, of the codes are probabilistic risk assessment, experimental design, sensitivity analysis and system identification problems

  4. Radiation therapy apparatus having retractable beam stopper

    International Nuclear Information System (INIS)

    Coad, G.L.

    1983-01-01

    This invention relates to a radiation therapy apparatus which utilized a linear translation mechanism for positioning a beam stopper. An apparatus is described wherein the beam stopper is pivotally attached to the therapy machine with an associated drive motor in such a way that the beam stopper retracts linearly

  5. Apparatus for separating solids from a liquid

    NARCIS (Netherlands)

    Rem, P.C.; Berkhout, S.P.M.

    2007-01-01

    The invention relates to an apparatus and a method for separating a material stream consisting of several materials. The materials to be separated have different densities or density ranges, so that the material of the highest density can be discharged through a screen of the apparatus, while the

  6. Development and application of PIE apparatuses for high-burnup LWR fuels

    International Nuclear Information System (INIS)

    Harada, Katsuya; Mita, Naoaki; Nishino, Yasuharu; Amano, Hidetoshi

    1999-01-01

    The Reactor Fuel Examination Facility (RFEF) is developing the following post irradiation examination apparatuses: Ion Microprobe mass analyzer (IMA), Pellet Thermal Capacity measuring apparatus (PTC), Micro Density Measuring apparatus MDM, Shield-type Field Emission Scanning Electron Microscope (FE-SEM). The present paper mainly describes several technical topics of these apparatuses. (author)

  7. Apparatus for controlling fluidized beds

    Science.gov (United States)

    Rehmat, A.G.; Patel, J.G.

    1987-05-12

    An apparatus and process are disclosed for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance. 2 figs.

  8. Apparatus and method for radiation processing of materials

    International Nuclear Information System (INIS)

    Neuberg, W.B.; Luniewski, R.

    1983-01-01

    A method and apparatus for radiation degradation processing of polytetrafluoroethylene makes use of a simultaneous irradiation, agitation and cooling. The apparatus is designed to make efficent use of radiation in the processing. (author)

  9. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  10. Ion implantation apparatus

    International Nuclear Information System (INIS)

    Forneris, J.L.; Hicks, W.W.; Keller, J.H.; McKenna, C.M.; Siermarco, J.A.; Mueller, W.F.

    1981-01-01

    The invention relates to ion bombardment or implantation apparatus. It comprises an apparatus for bombarding a target with a beam of ions, including an arrangement for measuring the ion beam current and controlling the surface potential of the target. This comprises a Faraday cage formed, at least in part, by the target and by walls adjacent to, and electrically insulated from, the target and surrounding the beam. There is at least one electron source for supplying electrons to the interior of the Faraday cage and means within the cage for blocking direct rectilinear radiation from the source to the target. The target current is measured and combined with the wall currents to provide a measurement of the ion beam current. The quantity of electrons supplied to the interior of the cage can be varied to control the target current and thereby the target surface potential. (U.K.)

  11. Report upon inquiry into radiation apparatus

    International Nuclear Information System (INIS)

    1984-10-01

    In this report the committee has provided its assessment of the need and justification for the law to provide for the control of the provision of radiation apparatus, the planning needs for the provision of diagnostic and therapeutic facilities, the location of such facilities, the appropriateness or otherwise of existing legislation, the necessity for any further legislative needs and the criteria governing the provision of such radiation apparatus

  12. Novel Experimental Techniques to Investigate Wellbore Damage Mechanisms

    Science.gov (United States)

    Choens, R. C., II; Ingraham, M. D.; Lee, M.; Dewers, T. A.

    2017-12-01

    A new experimental technique with unique geometry is presented investigating deformation of simulated boreholes using standard axisymmetric triaxial deformation equipment. The Sandia WEllbore SImulation, SWESI, geometry, uses right cylinders of rock 50mm in diameter and 75mm in length. A 11.3mm hole is drilled perpendicular to the axis of the cylinder in the center of the sample to simulate a borehole. The hole is covered with a solid metal cover, and sealed with polyurethane. The metal cover can be machined with a high-pressure port to introduce different fluid chemistries into the borehole at controlled pressures. Samples are deformed in a standard load frame under confinement, allowing for a broad range of possible stresses, load paths, and temperatures. Experiments in this study are loaded to the desired confining pressure, then deformed at a constant axial strain rate or 10-5 sec-1. Two different suites of experiments are conducted in this study on sedimentary and crystalline rock types. The first series of experiments are conducted on Mancos Shale, a finely laminated transversely isotropic rock. Samples are cored at three different orientations to the laminations. A second series of experiments is conducted on Sierra White granite with different fluid chemistries inside the borehole. Numerical modelling and experimental observations including CT-microtomography demonstrate that stresses are concentrated around the simulated wellbore and recreate wellbore deformation mechanisms. Borehole strength and damage development is dependent on anisotropy orientation and fluid chemistry. Observed failure geometries, particularly for Mancos shale, can be highly asymmetric. These results demonstrate uncertainties in in situ stresses measurements using commonly-applied borehole breakout techniques in complicated borehole physico-chemical environments. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering

  13. Apparatus and method for gelling liquefied gasses

    Science.gov (United States)

    Elliott, Adam (Inventor); DiSalvo, Roberto (Inventor); Shepherd, Phillip (Inventor); Kosier, Ryan (Inventor)

    2011-01-01

    A method and apparatus for gelling liquid propane and other liquefied gasses includes a temperature controlled churn mixer, vacuum pump, liquefied gas transfer tank, and means for measuring amount of material entering the mixer. The apparatus and method are particularly useful for the production of high quality rocket fuels and propellants.

  14. Apparatus Named after Our Academic Ancestors, III

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2014-01-01

    My academic ancestors in physics have called on me once more to tell you about the apparatus that they devised, and that many of you have used in your demonstrations and labs. This article is about apparatus named after François Arago, Heinrich Helmholtz, Leon Foucault, and James Watt.

  15. Influence of Temperature and Catalyst on the Decomposition of Potassium Chlorate in a Simple DTA-Apparatus.

    Science.gov (United States)

    Wiederholt, Erwin

    1983-01-01

    DTA is a technique in which the temperature difference between sample/reference is measured as a function of temperature, while both are subject to a controlled temperature program. Use of a simple DTA-apparatus in demonstrating catalytic effects of manganese dioxide and aluminum oxide on decomposition temperature of potassium chlorate is…

  16. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-01-01

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water

  17. Experimental Analysis of Temperature Differences During Implant Site Preparation: Continuous Drilling Technique Versus Intermittent Drilling Technique.

    Science.gov (United States)

    Di Fiore, Adolfo; Sivolella, Stefano; Stocco, Elena; Favero, Vittorio; Stellini, Edoardo

    2018-02-01

    Implant site preparation through drilling procedures may cause bone thermonecrosis. The aim of this in vitro study was to evaluate, using a thermal probe, overheating at implant sites during osteotomies through 2 different drilling methods (continuous drilling technique versus intermittent drilling technique) using irrigation at different temperatures. Five implant sites 13 mm in length were performed on 16 blocks (fresh bovine ribs), for a total of 80 implant sites. The PT-100 thermal probe was positioned 5 mm from each site. Two physiological refrigerant solutions were used: one at 23.7°C and one at 6.0°C. Four experimental groups were considered: group A (continuous drilling with physiological solution at 23.7°C), group B (intermittent drilling with physiological solution at 23.7°C), group C (continuous drilling with physiological solution at 6.0°C), and group D (intermittent drilling with physiological solution at 6.0°C). The Wilcoxon rank-sum test (2-tailed) was used to compare groups. While there was no difference between group A and group B (W = 86; P = .45), statistically significant differences were observed between experimental groups A and C (W = 0; P =.0001), B and D (W = 45; P =.0005), and C and D (W = 41; P = .003). Implant site preparation did not affect the overheating of the bone. Statistically significant differences were found with the refrigerant solutions. Using both irrigating solutions, bone temperature did not exceed 47°C.

  18. Metering apparatus and tariffs for electricity supply

    International Nuclear Information System (INIS)

    1990-01-01

    Conference papers presented cover system economies and tariff structure with papers on pricing of electricity and new metering technologies. Other topics reviewed include metering apparatus design, electronic metering apparatus and solid phase metering technology. Meter data retrieval, bulk supply metering, test equipment and maintenance, and legal requirements and standards are discussed. (author)

  19. Apparatus and method for comparing corresponding acoustic resonances in liquids

    Science.gov (United States)

    Sinha, Dipen N.

    1999-01-01

    Apparatus and method for comparing corresponding acoustic resonances in liquids. The present invention permits the measurement of certain characteristics of liquids which affect the speed of sound therein. For example, a direct correlation between the octane rating of gasoline and the speed of sound in a gasoline sample has been experimentally observed. Therefore, changes in the speed of sound therein can be utilized as a sensitive parameter for determining changes in composition of a liquid sample. The present apparatus establishes interference patterns inside of a liquid without requiring the use of very thin, rigorously parallel ceramic discs, but rather uses readily available piezoelectric transducers attached to the outside surface of the usual container for the liquid and located on the same side thereof in the vicinity of one another. That is, various receptacle geometries may be employed, and the driving and receiving transducers may be located on the same side of the receptacle. The cell may also be constructed of any material that is inert to the liquid under investigation. A single-transducer embodiment, where the same transducer provides the excitation to the sample container and receives signals impressed therein, is also described.

  20. Dispensing apparatus for use in a cued food delivery task.

    Science.gov (United States)

    Deweese, Menton M; Claiborne, Kimberly N; Ng, Jennifer; Dirba, Danika D; Stewart, Hannah L; Schembre, Susan M; Versace, Francesco

    2015-01-01

    Neurobiological models of obesity postulate that obese individuals have difficulty regulating food intake partly because they attribute excessive salience to stimuli signaling food availability. Typically, human studies that investigate the relationship between brain responses to food-related stimuli and obesity present food cues without subsequent delivery of food. However, in order to identify the brain correlates of cue reactivity, we must record brain responses to food-related cues signaling food availability. Therefore, we have developed a dispensing apparatus for use in a cued-food delivery task in which event-related potentials (ERPs) to food-related images predicting food delivery and images not predicting food delivery can be recorded. Here, we describe a method where:•The experimental apparatus dispenses an edible item (i.e., a chocolate candy) which may or may not be eaten, or a non-edible control item (e.g., a plastic bead).•Deposit boxes are available to store uneaten candies and the non-edible control items.•The dispensing mechanism is capable of recording the exact timestamp when each delivery event occurs (e.g., release from the dispenser, arrival in the receptacle, storage in the deposit box).

  1. Po2 temperature blood factor for blood gas apparatus.

    Science.gov (United States)

    Teisseire, B P; Hérigault, R A; Teisseire, L J; Laurent, D N

    1984-01-01

    PO2 temperature formulae supplied by manufacturers on automatic blood gas apparatus, PO2 corr. = PO2 37 degrees C X 10F X delta T were studied and compared to the experimental determination of the delta log PO2/delta T ratio (Hérigault et al. [10]). Acid-base status at 37 degrees C appeared to have a measurable influence on the PO2 temperature factor; alkalosis increased the delta log PO2/delta T ratio, and the contrary was found for acidosis in comparison with normal acid-base status at 37 degrees C. For the same PO2, measured at 37 degrees C, all the proposed formulae of commercial blood gas automatic apparatus did not give the same temperature corrected PO2. The observed difference between the corrected PO2 may be important and greater than the precision of the initial measurement. To correct the measured PO2 for temperature, a relationship between delta log PO2/delta T and PO2 is proposed, between PO2 zero and PO2 180 mmHg, which takes into account measured pH and PO2 values at 37 degrees C:delta log PO2/delta T = [(-0.35 pH + 0.658) X 10(-4) X PO2] + 0.035.

  2. Apparatus for carbonization of bituminous materials

    Energy Technology Data Exchange (ETDEWEB)

    Krupa, G

    1924-08-25

    Apparatus is described for carbonization of bituminous fuels and bituminous shale, in which the material to be carbonized slips continuously over sloping surfaces of a retort arranged in a zigzag and thereby it is exposed to a continuously increasing heating. The apparatus is characterized by the sloping surface being of a boxlike solid hearth with internal heating through which every hearth can be heated directly to a determined constant degree of heat.

  3. Centrifuge apparatus

    Science.gov (United States)

    Sartory, Walter K.; Eveleigh, John W.

    1976-01-01

    A method and apparatus for operating a continuous flow blood separation centrifuge are provided. The hematocrit of the entrant whole blood is continuously maintained at an optimum constant value by the addition of plasma to the entrant blood. The hematocrit of the separated red cells is monitored to indicate the degree of separation taking place, thereby providing a basis for regulating the flow through the centrifuge.

  4. Apparatus for making an X-ray photograph of an object

    International Nuclear Information System (INIS)

    Yang, K.-H.; Gruenke, L.A.

    1979-01-01

    A method and apparatus are described for ion-valve radiography allowing a multiplicity of copies to be made responsive to a single radiographic exposure. Radiation, differentially-absorbed by passage through an object to be studied, enters an exposure chamber having a foraminate film or mesh structure surrounded by a high pressure gas or radio-conductive liquid of a type which converts the impingent radiation into electrostatic charge. The chamber is bounded by a pair of electrodes establishing electric fields therein to cause a charge image of the object to form upon an insulating layer contained upon the mesh structure. After exposure, the charge-image-bearing member is moved to a printing chamber and a charge image is deposited upon an insulative material sheet by ion flow techniques, for subsequent development by xerographic techniques. (Auth.)

  5. Pin-on-disk apparatus for tribological studies of polymeric materials

    DEFF Research Database (Denmark)

    Ølholm Larsen, Thomas; Løgstrup Andersen, Tom; Thorning, Bent

    2009-01-01

    polymeric materials under dry-sliding conditions. The different main parts of the apparatus are described in a way which partly explains the choice of construction and partly makes it possible to produce a similar apparatus. Furthermore, a limited amount of tribological data is presented mainly to exemplify......The purpose of this paper is to describe the construction of a custom-built pin-on-disk (POD) apparatus based on a simple design and on important guidelines. The POD apparatus is built as a part of the main author's PhD project. The apparatus is built at a low cost and is suited for testing...... weave. The data presented in this paper are limited since the main objective is to describe the construction of a POD apparatus. The paper is intended to be a source of inspiration for industrial or academic laboratories who want to establish their own tailor-suited tribological test-equipment, instead...

  6. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-02-14

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water or other cleaning liquids in the whole cleaning process, which makes them prominent well suited in for water-deficit environments such as deserts. In one embodiment, the solar panel cleaning apparatus comprises one or more rotatable brushes each having a rotational axis and a drive configured to move each of the one or more rotatable brushes in a direction that is not perpendicular to the rotational axis. The solar panel cleaning apparatus is may be configured such that the angle of the rotational axis of at least one of the one or more rotatable brushes is adjustable relative to the direction of travel.

  7. Thermal Acoustic Fatigue Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Acoustic Fatigue Apparatus (TAFA) is a progressive wave tube test facility that is used to test structures for dynamic response and sonic fatigue due to...

  8. Fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for loading a predetermined amount of nuclear fuel pellets into nuclear fuel elements and particularly for the automatic loading of fuel pellets from within a sealed compartment. (author)

  9. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  10. Fuel exchanging apparatus

    International Nuclear Information System (INIS)

    Imada, Takahiko; Sato, Hideo.

    1975-01-01

    Object: To provide a centripetal device, which has an initial spring force greater than a frictional force in an oscillating direction of a telescope mast, on a mast fixing device mounted on a body of fuel exchanging apparatus so that the telescope mast may be secured quickly returning to a predetermined initial position. Structure: When the body of fuel exchanging apparatus is stopped at a predetermined position, a tension spring, which has an initial spring force greater than a frictional force in an oscillating direction of the telescope mast, causes a lug to be forced by means of a push rod to position a sliding base plate to its original position. At the same time, a device of similar structure causes an operating arm to be positioned to the original position, and a lock pin urged by a cylinder is inserted into a through hole in the sliding base plate and operating arm so that the telescope mast may be fixed and retained. (Hanada, M.)

  11. Model of Coupled Drives Apparatus – Static and Dynamic Characteristics

    Directory of Open Access Journals (Sweden)

    Chalupa Petr

    2016-01-01

    Full Text Available The paper presents an initial part of a modelling the Coupled Drives Apparatus CE108 developed by TecQuipment Ltd. The final model should be used in the process of control design for the apparatus. The model derived by the developers of the apparatus using first-principle modelling is used as a starting point for comparison of its properties with measured characteristics. The static and dynamic characteristics of the real-time apparatus are presented and discussed. Special attention is paid to principal differences between the model and the real-time apparatus. Real-time measurements are obtained using MATLAB / Simulink environment in connection with a Real-time Toolbox. Evaluation of the experiments is also performed in the MATLAB environment

  12. Device for discharging drain in a control rod driving apparatus

    International Nuclear Information System (INIS)

    Ikeda, Tadasu; Ikuta, Takuzo; Yoshida, Tomiji; Tsukahara, Katsumi.

    1975-01-01

    Object: To efficiently and safely collect and discharge drain by a simple construction in which a drain cover and a drain tank in a control rod driving apparatus are integrally formed, and an overhauling wrench of said apparatus and a drain hose are mounted on the drain tank. Structure: When a mounting bolt is untightened by a torque wrench so as to be removed from a flange surface of the control rod driving apparatus in a nuclear reactor, axial movement of said apparatus is absorbed by a spring so that drain containing a radioactive material is discharged into a drain tank through the flange surface of said apparatus and is then guided into a collecting tank through a drain hose. (Kamimura, M.)

  13. Storming a Citadel: Mathematical Theory and Experimental Practice

    Science.gov (United States)

    Sichau, Christian

    2006-09-01

    Based upon a comparison of the viscosity experiments of James Clerk Maxwell (1831 1879) and Oskar Emil Meyer (1834 1909) in the 1860s, I argue that mathematical theory plays a significant role in both aspects of experimental practice, the design and construction of an experimental apparatus and the transformation of the observed experimental data into the value of a physical quantity. I argue further that Maxwell’s and Meyer’s evaluation of each other’s theoretical and experimental work depended significantly on the mathematical tools they employed in their theories.

  14. Method and apparatus for dismantling mechanical anchors

    Energy Technology Data Exchange (ETDEWEB)

    Dubovskiy, Yu P; Chendev, F S; Gritsayuk, B I; Gubin, N I; Osipov, S P

    1982-01-01

    This apparatus is designed to reduce the amount of labor required to dismantle mechanical anchors while at the same time lowering expenditures for lumber. Longwall beams and timber skips are used to support the cap and any fractured rock faces. The apparatus itself has grooves, vertical guides, and a drive system to position the longwall beams.

  15. Apparatus For Eddy-Current Inspection Of Bolts

    Science.gov (United States)

    Amos, Jay M.

    1994-01-01

    Eddy-current apparatus for inspection of bolts, studs, and other threaded fasteners detects flaws in threads, shanks, and head fillets. With help of apparatus, technician quickly inspects fasteners of various dimensions. Accommodates fasteners with diameters from 0.190 in. to 1 in. and with lengths up to 5 in. Basic design modified to accommodate fasteners of other sizes.

  16. 3-D thermo-mechanical laboratory modeling of plate-tectonics: modeling scheme, technique and first experiments

    Directory of Open Access Journals (Sweden)

    D. Boutelier

    2011-05-01

    Full Text Available We present an experimental apparatus for 3-D thermo-mechanical analogue modeling of plate tectonic processes such as oceanic and continental subductions, arc-continent or continental collisions. The model lithosphere, made of temperature-sensitive elasto-plastic analogue materials with strain softening, is submitted to a constant temperature gradient causing a strength reduction with depth in each layer. The surface temperature is imposed using infrared emitters, which allows maintaining an unobstructed view of the model surface and the use of a high resolution optical strain monitoring technique (Particle Imaging Velocimetry. Subduction experiments illustrate how the stress conditions on the interplate zone can be estimated using a force sensor attached to the back of the upper plate and adjusted via the density and strength of the subducting lithosphere or the lubrication of the plate boundary. The first experimental results reveal the potential of the experimental set-up to investigate the three-dimensional solid-mechanics interactions of lithospheric plates in multiple natural situations.

  17. Applicability of two automated disintegration apparatuses for rapidly disintegrating (mini)tablets.

    Science.gov (United States)

    Sieber, Daniel; Lazzari, Alessia; Quodbach, Julian; Pein, Miriam

    2017-03-01

    Orally disintegrating (mini)tablets (OD(M)Ts) are of interest in the field of pharmaceutics. Their orodispersible character is defined by the disintegration time, which is measured with a basket apparatus according to the European Pharmacopoeia. This method, however, lacks applicability for ODTs and especially ODMTs. New disintegration apparatuses have been described in literature, but a qualification to assess the applicability has not been described. A qualification procedure for two automated disintegration apparatuses, OD-mate and Hermes apparatus, is introduced. Aspects of the operational qualification as well as precision and accuracy regarding a performance qualification were evaluated for both apparatuses analog to the ICH guideline Q2. While the OQ study is performed separately for each apparatus, accuracy and precision were performed following the same protocol for both testers. Small RSDs (16.9% OD-mate; 15.2% Hermes compared to 32.3% for the pharmacopeial method) were found despite very fast disintegration times (1.5 s for both apparatuses). By comparing these RSDs to practical examples, the authors propose threshold values for repeatability depending on the mean disintegration time. Obtained results from the qualification were used to assess the applicability of both apparatuses.

  18. A prototype splitter apparatus for dividing large catches of small fish

    Science.gov (United States)

    Stapanian, Martin A.; Edwards, William H.

    2012-01-01

    Due to financial and time constraints, it is often necessary in fisheries studies to divide large samples of fish and estimate total catch from the subsample. The subsampling procedure may involve potential human biases or may be difficult to perform in rough conditions. We present a prototype gravity-fed splitter apparatus for dividing large samples of small fish (30–100 mm TL). The apparatus features a tapered hopper with a sliding and removable shutter. The apparatus provides a comparatively stable platform for objectively obtaining subsamples, and it can be modified to accommodate different sizes of fish and different sample volumes. The apparatus is easy to build, inexpensive, and convenient to use in the field. To illustrate the performance of the apparatus, we divided three samples (total N = 2,000 fish) composed of four fish species. Our results indicated no significant bias in estimating either the number or proportion of each species from the subsample. Use of this apparatus or a similar apparatus can help to standardize subsampling procedures in large surveys of fish. The apparatus could be used for other applications that require dividing a large amount of material into one or more smaller subsamples.

  19. Experimental Studies of Carbon Nanotube Materials for Space Radiators

    Science.gov (United States)

    SanSoucie, MIchael P.; Rogers, Jan R.; Craven, Paul D.; Hyers, Robert W.

    2012-01-01

    Game ]changing propulsion systems are often enabled by novel designs using advanced materials. Radiator performance dictates power output for nuclear electric propulsion (NEP) systems. Carbon nanotubes (CNT) and carbon fiber materials have the potential to offer significant improvements in thermal conductivity and mass properties. A test apparatus was developed to test advanced radiator designs. This test apparatus uses a resistance heater inside a graphite tube. Metallic tubes can be slipped over the graphite tube to simulate a heat pipe. Several sub ]scale test articles were fabricated using CNT cloth and pitch ]based carbon fibers, which were bonded to a metallic tube using an active braze material. The test articles were heated up to 600 C and an infrared (IR) camera captured the results. The test apparatus and experimental results are presented here.

  20. Using tracer methods and experimental design approach for examination of hydrodynamic conditions in membrane separation modules

    Energy Technology Data Exchange (ETDEWEB)

    Miskiewicz, Agnieszka, E-mail: a.miskiewicz@ichtj.waw.pl [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland); Zakrzewska-Trznadel, Grazyna; Dobrowolski, Andrzej; Jaworska-Sobczak, Agnieszka [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland)

    2012-05-15

    The possibility of application of fluorescein and radioactive 99mTc as tracers for determination of residence time distribution of liquid phase and for diagnosing hydrodynamic conditions in apparatuses for membrane separation was studied. Two different ultrafiltration systems with diverse arrangement of liquid flow: the apparatus with helical flow generated by the movable element (inner cylinder) and the tubular module with cross flow filtration, were tested by the RTD technique. The tracer studies were supplemented with modelling. The optimal conditions enabling to handle the plug flow-like structure in the helical apparatus were determined. The minimum of dimensionless variance (vard) was obtained at P=0.765 bar, Q{sub R}=121.88 l/h and {Omega}=2887.5 rpm. In spite of higher linear velocities attained in the tubular cross-flow module, the flow structure in the helical apparatus was more similar to the ideal plug flow pattern that was demonstrated by higher Peclet numbers and lower values of the dimensionless variance. Application of movable part and Couette-Taylor flow in the membrane apparatus may balance the advantages coming from high flow rates applied in cross-flow filtration systems minimising formation of the deposit on the membrane surface and reducing membrane fouling. - Highlights: Black-Right-Pointing-Pointer Application of RTD method with modelling for testing the membrane modules. Black-Right-Pointing-Pointer The use of generator isotope, as convenient tracer for the membrane modules studies. Black-Right-Pointing-Pointer Application of RSM with experimental design for testing interactions between parameters. Black-Right-Pointing-Pointer Assessment of the hydrodynamic conditions in two arrangements of the membrane modules. Black-Right-Pointing-Pointer Demonstration of the advantage of dynamic filtration over the cross-flow arrangement.

  1. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  2. Study of a micro-sublimation apparatus with removal of the vapours by pumping; application to the analysis of fluorinated products (1963)

    International Nuclear Information System (INIS)

    Delvalle, P.

    1963-01-01

    Micro-sublimation analysis presents definite advantages both from the qualitative and quantitative points of view. An automatic micro-sublimation analysis apparatus has been developed for the analysis of fluorinated products (ClF 3 , HF, UF 6 , etc.) but this is only one particular application of a method which has a far wider field of possible applications. We give first the most favorable conditions for the operation of such an apparatus. These conditions are the use of a detector which is linear and independent of the nature of the gas, the flow of the sublimed vapours in the conditions of molecular flow, and finally a reproducible and linear re-heating of the separating trap. The apparatus thus built has the advantage of yielding any analysis without prior calibration. It also makes possible the easy identification of an unknown product by the determination of its vapour pressure curve and its molecular weight. The analysis of fluorinated products with this apparatus has shown that the experimental results agree well with what is expected. (author) [fr

  3. Polymethylmethacrylate combustion in a narrow channel apparatus simulating a microgravity environment

    Science.gov (United States)

    Bornand, Garrett Randall

    compared to results found by Michigan State University's NCA. Flame spread results from the SDSU NCA compare closely to that of the other experimental techniques. Additionally, an infrared camera and species concentration sensors were added to the SDSU NCA and initial results are provided. Fire Dynamics Simulator (FDS) was used to model the combustion of PMMA within the SDSU NCA. Both thin and thick fuel beds were simulated and the numerical results were compared to experimental data. The simulation was then used to determine various results that cannot easily be found with experimentation, including how effectively the NCA simulates microgravity under certain environmental conditions, gas and fuel bed temperatures, heat fluxes, species concentrations, pyrolysis rate, and other various data. The simulation was found to give reasonable results and overall flame spread trends, but could be improved upon with further detailed kinetic parameter studies.

  4. utilization of adsorption and/or liquid membranes techniques in treatment of some hazardous substances

    International Nuclear Information System (INIS)

    Hussin, L.M.S.

    2011-01-01

    environmental pollution, as a consequence of the industrialization process, is one of the major problems that has to be solved and controlled. The most important treatment processes for metals and dyes contaminated waste streams include chemical precipitation, membrane, filtration, ion exchange, carbon adsorption and coprecipitation/adsorption. However, all these techniques have their inherent advantages and limitations in applications. These processes usually need expensive facility and high maintenance cost. Therefore, there is a need for more economical alternative technologies for the treatment of metals and dyes contaminated waste streams. The aim of present work is to study the treatment of some hazardous substances such as heavy metals e.g. ( lead, cobalt and strontium) and dyes e.g. ( acid red 73, and acid blue 74 ) using either adsorption or liquid emulsion membrane techniques. The experimental part deals with the application of adsorption and liquid emulsion membrane techniques for removal of some hazardous substances such as metal ions ( lead, cobalt and strontium) and dyes (acid red 73 and acid blue 74). All the apparatus and techniques employed were described.

  5. ESR dating: is it still an 'experimental' technique?

    International Nuclear Information System (INIS)

    Skinner, A.R.

    2000-01-01

    Nearly 25 years ago, Motoji Ikeya demonstrated the potential of ESR dating. From a single substance (stalagmitic carbonate) and a single site (Akiyoshi Cavern), the field has grown to include materials from all over the world and time periods from a few thousand years ago to several million years ago. A vigorous program of instrumentation development has increased the precision of measurements as well as opening up new ways of collecting and interpreting spectra. Yet there are still references to ESR dating as an 'experimental' technique, one which cannot be trusted to produce dates that are accurate or precise. This paper discusses areas for which this is true and suggests what should be done to convince skeptics. Other areas for which the evidence suggests that ESR is at least as reliable as 'standard' methods will also be covered

  6. CASTING APPARATUS

    Science.gov (United States)

    Gray, C.F.; Thompson, R.H.

    1958-09-23

    An apparatus is described for casting small quantities of uranlum. It consists of a crucible having a hole in the bottom with a mold positioned below. A vertical rcd passes through the hole in the crucible and has at its upper end a piercing head adapted to break the oxide skin encasing a molten uranium body. An air tight cylinder surrounds the crucible and mold, and is arranged to be evacuated.

  7. Effect of Professionalism, Competence, Knowledge of Financial Management, and Intensity Guidance Apparatus Inspectorate for Quality of Financial Statements (Study on Inspectorate Regencies/Cities in Aceh

    Directory of Open Access Journals (Sweden)

    Darwanis Darwanis

    2016-04-01

    Full Text Available This research aims to: 1. Examine the influence of professionalism, competence, knowledge of financial management and intensity guidance apparatus Inspectorate together to the quality of the financial statements of Regions; 2. Examine the effect of professionalism partially on the quality of the financial statements of Regions; 3. Test the effect of partial competencies to the quality of the financial statements of Regions; 4. Examine the effect of knowledge of financial management partially on the quality of the financial statements of Regions; 5. The authorities test the effects of intensity guidance apparatus partially on the quality of the financial statements of Regions. The object of this research is the Government Internal Supervisory Apparatus (APIP working in the Inspectorate districts/cities in Aceh amounted to 23 people who perform inspection tasks.  The source of data in this study uses primary data which is the result of the acquisition of questionnaires from survey respondent, while research data collection techniques are done with documentation techniques. The analytical method used is Multiple Linear Regression Analysis. The results showed that: 1. Professionalism, competence, knowledge of financial management and intensity guidance apparatus jointly affect the quality of financial reporting area. 2. Professionalism partially affects the quality of financial reporting area. 3. Competence partially affects the quality of financial reporting area. 4. Knowledge of financial management partially affects the quality of financial reporting area. 5. The intensity guidance apparatus partially affects the quality of financial reporting area.

  8. APPARATUS FOR THE PRODUCTION OF LITHIUM METAL

    Science.gov (United States)

    Baker, P.S.; Duncan, F.R.; Greene, H.B.

    1961-08-22

    Methods and apparatus for the production of high-purity lithium from lithium halides are described. The apparatus is provided for continuously contacting a molten lithium halide with molten barium, thereby forming lithium metal and a barium halide, establishing separate layers of these reaction products and unreacted barium and lithium halide, and continuously withdrawing lithium and barium halide from the reaction zone. (AEC)

  9. Apparatus to simulate nuclear heating in advanced fuels

    International Nuclear Information System (INIS)

    Wrona, B.J.; Galvin, T.M.; Johanson, E.

    1976-10-01

    A direct-electrical-heating apparatus has been built to simulate in-reactor temperature gradients and heating conditions in both the mixed nitrides and carbides of uranium and plutonium. The apparatus has the capability for the investigation and direct observation of fuel-behavior phenomena that should significantly enlarge the data base on mixed carbides and nitrides at temperatures near and above their melting points. In addition to heating UC, results of prooftests showed that the apparatus has the capability to heat graphite, 30 vol % ZrC in graphite, B 4 C control-rod pellets, and stainless steel

  10. Research technique and experimental device for thermal conductivity measurements of refractory compounds

    International Nuclear Information System (INIS)

    Vishnevetskaya, I.A.; Petrov, V.A.

    1977-01-01

    Proposed is a new axial technique for determining thermal conductivity coefficient of solids at temperatures above 1000 deg C with the use of internal heating of specimens by passing electric current and with experimental determining the thermal flows on the lateral side of the working section of the specimen. This method is usable for investigating the thermal conductivity of materials whose surface radiation characteristics are unknown or unstable and for carrying out experiments not only in vacuum, but also in various atmospheres. The overall fiducial error of the results of the method is evaluated at 4-5 % within the range of temperatures between 1200 and 2300 K. A description of the experimental installation is given

  11. Lessons learned from nanoscale specimens tested by MEMS-based apparatus

    Science.gov (United States)

    Elhebeary, Mohamed; Saif, M. Taher A.

    2017-06-01

    The last two decades were marked by the innovative synthesis of nanomaterials and devices. The success of these devices hinges on the mechanical properties of nanomaterials and an understanding of their deformation and failure mechanisms. Many novel testing techniques have been developed to test materials at small scale. This paper reviews the state-of-the-art microelectromechanical systems (MEMS) apparatus developed to characterize materials at nanoscale, and the key insights gained on structure-property relations of materials through these characterizations. Finally, new applications of MEMS in testing living materials, such as tissues and cells, for disease diagnosis and prognosis are discussed.

  12. Lessons learned from nanoscale specimens tested by MEMS-based apparatus

    International Nuclear Information System (INIS)

    Elhebeary, Mohamed; Saif, M Taher A

    2017-01-01

    The last two decades were marked by the innovative synthesis of nanomaterials and devices. The success of these devices hinges on the mechanical properties of nanomaterials and an understanding of their deformation and failure mechanisms. Many novel testing techniques have been developed to test materials at small scale. This paper reviews the state-of-the-art microelectromechanical systems (MEMS) apparatus developed to characterize materials at nanoscale, and the key insights gained on structure-property relations of materials through these characterizations. Finally, new applications of MEMS in testing living materials, such as tissues and cells, for disease diagnosis and prognosis are discussed. (topical review)

  13. Apparatus for gas phase studies at lambda greater than or equal to 300 A

    International Nuclear Information System (INIS)

    Grover, J.R.; White, M.G.

    1981-01-01

    An apparatus is being built to achieve four criteria: (1) a working region of wavelengths from 300 A to 2000 A; (2) absence of all orders higher than the first; (3) intensities as high as possible; (4) able to deal with a significant gas load in the experimental chamber. In exchange for high intensity and excellent order sorting it is acceptable to have only modest resolution, and to forego wavelengths shorter than 300 A

  14. Apparatus for the measurement of density-thickness by use of radiation

    International Nuclear Information System (INIS)

    Buchnea, A.

    1983-01-01

    The invention is used in on-line apparatus for continuously monitoring a property of a moving length of materials in which a source of radiation and a detector are mounted in spaced relationship at an on-line location at which the moving length is permitted to pass between the source and the detector. The invention involves an apparatus for calibrating the monitoring apparatus without moving the monitoring apparatus from the on-line location

  15. Apparatus for control of mercury

    Science.gov (United States)

    Downs, William; Bailey, Ralph T.

    2001-01-01

    A method and apparatus for reducing mercury in industrial gases such as the flue gas produced by the combustion of fossil fuels such as coal adds hydrogen sulfide to the flue gas in or just before a scrubber of the industrial process which contains the wet scrubber. The method and apparatus of the present invention is applicable to installations employing either wet or dry scrubber flue gas desulfurization systems. The present invention uses kraft green liquor as a source for hydrogen sulfide and/or the injection of mineral acids into the green liquor to release vaporous hydrogen sulfide in order to form mercury sulfide solids.

  16. Uranium dioxide calcining apparatus and method

    International Nuclear Information System (INIS)

    Cole, E.A.; Peterson, R.S.

    1978-01-01

    This invention relates to an improved continuous calcining apparatus for consistently and controllably producing from calcinable reactive solid compounds of uranium, such as ammonium diuranate, uranium dioxide (UO 2 ) having an oxygen to uranium ratio of less than 2.2. The apparatus comprises means at the outlet end of a calciner kiln for receiving hot UO 2 , means for cooling the UO 2 to a temperature of below 100 0 C and conveying the cooled UO 2 to storage or to subsequent UO 2 processing apparatus where it finally comes into contact with air, the means for receiving, cooling and conveying being sealed to the outlet end of the calciner and being maintained full of UO 2 and so operable as to exclude atmospheric oxygen from coming into contact with any UO 2 which is at elevated temperatures where it would readily oxidize, without the use of extra hydrogen gas in said means

  17. Nuclear magnetic resonance method and apparatus

    International Nuclear Information System (INIS)

    Burl, M.; Young, I.R.

    1984-01-01

    A method and apparatus for determining the rate of flow of a liquid in a selected region of a body by nuclear magnetic resonance techniques are described. The method includes a sequence of applying a first magnetic pulse effective to excite nuclear magnetic resonance of a chosen nucleus within the liquid preferentially in a slice of the body which includes the selected region. A period of time (tsub(D)) is waited and then a second magnetic pulse is applied which is effective to excite nuclear magnetic resonance of the nuclei preferentially in the slice, and the free induction decay signal is measured. The whole sequence is repeated for different values of the period of time (tsub(D)). The variation in the value of the measured signal with tsub(D) is then related to the rate of flow of the liquid through the slice. (author)

  18. Experimental study of biotin-avidin pretargeting technique for anti-CEA McAb radioimmunoimaging

    International Nuclear Information System (INIS)

    Sun Jianzhong; Zhu Chengmo; Guan Liang; Li Biao; Zhang Jixian; Shi Ailan; Zhang Suyin

    1996-01-01

    Biotin-avidin pretargeting technique was used in promoting the diagnostic efficacy of anti-CEA McAb radioimmunoimaging. CEA McAb was conjugated with biotin McAb (B-McAb), streptavidin (SA) was labeled with 131 I ( 131 I-SA) and DTPA-biotin with 111 In( 111 In-DTPA-B). Experimental human colonic tumor bearing nude mice were used. Two step method: B-McAb was preinjected, followed by 131 I SA 48h later, 24, 48, 96 and 120 h postinjection, γ-imaging and biodistribution were studied. Three step method: B-McAb was preinjected, followed by cold SA 24h later and 111 In-DTPA-B another 24h later. 2,6,24 and 48h postinjection, γ-imaging and biodistribution were also studied. Two step method: T/NT of all organs in experimental group was significantly increased compared with controls. The blood T/NT in experimental group and control group at 24 and 120h was 1.11:0.42 and 8.58:3.51, respectively. Tumor % ID/g in all organs slightly decreased compared with direct group. In γ-imaging radioactivity has been accumulated in tumor site as early as 24h, while only slightly visualized or non-visualized in controls. Three step method: in experimental group the blood T/NT reached 4.19 at 2 h, whereas all was < 1.37 at each phase of controls, the T/NT of all organs was also higher in experimental grouped than in controls. The tumor % ID/g in experimental group was 9.72% at 2h and 3.65% at 48h whereas % ID/g in controls in all phases was <3.07. The tumor clearly visualized at 2h and clearer at 48h in γ-imaging. In controls, the tumor was slightly visualized also to early stage, but faded away later on. Biotin-avidin pretargeting technique can elevate the T/NT ratio and decrease the blood background. Early imaging was obtained with better imaging quality

  19. Superconducting magnetic energy storage apparatus structural support system

    Science.gov (United States)

    Withers, Gregory J.; Meier, Stephen W.; Walter, Robert J.; Child, Michael D.; DeGraaf, Douglas W.

    1992-01-01

    A superconducting magnetic energy storage apparatus comprising a cylindrical superconducting coil; a cylindrical coil containment vessel enclosing the coil and adapted to hold a liquid, such as liquefied helium; and a cylindrical vacuum vessel enclosing the coil containment vessel and located in a restraining structure having inner and outer circumferential walls and a floor; the apparatus being provided with horizontal compression members between (1) the coil and the coil containment vessel and (2) between the coil containment vessel and the vacuum vessel, compression bearing members between the vacuum vessel and the restraining structure inner and outer walls, vertical support members (1) between the coil bottom and the coil containment vessel bottom and (2) between the coil containment vessel bottom and the vacuum vessel bottom, and external supports between the vacuum vessel bottom and the restraining structure floor, whereby the loads developed by thermal and magnetic energy changes in the apparatus can be accommodated and the structural integrity of the apparatus be maintained.

  20. Pulsed wire discharge apparatus for mass production of copper nanopowders.

    Science.gov (United States)

    Suematsu, H; Nishimura, S; Murai, K; Hayashi, Y; Suzuki, T; Nakayama, T; Jiang, W; Yamazaki, A; Seki, K; Niihara, K

    2007-05-01

    A pulsed wire discharge (PWD) apparatus for the mass production of nanopowders has been developed. The apparatus has a continuous wire feeder, which is operated in synchronization with a discharging circuit. The apparatus is designed for operation at a maximum repetition rate of 1.4 Hz at a stored energy of 160 J. In the present study, Cu nanopowder was synthesized using the PWD apparatus and the performance of the apparatus was examined. Cu nanopowder of 2.0 g quantity was prepared in N(2) gas at 100 kPa for 90 s. The particle size distribution of the Cu nanopowder was analyzed by transmission electron microscopy and the mean surface diameter was determined to be 65 nm. The ratio of the production mass of the powder to input energy was 362 g/kW h.

  1. Detection of corrosion by a radiometric technique

    International Nuclear Information System (INIS)

    Charlton, J.S.; Ross, J.F.

    1975-01-01

    A method is described for the detection and measurement of corrosion in metal tube bundles using a radioisotope technique. The method is stated to be accurate and quick, and dismantling is unnecessary. A radioactive source is inserted into one of the tubes of the bundle and radiation detectors are inserted into the remainder of the tubes, which may be up to six in number with the apparatus described. The radiation absorption by the walls of each pair of tubes is compared with a standard measurement representing a known thickness of the material of the tubes. Simultaneous measurements may be made. Suitable apparatus is described in detail. (U.K.)

  2. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  3. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-01-01

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  4. Multipurpose modular experimental station for the DiProI beamline of Fermi-Elettra free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Pedersoli, Emanuele; Capotondi, Flavio; Cocco, Daniele; Kaulich, Burkhard; Menk, Ralf H; Locatelli, Andrea; Mentes, Tevfik O; Spezzani, Carlo; Sandrin, Gilio; Bacescu, Daniel M; Kiskinova, Maya [Fermi, Elettra Sincrotrone Trieste, SS 14 - km 163.5, 34149 Basovizza, Trieste (Italy); Zangrando, Marco [Fermi, Elettra Sincrotrone Trieste, SS 14 - km 163.5, 34149 Basovizza, Trieste (Italy); IOM CNR, Laboratorio TASC, SS 14 - km 163.5, 34149 Basovizza, Trieste (Italy); Bajt, Sasa; Barthelmess, Miriam [Photon Science, DESY, Notkestrasse 85, 22607 Hamburg (Germany); Barty, Anton; Schulz, Joachim; Gumprecht, Lars [Centre for Free-Electron Laser Science, DESY, Notkestrasse 85, 22607 Hamburg (Germany); Chapman, Henry N [Centre for Free-Electron Laser Science, DESY, Notkestrasse 85, 22607 Hamburg (Germany); University of Hamburg, Notkestrasse 85, 22607 Hamburg (Germany); Nelson, A J; Frank, Matthias [Physical and Life Sciences, LLNL, 7000 East Avenue, Livermore, California 94550 (United States); others, and

    2011-04-15

    We present a compact modular apparatus with a flexible design that will be operated at the DiProI beamline of the Fermi-Elettra free electron laser (FEL) for performing static and time-resolved coherent diffraction imaging experiments, taking advantage of the full coherence and variable polarization of the short seeded FEL pulses. The apparatus has been assembled and the potential of the experimental setup is demonstrated by commissioning tests with coherent synchrotron radiation. This multipurpose experimental station will be open to general users after installation at the Fermi-Elettra free electron laser in 2011.

  5. Multipurpose modular experimental station for the DiProI beamline of Fermi-Elettra free electron laser

    International Nuclear Information System (INIS)

    Pedersoli, Emanuele; Capotondi, Flavio; Cocco, Daniele; Kaulich, Burkhard; Menk, Ralf H.; Locatelli, Andrea; Mentes, Tevfik O.; Spezzani, Carlo; Sandrin, Gilio; Bacescu, Daniel M.; Kiskinova, Maya; Zangrando, Marco; Bajt, Sasa; Barthelmess, Miriam; Barty, Anton; Schulz, Joachim; Gumprecht, Lars; Chapman, Henry N.; Nelson, A. J.; Frank, Matthias

    2011-01-01

    We present a compact modular apparatus with a flexible design that will be operated at the DiProI beamline of the Fermi-Elettra free electron laser (FEL) for performing static and time-resolved coherent diffraction imaging experiments, taking advantage of the full coherence and variable polarization of the short seeded FEL pulses. The apparatus has been assembled and the potential of the experimental setup is demonstrated by commissioning tests with coherent synchrotron radiation. This multipurpose experimental station will be open to general users after installation at the Fermi-Elettra free electron laser in 2011.

  6. Grinding assembly, grinding apparatus, weld joint defect repair system, and methods

    Science.gov (United States)

    Larsen, Eric D.; Watkins, Arthur D.; Bitsoi, Rodney J.; Pace, David P.

    2005-09-27

    A grinding assembly for grinding a weld joint of a workpiece includes a grinder apparatus, a grinder apparatus includes a grinding wheel configured to grind the weld joint, a member configured to receive the grinding wheel, the member being configured to be removably attached to the grinder apparatus, and a sensor assembly configured to detect a contact between the grinding wheel and the workpiece. The grinding assembly also includes a processing circuitry in communication with the grinder apparatus and configured to control operations of the grinder apparatus, the processing circuitry configured to receive weld defect information of the weld joint from an inspection assembly to create a contour grinding profile to grind the weld joint in a predetermined shape based on the received weld defect information, and a manipulator having an end configured to carry the grinder apparatus, the manipulator further configured to operate in multiple dimensions.

  7. Calibrating the CsI(Tl) detectors of the GARFIELD apparatus

    CERN Document Server

    Abbondanno, U; Casini, G; Cavaletti, R; Cavallaro, S; Chiari, M; D'Agostino, M; Gramegna, F; Lanchais, A; Margagliotti, G V; Mastinu, P F; Milazzo, P M; Moroni, A; Nannini, A; Ordine, A; Vannini, G; Vannucci, L

    2002-01-01

    The energy and charge dependence of the light output of the CsI(Tl) detectors of the GARFIELD apparatus has been investigated for heavy ions with 5<=Z<=16 in the energy range from 2.2 to 8.3 A MeV. The results have been compared to an analytical expression successfully used in previous calibration procedures at higher energies, and a rather good agreement was obtained between measured and calculated quantities. The resulting parameter set was successfully applied to another set of experimental data. The overall result demonstrates the validity of the above mentioned calibration procedure in a wide range of incident ion energies and masses.

  8. System, methods and apparatus for program optimization for multi-threaded processor architectures

    Science.gov (United States)

    Bastoul, Cedric; Lethin, Richard A; Leung, Allen K; Meister, Benoit J; Szilagyi, Peter; Vasilache, Nicolas T; Wohlford, David E

    2015-01-06

    Methods, apparatus and computer software product for source code optimization are provided. In an exemplary embodiment, a first custom computing apparatus is used to optimize the execution of source code on a second computing apparatus. In this embodiment, the first custom computing apparatus contains a memory, a storage medium and at least one processor with at least one multi-stage execution unit. The second computing apparatus contains at least two multi-stage execution units that allow for parallel execution of tasks. The first custom computing apparatus optimizes the code for parallelism, locality of operations and contiguity of memory accesses on the second computing apparatus. This Abstract is provided for the sole purpose of complying with the Abstract requirement rules. This Abstract is submitted with the explicit understanding that it will not be used to interpret or to limit the scope or the meaning of the claims.

  9. Integration of computational modeling and experimental techniques to design fuel surrogates

    DEFF Research Database (Denmark)

    Choudhury, H.A.; Intikhab, S.; Kalakul, Sawitree

    2017-01-01

    performance. A simplified alternative is to develop surrogate fuels that have fewer compounds and emulate certain important desired physical properties of the target fuels. Six gasoline blends were formulated through a computer aided model based technique “Mixed Integer Non-Linear Programming” (MINLP...... Virtual Process-Product Design Laboratory (VPPD-Lab) are applied onto the defined compositions of the surrogate gasoline. The aim is to primarily verify the defined composition of gasoline by means of VPPD-Lab. ρ, η and RVP are calculated with more accuracy and constraints such as distillation curve...... and flash point on the blend design are also considered. A post-design experiment-based verification step is proposed to further improve and fine-tune the “best” selected gasoline blends following the computation work. Here, advanced experimental techniques are used to measure the RVP, ρ, η, RON...

  10. A superheterodyne spectrometer for electronic paramagnetic. Resonance

    International Nuclear Information System (INIS)

    Laffon, J.L.

    1963-12-01

    After a few generalities about electron paramagnetic resonance, a consideration of different experimental techniques authorises the choice of a particular type of apparatus. An EPR superheterodyne spectrometer built in the laboratory and having a novel circuit is described in detail. With this apparatus, many experimental results have been obtained and some of these are described as example. (author) [fr

  11. Article separation apparatus and method for unit operations

    Science.gov (United States)

    Pardini, Allan F.; Gervais, Kevin L.; Mathews, Royce A.; Hockey, Ronald L.

    2010-06-22

    An apparatus and method are disclosed for separating articles from a group of articles. The apparatus includes a container for containing one or more articles coupled to a suitable fluidizer for suspending articles within the container and transporting articles to an induction tube. A portal in the induction tube introduces articles singly into the induction tube. A vacuum pulls articles through the induction tube separating the articles from the group of articles in the container. The apparatus and method can be combined with one or more unit operations or modules, e.g., for inspecting articles, assessing quality of articles, or ascertaining material properties and/or parameters of articles, including layers thereof.

  12. Phase change thermal control materials, method and apparatus

    Science.gov (United States)

    Buckley, Theresa M. (Inventor)

    2001-01-01

    An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

  13. Continuously rotating cat scanning apparatus and method

    International Nuclear Information System (INIS)

    Bax, R.F.

    1980-01-01

    A tomographic scanner with a continuously rotating source of radiation is energized by converting inertial mechanical energy to electrical energy. The mechanical-to-electrical conversion apparatus is mounted with the x-ray source to be energized on a rotating flywheel. The inertial mechanical energy stored in the rotating conversion apparatus, flywheel and x-ray source is utilized for generating electrical energy used, in turn, to energize the x-ray source

  14. Apparatus for controlling nuclear core debris

    Science.gov (United States)

    Jones, Robert D.

    1978-01-01

    Nuclear reactor apparatus for containing, cooling, and dispersing reactor debris assumed to flow from the core area in the unlikely event of an accident causing core meltdown. The apparatus includes a plurality of horizontally disposed vertically spaced plates, having depressions to contain debris in controlled amounts, and a plurality of holes therein which provide natural circulation cooling and a path for debris to continue flowing downward to the plate beneath. The uppermost plates may also include generally vertical sections which form annular-like flow areas which assist the natural circulation cooling.

  15. Apparatus for controlling nuclear core debris

    International Nuclear Information System (INIS)

    Jones, R.D.

    1978-01-01

    Disclosed is an apparatus for containing, cooling, and dispersing reactor debris assumed to flow from the core area in the unlikely event of an accident causing core meltdown. The apparatus includes a plurality of horizontally disposed vertically spaced plates, having depressions to contain debris in controlled amounts, and a plurality of holes therein which provide natural circulation cooling and a path for debris to continue flowing downward to the plate beneath. The uppermost plates may also include generally vertical sections which form annular-like flow areas which assist the natural circulation cooling

  16. Programmers for diagnostic x-ray apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Novel apparatus is described for providing a pre-programmed selection of various parameters in X-ray radiography. The equipment consists of push-buttons which prompt the radiographer to make decisions such as thickness of patient, part of the anatomy to be X-rayed etc. From these data the apparatus selects the appropriate parameters such as H.T. voltage, current, product of current and irradiation time etc. The values of these parameters are displayed to the radiographer and facilities are provided to override the programmed parameters at the radiographer's discretion. (U.K.)

  17. Radiography apparatus

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1985-01-01

    Apparatus for the inspection of pipe welds comprises a radiation source for transmitting radiation, say as X-rays, through a pipe weld and a detector in a box arranged diametrically opposite the source, with respect to the pipe, for detecting the transmitted radiation and providing electrical signals which are processed to produce an image of the weld. The source and detector are mounted on a frame which is rotatable about an inner frame clamped to the pipe. (author)

  18. [Mathematical apparatus of the circuit theory in modeling of heat transfer upon extreme heating of an organism].

    Science.gov (United States)

    2010-01-01

    The mathematical model of heat transfer in whole-body hyperthermia, developed earlier by the author, has been refined using the mathematical apparatus of the circuit theory. The model can be used to calculate the temperature of each organ, which can increase the efficacy and safety of the immersion-convection technique of whole-body hyperthermia.

  19. Imaging Apparatus And Method

    NARCIS (Netherlands)

    Manohar, Srirang; van Leeuwen, A.G.J.M.

    2010-01-01

    A thermoacoustic imaging apparatus comprises an electromagnetic radiation source configured to irradiate a sample area and an acoustic signal detection probe arrangement for detecting acoustic signals. A radiation responsive acoustic signal generator is added outside the sample area. The detection

  20. IMAGING APPARATUS AND METHOD

    NARCIS (Netherlands)

    Manohar, Srirang; van Leeuwen, A.G.J.M.

    2008-01-01

    A thermoacoustic imaging apparatus comprises an electromagnetic radiation source configured to irradiate a sample area and an acoustic signal detection probe arrangement for detecting acoustic signals. A radiation responsive acoustic signal generator is added outside the sample area. The detection

  1. Nuclear fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    Gerkey, K.S.

    1979-01-01

    An automatic apparatus for loading a predetermined amount of nuclear fuel pellets into a nuclear fuel element to be used in a nuclear reactor is described. The apparatus consists of a vibratory bed capable of supporting corrugated trays containing rows of nuclear fuel pellets and arranged in alignment with the open ends of several nuclear fuel elements. A sweep mechanism is arranged above the trays and serves to sweep the rows of fuel pellets onto the vibratory bed and into the fuel element. A length detecting system, in conjunction with a pellet stopping mechanism, is also provided to assure that a predetermined amount of nuclear fuel pellets are loaded into each fuel element

  2. Experimental Study on Indoor Air Cleaning Technique of Nano-Titania Catalysis Under Plasma Discharge

    International Nuclear Information System (INIS)

    Gao Deli; Yang Xuechang; Zhou Fei; Wu Yuhuang

    2008-01-01

    In this study, a new technique of air cleaning by plasma combined with catalyst was proposed, which consisted of electrostatic precipitation, volatile organic compounds (VOCs) decomposition and sterilization. A novel indoor air purifier based on this technique was adopted. The experimental results showed that formaldehyde decomposition by the plasma-catalyst hybrid system was more efficient than that by plasma only. Positive discharge was better than negative discharge in formaldehyde removal. Meanwhile, the outlet concentration of ozone byproduct was effectively reduced by the nano-titania catalyst.

  3. Coulomb-explosion technique for determining geometrical structures of molecular ions

    International Nuclear Information System (INIS)

    Gemmell, D.S.

    1981-01-01

    Traditional experimental techniques (e.g. studies on photon absorption or emission) for determining the sterochemical structures of neutral molecules are extremeley difficult to apply to molecular ions because of problems in obtaining a sufficient spatial density of the ions to be studied. Recent high-resolution measurements on the energy and angle distributions of the fragments produced when fast (MeV) molecular-ion beams from an electrostatic accelerator dissociate (Coulomb explode) in thin foils and in gases, offer promising possibilities for deducing the sterochemical structures of the molecular ions constituting the incident beams. Bond lengths have been determined in this way for several diatomic projectiles (H 2+ , HeH + , CH + , NH + , OH + , N 2+ , O 2+ , etc.) with an accuracy of approx. 0.01 A. H 3+ has been demonstrated (for the first time) to be equilateral triangular and the interproton distance measured. Measurements on single fragments from CO 2+ , N 2 O + , C 3 H 3+ , and CH/sub n/ + have revealed the gross structures of the projectiles. An apparatus has recently been constructed at Argonne to permit precise measurements on fragments in coincidence. The apparatus has been tested on a known structure (OH 2+ ). The O-H bond length was found to be 1.0 +- 0.04 A and the H-O-H bond angle was measured as 110 --- 2 0 . These values are in excellent agreement with those found in optical experiments (0.999 A and 110.5 0 ). This Coulomb explosion technique can be expected to be refined in accuracy and to be extended to a wide range of molecular ions whose structures are inaccessible by other means

  4. Development of apparatus for surveying uranium surface contamination quantity

    International Nuclear Information System (INIS)

    Wang Qingheng; Han Jingquan

    1994-11-01

    An apparatus for measuring uranium contamination of the surface of reactor plate component is described. The searching unit of the apparatus is a large surface multi-wire proportional counter. The cathode of the counter is made of stainless steel with low radioactive background, the window is made of film which is plated with aluminum about 6 μm; and the anode is mad by gild tungsten wire of 0.025 mm diameter. The sensitive area of the counter is 1113 mm x 100 mm. It has been shown that the intrinsic radioactive background of the apparatus is 0.002 cpm/cm 2 (2 count/min). The detecting efficiency is 67% for enriched uranium source (2π solid angle). The stability is 0.84% within 24 hour (including detector, high voltage power supply, amplifier, discriminator, computer, type and display system). The lower detection limit of the apparatus is 4.6 x 10 -10 g/cm 2 (for 20% 235 U, 0.13% 234 U, 79.64% 238 U). The apparatus can present timing by a computer controlling, and it also has the following functions: displaying, automatic alarming, classifying and typing the results. (2 tabs., 7 figs.)

  5. Apparatus for reducing pulse pileup in an elemental analyzer measuring gamma rays arising from neutron capture in bulk substances

    International Nuclear Information System (INIS)

    Marshall, J.H. III.

    1979-01-01

    The active reduction of the number of analyzed events with pulse amplitudes which pileup has distorted improves measurement accuracy and response time in an apparatus for neutron-capture-based on-line elemental analysis of bulk substances. Within the apparatus, the analyzed bulk substance is exposed to neutrons, and neutron capture generates prompt gamma rays therefrom. A detector interacts with some of these gamma rays to produce electrical signals used to measure their energy spectrum by pulse-height analysis. Circuits associated with this pulse-height analysis also detect the pileup of the signals of two or more independent gamma rays using one or more of several techniques. These techniques include multiple outputs from a special amplifier-discriminator system, which has been optimized for low pulse-pair resolving time and may have adaptive thresholds, and the requirement that the relative amplitudes of the outputs of slow and fast amplifiers be consistent with a single event producing both outputs. Pulse-width measurements are also included in the pileup detection

  6. Method and apparatus for analyzing ionizable materials

    International Nuclear Information System (INIS)

    Ehrlich, B.J.; Hall, R.C.; Thiede, P.W.

    1979-01-01

    An apparatus and method are described for analyzing a solution of ionizable compounds in a liquid. The solution is irradiated with electromagnetic radiation to ionize the compounds and the electrical conductivity of the solution is measured. The radiation may be X-rays, ultra-violet, infra-red or microwaves. The solution may be split into two streams, only one of which is irradiated, the other being used as a reference by comparing conductivities of the two streams. The liquid must be nonionizable and is preferably a polar solvent. The invention provides an analysis technique useful in liquid chromatography and in gas chromatography after dissolving the eluted gases in a suitable solvent. Electrical conductivity measurements performed on the irradiated eluent provide a quantitative indication of the ionizable materials existing within the eluent stream and a qualitative indication of the purity of the eluent stream. (author)

  7. Jumping Stand Apparatus Reveals Rapidly Specific Age-Related Cognitive Impairments in Mouse Lemur Primates.

    Directory of Open Access Journals (Sweden)

    Jean-Luc Picq

    Full Text Available The mouse lemur (Microcebus murinus is a promising primate model for investigating normal and pathological cerebral aging. The locomotor behavior of this arboreal primate is characterized by jumps to and from trunks and branches. Many reports indicate insufficient adaptation of the mouse lemur to experimental devices used to evaluate its cognition, which is an impediment to the efficient use of this animal in research. In order to develop cognitive testing methods appropriate to the behavioral and biological traits of this species, we adapted the Lashley jumping stand apparatus, initially designed for rats, to the mouse lemur. We used this jumping stand apparatus to compare performances of young (n = 12 and aged (n = 8 adults in acquisition and long-term retention of visual discriminations. All mouse lemurs completed the tasks and only 25 trials, on average, were needed to master the first discrimination problem with no age-related differences. A month later, all mouse lemurs made progress for acquiring the second discrimination problem but only the young group reached immediately the criterion in the retention test of the first discrimination problem. This study shows that the jumping stand apparatus allows rapid and efficient evaluation of cognition in mouse lemurs and demonstrates that about half of the old mouse lemurs display a specific deficit in long-term retention but not in acquisition of visual discrimination.

  8. Apparatus and process for passivating an SRF cavity

    Science.gov (United States)

    Myneni, Ganapati Rao; Wallace, John P

    2014-12-02

    An apparatus and process for the production of a niobium cavity exhibiting high quality factors at high gradients is provided. The apparatus comprises a first chamber positioned within a second chamber, an RF generator and vacuum pumping systems. The process comprises placing the niobium cavity in a first chamber of the apparatus; thermally treating the cavity by high temperature in the first chamber while maintaining high vacuum in the first and second chambers; and applying a passivating thin film layer to a surface of the cavity in the presence of a gaseous mixture and an RF field. Further a niobium cavity exhibiting high quality factors at high gradients produced by the method of the invention is provided.

  9. Measurement of scintillation decay curves by a single photon counting technique

    International Nuclear Information System (INIS)

    Noguchi, Tsutomu

    1978-01-01

    An improved apparatus suitable for the measurement of spectroscopic scintillation decay curves has been developed by combination of a single photon counting technique and a delayed coincidence method. The time resolution of the apparatus is improved up to 1.16 nsec (FWHM), which is obtained from the resolution function of the system for very weak Cherenkov light flashes. Systematic measurement of scintillation decay curves is made for liquid and crystal scintillators including PPO-toluene, PBD-xylene, PPO-POPOP-toluene, anthracene and stilbene. (auth.)

  10. Pressure suppression apparatus of a nuclear power plant

    International Nuclear Information System (INIS)

    Mizumachi, W.; Funalashi, T.

    1980-01-01

    Pressure suppression apparatus for a nuclear reactor comprises a vessel surrounding a reactor pressure vessel and containing a water pool at the bottom of the vessel, and a steam exhaust pipe. The apparatus further comprises an exhaust chamber connected to the immersed portion of the exhaust pipe and provided with a number of discharge openings. (auth)

  11. Progress in nuclear measuring and experimental techniques by application of microelectronics. 1

    International Nuclear Information System (INIS)

    Meiling, W.

    1984-01-01

    In the past decade considerable progress has been made in nuclear measuring and experimental techniques by developing position-sensitive detector systems and widely using integrated circuits and microcomputers for data acquisition and processing as well as for automation of measuring processes. In this report which will be published in three parts those developments are reviewed and demonstrated on selected examples. After briefly characterizing microelectronics, the use of microelectronic elements for radiation detectors is reviewed. (author)

  12. Mobile lighting apparatus

    Science.gov (United States)

    Roe, George Michael; Klebanoff, Leonard Elliott; Rea, Gerald W; Drake, Robert A; Johnson, Terry A; Wingert, Steven John; Damberger, Thomas A; Skradski, Thomas J; Radley, Christopher James; Oros, James M; Schuttinger, Paul G; Grupp, David J; Prey, Stephen Carl

    2013-05-14

    A mobile lighting apparatus includes a portable frame such as a moveable trailer or skid having a light tower thereon. The light tower is moveable from a stowed position to a deployed position. A hydrogen-powered fuel cell is located on the portable frame to provide electrical power to an array of the energy efficient lights located on the light tower.

  13. FY 1998 annual report on the leading fundamental research and development of AC superconducting power apparatuses (New Sunshine Project); 1998 nendo koryu chodendo denryoku kiki kiban sendo kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    In order to propose fundamental research and development of AC superconducting power apparatuses, the FY 1998 efforts were directed to studies on the effects of introducing superconducting apparatuses, making proposals of development programs, literature (including patent publications) surveys on trends of research and development at home and abroad, and making proposals for technological breakthroughs. Results of the studies for evaluating economic efficiency of these apparatuses and the effects of their introduction indicate that the promising apparatuses for eventual commercialization include superconducting cables, current limiters, field power generators, transformers and flywheels. The superconducting cables are expected to greatly reduce losses and hence CO2 emissions. The superconducting current limiters are promising means to control short-circuit current increase in the trunk power systems in which they are used. The superconducting transformers are expected to reduce losses and hence CO2 emissions. The project of fundamental research and development of AC superconducting power apparatuses has proposed the fundamental technological research themes aimed at development of the elementary techniques prerequisite for realizing these 3 types of apparatuses and reflection of the required apparatus specifications in development of the cable materials. (NEDO)

  14. 46 CFR 160.010-5 - Buoyant apparatus with plastic foam buoyancy.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Buoyant apparatus with plastic foam buoyancy. 160.010-5... Vessels § 160.010-5 Buoyant apparatus with plastic foam buoyancy. (a) Buoyant apparatus with plastic foam buoyancy must have a plastic foam body with an external protective covering. The body may be reinforced as...

  15. Past and present of measuring apparatus for nuclear medicine

    International Nuclear Information System (INIS)

    Murayama, Hideo

    2013-01-01

    The history of advancement of measuring apparatus for nuclear medicine is looked back. It is presented that Japanese contribution to these advancement has been in no small quantities. The future view carrying the measuring apparatus for nuclear medicine is also described. (M.H.)

  16. 46 CFR 160.010-6 - Capacity of buoyant apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Capacity of buoyant apparatus. 160.010-6 Section 160.010-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND... apparatus is not considered in determining the capacity. (b) [Reserved] ...

  17. Simulant-material experimental investigation of flow dynamics in the CRBR Upper-Core Structure

    International Nuclear Information System (INIS)

    Wilhelm, D.; Starkovich, V.S.; Chapyak, E.J.

    1982-09-01

    The results of a simulant-material experimental investigation of flow dynamics in the Clinch River Breeder Reactor (CRBR) Upper Core Structure are described. The methodology used to design the experimental apparatus and select test conditions is detailed. Numerous comparisons between experimental data and SIMMER-II Code calculations are presented with both advantages and limitations of the SIMMER modeling features identified

  18. Experimental study of natural two-phase flow circulation using a visualization technique

    International Nuclear Information System (INIS)

    Vinhas, Pedro A.M.; Su, Jian

    2013-01-01

    This paper presents an experimental study of natural two-phase flow in a circuit that simulates, on a smaller scale, a typical residual heat removal system of passive reactors APWR (Advanced Pressurized Water Reactor). The circuit was formed by a heater, a heat exchanger and piping. The experimental study was the application of a visualization technique, using a high speed camera, for measuring the size and speed of vapor bubbles generated in the heater with different power heating. The camera was positioned in the central region of the pipe connecting the heater to the heat exchanger, where there is a clear passage. The flow of images were processed and analyzed using commercial software that allowed the determination of the length and velocity of the bubbles. The results were then compared with correlations available in literature

  19. Apparatus for handling control rod drives

    International Nuclear Information System (INIS)

    Akimoto, A.; Watanabe, M.; Yoshida, T.; Sugaya, Z.; Saito, T.; Ishii, Y.

    1979-01-01

    An apparatus for handling control rod drives (CRD's) attached by detachable fixing means to housings mounted in a reactor pressure vessel and each coupled to one of control rods inserted in the reactor pressure vessel is described. The apparatus for handling the CRD's comprise cylindrical housing means, uncoupling means mounted in the housing means for uncoupling each of the control rods from the respective CRD, means mounted on the housing means for effecting attaching and detaching of the fixing means, means for supporting the housing means, and means for moving the support means longitudinally of the CRD

  20. Development of counting system for wear measurements using Thin Layer Activation and the Wearing Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    França, Michel de A.; Suita, Julio C.; Salgado, César M., E-mail: mchldante@gmail.com, E-mail: suita@ien.gov.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    This paper focus on developing a counting system for the Wearing Apparatus, which is a device previously built to generate measurable wear on a given surface (Main Source) and to carry the fillings from it to a filter (second source). The Thin Layer Activation is a technique used to produce activity on one of the Wearing Apparatus' piece, this activity is proportional to the amount of material worn, or scrapped, from the piece's surface. Thus, by measuring the activity on those two points it is possible to measure the produced wear. The methodology used in this work is based on simulations through MCNP-X Code to nd the best specifications for shielding, solid angles, detectors dimensions and collimation for the Counting System. By simulating several scenarios, each one different from the other, and analyzing the results in the form of Counts Per Second, the ideal counting system's specifications and geometry to measure the activity in the Main Source and the Filter (second source) is chosen. After that, a set of previously activated stainless steel foils were used to reproduce the real experiments' conditions, this real experiment consists of using TLA and the Wearing Apparatus, the results demonstrate that the counting system and methodology are adequate for such experiments. (author)

  1. Data mining and visualization techniques

    Science.gov (United States)

    Wong, Pak Chung [Richland, WA; Whitney, Paul [Richland, WA; Thomas, Jim [Richland, WA

    2004-03-23

    Disclosed are association rule identification and visualization methods, systems, and apparatus. An association rule in data mining is an implication of the form X.fwdarw.Y where X is a set of antecedent items and Y is the consequent item. A unique visualization technique that provides multiple antecedent, consequent, confidence, and support information is disclosed to facilitate better presentation of large quantities of complex association rules.

  2. Proton imaging apparatus for proton therapy application

    International Nuclear Information System (INIS)

    Sipala, V.; Lo Presti, D.; Brianzi, M.; Civinini, C.; Bruzzi, M.; Scaringella, M.; Talamonti, C.; Bucciolini, M.; Cirrone, G.A.P.; Cuttone, G.; Randazzo, N.; Stancampiano, C.; Tesi, M.

    2011-01-01

    Radiotherapy with protons, due to the physical properties of these particles, offers several advantages for cancer therapy as compared to the traditional radiotherapy and photons. In the clinical use of proton beams, a p CT (Proton Computer Tomography) apparatus can contribute to improve the accuracy of the patient positioning and dose distribution calculation. In this paper a p CT apparatus built by the Prima (Proton Imaging) Italian Collaboration will be presented and the preliminary results will be discussed.

  3. An experimental system for coiled tubing partial underbalanced drilling (CT-PUBD) technique

    Science.gov (United States)

    Shi, H. Z.; Ji, Z. S.; Zhao, H. Q.; Chen, Z. L.; Zhang, H. Z.

    2018-05-01

    To improve the rate of penetration (ROP) in hard formations, a new high-speed drilling technique called Coiled Tubing Partial Underbalanced Drilling (CT-PUBD) is proposed. This method uses a rotary packer to realize an underbalanced condition near the bit by creating a micro-annulus and an overbalanced condition at the main part of the annulus. A new full-scale laboratory experimental system is designed and set up to study the hydraulic characteristics and drilling performance of this method. The system is composed of a drilling system, circulation system, and monitor system, including three key devices, namely, cuttings discharge device, rotary packer, and backflow device. The experimental results showed that the pressure loss increased linearly with the flow rate of the drilling fluid. The high drilling speed of CT-PUBD proved it a better drilling method than the conventional drilling. The experimental system may provide a fundamental basis for the research of CT-PUBD, and the results proved that this new method is feasible in enhancing ROP and guaranteeing the drilling safety.

  4. Surface science techniques

    CERN Document Server

    Bracco, Gianangelo

    2013-01-01

    The book describes the experimental techniques employed to study surfaces and interfaces. The emphasis is on the experimental method. Therefore all chapters start with an introduction of the scientific problem, the theory necessary to understand how the technique works and how to understand the results. Descriptions of real experimental setups, experimental results at different systems are given to show both the strength and the limits of the technique. In a final part the new developments and possible extensions of the techniques are presented. The included techniques provide microscopic as well as macroscopic information. They cover most of the techniques used in surface science.

  5. THE APPARATUS FOR ALIGNMENT OF THE PHOTOMETRIC LAMP FILAMENT

    Directory of Open Access Journals (Sweden)

    V. A. Dlugunovich

    2015-01-01

    Full Text Available During photometric measurements involving the use of photometric lamps it is necessary that the filament of lamp takes a strictly predetermined position with respect to the photodetector and the optical axis of the photometric setup. The errors in positioning of alignment filament with respect to the optical axis of the measuring system lead to increase the uncertainty of measurement of the photometric characteristics of the light sources. A typical method for alignment of filament of photometric lamps is based on the use a diopter tubes (telescopes. Using this method, the mounting of filament to the required position is carried out by successive approximations, which requires special concentration and a lot of time. The aim of this work is to develop an apparatus for alignment which allows simultaneous alignment of the filament of lamps in two mutually perpendicular planes. The method and apparatus for alignment of the photometric lamp filament during measurements of the photometric characteristics of light sources based on two digital video cameras is described in this paper. The apparatus allows to simultaneously displaying the image of lamps filament on the computer screen in two mutually perpendicular planes. The apparatus eliminates a large number of functional units requiring elementwise alignment and reduces the time required to carry out the alignment. The apparatus also provides the imaging of lamps filament with opaque coated on the bulb. The apparatus is used at the National standard of light intensity and illuminance units of the Republic of Belarus. 

  6. [Design and application of a cake-shaping apparatus for drug-separated moxibustion].

    Science.gov (United States)

    Zhu, Ai-Jun; Lu, Xiao-Dong

    2008-08-01

    Acupuncturist makes herbal cakes with traditional manual way, with such disadvantages as slow in making, varying in thickness and size of the cake. When the patients are treated with medical cake-separated moxibustion, they will be unevenly affected by the heat and the patient easily suffers from burning. These hinder clinically wide application of cake-separated moxibustion. With practice of many years, the authors design and make a kind of manual cake-shaping apparatus which can rapidly and conveniently make uniform medical cake, with simple technique, ingenious structure and normal material.

  7. A Technique for Dynamic Corrosion Testing in Liquid Lead Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Loewen, Eric Paul; Davis, Cliff Bybee; Mac Donald, Philip Elsworth

    2001-04-01

    An experimental apparatus for the investigation of the flow-assisted dissolution and precipitation (corrosion) of potential fuel cladding and structural materials to be used in liquid lead alloy cooled reactors has been designed. This experimental project is part of a larger research effort between Idaho National Engineering and Environmental Laboratory (INEEL) and Massachusetts Institute of Technology to investigate the suitability of lead, lead-bismuth, and other lead alloys for cooling fast reactors designed to produce low-cost electricity as well as for actinide burning. The INEEL forced convection corrosion cell consists of a small heated vessel with a shroud and gas flow system. The gas flow rates, heat input, and shroud and vessel dimensions have been adjusted so that a controlled coolant flow rate, temperature, and oxygen potential are created within the downcomer located between the shroud and vessel wall. The ATHENA computer code was used to design the experimental apparatus and estimate the fluid conditions. The corrosion cell will test steel that is commercially available in the U. S. to temperatures above 650oC.

  8. Experimental Approach of Fault Movement on an Engineered Barrier System

    International Nuclear Information System (INIS)

    Lee, Minsoo; Choi, Heuijoo; Kim, Heuna

    2012-01-01

    Safety evaluation of an engineered barrier system against fault movement at underground disposal region for high level waste (HLW) is tried using a miniature bore-shear apparatus. For the purpose, a miniature bore-shear apparatus simulating an EBS (engineered barrier system) was manufactured in 1/30 scale. And using the developed apparatus, bore-shear tests were performed twice. During the tests, pressure variations were checked at 6 points around buffer zone, and then a rotational angle of the test vessel was checked. The achieved pressure data were compared with those from analytical modeling, which is based on Drucker-Prager model. At initial shearing step, high pressure was recorded at some point but it decreased rapidly. For the better understanding of fault movement, the modification of an analytical model and the accumulation of experimental experience were required

  9. Experimental Approach of Fault Movement on an Engineered Barrier System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Minsoo; Choi, Heuijoo; Kim, Heuna [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-03-15

    Safety evaluation of an engineered barrier system against fault movement at underground disposal region for high level waste (HLW) is tried using a miniature bore-shear apparatus. For the purpose, a miniature bore-shear apparatus simulating an EBS (engineered barrier system) was manufactured in 1/30 scale. And using the developed apparatus, bore-shear tests were performed twice. During the tests, pressure variations were checked at 6 points around buffer zone, and then a rotational angle of the test vessel was checked. The achieved pressure data were compared with those from analytical modeling, which is based on Drucker-Prager model. At initial shearing step, high pressure was recorded at some point but it decreased rapidly. For the better understanding of fault movement, the modification of an analytical model and the accumulation of experimental experience were required.

  10. Method and apparatus for measuring the concentration of water, iron, and aluminum in iron ore by neutron radiation

    International Nuclear Information System (INIS)

    Holmes, R.J.; Wylie, A.W.; McCracken, K.G.

    1975-01-01

    Techniques and apparatus for measuring the concentration of water and specific components in materials are described. The techniques involve irradiating the material with neutrons and monitoring the neutron flux in the vicinity of the irradiated material and the gamma radiation from excited nuclei of the specific component. Examples of the use of the invention include on-stream monitoring of ores carried by conveyor belts and borehole logging using a probe which carries a neutron source, and neutron and gamma radiation detectors. (U.S.)

  11. Experimental study on the particles deposition in the sampling duct

    Energy Technology Data Exchange (ETDEWEB)

    Vendel, J.; Charuau, J. [Institut de Protection et de Surete Nucleaire, Yvette (France)

    1995-02-01

    A high standard of protection against the harmful effects of radioactive aerosol dissemination requires a measurement, as representative as possible, of their concentration. This measurement depends on the techniques used for aerosol sampling and transfer to the detector, as well as on the location of the latter with respect to the potential sources. The aeraulic design of the apparatus is also an important factor. Once collected the aerosol particles often have to travel through a variably shaped duct to the measurement apparatus. This transport is responsible for losses due to the particles deposition on the walls, leading to a distortion on the concentration measurements and a change in the particle size distribution. To estimate and minimize measurement errors it is important to determine the optimal transport conditions when designing a duct; its diameter and material, the radius of curvature of the bends and the flow conditions must be defined in particular. This paper presents an experimental study in order to determine, for each deposition mechanism, the retained fraction, or the deposition velocity for different flow regimes. This study has pointed out that it exists a favourable flow regime for the particle transport through the sampling ducts (2 500 < Re < 5 000). It has been established, for any particle diameters, equations to predict the aerosol penetration in smooth-walled cylindrical metal ducts.

  12. Apparatus for the ammonium recovery from liquid animal manure

    NARCIS (Netherlands)

    Starmans, D.A.J.; Timmerman, M.

    2013-01-01

    Nitrogen present in animal manure can be a limiting factor when considering manure application rates onto arable land. EU-regulations triggered the development of a new ammonia exchange apparatus for the recovery of ammonia. The described apparatus has a liquid to liquid ammonia mass transfer

  13. 49 CFR 234.211 - Security of warning system apparatus.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Security of warning system apparatus. 234.211... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION GRADE CROSSING SIGNAL SYSTEM SAFETY AND STATE ACTION PLANS Maintenance, Inspection, and Testing Maintenance Standards § 234.211 Security of warning system apparatus...

  14. Apparatus and method for the electrolysis of water

    Science.gov (United States)

    Greenbaum, Elias

    2015-04-21

    An apparatus for the electrolytic splitting of water into hydrogen and/or oxygen, the apparatus comprising: (i) at least one lithographically-patternable substrate having a surface; (ii) a plurality of microscaled catalytic electrodes embedded in said surface; (iii) at least one counter electrode in proximity to but not on said surface; (iv) means for collecting evolved hydrogen and/or oxygen gas; (v) electrical powering means for applying a voltage across said plurality of microscaled catalytic electrodes and said at least one counter electrode; and (vi) a container for holding an aqueous electrolyte and housing said plurality of microscaled catalytic electrodes and said at least one counter electrode. Electrolytic processes using the above electrolytic apparatus or functional mimics thereof are also described.

  15. X-ray examination apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Griswa, P.J.; Halter, P. Jr.; Kidd, H.J.

    1980-01-01

    Apparatus for x-ray cardiovascular examination and which can also be used for general purpose examination is described. An advantage of the system is that there is no mechanical connection between the image intensifier and source to interfere with the medical examiner or emergency procedures. (U.K.)

  16. Portable apparatus for measurement of nuclear radiation

    International Nuclear Information System (INIS)

    Whitlock, G.D.

    1975-01-01

    The apparatus described is stated to be particularly applicable to the measurement of tritium contamination of a surface, although it may have other applications to the determination of radioactivity on surfaces. The mean range of a tritium β particle in air at normal atmospheric pressure is only 1.5 mm. and when monitoring such radiation with the apparatus it is necessary to exclude light. The apparatus comprises a plastic scintillator sheet located in the base of a housing, with a sealing ring mounted in the base so as to make a hermetic and light-tight seal between a support surface and the base of the housing. Photomultiplier means are optically coupled to the scintillator sheet to detect and amplify the scintillations, and a pump device is provided to reduce the air pressure in the vicinity of the sheet to below atmospheric pressure. The scintillator sheet and the photomultiplier means are movable as one unit within the housing, the unit being arranged to be acted upon by atmospheric pressure so as to move the unit into an operative position against a spring when the air pressure in the vicinity of the sheet is reduced to below atmospheric pressure. A shutter is provided to prevent exposure of the scintillator sheet to light when the apparatus is not in use. (U.K.)

  17. Evaluated Plan Stress Of Weld In Pressure Tube Using X Ray Diffraction Technique

    International Nuclear Information System (INIS)

    Phan Trong Phuc; Nguyen Duc Thanh; Luu Anh Tuyen

    2011-01-01

    X ray diffraction is a fundamental technique measuring stress, this technique has determined crystal strain in materials, from that determined stress in materials. This paper presents study of evaluating plane stress of weld in pressure tube, using modern XRD apparatus: X Pert Pro. (author)

  18. Apparatus for measurement of the electric dipole moment of the neutron using a cohabiting atomic-mercury magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Baker, C.A. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Chibane, Y.; Chouder, M. [University of Sussex, Falmer, Brighton BN1 9QH (United Kingdom); Geltenbort, P. [Institut Laue-Langevin, BP 156, F-38042 Grenoble Cedex 9 (France); Green, K. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Harris, P.G., E-mail: p.g.harris@sussex.ac.uk [University of Sussex, Falmer, Brighton BN1 9QH (United Kingdom); Heckel, B.R. [Department of Physics, University of Washington, Seattle, WA 98195 (United States); Iaydjiev, P.; Ivanov, S.N.; Kilvington, I. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Lamoreaux, S.K. [Department of Physics, University of Washington, Seattle, WA 98195 (United States); May, D.J.; Pendlebury, J.M.; Richardson, J.D.; Shiers, D.B.; Smith, K.F. [University of Sussex, Falmer, Brighton BN1 9QH (United Kingdom); Grinten, M. van der [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom)

    2014-02-01

    A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter [1]; here, the methods and equipment used are discussed in detail.

  19. Experimental evaluation of optimal Vehicle Dynamic Control based on the State Dependent Riccati Equation technique

    NARCIS (Netherlands)

    Alirezaei, M.; Kanarachos, S.A.; Scheepers, B.T.M.; Maurice, J.P.

    2013-01-01

    Development and experimentally evaluation of an optimal Vehicle Dynamic Control (VDC) strategy based on the State Dependent Riccati Equation (SDRE) control technique is presented. The proposed nonlinear controller is based on a nonlinear vehicle model with nonlinear tire characteristics. A novel

  20. Nuclear magnetic resonance apparatus

    International Nuclear Information System (INIS)

    Lambert, R.

    1991-01-01

    In order to include the effect of a magnetic object in a subject under investigation, Nuclear Magnetic Resonance (NMR) apparatus is operable at more than one radio frequency (RF) frequency. The apparatus allows normal practice as far as obtaining an NMR response or image from a given nuclear species is concerned, but, in addition, interrogates the nuclear spin system at a frequency which is different from the resonance frequency normally used for the given nuclear species, as determined from the applied magnetic field. The magnetic field close to a magnetised or magnetisable object is modified and the given nuclear species gives a response at the different frequency. Thus detection of a signal at the frequency indicates the presence of the chosen nuclei close to the magnetised or magnetisable object. Applications include validation of an object detection or automatic shape inspection system in the presence of magnetic impurities, and the detection of magnetic particles which affect measurement of liquid flow in a pipe. (author)

  1. Improvements in measuring apparatus

    International Nuclear Information System (INIS)

    Casey, W.

    1976-01-01

    Measuring apparatus is described that is suitable for gauging the wall profiles of downwardly extending channels in nuclear reactors, but which is equally applicable to channels such as pipe bores and conduits in other types of plant. The apparatus comprises a probe carrying a measuring transducer giving an electrical output. The probe support may be moved stepwise along the channel along a track between end members. An electrical conductor is provided for transmitting the electrical output of the transducer to an indicator located remote from the probe. The probe support may consist of a cable attached at one end to a winding drum, and incorporating an electrical conductor connected to the transducer. Channel engaging means are provided on the probe that permits free upward movement of the probe when the latter is suspended by the cable and moves into gripping engagement with the channel wall when the tension in the cable is relaxed. (U.K.)

  2. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoresis apparatus for clinical use. 862.2485 Section 862.2485 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An electrophoresis...

  3. 7 CFR 801.9 - Tolerances for test weight apparatuses.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerances for test weight apparatuses. 801.9 Section 801.9 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS... PERFORMANCE REQUIREMENTS FOR GRAIN INSPECTION EQUIPMENT § 801.9 Tolerances for test weight apparatuses. The...

  4. Apparatus for making molten silicon

    Science.gov (United States)

    Levin, Harry (Inventor)

    1988-01-01

    A reactor apparatus (10) adapted for continuously producing molten, solar grade purity elemental silicon by thermal reaction of a suitable precursor gas, such as silane (SiH.sub.4), is disclosed. The reactor apparatus (10) includes an elongated reactor body (32) having graphite or carbon walls which are heated to a temperature exceeding the melting temperature of silicon. The precursor gas enters the reactor body (32) through an efficiently cooled inlet tube assembly (22) and a relatively thin carbon or graphite septum (44). The septum (44), being in contact on one side with the cooled inlet (22) and the heated interior of the reactor (32) on the other side, provides a sharp temperature gradient for the precursor gas entering the reactor (32) and renders the operation of the inlet tube assembly (22) substantially free of clogging. The precursor gas flows in the reactor (32) in a substantially smooth, substantially axial manner. Liquid silicon formed in the initial stages of the thermal reaction reacts with the graphite or carbon walls to provide a silicon carbide coating on the walls. The silicon carbide coated reactor is highly adapted for prolonged use for production of highly pure solar grade silicon. Liquid silicon (20) produced in the reactor apparatus (10) may be used directly in a Czochralski or other crystal shaping equipment.

  5. Slit aperture technique for mammography

    International Nuclear Information System (INIS)

    Friedrich, M.

    1984-01-01

    Following a discussion of various principles used in the elimination of scatter, the prototype of a simple slit aperture mammography apparatus is described (modified Mammomat, Siemens). The main advantage of this technique compared with grid mammography is a halving of the radiation dose for identical image quality, using an identical film system. The technical requirements (heavy duty tube, new generator) are, however, considerable. If the film-screen systems currently in use are to remain the common systems for the future, then the development of a multi-lamellar slit diaphragm technique carries much promise for mammography. (orig.) [de

  6. Steady-state operation of spheromaks by inductive techniques

    International Nuclear Information System (INIS)

    Janos, A.

    1984-04-01

    A method to maintain a steady-state spheromak configuration inductively using the S-1 Spheromak device is described. The S-1 Spheromak formation apparatus can be utilized to inject magnetic helicity continuously (C.W., not pulsed or D.C.) into the spheromak configuration after equilibrium is achieved in the linked mode of operation. Oscillation of both poloidal- and toroidal-field currents in the flux core (psi-phi Pumping), with proper phasing, injects a net time-averaged helicity into the plasma. Steady-state maintenance relies on flux conversion, which has been earlier identified. Relevant experimental data from the operation of S-1 are described. Helicity flow has been measured and the proposed injection scheme simulated. In a reasonable time practical voltages and frequencies can inject an amount of helicity comparable to that in the initial plasma. Plasma currents can be maintained or increased. This pumping technique is similar to F-THETA Pumping of a Reversed-Field-Pinch but is applied to this inverse-pinch formation

  7. Biofilms and mechanics: a review of experimental techniques and findings

    International Nuclear Information System (INIS)

    Gordon, Vernita D; Davis-Fields, Megan; Kovach, Kristin; Rodesney, Christopher A

    2017-01-01

    Biofilms are developmentally-dynamic communities of sessile microbes that adhere to each other and, often, to other structures in their environment. The cohesive mechanical forces binding microbes to each other confer mechanical and structural stability on the biofilm and give rise to biofilm viscoelasticity. The adhesive mechanical forces binding microbes to other structures in their environment can promote biofilm initiation and mechanosensing that leads to changes in biological activity. Thus, physical mechanics is intrinsic to characteristics that distinguish biofilms from free-swimming or free-floating microbes in liquid culture. However, very little is known about the specifics of what mechanical traits characterize different types of biofilms at different stages of development. Even less is known about how mechanical inputs impact microbial biology and how microbes can adjust their mechanical coupling to, and interaction with, their environment. These knowledge gaps arise, in part, from the challenges associated with experimental measurements of microbial and biofilm biomechanics. Here, we review extant experimental techniques and their most-salient findings to date. At the end of this review we indicate areas where significant advances in the state-of-the art are heading. (topical review)

  8. Biofilms and mechanics: a review of experimental techniques and findings

    Science.gov (United States)

    Gordon, Vernita D.; Davis-Fields, Megan; Kovach, Kristin; Rodesney, Christopher A.

    2017-06-01

    Biofilms are developmentally-dynamic communities of sessile microbes that adhere to each other and, often, to other structures in their environment. The cohesive mechanical forces binding microbes to each other confer mechanical and structural stability on the biofilm and give rise to biofilm viscoelasticity. The adhesive mechanical forces binding microbes to other structures in their environment can promote biofilm initiation and mechanosensing that leads to changes in biological activity. Thus, physical mechanics is intrinsic to characteristics that distinguish biofilms from free-swimming or free-floating microbes in liquid culture. However, very little is known about the specifics of what mechanical traits characterize different types of biofilms at different stages of development. Even less is known about how mechanical inputs impact microbial biology and how microbes can adjust their mechanical coupling to, and interaction with, their environment. These knowledge gaps arise, in part, from the challenges associated with experimental measurements of microbial and biofilm biomechanics. Here, we review extant experimental techniques and their most-salient findings to date. At the end of this review we indicate areas where significant advances in the state-of-the art are heading.

  9. INFLATE: INFlate Landing Apparatus Technology

    Science.gov (United States)

    Koryanov, V. V. K.; Da-Poian, V. D. P.

    2018-02-01

    Our project, named INFLATE (INFlatable Landing Apparatus Technology), aims at reducing space landing risks and constraints and so optimizing space missions (reducing cost, mass, and risk and in the same time improving performance).

  10. Laser-welded ureteral anastomoses: experimental studies with three techniques.

    Science.gov (United States)

    Gürpinar, T; Gürer, S; Kattan, M W; Wang, L; Griffith, D P

    1996-01-01

    Tissue welding with laser energy is a new technique for reconstructive surgery. The potential advantages of laser welding are (a) lack of foreign body reaction, (b) decreased operative time, (c) less tissue manipulation, and (d) effective union of tissues equivalent to sutured anastomoses. We have performed ureteral anastomoses in adult mongrel dogs using a KTP 532 nm laser at an intensity of 1.4 W. Multiple "spot welds" of 1-s duration were utilized in a single layer anastomosis. Laser-welded anastomoses were performed with and without protein solder (33% and 50% human albumin) and were compared to sutured anastomoses. The laser-welded anastomoses required less operative time and provided bursting pressure levels similar to those of traditional sutured anastomoses. There was no advantage or disadvantage to the addition of human albumin as a solder in these experimental studies.

  11. Experimental nonlocal steering of Bohmian trajectories.

    Science.gov (United States)

    Xiao, Ya; Kedem, Yaron; Xu, Jin-Shi; Li, Chuan-Feng; Guo, Guang-Can

    2017-06-26

    Interpretations of quantum mechanics (QM), or proposals for underlying theories, that attempt to present a definite realist picture, such as Bohmian mechanics, require strong non-local effects. Naively, these effects would violate causality and contradict special relativity. However if the theory agrees with QM the violation cannot be observed directly. Here, we demonstrate experimentally such an effect: we steer the velocity and trajectory of a Bohmian particle using a remote measurement. We use a pair of photons and entangle the spatial transverse position of one with the polarization of the other. The first photon is sent to a double-slit-like apparatus, where its trajectory is measured using the technique of Weak Measurements. The other photon is projected to a linear polarization state. The choice of polarization state, and the result, steer the first photon in the most intuitive sense of the word. The effect is indeed shown to be dramatic, while being easy to visualize. We discuss its strength and what are the conditions for it to occur.

  12. Purification by using the zone melting technique; Purification par la technique de la zone fondue

    Energy Technology Data Exchange (ETDEWEB)

    Clerc, Michel

    1962-06-22

    The zone melting technique has first been used in metallurgy, and has been developed for the preparation of silicon and germanium for semiconductors, and then for the preparation of organic bodies of high purity. In this research thesis, the author first presents the principle of this technique, and then discusses the influence of agitation in liquid phase, and the influence of the number of passages over the zone. He discusses issues related to matter transport, and some technical details which intervene in the design of an apparatus for purification by zone melting. He finally presents examples.

  13. Mechanical properties of mammalian single smooth muscle cells. II. Evaluation of a modified technique for attachment of cells to the measurement apparatus

    NARCIS (Netherlands)

    J.J. Glerum (Jacobus); R. van Mastrigt (Ron)

    1990-01-01

    textabstractA method is described for attaching isolated single smooth muscle cells to an apparatus designed for measuring the longitudinal forces developed passively and actively by the cell upon straining, electrical or pharmacological stimulation. Primary attachment of the cell is based on its

  14. Apparatus for enrichment of uranium by double photoionization

    International Nuclear Information System (INIS)

    Laude, J.P.

    1983-11-01

    The present invention concerns enrichment of uranium by double photoionization. The use of a beam from a dye laser for excitation of gaseous uranium is known and the present invention concerns an apparatus of this type. The purpose of the invention is essentially to produce an apparatus having high energy efficiency. This is achieved according to the invention by using a continuous wave laser

  15. Apparatus for controlling molten core debris

    International Nuclear Information System (INIS)

    Golden, M.P.; Tilbrook, R.W.; Heylmun, N.F.

    1972-01-01

    Disclosed is an apparatus for containing, cooling, diluting, dispersing and maintaining subcritical the molten core debris assumed to melt through the bottom of a nuclear reactor pressure vessel in the unlikely event of a core meltdown. The apparatus is basically a sacrificial bed system which includes an inverted conical funnel, a core debris receptacle including a spherical dome, a spherically layered bed of primarily magnesia bricks, a cooling system of zig-zag piping in graphite blocks about and below the bed and a cylindrical liner surrounding the graphite blocks including a steel shell surrounded by firebrick. Tantalum absorber rods are used in the receptacle and bed. 9 claims, 22 figures

  16. Method and apparatus for combinatorial chemistry

    Science.gov (United States)

    Foote, Robert S [Oak Ridge, TN

    2012-06-05

    A method and apparatus are provided for performing light-directed reactions in spatially addressable channels within a plurality of channels. One aspect of the invention employs photoactivatable reagents in solutions disposed into spatially addressable flow streams to control the parallel synthesis of molecules immobilized within the channels. The reagents may be photoactivated within a subset of channels at the site of immobilized substrate molecules or at a light-addressable site upstream from the substrate molecules. The method and apparatus of the invention find particularly utility in the synthesis of biopolymer arrays, e.g., oligonucleotides, peptides and carbohydrates, and in the combinatorial synthesis of small molecule arrays for drug discovery.

  17. Development of a three-dimensional PIV measurement technique for the experimental study of air bubble collapse phenomena

    International Nuclear Information System (INIS)

    Yang, Y.H.; Hassan, Y.A.; Schmidl, W.D.

    1995-01-01

    Particle image velocimetry (PIV) is a quantitative flow measurement technique. The objective of this study is to develop a new three-dimensional PIV technique for the experimental study of air bubble collapse phenomena. A three-dimensional measurement technique is necessary since bubble collapse is a three-dimensional phenomenon. The investigation of the velocity flow field around a collapsing air bubble can provide detailed three-dimensional quantitative information to help improve the understanding of the related heat transfer processes

  18. Apparatus Producing an Even Distribution of Strain into Carries

    Science.gov (United States)

    Hrabovský, Leopold

    2017-10-01

    In many high-rise residential buildings or multi-storey warehouses, machinery, so called lifts, is used for the vertical transportation of people or weights between two or more altitudinally distant places. Carriers used for lifts are steel ropes or sprocket chains, on which a cage or a counterbalance is hinged. Apparatus of all carriers, attached to the hinge of the cage or counterbalance, should be even. This can be made only by hammer hinge. Fixed or springe hinge cannot be a perfect equalizing apparatus. This article describes an apparatus, which allows an even distribution of the strain into lift carriers, which use springe hinge of carrier ropes.

  19. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  20. Establishment of experimental equipments in irradiation technology development building

    International Nuclear Information System (INIS)

    Ishida, Takuya; Tanimoto, Masataka; Shibata, Akira; Kitagishi, Shigeru; Saito, Takashi; Ohmi, Masao; Nakamura, Jinichi; Tsuchiya, Kunihiko

    2011-06-01

    The Neutron Irradiation and Testing Reactor Center has developed new irradiation technologies to provide irradiation data with high technical value for the resume of the Japan Materials Testing Reactor (JMTR). For the purpose to perform assembling of capsules, materials tests, materials inspection and analysis of irradiation specimens for the development of irradiation capsules, improvement and maintenance of facilities were performed. From the viewpoint of effective use of existing buildings in the Oarai research and development center, the RI application development building was refurbished and maintained for above-mentioned purpose. The RI application development building is a released controlled area, and was used as storage of experimental equipments and stationeries. The building was named 'Irradiation Technology Development Building' after it refurbished and maintained. Eight laboratories were maintained based on the purpose of use, and the installation of the experimental apparatuses was started. A basic management procedure of the Irradiation Technology Development Building was established and has been operated. This report describes the refurbish work of the RI application development building, the installation and operation method of the experimental apparatuses and the basic management procedure of the Irradiation Technology Development Building. (author)

  1. Positioning and locking apparatus

    Science.gov (United States)

    Hayward, M.L.; Harper, W.H.

    1985-06-19

    A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.

  2. Participation and Neutrality of State Civil Apparatus in Direct Regional Election: Surabaya City Case

    Directory of Open Access Journals (Sweden)

    Catur Wibowo Budi Santoso

    2016-05-01

    Full Text Available In relation to the existence of State Civil Apparatus, at least there are two issues that must be observed in the implementation of Regional elections, namely the issues of participation and neutrality of State Civil Apparatus. The phenomenon that occurs during this time is the involvement of the State Civil Apparatus in attendance is still minimum (low. Moreover, it is believed that there are many Civil Apparatus State who is not neutral in the organization of Regional Elections. In this regard, this study aims to analyze the participation and neutrality of State Civil Apparatus. The method utilized in this study is qualitative. The result of the study shows that in general the participation of State Civil Apparatus in Surabaya is adequately good, but the neutrality of State Civil Apparatus has not implemented well enough. There are at least three (3 main factors influencing the participation of Civil State Apparatus, namely the factors of leadership exemplary, commitment to employees, and employee development. As for the neutrality of the State Civil Apparatus, among others, is influenced by the factors of the ambition of employee, primordialism, and working environment of employees.

  3. Glass enamel and glass-ceramic coatings for chemical apparatus

    International Nuclear Information System (INIS)

    Es'kov, A.S.; Oleinik, M.I.; Shabrova, E.A.

    1984-01-01

    Among the known anticorrosion coatings used in chemical engineering, glass enamel base coatings are distinguished by such advantages as a high degree of continuity and chemical resistance. The paper describes basic principles for the creation of acid and alkali resistant glass enamel and ceramic coatings for chemical apparatus. As the result of investgations, glass enamel coatings with increased electrical conductivity and also experimental production compositions of chemical, temperature and radiation resistant coatings for protection of chemical equipment of 12Kh18N10T stainless steel have been developed. The coatings have successfully passed testing under service conditions. A new type of coating is short-term glass enamel, which may be recommended for use in chemical machinery manufacturing and other branches of industry in oxidation-free heating and forming of stainless steels

  4. Apparatus as Milestones in the History of Comparative Psychology

    Science.gov (United States)

    Washburn, David A.; Rumbaugh, Duane M.; Putney, R. Thompson

    1994-01-01

    Significant apparatus developments from the history of comparative psychology are reviewed, including the contemporary trend toward computer use in research with nonhuman animals. It is argued that milestone apparatus served not only to open new lines of inquiry but also to shape or delimit the nature of the answers that were obtained.

  5. A Flexible Online Apparatus for Projectile Launch Experiments

    Directory of Open Access Journals (Sweden)

    Carlos Manuel Paiva

    2013-01-01

    Full Text Available In order to provide a more flexible learning environment in physics, the developed projectile launch apparatus enables students to determine the acceleration of gravity and the dependence of a set of parameters in the projectile movement. This apparatus is remotely operated and accessed via web, by first scheduling an access time slot. This machine has a number of configuration parameters that support different learning scenarios with different complexities.

  6. Self contained compressed air breathing apparatus to facilitate personnel decontamination

    International Nuclear Information System (INIS)

    McDonald, C.W.

    1963-11-01

    This report describes the modification of a Self Contained Compressed Air Breathing Apparatus to provide extended respiratory protection to grossly contaminated personnel during a decontamination period which may exceed the duration of the Breathing Apparatus air supply. (author)

  7. Self contained compressed air breathing apparatus to facilitate personnel decontamination

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, C W [Radiological and Safety Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-11-15

    This report describes the modification of a Self Contained Compressed Air Breathing Apparatus to provide extended respiratory protection to grossly contaminated personnel during a decontamination period which may exceed the duration of the Breathing Apparatus air supply. (author)

  8. THE DEVELOPMENT OF REGIONAL EXPANSION APPARATUS RESOURCE PLACEMENT IN INDONESIA

    Directory of Open Access Journals (Sweden)

    Suraji

    2018-02-01

    Full Text Available This study aimed to describe, analyze and deeply assess the implementation of regional apparatus resource development into new areas of regional expansion in Indonesia. The research was conducted by using qualitative approach, specifically, case study by analyzing descriptive data in the form of interviews, as well as analyzing valid data documentation to support the research problem. This research was conducted in the new area of Pangandaran Regency of West Java, Indonesia. The results of the research could map that there were still very few development programs of regional and apparatus expansion and it had not become the priority program after the expansion; the target of improving the quality of the apparatus resource appeared not to be the main measure, but rather, the main measure was the structuring of the apparatus and the issue of the regional office infrastructure; the instruments used in the development and training process were also less supportive, it caused many stagnant employees did not understand about new issues in the dynamics of work; apparatus development through training activities and scientific forums (seminars, scientific discussions, workshops and improvements was obstructed due to budget constraints.

  9. Thermal treatment of starch slurry in Couette-Taylor flow apparatus

    Directory of Open Access Journals (Sweden)

    Hubacz Robert

    2017-09-01

    Full Text Available In this paper, thermal processing of starch slurry in a Couette-Taylor flow (CTF apparatus was investigated. Gelatinized starch dispersion, after treatment in the CTF apparatus, was characterized using such parameters like starch granule diameters (or average diameter, starch granule swelling degree (quantifying the amount of water absorbed by starch granules and concentration of dissolved starch. These parameters were affected mostly by the process temperature, although the impact of the axial flow or rotor rotation on them was also observed. Moreover, the analysis of results showed a relatively good correlation between these parameters, as well as, between those parameter and apparent viscosity of gelatinized starch dispersion. Meanwhile, the increase in the value of the apparent viscosity and in shear-tinning behaviour of dispersion was associated with the progress of starch processing in the CTF apparatus. Finally, the CTF apparatuses of different geometries were compared using numerical simulation of the process. The results of the simulation indicated that the apparatus scaling-up without increasing the width of the gap between cylinders results in higher mechanical energy consumption per unit of processed starch slurry.

  10. UJI KONDUKTIVITAS TERMAL PADA DAUN BAYAM DENGAN MENGGUNAKAN THERMAL CONDUCTIVITY APPARATUS

    OpenAIRE

    Firmansyah, Firmansyah; Syafutra, Heriyanto; Sidikrubadi, Sidikrubadi; Irzaman, Irzaman

    2017-01-01

    Abstract Has successfully tested thermal conductivity on spinach leaves by using Thermal Conductivity Apparatus. Thermal conductivity Apparatus assisted with Steam generator, Caliper, Micrometer, and iron. The thermal conductivity value of spinach leaves is 0.5208 watts / (m.K). This thermal conductivity test on foliage, fruits using Thermal Conductivity Apparatus are very easy to do in Basic Physics Laboratory by physics study program students in Indonesia. Keywords: Thermal Conductivi...

  11. An Under-the-Table Leg-Movement Apparatus and Changes in Energy Expenditure

    Directory of Open Access Journals (Sweden)

    Gabriel A. Koepp

    2017-05-01

    Full Text Available Introduction: Deskwork contributes substantially to sedentariness. Here, we evaluated an under-the-table apparatus that was designed to promote leg movement (fidgeting while seated. Our hypothesis was that the under-the-table apparatus would increase energy expenditure.Methods: We measured energy expenditure and heart rate in 26 people while they sat and worked using a standard chair, walked on a treadmill, and sat and worked using an under-the-desk apparatus that encouraged leg movement.Results: Energy expenditure increased significantly while using the under-the-table apparatus when compared to the standard office chair (standard chair, 81 ± 18 kcal/h; under-the-table apparatus, 96 ± 23 kcal/h (P < 0.001; representing an 18 ± 16% increase. The changes in energy expenditure were not as great as walking (1 mph, 168 ± 46 kcal/h, P < 0.001; 2 mph, 205 ± 51 kcal/, P < 0.001, representing 107 ± 37% and 155 ± 48% increases over baseline, respectively.Conclusions: An under-the-table apparatus that promotes leg movement can increase energy expenditure by approximately 20%. Dynamic sitting is promoted by this apparatus and may be among a lexicon of options to help people move more while seated at work.

  12. Bone densitometry by gamma ray attenuation measurement. Development of an apparatus for use on medullary casualties

    International Nuclear Information System (INIS)

    Berard, E.J.-J.

    1975-01-01

    We proposed to follow changes in the bone mineral content of medullary damage cases by measuring the attenuation of a monoenergetic gamma ray according to the Cameron and Sorenson technique. Apart from their high cost, existing instruments are not designed for this bedside observation of patients. Our aim was therefore to design and develop an easily portable, inexpensive apparatus. The γ radiation is supplied by a sealed 125 I source fitted with a narrow collimator. The battery-operated scintillation detector is that used to detect post-operative phlebites after injection of radio-fibrinogen. The source-detector unit can move to allow a transverse bone mineral content measurement. Data from the detector are processed electronically and the results given: - either graphically on a tracing board which gives an area proportional to the bone mineral content, - or numerically by means of an integrator computing this area and supplying the linear bone density directly. Experiments carried out in vivo showed the apparatus to be sensitive and the measurements reproducible, the results obtained being comparable with those of other authors. Using pieces of embalmed bone moreover an excellent correlation was observed between the bone mineral content obtained after incineration and the results displayed by our apparatus, which can therefore be calibrated [fr

  13. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  14. X-ray examination apparatus

    NARCIS (Netherlands)

    2000-01-01

    The invention relates to an X-ray apparatus which includes an adjustable X-ray filter. In order to adjust an intensity profile of the X-ray beam, an X-ray absorbing liquid is transported to filter elements of the X-ray filter. Such transport is susceptible to gravitational forces which lead to an

  15. Construction of an experimental simplified model for determining of flow parameters in chemical reactors, using nuclear techniques

    International Nuclear Information System (INIS)

    Araujo Paiva, J.A. de.

    1981-03-01

    The development of a simplified experimental model for investigation of nuclear techniques to determine the solid phase parameters in gas-solid flows is presented. A method for the measurement of the solid phase residence time inside a chemical reactor of the type utilised in the cracking process of catalytic fluids is described. An appropriate radioactive labelling technique of the solid phase and the construction of an eletronic timing circuit were the principal stages in the definition of measurement technique. (Author) [pt

  16. Apparatus for extracting and sequestering carbon dioxide

    Science.gov (United States)

    Rau, Gregory H [Castro Valley, CA; Caldeira, Kenneth G [Livermore, CA

    2010-02-02

    An apparatus and method associated therewith to extract and sequester carbon dioxide (CO.sub.2) from a stream or volume of gas wherein said apparatus hydrates CO.sub.2 and reacts the resulting carbonic acid with carbonate. Suitable carbonates include, but are not limited to, carbonates of alkali metals and alkaline earth metals, preferably carbonates of calcium and magnesium. Waste products are metal cations and bicarbonate in solution or dehydrated metal salts, which when disposed of in a large body of water provide an effective way of sequestering CO.sub.2 from a gaseous environment.

  17. Realtime radiation exposure monitor and control apparatus

    International Nuclear Information System (INIS)

    Cowart, R.W.

    1981-01-01

    This patent application relates to an apparatus and methods used to obtain image information from modulation of a uniform flux. An exposure measuring apparatus is disclosed which comprises a multilayered detector structure having an external circuit connected to a transparent insulating layer and to a conductive plate a radiation source adapted to irradiate the detector structure with radiation capable of producing electron-hole pairs in a photoconductive layer of the detector wherein the flow of current within the external circuit is measured when the detector is irradiated by the radiation source. (author)

  18. Apparatus and process for controlling fluidized beds

    Science.gov (United States)

    Rehmat, Amirali G.; Patel, Jitendra G.

    1985-10-01

    An apparatus and process for control and maintenance of fluidized beds under non-steady state conditions. An ash removal conduit is provided for removing solid particulates from a fluidized bed separate from an ash discharge conduit in the lower portion of the grate supporting such a bed. The apparatus and process of this invention is particularly suitable for use in ash agglomerating fluidized beds and provides control of the fluidized bed before ash agglomeration is initiated and during upset conditions resulting in stable, sinter-free fluidized bed maintenance.

  19. Novel apparatus and methods for performing remotely controlled particle-solid interaction experiments at CERN

    Science.gov (United States)

    Krause, H. F.; Deveney, E. F.; Jones, N. L.; Vane, C. R.; Datz, S.; Knudsen, H.; Grafström, P.; Schuch, R.

    1997-04-01

    Recent atomic physics studies involving ultrarelativistic Pb ions required solid target positioners, scintillators, and a sophisticated data acquisition and control system placed in a remote location at the CERN Super Proton Synchrotron near Geneva, Switzerland. The apparatus, installed in a high-radiation zone underground, had to (i) function for months, (ii) automatically respond to failures such as power outages and particle-induced computer upsets, and (iii) communicate with the outside world via a telephone line. The heart of the apparatus developed was an Apple Macintosh-based CAMAC system that answered the telephone and interpreted and executed remote control commands that (i) sensed and set targets, (ii) controlled voltages and discriminator levels for scintillators, (iii) modified data acquisition hardware logic, (iv) reported control information, and (v) automatically synchronized data acquisition to the CERN spill cycle via a modem signal and transmitted experimental data to a remote computer. No problems were experienced using intercontinental telephone connections at 1200 baud. Our successful "virtual laboratory" approach that uses off-the-shelf electronics is generally adaptable to more conventional bench-type experiments.

  20. Development of channel inspection and gauging apparatus for 235 MWe PHWRs

    International Nuclear Information System (INIS)

    Parulkar, S.K.; Taneja, R.; Taliyan, S.S.; Singh, Manjit; Govindarajan, G.

    1992-01-01

    Channel inspection and gauging apparatus is being developed to enable in-service channel inspection and gauging. Phase I apparatus to measure annular gap between pressure tube and calandria tube in a dry channel has been developed. The apparatus consists of a gauging head and a drive mechanism. The gauging head utilities an eddy current probe to measure the annular gap between pressure tube and calandria tube and an ultrasonic sensor to measure the wall thickness of the pressure tube. The output signal of the eddy current probe needs to be corrected for the effect of pressure tube wall thickness variation. This paper gives the details of the above apparatus. The results of calibration tests at mock-up station are presented. The paper outlines the program for the phase-wise development of Channel Inspection and Gauging Apparatus for use in heavy water filled channels without their isolation from PHT and draining. The final apparatus will have the facilities for ultrasonic flaw detection, ultrasonic gauging to measure pressure tube diameter and wall thickness, an inclinometer to measure slope and sag of pressure tube and eddy current probe for the measurement of annular gap between pressure tube and calandria tube. (author). 6 figs

  1. Apparatus for the laser ablative synthesis of carbon nanotubes

    Science.gov (United States)

    Smith, Michael W.; Jordan, Kevin

    2010-02-16

    An RF-induction heated side-pumped synthesis chamber for the production of carbon nanotubes. Such an apparatus, while capable of producing large volumes of carbon nanotubes, concurrently provides a simplified apparatus that allows for greatly reduced heat up and cool down times and flexible flowpaths that can be readily modified for production efficiency optimization.

  2. Experimental investigation on 3D-SEM reconstructions of a wire gauge using stereo-pair technique

    DEFF Research Database (Denmark)

    Carli, Lorenzo; Genta, G.; Cantatore, Angela

    2011-01-01

    In this work an experimental investigation is addressed concerning 3D-SEM reconstructions obtained from the so-called stereo-pair technique. Three-dimensional topography of an object can be derived from two SEM images acquired from two different angles, through item rotation by means of the SEM...

  3. Tandem mirror plasma confinement apparatus

    Science.gov (United States)

    Fowler, T. Kenneth

    1978-11-14

    Apparatus and method for confining a plasma in a center mirror cell by use of two end mirror cells as positively charged end stoppers to minimize leakage of positive particles from the ends of the center mirror cell.

  4. PNO-apparatus and its test use for neutron interferometry

    International Nuclear Information System (INIS)

    Tomimitsu, Hiroshi; Aizawa, Kazuya; Hasegawa, Yuji; Kikuta, Seishi.

    1993-01-01

    Special apparatus 'PNO' of multiutility in the so-called precise neutron optics, such as double or triple crystal diffractometry, interferometry, etc., including neutron diffraction topography, was settled at 3G beam hole in the JRR-3M. In the symposium, several applications of the PNO apparatus are presented as 1) very small angle neutron scattering tool with double crystal arrangement, 2) the characterization of the quality of artificial multilayer lattices made of Ti-Ni by a triple crystal arrangement, 3) the characterization of Ni-base superalloy single crystals by the diffraction topography, which are presented in individual sessions. Preliminary test of the neutron interferometry was also tried with the PNO apparatus. Usual monolithic Si LLL- type interferometer was used with an Al phase shifter in the neutron beam paths. The periodicity of the measured intensity curve was well corresponded to the expected one. The best contrast of the intensity curve was measured as high as 43%. The utility of the PNO-apparatus for neutron interferometry was, thus, approved. (author)

  5. Variable frequency microwave heating apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Bible, D.W.; Lauf, R.J.; Johnson, A.C.; Thigpen, L.T.

    1999-10-05

    A variable frequency microwave heating apparatus (10) designed to allow modulation of the frequency of the microwaves introduced into a multi-mode microwave cavity (34) for testing or other selected applications. The variable frequency microwave heating apparatus (10) includes a microwave signal generator (12) and a high-power microwave amplifier (20) or a high-power microwave oscillator (14). A power supply (22) is provided for operation of the high-power microwave oscillator (14) or microwave amplifier (20). A directional coupler (24) is provided for detecting the direction and amplitude of signals incident upon and reflected from the microwave cavity (34). A first power meter (30) is provided for measuring the power delivered to the microwave furnace (32). A second power meter (26) detects the magnitude of reflected power. Reflected power is dissipated in the reflected power load (28).

  6. A steam separator-superheater apparatus

    International Nuclear Information System (INIS)

    Androw, Jean; Bessouat, Roger; Peyrelongue, J.-P.

    1973-01-01

    Description is given of a separator-superheater apparatus comprising an outer enclosure containing a separating-unit and a steam superheating unit according to the main patent. The present addition relates to an improvement in that apparatus, characterized in that the separating unit and the superheating unit, mounted in two distinct portions of the outer enclosure, are divided into the same number of sub-units of each unit being identical and operating in parallel, and in that to each separator sub-unit is associated a superheater sub-unit, said sub-units being mounted in series and located in one in the other of the enclosure two portions, respectively. This can be applied to the treatment of the exhaust steam of a turbine high pressure body, prior to re-injecting said steam into the low pressure body [fr

  7. Evaluation of Baermann apparatus sedimentation time on recovery of Strongylus vulgaris and S. edentatus third stage larvae from equine coprocultures.

    Science.gov (United States)

    Bellaw, Jennifer L; Nielsen, Martin K

    2015-06-30

    Traditional methods of diagnosing equine Strongylinae infections require culturing feces, sedimenting the culture media in Baermann apparatuses, collecting the sediment, and morphologically identifying recovered third stage larvae. However, this method is plagued by low negative predictive values. This study evaluated sedimentation time within the Baermann apparatus by comparing larval recovery from the traditionally collected sediment, "sediment 1", and from the usually discarded remaining fluid contents, "sediment 2", of the Baermann apparatus after 12, 24, and 48 h. A grand total of 147,482 larvae were recovered and examined. Sedimentation time did not significantly influence total larval recovery. At all three durations, significantly more Cyathostominae and Strongylus vulgaris larvae were covered from sediment 1 than from sediment 2. However, less than 60% of all recovered Strongylus edentatus were recovered from sediment 1. As 95% of S. vulgaris larvae were always recovered from sediment 1, the need for collection and examination of the remaining fluid contents of the Baermann apparatus is obviated when performing coprocultures for diagnosis of S. vulgaris infections, and sedimentation for 12h is adequate. Approximately 70% of Cyathostominae were recovered in sediment 1 at all durations, suggesting that 12h of sedimentation is adequate, although there is a need for future research to evaluate the risk of selection bias at differing sedimentation times among individual cyathostomin species. In contrast to S. vulgaris, collecting and examining the entire contents of the Baermann apparatus may be necessary when an increased diagnostic sensitivity and negative predictive value is desired in diagnosing S. edentatus infections as only 38-61% of larvae were recovered from sediment 1 portion of the Baermann apparatus. This information will allow researchers and practitioners to make more informed decisions in choosing appropriate larval recovery techniques, balancing

  8. Rescue apparatus for a high working oil derrick

    Energy Technology Data Exchange (ETDEWEB)

    Prokopov, O.P.; Yagudin, S.Z.

    1980-05-18

    In order to improve reliability of the rescue apparatus a device for lowering a basket is made in the form of a collapsible forked support installed in the vertical plane inclined away from the tower. Its lower ends are attached by hinges to the base of the derrick. The upper end is connected to the derrick by means of a fastener. The apparatus has brakes with shock straps for receiving forked support.

  9. Simple and Low-Cost Exposed -Layer Grain Drying Apparatus ...

    African Journals Online (AJOL)

    Thin-layer drying apparatus was developed from standard “off-the- shelf” equipment: a fan convection laboratory oven and a weighing scale. Using this apparatus the thin-layer drying data for wheat under constant conditions were obtained for a range of drying air temperature from 30°C to 150°C and the initial moisture ...

  10. A new apparatus at hyper irradiation research facility at the Atomic Research Center, University of Tokyo

    International Nuclear Information System (INIS)

    Shibata, Hiromi; Iwai, Takeo; Narui, Makoto; Omata, Takao

    1996-01-01

    In the hyper irradiation research facility at the Atomic Research Center, the University of Tokyo, following apparatuses were newly installed for accelerator relating apparatus on 1995 fiscal year; 1) Hyper ion microbeam analysis apparatus, 2) Fourier conversion infrared microscopy, 3) Pico second two-dimensional fluorescence measuring apparatus, 4) Femto second wave-length reversible pulse laser radiation apparatus, and others. In addition to double irradiation, pulse beam irradiation experiment and so forth characteristic in conventional hyper irradiation research apparatus, upgrading of material irradiation experiments using these new apparatuses are intended. (G.K.)

  11. A new apparatus at hyper irradiation research facility at the Atomic Research Center, University of Tokyo

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Hiromi; Iwai, Takeo; Narui, Makoto; Omata, Takao [Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology

    1996-12-01

    In the hyper irradiation research facility at the Atomic Research Center, the University of Tokyo, following apparatuses were newly installed for accelerator relating apparatus on 1995 fiscal year; (1) Hyper ion microbeam analysis apparatus, (2) Fourier conversion infrared microscopy, (3) Pico second two-dimensional fluorescence measuring apparatus, (4) Femto second wave-length reversible pulse laser radiation apparatus, and others. In addition to double irradiation, pulse beam irradiation experiment and so forth characteristic in conventional hyper irradiation research apparatus, upgrading of material irradiation experiments using these new apparatuses are intended. (G.K.)

  12. Polarization Imaging Apparatus with Auto-Calibration

    Science.gov (United States)

    Zou, Yingyin Kevin (Inventor); Zhao, Hongzhi (Inventor); Chen, Qiushui (Inventor)

    2013-01-01

    A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5 deg, a second variable phase retarder with its optical axis aligned 45 deg, a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I(sub 0), I(sub 1), I(sub 2) and I(sub 3) of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (pi,0), (pi,pi) and (pi/2,pi), respectively. Then four Stokes components of a Stokes image, S(sub 0), S(sub 1), S(sub 2) and S(sub 3) were calculated using the four intensity images.

  13. Tandem mirror plasma confinement apparatus

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1978-01-01

    Apparatus and method are described for confining a plasma in a center mirror cell by use of two end mirror cells as positively charged end stoppers to minimize leakage of positive particles from the ends of the center mirror cell

  14. A New On-Line Detecting Apparatus of the Residual Chlorine in Disinfectant for Fresh-Cut Vegetables

    Science.gov (United States)

    Hu, Chao; Su, Shu-Qiang; Li, Bao-Guo; Liu, Meng-Fang

    With the fast development of modern food and beverage industry, fresh-cut vegetables have wider application than before. During the process of sterilization in fresh-cut vegetables, the concentration of chloric disinfectant is usually so high that the common sensor can't be used directly on the product line. In order to solve this problem, we have invented a new detecting apparatus which could detect high concentration of chloric disinfectant directly. In this paper, the working principle, main monitor indicators, application and technical creations of the on-line apparatus have been discussed, and we also carried on the experimental analysis for its performance. The actual demands in factory could be met when the detecting flux is 2L/min, the dilution ratio is 15 and input amount of the disinfectant is 200ml per time, the max of the detecting deviation achieves ±4.8ppm(mg/L). The main detecting range of residual chlorine is 0~300ppm.

  15. Development of human factors experimental evaluation techniques - Human factors design and evaluation of the main control room of atomic power plants using visual display terminals

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sung Ho; Chung, Min Kyun; Choi, Kyung Lim; Song, Young Woong; Eoh, Hong Joon; Lee, In Suk; Kim, Bom Soo; Yeo, Yun Shin; Lee, Haeo Sun [Pohang University of Science and Technology, Pohang (Korea, Republic of)

    1995-07-01

    This study was conducted to build a prototype of the operator interface on a visual display terminal, and to provide a framework for using and applying prototyping techniques. A typical subsystem of an MCR was prototyped and validated by operator testing. Lessons learned during the development as well as prototyping techniques were described in this report for an efficient development. In addition, human factors experimental plans were surveyed and summarized for evaluating new design alternatives as well as the current design of the operator interface. The major results of this study are listed as follow: A method for designing an operator interface prototype on a VDT, A prototype of the operator interface of a typical subsystem, Guidelines for applying prototyping techniques, Characteristics and major considerations of experimental plans, Guidelines for applying prototyping techniques, Characteristics and major considerations of experimental plans, Guidelines for analyzing experimental data, A paradigm for human factors experimentation including experimental designs, procedures, and data analyses. 27 refs., 60 tabs., 47 figs. (author)

  16. Automatic emissive probe apparatus for accurate plasma and vacuum space potential measurements

    Science.gov (United States)

    Jianquan, LI; Wenqi, LU; Jun, XU; Fei, GAO; Younian, WANG

    2018-02-01

    We have developed an automatic emissive probe apparatus based on the improved inflection point method of the emissive probe for accurate measurements of both plasma potential and vacuum space potential. The apparatus consists of a computer controlled data acquisition card, a working circuit composed by a biasing unit and a heating unit, as well as an emissive probe. With the set parameters of the probe scanning bias, the probe heating current and the fitting range, the apparatus can automatically execute the improved inflection point method and give the measured result. The validity of the automatic emissive probe apparatus is demonstrated in a test measurement of vacuum potential distribution between two parallel plates, showing an excellent accuracy of 0.1 V. Plasma potential was also measured, exhibiting high efficiency and convenient use of the apparatus for space potential measurements.

  17. Electron-impact ionization of SiCl{sub 3} using an improved crossed fast-neutral-beam - electron-beam apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, J M; Gutkin, M V; Tarnovsky, V; Becker, K [Department of Physics and Engineering Physics, Stevens Institute of Technology, Hoboken, NJ 07030 (United States)], E-mail: kbecker@poly.edu

    2008-05-15

    The fast-neutral-beam technique is a versatile approach to the determination of absolute cross sections for electron-impact ionization of atoms, stable molecules as well as free radicals and metastable species. A fast neutral beam of the species under study is prepared by charge-transfer neutralization of a mass-selected ion beam and the species are subsequently ionized by an electron beam. Mass- and energy-dispersive selection separates singly from multiply charged ions and parent from fragment ions and allows the determination of partial ionization cross sections. Here we describe some major improvements that were made recently to the fast-beam apparatus that has been used extensively for ionization cross section measurements for the past 15 years in our group. Experiments using well-established ionization cross sections in conjunction with extensive ion trajectory simulations were carried out to test the satisfactory performance of the modified fast-neutral-beam apparatus. We also report absolute partial cross sections for the formation of various singly charged positive ions produced by electron impact on SiCl{sub 3} for impact energies from threshold to 200 eV in the modified fast-beam apparatus.

  18. Apparatus for decomposing shale

    Energy Technology Data Exchange (ETDEWEB)

    Gislain, M

    1865-06-20

    The apparatus is designed to fulfill the three following conditions: (1) complete extraction of the mineral oil, by avoiding partial decomposition; (2) purification of the said oil from products formed in the decomposition of the shale; (3) breaking down of the said oil into more products of different density. The separation of the heavy and bituminous products is claimed.

  19. Handling apparatus for a nuclear reactor fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Hornak, L.P.; Desmarchais, W.E.

    1978-01-01

    An apparatus is disclosed for handling radioactive fuel assembly during transfer operations. The radioactive fuel assembly is drawn up into a shielding sleeve which substantially reduces the level of radioactivity immediately surrounding the sleeve thereby permitting direct access by operating personnel. The lifting assembly which draws the fuel assembly up within the shielding sleeve is mounted to and forms an integral part of the handling apparatus. The shielding sleeve accompanies the fuel assembly during all of the transfer operations

  20. Apparatus for treating carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Kumar, P.P.

    1984-01-01

    Disclosed is an apparatus for treating carcinoma of the uterine cervix by judiciously applying radioactive material immediately adjacent the uterine cervix for an extended period of time empirically determined by the radiologist. The novel apparatus comprises three radioactively chargeable components including a central tubular tandem vaginally insertable longitudinally into the uterine cervix and two non-lineal tubular ovoidal assemblies longitudinally locatable at the cervix and positioned laterally between the respective vaginal walls and the uterine cervix. The ovoidal assemblies are conveniently removably and pivotably connected to the central tandem component externally of the vaginal along the sagittal plane through a novel adapter member whereby the radioactively chargeable ovoidal assemblies tend to remain within a laterally extending plane located substantially midway the transversely separated vasicovaginal and rectovaginal septa, even though the patient periodically shifts her reclining posture during the extended treatment by said vaginally protruding apparatus