WorldWideScience

Sample records for existing mri equipment

  1. Philips 3T Intera Magnetic Resonance Imaging System and Upgrade of existing MRI equipment

    Energy Technology Data Exchange (ETDEWEB)

    Evanochko, William T

    2004-05-14

    The objective of this proposal was twofold. First, upgrade existing MRI equipment, specifically a research 4.1T whole-body system. Second, purchase a clinical, state-of-the-art 3T MRI system tailored specifically to cardiovascular and neurological applications. This project was within the guidelines of ''Medical Applications and Measurement Science''. The goals were: [1] to develop beneficial applications of magnetic resonance imaging; [2] discover new applications of MR strategies for medical research; and [2] apply them for clinical diagnosis. Much of this proposal searched for breakthroughs in this noninvasive and nondestructive imaging technology. Finally, this proposal's activities focused on research in the basic science of chemistry, biochemistry, physics, and engineering as applied to bioengineering. The centerpiece of this grant was our 4.1T ultra-high field whole-body nuclear magnetic resonance system and the newly acquired state-of-the-art, heart and head dedicated 3T clinical MRI system. We have successfully upgraded the equipment for the 4.1T system so that it is now state-of-the-art with new gradient and radio frequency amplifiers. We also purchase a unique In Vivo EKG monitoring unit that will permit tracking clinical quality EKG signals while the patient is in a high field MR scanner. Important upgrades of a peripheral vascular coil and a state-of-the-art clinical workstation for processing complex heart images were implemented. The most recent acquisition was the purchase of a state-of-the-art Philips 3T Intera clinical MRI system. This system is unique in that the magnet is only 5 1/2 feet long compare to over 12 feet long magnet of our 4.1T MRI system. The 3T MRI system is fully functional and its use and applications are already greatly benefiting the UAB with 200-300 micron resolution brain images and diagnostic quality MR angiography of coronary arteries in less than 5 minutes.

  2. COMPARISON OF THE COMPLETE FOURIER DIRECT MRI WITH EXISTING DIFFUSION WEIGHTED MRI METHODS

    OpenAIRE

    Özcan, Alpay

    2011-01-01

    The Complete Fourier Direct (CFD) MRI method introduced in earlier work for modeling the diffusion weighted MRI signal is compared with the existing methods. The preservation of Hermitian symmetry in the diffusion weighted MRI signal without affecting its energy is the key point that differentiates CFD–MRI from the existing methods. By keeping the correct Fourier relationship intact, the joint distribution function is represented ‘as it is’, without any constraints, e.g. being symmetric. The ...

  3. Shortcomings of existing equipment for automatic coke requenching

    Energy Technology Data Exchange (ETDEWEB)

    Shramenko, A.P. (UPO UVD, Donetsk (USSR))

    1989-02-01

    Discusses operation and reliability of equipment for reducing temperature of coke transported by belt conveyors. Operation of two systems, the ADK-3 and ADK developed on the basis of the APIR-S, is analyzed. The FR-13 photoconductor is a key element of the ADK-3. It detects sources of infrared radiation with wavelength from 1 to 3.2 mkm. The photoconductor is efficient for detecting coke with temperatures exceeding 300 C but its sensitivity is reduced when coke temparture ranges from 200 to 300 C. The ADK-3 continuously measures coke temperature 3 to 4 s long. In the case of hot coke zones more than 10 m long on a belt conveyor, the measuring intervals are too long and fire hazards occur as water sprays are closed before the end of a hot coke zone reaches the spraying system. Recommendations for design modifications of the ADK-3 system are discussed: optimum sensitivity, photoconductor cooling, dust control, use of amplifiers, optimum number of electroconductors and their arrangement. 8 refs.

  4. Geothermal-well completions: a survey and technical evaluation of existing equipment and needs

    Energy Technology Data Exchange (ETDEWEB)

    Nicholson, J.E.; Snyder, R.E.

    1982-07-01

    The geothermal environment and associated well completion problems are reviewed. Existing well completion equipment is surveyed and limitations are identified. A technical evaluation of selected completion equipment is presented. The technical evaluation concentrates on well cementing equipment and identifies potential failure mechanisms which limit the effectiveness of these tools. Equipment employed in sand control, perforating, and corrosion control are identified as potential subjects for future technical evaluation.

  5. Prospective motion correction for MRI using EEG-equipment

    DEFF Research Database (Denmark)

    Andersen, Mads; Madsen, Kristoffer Hougaard; Hanson, Lars G.

    2016-01-01

    A new prospective motion correction technique is presented that is based on signals from gradient switching, in an EEG-cap with interconnected electrodes the subject wears during scanning. The method has no line-of-sight limitations as optical methods, requires no interleaved navigator modules or...... or additional hardware for sites already doing EEG-fMRI. Instead a training scan is performed were signals recorded with the EEG-system are correlated with motion parameters estimated by image realignment. Initial results from application of the method in a phantom are promising....

  6. 77 FR 17099 - Proposed Extension of Existing Information Collection; Diesel-Powered Equipment for Underground...

    Science.gov (United States)

    2012-03-23

    ... Administration (MSHA) requires mine operators to provide important safety protections to underground coal miners... requirements; Sec. 75.1904(b)(4)(i)--Underground diesel fuel tanks and safety cans; Sec. 75.1906(d)--Transport... underground coal miners who work in mines that use diesel-powered equipment. Diesel equipment can pose a fire...

  7. MRI

    DEFF Research Database (Denmark)

    Schroeter, Aileen; Rudin, Markus; Gianolio, Eliana

    2017-01-01

    This chapter discusses principles of nuclear magnetic resonance (NMR) and MRI followed by a survey on the major classes of MRI contrast agents (CA), their modes of action, and some of the most significative applications. The two more established classes of MRI-CA are represented by paramagnetic...

  8. The development of equipment for the technical assessment of respiratory motion induced artefacts in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, P.C.; Davies, S.C.; Zananiri, F.V.; Follett, D.H.; Halliwell, M.; Wells, P.N.T. (Bristol General Hospital (United Kingdom)); Bean, J.P. (Imperial College of Science, Technology and Medicine, London (United Kingdom). Dept. of Electrical Engineering)

    1993-02-01

    A device and technique to study the effects of respiratory motion on the quality of magnetic resonance images is proposed. The construction of the device enables a variety of test objects to be mounted and used in the evaluation of imaging parameters that may be affected by motion. The equipment is constructed of cast acrylic and the movement is actuated and controlled pneumatically thus ensuring that there are no interactions with the magnetic field and radiofrequency detection system to cause further image artefacts. Separate studies have been performed, using ultrasound, to assess the degree and rate of movement of organs owing to respiration in order to derive the motion parameters for the apparatus. Preliminary results indicate that the technique produces motion induced artefacts simulating those which are the result of the effects of respiration. (author).

  9. MRI

    Science.gov (United States)

    ... and radio waves to create pictures of the body. It does not use radiation (x-rays). Single MRI images are called slices. The images can be stored on a computer or printed on film. One exam produces dozens or sometimes hundreds of ...

  10. High field MRI: safety and protection problems related to the installation and the management of a 4T equipment

    Energy Technology Data Exchange (ETDEWEB)

    Russo, A.; Speranza, A. [National Research Council, Institute of Bioimaging and Biostructures- Dep.of Biomorphological and Functional Sciences - University Federico II, Napoli (Italy); DELIA, R. [University of Rome - Medicine and Surgery Faculty - La Sapienza Sez. Rieti (Italy); ANTOLINI, R. [University of Trento - Department of Physics, Trento (Italy); FERRARI, P. [University of Trento - Direction of Polo di Rovereto, Trento (Italy); FILIPPI, M. [University of Trento Prevention and Protection Service, Trento (Italy)

    2006-07-01

    The Physics Department of Trento University (Italy), in collaboration with Bruker Biospin decided to set up a 4 T MR system for research in the neurological field as well as on the biological effects of high field MRI. Nowadays the number of similar apparatus set up in the world is very low, several of these operate in the USA, some in Australia and one in Israel. Due to the very low diffusion of these equipments and to the few knowledge today available about the biological effects by clinical application of high field MRI, the problems related to the installation of the apparatus from the safety point of view are not well standardized. Therefore, in Trento, it has been necessary to deal with many problems regarding the set up of the MRI apparatus, taking also into account the current law in Italy with respect the safety and protection in MRI applications. In the present paper the Authors show the carried out studies and analyses, in relation to the organization of the safety aspects. These studies have resulted in arranging specific guidelines for: working in controlled way; emergency procedures for the patient advanced life support; procedures for the protocol of patient protection; rules for the safety of the operators, patients and general public. The carried out analyses have mainly taken into account the danger identification and the risk evaluation. For this reason it was set up a test protocol regarding:the performing tests, the very detailed test modalities for their periodic performance and the test sequence. For the patient safety and protection it has been necessary to put care, in the first step of the survey, to the subjects in critical situations, due to: working activity, clinical history, health conditions of the patient at the moment of the examination. So it has been necessary to set up an anamnesis questionnaire for the patient, finalized to spot: (1) the patients with particular contraindications for the MR examination; (2) the patients which

  11. Field Guide for Testing Existing Photovoltaic Systems for Ground Faults and Installing Equipment to Mitigate Fire Hazards

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, William [Brooks Engineering, Vacaville, CA (United States); Basso, Thomas [National Renewable Energy Lab. (NREL), Golden, CO (United States); Coddington, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    Ground faults and arc faults are the two most common reasons for fires in photovoltaic (PV) arrays and methods exist that can mitigate the hazards. This report provides field procedures for testing PV arrays for ground faults, and for implementing high resolution ground fault and arc fault detectors in existing and new PV system designs.

  12. Development of the electromagnetic tomography system. Field test results using existing equipment; EM tomography system no kaihatsu. Kison sochi ni yoru test sokutei kekka

    Energy Technology Data Exchange (ETDEWEB)

    Kumekawa, Y.; Miura, Y.; Takasugi, S. [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Arai, E. [Metal Mining Agency of Japan, Tokyo (Japan)

    1996-05-01

    With the purpose of developing an electromagnetic tomography system, an observation was carried out with existing equipment combined, and the data was analyzed. The measuring equipment consisted of existing borehole vertical magnetic field sensors as the sensor part, MT method receivers as the receiving device, and existing CSMT method transmitters as the transmitting device. The measuring was performed at the Richmond Field Station which was abundant in existing data and which had a comparatively simple resistivity structure. The borehole vertical magnetic field sensors were lowered inside the borehole, and signal sources were arranged at 10m apart on the traverse line in the direction from northeast to southwest with the borehole as the center. The analysis of the data was made with the use of EM1D by three models, namely, 10 ohm{center_dot}m homogeneous earth model, 100 ohm{center_dot}m homogeneous earth model, and horizontal 7 layer model prepared on the basis of electric logging results; and a comparative examination was made against the measured data. As a result, it was demonstrated that the test measurement agreed very well with the model from the electric logging results and that it was the data reflecting a resistivity structure. 8 refs., 6 figs.

  13. How green can black be? Assessing the potential for equipping USA's existing coal fleet with carbon capture and storage

    Science.gov (United States)

    Patrizio, Piera; Leduc, Sylvain; Mesfun, Sennai; Yowargana, Ping; Kraxner, Florian

    2017-04-01

    The mitigation of adverse environmental impacts due to climate change requires the reduction of carbon dioxide emissions - also from the U.S. energy sector, a dominant source of greenhouse-gas emissions. This is especially true for the existing fleet of coal-fired power plants, accounting for roughly two-thirds of the U.S. energy sectors' total CO2 emissions. With this aim, different carbon mitigation options have been proposed in literature, such as increasing the energy efficiency, co-firing of biomass and/or the adoption of carbon capturing technologies (BECCS). However, the extent to which these solutions can be adopted depends on a suite of site specific factors and therefore needs to be evaluated on a site-specific basis. We propose a spatially explicit approach to identify candidate coal plants for which carbon capture technologies are economically feasible, according to different economic and policy frameworks. The methodology implies the adoption of IIASA's techno economic model BeWhere, which optimizes the cost of the entire BECCS supply chain, from the biomass resources to the storage of the CO2 in the nearest geological sink. The results shows that biomass co-firing appears to be the most appealing economic solution for a larger part of the existing U.S. coal fleet, while the adoption of CCS technologies is highly dependent on the level of CO2 prices as well as on local factors such as the type of coal firing technology and proximity of storage sites.

  14. Assessment of released heavy metals from electrical and electronic equipment (EEE) existing in shipwrecks through laboratory-scale simulation reactor.

    Science.gov (United States)

    Hahladakis, John N; Stylianos, Michailakis; Gidarakos, Evangelos

    2013-04-15

    In a passenger ship, the existence of EEE is obvious. In time, under shipwreck's conditions, all these materials will undergo an accelerated severe corrosion, due to salt water, releasing, consequently, heavy metals and other hazardous substances in the aquatic environment. In this study, a laboratory-scale reactor was manufactured in order to simulate the conditions under which the "Sea Diamond" shipwreck lies (14 bars of pressure and 16°C of temperature) and remotely observe and assess any heavy metal release that would occur, from part of the EEE present in the ship, into the sea. Ten metals were examined and the results showed that zinc, mercury and copper were abundant in the water samples taken from the reactor and in significantly higher concentrations compared to the US EPA CMC (criterion maximum concentration) criterion. Moreover, nickel and lead were found in concentrations higher than the CCC (criterion constant concentration) criterion set by the US EPA for clean seawater. The rest of the elements were measured in concentrations within the permissible limits. It is therefore of environmental benefit to salvage the wreck and recycle all the WEEE found in it. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Assessment of released heavy metals from electrical and electronic equipment (EEE) existing in shipwrecks through laboratory-scale simulation reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hahladakis, John N., E-mail: john_chach@yahoo.gr [Department of Environmental Engineering, Technical University of Crete, Politechnioupolis, Chania 73100 (Greece); Stylianos, Michailakis [Department of Environmental Engineering, Technical University of Crete, Politechnioupolis, Chania 73100 (Greece); Gidarakos, Evangelos, E-mail: gidarako@mred.tuc.gr [Department of Environmental Engineering, Technical University of Crete, Politechnioupolis, Chania 73100 (Greece)

    2013-04-15

    Highlights: ► A laboratory-scale reactor was built to simulate the “Sea Diamond” shipwreck. ► EEE was thrown into the reactor for heavy metal release rate assessment. ► 15 seawater samples were taken and analyzed in a nine month experimental period. ► Zinc, mercury and copper were found in concentrations above the CMC criterion. ► Nickel and lead were found in concentrations higher than the CCC criterion. -- Abstract: In a passenger ship, the existence of EEE is obvious. In time, under shipwreck's conditions, all these materials will undergo an accelerated severe corrosion, due to salt water, releasing, consequently, heavy metals and other hazardous substances in the aquatic environment. In this study, a laboratory-scale reactor was manufactured in order to simulate the conditions under which the “Sea Diamond” shipwreck lies (14 bars of pressure and 16 °C of temperature) and remotely observe and assess any heavy metal release that would occur, from part of the EEE present in the ship, into the sea. Ten metals were examined and the results showed that zinc, mercury and copper were abundant in the water samples taken from the reactor and in significantly higher concentrations compared to the US EPA CMC (criterion maximum concentration) criterion. Moreover, nickel and lead were found in concentrations higher than the CCC (criterion constant concentration) criterion set by the US EPA for clean seawater. The rest of the elements were measured in concentrations within the permissible limits. It is therefore of environmental benefit to salvage the wreck and recycle all the WEEE found in it.

  16. Simultaneous electroencephalography-functional MRI at 3 T: an analysis of safety risks imposed by performing anatomical reference scans with the EEG equipment in place.

    Science.gov (United States)

    Nöth, Ulrike; Laufs, Helmut; Stoermer, Robert; Deichmann, Ralf

    2012-03-01

    To describe heating effects to be expected in simultaneous electroencephalography (EEG) and magnetic resonance imaging (MRI) when deviating from the EEG manufacturer's instructions; to test which anatomical MRI sequences have a sufficiently low specific absorption rate (SAR) to be performed with the EEG equipment in place; and to suggest precautions to reduce the risk of heating. Heating was determined in vivo below eight EEG electrodes, using both head and body coil transmission and sequences covering the whole range of SAR values. Head transmit coil: temperature increases were below 2.2°C for low SAR sequences, but reached 4.6°C (one subject, clavicle) for high SAR sequences; the equilibrium temperature T(eq) remained below 39°C. Body transmit coil: temperature increases were higher and more frequent over subjects and electrodes, with values below 2.6°C for low SAR sequences, reaching 6.9°C for high SAR sequences (T8 electrode) with T(eq) exceeding a critical level of 40°C. Anatomical imaging should be based on T1-weighted sequences (FLASH, MPRAGE, MDEFT) with an SAR below values for functional MRI sequences based on gradient echo planar imaging. Anatomical sequences with a high SAR can pose a significant risk, which is reduced by using head coil transmission. Copyright © 2011 Wiley-Liss, Inc.

  17. Decoding neural events from fMRI BOLD signal: A comparison of existing approaches and development of a new algorithm

    Science.gov (United States)

    Bush, Keith; Cisler, Josh

    2013-01-01

    Neuroimaging methodology predominantly relies on the blood oxygenation level dependent (BOLD) signal. While the BOLD signal is a valid measure of neuronal activity, variance in fluctuations of the BOLD signal are not only due to fluctuations in neural activity. Thus, a remaining problem in neuroimaging analyses is developing methods that ensure specific inferences about neural activity that are not confounded by unrelated sources of noise in the BOLD signal. Here, we develop and test a new algorithm for performing semi-blind (i.e., no knowledge of stimulus timings) deconvolution of the BOLD signal that treats the neural event as an observable, but intermediate, probabilistic representation of the system’s state. We test and compare this new algorithm against three other recent deconvolution algorithms under varied levels of autocorrelated and Gaussian noise, hemodynamic response function (HRF) misspecification, and observation sampling rate (i.e., TR). Further, we compare the algorithms’ performance using two models to simulate BOLD data: a convolution of neural events with a known (or misspecified) HRF versus a biophysically accurate balloon model of hemodynamics. We also examine the algorithms’ performance on real task data. The results demonstrated good performance of all algorithms, though the new algorithm generally outperformed the others (3.0% improvement) under simulated resting state experimental conditions exhibiting multiple, realistic confounding factors (as well as 10.3% improvement on a real Stroop task). The simulations also demonstrate that the greatest negative influence on deconvolution accuracy is observation sampling rate. Practical and theoretical implications of these results for improving inferences about neural activity from fMRI BOLD signal are discussed. PMID:23602664

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... may have. top of page What does the equipment look like? The traditional MRI unit is a ... traction devices and many types of life support equipment may distort the MR images and as a ...

  20. MRI compared to conventional diagnostic work-up in the detection and evaluation of invasive lobular carcinoma of the breast: a review of existing literature.

    NARCIS (Netherlands)

    Mann, R.M.; Hoogeveen, Y.L.; Blickman, J.G.; Boetes, C.

    2008-01-01

    PURPOSE: The clinical diagnosis and management of invasive lobular carcinoma (ILC) of the breast presents difficulties. Magnetic resonance imaging (MRI) has been proposed as the imaging modality of choice for the evaluation of ILC. Small studies addressing different aspects of MRI in ILC have been

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... may have. top of page What does the equipment look like? The traditional MRI unit is a ... traction devices and many types of life support equipment may distort the MR images and as a ...

  3. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... devices they may have. top of page What does the equipment look like? The traditional MRI unit ... room from the scanner. top of page How does the procedure work? Unlike conventional x-ray examinations ...

  5. MRI in the study of distal primary myopathopies and of muscular alterations due to peripheral neuropathies: possible diagnostic capacities of MR equipment with low intensity field (0.2 T) dedicated to peripheral limbs.

    Science.gov (United States)

    Messineo, D; Cremona, A; Trinci, M; Francia, A; Marini, A

    1998-09-01

    The purpose of this work was to investigate whether or not an magnetic resonance imaging (MRI) equipment with a low field intensity (0.2 T) used in the study of muscular alterations can diagnose primary or secondary myopathies, due to peripheral neuropathies. In this study the peripheral areas of all patients were examined. A total of 40 patients (23 males and 17 females) were tested. Their age ranged from 10 to 78 years age (mean age 40.8, SD +/- 19,45 years). The group includes 23 patients: 18 with Stainert Myotonic Distrophy, 5 were myositic, and the remaining 17 had peropheral neuropathies. Every patient received a clinic examination, followed by EMG and MRI. The MRI study was done with a system dedicated to the study of limbs (Artoscan, Esaote Biomedica) that used a 0.2 T permanent magnet. Spin-echo T1, T2-weighted, multiple-echo, and STIR sequences were used. A good correspondence was found between clinical and MRI data. Specifically, in the group of 23 myopathies, Sperman's index was found to be 0.80 in its correlation between the clinical examination and MRI; in the group of 17 myopathies it was found to be 0.63. A discrepancy was found among clinical examination, EMG, and MRI in patients with neuropathies who were showing a lack of myelin and mixed ones. The T2-weighted and STIR sequences had great sensitivity in showing initial changes in the muscles. The SE T1-weighted sequence was especially useful in detecting degeneration in the fibrous adipose tissue. The STIR sequence because of its high sensitivity and greater speed of response could be used instead of the SE T2 weighted particularly in the study of patients, who were noted to tolerate a prolonge period of scanning. However, because these sequences have a low signal noise ratio, they must always be associated with a SE sequence, whenever there would be need of a precise determination of the structures under study. The MRI low field intensity was also found to be a useful technique in screening

  6. Acquisition of Long-Duration, Low-Gravity Slosh Data Utilizing Existing ISS Equipment (SPHERES) for Calibration of CFD Models of Coupled Fluid-Vehicle Behavior

    Science.gov (United States)

    Schallhorn, Paul; Roth, Jacob; Marsell, Brandon; Kirk, Daniel; Gutierrez, Hector; Saenz-Otero, Alvar; Dorney, Daniel; Moder, Jeffrey

    2013-01-01

    simulates a launch vehicle upper stage propellant tank and the maneuvers replicate those of real vehicles. The design includes inertial sensors, data acquisition, image capture and data storage interfaces to the SPHERES VERTIGO computer system on board the flight article assembly. The design also includes mechanical and electronic interfaces to the existing SPHERES hardware, which include self-contained packages that can operate in conjunction with the existing SPHERES electronics

  7. Shoulder MRI

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Shoulder Magnetic resonance imaging (MRI) of the shoulder ... limitations of MRI of the shoulder? What is MRI of the shoulder? MRI of the shoulder provides ...

  8. Knee MRI

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Knee Magnetic resonance imaging (MRI) of the knee ... of a knee MRI? What is a Knee MRI? MRI of the knee provides detailed images of ...

  9. Portable MRI

    Energy Technology Data Exchange (ETDEWEB)

    Espy, Michelle A. [Los Alamos National Laboratory

    2012-06-29

    This project proposes to: (1) provide the power of MRI to situations where it presently isn't available; (2) perform the engineering required to move from lab to a functional prototype; and (3) leverage significant existing infrastructure and capability in ultra-low field MRI. The reasons for doing this: (1) MRI is the most powerful tool for imaging soft-tissue (e.g. brain); (2) Billions don't have access due to cost or safety issues; (3) metal will heat/move in high magnetic fields; (4) Millions of cases of traumatic brain injury in US alone; (5) even more of non-traumatic brain injury; (6) (e.g. stroke, infection, chemical exposure); (7) Need for early diagnostic; (8) 'Signature' wound of recent conflicts; (9) 22% of injuries; (10) Implications for post-traumatic stress disorder; and (11) chronic traumatic encephalopathy.

  10. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  11. First steps in quality control equipment MRI; Primeros pasos en el control de calidad de equipos de imagen por resonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Diaz, M.; Castaneda Arronte, M. J.; Ferreiros Vazquez, N.; Sanchez Merino, G.

    2011-07-01

    The present work aims to develop the initial stages of a program of quality control of nuclear magnetic resonance equipment. Not intended to conduct a comprehensive study covering all aspects of quality control, but gather the steps are followed and the most common problems they are encountering during the development of this program. It has been claimed that the work will be helpful to others facing the same task. Have been studied the compatibility of mannequins and procedures for the various teams. Ideally, such controls should be independent of the procedures and mannequins own commercial houses.

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... devices they may have. top of page What does the equipment look like? The traditional MRI unit ... room from the scanner. top of page How does the procedure work? Unlike conventional x-ray examinations ...

  13. Arterial Spin Labeling Blood Flow MRI: Its Role in the Early Characterization of Alzheimer’s Disease

    OpenAIRE

    Alsop, David C.; Dai, Weiying; Grossman, Murray; Detre, John A.

    2010-01-01

    Arterial spin labeling (ASL) enables the noninvasive, quantitative imaging of cerebral blood flow using standard magnetic resonance imaging (MRI) equipment. Because it requires no contrast injection, ASL can add resting functional information to MRI studies measuring atrophy and signs of ischemic injury. Key features of ASL technology that may affect studies in Alzheimer’s disease are described. The existing literature describing ASL blood flow imaging applied to Alzheimer’s disease and relat...

  14. Chest MRI

    Science.gov (United States)

    Nuclear magnetic resonance - chest; Magnetic resonance imaging - chest; NMR - chest; MRI of the thorax; Thoracic MRI ... healthy enough to filter the contrast. During the MRI, the person who operates the machine will watch ...

  15. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  16. MRI/linac integration.

    Science.gov (United States)

    Lagendijk, Jan J W; Raaymakers, Bas W; Raaijmakers, Alexander J E; Overweg, Johan; Brown, Kevin J; Kerkhof, Ellen M; van der Put, Richard W; Hårdemark, Björn; van Vulpen, Marco; van der Heide, Uulke A

    2008-01-01

    In radiotherapy the healthy tissue involvement still poses serious dose limitations. This results in sub-optimal tumour dose and complications. Daily image guided radiotherapy (IGRT) is the key development in radiation oncology to solve this problem. MRI yields superb soft-tissue visualization and provides several imaging modalities for identification of movements, function and physiology. Integrating MRI functionality with an accelerator can make these capacities available for high precision, real time IGRT. The system being built at the University Medical Center Utrecht is a 1.5T MRI scanner, with diagnostic imaging functionality and quality, integrated with a 6MV radiotherapy accelerator. The realization of a prototype of this hybrid system is a joint effort between the Radiotherapy Department of the University of Utrecht, the Netherlands, Elekta, Crawley, U.K., and Philips Research, Hamburg, Germany. Basically, the design is a 1.5 T Philips Achieva MRI scanner with a Magnex closed bore magnet surrounded by a single energy (6 MV) Elekta accelerator. Monte Carlo simulations are used to investigate the radiation beam properties of the hybrid system, dosimetry equipment and for the construction of patient specific dose deposition kernels in the presence of a magnetic field. The latter are used to evaluate the IMRT capability of the integrated MRI linac. A prototype hybrid MRI/linac for on-line MRI guidance of radiotherapy (MRIgRT) is under construction. The aim of the system is to deliver the radiation dose with mm precision based on diagnostic quality MR images.

  17. MRI Scans

    Science.gov (United States)

    Magnetic resonance imaging (MRI) uses a large magnet and radio waves to look at organs and structures inside your body. Health care professionals use MRI scans to diagnose a variety of conditions, from ...

  18. Equipment repaired is equipment gained

    Directory of Open Access Journals (Sweden)

    V Srinivasan

    2009-06-01

    Full Text Available According to WHO, at any one time, around 50 per cent of medical equipment in low- and middle-income countries cannot be used because of lack of maintenance or spare parts. We have found that unwillingness or inability to repair equipment and put it back in use is also a major cause.

  19. Chapter 12. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  20. Solar Equipment

    Science.gov (United States)

    1983-01-01

    A medical refrigeration and a water pump both powered by solar cells that convert sunlight directly into electricity are among the line of solar powered equipment manufactured by IUS (Independent Utility Systems) for use in areas where conventional power is not available. IUS benefited from NASA technology incorporated in the solar panel design and from assistance provided by Kerr Industrial Applications Center.

  1. MRI-guided brachytherapy

    Science.gov (United States)

    Tanderup, Kari; Viswanathan, Akila; Kirisits, Christian; Frank, Steven J.

    2014-01-01

    The application of MRI-guided brachytherapy has demonstrated significant growth during the last two decades. Clinical improvements in cervix cancer outcomes have been linked to the application of repeated MRI for identification of residual tumor volumes during radiotherapy. This has changed clinical practice in the direction of individualized dose administration, and mounting evidence of improved clinical outcome with regard to local control, overall survival as well as morbidity. MRI-guided prostate HDR and LDR brachytherapy has improved the accuracy of target and organs-at-risk (OAR) delineation, and the potential exists for improved dose prescription and reporting for the prostate gland and organs at risk. Furthermore, MRI-guided prostate brachytherapy has significant potential to identify prostate subvolumes and dominant lesions to allow for dose administration reflecting the differential risk of recurrence. MRI-guided brachytherapy involves advanced imaging, target concepts, and dose planning. The key issue for safe dissemination and implementation of high quality MRI-guided brachytherapy is establishment of qualified multidisciplinary teams and strategies for training and education. PMID:24931089

  2. MRI of the Chest

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Chest Magnetic resonance imaging (MRI) of the chest ... limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is ...

  3. MRI of the Prostate

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Prostate Magnetic resonance imaging (MRI) of the prostate ... limitations of MRI of the Prostate? What is MRI of the Prostate? Magnetic resonance imaging (MRI) is ...

  4. MRI of the Breast

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Breast Magnetic resonance imaging (MRI) of the breast ... limitations of MRI of the Breast? What is MRI of the Breast? Magnetic resonance imaging (MRI) is ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... This detail makes MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has ... Magnetic Resonance Imaging (MRI) Safety MRI Safety During Pregnancy Images related to Magnetic Resonance Imaging (MRI) - Chest ...

  6. Prioritizing equipment for replacement.

    Science.gov (United States)

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  7. MRI zoo

    DEFF Research Database (Denmark)

    Laustsen, Christoffer

    The basic idea was to use MRI to produce a sequence of 3D gray scale image slices of various animals, subsequentlyimaged with a clinical CT system. For this purpose, these animals were used: toad, lungfish, python snake and a horseshoe crab. Each animal was sacrificed according to standard....... MRI was done using a Philips Achieva 1.5 T system and CT was performed using a Siemens Somatom system. Axial and sagittal slices were acquired using standard T1w and T2w MRI sequences, and visualization was made using the Mistar software (Apollo Imaging Technology, Melbourne, Australia). Images were...

  8. MRI of plants and foods

    Science.gov (United States)

    Van As, Henk; van Duynhoven, John

    2013-04-01

    The importance and prospects for MRI as applied to intact plants and to foods are presented in view of one of humanity's most pressing concerns, the sustainable and healthy feeding of a worldwide increasing population. Intact plants and foods have in common that their functionality is determined by complex multiple length scale architectures. Intact plants have an additional level of complexity since they are living systems which critically depend on transport and signalling processes between and within tissues and organs. The combination of recent cutting-edge technical advances and integration of MRI accessible parameters has the perspective to contribute to breakthroughs in understanding complex regulatory plant performance mechanisms. In food science and technology MRI allows for quantitative multi-length scale structural assessment of food systems, non-invasive monitoring of heat and mass transport during shelf-life and processing, and for a unique view on food properties under shear. These MRI applications are powerful enablers of rationally (re)designed food formulations and processes. Limitations and bottlenecks of the present plant and food MRI methods are mainly related to short T2 values and susceptibility artefacts originating from small air spaces in tissues/materials. We envisage cross-fertilisation of solutions to overcome these hurdles in MRI applications in plants and foods. For both application areas we witness a development where MRI is moving from highly specialised equipment to mobile and downscaled versions to be used by a broad user base in the field, greenhouse, food laboratory or factory.

  9. Pediatric MRI

    Data.gov (United States)

    U.S. Department of Health & Human Services — The NIH Study of Normal Brain Development is a longitudinal study using anatomical MRI, diffusion tensor imaging (DTI), and MR spectroscopy (MRS) to map pediatric...

  10. Cardiac MRI

    Science.gov (United States)

    ... Activities Obesity, Nutrition, and Physical Activity Population and Epidemiology Studies Women’s Health All Science A-Z Grants & ... interfere with the MRI machine or cause skin burns. Tattoos may cause a problem because older tattoo ...

  11. Chest MRI

    Science.gov (United States)

    ... Activities Obesity, Nutrition, and Physical Activity Population and Epidemiology Studies Women’s Health All Science A-Z Grants & ... interfere with the MRI machine or cause skin burns. Tattoos may cause a problem because older tattoo ...

  12. Head MRI

    Science.gov (United States)

    ... metal zippers, and similar metallic items Removable dental work ... test. The strong magnetic fields created during an MRI can make heart pacemakers and other implants not work as well. It can also cause a piece ...

  13. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  14. Fast Reference-Based MRI

    CERN Document Server

    Weizman, Lior; Ben-Basaht, Dafna

    2015-01-01

    In many clinical MRI scenarios, existing imaging information can be used to significantly shorten acquisition time or to improve Signal to Noise Ratio (SNR). In some cases, a previously acquired image can serve as a reference image, that may exhibit similarity to the image being acquired. Examples include similarity between adjacent slices in high resolution MRI, similarity between various contrasts in the same scan and similarity between different scans of the same patient. In this paper we present a general framework for utilizing reference images for fast MRI. We take into account that the reference image may exhibit low similarity with the acquired image and develop an iterative weighted approach for reconstruction, which tunes the weights according to the degree of similarity. Experiments demonstrate the performance of the method in three different clinical MRI scenarios: SNR improvement in high resolution brain MRI, utilizing similarity between T2-weighted and fluid-attenuated inversion recovery (FLAIR)...

  15. Cleaning supplies and equipment

    Science.gov (United States)

    ... gov/ency/patientinstructions/000443.htm Cleaning supplies and equipment To use the sharing features on this page, ... to clean supplies and equipment. Disinfecting Supplies and Equipment Start by wearing the right personal protective equipment ( ...

  16. MRI Safety during Pregnancy

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z MRI Safety During Pregnancy Magnetic resonance imaging (MRI) Illness ... during the exam? Contrast material MRI during pregnancy Magnetic resonance imaging (MRI) If you are pregnant and your doctor ...

  17. Breast MRI scan

    Science.gov (United States)

    MRI - breast; Magnetic resonance imaging - breast; Breast cancer - MRI; Breast cancer screening - MRI ... radiologist) see some areas more clearly. During the MRI, the person who operates the machine will watch ...

  18. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... and Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options ... usually given through an IV in the arm. MRI Research Programs at FDA Magnetic Resonance Imaging (MRI) ...

  19. Aquatic Equipment Information.

    Science.gov (United States)

    Sova, Ruth

    Equipment usually used in water exercise programs is designed for variety, intensity, and program necessity. This guide discusses aquatic equipment under the following headings: (1) equipment design; (2) equipment principles; (3) precautions and contraindications; (4) population contraindications; and (5) choosing equipment. Equipment is used…

  20. Data quality in fMRI and simultaneous EEG-fMRI.

    Science.gov (United States)

    Ihalainen, Toni; Kuusela, Linda; Turunen, Sampsa; Heikkinen, Sami; Savolainen, Sauli; Sipilä, Outi

    2015-02-01

    To evaluate functional magnetic resonance imaging (fMRI) and simultaneous electroencephalography (EEG)-fMRI data quality in an organization using several magnetic resonance imaging (MRI) systems. Functional magnetic resonance imaging measurements were carried out twice with a uniform gel phantom on five different MRI systems with field strengths of 1.5 and 3.0 T. Several image quality parameters were measured with automatic analysis software. For simultaneous EEG-fMRI, data quality was evaluated on 3.0 T systems, and the phantom results were compared to data on human volunteers. The fMRI quality parameters measured with different MRI systems were on an acceptable level. The presence of the EEG equipment caused superficial artifacts on the phantom image. The typical artifact depth was 15 mm, and no artifacts were observed in the brain area in the images of volunteers. Average signal-to-noise ratio (SNR) reduction in the phantom measurements was 15 %, a reduction of SNR similar to that observed in the human data. We also detected minor changes in the noise of the EEG signal during the phantom measurement. The phantom proved valuable in the successful evaluation of the data quality of fMRI and EEG-fMRI. The results fell within acceptable limits. This study demonstrated a repeatable method to measure and follow up on the data quality of simultaneous EEG-fMRI.

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Chest Magnetic resonance imaging (MRI) of the chest ... limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is ...

  2. Pathfinder to EXIST: ProtoEXIST

    Science.gov (United States)

    Garson, A. B., III; Allen, B.; Baker, R. G.; Barthelmy, S. D.; Burke, M.; Burnham, J.; Chammas, N.; Collins, J.; Cook, W. R.; Copete, A.; Gehrels, N.; Gauron, T.; Grindlay, J.; Harrison, F. A.; Hong, J.; Howell, J.; Krawczynski, H.; Labov, S.; Said, B.; Sheikh Sheikh, S.

    2008-04-01

    We describe the ProtoEXIST instrument, our fist-generation wide-field hard X-ray imaging (20 - 600 keV) balloon-borne telescope. The ProtoEXIST program is a pathfinder for the Energetic X-ray Imaging Survey Telescope (EXIST), a candidate for the Black Hole Finder Probe. ProtoEXIST consists of two independent coded-aperture telescopes using pixellated (2.5mm pitch) CZT detectors. The two telescopes will provide performance comparison of two shielding configurations, for optimization of the EXIST design. We report on the science goals and designs of both ProtoEXIST and EXIST and their implications for hard X-ray astronomy and astrophysics.

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... as chest x-ray or CT. A special form of MRI called magnetic resonance angiography (MRA) is ... not to have an MRI exam during the first trimester unless medically necessary. MRI may not always ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... the limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is a noninvasive ... top of page What are some common uses of the procedure? MR imaging of the chest is ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... in the first three to four months of pregnancy unless the potential benefit from the MRI exam ... the MRI Safety page for more information about pregnancy and MRI. If you have claustrophobia (fear of ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the chest is performed ...

  8. Animal MRI Core

    Data.gov (United States)

    Federal Laboratory Consortium — The Animal Magnetic Resonance Imaging (MRI) Core develops and optimizes MRI methods for cardiovascular imaging of mice and rats. The Core provides imaging expertise,...

  9. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how does it ... and MRI Breast-feeding and MRI What is MRI and how does it work? Magnetic resonance imaging, ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  11. MRI of the Musculoskeletal System

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Musculoskeletal Magnetic resonance imaging (MRI) uses a powerful ... the limitations of a Musculoskeletal MRI? What is MRI of the Musculoskeletal System? Magnetic resonance imaging (MRI) ...

  12. Magnetic Resonance Imaging (MRI) - Spine

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Spine Magnetic resonance imaging (MRI) of the spine ... limitations of MRI of the Spine? What is MRI of the Spine? Magnetic resonance imaging (MRI) is ...

  13. Radiative MRI Coil Design Using Parasitic Scatterers

    DEFF Research Database (Denmark)

    Sanchez-Heredia, Juan D.; Avendal, Johan; Bibic, Adnan

    2018-01-01

    Conventionally, radiofrequency (RF) coils used for magnetic resonance imaging (MRI) are electrically small and designed for nearfield operation. Therefore, existing antenna design techniques are mostly irrelevant for RF coils. However, the use of higher frequencies in ultrahigh field (UHF) MRI...... allows for antenna design techniques to be adapted to RF coil designs. This study proposes the use of parasitic scatterers to improve the performance of an existing 7T MRI coil called the single-sided adapted dipole (SSAD) antenna. The results reveal that scatterers arranged in a Yagi fashion can...... suitable for use in high density arrays. These findings show the potential of parasitic scatterers as an effective method to improve the performance of existing radiative MRI coils....

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Chest Magnetic resonance imaging (MRI) of the chest uses a powerful ... Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  15. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  16. Synthetic MRI for visualization of quantitative MRI

    OpenAIRE

    Peterson, Erika

    2013-01-01

    Magnetic resonance imaging (MRI) is an imaging technique that is used in hospitals worldwide. The images are acquired through the use of an MRI scanner and the clinical information is provided through the image contrast, which is based on the magnetic properties in biological tissue. By altering the scanner settings, images with different contrast properties can be obtained. Conventional MRI is a qualitative imaging technique and no absolute measurements are performed. At Center for Medical I...

  17. Prospective motion correction for MRI using EEG-equipment

    DEFF Research Database (Denmark)

    Andersen, Mads; Madsen, Kristoffer Hougaard; Hanson, Lars G.

    2016-01-01

    A new prospective motion correction technique is presented that is based on signals from gradient switching, in an EEG-cap with interconnected electrodes the subject wears during scanning. The method has no line-of-sight limitations as optical methods, requires no interleaved navigator modules...

  18. Requirements for existing buildings

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Wittchen, Kim Bjarne

    This report collects energy performance requirements for existing buildings in European member states by June 2012.......This report collects energy performance requirements for existing buildings in European member states by June 2012....

  19. Canalis basilaris medianus: MRI

    Energy Technology Data Exchange (ETDEWEB)

    Jacquemin, C. [Dept. of Radiology, King Khaled Eye Specialist Hospital, Riyadh (Saudi Arabia); Bosley, T.M.; Al Saleh, M. [Div. of Neuro-ophthalmology, King Khaled Eye Specialist Hospital, Riyadh (Saudi Arabia); Mullaney, P. [Division of Pediatrics, King Khaled Eye Specialist Hospital, Riyadh (Saudi Arabia)

    2000-02-01

    We report the MRI appearances of an developmental anatomical variant of the basiocciput, with neuroimaging findings (CT and MRI). Such variants are commonly asymptomatic, but may be associated with episodes of meningitis. (orig.)

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Chest Magnetic resonance imaging (MRI) of the chest uses a powerful magnetic field, radio waves and a computer to produce ...

  1. Abdominal MRI scan

    Science.gov (United States)

    Nuclear magnetic resonance - abdomen; NMR - abdomen; Magnetic resonance imaging - abdomen; MRI of the abdomen ... radiologist see certain areas more clearly. During the MRI, the person who operates the machine will watch ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... may not fit into the opening of certain types of MRI machines. The presence of an implant ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... treatment. See the MRI Safety page for more information about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your physician for ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... a very small chance of irritation of your skin at the site of the IV tube insertion. ... detail makes MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed pictures ... as chest x-ray or CT. A special form of MRI called magnetic resonance angiography (MRA) is ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scan. Because they can interfere with the magnetic field of the MRI unit, metal and electronic items ... and braces usually are not affected by the magnetic field, but they may distort images of the facial ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... eyes or other reactions. If you experience allergic symptoms, notify the technologist. A radiologist or other physician ... detail makes MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... risking the side effects of conventional (catheter) angiography . Risks The MRI examination poses almost no risk to ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... detail makes MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven ... the technologist or nurse will monitor your vital signs to minimize this risk. Although the strong magnetic ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... other internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians ... computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging ( ... heart, valves, great vessels, etc.). top of page What are some common uses of the procedure? MR ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If sedation is used, there ... patient story here Images × ... Resonance Imaging (MRI) Safety MRI Safety During Pregnancy Images related to Magnetic ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... women should not have this exam in the first three to four months of pregnancy unless the ... not to have an MRI exam during the first trimester unless medically necessary. MRI may not always ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven valuable in ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... clearer and more detailed than with other imaging methods. This detail makes MRI an invaluable tool in ... might be obscured by bone with other imaging methods. The contrast material used in MRI exams is ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... devices require a short period of time after placement (usually six weeks) before being safe for MRI ... devices that contain metal may malfunction or cause problems during an MRI exam. Nephrogenic systemic fibrosis is ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Chest? High-quality images are assured only if you are able ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... MRI. For more information, consult your radiologist. The computer workstation that processes the imaging information is located ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... does not completely surround you. Some newer MRI machines have a larger diameter bore which can be ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ...

  3. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  4. fMRI Neuroinformatics

    DEFF Research Database (Denmark)

    Nielsen, Finn Årup; Christensen, Mark Schram; Madsen, Kristoffer M.

    2006-01-01

    Functional magnetic resonance imaging (fMRI) generates vast amounts of data. The handling, processing, and analysis of fMRI data would be inconceivable without computer-based methods. fMRI neuroinformatics is concerned with research, development, and operation of these methods. Reconstruction...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... or CT. A special form of MRI called magnetic resonance angiography (MRA) is helpful to assess the vessels of ... child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance Imaging (MRI) Safety MRI Safety During Pregnancy Images ...

  6. MRI of Cerebellar Infarction

    NARCIS (Netherlands)

    De Cocker, Laurens J L; Lövblad, Karl-Olof; Hendrikse, Jeroen

    2017-01-01

    BACKGROUND: MRI is the imaging modality of choice for diagnosing brain infarction. Because of few or atypical clinical symptoms and a relatively low sensitivity of CT scans, many cerebellar infarctions may be detected only with MRI. With adequate recognition of cerebellar infarction on MRI and

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI exam is assumed to outweigh the potential risks. Pregnant women should not receive injections of gadolinium contrast material except when absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. If you have claustrophobia ( ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging (MRI) is a noninvasive ... heart, valves, great vessels, etc.). top of page What are some common uses of the procedure? MR ...

  9. MRI in acute poliomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Kornreich, L. [Imaging Department, The Schneider Children`s Medical Centre of Israel, Kaplan Street, Petah Tiqva 49202 (Israel)]|[Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Dagan, O. [The Intensive Care Unit, The Schneider Children`s Medical Centre of Israel, Beilinson Medical Campus, Petah Tiqva (Israel)]|[Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Grunebaum, M. [Imaging Department, The Schneider Children`s Medical Centre of Israel, Kaplan Street, Petah Tiqva 49202 (Israel)]|[Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel)

    1996-05-01

    MRI can be used in the diagnosis of anterior horn infection and for assessing the extent of disease. There are no specific MRI signs to differentiate between the various possible pathogens. This is demonstrated in the present case of poliomyelitis, in which MRI of the spine played an important role in establishing the diagnosis. (orig.). With 1 fig.

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... tumors. MRI can help physicians evaluate both the structure of an organ and how it is working. MRI enables the discovery of abnormalities that might be obscured by bone with other imaging methods. The contrast material used in MRI exams is less likely to ...

  11. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  12. Interface transfer of equipment

    Energy Technology Data Exchange (ETDEWEB)

    Ashton, I.J.

    1989-04-01

    This article details the interface transfer of heavy-duty face equipment from 5's to 6's face in the Great Row Seam at Silverdale Colliery, British Coal, Western Area. The salvaged face was roofbolted using leg-mounted Wombat drilling rigs. All heavy-duty equipment was transported by FSV's. 5 figs.

  13. Organizing Knowing in Interdisciplinary MRI Practice

    DEFF Research Database (Denmark)

    Yoshinaka, Yutaka

    This paper addresses organizational knowledge practices pertaining to the interdisciplinary work of Magnetic Resonance Imaging (MRI) at a hospital radiology department. The setting occasions an interesting venue for exploring domestication of MRI as it unfolds in distributed settings of collective...... envisaged to deal with the department’s appropriation of a new MRI scanner, occasioned by the replacement of an existing model. Work was reorganised to reflect this aspect in the practice protocols from early on, where personnel previously assigned only to other imaging modalities such as the department......'s CT-scan and X-ray machines, were to take on MRI scanning, on an albeit rotational basis. Opening up to a broader group of operators to the scanning practice was to allow for organizational flexibility and a broader basis for competence building among radiology staff, where different occupational...

  14. [Medical Equipment Maintenance Methods].

    Science.gov (United States)

    Liu, Hongbin

    2015-09-01

    Due to the high technology and the complexity of medical equipment, as well as to the safety and effectiveness, it determines the high requirements of the medical equipment maintenance work. This paper introduces some basic methods of medical instrument maintenance, including fault tree analysis, node method and exclusive method which are the three important methods in the medical equipment maintenance, through using these three methods for the instruments that have circuit drawings, hardware breakdown maintenance can be done easily. And this paper introduces the processing methods of some special fault conditions, in order to reduce little detours in meeting the same problems. Learning is very important for stuff just engaged in this area.

  15. [MRI methods for pulmonary ventilation and perfusion imaging].

    Science.gov (United States)

    Sommer, G; Bauman, G

    2016-02-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.

  16. Defining active sacroiliitis on MRI for classification of axial spondyloarthritis

    DEFF Research Database (Denmark)

    Lambert, Robert G W; Bakker, Pauline A C; van der Heijde, Désirée

    2016-01-01

    OBJECTIVES: To review and update the existing definition of a positive MRI for classification of axial spondyloarthritis (SpA). METHODS: The Assessment in SpondyloArthritis International Society (ASAS) MRI working group conducted a consensus exercise to review the definition of a positive MRI...... for inclusion in the ASAS classification criteria of axial SpA. Existing definitions and new data relevant to the MRI diagnosis and classification of sacroiliitis and spondylitis in axial SpA, published since the ASAS definition first appeared in print in 2009, were reviewed and discussed. The precise wording...... of the existing definition was examined in detail and the data and a draft proposal were presented to and voted on by the ASAS membership. RESULTS: The clear presence of bone marrow oedema on MRI in subchondral bone is still considered to be the defining observation that determines the presence of active...

  17. A 4-channel 3 Tesla phased array receive coil for awake rhesus monkey fMRI and diffusion MRI experiments.

    Science.gov (United States)

    Khachaturian, Mark Haig

    2010-01-01

    Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments are performed with single coils which suffer from severe EPI distortions which limit resolution. By constructing phased array coils for monkey MRI studies, gains in SNR and anatomical accuracy (i.e., reduction of EPI distortions) can be achieved using parallel imaging. The major challenges associated with constructing phased array coils for monkeys are the variation in head size and space constraints. Here, we apply phased array technology to a 4-channel phased array coil capable of improving the resolution and image quality of full brain awake monkey fMRI and diffusion MRI experiments. The phased array coil is that can adapt to different rhesus monkey head sizes (ages 4-8) and fits in the limited space provided by monkey stereotactic equipment and provides SNR gains in primary visual cortex and anatomical accuracy in conjunction with parallel imaging and improves resolution in fMRI experiments by a factor of 2 (1.25 mm to 1.0 mm isotropic) and diffusion MRI experiments by a factor of 4 (1.5 mm to 0.9 mm isotropic).

  18. 46 CFR 184.115 - Applicability to existing vessels.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Applicability to existing vessels. 184.115 Section 184... 100 GROSS TONS) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT General Provisions § 184.115 Applicability to existing vessels. (a) An existing vessel need not comply with §§ 184.402(c), 184.404, 184.410...

  19. Dental MRI using wireless intraoral coils

    Science.gov (United States)

    Ludwig, Ute; Eisenbeiss, Anne-Katrin; Scheifele, Christian; Nelson, Katja; Bock, Michael; Hennig, Jürgen; von Elverfeldt, Dominik; Herdt, Olga; Flügge, Tabea; Hövener, Jan-Bernd

    2016-03-01

    Currently, the gold standard for dental imaging is projection radiography or cone-beam computed tomography (CBCT). These methods are fast and cost-efficient, but exhibit poor soft tissue contrast and expose the patient to ionizing radiation (X-rays). The need for an alternative imaging modality e.g. for soft tissue management has stimulated a rising interest in dental magnetic resonance imaging (MRI) which provides superior soft tissue contrast. Compared to X-ray imaging, however, so far the spatial resolution of MRI is lower and the scan time is longer. In this contribution, we describe wireless, inductively-coupled intraoral coils whose local sensitivity enables high resolution MRI of dental soft tissue. In comparison to CBCT, a similar image quality with complementary contrast was obtained ex vivo. In-vivo, a voxel size of the order of 250•250•500 μm3 was achieved in 4 min only. Compared to dental MRI acquired with clinical equipment, the quality of the images was superior in the sensitive volume of the coils and is expected to improve the planning of interventions and monitoring thereafter. This method may enable a more accurate dental diagnosis and avoid unnecessary interventions, improving patient welfare and bringing MRI a step closer to becoming a radiation-free alternative for dental imaging.

  20. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  1. MRI in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Mulert, Christoph [UKE, Hamburg (Germany). Psychiatry Neuroimaging Branch; Shenton, Martha E. (ed.) [Harvard Medical School, Boston, MA (United States). Dept. of Psychiatry and Radiology

    2014-07-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  3. The EXIST OIRT

    Science.gov (United States)

    Allen, Branden; Golisano, C.; Kutyrev, A.; Moseley, H.; Grindlay, J.; Hong, J.; EXIST Team

    2009-01-01

    The EXIST Optical / Infrared Telescope (OIRT) has been integrated into the EXIST concept design for the determination GRB redshifts on orbit and to preform follow up source identification and studies following the generation of a trigger from the EXIST high energy telescope (HET). The base OIRT main design has been inherited from the NextView OIRT has been operating in low earth orbit since September of 2007 and is currently being used for the acquisition of geospatial data. After reconfiguration of the instrumentation for astrophysical observations the OIRT will have an angular resolution of 0.15" and a 5'×5' field of view and be sensitive to emission in the range of 0.4 $\\mu$m - 2.2 $\\mu$m. Passive cooling of the tertiary, secondary, and primary mirrors will enable observation into the Ks$ band.

  4. About Personal Protective Equipment (PPE)

    Science.gov (United States)

    ... Equipment for Infection Control Questions About Personal Protective Equipment (PPE) Share Tweet Linkedin Pin it More sharing ... Print Q1. How do manufacturers ensure personal protective equipment (PPE) is safe and effective? A1. To help ...

  5. EPA’s Response Equipment

    Science.gov (United States)

    EPA maintains a variety of equipment to respond to hazardous substance emergencies such as releases or oil spills regardless of their nature, size, or location. This include ASPECT, PHILIS, Equipment Module (EM), and personal protective equipment.

  6. A novel approach to calibrate the Hemodynamic Model using functional Magnetic Resonance Imaging (fMRI) measurements

    KAUST Repository

    Khoram, Nafiseh

    2016-01-21

    Background The calibration of the hemodynamic model that describes changes in blood flow and blood oxygenation during brain activation is a crucial step for successfully monitoring and possibly predicting brain activity. This in turn has the potential to provide diagnosis and treatment of brain diseases in early stages. New Method We propose an efficient numerical procedure for calibrating the hemodynamic model using some fMRI measurements. The proposed solution methodology is a regularized iterative method equipped with a Kalman filtering-type procedure. The Newton component of the proposed method addresses the nonlinear aspect of the problem. The regularization feature is used to ensure the stability of the algorithm. The Kalman filter procedure is incorporated here to address the noise in the data. Results Numerical results obtained with synthetic data as well as with real fMRI measurements are presented to illustrate the accuracy, robustness to the noise, and the cost-effectiveness of the proposed method. Comparison with Existing Method(s) We present numerical results that clearly demonstrate that the proposed method outperforms the Cubature Kalman Filter (CKF), one of the most prominent existing numerical methods. Conclusion We have designed an iterative numerical technique, called the TNM-CKF algorithm, for calibrating the mathematical model that describes the single-event related brain response when fMRI measurements are given. The method appears to be highly accurate and effective in reconstructing the BOLD signal even when the measurements are tainted with high noise level (as high as 30%).

  7. Does Unconscious Racism Exist?

    Science.gov (United States)

    Quillian, Lincoln

    2008-01-01

    This essay argues for the existence of a form of unconscious racism. Research on implicit prejudice provides good evidence that most persons have deeply held negative associations with minority groups that can lead to subtle discrimination without conscious awareness. The evidence for implicit attitudes is briefly reviewed. Criticisms of the…

  8. A Guide for Equipping Industrial Arts Facilities.

    Science.gov (United States)

    American Industrial Arts Association, Washington, DC. Equipment Guide Committee.

    A guide for planning new and revising existing industrial arts facilities which gives a listing of tools and equipment recommended for each of the major areas of instruction (automotive and power mechanics, ceramics, drafting, electronics, elementary, general shop, graphic arts, metalworking, plastics, and woodworking). General descriptions and…

  9. Equipment Grafting in Telecommunication Industry (Case Study ...

    African Journals Online (AJOL)

    ... existing network in the form of Upgrades and Expansion efforts. This paper appraises these grafting processes. It introduces the subject matter, highlights the performance capabilities and usage constraints of a variety of switching and transmission equipment. It also gives insight into the on-going grafting efforts in NITEL.

  10. Quantifying Pathology in Diffusion Weighted MRI

    NARCIS (Netherlands)

    Caan, M.W.A.

    2010-01-01

    In this thesis algorithms are proposed for quantification of pathology in Diffusion Weighted Magnetic Resonance Imaging (DW-MRI) data. Functional evidence for brain diseases can be explained by specific structural loss in the white matter of the brain. That is, certain biomarkers may exist where the

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or patients with claustrophobia. Other MRI machines are open on the sides (open MRI). Open units are especially helpful for examining larger patients or those with claustrophobia. Newer open MRI units provide very high quality images for ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... top of page What are some common uses of the procedure? MR imaging of the head is ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... in the first three to four months of pregnancy unless the potential benefit from the MRI exam ... the MRI Safety page for more information about pregnancy and MRI. If you have claustrophobia (fear of ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... detail makes MRI an invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven ... in diagnosing a broad range of conditions, including cancer, heart and ... tissues, except for lung abnormalities where Chest CT is a preferred imaging ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... pediatric facilities have child life personnel who can work with younger children to help avoid the need for sedation or anesthesia. They prepare the children for MRI by showing them a dummy scanner, play the noises that the child might hear during the MRI ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various ... seen by other imaging modalities, such as chest x-ray or CT. A special form of MRI called ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... lesions seen by other imaging modalities, such as chest x-ray or CT. A special form of MRI called ... perform than other imaging modalities. MRI of the chest takes more time than an x-ray or CT exam. Because of the length of ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... zippers and similar metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In ... scanner. top of page How does the procedure work? Unlike ... (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses ...

  2. Cervical MRI scan

    Science.gov (United States)

    ... cancer in the spine Arthritis in the spine MRI works better than CT scan in diagnosing these problems ... test. The strong magnetic fields created during an MRI can cause heart pacemakers and other implants to not work as well. It can also cause a piece ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... Whether a child requires sedation depends on the child's age, intellectual development and the type of exam. Moderate and conscious ... for MRI by showing them a dummy scanner, play the noises that the child might hear during the MRI exam, answer any ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits MRI is a ... resonance imaging harms the fetus, pregnant women usually are advised not to have ... may take more time to perform than other imaging modalities. MRI of ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  7. Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain

    DEFF Research Database (Denmark)

    Andreasen, Daniel; Van Leemput, Koen; Hansen, Rasmus H.

    2015-01-01

    Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are n...... on conventional T1-weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel-based and atlas-based methods and showed a promising potential for RT of the brain based only on MRI.......Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan...... are not uniquely related to electron density. To solve the task, voxel-based or atlas-based models have typically been used. The voxel-based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas-based models require deformable registrations of conventional MRI...

  8. Background Studies for EXIST

    Science.gov (United States)

    Wilson, Colleen A.; Pendleton, G. N.; Fishman, G. J.

    2004-01-01

    We present results from a study of the trapped proton and electron background for several orbital inclinations and altitudes. This study includes time dependent effects. In addition we describe a 3 component cosmic background model developed at the University of Southampton, UK. The three components are cosmic diffuse gamma rays, atmospheric albedo gamma rays, and cosmic ray protons. We present examples of how this model was applied to BATSE and discuss its application to EXIST.

  9. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    bed, and a digital clock and a transponder helped to locate the camera. Equipment for the analysis of the nodules such as x-ray fluorescence and atomic absorption spectrophotometers were installed aboard MV Skandi Surveyor and MV Fernella and MV G A...

  10. Existing chemicals: international activities.

    Science.gov (United States)

    Purchase, J F

    1989-01-01

    The standards of care used in the protection of the health and safety of people exposed to chemicals has increased dramatically in the last decade. Standards imposed by regulation and those adopted by industry have required a greater level of knowledge about the hazards of chemicals. In the E.E.C., the 6th amendment of the dangerous substances directive imposed the requirement that al new chemicals should be tested according to prescribed programme before introduction on to the market. The development of a European inventory of existing chemicals was an integral part of the 6th amendment. It has now become clear that increased standards of care referred to above must be applied to the chemicals on the inventory list. There is, however, a considerable amount of activity already under way in various international agencies. The OECD Chemicals Programme has been involved in considering the problem of existing chemicals for some time, and is producing a priority list and action programme. The International Programme on Chemical Safety produces international chemical safety cards, health and safety guides and environmental health criteria documents. The international register of potentially toxic compounds (part of UNEP) has prepared chemical data profiles on 990 compounds. The International Agency for Research on Cancer prepared monographs on the carcinogenic risk of chemicals to man. So far 42 volumes have been prepared covering about 900 substances. IARC and IPCS also prepare periodic reports on ongoing research on carcinogenicity or toxicity (respectively) of chemicals. The chemical industry through ECETOC (the European Chemical Industry Ecology and Toxicology Centre) has mounted a major initiative on existing chemicals. Comprehensive reviews of the toxicity of selected chemicals are published (Joint Assessment of Commodity Chemicals). In its technical report no. 30 ECETOC lists reviews and evaluations by major national and international organisations, which provides

  11. Do multiquark hadrons exist

    Energy Technology Data Exchange (ETDEWEB)

    Weinstein, J.; Isgur, N.

    1982-03-08

    The qqq-barq-bar system has been examined by solving the four-particle Schroedinger equation variationally. The main findings are that: (1) qqq-barq-bar bound states normally do not exist, (2) the cryptoexotic 0/sup + +/ sector of this system with KK-bar quantum numbers is probably the only exception to (1) and its bound states can be identified with the S* and delta just below KK-bar threshold, (3) qqq-barq-bar bound states provide a model for the weak binding and color-singlet clustering observed in nuclei, and (4) there is no indication that this system has strong resonances.

  12. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Ultrasound- and MRI-Guided Prostate Biopsy Ultrasound- and MRI-guided prostate ... MRI-guided Prostate Biopsy? What is Ultrasound- and MRI-guided Prostate Biopsy? Ultrasound- and MRI-guided prostate ...

  13. MRI of the Body (Chest, Abdomen, Pelvis)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Body Magnetic resonance imaging (MRI) of the body ... limitations of MRI of the Body? What is MRI of the Body? Magnetic resonance imaging (MRI) is ...

  14. An analysis of USMC heavy construction equipment (HCE) requirements

    OpenAIRE

    Blaxton, Allen C.; Fay, Michael J.; Hansen, Cheryl M.; Zuchristian, Christopher M.

    2003-01-01

    MBA Professional Report Approved for public release; distribution is unlimited. According to I and L, HQMC, the Marine Corps needs to re-evaluate current operational requirements for engineer construction equipment. Acquisition and force allocation levels for equipment have remained essentially at constant 1970's, Cold War levels. Because acquisition and allocation levels haven't changed at the same rate as personnel, there is a perception that much of the existing equipment is unnecess...

  15. SOLUTION FOR AN EQUIPMENT OF RAILWAY BRIDGE MONITORING

    Directory of Open Access Journals (Sweden)

    Liviu Mihai SIMA

    2009-11-01

    Full Text Available This paper presents a solution for the railway bridges monitoring based on the use of already existing equipments in the railway installations and some new equipments based on photo-elements, as well. This kind of equipments can function in continue and discontinuous regime, means of them tracking down if the bridge piles suffered movements by different reasons. This aspect can put in danger the safety of the circulation on that bridge.

  16. Repowering existing plants

    Energy Technology Data Exchange (ETDEWEB)

    Steazel, W.C.; Sopocy, D.M.; Pace, S.E.

    1998-07-01

    Increased competition among power generation companies, changes in generating system load requirements, lower allowable plant emissions, and changes in fuel availability and cost accentuate the need to closely assess the economics and performances of older electric generation units. Generally, decisions must be made as to whether these units should be retired and replaced with new generation capacity, whether capacity should be purchased from other generation companies, or if these existing units should be repowered. These decisions usually require the evaluation of many factors including; environmental discharge limits, permitting requirements, generating load demand increases, options for increasing the benefits of using existing facilities (e.g.; increasing efficiency and output), fuel cost increases, transmission requirements and access, optional plant designs. Many of these factors need to be used in the analysis based on a range rather than one specific value to test for changes in the selection of the best option because of future uncertainties. Usually complicated analysis results because of all the factors involved. Computer products that integrate performance and financial analysis can provide substantial value by enabling the user to evaluate the applicable plant options and range of input. The SOAPP (State-of-the-Art Power Plant) family of software products provides easy to use tools for rapid, thorough and economical evaluation of plant option. Repowering evaluation methodology typically used in the US, technology options, and available SOAPP repowering software are reviewed in this paper.

  17. Strategy for conformity of non-standard cryogenic equipment

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    CERN as an intergovernmental organization establishes its own Safety Rules as necessary for its proper functioning. In particular, the CERN General Safety Instruction for cryogenic equipment requires that cryogenic pressure equipment at CERN shall comply with the European Pressure Equipment Directive (PED). However, due to the particular features of some of the cryogenic equipment required for the accelerators, as well as the existence of international collaborations with in-kind contributions from non-EU countries, full compliance with the PED may not always be achieved. This situation is foreseen in the Safety Rules, where CERN HSE will define the Safety requirements applicable to such equipment as well as any eventual additional compensatory measure as to ensure a commensurate level of Safety for our pressure equipment. Where compliance with PED may not be achieved, CERN HSE will become the de facto Notified Body and therefore be in charge of the assessment of the conformity of the equipment to the applica...

  18. Experience of brain checkup by MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Youichi [Self Defence Force Sasebo Hospital, Nagasaki (Japan); Hirata, Fumihiko; Gotoh, Masayuki; Fujita, Kazuyuki; Makiyama, Takao; Ishikawa, Junichiro

    1996-09-01

    We performed head MRI and MR angiography (MRA) to find asymptomatic central nervous system (CNS) diseases and to prevent their development as a group health care. We performed 583 head MRI and MRAs since on March 1991 for the staff lived in Self Defence Force (SDF) Maizuru guard area whose age was 40 years, who reached the retirement age and had the risk factor of the cerebral vascular disease. We found 119 subcortical lesions, 26 asymptomatic cerebral infarctions, 6 unruptured cerebral aneurysm, 2 pituitary adenomas, 4 venous angiomas. For 5 cases of asymptomatic cerebral infarction, we prescribed anti-platelet agglutination drugs, there was no people whose disease became symptomatic. For unruptured cerebral aneurysms and pituitary adenomas, we did operation, everyone attained social rehabilitation. Before equipment of the MRI in SDF Maizuru hospital, 2 ruptured cerebral aneurysms occurs. There were no subarachnoid hemorrhage patient since our challenge started in SDF Maizuru guard area. It is useful to clarify the etiology of CNS disease and for group health care, using head MRI as medical checkup. (author)

  19. Anesthetic equipment, facilities and services available for pediatric ...

    African Journals Online (AJOL)

    Background: Facilities and equipment are known to contribute to improved patient care and outcome. Hospitals for sub‑specialized pediatric anesthetic service are routinely available worldwide. In Nigeria, such hospitals now exist. It is therefore relevant to study the facilities and equipment available for pediatric anesthetic ...

  20. An H-module linear actuator for medical equipment applications

    DEFF Research Database (Denmark)

    Liu, Xiao; Wu, Keyuan; ye, yunyue

    2012-01-01

    An H-module linear actuator (HMLA) is proposed in this paper for medical equipment applications. Compared to the existing linear actuators used in medical equipment, the proposed H-module linear actuator has much lower normal force, which makes use of an additional air-suspension system unnecessary...

  1. Existence of Minkowski space

    CERN Document Server

    Wagner, Serge

    2016-01-01

    Physics textbooks present Minkowski space as an almost pure mathematical construct, without any explicit restriction on a domain where it is applicable in physics. Meanwhile, its physical meaning cannot but follow the same premises as those which underlies the special relativity theory: motion of free point particles and propagation of electromagnetic waves. However, the common formalism of coordinate transformations between any two inertial frames appears too ponderous to infer the existence of Minkowski space. For this reason, the time dilation and retardation, the contraction of the length along and the spatial invariance across the direction of relative motion of two frames are presented in a coordinate-free manner. This results in the transformation between two frames in the form of relationships between the time moments and the components of the position vector of a given event, along and across the directions of the frames' motion. The obtained transformation rules for the components of the position ve...

  2. Lebesgue Sets Immeasurable Existence

    Directory of Open Access Journals (Sweden)

    Diana Marginean Petrovai

    2012-12-01

    Full Text Available It is well known that the notion of measure and integral were released early enough in close connection with practical problems of measuring of geometric figures. Notion of measure was outlined in the early 20th century through H. Lebesgue’s research, founder of the modern theory of measure and integral. It was developed concurrently a technique of integration of functions. Gradually it was formed a specific area todaycalled the measure and integral theory. Essential contributions to building this theory was made by a large number of mathematicians: C. Carathodory, J. Radon, O. Nikodym, S. Bochner, J. Pettis, P. Halmos and many others. In the following we present several abstract sets, classes of sets. There exists the sets which are not Lebesgue measurable and the sets which are Lebesgue measurable but are not Borel measurable. Hence B ⊂ L ⊂ P(X.

  3. MRI in sarcoglycanopathies

    DEFF Research Database (Denmark)

    Tasca, Giorgio; Monforte, Mauro; Díaz-Manera, Jordi

    2018-01-01

    OBJECTIVES: To characterise the pattern and spectrum of involvement on muscle MRI in a large cohort of patients with sarcoglycanopathies, which are limb-girdle muscular dystrophies (LGMD2C-2F) caused by mutations in one of the four genes coding for muscle sarcoglycans. METHODS: Lower limb MRI scans......, while lower leg muscles were relatively spared even in advanced disease. A proximodistal gradient of involvement of vasti muscles was a consistent finding in these patients, including the most severe ones. CONCLUSIONS: Muscle involvement on MRI is consistent in patients with LGMD2C-F and can be helpful...

  4. EXIST Perspective for SFXTs

    Science.gov (United States)

    Ubertini, Pietro; Sidoli, L.; Sguera, V.; Bazzano, A.

    2009-12-01

    Supergiant Fast X-ray Transients (SFXTs) are one of the most interesting (and unexpected) results of the INTEGRAL mission. They are a new class of HMXBs displaying short hard X-ray outbursts (duration less tha a day) characterized by fast flares (few hours timescale) and large dinamic range (10E3-10E4). The physical mechanism driving their peculiar behaviour is still unclear and highly debated: some models involve the structure of the supergiant companion donor wind (likely clumpy, in a spherical or non spherical geometry) and the orbital properties (wide separation with eccentric or circular orbit), while others involve the properties of the neutron star compact object and invoke very low magnetic field values (B 1E14 G, magnetars). The picture is still highly unclear from the observational point of view as well: no cyclotron lines have been detected in the spectra, thus the strength of the neutron star magnetic field is unknown. Orbital periods have been measured in only 4 systems, spanning from 3.3 days to 165 days. Even the duty cycle seems to be quite different from source to source. The Energetic X-ray Imaging Survey Telescope (EXIST), with its hard X-ray all-sky survey and large improved limiting sensitivity, will allow us to get a clearer picture of SFXTs. A complete census of their number is essential to enlarge the sample. A long term and continuous as possible X-ray monitoring is crucial to -(1) obtain the duty cycle, -(2 )investigate their unknown orbital properties (separation, orbital period, eccentricity),- (3) to completely cover the whole outburst activity, (4)-to search for cyclotron lines in the high energy spectra. EXIST observations will provide crucial informations to test the different models and shed light on the peculiar behaviour of SFXTs.

  5. Overview of intraoperative MRI in neurosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Shiino, Akihiko; Matsuda, Masayuki [Shiga Univ. of Medical Science, Otsu (Japan)

    2002-01-01

    This review describes usefulness, prospect and present problems of intraoperative MRI in neurosurgery. MRI equipments for the surgery have to have a wide, open space and have those magnets of short cylindrical, biplanar (clam shell), dual air core superconducting solenoidal (double doughnut) and targeted FOV (field of view) type. Devices required for the surgery are specific and in author's facility, they are classified into 4 zones depending on the region of their use. Application of the surgery involves biopsy, drainage of cyst and abscess, hematoma evacuation, nerve block, thermotherapy (interstitial laser, RF ablation, focused untrasonic and cryosurgery), local drug therapy, chemoablation, vascular intervention and tumor extraction, of which actual procedures and pictures are presented together with, in particular, MR-guided thermotherapy, ablation therapy of brain tumors, endoscopic surgery and minimally invasive therapy of the spine. A navigation software, 3D SlicerTM system, is introduced for interventional imaging. Safety measures are emphasized for the operation. (K.H.)

  6. MODERNIZATION OF CUPOLA EQUIPMENT

    Directory of Open Access Journals (Sweden)

    S. L. Rovin

    2015-01-01

    Full Text Available This article presents an automated cupola complex, developed by scientific-production enterprise «Technolit» together with GSTU named after P. O. Sukhoi, launched in the spring of 2015 at the plant «Stroiex» in the city of Chelyabinsk (the Russian Federation. The old cupolas (open type have been replaced by the new cupolas of the closed type, equipped with automatic control and management system and multistage wet gas treatment system. Cupolas are equipped with systems of post-combustion gases and the batch charging, the separate systems of air blast, systems of sludge removal and recirculation of water, the slag granulation installations, mechanized cleaning of cupola furnace and automatic safety system. These activities allowed the company to increase production and improve the quality of cast iron, reduce the coke consumption by 20% and reducing emissions of pollutants into the atmosphere almost 30 times.

  7. Motion correction in MRI of the brain

    Science.gov (United States)

    Godenschweger, F; Kägebein, U; Stucht, D; Yarach, U; Sciarra, A; Yakupov, R; Lüsebrink, F; Schulze, P; Speck, O

    2016-01-01

    Subject motion in MRI is a relevant problem in the daily clinical routine as well as in scientific studies. Since the beginning of clinical use of MRI, many research groups have developed methods to suppress or correct motion artefacts. This review focuses on rigid body motion correction of head and brain MRI and its application in diagnosis and research. It explains the sources and types of motion and related artefacts, classifies and describes existing techniques for motion detection, compensation and correction and lists established and experimental approaches. Retrospective motion correction modifies the MR image data during the reconstruction, while prospective motion correction performs an adaptive update of the data acquisition. Differences, benefits and drawbacks of different motion correction methods are discussed. PMID:26864183

  8. Third degree skin burns caused by a MRI conditional electrocardiographic monitoring system

    Directory of Open Access Journals (Sweden)

    Brix L

    2016-10-01

    Full Text Available Two unusual cases of third degree skin burns are reported using MRI approved electrocardiographic leads. This is very uncommon as it is most often the electrodes which are the source of heat related issues. Both patients were sedated due to pain related issues of their lower spine. The burns were caused by a combination of using a 3 Tesla MRI scanner and the inability to cry out during scanning. We would like to bring forward a message that even when using MRI conditional equipment, clinical staff must be extremely careful in order to secure safe image acquisition using MRI.

  9. Brain MRI in Parkinson's disease

    NARCIS (Netherlands)

    Meijer, F.J.A.; Goraj, B.M.

    2014-01-01

    In this review article, conventional brain MRI and advanced MRI techniques in Parkinson`s disease (PD) are discussed, with emphasis on clinical relevance. Conventional brain MRI sequences generally demonstrate limited abnormalities specific for PD and in clinical practice brain MRI is mainly used to

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  11. Sensitive Equipment Decontamination

    Science.gov (United States)

    2017-10-01

    permeable and porous materials of equipment, such as rubbers, plastic and paints , due to their solvating powers. Such absorption can cause changes to...substrates (e.g., polymers, paints ). TECHNICAL PART STO-TR-HFM-233 3 - 39 N°- Requirement Technical Specifications Capability (efficacy...needed. Environmental aspects Toxicity of nanoparticles has to be studied. Operational parameters Unknown. Shelf-life parameters Depends on

  12. Soviet equipment flies in

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    End of February 1977 a Soviet Ilyushin-76 heavy freight aircraft landed at Cointrin airport having on board fifty large wire proprtional chambers and associated apparatus, together weighing 10 tons, supplied by the Joint Institute for Nuclear Research, Dubna, USSR. The equipment was for the CERN- Dubna-Munich-Saclay experiment NA4 on deep inelastic muon scattering being set up in the North Area of SPS. See Weekly Bulletin 11/78.

  13. Bridges and Equipment

    Science.gov (United States)

    2009-09-15

    the Trilateral Design and Test Code, paragraph 4.2.11, refers to a 15-percent impact factor for bending moment and deflection for crossing vehicle...speeds of 25 km/hr (15 mph). Since the BCS is equipped with both strain and load control features, the impact factor of each vehicle load and speed...can be determined. BCS testing to date has revealed that wheeled vehicle impact factors are approximately 10 percent and tracked vehicle impact

  14. Equipment Obsolescence Management Program

    Energy Technology Data Exchange (ETDEWEB)

    Redmond, J.

    2014-07-01

    Nuclear Power Plant (NPP) Operators are challenged with securing reliable supply channels for safety related equipment due to equipment obsolescence. Many Original Equipment Manufacturers (OEMs) have terminated production of spare parts and product life-cycle support. The average component life cycles are much shorter than the NPP design life, which means that replacement components and parts for the original NPP systems are not available for the complete design life of the NPPs. The lack or scarcity of replacement parts adversely affects plant reliability and ultimately the profitability of the affected NPPs. This problem is further compounded when NPPs pursue license renewal and approval for plant-life extension. A reliable and predictable supply of replacement co components is necessary for NPPs to remain economically competitive and meet regulatory requirements and guidelines. Electrical and I and C components, in particular, have short product life cycles and obsolescence issues must be managed pro actively and not reactively in order to mitigate the risk to the NPP to ensure reliable and economic NPP operation. (Author)

  15. Equipping the stockyard

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-04-01

    Good stockyard management has become an important feature in the coal supply chain. Today, virtually all suppliers and consumers make use of at least one stockyard when moving coal. The type of handling equipment that is best for a particular situation is consequently of wide interest. The value of coal stored in stockpiles can form a significant part of the end user's costs, as pointed out in a recent IEA Coal Research report 'Management of coal stockpiles'. Better blending is becoming a key factor in optimising both power plant and blast furnace performance. It is important to match the materials handling equipment to a facility's needs. Good stockpile management involves processing coal quality within the pile and controlling dust. Decisions must be made on appropriate methods of stacking coal, in longitudinal or circular bed. The article goes on to describe recent contracts for stockyard equipment by such manufacturers as UK-based Strachan and Henshaw and Spain's TAIM TFG. 3 photos.

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... any recent surgeries. Some conditions, such as severe kidney disease, may prevent you from being given gadolinium ... an MRI. If you have a history of kidney disease or liver transplant, it will be necessary ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... also provides movie-like sequential imaging of the cardiovascular system that is important to assess the health ... invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven valuable in diagnosing a ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants ... projectiles within the MRI scanner room and may cause you and/or others nearby harm. These items ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... you should let the radiologist know about them. Parents or family members who accompany patients into the ... intercom. Many MRI centers allow a friend or parent to stay in the room as long as ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... patient to have an allergy to a gadolinium-based contrast agent used for MRI than the iodine- ... For more information on adverse reactions to gadolinium-based contrast agents, please consult the ACR Manual on ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... be removed. MRI exams generally include multiple runs (sequences), some of which may last several minutes. The ... You may be able to relax between imaging sequences, but will be asked to maintain your position ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... to assess the anatomy and function of the heart and its blood flow. Tell your doctor about ... chest cavity, including the mediastinum , chest wall, pleura, heart and vessels, from almost any angle. MRI also ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... you have a history of kidney disease or liver transplant, it will be necessary to perform a blood ... procedure work? Unlike conventional x-ray examinations and computed tomography (CT) scans, MRI does not utilize ionizing radiation. ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... may sense a temporary metallic taste in their mouth after the contrast injection. If you do not ... the iodine-based contrast materials used for conventional x-rays and CT scanning. MRI of the chest is ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want ... in diagnosing a broad range of conditions, including cancer, heart and vascular disease, heart valve abnormalities, bone ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... from the contrast material, including nausea, headache and pain at the site of injection. Similarly, patients are ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... very rare occasions, a few patients experience side effects from the contrast material, including nausea, headache and ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... period is necessary. You may resume your usual activities and normal diet immediately after the exam. On ... that time the imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... to detect and identify any metal objects. In general, metal objects used in orthopedic surgery pose no ... units provide very high quality images for many types of exams. Older open MRI units may not ...

  11. Constrained MRI Impedance Imaging

    National Research Council Canada - National Science Library

    Plewes, Donald

    2002-01-01

    An approach for imaging electric tissue properties in vivo is proposed. The technique relies upon the integration of MRI data with electrical potential measurements made over the surface of the patient...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... you have any devices or metal in your body. Guidelines about eating and drinking before your exam ... soft tissues, bone and virtually all other internal body structures. MRI does not use ionizing radiation (x- ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... devices or metal in your body. Guidelines about eating and drinking before your exam vary between facilities. ... fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... blood flow to the heart) and myocardial infarct (scar in the heart muscle due to prior obstruction ... contrast material except when absolutely necessary for medical treatment. See the MRI Safety page for more information ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI examinations may require you to receive an injection of contrast material into the bloodstream. The radiologist , ... the potential risks. Pregnant women should not receive injections of gadolinium contrast material except when absolutely necessary ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... in the first three to four months of pregnancy unless the potential benefit from the MRI exam is assumed to outweigh the potential risks. Pregnant women should not receive injections of gadolinium ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... for more information. top of page How should I prepare? You may be asked to wear a ... total exam time. top of page What will I experience during and after the procedure? Most MRI ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... surgery pose no risk during MRI. However, a recently placed artificial joint may require the use of ... maintain your position without movement as much as possible. You will usually be alone in the exam ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... activated. Some centers provide earplugs, while others use headphones to reduce the intensity of the sounds made ... Children will be given appropriately sized earplugs or headphones during the exam. MRI scanners are air-conditioned ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI) of the chest uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... by showing them a dummy scanner, play the noises that the child might hear during the MRI ... being imaged, send and receive radio waves, producing signals that are detected by the coils. The electric ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... any recent surgeries. Some conditions, such as severe kidney disease, may prevent you from being given gadolinium contrast ... an MRI. If you have a history of kidney disease or liver transplant, it will be necessary to ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to ... MRI exam, a physician, nurse or technologist will insert an intravenous (IV) catheter, also known as an ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... might hear during the MRI exam, answer any questions and explain the procedure to relieve their anxiety. ... in case the radiologist or technologist has any questions. Some implanted devices require a short period of ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should always ... metal objects. In general, metal objects used in orthopedic surgery pose no risk during MRI. However, a ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... the eyes are particularly important because they may move during the scan, possibly causing blindness. Dyes used in tattoos may contain iron and could heat up during an MRI scan, but this is rare. ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... radiation. MR images of the heart and vascular structures are often clearer and more detailed than with ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... wall, pleura, heart and vessels, from almost any angle. MRI also provides movie-like sequential imaging of ... The images can then be studied from different angles by the interpreting radiologist. Frequently, the differentiation of ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... provides movie-like sequential imaging of the cardiovascular system that is important to assess the health and ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Chest? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... by showing them a dummy scanner, play the noises that the child might hear during the MRI exam, answer any questions and explain the procedure to relieve their anxiety. Some pediatric facilities also provide goggles or headsets ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... scanned and should not enter the MRI scanning area: cochlear (ear) implant some types of clips used ... but they may distort images of the facial area or brain, so you should let the radiologist ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your ... there is any question of their presence, an x-ray may be taken to detect and identify ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... asked to wear a gown. If you have claustrophobia or anxiety, you may want to ask your ... information about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... vary between facilities. Unless you are told otherwise, take your regular medications as usual. Leave jewelry at ... you may follow your regular daily routine and take food and medications as usual. Some MRI examinations ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... Infants and young children usually require sedation or anesthesia to complete an MRI exam without moving. Whether ... A physician or nurse specializing in sedation or anesthesia for children should be available during the exam ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... vessels, from almost any angle. MRI also provides movie-like sequential imaging of the cardiovascular system that ... headsets so that the child can watch a movie while the scan is being performed. Thus, the ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your ... imaging tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... in tattoos may contain iron and could heat up during an MRI scan, but this is rare. ... who will share the results with you. Follow-up examinations may be necessary. Your doctor will explain ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... copied to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed ... physicians with expertise in several radiologic areas. Outside links: For the convenience of our users, RadiologyInfo .org ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... will hear and feel loud tapping or thumping sounds when the coils that generate the radiofrequency pulses ... use headphones to reduce the intensity of the sounds made by the MRI machine. You may be ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  7. Sinus MRI scan

    Science.gov (United States)

    ... tissues surrounding the eye (orbital cellulitis) Nasal polyps Sinusitis -- acute Sinusitis -- chronic Talk to your provider if you have ... therefore is not typically used for suspected acute sinusitis. Alternative Names MRI of the sinuses; Magnetic resonance ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. You will lie ... your skin at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... with claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older ... believed to be caused by the injection of high doses of gadolinium-based contrast material in patients ...

  12. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D. L.; Pichler, B. J.; Gückel, B.

    2015-01-01

    This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from...... February 23 to 27, 2015. Specifically, we summarise the three days of invited presentations from active researchers in this and associated fields augmented by round table discussions and dialogue boards with specific topics. These include the use of PET/MRI in cardiovascular disease, paediatrics, oncology......, neurology and multi-parametric imaging, the latter of which was suggested as a key promoting factor for the wider adoption of integrated PET/MRI. Discussions throughout the workshop and a poll taken on the final day demonstrated that attendees felt more strongly that PET/MRI has further advanced in both...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... body. Guidelines about eating and drinking before your exam vary between facilities. Unless you are told otherwise, ... doctor for a mild sedative prior to the exam. What is MRI of the Chest? What are ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... that the child might hear during the MRI exam, answer any questions and explain the procedure to relieve their anxiety. Some pediatric facilities also provide goggles or headsets ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... by showing them a dummy scanner, play the noises that the child might hear during the MRI ... a noninvasive imaging technique that does not involve exposure to ionizing radiation. MR images of the heart ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam ... Foreign bodies near and especially lodged in the eyes are particularly important because they may move during ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... copied to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... high quality images for many types of exams. Older open MRI units may not provide this same ... You may resume your usual activities and normal diet immediately after the exam. On very rare occasions, ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... ports artificial limbs or metallic joint prostheses implanted nerve stimulators metal pins, screws, plates, stents or surgical ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... patient story here Images × Image Gallery Radiologist preparing patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... prior to your scheduled examination. Infants and young children usually require sedation or anesthesia to complete an MRI exam without moving. Whether a child requires sedation depends on the child's age, intellectual ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that does ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ... time an MRI takes to complete, many young children and infants require sedation to hold still for ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... used in tattoos may contain iron and could heat up during an MRI scan, but this is ... special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI exams is less likely to produce an allergic reaction than the iodine-based contrast materials used for ... There is a very slight risk of an allergic reaction if contrast material is injected. Such reactions are ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... being safe for MRI examinations. Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses implanted nerve stimulators metal pins, screws, plates, ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... your regular medications as usual. Leave jewelry at home and wear loose, comfortable clothing. You may be ... Jewelry and other accessories should be left at home, if possible, or removed prior to the MRI ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... Older open MRI units may not provide this same image quality. Certain types of exams cannot be ... the metallic objects. Patient movement can have the same effect. A very irregular heartbeat may affect the ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ... to iodine or x-ray contrast material, drugs, food, or the environment, or if you have asthma. ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... vs. risks? Benefits MRI is a noninvasive imaging technique that does not involve exposure to ionizing radiation. ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... systemic fibrosis is currently a recognized, but rare, complication of MRI believed to be caused by the ... injection minimizes the risk of this very rare complication. There is a very slight risk of an ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... implanted drug infusion ports artificial limbs or metallic joint prostheses implanted nerve stimulators metal pins, screws, plates, ... risk during MRI. However, a recently placed artificial joint may require the use of another imaging procedure. ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... metal in your body. Guidelines about eating and drinking before your exam vary between facilities. Unless you ... has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with the specific ...

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... of the chest uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... Thus, the child remains motionless allowing for good quality images. Jewelry and other accessories should be left ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or metallic joint prostheses ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... before an MRI exam vary with the specific exam and with the imaging facility. Unless you are told otherwise, you may follow your regular daily routine and take food and medications as usual. ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... have an allergy to a gadolinium-based contrast agent used for MRI than the iodine-containing contrast ... information on adverse reactions to gadolinium-based contrast agents, please consult the ACR Manual on Contrast Media . ...

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... unborn baby will be in a strong magnetic field, pregnant women should not have this exam in the first three to four months of pregnancy unless the potential benefit from the MRI exam is assumed to ...

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... from the contrast material, including nausea, headache and pain at the site of injection. Similarly, patients are ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... take food and medications as usual. Some MRI examinations may require you to receive an injection of ... for a mild sedative prior to your scheduled examination. Infants and young children usually require sedation or ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ... in diagnosing a broad range of conditions, including cancer, heart and vascular disease, heart valve abnormalities, bone ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... the radiofrequency pulses are activated. Some centers provide earplugs, while others use headphones to reduce the intensity ... magnetic environment. Children will be given appropriately sized earplugs or headphones during the exam. MRI scanners are ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available data ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... These items include: jewelry, watches, credit cards and hearing aids, all of which can be damaged pins, ... devices that contain metal may malfunction or cause problems during an MRI exam. Nephrogenic systemic fibrosis is ...

  8. [MRI features of neurosyphilis].

    Science.gov (United States)

    Brisset, M; Chadenat, M L; Cordoliani, Y; Kamga-Tallom, R; D'Anglejean, J; Pico, F

    2011-04-01

    Neurosyphilis is rare today. It arises on average 20 years after poorly treated or untreated primary syphilis. Considering the decline in the incidence of syphilitic meningo encephalitis and the little known MRI aspects, we report the case of a patient affected by neurosyphilis occurring after primary syphilis untreated for 25 years. A 65-year-old man presented typical clinical features including general paresis with psychiatric disorders, maniac access, and frontal syndrome as well as tabes dorsalis and Argyll-Robertson pupil. Brain MRI showed bilateral high intensity signals on the T2 weighted sequence located in mesiotemporal, insular, frontal regions. Very few cases of neurosyphilis with detailed brain MRI aspects have been reported. The interest of this case report is first to recall the importance of syphilitic serology in patients with subacute psychiatric disorders and secondly to present rarely reported aspects of the brain MRI. Copyright © 2011. Published by Elsevier Masson SAS.

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... there is any question of their presence, an x-ray may be taken to detect and identify any ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... your regular daily routine and take food and medications as usual. Some MRI examinations may require you to receive an injection of contrast material into the bloodstream. The radiologist , ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... and may add approximately 15 minutes to the total exam time. top of page What will I ... the limitations of MRI of the Chest? High-quality images are assured only if you are able ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to a digital cloud server. MRI of the chest gives detailed pictures of structures within ...

  13. MRI of intracranial calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jin Wha; Chang, Kee Hyun; Park, Jung Mi; Han, Moon Hee; Han, Man Chung; Kim, Chu Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Recently computed tomography(CT) has been rapidly replaced by magnetic resonance imaging (MRI) in diagnosis of majority of intracranial diseases. But MRI still has some limitation, one of which is its inferiority in detecting calcification. MRI of intracranial calcification has been known to be variable in signal intensity. We retrospectively analyzed the MRI of 26 patients with intracranial calcified lesions in order to evaluate the MR intensity of calcification and to assess the capability of MRI in detecting calcification in various intracranial lesions. All the MRI were obtained using routine T1-and T2-weighted spin eco pulse sequences on 2.0T superconducting system. The 26 patients consisted of 13 brain tumors (4 oligodendrogliomas, 2 craniopharyngiomas, 2 astrocytomas, 1 gem cell tumor, 1 medulloblastoma, 1 ependympma, and pathologically unconfirmed 2 cases), 11 infectious diseases (1 paragonimiasis, 1 sparganosis, 2 cysticercosis, 3 tuberculosis, and 4 unknown cases), and 2 undetermined pathologies. Eighty-two percent (9/11) of infections disease, and 50% (1/2) of undetermined group showed signal diminution or signal void on both T1-and T2-weighted image (T1W1, T2W1). Twenty-four percent (3/13) of brain tumors showed signal diminution on both T1W1 and T2W1. In 46% (6/13) and 61% (8/13) of brain tumors the signal intensities were isointense on T1W1 and T1W1, respectively. Unexpectedly, 3 oligodendrogliomas showed high signal intensity on T1W1, two of which showed com plexed signal intensity mixed with high, iso, and low signal intensities on T2W1. In remained cases (18% (2/11) of infectious diseases and 50% (1/2) of undetermined group) the signal intensities were mixed. With simultaneous review of CT and MRI in each case, the calcification (at least one in cases showing multiple ones) was identifiable on MRI in 62% (8/13) of rumors, 82% (9/11) of infectious diseases, and 100% (2/2) in undetermined group. In 36% (4/11) of infectious diseases, fewer number of

  14. Quantitative rotating frame relaxometry methods in MRI.

    Science.gov (United States)

    Gilani, Irtiza Ali; Sepponen, Raimo

    2016-06-01

    Macromolecular degeneration and biochemical changes in tissue can be quantified using rotating frame relaxometry in MRI. It has been shown in several studies that the rotating frame longitudinal relaxation rate constant (R1ρ ) and the rotating frame transverse relaxation rate constant (R2ρ ) are sensitive biomarkers of phenomena at the cellular level. In this comprehensive review, existing MRI methods for probing the biophysical mechanisms that affect the rotating frame relaxation rates of the tissue (i.e. R1ρ and R2ρ ) are presented. Long acquisition times and high radiofrequency (RF) energy deposition into tissue during the process of spin-locking in rotating frame relaxometry are the major barriers to the establishment of these relaxation contrasts at high magnetic fields. Therefore, clinical applications of R1ρ and R2ρ MRI using on- or off-resonance RF excitation methods remain challenging. Accordingly, this review describes the theoretical and experimental approaches to the design of hard RF pulse cluster- and adiabatic RF pulse-based excitation schemes for accurate and precise measurements of R1ρ and R2ρ . The merits and drawbacks of different MRI acquisition strategies for quantitative relaxation rate measurement in the rotating frame regime are reviewed. In addition, this review summarizes current clinical applications of rotating frame MRI sequences. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D L; Pichler, B J; Gückel, B

    2018-01-01

    The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants c...... of response to pharmacological interventions and therapies. As such, PET/MRI is a key to advancing medicine and patient care....

  16. MRI Physics Workshop:

    OpenAIRE

    Daryoush Saedi

    2009-01-01

    Accurate knowledge of the basic principle of imaging physics helps better understanding of normal anatomy and pathological imaging findings of the diseases."n"n This is more necessary in advanced imaging techniques like MRI because of the complexity of the basic physics of the technique. In basic MRI physics workshop, we discuss about this technique from the primary concepts. The content is very simplified and is showed by slides, animation and easy pictures for better understanding...

  17. MRI of plantar fasciitis

    Energy Technology Data Exchange (ETDEWEB)

    Roger, B.; Grenier, P. [Service de Radiologie Polyvalente Diagnostique et Interventionelle, Hopital de la Pitie, 83, boulevard de l`Hopital, F-75651 Paris Cedex 13 (France)

    1997-12-01

    At present, MRI is the only imaging method that can precisely visualize lesions of the superficial plantar aponeurosis, whether they be musculoaponeurositides, enthesopathies or tears, and whether they be acute or chronic, with or without complications. By its direct visualization of the lesion, MRI enables an accurate assessment of the injury to be made and thereby better orients the therapeutic strategy. (orig.) With 11 figs., 15 refs.

  18. Mauriac syndrome still exists.

    Science.gov (United States)

    Dias, Joana; Martins, Sofia; Carvalho, Susana; Marques, Olinda; Antunes, Ana

    2013-05-01

    Mauriac syndrome (MS) is a rare complication of type 1 diabetes mellitus (DM1). It is related to low insulin concentrations and is less common since longer-acting insulins became available. It is characterized by hepatomegaly, growth and puberty delay, and the presence of elevated transaminases and serum lipids. The aim of this study was to describe the patients from a pediatric diabetic population that fulfill the criteria of MS. A retrospective analysis of the pediatric diabetic population with diagnostic criteria of MS currently followed at Hospital de Braga, was performed. From a population of 91 patients with DM1 18 years, 6 patients with the criteria for MS were identified: 5 girls, and 1 boy. The age at presentation was 13-17 years, with a minimum interval between DM1 diagnosis and MS criteria of 4 years. All the patients were prescribed intensive insulin therapy (median daily insulin dose: 0.88 U/kg). All had a previous history of poor glycemic control before the diagnosis of MS with glycated hemoglobin (HbA1c) between 8.8 and 12.9%. Increase of hepatic enzymes was present in all the patients; 4 of them had associated hepatomegaly. All the girls presented puberty delay and cushingoid features. None of the patients presented short stature and 5 of them presented mixed dyslipidemia. Although MS is an ancient entity described in DM1, it still exists, particularly in adolescent females. Being aware of MS is of extreme importance since most of the clinical features are reversible with better glycemic control. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.

  19. Examining elite Parasport athletes with sport involvement and sports equipment.

    Science.gov (United States)

    Hambrick, Marion E; Hums, Mary A; Bower, Glenna G; Wolff, Eli A

    2015-01-01

    Elite athletes require the most advanced sports equipment to maintain their competitive edge, but manufacturers cannot always satisfy these athletes' specific equipment needs. Sport involvement can influence sports-equipment selections and is described as the process by which individuals rely on attitudes and belief systems to make sports-related consumption decisions. This study involved semistructured interviews with 5 elite Parasport athletes to identify and analyze the role of sport involvement in their selection of sports equipment. The results revealed that the athletes identified product limitations, created a collaborative environment, and promoted a culture of innovation to develop new sports products and address existing limitations. Theoretical and practical implications are discussed.

  20. Highway Maintenance Equipment Operator. Specialized Equipment. Training Materials.

    Science.gov (United States)

    Perky, Sandra Dutreau; And Others

    This curriculum guide provides instructional materials to assist in training equipment operators in the safe and effective use of highway maintenance equipment. It includes 18 units of instruction covering the large equipment used in maintenance operations. Each unit of instruction consists of eight basic components: performance objectives,…

  1. Highway Maintenance Equipment Operator. Miscellaneous Equipment. Training Materials.

    Science.gov (United States)

    Perky, Sandra Dutreau; And Others

    This curriculum guide provides instructional materials to assist in training equipment operators in the safe and effective use of highway maintenance equipment. It includes six units of instruction covering the small, specialized equipment used in maintenance operations. Each unit of instruction consists of eight basic components: performance…

  2. A novel approach to calibrate the hemodynamic model using functional Magnetic Resonance Imaging (fMRI) measurements.

    Science.gov (United States)

    Khoram, Nafiseh; Zayane, Chadia; Djellouli, Rabia; Laleg-Kirati, Taous-Meriem

    2016-03-15

    The calibration of the hemodynamic model that describes changes in blood flow and blood oxygenation during brain activation is a crucial step for successfully monitoring and possibly predicting brain activity. This in turn has the potential to provide diagnosis and treatment of brain diseases in early stages. We propose an efficient numerical procedure for calibrating the hemodynamic model using some fMRI measurements. The proposed solution methodology is a regularized iterative method equipped with a Kalman filtering-type procedure. The Newton component of the proposed method addresses the nonlinear aspect of the problem. The regularization feature is used to ensure the stability of the algorithm. The Kalman filter procedure is incorporated here to address the noise in the data. Numerical results obtained with synthetic data as well as with real fMRI measurements are presented to illustrate the accuracy, robustness to the noise, and the cost-effectiveness of the proposed method. We present numerical results that clearly demonstrate that the proposed method outperforms the Cubature Kalman Filter (CKF), one of the most prominent existing numerical methods. We have designed an iterative numerical technique, called the TNM-CKF algorithm, for calibrating the mathematical model that describes the single-event related brain response when fMRI measurements are given. The method appears to be highly accurate and effective in reconstructing the BOLD signal even when the measurements are tainted with high noise level (as high as 30%). Published by Elsevier B.V.

  3. Methodology for assessing laser-based equipment

    Science.gov (United States)

    Pelegrina-Bonilla, Gabriel; Hermsdorf, Jörg; Thombansen, Ulrich; Abels, Peter; Kaierle, Stefan; Neumann, Jörg

    2017-10-01

    Methodologies for the assessment of technology's maturity are widely used in industry and research. Probably the best known are technology readiness levels (TRLs), initially pioneered by the National Aeronautics and Space Administration (NASA). At the beginning, only descriptively defined TRLs existed, but over time, automated assessment techniques in the form of questionnaires emerged in order to determine TRLs. Originally TRLs targeted equipment for space applications, but the demands on industrial relevant equipment are partly different in terms of, for example, overall costs, product quantities, or the presence of competitors. Therefore, we present a commonly valid assessment methodology with the aim of assessing laser-based equipment for industrial use, in general. The assessment is carried out with the help of a questionnaire, which allows for a user-friendly and easy accessible way to monitor the progress from the lab-proven state to the application-ready product throughout the complete development period. The assessment result is presented in a multidimensional metric in order to reveal the current specific strengths and weaknesses of the equipment development process, which can be used to direct the remaining development process of the equipment in the right direction.

  4. Californium-252 Program Equipment Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chattin, Fred Rhea [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Kenton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ezold, Julie G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-12-01

    To successfully continue the 252Cf production and meet the needs of the customers, a comprehensive evaluation of the Building 7920 processing equipment was requested to identify equipment critical to the operational continuity of the program.

  5. Realistic analytical polyhedral MRI phantoms.

    Science.gov (United States)

    Ngo, Tri M; Fung, George S K; Han, Shuo; Chen, Min; Prince, Jerry L; Tsui, Benjamin M W; McVeigh, Elliot R; Herzka, Daniel A

    2016-08-01

    Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing three-dimensional (3D) analytical phantoms are unable to accurately model shapes of biomedical interest. The goal of this study was to demonstrate that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedical shapes. The Fourier transform of a polyhedron was implemented and its accuracy in representing faceted and smooth surfaces was characterized. Realistic anthropomorphic polyhedral brain and torso phantoms were constructed and their use in simulated 3D and two-dimensional (2D) MRI acquisitions was described. Using polyhedra, the Fourier transform of faceted shapes can be computed to within machine precision. Smooth surfaces can be approximated with increasing accuracy by increasing the number of facets in the polyhedron; the additional accumulated numerical imprecision of the Fourier transform of polyhedra with many faces remained small. Simulations of 3D and 2D brain and 2D torso cine acquisitions produced realistic reconstructions free of high frequency edge aliasing compared with equivalent voxelized/rasterized phantoms. Analytical polyhedral phantoms are easy to construct and can accurately simulate shapes of biomedical interest. Magn Reson Med 76:663-678, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  6. Simulated field maps for susceptibility artefact correction in interventional MRI.

    Science.gov (United States)

    Kochan, Martin; Daga, Pankaj; Burgos, Ninon; White, Mark; Cardoso, M Jorge; Mancini, Laura; Winston, Gavin P; McEvoy, Andrew W; Thornton, John; Yousry, Tarek; Duncan, John S; Stoyanov, Danail; Ourselin, Sébastien

    2015-09-01

    Intraoperative MRI (iMRI) is a powerful modality for acquiring images of the brain to facilitate precise image-guided neurosurgery. Diffusion-weighted MRI (DW-MRI) provides critical information about location, orientation and structure of nerve fibre tracts, but suffers from the "susceptibility artefact" stemming from magnetic field perturbations due to the step change in magnetic susceptibility at air-tissue boundaries in the head. An existing approach to correcting the artefact is to acquire a field map by means of an additional MRI scan. However, to recover true field maps from the acquired field maps near air-tissue boundaries is challenging, and acquired field maps are unavailable in historical MRI data sets. This paper reports a detailed account of our method to simulate field maps from structural MRI scans that was first presented at IPCAI 2014 and provides a thorough experimental and analysis section to quantitatively validate our technique. We perform automatic air-tissue segmentation of intraoperative MRI scans, feed the segmentation into a field map simulation step and apply the acquired and the simulated field maps to correct DW-MRI data sets. We report results for 12 patient data sets acquired during anterior temporal lobe resection surgery for the surgical management of focal epilepsy. We find a close agreement between acquired and simulated field maps and observe a statistically significant reduction in the susceptibility artefact in DW-MRI data sets corrected using simulated field maps in the vicinity of the resection. The artefact reduction obtained using acquired field maps remains better than that using the simulated field maps in all evaluated regions of the brain. The proposed simulated field maps facilitate susceptibility artefact reduction near the resection. Accurate air-tissue segmentation is key to achieving accurate simulation. The proposed simulation approach is adaptable to different iMRI and neurosurgical applications.

  7. MRI of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Kauczor, Hans-Ulrich (ed.) [University Clinic Heidelberg (Germany). Diagnostic and Interventional Radiology

    2009-07-01

    For a long time, only chest X-ray and CT were used to image lung structure, while nuclear medicine was employed to assess lung function. During the past decade significant developments have been achieved in the field of magnetic resonance imaging (MRI), enabling MRI to enter the clinical arena of chest imaging. Standard protocols can now be implemented on up-to-date scanners, allowing MRI to be used as a first-line imaging modality for various lung diseases, including cystic fibrosis, pulmonary hypertension and even lung cancer. The diagnostic benefits stem from the ability of MRI to visualize changes in lung structure while simultaneously imaging different aspects of lung function, such as perfusion, respiratory motion, ventilation and gas exchange. On this basis, novel quantitative surrogates for lung function can be obtained. This book provides a comprehensive overview of how to use MRI for imaging of lung disease. Special emphasis is placed on benign diseases requiring regular monitoring, given that it is patients with these diseases who derive the greatest benefit from the avoidance of ionizing radiation. (orig.)

  8. MRI in Japanese encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S. [Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India). Dept. of Radiology; Misra, U.K. [Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India). Dept. of Neurology; Kalita, J. [Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India). Dept. of Neurology; Salwani, V. [Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India). Dept. of Radiology; Gupta, R.K. [Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India). Dept. of Radiology; Gujral, R. [Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India). Dept. of Radiology

    1997-03-01

    We document the MRI features in seven patients with Japanese encephalitis. MRI was carried out on a 1.5 T system within 10-60 days of onset. In all the patients MRI revealed bilateral thalamic lesions, haemorrhagic in five. Signal changes were present in the cerebrum in four patients, the midbrain and cerebellum in three each, the pons in two and the basal ganglia in one. The lesions were haemorrhagic in three of the four patients with lesions in the cortex, two of the three with lesions in the midbrain and cerebellum, but the pontine lesions were haemorrhagic in both patients. Spinal cord involvement was seen in one of the three patients who underwent MRI. In two patients MRI was repeated 3 years after the onset, showing marked reduction in abnormal signal; and all the lesions gave low signal on both T1- and T2-weighted images. Bilateral thalamic involvement, especially haemorrhagic, may be considered characteristic of Japanese encephalitis, especially in endemic areas. (orig.)

  9. MRI-visible pericochlear lesions in osteogenesis imperfecta type I

    Energy Technology Data Exchange (ETDEWEB)

    Ziyeh, S.; Berger, R.; Reisner, K. [Radiologische Klinik, St. Vincentiuskrankenhaeuser, Karlsruhe (Germany)

    2000-10-01

    Osteogenesis imperfecta (OI) is an inherited generalized disorder of type-I collagen synthesis often associated with hearing loss. We present a case of OI type I in which hearing loss led to examination of the temporal bone with MRI. In the osseous otic capsule MRI demonstrated pericochlear lesions with soft tissue signal intensity and contrast enhancement. Changes similar to otosclerosis have been described in the temporal bone of OI patients when applying CT, but reports on MRI findings do not yet exist. (orig.)

  10. [MRI for myocarditis].

    Science.gov (United States)

    Gutberlet, M; Lücke, C; Krieghoff, C; Hildebrand, L; Lurz, P; Steiner, J; Adam, J; Eitel, I; Thiele, H; Grothoff, M; Grotthoff, M; Lehmkuhl, L

    2013-01-01

    Cardiovascular magnetic resonance imaging (CMRI) has become the primary tool for the non-invasive assessment in patients with suspected myocarditis, especially after exclusion of acute coronary syndrome (ACS) for the differential diagnosis. Various MRI parameters are available which have different accuracies. Volumetric and functional ventricular assessment and the occurrence of pericardial effusion alone demonstrate only a poor sensitivity and specificity. The calculation of the T2-ratio (edema assessment), the early or global relative myocardial enhancement (gRE) and the late gadolinium enhancement (LGE), which represents irreversibly injured myocardium, are more specific parameters. All MRI parameters demonstrate the best accuracy in infarct-like acute myocarditis, whereas in chronic myocarditis sensitivity and specificity are less accurate. Therefore, a multisequential (at least two out of three parameters are positive) approach is recommended. The assessment of the value of newer, more quantitative MRI sequences, such as T1 and T2-mapping is still under investigation.

  11. MRI Conditional Pacemakers

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2014-10-01

    Full Text Available Conventionally, magnetic resonance [MR] imaging is an absolute contraindication for those with an implanted pacemaker.This represents a significant clinical problem as several studies have shown approximately 75% of patients with pacemakers will have an indication for an MRI scan. Patients over the age of 65 are twice as likely to require an MRI and 80% of pacemaker patients are over the age of 65. MR imaging is an important source of information for neurological disorders and several soft tissue abnormalities. Hence denying this important diagnostic modality for those with an implanted pacemaker and other cardiac implantable electronic devices [CIED] is a tremendous clinical problem both because of concerns about MRI signals interfering with the function of the pacemaker and the pacemaker in turn interfering with the MR images.

  12. MRI of oriental cholangiohepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Wani, N.A., E-mail: ahmad77chinar@gmail.co [Department of Radiodiagnosis and Imaging, Sher-I-Kashmir Institute of Medical Sciences (SKIMS), Srinagar (India); Robbani, I.; Kosar, T. [Department of Radiodiagnosis and Imaging, Sher-I-Kashmir Institute of Medical Sciences (SKIMS), Srinagar (India)

    2011-02-15

    Oriental cholangiohepatitis (OCH) also called recurrent pyogenic cholangitis is characterized by intrahepatic duct calculi, strictures, and recurrent infections. In turn cholangitis can result in multiple hepatic abscesses, further biliary strictures, and in severe cases, progressive hepatic parenchymal destruction, cirrhosis, and portal hypertension. Magnetic resonance cholangiopancreatography (MRCP) and conventional T1-weighted (T1 W) and T2-weighted (T2 W) magnetic resonance imaging (MRI) findings have been described in patients with OCH. MRCP findings include duct dilation, strictures, and calculi. MRCP can help to localize the diseased ducts and determine the severity of involvement. T1 and T2 W sequences reveal the parenchymal changes of atrophy, abscess formation, and portal hypertension in addition to calculi. Post-treatment changes are also well depicted using MRI. Comprehensive, non-invasive assessment is achieved by using conventional MRI and MRCP in OCH providing a roadmap for endoscopic or surgical management.

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ... Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association top ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... You may resume your usual activities and normal diet immediately after the exam. On very rare occasions, ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ... can help physicians evaluate the structures of the brain and can also provide functional information (fMRI) in ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce ...

  17. Quality assurance in functional MRI

    DEFF Research Database (Denmark)

    Liu, Thomas T; Glover, Gary H; Mueller, Bryon A

    2015-01-01

    Over the past 20 years, functional magnetic resonance imaging (fMRI) has ben- efited greatly from improvements in MRI hardware and software. At the same time, fMRI researchers have pushed the technical limits of MRI systems and greatly in- fluenced the development of state-of-the-art systems....... Minimizing image noise and maximizing system stability is critical in fMRI because the blood oxygenation level- dependent (BOLD) signal changes that are used for most fMRI studies represent only a small fraction of the total MR signal. In addition, multiple imaging volumes must be acquired over time to track...... cognitive processes. As a result, MRI scanners must have excellent time-series stability to accurately measure BOLD signal changes over the course of a long time series (typically on the order of 10 min per scan). fMRI studies are particularly demanding on the scanner hardware because they utilize fast...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... may not fit into the opening of certain types of MRI machines. The presence of an implant ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... affecting the MRI images, these objects can become projectiles within the MRI scanner room and may cause ... at a very early stage by mapping the motion of water molecules in the tissue. This water ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... treatment. See the MRI Safety page for more information about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your physician for ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have a personal story about radiology? Share your patient story here Images ... (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a very small chance of irritation of your skin at the site of the IV tube insertion. ... detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. MRI ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... ionizing radiation. MRI can help physicians evaluate the structures of the brain and can also provide functional ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging test ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that ... than 30 minutes from the onset of symptoms. Risks The MRI examination poses almost no risk to ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. MRI ... the technologist or nurse will monitor your vital signs to minimize this risk. Although the strong magnetic ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... women should not have this exam in the first three to four months of pregnancy unless the ... not to have an MRI exam during the first trimester unless medically necessary. MRI may not always ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. MRI enables the ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... copied to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... claustrophobia. Newer open MRI units provide very high quality images for many types of exams. Older open MRI units may not provide this same image quality. Certain types of exams cannot be performed using ...

  15. Getting an MRI (For Kids)

    Science.gov (United States)

    ... Weight for Me? What Is an Intellectual Disability? Movie: Endocrine System Getting an MRI ... MRI (magnetic resonance imaging) scan creates detailed pictures of the inside of the body. The test is painless. All you'll need ...

  16. Getting an MRI (For Kids)

    Medline Plus

    Full Text Available ... Weight for Me? What Is an Intellectual Disability? Movie: Endocrine System Getting an MRI ... MRI (magnetic resonance imaging) scan creates detailed pictures of the inside of the body. The test is painless. All you'll need ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... devices require a short period of time after placement (usually six weeks) before being safe for MRI ... devices that contain metal may malfunction or cause problems during an MRI exam. Nephrogenic systemic fibrosis is ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... This detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. ... information. MRI can detect stroke at a very early stage by mapping the motion of water molecules ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... MRI. For more information, consult your radiologist. The computer workstation that processes the imaging information is located ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ... early diagnosis and evaluation of many conditions, including tumors. MRI enables the discovery of abnormalities that might ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... does not completely surround you. Some newer MRI machines have a larger diameter bore which can be ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ...

  4. 21 CFR 866.4520 - Immunofluorometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4520 Immunofluorometer equipment. (a) Identification. Immunofluorometer equipment for clinical use with...

  5. Getting an MRI (For Kids)

    Medline Plus

    Full Text Available ... Cliques Make Kids Feel Left Out Getting an MRI (Video) KidsHealth > For Kids > Getting an MRI (Video) Print A A A en español Obtención de una resonancia magnética, RM (video) An MRI (magnetic resonance imaging) scan creates detailed pictures of ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits MRI is a noninvasive imaging technique that does not involve exposure to ionizing radiation. MRI can help physicians evaluate the structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of the ...

  7. Getting an MRI (For Kids)

    Medline Plus

    Full Text Available ... Go to School? Breast Cancer Getting an MRI (Video) KidsHealth > For Kids > Getting an MRI (Video) Print A A A en español Obtención de una resonancia magnética, RM (video) An MRI (magnetic resonance imaging) scan creates detailed ...

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... have allergies of any kind, such as an allergy to iodine or x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material most commonly used for an MRI exam contains a ... patients with iodine contrast allergy. It is far less common for a patient ...

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  10. MRI in suspected appendicitis

    NARCIS (Netherlands)

    Leeuwenburgh, M.M.N.

    2014-01-01

    Dit proefschrift richt zich op de optimalisatie van beeldvormende diagnostiek bij patiënten met een klinische verdenking op appendicitis, waarbij het gebruik van ‘magnetic resonance imaging’ (MRI) wordt verkend. Het proefschrift omvat de resultaten van de OPTIMAP-studie (OPTimisation of IMaging

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... MRI. If you have a history of kidney disease or liver transplant, it will be necessary to perform a blood test to determine whether the kidneys are functioning ... and vascular disease, heart valve abnormalities, bone and other soft tissue ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... with the magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... into the scanning room also need to remove metal objects and notify the technologist of any medical or electronic devices they may have. top of page What ...

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... exam time. top of page What will I experience during and after the procedure? Most MRI exams ... areas. Outside links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo. ...

  14. MRI in decompression illness

    Energy Technology Data Exchange (ETDEWEB)

    Hierholzer, J.; Stroszczynski, C.; Hosten, N.; Felix, R. [Dept. of Radiology, Charite Campus Virchow-Klinikum, Humboldt Univ. Berlin (Germany); Tempka, A. [Dept. of Traumatology, Charite Campus Virchow-Klinikum, Humboldt Univ. Berlin (Germany); Amodio, F. [Dept. of Radiology, Univ. Federico II di Napoli, Naples (Italy); Haas, J. [Dept. of Neurology, Juedisches Krankenhaus Berlin, Berlin (Germany)

    2000-05-01

    We report a case of decompression illness in which the patient developed paraparesis during scuba diving after rapid ascent. MRI of the spine revealed a focal intramedullary lesion consistent with the symptoms. The pathophysiological and radiological aspects of spinal decompression illness are discussed. (orig.)

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please consult the ACR Manual on Contrast Media and its references. top of page What are the limitations of MRI of the Chest? High-quality images are assured only if you are able ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... sedation or anesthesia. Alternatively, certain pediatric facilities have child life personnel who can work with younger children to help avoid the need for sedation or anesthesia. They prepare the children ... play the noises that the child might hear during the MRI exam, answer any ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... it difficult to lie still during imaging. A person who is very large may not fit into the opening of certain types of MRI machines. The presence of an implant or other metallic object sometimes makes it difficult to obtain clear images due to ...

  18. MRI of the Chest

    Medline Plus

    Full Text Available ... devices or metal in your body. Guidelines about eating and drinking before your exam vary between facilities. Unless you ... fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with the specific ...

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... patients with iodine contrast allergy. It is far less common for a patient to have an allergy to ... The contrast material used in MRI exams is less likely to produce an allergic reaction than the iodine-based contrast materials used for ...

  20. MRI and Anesthesia & Sedation

    Directory of Open Access Journals (Sweden)

    Asim Esen

    2017-08-01

    Full Text Available In 1945 Broch & Purcell described as Nuclear Magnetic Resonance. It wasused for chemical and biochemical analyses for long years. It was widelyused in medical applications after Lauterbur et al. ‘s study in 1973 (1.The primary screening method for breast cancer is mammography asknown. It is the only method that positively affects survival. But itssensitivity and specificity is not 100% and it can be an inadequate methodat some ages. Studies showed that: MRI imaging added mammographyincreased success rates but increased false positivity rates can cause someunnecessary invasive procedures. Although these breast MRI is widely usedfor screening, diagnosis and staging (2.More than 80 million MRI is worldwide applied yearly. Claustrophobia ratesare between 1-15% and more than 2 million breast MRI application isinterrupted for the necessitation of sedation (3. Melendez et al. noticedthat rate around 30%. Also 3-5% of these cases were interrupted due tothe sedation necessitation. Anxiety and claustrophobia can cause sequencerepeating, procedure cancellation and important time and labor loss.

  1. MRI of the Chest

    Medline Plus

    Full Text Available ... complete an MRI exam without moving. Whether a child requires sedation depends on the child's age, intellectual development and the type of exam. ... should be available during the exam for your child's safety. You will be given special instructions for ...

  2. MRI of the Chest

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... bear denotes child-specific content. Related Articles and Media MR ... Images related to Magnetic Resonance Imaging (MRI) - Chest Sponsored ...

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will be necessary to perform a blood test to determine whether the kidneys are ... including cancer, heart and vascular disease, heart valve abnormalities, bone ...

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... imaging (MRI) of the chest uses a powerful magnetic field, radio waves and a computer to produce detailed ... whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  5. Human developmental anatomy: microscopic magnetic resonance imaging (μMRI) of four human embryos (from Carnegie Stage 10 to 20).

    Science.gov (United States)

    Lhuaire, Martin; Martinez, Agathe; Kaplan, Hervé; Nuzillard, Jean-Marc; Renard, Yohann; Tonnelet, Romain; Braun, Marc; Avisse, Claude; Labrousse, Marc

    2014-12-01

    Technological advances in the field of biological imaging now allow multi-modal studies of human embryo anatomy. The aim of this study was to assess the high magnetic field μMRI feasibility in the study of small human embryos (less than 21mm crown-rump) as a new tool for the study of human descriptive embryology and to determine better sequence characteristics to obtain higher spatial resolution and higher signal/noise ratio. Morphological study of four human embryos belonging to the historical collection of the Department of Anatomy in the Faculty of Medicine of Reims was undertaken by μMRI. These embryos had, successively, crown-rump lengths of 3mm (Carnegie Stage, CS 10), 12mm (CS 16), 17mm (CS 18) and 21mm (CS 20). Acquisition of images was performed using a vertical nuclear magnetic resonance spectrometer, a Bruker Avance III, 500MHz, 11.7T equipped for imaging. All images were acquired using 2D (transverse, sagittal and coronal) and 3D sequences, either T1-weighted or T2-weighted. Spatial resolution between 24 and 70μm/pixel allowed clear visualization of all anatomical structures of the embryos. The study of human embryos μMRI has already been reported in the literature and a few atlases exist for educational purposes. However, to our knowledge, descriptive or morphological studies of human developmental anatomy based on data collected these few μMRI studies of human embryos are rare. This morphological noninvasive imaging method coupled with other techniques already reported seems to offer new perspectives to descriptive studies of human embryology.

  6. MRI of the cardiomyopathies

    Energy Technology Data Exchange (ETDEWEB)

    Di Cesare, Ernesto E-mail: ernesto.dicesare@cc.univaq.it

    2001-06-01

    We examined the potentialities of Magnetic resonance imaging (MRI) in the evaluation of the main cardiomyopathies: hypertrophic, dilated, restrictive and arrhythmogenic right ventricular. The hypertrophic cardiomyopathy is generally adequately investigated by echocardiography, that well defines the myocardial thickening and the obstruction of the left ventricular output. However, by echocardiography we still have difficulties in the evaluation of the apex of the left ventricle and the right ventricle involvement. MRI provides a complete evaluation of the heart with a clear evidence also of the echocardiographic dark zones by means of a clear evidence of the apex of the right ventricle. The dilated form is also well investigated by MRI that provides a clear evaluation of the volumes, mass and ejection fraction by means of the 3D analysis including conditions of the ventricular remodelling. Moreover, this technique helps in the differential diagnosis of acute myocarditis. In the acute phase of myocarditis (first 2 weeks), in fact, the myocardium produces high signal intensity on the T2 weighted sequences due to the presence of oedema. The third form of cardiomyopathy is the restrictive one, characterised by reduced diastolic filling and diastolic volume, normality of the systolic function and parietal thickness, interstitial fibrosis and enlargement of both atria. The mean potentiality of MRI is related to the differential diagnosis with constrictive pericarditis. Only in the former, the pericardium appears irregularly thickened with areas exceeding 4 mm of pericardial thickness. Finally, the right ventricular arrhythmogenic cardiomyopathy represents the main indication to MRI evaluation. With this imaging modality we are can obtain a clear morpho-functional evaluation of the right ventricle and distinguish the intramyocardial adipose substitution characterised by areas of high signal in the myocardium.

  7. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  8. Negotiating optimum capital equipment acquisitions.

    Science.gov (United States)

    Pols, A L

    1999-06-01

    Healthcare organizations planning capital equipment acquisitions should negotiate with more than one equipment vendor and determine the equipment purchase price, service agreement price, and financing or leasing option rate separately to avoid hidden costs. The purchase price should be negotiated first. A long-term service agreement should be locked in, or service insurance purchased, for the length of the financing or lease agreement. The equipment vendor's financing agreement should be compared with offers from third parties, who may have more beneficial financing options or more flexible lease arrangements.

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... is based on clinical judgment. This is because traction devices and many types of life support equipment ... Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological Society of North America, ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... for immediate assistance. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ... because traction devices and many types of life support equipment may distort the MR images and as ...

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... or anesthesia. Alternatively, certain pediatric facilities have child life personnel who can work with younger children to ... is because traction devices and many types of life support equipment may distort the MR images and ...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... patients who have been acutely injured; however, this decision is based on clinical judgment. This is because traction devices and many types of life support equipment may distort the MR images and as ...

  13. Existence and Detection of Fireballs,

    Science.gov (United States)

    An attempt is made to analyze critically the experimental proofs indicating the existence of fireballs. Some ideas are presented on methods of the...properties of fireballs if their existence will be checked by other methods. (Author)

  14. High Pressure Processing Technology and Equipment Evolution: A Review

    Directory of Open Access Journals (Sweden)

    Wael M. Elamin

    2015-12-01

    Full Text Available High pressure processing (HPP is an interesting non-thermal technology that involves the sterilization of food by the mean of ultra-high pressures, which lead to extending the shelf life of processed food, as well as maintaining nutritional value and quality of food products. The consumers’ increasing demand for this new products graped the interest of several already-existing high pressure equipment manufacturers around the globe. The successful of this technology encouraged them to enter the field of food processing and adjust their existing technologies to adapt to the new process. This review spots the major discoveries in HPP equipment history, describes the current applications of HHP in processing and provides comprehensive information about HPP equipment technology used in commercial and research applications. In addition, this paper presents the major manufacturers in HPP equipment industry around the world.

  15. Brain MRI in Parkinson's disease.

    Science.gov (United States)

    Meijer, Frederick J A; Goraj, Bozena

    2014-06-01

    In this review article, conventional brain MRI and advanced MRI techniques in Parkinson`s disease (PD) are discussed, with emphasis on clinical relevance. Conventional brain MRI sequences generally demonstrate limited abnormalities specific for PD and in clinical practice brain MRI is mainly used to exclude other pathology. Possibly, brain MRI at higher magnetic field strengths could provide new diagnostic markers. In recent years, new imaging techniques such as susceptibility weighted imaging (SWI), diffusion (tensor) MRI, magnetization transfer imaging (MTI), and functional MRI (f-MRI) have been applied to patient cohorts with PD to improve understanding of pathophysiologic changes, including functional connectivity. These advanced MRI techniques hold promise to provide additional diagnostic markers for early stage PD, as demonstrated by diffusional changes in the orbital-frontal region in the pre-motor phase of PD. Whether these advanced MRI techniques provide new diagnostic markers for early stage PD, remains a debate. Standardization of scanning protocols and post-processing methods, and validation of diagnostic criteria is crucial for these advanced MRI techniques. For this, well designed prospective clinical cohort studies are needed.

  16. Improvement of an existing low cost wooden groundnut sheller ...

    African Journals Online (AJOL)

    An existing manually operated groundnut sheller was re-designed, fabricated and tested. About 90% of the components of the 18 kg./hr capacity rasp-bar sheller, equipped with a kernelcleaning device, were fabricated using the sawn wood of Cordia millennii. A one-off prototype of the sheller was produced at a total cost of ...

  17. The physics of MRI safety.

    Science.gov (United States)

    Panych, Lawrence P; Madore, Bruno

    2018-01-01

    The main risks associated with magnetic resonance imaging (MRI) have been extensively reported and studied; for example, everyday objects may turn into projectiles, energy deposition can cause burns, varying fields can induce nerve stimulation, and loud noises can lead to auditory loss. The present review article is geared toward providing intuition about the physical mechanisms that give rise to these risks. On the one hand, excellent literature already exists on the practical aspect of risk management, with clinical workflow and recommendations. On the other hand, excellent technical articles also exist that explain these risks from basic principles of electromagnetism. We felt that an underserved niche might be found between the two, ie, somewhere between basic science and practical advice, to help develop intuition about electromagnetism that might prove of practical value when working around MR scanners. Following a wide-ranging introduction, risks originating from the main magnetic field, the excitation RF electromagnetic field, and switching of the imaging gradients will be presented in turn. 5 Technical Efficacy: 1 J. Magn. Reson. Imaging 2018;47:28-43. © 2017 International Society for Magnetic Resonance in Medicine.

  18. 23 CFR 140.910 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Equipment. 140.910 Section 140.910 Highways FEDERAL... Railroad Work § 140.910 Equipment. (a) Company owned equipment. Cost of company-owned equipment may be... equipment. Where company owned equipment is not available, reimbursement will be limited to the amount of...

  19. Food Service Equipment and Appurtenances.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    Equipment design specifications are presented relating to tables of all kinds, counters, sinks and drainboards, bins, shelves, drawers, hoods and similar kitchen appurtenances, not including baking, roasting, toasting, broiling or frying equipment, food preparation machinery such as slicers, choppers, and cutters, mixers and grinders, steam…

  20. MRI criteria for MS in patients with clinically isolated syndromes

    DEFF Research Database (Denmark)

    Montalban, X.; Tintore, M.; Swanton, J.

    2010-01-01

    In recent years, criteria for the diagnosis of multiple sclerosis (MS) have changed, mainly due to the incorporation of new MRI criteria. While the new criteria are a logical step forward, they are complex and-not surprisingly-a good working knowledge of them is not always evident among...... neurologists and neuroradiologists. In some circumstances, several MRI examinations are needed to achieve an accurate and prompt diagnosis. This provides an incentive for continued efforts to refine the incorporation of MRI-derived information into the diagnostic workup of patients presenting with a clinically...... isolated syndrome. Within the European multicenter collaborative research network that studies MRI in MS (MAGNIMS), a workshop was held in London in November 2007 to review information that may simplify the existing MS diagnostic criteria, while maintaining a high specificity that is essential to minimize...

  1. The fMRI signal, slow cortical potential and consciousness.

    Science.gov (United States)

    He, Biyu J; Raichle, Marcus E

    2009-07-01

    As functional magnetic resonance imaging (fMRI) has become a driving force in cognitive neuroscience, it is crucial to understand the neural basis of the fMRI signal. Here, we discuss a novel neurophysiological correlate of the fMRI signal, the slow cortical potential (SCP), which also seems to modulate the power of higher-frequency activity, the more established neurophysiological correlate of the fMRI signal. We further propose a hypothesis for the involvement of the SCP in the emergence of consciousness, and review existing data that lend support to our proposal. This hypothesis, unlike several previous theories of consciousness, is firmly rooted in physiology and as such is entirely amenable to empirical testing.

  2. Information technology equipment cooling method

    Science.gov (United States)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  3. MRI of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Vahlensieck, M.

    2000-02-01

    Shoulder imaging is one of the major applications in musculoskeletal MRI. In order to analyze the images it is important to keep informed about anatomical and pathological findings and publications. In this article MRI technique, anatomy and pathology is reviewed. Technical considerations about MR sequences and examination strategy are only shortly discussed with emphasis on turbo spin echo and short T1 inversion recovery imaging. Basic anatomy as well as recent findings, including macroscopic aspects of the supraspinatus fat pad, composition of the supraspinatus muscle belly, and variability of the glenohumeral ligaments or coracoid ligament, are presented. Basic pathological conditions are described in detail, e. g. instability particularly problems in differentiating the various subtypes of labral pathology. Rotator cuff diseases are elucidated with emphasis on some rarer entities such as subscapularis calcifying tendinitis, coracoid impingement, chronic bursitis producing the double-line sign, prominent coraco-acromial ligament and the impingement due to an inflamed os acromiale. (orig.)

  4. Equipe de trabalho

    Directory of Open Access Journals (Sweden)

    Gabriel Gerber Hornink

    2014-08-01

    Full Text Available   Equipe de Trabalho 2014 1. Equipe editorial Editor-Chefe Bayardo Bapstista Torres, Instituto de Química - USP, Brasil Eduardo Galembeck, Departamento de Bioquímica Instituto de Biologia UNICAMP, Brasil   Editores Gabriel Gerber Hornink, Depto. Bioquímica, Instituto de Ciências Biomédicas, Universidade - Federal de Alfenas - Unifal-MG, Brasil Vera Maria Treis Trindade, Instituto de Ciências Básicas da Saúde, Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, Brasil   Corpo Editorial Adriana Cassina, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Angel Herráez, Departamento de Bioquímica y Biología molecular, Universidad de Alcalá de Henares, Madrid, Espanha André Amaral Gonçalves Bianco, Universidade Federal de São Paulo (Unifesp, Brasil Denise Vaz de Macedo, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Eneida de Paula, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Guilherme Andrade Marson, Instituto de Química - USP, Brasil Jose Antonio Martinez Oyanedel, Universidad de Concepción, Chile Josep Maria Fernández Novell, Dept. Bioquímica i Biologia Molecular Universitat de Barcelona, Espanha Leila Maria Beltramini, Instituto de Física de São Carlos, Universidade Estadual de São Paulo - USP, Brasil Manuel João da Costa, Escola de Ciências da Saúde, Universidade do Minho, Portugal Maria Lucia Bianconi, Instituto de Bioquímica Médica Universidade Federal do Rio de Janeiro (UFRJ, Brasil María Noel Alvarez, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Miguel Ángel Medina Torres, Department of Molecular Biology & Biochemistry Faculty of Sciences University of Málaga, Espanha Nelma Regina Segnini Bossolan, Instituto de Física de São Carlos, Universidade de São Paulo - USP, Brasil Paulo De Avila

  5. Introduction to MRI Physics.

    Science.gov (United States)

    Martinez, Gary V

    2018-01-01

    Magnetic resonance imaging (MRI) is an imaging technique derived from radiofrequency (RF) signals of proton that are magnetized by a strong magnetic field. These protons typically originate from water, fat, or metabolites. The application of RF pulses is used to excite the magnetization, whereas pulsed magnetic field gradients are used to provide spatial localization. This chapter describes the fundamental principles giving rise to MR images. Furthermore, the connection between relaxation and image contrast is discussed.

  6. Development of a new visual stimulation device for functional MRI using image guides

    Energy Technology Data Exchange (ETDEWEB)

    Nishida, Yasuhiro; Hayashi, Osamu; Iwami, Tatsuya; Kani, Kazutaka; Ito, Ryuta [Shiga Univ. of Medical Science, Otsu (Japan)

    1999-12-01

    Functional magnetic resonance imaging (fMRI) makes it possible to detect the center of the neuronal activity in the brain without any damages to the human body. Although fMRI is also popularly employed in ophthalmology, it is sometimes impossible to give the subject optimal visual stimulation. The space inside MRI equipment is small and has a high magnetic field, so it is very difficult to put a visual stimulation device inside. To resolve these problems, we developed a new visual stimulation device for fMRI. This device consists of two sets of image guides, liquid crystal projectors, C mounted cameras, and an eyepiece. The image guides and the eyepiece are diamagnetic, so they can be installed on the surface or head coil of the MRI equipment without any magnetic influence on the fMRI. The images in each eyepiece are separated, so it becomes possible to easily give a binocular parallax stimulation. This device will be very useful for the fMRI investigations concerning the visual center in the brain. (author)

  7. Kierkegaardovo pojetí existence

    OpenAIRE

    Janatová, Kristýna

    2016-01-01

    The topic of the bachelor thesis is "Kierkegaard's conception of existence". There are both the life of the Danish philosopher Søren Kierkegaard and his philosophy discussed. The issue of human existence is analysed with its main three stages which are focused on aesthetics, ethics and religion. These stages of existence are at first described and afterwards compared with each other. The aesthetic represents the first stage of life and the religious stage is considered to be the highest aim o...

  8. Model-based equipment diagnosis

    Science.gov (United States)

    Collins, David J.; Strojwas, Andrzej J.; Mozumder, P. K.

    1994-09-01

    A versatile methodology is described in which equipment models have been incorporated into a single process diagnostic system for the PECVD of silicon nitride. The diagnosis system has been developed and tested with data collected using an Applied Materials Precision 5000 single wafer reactor. The parametric equipment diagnosis system provides the basis for optimal control of multiple process responses by the classification of potential sources of equipment faults without the assistance of in-situ sensor data. The basis for the diagnosis system is the use of tuned empirical equipment models which have been developed using a physically-based experimental design. Nine individual site-specific models were used to provide an effective method of modeling the spatially-dependent process variations across the wafer with better sensitivity than mean-based models. The diagnostic system has been tested using data that was produced by adjusting the actual equipment controls to artificially simulate a variety of possible subtle equipment drifts and shifts. Statistical algorithms have been implemented which detect equipment drift, shift and variance stability faults using the difference between the predicted process responses to the off-line measured process responses. Fault classification algorithms have been developed to classify the most likely causes for the process drifts and shifts using a pattern recognition system based upon flexible discriminant analysis.

  9. An interdepartmental, standardized equipment pool.

    Science.gov (United States)

    Fahlstrøm, Elisabeth; Grimnes, Sverre; Johannejen, Nann Helene

    2006-03-01

    To solve problems concerning patient equipment with emphasis on patient care, nursing quality and better nursing management. A monitoring system, designed to follow the patient around in the hospital was discovered. Based on this concept a special, standardized pool system managed by the Clinical Engineering Department was developed. An all-department standardization of monitors and pumps was tried. With pumps it was a success. With monitors, two of 21 departments preferred non-standardized equipment. The equipment pool has successfully been run for 5 years. An evaluation showed that nursing care is better and that only 2% of those asked disapproved of the system. The pool eliminated problems like lack of equipment when needed, the wrong type of equipment found, lack of fitting disposables, the items that could be found being out of order or too dirty to be used. Nurses no longer waste time searching for equipment ready for use. Bedside equipment in working order can always be found in one of the storerooms. As a result, patient safety was greatly enhanced. We also show that this is economically a good system.

  10. Towards Truly Quiet MRI: animal MRI magnetic field gradients as a test platform for acoustic noise reduction

    Science.gov (United States)

    Edelstein, William; El-Sharkawy, Abdel-Monem

    2013-03-01

    Clinical MRI acoustic noise, often substantially exceeding 100 dB, causes patient anxiety and discomfort and interferes with functional MRI (fMRI) and interventional MRI. MRI acoustic noise reduction is a long-standing and difficult technical challenge. The noise is basically caused by large Lorentz forces on gradient windings--surrounding the patient bore--situated in strong magnetic fields (1.5 T, 3 T or higher). Pulsed currents of 300 A or more are switched through the gradient windings in sub-milliseconds. Experimenting with hardware noise reduction on clinical scanners is difficult and expensive because of the large scale and weight of clinical scanner components (gradient windings ~ 1000 kg) that require special handling equipment in large engineering test facilities. Our approach is to produce a Truly Quiet (noise reduction measures that can be implemented in clinical scanners. We have so far decreased noise in an animal scale imager from 108 dB to 71 dB, a 37 dB reduction. Our noise reduction measures include: a gradient container that can be evacuated; inflatable antivibration mounts to prevent transmission of vibrations from gradient winding to gradient container; vibration damping of wires going from gradient to the outside world via the gradient container; and a copper passive shield to prevent the generation of eddy currents in the metal cryostat inner bore, which in turn can vibrate and produce noise.

  11. 40 CFR 63.1159 - Operational and equipment standards for existing, new, or reconstructed sources.

    Science.gov (United States)

    2010-07-01

    ... Pollutants for Steel Pickling-HCl Process Facilities and Hydrochloric Acid Regeneration Plants § 63.1159... regeneration plant. The owner or operator of an affected plant must operate the affected plant at all times...

  12. Expanding Internet Sales of Kendo Equipment and the Response of Existing Retail Stores

    National Research Council Canada - National Science Library

    和田, 崇

    2016-01-01

    剣道用具の生産・流通は,伝統的職人による家内制手工業が中心の1950年代以前,汎用品需要の拡大に伴って工場制の生産が拡大した1960-80年代,製造拠点の海外移転と製販統合の進展とともに,ネット通販が行われるようになった1990...

  13. High Spatiotemporal Resolution Prostate MRI

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-15-1-0341 TITLE: High Spatiotemporal Resolution Prostate MRI PRINCIPAL INVESTIGATOR: Stephen J. Riederer, Ph.D...Resolution Prostate MRI 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-15-1-0341 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Stephen J. Riederer E-Mail...overall purpose of this project is to develop improved means using MRI for detecting prostate cancer with the potential for differentiating disease

  14. Consideration of higher seismic loads at existing plants

    Energy Technology Data Exchange (ETDEWEB)

    Liebig, J.; Pellissetti, M.

    2015-07-01

    Because of advancement of methods in probabilistic seismic hazard analysis, plenty of existing plants face higher seismic loads as an obligation from the national authorities. In case of such obligations safety related structures and equipment have to be reevaluated or requalified for the increased seismic loads. The paper provides solutions for different kinds of structures and equipment inside the plant, avoiding cost intensive hardware exchange. Due to higher seismic loads different kinds of structures and equipment inside a plant have to be reevaluated. For civil structures, primary components, mechanical components, distribution lines and electrical and I&C equipment different innovative concepts will be applied to keep structures and equipment qualified for the higher seismic loads. Detailed analysis, including the modeling of non-linear phenomena, or minor structural upgrades are cost competitive, compared to cost intensive hardware exchanges. Several case studies regarding the re-evaluation and requalification of structures and equipment due to higher seismic loads are presented. It is shown how the creation of coupled finite element models and the consistent propagation of acceleration time histories through the soil, building and primary circuit lead to a significant load reduction Electrical and I&C equipment is reinforced by smart upgrades which increase the natural equipment frequencies. Therefore for all devices inside the cabinets the local acceleration will not increase and the seismic qualification will be maintained. The case studies cover both classical deterministic and probabilistic re-evaluations (fragility analysis). Furthermore, the substantial benefits of non-linear limit load evaluation, such as push-over analysis of buildings and limit load analysis of fuel assemblies, are demonstrated. (Author)

  15. MRI assessment program. Consensus statement on clinical efficacy of MRI

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-05-01

    This consensus statement is largely based on the experience gained at the MRI units at the four hospitals which have operated scanners in the MRI program. It reflects the considered opinion of the radiologists responsible for the MRI services at those hospitals. Account has also been taken of relevant overseas data. This collection of opinion relates particularly to comparison with other imaging modalities. The specific comments will require further consideration as technical developments with MRI become available, additional experience is gained with gadolinium contrast material and additional data are obtained on the influence of MRI on patient management. MRI, at present, is used either to improve diagnostic accuracy when other tests are negative or equivocal, when there is strong clinical suspicion of disease, or to improve surgical or other management planning when the diagnosis known. In some situations (eg syringomyelia, congenital spinal disease, posterior fossa/cerebello-pontine angle tumours) it may entirely replace other tests (eg myelography, air contrast, CT) which are substantially less accurate and/or more invasive. In other situations (eg hemispheric brain tumours, lumbar disc protrusions) when other tests, such as CT, can be as accurate, MRI is not usually or initially indicated because it is currently more expensive and of limited availability. However, balanced against this is the fact that it does not expose the patient to potentially harmful ionising radiation. It is also stressed that MRI images depend on complex, widely variable and, as yet, incompletely understood parameters. There is concern that this may result in false positive diagnoses, especially where MRI is used alone as a screening test, or used as the initial test. For several reasons (availability, cost, medical and diagnostic efficacy), the specific comments on indications for MRI presented are based upon the assumption that MRI is a tertiary and complementary imaging examination

  16. EMR Measurements on NDA Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Macdonell, Alexander Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meierbachtol, Krista Cruse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Evans, James Walter Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mayo, Douglas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

  17. EAS Equipment Authorization Grantee Registrations

    Data.gov (United States)

    Federal Communications Commission — EAS (Equipment Authorization System). Radio Frequency (RF) devices are required to be properly authorized under 47 CFR Part 2 prior to being marketed or imported...

  18. ENERGY STAR Certified Imaging Equipment

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Imaging Equipment that are effective as of...

  19. 21 CFR 225.30 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Equipment. 225.30 Section 225.30 Food and Drugs... Equipment § 225.30 Equipment. (a) Equipment which is designed to perform its intended function and is properly installed and used is essential to the manufacture of medicated feeds. Such equipment permits...

  20. 46 CFR 154.1430 - Equipment locker.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Equipment locker. 154.1430 Section 154.1430 Shipping... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Safety Equipment § 154.1430 Equipment locker. One of each item of equipment under §§ 154.1400 and 154.1420 must be...

  1. 7 CFR 550.38 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Equipment. 550.38 Section 550.38 Agriculture... Equipment/property Standards § 550.38 Equipment. (a) The Cooperator shall not use equipment acquired with... the Federal Government retains an interest in the equipment. (b) The Cooperator shall use the...

  2. 21 CFR 226.30 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Equipment. 226.30 Section 226.30 Food and Drugs... Facilities and Equipment § 226.30 Equipment. Equipment used for the manufacture, processing, packaging, bulk... facilitate maintenance and operation for its intended purpose. The equipment shall: (a) Be so constructed...

  3. 40 CFR 63.1003 - Equipment identification.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Equipment identification. 63.1003...) National Emission Standards for Equipment Leaks-Control Level 1 § 63.1003 Equipment identification. (a) General equipment identification. Equipment subject to this subpart shall be identified. Identification of...

  4. Performance Comparison of 1.5 T Endorectal Coil MRI with Non-Endorectal Coil 3.0 T MRI in Patients with Prostate Cancer

    Science.gov (United States)

    Shah, Zarine K.; Elias, Saba N.; Abaza, Ronney; Zynger, Debra L.; DeRenne, Lawrence A.; Knopp, Michael V.; Guo, Beibei; Schurr, Ryan; Heymsfield, Steven B.; Jia, Guang

    2015-01-01

    Rationale and Objectives To compare prostate morphology, image quality, and diagnostic performance of 1.5 T endorectal coil MRI and 3.0 T non-endorectal coil MRI in patients with prostate cancer. Materials and Methods MR images obtained of 83 patients with prostate cancer using 1.5 T MRI systems with an endorectal coil were compared to images collected from 83 patients with a 3.0 T MRI system. Prostate diameters were measured and image quality was evaluated by one ABR-certified radiologist (Reader 1) and one ABR-certified diagnostic medical physicist (Reader 2). The likelihood of the peripheral zone cancer presence in each sextant and local extent were rated and compared with histopathologic findings. Results Prostate anterior-posterior diameter measured by both readers was significantly shorter with 1.5 T endorectal MRI than with 3.0 T MRI. The overall image quality score difference was significant only for Reader 1. Both readers found that the two MRI systems provided similar diagnostic accuracy in cancer localization, extraprostatic extension, and seminal vesicle involvement. Conclusion Non-endorectal coil 3.0 T MRI provides prostate images that are natural in shape and that have comparable image quality to those obtained at 1.5 T with an endorectal coil, but not superior diagnostic performance. These findings suggest an opportunity exists for improving technical aspects of 3.0 T prostate MRI. PMID:25579637

  5. Extreme learning machine-based classification of ADHD using brain structural MRI data

    National Research Council Canada - National Science Library

    Peng, Xiaolong; Lin, Pan; Zhang, Tongsheng; Wang, Jue

    2013-01-01

    .... ADHD has been associated with multiple cortical features from structural MRI data. However, most existing learning algorithms for ADHD identification contain obvious defects, such as time-consuming training, parameters selection, etc...

  6. Cerebral lesions can impair fMRI-based language lateralization.

    Science.gov (United States)

    Wellmer, Jörg; Weber, Bernd; Urbach, Horst; Reul, Jürgen; Fernandez, Guillen; Elger, Christian E

    2009-10-01

    Several small patient studies and case reports raise concerns that the reliability of functional magnetic resonance imaging (fMRI) may be impaired in the vicinity of cerebral lesions. This could affect the clinical validity of fMRI for presurgical language lateralization. The current study sets out to identify if a systematic effect of lesion type and localization on fMRI exists. We classify lesions typically occurring in epilepsy patients according to (1) their potential to disturb blood oxygenation level dependent (BOLD)-effect generation or detection or to disturb spatial brain normalization, and (2) the proximity of lesions to protocol-specific volumes of interest (VOIs). The effect of lesions is evaluated through the examination of 238 epilepsy patients and a subgroup of 37 patients with suspected unilateral left-language dominance according to the Wada test. Patients with fMRI-critical lesions such as cavernomas, gliomas, and mass defects close to VOIs, or with severe atrophy, show lower lateralization indices (LIs) and more often discordant language lateralization with the Wada test than do patients without such lesions. This study points seriously toward fMRI-language lateralization being sensitive to cerebral lesions. Some lesion types and locations are more critical than others. Our results question the noncritical application of fMRI in patients with cerebral lesions.

  7. Evolution of MRI abnormalities in paediatric acute disseminated encephalomyelitis.

    Science.gov (United States)

    Wong, Yu Yi M; van Pelt, E Daniëlle; Ketelslegers, Immy A; Catsman-Berrevoets, Coriene E; Hintzen, Rogier Q; Neuteboom, Rinze F

    2017-03-01

    Acute disseminating encephalomyelitis (ADEM) is an inflammatory demyelinating disease affecting the central nervous system and mainly occurs in young children. Children who initially presented with ADEM can be diagnosed with multiple sclerosis (MS) in case new non-encephalopathic clinical symptoms occur with new lesions on MRI at least three months after onset of ADEM. We aim to study the timing of MRI abnormalities related to the evolution of clinical symptoms in our Dutch paediatric ADEM cohort. The Dutch database for acquired demyelinating syndromes (ADS) was screened for children under age eighteen fulfilling the international consensus diagnostic criteria for ADEM. Children were eligible when the first MRI was performed within the first three months after onset of clinical symptoms and at least one brain follow-up MRI was available for evaluation. Forty-two children with ADEM were included (median age four years two months). All available MRIs and medical records were assessed and categorised as 'improved', 'deteriorated' and 'unchanged'. We found that during clinical recovery, new lesions and enlargement of existing MRI lesions occurred in the first three months in about 50% of the performed MRIs. In contrast, this was rarely seen more than three months after first onset of ADEM. We recommend to perform a brain MRI as a reference scan three months after onset. Follow-up imaging should be compared with this scan in order to prevent an incorrect diagnosis of MS after ADEM. Copyright © 2016 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

  8. Ovarian cysts on prenatal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Ursula [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Nemec, Stefan F., E-mail: stefan.nemec@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Medical Genetics Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, PACT Suite 400, Los Angeles, CA 90048 (United States); Bettelheim, Dieter [Department of Obstetrics and Gynaecology, Division of Prenatal Diagnosis and Therapy, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University Vienna, Waehringerstrasse 13, A-1090 Vienna (Austria); Horcher, Ernst [Department of Pediatric Surgery, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Schoepf, Veronika [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Graham, John M.; Rimoin, David L. [Medical Genetics Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, PACT Suite 400, Los Angeles, CA 90048 (United States); Weber, Michael; Prayer, Daniela [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2012-08-15

    Objective: Ovarian cysts are the most frequently encountered intra-abdominal masses in females in utero. They may, at times, require perinatal intervention. Using magnetic resonance imaging (MRI) as an adjunct to ultrasonography (US) in prenatal diagnosis, we sought to demonstrate the ability to visualize ovarian cysts on prenatal MRI. Materials and methods: This retrospective study included 17 fetal MRI scans from 16 female fetuses (23-37 gestational weeks) with an MRI diagnosis of ovarian cysts after suspicious US findings. A multiplanar MRI protocol was applied to image and to characterize the cysts. The US and MRI findings were compared, and the prenatal findings were compared with postnatal imaging findings or histopathology. Results: Simple ovarian cysts were found in 10/16 cases and complex cysts in 7/16 cases, including one case with both. In 11/16 (69%) cases, US and MRI diagnoses were in agreement, and, in 5/16 (31%) cases, MRI specified or expanded the US diagnosis. In 6/16 cases, postnatal US showed that the cysts spontaneously resolved or decreased in size, and in 1/16 cases, postnatal imaging confirmed a hemorrhagic cyst. In 4/16 cases, the prenatal diagnoses were confirmed by surgery/histopathology, and for the rest, postnatal correlation was not available. Conclusion: Our results illustrate the MRI visualization of ovarian cysts in utero. In most cases, MRI will confirm the US diagnosis. In certain cases, MRI may provide further diagnostic information, additional to US, which is the standard technique for diagnosis, monitoring, and treatment planning.

  9. Dynamic MRI for evaluation of lumbar canal stenosis. Observation of hemodynamics in cauda equina

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yoshihiko; Kobayashi, Shigeru; Yoshizawa, Hidezo; Nakai, Sadaaki; Shizu, Naoyuki [Fujita Health Univ., Toyoake, Aichi (Japan). School of Medicine; Hayakawa, Katsuhiko; Nakane, Takashi

    1997-04-01

    Hemodynamics in cauda equina was studied in 12 patients with dynamic MRI to see the pathology of intermittent claudication with lumbar canal stenosis. Ten control subjects had neither limp nor apparent stenosis as observed by roentgenography and MRI. Before and after dynamic MRI, ordinary MRI was performed by spin echo method with Hitachi MRP 2000 (0.3 T) with conditions of: T1 weight TR/TE=570/25 msec; T2 weight TR/TE 4250/117 msec; slice thickness 7 mm; matrix 256 x 256. Dynamic MRI was performed by gradient echo method 0.5, 1, 1.5, 2, 4, 6, 8 and 10 min after bolus intravenous injection of gadolinium diethylene triquamine penta-acetic acid with conditions of: flip angle 70deg; TR=60 msec; slice 7 mm; matrix 256 x 224. Dynamic MRI was evaluated by the image analyzer equipped in the MRI apparatus on the ROI to compute the signal intensity (SI) ratio (SI after contrasting-SI before contrasting/SI before contrasting) to give the time intensity curve. Followings were observed and discussed: significance of dynamic MRI in the subject disease, cross areas of dura tube in lumbar canal stenosis, hemodynamics in cauda equina, mechanisms of nerve root edema development and its significance, and mechanisms of appearance of intermittent claudication. (K.H.)

  10. EEG-assisted retrospective motion correction for fMRI: E-REMCOR

    CERN Document Server

    Zotev, Vadim; Phillips, Raquel; Bodurka, Jerzy

    2012-01-01

    We propose a method for retrospective motion correction of fMRI data in simultaneous EEG-fMRI that employs the EEG array as a sensitive motion detector. EEG motion artifacts are used to generate motion regressors describing rotational head movements with millisecond temporal resolution. These regressors are employed for slice-specific motion correction of unprocessed fMRI data. The method does not require any specialized equipment beyond the standard EEG-fMRI instrumentation. Its performance is demonstrated by correction of fMRI data from four patients with major depressive disorder, who exhibited random head movements by 1-3 mm during a resting EEG-fMRI run. The fMRI datasets, corrected using eight EEG-based motion regressors, show significant improvements in temporal SNR (tSNR) of fMRI time series, particularly in the frontal brain regions and near the surface of the brain. The tSNR improvements are as high as 50% for large brain areas in single-subject analysis and as high as 25% when the results are avera...

  11. Medical equipment donations in Haiti: flaws in the donation process.

    Science.gov (United States)

    Dzwonczyk, Roger; Riha, Chris

    2012-04-01

    The magnitude 7.0 earthquake that struck Haiti on 12 January 2010 devastated the capital city of Port-au-Prince and the surrounding area. The area's hospitals suffered major structural damage and material losses. Project HOPE sought to rebuild the medical equipment and clinical engineering capacity of the country. A team of clinical engineers from the United States of America and Haiti conducted an inventory and assessment of medical equipment at seven public hospitals affected by the earthquake. The team found that only 28% of the equipment was working properly and in use for patient care; another 28% was working, but lay idle for technical reasons; 30% was not working, but repairable; and 14% was beyond repair. The proportion of equipment in each condition category was similar regardless of whether the equipment was present prior to the earthquake or was donated afterwards. This assessment points out the flaws that existed in the medical equipment donation process and reemphasizes the importance of the factors, as delineated by the World Health Organization more than a decade ago, that constitute a complete medical equipment donation.

  12. Comprehensive framework for preventive maintenance priority of medical equipment.

    Science.gov (United States)

    Saleh, Neven; Balestra, Gabriella

    2015-08-01

    Throughout the medical equipment life cycle, preventive maintenance is considered one of the most important stages that should be managed properly. However, the need for better management and control by giving a reasonable prioritization for preventive maintenance becomes essential. The purpose of this study is to develop a comprehensive framework for preventive maintenance priority of medical equipment using Quality Function Deployment (QFD) and Fuzzy Logic (FL). The quality function deployment is proposed in order to identify the most important criteria that could impact preventive maintenance priority decision; meanwhile the role of the fuzzy logic is to generate a priority index of the list of equipment considering those criteria. The model validation was carried out on 140 pieces of medical equipment belonging to two hospitals. In application, we propose to classify the priority index into five classes. The results indicate that the strong correlation existence between risk-based criteria and preventive maintenance priority decision.

  13. MRI in intraspinal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, R.K. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Gupta, S. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Kumar, S. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Kohli, A. (Dept. of Neurology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Misra, U.K. (Dept. of Neurology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Gujral, R.B. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India))

    1994-01-01

    We studied 20 patients with intraspinal tuberculosis (TB), to characterise the MRI features of tuberculous meningitis and myelitis. MRI leptomeningitis and intramedullary involvement in 11 patients, intramedullary lesions alone in 5, leptomeningitis alone in 2, and isolated extradural disease in 2. TB leptomeningitis was characterised by loculation of the cerebrospinal fluid (CSF), nerve root thickening and clumping (seen only in the lumbar region) or complete obliteration of the subarachnoid space on unenhanced images. Gd-DTPA-enhanced images proved useful in 6 cases, revealing linear enhancement of the surface of the spinal cord and nerve roots or plaque-like enhancement of the dura-arachnoid mater complex. Intramedullary lesions included tuberculomas (8), cord oedema (5) and cavitation (3). In seven cases of intramedullary tuberculoma multiple lesions with skip areas were seen, without significant cord swelling. One patient had an isolated lesion in the conus medullaris. The lesions were iso- or hypointense on T1-weighted images, iso-, hypo- or hyperintense on T2-weighted images and showed rim or nodular enhancement with contrast medium. (orig.)

  14. Musculoskeletal MRI: dedicated systems

    Energy Technology Data Exchange (ETDEWEB)

    Masciocchi, C.; Barile, A. [Dept. of Radiology, University of L' Aquila (Italy); Satragno, L. [MRI Research Div., Esaote SpA, Genoa (Italy)

    2000-02-01

    The ''dedicated'' MRI units have characteristics of high diagnostic accuracy and lower installation and management costs as compared with whole-body systems. The dedicated MRI units are easy to install. The low weight allows their installation also under unfavorable circumstances. In a dedicated system cost-effectiveness and ease of installation must be accompanied by the capability of providing high-quality images. In our experience, the high number of examinations performed, the most part of which provided with the surgical controls, allowed an accurate evaluation of the diagnostic potentialities of the dedicated magnet. We were not able to perform the examinations in only 3 % of cases due to the physical shape of the patient and the clinical condition of the patient which may hinder the correct positioning of the limb. The overlapping of the diagnostic accuracy of the E-scan and Artoscan units in the study of the lower limbs, compared with whole-body units and surgery, prompted us to exploit the potentialities of the E-Scan in the study of the shoulder. We had a good correlation between E-Scan, whole-body units, and surgical findings, which confirmed the high diagnostic accuracy of the dedicated system. In conclusion, in our experience carried out in the musculoskeletal system, the dedicated magnets showed promising results. Their diagnostic reliability and utility was comparable to that obtained from conventional units operating at higher magnetic fields. (orig.)

  15. Tailgut cysts: MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Aflalo-Hazan, V.; Rousset, P.; Lewin, M.; Azizi, L. [Hopital Saint Antoine, Department of Radiology, PARIS Cedex 12 (France); Mourra, N. [Hopital Saint Antoine, Department of Pathology, PARIS Cedex 12 (France); Hoeffel, C. [Hopital Robert Debre, Department of Radiology, Reims Cedex (France)

    2008-11-15

    Magnetic resonance imaging (MRI) features of 11 surgically resected pelvic tailgut cysts were analyzed with reference to histopathologic and clinical data. Homogeneity, size, location, signal intensity, appearance and presence of septa and/or nodules and/or peripheral rim and involvement of surrounding structures were studied. Histological examination demonstrated 11 tailgut cysts (TGC), including one infected TGC and one TGC with a component of adenocarcinoma. Lesions (3-8 cm in diameter) were exclusively or partly retrorectal in all cases but one, with an extension down the anal canal in five cases. Lesions were multicystic in all patients but one. On T1-weighted MR images, all cystic lesions contained at least one hyperintense cyst. The peripheral rim of the cystic lesion was regular and non or moderately enhancing in all cases but the two complicated TGC. Nodular peripheral rim and irregular septa were seen in the degenerated TGC. Marked enhancement of the peripheral structures was noted in the two complicated TGC. Pelvic MRI is a valuable tool in the preoperative evaluation of TGC. (orig.)

  16. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F. [Charite University Medicine Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Bretschneider, T. [Magdeburg Univ. (Germany). Dept. of Radiology and Nuclear Medicine; Hartwig, T.; Disch, A.C. [Charite University Medicine Berlin (Germany). Center for Musculoskeletal Surgery

    2014-06-15

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  18. Postmortem MRI of bladder agenesis

    Energy Technology Data Exchange (ETDEWEB)

    Barber, Brendan R. [St George' s Hospital, Radiology Department, London (United Kingdom); Weber, Martin A. [Great Ormond Street Hospital for Children, Department of Histopathology, London (United Kingdom); Bockenhauer, Detlef [Great Ormond Street Hospital for Children, Department of Nephrology, London (United Kingdom); Hiorns, Melanie P.; McHugh, Kieran [Great Ormond Street Hospital for Children, Radiology Department, London (United Kingdom)

    2011-01-15

    We report a 35-week preterm neonate with bladder agenesis and bilateral dysplastic kidneys. A suprapubic catheter was inadvertently inserted into one of the larger inferior cysts of the left dysplastic kidney. A postmortem MRI scan was performed with the findings being confirmed on autopsy. We are unaware of another postmortem MRI study demonstrating bladder agenesis. (orig.)

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... can help physicians evaluate the structures of the brain and can also provide functional information (fMRI) in ...

  20. Getting an MRI (For Kids)

    Medline Plus

    Full Text Available ... Quizzes Kids' Dictionary of Medical Words En Español What Other Kids Are Reading About Recipes for Kids With Diabetes Can ... Do I Help a Kid Who's Bullied? Getting an MRI (Video) KidsHealth > For Kids > Getting an MRI ( ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... zippers and similar metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In ... scanner. top of page How does the procedure work? Unlike ... (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... other internal body structures. MRI does not use ionizing radiation (x-rays). Detailed MR images allow physicians to evaluate various parts of the ... imaging technique that does not involve exposure to ionizing radiation. MRI can ... cases. MR images of the brain and other cranial structures are ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... absolutely necessary for medical treatment. See the MRI Safety page for more information about pregnancy and MRI. ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... contrast for an MRI. If you have a history of kidney disease or liver transplant, it will be necessary to perform a blood test to determine whether the kidneys are ... between cancer tissue and fluid, known as edema . MRI typically ...

  6. MRI Findings In Dengue Encephalitis

    Directory of Open Access Journals (Sweden)

    Ashraf V.V

    2004-01-01

    Full Text Available Neurological manifestations are rare in dengue fever. Two cases with encephalopathy and systemic features of dengue fever with abnormal CSF and MR imaging are reported. Striking MRI finding was bilateral symmetrical thalamic lesions similar to those reported in Japanese encephalitis. This report highlights that MRI findings can be similar in dengue and Japanese encephalitis.

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  9. Integration of Industrial Equipment and Distributed Control Systems into the Control Infrastructure at CERN

    CERN Document Server

    Lauckner, R J

    1997-01-01

    CERN Accelerators and Services have an existing large investment in control networks, fieldbuses, front-end process computers, workstations, system software and application programs. Increasingly, industrial equipment and complete Distributed Control Systems (DCS) are being installed to rejuvenate old and obsolete systems and new projects for LHC are taking shape. The object of this paper is to report experience of CERNs control engineers on integration of industrial equipment and systems. Several projects are described covering a vast area of applications. The paper presents several interfacing issues such as network connection of industrial equipment, software integration, homogeneous equipment access and alarm retrieval compatible with the existing Accelerators and Services Control System.

  10. 14 CFR 25.1415 - Ditching equipment.

    Science.gov (United States)

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Safety Equipment § 25.1415 Ditching equipment. (a... preservers, there must be an approved flotation means for each occupant. This means must be within easy reach...

  11. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  12. Seismic analyses of equipment in 2736-Z complex. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Ocoma, E.C.

    1995-04-01

    This report documents the structural qualification for the existing equipment when subjected to seismic loading in the Plutonium Storage Complex. It replaces in entirety Revision 0 and reconciles the U.S. Department of Energy (DOE) comments on Revision 0. The Complex consists of 2736-Z Building (plutonium storage vault), 2736-ZA Building (vault ventilation equipment building), and 2736-ZB Building (shipping/receiving, repackaging activities). The existing equipment structurally qualified in this report are the metal storage racks for 7 inch and lard cans in room 2 of Building 2736-Z; the cubicles, can holders and pedestals in rooms 1, 3, and 4 of Building 2736-Z; the ventilation duct including exhaust fans/motors, emergency diesel generator, and HEPA filter housing in Building 2736-ZA; the repackaging glovebox in Building 2736-ZB; and the interface duct between Buildings 2736-Z and 2736-ZA.

  13. Visualizing electromagnetic vacuum by MRI

    CERN Document Server

    Chandrashekar, Chandrika S; Chandrashekar, S; Taylor, Erika A; Taylor, Deanne M

    2016-01-01

    Based upon Maxwell's equations, it has long been established that oscillating electromagnetic (EM) fields incident upon a metal surface decay exponentially inside the conductor, leading to a virtual EM vacuum at sufficient depths. Magnetic resonance imaging (MRI) utilizes radiofrequency (r.f.) EM fields to produce images. Here we present the first visualization of an EM vacuum inside a bulk metal strip by MRI, amongst several novel findings. We uncover unexpected MRI intensity patterns arising from two orthogonal pairs of faces of a metal strip, and derive formulae for their intensity ratios. Further, we furnish chemical shift imaging (CSI) results that discriminate different faces (surfaces) of a metal block according to their distinct nuclear magnetic resonance (NMR) chemical shifts, which holds much promise for monitoring surface chemical reactions noninvasively. Bulk metals are ubiquitous, and MRI is a premier noninvasive diagnostic tool. Combining the two, the emerging field of bulk metal MRI can be expe...

  14. Aeration equipment for small depths

    Directory of Open Access Journals (Sweden)

    Sluše Jan

    2015-01-01

    Full Text Available Deficit of air in water causes complications with cyanobacteria mainly in the summer months. Cyanobacteria is a bacteria that produces poison called cyanotoxin. When the concentration of cyanobacteria increases, the phenomena „algal bloom“ appears, which is very toxic and may kill all the organisms. This article describes new equipment for aeration of water in dams, ponds and reservoirs with small depth. This equipment is mobile and it is able to work without any human factor because its control is provided by a GPS module. The main part of this equipment consists of a floating pump which pumps water from the surface. Another important part of this equipment is an aerator where water and air are blended. Final aeration process runs in the nozzles which provide movement of all this equipment and aeration of the water. Simulations of the flow are solved by multiphase flow with diffusion in open source program called OpenFOAM. Results will be verified by an experiment.

  15. Ultrasound: Can it replace MRI in the evaluation of the rotator cuff tears?

    Directory of Open Access Journals (Sweden)

    Samira Saraya

    2016-03-01

    Conclusion: Ultrasound and MRI are comparable in both sensitivity and specificity. Since US is less expensive and more available, it could be considered as the screening method when rotator cuff integrity is the main question, if well-trained radiologists and high resolution equipments are available.

  16. MRI findings in Hirayama disease

    Directory of Open Access Journals (Sweden)

    Raval Monali

    2010-01-01

    Full Text Available The objective of the study was to study the magnetic resonance imaging (MRI features of Hirayama disease on a 3 Tesla MRI scanner. Nine patients with clinically suspected Hirayama disease were evaluated with neutral position, flexion, contrast-enhanced MRI and fast imaging employing steady-state acquisition (FIESTA sequences. The spectrum of MRI features was evaluated and correlated with the clinical and electromyography findings. MRI findings of localized lower cervical cord atrophy (C5-C7, abnormal curvature, asymmetric cord flattening, loss of attachment of the dorsal dural sac and subjacent laminae in the neutral position, anterior displacement of the dorsal dura on flexion and a prominent epidural space were revealed in all patients on conventional MRI as well as with the dynamic 3D-FIESTA sequence. Intramedullary hyperintensity was seen in four patients on conventional MRI and on the 3D-FIESTA sequence. Flow voids were seen in four patients on conventional MRI sequences and in all patients with the 3D-FIESTA sequence. Contrast enhancement of the epidural component was noted in all the five patients with thoracic extensions. The time taken for conventional and contrast-enhanced MRI was about 30-40 min, while that for the 3D-FIESTA sequence was 6 min. Neutral and flexion position MRI and the 3D-FIESTA sequence compliment each other in displaying the spectrum of findings in Hirayama disease. A flexion study should form an essential part of the screening protocol in patients with suspected Hirayama disease. Newer sequences such as the 3D-FIESTA may help in reducing imaging time and obviating the need for contrast.

  17. Barriers and Factors Affecting Personal Protective Equipment Usage ...

    African Journals Online (AJOL)

    ADMIN

    However compliance to it by HCWs has remained poor even in high-risk clinical situation. The objective of this study was to ... Protective Equipment (PPE) and the barriers that exist in preventing their use. Subjects and Methods ... samples, ward round, wound dressing, drug administration and injection. Those working in.

  18. Existing Steel Railway Bridges Evaluation

    Directory of Open Access Journals (Sweden)

    Vičan Josef

    2016-12-01

    Full Text Available The article describes general principles and basis of evaluation of existing railway bridges based on the concept of load-carrying capacity determination. Compared to the design of a new bridge, the modified reliability level for existing bridges evaluation should be considered due to implementation of the additional data related to bridge condition and behaviour obtained from regular inspections. Based on those data respecting the bridge remaining lifetime, a modification of partial safety factors for actions and materials could be respected in the bridge evaluation process. A great attention is also paid to the specific problems of determination of load-caring capacity of steel railway bridges in service. Recommendation for global analysis and methodology for existing steel bridge superstructure load-carrying capacity determination are described too.

  19. Another donation of computer equipment

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On Thursday 27 February, CERN was pleased to donate computer equipment to a physics institute in the Philippines.   H.E. Leslie J. Baja and Rolf Heuer. Following donations of computer equipment to institutes in Morocco, Ghana, Bulgaria, Serbia and Egypt, CERN is to send 50 servers and 4 network switches to the National Institute of Physics at the University of the Philippines Diliman. CERN’s Director-General Rolf Heuer and the Ambassador of the Philippines to Switzerland and Lichtenstein, H.E. Leslie J. Baja, spoke of their enthusiasm for the project during an official ceremony. The equipment will be used for various high energy physics research programmes in the Philippines and for the University’s development of digital resources for science.

  20. Lack of security of networked medical equipment in radiology.

    Science.gov (United States)

    Moses, Vinu; Korah, Ipeson

    2015-02-01

    OBJECTIVE. There are few articles in the literature describing the security and safety aspects of networked medical equipment in radiology departments. Most radiologists are unaware of the security issues. We review the security of the networked medical equipment of a typical radiology department. MATERIALS AND METHODS. All networked medical equipment in a radiology department was scanned for vulnerabilities with a port scanner and a network vulnerability scanner, and the vulnerabilities were classified using the Common Vulnerability Scoring System. A network sniffer was used to capture and analyze traffic on the radiology network for exposure of confidential patient data. We reviewed the use of antivirus software and firewalls on the networked medical equipment. USB ports and CD and DVD drives in the networked medical equipment were tested to see whether they allowed unauthorized access. Implementation of the virtual private network (VPN) that vendors use to access the radiology network was reviewed. RESULTS. Most of the networked medical equipment in our radiology department used vulnerable software with open ports and services. Of the 144 items scanned, 64 (44%) had at least one critical vulnerability, and 119 (83%) had at least one high-risk vulnerability. Most equipment did not encrypt traffic and allowed capture of confidential patient data. Of the 144 items scanned, two (1%) used antivirus software and three (2%) had a firewall enabled. The USB ports were not secure on 49 of the 58 (84%) items with USB ports, and the CD or DVD drive was not secure on 17 of the 31 (55%) items with a CD or DVD drive. One of three vendors had an insecure implementation of VPN access. CONCLUSION. Radiologists and the medical industry need to urgently review and rectify the security issues in existing networked medical equipment. We hope that the results of our study and this article also raise awareness among radiologists about the security issues of networked medical equipment.

  1. Heavy Equipment Operator: General Equipment Operator. Instructional Materials.

    Science.gov (United States)

    Hendrix, Laborn J.; Sawatzky, Joyce

    Developed through close coordination between contractors, construction workers, and vocational educators, this instructor's manual is designed to help heavy equipment instructors present materials in a systematic format. The instructional materials in the manual are written in terms of student performance, using measurable behavioral objectives.…

  2. Mechanical (turbines and auxiliary equipment)

    CERN Document Server

    Sherry, A; Cruddace, AE

    2013-01-01

    Modern Power Station Practice, Volume 3: Mechanical (Turbines and Auxiliary Equipment) focuses on the development of turbines and auxiliary equipment used in power stations in Great Britain. Topics covered include thermodynamics and steam turbine theory; turbine auxiliary systems such as lubrication systems, feed water heating systems, and the condenser and cooling water plants. Miscellaneous station services, and pipework in power plants are also described. This book is comprised of five chapters and begins with an overview of thermodynamics and steam turbine theory, paying particular attenti

  3. MRI in cerebellar hypoplasia

    Energy Technology Data Exchange (ETDEWEB)

    DeSouza, N. [Guy`s Hospital, London (United Kingdom). Dept. of Magnetic Resonance, Div. of Radiological Sciences; Chaudhuri, R. [Guy`s Hospital, London (United Kingdom). Dept. of Magnetic Resonance, Div. of Radiological Sciences; Bingham, J. [Guy`s Hospital, London (United Kingdom). Dept. of Magnetic Resonance, Div. of Radiological Sciences; Cox, T. [Guy`s Hospital, London (United Kingdom). Dept. of Magnetic Resonance, Div. of Radiological Sciences

    1994-02-01

    Cerebellar hypoplasia may present with a wide variety of neurological and systemic features, ranging from aplasia causing neonatal death to mild hypoplasia in an asymptomatic adult. MRI clearly documents the size of the cerebellum and any associated abnormalities. We describe 7 cases of cerebellar hypoplasia of varying aetiology - 3 inherited, 2 associated with spinal dysraphism, 1 with Joubert`s syndrome and 1 with pontine agenesis, probably as a result of basilar artery infarction in utero. T1- and T2-weighted images were obtained in each case and gadolinium-DTPA was administered in one. Associated features such as a Chiari malformation (2 cases), brain stem hypoplasia (2 cases), Dandy-Walker cyst and pachygyria (3 cases) and spinal dysraphism (2 cases) were clearly identified. Accurate documentation of these appearances assists in genetic counselling. (orig.)

  4. Existence of mesons after deconfinement

    NARCIS (Netherlands)

    F. Brau (Fabian); F. Buisseret

    2007-01-01

    textabstractWe investigate the possibility for a quark-antiquark pair to form a bound state at temperatures higher than the critical one ($T>T_c$), thus after deconfinement. Our main goal is to find analytical criteria constraining the existence of such mesons. Our formalism relies on a Schrödinger

  5. Limitations of existing web services

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Limitations of existing web services. Uploading or downloading large data. Serving too many user from single source. Difficult to provide computer intensive job. Depend on internet and its bandwidth. Security of data in transition. Maintain confidentiality of data ...

  6. Performance of Existing Hydrogen Stations

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Samuel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kurtz, Jennifer M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ainscough, Christopher D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Peters, Michael C [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-01

    In this presentation, the National Renewable Energy Laboratory presented aggregated analysis results on the performance of existing hydrogen stations, including performance, operation, utilization, maintenance, safety, hydrogen quality, and cost. The U.S. Department of Energy funds technology validation work at NREL through its National Fuel Cell Technology Evaluation Center (NFCTEC).

  7. Cranial MRI of small rodents using a clinical MR scanner.

    Science.gov (United States)

    Linn, Jennifer; Schwarz, Friederike; Schichor, Christian; Wiesmann, Martin

    2007-09-01

    Increasing numbers of small animal models are in use in the field of neuroscience research. Magnetic resonance imaging (MRI) provides an excellent method for non-invasive imaging of the brain. Using three-dimensional (3D) MR sequences allows lesion volumetry, e.g. for the quantification of tumor size. Specialized small-bore animal MRI scanners are available for high-resolution MRI of small rodents' brain, but major drawbacks of this dedicated equipment are its high costs and thus its limited availability. Therefore, more and more research groups use clinical MR scanners for imaging small animal models. But to achieve a reasonable spatial resolution at an acceptable signal-to-noise ratio with these scanners, some requirements concerning sequence parameters have to be matched. Thus, the aim of this paper was to present in detail a method how to perform MRI of small rodents brain using a standard clinical 1.5 T scanner and clinically available radio frequency coils to keep material costs low and to circumvent the development of custom-made coils.

  8. MRI-powered biomedical devices.

    Science.gov (United States)

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  9. The precision of DCE-MRI using the tissue homogeneity model with continuous formulation of the perfusion parameters

    Czech Academy of Sciences Publication Activity Database

    Bartoš, Michal; Jiřík, Radovan; Kratochvíla, Jiří; Standara, M.; Starčuk jr., Zenon; Torfinn, T.

    2014-01-01

    Roč. 32, č. 5 (2014), s. 505-513 ISSN 0730-725X R&D Projects: GA ČR GAP102/12/2380; GA MŠk ED0017/01/01; GA MŠk(CZ) LO1212 Institutional support: RVO:67985556 ; RVO:68081731 Keywords : dynamic contrast-enhanced MRI (DCE- MRI ) * perfusion * parameter estimation * bolus arrival time Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 2.090, year: 2014

  10. Preventive Maintenance Handbook. Audiovisual Equipment.

    Science.gov (United States)

    Educational Products Information Exchange Inst., Stony Brook, NY.

    The preventive maintenance system for audiovisual equipment presented in this handbook is designed by specialists so that it can be used by nonspecialists in school sites. The report offers specific advice on saftey factors and also lists major problems that should not be handled by nonspecialists. Other aspects of a preventive maintenance system…

  11. Lifting operations and lifting equipment

    NARCIS (Netherlands)

    Douwes, M.

    2013-01-01

    Lifting operations are inherent to many occupations in the construction industry. They can be performed manually or using lifting equipment. Both manual lifting and mechanical lifting operations can put construction workers at great risk of injury or health symptoms causing sick leave or disability.

  12. Numbering of vertebrae on MRI using a PACS cross-referencing tool.

    Science.gov (United States)

    Paik, Nam Chull; Lim, Chun Soo; Jang, Ho Suk

    2012-09-01

    For the detection and documentation of numeric variations on spine magnetic resonance imaging (MRI), different techniques have previously been introduced. However, these methods require additional special imaging algorithms, software, or devices. We intend to introduce a vertebral numbering method using the existing picture archiving and communication system (PACS) and MRI system. To assess the accuracy of a method for numbering presacral vertebrae based on the cross-referencing of two sagittal MRI series. This study was a retrospective review of 224 consecutive patients who underwent both lumbar MRI with cervicothoracic scan and whole spine radiographic examinations. A radiologist and a neurosurgeon independently counted the number of presacral vertebrae in a cranial-to-caudal approach with cross-referencing of cervicothoracic and lumbar MRI sagittal series on the PACS workstation. Radiographic numbering from the cervical through the thoracic to the lumbar vertebrae, as a reference standard, was completed independently by the two reviewers. An analysis of the inter-observer and intermodality agreements of radiography and MRI was done. In all cases except one, concordant numbering existed between the two modalities of MRI cross-referencing and radiographs combination. Both observers agreed completely, with no inter-observer discordance. The number of vertebrae could be identified consistently by counting caudally from C2 with cross-referencing cervicothoracic and lumbosacral sagittal MRI scans on the PACS workstation.

  13. [Retinotopic organization of the human visual cortex: a 3T fMRI study].

    Science.gov (United States)

    Hoffart, L; Conrath, J; Matonti, F; Galland, F; Wotawa, N; Chavane, F; Castet, E; Ridings, B; Masson, G S

    2007-10-01

    INTRODUCTION. We used high-field (3T) functional magnetic resonance imaging (fMRI) to map the retinotopic organization of human cortical areas. Retinotopic maps were reconstructed using existing mapping techniques. Stimuli were made of a rotating wedge stimulus, which provided angular coordinate maps, and an expanding or contracting ring, which provided eccentricity coordinate maps. Stimuli consisted of a grey background alternating with a flickering checkerboard. A Brucker 3T scanner equipped with a head coil and a custom optical system was used to acquire sets of echoplanar images of 20 occipital coronal slices within a RT of 2.111 ms and an 8 mm3 voxel resolution. Surface models of each subject's occipital lobes were constructed using the Brainvisa software from a sagittal T1-weighted image with a 1 mm3 voxel resolution. The cortical models were then inflated to obtain unfolded surfaces. Statistical analyses of the functional data were made under SPM99, and the response amplitudes were finally assigned to the cortical reconstructed surfaces. We identified boundaries between different early visual areas (V1, V2, V3) using eccentricity and polar angle retinotopic maps and detection of reversals in the representation of the polar angle. Both complete maps and reversals corresponding to the V1/V2 borders were clearly visible with a single recording session. Also, we were able to compare data from subjects across various fMRI acquisitions and found that there was a strong correlation between maps acquired at different sessions for the same subject. We developed a quick (mapping method at 3T, which makes it possible to study the cortical remapping in patients with retinal scotomas.

  14. Respiratory challenge MRI: Practical aspects

    OpenAIRE

    Moreton, Fiona C.; Dani, Krishna A.; Goutcher, Colin; O'Hare, Kevin; Muir, Keith W.

    2016-01-01

    Respiratory challenge MRI is the modification of arterial oxygen (PaO2) and/or carbon dioxide (PaCO2) concentration to induce a change in cerebral function or metabolism which is then measured by MRI. Alterations in arterial gas concentrations can lead to profound changes in cerebral haemodynamics which can be studied using a variety of MRI sequences. Whilst such experiments may provide a wealth of information, conducting them can be complex and challenging. In this paper we review the ration...

  15. Compressed sensing MRI with multichannel data using multicore processors.

    Science.gov (United States)

    Chang, Ching-Hua; Ji, Jim

    2010-10-01

    Compressed sensing (CS) is a promising method to speed up MRI. Because most clinical MRI scanners are equipped with multichannel receive systems, integrating CS with multichannel systems may not only shorten the scan time but also provide improved image quality. However, significant computation time is required to perform CS reconstruction, whose complexity is scaled by the number of channels. In this article, we propose a reconstruction procedure that uses ubiquitously available multicore central processing unit to accelerate CS reconstruction from multiple channel data. The experimental results show that the reconstruction efficiency benefits significantly from parallelizing the CS reconstructions and pipelining multichannel data into multicore processors. In our experiments, an additional speedup factor of 1.6-2.0 was achieved using the proposed method on a quad-core central processing unit. The proposed method provides a straightforward way to accelerate CS reconstruction with multichannel data for parallel computation.

  16. Hyperbaric intensive care technology and equipment.

    Science.gov (United States)

    Millar, Ian L

    2015-03-01

    In an emergency, life support can be provided during recompression or hyperbaric oxygen therapy using very basic equipment, provided the equipment is hyperbaric-compatible and the clinicians have appropriate experience. For hyperbaric critical care to be provided safely on a routine basis, however, a great deal of preparation and specific equipment is needed, and relatively few facilities have optimal capabilities at present. The type, size and location of the chamber are very influential factors. Although monoplace chamber critical care is possible, it involves special adaptations and inherent limitations that make it inappropriate for all but specifically experienced teams. A large, purpose-designed chamber co-located with an intensive care unit is ideal. Keeping the critically ill patient on their normal bed significantly improves quality of care where this is possible. The latest hyperbaric ventilators have resolved many of the issues normally associated with hyperbaric ventilation, but at significant cost. Multi-parameter monitoring is relatively simple with advanced portable monitors, or preferably installed units that are of the same type as used elsewhere in the hospital. Whilst end-tidal CO₂ readings are changed by pressure and require interpretation, most other parameters display normally. All normal infusions can be continued, with several examples of syringe drivers and infusion pumps shown to function essentially normally at pressure. Techniques exist for continuous suction drainage and most other aspects of standard critical care. At present, the most complex life support technologies such as haemofiltration, cardiac assist devices and extra-corporeal membrane oxygenation remain incompatible with the hyperbaric environment.

  17. Human Rights Being and Existence

    Directory of Open Access Journals (Sweden)

    Xabier Etexeberria

    2013-05-01

    Full Text Available The ontological perspective in the approach to human rights is subject to different traps,against which measures must be taken. But it also faces us to the challenge of precisely specifying what they are and how are they to be based. In this paper we try to face this challenge, paying attention to avoid the traps above mentioned. The first part of it is focused on being-existence of human rights,trying to specify critically their «places»: social reality, laws and, in a founding sense, human dignity.The second part takes the category being-essence as reference, asking about the kind of being of humanrights in their different types. This «kind» will show itself densely mediated by cultural diversity andtemporality-historicity. What is really pretended with this reflection is to contribute to the cause of thesocial existence of human rights.

  18. The EXIST Mission Concept Study

    Science.gov (United States)

    Fishman, Gerald J.; Grindlay, J.; Hong, J.

    2008-01-01

    EXIST is a mission designed to find and study black holes (BHs) over a wide range of environments and masses, including: 1) BHs accreting from binary companions or dense molecular clouds throughout our Galaxy and the Local Group, 2) supermassive black holes (SMBHs) lying dormant in galaxies that reveal their existence by disrupting passing stars, and 3) SMBHs that are hidden from our view at lower energies due to obscuration by the gas that they accrete. 4) the birth of stellar mass BHs which is accompanied by long cosmic gamma-ray bursts (GRBs) which are seen several times a day and may be associated with the earliest stars to form in the Universe. EXIST will provide an order of magnitude increase in sensitivity and angular resolution as well as greater spectral resolution and bandwidth compared with earlier hard X-ray survey telescopes. With an onboard optical-infra red (IR) telescope, EXIST will measure the spectra and redshifts of GRBs and their utility as cosmological probes of the highest z universe and epoch of reionization. The mission would retain its primary goal of being the Black Hole Finder Probe in the Beyond Einstein Program. However, the new design for EXIST proposed to be studied here represents a significant advance from its previous incarnation as presented to BEPAC. The mission is now less than half the total mass, would be launched on the smallest EELV available (Atlas V-401) for a Medium Class mission, and most importantly includes a two-telescope complement that is ideally suited for the study of both obscured and very distant BHs. EXIST retains its very wide field hard X-ray imaging High Energy Telescope (HET) as the primary instrument, now with improved angular and spectral resolution, and in a more compact payload that allows occasional rapid slews for immediate optical/IR imaging and spectra of GRBs and AGN as well as enhanced hard X-ray spectra and timing with pointed observations. The mission would conduct a 2 year full sky survey in

  19. Custom fit 3D-printed brain holders for comparison of histology with MRI in marmosets.

    Science.gov (United States)

    Guy, Joseph R; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S

    2016-01-15

    MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. Published by Elsevier B.V.

  20. 46 CFR 108.701 - Sounding equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Sounding equipment. 108.701 Section 108.701 Shipping... EQUIPMENT Miscellaneous Equipment § 108.701 Sounding equipment. Each self-propelled unit must have a mechanical or electronic sounding apparatus. ...

  1. 40 CFR 160.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Equipment design. 160.61 Section 160... LABORATORY PRACTICE STANDARDS Equipment § 160.61 Equipment design. Equipment used in the generation... appropriate design and adequate capacity to function according to the protocol and shall be suitably located...

  2. 40 CFR 792.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Equipment design. 792.61 Section 792.61...) GOOD LABORATORY PRACTICE STANDARDS Equipment § 792.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  3. 21 CFR 58.61 - Equipment design.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Equipment design. 58.61 Section 58.61 Food and... PRACTICE FOR NONCLINICAL LABORATORY STUDIES Equipment § 58.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  4. 32 CFR 32.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Equipment. 32.34 Section 32.34 National Defense... ORGANIZATIONS Post-Award Requirements Property Standards § 32.34 Equipment. (a) Title to equipment acquired by a... recipient shall not use equipment acquired with Federal funds to provide services to non-Federal outside...

  5. 10 CFR 600.134 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Equipment. 600.134 Section 600.134 Energy DEPARTMENT OF... Nonprofit Organizations Post-Award Requirements § 600.134 Equipment. (a) Title to equipment acquired by a... recipient shall not use equipment acquired with Federal funds to provide services to non-Federal outside...

  6. 45 CFR 2543.34 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Equipment. 2543.34 Section 2543.34 Public Welfare... Requirements Property Standards § 2543.34 Equipment. (a) Title to equipment acquired by a recipient with... not use equipment acquired with Federal funds to provide services to non-Federal outside organizations...

  7. 7 CFR 3019.34 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Equipment. 3019.34 Section 3019.34 Agriculture....34 Equipment. (a) Title to equipment acquired by a recipient with Federal funds shall vest in the recipient, subject to conditions of this section. (b) The recipient shall not use equipment acquired with...

  8. 20 CFR 435.34 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Equipment. 435.34 Section 435.34 Employees...-Award Requirements Property Standards § 435.34 Equipment. (a) Title to equipment acquired by a recipient... may not use equipment acquired with Federal funds to provide services to non-Federal outside...

  9. 28 CFR 70.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Equipment. 70.34 Section 70.34 Judicial... Post-Award Requirements Property Standards § 70.34 Equipment. (a) Title to equipment acquired by a... recipient must not use equipment acquired with Federal funds to provide services to non-Federal outside...

  10. 49 CFR 19.34 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Equipment. 19.34 Section 19.34 Transportation... Requirements Property Standards § 19.34 Equipment. (a) Title to equipment acquired by a recipient with Federal... use equipment acquired with Federal funds to provide services to non-Federal outside organizations for...

  11. 15 CFR 14.34 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Equipment. 14.34 Section 14.34... ORGANIZATIONS Post-Award Requirements Property Standards § 14.34 Equipment. (a) Title to equipment acquired by a... recipient shall not use equipment acquired with Federal funds to provide services to non-Federal outside...

  12. 21 CFR 225.130 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Equipment. 225.130 Section 225.130 Food and Drugs... CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS Facilities and Equipment § 225.130 Equipment. Equipment shall be capable of producing a medicated feed of intended potency and purity, and shall be...

  13. 46 CFR 153.484 - Prewash equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Prewash equipment. 153.484 Section 153.484 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Design and Equipment for Pollution Control § 153.484 Prewash equipment. Unless the ship operator shows that the prewash...

  14. 34 CFR 74.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Equipment. 74.34 Section 74.34 Education Office of the... Equipment. (a) Title to equipment acquired by a recipient with Federal funds shall vest in the recipient, subject to conditions of this section. (b) The recipient may not use equipment acquired with Federal funds...

  15. 33 CFR 142.48 - Eyewash equipment.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Eyewash equipment. 142.48 Section... CONTINENTAL SHELF ACTIVITIES WORKPLACE SAFETY AND HEALTH Personal Protective Equipment § 142.48 Eyewash equipment. Portable or fixed eyewash equipment providing emergency relief must be immediately available near...

  16. 29 CFR 95.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Equipment. 95.34 Section 95.34 Labor Office of the Secretary... Equipment. (a) Title to equipment acquired by a recipient with Federal funds shall vest in the recipient, subject to conditions of this section. (b) The recipient shall not use equipment acquired with Federal...

  17. 18 CFR 367.57 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Equipment. 367.57... Property Instructions § 367.57 Equipment. (a) The cost of equipment chargeable to the service company property accounts, unless otherwise indicated in the text of an equipment account, includes the related net...

  18. 22 CFR 518.34 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Equipment. 518.34 Section 518.34 Foreign... Property Standards § 518.34 Equipment. (a) Title to equipment acquired by a recipient with Federal funds... equipment acquired with Federal funds to provide services to non-Federal outside organizations for a fee...

  19. 46 CFR 197.460 - Diving equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Diving equipment. 197.460 Section 197.460 Shipping COAST... GENERAL PROVISIONS Commercial Diving Operations Periodic Tests and Inspections of Diving Equipment § 197.460 Diving equipment. The diving supervisor shall insure that the diving equipment designated for use...

  20. 40 CFR 46.225 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Equipment. 46.225 Section 46.225... After the Fellowship § 46.225 Equipment. (a) If EPA authorizes you to purchase equipment (see § 46.140(b)) and the equipment retains a fair market value of more than $5,000, you must request disposition...

  1. 27 CFR 19.272 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Equipment. 19.272 Section... THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Construction, Equipment and Security § 19.272 Equipment. The proprietor shall provide equipment suitable for the operations conducted on the distilled spirits...

  2. 43 CFR 12.934 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Equipment. 12.934 Section 12.934 Public....934 Equipment. (a) Title to equipment acquired by a recipient with Federal funds shall vest in the recipient, subject to conditions of this section. (b) The recipient shall not use equipment acquired with...

  3. 50 CFR 260.102 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Equipment. 260.102 Section 260.102... Basis 1 § 260.102 Equipment. All equipment used for receiving, washing, segregating, picking, processing... and effective bactericidal treatment. Insofar as is practicable, all such equipment shall be made of...

  4. 45 CFR 74.34 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Equipment. 74.34 Section 74.34 Public Welfare... COMMERCIAL ORGANIZATIONS Post-Award Requirements Property Standards § 74.34 Equipment. (a) Title to equipment... section. (b)(1) The recipient shall not use equipment acquired with HHS funds to provide services to non...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that naturally exist within the body while you ... chemical changes in the tissues. As the hydrogen atoms return to their usual alignment, they emit different ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that naturally exist within the body while ... any chemical changes in the tissues. As the hydrogen atoms return to their usual alignment, they emit ...

  7. TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI

  8. Agreement of mammographic measures of volumetric breast density to MRI.

    Directory of Open Access Journals (Sweden)

    Jeff Wang

    Full Text Available Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known.To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population.Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume.Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2 values ranging from 0.40 (log fibroglandular volume to 0.91 (total breast volume. Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63, but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume.Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  9. Dental CBCT equipment and performance issues.

    Science.gov (United States)

    Horner, K; Jacobs, R; Schulze, R

    2013-02-01

    Dental cone beam computed tomography (CBCT), also known as digital volumetric tomography was developed in the late 1990s and is now increasingly available in clinical practice. It can provide high resolution cross-sectional images of teeth and the maxillofacial region with applications in all branches of dentistry. As a new imaging modality, there were no established suspension levels at a European level. A literature review, encompassing scientific, professional publications and existing national guidelines was performed in an attempt to develop a set of suspension levels for dental CBCT, using additional expert opinion from the members of the European Academy of dento-maxillo-facial radiology. A limited set of suspension levels has been devised for aspects of the X-ray tube and generator, dosimetry, field-of-view, alignment and image quality. These should be kept under review in the light of growing experience of testing equipment in practice.

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... any recent surgeries. Some conditions, such as severe kidney disease, may prevent you from being given gadolinium ... an MRI. If you have a history of kidney disease or liver transplant, it will be necessary ...

  11. MRI and low back pain

    Science.gov (United States)

    ... this page, please enable JavaScript. Back pain and sciatica are common health complaints. Almost everyone has back ... Back Pain Read more MRI Scans Read more Sciatica Read more A.D.A.M., Inc. is ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the brain) ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be removed. MRI exams generally include multiple runs (sequences), some of which may last several minutes. The ... You may be able to relax between imaging sequences, but will be asked to maintain your position ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Examples include but are not limited to: artificial heart valves implanted drug infusion ports artificial limbs or ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... you have a history of kidney disease or liver transplant, it will be necessary to perform a blood ... procedure work? Unlike conventional x-ray examinations and computed tomography (CT) scans, MRI does not utilize ionizing radiation. ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for Head and ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... from the contrast material, including nausea, headache and pain at the site of injection. Similarly, patients are ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an IV line, into a vein in your hand or arm. A saline solution may be used ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... very rare occasions, a few patients experience side effects from the contrast material, including nausea, headache and ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... can help diagnose conditions such as: brain tumors stroke infections developmental anomalies hydrocephalus — dilatation of fluid spaces ... MRA page for more information. MRI can detect stroke at a very early stage by mapping the ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic ... very early stage by mapping the motion of water molecules in the tissue. This water motion, known ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... period is necessary. You may resume your usual activities and normal diet immediately after the exam. On ... that time the imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... to detect and identify any metal objects. In general, metal objects used in orthopedic surgery pose no ... units provide very high quality images for many types of exams. Older open MRI units may not ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... you have any devices or metal in your body. Guidelines about eating and drinking before your exam ... soft tissues, bone and virtually all other internal body structures. MRI does not use ionizing radiation (x- ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... devices or metal in your body. Guidelines about eating and drinking before your exam vary between facilities. ... fitting and has no metal fasteners. Guidelines about eating and drinking before an MRI exam vary with ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... you should let the radiologist know about them. Parents or family members who accompany patients into the ... intercom. Many MRI centers allow a friend or parent to stay in the room as long as ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI. If you have a history of kidney disease or liver transplant, it will be necessary to perform a blood test to determine whether the kidneys are functioning adequately. Women ... Images related to Magnetic ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... not use ionizing radiation and may require an injection of a contrast material called gadolinium, which is ... MRI examinations may require you to receive an injection of contrast material into the bloodstream. The radiologist , ...

  10. MRI appearance of muscle denervation

    Energy Technology Data Exchange (ETDEWEB)

    Kamath, S. [University Hospital of Wales, Department of Radiology, Cardiff (United Kingdom); Venkatanarasimha, N.; Walsh, M.A.; Hughes, P.M. [Derriford Hospital, Department of Radiology, Plymouth (United Kingdom)

    2008-05-15

    Muscle denervation results from a variety of causes including trauma, neoplasia, neuropathies, infections, autoimmune processes and vasculitis. Traditionally, the diagnosis of muscle denervation was based on clinical examination and electromyography. Magnetic resonance imaging (MRI) offers a distinct advantage over electromyography, not only in diagnosing muscle denervation, but also in determining its aetiology. MRI demonstrates characteristic signal intensity patterns depending on the stage of muscle denervation. The acute and subacutely denervated muscle shows a high signal intensity pattern on fluid sensitive sequences and normal signal intensity on T1-weighted MRI images. In chronic denervation, muscle atrophy and fatty infiltration demonstrate high signal changes on T1-weighted sequences in association with volume loss. The purpose of this review is to summarise the MRI appearance of denervated muscle, with special emphasis on the signal intensity patterns in acute and subacute muscle denervation. (orig.)

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... in the first three to four months of pregnancy unless the potential benefit from the MRI exam is assumed to outweigh the potential risks. Pregnant women should not receive injections of gadolinium ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... within a vein) top of page How should I prepare? You may be asked to wear a ... total exam time. top of page What will I experience during and after the procedure? Most MRI ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... surgery pose no risk during MRI. However, a recently placed artificial joint may require the use of ... maintain your position without movement as much as possible. You will usually be alone in the exam ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... activated. Some centers provide earplugs, while others use headphones to reduce the intensity of the sounds made ... Children will be given appropriately sized earplugs or headphones during the exam. MRI scanners are air-conditioned ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to ... MRI exam, a physician, nurse or technologist will insert an intravenous (IV) catheter, also known as an ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a physician, nurse or technologist will insert an intravenous (IV) catheter, also known as an IV line, ... images in case additional images are needed. Your intravenous line will be removed. MRI exams generally include ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should always ... metal objects. In general, metal objects used in orthopedic surgery pose no risk during MRI. However, a ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the eyes are particularly important because they may move during the scan, possibly causing blindness. Dyes used in tattoos may contain iron and could heat up during an MRI scan, but this is rare. ...