WorldWideScience

Sample records for exhaust valves

  1. High Temperature Resistant Exhaust Valve Spindle

    DEFF Research Database (Denmark)

    Bihlet, Uffe Ditlev

    of the engine, new high temperature alloys are required for a specific engine component, the exhaust valve spindle. Two alloys are used for an exhaust valve spindle; one for the bottom of the spindle, and one for the spindle seat. Being placed in the exhaust gas stream, combustion products such as V2O5 and Na2...

  2. Exhaust gas bypass valve control for thermoelectric generator

    Science.gov (United States)

    Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan

    2012-09-04

    A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

  3. Electromagnetic Exhaust Valve Event Optimization for Enhancing Gasoline Engine Performance

    Directory of Open Access Journals (Sweden)

    Fan Xinyu

    2017-01-01

    Full Text Available Variable exhaust valve events have the potential to further improve the engine power output, fuel economy and decrease the NOX emissions. Based on the moving coil electromagnetic valve train applied to engine exhaust system, effects of variable exhaust valve events are analyzed in detail and the optimization approaches are carried out. Also with the fully variable intake and exhaust valve train, different internal EGR strategies can be achieved and the contrastive analyses are carried out between combustion chamber recirculation and exhaust port recirculation strategies at same operational condition. Results show that, the optimal exhaust valve opening motion can strengthen both power performance and fuel economy at engine part loads. And two principal EGR strategies are applied in a good combination under variable engine loads. At the engine speed of 2000 r/min, BMEP is about 0.3 MPa and with 30%~35% exhaust port recirculation rate, the BSFC and NOX emissions have decrease over 10% and 85% respectively compare with initial condition.

  4. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  5. Feasibility study of submarine diesel exhaust valve interspace coating application

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, W.; Zhou, M.; Bibby, D.; Huang, J.

    2008-05-15

    This document described a feasibility study conducted to evaluate surface coating systems applied to the surface of a diesel exhaust valve interspace on a VICTORIA Class submarine. A series of laboratory studies were conducted to determine the physical characteristics of the coatings, which will be subjected to high service temperatures, diesel exhaust gas, and seawater. The valves were made of Q1N steel castings. The surface coatings were designed to provide corrosion resistance and thermal protection to the valves. As part of the study, a survey was conducted on various state-of-the-art surface coating systems. Coatings were rated on their ability to protect the Q10 steel surface from corrosion, high temperatures and seawater. An additional requirement was that the coatings should not produce high amounts of hydrogen. Plating trials were conducted with a nickel-based alloy (Ni-Cu-P) placed on Q1N steel substrates with a hypophosphite reducing agent. The results of X-ray diffraction (XRD) analyses suggested that the coatings can also be used to protect the external surfaces of various submarine components. 54 refs., 4 tabs., 10 figs.

  6. A WEAR MODEL FOR DIESEL ENGINE EXHAUST VALVES

    Energy Technology Data Exchange (ETDEWEB)

    Blau, Peter Julian [ORNL

    2009-11-01

    The work summarized here comprises the concluding effort of a multi-year project, funded by the U.S. Department of Energy, Office of Vehicle Technologies. It supports the development of a better understanding of advanced diesel engine designs in which enhanced power density, energy efficiency, and emissions control place increasing demands upon the durability of engine materials. Many kinds of metallic alloys are used in engines depending on the operating stresses, temperatures, and chemical environments. Exhaust valves, for example, are subjected to high temperatures and repetitive surface contacts that place demands on durability and frictional characteristics of the materials. Valves must continue to seal the combustion chamber properly for thousands of hours of cyclic engine operation and under varying operating conditions. It was the focus of this effort to understand the wear processes in the valve-seat area and to develop a model for the surface deformation and wear of that important interface. An annotated bibliography is provided to illustrate efforts to understand valve wear and to investigate the factors of engine operation that affect its severity and physical manifestation. The project for which this modeling effort was the final task, involved construction of a high-temperature repetitive impact test system as well as basic tribology studies of the combined processes of mechanical wear plus oxidation at elevated temperatures. Several publications resulted from this work, and are cited in this report. The materials selected for the experimental work were high-performance alloys based on nickel and cobalt. In some cases, engine-tested exhaust valves were made available for wear analysis and to ensure that the modes of surface damage produced in experiments were simulative of service. New, production-grade exhaust valves were also used to prepare test specimens for experimental work along with the other alloy samples. Wear analysis of valves and seats

  7. The two-stroke poppet valve engine. Part 1: Intake and exhaust ports flow experimental assessments

    Science.gov (United States)

    Kamili Zahidi, M.; Razali Hanipah, M.; Ramasamy, D.; Noor, M. M.; Kadirgama, K.; Rahman, M. M.

    2017-10-01

    A two-stroke poppet valve engine is developed to overcome the common problems in conventional two-stroke engine designs. However, replacing piston control port with poppet valve will resulted different flow behaviour. This paper is looking at experimental assessment on a two-stroke poppet valve engine configuration to investigate the port flow performance. The aims are to evaluate the intake and exhaust coefficient of discharge and assess the twostroke capability of the cylinder head. The results has shown comparable coefficient of discharge values as production engine for the intake while the exhaust has higher values which is favourable for the two-stroke cycle operation.

  8. Strength and fatigue of NT551 silicon nitride and NT551 diesel exhaust valves

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, M.J.; Werezczak, A.A.; Kirkland, T.P.; Breder, K.

    2000-02-01

    The content of this report is excerpted from Mark Andrew's Ph.D. Thesis (Andrews, 1999), which was funded by a DOE/OTT High Temperature Materials Laboratory Graduate Fellowship. It involves the characterization of NT551 and valves fabricated with it. The motivations behind using silicon nitride (Si{sub 3}N{sub 4}) as an exhaust valve for a diesel engine are presented in this section. There are several economic factors that have encouraged the design and implementation of ceramic components for internal combustion (IC) engines. The reasons for selecting the diesel engine valve for this are also presented.

  9. In-situ hot corrosion testing of candidate materials for exhaust valve spindles

    DEFF Research Database (Denmark)

    Bihlet, Uffe; Hoeg, Harro A.; Dahl, Kristian Vinter

    2011-01-01

    used, exhaust valve spindles in marine diesel engines are subjected to high temperatures and stresses as well as molten salt induced corrosion. To investigate candidate materials for future designs which will involve the HIP process, a spindle with Ni superalloy material samples inserted in a HIPd Ni49...

  10. Analysis on fuel economy improvement and exhaust emission reduction in a two-stroke engine by using an exhaust valve

    Energy Technology Data Exchange (ETDEWEB)

    Asai, Masahiro; Kurosaki, Takaharu; Okada, Kazunori

    1995-12-31

    A timing controlled auto-ignition name ``AR combustion`` could improve irregular combustion in the part load operation of conventional two-stroke engines. Their previous papers have suggested its idea and the drastic improvements in fuel consumption and HC emission proven through a bench experiments. This time, form a concept that improvements of a two-stroke engine should be done maintaining its original advantages, an AR combustion engine was developed by using a simple exhaust valve and maintaining engine`s original power output. This engine was mounted on a motorcycle and experimented in the ``Dakar rally``. As the results, good fuel economies exceeding a four-stroke rally model, excellent driveability and durability were proven, because of the improvement in the combustion and engine`s potential for the downsizing. The AR combustion engine, consequently, has good prospects for the practical use.

  11. Strength and Fatigue of NT551 Silicon Nitride and NT551 Diesel Exhaust Valves

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, M.J.; Wereszczak, A.A.; Kirkland, T.P.; Breder, K.

    2000-02-01

    The content of this report is excerpted from Mark Andrew's Ph.D. Thesis (Andrews, 1999), which was funded by a DOEYOTT High Temperature Materials Laboratory Graduate Fellowship. It involves the characterization of NT551 and valves fabricated with it. Greater detail of the described issues may be found in that reference or through communications with Andrew Wereszczak.

  12. An Approach to the Prototyping of an Optimized Limited Stroke Actuator to Drive a Low Pressure Exhaust Gas Recirculation Valve

    Directory of Open Access Journals (Sweden)

    Christophe Gutfrind

    2016-05-01

    Full Text Available The purpose of this article is to describe the design of a limited stroke actuator and the corresponding prototype to drive a Low Pressure (LP Exhaust Gas Recirculation (EGR valve for use in Internal Combustion Engines (ICEs. The direct drive actuator topology is an axial flux machine with two air gaps in order to minimize the rotor inertia and a bipolar surface-mounted permanent magnet in order to respect an 80° angular stroke. Firstly, the actuator will be described and optimized under constraints of a 150 ms time response, a 0.363 N·m minimal torque on an angular range from 0° to 80° and prototyping constraints. Secondly, the finite element method (FEM using the FLUX-3D® software (CEDRAT, Meylan, France will be used to check the actuator performances with consideration of the nonlinear effect of the iron material. Thirdly, a prototype will be made and characterized to compare its measurement results with the analytical model and the FEM model results. With these electromechanical behavior measurements, a numerical model is created with Simulink® in order to simulate an EGR system with this direct drive actuator under all operating conditions. Last but not least, the energy consumption of this machine will be estimated to evaluate the efficiency of the proposed EGR electromechanical system.

  13. The two-stroke poppet valve engine. Part 2: Numerical investigations of intake and exhaust flow behaviour

    Science.gov (United States)

    Kamili Zahidi, M.; Razali Hanipah, M.

    2017-10-01

    A two-stroke poppet valve engine is developed to overcome the common problems in conventional two-stroke engine designs. However, replacing piston control port with poppet valve will resulted different flow behaviour. This paper presents the model and simulation result of three-dimensional (3D) port flow investigation of a two-stroke poppet valve engine. The objective of the investigation is to conduct a numerical investigation on port flow performance of two-stroke poppet valve engine and compare the results obtained from the experimental investigation. The model is to be used for the future numerical study of the engine. The volume flow rate results have been compared with the results obtained experimentally as presented in first part of this paper. The model has shown good agreement in terms of the flow rate at initial and final valve lifts but reduced by about 50% during half-lift region.

  14. Numerical Evaluation of an Ejector-Enhanced Resonant Pulse Combustor with a Poppet Inlet Valve and a Converging Exhaust Nozzle

    Science.gov (United States)

    Yungster, Shaye; Paxson, Daniel E.; Perkins, Hugh D.

    2016-01-01

    A computational investigation of a pressure-gain combustor system for gas turbine applications is presented. The system consists of a valved pulse combustor and an ejector, housed within a shroud. The study focuses on two enhancements to previous models, related to the valve and ejector components. First, a new poppet inlet valve system is investigated, replacing the previously used reed valve configuration. Secondly, a new computational approach to approximating the effects of choked turbine inlet guide vanes present immediately downstream of the Ejector-Enhanced Resonant Pulse Combustor (EERPC) is investigated. Instead of specifying a back pressure at the EERPC exit boundary (as was done in previous studies) the new model adds a converging-diverging (CD) nozzle at the exit of the EERPC. The throat area of the CD nozzle can be adjusted to obtain the desired back pressure level and total mass flow rate. The results presented indicate that the new poppet valve configuration performs nearly as well as the original reed valve system, and that the addition of the CD nozzle is an effective method to approximate the exit boundary effects of a turbine present downstream of the EERPC. Furthermore, it is shown that the more acoustically reflective boundary imposed by a nozzle as compared to a constant pressure surface does not significantly affect operation or performance.

  15. Engine including hydraulically actuated valvetrain and method of valve overlap control

    Science.gov (United States)

    Cowgill, Joel [White Lake, MI

    2012-05-08

    An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

  16. Exhaust bypass flow control for exhaust heat recovery

    Science.gov (United States)

    Reynolds, Michael G.

    2015-09-22

    An exhaust system for an engine comprises an exhaust heat recovery apparatus configured to receive exhaust gas from the engine and comprises a first flow passage in fluid communication with the exhaust gas and a second flow passage in fluid communication with the exhaust gas. A heat exchanger/energy recovery unit is disposed in the second flow passage and has a working fluid circulating therethrough for exchange of heat from the exhaust gas to the working fluid. A control valve is disposed downstream of the first and the second flow passages in a low temperature region of the exhaust heat recovery apparatus to direct exhaust gas through the first flow passage or the second flow passage.

  17. Two phase exhaust for internal combustion engine

    Science.gov (United States)

    Vuk, Carl T [Denver, IA

    2011-11-29

    An internal combustion engine having a reciprocating multi cylinder internal combustion engine with multiple valves. At least a pair of exhaust valves are provided and each supply a separate power extraction device. The first exhaust valves connect to a power turbine used to provide additional power to the engine either mechanically or electrically. The flow path from these exhaust valves is smaller in area and volume than a second flow path which is used to deliver products of combustion to a turbocharger turbine. The timing of the exhaust valve events is controlled to produce a higher grade of energy to the power turbine and enhance the ability to extract power from the combustion process.

  18. Valve Disease

    Science.gov (United States)

    ... See also on this site: Diseases of the Mitral Valve Diseases of the Aortic Valve Diseases of the Tricuspid ... most invasive option for the treatment of valve disease. During surgery, ... defects of the mitral valve. Replacement is used to treat any diseased ...

  19. Heart valve surgery

    Science.gov (United States)

    Valve replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... can relieve your symptoms and prolong your life. Mechanical heart valves do not often fail. However, blood clots can ...

  20. Variable Valve Actuation

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey Gutterman; A. J. Lasley

    2008-08-31

    Many approaches exist to enable advanced mode, low temperature combustion systems for diesel engines - such as premixed charge compression ignition (PCCI), Homogeneous Charge Compression Ignition (HCCI) or other HCCI-like combustion modes. The fuel properties and the quantity, distribution and temperature profile of air, fuel and residual fraction in the cylinder can have a marked effect on the heat release rate and combustion phasing. Figure 1 shows that a systems approach is required for HCCI-like combustion. While the exact requirements remain unclear (and will vary depending on fuel, engine size and application), some form of substantially variable valve actuation is a likely element in such a system. Variable valve actuation, for both intake and exhaust valve events, is a potent tool for controlling the parameters that are critical to HCCI-like combustion and expanding its operational range. Additionally, VVA can be used to optimize the combustion process as well as exhaust temperatures and impact the after treatment system requirements and its associated cost. Delphi Corporation has major manufacturing and product development and applied R&D expertise in the valve train area. Historical R&D experience includes the development of fully variable electro-hydraulic valve train on research engines as well as several generations of mechanical VVA for gasoline systems. This experience has enabled us to evaluate various implementations and determine the strengths and weaknesses of each. While a fully variable electro-hydraulic valve train system might be the 'ideal' solution technically for maximum flexibility in the timing and control of the valve events, its complexity, associated costs, and high power consumption make its implementation on low cost high volume applications unlikely. Conversely, a simple mechanical system might be a low cost solution but not deliver the flexibility required for HCCI operation. After modeling more than 200 variations of

  1. Three-dimensional numerical simulation of the exhaust stroke of a single-cylinder four-stroke ICE

    Energy Technology Data Exchange (ETDEWEB)

    Ogorevc, T.; Sekavcnik, M. [Ljubljana Univ. (Slovenia). Lab. for Heat and Power; Katrasnik, T. [Ljubljana Univ. (Slovenia). Lab. for Internal Combustion Engines; Zun, I. [Ljubljana Univ. (Slovenia). Lab. for Fluid Dynamics and Thermodynamics

    2009-09-15

    In this paper an extensive CFD simulation of the exhaust stroke of a single-cylinder fourstroke ICE, including the entire exhaust manifold is described. Guidelines for the implementation of the full threedimensional model of the discussed process are included. The simulation involves the time-dependent flow of exhaust gases through the exhaust valve and the flow dynamics within the 2.2-m-long, straight exhaust pipe during the period when the valve is closed. Also the intake port with the intake valve is being coupled during the valves' overlap period. The model geometry corresponds exactly to the actual engine geometry. The movement of the mesh follows the measured kinematics of the piston and the valves. The data obtained from the experimental environment was used for both the initialization and the validation of the computations. It was found that the phenomena affecting the dynamics of the exhaust flow are extremely three-dimensional and should be treated as such. In particular, the flow through the exhaust valve and the heat transfer along the exhaust pipe were influenced greatly by the effects of cold, fresh air breaking into the exhaust pipe in the period after the EVC. The presented study is the basis for future three-dimensional investigations of the entropy-generation rate along the exhaust system, including the exhaust valve. (orig.)

  2. Air flow quality analysis of modenas engine exhaust system

    Science.gov (United States)

    Shahriman A., B.; Mohamad Syafiq A., K.; Hashim, M. S. M.; Razlan, Zuradzman M.; Khairunizam W. A., N.; Hazry, D.; Afendi, Mohd; Daud, R.; Rahman, M. D. Tasyrif Abdul; Cheng, E. M.; Zaaba, S. K.

    2017-09-01

    The simulation process being conducted to determine the air flow effect between the original exhaust system and modified exhaust system. The simulations are conducted to investigate the flow distribution of exhaust gases that will affect the performance of the engine. The back flow pressure in the original exhaust system is predicted toward this simulation. The design modification to the exhaust port, exhaust pipe, and exhaust muffler has been done during this simulation to reduce the back flow effect. The new designs are introduced by enlarging the diameter of the exhaust port, enlarge the diameter of the exhaust pipe and created new design for the exhaust muffler. Based on the result obtained, there the pulsating flow form at the original exhaust port that will increase the velocity and resulting the back pressure occur. The result for new design of exhaust port, the velocity is lower at the valve guide in the exhaust port. New design muffler shows that the streamline of the exhaust flow move smoothly compare to the original muffler. It is proved by using the modification exhaust system, the back pressure are reduced and the engine performance can be improve.

  3. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  4. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  5. Effects of High Temperature on the Microstructure of Automotive Engine Valves

    Directory of Open Access Journals (Sweden)

    Ajay Pandey

    2014-03-01

    Full Text Available In this paper, failures of automobile valves are considered and discussed. The changes in microstructures of valves were studied and analyzed with the aid of a Scanning Electron Microscope (SEM. Specimens were prepared out of failed engine valves whereas new valves were also analyzed for the sake of comparison. This was done by image analysis of specimens of failed and new valves at adequate magnification. The benchmarking of microstructures of failed valves v/s new valves revealed that the size of grains, grain boundaries, and distribution of carbide particles across the material matrix is affected by high temperature conditions and the effects are more severe for exhaust valves. The microstructure of valve material shows discernible changes after operating at high temperatures. The grain size of the material also changes at high temperature, thus resulting in a reduction in the hardness of the valve material which, in turn, causes more wear.

  6. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  7. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    to what extent it represents a new blueprint for organization design, despite it being consistent with an “egalitarian Zeitgeist” (Puranam, 2014). In fact, managerial authority may be of increasing importance rather than the opposite (Guadalupe, Li, & Wulf, 2015). Thus, Valve is, and will remain...

  8. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  9. Butterfly valve. Spjeldventil

    Energy Technology Data Exchange (ETDEWEB)

    Cupedo, D.J.

    1984-02-06

    Butterfly valve comprising a body and a valve seat arranged therein, on which a valve member is supported. The valve member comprises an operating rod and the assembly of valve member and operating rod has a fixed pivot point at the bottom of the body. The operating rod can be moved by means of pins movable in grooves and slots in such a manner that when the valve is opened the valve member first pivots about the pivot point to lift the valve member from the seat and subsequently rotates about the pivot point to fully open the valve. 12 drawings.

  10. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  11. Aortic Valve Stenosis

    Science.gov (United States)

    ... rapid, fluttering heartbeat Not eating enough (mainly in children with aortic valve stenosis) Not gaining enough weight (mainly in children with aortic valve stenosis) The heart-weakening effects of aortic valve stenosis ...

  12. What Is Heart Valve Disease?

    Science.gov (United States)

    ... Heart Valves Sometimes heart valves can’t be repaired and must be replaced. This surgery involves removing the faulty valve and replacing it with a man-made or biological valve. Biological valves are made ...

  13. Exhaustion from prolonged gambling

    Directory of Open Access Journals (Sweden)

    Fatimah Lateef

    2013-01-01

    Full Text Available Complaints of fatigue and physical exhaustion are frequently seen in the acute medical setting, especially amongst athletes, army recruits and persons involved in strenuous and exertional physical activities. Stress-induced exhaustion, on the other hand, is less often seen, but can present with very similar symptoms to physical exhaustion. Recently, three patients were seen at the Department of Emergency Medicine, presenting with exhaustion from prolonged involvement in gambling activities. The cases serve to highlight some of the physical consequences of prolonged gambling.

  14. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  15. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  16. Mitral valve regurgitation

    Science.gov (United States)

    ... around the valve. You are at risk for mitral valve regurgitation if you have: Coronary heart disease and high blood pressure Infection of the heart valves Mitral valve prolapse (MVP) Rare conditions, such as untreated syphilis or Marfan ... heart disease. This is a complication of untreated strep throat ...

  17. Tissue engineered aortic valve

    OpenAIRE

    Dohmen, P M

    2012-01-01

    Several prostheses are available to replace degenerative diseased aortic valves with unique advantages and disadvantages. Bioprotheses show excellent hemodynamic behavior and low risk of thromboembolic complications, but are limited by tissue deterioration. Mechanical heart valves have extended durability, but permanent anticoagulation is mandatory. Tissue engineering created a new generation heart valve, which overcome limitations of biological and mechanical heart valves due to remodelling,...

  18. Hyperventilation and exhaustion syndrome.

    Science.gov (United States)

    Ristiniemi, Heli; Perski, Aleksander; Lyskov, Eugene; Emtner, Margareta

    2014-12-01

    Chronic stress is among the most common diagnoses in Sweden, most commonly in the form of exhaustion syndrome (ICD-10 classification - F43.8). The majority of patients with this syndrome also have disturbed breathing (hyperventilation). The aim of this study was to investigate the association between hyperventilation and exhaustion syndrome. Thirty patients with exhaustion syndrome and 14 healthy subjects were evaluated with the Nijmegen Symptom Questionnaire (NQ). The participants completed questionnaires about exhaustion, mental state, sleep disturbance, pain and quality of life. The evaluation was repeated 4 weeks later, after half of the patients and healthy subjects had engaged in a therapy method called 'Grounding', a physical exercise inspired by African dance. The patients reported significantly higher levels of hyperventilation as compared to the healthy subjects. All patients' average score on NQ was 26.57 ± 10.98, while that of the healthy subjects was 15.14 ± 7.89 (t = -3.48, df = 42, p exhaustion (Karolinska Exhaustion Scale KES r = 0.772, p exhaustion scores and scores of depression and anxiety. The conclusion is that hyperventilation is common in exhaustion syndrome patients and that it can be reduced by systematic physical therapy such as Grounding. © 2013 The Authors. Scandinavian Journal of Caring Sciences published by John Wiley & Sons Ltd on behalf of Nordic College of Caring Science.

  19. Local Exhaust Ventilation

    DEFF Research Database (Denmark)

    Madsen, Ulla; Breum, N. O.; Nielsen, Peter V.

    Capture efficiency of a local exhaust system, e.g. a kitchen hood, should include only contaminants being direct captured. In this study basic concepts of local exhaust capture efficiency are given, based on the idea of a control box. A validated numerical model is used for estimation...

  20. Immune Exhaustion and Transplantation.

    Science.gov (United States)

    Sanchez-Fueyo, A; Markmann, J F

    2016-07-01

    Exhaustion of lymphocyte function through chronic exposure to a high load of foreign antigen is well established for chronic viral infection and antitumor immunity and has been found to be associated with a distinct molecular program and characteristic cell surface phenotype. Although exhaustion has most commonly been studied in the context of CD8 viral responses, recent studies indicate that chronic antigen exposure may affect B cells, NK cells and CD4 T cells in a parallel manner. Limited information is available regarding the extent of lymphocyte exhaustion development in the transplant setting and its impact on anti-graft alloreactivity. By analogy to the persistence of a foreign virus, the large mass of alloantigen presented by an allograft in chronic residence could provide an ideal setting for exhausting donor-reactive T cells. The extent of T cell exhaustion occurring with various allografts, the kinetics of its development, whether exhaustion is influenced positively or negatively by different immunosuppressants, and the impact of exhaustion on graft survival and tolerance development remains a fertile area for investigation. Harnessing or encouraging the natural processes of exhaustion may provide a novel means to promote graft survival and transplantation tolerance. © Copyright 2016 The American Society of Transplantation and the American Society of Transplant Surgeons.

  1. Risks for Heart Valve Problems

    Science.gov (United States)

    ... Thromboembolism Aortic Aneurysm More Risks for Heart Valve Problems Updated:Jan 18,2017 Who is at risk ... content was last reviewed May 2016. Heart Valve Problems and Disease • Home • About Heart Valves • Heart Valve ...

  2. Living with Heart Valve Disease

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  3. What Causes Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  4. NK Cell Exhaustion

    Science.gov (United States)

    Bi, Jiacheng; Tian, Zhigang

    2017-01-01

    Natural killer cells are important effector lymphocytes of the innate immune system, playing critical roles in antitumor and anti-infection host defense. Tumor progression or chronic infections, however, usually leads to exhaustion of NK cells, thus limiting the antitumor/infection potential of NK cells. In many tumors or chronic infections, multiple mechanisms might contribute to the exhaustion of NK cells, such as dysregulated NK cell receptors signaling, as well as suppressive effects by regulatory cells or soluble factors within the microenvironment. Better understanding of the characteristics, as well as the underlying mechanisms of NK cell exhaustion, not only should increase our understanding of the basic biology of NK cells but also could reveal novel NK cell-based antitumor/infection targets. Here, we provide an overview of our current knowledge on NK cell exhaustion in tumors, and in chronic infections. PMID:28702032

  5. Unemployment Benefit Exhaustion

    DEFF Research Database (Denmark)

    Filges, Trine; Pico Geerdsen, Lars; Knudsen, Anne-Sofie Due

    2015-01-01

    This systematic review studied the impact of exhaustion of unemployment benefits on the exit rate out of unemployment and into employment prior to benefit exhaustion or shortly thereafter. Method: We followed Campbell Collaboration guidelines to prepare this review, and ultimately located 12...... studies for final analysis and interpretation. Twelve studies could be included in the data synthesis. Results: We found clear evidence that the prospect of exhaustion of benefits results in a significantly increased incentive for finding work. Discussion: The theoretical suggestion that the prospect...... of exhaustion of benefits results in an increased incentive for finding work has been confirmed empirically by measures from seven different European countries, the United States, and Canada. The results are robust in the sense that sensitivity analyses evidenced no appreciable changes in the results. We found...

  6. Immune Exhaustion and Transplantation

    National Research Council Canada - National Science Library

    Sanchez‐Fueyo, A; Markmann, J. F

    2016-01-01

    Exhaustion of lymphocyte function through chronic exposure to a high load of foreign antigen is well established for chronic viral infection and antitumor immunity and has been found to be associated...

  7. Influence of the single EGR valve usability on development of the charge directed to individual cylinders of an internal combustion engine

    Directory of Open Access Journals (Sweden)

    Krakowian Konrad

    2017-01-01

    Full Text Available Exhaust gas recirculation systems (EGR, aside to a catalytic converters, are nowadays widely used in piston internal combustion engines to reduce nitrogen oxides (NOx in the exhaust gas. They are characterized in that a portion of exhaust gases from the exhaust manifold is recirculated (via a condenser, and directed to a particular valve. The valve, depending on the current engine load and speed, doses the appropriate amount of exhaust gas into the exhaust manifold. Moreover, its location has a significant impact on the diverse formation of nitrogen oxides and fumes smokiness from the individual cylinders of the engine, which is a result of uneven propagation of exhaust gas into the channels of the intake manifold. This article contains the results of numerical characterized charges formed in symmetrical intake manifold with a centrally–placed EGR valve. Simulations were performed for the original intake system derived from the two-liter, turbocharged VW diesel engine.

  8. Influence of the single EGR valve usability on development of the charge directed to individual cylinders of an internal combustion engine

    Science.gov (United States)

    Krakowian, Konrad; Kaźmierczak, Andrzej; Górniak, Aleksander; Wróbel, Radosław

    2017-11-01

    Exhaust gas recirculation systems (EGR), aside to a catalytic converters, are nowadays widely used in piston internal combustion engines to reduce nitrogen oxides (NOx) in the exhaust gas. They are characterized in that a portion of exhaust gases from the exhaust manifold is recirculated (via a condenser), and directed to a particular valve. The valve, depending on the current engine load and speed, doses the appropriate amount of exhaust gas into the exhaust manifold. Moreover, its location has a significant impact on the diverse formation of nitrogen oxides and fumes smokiness from the individual cylinders of the engine, which is a result of uneven propagation of exhaust gas into the channels of the intake manifold. This article contains the results of numerical characterized charges formed in symmetrical intake manifold with a centrally-placed EGR valve. Simulations were performed for the original intake system derived from the two-liter, turbocharged VW diesel engine.

  9. Optimising BMW four-cylinder two-valve engines Optimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOptimising BMW Four-Cylinder Two-Valve Engines (OpOpt

    Science.gov (United States)

    Flierl, R.; Kramer, F.; Rech, H.; Stanski, U.; Wenzel, M.

    1993-11-01

    In model year 1994, BMW will present two essentially redesigned 4-cylinder, 2-valve engines. BMW has upgraded its 1.6 1 and 1.8 1 2-valve engines using technical features previously reserved for the 4-valve engines, such as knock control system, distributorless semiconductor ignition, variable induction system (DISA) and ribbed V-belt accessory drive, along with measures to reduce power losses, noise levels and exhaust emissions. BMW models equipped with these two engines offer customers improved response characteristics and fuel consumption, as well as reduced emissions and maintenance requirements.

  10. Mitral valve prolapse

    Science.gov (United States)

    ... mitral valve prolapse is called "mitral valve prolapse syndrome," and includes: Chest pain (not caused by coronary artery disease or a heart attack) Dizziness Fatigue Panic attacks Sensation of feeling the heart beat ( palpitations ) ...

  11. Mitral Valve Stenosis

    Science.gov (United States)

    ... valve stenosis include: Rheumatic fever. A complication of strep throat, rheumatic fever can damage the mitral valve. Rheumatic ... children see your doctor for sore throats. Untreated strep throat infections can develop into rheumatic fever. Fortunately, strep ...

  12. Isolated Pulmonary Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hatamizadeh

    2009-06-01

    Full Text Available Infective endocarditis is one of the most severe complications of parenteral drug abuse. The outstanding clinical feature of infective endocarditis in intravenous drug abusers is the high incidence of right-sided valve infection, and the tricuspid valve is involved in 60% to 70% of the cases. We herein report a case of isolated pulmonic valve infective endocarditis with a native pulmonary valve.

  13. A case of SAPIEN XT valve fallen into left ventricle during valve-in-valve transcatheter aortic valve implantation.

    Science.gov (United States)

    Koizumi, Shigeki; Ehara, Natsuhiko; Nishiya, Kenta; Koyama, Tadaaki

    2017-06-24

    Late transcatheter heart valve embolization is a rare but life-threatening complication of transcatheter aortic valve implantation. Surgical intervention is performed for most cases, but some cases were treated by valve-in-valve transcatheter aortic valve implantation. We describe a patient in whom a 29-mm Edwards SAPIEN XT valve migrated into the left ventricular outflow tract 41 days after the initial implantation. We tried to perform valve-in-valve transcatheter aortic valve implantation using a transfemoral approach. As soon as the second transcatheter heart valve touched the first implanted valve, it fell into the left ventricle. Immediate surgical intervention was required. The first valve was removed, and surgical aortic valve replacement was successfully performed. In conclusion, we should choose surgical aortic valve replacement for late transcatheter heart valve embolization. Even if we need to treat by catheter intervention, transapical approach may be better.

  14. Diesel emission reduction using internal exhaust gas recirculation

    Science.gov (United States)

    He, Xin [Denver, CO; Durrett, Russell P [Bloomfield Hills, MI

    2012-01-24

    A method for controlling combustion in a direct-injection diesel engine includes monitoring a crankshaft rotational position of a cylinder of the engine, monitoring an engine load, determining an intake stroke within the cylinder based upon the crankshaft rotational position, and when the engine load is less than a threshold engine load, opening an exhaust valve for the cylinder during a portion of the intake stroke.

  15. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  16. Main Oxidizer Valve Design

    Science.gov (United States)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  17. Aerodynamic Control of Exhaust

    DEFF Research Database (Denmark)

    Hyldgård, Carl-Erik

    In the autumn of 1985 the Unive!Sity of Aalborg was approached by the manufacturer C. P. Aaberg, who had obtained aerodynilmic control of the exhaust by means of injection. The remaining investigations comprising optimizations of the system with regard to effect, consumption, requirements...

  18. Visualisation of Gasoline and Exhaust Gases Distribution in a 4-Valve Si Engine; Effects of Stratification on Combustion and Pollutants Visualisation de la répartition du carburant et des gaz brûlés dans un moteur à 4 soupapes à allumage commandé ; effet de la stratification sur la combustion et les polluants

    Directory of Open Access Journals (Sweden)

    Deschamps B.

    2006-12-01

    Full Text Available sAn indirect method to map the burned gases in SI engine has been developed. It is based on visualisation by Laser Induced Fluorescence of the unburned mixture seeded with biacetyl. Both internally and externally recirculated burned gases are monitored. This diagnostic is complementary to the LIF technique applied to measure the gasoline distribution. These LIF gasoline and burned gases measurements are applied in a 4-valve optical access SI engine for a large range of operating conditions. These include variations of both fuel injection and burned gas recirculation modes causing different types of stratification leading to very distinct heat release and exhaust emissions characteristics. Tumble level and spark location are also modified. The observation of the actual stratification in the engine forms a sound basis explanation of the engine performance. Parameters allowing an optimisation of NOx and HC levels can be inferred, and in particular the effectiveness of recirculation and fuel injection strategies. The conclusions are confirmed by measurements in a single engine cylinder conventional head with the same geometry. Une méthode indirecte pour cartographier les gaz brûlés dans un moteur à allumage commandé a été développée. Elle est fondée sur une visualisation à partir de la fluorescence induite par laser (LIF du mélange air-carburant non brûlé et ensemencé avec du biacétyl. Les gaz brûlés provenant à la fois des recirculations internes et externes sont observés. Ce type de diagnostic est complémentaire des techniques de LIF utilisées pour observer la distribution du carburant. Ces mesures de concentration sont réalisées dans un moteur à 4 soupapes avec accès optiques, pour une gamme étendue de conditions opératoires. Celles-ci comprennent des variations des modes d'injection du carburant et des modes de recirculation des gaz brûlés, provoquant ainsi différents types de stratifications qui correspondent

  19. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  20. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  1. Modeling the Mitral Valve

    Science.gov (United States)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  2. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  3. Replaceable valve seat

    Science.gov (United States)

    Jordan, Raymond W.

    1992-01-01

    A valve with an O-ring, a disk seal, and a replaceable valve seat is presented. A groove in the bottom on the valve seat flange forms an inner and outer drip ledge with the inner and outer periphery of the flange. If leakage occurs at the valve seat O-ring, fluid droplets will form on the out drip ledge. If leakage occurs at the disk seal, fluid droplets will form on the inner drip ledge. A visual inspection of these drip ledges through an access port, or by a borescope placed in an inspection port, can discriminate between a leak which originates in the O-ring and a leak which originates in the disk seal. When conventional replaceable valve seats leak, fluid droplets form at the bottom on the valve seat. In the present invention, such a valve seat is modified by machining a groove on the bottom surface of the valve seat flange. This groove and the inner and outer surfaces of the flange intersect and form drip ledges. If leakage occurs at the valve seat seal, shown as an O-ring in the preferred embodiment, fluid droplets will form on the outer drip ledge. If leakage occurs at the valve disk seal, fluid droplets will form on the inner drip ledge. The drip ledges can be inspected either through an access port or by passing a borescope through a small inspection port in the valve case. Visual inspection of the bottom on the drip ledge will positively identify the required repair action.

  4. Valve reconstruction for congenital mitral valve disease.

    Science.gov (United States)

    Quinonez, Luis G; Del Nido, Pedro J

    2015-01-01

    The surgical treatment of mitral valve disease in children is a challenging problem. Mitral stenosis and regurgitation may occur in isolation or together. Mitral valve repair is almost always preferable to replacement. Mitral valve replacement is not an ideal alternative to repair due to limitations of size, growth, structural valve degeneration, anticoagulation and poor survival. Surgical repair of congenital mitral stenosis must address the multiple levels of obstruction, including resection of the supramitral ring, thinning of leaflets and mobilization of the subvalvular apparatus. Sometimes leaflet augmentation is required. Repair of mitral regurgitation in children may involve simple cleft closures, edge-to-edge repairs, triangular resections and annuloplasties. Techniques used in adults, such as annuloplasty bands or artificial chords, may not be appropriate for children. Overall, an imperfect mitral valve repair may be more acceptable than the negative consequences of a replacement in a child. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  6. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  7. Mitral Valve Prolapse

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ...

  8. Mitral Valve Disease

    Science.gov (United States)

    ... clots, but they also are less durable than mechanical valves and may need to be replaced in the future. Like mitral valve repair, replacement can be done minimally invasively or with traditional open heart surgery. Your medical team will discuss the advantages ...

  9. Transcatheter aortic valve implantation for bicuspid aortic valve stenosis.

    Science.gov (United States)

    Hamdan, Ashraf; Kornowski, Ran

    2015-08-01

    In Preprocedural CT, patients with BAV have larger aortic annulus perimeters, and more calcified valves compared with TAV. In patients with BAV, self-expandable valves were under-expand and balloon-expandable valves have a trend toward increased rates of postimplantation AR grade. Self-expandable valves have higher postprocedural gradient in BAV compared with TAV. © 2015 Wiley Periodicals, Inc.

  10. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  11. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  12. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    OpenAIRE

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mecha...

  13. Internal Acoustics of a Pintle Valve with Supercritical Helium Flow

    Science.gov (United States)

    Fishbach, Sean R.; Davis, R. Benjamin

    2010-01-01

    Large amplitude flow unsteadiness is a common phenomenon within the high flow rate ducts and valves associated with propulsion systems. Boundary layer noise, shear layers and vortex shedding are a few of the many sources of flow oscillations. The presence of lightly damped acoustic modes can organize and amplify these sources of flow perturbation, causing undesirable loading of internal parts. The present study investigates the self-induced acoustic environment within a pintle valve subject to high Reynolds Number flow of helium gas. Experiments were conducted to measure the internal pressure oscillations of the Ares I Launch Abort System (LAS) Attitude Control Motor (ACM) valve. The AGM consists of a solid propellant gas generator with eight pintle valves attached to the aft end. The pintle valve is designed to deliver variable upstream conditions to an attache( converging diverging nozzle. In order to investigate the full range of operating conditions 28 separate tests were conducted with varying pintle position and upstream pressure. Helium gas was utilized in order to closely mimic the speed of sound of the gas generator exhaust, minimizing required scaling during data analysis. The recordec pressure measurements were interrogated to multiple ends. The development of root mean square (RMS) value! versus Reynolds Number and Pintle position are important to creating bounding unsteady load curves for valve internal parts. Spectral analysis was also performed, helping to identify power spectral densities (PSD) of acoustic natural frequencies and boundary layer noise. An interesting and unexpected result was the identification of an acoustic mode within the valve which does not respond until the valve was over 60% open. Further, the response amplitude around this mode can be as large or larger than those associated with lower frequency modes.

  14. Mitral valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... stroke. Valves made from human or animal tissue fail over time. They have an average lifespan of ...

  15. Valve Repair or Replacement

    Science.gov (United States)

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in the ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a side ...

  16. Aortic Valve Regurgitation

    Science.gov (United States)

    ... valves. Rheumatic fever. Rheumatic fever — a complication of strep throat and once a common childhood illness in the ... a severe sore throat, see a doctor. Untreated strep throat can lead to rheumatic fever. Fortunately, strep throat ...

  17. An Experimental Study of Emission and Combustion Characteristics of Marine Diesel Engine in Case of Cylinder Valves Leakage

    Directory of Open Access Journals (Sweden)

    Kowalski Jerzy

    2015-09-01

    Full Text Available Presented paper shows the results of the laboratory tests on the relationship between throttling of both air intake duct and exhaust gas duct and a gaseous emission from the marine engine. The object of research is a laboratory, four-stroke, DI diesel engine, operated at loads from 50 kW to 250 kW at a constant speed equal to 750 rpm. During the laboratory tests over 50 parameters of the engine were measured with its technical condition recognized as a „working properly” and with simulated leakage of both air intake valve and exhaust gas valve on the second cylinder. The results of this laboratory research confirm that the leakage of cylinder valves causes no significant changes of the thermodynamic parameters of the engine. Simulated leakages through the inlet and exhaust valve caused a significant increase in fuel consumption of the engine. Valve leakages cause an increase of the exhaust gas temperature behind the cylinder with leakage and behind other cylinders. The exhaust gas temperature increase is relatively small and clearly visible only at low loads of the engine. The increase of the temperature and pressure of the charging air behind the intercooler were observed too. Charging air temperature is significantly higher during the engine operation with inlet valve leakage. The study results show significant increases of the CO, NOx and CO2 emission for all the mentioned malfunctions. The conclusion is that the results of measurements of the composition of the exhaust gas may contain valuable diagnostic information about the technical condition of the air intake duct and the exhaust gas duct of the marine engine.

  18. ANALYSIS OF EXHAUST GAS EMISSION IN THE MARINE TWO-STROKE SLOW-SPEED DIESEL ENGINE

    Directory of Open Access Journals (Sweden)

    Branko Lalić

    2016-09-01

    Full Text Available This paper explores the problem of exhaust emissions of the marine two-stroke slow-speed diesel engines. After establishing marine diesel engine regulations and defining the parameters influencing exhaust emissions, the simulation model of the marine two-stroke slow-speed diesel engine has been developed. Furthermore, the comparison of numerical and experimentally obtained data has been performed, resulting in achieving the model validity at 100% load, which represents a requirement for further exhaust gas analysis. Deviations obtained at the real engine and the model range from 2% to 7%. An analysis of the influential parameters such as compression ratio, exhaust valve timing and fuel injection timing has been performed. The obtained results have been compared and conclusions have been drawn.

  19. How Is Heart Valve Disease Treated?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  20. How Is Heart Valve Disease Diagnosed?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  1. When a Heart Murmur Signals Valve Disease

    Science.gov (United States)

    ... Order AHA Brochures Your Heart Valve Surgery Your Mitral Valve Prolapse Innocent Heart Murmurs If Your Child Has a Congenital Heart Defect See all of our brochures Valve Disease Resources Patient Guide: Understanding Your Heart Valve Problem | ...

  2. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  3. Aircraft exhaust sulfur emissions

    Energy Technology Data Exchange (ETDEWEB)

    Brown, R.C.; Anderson, M.R.; Miake-Lye, R.C.; Kolb, C.E. [Aerodyne Research, Inc., Billerica, MA (United States). Center for Chemical and Environmental Physics; Sorokin, A.A.; Buriko, Y.I. [Scientific Research Center `Ecolen`, Moscow (Russian Federation)

    1997-12-31

    The extent to which fuel sulfur is converted to SO{sub 3} during combustion and the subsequent turbine flow in supersonic and subsonic aircraft engines is estimated numerically. The analysis is based on: a flamelet model with non-equilibrium sulfur chemistry for the combustor, and a one-dimensional, two-stream model with finite rate chemical kinetics for the turbine. The results indicate that between 2% and 10% of the fuel sulfur is emitted as SO{sub 3}. It is also shown that, for a high fuel sulfur mass loading, conversion in the turbine is limited by the level of atomic oxygen at the combustor exit, leading to higher SO{sub 2} oxidation efficiency at lower fuel sulfur loadings. While SO{sub 2} and SO{sub 3} are the primary oxidation products, the model results further indicate H{sub 2}SO{sub 4} levels on the order of 0.1 ppm for supersonic expansions through a divergent nozzle. This source of fully oxidized S(6) (SO{sub 3} + H{sub 2}SO{sub 4}) exceeds previously calculated S(6) levels due to oxidation of SO{sub 2} by OH in the exhaust plume outside the engine nozzle. (author) 26 refs.

  4. Safety valve for offshore borehole

    Energy Technology Data Exchange (ETDEWEB)

    McGill, H.L.; Randermann, E. Jr.; Musik, O.J.

    1977-10-06

    The invention concerns a new and improved submarine safety valve with a valve element which rotate, which can be used, in emergencies, to separate the wound-up piping which extends into the borehole and to close the production line.

  5. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... diseases of the tricuspid valve are regurgitation and stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid ... the tricuspid valve may also be needed. Tricuspid Stenosis Tricuspid stenosis is a narrowing or blockage of ...

  6. Options for Heart Valve Replacement

    Science.gov (United States)

    ... valve: Aortic regurgitation , (sometimes referred to as aortic insufficiency) is another common valve problem that may require ... allows oxygenated blood to flow backwards into the lungs instead of continuing through the heart as it ...

  7. Echocardiography of the mitral valve

    OpenAIRE

    Omran, A.S.; Arifi, A.A.; Mohamed, A.A.

    2010-01-01

    Mitral valve disease is the second most common valvular heart disease after the aortic valve worldwide. Mitral valve has historically been a structure of interest by pioneers in echocardiography. One of the earliest applications of echocardiography was in the diagnosis of valvular heart disease, particularly mitral stenosis. In this review we wish to take the reader through the structural and hemodynamic evaluation of the normal mitral valve.

  8. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  9. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  10. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...... similar to the one achieved by the expensive and time-consuming CFD calculations. So CFD is only used in case of entirely new designs or where a very detailed knowledge of the flow is required. Even though rules of thumb are useful for those, who have developed them, Danfoss needs an objective and general...

  11. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    resulted from collision or effusion. A static tower has been applied for the main core of this part of the valve which loses balance state under the effect of collision and bounces to the neighboring part, which results in release of the catch and blockage of the gas passing channel.......It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly...

  12. Edwards SAPIEN 3 valve.

    Science.gov (United States)

    Binder, Ronald K; Rodés-Cabau, Josep; Wood, David A; Webb, John G

    2012-09-01

    Building on the established success with the SAPIEN, SAPIEN XT and earlier prototypic transcatheter heart valves (THV) the newest balloon-expandable valve incorporates a number of new and enhanced features intended to reduce the risk of vascular injury, to reduce paravalvular regurgitation, and to facilitate rapid and accurate positioning and implantation. The SAPIEN 3 THV incorporates a cobalt chromium stent, bovine pericardial leaflets, and both an inner and new outer polyethylene terephthalate sealing cuff. The delivery system incorporates an active three-dimensional coaxial positioning catheter, and is compatible with a 14 Fr expandable sheath.

  13. Noncontacting valve-position indicator

    Science.gov (United States)

    Crovella, E. A.; Cummins, R. D.; Wada, J. M.

    1979-01-01

    Position of sealed valve or other movable part is indicated without penetrating housing. Flux from magnets connected to stem of hydraulic valve penetrates pressure wall and is sensed by Hall-effect transducer outside wall. When valve closes, moving stem and magnets, voltage from transducer decreases; thus, stem position is indicated without physical contact.

  14. EHMS: Exhaust Heat Management System

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, T.; Schmidt, M.; Weinbrenner, M.; Geskes, P. [Behr GmbH und Co. KG, Stuttgart (Germany)

    2006-07-01

    Pollutant concentrations in diesel engines are reduced by cooling of the recirculated exhaust. This reduces emissions and particulate matter. The cooler technology can also be used for heating the passenger compartment faster and more economically. The authors present a model ready for seral production, including an exhaust flap for bypass control for use as auxiliary heating system. Further applications in gasoline engines are pointed out. (orig.)

  15. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    Science.gov (United States)

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. Design of Epoxy based Resin Composites for Automotive Applications: A Case Study on IC Engine Valve Guide

    Science.gov (United States)

    Sidhu, J. S.; Lathkar, G. S.; Sharma, S. B.

    2018-01-01

    The present attempt in this project is to reduce the vibrations, temperature due to friction, noise and weight of I C engine valve guide by replacing conventional metal valve guide with composite valve guide. Composite materials have been used in automotive components because of their properties such as low weight, high specific stiffness, corrosion resistance, ability to produce complex shapes, high specific strength and good impact energy absorption etc. The Internal combustion engine valve guides are the parts that support the valves in the cylinder head, besides this it keeps lubricating oil from getting sucked into the combustion chamber past the intake valve stem, it keeps exhaust gases from getting into the crankcase past the exhaust valve stem and it also keeps the valve face in perfect alignment with the valve seat. A valve guide test rig is indigenously fabricated. Valve guides are manufactured using the developed composite material (Resin ARL-136, Hardener AH-126 and 4 vol% WS2), on a CNC lathe. The performance of the developed composite guide under varied conditions of speeds, that is, fixed change in rpm and modulated changes in rpm is assessed. Noise, temperature and vibrations are measured. The experimental data revealed that contribution of composite guide in respect of acceleration, velocity and displacement components of vibration is not substantial. A substantial reduction in noise levels is seen. As far as temperature rise due to friction is concerned maximum components fail at elevated temperatures, with composite guides the temperature generated due to friction at higher speeds is less, a considerable weight reduction is also observed.

  17. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  18. Aortic valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  19. 46 CFR 169.609 - Exhaust systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Exhaust systems. 169.609 Section 169.609 Shipping COAST... Electrical Internal Combustion Engine Installations § 169.609 Exhaust systems. Engine exhaust installations... Yacht Council, Inc. Standard P-1, “Safe Installation of Exhaust Systems for Propulsion and Auxiliary...

  20. 49 CFR 325.91 - Exhaust systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Exhaust systems. 325.91 Section 325.91... EMISSION STANDARDS Exhaust Systems and Tires § 325.91 Exhaust systems. Link to an amendment published at 75 FR 57193, Sept. 20, 2010. A motor vehicle does not conform to the visual exhaust system inspection...

  1. H-CANYON AIR EXHAUST TUNNEL INSPECTION VEHICLE DEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    Minichan, R.; Fogle, R.; Marzolf, A.

    2011-05-24

    The H-Canyon at Savannah River Site is a large concrete structure designed for chemical separation processes of radioactive material. The facility requires a large ventilation system to maintain negative pressure in process areas for radioactive contamination control and personnel protection. The ventilation exhaust is directed through a concrete tunnel under the facility which is approximately five feet wide and 8 feet tall that leads to a sand filter and stack. Acidic vapors in the exhaust have had a degrading effect on the surface of the concrete tunnels. Some areas have been inspected; however, the condition of other areas is unknown. Experience from historical inspections with remote controlled vehicles will be discussed along with the current challenge of inspecting levels below available access points. The area of interest in the exhaust tunnel must be accessed through a 14 X 14 inch concrete plug in the floor of the hot gang valve corridor. The purpose for the inspection is to determine the condition of the inside of the air tunnel and establish if there are any structural concerns. Various landmarks, pipe hangers and exposed rebar are used as reference points for the structural engineers when evaluating the current integrity of the air tunnel.

  2. Measurement of reed valve kinematics

    Directory of Open Access Journals (Sweden)

    Fenkl Michael

    2016-01-01

    Full Text Available The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  3. Innovative safety valve selection techniques and data.

    Science.gov (United States)

    Miller, Curt; Bredemyer, Lindsey

    2007-04-11

    The new valve data resources and modeling tools that are available today are instrumental in verifying that that safety levels are being met in both current installations and project designs. If the new ISA 84 functional safety practices are followed closely, good industry validated data used, and a user's maintenance integrity program strictly enforced, plants should feel confident that their design has been quantitatively reinforced. After 2 years of exhaustive reliability studies, there are now techniques and data available to support this safety system component deficiency. Everyone who has gone through the process of safety integrity level (SIL) verification (i.e. reliability math) will appreciate the progress made in this area. The benefits of these advancements are improved safety with lower lifecycle costs such as lower capital investment and/or longer testing intervals. This discussion will start with a review of the different valve, actuator, and solenoid/positioner combinations that can be used and their associated application restraints. Failure rate reliability studies (i.e. FMEDA) and data associated with the final combinations will then discussed. Finally, the impact of the selections on each safety system's SIL verification will be reviewed.

  4. Micro-valve pump light valve display

    Science.gov (United States)

    Lee, Yee-Chun

    1993-01-01

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  5. Motor Vehicle Exhaust Gas Suicide.

    Science.gov (United States)

    Routley, Virginia

    2007-01-01

    In many motorized countries, inhalation of carbon monoxide from motor vehicle exhaust gas (MVEG) has been one of the leading methods of suicide. In some countries it remains so (e.g., Australia 16.0% of suicides in 2005). Relative to other methods it is a planned method and one often used by middle-aged males. The study provides a review of countermeasures aimed at restricting this method of suicide. The prevention measures identified were catalytic converters (introduced to reduce carbon monoxide for environmental reasons); in-cabin sensors; exhaust pipe modification; automatic idling stops; and helpline signage at suicide "hotspots." Catalytic converters are now in 90% of new vehicles worldwide and literature supports them being associated with a reduction in exhaust-gassing suicides. There remain, however, accounts of exhaust-gas fatalities in modern vehicles, whether accidentally or by suicide. These deaths and also crashes from fatigue could potentially be prevented by in-cabin multi-gas sensors, these having been developed to the prototype stage. Helpline signage at an exhaust-gassing suicide "hotspot" had some success in reducing suicides. The evidence on method substitution and whether a reduction in MVEG suicides causes a reduction in total suicides is inconsistent.

  6. The Vietnamese pig as a translational animal model to evaluate tissue engineered heart valves: promising early experience.

    Science.gov (United States)

    Gallo, Michele; Poser, Helen; Bottio, Tommaso; Bonetti, Antonella; Franci, Paolo; Naso, Filippo; Buratto, Edward; Zanella, Fabio; Perona, Giovanni; Dal Lin, Carlo; Bianco, Roberto; Spina, Michele; Busetto, Roberto; Marchini, Maurizio; Ortolani, Fulvia; Iop, Laura; Gerosa, Gino

    2017-05-09

    Several animal models are currently used for the surgical implantation of either biologic or biopolymeric scaffolds in order to provide in vivo assessment of tissue-engineered heart valves. The Vietnamese pig (VP) is herein proposed as a suitable recipient to test the function of novel bioengineered valve substitutes, in the reconstruction of the right ventricular outflow tract (RVOT). This review aims to provide a complete and exhaustive panel of physiological parameters and methodological information for preclinical studies of tissue-engineered heart valves in the VP animal model.

  7. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  8. First Reported Successful Femoral Valve-in-Valve Transcatheter Aortic Valve Replacement Using the Edwards Sapien 3 Valve.

    Science.gov (United States)

    Fournier, Stephane; Monney, Pierre; Roguelov, Christan; Zuffi, Andrea; Iglesias, Juan F; Qanadli, Salah D; Courbon, Cecile; Eeckhout, Eric; Muller, Olivier

    2015-10-01

    Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.

  9. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-02-01

    Full Text Available Aim: Valve diseases in developing countries like Turkey which often occur as a complication of rheumatic fever are a serious disease. Surgical treatment of valve diseases should be done before irreversible damage to the myocardium occurred. In this study, we aimed to present the early results of mechanical valve replacement operations. Method: A hundred patients with mechanical valve replacement surgery were retrospectively evaluated in Seyhan Application Center attached to our clinic between July 2007 and August 2011. Results: Fifty patients were male and 50 were women. The mean age of patients was 47.88 (18-78. Isolated aortic valve replacement (AVR was performed to 23 patients, isolated mitral valve replacement (MVR was 32, double valve replacement (AVR + MVR was 12, MVR + aortic valve valvuloplasty was 1, AVR + mitral kommissurotomi was 1, AVR + coronary artery bypass graft surgery (CABG was 17, MVR + CABG was 8, MVR + atrial septal defect closure was 2 and Bentall procedure.was 4 patients. In addition, ablation procedure was performed to 5 patients intraoperatively because of preoperative atrial fibrillation. Two patients (2 % died in early postoperative period. Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1.000: 49-54

  10. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  11. Performance Characteristics of an Isothermal Freeze Valve

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  12. Tricuspid Valve Replacement, Mechnical vs. Biological Valve, Which Is Better?

    Directory of Open Access Journals (Sweden)

    Haitham Akram Altaani

    2013-06-01

    Full Text Available Background: The initial trial in tricuspid surgery is repair; however, replacement is done whenever the valve is badly diseased. Tricuspid valve replacement comprises 1.7% of all tricuspid valve surgeries. Materials and Methods: The present retrospective study was performed using the medical records of 21 cases who underwent tricuspid valve replacement from January 2002 until the end of December 2010. The mean age of the participants was 52.3±8.8 years and 66.7% were females. In addition, tricuspid valve replacement was associated with mitral valve surgery, aortic valve surgery, and both in 14.3%, 4.8%, and 33.3% of the cases, respectively. Yet, isolated tricuspid valve replacement and redo surgery were performed in 10 cases (47.6% and 8 cases (38.1%, respectively. Besides, trial of repair was done in 14 cases (66.7%. Moreover, biological and mechanical valves were used in 76.2% and 23.8% of the patients, respectively. Results: According to the results, early mortality was 23.8% and one year survival was 66.7%. Moreover, early mortality was caused by right ventricular failure, multiorgan failure, medistinitis, and intracerbral bleeding in 42%, 28.6%, 14.3%, and 14.3% of the cases, respectively. In addition, 57.1% of the deaths had occurred in the cases where the biological valve was used, while 42.9% of the deaths had taken place where the mechanical one was utilized. Conclusions: The patients who require tricuspid valve replacement are usually high risk surgical candidates with early and long term mortality. The findings of the current study showed no significant hemodynamic difference between mechanical and biological valves.

  13. Thermo-electric valve

    Science.gov (United States)

    Chamberland, R. R.; Stanland, A. J.

    1985-02-01

    A thermo-electric valve is described for scuttling floating devices comprising, a cylindrical sleeve affixed to and passing through a bulkhead separating a pressurized medium on one side from a lower pressure space on the other side, a piston moveably mounted within the sleeve bore and exposed to the pressurized medium having a portion thereof blocking the sleeve bore, an O-ring sealing the gap between the piston head and the sleeve bore, a fully compressed spring pressing against the piston, a rigid dielectric washer and a low power resistor holding the piston against the spring. In operation a low current is passed through the resistor, disintegrating it and releasing the spring's stored energy. This actuates the valve by expelling the piston which allows the pressurized fluid or gas to enter the lower pressure space.

  14. Patents and heart valve surgery--I: mechanical valves.

    Science.gov (United States)

    Cheema, Faisal H; Hussain, Nasir; Kossar, Alexander P; Polvani, Gianluca

    2013-04-01

    Valvular heart disease, inherited or acquired, affects more than 5 million Americans yearly. Whereas medical treatment is beneficial in the initial stages of valvular heart disease, surgical correction provides symptomatic relief and long-term survival benefits. Surgical options include either repair or replacement using mechanical or bio-prosthetic valves. Patient age and the post-operative need for anticoagulation therapy are major determinants of the choice between use of mechanical or bio-prosthetic valves. Since the first mechanical valves were made available several decades ago, the incorporation of increasingly sophisticated materials and methodologies has led to substantial improvements in the valve design, and has catalyzed a parallel increase in the amount of patents issued for these emerging technologies. In this paper, we have chronologically reviewed such patents, briefly discussed various challenges that mechanical heart valve implementation is faced with and finally reviewed some of the strategies employed to overcome such obstacles. An ideal prosthetic heart valve would comprehensively mimic the natural hemodynamics and physiology of the native heart valve. Additionally, such a valve would be easily implantable, associated with a minimal risk of thrombosis and thus need for anti-coagulation, and with a proven long-term durability. With cutting edge technological advancements in the recent times, the ongoing innovative and collaborative efforts of physicians, scientists, and engineers will not seize until an ideal mechanical heart valve becomes a reality.

  15. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early...... and southern European countries. Imbalances in the prevalence of rheumatic heart disease, health resource availability and variations in surgical practice throughout Europe might be possible etiological causes....

  16. Semiconductor industry wafer fab exhaust management

    CERN Document Server

    Sherer, Michael J

    2005-01-01

    Given the myriad exhaust compounds and the corresponding problems that they can pose in an exhaust management system, the proper choice of such systems is a complex task. Presenting the fundamentals, technical details, and general solutions to real-world problems, Semiconductor Industry: Wafer Fab Exhaust Management offers practical guidance on selecting an appropriate system for a given application. Using examples that provide a clear understanding of the concepts discussed, Sherer covers facility layout, support facilities operations, and semiconductor process equipment, followed by exhaust types and challenges. He reviews exhaust point-of-use devices and exhaust line requirements needed between process equipment and the centralized exhaust system. The book includes information on wet scrubbers for a centralized acid exhaust system and a centralized ammonia exhaust system and on centralized equipment to control volatile organic compounds. It concludes with a chapter devoted to emergency releases and a separ...

  17. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  18. Optothermally actuated capillary burst valve

    Science.gov (United States)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders; Marie, Rodolphe

    2017-04-01

    We demonstrate the optothermal actuation of individual capillary burst valves in an all-polymer microfluidic device. The capillary burst valves are realised in a planar design by introducing a fluidic constriction in a microfluidic channel of constant depth. We show that a capillary burst valve can be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett. 10, 826-832 (2010)]. An individual valve is burst by focusing the laser in its vicinity. We demonstrate the capture of single polystyrene 7 μm beads in the constriction triggered by the bursting of the valve.

  19. Update of transcatheter valve treatment.

    Science.gov (United States)

    Liu, Xian-bao; Wang, Jian-an

    2013-08-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair--MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed.

  20. Investigation of a rotary valving system with variable valve timing for internal combustion engines: Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Cross, P.C.; Hansen, C.N.

    1994-11-18

    The objective of the program was to provide a functional demonstration of the Hansen Rotary Valving System with Variable Valve timing (HRVS/VVT), capable of throttleless inlet charge control, as an alternative to conventional poppet-valves for use in spark ignited internal combustion engines. The goal of this new technology is to secure benefits in fuel economy, broadened torque band, vibration reduction, and overhaul accessibility. Additionally, use of the variable valve timing capability to vary the effective compression ratio is expected to improve multi-fuel tolerance and efficiency. Efforts directed at the design of HRVS components proved to be far more extensive than had been anticipated, ultimately requiring that proof-trial design/development work be performed. Although both time and funds were exhausted before optical or ion-probe types of in-cylinder investigation could be undertaken, a great deal of laboratory data was acquired during the course of the design/development work. This laboratory data is the basis for the information presented in this Final Report.

  1. Mitral valve repair versus replacement

    Science.gov (United States)

    Keshavamurthy, Suresh; Gillinov, A. Marc

    2015-01-01

    Degenerative, ischemic, rheumatic and infectious (endocarditis) processes are responsible for mitral valve disease in adults. Mitral valve repair has been widely regarded as the optimal surgical procedure to treat mitral valve dysfunction of all etiologies. The supporting evidence for repair over replacement is strongest in degenerative mitral regurgitation. The aim of the present review is to summarize the data in each category of mitral insufficiency and to provide recommendations based upon this data. PMID:26309824

  2. Exhaust Gas Scrubber Washwater Effluent

    Science.gov (United States)

    2011-11-01

    10 Sulfur Content of Certain Liquid Fuels Exhaust Gas Scrubber Washwater Effluent...diesel and gasoline components DIN Dissolved inorganic nitrogen THC Total hydrocarbon TKN Total Kjeldahl nitrogen HEM Hexane extractable...Benefit Analysis to support the impact assessment accompanying the revision of Directive 1999/32/EC on the sulfur content of certain liquid fuels

  3. Ship exhaust gas plume cooling

    NARCIS (Netherlands)

    Schleijpen, H.M.A.; Neele, P.P.

    2004-01-01

    The exhaust gas plume is an important and sometimes dominating contributor to the infrared signature of ships. Suppression of the infrared ship signatures has been studied by TNO for the Royal Netherlands Navy over considerable time. This study deals with the suppression effects, which can be

  4. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  5. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural...

  6. In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves.

    Science.gov (United States)

    Simonato, Matheus; Azadani, Ali N; Webb, John; Leipsic, Jonathon; Kornowski, Ran; Vahanian, Alec; Wood, David; Piazza, Nicolo; Kodali, Susheel; Ye, Jian; Whisenant, Brian; Gaia, Diego; Aziz, Mina; Pasala, Tilak; Mehilli, Julinda; Wijeysundera, Harindra C; Tchetche, Didier; Moat, Neil; Teles, Rui; Petronio, Anna Sonia; Hildick-Smith, David; Landes, Uri; Windecker, Stephan; Arbel, Yaron; Mendiz, Oscar; Makkar, Raj; Tseng, Elaine; Dvir, Danny

    2016-09-18

    Transcatheter heart valve (THV) implantation in failed bioprosthetic valves (valve-in-valve [ViV]) offers an alternative therapy for high-risk patients. Elevated post-procedural gradients are a significant limitation of aortic ViV. Our objective was to assess the relationship between depth of implantation and haemodynamics. Commercially available THVs used for ViV were included in the analysis (CoreValve Evolut, SAPIEN XT and the Portico valve). THVs were implanted in small surgical valves (label size 19 mm) to simulate boundary conditions. Custom-mounted pulse duplicators registered relevant haemodynamic parameters. Twenty-eight experiments were performed (13 CVE, 5 SXT and 10 Portico). Ranges of depth of implantation were: CVE: -1.2 mm to 15.7 mm; SXT: -2.2 mm to 7.5 mm; Portico: 1.4 mm to 12.1 mm. Polynomial regression established a relationship between depth of implantation and valvular mean gradients (CVE: p<0.001; SXT: p=0.01; Portico: p=0.002), as well as with EOA (CVE: p<0.001; SXT: p=0.02; Portico valve: p=0.003). In addition, leaflet coaptation was better in the high implantation experiments for all valves. The current comprehensive bench testing assessment demonstrates the importance of high device position for the attainment of optimal haemodynamics during aortic ViV procedures.

  7. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  8. Exhaust System Reinforced by Jet Flow

    DEFF Research Database (Denmark)

    Pedersen, Lars Germann; Nielsen, Peter V.

    Since 1985 the University of Aalborg and Nordfab A/S have been working on an exhaust principle which is quite different from traditional exhaust systems. The REEXS principle (Reinforced Exhaust System), which originally was designed for the agricultural sector, is particularly well......-suited for industrial ventilation purposes. With the REEXS principle it is possible to create a flow pattern in front of the exhaust opening which will have a considerable influence on the general flow in a given room....

  9. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...

  10. Butterfly valve apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Ball, L.K.; Hines, M.U.; Miller, T.L.

    1990-10-23

    This patent describes a method of controlling fluid flow in a duct, and duct having a wall bounding a flow path wherein flows the fluid. It comprises: disposing a plate-like valve member in the flow path, which valve member is pivotally movable about an axis generally transverse to the duct between a first position transverse to and closing the flow path and a second position generally parallel with the flow path to open and allow fluid flow therein: transecting the valve member with the pivot axis to define with respect to direction of the fluid flow in the duct and pivotal movement of the valve member toward the open position an upstream valve member wing and a downstream valve member wing each substantially equal in area: increasing the effective area of the valve member upon which the fluid flow exerts fluid dynamic flow forces; and pivoting the valve member toward the second open position thereof in response to the increase of effective area.

  11. The spin-valve transistor

    NARCIS (Netherlands)

    Anil Kumar, P.S.; Lodder, J.C.

    2000-01-01

    The spin-valve transistor is a magnetoelectronic device that can be used as a magnetic field sensor. It has a ferromagnet-semiconductor hybrid structure. Using a vacuum metal bonding technique, the spin-valve transistor structure Si/Pt/NiFe/Au/Co/Au/Si is obtained. It employs hot electron transport

  12. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-03-01

    Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1: 49-54

  13. Electrophysiologic Study of Exhaustive Exercise

    Directory of Open Access Journals (Sweden)

    MA Babaee Bigi

    2010-12-01

    Full Text Available Background: Exhaustive exercise is well known to pose a variety ofhealth hazards, such as sudden cardiac death reported in ultra-marathon runners.Depressed parasympathetic tone is associated with increased risk of suddencardiac death, thus parasympathetic withdrawal in post-exercise phase may be ahigh risk period for sudden death. To date, the effect on cardiacelectrophysiology after exhaustive strenuous exercise has not been described.The aim of this study was to evaluate the impact of severe exhaustive exerciseon cardiac electrophysiology.Methods: The subjects in ranger training were invited to participatein this prospective study. The parameters measured consisted of PR interval, QRSduration, and macro T wave alternans as well as corrected QT, QTc dispersion,Tpeak –Tend interval and Tpeak –Tend dispersion.Results: The study group consisted of 40 consecutive male rangers whocompleted training and the control group (22 healthy age and height matched malesubjects. In regard to electrocardiographic criteria, no differences were foundbetween rangers before and after training program. In respect of therepolarization markers, there were no significant differences between therangers before and after training program.

  14. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    Science.gov (United States)

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  16. 20 CFR 636.5 - Exhaustion of grantee level procedure.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Exhaustion of grantee level procedure. 636.5..., INVESTIGATIONS AND HEARINGS § 636.5 Exhaustion of grantee level procedure. (a) Exhaustion required. No... have been exhausted. (b) Exhaustion exceptions. Complainants who have not exhausted the procedures at...

  17. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  18. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  19. Management of a locked Strata valve.

    Science.gov (United States)

    Bullivant, Kelly J; Mitha, Alim P; Hamilton, Mark G

    2009-04-01

    The PS Medical Strata valve is a programmable shunt valve used in the treatment of hydrocephalus that allows for noninvasive changes in the pressure setting using a magnet. The Strata valve is sensitive to magnetic fields, and reprogramming is frequently necessary after MR imaging. A known but rare complication of the Strata valve is that the rotor can become locked, causing shunt malfunction. This complication can only occur in a first generation Strata valve.

  20. 3D Printed Multimaterial Microfluidic Valve

    OpenAIRE

    Keating, Steven J.; Gariboldi, Maria Isabella; Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deform...

  1. Treatment of Aortic, Mitral and Tricuspid Structural Bioprosthetic Valve Deterioration Using the Valve-in-Valve Technique.

    Science.gov (United States)

    Codner, Pablo; Assali, Abid; Vaknin-Assa, Hana; Shapira, Yaron; Orvin, Katia; Sharony, Ram; Sagie, Alexander; Kornowski, Ran

    2015-05-01

    The percutaneous approach for a failed bioprosthetic valve is an emerging alternative to redo-valve surgery in patients at high surgical risk. The study aim was to describe the treatment of patients with structural bioprosthetic valve deterioration, using the valve-in-valve technique. A total of 33 consecutive patients with symptomatic structural bioprosthetic valve deterioration was treated at the authors' institution, using the valve-in-valve technique. The valve-in-valve procedure in the aortic position was performed in 23 patients (mean age 81.4 ± 5.9 years; mean STS score 9.6 ± 5.4). The self-expandable and balloon-expandable devices were used in 21 cases (91.3%) and two cases (8.7%), respectively. Procedures were performed via the trans-femoral, trans-axillary and trans-apical routes in 18 (78.2%), three (13%) and two (8.7%) cases, respectively. After the procedure, all patients were in NYHA class I/II. Survival rates were 95.6% at the one-year follow up. The valve-in-valve procedure in the mitral position was performed in 10 patients (mean age 73.6 ± 15 years; mean STS score 7.7 ± 4.1). All procedures were performed using the balloon-expandable device via the trans-apical route. The composite end point of device success was achieved in all patients. Survival rates were 100% and 75% at one month and two years' follow up, respectively. A single valve-in-valve implantation within a failed tricuspid bioprosthetic valve was also successfully performed. In the authors' experience, the valve-in-valve technique for the treatment of a wide range of bioprosthetic valve deterioration modes of failure in different valve positions is safe and very effective.

  2. T Cell Exhaustion During Persistent Viral Infections

    Science.gov (United States)

    Kahan, Shannon M.; Wherry, E. John; Zajac, Allan J.

    2015-01-01

    Although robust and highly effective anti-viral T cells contribute to the clearance of many acute infections, viral persistence is associated with the development of functionally inferior, exhausted, T cell responses. Exhaustion develops in a step-wise and progressive manner, ranges in severity, and can culminate in the deletion of the anti-viral T cells. This disarming of the response is consequential as it compromises viral control and potentially serves to dampen immune-mediated damage. Exhausted T cells are unable to elaborate typical anti-viral effector functions. They are characterized by the sustained upregulation of inhibitory receptors and display a gene expression profile that distinguishes them from prototypic effector and memory T cell populations. In this review we discuss the properties of exhausted T cells; the virological and immunological conditions that favor their development; the cellular and molecular signals that sustain the exhausted state; and strategies for preventing and reversing exhaustion to favor viral control. PMID:25620767

  3. Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

    Science.gov (United States)

    Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.

    2015-01-01

    It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since

  4. Desulphurization of exhaust gases in chemical processes

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, K.; Wischnewski, W.

    1981-01-01

    The sulfur content of exhaust gases can be reduced by: desulphurization of fuels; modification of processes; or treatment of resultant gases. In this paper a few selected examples from the chemical industry in the German Democratic Republic are presented. Using modified processes and treating the resultant gases, the sulphuric content of exhaust gases is effectively reduced. Methods to reduce the sulfur content of exhaust gases are described in the field of production of: sulphuric acid; viscose; fertilizers; and paraffin.

  5. Emotionally exhausting factors in general practitioners? work

    OpenAIRE

    Torppa, M.A.; Kuikka, L.; Nevalainen, M.; Pitk?l?, K.H.

    2015-01-01

    Background. Emotional exhaustion is central in burnout syndrome and signals its development. General practitioners? (GP) work is emotionally challenging but research on these aspects is lacking. Objective. To study the prevalence of emotional exhaustion among GPs and to evaluate how their characteristics and work experiences are associated with emotional exhaustion. Design and methods. A questionnaire survey was carried out among GPs in Finland in 2011 in which questions were posed regarding ...

  6. Transcatheter Replacement of Failed Bioprosthetic Valves

    DEFF Research Database (Denmark)

    Simonato, Matheus; Webb, John; Kornowski, Ran

    2016-01-01

    valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). Conclusions-High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self-and balloon-expandable transcatheter......Background-Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets...... for implantation that would improve hemodynamics after ViV. Methods and Results-Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated...

  7. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  8. Software for computer-aided study of intake and exhaust systems for engines

    Energy Technology Data Exchange (ETDEWEB)

    Payri, F.; Benajes, J.; Chust, M.D. (Universidad Politecnica de Valencia (ES))

    1991-01-01

    In this work are described the main characteristics of a software designed to globally analyze the behavior of intake and exhaust systems of alternating engines with multiple cylinders and the effect produced by each element on the engine performances and the emitted noise. The software consists in a model of waves action, which computes the fluid behavior through the collectors using particular boundary conditions for each singular element of the system: filter, compressor, carburettor, valves, pipes, mufflers, junctions, etc. Moreover, the software contains interactive modules to introduce the data and to graphically output the results. Finally we present results showing the model accuracy and examples of input and outputs. 29 refs..

  9. T cell exhaustion and immune-mediated disease-the potential for therapeutic exhaustion.

    Science.gov (United States)

    McKinney, Eoin F; Smith, Kenneth Gc

    2016-12-01

    T cell exhaustion represents a continuous spectrum of cellular dysfunction induced during chronic viral infection, facilitating viral persistence and associating with poor clinical outcome. Modulation of T cell exhaustion can restore function in exhausted CD8 T cells, promoting viral clearance. Exhaustion has also been implicated as playing an important role in anti-tumour responses, whereby exhausted tumour-infiltrating lymphocytes fail to control tumour progression. More recently exhaustion has been linked to long-term clinical outcome in multiple autoimmune diseases but, in contrast to cancer or infection, it is associated with a favourable clinical outcome characterised by fewer relapses. An increasing understanding of key inhibitory signals promoting exhaustion has led to advances in therapy for chronic infection and cancer. An increasing understanding of this biology may facilitate novel treatment approaches for autoimmunity through the therapeutic induction of exhaustion. Copyright © 2016. Published by Elsevier Ltd.

  10. Sutureless Valves Reduce Hospital Costs Compared to Traditional Valves.

    Science.gov (United States)

    Laborde, François; Folliguet, Thierry; Ghorayeb, Gabriel; Zannis, Konstantinos

    2017-01-01

    The study aim was to assess differences in clinical outcome, safety, and associated costs between sutureless and aortic isolated aortic valve replacement (AVR) with a standard bioprosthesis. A retrospective comparative study was conducted to investigate 65 patients, each of whom had undergone isolated AVR with a traditional aortic valve (T) or a Perceval S sutureless aortic prosthesis (P) between January 2010 and December 2012. Cost data were drawn from the proprietary cost accounting system of the hospital, excluding acquisition costs of the devices. A linear regression model was used to estimate the mean total costs difference between groups. The mean cardiopulmonary bypass time and aortic cross-clamp times in the T and P groups were 80 ± 41 min and 58 ± 26 min versus 38 ± 16 min and 26 ± 10 min, respectively (p costs savings for group P compared to group T were €3,801 (p = 0.13), mainly driven by hospital stay costs. Savings between the P and T groups increased with age: €4,992 in patients aged 70-79 years and €9,326 in those aged 80+ years, and with risk (€4,296 for high-risk patients). Sutureless aortic valves present shorter procedural times and lower hospital costs compared to traditional valves, with higher cost savings at increased patient age and risk. Sutureless aortic valves seem to be cost-effective in patients undergoing AVR.

  11. Robotically assisted mitral valve replacement.

    Science.gov (United States)

    Gao, Changqing; Yang, Ming; Xiao, Cangsong; Wang, Gang; Wu, Yang; Wang, Jiali; Li, Jiachun

    2012-04-01

    In the present study, we determined the safety and efficacy of robotic mitral valve replacement using robotic technology. From January 2007 through March 2011, more than 400 patients underwent various types of robotic cardiac surgery in our department. Of these, 22 consecutive patients underwent robotically assisted mitral valve replacement. Of the 22 patients with isolated rheumatic mitral valve stenosis (9 men and 13 women), the mean age was 44.7 ± 19.8 years (range, 32-65). Preoperatively, all patients underwent a complete workup, including coronary angiography and transthoracic echocardiography. Of the 22 patients, 15 had concomitant atrial fibrillation. The surgical approach was through 4 right-side chest ports with femoral perfusion. Aortic occlusion was performed with a Chitwood crossclamp, and antegrade cardioplegia was administered directly by way of the anterior chest. Using 3 port incisions in the right side of the chest and a 2.5- to 3.0-cm working port, all the procedures were completed with the da Vinci S robot. All patients underwent successful robotic surgery. Of the 22 patients, 16 received a mechanical valve and 6 a tissue valve. The mean cardiopulmonary bypass time and aortic crossclamp time was 137.1 ± 21.9 minutes (range, 105-168) and 99.3 ± 17.9 minutes (range, 80-133), respectively. No operative deaths, stroke, or other complications occurred, and no incisional conversions were required. After surgery, all the patients were followed up echocardiographically. Robotically assisted mitral valve replacement can be performed safely in patients with isolated mitral valve stenosis, and surgical results are excellent. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  12. What Are the Signs and Symptoms of Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  13. On-board diagnostics of fully variable valve actuator systems in spark-ignited combustion engines

    Energy Technology Data Exchange (ETDEWEB)

    Sarac, Ipek

    2010-07-01

    Variable valve actuation (VVA) is being employed in contemporary engines to improve fuel consumption, torque characteristics and emissions of combustion engines by enabling the realization of different combustion strategies. Fully variable valve actuation (FVVA) makes it possible to apply a wider range of strategies (e.g., homogenous charge compression ignition (HCCI), dethrottling, internal residual gas mechanism, 2/4 Stroke Switching). With FVVA, the gas exchange valves can be actuated at arbitrary points in time, with separate variable lifting for the intake and exhaust valves of each cylinder. Making FVVA systems ready for the market requires to provide the system with appropriate fault-diagnostic functionality. Additional degrees of freedom of FVVA systems introduce different fault cases which have to be considered in terms of their emission relevance within the scope of diagnostics standards such as On-Board Diagnosis II (OBD II). The faults and their effects on emissions have not been analyzed by any other study, yet. To fill this gab, here the possible faults are generated using a four-cylinder gasoline camless test bench engine. Measurements are carried out using different strategies at low loads, namely dethrottling with early intake valve closing and combining high internal residual gas with dethrottling. Each fault case is thoroughly analyzed, and the emission-relevant faults are pointed out for initial consideration. A trivial approach to diagnose fully variable valve actuators is to introduce position sensors for each actuator to track the valve lift curve. However, this approach increases the cost of the system undesirably. Thus, here alternative methods are explored such as indirect use of common powertrain sensors. Considering that active diagnosis may lead to suboptimal engine control schemes, the possibilities of fault detection and isolation are investigated without relying on active diagnosis. Air path sensors are affected foremost by any

  14. Butterfly valve of all rubber lining type

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Shosaku; Nakatsuma, Sumiya (Kubota Ltd., Osaka (Japan)); Sasaki, Iwao; Aoki, Naoshi

    1982-08-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported.

  15. Mitral valve aneurysm associated with aortic valve endocarditis and regurgitation.

    Science.gov (United States)

    Raval, Amish N; Menkis, Alan H; Boughner, Derek R

    2002-01-01

    Mitral valve aneurysms are rare complications occurring most commonly in association with aortic valve infective endocarditis. [Decroly 1989, Chua 1990, Northridge 1991, Karalis 1992, Roguin 1996, Mollod 1997, Vilacosta 1997, Cai 1999, Vilacosta 1999, Teskey 1999, Chan 2000, Goh 2000, Marcos- Alberca 2000] While the mechanism of the development of this lesion is unclear, complications such as perforation can occur and lead to significant mitral regurgitation. [Decroly 1989, Karalis 1992, Teskey 1999, Vilacosta 1999]; The case of a 69-year-old male with Streptococcus Sanguis aortic valve endocarditis and associated anterior mitral leaflet aneurysm is presented. Following surgery, tissue pathology of the excised lesion revealed myxomatous degeneration and no active endocarditis or inflammatory cells. This may add support to the hypothesis that physical stress due to severe aortic insufficiency and structural weakening, without infection of the anterior mitral leaflet, can lead to the development of this lesion.

  16. Valved stent for off-pump mitral valve replacement

    OpenAIRE

    Ma, L.(School of Physics, Shandong University, Shandong, China)

    2004-01-01

    Résumé Objectif : Evaluer un remplacement de valve mitrale hors-pompe avec des stents valvés Méthode: Des homografts préservés dans du glutaraldehyde ont été suturés dans une prothèse tubulaire avant d'être soudés à deux stents Z en nitinol pour créer deux couronnes auto- extensibles. A) Nous avons testé la valve in vitro en utilisant un circuit pulsatile fermé (mock loop) ayant de débuter les expériences sur les porcs. (n=8, 46 .0± 4.3 kg : B). L'oreillette gauche a été exposée p...

  17. Local Exhaust Optimization and Worker Exposure

    DEFF Research Database (Denmark)

    Heiselberg, Per; Pedersen, Morten; Plath, Thomas

    This paper describes a process of optimisation of exhaust efficiency and of minimisation of worker exposure at a semiautomatic printing machine at a printing office.......This paper describes a process of optimisation of exhaust efficiency and of minimisation of worker exposure at a semiautomatic printing machine at a printing office....

  18. Vital exhaustion and risk for cancer

    DEFF Research Database (Denmark)

    Bergelt, Corinna; Christensen, Jane Hvarregaard; Prescott, Eva

    2005-01-01

    Vital exhaustion, defined as feelings of depression and fatigue, has previously been investigated mainly as a risk factor for cardiovascular disease. The authors investigated the association between depressive feelings and fatigue as covered by the concept of vital exhaustion and the risk...

  19. 49 CFR 393.83 - Exhaust systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Exhaust systems. 393.83 Section 393.83... NECESSARY FOR SAFE OPERATION Miscellaneous Parts and Accessories § 393.83 Exhaust systems. (a) Every motor... shall have a system to direct the discharge of such fumes. No part shall be located where its location...

  20. Effect of exhaustive exercise on myocardial performance.

    Science.gov (United States)

    Grimditch, G K; Barnard, R J; Duncan, H W

    1981-11-01

    Several investigators have reported ultrastructural changes in hearts of animals exercised to exhaustion. The present study was designed to determine whether functional changes occur in the intact heart at exhaustion. Adult mongrel dogs (n = 8) were chronically instrumented to measure cardiac output, coronary blood flow, aortic blood pressure, left ventricular pressure, +dP/dtmax, and -dP/dtmax. After recovery, the dogs were run to exhaustion at a constant work load, eliciting approximately 70% of maximum heart rate. The exhaustive bouts were terminated when the animals either refused or were unable to continue running, at which time their rectal temperatures approaches 42.2 degree C. The mean exhaustion time was 76.7 +/- 11.8 min. All parameters increased from rest to steady state with the exception of stroke volume (23.2 +/- 4.9 vs. 20.5 +/- 1.6 ml), which remained constant. In the transition from steady state to exhaustion, only +dP/dtmax (6,652 +/- 291 vs. 7,689 +/- 479 Torr/s) and -dP/dtmax (4,110 +/- 227 vs. 4,890 +/- 215 Torr/s) increased significantly; all other values exhibited no significant change. Similarly, when maximum cardiovascular parameters were measured before and after exhaustion, no significant changes were found. These data show that cardiac contractile function is not depressed in dogs as a result of exhaustive exercise.

  1. Analysis of the Scavenging Process of a Two-Stroke Free-Piston Engine Based on the Selection of Scavenging Ports or Valves

    Directory of Open Access Journals (Sweden)

    Boru Jia

    2018-02-01

    Full Text Available The free-piston engine generator (FPEG is a linear energy conversion device with the objective of utilisation within a hybrid-electric automotive vehicle power system. In this research, the piston dynamic characteristics of an FPEG is compared with that of a conventional engine (CE of the same size, and the difference in the valve timing is compared for both port scavenging type and valve scavenging type, with the exhaust valve closing timing is selected as the parameter. A zero-dimensional simulation model is developed in Ricardo WAVE software (2016.1, with the piston dynamics obtained from the simulation model in Matlab/SIMULINK (R2017a. For the CE and FEPG using scavenging ports, in order to improve its power output to the same level as that of a CE, the inlet gas pressure is suggested to be improved to above 1.2 bar, approximately 0.2 bar higher than that used for a CE. If a CE cylinder with exhaust valves is adopted or referred to during the development of an FPEG prototype, the exhaust valve is suggested to be closed earlier to improve its power output, and a higher intake pressure is also suggested if its output power is expected to be the same or higher than that of a CE.

  2. Mechanical heart valve cavitation in patients with bileaflet valves.

    Science.gov (United States)

    Johansen, Peter; Andersen, Tina S; Hasenkam, J Michael; Nygaard, Hans; Paulsen, Peter K

    2014-01-01

    Today, the quality of mechanical heart valves is quite high, and implantation has become a routine clinical procedure with a low operative mortality (mechanism found to be a possible contributor to these adverse effects is cavitation. In vitro, cavitation has been directly demonstrated by visualization and indirectly in vivo by registering of high frequency pressure fluctuations (HFPF). Tilting disc valves are thought of having higher cavitation potential than bileaflet valves due to higher closing velocities. However, the thromboembolic potential seems to be the same. Further studies are therefore needed to investigate the cavitation potential of bileaflet valves in vivo. The post processing of HFPF have shown difficulties when applied on bileaflet vavles due to asynchronous closure of the two leaflets. The aim of this study was therefore to isolate the pressure signature from each leaflet closure and perform cavitation analyses on each component. Six patients were included in the study (St. Jude Medical (n=3) and CarboMedics (n=3); all aortic bileaflet mechanical heart valves). HFPFs were recorded intraoperatively through a hydrophone at the aortic root. The pressure signature relating to the first and second leaflet closure was isolated and cavitation parameters were calculated (RMS after 50 kHz highpass filtering and signal energy). Data were averaged over 30 heart cycles. For all patients both the RMS value and signal energy of the second leaflet closure were higher than for the first leaflet closure. This indicates that the second leaflet closure is most prone to cause cavitation. Therefore, quantifying cavitation based on the HFPF related to the second leaflet closure may suggest that the cavitation potential for bileaflet valves in vivo may be higher than previous studies have suggested.

  3. Minimally Invasive Heart Valve Surgery.

    Science.gov (United States)

    Bouhout, Ismail; Morgant, Marie-Catherine; Bouchard, Denis

    2017-09-01

    Minimally invasive valve surgery represents a recent and significant advance in modern heart surgery. Indeed, many less invasive approaches for both the aortic and mitral valves have been developed in the past 2 decades. These procedures were hypothesized to result in less operative trauma, which might translate into better patient outcomes. However, this clinical benefit remains controversial in the literature. The aim of this review is to discuss the evidence surrounding minimally invasive heart valve surgery in the current era. A systematic search of the literature from 2006-2016 was performed looking for articles reporting early or late outcomes after minimally invasive valve surgery. Less invasive valve surgery is safe and provides long-term surgical outcomes similar to those of standard sternotomy. In addition, these approaches result in a reduction in overall hospital length of stay and may mitigate the risk of early morbidity-mainly postoperative bleeding, transfusions, and ventilation duration. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  4. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive...... in Denmark who had received a Mitroflow aortic bioprosthesis since 2000. METHODS: Patients alive in Denmark with a Mitroflow bioprosthesis implanted since January 2000 were invited to participate in a nationwide cross-sectional study with a predefined definition of SVD. Of 1552 patients, 861 patients had...

  5. Method for removing soot from exhaust gases

    Energy Technology Data Exchange (ETDEWEB)

    Suib, Steven L.; Dharmarathna, D. A. Saminda; Pahalagedara, Lakshitha R.

    2018-01-16

    A method for oxidizing soot from diesel exhaust gas from a diesel engine. The method involves providing a diesel particulate filter for receiving the diesel exhaust gas; coating a catalyst composition on the diesel particulate filter; and contacting the soot from the diesel exhaust gas with the catalyst coated diesel particulate filter at a temperature sufficient to oxidize the soot to carbon dioxide. The catalyst composition is a doped or undoped manganese oxide octahedral molecular sieve (OMS-2) material. A diesel exhaust gas treatment system that includes a diesel particulate filter for receiving diesel exhaust gas from a diesel engine and collecting soot; and a catalyst composition coated on the diesel particulate filter. The catalyst composition is a doped or undoped manganese oxide octahedral molecular sieve (OMS-2).

  6. Development of mechanical heart valves - an inspiring tale

    Directory of Open Access Journals (Sweden)

    P Rajashekar

    2015-01-01

    Full Text Available The historical evolution of the prosthetic heart valves from the first attempts with the Hufnagel′s valve in the treatment of the aortic insufficiency to the Starr-Edwards′ ball valve and later the tilting disc valves (Bjork-Shiley etc., and finally the bileaflet valves (St. Jude are discussed. The Indian contribution with Chitra valve is also described.

  7. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves

    Science.gov (United States)

    van Rensburg, Annari; Doubell, Anton

    2017-01-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P abnormal papillary muscles (P = 0.002) and an additional chord or tendon in the left ventricle cavity (P = 0.007). Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. PMID:28515127

  8. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  9. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves.

    Science.gov (United States)

    van Rensburg, Annari; Herbst, Philip; Doubell, Anton

    2017-06-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P mitral regurgitation (P Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. © 2017 The authors.

  10. Should a Regurgitant Mitral Valve Be Replaced Simultaneously with a Stenotic Aortic Valve?

    OpenAIRE

    Christenson, Jan T.; Jordan, Bernard; Bloch, Antoine; Schmuziger, Martin

    2000-01-01

    Mitral valve regurgitation frequently accompanies aortic valve stenosis. It has been suggested that mitral regurgitation improves after aortic valve replacement alone and that the mitral valve need not be replaced simultaneously. Furthermore, mitral regurgitation associated with coronary artery disease, particularly in patients with poor left ventricular function, shows immediate improvement after coronary artery bypass grafting.

  11. Emotionally exhausting factors in general practitioners’ work

    Science.gov (United States)

    Torppa, M.A.; Kuikka, L.; Nevalainen, M.; Pitkälä, K.H.

    2015-01-01

    Background. Emotional exhaustion is central in burnout syndrome and signals its development. General practitioners’ (GP) work is emotionally challenging but research on these aspects is lacking. Objective. To study the prevalence of emotional exhaustion among GPs and to evaluate how their characteristics and work experiences are associated with emotional exhaustion. Design and methods. A questionnaire survey was carried out among GPs in Finland in 2011 in which questions were posed regarding their experience of emotional exhaustion and items related to their work experiences and professional identity. A statement “I feel burnt out from my job” (never, seldom, sometimes, quite often, or often) enquired about emotional exhaustion. Those responding quite often or often were categorized as emotionally exhausted. Results. Among the GPs, 68% responded (165/244). Of the respondents, 18% were emotionally exhausted. Emotional exhaustion was associated with older age, longer working history, experiences of having too much work, fear and reports of having committed a medical error, low tolerance of uncertainty in their work, and feeling alone at work. No differences in positive work experiences were found. In logistic regression analysis working experience > 5 years (OR 4.1, 95% CI 1.6–10.8; p = 0.0036) and feeling alone at work (OR 2.9, 95% CI 1.2–7.1; p = 0.020) predicted emotional exhaustion, having committed a medical error in the past three months predicted it marginally significantly (OR 2.4, 95% CI 1.0–5.9, p = 0.057), whereas tolerating uncertainty well protected against it (OR 0.2, 95% CI 0.09–0.7; p = 0.0098). Conclusions. Emotional exhaustion among GPs was common and associated with longer working history, having committed a medical error, and feelings of isolation at work. GPs should receive more support throughout their careers. PMID:26311207

  12. Health effects of exhaust particles

    Energy Technology Data Exchange (ETDEWEB)

    Pihlava, T.; Uuppo, M.; Niemi, S.

    2013-11-01

    This report introduces general information about diesel particles and their health effects. The purpose of this report is to introduce particulate matter pollution and present some recent studies made regarding the health effects of particulate matter. The aim is not to go very deeply into the science, but instead to keep the text understandable for the average layman. Particulate matter is a complex mixture of extremely small particles and liquid droplets. These small particles are made up of a number of components that include for example acids, such as nitrates and sulphates, as well as organic chemicals, metals and dust particles from the soil. Particulate matter comes from several sources, such as transportation emissions, industrial emissions, forest fires, cigarette smoke, volcanic ash and climate variations. Particles are divided into coarse particles with diameters less than 10 ..m, fine particles with diameters smaller than 2.5 ..m and ultra-fine particles with diameters less than 0.1 ..m. The particulate matter in diesel exhaust gas is a highly complex mixture of organic, inorganic, solid, volatile and partly volatile compounds. Many of these particles do not form until they reach the air. Many carcinogenic compounds have been found in diesel exhaust gas and it is considered carcinogenic to humans. Particulate matter can cause several health effects, such as premature death in persons with heart or lung disease, cancer, nonfatal heart attacks, irregular heartbeat, aggravated asthma, decreased lung function and an increase in respiratory symptoms, such as irritation of the airways, coughing or difficulty breathing. It is estimated that in Finland about 1300 people die prematurely due to particles and the economic loss in the EU due to the health effects of particles can be calculated in the billions. Ultra-fine particles are considered to be the most harmful to human health. Ultrafine particles usually make the most of their quantity and surface area

  13. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  14. Active combustion flow modulation valve

    Science.gov (United States)

    Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

    2013-09-24

    A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

  15. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  16. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  17. Pregnancy-induced remodeling of heart valves.

    Science.gov (United States)

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves. Copyright © 2015 the American Physiological Society.

  18. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Rho, Hyung Joon; Lee, Jee Keun [Chonbuk National Univ., Jeonju (Korea, Republic of); Choi, Hee Joo [Firstec Co., Ltd., Changwon (Korea, Republic of)

    2008-01-15

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk.

  19. 49 CFR 195.420 - Valve maintenance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance. 195.420 Section 195.420 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each valve...

  20. Double orifice mitral valve; a coincidental finding

    NARCIS (Netherlands)

    Westendorp, Iris C. D.; de Bruin-Bon, H. A. C. M.; Hrudova, Jana

    2006-01-01

    A double orifice mitral valve (DOMV) represents a rare congenital malformation characterised by two valve orifices with two separate subvalvular apparatus. This case demonstrates the necessity of careful imaging of the mitral valve apparatus, not only in patients with atrioventricular septal

  1. Pregnancy in women with prosthetic heart valves

    NARCIS (Netherlands)

    Pieper, P. G.; Balci, A.; Van Dijk, A. P.

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis mid death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than unfractionated and low-molecular-weight heparin, but carry the risk

  2. Pregnancy in women with prosthetic heart valves.

    NARCIS (Netherlands)

    Pieper, P.G.; Balci, A.; Dijk, A.P.J. van

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis and death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than un-fractionated and low-molecular-weight heparin, but carry the risk

  3. Transcatheter mitral valve implantation via transapical approach

    DEFF Research Database (Denmark)

    Sondergaard, Lars; Brooks, Matthew; Ihlemann, Nikolaj

    2015-01-01

    OBJECTIVES: As many as 50% of patients with severe symptomatic mitral valve regurgitation are denied surgical valve replacement or repair due to high operative risk. We describe an early series of cases of transcatheter implantation with a CardiAQ™ mitral valve via a transapical approach. METHODS...

  4. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  5. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  6. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  7. [The Starr-Edwards heart valve: one of the oldest mechanical heart valves still functioning today].

    Science.gov (United States)

    Schoenaker, Michiel H; van Wetten, Herbert B; Morshuis, Wim J

    2015-01-01

    In the 1960s, the Starr-Edwards valve was the first artificial heart valve to be successfully implanted in humans. This valve has now been in use for decades with outstanding results: patients whose life expectancy had previously been short acquired a good prognosis with this development. Nowadays the Starr-Edwards valve is not used anymore, but patients are being described today in whom these valves are still functioning well after more than 40 years.

  8. 40 CFR 90.407 - Engine inlet and exhaust systems.

    Science.gov (United States)

    2010-07-01

    ... exhaust emission compliance over the full range of air inlet filter systems and exhaust muffler systems. (b) The air inlet filter system and exhaust muffler system combination used on the test engine must...

  9. Exhaust gas recirculation system for an internal combustion engine

    Science.gov (United States)

    Wu, Ko-Jen

    2013-05-21

    An exhaust gas recirculation system for an internal combustion engine comprises an exhaust driven turbocharger having a low pressure turbine outlet in fluid communication with an exhaust gas conduit. The turbocharger also includes a low pressure compressor intake and a high pressure compressor outlet in communication with an intake air conduit. An exhaust gas recirculation conduit fluidly communicates with the exhaust gas conduit to divert a portion of exhaust gas to a low pressure exhaust gas recirculation branch extending between the exhaust gas recirculation conduit and an engine intake system for delivery of exhaust gas thereto. A high pressure exhaust gas recirculation branch extends between the exhaust gas recirculation conduit and the compressor intake and delivers exhaust gas to the compressor for mixing with a compressed intake charge for delivery to the intake system.

  10. Exhaustion and the Pathologization of Modernity.

    Science.gov (United States)

    Schaffner, Anna Katharina

    2016-09-01

    This essay analyses six case studies of theories of exhaustion-related conditions from the early eighteenth century to the present day. It explores the ways in which George Cheyne, George Beard, Richard von Krafft-Ebing, Sigmund Freud, Alain Ehrenberg and Jonathan Crary use medical ideas about exhaustion as a starting point for more wide-ranging cultural critiques related to specific social and technological transformations. In these accounts, physical and psychological symptoms are associated with particular external developments, which are thus not just construed as pathology-generators but also pathologized. The essay challenges some of the persistently repeated claims about exhaustion and its unhappy relationship with modernity.

  11. Imaging of Cardiac Valves by Computed Tomography

    OpenAIRE

    Gudrun Feuchtner

    2013-01-01

    This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use ...

  12. Field Experience with Lock Culvert Valves

    Science.gov (United States)

    2013-12-01

    interesting accounts regarding their lock culvert valves. ST. LAWRENCE SEAWAY Eisenhower and Snell Locks. The valves on the Eisenhower and Snell Locks...Tainter Valve Design Lift, ft Eisenhower St. Lawrence Seaway 80 x 860 12 x 14 21.0 DSP 43 Snell St. Lawrence Seaway 80 x 860 12 x 14 21.0 3 DSP, 1 VF 49...vertical-frame valves were furnished to the SLSDC in January 2011, and one was installed in the south filling-valve location at Snell Lock. An option

  13. Isolated tricuspid valve infective endocarditis

    African Journals Online (AJOL)

    1990-07-07

    Jul 7, 1990 ... Case 2. Initial chest radiograph showing rounded shadows with cavitation. Fig. 2. Case 2. Chest radiograph showing progression to effusion. nuc/eacum was Isolated from repeated blood cultures. Two- dimensional echocardiography revealed vegetations on the tricuspid valve (Fig. 3). The patient was now ...

  14. Optothermally actuated capillary burst valve

    DEFF Research Database (Denmark)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders

    2017-01-01

    be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett...

  15. Mitral valve surgery - minimally invasive

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  16. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  17. Hemodynamics driven cardiac valve morphogenesis.

    Science.gov (United States)

    Steed, Emily; Boselli, Francesco; Vermot, Julien

    2016-07-01

    Mechanical forces are instrumental to cardiovascular development and physiology. The heart beats approximately 2.6 billion times in a human lifetime and heart valves ensure that these contractions result in an efficient, unidirectional flow of the blood. Composed of endocardial cells (EdCs) and extracellular matrix (ECM), cardiac valves are among the most mechanically challenged structures of the body both during and after their development. Understanding how hemodynamic forces modulate cardiovascular function and morphogenesis is key to unraveling the relationship between normal and pathological cardiovascular development and physiology. Most valve diseases have their origins in embryogenesis, either as signs of abnormal developmental processes or the aberrant re-expression of fetal gene programs normally quiescent in adulthood. Here we review recent discoveries in the mechanobiology of cardiac valve development and introduce the latest technologies being developed in the zebrafish, including live cell imaging and optical technologies, as well as modeling approaches that are currently transforming this field. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel. Copyright © 2015. Published by Elsevier B.V.

  18. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis

    DEFF Research Database (Denmark)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected fo...

  19. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... called stenosis). • Don’t close properly and let blood leak where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t close properly (more common in women).As pressure builds inside the left ventricle, it pushes the ...

  20. Taxation of exhaustible resources. [Monograph

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, P.; Heal, G.; Stiglitz, J.

    1980-01-01

    This paper analyzes the effect of taxation on the intertemporal allocation of an exhaustible resource. A general framework within which a large variety of taxes can be analyzed is developed and then applied to a number of specific taxes. It is shown that there exists a pattern of taxation which can generate essentially any desired pattern of resource usage. Many tax policies, however, have effects markedly different both from the effects that these policies would have in the case of produced commodities and from those which they are designed (or widely thought) to have. For instance, if extraction costs are zero, a depletion allowance at a constant rate (widely thought to encourage the extraction of resources) has absolutely no effect; its gradual removal (usually thought to be preferable to a sudden removal) leads to faster rates of depletion (and lower prices) now, but higher prices in the future; which its sudden and unanticipated removal has absolutely no distortionary effect on the pattern of extraction. More generally, it is shown that the effects of tax structure on the patterns of extraction are critically dependent on expectations concerning future taxation. The changes in tax structure that have occurred in the past fifty years are of the kind that, if they were anticipated, (or if similar further changes are expected to occur in the future) lead to excessively fast exploitation of natural resources. However, if it is believed that current tax policies (including rates) will persist indefinitely, the current tax structure would lead to excessive conservationism. Thus, whether in fact current tax policies have lead to excessive conservationism is a moot question.

  1. Manufacturable plastic microfluidic valves using thermal actuation.

    Science.gov (United States)

    Pitchaimani, Karthik; Sapp, Brian C; Winter, Adam; Gispanski, Austin; Nishida, Toshikazu; Hugh Fan, Z

    2009-11-07

    A low-cost, manufacturable, thermally actuated, plastic microfluidic valve has been developed. The valve contains an encapsulated, temperature-sensitive fluid, which expands, deflecting a thin elastomeric film into a fluidic channel to control fluid flow. The power input for thermal expansion of each microfluidic valve can be controlled using a printed circuit board (PCB)-based controller, which is suitable for mass production and large-scale integration. A plastic microfluidic device with such valves was fabricated using compression molding and thermal lamination. The operation of the valves was investigated by measuring a change in the microchannel's ionic conduction current mediated by the resistance variation corresponding to the deflection of the microvalve. Valve closing was also confirmed by the disappearance of fluorescence when a fluorescent solution was displaced in the valve region. Valve operation was characterized for heater power ranging from 36 mW to 80 mW. When the valve was actuating, the local channel temperature was 10 to 19 degrees C above the ambient temperature depending on the heater power used. Repetitive valve operations (up to 50 times) have been demonstrated with a flow resulting from a hydrostatic head. Valve operation was tested for a flow rate of 0.33-4.7 microL/min.

  2. Mitral Valve Disease: a Comprehensive Review.

    Science.gov (United States)

    Harb, Serge C; Griffin, Brian P

    2017-08-01

    This review aims to provide a comprehensive assessment of mitral valve disease, both mitral stenosis and mitral regurgitation, starting with an overview of the valve anatomy. The advent of three-dimensional imaging has allowed a better representation of the valve anatomy. Rheumatic disease is still the number one cause of mitral stenosis worldwide and percutaneous balloon mitral valvuloplasty remains the therapy of choice when indicated and in anatomically eligible patients. Mitral regurgitation (MR) is classified as primary (i.e., lesion in the mitral apparatus) or secondary (caused by left ventricular geometrical alterations). While surgery, preferably repair, is still the recommended therapy for severe primary MR, percutaneous approaches to repair and/or replace the mitral valve are being extensively investigated. Mitral valve disease is common. A careful understanding of mitral valve anatomy and the disease processes that affect the valve are crucial for providing optimal patient care.

  3. Mitral Valve Repair: The Chordae Tendineae

    Directory of Open Access Journals (Sweden)

    Carlos-A Mestres

    2015-10-01

    Full Text Available Repair of the mitral valve is the treatment of choice for mitral valve regurgitation when the anatomy is favorable. It is well known that mitral valve repair enjoys better clinical and functional results than any other type of valve substitute. This fact is beyond doubt regardless of the etiology of the valve lesion and is of particular importance in degenerative diseases.This review analyzes the most important advances in the knowledge of the anatomy, pathophysiology, and chordal function of the mitral valve as well as the different alternatives in the surgical repair and clinical results of the most prevalent diseases of the mitral valve. An attempt has been made to organize the acquired information available in a practical way.

  4. An exploratory drilling exhaustion sequence plot program

    Science.gov (United States)

    Schuenemeyer, J.H.; Drew, L.J.

    1977-01-01

    The exhaustion sequence plot program computes the conditional area of influence for wells in a specified rectangular region with respect to a fixed-size deposit. The deposit is represented by an ellipse whose size is chosen by the user. The area of influence may be displayed on computer printer plots consisting of a maximum of 10,000 grid points. At each point, a symbol is presented that indicates the probability of that point being exhausted by nearby wells with respect to a fixed-size ellipse. This output gives a pictorial view of the manner in which oil fields are exhausted. In addition, the exhaustion data may be used to estimate the number of deposits remaining in a basin. ?? 1977.

  5. Exhaustivity and intonation: a unified theory

    NARCIS (Netherlands)

    Westera, M.

    2017-01-01

    This dissertation presents a precise, unified and explanatory theory of human conversation, centered on two broad phenomena: exhaustivity implications and intonational meaning. In a nutshell: (i) speakers have two types of communicative intentions, namely information sharing and attention sharing,

  6. Conical Seat Shut-Off Valve

    Science.gov (United States)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  7. Fuel consumption and exhaust emissions of aircrafts

    Energy Technology Data Exchange (ETDEWEB)

    Buechler, R. [Institute of Flightmechanics, Braunschweig (Germany)

    1997-12-31

    The reduction of contamination of sensitive atmospheric layers by improved flight planning steps, is investigated. Calculated results have shown, that a further development of flight track planning allows considerable improvements on fuel consumption and exhaust emissions. Even if air traffic will further increase, optimistic investigations forecast a reduction of the environmental damage by aircraft exhausts, if the effects of improved flight track arrangement and engine innovations will be combined. (R.P.) 4 refs.

  8. Jet Engine Exhaust Analysis by Subtractive Chromatography

    Science.gov (United States)

    1978-12-01

    hydrocarbon ( TIIC ) results for the March 1975 jet engine exhaust studies ......... .............. 11 3. Specific retention volumes (Vg) for selected...studies with subsequent low TiIC recove.’cries. At least three factors could singly or in combination bu I responsible for exceeding the trap capacities: 1...effective system for collectingq crqanics : in jet engine exhaust. The success of these modifications is illustrated by t.he TIIC recovery data compared

  9. T cell exhaustion and Interleukin 2 downregulation.

    Science.gov (United States)

    Balkhi, Mumtaz Y; Ma, Qiangzhong; Ahmad, Shazia; Junghans, Richard P

    2015-02-01

    T cells reactive to tumor antigens and viral antigens lose their reactivity when exposed to the antigen-rich environment of a larger tumor bed or viral load. Such non-responsive T cells are termed exhausted. T cell exhaustion affects both CD8+ and CD4+ T cells. T cell exhaustion is attributed to the functional impairment of T cells to produce cytokines, of which the most important may be Interleukin 2 (IL2). IL2 performs functions critical for the elimination of cancer cells and virus infected cells. In one such function, IL2 promotes CD8+ T cell and natural killer (NK) cell cytolytic activities. Other functions include regulating naïve T cell differentiation into Th1 and Th2 subsets upon exposure to antigens. Thus, the signaling pathways contributing to T cell exhaustion could be linked to the signaling pathways contributing to IL2 loss. This review will discuss the process of T cell exhaustion and the signaling pathways that could be contributing to T cell exhaustion. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A New Hemostasis Valve for Neuroendovascular Procedures

    Science.gov (United States)

    Namba, K.; Song, J.K.; Niimi, Y.; Heran, N.S.; Berenstein, A.

    2007-01-01

    Summary A hemostasis valve is routinely used in neuroendovascular procedures to decrease the risk of thromboembolism1,2. Recently, a new hemostasis valve that is designed to minimize blood loss has been introduced. We report our initial experience in using this new hemostasis valve. In neuroendovascular procedures, a hemostasis valve is commonly used for continuous irrigation of guide and microcatheters to decrease the risk of thromboembolism1,2,3. A conventional hemostasis valve has a rotating seal at the end, which is turned open or closed each time a wire or microcatheter/guidewire is introduced or extracted. Often this results in significant back bleeding. When a rotating seal is adjusted suboptimally during a wire or microcatheter manipulation, leakage of pressurized saline from the end of a hemostasis valve results in stagnation of blood within a guiding catheter, which becomes a potential source of emboli during a procedure. The Guardian Haemostasis Valve (Zerusa Limited, Galway, Ireland) is a new hemostasis valve that is designed to minimize blood loss during interventional procedures by minimizing the opening time of the valve during wire or microcatheter insertion. A continuous sealing mechanism during wire or microcatheter positioning minimizes blood loss and stagnation of blood within the guide catheter. We report our initial experience with the Guardian hemostasis valve. PMID:20566129

  11. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    Science.gov (United States)

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  12. Contemporary outcomes in reoperative mitral valve surgery.

    Science.gov (United States)

    Mehaffey, Hunter J; Hawkins, Robert B; Schubert, Sarah; Fonner, Clifford; Yarboro, Leora T; Quader, Mohammed; Speir, Alan; Rich, Jeff; Kron, Irving L; Ailawadi, Gorav

    2017-10-05

    Data suggest that redo mitral valve surgery is being performed in increasing numbers, possibly with superior results according to single-centre studies. The purpose of this study is to describe outcomes of redo mitral valve surgery and identify risk-adjusted predictors of poor outcomes. All (11 973) open mitral valve cases were evaluated (2002-2016) from a regional Society of Thoracic Surgery (STS) database. Patients were stratified by primary versus redo mitral valve surgery. Mixed effects logistic regression models including hospital as a random effect were used to identify risk factors for patients undergoing redo mitral valve surgery. Of all mitral valve cases, 1096 (9.7%) had a previous mitral operation. Redo patients had higher rates of valve replacement and preoperative comorbidities resulting in more complications, operative mortalities (11.1%vs6.5%, pmitral valve surgery increased 10% per year and the observed-to-expected ratios (O/E) for operative mortality in redo mitral surgery improved from 1.44 early in the study period to 0.72 in the most recent era. Redo mitral valve surgery accounts for approximately 10% of mitral valve operations and is associated with increased risk and resource utilisation. However, as the volume of redo mitral surgery increases, outcomes have dramatically improved and are now better than predicted. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  14. Bioprosthetic heart valves of the future.

    Science.gov (United States)

    Manji, Rizwan A; Ekser, Burcin; Menkis, Alan H; Cooper, David K C

    2014-01-01

    Glutaraldehyde-fixed bioprosthetic heart valves (GBHVs), derived from pigs or cows, undergo structural valve deterioration (SVD) over time, with calcification and eventual failure. It is generally accepted that SVD is due to chemical processes between glutaraldehyde and free calcium ions in the blood. Valve companies have made significant progress in decreasing SVD from calcification through various valve chemical treatments. However, there are still groups of patients (e.g., children and young adults) that have accelerated SVD of GBHV. Unfortunately, these patients are not ideal patients for valve replacement with mechanical heart valve prostheses as they are at high long-term risk from complications of the mandatory anticoagulation that is required. Thus, there is no "ideal" heart valve replacement for children and young adults. GBHVs represent a form of xenotransplantation, and there is increasing evidence that SVD seen in these valves is at least in part associated with xenograft rejection. We review the evidence that suggests that xenograft rejection of GBHVs is occurring, and that calcification of the valve may be related to this rejection. Furthermore, we review recent research into the transplantation of live porcine organs in non-human primates that may be applicable to GBHVs and consider the potential use of genetically modified pigs as sources of bioprosthetic heart valves. © 2014 John Wiley & Sons A/S.

  15. 14 CFR 29.1125 - Exhaust heat exchangers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Exhaust heat exchangers. 29.1125 Section 29... exchangers. For reciprocating engine powered rotorcraft the following apply: (a) Each exhaust heat exchanger... is subject to contact with exhaust gases; and (4) No exhaust heat exchanger or muff may have stagnant...

  16. 14 CFR 25.1125 - Exhaust heat exchangers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Exhaust heat exchangers. 25.1125 Section 25... exchangers. For reciprocating engine powered airplanes, the following apply: (a) Each exhaust heat exchanger... provisions wherever it is subject to contact with exhaust gases; and (4) No exhaust heat exchanger or muff...

  17. 40 CFR 1065.330 - Exhaust-flow calibration.

    Science.gov (United States)

    2010-07-01

    ... recommend that you use a calibration subsonic venturi or ultrasonic flow meter and simulate exhaust temperatures by incorporating a heat exchanger between the calibration meter and the exhaust-flow meter. If you... Exhaust-flow calibration. (a) Calibrate exhaust-flow meters upon initial installation. Follow the...

  18. Bronchoalveolar inflammation after exposure to diesel exhaust: comparison between unfiltered and particle trap filtered exhaust.

    Science.gov (United States)

    Rudell, B; Blomberg, A; Helleday, R; Ledin, M C; Lundbäck, B; Stjernberg, N; Hörstedt, P; Sandström, T

    1999-08-01

    Air pollution particulates have been identified as having adverse effects on respiratory health. The present study was undertaken to further clarify the effects of diesel exhaust on bronchoalveolar cells and soluble components in normal healthy subjects. The study was also designed to evaluate whether a ceramic particle trap at the end of the tail pipe, from an idling engine, would reduce indices of airway inflammation. The study comprised three exposures in all 10 healthy never smoking subjects; air, diluted diesel exhaust, and diluted diesel exhaust filtered with a ceramic particle trap. The exposures were given for 1 hour in randomised order about 3 weeks apart. The diesel exhaust exposure apperatus has previously been carefully developed and evaluated. Bronchoalveolar lavage was performed 24 hours after exposures and the lavage fluids from the bronchial and bronchoalveolar region were analysed for cells and soluble components. The particle trap reduced the mean steady state number of particles by 50%, but the concentrations of the other measured compounds were almost unchanged. It was found that diesel exhaust caused an increase in neutrophils in airway lavage, together with an adverse influence on the phagocytosis by alveolar macrophages in vitro. Furthermore, the diesel exhaust was found to be able to induce a migration of alveolar macrophages into the airspaces, together with reduction in CD3+CD25+ cells. (CD = cluster of differentiation) The use of the specific ceramic particle trap at the end of the tail pipe was not sufficient to completely abolish these effects when interacting with the exhaust from an idling vehicle. The current study showed that exposure to diesel exhaust may induce neutrophil and alveolar macrophage recruitment into the airways and suppress alveolar macrophage function. The particle trap did not cause significant reduction of effects induced by diesel exhaust compared with unfiltered diesel exhaust. Further studies are warranted to

  19. Near net shape, low cost ceramic valves for advanced engine applications

    Energy Technology Data Exchange (ETDEWEB)

    Pidria, M.; Merlone, E.; Parussa, F. [Fiat Research Centre, Orbassano (Italy); Handelsman, J.; Gorodnev, A. [Ceracom Materials Ltd., Yavneh (Israel)

    2003-07-01

    Future gasoline and diesel engines with electro-hydraulic or electro-mechanical valve control systems require the development of lighter valves to achieve the best results in terms of increased performances, lower fuel consumption and overall efficiency. Ceramic materials can adequately satisfy the required mechanical and thermal properties, nevertheless they still lack as far as manufacturing costs are concerned. Objective of the work was the development of a low-cost forming and sintering process, to produce near-net shape ceramic valves thus requiring very low finishing operations and significantly minimizing material waste. Between available technical ceramic materials, silicon nitride has been chosen to replace conventional steels and Ni-based alloys for the exhaust valves application. The work was then devoted to (i) the selection of the best starting materials composition, taking into account the requirements of a cost effective and high volume production, (ii) the development of an innovative pressure-injection molding process to produce near-net shape parts via a thermosetting feedstock and (iii) the optimization of a proper pressure-less sintering route to obtain cost-competitive, real scale components with adequate final density and mechanical properties. (orig.)

  20. Flow Characteristics of Butterfly Valve by PIV and CFD

    Science.gov (United States)

    Kim, S. W.; Kim, J. H.; Choi, Y. D.; Lee, Y. H.

    Butterfly valves are widely used as on-off and control valves for industrial process. The importance of butterfly valves as control valves has been increasing because the pressure loss is smaller than other types of valves and compactness is very desirable for installation. These features are desirable for saving energy and high efficiency of instruments.

  1. Mechanical valves in the pulmonary position : An international retrospective analysis

    NARCIS (Netherlands)

    Pragt, Hanna; van Melle, Joost P.; Javadikasgari, Hoda; Seo, Dong Man; Stulak, John M.; Knez, Igor; Hoerer, Juergen; Munoz-Guijosa, Christian; Dehaki, Mahyar G.; Shin, Hong Ju; Dearani, Joseph A.; Dehaki, Maziar G.; Pieper, Petronella G.; Eulenburg, Christine; Dos, Laura; Ebels, Tjark

    2017-01-01

    Objective: Life expectancy of patients with congenital heart disease has improved over the past decades, increasing the need for a durable pulmonary prosthetic valve. Biological valves in various forms have become the valve of choice for pulmonary valve replacement (PVR), but structural valve

  2. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR.

  3. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  4. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  5. Effect of EGR on the exhaust gas temperature and exhaust opacity ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Hence, in order to meet the envi- ronmental legislations, it is highly desirable to reduce the amount of NOx in the exhaust gas. 275 .... (i) Hot EGR: Exhaust gas is recirculated without being cooled, resulting in increased intake ... is mounted on the inlet pipe between the air filter and the inlet manifold of the engine as shown in ...

  6. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  7. 3D Printed Multimaterial Microfluidic Valve.

    Science.gov (United States)

    Keating, Steven J; Gariboldi, Maria Isabella; Patrick, William G; Sharma, Sunanda; Kong, David S; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  8. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), inclu...... population. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01057173....

  9. Vital Exhaustion and Coronary Heart Disease Risk

    DEFF Research Database (Denmark)

    Frestad, Daria; Prescott, Eva

    2017-01-01

    OBJECTIVES: The construct of vital exhaustion has been identified as a potential independent psychological risk factor for incident and recurrent coronary heart disease (CHD). Despite several decades of research, no systematic review or meta-analysis has previously attempted to collate the empiri......OBJECTIVES: The construct of vital exhaustion has been identified as a potential independent psychological risk factor for incident and recurrent coronary heart disease (CHD). Despite several decades of research, no systematic review or meta-analysis has previously attempted to collate...... the empirical evidence in this field. The purpose of this study was to review and quantify the impact of vital exhaustion on the development and progression of CHD. METHODS: Prospective and case-control studies reporting vital exhaustion at baseline and CHD outcomes at follow-up were derived from PubMed, Psyc...... by two authors. RESULTS: Thirteen prospective (n = 52,636) and three case-control (cases, n = 244; controls, n = 457) studies assessed vital exhaustion and could be summarized in meta-analyses. The pooled adjusted risk of CHD in healthy populations was 1.50 (95% confidence interval [CI] = 1...

  10. Performance of Installed Cooking Exhaust Devices

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Delp, William W.; Apte, Michael G.; Price, Philip N.

    2011-11-01

    The performance metrics of airflow, sound, and combustion product capture efficiency (CE) were measured for a convenience sample of fifteen cooking exhaust devices, as installed in residences. Results were analyzed to quantify the impact of various device- and installation-dependent parameters on CE. Measured maximum airflows were 70% or lower than values noted on product literature for 10 of the devices. Above-the-cooktop devices with flat bottom surfaces (no capture hood) – including exhaust fan/microwave combination appliances – were found to have much lower CE at similar flow rates, compared to devices with capture hoods. For almost all exhaust devices and especially for rear-mounted downdraft exhaust and microwaves, CE was substantially higher for back compared with front burner use. Flow rate, and the extent to which the exhaust device extends over the burners that are in use, also had a large effect on CE. A flow rate of 95 liters per second (200 cubic feet per minute) was necessary, but not sufficient, to attain capture efficiency in excess of 75% for the front burners. A-weighted sound levels in kitchens exceeded 57 dB when operating at the highest fan setting for all 14 devices evaluated for sound performance.

  11. Engineering task plan for five portable exhausters

    Energy Technology Data Exchange (ETDEWEB)

    Rensink, G.E.

    1997-10-01

    Exhausters will be employed to ventilate certain single-shell tanks (SSTs) during salt well pumping campaigns. Active ventilation is necessary to reduce the potential flammable gas inventory (LANL 1996a) in the dome space that may accumulate during steady-state conditions or during/after postulated episodic gas release events. The tanks described in this plan support the activities required to fabricate and test three 500 cfm portable exhausters in the 200 W area shops, and to procure, design, fabricate and test two 1000 cfm units. Appropriate Notice of Construction (NOC) radiological and toxic air pollutant permits will be obtained for the portable exhausters. The portable exhauster design media to be employed to support this task was previously developed for the 241-A-101 exhauster. The same design as A101 will be fabricated with only minor improvements to the design based upon operator input/lessons learned. The safety authorization basis for this program effort will follow SAD 36 (LANL 1996b), and each tank will be reviewed against this SAD for changes or updates. The 1000 cfm units will be designed by the selected offsite contractor according to the specification requirements in KHC-S-O490. The offsite units have been specified to utilize as many of the same components as the 500 cfm units to ensure a more cost effective operation and maintenance through the reduction of spare parts and additional procedures.

  12. Simplified surgical-hybrid Melody® valve implantation for paediatric mitral valve disease

    OpenAIRE

    Hofmann, Michael; Dave, Hitendu; Hübler, Michael; Kretschmar, Oliver

    2017-01-01

    Children suffering from left atrioventricular valve (LAVV) disease not amenable to repair represent a significant challenge. The results of surgical reconstruction are not optimal. Valve replacement as an alternative is associated with poor results. The surgical-hybrid approach with implantation of a stented biological valve (bovine jugular vein graft, Melody® valve) seems to represent a new therapeutic option. Here we demonstrate our case, the consideration and the approach to extreme clinic...

  13. Lightweight Exhaust Manifold and Exhaust Pipe Ducting for Internal Combustion Engines

    Science.gov (United States)

    Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    1999-01-01

    An improved exhaust system for an internal combustion gasoline-and/or diesel-fueled engine includes an engine exhaust manifold which has been fabricated from carbon- carbon composite materials in operative association with an exhaust pipe ducting which has been fabricated from carbon-carbon composite materials. When compared to conventional steel. cast iron. or ceramic-lined iron paris. the use of carbon-carbon composite exhaust-gas manifolds and exhaust pipe ducting reduces the overall weight of the engine. which allows for improved acceleration and fuel efficiency: permits operation at higher temperatures without a loss of strength: reduces the "through-the wall" heat loss, which increases engine cycle and turbocharger efficiency and ensures faster "light-off" of catalytic converters: and, with an optional thermal reactor, reduces emission of major pollutants, i.e. hydrocarbons and carbon monoxide.

  14. Propellant actuated nuclear reactor steam depressurization valve

    Science.gov (United States)

    Ehrke, Alan C.; Knepp, John B.; Skoda, George I.

    1992-01-01

    A nuclear fission reactor combined with a propellant actuated depressurization and/or water injection valve is disclosed. The depressurization valve releases pressure from a water cooled, steam producing nuclear reactor when required to insure the safety of the reactor. Depressurization of the reactor pressure vessel enables gravity feeding of supplementary coolant water through the water injection valve to the reactor pressure vessel to prevent damage to the fuel core.

  15. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  16. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  17. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  18. Percutaneous approaches to mitral valve disease

    National Research Council Canada - National Science Library

    Fassa, A-A; Himbert, D; Brochet, E; Bouleti, C; Vahanian, A

    2015-01-01

    Percutaneous approaches to mitral valve disease consist in modifications of existing surgical techniques, aiming to replicate the favourable outcomes of surgery, with less procedure-related risk, due...

  19. Hammock mitral valve: A rare case report

    Directory of Open Access Journals (Sweden)

    Veeresh F. Manvi

    2014-01-01

    Full Text Available Congenital mitral stenosis is a relatively rare disorder comprising 0.2% of all congenital heart defects. Hammock mitral valve producing severe mitral stenosis is a rare variant of congenital mitral stenosis. We report a 2-year-old boy who had hammock mitral valve producing severe mitral stenosis with severe pulmonary artery hypertension. He underwent successful surgical repair. Post-surgery, the mitral valve opening was adequate without residual stenosis or regurgitation. Pulmonary artery pressure had normalized. Follow-up data showed he had significant clinical and echocardiography improvement. This is the first reported case of successful surgical repair done for hammock mitral valve from our institute.

  20. Stentless aortic valve replacement: an update

    Directory of Open Access Journals (Sweden)

    Kobayashi J

    2011-06-01

    Full Text Available Junjiro KobayashiDepartment of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, Osaka, JapanAbstract: Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient–prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose of this review is to provide a current overview of stentless valves in the aortic position. Retrospective and prospective randomized controlled studies showed similar operative mortality and morbidity in stented and stentless aortic valve replacement (AVR, though stentless AVR required longer cross-clamp and cardiopulmonary bypass time. Several cohort studies showed improved survival after stentless AVR, probably due to better hemodynamic performance and earlier left ventricular (LV mass regression compared with stented AVR. However, there was a bias of operation age and nonrandomization. A randomized trial supported an improved 8-year survival of patients with the Freestyle or Toronto valves compared with Carpentier–Edwards porcine valves. On the contrary, another randomized study did not show improved clinical outcomes up to 12 years. Freedom from reoperation at 12 years in Toronto stentless porcine valves ranged from 69% to 75%, which is much lower than for Carpentier–Edwards Perimount valves. Cusp tear with consequent aortic regurgitation was the most common cause of structural valve deterioration. Cryolife O'Brien valves also have shorter durability compared with stent valves. Actuarial freedom from reoperation was 44% at 10 years. Early prosthetic valve failure was also reported in patients who underwent root replacement with Shelhigh stentless composite grafts. There was no level I or IIa evidence of more effective orifice

  1. Pump arrangement Comprising a Savety Valve

    OpenAIRE

    Richter, M.; Kruckow, J.

    2009-01-01

    A pump arrangement comprises a pump (20) having a pump inlet (22) and a pump outlet (24), which are designed to pump a fluid from the pump inlet to the pump outlet, and it further comprises a safety valve (40), which is disposed between the pump outlet (24) and an outlet (48) of the pump arrangement and comprises a valve set (42) and a valve cover (44). The valve seat, the pump outlet, and the pump inlet are structured in a first surface of a first single-piece part (14) of the pump arrangeme...

  2. Fracturing a dysfunctional Edwards Perimount bioprosthetic valve to facilitate percutaneous valve-in-valve placement of SAPIEN 3 valve with modified delivery system.

    Science.gov (United States)

    Shahanavaz, Shabana; Rockefeller, Toby; Nicolas, Ramzi; Balzer, David

    2017-10-10

    Pulmonary valve replacement via surgical implantation of a bioprosthetic valve (BPV) is a well-established treatment for patients with dysfunctional RV outflow tracts. BPVs are prone to structural deterioration, and will eventually require replacement. Recently, percutaneous valve-in-valve (VIV) placement of transcatheter valves has established itself as a safe and effective alternative to surgical revision. Unfortunately, VIV therapy is inherently limited by the inner diameter of the BPV, which restricts the number of eligible patients. Other centers have reported on the feasibility of cracking certain BPVs with ultra high-pressure balloons in bench testing. We now report cracking an Edwards Perimount BPV in the pulmonary position to facilitate VIV placement of an Edwards SAPIEN 3. The ability to crack the Perimount valve allowed placement of a larger valve than previously considered and minimized the final valve gradient. In an effort to avoid the morbidity and mortality of surgical pulmonary valve replacement, this new strategy will expand the number of patients eligible for percutaneous VIV therapy. © 2017 Wiley Periodicals, Inc.

  3. Aortic Calcification: An Early Sign of Heart Valve Problems?

    Science.gov (United States)

    ... the aortic valve — a condition called aortic valve stenosis. Aortic valve calcification may be an early sign ... have any other heart disease symptoms. Calcification and stenosis generally affects people older than age 65. When ...

  4. 40 CFR 63.175 - Quality improvement program for valves.

    Science.gov (United States)

    2010-07-01

    ... (e.g., ball, gate, check); valve manufacturer; valve design (e.g., external stem or actuating... categories, or classes, of valves as needed to distinguish among operating conditions and services associated...

  5. Exhaustive extraction of peptides by electromembrane extraction

    DEFF Research Database (Denmark)

    Huang, Chuixiu; Gjelstad, Astrid; Pedersen-Bjergaard, Stig

    2015-01-01

    This fundamental work illustrates for the first time the possibility of exhaustive extraction of peptides using electromembrane extraction (EME) under low system-current conditions (... 15% (v/v) DEHP was selected as a suitable SLM for exhaustive extraction of peptides under low system-current conditions. Interestingly, increasing the SLM volume from 5 to 10 μL was found to be beneficial for stable and efficient EME. The pH of the sample strongly affected the EME process, and pH 3.......5 was found to be optimal. The EME efficiency was also dependent on the acceptor solution composition, and the extraction time was found to be an important element for exhaustive extraction. When EME was carried out for 25 min with an extraction voltage of 15 V, the system-current across the SLM was less than...

  6. Prototype Variable-Area Exhaust Nozzle Designed

    Science.gov (United States)

    Lee, Ho-Jun; Song, Gangbring

    2005-01-01

    Ongoing research in NASA Glenn Research Center s Structural Mechanics and Dynamics Branch to develop smart materials technologies for adaptive aeropropulsion components has resulted in the design of a prototype variable-area exhaust nozzle (see the preceding photograph). The novel design exploits the potential of smart materials to improve the performance of existing fixed-area exhaust nozzles by introducing new capabilities for adaptive shape control, vibration damping, and flow manipulation. The design utilizes two different smart materials: shape memory alloy wires as actuators and magnetorheological fluids as damper locks.

  7. Neural activation in stress-related exhaustion

    DEFF Research Database (Denmark)

    Gavelin, Hanna Malmberg; Neely, Anna Stigsdotter; Andersson, Micael

    2017-01-01

    The primary purpose of this study was to investigate the association between burnout and neural activation during working memory processing in patients with stress-related exhaustion. Additionally, we investigated the neural effects of cognitive training as part of stress rehabilitation. Fifty......-five patients with clinical diagnosis of exhaustion disorder were administered the n-back task during fMRI scanning at baseline. Ten patients completed a 12-week cognitive training intervention, as an addition to stress rehabilitation. Eleven patients served as a treatment-as-usual control group. At baseline...

  8. Exhaustion of digital goods: An economic perspective

    OpenAIRE

    Kerber, Wolfgang

    2016-01-01

    The "UsedSoft" decision of the Court of Justice of the European Union (CJEU) about the right of a buyer of a downloaded copy of a software to resell this copy triggered a controversial discussion about the applicability of the "exhaustion" rule (US: first-sale doctrine) to copyright-protected digital goods (as, e.g., also e-books). This paper offers, in a first step, a systematic analysis and assessment of economic reasonings that have been discussed in the literature about exhaustion, and ap...

  9. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  10. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    -annular mechanical prostheses (CarboMedics, Inc., Arvada, CO, USA) at two institutions. Size frequency distribution was compared to published series, and to the manufacturer's US registry. The ventriculoaortic junction (VAJ) size was available in 234 patients, and compared to the size of the Top Hat valve implanted......BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...... is less than that of a normal valve. It is suggested that the ability to implant Top Hat valves having greater size, relative to standard intra-annular valves, may currently be under-utilized. Further, there has been some concern that Top Hat implantation can cause obstruction of the coronary ostia...

  11. Cylinder valve packing nut studies

    Energy Technology Data Exchange (ETDEWEB)

    Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

  12. Comparative toxicity and mutagenicity of biodiesel exhaust

    Science.gov (United States)

    Biodiesel (BD) is commercially made from the transesterification of plant and animal derived oils. The composition of biodiesel exhaust (BE) depends on the type of fuel, the blend ratio and the engine and operating conditions. While numerous studies have characterized the health ...

  13. Malaria drives T cells to exhaustion

    Directory of Open Access Journals (Sweden)

    Michelle N Wykes

    2014-05-01

    Full Text Available Malaria is a significant global burden but after >30 years of effort there is no vaccine on the market. While the complex life cycle of the parasite presents several challenges, many years of research have also identified several mechanisms of immune evasion by Plasmodium spp.. Recent research on malaria, has investigated the Programmed cell death-1 (PD-1 pathway which mediates exhaustion of T cells, characterized by poor effector functions and recall responses and in some cases loss of the cells by apoptosis. Such studies have shown exhaustion of CD4+ T cells and an unappreciated role for CD8+ T cells in promoting sterile immunity against blood stage malaria. This is because PD-1 mediates up to a 95% reduction in numbers and functional capacity of parasite-specific CD8+ T cells, thus masking their role in protection. The role of T cell exhaustion during malaria provides an explanation for the absence of sterile immunity following the clearance of acute disease which will be relevant to future malaria-vaccine design and suggests the need for novel therapeutic solutions. This review will thus examine the role of PD-1-mediated T cell exhaustion in preventing lasting immunity against malaria.

  14. The Effect of Unemployment Insurance Exhaustion

    DEFF Research Database (Denmark)

    Lyk-Jensen, Stéphanie; Weatherall, Cecilie Dohlmann

    . To identify the effect of UI exhaustion, we exploit the 1999 legislative change in the duration of benefit that progressively reduced regular UI entitlement from five to four years. According to time of entry into the UI system, all UI recipients had their potential UI period shortened. We use a competing...

  15. Emotional labour, emotional exhaustion, job satisfaction and ...

    African Journals Online (AJOL)

    This study investigated the relationship between emotional labour strategies, emotional exhaustion, job satisfaction and organisational citizenship behaviour among Korean fitness employees. Three hundred and sixty-six (n=366) fitness employees participated in a self-administered survey aimed at measuring the impact of ...

  16. Propagation of light through ship exhaust plumes

    Science.gov (United States)

    van Iersel, M.; Mack, A.; van Eijk, A. M. J.; Schleijpen, H. M. A.

    2014-10-01

    Looking through the atmosphere, it is sometimes difficult to see the details of an object. Effects like scintillation and blur are the cause of these difficulties. Exhaust plumes of e.g. a ship can cause extreme scintillation and blur, making it even harder to see the details of what lies behind the plume. Exhaust plumes come in different shapes, sizes, and opaqueness and depending on atmospheric parameters like wind speed and direction, as well as engine settings (power, gas or diesel, etc.). A CFD model is used to determine the plume's flow field outside the stack on the basis of exhaust flow properties, the interaction with the superstructure of the ship, the meteorological conditions and the interaction of ship's motion and atmospheric wind fields. A modified version of the NIRATAM code performs the gas radiation calculations and provides the radiant intensity of the (hot) exhaust gases and the transmission of the atmosphere around the plume is modeled with MODTRAN. This allows assessing the irradiance of a sensor positioned at some distance from the ship and its plume, as function of the conditions that influence the spatial distribution and thermal properties of the plume. Furthermore, an assessment can be made of the probability of detecting objects behind the plume. This plume module will be incorporated in the TNO EOSTAR-model, which provides estimates of detection range and image quality of EO-sensors under varying meteorological conditions.

  17. PHYSICO-CHEMICAL ASSESSMENT OF POMACE EXHAUSTED ...

    African Journals Online (AJOL)

    M’Sadak Y, Makhlouf M and El Amrouni S

    2016-05-01

    May 1, 2016 ... material (8 to 10% moisture), composed of fragments of olive stones and pulp. Such pomace, fine textured, rich in carbon and contains high amounts of lignin, cellulose and hemicellulose. (easily biodegradable polymers). 2.1.1. Quantitative characterization. The quantities of pomace exhausted have been ...

  18. The Heimlich Valve for Pleural Cavity Drainage

    African Journals Online (AJOL)

    The valve drains into a plastic bag that can be held at any level, allowing the patient to be ambulatory by carrying the bag. The construction and function of the valve is easily understood by medical and nursing staff. It is pre sterilized, stored in a sterile package, and readily utilized on emergency vehicles and in the operating.

  19. Numerical Analysis of Large Diameter Butterfly Valve

    Science.gov (United States)

    Youngchul, Park; Xueguan, Song

    In this paper, a butterfly valve with the diameter of 1,800 mm was studied. Three-dimensional numerical technique by using commercial code CFX were conducted to observe the flow patterns and to measure flow coefficient, hydrodynamic torque coefficient and so on, when the large butterfly valve operated with various angles and uniform incoming velocity.

  20. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    She delivered a normal baby uneventfully in follow up at full term of pregnancy with no complications. Fibrinolytic therapy for mechanical valve thrombosis is a reasonable alternative to surgery in first trimester of pregnancy. KEY WORDS: Prosthetic valve thrombosis; Echocardiography; Streptokinase;. Thrombolysis; Fetus.

  1. Sealing a Loosely Fitting Valve Assembly

    Science.gov (United States)

    Goff, L.; Tellier, G.

    1986-01-01

    Double-ring seal avoids expense of remachining or redesigning valve parts. Mating fittings on valve sealed by pair of rings - one O-ring and backup ring. Backup ring fills relatively large gap between parts. Prevents softer O-ring from being pushed into and through gap.

  2. Mitral valve disease--morphology and mechanisms.

    Science.gov (United States)

    Levine, Robert A; Hagége, Albert A; Judge, Daniel P; Padala, Muralidhar; Dal-Bianco, Jacob P; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H; Clusel, Catherine; Delling, Francesca N; Dietz, Harry C; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D; Jensen, Morten O; Jeunemaitre, Xavier P; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R; Mérot, Jean; Messas, Emmanuel; Milan, David P; Neri, Tui; Norris, Russell A; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A; Song, Jae-Kwan; Yacoub, Magdi H

    2015-12-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but--even in adult life--remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular-ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease.

  3. Mitral valve disease—morphology and mechanisms

    Science.gov (United States)

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  4. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    , most of these transcatheter mitral valve interventions are still in their early clinical or preclinical development phase. Challenges arising from the complex anatomy of the mitral valve and the interplay of the mitral apparatus with the left ventricle (LV) have contributed to a more difficult...

  5. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    system, most of these transcatheter mitral valve interventions are still in their early clinical or preclinical development phase. Challenges arising from the complex anatomy of the mitral valve and the interplay of the mitral apparatus with the left ventricle (LV) have contributed to a more difficult...

  6. Device at valves. Anordning vid ventiler

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, M.; Hedlund, P.O.

    1990-07-02

    The invention is intended to be utilized in pipes and at valves where there are risks for accumulation of oxyhydrogen gas. In or at the pipe/valve is located a body of recombining material such as platinum or other platinum metals or its alloys in order to recombine oxyhydrogen gas. (L.F.).

  7. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...

  8. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  9. Heart Valve Disease among Patients with Hyperprolactinaemia

    DEFF Research Database (Denmark)

    Steffensen, Charlotte; Maegbaek, Merete Lund; Laurberg, Peter

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  10. Mitral valve repair in acquired dextrocardia.

    Science.gov (United States)

    Elmistekawy, Elsayed; Chan, Vincent; Hynes, Mark; Mesana, Thierry

    2015-10-01

    Surgical correction of valvular heart disease in patients with dextrocardia is extremely rare. We report a surgical case of mitral valve repair in a patient with acquired dextrocardia. Successful mitral valve repair was performed through a right lateral thoracotomy. We describe our surgical strategy and summarize the literature. © The Author(s) 2014.

  11. High temperature sensors for exhaust diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Svenningstorp, Henrik

    2000-07-01

    One of the largest problems that we will have to deal with on this planet this millennium is to stop the pollution of our environment. In many of the ongoing works to reduce toxic emissions, gas sensors capable of enduring rough environments and high temperatures, would be a great tool. The different applications where sensors like this would be useful vary between everything from online measurement in the paper industry and food industry to measurement in the exhaust pipe of a car. In my project we have tested Schottky diodes and MlSiCFET sensor as gas sensors operating at high temperatures. The measurement condition in the exhaust pipe of a car is extremely tough, not only is the temperature high and the different gases quite harmful, there are also a lot of particles that can affect the sensors in an undesirable way. In my project we have been testing Schottky diodes and MlSiCFET sensors based on SiC as high temperature sensors, both in the laboratory with simulated exhaust and after a real engine. In this thesis we conclude that these sensors can work in the hostile environment of an engines exhaust. It is shown that when measuring in a gas mixture with a fixed I below one, where the I-value is controlled by the O{sub 2} concentration, a sensor with a catalytic gate metal as sensitive material respond more to the increased O{sub 2} concentration than the increased HC concentration when varying the two correspondingly. A number of different sensors have been tested in simulated exhaust towards NO{sub x}. It was shown that resistivity changes in the thin gate metal influenced the gas response. Tests have been performed where sensors were a part of a SCR system with promising results concerning NH{sub 3} sensitivity. With a working temperature of 300 deg C there is no contamination of the metal surface.

  12. Multidisciplinary optimization of a butterfly valve.

    Science.gov (United States)

    Song, Xue Guan; Wang, Lin; Baek, Seok Heum; Park, Young Chul

    2009-07-01

    A butterfly valve is a type of flow control device, typically used to regulate fluid flow. This paper proposes a new process to meet desired needs in valve design that is characterized by the complex configuration. First, the need is identified according to the valve user/company, and then the problem is defined with a characteristic function. Second, the initial model of valve is made, and then the initial analysis including fluid and/or structural analysis is carried out to predict the fluid and/or structural performance of the valve. Third, the optimization in the form of mathematical functions, which considers single or multiple objective and/or discipline, is handled. This part includes the design of computer experiment, approximation technique, topology optimization and sizing optimization. Finally, the validation experiment is conducted based on the optimum result to verify the accuracy of the optimization. An example is provided to confirm the availability of the process proposed here.

  13. Comments on compressible flow through butterfly valves

    Science.gov (United States)

    Blakenship, John G.

    In the flow analysis of process piping systems, it is desirable to treat control valves in the same way as elbow, reducers, expansions, and other pressure loss elements. In a recently reported research program, the compressible flow characteristics of butterfly valves were investigated. Fisher Controls International, Inc., manufacturer of a wide range of control valves, publishes coefficients that can be used to calculate flow characteristics for the full range of valve movement. The use is described of the manufacturer's data to calculate flow parameters as reported by the researchers who investigated compressible flow through butterfly valves. The manufacturer's data produced consistent results and can be used to predict choked flow and the pressure loss for unchoked flow.

  14. The Leipzig experience with robotic valve surgery.

    Science.gov (United States)

    Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W

    2000-01-01

    The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

  15. Airbag vent valve and system

    Science.gov (United States)

    Peterson, Leslie D. (Inventor); Zimmermann, Richard E. (Inventor)

    2001-01-01

    An energy absorbing airbag system includes one or more vent valve assemblies for controlling the release of airbag inflation gases to maintain inflation gas pressure within an airbag at a substantially constant pressure during a ride-down of an energy absorbing event. Each vent valve assembly includes a cantilever spring that is flat in an unstressed condition and that has a free end portion. The cantilever spring is secured to an exterior surface of the airbag housing and flexed to cause the second free end portion of the cantilever spring to be pressed, with a preset force, against a vent port or a closure covering the vent port to seal the vent port until inflation gas pressure within the airbag reaches a preselected value determined by the preset force whereupon the free end portion of the cantilever spring is lifted from the vent port by the inflation gases within the airbag to vent the inflation gases from within the airbag. The resilience of the cantilever spring maintains a substantially constant pressure within the airbag during a ride-down portion of an energy absorbing event by causing the cantilever spring to vent gases through the vent port whenever the pressure of the inflation gases reaches the preselected value and by causing the cantilever spring to close the vent port whenever the pressure of the inflation gases falls below the preselected value.

  16. Study on decellularized porcine aortic valve/poly (3-hydroxybutyrate-co-3-hydroxyhexanoate) hybrid heart valve in sheep model.

    Science.gov (United States)

    Wu, Song; Liu, Ying-Long; Cui, Bin; Qu, Xiang-Hua; Chen, Guo-Qiang

    2007-09-01

    To overcome shortcomings of current heart valve prostheses, novel hybrid valves were fabricated from decellularized porcine aortic valves coated with poly (3-hydroxybutyrate-co-3-hydroxyhexanoate [PHBHHx]). In the mechanical test in vitro, the biomechanical performance of hybrid valve was investigated. In an in vivo study, hybrid valve conduits were implanted in pulmonary position in sheep without cardiopulmonary bypass. Uncoated grafts were used as control. The valves were explanted and examined histologically and biochemically 16 weeks after surgery. The hybrid valve conduits maintained original shapes, were covered by a confluent layer of cells, and had less calcification than uncoated control. The mechanical test in vitro revealed that PHBHHx coating improved tensile strength. The results in vivo indicated that PHBHHx coating reduced calcification and promoted the repopulation of hybrid valve with the recipient's cells resembling native valve tissue. The hybrid valve may provide superior valve replacement with current techniques.

  17. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    Science.gov (United States)

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  18. 3D Printed Trileaflet Valve Conduits Using Biological Hydrogels and Human Valve Interstitial Cells

    Science.gov (United States)

    Duan, Bin; Kapetanovic, Edi; Hockaday, Laura A.; Butcher, Jonathan T.

    2014-01-01

    Tissue engineering has great potential to provide a functional de novo living valve replacement capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, 3D bioprinting enables deposition of cells and hydrogels into 3D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach is however constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not known how human valve cells respond to these printed environments. In this study, we develop 3D printable formulations of hybrid hydrogels based on methacrylated hyaluronic acid (Me-HA) and methacrylated gelatin (Me-Gel), and utilize them to bioprint heart valve conduits containing encapsulated human aortic valvular interstitial cells (HAVIC). Increasing Me-Gel concentration resulted in lower stiffness and higher viscosity, facilitated cell spreading, and better maintained HAVIC fibroblastic phenotype. Bioprinting accuracy was dependent upon the relative concentrations of Me-Gel and Me-HA, but when optimized enabled the fabrication of a trileaflet valve shape accurate to the original design. HAVIC encapsulated within bioprinted heart valves maintained high viability, and remodeled the initial matrix by depositing collagen and glyosaminoglycans. These findings represent the first rational design of bioprinted trileaflet valve hydrogels that regulate encapsulated human VIC behavior. The use of anatomically accurate living valve scaffolds through bioprinting may accelerate our understanding of physiological valve cell interactions and our progress towards de novo living valve replacements. PMID:24334142

  19. Quadruple valve replacement with mechanical valves: an 11-year follow-up study.

    Science.gov (United States)

    Cao, Yukun; Gu, Chunhu; Sun, Guocheng; Yu, Shiqiang; Wang, Hongbing; Yi, Dinghua

    2012-06-01

    We performed the first quadruple valve replacement with mechanical valves, combined with the correction of complex congenital heart disease on November 17, 1999. We report here the 11-year follow-up study. A 47-year-old man with subacute rheumatic endocarditis, a ventricular septal defect, and an obstruction of the right ventricular outflow tract required replacement of the aortic, mitral, tricuspid, and pulmonary valves; repair of the ventricular septal defect; and relief of the obstruction of the right ventricular outflow tract. The surgery was done on November 17, 1999, after careful systemic preparation of the patient. Warfarin therapy with a target international normalized ratio (INR) range of 1.5 to 2.0 was used. Follow-up included monitoring the INR, recording the incidences of thromboembolic and bleeding events, electrocardiography, radiography, and echocardiography evaluations. The patient's INR was maintained between 1.5 and 2.0. All 4 mechanical prosthetic heart valves worked well. He is in generally good health without any thromboembolic or bleeding complications. Long-term management is challenging for patients who have experienced quadruple valve replacement with mechanical valves; however, promising results could mean that replacement of all 4 heart valves in 1 operation is feasible in patients with quadruple valve disease, and an INR of 1.5 to 2.0 could be appropriate for Chinese patients with undergoing valve replacement with mechanical valves.

  20. Diesel exhaust exposures in port workers.

    Science.gov (United States)

    Debia, Maximilien; Neesham-Grenon, Eve; Mudaheranwa, Oliver C; Ragettli, Martina S

    2016-07-01

    Exposure to diesel engine exhaust has been linked to increased cancer risk and cardiopulmonary diseases. Diesel exhaust is a complex mixture of chemical substances, including a particulate fraction mainly composed of ultrafine particles, resulting from the incomplete combustion of fuel. Diesel trucks are known to be an important source of diesel-related air pollution, and areas with heavy truck traffic are associated with higher air pollution levels and increased public health problems. Several indicators have been proposed as surrogates for estimating exposures to diesel exhaust but very few studies have focused specifically on monitoring the ultrafine fraction through the measurement of particle number concentrations. The aim of this study is to assess occupational exposures of gate controllers at the port of Montreal, Canada, to diesel engine emissions from container trucks by measuring several surrogates through a multimetric approach which includes the assessment of both mass and number concentrations and the use of direct reading devices. A 10-day measurement campaign was carried out at two terminal checkpoints at the port of Montreal. Respirable elemental and organic carbon, PM1, PM2.5, PMresp (PM4), PM10, PMtot (inhalable fraction), particle number concentrations, particle size distributions, and gas concentrations (NO2, NO, CO) were monitored. Gate controllers were exposed to concentrations of contaminants associated with diesel engine exhaust (elemental carbon GM = 1.6 µg/m(3); GSD = 1.6) well below recommended occupational exposure limits. Average daily particle number concentrations ranged from 16,544-67,314 particles/cm³ (GM = 32,710 particles/cm³; GSD = 1.6). Significant Pearson correlation coefficients were found between daily elemental carbon, PM fractions and particle number concentrations, as well as between total carbon, PM fractions and particle number concentrations. Significant correlation coefficients were found between particle number

  1. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  2. Experimental and Potential Analysis of a Single-Valve Expander for Waste Heat Recovery of a Gasoline Engine

    Directory of Open Access Journals (Sweden)

    Wenzhi Gao

    2016-11-01

    Full Text Available In this paper, a Rankine cycle test system is established to recover exhaust energy from a 2.0 L gasoline engine. Experiments on the system’s performance are carried out under various working conditions. The experimental results indicate that the recovery power of the expander is strongly related to the load and speed of the gasoline engine. It is found that when the output power of the gasoline engine is 39.8–76.6 kW, the net power of the expander is 1.8–2.97 kW, which is equivalent to 3.9%–4.9% of the engine power. The performance simulation shows that the mass flow rate, power output, and isentropic efficiency of the piston expander are directly determined by the intake valve timing. Selecting a suitable intake valve timing can optimize the performance of the expander. The simulation results show that a 1 kW increment in power can be obtained only by selecting an optimum intake open timing. The experimental results further verify that the single-valve piston expander, because of its small dimensions, simple structure, and high speed, is appropriate, and has great potential for energy recovery of gasoline engine exhaust and has good prospects for engineering applications.

  3. 49 CFR 192.193 - Valve installation in plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve installation in plastic pipe. 192.193... Components § 192.193 Valve installation in plastic pipe. Each valve installed in plastic pipe must be designed so as to protect the plastic material against excessive torsional or shearing loads when the valve...

  4. Towards new therapies for calcific aortic valve disease

    NARCIS (Netherlands)

    Riem Vis, P.W.

    2011-01-01

    Calcific aortic valve disease (CAVD) is characterized by progressive calcification of the aortic valve cusps. The end-stage (stenosis), can lead to heart failure and death. Approximately 2-3% of adults over 65 years of age are thought to suffer from valve stenosis, requiring aortic valve

  5. 46 CFR 56.20-9 - Valve construction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Valve construction. 56.20-9 Section 56.20-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Valves § 56.20-9 Valve construction. (a) Each valve must close with a right-hand (clockwise...

  6. 14 CFR 23.1125 - Exhaust heat exchangers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Exhaust heat exchangers. 23.1125 Section 23... § 23.1125 Exhaust heat exchangers. For reciprocating engine powered airplanes the following apply: (a) Each exhaust heat exchanger must be constructed and installed to withstand the vibration, inertia, and...

  7. 40 CFR 89.416 - Raw exhaust gas flow.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Raw exhaust gas flow. 89.416 Section... Procedures § 89.416 Raw exhaust gas flow. The exhaust gas flow shall be determined by one of the methods...) Measurement of the air flow and the fuel flow by suitable metering systems (for details see SAE J244. This...

  8. 34 CFR 110.39 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Exhaustion of administrative remedies. 110.39 Section... FINANCIAL ASSISTANCE Investigation, Conciliation, and Enforcement Procedures § 110.39 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative...

  9. 38 CFR 18.550 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Exhaustion of..., Conciliation, and Enforcement Procedures § 18.550 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Act. Administrative...

  10. 45 CFR 91.50 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Exhaustion of administrative remedies. 91.50... Investigation, Conciliation, and Enforcement Procedures § 91.50 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Act...

  11. 45 CFR 90.50 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Exhaustion of administrative remedies. 90.50..., Conciliation and Enforcement Procedures § 90.50 Exhaustion of administrative remedies. (a) The agency shall provide in its regulations that a complainant may file a civil action following the exhaustion of...

  12. 12 CFR 1780.56 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Exhaustion of administrative remedies. 1780.56 Section 1780.56 Banks and Banking OFFICE OF FEDERAL HOUSING ENTERPRISE OVERSIGHT, DEPARTMENT OF HOUSING... Posthearing Proceedings § 1780.56 Exhaustion of administrative remedies. To exhaust administrative remedies as...

  13. 14 CFR 1252.410 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Exhaustion of administrative remedies. 1252..., Conciliation, and Enforcement Procedures § 1252.410 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Act...

  14. 12 CFR 1777.27 - Exhaustion and review.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Exhaustion and review. 1777.27 Section 1777.27... 1366 of the 1992 Act § 1777.27 Exhaustion and review. (a) Judicial review—(1) Review of certain actions... in section 1369D of the 1992 Act (12 U.S.C. 4623). (b) Exhaustion of administrative remedies. In...

  15. 10 CFR 4.340 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Exhaustion of administrative remedies. 4.340 Section 4.340... Act of 1975, as Amended Investigation, Conciliation, and Enforcement Procedures § 4.340 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative...

  16. 12 CFR 908.66 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Exhaustion of administrative remedies. 908.66 Section 908.66 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOUSING FINANCE BOARD ORGANIZATION... Proceedings § 908.66 Exhaustion of administrative remedies. To exhaust administrative remedies as to any issue...

  17. 45 CFR 1156.21 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Exhaustion of administrative remedies. 1156.21... Investigation, Conciliation, and Enforcement Procedures § 1156.21 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Act...

  18. 40 CFR 7.175 - Exhaustion of administrative remedy.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Exhaustion of administrative remedy. 7... Discrimination Prohibited on the Basis of Age § 7.175 Exhaustion of administrative remedy. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Age Discrimination...

  19. 41 CFR 101-8.724 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Exhaustion of administrative remedies. 101-8.724 Section 101-8.724 Public Contracts and Property Management Federal Property... Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of...

  20. 43 CFR 17.339 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Exhaustion of administrative remedies. 17... Investigation, Conciliation, and Enforcement Procedures § 17.339 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Act...

  1. 44 CFR 7.949 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Exhaustion of administrative... Investigation, Conciliation, and Enforcement Procedures § 7.949 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Act...

  2. 24 CFR 26.53 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Exhaustion of administrative remedies. 26.53 Section 26.53 Housing and Urban Development Office of the Secretary, Department of Housing... Hearings § 26.53 Exhaustion of administrative remedies. In order to fulfill the requirement of exhausting...

  3. 10 CFR 1040.89-13 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Exhaustion of administrative remedies. 1040.89-13 Section... Investigation, Conciliation and Enforcement Procedures § 1040.89-13 Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of administrative remedies under the Act...

  4. 24 CFR 146.45 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Exhaustion of administrative remedies. 146.45 Section 146.45 Housing and Urban Development Regulations Relating to Housing and Urban... Exhaustion of administrative remedies. (a) A complainant may file a civil action following the exhaustion of...

  5. 29 CFR 35.40 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Exhaustion of administrative remedies. 35.40 Section 35.40... Enforcement Procedures § 35.40 Exhaustion of administrative remedies. (a) A complainant may file a civil action under the Act following the exhaustion of administrative remedies. Administrative remedies are...

  6. [Clinical analysis of robotic mitral valve repair].

    Science.gov (United States)

    Gao, Chang-Qing; Yang, Ming; Xiao, Cang-Song; Wang, Gang; Wang, Jia-Li; Wu, Yang; Wang, Yao

    2011-07-01

    To determine the safety and efficacy of robotic mitral valve repair using da Vinci S Surgical system. Method From January 2007 to April 2011, over 400 cases of robotic cardiac surgery have been performed, in which 60 patients with isolated mitral valve insufficiency underwent robotic mitral valve repair, including 42 male and 18 female patients with a mean age of (44 ± 13) years (ranging from 14 to 70 years). Forty-eight patients were in NYHA class I-II and 12 patients in class III. Fourteen patients were concomitant with atrial fibrillation. Surgery approach was achieved through 4 right chest ports with femoral perfusion and Chitwood aortic occlusion. Antegrade cold blood cardioplegia was administered directly via chest for myocardial protection. The transesophageal echocardiography was used intraoperatively to estimate the surgical results. All patients had successful valve repair including quadrangular resections, sliding plasties and chordal replacement. There was no conversion to median sternotomy. The mean cardiopulmonary bypass and arrested heart time were (132 ± 30) min and (88 ± 22) min. One patient had hemolysis after operation, and required mitral valve replacement. Echocardiographic follow-up revealed trace to mild regurgitation in 2 patients with a mean of (16 ± 9) months. Robotic mitral valve repair is safe and efficacious in the patients with isolated mitral valve insufficiency.

  7. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  8. Contextualizing Emotional Exhaustion and Positive Emotional Display : The Signaling Effects of Supervisors' Emotional Exhaustion and Service Climate

    NARCIS (Netherlands)

    Lam, Catherine K.; Huang, Xu; Janssen, Onne; Lam, K.C.

    In this study, we investigated how supervisors' emotional exhaustion and service climate jointly influence the relationship between subordinates' emotional exhaustion and their display of positive emotions at work. Using data from frontline sales employees and their immediate supervisors in a

  9. Percutaneous management of prosthetic valve thrombosis.

    Science.gov (United States)

    Hariram, Vuppaladadhiam

    2014-01-01

    Thrombosis of a prosthetic valve is a serious complication in patients with prosthetic heart valves. Thrombolysis is the initial choice of treatment. Patients who do not respond to thrombolysis are subjected to surgery which carries a high risk. We report a case series of 5 patients with prosthetic mitral valve thrombosis who did not respond to thrombolysis and were subjected to percutaneous manipulation of the prosthetic valves successfully and improved. Five patients who were diagnosed to have prosthetic mitral valve thrombosis and failed to respond to a minimum of 36 h of thrombolysis (persistent symptoms with increased gradients, abnormal findings on fluoroscopy),were subjected to percutaneous treatment after receiving proper consent. None of them had a visible thrombus on transthoracic echocardiogram. All patients underwent transseptal puncture following which a 6F JR4 guiding catheter was passed into the left atrium. The valve leaflets were repeatedly hit gently under fluoroscopic guidance till they regained their normal mobility. Mean age was 38.8 years. Average peak and mean gradients prior to the procedure were 38 and 25 and after the procedure were 12 and 6 mm of Hg respectively. All patients had successful recovery of valve motion on fluoroscopy with normalization of gradients and complete resolution of symptoms. None of the patients had any focal neurological deficits, embolic manifestations or bleeding complications. Percutaneous manipulation of prosthetic valves in selected patients with prosthetic valve thrombosis who do not respond to thrombolytic therapy is feasible and can be used as an alternative to surgery. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  10. Transcatheter Aortic Valve Replacement: A Review Article

    Directory of Open Access Journals (Sweden)

    Juan A Siordia

    2016-06-01

    Full Text Available Transcatheter aortic valve replacement (TAVR is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive procedure and reduce common complications, such as stroke. This review article focuses on the current data on the indications, risks, benefits, and future directions of TAVR. Recently, TAVR has been considered as a standard-of-care procedure. While this technique is used frequently in high-risk surgical candidates, studies have been focusing on the application of this method for younger patients with lower surgical risk. Moreover, several studies have proposed promising results regarding the use of valve-in-valve technique or the procedure in which the valve is placed within a previously implemented bioprosthetic valve. However, ischemic strokes and paravalvular leak remain a matter of debate in these surgeries. New methods and devices have been developed to reduce the incidence of post-procedural stroke. While the third generation of TAVR valves (i.e., Edwards Sapien 3 and Medtronic Evolut R addresses the issue of paravalvular leak structurally, results on their efficacy in reducing the risk of paravalvular leak are yet to be obtained. Furthermore, TAVR enters the field of hybrid methods in the treatment of cardiac issues via both surgical and catheter-based approaches. Finally, while TAVR is primarily performed on cases with aortic stenosis, new valves and methods have been proposed regarding the application of this technique in aortic regurgitation, as well as other aortic pathologies. TAVR is a suitable therapeutic approach for the treatment of aortic stenosis in high-risk patients. Considering the promising results in the current patient population

  11. Exhaust Nozzle Plume and Shock Wave Interaction

    Science.gov (United States)

    Castner, Raymond S.; Elmiligui, Alaa; Cliff, Susan

    2013-01-01

    Fundamental research for sonic boom reduction is needed to quantify the interaction of shock waves generated from the aircraft wing or tail surfaces with the exhaust plume. Both the nozzle exhaust plume shape and the tail shock shape may be affected by an interaction that may alter the vehicle sonic boom signature. The plume and shock interaction was studied using Computational Fluid Dynamics simulation on two types of convergent-divergent nozzles and a simple wedge shock generator. The nozzle plume effects on the lower wedge compression region are evaluated for two- and three-dimensional nozzle plumes. Results show that the compression from the wedge deflects the nozzle plume and shocks form on the deflected lower plume boundary. The sonic boom pressure signature of the wedge is modified by the presence of the plume, and the computational predictions show significant (8 to 15 percent) changes in shock amplitude.

  12. Concept of Heat Recovery from Exhaust Gases

    Science.gov (United States)

    Bukowska, Maria; Nowak, Krzysztof; Proszak-Miąsik, Danuta; Rabczak, Sławomir

    2017-10-01

    The theme of the article is to determine the possibility of waste heat recovery and use it to prepare hot water. The scope includes a description of the existing sample of coal-fired boiler plant, the analysis of working condition and heat recovery proposals. For this purpose, a series of calculations necessary to identify the energy effect of exhaust temperature decreasing and transferring recovery heat to hot water processing. Heat recover solutions from the exhaust gases channel between boiler and chimney section were proposed. Estimation for the cost-effectiveness of such a solution was made. All calculations and analysis were performed for typical Polish conditions, for coal-fired boiler plant. Typicality of this solution is manifested by the volatility of the load during the year, due to distribution of heat for heating and hot water, determining the load variation during the day. Analysed system of three boilers in case of load variation allows to operational flexibility and adaptation of the boilers load to the current heat demand. This adaptation requires changes in the operating conditions of boilers and in particular assurance of properly conditions for the combustion of fuel. These conditions have an impact on the existing thermal loss and the overall efficiency of the boiler plant. On the boiler plant efficiency affects particularly exhaust gas temperature and the excess air factor. Increasing the efficiency of boilers plant is possible to reach by following actions: limiting the excess air factor in coal combustion process in boilers and using an additional heat exchanger in the exhaust gas channel outside of boilers (economizer) intended to preheat the hot water.

  13. Validation of Karolinska Exhaustion Scale: psychometric properties of a measure of exhaustion syndrome.

    Science.gov (United States)

    Saboonchi, Fredrik; Perski, Aleksander; Grossi, Giorgio

    2013-12-01

    The syndrome of exhaustion is currently a medical diagnosis in Sweden. The description of the syndrome largely corresponds to the suggested core component of burnout, that is exhaustion. Karolinska Exhaustion Scale (KES) has been constructed to provide specific assessment of exhaustion in clinical and research settings. The purpose of the present study was to examine the psychometric properties of this scale in its original and revised versions by examining the factorial structure and measures of convergent and discriminant validity. Data gathered from two independent samples (n1 = 358 & n2 = 403) consisting of patients diagnosed with 'reaction to severe stress, and adjustment disorder' were subjected to confirmatory factor analysis. The study's instruments were Karolinska Exhaustion Scale and Shirom Melam Burnout Measure. Correlation analyses were employed to follow up the established factorial structure of the scale. The study was ethically approved by Karolinska Institute regional ethic committee. The findings demonstrated adequate fit of the data to the measurement model provided by the revised version of KES Limitations: The main limitation of the present study is the lack of a gold standard of exhaustion for direct comparison with KES. (KES-26) and partially supported convergent validity and discriminant validity of the scale. The demonstrated psychometric properties of KES-26 indicate sound construct validity for this scale encouraging use of this scale in assessment of exhaustion. The factorial structure of KES-26 may also be used to provide information concerning possible different clinical profiles. © 2012 The Authors Scandinavian Journal of Caring Sciences © 2012 Nordic College of Caring Science.

  14. Computed Flow Through An Artificial Heart Valve

    Science.gov (United States)

    Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

  15. Sensitivity study of a valve recession model

    OpenAIRE

    Vera-Cardenas, E.E.; Lewis, R; Slatter, T.

    2017-01-01

    The aim of this work was to carry out a sensitivity\\ud analysis of a valve recession model. \\ud For the sensitivity study, the effects of the param\\ud eters on the valve recession mode\\ud l were \\ud investigated, for both, light duty and heavy duty \\ud engines. It was seen that for light duty \\ud engines, the impact component parameters had the gr\\ud eatest effect on valve recession and \\ud for heavy duty engines the sliding wear component p\\ud arameters have an increasing con-\\ud tribution t...

  16. PUMP ARRANGEMENT COMPRISING A SAFETY VALVE ARRANGEMENT

    OpenAIRE

    Richter, Martin; Wackerle, Martin

    2014-01-01

    A pump arrangement comprises a microfluidic pump (20) having a pump inlet (22) and a pump outlet (24), which is configured to pump a fluid from the pump inlet to the pump outlet, wherein the pump inlet (22) and an inlet (46) of the pump arrangement are fluidically connected. The pump arrangement further comprises a safety valve arrangement having first safety valve (40), the first safety valve (40) being arranged between the pump outlet (24) and an outlet (48) of the pump arrangement and comp...

  17. Rotary Valve FY 2016 Highlights

    Energy Technology Data Exchange (ETDEWEB)

    Fitsos, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-07

    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  18. Conical seat shut off valve

    Science.gov (United States)

    Farner, Bruce R. (Inventor)

    2012-01-01

    A valve includes a housing defining a bore having an inlet and extending along a longitudinal axis. A head is attached to the housing and defines a head passage having an outlet. A piston is disposed within the bore and includes a piston passage extending through the piston along the longitudinal axis. The piston is moveable between a closed position in which a sealing end of the piston abuts a seat of the head to close fluid communication through the piston passage and an open position in which the sealing end of the piston is axially spaced along the longitudinal axis from the seat of the head to permit fluid communication through the piston passage between the inlet and the outlet. The housing defines an equalizing chamber in fluid communication with the head passage for damping movement of the piston.

  19. Valve Corporation: Composing Internal Markets

    Directory of Open Access Journals (Sweden)

    Todd R. Zenger

    2015-07-01

    Full Text Available Discussions of the Valve Corporation are always enlightening. The skeptic wonders how much is rhetoric and recruiting ploy and how much is real. Is there clear evidence that this organizational design actually works – that it is efficient in this setting? While revenues per employee are quite remarkable, cause and effect are unclear. Is “boss-less-ness” the cause of high sales per employee or simply the result of high sales per employee, fueled from earlier success? The same question could be asked of Google’s unusual organizational approach. Is Google’s success the result of its extensive autonomy granted to employees, or is its past success the enabling cause of such autonomy? Such questions, of course, are empirically unanswerable here. I therefore set them aside and assume this organizational specimen is efficient – well-suited to its environment – and proceed with further commentary.

  20. In vitro balloon dilatation of mitral valve stenosis: the importance of subvalvar involvement as a cause of mitral valve insufficiency

    NARCIS (Netherlands)

    Sadee, A. S.; Becker, A. E.

    1991-01-01

    To investigate the mechanism that increases the orifice area of the mitral valve during balloon dilatation 43 surgically excised intact rheumatic mitral valves were studied. The main pathological features were (a) fibrosis of mitral valve leaflets and commissures (10 valves); (b) fibrosis with

  1. 46 CFR 153.361 - Arrangements for removal of valves from venting systems having multiple relief valves.

    Science.gov (United States)

    2010-10-01

    ... having multiple relief valves. 153.361 Section 153.361 Shipping COAST GUARD, DEPARTMENT OF HOMELAND... removal of valves from venting systems having multiple relief valves. A venting system having multiple... arranged so that cargo vapor will not escape through the opening left after a valve has been removed. ...

  2. Transcatheter aortic valve implantation with balloonexpandable valve: early experience from China

    Directory of Open Access Journals (Sweden)

    Qingsheng Lu

    2015-08-01

    Full Text Available Abstract Objective: The aim of the current study was to evaluate the early experience of the application of transcatheter aortic valve implantation with the balloon-expandable system in China. The transcatheter aortic valve implantation technology has been widely used for patients with inoperable severe aortic stenosis in the developed world. The application of transcatheter aortic valve implantation is still in the early stages of testing in China, particularly for the balloon-expandable valve procedure. Methods: This was a retrospective study. All patients undergoing transcatheter aortic valve implantation with balloon-expandable system in our hospital between 2011 and 2014 were included. Edwards SAPIEN XT Transcatheter Heart Valve was used. The improvement of valve and heart function was evaluated as well as 30-day mortality and major complications according to the VARC-2 definition. Results: A total of 10 transcatheter aortic valve implantation procedures with the balloon-expandable system were performed in our hospital, of which 9 were transfemoral and 1 was transapical. The median age was 76 years, and the median STS score and Logistic EuroSCORE (% were 8.9 and 16.2. The implantation was successfully conducted in all patients, only 2 patients had mild paravalvular leak. There was no second valve implantation. Moreover, no 30-day mortality or complications was reported. Following the transcatheter aortic valve implantation procedure, the heart and valve functions had improved significantly. During the follow-up period of 3-34 months, one patient died of lung cancer 13 months after the operation. Conclusion: This early experience has provided preliminary evidence for the safety and efficacy of transcatheter aortic valve implantation procedure with the balloon-expandable system in the developing world with an increasing aging population.

  3. Osteoprotegerin inhibits aortic valve calcification and preserves valve function in hypercholesterolemic mice.

    Directory of Open Access Journals (Sweden)

    Robert M Weiss

    Full Text Available There are no rigorously confirmed effective medical therapies for calcific aortic stenosis. Hypercholesterolemic Ldlr (-/- Apob (100/100 mice develop calcific aortic stenosis and valvular cardiomyopathy in old age. Osteoprotegerin (OPG modulates calcification in bone and blood vessels, but its effect on valve calcification and valve function is not known.To determine the impact of pharmacologic treatment with OPG upon aortic valve calcification and valve function in aortic stenosis-prone hypercholesterolemic Ldlr (-/- Apob (100/100 mice.Young Ldlr (-/- Apob (100/100 mice (age 2 months were fed a Western diet and received exogenous OPG or vehicle (N = 12 each 3 times per week, until age 8 months. After echocardiographic evaluation of valve function, the aortic valve was evaluated histologically. Older Ldlr (-/- Apob (100/100 mice were fed a Western diet beginning at age 2 months. OPG or vehicle (N = 12 each was administered from 6 to 12 months of age, followed by echocardiographic evaluation of valve function, followed by histologic evaluation.In Young Ldlr (-/- Apob (100/100 mice, OPG significantly attenuated osteogenic transformation in the aortic valve, but did not affect lipid accumulation. In Older Ldlr (-/- Apob (100/100 mice, OPG attenuated accumulation of the osteoblast-specific matrix protein osteocalcin by ∼80%, and attenuated aortic valve calcification by ∼ 70%. OPG also attenuated impairment of aortic valve function.OPG attenuates pro-calcific processes in the aortic valve, and protects against impairment of aortic valve function in hypercholesterolemic aortic stenosis-prone Ldlr (-/- Apob (100/100 mice.

  4. Computational Fluid Dynamics Analysis of Butterfly Valve Performance Factors

    OpenAIRE

    Del Toro, Adam

    2012-01-01

    Butterfly valves are commonly used in industrial applications to control the internal flow of both compressible and incompressible fluids. A butterfly valve typically consists of a metal disc formed around a central shaft, which acts as its axis of rotation. As the valve's opening angle is increased from 0 degrees (fully closed) to 90 degrees (fully open), fluid is able to more readily flow past the valve. Characterizing a valve's performance factors, such as pressure drop, hydrodynamic torqu...

  5. The 3 S's of the Sapien balloon expandable valve.

    Science.gov (United States)

    Kornowski, Ran

    2016-09-01

    The Sapien 3 (S3) balloon expandable aortic valve equipped with an outer skirt to minimize paravalvular leakage (PVL) was built upon the predecessor Sapien XT (SXT) valve. There is scant comparative data of transcatheter aortic valve replacement using S3 versus SXT valve. The study shows that S3 valve is associated with reduced PVL rate compared with SXT, which is an important clinical advantage. © 2016 Wiley Periodicals, Inc.

  6. Exhaust gas recirculation in a homogeneous charge compression ignition engine

    Science.gov (United States)

    Duffy, Kevin P [Metamora, IL; Kieser, Andrew J [Morton, IL; Rodman, Anthony [Chillicothe, IL; Liechty, Michael P [Chillicothe, IL; Hergart, Carl-Anders [Peoria, IL; Hardy, William L [Peoria, IL

    2008-05-27

    A homogeneous charge compression ignition engine operates by injecting liquid fuel directly in a combustion chamber, and mixing the fuel with recirculated exhaust and fresh air through an auto ignition condition of the fuel. The engine includes at least one turbocharger for extracting energy from the engine exhaust and using that energy to boost intake pressure of recirculated exhaust gas and fresh air. Elevated proportions of exhaust gas recirculated to the engine are attained by throttling the fresh air inlet supply. These elevated exhaust gas recirculation rates allow the HCCI engine to be operated at higher speeds and loads rendering the HCCI engine a more viable alternative to a conventional diesel engine.

  7. T-cell exhaustion in the tumor microenvironment

    Science.gov (United States)

    Jiang, Y; Li, Y; Zhu, B

    2015-01-01

    T-cell exhaustion was originally identified during chronic infection in mice, and was subsequently observed in humans with cancer. The exhausted T cells in the tumor microenvironment show overexpressed inhibitory receptors, decreased effector cytokine production and cytolytic activity, leading to the failure of cancer elimination. Restoring exhausted T cells represents an inspiring strategy for cancer treatment, which has yielded promising results and become a significant breakthrough in the cancer immunotherapy. In this review, we overview the updated understanding on the exhausted T cells in cancer and their potential regulatory mechanisms and discuss current therapeutic interventions targeting exhausted T cells in clinical trials. PMID:26086965

  8. Large scale steam valve test: Performance testing of large butterfly valves and full scale high flowrate steam testing

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, J.B.; Robbins, G.E.; Roselius, D.G. [and others

    1995-05-01

    This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned valves operated satisfactorily under high flow conditions.

  9. A Hybrid Double Access for Transcatheter Mitral Valve-In-Valve Implantation.

    Science.gov (United States)

    Pagnotta, Paolo; Mennuni, Marco G; Ferrante, Giuseppe; Ornaghi, Diego; Bragato, Renato; Cappai, Antioco; Presbitero, Patrizia

    2015-06-01

    We present a case of hybrid mitral valve-in valve implantation. The planned transapical approach failed due to the inability to cross the degenerated stenotic mitral bioprosthesis. An alternative strategy was performed: first, an anterograde crossing of mitral stenosis, and then, a guidewire externalization through the apex by using a snare. To our knowledge, this is the first described case of double approach mitral valve-in valve implantation. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. In vitro evaluation of the iValve: a novel hands-free speech valve.

    Science.gov (United States)

    van der Houwen, Eduard B; van Kalkeren, Tjouwke A; Burgerhof, Johannes G M; van der Laan, Bernard F A M; Verkerke, Gijsbertus J

    2011-12-01

    We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops. This method makes long sentences or pauses difficult. The novel iValve is designed to allow almost natural speech, with mid-sentence pausing and whispering. The inhalation closing flows and exhalation opening pressures of 6 iValve prototype versions at different settings were compared with physiological values. The airflow resistance at inhalation was compared to physiological values and to commercial valve values. The iValve prototypes showed flow and pressure ranges in concordance with the physiological values in the literature. The airflow resistance in the breathing mode was within the physiological airflow resistance range, yet above the values from the two commercial valves. The resistance in the speaking mode was above the physiological airflow resistance range. In vitro tests show that the iValve versions can be selected and adjusted to operate within the physiological range. The airflow resistance in the breathing mode is good. In speaking mode, inhalation should, and can, be decreased. The iValve should offer the patient a more intuitively useable alternative with more dynamic speech. Its low cost allows disposability and wider use.

  11. Full metal jacket: transfemoral aortic valve implantation for regurgitant valve after endovascular aortic repair†.

    Science.gov (United States)

    Tanyeli, Omer; Dereli, Yuksel; Gormus, Niyazi; Duzenli, Mehmet Akif

    2017-07-25

    Transfemoral aortic valve implantation has become an almost routine interventional procedure for severe aortic stenosis in high-risk patients. Over time an increased number of experiences has led to unusual procedures. In this report, we present a successful valve-in-valve transfemoral aortic valve implantation in a patient with aortic regurgitation, who previously had debranching and thoracic endovascular aortic repair operations. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  13. Boosting devices with integral features for recirculating exhaust gas

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ko-Jen

    2015-12-22

    According to one embodiment of the invention, a turbine housing includes a turbine inlet in fluid communication with a turbine volute configured to house a turbine wheel, the turbine inlet configured to direct an exhaust gas flow from an engine to the turbine wheel. The turbine housing also includes a turbine outlet in fluid communication with the turbine volute, the turbine outlet configured to direct the exhaust gas flow to an exhaust gas conduit and a first exhaust gas recirculation supply port located on and in fluid communication with the turbine outlet, the first exhaust gas recirculation supply port being configured to direct a portion of the exhaust gas flow to an exhaust gas recirculation supply conduit.

  14. Engine with exhaust gas recirculation system and variable geometry turbocharger

    Science.gov (United States)

    Keating, Edward J.

    2015-11-03

    An engine assembly includes an intake assembly, an internal combustion engine defining a plurality of cylinders and configured to combust a fuel and produce exhaust gas, and an exhaust assembly in fluid communication with a first subset of the plurality of cylinders. Each of the plurality of cylinders are provided in fluid communication with the intake assembly. The exhaust assembly is provided in fluid communication with a first subset of the plurality of cylinders, and a dedicated exhaust gas recirculation system in fluid communication with both a second subset of the plurality of cylinders and with the intake assembly. The dedicated exhaust gas recirculation system is configured to route all of the exhaust gas from the second subset of the plurality of cylinders to the intake assembly. Finally, the engine assembly includes a turbocharger having a variable geometry turbine in fluid communication with the exhaust assembly.

  15. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two low-mass, linear throttling, high-efficiency, leak-proof cryogenic valves of diameters 1/2" and 4" will be built and tested. Based upon cryogenically-proven...

  16. Fluid-solid modeling of lymphatic valves

    Science.gov (United States)

    Caulk, Alexander; Ballard, Matthew; Nepiyushchikh, Zhanna; Dixon, Brandon; Alexeev, Alexander

    2015-11-01

    The lymphatic system performs important physiological functions such as the return of interstitial fluid to the bloodstream to maintain tissue fluid balance, as well as the transport of immune cells in the body. It utilizes contractile lymphatic vessels, which contain valves that open and close to allow flow in only one direction, to directionally pump lymph against a pressure gradient. We develop a fluid-solid model of geometrically representative lymphatic valves. Our model uses a hybrid lattice-Boltzmann lattice spring method to capture fluid-solid interactions with two-way coupling between a viscous fluid and lymphatic valves in a lymphatic vessel. We use this model to investigate the opening and closing of lymphatic valves, and its effect on lymphatic pumping. This helps to broaden our understanding of the fluid dynamics of the lymphatic system.

  17. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two cryogenic flow-control valves of diameters 1/2" and 2" will be built and tested. Based on cryogenically-proven Venturi Off-Set Technology (VOST) they have no...

  18. Modeling study of the ABS relay valve

    Science.gov (United States)

    Lei, Ming; Lin, Min; Guo, Bin; Luo, Zai; Xu, Weidong

    2011-05-01

    The ABS (anti-lock braking system) relay valve is the key component of anti-lock braking system in most commercial vehicles such as trucks, tractor-trailers, etc. In this paper, structure of ABS relay valve and its work theory were analyzed. Then a mathematical model of ABS relay valve, which was investigated by dividing into electronic part, magnetic part, pneumatic part and mechanical part, was set up. The displacement of spools and the response of pressure increasing, holding, releasing of ABS relay valve were simulated and analyzed under conditions of control pressure 500 KPa, braking pressure 600 KPa, atmospheric pressure 100 KPa and air temperature 310 K. Thisarticle provides reliable theory for improving the performance and efficiency of anti-lock braking system of vehicles.

  19. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  20. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric actuators constructed with the "smart material" PZT offer many potential advantages for use in NASA cryo-valve missions relative to conventional...

  1. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cryogenic flow-control valve based on Venturi-Offset Technology (VOST) will be designed and modeled. VOST provides precise linear flow control within a...

  2. Heart Valve Surgery Recovery and Follow Up

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Heart Valve Surgery Recovery and Follow Up Updated:Sep 14,2016 ... resources from Adam Pick's blog: Traveling Timeline After Heart Surgery 5 Things to Do While Your Heart Mends ( ...

  3. Posterior Urethral Valves with Severe Unilateral Vesicoureteral ...

    African Journals Online (AJOL)

    2004-08-10

    Aug 10, 2004 ... urinary catheter drainage, with no pedal oedema. There ... In patients with posterior urethral valves (PUV), severe unilateral vesicoureteral reflux (VUR) is one ... evaluation of urinary tract infection (UTI), voiding dysfunction, or ...

  4. Automatic balancing valves in distribution networks today

    Energy Technology Data Exchange (ETDEWEB)

    Golestan, F. [Flow Design, Inc., Dallas, TX (United States)

    1996-12-31

    Automatic flow-limiting (self-actuated) valves have been in the heating, ventilating, and air-conditioning (HVAC) market for some time now. Their principle of operation is based on fluid momentum and Bernoulli`s theorem. Basically, they absorb pressure to keep the flow rate constant. The general operation and their flow characteristics are described in the 1992 ASHRAE Handbook--Systems and Equipment, chapter 43 (ASHRAE 1992). The application and interaction of these valves with other system components, when installed in hydronic distribution networks, are outlined in this presentation. A simple, multilevel piping network is analyzed. The network consists of a pump, connecting piping, an automatic temperature control valve (ATC), a coil, and balancing valves.

  5. Novel passive normally closed microfluidic valve

    CSIR Research Space (South Africa)

    Land, K

    2009-09-01

    Full Text Available -8 lithography and replication molding processes. It was successfully implemented, and initial results show the relationship between the applied pressure and flow rate. In addition to being used as a toggle valve, this design also allows...

  6. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. All rights reserved.

  7. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cylindrical, low-mass, high-efficiency, leak-proof cryogenic valve will be designed using composites and exotic metals. Based upon cryogenically-proven Venturi...

  8. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. ...

  9. A Hybrid Tissue-Engineered Heart Valve

    National Research Council Canada - National Science Library

    Alavi, S Hamed; Kheradvar, Arash

    2015-01-01

    This study describes the efforts to develop and test the first hybrid tissue-engineered heart valve whose leaflets are composed of an extra-thin superelastic Nitinol mesh tightly enclosed by uniform...

  10. Basis of valve operator selection for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H. S.; Lee, D. J.; See, J. K.; Park, C. K.; Choi, B. S

    2000-05-01

    SMART, an integral reactor with enhanced safety and operability, is under development for use of the nuclear energy. The valve operator of SMART system were selected through the data survey and technical review of potential valve fabrication vendors, and it will provide the establishment and optimization of the basic system design of SMART. In order to establish and optimize the basic system design of SMART, the basis of selection for the valve operator type were provided based on the basic design requirements. The basis of valve operator selection for SMART will be used as a basic technical data for the SMART basic and detail design and a fundamental material for the new reactor development in the future.

  11. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we report a case of an antenatal female in first trimester with aortic prosthetic valve thrombosis (PVT), who was successfully ...

  12. Frostless heat pump having thermal expansion valves

    Science.gov (United States)

    Chen, Fang C [Knoxville, TN; Mei, Viung C [Oak Ridge, TN

    2002-10-22

    A heat pump system having an operable relationship for transferring heat between an exterior atmosphere and an interior atmosphere via a fluid refrigerant and further having a compressor, an interior heat exchanger, an exterior heat exchanger, a heat pump reversing valve, an accumulator, a thermal expansion valve having a remote sensing bulb disposed in heat transferable contact with the refrigerant piping section between said accumulator and said reversing valve, an outdoor temperature sensor, and a first means for heating said remote sensing bulb in response to said outdoor temperature sensor thereby opening said thermal expansion valve to raise suction pressure in order to mitigate defrosting of said exterior heat exchanger wherein said heat pump continues to operate in a heating mode.

  13. Infective endocarditis following transcatheter aortic valve replacement-

    DEFF Research Database (Denmark)

    Loh, Poay Huan; Bundgaard, Henning; S�ndergaard, Lars

    2013-01-01

    Transcatheter aortic valve replacement (TAVR) can improve the symptoms and prognosis of patients with severe aortic stenosis who, due to a high expected operative risk, would not have otherwise been treated surgically. If these patients develop prosthetic valve endocarditis, their presentations m...... treated medically, discuss the challenges in the diagnosis and management of such patients, and review available literature on the incidence and outcome of the condition. © 2012 Wiley Periodicals, Inc....

  14. Numerical simulation of mitral valve function

    OpenAIRE

    Lau, K. D.

    2012-01-01

    In the mammalian heart there are four heart valves (HV), of which the largest is the mitral valve (MV). Key components in the circulatory system, correct HV function is vital to cardiovascular health. A tethered and asymmetric structure, the MV regulates unidirectional flow between the left atrium and left ventricle. MVfunction is divided between systole/closure, where theMVis required to sustain a pressure load ~120 mmHg whilst minimising flow reversal, and diastole/opening in wh...

  15. Native valve Escherichia coli endocarditis following urosepsis

    Directory of Open Access Journals (Sweden)

    D Rangarajan

    2013-01-01

    Full Text Available Gram-negative organisms are a rare cause of infective endocarditis. Escherichia coli, the most common cause of urinary tract infection and gram-negative septicemia involves endocardium rarely. In this case report, we describe infection of native mitral valve by E. coli following septicemia of urinary tract origin in a diabetic male; subsequently, he required prosthetic tissue valve replacement indicated by persistent sepsis and congestive cardiac failure.

  16. Native valve Escherichia coli endocarditis following urosepsis

    OpenAIRE

    Rangarajan, D.; Ramakrishnan, S.; Patro, K. C.; Devaraj, S.; Krishnamurthy, V.; Kothari, Y.; Satyaki, N.

    2013-01-01

    Gram-negative organisms are a rare cause of infective endocarditis. Escherichia coli, the most common cause of urinary tract infection and gram-negative septicemia involves endocardium rarely. In this case report, we describe infection of native mitral valve by E. coli following septicemia of urinary tract origin in a diabetic male; subsequently, he required prosthetic tissue valve replacement indicated by persistent sepsis and congestive cardiac failure.

  17. Potential problems will drillstring safety valves

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    In the paper titled ``New generation drill string safety valves,`` presented at the IADC Well Control Conference for Europe, Aberdeen, May 22--24, 1996, documented limitations of presently available drillstring safety valves commonly used as kelly valves and stabbing valves were presented, and industry efforts to develop solutions to these problems were described. Authors of the paper are B.A. Tarr and R.A. Sukup (Mobil E and P Technology Center, Dallas), Dr. R. Luy (ITE, Clausthal, Germany), G. Rabby (Hi-Kalibre, Edmonton, Alberta) and J. Mertsch (ITAG, Celle, Germany). In 1995, the Task Group developed a draft of a new spec, and a DSSV testing program was initiated as a joint industry project, with the Gas Research Institute (GRI) as the major sponsor. Two manufacturers, Hi-Kalibre and ITAG, agreed to build new valves for the testing program. Hi-Kalibre, Edmonton, Alberta, supplied an already-commercial twin floating ball valve for November 1995 testing. This product is being used by Tesco in its portable top drive system. ITAG of Germany supplied a radically improved DSSV design, which was tested in December, and was to be retested in May following modifications.

  18. Europa Propulsion Valve Seat Material Testing

    Science.gov (United States)

    Addona, Brad M.

    2017-01-01

    The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.

  19. A Hybrid Tissue-Engineered Heart Valve.

    Science.gov (United States)

    Alavi, S Hamed; Kheradvar, Arash

    2015-06-01

    This study describes the efforts to develop and test the first hybrid tissue-engineered heart valve whose leaflets are composed of an extra-thin superelastic Nitinol mesh tightly enclosed by uniform tissue layers composed of multiple cell types. The trileaflet Nitinol mesh scaffolds underwent three-dimensional cell culture with smooth muscle and fibroblast/myofibroblast cells enclosing the mesh, which were finally covered by an endothelial cell layer. Quantitative and qualitative assays were performed to analyze the microstructure of the tissues. A tissue composition almost similar to that of natural heart valve leaflets was observed. The function of the valves and their Nitinol scaffolds were tested in a heart flow simulator that confirmed the trileaflet valves open and close robustly under physiologic flow conditions with an effective orifice area of 75%. The tissue-metal attachment of the leaflets once exposed to physiologic flow rates was tested and approved. Our preliminary results indicate that the novel hybrid approach with nondegradable scaffold for engineering heart valves is viable and may address the issues associated with current tissue-engineered valves developed with degradable scaffolds. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Experimental study of asymmetric heart valve prototype

    Science.gov (United States)

    Vukicevic, M.; Fortini, S.; Querzoli, G.; Cenedese, A.; Pedrizzetti, G.

    2011-11-01

    The mechanical heart valves (MHVs) are extremely important medical devices, commonly used for diseased heart valves replacement. Despite the long term of use and constant design refinement, the MHVs are very far from ideal and their performance is very diverse from that of the native ones. It has been approved that small variations in geometry of valvular leaflets influence the significant change in the intraventricular vortical flow, known as one of the most important factors for the overall functionality of the heart. We have experimentally examined the home-made heart valve prototypes, exclusively modeled for the mitral valve replacement. The performance and energetic properties of the prototypes have been compared with those in the presence of standard MHVs. The analysis was based on the testing of intraventricular fluid dynamics, usually missing criteria for the quality of the valve performance. It has been shown that the asymmetric prototype, with unequal leaflets and D-shaped orifice produces flow patterns and energetic properties close to those found in the healthy subjects. Thus, the break of symmetry in the standard bi-leaflet MHV prosthesis, at least from the fluid dynamics point of view, is worthwhile to be considered for the design of MHVs for the mitral valve replacement.

  1. Combined mitral and tricuspid valve repair in rheumatic valve disease: fewer reoperations with prosthetic ring annuloplasty.

    Science.gov (United States)

    Bernal, José M; Pontón, Alejandro; Diaz, Begoña; Llorca, Javier; García, Iván; Sarralde, J Aurelio; Gutiérrez-Morlote, Jesús; Pérez-Negueruela, Carolina; Revuelta, José M

    2010-05-04

    We examined predictors of early and very long-term outcome after combined mitral and tricuspid valve repair for rheumatic disease. Between 1974 and 2002, 153 consecutive patients (mean age, 46.0+/-13.2 years) underwent combined mitral and tricuspid valve repair for rheumatic disease. Mitral disease was predominantly stenosis (82.3%); 100% of patients had organic tricuspid valve disease, predominantly with regurgitation (53.6%) or some degree of tricuspid stenosis (46.4%). Mitral repair included commissurotomy in 132 patients (86.3%) associated with a flexible annuloplasty in 108. Tricuspid valve repair included flexible annuloplasty in 68 patients (44.4%) and suture annuloplasty in 20 patients (13.1%) combined with tricuspid commissurotomy in 62 patients (42.5%). Thirty-day mortality was 5.9%. Late mortality was 60.1%. The median follow-up was 15.8 years (interquartile range, 6 to 19 years). Follow-up was 97.9% complete. Age>65 years was the only predictor of late mortality. Kaplan-Meier survival probability was 74.4% at 10 years and 57.0% at 15 years. Sixty-three patients required valve reoperation (mitral valve, 59; tricuspid valve, 38). Predictors of valve reoperations were either mitral or tricuspid commissurotomy without associated prosthetic ring annuloplasty. At 20 years, Kaplan-Meier freedom from reoperation was 48.5+/-5.1%. Combined mitral and tricuspid valve repair in rheumatic disease showed satisfactory early results. Long-term results were poor because of high mortality and a high number of valve-related reoperations. The use of prosthetic ring annuloplasty was significantly associated with a reduced incidence of both mitral and tricuspid valve reoperations.

  2. Comparative Matched Outcome of Evolut-R vs CoreValve Transcatheter Aortic Valve Implantation.

    Science.gov (United States)

    Landes, Uri; Bental, Tamir; Barsheshet, Alon; Assali, Abid; Vaknin Assa, Hana; Levi, Amos; Orvin, Katia; Kornowski, Ran

    2017-02-01

    The Evolut-R (Medtronic, Inc) is a transcatheter aortic valve implantation (TAVI) system that was built on the well-established foundation of Medtronic's CoreValve device platform. Although already in extensive clinical utilization, it is unknown if the Evolut-R improves TAVI outcomes. Herein, we compared TAVI outcomes of the Evolut-R and CoreValve devices. A propensity score 1:1 matching was conducted on 358 Evolut-R patients (n = 75) and CoreValve patients (n = 283). Thirty-day outcomes were compared using Valve Academic Research Consortium (VARC)-2 criteria. A combined 30-day endpoint including all-cause death, stroke, major vascular complication, major bleeding, implantation failure, paravalvular leak (PVL) ≥ moderate, and new pacemaker implantation was also tested. The final study group included 146 patients (73 Evolut-R; 73 CoreValve). Post matching, baseline characteristics were similar between the two groups. Mean patient age was 82 ± 6 years, mean STS score was 5.2 ± 3.8, 72% were female, and 17% were deemed frail. Implantation success reached 99% with Evolut-R and 94% with CoreValve (P=.10). Both groups had low periprocedural stroke/myocardial infarction/mortality rates and there was also no difference in 30-day vascular complications (P=.18), bleeding (P=.37), PVL (P=.24), and new pacemaker (P=.14). The combined outcome rate was 24% with Evolut-R and 37% with CoreValve (P=.10). This study indicates that the efficacy and safety of the self-expandable second-generation Evolut-R transcatheter valve is at least comparable with the first-generation CoreValve. The observed improved performance in correct positioning of a single valve and the numerically lower chance to suffer a combined TAVI endpoint needs further investigation.

  3. Response of selected plant and insect species to simulated SRM exhaust mixtures and to exhaust components from SRM fuels

    Science.gov (United States)

    Heck, W. W.

    1980-01-01

    The possible biologic effects of exhaust products from solid rocket motor (SRM) burns associated with the space shuttle are examined. The major components of the exhaust that might have an adverse effect on vegetation, HCl and Al2O3 are studied. Dose response curves for native and cultivated plants and selected insects exposed to simulated exhaust and component chemicals from SRM exhaust are presented. A system for dispensing and monitoring component chemicals of SRM exhaust (HCl and Al2O3) and a system for exposing test plants to simulated SRM exhaust (controlled fuel burns) are described. The effects of HCl, Al2O3, and mixtures of the two on the honeybee, the corn earworm, and the common lacewing and the effects of simulated exhaust on the honeybee are discussed.

  4. Electromechanically Actuated Valve for Controlling Flow Rate

    Science.gov (United States)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces

  5. Matched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis: Insights From the Valve-in-Valve International Data Registry (VIVID).

    Science.gov (United States)

    Alnasser, Sami; Cheema, Asim N; Simonato, Matheus; Barbanti, Marco; Edwards, Jeremy; Kornowski, Ran; Horlick, Eric; Wijeysundera, Harindra C; Testa, Luca; Bedogni, Francesco; Amrane, Hafid; Walther, Thomas; Pelletier, Marc; Latib, Azeem; Laborde, Jean-Claude; Hildick-Smith, David; Kim, Won-Keun; Tchetche, Didier; Agrifoglio, Marco; Sinning, Jan-Malte; van Boven, Ad J; Kefer, Joëlle; Frerker, Christian; van Mieghem, Nicolas M; Linke, Axel; Worthley, Stephen; Asgar, Anita; Sgroi, Carmelo; Aziz, Mina; Danenberg, Haim D; Labinaz, Marino; Manoharan, Ganesh; Cheung, Anson; Webb, John G; Dvir, Danny

    2017-04-01

    Transcatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV). Patients included in the Valve-in-Valve International Data registry (VIVID) and treated with self-expanding THV devices were analyzed using centralized core laboratory blinded to clinical events. St. Jude Medical Portico versus Medtronic CoreValve were compared in a 1:2 fashion after propensity score matching. A total of 162 patients, Portico- (n=54) and CoreValve- (n=108) based valve-in-valve procedures comprised the study population with no significant difference in baseline characteristics (age, 79±8.2 years; 60% women; mean STS [Society of Thoracic Surgery] score 8.1±5.5%). Postimplantation, CoreValve was associated with a larger effective orifice area (1.67 versus 1.31 cm2; P=0.001), lower mean gradient (14±7.5 versus 17±7.5 mm Hg; P=0.02), and lower core laboratory-adjudicated moderate-to-severe aortic insufficiency (4.2% versus 13.7%; P=0.04), compared with Portico. Procedural complications including THV malpositioning, second THV requirement, or coronary obstruction were not significantly different between the 2 groups. Survival and stroke rates at 30 days were similar, but overall mortality at 1 year was higher among patients treated with Portico compared with CoreValve (22.6% versus 9.1%; P=0.03). In this first matched comparison of THVs for valve-in-valve implantations, Portico and CoreValve demonstrated differences in postprocedural hemodynamics and long-term clinical outcomes. Although this could be related to THV design characteristics, the impact of other procedural factors cannot be excluded and require further evaluation. © 2017 American Heart Association, Inc.

  6. Transcatheter aortic valve implantation with the self-expandable venus A-Valve and CoreValve devices: Preliminary Experiences in China.

    Science.gov (United States)

    Liao, Yan-Biao; Zhao, Zhen-Gang; Wei, Xin; Xu, Yuan-Ning; Zuo, Zhi-Liang; Li, Yi-Jian; Zheng, Ming-Xia; Feng, Yuan; Chen, Mao

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has been demonstrated to be an effective alternative to surgical aortic valve replacement (SAVR) in patients with aortic stenosis who are deemed high risk or inoperable. Currently, TAVI procedures in China mostly make use of the domestic Venus A-Valve and the CoreValve; however, there is no data on their comparative performance. Consecutive patients undergoing TAVI with the aforementioned devices were included. The outcomes were reported according to the Valve Academic Research Consortium-2 (VARC) definitions. A total of 54 TAVI procedures were performed, 27 with the CoreValve and the other 27 with the Venus A-Valve. An additional valve was required in 4 (14.8%) and 3 (11.1%) patients, and the VARC-2 device success rates were 81.5 and 85.2%, respectively. The incidences of common complications were similar, except for the significantly less frequent pacemaker insertion in the Venus A-Valve group (7.4 vs. 37.0%, P = 0.03). Within 30 days, 2 (3.7%) patients died, 1 in each group, and both had a bicuspid aortic valve (BAV). No other serious complications, such as annular rupture, coronary obstruction and aortic dissection, occurred in the 32 BAV patients treated with the Venus A-Valve (14) or the CoreValve (18). After 2-years of follow-up, there was no significant difference between CoreValve group and Venus-A group (11.1 vs. 7.4%, P = 0.64). TAVI with the domestic Venus A-Valve is feasible, safe, and can produce favorable short-term outcomes comparable to those with the CoreValve in inoperable or high-risk patients with tricuspid and bicuspid aortic valve stenosis. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. Shape Memory Actuated Normally Open Permanent Isolation Valve

    Science.gov (United States)

    Ramspacher, Daniel J. (Inventor); Bacha, Caitlin E. (Inventor)

    2017-01-01

    A valve assembly for an in-space propulsion system includes an inlet tube, an outlet tube, a valve body coupling the inlet tube to the outlet tube and defining a propellant flow path, a valve stem assembly disposed within the valve body, an actuator body coupled to the valve body, the valve stem assembly extending from an interior of the valve body to an interior of the actuator body, and an actuator assembly disposed within the actuator body and coupled to the valve stem assembly, the actuator assembly including a shape memory actuator member that when heated to a transition temperature is configured to enable the valve stem assembly to engage the outlet tube and seal the propellant flow path.

  8. EGNAS: an exhaustive DNA sequence design algorithm

    Directory of Open Access Journals (Sweden)

    Kick Alfred

    2012-06-01

    Full Text Available Abstract Background The molecular recognition based on the complementary base pairing of deoxyribonucleic acid (DNA is the fundamental principle in the fields of genetics, DNA nanotechnology and DNA computing. We present an exhaustive DNA sequence design algorithm that allows to generate sets containing a maximum number of sequences with defined properties. EGNAS (Exhaustive Generation of Nucleic Acid Sequences offers the possibility of controlling both interstrand and intrastrand properties. The guanine-cytosine content can be adjusted. Sequences can be forced to start and end with guanine or cytosine. This option reduces the risk of “fraying” of DNA strands. It is possible to limit cross hybridizations of a defined length, and to adjust the uniqueness of sequences. Self-complementarity and hairpin structures of certain length can be avoided. Sequences and subsequences can optionally be forbidden. Furthermore, sequences can be designed to have minimum interactions with predefined strands and neighboring sequences. Results The algorithm is realized in a C++ program. TAG sequences can be generated and combined with primers for single-base extension reactions, which were described for multiplexed genotyping of single nucleotide polymorphisms. Thereby, possible foldback through intrastrand interaction of TAG-primer pairs can be limited. The design of sequences for specific attachment of molecular constructs to DNA origami is presented. Conclusions We developed a new software tool called EGNAS for the design of unique nucleic acid sequences. The presented exhaustive algorithm allows to generate greater sets of sequences than with previous software and equal constraints. EGNAS is freely available for noncommercial use at http://www.chm.tu-dresden.de/pc6/EGNAS.

  9. Valve-in-valve outcome: design impact of a pre-existing bioprosthesis on the hydrodynamics of an Edwards Sapien XT valve.

    Science.gov (United States)

    Doose, Christian; Kütting, Maximilian; Egron, Sandrine; Farhadi Ghalati, Pejman; Schmitz, Christoph; Utzenrath, Marc; Sedaghat, Alexander; Fujita, Buntaro; Schmitz-Rode, Thomas; Ensminger, Stephan; Steinseifer, Ulrich

    2017-03-01

    Bioprosthetic aortic heart valves are increasingly implanted in younger patients. Therefore, a strategy for potential valve failure should be developed before implanting the 'first valve'. The goal of this in vitro study was to provide insight into the effects of the design of a bioprosthesis on a valve-in-valve implanted Sapien XT valve. The hydrodynamic performance of a 23-mm Sapien XT valve implanted in Vascutek Aspire, Edwards Perimount, Medtronic Mosaic and St. Jude Medical Trifecta heart valves was investigated in a left heart simulator. In addition to the hydrodynamic results, the leaflet dynamics were analysed in high-speed video recordings of the tests. All valve-in-valve combinations in this study fulfilled the minimum acceptance criteria defined by relevant approval standards (e.g. ISO 5840) but displayed significant differences in their performances. Small inner diameters of the bioprostheses were associated with increased mean pressure gradients, decreased effective orifice areas and geometric opening areas as well as with pin-wheeling and uneven leaflet motion. In addition, implantation in bioprostheses with internally mounted leaflets was associated with lower paravalvular leakage. The results of this study suggest that a surgical bioprosthesis with a large inner diameter and internally mounted leaflets improves the heamodynamics and potentially the durability of a valve-in-valve combination. These results should give the attending physicians critical information to consider when deciding on a bioprosthesis for younger patients.

  10. Infrared measurements of launch vehicle exhaust plumes

    Science.gov (United States)

    Schweitzer, Caroline; Ohmer, Phillip; Wendelstein, Norbert; Stein, Karin

    2017-10-01

    In the fields of early warning, one is depending on reliable analytical models for the prediction of the infrared threat signature: By having this as a basis, the warning sensors can be specified as suitable as possible to give timely threat approach alerts. In this paper, we will present preliminary results of measurement trials that have been carried out in 2015, where the exhaust plume of launch vehicles has been measured under various atmospheric conditions. The gathered data will be used to validate analytical models for the prediction of the plume signature.

  11. THE PROGNOSIS IN TRANSCATHETER AORTIC VALVE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    T. E. Imaev

    2016-01-01

    Full Text Available Aim. To study the effect of transcatheter aortic valve implantation (TAVI, performed by different types of prostheses and various surgical access, on the prognosis of patients with critical aortic stenosis and comorbidities.Material and methods. Patients (n=130 that had consistently performed 80 TAVI by Edwards valve transfemoral (n=50 and transapical (n=30 access, as well as 50 transcatheter aortic valve replacement by CoreValve system were included into the study. Complications including perioperative mortality, total 30-day mortality, as well as post-hospital mortality were registered during aortic valve replacement, immediately after surgery, before the expiry of 30 days. Mean follow-up was 2.2 years (range 0.2 to 5.2 years.Results. Hospital mortality was on average 6.9%. 121 patients had been discharged from the department after the surgery. The number of deaths in the post-hospital period was 14.8%. Valve type and the type of access had no effect on post-hospital mortality. Men died more than 2.5 times often than women, regardless of age. Atrioventricular block, pacemaker implantation, and history of chronic obstructive pulmonary disease were the most significant prognostic factors. An important role of minor stroke and renal failure should be noted. Mortality did not depend on the surgical access or valve type. All parameters characterizing the intervention were significantly associated with mortality, both during and after surgery. The proportion of survivors at the end of the first year of observation using Corvalve system was 86.9%, Edwards valve by transfemoral access - 88% and Edwards valve by transapical access – 85.4% (insignificant differences for all groups, p>0.05. Two-year survival was 77.5%, 82.5% and 82.7%, respectively (also insignificant differences for all groups, p>0.05.Conclusion. TAVI is the method of choice, reasonable alternative approach for surgical valve replacement in patients with high surgical risk, although

  12. Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Yoon, Sung Han; Lefèvre, Thierry; Ahn, Jung Ming

    2016-01-01

    Background Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices.  Objective...

  13. Anterior mitral valve aneurysm perforation secondary to aortic valve endocarditis detected by Doppler colour flow mapping.

    Science.gov (United States)

    Decroly, P; Vandenbossche, J L; Englert, M

    1989-02-01

    We report a case of mitral valve aneurysm formation and perforation, secondary to Streptococcus sanguis endocarditis of the aortic valve. Aneurysm formation was documented by cross-sectional echocardiography and its perforation was established by Doppler colour flow mapping, and subsequently confirmed at surgery.

  14. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure

  15. Bjork-Shiley convexoconcave valves: Susceptibility artifacts at brain MR imaging and mechanical valve fractures

    NARCIS (Netherlands)

    van Gorp, Maarten J.; van der Graaf, Yolanda; de Mol, Bas A. J. M.; Bakker, Chris J. G.; Witkamp, Theo D.; Ramos, Lino M. P.; Mali, Willem P. T. M.

    2004-01-01

    PURPOSE: To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Bjork-Shiley convexoconcave (BSCC) valves. MATERIALS AND METHODS: MR images of the brain were obtained in 58 patients with prosthetic heart

  16. [Heart valve prosthesis and pregnancy].

    Science.gov (United States)

    Ben-Ismail, M; Fekih, M; Taktak, M; Chelli, M

    1979-02-01

    Sixteen pregnancies were followed up in 13 patients with prosthetic heart valves: 8 pregnancies went to term under oral anticoagulation, 4 under heparin and 4 without anticoagulation. 9 healthy normal children were delivered; there were 2 still births and 5 abortions. On the maternal side 3 haemorrhages and thromboembolic episodes which involved 2 patients on heparin, one of whom died, were observed. The following points are apparent from our observations and a review of the existing medical literature: --the risk of thromboembolism is not increased. The marked clotting tendency of maternal blood post-partum contraindicates the withdrawal of anticoagulants during this critical period; --haemorrhagic complications are common with anticoagulants; --foetal loss is greatly increased; --the teratogenecity of vitamin-K antagonists is certain, but the risk is small. The problems of anticoagulation are discussed; theoretically heparin should be given during the 1st trimestre and from the 38th week to the second post-partum week. The patients should be closely supervised by both obstetrician and cardiologist and hospitalisation is advised for the last month of pregnancy. Normal vaginal delivery is usually possible.

  17. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  18. Simplified surgical-hybrid Melody valve implantation for paediatric mitral valve disease.

    Science.gov (United States)

    Hofmann, Michael; Dave, Hitendu; Hübler, Michael; Kretschmar, Oliver

    2015-05-01

    Children suffering from left atrioventricular valve (LAVV) disease not amenable to repair represent a significant challenge. The results of surgical reconstruction are not optimal. Valve replacement as an alternative is associated with poor results. The surgical-hybrid approach with implantation of a stented biological valve (bovine jugular vein graft, Melody valve) seems to represent a new therapeutic option. Here we demonstrate our case, the consideration and the approach to extreme clinical findings in a small child. We describe a simplified surgical-hybrid Melody valve implantation in a LAVV position. The technique of implantation is relatively simple and the immediate postoperative result very good. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Thrombolytic therapy in prosthetic valve thrombosis during early pregnancy

    Directory of Open Access Journals (Sweden)

    B.C. Srinivas

    2012-01-01

    Full Text Available Regardless of the improvements in the design of prosthetic heart valves and the use of anticoagulation, systemic embolism and valve thrombosis remains the most dreaded complications of mechanical heart valve replacement. A course of thrombolytic therapy may be considered as a first-line therapy for prosthetic heart valve thrombosis. The safety of thrombolysis in early pregnancy is not known. We describe a primigravida with mitral valve replacement status presenting with acute prosthetic valve thrombosis and treated successfully with intravenous streptokinase.

  20. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    Science.gov (United States)

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  1. Effect of transcatheter aortic valve size and position on valve-in-valve hemodynamics: An in vitro study.

    Science.gov (United States)

    Azadani, Ali N; Reardon, Michael; Simonato, Matheus; Aldea, Gabriel; Nickenig, Georg; Kornowski, Ran; Dvir, Danny

    2017-06-01

    Transcatheter heart valve implantation in failed aortic bioprostheses (valve-in-valve [ViV]) is an increasingly used therapeutic option for high-risk patients. However, high postprocedural gradients are a significant limitation of aortic ViV. Our objective was to evaluate Medtronic CoreValve Evolut R ViV hemodynamics in relation to the degree of device oversizing and depth of implantation. Evolut R devices of 23 and 26 mm were implanted within 21-, 23-, and 25-mm Hancock II bioprostheses. Small and gradual changes in implantation depth were attempted. Hemodynamic testing was performed in a pulse duplicator under ISO-5840 standard. A total of 47 bench-testing experiments were performed. The mean gradient of the 26-mm Evolut R in 23- and 25-mm Hancock II was lower than 23-mm Evolut R (P  17.5 mm. The current comprehensive bench-testing assessment demonstrates the importance of both transcatheter heart valve size and device position for the attainment of optimal hemodynamics during ViV procedures. Additional in vitro testing may be required to develop hemodynamics-based guidelines for device sizing in ViV procedures in degenerated surgical bioprostheses. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  2. Effect of EGR on the exhaust gas temperature and exhaust opacity ...

    Indian Academy of Sciences (India)

    In diesel engines, NOx formation is a highly temperature-dependent phenomenon and takes place when the temperature in the combustion chamber exceeds 2000 K. Therefore, in order to reduce NOx emissions in the exhaust, it is necessary to keep peak combustion temperatures under control. One simple way of ...

  3. Pilot licensing after aortic valve surgery.

    Science.gov (United States)

    Syburra, Thomas; Schnüriger, Hans; Kwiatkowski, Barbara; Graves, Kirk; Reuthebuch, Oliver; Genoni, Michele

    2010-05-01

    Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time. It is rare that pilots undergo aortic valve surgery, and the confirmation of flight-licensing requirements after aortic valve replacement (AVR) is a challenge for the patient's cardiac surgeon and, particularly, for the Aeromedical Examiner (AME). Only AMEs are able to determine the flight status of pilots. Furthermore, in military and in civil aviation (e.g., Red Bull Air Race), the high G-load environment experienced by pilots is an exceptional physiological parameter, which must be considered postoperatively. A review was conducted of the aeronautical, surgical and medical literature, and of European pilot-licensing regulations. Case studies are also reported for two Swiss Air Force pilots. According to European legislation, pilots can return to flight duty from the sixth postoperative month, with the following limitations: that an aortic bioprosthesis presents no restrictions in cardiac function, requires no cardioactive medications, yet requires a flight operation with co-pilot, the avoidance of accelerations over +3 Gz and, in military aviation, restricts the pilot to non-ejection-seat aircraft. The patient follow up must include both echocardiographic and rhythm assessments every six months. Mechanical prostheses cannot be certified because the required anticoagulation therapy is a disqualifying condition for pilot licensing. Pilot licensing after aortic valve surgery is possible, but with restrictions. The +Gz exposition is of concern in both military and civilian aviation (aerobatics). The choice of bioprosthesis type and size is determinant. Pericardial and stentless valves seem to show better flow characteristics under high-output conditions. Repetitive cardiological controls are mandatory for the early assessment of structural valve disease and rhythm disturbances. A pre-emptive timing is

  4. Lined 10'' butterfly valve outlasts competitive valves in brine filter system

    Energy Technology Data Exchange (ETDEWEB)

    Gaines, A.

    1982-03-01

    One of the world's largest chlorine production units located in the Gulf Coast area has an extensive brine piping system with a large number of valves. Some of the valves performed well but many failed to meet the service requirements, especially in the brine filtering system with the salt solution at ambient temperatures and pressures about 100 psi. One of these was a 10'' valve. Various types of gear-operated butterfly valves, with an elastomer lining to withstand the somewhat corrosive solution, had been tried but developed leaks and had to be repaired or replaced after 4 to 6 months. The valves became difficult or impossible to operate in some cases when brine leaking past the stem seal attacked the inner surface of the metal valve body and the liner was dislodged by the movement of the disc. In September 1980, a 10'' butterfly valve specifically designed for bubble-tight shut off and zero stem leakage was installed in the brine filter line on a trial basis. The valve has a 1-piece, epoxy-coated ductile iron body with a molded one-piece liner of Hypalon rubber, and a stainless steel stem and disc with splines instead of pins to provide a trouble-free connection. The stem is positively sealed against leakage by a patented spherical machining process on both the disc and the liner. The valve was furnished with a variable ratio gear actuator that has higher torque output when the disc begins to make contact with the seat to assure a bubble-tight shutoff with minimum input torque. The butterfly valve has provided leaktight performance since it was installed in September 1980 and is still easy to open and close by the geared actuator.

  5. Loss of Axin2 results in impaired heart valve maturation and subsequent myxomatous valve disease.

    Science.gov (United States)

    Hulin, Alexia; Moore, Vicky; James, Jeanne M; Yutzey, Katherine E

    2017-01-01

    Myxomatous valve disease (MVD) is the most common aetiology of primary mitral regurgitation. Recent studies suggest that defects in heart valve development can lead to heart valve disease in adults. Wnt/β-catenin signalling is active during heart valve development and has been reported in human MVD. The consequences of increased Wnt/β-catenin signalling due to Axin2 deficiency in postnatal valve remodelling and pathogenesis of MVD were determined. To investigate the role of Wnt/β-catenin signalling, we analysed heart valves from mice deficient in Axin2 (KO), a negative regulator of Wnt/β-catenin signalling. Axin2 KO mice display enlarged mitral and aortic valves (AoV) after birth with increased Wnt/β-catenin signalling and cell proliferation, whereas Sox9 expression and collagen deposition are decreased. At 2 months in Axin2 KO mice, the valve extracellular matrix (ECM) is stratified but distal AoV leaflets remain thickened and develop aortic insufficiency. Progressive myxomatous degeneration is apparent at 4 months with extensive ECM remodelling and focal aggrecan-rich areas, along with increased BMP signalling. Infiltration of inflammatory cells is also observed in Axin2 KO AoV prior to ECM remodelling. Overall, these features are consistent with the progression of human MVD. Finally, Axin2 expression is decreased and Wnt/β-catenin signalling is increased in myxomatous mitral valves in a murine model of Marfan syndrome, supporting the importance of Wnt/β-catenin signalling in the development of MVD. Altogether, these data indicate that Axin2 limits Wnt/β-catenin signalling after birth and allows proper heart valve maturation. Moreover, dysregulation of Wnt/β-catenin signalling resulting from loss of Axin2 leads to progressive MVD. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  6. Aircraft exhaust aerosol formation and growth

    Energy Technology Data Exchange (ETDEWEB)

    Brown, R.C.; Miake-Lye, R.C.; Anderson, M.R.; Kolb, C.E. [Aerodyne Research, Inc., Billerica, MA (United States). Center for Chemical and Environmental Physics

    1997-12-31

    Aerosol formation and growth in the exhaust plume of the ATTAS aircraft at an altitude of approximately 9 km, burning fuels with 2 ppmm sulfur (`low`) and 266 ppmm (`high`) sulfur has been modeled using an aerosol dynamics model for nucleation, vapor condensation and coagulation, coupled to a 2-dimensional, axisymmetric flow code to treat plume dilution and turbulent mixing. For both the `low` and `high` sulfur fuels, approximately 60% of the available water had condensed within the first 200 m downstream of the exhaust exit. The contrail particle diameters ranged between 0.4 to 1.6 {mu}m. However, the size distributions as a function of radial position for the `low` sulfur plume were broader than the corresponding distributions for the `high` sulfur plume. The model results indicate for a fuel sulfur mass loading of 2 ppmm, sulfuric acid remains a viable activating agent and that the differences in the contrail particle size distributions for sulfur mass loadings between 2 ppmm and 260 ppmm would be difficult to detect. (author) 12 refs.

  7. On the exhaust of electromagnetic drive

    Directory of Open Access Journals (Sweden)

    Patrick Grahn

    2016-06-01

    Full Text Available Recent reports about propulsion without reaction mass have been met on one hand with enthusiasm and on the other hand with some doubts. Namely, closed metal cavities, when fueled with microwaves, have delivered thrust that could eventually maintain satellites on orbits using solar power. However, the measured thrust appears to be without any apparent exhaust. Thus the Law of Action-Reaction seems to have been violated. We consider the possibility that the exhaust is in a form that has so far escaped both experimental detection and theoretical attention. In the thruster’s cavity microwaves interfere with each other and invariably some photons will also end up co-propagating with opposite phases. At the destructive interference electromagnetic fields cancel. However, the photons themselves do not vanish for nothing but continue in propagation. These photon pairs without net electromagnetic field do not reflect back from the metal walls but escape from the resonator. By this action momentum is lost from the cavity which, according to the conservation of momentum, gives rise to an equal and opposite reaction. We examine theoretical corollaries and practical concerns that follow from the paired-photon conclusion.

  8. Local Pain Dynamics during Constant Exhaustive Exercise.

    Directory of Open Access Journals (Sweden)

    Agne Slapsinskaite

    Full Text Available The purpose of this study was to delineate the topological dynamics of pain and discomfort during constant exercise performed until volitional exhaustion. Eleven physical education students were tested while cycling and running at a "hard" intensity level (e.g., corresponding to Borg's RPE (6-20 = 15. During the tests, participants reported their discomfort and pain on a body map every 15s. "Time on task" for each participant was divided into five equal non-overlapping temporal windows within which their ratings were considered for analysis. The analyses revealed that the number of body locations with perceived pain and discomfort increased throughout the five temporal windows until reaching the mean (± SE values of 4.2 ± 0.7 and 4.1 ± 0.6 in cycling and running, respectively. The dominant locations included the quadriceps and hamstrings during cycling and quadriceps and chest during running. In conclusion, pain seemed to spread throughout the body during constant cycling and running performed up to volitional exhaustion with differences between cycling and running in the upper body but not in the lower body dynamics.

  9. Measurement of alkali in PFBC exhaust

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.H.D.; Swift, W.M.

    1992-11-01

    This project supports the DOE/METC Fossil Energy Program for the development of PFBC technology. Based on the analytical activated-bauxite sorber-bed technique, we are developing the RABSAM as an altemative to the on-line alkali analyzer for field application. As shown in Fig. 1, the RABSAM is a sampling probe containing a regenerable activated-bauxite adsorbent (RABA). It can be inserted directly into the PFBC exhaust duct and requires no HTHP sampling line. Alkali vapors are captured by the adsorbent purely through physical adsorption. The adsorbent is regenerated by a simple water-leaching process, which also recovers the adsorbed alkalis. The alkali analysis of the leachate by atomic absorption (AA) provides a basis for calculating the time-averaged alkali-vapor concentration in the PFBC exhaust. If the RABA is to use commercial grade activated bauxite, the clay impurities in activated bauxite can react with alkali vapors and, therefore, need to be either removed or deactivated. In earlier work, a 6M-LiCl-solution impregnation technique was shown to deactivate these impurities in fresh activated bauxite [8]. During this year, RABA prepared by this technique was tested in a pressurized alkali-vapor sorption test unit to determine its NaCl-vapor capture efficiency and the regenerability of the sorbent by water extraction. Results of this study are presented and discussed.

  10. Measurement of alkali in PFBC exhaust

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.H.D.; Swift, W.M.

    1992-01-01

    This project supports the DOE/METC Fossil Energy Program for the development of PFBC technology. Based on the analytical activated-bauxite sorber-bed technique, we are developing the RABSAM as an altemative to the on-line alkali analyzer for field application. As shown in Fig. 1, the RABSAM is a sampling probe containing a regenerable activated-bauxite adsorbent (RABA). It can be inserted directly into the PFBC exhaust duct and requires no HTHP sampling line. Alkali vapors are captured by the adsorbent purely through physical adsorption. The adsorbent is regenerated by a simple water-leaching process, which also recovers the adsorbed alkalis. The alkali analysis of the leachate by atomic absorption (AA) provides a basis for calculating the time-averaged alkali-vapor concentration in the PFBC exhaust. If the RABA is to use commercial grade activated bauxite, the clay impurities in activated bauxite can react with alkali vapors and, therefore, need to be either removed or deactivated. In earlier work, a 6M-LiCl-solution impregnation technique was shown to deactivate these impurities in fresh activated bauxite [8]. During this year, RABA prepared by this technique was tested in a pressurized alkali-vapor sorption test unit to determine its NaCl-vapor capture efficiency and the regenerability of the sorbent by water extraction. Results of this study are presented and discussed.

  11. Exhaust constituent emission factors of printed circuit board pyrolysis processes and its exhaust control

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Hung-Lung, E-mail: hlchiang@mail.cmu.edu.tw [Department of Health Risk Management, China Medical University, Taichung, Taiwan (China); Lin, Kuo-Hsiung [Department of Environmental Engineering and Science, Fooyin University, Kaohsiung, Taiwan (China)

    2014-01-15

    Highlights: • Recycling of waste printed circuit boards is an important issue. • Pyrolysis is an emerging technology for PCB treatment. • Emission factors of VOCs are determined for PCB pyrolysis exhaust. • Iron-Al{sub 2}O{sub 3} catalyst was employed for the exhaust control. -- Abstract: The printed circuit board (PCB) is an important part of electrical and electronic equipment, and its disposal and the recovery of useful materials from waste PCBs (WPCBs) are key issues for waste electrical and electronic equipment. Waste PCB compositions and their pyrolysis characteristics were analyzed in this study. In addition, the volatile organic compound (VOC) exhaust was controlled by an iron-impregnated alumina oxide catalyst. Results indicated that carbon and oxygen were the dominant components (hundreds mg/g) of the raw materials, and other elements such as nitrogen, bromine, and copper were several decades mg/g. Exhaust constituents of CO, H{sub 2}, CH{sub 4}, CO{sub 2}, and NOx, were 60–115, 0.4–4.0, 1.1–10, 30–95, and 0–0.7 mg/g, corresponding to temperatures ranging from 200 to 500 °C. When the pyrolysis temperature was lower than 300 °C, aromatics and paraffins were the major species, contributing 90% of ozone precursor VOCs, and an increase in the pyrolysis temperature corresponded to a decrease in the fraction of aromatic emission factors. Methanol, ethylacetate, acetone, dichloromethane, tetrachloromethane and acrylonitrile were the main species of oxygenated and chlorinated VOCs. The emission factors of some brominated compounds, i.e., bromoform, bromophenol, and dibromophenol, were higher at temperatures over 400 °C. When VOC exhaust was flowed through the bed of Fe-impregnated Al{sub 2}O{sub 3}, the emission of ozone precursor VOCs could be reduced by 70–80%.

  12. LMFBR large valve development. Comparison study of advantages and disadvantages of foreign design of offset pivot butterfly valves with AMCO's offset pivot ball valve

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, L.

    1975-02-01

    The purpose of this effort was to compare the advantages and disadvantages of foreign designs of offset pivot butterfly valves presented during a specialists meeting on Operating Experience and Design Criteria of Sodium Valves with the characteristics of the present AMCO offset pivot ball valve design concept. In addition, the comparison was directed to indicating if work on a butterfly concept should be initiated by AMCO. This work could be in parallel with or in lieu of, the present AMCO effort on an offset pivot ball valve for isolation valve purposes.

  13. Durability of pericardial versus porcine bioprosthetic heart valves.

    Science.gov (United States)

    Grunkemeier, Gary L; Furnary, Anthony P; Wu, YingXing; Wang, Lian; Starr, Albert

    2012-12-01

    To compare the probability, and modes, of explantation for Carpentier-Edwards pericardial versus porcine valves. Our porcine series began in 1974 and our pericardial series in 1991, with annual prospective follow-up. We used the Kaplan-Meier method and Cox regression for estimation and analysis of patient mortality, and the cumulative incidence function and competing risks regression for estimation and analysis of valve durability. Through the end of 2010, we had implanted 506 porcine and 2449 pericardial aortic valves and 181 porcine and 163 pericardial mitral valves. The corresponding total and maximum follow-up years were 3471 and 24, 11,517 and 18, 864 and 22, and 645 and 9. The corresponding probabilities (cumulative incidence function) of any valve explant were 7%, 8%, 22%, and 8%, and of explant for structural valve deterioration were 4%, 5%, 16%, and 5% at 15 years for the first 3 series and at 8 years for the fourth (pericardial mitral valve) series. Using competing risks regression for structural valve deterioration explant, with age, gender, valve size, and concomitant coronary bypass surgery as covariates, a slight (subhazard ratio, 0.79), but nonsignificant, protective effect was found for the pericardial valve in the aortic position and a greater (subhazard ratio, 0.31) and almost significant (P = .08) protective effect of the pericardial valve in the mitral position. Leaflet tear was responsible for 61% of the structural valve deterioration explants in the porcine series and 46% in the pericardial series. Using competing risks regression, the pericardial valve had a subhazard ratio for structural valve deterioration explant of less than 1 in both positions, approaching statistical significance in the mitral position. The mode of structural valve deterioration was predominantly leaflet tear for porcine valves and fibrosis/calcification for pericardial valves. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc

  14. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  15. Cardiac crossroads: deciding between mechanical or bioprosthetic heart valve replacement

    Directory of Open Access Journals (Sweden)

    Maggie N Tillquist

    2011-02-01

    Full Text Available Maggie N Tillquist1, Thomas M Maddox21School of Medicine, University of Colorado Denver, Denver, CO, USA; 2VA Eastern Colorado Health Care System, and Department of Medicine (Cardiology, University of Colorado Denver, Denver, CO, USAAbstract: Nearly 15 million people in the United States suffer from either aortic or mitral valvular disease. For patients with severe and symptomatic valvular heart disease, valve replacement surgery improves morbidity and mortality outcomes. In 2009, 90,000 valve replacement surgeries were performed in the United States. This review evaluates the advantages and disadvantages of mechanical and bioprosthetic prosthetic heart valves as well as the factors for consideration in deciding the appropriate valve type for an individual patient. Although many caveats exist, the general recommendation is for patients younger than 60 to 65 years to receive mechanical valves due to the valve's longer durability and for patients older than 60 to 65 years to receive a bioprosthetic valve to avoid complications with anticoagulants. Situations that warrant special consideration include patient co-morbidities, the need for anticoagulation, and the potential for pregnancy. Once these characteristics have been considered, patients' values, anxieties, and expectations for their lifestyle and quality of life should be incorporated into final valve selection. Decision aids can be useful in integrating preferences in the valve decision. Finally, future directions in valve technology, anticoagulation, and medical decision-making are discussed.Keywords: prosthetic heart valves, patient preference, valve type, anticoagulant, structural valve deterioration 

  16. Valvular Heart Disease in Adults: Management of Prosthetic Heart Valves.

    Science.gov (United States)

    Trujillo, John F; Hollenberg, Steven M

    2017-06-01

    Patients undergoing cardiac valve replacement may receive mechanical or bioprosthetic valves. Mechanical valves require lifelong anticoagulation but are durable and the need for a second surgery is up to eightfold times less than with bioprosthetic valves. Bioprosthetic valves do not require lifelong anticoagulation and thus are associated with fewer bleeding complications but they are less durable and associated with higher morbidity and mortality rates, particularly in younger patients. Anticoagulation with mechanical valves is achieved using warfarin; use of direct-acting oral anticoagulants is not indicated. Concomitant low-dose aspirin is recommended for patients with mechanical valves and as sole thromboembolism prophylaxis for patients receiving aortic or mitral bioprosthetic valves. If a patient taking warfarin is to undergo a surgical procedure that requires interruption of anticoagulation, bridging therapy with heparin is indicated if the patient has a mechanical aortic valve and any risk of thromboembolism, an older-generation mechanical aortic valve, or a mechanical mitral valve. Warfarin is teratogenic; pregnant women should take heparin. Patients with mechanical or bioprosthetic valves should receive antibiotic prophylaxis before some dental and surgical procedures to prevent endocarditis. Thrombolytic therapy should be considered in patients who develop a thrombus on a valve that does not resolve with heparin. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  17. Osseous and chondromatous metaplasia in calcific aortic valve stenosis.

    Science.gov (United States)

    Torre, Matthew; Hwang, David H; Padera, Robert F; Mitchell, Richard N; VanderLaan, Paul A

    2016-01-01

    Aortic valve replacement for calcific aortic valve stenosis is one of the more common cardiac surgical procedures. However, the underlying pathophysiology of calcific aortic valve stenosis is poorly understood. We therefore investigated the histologic findings of aortic valves excised for calcific aortic valve stenosis and correlated these findings with their associated clinical features. We performed a retrospective analysis on 6685 native aortic valves excised for calcific stenosis and 312 prosthetic tissue aortic valves with calcific degeneration at a single institution between 1987 and 2013. Patient demographics were correlated with valvular histologic features diagnosed on formalin-fixed, decalcified, and paraffin embedded hematoxylin and eosin stained sections. Of the analyzed aortic valves, 5200 (77.8%) were tricuspid, 1473 (22%) were bicuspid, 11 (0.2%) were unicuspid, and 1 was quadricuspid. The overall prevalence of osseous and/or chondromatous metaplasia was 15.6%. Compared to tricuspid valves, bicuspid valves had a higher prevalence of metaplasia (30.1% vs. 11.5%) and had an earlier mean age of excision (60.2 vs. 75.1 years old). In addition, the frequency of osseous metaplasia and/or chondromatous metaplasia increased with age at time of excision of bicuspid aortic valves, while tricuspid aortic valves showed the same incidence regardless of patient age. Males had a higher prevalence of metaplasia in both bicuspid (33.5% vs. 22.3%) and tricuspid (13.8% vs. 8.6%) aortic valves compared to females. Osseous metaplasia and/or chondromatous metaplasia was also more common in patients with bicuspid aortic valves and concurrent chronic kidney disease or atherosclerosis than in those without (33.6% vs. 28.3%). No osseous or chondromatous metaplasia was observed within the cusps of any of the prosthetic tissue valves. Osseous and chondromatous metaplasia are common findings in native aortic valves but do not occur in prosthetic tissue aortic valves. Bicuspid

  18. Electrical Textile Valves for Paper Microfluidics.

    Science.gov (United States)

    Ainla, Alar; Hamedi, Mahiar M; Güder, Firat; Whitesides, George M

    2017-10-01

    This paper describes electrically-activated fluidic valves that operate based on electrowetting through textiles. The valves are fabricated from electrically conductive, insulated, hydrophobic textiles, but the concept can be extended to other porous materials. When the valve is closed, the liquid cannot pass through the hydrophobic textile. Upon application of a potential (in the range of 100-1000 V) between the textile and the liquid, the valve opens and the liquid penetrates the textile. These valves actuate in less than 1 s, require low energy (≈27 µJ per actuation), and work with a variety of aqueous solutions, including those with low surface tension and those containing bioanalytes. They are bistable in function, and are, in a sense, the electrofluidic analog of thyristors. They can be integrated into paper microfluidic devices to make circuits that are capable of controlling liquid, including autonomous fluidic timers and fluidic logic. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Radiological findings of congenital urethral valves

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Kyung Mo; Kook, Shin Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Congenital urethral valve is the common cause of hydronephrosis in newborn infants and the most common cause of bladder outlet obstruction in male children. We reviewed and analysed radiological findings and associated anomalies of 16 cases of congenital urethral valve which were examined during the period from January 1985 to December 1989. The most frequent age was under one year old (56%). The main symptoms were urinary dribbing (37.5%), weak stream (25%) and urinary frequency and incontinence (25%). Anterior urethral valve (AUV) was 5 cases (31%) and posterior urethral valve (PUV) was 11 cases(69%), in which 10 cases were Type I and one case was Type III. Bladder wall thickening was seen in all cases and its severity was partly correlated with the degree of vesicoureteral reflux (VUR). VUR was observed in 12 cases (75%), and relatively severe in older age group. The degree of VUR was milder in AUV than PUV. Hydronephrosis was more severe in PUV than in anterior one, and its degree was correlated with the severity of VUR. Associated anomalies were ectopic urethral opening (2 cases), PDA (1 case), congenital megacolon (1 case) and patent urachus (1 case) in PUV. So early diagnosis and treatment of congenital urethral valve is essential to the prevention of renal damage.

  20. Vehicle exhaust: An overstated cause of haze in China.

    Science.gov (United States)

    Zhao, Yi-Bo; Gao, Pan-Pan; Yang, Wan-Dong; Ni, Hong-Gang

    2018-01-15

    Overall, total exhaust emissions of NOX, VOC and particulate matter (PM) declined, though vehicles in use continued to increase in China. This suggested that contribution of motor vehicle exhaust to haze in China may be exaggerated. A higher frequency of haze episodes in China with lower total emissions fraction from vehicle exhaust compared with those in the USA confirmed that there exists no strict causality between vehicle and haze. No significant correlation (pvehicles to airborne PM2.5 (particulates that are aerodynamic diameter) or car ownerships. All results revealed again that vehicle exhaust is an overstated cause for haze formation in China. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Molecular and cellular insights into T cell exhaustion

    Science.gov (United States)

    Wherry, E. John; Kurachi, Makoto

    2016-01-01

    In chronic infections and cancer, T cells are exposed to persistent antigen and/or inflammatory signals. This scenario is often associated with the deterioration of T cell function: a state called ‘exhaustion’. Exhausted T cells lose robust effector functions, express multiple inhibitory receptors and are defined by an altered transcriptional programme. T cell exhaustion is often associated with inefficient control of persisting infections and tumours, but revitalization of exhausted T cells can reinvigorate immunity. Here, we review recent advances that provide a clearer molecular understanding of T cell exhaustion and reveal new therapeutic targets for persisting infections and cancer. PMID:26205583

  2. T-cell exhaustion in allograft rejection and tolerance.

    Science.gov (United States)

    Thorp, Edward B; Stehlik, Christian; Ansari, M Javeed

    2015-02-01

    The role of T-cell exhaustion in the failure of clearance of viral infections and tumors is well established. There are several ongoing trials to reverse T-cell exhaustion for treatment of chronic viral infections and tumors. The mechanisms leading to T-cell exhaustion and its role in transplantation, however, are only beginning to be appreciated and are the focus of the present review. Exhausted T cells exhibit a distinct molecular profile reflecting combinatorial mechanisms involving the interaction of multiple transcription factors important in control of cell metabolism, acquisition of effector function and memory capacity. Change of microenvironmental cues and limiting leukocyte recruitment can modulate T-cell exhaustion. Impaired leukocyte recruitment induces T-cell exhaustion and prevents allograft rejection. Preventing or reversing T-cell exhaustion may lead to prevention of transplant tolerance or triggering of rejection; therefore, caution should be exercised in the use of agents blocking inhibitory receptors for the treatment of chronic viral infections or tumors in transplant recipients. Further definition of the role of T-cell exhaustion in clinical transplantation and an understanding of the mechanisms of induction of T-cell exhaustion are needed to develop strategies for preventing allograft rejection and induction of tolerance.

  3. T-cell exhaustion in the tumor microenvironment

    National Research Council Canada - National Science Library

    Jiang, Y; Li, Y; Zhu, B

    2015-01-01

    .... The exhausted T cells in the tumor microenvironment show overexpressed inhibitory receptors, decreased effector cytokine production and cytolytic activity, leading to the failure of cancer elimination...

  4. The exhaust heat management system; Das Abgaswaerme-Management

    Energy Technology Data Exchange (ETDEWEB)

    Geskes, P.; Strauss, T. [Behr GmbH und Co., Stuttgart (Germany)

    2006-10-15

    Behr uses EGR coolers in its Exhaust Heat Management System (EHMS) to obtain exhaust enthalpy, helping to heat up the vehicle cabin faster, or to reduce the power train warm-up phase. In today's DI diesel and DI gasoline engines, auxiliary heating is essential to ensure thermal comfort, since fuel-efficient vehicles no longer transmit sufficient heat to the coolant. By modifying the internal engine combustion, which produces much higher exhaust temperatures, auxiliary heating by th exhaust heat can provide extremely high thermal output in conjunction with just a slight increase in fuel consumption. (orig.)

  5. TCT-670 Optimal Transcatheter Heart Valve Sizing in Aortic Valve in Valve Implantation: Insights from the Valve in Valve International Data (VIVID) Registry

    DEFF Research Database (Denmark)

    Alnasser, Sami; Cheema, Asim N; Horlick, Eric

    2016-01-01

    )/true ID x 100. Results: A total of 595 patients (359 for standard size and 236 for oversized group) were included in the analysis. Baseline clinical, hemodynamic and surgical valve parameters were similar in these two groups. Both groups used similar THV devices in each matched comparison. The oversized.......1±8.1mmHg vs. 17.4±8.5mmHg, p=0.002) in comparison to the standard cohort. The oversized group however, had a higher rate of moderate to severe AI (6.9% vs. 2.7%, p=0.001) and second THV requirement (5.5%vs. 2.2%, p=0.04). THV mal-positioning, coronary obstruction and postoperative pacemaker requirement...

  6. GASOLINE VEHICLE EXHAUST PARTICLE SAMPLING STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Kittelson, D; Watts, W; Johnson, J; Zarling, D Schauer,J Kasper, K; Baltensperger, U; Burtscher, H

    2003-08-24

    The University of Minnesota collaborated with the Paul Scherrer Institute, the University of Wisconsin (UWI) and Ricardo, Inc to physically and chemically characterize the exhaust plume from recruited gasoline spark ignition (SI) vehicles. The project objectives were: (1) Measure representative particle size distributions from a set of on-road SI vehicles and compare these data to similar data collected on a small subset of light-duty gasoline vehicles tested on a chassis dynamometer with a dilution tunnel using the Unified Drive Cycle, at both room temperature (cold start) and 0 C (cold-cold start). (2) Compare data collected from SI vehicles to similar data collected from Diesel engines during the Coordinating Research Council E-43 project. (3) Characterize on-road aerosol during mixed midweek traffic and Sunday midday periods and determine fleet-specific emission rates. (4) Characterize bulk- and size-segregated chemical composition of the particulate matter (PM) emitted in the exhaust from the gasoline vehicles. Particle number concentrations and size distributions are strongly influenced by dilution and sampling conditions. Laboratory methods were evaluated to dilute SI exhaust in a way that would produce size distributions that were similar to those measured during laboratory experiments. Size fractionated samples were collected for chemical analysis using a nano-microorifice uniform deposit impactor (nano-MOUDI). In addition, bulk samples were collected and analyzed. A mixture of low, mid and high mileage vehicles were recruited for testing during the study. Under steady highway cruise conditions a significant particle signature above background was not measured, but during hard accelerations number size distributions for the test fleet were similar to modern heavy-duty Diesel vehicles. Number emissions were much higher at high speed and during cold-cold starts. Fuel specific number emissions range from 1012 to 3 x 1016 particles/kg fuel. A simple

  7. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Science.gov (United States)

    Zhang, Ben; Chen, Xiang; Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. This design of the

  8. Transseptal transcatheter mitral valve-in-valve: A step by step guide from preprocedural planning to postprocedural care.

    Science.gov (United States)

    Guerrero, Mayra; Salinger, Michael; Pursnani, Amit; Pearson, Paul; Lampert, Mark; Levisay, Justin; Russell, Hyde; Feldman, Ted

    2017-05-30

    Transcatheter mitral valve replacement has been successfully performed with the use of aortic transcatheter heart valves in hundreds of patients worldwide with severe dysfunction of a degenerated mitral bioprosthesis and high surgical risk for repeat operation. The delivery approach in the vast majority of the mitral valve-in-valve procedures has been transapical. Although the transseptal approach may be more technically challenging, it is less invasive and may be preferred by patients. Data from case series and a large international registry suggest that patients treated with transseptal mitral valve-in-valve have faster recovery, more improvement in left ventricular ejection fraction and possibly lower mortality compared with patients treated with transapical approach. A prospective clinical trial, the MITRAL trial (Mitral Implantation of TRAnscatheter vaLves) is evaluating the safety and feasibility of transvenous transseptal mitral valve-in-valve. The experience from this trial has allowed us to improve our procedural approach. In anticipation of a wider adoption of the transseptal approach for mitral valve-in-valve, we describe our current method step-by-step from planning the procedure through postprocedural management. This is an evolving technique that has changed with experience and the transition to newer generation transcatheter heart valve devices. We discuss the use of cardiac computed tomography for planning the procedure including transseptal puncture and valve size selection, provide procedural and technical tips, and discuss postprocedural care. © 2017 Wiley Periodicals, Inc.

  9. Mechanical Designs for Relief Valves for Cryogenic Apparatuses and Installations

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    There are also pressure relief valves with warm seat available on which the set pressure is based on an adjustment of forces by permanent magnets. Pressure vessel rules allows also the choice for an active triggered pressure relief valve (Cont...

  10. Recognizing the Symptoms of Worsening Heart Valve Disease

    Science.gov (United States)

    ... be hard to separate our habits from the mechanics of our hearts, which is one important reason ... About Heart Valves • Heart Valve Problems and Causes • Risks, Signs and Symptoms Introduction Understanding Symptoms Recognizing Symptoms ...

  11. TRINITY heart valve prosthesis: a novel repositionable and retrievable transapical transcatheter aortic valve system.

    Science.gov (United States)

    Hengstenberg, Christian; Condado, Jose; Garcia, David; Martinez, Milka Marin; La Forgia, Giambattista; Ebner, Adrian; Gallo, Santiago; Silva, Enrique; Holzamer, Andreas; Husser, Oliver; Hilker, Michael

    2015-03-01

    Transcatheter aortic valve implantation (TAVI) has become a viable option for selected high-risk patients with severe and symptomatic aortic stenosis. First- and second-generation TAVI devices are either self- or balloon-expandable, and are often not repositionable or not fully retrievable, leading to suboptimal positioning in some cases. This may result in paravalvular regurgitation, AV conduction delay, or compromise of coronary perfusion. A broader application of TAVI requires advances in both valve and delivery systems. Therefore, in order to facilitate accurate positioning, to minimise paravalvular leakage, possibly to reduce the risk of AV conduction delay, and possibly to be able to abort the procedure, a "next-generation" TAVI system has been developed which is repositionable and retrievable, the TRINITY heart valve system. The TRINITY heart valve system was implanted in a first-in-human study using the transapical approach to demonstrate feasibility and procedural success. All endpoints were adjudicated according to VARC definitions at seven and 30 days. The TRINITY heart valve system was implanted in a 74-year-old patient with severe symptomatic aortic valve stenosis. In this case, repositioning of the TRINITY resulted in optimal position without paravalvular leakage and with perfect function. The TRINITY heart valve is a repositionable and retrievable TAVI system. Both the implantation result and short-term clinical and haemodynamic outcome were excellent.

  12. Echocardiographic anatomy of the mitral valve in healthy dogs and dogs with myxomatous mitral valve disease.

    Science.gov (United States)

    Wesselowski, S; Borgarelli, M; Menciotti, G; Abbott, J

    2015-06-01

    To further characterize the echocardiographic anatomy of the canine mitral valve apparatus in normal dogs and in dogs affected by myxomatous mitral valve disease (MMVD). Twenty-two normal dogs and 60 dogs with MMVD were prospectively studied. The length (AMVL), width (AMVW) and area (AMVA) of the anterior mitral valve leaflet were measured in the control group and the affected group, as were the diameters of the mitral valve annulus in diastole (MVAd) and systole (MVAs). The dogs with MMVD were staged based on American College of Veterinary Internal Medicine (ACVIM) guidelines and separated into groups B1 and B2/C. All measurements were indexed to body weight based on empirically defined allometric relationships. There was a statistically significant relationship between all log10 transformed mitral valve dimensions and body weight. The AMVL, AMVW, AMVA, MVAd and MVAs were all significantly greater in the B2/C group compared to the B1 and control groups. The AMVW was also significantly greater in the B1 group compared to the control group. Interobserver % coefficient of variation (% CV) was mitral valve leaflet and the mitral valve annulus in the dog can be indexed to body weight based on allometric relationships. Preliminary reference intervals have been proposed over a range of body sizes. Relative to normal dogs, AMVL, AMVW, AMVA, MVAd and MVAs are greater in patients with advanced MMVD. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Balloon expandable transcatheter heart valves for native mitral valve disease with severe mitral annular calcification.

    Science.gov (United States)

    Guerrero, Mayra; Urena, Marina; Pursnani, Amit; Wang, Dee D; Vahanian, Alec; O'Neill, William; Feldman, Ted; Himbert, Dominique

    2016-06-01

    Patients with mitral annular calcification (MAC) have high surgical risk for mitral valve replacement due to associated comorbidities and technical challenges related to calcium burden, precluding surgery in many patients. Transcatheter mitral valve replacement (TMVR) with the compassionate use of balloon expandable aortic transcatheter heart valves has been used in this clinical scenario. The purpose of this review was to summarize the early experience including successes and failures reported. TMVR might evolve into an acceptable alternative for selected patients with severe MAC who are not candidates for conventional mitral valve surgery. However, this field is at a very early stage and the progress will be significantly slower than the development of transcatheter aortic valve replacement due to the complexity of the mitral valve anatomy and its pathology. Optimizing patient selection process by using multimodality imaging tools to accurately measure the mitral valve annulus and evaluate the risk of left ventricular outflow tract obstruction is essential to minimize complications. Strategies for treating and preventing left ventricular outflow tract obstruction are being tested. Similarly, carefully selecting candidates avoiding patients at the end of their disease process, might improve the overall outcomes.

  14. Compact UHV valve with field replaceable windows

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D. (Brookhaven National Lab., Upton, NY (United States)); Freeman, J. (VAT, Inc., Woburn, MA (United States)); Powell, F. (Luxel, Inc., Friday Harbor, WA (United States))

    1991-01-01

    There are many applications in synchrotron radiation research where window valves can be usefully employed. Examples include gas cells for monochromator calibration, filters for high order light rejection, and as vacuum isolation elements between machine and experimental vacua. Often these devices are fairly expensive, and have only fixed (ie non-removable) windows. The development of a new type of seal technology by VAT for their series 01 valves provides a gate surface which is free from obstructions due to internal mechanical elements. This feature allows a threaded recess to be machined into the gate to receive a removable window frame which can carry standard size Luxel thin film windows. The combination of these features results in a DN 40 (2.75in. conflat flange) valve which provides a clear aperture of 21mm diameter for the window material. 8 refs., 2 figs.

  15. Cardiac Rehabilitation After Heart Valve Surgery

    DEFF Research Database (Denmark)

    Pollmann, Agathe Gerwina Elena; Frederiksen, Marianne; Prescott, Eva

    2017-01-01

    PURPOSE: Evidence of the effect of cardiac rehabilitation (CR) after heart valve surgery is scarce, but nevertheless CR is recommended for this group of patients. Therefore, this study assessed the effect of CR on exercise capacity, cardiovascular risk factors, and long-term mortality and morbidity......, as well as predictors for enrolment in or failing to complete CR. METHODS: A review of medical records identified 250 patients who underwent heart valve surgery between January 2009 and August 2013. Of these, 211 patients eligible for CR were identified. Effect of CR was assessed by peak oxygen uptake.......58-15.06). CONCLUSIONS: CR after heart valve surgery improved exercise capacity and was associated with reduced morbidity. Elderly and ethnic minorities were less likely to attend or complete CR and deserve special attention....

  16. Piezogenic pedal papules with mitral valve prolapse

    Directory of Open Access Journals (Sweden)

    Cihan Altin

    2016-01-01

    Full Text Available Piezogenic pedal papules (PPP are herniations of subcutaneous adipose tissue into the dermis. PPP are skin-colored to yellowish papules and nodules on lateral surfaces of feet that typically become apparent when the patient stands flat on his/her feet. Some connective tissue diseases and syndromes have been reported in association with PPP. Mitral valve prolapse (MVP is a myxomatous degeneration of the mitral valve, characterized by the displacement of an abnormally thickened mitral valve leaflet into the left atrium during systole. MVP may be isolated or part of a heritable connective tissue disorder. PPP, which is generally considered as an isolated lesion, might be also a predictor of some cardiac diseases associated with connective tissue abnormalities such as MVP. A detailed systemic investigation including cardiac examination should be done in patients with PPP. Since in the literature, there are no case reports of association of PPP with MVP, we report these cases.

  17. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  18. Interlayer reliant magnetotransport in graphene spin valve

    Science.gov (United States)

    Iqbal, Muhammad Zahir; Hussain, Ghulam; Siddique, Salma; Iqbal, Muhammad Waqas

    2017-11-01

    Here the magnetotransport properties of vertical spin valve structures incorporating graphene (Gr), Gr/Au and Gr/Al2O3 intervening layers are elucidated. An in-plane magnetic field is obliquely applied to the device with the purpose to vary the relative magnetizations of ferromagnetic electrodes (Co and Ni). The relative magnetoresistance (MR) of Co/Gr/Ni is enhanced from ∼0.16% to 0.57% by simply passivating the bottom Ni electrode with thin Au film. On the other hand, depositing Al2O3 on the bottom ferromagnetic layer in such a spin valve junction not only increases the magnitude of MR (∼-0.52%) but also reverses its polarity. Furthermore, the linear current-voltage characteristics for graphene and graphene/Au spin valve devices specifies ohmic contact, while non-linear curves indicate tunneling behavior for graphene/Al2O3 device.

  19. Magneto-Seebeck effect in spin valves

    Science.gov (United States)

    Zhang, X. M.; Wan, C. H.; Wu, H.; Tang, P.; Yuan, Z. H.; Zhang, Q. T.; Zhang, X.; Tao, B. S.; Fang, C.; Han, X. F.

    2017-10-01

    The magneto-Seebeck (MS) effect, which is also called magneto-thermo-power, was observed in Co/Cu/Co and NiFe/Cu/Co spin valves. Their Seebeck coefficients in the parallel state were larger than those in the antiparallel state, and the MS ratio defined as (SAP -SP)/SP could reach -9% in our case. The MS effect originated not only from trivial giant magnetoresistance but also from spin current generated due to spin-polarized thermoelectric conductivity of ferromagnetic materials and subsequent modulation of the spin current by different spin configurations in spin valves. A simple Mott two-channel model reproduced a -11% MS effect for the Co/Cu/Co spin valves, qualitatively consistent with our observations. The MS effect could be applied for simultaneously sensing the temperature gradient and the magnetic field and also be possibly applied to determine spin polarization of thermoelectric conductivity and the Seebeck coefficient of ferromagnetic thin films.

  20. AeroValve Experimental Test Data Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, Mark W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-09-01

    This report documents the collection of experimental test data and presents performance characteristics for the AeroValve brand prototype pneumatic bidirectional solenoid valves tested at the Oak Ridge National Laboratory (ORNL) in July/August 2014 as part of a validation of AeroValve energy efficiency claims. The test stand and control programs were provided by AeroValve. All raw data and processing are included in the report attachments.

  1. Modal-Based Design Improvement of a Butterfly Valve Disc

    OpenAIRE

    Marius Draghiciu; Zoltan-Iosif Korka; Gilbert-Rainer Gillich

    2017-01-01

    The dynamic behaviour control of a butterfly valve is important because, when one of the valve disc natural frequency is close to the frequency of vortex shedding, which appears when the valve is fully open or partially closed, resonance may appear and vibration with significant amplitudes is generated. This paper presents an example by how the design of a butterfly valve disc can be improved by using a modal analysis performed by means of the finite element method. For this purpose, the rese...

  2. Numerical study of cavitating flow inside a flush valve

    OpenAIRE

    BAYEUL-LAINE, Annie-Claude; Simonet, Sophie; DUTHEIL, Daniel; Caignaert, Guy

    2011-01-01

    In water supply installations, noise pollution often occurs. As a basic component of a system, a flush valve may frequently be a source of noise and vibration generated by cavitation or high turbulence levels. During valve closing or valve opening, cavitation can be a problem. In order to decrease the noise and to improve the design inside a flush valve, some experimental and numerical analyses were carried out in our laboratories. These analyses led to some improvements in the de...

  3. Surgery for rheumatic tricuspid valve disease: a 30-year experience.

    Science.gov (United States)

    Bernal, José M; Pontón, Alejandro; Diaz, Begoña; Llorca, Javier; García, Iván; Sarralde, Aurelio; Diago, Carmen; Revuelta, José M

    2008-08-01

    This study was undertaken to assess factors influencing short- and long-term outcomes of surgery for rheumatic disease of the tricuspid valve. Between 1974 and 2005, a total of 328 consecutive patients (mean age 51.3 +/- 13.6 years) underwent tricuspid valve surgery for rheumatic disease. There were 12 cases of isolated tricuspid lesion, 199 of triple-valve disease, 114 of tricuspid and mitral valve disease, and 3 of aortic and tricuspid valve disease. Most patients (72%) had predominantly tricuspid regurgitation. Tricuspid valve prosthetic replacement was performed in 31 cases and valve repair in 297. In-hospital mortality was 7.6%. Late mortality was 52.1%, whereas the expected mortality of the Spanish population of the same age was 24.2%. Predictors of in-hospital mortality were male sex, isolated tricuspid lesion, moderate aortic insufficiency, postclamping time, and tricuspid valve replacement. Mean follow-up was 8.7 years (range 1-31 years). Follow-up was 98.9% complete. Predictors of late mortality were age, New York Heart Association functional class IV, postclamping time, and mitral valve replacement. In total, 114 patients required valve reoperation, but only 4 (3.5%) for isolated tricuspid valve dysfunction. At 30 years, actuarial survival was 12.1% +/- 4.4%, actuarial freedom from reoperation was 27.5% +/- 5.8%, and actuarial freedom from valve-related complications was 2.0% +/- 1.3%. Organic tricuspid valve disease associated with rheumatic mitral or aortic lesions increases hospital and late mortality, but valve repair compared favorably with valve replacement. Long-term results may be considered acceptable for otherwise incurable valve disease.

  4. Morphological assessment of sucrose preservation for porcine heart valves.

    OpenAIRE

    Drury, P J; Olsen, E G; Ross, D N

    1982-01-01

    Porcine aortic valves stored in various concentrations of sucrose (50-80%) for up to 52 weeks were examined both histologically and by electron microscopy. The valves were compared with porcine aortic valves stored in a nutrient and antibiotic medium for 12 weeks. Overall preservation was better in those porcine valves stored in sucrose solution than in nutrient and antibiotic medium, the best preservation being in 50% sucrose. Despite wide separation of collagen at that concentration seen on...

  5. T Cell exhaustion in protozoan disease

    Science.gov (United States)

    Gigley, Jason P.; Bhadra, Rajarshi; Moretto, Magali M.; Khan, Imtiaz A.

    2012-01-01

    Protozoan parasites cause severe morbidity and mortality in humans worldwide, especially in developing countries where access to chemotherapeutic agents is limited. Although parasites initially evoke a robust immune response, subsequent immunity fails to clear infection, ultimately leading to the chronic stage. This enigmatic situation was initially addressed in chronic viral models, where T cells lose their function, a phenomenon referred to as ’exhaustion‘. However, recent studies demonstrate that this paradigm can be extended to protozoan diseases as well, albeit with notable differences. These studies have revealed that T cell responses generated against Toxoplasma gondii, Plasmodium sp. and Leishmania sp. can become dysfunctional. This Review discusses T cell exhaustion in parasitic infection, mechanisms of development, and a possible role in disease outcome. PMID:22832368

  6. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  7. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  8. [Quality in aortic valve replacement--how good have hybrid valves have to be?].

    Science.gov (United States)

    Aicher, D; Groesdonk, H V; Schäfers, H-J

    2009-10-01

    The current enthusiasm with the development of catheter-based aortic valve replacement suggests a critical appraisal of the quality of conventional techniques. Currently surgical treatment of diseased aortic valves includes different methods that can be employed with a low risk. Risk prediction is difficult, the Euroscore largely overestimates mortality. By comparison, there is no evidence that the risk of implantation is reduced by catheter-based implantation. Specific complications (stroke, AV-block, perivalvular leak) are more frequent compared to conventional replacement. Despite the current enthusiasm over the feasibility of catheter-based implantation of hybrid aortic valves they should still be used cautiously. Georg Thieme Verlag KG Stuttgart, New York.

  9. Assessment of slurry pressure letdown valve and slurry block valve technology for direct coal liquefaction demonstration and pioneer commercial plants

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, R.P.

    1984-10-01

    This report examines the status of the technology of high pressure slurry letdown valves and slurry block valves in coal liquefaction service. All of the demonstration and pioneer commercial direct liquefaction plant designs call for the use of high pressure slurry letdown valves for flow control and slurry block valves for flow isolation. Successful performance and reliability of these valves is a serious concern because of the severity of the process streams and the limited experience and performance data on these valves under such conditions. The objectives of this report are: (1) to examine the existing data base on these valves from the four major direct coal liquefaction pilot plants in the US, (2) to present the recommendations from the pilot plant experience, (3) to examine the specifications for the letdown and block valves in the demonstration/pioneer commercial designs, and (4) to identify the scale-up issues, data gaps, and development and testing needs. 23 references, 20 figures, 7 tables.

  10. Remote operated valves - the Bolivian approach

    Energy Technology Data Exchange (ETDEWEB)

    Cuellar, O.; Arce, G.; Blanco, E.; Collazos, A.; Chavarria, E. [Transredes S.A., Transporte de Hidrocarburos, La Paz (Bolivia)

    2005-07-01

    For pipeline operators, the Remote Operated Valves (ROV) are tools to isolate pipe segments and contain any potential spill and they are also useful tools to provide data on operating conditions. Projects and articles about the locations and site layouts were developed to install Remote Operated Valves and the criteria for their use; each location has its own environmental, social and logistical particulars. This article describes the approach used to install ROV in Bolivia and the final design installed discussions and lessons learned about the: criteria to define the location, layout equipment installed and shelter and particulars of the location. (author)

  11. Left Ventricular Pseudoaneurysm after Valve Replacement

    Directory of Open Access Journals (Sweden)

    Jun Ho Lee

    2015-02-01

    Full Text Available We present a case of left ventricular pseudoaneurysm, which is a very rare and fatal complication of cardiac procedures such as mitral valve replacement. A 55-year-old woman presented to the Department of Thoracic and Cardiovascular Surgery at Hanyang University Seoul Hospital with chest pain. Ten years prior, the patient had undergone double valve replacement due to aortic regurgitation and mitral steno-insufficiency. Surgical repair was successfully performed using a prosthetic pericardial patch via a left lateral thoracotomy.

  12. The serpentine mitral valve and cerebral embolism

    Directory of Open Access Journals (Sweden)

    Ker James

    2011-02-01

    Full Text Available Abstract Valvular strands, well-delineated filiform masses, attached to cardiac valve edges are associated with cerebral embolism and stroke. Strokes, caused by emboli from valvular strands, tend to occur among younger persons. In this case report a valvular strand, giving a peculiar serpentine appearance to the mitral valve is described. This mitral valvular strand was the only explanation for an episode of cerebral embolism, presenting with a transient right sided hemiparesis. It is proposed that a randomized study involving combined treatment with aspirin and clopidogrel is warranted in young patients with valvular strands, presenting with a first episode of cerebral embolism.

  13. Torque limited drive for manual valves

    Science.gov (United States)

    Elliott, Philip G.; Underwood, Daniel E.

    1989-01-01

    The present invention is directed to a torque-limiting handwheel device for preventing manual valves from being damaged due to the application of excessive torque during the opening or closing operation of the valves. Torque can only be applied when ridges in the handwheel assembly engage in channels machined in the face of the baseplate. The amount of torque required for disengagement of the ridges from the channels is determined by the force exerted by various Bellville springs and the inclination of the side faces of the channels.

  14. Computer tomographic findings in mitral valve disease

    Energy Technology Data Exchange (ETDEWEB)

    Heuser, L.; Neufang, K.F.R.; Jansen, W.

    1984-04-01

    In 38 patients suffering from mitral valve disease the findings of cardiac CT scans were compared to the results of echocardiographic, standard roentgenographic, and cineangiocardiographic studies as well as to intraoperative and histological findings. CT proved to be superior to the other imaging modalities in detecting mitral calcifications and in demonstrating the morphological changes, but cannot replace cardiac catheterization as it does not yield haemodynamic data. The indication for CT in mitral valve disease therefore is restricted to cases with extremely enlarged left atria in which the other methods do not provide satisfactory visualization, and to patients with suspected intracavitary thrombus or tumor. 8 figs.

  15. Multimodality Imaging of Heart Valve Disease

    Energy Technology Data Exchange (ETDEWEB)

    Rajani, Ronak, E-mail: Dr.R.Rajani@gmail.com [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom); Khattar, Rajdeep [Department of Cardiology, Royal Brompton Hospital, London (United Kingdom); Chiribiri, Amedeo [Divisions of Imaging Sciences, The Rayne Institute, St. Thomas' Hospital, London (United Kingdom); Victor, Kelly; Chambers, John [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom)

    2014-09-15

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses.

  16. Autonomous valve for detection of biopolymer degradation

    DEFF Research Database (Denmark)

    Keller, Stephan Urs; Noeth, Nadine-Nicole; Fetz, Stefanie

    2009-01-01

    We present a polymer microvalve that allows the detection of biopolymer degradation without the need of external energy. The valve is based on a polymer container filled with a colored marker solution and closed by a thin lid. This structure is covered by a film of poly(L-lactide) and degradation...... of the biopolymer triggers the release of the color which is detected visually. The autonomous valve has potential for the fast testing of biopolymer degradation under various environmental conditions or by specific enzymes....

  17. Pregnancy Outcomes in Women With Aortic Valve Substitutes

    NARCIS (Netherlands)

    Heuvelman, Helena J.; Arabkhani, Bardia; Cornette, Jerome M. J.; Pieper, Petronella G.; Bogers, Ad J. J. C.; Takkenberg, Johanna J. M.; Roos-Hesselink, Jolien W.

    2013-01-01

    Young women who require aortic valve replacement need information on the potential cardiac and obstetric complications of pregnancy for the different valve substitutes available. We, therefore, assessed the pregnancy outcomes in women who had received an autograft, homograft, or mechanical valve in

  18. 46 CFR 61.05-20 - Boiler safety valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping... INSPECTIONS Tests and Inspections of Boilers § 61.05-20 Boiler safety valves. Each safety valve for a drum, superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10. ...

  19. The Bundle of His in Prosthetic Heart Valve Replacement*

    African Journals Online (AJOL)

    1973-01-27

    Jan 27, 1973 ... sudden deaths which occur following heart valve replace- ment. In our local cardiac surgery unit at Groote Schuur. Hospital, the hospital mortality rate for aortic valve replacement with the University of Cape Town (VeT) aortic valve prosthesis between March 1963 and October. 1968, was 120. 0 according to ...

  20. Intermittent intravalvar regurgitation of a mechanical aortic valve ...

    African Journals Online (AJOL)

    Mechanical prosthetic valve regurgitation may be either periprosthetic or intraprosthetic. The later is usually mild, occurring in the majority of normally functioning valves and is due to the 'regurgitant flow' closing the valve. An unusual case is reported of intermitent intraprosthetic regurgitation through a normally functioning ...

  1. Low-power piezoelectric micro-machined valve

    Science.gov (United States)

    Gianchandani, Yogesh B. (Inventor); Nellis, Gregory Francis (Inventor); Klein, Sanford A. (Inventor); Park, John Moon (Inventor); Evans, Allan Thomas (Inventor); Taylor, Ryan (Inventor); Brosten, Tyler R. (Inventor)

    2010-01-01

    A piezoelectric microvalve employs a valve element formed of hermetically sealed and opposed plates flexed together by a cross axis piezoelectric element. Large flow modulation with small piezoelectric actuator displacement is obtained by perimeter augmentation of the valve seat which dramatically increases the change in valve flow area for small deflections.

  2. 49 CFR 230.52 - Water glass valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Water glass valves. 230.52 Section 230.52... Water Glasses and Gauge Cocks § 230.52 Water glass valves. All water glasses shall be equipped with no more than two valves capable of isolating the water glass from the boiler. They shall also be equipped...

  3. The Heimlich Valve for Pleural Cavity Drainage | Makanga | Annals ...

    African Journals Online (AJOL)

    One-way valve systems such as the Heimlich valve are small, portable apparatus that allow regulation of fluid flow and require minimal nursing care other than daily charting. Methods: A retrospective descriptive analysis of all chest drains connected to a Heimlich valve between January 2009 and December 2012. Data on ...

  4. 49 CFR 192.181 - Distribution line valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution line valves. 192.181 Section 192.181 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... line valves. (a) Each high-pressure distribution system must have valves spaced so as to reduce the...

  5. 46 CFR 154.546 - Excess flow valve: Closing flow.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Excess flow valve: Closing flow. 154.546 Section 154.546... and Process Piping Systems § 154.546 Excess flow valve: Closing flow. (a) The rated closing flow of vapor or liquid cargo for an excess flow valve must be specially approved by the Commandant (CG-522). (b...

  6. The Warm, Rich Sound of Valve Guitar Amplifiers

    Science.gov (United States)

    Keeports, David

    2017-01-01

    Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier…

  7. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance: Transmission lines. 192.745... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.745 Valve maintenance: Transmission lines. (a) Each transmission line valve that might be required during any emergency...

  8. Perioperative anticoagulation for children with prosthetic mechanical valves

    OpenAIRE

    Grech, Victor E.; Rees, Philip G.

    2000-01-01

    The insertion of a mechanical heart valve predisposes to thrombosis and embolism, and for this reason, individuals with mechanical valves who undergo dental/surgical procedures must take special precautions. In this article, we illustrate a protocol for anticoagulation during such procedures in individuals with mechanical valves.

  9. Transcatheter Pulmonary Valve Replacement by Hybrid Approach Using a Novel Polymeric Prosthetic Heart Valve: Proof of Concept in Sheep

    OpenAIRE

    Ben Zhang; Xiang Chen; Tong-yi Xu; Zhi-gang Zhang; Xin Li; Lin Han; Zhi-yun Xu

    2014-01-01

    Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmo...

  10. 46 CFR 182.430 - Engine exhaust pipe installation.

    Science.gov (United States)

    2010-10-01

    ... installation. (a) The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection... steel or equivalent bulkhead in way of a penetration and a fiberglass wet exhaust pipe may be fiberglassed to a fiberglass reinforced plastic bulkhead if suitable arrangements are provided to relieve the...

  11. 46 CFR 63.25-7 - Exhaust gas boilers.

    Science.gov (United States)

    2010-10-01

    ... drum type exhaust gas steam boiler must have a feed water control system. The system must automatically... 46 Shipping 2 2010-10-01 2010-10-01 false Exhaust gas boilers. 63.25-7 Section 63.25-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS...

  12. 44 CFR 5.58 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Exhaustion of administrative remedies. 5.58 Section 5.58 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY... Exhaustion of administrative remedies. Any person making a request to FEMA for records under this part shall...

  13. A Numerical and Experimental Study of Local Exhaust Capture Efficiency

    DEFF Research Database (Denmark)

    Madsen, U.; Breum, N. O.; Nielsen, Peter Vilhelm

    1993-01-01

    Direct capture efficiency of a local exhaust system is defined by introducing an imaginary control box surrounding the contaminant source and the exhaust opening. The imaginary box makes it possible to distinguish between contaminants directly captured and those that escape. Two methods...

  14. 33 CFR 331.12 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Exhaustion of administrative remedies. 331.12 Section 331.12 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ADMINISTRATIVE APPEAL PROCESS § 331.12 Exhaustion of administrative remedies. No...

  15. 25 CFR 67.12 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Exhaustion of administrative remedies. 67.12 Section 67.12 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR TRIBAL GOVERNMENT PREPARATION OF A ROLL OF INDEPENDENT SEMINOLE INDIANS OF FLORIDA § 67.12 Exhaustion of administrative remedies. The...

  16. 29 CFR 4003.7 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Exhaustion of administrative remedies. 4003.7 Section 4003.7 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION GENERAL RULES FOR ADMINISTRATIVE REVIEW OF AGENCY DECISIONS General Provisions § 4003.7 Exhaustion of administrative...

  17. 43 CFR 4.314 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Exhaustion of administrative remedies. 4.314 Section 4.314 Public Lands: Interior Office of the Secretary of the Interior DEPARTMENT HEARINGS... Applicable to Proceedings on Appeal Before the Interior Board of Indian Appeals § 4.314 Exhaustion of...

  18. Emotional exhaustion may trigger cut in working hours

    NARCIS (Netherlands)

    Koppes, L.

    2012-01-01

    Researchers in the Netherlands have been examining to what extent workers are modifying their hours to cope with high levels of work-related emotional exhaustion. Findings reveal that most full-time employees would prefer a cut in their hours, with those reporting emotional exhaustion wanting a

  19. 5 CFR 1208.21 - VEOA exhaustion requirement.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false VEOA exhaustion requirement. 1208.21 Section 1208.21 Administrative Personnel MERIT SYSTEMS PROTECTION BOARD ORGANIZATION AND PROCEDURES... THE VETERANS EMPLOYMENT OPPORTUNITIES ACT VEOA Appeals § 1208.21 VEOA exhaustion requirement. Before...

  20. Telomeres and HIV-1 infection: in search of exhaustion

    NARCIS (Netherlands)

    Wolthers, K. C.; Miedema, F.

    1998-01-01

    Telomere length analysis could be helpful in determining if exhaustion and replicative senescence are involved in HIV-1 pathogenesis. Evidence that CD8+ T cells have shorter telomeres may point towards an increased turnover of CD8+ T cells and exhaustion of the CD8+ T-cell responses in HIV-1

  1. 29 CFR 4901.17 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Exhaustion of administrative remedies. 4901.17 Section 4901.17 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION INTERNAL AND... Procedure for Formal Requests § 4901.17 Exhaustion of administrative remedies. If the disclosure officer...

  2. 45 CFR 617.15 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Exhaustion of administrative remedies. 617.15 Section 617.15 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE... ASSISTANCE FROM NSF § 617.15 Exhaustion of administrative remedies. (a) A complainant may file a civil action...

  3. Exhaustion in University Students and the Effect of Coursework Involvement

    Science.gov (United States)

    Law, Daniel W.

    2007-01-01

    Although researchers have examined exhaustion extensively in occupational studies, this work-specific variable--despite its widespread acceptance and negative outcomes--has received little attention in regard to university students and their coursework. Objective: The author examined the severity of exhaustion in students and the relationship…

  4. 7 CFR 400.56 - Administrative appeal exhaustion.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Administrative appeal exhaustion. 400.56 Section 400.56 Agriculture Regulations of the Department of Agriculture (Continued) FEDERAL CROP INSURANCE... Administrative appeal exhaustion. The insured may appeal the approved APH yield in accordance with the procedures...

  5. 7 CFR 400.453 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Exhaustion of administrative remedies. 400.453 Section 400.453 Agriculture Regulations of the Department of Agriculture (Continued) FEDERAL CROP INSURANCE...-Compliance § 400.453 Exhaustion of administrative remedies. All administrative remedies contained herein or...

  6. 28 CFR 32.8 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Exhaustion of administrative remedies. 32.8 Section 32.8 Judicial Administration DEPARTMENT OF JUSTICE PUBLIC SAFETY OFFICERS' DEATH, DISABILITY, AND EDUCATIONAL ASSISTANCE BENEFIT CLAIMS General Provisions § 32.8 Exhaustion of administrative...

  7. Relations between Teachers' Emotional Exhaustion and Students' Educational Outcomes

    Science.gov (United States)

    Arens, A. Katrin; Morin, Alexandre J. S.

    2016-01-01

    Studies investigating the effects of emotional exhaustion among teachers have primarily focused on its relations with teacher-related outcome variables but little research has been done for examining its relations with student outcomes. Therefore, this study examines the relations between teachers' emotional exhaustion and educational outcomes…

  8. Unemployment Benefit Exhaustion: Incentive Effects on Job-Finding Rates

    Science.gov (United States)

    Filges, Trine; Geerdsen, Lars Pico; Knudsen, Anne-Sofie Due; Jørgensen, Anne-Marie Klint

    2015-01-01

    Purpose: This systematic review studied the impact of exhaustion of unemployment benefits on the exit rate out of unemployment and into employment prior to benefit exhaustion or shortly thereafter. Method: We followed Campbell Collaboration guidelines to prepare this review, and ultimately located 12 studies for final analysis and interpretation.…

  9. 26 CFR 301.7430-1 - Exhaustion of administrative remedies.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Exhaustion of administrative remedies. 301.7430-1 Section 301.7430-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY... the United States § 301.7430-1 Exhaustion of administrative remedies. (a) In general. Section 7430(b...

  10. 49 CFR 229.43 - Exhaust and battery gases.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Exhaust and battery gases. 229.43 Section 229.43... § 229.43 Exhaust and battery gases. (a) Products of combustion shall be released entirely outside the... conditions. (b) Battery containers shall be vented and batteries kept from gassing excessively. ...

  11. 40 CFR 86.211-94 - Exhaust gas analytical system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Exhaust gas analytical system. 86.211-94 Section 86.211-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... New Medium-Duty Passenger Vehicles; Cold Temperature Test Procedures § 86.211-94 Exhaust gas...

  12. Diesel Engine Exhaust: Basis for Occupational Exposure Limit Value.

    Science.gov (United States)

    Taxell, Piia; Santonen, Tiina

    2017-08-01

    Diesel engines are widely used in transport and power supply, making occupational exposure to diesel exhaust common. Both human and animal studies associate exposure to diesel exhaust with inflammatory lung effects, cardiovascular effects, and an increased risk of lung cancer. The International Agency for Research on Cancer has evaluated diesel exhaust as carcinogenic to humans. Yet national or regional limit values for controlling occupational exposure to diesel exhaust are rare. In recent decades, stricter emission regulations have led to diesel technologies evolving significantly, resulting in changes in exhaust emissions and composition. These changes are also expected to influence the health effects of diesel exhaust. This review provides an overview of the current knowledge on the health effects of diesel exhaust and the influence of new diesel technologies on the health risk. It discusses the relevant exposure indicators and perspectives for setting occupational exposure limit values for diesel exhaust, and outlines directions for future research. The review is based on a collaborative evaluation report by the Nordic Expert Group for Criteria Documentation of Health Risks from Chemicals and the Dutch Expert Committee on Occupational Safety. © The Author 2017. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  13. Effect of diesel generator exhaust pollutants on growth of Vinca ...

    African Journals Online (AJOL)

    The effects of exhaust pollutants of generator on root and shoot length, root and shoot weight, number of leaflets and leaf area, leaf and total plant dry weight of Vinca rosea and Ruellia tuberosa were studied. The treatment of exhaust pollutants produced significant effects on root, shoot growth, number of leaflet and leaf ...

  14. Diesel Exhaust in Miners Study: Q&A

    Science.gov (United States)

    The Diesel Exhaust in Miners Study was designed to evaluate the risk of death associated with diesel exhaust exposure, particularly as it may relate to lung cancer. The researchers observed increased risk for lung cancer death with increasing levels of ex

  15. PHYSICAL AND NUMERICAL MODELING OF ASD EXHAUST DISPERSION AROUND HOUSES

    Science.gov (United States)

    The report discusses the use of a wind tunnel to physically model the dispersion of exhaust plumes from active soil depressurization (ASD) radon mitigation systems in houses. he testing studied the effects of exhaust location (grade level vs. above the eave), as house height, roo...

  16. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  17. Modeling and Investigation of Electromechanical Valve Train Actuator at simulated Pressure conditions

    DEFF Research Database (Denmark)

    Habib, Tufail

    2012-01-01

    In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about investig......In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about...

  18. Concomitant mitral valve surgery with aortic valve replacement: a 21-year experience with a single mechanical prosthesis

    Directory of Open Access Journals (Sweden)

    Sidhu Pushpinder

    2007-05-01

    Full Text Available Abstract Background Long-term survival for combined aortic and mitral valve replacement appears to be determined by the mitral valve prosthesis from our previous studies. This 21-year retrospective study assess long-term outcome and durability of aortic valve replacement (AVR with either concomitant mitral valve replacement (MVR or mitral valve repair (MVrep. We consider only a single mechanical prosthesis. Methods Three hundred and sixteen patients underwent double valve replacement (DVR (n = 273 or AVR+MVrep (n = 43, in the period 1977 to 1997. Follow up of 100% was achieved via telephone questionnaire and review of patients' medical records. Actuarial analysis of long-term survival was determined by Kaplan-Meier method. The Cox regression model was used to evaluate potential predictors of mortality. Results There were seventeen cases (5.4% of early mortality and ninety-six cases of late mortality. Fifteen-year survival was similar in both groups at 44% and 57% for DVR and AVR+MVrep respectively. There were no significant differences in valve related deaths, anticoagulation related complications, or prosthetic valve endocarditis between the groups. There were 6 cases of periprosthetic leak in the DVR group. Sex, pre-operative mitral and aortic valve pathology or previous cardiac surgery did not significantly affect outcome. Conclusion The mitral valve appears to be the determinant of survival following double valve surgery and survival is not significantly influenced by mitral valve repair.

  19. 30 CFR 250.445 - What are the requirements for kelly valves, inside BOPs, and drill-string safety valves?

    Science.gov (United States)

    2010-07-01

    ... motor and use drill pipe instead of a kelly, you must install one kelly valve above, and one strippable kelly valve below, the joint of drill pipe used in place of a kelly; (d) On a top-drive system equipped..., inside BOPs, and drill-string safety valves? 250.445 Section 250.445 Mineral Resources MINERALS...

  20. Muscle interstitial potassium kinetics during intense exhaustive exercise

    DEFF Research Database (Denmark)

    Nordsborg, Nikolai; Mohr, Magni; Pedersen, Lasse Dannemann

    2003-01-01

    Interstitial K+ ([K+]i) was measured in human skeletal muscle by microdialysis during exhaustive leg exercise, with (AL) and without (L) previous intense arm exercise. In addition, the reproducibility of the [K+]i determinations was examined. Possible microdialysis-induced rupture of the sarcolemma...... was assessed by measurement of carnosine in the dialysate, because carnosine is only expected to be found intracellularly. Changes in [K+]i could be reproduced, when exhaustive leg exercise was performed on two different days, with a between-day difference of approximately 0.5 mM at rest and 1.5 m......M at exhaustion. The time to exhaustion was shorter in AL than in L (2.7 +/- 0.3 vs. 4.0 +/- 0.3 min; P exhaustion (11.9 +/- 0.5 vs. 10.3 +/- 0.6 mM; P...

  1. A new concept for exhaust diffusers of altitude test cells

    Science.gov (United States)

    Parikh, P. G.; Sarohia, V.

    1984-01-01

    A new exhaust diffuser concept for jet engine altitude test cells which greatly reduces operating power and cost requirements for exhausters is discussed. The concept utilizes the capture duct as an efficient diffuser only, while evacuating the secondary air via a separate path using an auxiliary suction system. Implementation of the concept would reduce the peak exhauster power requirement during a TF-30 altitude test by 48 percent and the overall exhaust power cost of the test program by 41 percent. The design accommodates various engine sizes and can achieve optimum pressure recovery performance during both A/B and IRP modes of engine operation. The pressure recovery performance of the proposed exhaust diffusers does not deteriorate with increasing cooling air fraction. The disadvantages of the proposed scheme are: increased mechanical complexity of the extended variable geometry diffuser duct and the need for an auxiliary suction system for evacuating cell-cooling air.

  2. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  3. Mitraclip Followed by Surgical Aortic Valve Replacement: Hybrid Techniques for Regurgitant Aortic and Mitral Valve Disease.

    Science.gov (United States)

    Eudailey, Kyle; Hamid, Nadira; Hahn, Rebecca T; Kodali, Susheel; Gray, William; George, Isaac

    2016-08-01

    With the advent of percutaneous valve interventions, the landscape for management of high-risk valve replacement and repair has changed dramatically. Transcatheter valve repair/replacement techniques can be used in conjunction with open surgery to facilitate a hybrid approach in patients with multivalve disease. We present a case of staged hybrid valve repair followed by surgical replacement for a high-risk patient with mitral regurgitation and aortic regurgitation. This case illustrates the effectiveness of the staged hybrid approach for high-risk patients with incomplete transcatheter options. We expect these techniques to play an increasingly larger role in the treatment algorithm for high-risk multivalve disease. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. 42 CFR 84.137 - Inhalation and exhalation valves; check valves; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... distortion. (b) Exhalation valves shall be: (1) Protected against damage and external influence; and (2... or in the hose fitting near the facepiece of all Type A, AE, B, and BE supplied-air respirators. ...

  5. Transvalvular pressure gradients for different methods of mitral valve repair: only neochordoplasty achieves native valve gradients.

    Science.gov (United States)

    Jahren, Silje Ekroll; Hurni, Samuel; Heinisch, Paul Philipp; Winkler, Bernhard; Obrist, Dominik; Carrel, Thierry; Weber, Alberto

    2018-02-01

    Many surgical and interventional methods are available to restore patency for patients with degenerative severe mitral valve regurgitation. Leaflet resection and neochordoplasty, which both include ring annuloplasty, are the most frequently performed techniques for the repair of posterior mitral leaflet flail. It is unclear which technique results in the best haemodynamics. In this study, we investigated the effect of different mitral valve reconstruction techniques on mitral valve haemodynamics and diastolic transvalvular pressure gradient in an ex vivo porcine model. Eight porcine mitral valves were tested under pulsatile flow conditions in an in vitro pulsatile flow loop for haemodynamic quantification. Severe acute posterior mitral leaflet flail was created by resecting the posterior marginal chorda. The acute mitral valve regurgitation was corrected using 4 different repair techniques, in each valve, in a strictly successive order: (i) neochordoplasty with polytetrafluoroethylene sutures alone and (ii) with ring annuloplasty, (iii) edge-to-edge repair and (iv) triangular leaflet resection, both with ring annuloplasty. Valve haemodynamics were measured and quantified for all valve configurations (native, rupture and each surgical reconstruction). The results were analysed using a validated statistical linear mixed model, and the P-values were calculated using a 2-sided Wald test. All surgical reconstruction techniques were able to sufficiently correct the acute mitral valve regurgitation. Neochordoplasty without ring annuloplasty was the only reconstruction technique that resulted in haemodynamic properties similar to the native mitral valve (P-values from 0.071 to 0.901). The diastolic transvalvular gradient remained within the physiological range for all reconstructions but was significantly higher than in the native valve for neochordoplasty with ring annuloplasty (P < 0.000), edge-to-edge repair (P < 0.000) and leaflet resection (P < 0

  6. Effectiveness of rivaroxaban for thromboprophylaxis of prosthetic heart valves in a porcine heterotopic valve model.

    Science.gov (United States)

    Greiten, Lawrence E; McKellar, Stephen H; Rysavy, Joseph; Schaff, Hartzell V

    2014-05-01

    Warfarin is used to reduce the risk of stroke and thromboembolic complications in patients with mechanical heart valves. Yet, despite frequent blood testing, its poor pharmacokinetic and pharmacodynamic profiles often result in variable therapeutic levels. Rivaroxaban is a direct competitive factor Xa inhibitor that is taken orally. It inhibits the active site of factor Xa without the need for the cofactor antithrombin, and thus, its mechanism of action is differentiated from that of the fractionated heparins and indirect factor Xa inhibitors. No in vivo data exist regarding the effectiveness of rivaroxaban in preventing thromboembolic complications of mechanical heart valves. We tested the hypothesis that rivaroxaban is as effective as enoxaparin for thromboprophylaxis of mechanical valves that use a previously described heterotopic aortic valve porcine model. A modified bileaflet mechanical valved conduit that bypassed the native, ligated descending thoracic aorta was implanted into 30 swine. Postoperatively, the animals were randomly assigned to groups receiving no anticoagulation (n = 10), enoxaparin at 2 mg/kg subcutaneously twice daily (n = 10) or rivaroxaban at 2 mg/kg orally twice daily (n = 10). The amount of valve thrombus was measured on post-implantation day 30 as the primary end point. Quantitative evaluation of radiolabelled platelet deposition on the valve prostheses was done and embolic and haemorrhagic events were measured as secondary end points. Animals with no anticoagulation had a thrombus mean of 759.9 mg compared with 716.8 mg with enoxaparin treatment and 209.6 mg with rivaroxaban treatment (P = 0.05 for enoxaparin vs rivaroxaban). Similarly, the mean number of platelets deposited on the valve prosthesis was lower in the rivaroxaban group (6.13 × 10(9)) than in the enoxaparin group (3.03 × 10(10)) (P = 0.03). In this study, rivaroxaban was more effective than enoxaparin for short-term thromboprophylaxis of mechanical valve prosthetics in

  7. Predictors of permanent pacemaker implantation after transfemoral aortic valve implantation with the Lotus valve.

    Science.gov (United States)

    Keßler, Mirjam; Gonska, Birgid; Seeger, Julia; Rottbauer, Wolfgang; Wöhrle, Jochen

    2017-10-01

    Permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation is of high clinical relevance, but PPMI rates differ widely between valve types. Although the Lotus valve can be repositioned, reported rates for PPMI are high. The predictors of PPMI after Lotus valve implantation have not been defined yet. We analyzed the impact of preexisting conduction disturbances, depth of implantation, oversizing, and amount of calcification on PPMI in 216 patients with severe symptomatic aortic stenosis underdoing Lotus valve implantation. PPMI was required in 39.8% of patients. Patients with need for PPMI compared with patients without need for PPMI had more often the following criteria: male gender (P=.035); preprocedural right bundle-branch block (RBBB) (16.3% vs 0, P<.001); atrioventricular (AV) block first degree (26.7% vs 10.1%, P=.004); higher calcium volume of the left coronary cusp (63.1±87.5 mm(3) vs 42.8±49.3 mm(3), P=.05); and deeper valve implantation at right coronary (P=.011), noncoronary (P=.026), and left coronary (P=.012) position. Oversizing in relation to annulus and left ventricular outflow tract did not have an impact on need for PPMI. By multiple regression analysis, preprocedural AV block first degree (P=.005), RBBB (P<.001), and depth of implantation (P=.006) were independent risk factors for need of PPMI. In patients with severe aortic stenosis receiving transfemoral Lotus valve, preexisting AV block first degree, RBBB, and implantation depth are independent predictors of PPMI, highlighting the importance of careful valve positioning. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. 3D Printed Trileaflet Valve Conduits Using Biological Hydrogels and Human Valve Interstitial Cells

    OpenAIRE

    Duan, Bin; Kapetanovic, Edi; Hockaday, Laura A.; Butcher, Jonathan T.

    2013-01-01

    Tissue engineering has great potential to provide a functional de novo living valve replacement capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, 3D bioprinting enables deposition of cells and hydrogels into 3D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach is however constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not know...

  9. Characterization of Aortic Valve Closure Artifact During Outflow Tract Mapping: Correlation With Hemodynamics and Mechanical Valves.

    Science.gov (United States)

    Romero, Jorge; Ajijola, Olujimi; Shivkumar, Kalyanam; Tung, Roderick

    2017-06-01

    Premature ventricular contractions originating in the left ventricle outflow tract represent a significant subgroup of patients referred for catheter ablation. Mechanical artifacts from aortic valve leaflet motion may be observed during mapping, although the incidence and characteristics have not been reported. Twenty-eight consecutive patients with left ventricle outflow tract premature ventricular contraction were included. Electric signals recorded on the ablation catheter not coincident with atrial or ventricular depolarization were analyzed on the recording system. Correlation with invasive hemodynamic aortic pressure tracings was performed. Additionally, 4 patients with mechanical aortic valves, who underwent scar-related ventricular tachycardia ablation, were analyzed to correlate the timing of the observed artifacts with native aortic valves. Aortic valve artifact was observed while mapping within the coronary cusps in 11 patients (39%; 73% men; age, 41±25 years; left ventricular ejection fraction 49±16%) with high incidence from the left coronary cusp. This artifact was consistently observed with timing coincident with the terminal portion of the T wave. The average interval between the end of the T wave and the aortic valve artifact was 19±37 ms. The duration of the aortic valve artifact was 39±8 ms with amplitude of 0.12±0.07 mV (range, 0.06-0.36 mV). In patients referred for left ventricle outflow tract premature ventricular contraction ablation, an aortic valve closure artifact is observed in up to one third of cases during mapping within the aortic cusps. The timing of this artifact correlates with invasive hemodynamics and mechanical aortic valve artifacts. Recognition of this physiological phenomenon is useful when assigning near-field activation. © 2017 American Heart Association, Inc.

  10. The warm, rich sound of valve guitar amplifiers

    Science.gov (United States)

    Keeports, David

    2017-03-01

    Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier adds harmonics to an input sound. While a moderately overdriven valve amplifier produces strong even harmonics that enhance a sound, an overdriven transistor amplifier creates strong odd harmonics that can cause dissonance. The functioning of a triode valve explains its creation of even and odd harmonics. Music production software enables the examination of both the wave shape and the harmonic content of amplified sounds.

  11. Three-dimensional analysis of partially open butterfly valve flows

    Energy Technology Data Exchange (ETDEWEB)

    Huang, C.; Kim, R.H. [Univ. of North Carolina, Charlotte, NC (United States). Dept. of Mechanical Engineering and Engineering Science

    1996-09-01

    A numerical simulation of butterfly valve flows is a useful technique to investigate the physical phenomena of the flow field. A three-dimensional numerical analysis was carried out on incompressible fluid flows in a butterfly valve by using FLUENT, which solves difference equations. Characteristics of the butterfly valve flows at different valve disk angles with a uniform incoming velocity were investigated. Comparisons of FLUENT results with other results, i.e., experimental results, were made to determine the accuracy of the employed method. Results of the three-dimensional analysis may be useful in the valve design.

  12. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  13. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  14. Diaphragms in air-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Groeger, J.E.

    1996-12-01

    The author will present current issues related to diaphgrams in air-operated valves. Altran Materials Engineering, Inc., often performs root-cause analyses for nuclear power plant owners. The author will discuss various analyses that have been performed or are currently underway.

  15. Ventriculopleural shunting with new technology valves.

    Science.gov (United States)

    Martínez-Lage, J F; Torres, J; Campillo, H; Sanchez-del-Rincón, I; Bueno, F; Zambudio, G; Poza, M

    2000-12-01

    Ventriculoperitoneal shunting constitutes the standard procedure for draining cerebrospinal fluid (CSF) in children with hydrocephalus. Ventriculoatrial and ventriculopleural shunting are alternative methods of CSF drainage, which have gained less acceptance. Ventriculopleural shunts are seldom used owing to justified fears of pneumothorax and symptomatic effusions of CSF. The addition of an antisiphon device to standard shunt systems seems to have prevented CSF pleural effusion. From 1988 to 1998, we treated each of six hydrocephalic children with a ventriculopleural shunt. In five cases we used new-technology valves designed to prevent the effects of siphoning with current differential pressure valves. Peritoneal adhesions, recent peritonitis, ascites, and obstruction of a previous ventriculoatrial shunt were the indications for pleural shunting. After a mean follow-up period of 2.5 years all shunts were functioning adequately. Only one patient showed transient symptoms of CSF overdrainage, which were corrected by up-grading the valve setting with the magnet. A late death was unrelated to the pleural shunting procedure. The use of valves of a new design designed to prevent overdrainage seems to account for the satisfactory outcomes observed in this series. We suggest that ventriculopleural shunting should be considered as the preferred alternative to peritoneal drainage in children with intra-abdominal adhesions or with a history of recent peritoneal infection.

  16. Suspension suture techniques in nasal valve surgery

    NARCIS (Netherlands)

    Page, Meile S.; Menger, Dirk J.

    2011-01-01

    Impaired nasal breathing or collapse of the lateral side wall of the nasal valve region during inspiration is a frequently encountered symptom. In general, this is caused by a cross-sectional area that is too small, a weak lateral side wall, or a combination of both. Over the years, many techniques

  17. Differential Pressure Helps Seal Ball Valve

    Science.gov (United States)

    Mangialardi, J. K.

    1985-01-01

    Leakage suppressed despite O-ring wear. New design eliminates leakage in vacuum selector valve on Space Shuttle waste-control subsystem. Applied to improve sealing in laboratory and industrial vacuum systems and other plumbing involving switching among lines with pressure differentials of order of 1 atmosphere (0.1 MPa).

  18. Autopsy after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    van Kesteren, F; Wiegerinck, E M A; Rizzo, S

    2017-01-01

    Autopsy after transcatheter aortic valve implantation (TAVI) is a new field of interest in cardiovascular pathology. To identify the cause of death, it is important to be familiar with specific findings related to the time interval between the procedure and death. We aimed to provide an overview ...

  19. Potentially fatal tricuspid valve aspergilloma detected after ...

    African Journals Online (AJOL)

    Potentially fatal tricuspid valve aspergilloma detected after laparoscopic abdominal surgery. ... Aspergillus endocarditis is usually associated with high morbidity and mortality. ... The patient was successfully managed with emergency open-heart surgery and systemic antifungal agents in the postoperative period. Keywords: ...

  20. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, Lau Caspar

    2015-01-01

    age (hazard ratio (95% CI): 1.3 (1.0-1.6)), male sex (1.2 (1.0-1.5)), mitral valve surgery (1.3 (1.0-1.6)), and infective endocarditis after surgery (1.8 (1.1-3.0), p: 0.01) predicted readmission, whereas higher age (2.3 (1.0-5.4)), higher comorbidity score (3.2 (1.8-6.0)), and infective endocarditis......BACKGROUND: After heart valve surgery, knowledge on long-term self-reported health status and readmission is lacking. Thus, the optimal strategy for out-patient management after surgery remains unclear. METHODS: Using a nationwide survey with linkage to Danish registers with one year follow-up, we...... included all adults 6-12 months after heart valve surgery irrespective of valve procedure, during Jan-June 2011 (n = 867). Participants completed a questionnaire regarding health-status (n = 742), and answers were compared with age- and sex-matched healthy controls. Readmission rates and mortality were...