  1. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  2. The causes and clinical significance of exercise-induced silent myocardial ischemia evaluated by ischemic range and intensity with exercise Tl-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Moriai, Naoki; Nakai, Kenji; Hiramori, Katsuhiko

    1992-01-01

    We investigated the causes and long-term prognosis of exercise-induced silent myocardial ischemia (SMI) by means of exercise Tl-201 myocardial SPECT (Ex-SPECT) in 97 patients with effort angina or old myocardial infarction (OMI). These patients were proven to have significant stenosis by coronary angiography. The subjects were divided into three groups based on the presence or absence of Tl-201 redistribution (RD) or angina during exercise testing. Group one consisted of 34 patients who had RD on Ex-SPECT and angina during exercise testing: the painful myocardial ischemia (PMI) group. The second group consisted of 38 patients who had RD on Ex-SPECT, but no angina during exercise testing: the SMI group. The third group consisted of 25 patients who had no RD: the RD (-) group. The ischemic range and intensity were quantified by the defect volume ratio (DVR) and defect severity index (DSI), respectively. Comparison of the DVR and DSI values for the PMI and SMI groups revealed that the DVR and DSI values for the SMI group were lower than those of the PMI group. Also the prognosis of the SMI group tended to be worse than that of the RD (-) group. Thus, we concluded that the SMI and PMI groups should receive identical treatment. (author)

  3. Cost-effectiveness of myocardial perfusion SPECT for diagnosis of coronary artery disease in Korea: comparison with exercise ECG and coronary angiography

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Kang, Keon Wook; Cheon, Gi Jeong; Jang, Myung Jin; Lee, Myoung Mook; Chung, June Key; Lee, Myung Chul

    2000-01-01

    Cost-effectiveness of myocardial SPECT for the diagnosis of coronary artery disease was investigated considering the present and amended costs of myocardial SPECT and exercise ECG in Korea. Four diagnostic tactics such as 1) coronary angiography (CAG) after exercise ECG, 2) CAG after myocardial SPECT, 3) direct CAG, and 4) CAG after myocardial SPECT following exercise ECG were chosen. Costs were calculated using the present costs of various tests and effects represented by Quality Adjusted Life Year (QALY) were estimated. Difference of QALY (ΔQALY) was calculated by subtracting QALY of diagnosed/treated cases from QALY of undiagnosed cases. Cost/ΔQALY was calculated and compared between four different tactics according to pre-test probability. When pre-test probability was equal to or larger than 0.6, direct CAG was the most cost-effective. When pre-test probability was between 0.2 and 0.6, CAG after myocardial SPECT following exercise ECG was the most cost-effective. CAG after myocardial SPECT was the second most cost-effective. Cost-effectiveness was similar when the costs of exercise ECG were doubled or quadrupled. CAG after exercise ECG was always the least cost-effective. Myocardial SPECT with or without preceding exercise ECG was the most cost-effective method to diagnose coronary artery disease in the present or expected amended cost system

  4. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  5. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  6. [Follow-up of patients with good exercise capacity in stress test with myocardial single-photon emission computed tomography (SPECT)].

    Science.gov (United States)

    González, Javiera; Prat, Hernán; Swett, Eduardo; Berrocal, Isabel; Fernández, René; Zhindon, Juan Pablo; Castro, Ariel; Massardo, Teresa

    2015-11-01

    The evaluation of coronary artery disease (CAD) can be performed with stress test and myocardial SPECT tomography. To assess the predictive value of myocardial SPECT using stress test for cardiovascular events in patients with good exercise capacity. We included 102 males aged 56 ± 10 years and 19 females aged 52 ± 10 years, all able to achieve 10 METs and ≥ 85% of the theoretical maximum heart rate and at least 8 min in their stress test with gated 99mTc-sestamibi SPECT. Eighty two percent of patients were followed clinically for 33 ± 17 months. Sixty seven percent of patients were studied for CAD screening and the rest for known disease assessment. Treadmill stress test was negative in 75.4%; 37% of patients with moderate to severe Duke Score presented ischemia. Normal myocardial perfusion SPECT was observed in 70.2%. Reversible defects appeared in 24.8% of cases, which were of moderate or severe degree (> 10% left ventricular extension) in 56.6%. Only seven cases had coronary events after the SPECT. Two major (myocardial infarction and emergency coronary revascularization) and 5 minor events (elective revascularization) ere observed in the follow-up. In a multivariate analysis, SPECT ischemia was the only statistically significant parameter that increased the probability of having a major or minor event. Nearly a quarter of our patients with good exercise capacity demonstrated reversible defects in their myocardial perfusion SPECT. In the intermediate-term follow-up, a low rate of cardiac events was observed, being the isotopic ischemia the only significant predictive parameter.

  7. Cost-effectiveness of exercise 201Tl myocardial SPECT in patients with chest pain assessed by decision-tree analysis

    International Nuclear Information System (INIS)

    Kosuda, Shigeru; Momiyama, Yukihiko; Ohsuzu, Fumitaka; Kusano, Shoichi; Ichihara, Kiyoshi

    1999-01-01

    To evaluate the potential cost-effectiveness of exercise 201 Tl myocardial SPECT in outpatients with angina-like chest pain, we developed a decision-tree model which comprises three 1000-patients groups, i.e., a coronary arteriography (CAG) group, a follow-up group, and a SPECT group, and total cost and cardiac events, including cardiac deaths, were calculated. Variables used for the decision-tree analysis were obtained from references and the data available at out hospital. The sensitivity and specificity of 201 Tl SPECT for diagnosing angina pectoris, and its prevalence were assumed to be 95%, 85%, and 33%, respectively. The mean costs were 84.9 x 10 4 yen/patient in the CAG group, 30.2 x 10 4 yen/patient in the follow-up group, and 71.0 x 10 4 yen/patient in the SPECT group. The numbers of cardiac events and cardiac deaths were 56 and 15, respectively in the CAG group, 264 and 81 in the follow-up group, and 65 and 17 in the SPECT group. SPECT increases cardiac events and cardiac deaths by 0.9% and 0.2%, but it reduces the number of CAG studies by 50.3%, and saves 13.8 x 10 4 yen/patient, as compared to the CAG group. In conclusion, the exercise 201 Tl myocardial SPECT strategy for patients with chest pain has the potential to reduce health care costs in Japan. (author)

  8. Comparison of diagnostic value of coronary artery disease between ATP-stress and exercise-stress thallium myocardial SPECT images

    International Nuclear Information System (INIS)

    Suzuki, Shigeo

    1994-01-01

    A study was made between adenosine triphosphate disodium (ATP)-stress thallium myocardial scintigrams and exercise-stress scintigrams to compare their respective extents and degree of defects. The subjects of the study were 33 ischemic heart disease patients, who received ATP stress and treadmill exercise stress with a mean interval of 25 days. ATP was infused for 5 minutes with an infusion rate of 0.16 or 0.18 mg per kg of body weight per minute. Thallium was injected three minutes after infusion. The percent-defect index (percentage of the extent and degree of the defects for all 33 patients), was calculated with visual scoring using a five-zone myocardial division method and semi-quantitative four-grade representation method for both the ATP and exercise SPECT images. The extent of the defects in ATP- and exercise-stress images was 51.5% and 44.2%, and that in redistribution images was 36.4% and 33.9%, respectively. The degree of defects in ATP- and exercise-stress images was 35.8% and 32.3%, while that in redistribution images was 20.8% and 17.2%, respectively (p=NS in all cases). In conclusion, the image quality of thallium SPECT with ATP stress was equivalent that of exercise stress, indicating identical diagnostic values for coronary lesions. (author)

  9. Quantification of 99mTc-MIBI lung uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Qu Wanying; Lu Zhenping; Zhou Ying; He Qin

    1996-01-01

    To assess the significance of 99m Tc-MIBI lung uptake during myocardial SPECT studies in the evaluation of left ventricular dysfunction. 42 control subjects and 65 patients with coronary artery disease (CAD) were investigated with 99m Tc-MIBI myocardial SPECT and radionuclide ventriculography (RNV) within 1 week. The lung-to-heart ratios (LHR) both at rest and exercise were calculated from the anterior projection of the SPECT image sets. The left ventricular ejection fraction (LVEF) was determined using RNV. In the control group, a significant decrease in LHR was observed during exercise (P<0.01). The CAD group showed significantly high LHR values both at rest and exercise. A negative correlation was observed between LHR values and LVEF at rest (r -0.6234, P<0.001) and exercise (r = -0.6113, P<0.001). LHR both at rest and exercise are significantly correlated with LVEF and may be useful in the evaluation of left ventricular function

  10. Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947 and Universite de Lorraine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Yagdigul, Yalcine; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947 and Universite de Lorraine, Nancy (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 and Denis Diderot University, Paris (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Poussier, Sylvain [INSERM U947 and Universite de Lorraine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep experimental imaging platform, Nancy (France); INSERM U1116 and Universite de Lorraine, Nancy (France); CHU-Nancy, Allee du Morvan, Medecine Nucleaire, Hopital de Brabois, Vandoeuvre-les-Nancy (France)

    2014-03-15

    Injected doses are difficult to optimize for exercise SPECT since they depend on the myocardial fraction of injected activity (MFI) that is detected by the camera. The aim of this study was to analyse the factors affecting MFI determined using a cardiac CZT camera as compared with those determined using conventional Anger cameras. Factors affecting MFI were determined and compared in patients who had consecutive exercise SPECT acquisitions with {sup 201}Tl (84 patients) or {sup 99m}Tc-sestamibi (87 patients) with an Anger or a CZT camera. A predictive model was validated in a group of patients routinely referred for {sup 201}Tl (78 patients) or {sup 99m}Tc-sestamibi (80 patients) exercise CZT SPECT. The predictive model involved: (1) camera type, adjusted mean MFI being ninefold higher for CZT than for Anger SPECT, (2) tracer type, adjusted mean MFI being twofold higher for {sup 201}Tl than for {sup 99m}Tc-sestamibi, and (3) logarithm of body weight. The CZT SPECT model led to a +1 ± 26 % error in the prediction of the actual MFI from the validation group. The mean MFI values estimated for CZT SPECT were more than twofold higher in patients with a body weight of 60 kg than in patients with a body weight of 120 kg (15.9 and 6.8 ppm for {sup 99m}Tc-sestamibi and 30.5 and 13.1ppm for {sup 201}Tl, respectively), and for a 14-min acquisition of up to one million myocardial counts, the corresponding injected activities were only 80 and 186 MBq for {sup 99m}Tc-sestamibi and 39 and 91 MBq for {sup 201}Tl, respectively. Myocardial activities acquired during exercise CZT SPECT are strongly influenced by body weight and tracer type, and are dramatically higher than those obtained using an Anger camera, allowing very low-dose protocols to be planned, especially for {sup 99m}Tc-sestamibi and in non-obese subjects. (orig.)

  11. Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera

    International Nuclear Information System (INIS)

    Verger, Antoine; Karcher, Gilles; Imbert, Laetitia; Yagdigul, Yalcine; Roch, Veronique; Fay, Renaud; Djaballah, Wassila; Rouzet, Francois; Le Guludec, Dominique; Fourquet, Nicolas; Poussier, Sylvain; Marie, Pierre-Yves

    2014-01-01

    Injected doses are difficult to optimize for exercise SPECT since they depend on the myocardial fraction of injected activity (MFI) that is detected by the camera. The aim of this study was to analyse the factors affecting MFI determined using a cardiac CZT camera as compared with those determined using conventional Anger cameras. Factors affecting MFI were determined and compared in patients who had consecutive exercise SPECT acquisitions with 201 Tl (84 patients) or 99m Tc-sestamibi (87 patients) with an Anger or a CZT camera. A predictive model was validated in a group of patients routinely referred for 201 Tl (78 patients) or 99m Tc-sestamibi (80 patients) exercise CZT SPECT. The predictive model involved: (1) camera type, adjusted mean MFI being ninefold higher for CZT than for Anger SPECT, (2) tracer type, adjusted mean MFI being twofold higher for 201 Tl than for 99m Tc-sestamibi, and (3) logarithm of body weight. The CZT SPECT model led to a +1 ± 26 % error in the prediction of the actual MFI from the validation group. The mean MFI values estimated for CZT SPECT were more than twofold higher in patients with a body weight of 60 kg than in patients with a body weight of 120 kg (15.9 and 6.8 ppm for 99m Tc-sestamibi and 30.5 and 13.1ppm for 201 Tl, respectively), and for a 14-min acquisition of up to one million myocardial counts, the corresponding injected activities were only 80 and 186 MBq for 99m Tc-sestamibi and 39 and 91 MBq for 201 Tl, respectively. Myocardial activities acquired during exercise CZT SPECT are strongly influenced by body weight and tracer type, and are dramatically higher than those obtained using an Anger camera, allowing very low-dose protocols to be planned, especially for 99m Tc-sestamibi and in non-obese subjects. (orig.)

  12. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  13. 201Tl myocardial SPECT and β-endorphin levels in patients with suspected silent ischemia

    International Nuclear Information System (INIS)

    Lind, P.; Binter, G.; Koeltringer, P.; Eber, O.; Eber, B.; Klein, W.; Brandt, D.

    1990-01-01

    Today silent myocardial ischemia (SMI) is a well-recognized phenomenon. Treadmill exercise according to the Bruce protocol, 201 Tl myocardial SPECT and coronary angiography were performed in a total of 106 patients with suspected SMI. In group I (high probability of ischemia; n=46), reversible defects detected by SPECT correlated well with significant stenoses and irreversible defects with subtotal stenoses or complete occlusions. SPECT sensitivity in the detection of ischemia was 91%, its specificity 96%. In group II (low probability of ischemia; n=60), SPECT sensitivity was as high as in group I (94%) but due to a high number of false-positive results (e.g. cardiomyopathy) specificity was only 75%. However, SPECT was superior to exercise ECG (sensitivity 70%; specificity 56%) in the detection of SMI. In addition, β-endorphin levels were determined in 180 healthy subjects, 37 patients with symptomatic CAD and in 34 patients with SMI before and during maximum exercise. Exercise values in patients with SMI were significantly higher than in healthy subjects or in patients with symptomatic CAD. (orig./MG) [de

  14. Evaluation of exercise-induced myocardial stunning by means of immediate post-exercise Tc-99m sestamibi gated SPECT

    International Nuclear Information System (INIS)

    Ouvrier, M.J.; Hitzel, A.; Vera, P.; Manrique, A.; Bernard, M.; Manrique, A.

    2009-01-01

    Aim: Repeated episodes of myocardial stunning may lead to chronic ventricular dysfunction. We attempted to assess the parameters related to post-exercise stunning in patients undergoing gated SPECT. Methods: Six hundred patients undergoing a one-day stress/rest 99m Tc-sestamibi gated SPECT were studied. Stress imaging was acquired within 15 minutes after injection. Summed perfusion scores (S.S.S., S.R.S. and S.D.S.) were calculated using Q.P.S., and L.V. function assessed using Q.G.S.. Stunning was defined as the association of ischemia (S.S.S. = 4 and SDS > 0) and a minimum of 5% decrease in post-stress E.F.. Results: Ischemia was found in 225 (37.5%) patients. Among these, 67 (30%) showed myocardial stunning. Patients with stunning had a lower rest E.S.V. (47 ± 24 ml vs 65 ± 52 ml, p < 0.0003) and E.D.V. (108± 35 ml vs 122 ± 66 ml, p 0.03), an increased rest L.V.E.F. (58 ± 10% vs 52 ± 13%, p < 0.0001) and a decreased post-stress L.V.E.F. (49 ± 10% vs 53 ± 13%, p < 0.02) compared to patients with no stunning. The number of myocardial segments showing reversible perfusion defects was increased in patients with stunning (2.7 ± 2.6 vs 1.7 ± 2.1, p < 0.02). On logistic regression, an extent of ischemia greater than two segments and a rest E.F. greater than 45% were independent predictors of the occurrence of myocardial stunning in patients with ischemia. Conclusions: In patients with ischemia, exercise-induced stunning was associated with an increased extent of ischemia but also preserved rest ventricular function. (authors)

  15. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi

    2000-01-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V 2 , V 3 and V 4 leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV F , V 5 and V 6 leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  16. Myocardial SPECT in children with sickle cell disease

    International Nuclear Information System (INIS)

    Maunoury, C.; Hallaj, I.; Barritault, L.; Acar, P.; Montalembert, M. de

    2002-01-01

    Aim: While cerebral and bones strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Conventional techniques such as exercise testing and echocardiography have a low sensitivity and specificity to detect myocardial ischemia in patients with SCD. The aim of this prospective study was to assess myocardial perfusion with 201 Tl SPECT in children with SCD. Materials and Methods: Twenty-two patients, aged 12 ± 4 years, were included. Myocardial perfusion was assessed by 201 Tl SPECT after stress and 3 hours later after reinjection on a single head gammacamera equipped with a LEAP collimator (64x64 matrix size format, 30 projections over 180 0 , 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Results: Myocardial perfusion was impaired in 13/22 patients: 8 had reversible defects and 5 had fixed defects. The left ventricular cavity was dilated in 13/22 patients. The mean LVEF was 63 ± 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. Conclusion: Myocardial perfusion is frequently impaired in children with SCD. Treatment with hydroxyurea should be considered in SCD patients with perfusion defects

  17. The clinical application of SPECT myocardial perfusion imaging with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Dong Weiyu

    1992-01-01

    This paper reported 182 SPECT myocardial perfusion images with China made 99m Tc-MIBI and were compared with ECG and UCG. The sensitivity of SPECT in ischemic were 91.2% and was higher than ECG (74.9%)and UCG (61.8%) (P < 0.01). And its specificity, accuracy and positive predictive rate were 78.3%, 90% and 97% respectively. Besides 9 cases have reverse distribution after exercise and rest images. In some ICD patients had shown their SPECT images, the perfusion defects in exercise as well as in rest image

  18. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  19. Detecting culprit vessel of coronary artery disease with SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Zhou Wen; Peng Yong; Su Yuwen; Tian Jianhe; Gai lue; Sun Zhijun

    2002-01-01

    Objective: To assess the value of detecting culprit vessel of coronary artery disease (CAD) with SPECT 99 Tc m -MIBI myocardial imaging. Methods: Forty-six patients with CAD were studied. Every patients had multiple-vessel lesion showed by coronary arteriography and was treated by revascularization as percutaneous transluminal angioplasty (PTCA), coronary artery bypass graft (CABG) or laser holing. Exercise (EX), rest (RE) and intravenous infusion of nitroglycerine (NTG) SPECT 99 Tc m -MIBI myocardial imagings were performed before revascularization. Exercise and rest images revealed the myocardial ischemia. NTG images revealed myocardial viability. Culprit vessels were detected according to the defects showed by above mentioned images. The veracity of detected culprit vessels was tested with the outcome of the reperfusion therapy. Results: In this group, the coronary arteriography revealed 107 lesioned coronary arteries. Myocardial imaging detected 46 culprit vessels including 23 left anterior descending (LAD), 19 left circumflex coronary artery (LCX) and 4 right coronary artery (RCA). All 46 culprit vessels underwent revascularization and had nice outcome. The veracity of 99 Tc m -MIBI myocardial imaging detected culprit vessels was high according to patients' outcome. Conclusion: Exercise, rest and NTG 99 Tc m -MIBI myocardial imaging is a great method for detecting culprit vessels in multivessel coronary disease

  20. Usefulness of rest-redistribution on thallium myocardial scintigraphy in patients with acute myocardial infarction by SPECT; Analysis by bull's eye and unfolded map images

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yorio; Taya, Makoto; Sasaki, Akira; Nishimura, Tooru; Shimoyama, Katsuya; Mizuno, Haruyoshi; Ono, Akifumi; Okada, Michio; Ishikawa, Kyozo (Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine)

    1990-01-01

    The purpose of this study was to clarify the clinical significance of rest-redistribution in myocardial scintigraphy (SPECT) in acute myocardial infarction (AMI). 30 patients with AMI within one week after the onset of attack were studied. SPECT images were obtained 10 min and 3hrs after injection of {sup 201}Tl. Bull's eye images and unfolded map images were prepared. A {sup 201}Tl uptake was studied at the infarct and non-infarct sites. Exercise SPECT and radionuclide angiography were performed in all patients one month after the onset of AMI, and the findings were compared with clinical and coronary angiographic (CAG) findings. Redistribution of Tl at rest was observed at the infarct sites in 9 of the 30 patients. Redistribution at rest was observed at the non-infarct sites in 8 patients. Redistribution at rest was observed during exercise SPECT one month after the onset of AMI in patients with redistribution at rest in the acute phase. In patients with redistribution at rest at the infarct site, left ventricular ejection fraction (EF) improved one month after the onset of AMI ({Delta}EF>5%), but it decreased slightly during exercise. Wall motion at the infarct site was not much impaired in patients who showed redistribution at rest at the infarct site. Angina pectoris and recurrence of myocardial infarction were observed more frequently on SPECT, but no characteristic findings were obtained on CAG in those with redistribution at rest. In conclusion, cardiac function and wall motion at the infarct site are better preserved in patients with redistribution of Tl at rest on SPECT in the acute stage of myocardial infarction, as compared with patients having fixed defects, but the EF decrease slightly during exercise and the frequency of post-infarction angina is greater in those patients. Resting SPECT in AMI is considered to provide useful information for predicting cardiac function and the clinical course following myocardial infarction. (author).

  1. Exercise and rest Tl-201 myocardial SPECT, and low dose dobutamine echocardiography to assess myocardial viability in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Toyama, Takuji; Ishida, Yoshio; Shimonagata, Tsuyoshi; Kawano, Shigeo; Beppu, Shintaro; Nishimura, Tsunehiko.

    1994-01-01

    To evaluate viability of infarcted myocardium, findings of Tl-201 myocardial SPECT were compared with those of low-dose dobutamine (DOB) echocardiography. The subjects were 19 patients with myocardial infarction (23 infarcted zones), consisting of 16 men and 3 women. Findings on myocardial SPECT were classified as evidence of myocardial viability (14 zones, Group A) and no evidence of myocardial viability (9 zones, Group B). For both groups, wall motion and regional % uptake (%UP) were obtained. DOB echocardiography revealed an improvement in 5 of 8 akinesis zones in Group A. In addition, one other zone was found improved by follow-up examination. Six hypokinesis zones were all found improved on DOB echocardiography. Out of a total of 14 akinesis or hypokinesis zones, 11 (79%) showed improvement on DOB echocardiography in Group A. In Group B, all akinesis zones remained unchanged on DOB echocardiography, although one zone was improved by follow-up examination. In 11 zones in which wall motion was improved on DOB echocardiography, %UT was increased by an average of 58% on 4 hr-delayed images and 70% on resting images. The corresponding figures for 12 zones which did not improve on DOB echocardiography were 49% and 50% on the average, respectively. In conclusion, low-dose DOB echocardiography appeared to reflect viability of severely infarcted myocardium, although it had a slightly lower sensitivity than convensional Tl-201 myocardial SPECT in its ability to detect. (N.K.)

  2. Cold pressor test myocardial perfusion SPECT as a predictor of the development of ischemia at exercise in the follow up of asymptomatic patients with moderate cardiovascular risk

    International Nuclear Information System (INIS)

    Traverso, Sonia S.; Redruello, Marcela F.; Grynberg, Laura E.; Cragnolino, Daniel E.; Maciel, Neiva R.; Masoli, Osvaldo H.; Perez Balino, Nestor A.; Meretta, Alejandro

    2007-01-01

    Introduction: Previous studies have published the correlation between myocardial perfusion SPECT (MP) during cold pressor test (CPT) and intracoronary acetylcholine and its usefulness as independent marker of endothelial dysfunction (ED). Objective: To analyze the incidence of positivization of MP exercise studies in the follow up of asymptomatic patients with moderate cardiovascular risk (CV) and ED detected by PF. Material and Methods: Of 301 patients of the PARADIGMA Registry (normal exercise MP SPECT and clinical probability [es

  3. Value of dipyridamole stress 201Tl myocardial SPECT in detecting dysfunction of coronary microcirculation

    International Nuclear Information System (INIS)

    Lou Ying; Jiang Jinqi; Xie Wenhui; Yuan Fang; Wang Tong; Yang Yiqing

    2012-01-01

    Objective: To evaluate the value of dipyridamole stress 201 Tl myocardial SPECT in detecting dysfunction of coronary microcirculation. Methods: Forty-eight patients diagnosed with cardiac syndrome X underwent dipyridamole stress 201 Tl myocardial SPECT. Dipyridamole (0.56 mg/kg) was intravenously injected over 4 min followed by 201 Tl (111 MBq) injection at 2 min after dipyridamole administration. Image was acquired at 10 min and 240 min post-injection and co-analyzed by over two experienced doctors in nuclear medicine after three-dimensional reconstruction. The patients with 'reverse redistribution' underwent repeated dipyridamole stress 201 Tl SPECT after medical therapy for 2 weeks. The clinical symptoms and results of the treadmill exercise test pre-and post-therapy were compared. Results: Forty two patients (42/48, 87.50%) showed segmental defects: 'reverse redistribution' on delayed (240 min) 201 Tl images. After medical treatment, 36 cases of the 42 'reverse redistribution' patients had improvement in both clinical symptoms and treadmill exercise test. Post-treatment 201 Tl imaging showed improvement in 45/49 (91.84%) defect segments. Six of the 42 patients had no improvement in clinical symptoms and/or treadmill exercise test. Post-treatment 201 Tl imaging showed no improvement in all the 7 defect segments on the first scan. Conclusion: Dipyridamole stress 201 Tl myocardial SPECT may be valuable in evaluation of impaired coronary microcirculation associated with cardiac syndrome X. (authors)

  4. Quantification of reversible perfusion abnormality using exercise-stress thallium SPECT before and after coronary revascularization

    International Nuclear Information System (INIS)

    Nagao, Kazuhiko; Nakata, Tomoaki; Tsuchihashi, Kazufumi

    1994-01-01

    Reversible myocardial perfusion abnormality was quantified by bull's eye and unfolded surface mapping methods in exercise thallium SPECT before and after coronary revascularization in 47 patients with angina pectoris, including 34 patients with previous myocardial infarction (PMI) and 13 with effort angina (AP). There was no difference in the incidence or extent of myocardial ischemia between the 2 groups before revascularization. However, the ischemic scores were significantly smaller in PMI group preoperatively than the reductions of the ischemic scores after revascularization. The ischemic scores, preoperatively estimated reversible perfusion abnormality was 32%, 69% and 48% of the improvement of the ischemic score (extent score, severity score, and ischemic area, respectively). Using the 3 ischemic scores, the improvement of perfusion abnormality was well predicted in 70-89% of AP patients but 35-57% of PMI patients. Thus, quantitative analysis in stress thallium SPECT is useful for detecting myocardial ischemia and evaluating the effect of coronary revascularization. However, about a half of myocardial viability was underestimated in one third of PMI patients by the conventional exercise-stress thallium SPECT study. (author)

  5. Semiquantitative SPECT myocardial perfusion with dipyridamole in patients unable to exercise. Event rate during 4 years of follow up

    International Nuclear Information System (INIS)

    Balestrini, V.R.; Arja, V.J.; Sandrin, A.L.; Calvo, G.R.; Gomez Bosh, Z.; Quiroga, W.; Balestrini, C.E.; Joekes, S.

    2002-01-01

    The increasingly numbers of patients (P) that can't reach an adequate level of exercise in order to evaluate CAD, lead us to use pharmacological and technical tools available for this subgroup of P. Aim: evaluate the prognostic significance of myocardial perfusion SPECT imaging with pharmacological stress in P without LBBB, unable to exercise. Material and Methods: 209 P were included. Mean age: 65 years old (39-88), male 66%. Clinical: Pre test likelihood 8: 28%; SDS 0 and SRS 0: 31.7%; SDS 0 + SRS >=1: 21%; SDS >=1: 47.3%. III) Follow up: 13 patients were early re-vascularized induced by SPECT study results, 10 patients get lost and 186 were follow up by a mean 1086 days. Cumulative events rate: 1st year SCE 9.7%, HCE 1.6%; 2nd year SCE 14%, HCE 4.3%; 3rd year SCE 17.7%, HCE 5.4%; 4th year SCE 21%, HCE 5,4%. Scintigraphic indices and events rate relationship are presented. Conclusion: There was a relationship between scintigraphic indices and hard cardiac events. The semiquantitative myocardial perfusion with dipyridamole stress was a safe test and useful to discriminate groups of P with different risk of events

  6. Transient ischemic dilation ratio (TID) correlates with HbA1c in patients with diabetes type 2 with proven myocardial ischemia according to exercise myocardial SPECT

    International Nuclear Information System (INIS)

    Adamikova, A.; Rybka, J.; Bakala, J.; Bernatek, J.; Svacina, S.

    2006-01-01

    Abnormal values of the transient ischemic dilation ratio (TID) according to an exercise myocardial single photon emission computed tomography (SPECT) are linked to severe coronary artery disease. The authors investigated the relationship between TID and the levels of vascular cell adhesion molecule (VCAM), intercellular adhesion molecule (ICAM), E-selectin, microalbuminuria, intimamedia thickness and HbA 1c of diabetic subjects. We observed 38 subjects with diabetes type 2 (10 women, 28 men), of average age 56.08±8.24 years, with no past history of cardiovascular disease. All subjects were examined using an exercise myocardial SPECT. Transient ischemic dilation, summed stress score (SSS), summed rest score (SRS) and stress total severity score (STSS) were determined to quantify myocardial ischemia. The average IMT value was 1.05±0.31 mm. The TID value was 1.02±0.154, VCAM 795.24±163.25 mg/l, ICAM 516.55±164.07, E-selectin 63.82±38.89, HbA 1c 7.09±1.68%, microalbuminuria 68.01±55.21 mg/l. When ascertaining the relation of TID to the other factors we used Pearson's correlation at the level of significance p 1c (p=0.035); the other factors did not show any significant correlation. Diabetes and its long term unsatisfactory compensation can be one of the factors which affect left ventricular transient ischemic dilation. (author)

  7. Value of myocardial perfusion SPECT in pediatric population

    International Nuclear Information System (INIS)

    Massardo, T.; Coll, C.; Prat, H.; Gonzalez, P.; Doggenweiller, P.; Castillo, M.E.; Solis, A.

    2002-01-01

    Isotopic myocardial perfusion studies are less frequently used in children than in adults and their indications are also different. Our goal was to analyze retrospectively the experience with stress perfusion myocardial SPECT in pediatric population. Method: Since 1998 to 2001, ten studies were performed to 5 girls and 3 boys. Their mean age was 7±3 years ranging from 1-11. Three of them presented abnormal coronary arteries pre and post surgical intervention with or without coil; three had Kawasaki disease with coronary aneurysms and the other two, congenital cardiopathies (Cantrell pentalogy and great vessel transposition,both with posterior left ventricular hypokinesia post surgery). Stress was obtained using dipyridamole infusion (0.56 mg/kg) in 6 cases and treadmill exercise using Bruce protocol in 4. All those tests were well tolerated. Sestamibi Tc99m was selected in 80% of the cases and Tl 201 in the rest. Only 2 small children required anesthesia during SPECT acquisition. Results: Stress EKG did not demonstrated ischemia in any case. Coronary angiography was performed only in 50% of the patients, it was concordant with SPECT features in all, two of those patients presented transient perfusion defects (one Kawasaki and one abnormal coronary artery with a fistulae).The repaired pentalogy presented ischemia and septal infarction; in that patient echocardiographic hipokinesia was concordant with fixed hypoperfusion. One case with abnormal coronary plus mitral regurgitation (without isotopic ischemia) was submitted to embolization posteriorly, obtaining motion improvement. Clinical outcome was concordant with the presence or absence of isotopic ischemia in the rest of the patients. Conclusion: SPECT myocardial perfusion was helpful in the therapeutic approach and in prediction of outcome in children

  8. Supervising PTCA treatment with a scheme of steps combination SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Tian Jiahe; Peng Yong; Zhou Wen; Gai Luyue; Sun Zhijun; Su Yuwen; Liu Xiaohu

    2001-01-01

    Objective: To set up a useful supervising method around PTCA treatment. Methods: A scheme of steps combination SPECT 99 Tc m -MIBI myocardial imaging was devised. 87 patients with coronary artery disease were selected into the study. 3-step imaging, exercise, rest and intravenous infusion of nitroglycerine (NTG) imaging, was performed at 1 week before PTCA. 2-step imaging, exercise and rest imaging, was performed 1-2 weeks after PTCA. All of the indexes obtained from steps combination imaging before and after PTCA were contrasted with each other in pairs. Results: 1) Compared with outcome of clinical assessing, the imaging after PTCA could correctly assess PTCA outcome. 2) The myocardial defects showed in 3-step imaging before PTCA appeared to be ameliorated after PTCA and the amelioration showed in exercise imaging was more evident than that in rest imaging. The myocardial perfusion state revealed by NTG imaging was similar to that revealed by rest imaging after PTCA. 3) The 3-step imaging findings correlated with PTCA outcome, the best correlation was found between indexes of myocardial defect changes showed by NTG and exercise imaging and indexes of PTCA outcome (r = 0.9470, P 99 Tc m -MIBI myocardial SPECT imaging scheme is a very useful supervising method around PTCA. 2-step imaging after PTCA could assess outcome correctly, and 3-step imaging before it could predict outcome correctly, too

  9. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  10. Diagnostic ability of Tc-99m MIBI SPECT in coronary artery diseases in not affected by the degree of exercise

    International Nuclear Information System (INIS)

    Lee, Jae Tae; Kim, Jong Soo; Chun, Kyung Ah; Lee, Sang Woo; Kang, Do Young; Cho, Yong Keun; Chae, Shung Chull; Lee, Kyu Bo

    1999-01-01

    The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression of exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmil exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease

  11. Diagnostic value of myocardial tomographic imaging with 123I labelled BMIPP for exercise-induced angina pectoris

    International Nuclear Information System (INIS)

    Wang Lijuan; Kaname Akioka; Hiroyuki Yamagishi

    1999-01-01

    Objective: To evaluate the diagnostic value of resting myocardial tomographic imaging with 123 I labelled BMIPP ( 123 I-BMIPP SPECT) for exercise-induced angina pectoris by comparison with stress myocardial tomographic imaging with 201 Tl( 201 Tl SPECT). Methods: 123 I-BMIPP SPECT and 201 Tl SPECT were performed in 32 patients with exercise-induced angina pectoris and 12 normal controls. Left ventricle was divided into nine segments and uptake of 201 TL and 123 I-BMIPP was evaluated by four classes score method (defect score, DS). Results: In the patients with angina pectoris, segments of 201 Tl distribution abnormality were more than that of 123 I-BMIPP. Concordant rate between DS of the 20 '1Tl SPECT for detecting coronary artery stenosis were 62%, 92% and 70%, respectively, and 201 Tl SPECT were 84%, 83% and 84%, respectively. Sensitivity of 123 I-BMIPP SPECT was significantly lower than that of 201 Tl SPECT (P 123 I-BMIPP SPECT will be. Conclusions: The results indicated that to a certain extent, resting 123 I-BMIPP SPECT may has practical clinical value for detection of coronary artery stenosis, and determination of stenotic degree in the patients with exercise-induced angina pectoris

  12. Tl myocardial SPECT demonstrates importance of collateral circulation in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Hattori, Fukunori

    1997-01-01

    The influence of collateral circulation on the preservation of myocardial viability and the efficacy of drug therapy and PTCA were evaluated by exercise 201 Tl myocardial SPECT before and after treatment. Thirty-five patients with a history of myocardial infarction resulting from total or subtotal obstruction of the responsible coronary artery were divided into four groups, according to the method of the treatment and the degree of collateral blood flow. Patients in groups A and B received drug therapy and displayed developed and undeveloped collateral circulation, respectively. Groups C and D received PTCA and displayed developed and undeveloped collateral circulation, respectively. Tl myocardial SPECT was performed before treatment to record the extent of redistribution to the occluded region, the degree of myocardial viability and the nature and extent of the ischemic lesion. In group A, myocardial perfusion improved, although redistribution remained in all cases, while in group B, 4 of 7 cases improved after drug therapy. In group C, myocardial perfusion improved in all cases, and redistribution disappeared in 7 of 12 cases. 5 of 6 cases improved in group D after PTCA. After drug therapy, the %Tl uptake in the infarcted region improved significantly in initial and delayed images of patients in group A. The differences in initial and delayed images in group B before and after drug therapy were not significant. In contrast, groups C and D both registered significant improvement in initial and delayed images after PTCA. The washout rate improved significantly in groups A, C and D after their respective treatments. These results suggest that developed collateral circulation helps to preserve myocardial viability in cases of myocardial infarction. Myocardial perfusion improved after drug therapy in cases with developed collateral circulation, and in patients with developed and undeveloped collateral circulation receiving PTCA. (K.H.)

  13. Significance of 99mTc-MIBI myocardial SPECT imaging in diagnosis of syndrome X

    International Nuclear Information System (INIS)

    Tian Yueqing; Liu Xiujie; Jiao Shubin

    1996-01-01

    To assess the value of myocardial imaging in the diagnosis of syndrome X, the study was performed with 99m Tc-MIBI myocardial SPECT imaging in 64 patients. The patients were divided into three groups: group 1 had 21 patients diagnosed as syndrome X, group 2 had 17 patients with chest pain and normal coronary arteries without ST segment depression during exercise, group 3 had 26 patients with the angina pectoris and coronary stenoses≥50%. The myocardial SPECT imaging of the three groups was compared qualitatively and semi-quantitatively. Myocardial imaging identified 11 cases of myocardial ischemia from 21 patients with syndrome X. The ischemic score of myocardial imaging was 1.1 +- 0.3 for syndrome X and 1.8 +- 0.7 for patients with coronary heart disease (CHD) angina pectoris (t = 3.1746, P<0.01). Myocardial imaging may partly show myocardial ischemia in patients with syndrome X. The extent of ischemia in patients with syndrome X was significantly less than that in patients with CHD angina pectoris

  14. Usefulness of hyperventilation myocardial SPECT for diagnosing vasospastic angina pectoris

    International Nuclear Information System (INIS)

    Tahara, Yorio; Shimoyama, Katsuya; Nishimura, Tooru; Sasaki, Akira; Taya, Makoto; Mizuno, Haruyoshi; Ono, Akifumi; Tsuya, Tsuneo; Ishikawa, Kyozo

    1990-01-01

    We evaluated the usefulness of hyperventilation myocardial scintigraphy (HV-SPECT) for diagnosing vasospastic angina pectoris. The subjects consisted of 11 patients with rest angina and 13 with rest and exertional angina in whom coronary spasm was demonstrated by coronary angiography, and 6 with exertional angina in whom a significant stenotic lesion was observed by coronary angiography. Hyperventilation was performed at a rate of 40/min for 5 minutes in all the patients. Ischemia was considered to be present when defect and redistribution were observed by SPECT. HV-SPECT revealed positive findings in 8 patients with rest angina (73%) and 9 with exertional and rest angina (69%) but only in 1 with exertional angina (17%). Ischemic ST changes on monitor ECG were observed in 13 of the 30 patients (43%); ST was enhanced in 4 patients and depressed in 9 patients. In the patients with rest angina, HV-SPECT induced ischemic findings more frequently than exercise SPECT (73% vs 55%). HV-SPECT seems to be useful as a non-invasive method for diagnosing angina pectoris resulting from coronary spasm. (author)

  15. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  16. Rest delayed images on 99mTc-MIBI myocardial SPECT as a noninvasive screen for the diagnosis of vasospastic angina pectoris

    International Nuclear Information System (INIS)

    Ono, Soichi; Yamaguchi, Hiroyuki; Takayama, Shin; Kurabe, Atsushi; Heito, Takayuki

    2002-01-01

    Diagnostic usefulness of 99m Tc-hexakis-2-methoxy isobutyl isonitrile (MIBI) myocardial SPECT at rest was examined in 39 cases of coronary vasospastic angina pectoris who were diagnosed by a positive reaction to ergonovine provocation. SPECT was performed 45 minutes (early image) and 3 hours (delayed image) after the intravenous injection of approximately 600 MBq of MIBI. Decrease in accumulation was ranked by four defect scores (0: normal; 1: slight decrease; 2: moderate decrease; 3: severe decrease) and the total defect score was evaluated semiquantitatively. The washout rate between the normal area and the spasm area was also evaluated quantitatively using bull's eye. As a result, 15 cases (15/39; 38.4%) showed decreased accumulation in the early image and 27 cases (27/39; 69.2%) showed decreased accumulation in the delayed image. All of the cases which showed decreased accumulation in the early image had decreased accumulation in the delayed image as well. In 6 cases (6/34; 17.6%) showed ST wave changes during exercise ECG and 16 cases (16/34: 47%) showed decreased accumulation in the exercise myocardial SPECT. The washout rate of MIBI in the decreased accumulation area was significantly higher than that of the normal area. Of 32 ergonovine induced vasospastic area, 23 areas (72%) exhibited decreased accumulation in the delayed image for the same area. Decreased accumulation in the delayed image in MIBI was due to the enhanced washout, which, in turn, indicated declined retention of MIBI by mitochondrial membrane. In coronary vasospastic angina pectoris, spasm induced ischemia was thought to have an effect on the mitochondria. This study suggested that even with a normal exercise ECG and exercise myocardial SPECT, there's a strong possibility of coronary vasospastic angina pectoris if a decreased accumulation was found in the delayed image in the MIBI myocardial SPECT at rest. Hence, in diagnosing coronary vasospastic angina pectoris, the delayed image in the

  17. Usefulness of isoproterenol stress thallium-201 myocardial single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi

    1990-01-01

    Twenty patients complaining of chest pain were referred for isoproterenol stress thallium-201 myocardial single photon emission computed tomography (ISO-SPECT). The findings were compared with those obtained from isoproterenol stress ECG testing (ISO-ECG) and exercise SPECT (EX-SPECT). Isoproterenol was iv injected in a dose of 0.02 μg/kg/min. The amount was continuously increased until limited by chest pain, ST depression, and/or determined heart rate criteria. The patients were scanned immediately and three hours after giving isoproterenol. Transient hypoperfusion was regarded as myocardial ischemia. Washout rate, obtained from circumferential profile analysis on the short axis SPECT images, was expressed by Bull's eye display. Fifteen patients with angiographically significant stenosis of 75% or greater were diagnosed as having coronary artery disease (CAD). The other five patients had normal coronary artery (NC). In diagnosing CAD, ISO-ECG and ISO-SPECT had a sensitivity of 80% and 92%, respectively. Because the NC group had negative findings for redistribution on ISO-SPECT, the specificy of ISO-SPECT seemed to be high. For multi-vessel disease, redistribution on ISO-SPECT tended to underestimate coronary lesions. The underestimation was, however, corrected by calculating washout rate. For evaluable 11 patients undergoing concurrent EX-SPECT, ISP-SPECT was equivalent or superior to EX-SPECT in diagnostic sensitivity. None of the patients had severe side effects of isoproterenol, except for some having arrhythmia. The results indicated that ISO-SPECT is a safe, high sensitive diagnostic approach that is comparable to Ex-SPECT. (N.K.)

  18. Relationship between normalization of negative T waves on exercise ECG and residual myocardial viability in patients with previous myocardial infarction and no post-infarction angina

    Energy Technology Data Exchange (ETDEWEB)

    Ajisaka, Ryuichi; Watanabe, Shigeyuki; Masuoka, Takeshi; Yamanouchi, Takayoshi; Saitoh, Takumi; Toyama, Masahiro; Takeda, Tohru; Itai, Yuji; Sugishita, Yasuro [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    1998-03-01

    The usefulness of normalization of negative T waves in exercise ECG was investigated as an index of myocardial viability in patients with previous myocardial infarction with no symptoms or ischemic ST-segment change during exercise test. A total of 39 patients, 20 with T-wave normalization (POS group) and 19 without T-wave normalization (NEG group) on exercise ECG, were studied. Myocardial viability was evaluated by thallium-201 single-photon emission computed tomography (SPECT) during exercise or at rest. We also assessed left ventricular ejection fraction (LVEF) by contrast ventriculography before (n=39) and after percutaneous transluminal coronary angioplasty (PTCA) (n=17). SPECT detected myocardial viability in 16 (80%) of the 20 patients in the POS group and in 4 (21%) of the 19 patients in the NEG group (p<0.01). LVEF increased after successful PTCA in the POS group (from 53{+-}13% to 63{+-}8%, p<0.025), but fell in the NEG group (from 57{+-}10% to 51{+-}8%). It is concluded that normalization of negative T waves on exercise ECG is a useful, simple index of myocardial viability in patients with previous myocardial infarction with no symptoms or ischemic ST-segment change during exercise testing. (author)

  19. Prognosis of patients with positive exercise test and normal myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Ahn, B. C.; Lee, J.; Lee, K. B [College of Medicine, Kyungpook National University, Daegu (Korea, Republic of)

    2004-07-01

    Exercise SPECT myocardial perfusion imaging(Ex-MPI) is regarded as a predictive technique particularly in patients with coronary artery disease(CAD) capable of performing exercise testing. In clinical practice, we encounter equivocal situations of discordant findings between exercise ECG and MPI. We evaluated the prognosis of subjects with positive ECG and normal MPI findings, and predictive factors for cardiac events. 2571 Ex-MPI studies were reviewed over a period of 3 years. Subjects were followed for more than 2 years(24-56 months, mean 35{+-}10months) for cardiac events after study. The cardiac events were defined as hard events(cardiac death and nonfatal myocardial infarction(MI)) and soft events(aggravation of CAD necessitating revascularization, congestive heart failure necessitating hospital admission). We evaluated age, sex, typical angina pain, rest ECG, hypertension, diabetes mellitus(DM), serum levels of cholesterol and LDL, smoking history, history of cerebrovascular disease(CVD) and peripheral artery disease(PAD), and rest left ventricular ejection fraction(LVEF) as clinical variables. Of 83 subjects with positive ECG and normal MPS findings, 6 were considered as false negative results confirmed with coronary angiography. There were 77 patients (mean age 52{+-}10 years, 39 males) with positive ECG and normal MPI results. During the follow-up period, of 77 there were 3 cardiac events (annual rate 1.9%), no cardiac death, 2 nonfatal MIs (annual rate 1.3%) and 1 soft event (annual rate 0.6%). 2/39 males(5.1%), and 1/38 females(2.6%) had cardiac events. All cardiac events were observed within 2 years. 1-year cardiac event rate was 0.6% and 2-year cardiac event rate was 1.9%. Among clinical factors, male sex, typical chest pain and smoking history at the time of MPI were predictive of cardiac events. Patients with positive ECG and negative EX-MPI results have low risk for cardiac events. Nevertheless, the cardiac events cannot be excluded totally in some

  20. Prognosis of patients with positive exercise test and normal myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Ahn, B. C.; Lee, J.; Lee, K. B

    2004-01-01

    Exercise SPECT myocardial perfusion imaging(Ex-MPI) is regarded as a predictive technique particularly in patients with coronary artery disease(CAD) capable of performing exercise testing. In clinical practice, we encounter equivocal situations of discordant findings between exercise ECG and MPI. We evaluated the prognosis of subjects with positive ECG and normal MPI findings, and predictive factors for cardiac events. 2571 Ex-MPI studies were reviewed over a period of 3 years. Subjects were followed for more than 2 years(24-56 months, mean 35±10months) for cardiac events after study. The cardiac events were defined as hard events(cardiac death and nonfatal myocardial infarction(MI)) and soft events(aggravation of CAD necessitating revascularization, congestive heart failure necessitating hospital admission). We evaluated age, sex, typical angina pain, rest ECG, hypertension, diabetes mellitus(DM), serum levels of cholesterol and LDL, smoking history, history of cerebrovascular disease(CVD) and peripheral artery disease(PAD), and rest left ventricular ejection fraction(LVEF) as clinical variables. Of 83 subjects with positive ECG and normal MPS findings, 6 were considered as false negative results confirmed with coronary angiography. There were 77 patients (mean age 52±10 years, 39 males) with positive ECG and normal MPI results. During the follow-up period, of 77 there were 3 cardiac events (annual rate 1.9%), no cardiac death, 2 nonfatal MIs (annual rate 1.3%) and 1 soft event (annual rate 0.6%). 2/39 males(5.1%), and 1/38 females(2.6%) had cardiac events. All cardiac events were observed within 2 years. 1-year cardiac event rate was 0.6% and 2-year cardiac event rate was 1.9%. Among clinical factors, male sex, typical chest pain and smoking history at the time of MPI were predictive of cardiac events. Patients with positive ECG and negative EX-MPI results have low risk for cardiac events. Nevertheless, the cardiac events cannot be excluded totally in some

  1. Evaluation of coronary hemodynamics and exercise 201Tl-myocardial scintigraphy in patients with vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Haiyama, Tohru; Hasegawa, Akira; Saito, Takayuki

    1992-01-01

    To clarify the coronary hemodynamics and myocardial perfusion in patients with vasospastic angina, we performed exercise 201 Tl-myocardial scintigraphy (planar and SPECT) in 72 patients and left coronary digital subtraction angiography (DSA) in 37 patients without significant organic coronary artery stenosis. Coronary artery spasm was documented by coronary angiography in all patients. Fifty-four patients (75%) developed exercise-induced 201 Tl-myocardial perfusion defect on SPECT. 201 Tl pulmonary uptake (L/H) was significantly increased in patients with vasospastic angina. Especially, L/H was higher in patients with multiple small perfusion defect on 201 Tl-SPECT, so that exercise-induced left ventricular dysfunction existed in patients with vasospastic angina and especially in cases of multiple small perfusion defect on 201 Tl-SPECT. The left coronary circulation time (CCT) was prolonged in patients with vasospastic angina. The mechanism of prolonged CCT is still unknown, but we suspected that prolonged CCT was induced by increased peripheral coronary vascular resistance in patients with vasospastic angina. It was concluded that the peripheral coronary circulation was disturbed in patients with vasospastic angina, but its abnormal coronary circulation had no relation to location of spasm-induced vessels. We concluded that impaired coronary microcirculation was taken a part of pathophysiology in vasospastic angina. (author)

  2. Clinical implications of diffuse slow washout of thallium-201 in exercise stress myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru (Sumitomo Hospital, Osaka (Japan))

    1991-07-01

    Clinical implications of diffuse slow washout of thallium-201 (DSWO) in exercise-redistribution myocardial SPECT were studied. Thallium-201 washout rate was calculated by Bull's-eye method. DSWO was defined as having abnormal thallium-201 washout rate (<30% per 3 hours) in more than two thirds of each coronary artery (CA) area. Of 974 patients whose exercise heart rate exceeded 120/min, 51 (5.2%) showed DSWO and coronary angiography was performed in 43. Twenty-three patients (53%) showed triple vessel disease (3VD), 8 (19%) showed single or double vessel disease (1VD/2VD) and 12 (28%) showed normal CA. Patients with normal CA consisted of 6 patients with hypertrophic cardiomyopathy (HCM), 5 with hypertension (HT) and one with electrocardiographic abnormality only. The cause of DSWO were assessed from the history of effort angina (EA) and congestive heart failure (CHF), delayed fill-in of the perfusion defect and the ratio of lung to heart thallium-201 activity (L/M) at exercise as an indicator of the left ventricular (LV) function. High prevalence of EA (74%), high incidence of scintigraphic delayed fill-in (83%) and normal L/M suggested diffuse LV ischemia as the cause of DSWO in 3VD. On the other hand in patients with 1VD/2VD, LV dysfunction at exercise was considered as the cause of DSWO because of low prevalence of EA (13%) and scintigraphic delayed fill-in (13%)(p<0.01, p<0.005 each vs 3VD), and high L/M (p<0.001 vs 3VD) and high prevalence of CHF (38%, NS). In patients with HCM LV ischemia at small vessel levels was assumed as the cause of DSWO from the high incidence of EA (83%) and delayed fill-in (50%), low L/M and normal CA. In cases of HTLV dysfunction and/or LV ischemia at the small vessel levels were considered as the cause of DSWO. Thus, it was concluded that DSWO is a noteworthy finding in exercise stress myocardial imaging. (author).

  3. Prognostic value of gated 201Tl myocardial perfusion SPECT imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li Zicheng; Chen Xiaoming; Xu Hao

    2006-01-01

    Objective: To study the prognostic value of gated 201 Tl myocardial perfusion SPECT imaging in patients with coronary artery disease and assessment of therapy strategy for the individual patient. Methods: Eighty-four patients underwent rest and exercise stress 201 Tl gated myocardial perfusion SPECT imaging and were followed up for (32.92 ± 16.77) months. Images were studied using 17 segments and 1 to 4 scoring. Global summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS=SSS-SRS) were also calculated. Post-stress and rest ejection fraction (EF) were automatically measured. Results: Nine cardiac events occurred (3.90% per year). SSS, SDS, SRS and EF were the independent predictors of cardiac events (P 201 Tl myocardial perfusion SPECT imaging can provide prognostic assessment for the patients with coronary artery disease and guide in selection of therapeutic strategy. Among all of the indices SSS is the best predictors of cardiac events. (authors)

  4. Prognostic value of stress 99Tcm-MIBI myocardial perfusion SPECT after acute myocardial infarction

    International Nuclear Information System (INIS)

    Sui Xutao; Chen Zhi; Gao Shenghai; Shen Li; Li Shang'ai

    2003-01-01

    Objective: To investigate relativity of acute myocardial infarction (AMI) with clinical, stress test and perfusion imaging parameters and to assess predictive value on hard events of cardiac death or recurrent nonfatal AMI. Methods: One hundred and one patients of AMI underwent stress 99 Tc m -MIBI SPECT before discharge. Hard and soft events were followed-up, relative factors with cardiac events were analyzed by statistical methods and predictive value on hard events were assessed. Results: Independent predictors by multivariate analysis for cardiac hard events or all cardiac events consisted of a history of prior AMI (RR=5.30, CI 2.17-12.98), a low exercise capacity (RR=6.28, CI 1.92-21.46) and left ventricular ejection fraction 99 Tc m -MIBI SPECT is a single test that can provide exercise parameter, cardiac perfusion imaging information and left ventricular function assessment to identify high-risk and estimate hard prognosis at discharge of AMI patients. These high-risk patients can be referred for early invasive evaluation and intervention

  5. Myocardial perfusion scintigraphy with exercise and pharmacological stress

    Energy Technology Data Exchange (ETDEWEB)

    Sundram, F X [General Hospital of Singapore, Dept. of Nuclear Medicine (Senegal)

    1996-12-31

    Cardiac studies including myocardial perfusion scintigraphy was begun in the Singapore General Hospital, nuclear medicine department in 1983. From a few patients per year using planar imaging, we have in 1994 studied 1500 patients for myocardial perfusion, using mainly SPECT (single-photon emission computerised tomography) and radionuclides such as Thallium-201, Technetium-99m sestamibi and Tc-99m tetrofosmin. Patients have been stressed using treadmill exercise or pharmacological agents; we have used dipyridamole, and dobutamine for pharmacological stress but have no experience with intravenous adenosine.

  6. Myocardial perfusion scintigraphy with exercise and pharmacological stress

    International Nuclear Information System (INIS)

    Sundram, F.X.

    1995-01-01

    Cardiac studies including myocardial perfusion scintigraphy was begun in the Singapore General Hospital, nuclear medicine department in 1983. From a few patients per year using planar imaging, we have in 1994 studied 1500 patients for myocardial perfusion, using mainly SPECT (single-photon emission computerised tomography) and radionuclides such as Thallium-201, Technetium-99m sestamibi and Tc-99m tetrofosmin. Patients have been stressed using treadmill exercise or pharmacological agents; we have used dipyridamole, and dobutamine for pharmacological stress but have no experience with intravenous adenosine

  7. Clinical evaluation of stress thallium spect in ischemic heart disease

    International Nuclear Information System (INIS)

    Sui, Osamu; Kimura, Nazuna; Soeki; Takeshi; Takeichi, Naoki; Shinohara, Hisanori; Tamura, Yoshiyuki; Fukuda, Nobuo

    1997-01-01

    Thallium SPECT was performed in patients with significant coronary artery stenosis, 67 cases were after maximal exercise and 74 cases were during coronary vasodilation induced by ATP (adenosine triphosphate) infusion. In patients suspected of angina pectoris, the sensitivity, specificity and predictive accuracy for detection of coronary artery disease (CAD) were 88%, 78% and 82% for exercise SPECT, and 100%, 72% and 84% for ATP SPECT studies, respectively. In patients with old myocardial infarction, these were 73%, 100% and 88% for exercise SPECT and 71%, 100% and 81% for ATP SPECT. These were 75%, 49% and 60% for treadmill exercise test in the patient group including both angina and myocardial infarction. For detection of diseased vessels, the diagnostic accuracy for left anterior descending artery and right coronary artery lesions was almost equal for ATP and exercise SPECT study, but ATP SPECT study was more sensitive than exercise SPECT study in detection of left circumflex artery lesions. ATP as well as exercise SPECT studies occasionally gave false positive results in patients with single-vessel disease. ATP as well as exercise SPECT studies underestimated the severity of multi-vessel disease. In general, the results of ATP SPECT imaging were highly concordant with the results of exercise SPECT imaging. ATP stress thallium SPECT imaging provided a safe and highly accurate diagnostic tool for detection of CAD. (author)

  8. Clinical evaluation of the Tl-201 ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Mochizuki, Teruhito

    1989-01-01

    In order to evaluate the clinical usefulness of the Tl-201 ECG-gated myocardial single photon emission computed tomography (SPECT), we compared the wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT with the wall motion of the ECG-gated blood pool SPECT. Materials were 87 patients of 50 old myocardial infarctions (OMIs), 19 hypertrophic cardiomyopathies (HCMs), 2 dilated cardiomyopathies (DCMs) and 16 others. After intravenous injection of 111-185 MBq (3-5 mCi) of Tl-201 at rest, the projection data were acquired using a rotating gamma-camera through 180deg, from RAO 45deg in 24 directions, each of which consisted of 80-100 beats. For the reconstruction of ED, ES and non-gated images, R-R interval was divided into about 20 (18-22) fractions. In 348 regions of interest (anterior, septal, lateral and inferior wall) in 87 cases, wall motion and the Tl-201 uptake were evaluated to three grades (normal, hypokinesis and akinesis; normal, low and defect, respectively), which were compared with the wall motion of the ECG-gated blood pool SPECT. The wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT correlated well with the wall motion of the ECG-gated blood pool SPECT (96.6% and 87.9%, respectively). In conclusion, the ECG-gated myocardial SPECT can provide clear perfusion images and is a very useful diagnostic strategy to evaluate the regional wall motion and perfusion simultaneously. (author)

  9. Myocardial fatty acid utilisation during exercise induced ischemia in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Virtanen, K.S.; Nikkinen, P.; Lindroth, L.; Kuikka, J.T.

    2002-01-01

    Aim: Reversible or irreversible myocardial damage due to ischemia correlates with altered membrane functions of the cells. To compare myocardial free fatty acid (FFA) metabolism and flow during exercise induced ischemia we studied ten patients with coronary artery disease but without previous myocardial infarction. Methods: A series of post-exercise single-photon emission computed tomography (SPECT) measurements was performed after injection of 123 I labelled heptadecanoic acid (HDA). Myocardial perfusion was estimated from the separately performed exercise-redistribution thallium study. Fatty acid metabolic rate, thallium uptake and washout were calculated for anterior, lateral, posterior and septal segments. Results: The more reduced post-exercise FFA metabolic rate (-63±18%, mean ±1 SD) compared to flow (-36±16%) was related to the severity of myocardial ischemia and wall motion abnormalities. Conclusion: In this small group of patients, the reduced post-exercise FFA metabolic rate tentatively suggests a parsimonious workload of the exercising myocardium by reducing oxygen consumption in patients with coronary artery disease. (orig.) [de

  10. Study of sympathetic nervous function under effort induced ischemia in patients with angina pectoris with I-123 metaiodobenzylguanidine (MIBG) myocardial SPECT images

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori; Kato, Kazuzo; Ogasawara, Ken; Sakuma, Toru; Kirigaya, Hajime; Hirosaka, Akira; Igarashi, Masaki

    1990-01-01

    I-123 metaiodobenzylguanidine (MIBG) is a norepinephrine analog, which can be used to study the sympathetic nervous function of the heart. With MIBG myocardial SPECT images sympathetic nervous function under effort induced ischemia were studied in 18 patients with significant coronary artery lesions. In 5 patients with effort induced ischemic region in stress Tl-201 myocardial images rest MIBG images were collected and then exercise stress test was performed. Patients continued exercising for 3 minutes after onset of symptom. Post-stress MIBG images were collected. Definite ischemic region was noted in stress Tl-201 myocardial images, however no differences were noted between rest and post-stress MIBG images. These results suggested that exercise induced ischemia did not enhance release of uptaken MIBG. In 13 patients with significant coronary artery lesions symptom-limited exercise stress test was performed MIBG and Tl-201 were simultaneously injected at onset of symptom and patients continued exercising for an additional one minute. In 6 cases (46%, 6/13) MIBG defects with Tl-201 uptake were noted. These results showed that exercise induced ischemia depressed net MIBG uptake and that sympathetic nervous function (MIBG images) may be more sensitive to ischemic damage than muscle (Tl-201 images). It is suggested that exercise induced ischemia depressed reuptake of norepinephrine at sympathetic nervous endings. MIBG myocardial SPECT images may be useful for evaluating sympathetic nervous function under ischemia. (author)

  11. The diagnostic value of Tc-99m PYP, Tl-201 dual isotope SPECT to predict the viability of damaged myocardium in the acute phase of myocardial infarction

    International Nuclear Information System (INIS)

    Matsuo, Hitoshi; Watanabe, Sachiro; Arai, Masazumi

    1991-01-01

    To assess the diagnostic value of Tc-99m pyrophosphate (PYP), Tl-201 dual isotope SPECT for the evaluation of myocardial viability, segmental comparison between dual isotope SPECT and exercise, delayed, and reinjected Tl study were performed with 18 acute myocardial infarction (AMI) patients. Among 72 damaged myocardial segments, 48 segments (67%) were judged as viable by chronic phase Tl studies. The segments with severely reduced Tl uptake by dual SPECT showed significantly lower prevalence of viable myocardium than the segments with reduced and normal Tl uptake (p<0.001). The segments with PYP accumulation localized to the subendocardium represented the favorable outcome compared with the transmural accumulation (p<0.001). And overlap segments show better prognosis than the segments without overlap (p<0.05). Most importantly, we can get better predictive accuracy of myocardial scar by dual isotope SPECT than the judgement by Tl or PYP SPECT alone (83.3% vs 77.8%, 68.1%). Thus, we conclude that Tc-99m PYP, Tl-201 dual isotope SPECT is useful to assess the severity of myocardial damage in the acute phase of myocardial infarction. (author)

  12. Characteristics of 201Tl myocardial SPECT and left ventriculography in patients with acute diagonal branch myocardial infarction

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori; Katou, Kazuzo; Ogasawara, Ken; Kirigaya, Hajime

    1993-01-01

    Characteristics of 201 Tl myocardial SPECT and ventriculography were studied in 13 patients with acute diagonal branch myocardial infarction. Rest 201 Tl myocardial SPECT and left ventriculography were underwent in chronic phase. In 5 patients electrocardiogram (ECG) changes in acute phase were not definite. In 6 patients it was difficult to identify the obstructed coronary artery with coronary angiography in acute phase. Mean value of maximum creatine phosphokinese (CPK) was 854 (458-1,774) U/l. It seemed to be difficult to diagnose acute diagonal branch myocardial infarction with ECG and/or coronary angiography. In all patients defects were noted on 201 Tl SPECT. Defects were small and noted in the central anterior wall and not in the septum. In 2 patients defects were noted at apex. In left ventriculography dyskinetic motion was noted in 10 patients; one patient showed apical aneurysm and 3 patients showed anterior wall aneurysm. In 3 patients anterior wall showed akinesis. It was concluded that 201 Tl myocardial SPECT were useful for detecting diagonal branch lesion. In case of diagonal branch myocardial infarction size of defects were small and defects were not noted in the septum, however aneurysmal motion was frequently noted. (author)

  13. Interrelation of ST-segment depression during bicycle ergometry and extent of myocardial ischaemia by myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Muzzarelli, Stefano; Pfisterer, Matthias Emil; Zellweger, Michael Johannes; Mueller-Brand, Jan

    2009-01-01

    The aim of this study was to compare ST-segment depression (STD) during bicycle ergometry and extent of myocardial ischaemia assessed by myocardial perfusion SPECT (MPS) in a large patient cohort. Consecutive patients (n = 955) referred for MPS with bicycle ergometry and interpretable stress ECG were evaluated with respect to ECG and MPS findings of ischaemia. The maximal STD was recorded and exercise ECG was considered ischaemic if STD was horizontal or downsloping (≥1 mm). MPS was interpreted using a 20-segment model with a scale of 0 to 4. A summed stress (SSS), summed rest (SRS) and summed difference score (SDS = SSS-SRS, e.g. extent of ischaemia) were derived. Ischaemia was defined as an SDS ≥ 2. An exercise-induced STD was present in 215 patients (22%) and myocardial ischaemia on MPS was present in 366 patients (38%). The extent of ST-segment depression and the number of ECG leads with significant STD were each strongly and significantly associated with increasing severity of ischaemia and the number of coronary territories involved (p < 0.01 for all correlations). These data demonstrate a strong correlation between the extent of STD, number of ischaemic leads and severity of myocardial ischaemia as assessed by MPS during bicycle ergometry. (orig.)

  14. Interrelation of ST-segment depression during bicycle ergometry and extent of myocardial ischaemia by myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Muzzarelli, Stefano; Pfisterer, Matthias Emil; Zellweger, Michael Johannes [University Hospital Basel, Cardiology Department, Basel (Switzerland); Mueller-Brand, Jan [University Hospital Basel, Nuclear Medicine Department, Basel (Switzerland)

    2009-11-15

    The aim of this study was to compare ST-segment depression (STD) during bicycle ergometry and extent of myocardial ischaemia assessed by myocardial perfusion SPECT (MPS) in a large patient cohort. Consecutive patients (n = 955) referred for MPS with bicycle ergometry and interpretable stress ECG were evaluated with respect to ECG and MPS findings of ischaemia. The maximal STD was recorded and exercise ECG was considered ischaemic if STD was horizontal or downsloping ({>=}1 mm). MPS was interpreted using a 20-segment model with a scale of 0 to 4. A summed stress (SSS), summed rest (SRS) and summed difference score (SDS = SSS-SRS, e.g. extent of ischaemia) were derived. Ischaemia was defined as an SDS {>=} 2. An exercise-induced STD was present in 215 patients (22%) and myocardial ischaemia on MPS was present in 366 patients (38%). The extent of ST-segment depression and the number of ECG leads with significant STD were each strongly and significantly associated with increasing severity of ischaemia and the number of coronary territories involved (p < 0.01 for all correlations). These data demonstrate a strong correlation between the extent of STD, number of ischaemic leads and severity of myocardial ischaemia as assessed by MPS during bicycle ergometry. (orig.)

  15. Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin % wall thickening. Comparison with F-18 FDG-PET

    International Nuclear Information System (INIS)

    Maruyama, Atsushi; Hasegawa, Shinji; Paul, A.K.; Xiuli, M.; Yoshioka, Jun; Maruyama, Kaoru; Hori, Masatsugu; Nishimura, Tsunehiko

    2002-01-01

    This study was designed to assess the value of gated SPECT Tc-99m-tetrofosmin (TF) wall thickening (WT) in addition to TF exercise (Ex)/rest myocardial SPECT, in comparison with F-18 fluorodeoxyglucose (FDG)-PET. The study population consisted of 33 patients with old myocardial infarction (27 men and 6 women; mean age, 62±8 years old). All patients underwent Ex/rest TF SPECT and glucose loading FDG-PET. Polar map images of Ex/rest TF were generated and divided into 24 segments for further analysis. We classified LV segments according to the exercise-rest perfusion scintigraphy. LV segments with less than 70% of the maximum TF activity on the exercise image were defined as stress-induced defects. Among these, the segments whose TF acitvity increased by 10% from exercise to rest images or exceeded 70% of the maximum uptake were defined as reversible (viable) defects. The remaining defects on the rest image were irreversible (non-viable) defect segments, and were considered for viability study on the basis of %WT. %WT was calculated according to the standard method: {(counts ES-counts ED)/ counts ED} x 100. A viable segment on gated SPECT was defined as a segment whose %WT exceeded the lower limit of the normal value (mean-SD). PET viability was defined as FDG uptake exceeding 50% of the maximum count. Among the 792 segments evaluated in the 33 patients studied, there were 689 PET viable segments. Of the 689 segments analyzed, 198 (29%) were identified as having defects on Ex images. Among these defects, 55 (8%) were reversible or partially reversible, as evidenced by rest images, and 143 (21%) were irreversible. Of the irreversible segments on Ex/rest images, 106 (15%) demonstrated no apparent WT by gated TF SPECT, whereas 37 (6%) segments with irreversible defects did have apparent WT. Overall, the sensitivity of Ex/rest TF perfusion imaging was 79%. Sensitivity was improved from 79% to 85% by combining %WT and perfusion data, but specificity was reduced from 70

  16. Myocardial fatty acid utilisation during exercise induced ischemia in patients with coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Virtanen, K.S. [First Dept. of Medicine, Helsinki Univ. Central Hospital (Finland); Nikkinen, P. [Dept. of Clinical Chemistry, Helsinki Univ. Central Hospital (Finland); Lindroth, L. [Medix Diacor Lab. Services, Ltd., Espoo (Finland); Kuikka, J.T. [Dept. of Clinical Physiology and Nuclear Medicine, Kuopio Univ. Hospital, Univ. of Kuopio and Niuvanniemi Hospital, Kuopio (Finland)

    2002-06-01

    Aim: Reversible or irreversible myocardial damage due to ischemia correlates with altered membrane functions of the cells. To compare myocardial free fatty acid (FFA) metabolism and flow during exercise induced ischemia we studied ten patients with coronary artery disease but without previous myocardial infarction. Methods: A series of post-exercise single-photon emission computed tomography (SPECT) measurements was performed after injection of {sup 123}I labelled heptadecanoic acid (HDA). Myocardial perfusion was estimated from the separately performed exercise-redistribution thallium study. Fatty acid metabolic rate, thallium uptake and washout were calculated for anterior, lateral, posterior and septal segments. Results: The more reduced post-exercise FFA metabolic rate (-63{+-}18%, mean {+-}1 SD) compared to flow (-36{+-}16%) was related to the severity of myocardial ischemia and wall motion abnormalities. Conclusion: In this small group of patients, the reduced post-exercise FFA metabolic rate tentatively suggests a parsimonious workload of the exercising myocardium by reducing oxygen consumption in patients with coronary artery disease. (orig.) [German] Ziel: Bei reversibler und irreversibler Myokardschaedigung infolge Ischaemie sind die Membranfunktionen der Zellen veraendert. Um myokardialen Metabolismus freier Fettsaeuren (FFA) und Durchblutung bei belastungsinduzierter Ischaemie zu vergleichen, untersuchten wir zehn Patienten mit Koronarinsuffizienz, aber ohne vorangegangenen Myokardinfarkt. Methoden: Nach Injektion von {sup 123}I-markierter Heptadekansaeure (HDA) wurde eine Serie von SPECT-Messungen nach Belastung aufgenommen. Die myokardiale Perfusion wurde abgeschaetzt durch die separat durchgefuehrte Thalliumverteilungsstudie nach Belastung. Fettsaeurestoffwechsel, Thallium-Uptake und -Washout wurden fuer die anterioren, posterioren und septalen Segmente berechnet. Ergebnisse: Eine eingeschraenktere FFA-Stoffwechselrate (-63{+-}18%, {+-}1 SD

  17. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E.; El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria; Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke; Kroft, Lucia J.; Younis, Imad Al; Reiber, Johan H.; Scholte, Arthur J.

    2013-01-01

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 ± 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS ≥2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p 2 = 20.7) and lesion length (χ 2 = 26.0) to the clinical variables and the visual assessment (χ 2 = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have incremental value over baseline variables and visually assessed significant stenosis. Potentially, QCT can refine assessment of CAD, which may be of potential use for identification of patients with myocardial ischaemia. (orig.)

  18. Comparison of adenosine stress and exercise stress 201Tl myocardial perfusion imaging for diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Chen Guibing; Wu Hua; Jiang Ningyi; Liu Sheng; Lu Xianping; Liang Jiugen; Zhang Hong

    2007-01-01

    Objective: The aim of this study was to compare the diagnostic values of adenosine and exercise stress 201 Tl myocardial perfusion imaging for detecting coronary heart disease (CHD). Methods: 41 patients with suspected CHD were randomly divided into two groups. In one group adenosine stress was submitted, the exercise stress myocardial SPECT was performed in another. Coronary angiography (CAG) was performed in each patient within 2 weeks before or after SPECT. The result of CAG was taken as 'gold standard of CHD. They compared the diagnostic value of two methods. Results: In adenosine group, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy are 92.86%, 57.14%, 81.25%, 80.00%, 80.95% respectively. In exercise stress group, are 100%, 60.0%, 71.43%, 100%, 80.00% respectively. Detection rates of coronary artery lesions were 66.67% and 72.22% in two groups respectively. Conclusion Adenosine stress testing and exercise stress testing 201 Tl myocardial perfusion imaging may provide similar value for detection of CHD. (authors)

  19. [Myokard-Perfusions-SPECT. Myocardial perfusion SPECT - Update S1 guideline].

    Science.gov (United States)

    Lindner, Oliver; Bengel, Frank; Burchert, Wolfgang; Dörr, Rolf; Hacker, Marcus; Schäfer, Wolfgang; Schäfers, Michael A; Schmidt, Matthias; Schwaiger, Markus; Vom Dahl, Jürgen; Zimmermann, Rainer

    2017-08-14

    The S1 guideline for myocardial perfusion SPECT has been published by the Association of the Scientific Medical Societies in Germany (AWMF) and is valid until 2/2022. This paper is a short summary with comments on all chapters and subchapters wich were modified and amended.

  20. Prognostic value of myocardial perfusion SPECT imaging in elderly patients without history of coronary artery disease and low prevalence of them

    International Nuclear Information System (INIS)

    Arja, V.J.; Balestrini, V.R.; Sandrin, A.L.; Conci, E.C.; Serra, C.M.; Joekes, S.

    2002-01-01

    Elderly patients without history of coronary artery disease are difficult to characterized because the clinical symptoms are often atypical, occult or absent. On the other hand, these patients frequently cannot achieve adequate level of exercise during stress testing and this limitation can compromise the diagnostic and prognostic ability of the test. Generally the prognostic value of myocardial perfusion SPECT is well established for a general population but not for elderly patients. Aim: This study assessed the prognostic value of Tc99m-sestamibi SPECT in a group of patients older than 65 years with low prevalence of coronary artery disease. Material and Methods: Population: 161 consecutive patients older than 65 years without history of coronary artery disease and low prevalence of them were studied with Tc99m-sestamibi SPECT perfusion imaging. Mean age 71 years old (65-87), male 55%, mean pretest likelihood 11%. Risk factors: diabetes 17%, high blood pressure 74%, high cholesterol 45%, smokers 88%. Stress test: bicycle exercise 39% and dipyridamole 61%. Myocardial perfusion SPECT: semiquantitative analysis to evaluate perfusion defects with a 14-segments model and 4-point scoring system for uptake reduction. Scintigraphic indices: SSS (sum of the stress scores), SRS (sum of the rest scores) and SDS (SSS-SRS). Follow up: cardiac events: hard (acute myocardial infarction and cardiac death) and soft (need for PTCA/CABG and angina). Results: Mean follow up: 508 days. Events rate: hard 0.6% (1 acute myocardial infarction), soft 5.6%. Univariate analysis identified sex (p=0.017) and SDS (p=0.009) as cardiac events predictors. Complete or reduced (independent variables which predicted events) logistic regression analysis correctly predicted the absence of events but did not predict the presence of events. Conclusion: In this elderly population with a low clinical risk where the stress test is a suboptimal method of study for coronary artery disease, semiquantitative

  1. Evaluation of viability of infarcted myocardium by low dose dobutamine stress echocardiography. Comparison with exercise stress 201Tl myocardial scintigraphy

    International Nuclear Information System (INIS)

    Nagahara, Toshihiro; Sakamoto, Kazunori; Sofue, Akira; Horiuchi, Toshimitsu; Yamazaki, Shigeki; Kuwako, Kenji

    1999-01-01

    Exercise stress 201 Tl myocardial single-photon emission computed tomography (SPECT) is recognized to be a excellent method for identifying viability after myocardial infarction, but it is expensive and needs a longer time for data acquisition than echocardiography. We therefore performed this study to evaluate the effectiveness of low dose (5-10 μg/kg/min) dobutamine stress echocardiography (DSE) in 30 patients (61±8 years old: 24 men and 6 women) within 4 weeks after myocardial infarction in identifying viable myocardium, compared to results obtained by SPECT. Defining an akinetic or dyskinetic segment obtained by rest echocardiography as a definite infarct area, altogether 96 segments out of 716 segments were shown to be infarct areas. Of these, 75 (78%) segments were identified as viable by DSE, and 77 (80%) by SPECT. Only 2 segments were shown to be discrepant on DSE and SPECT. Subsequently, the sensitivity, specificity and accuracy rates for DSE were 96%, 100% and 96%, respectively. In conclusion, DSE is as effective and useful as SPECT in the evaluation of viability after myocardial infarction. (author)

  2. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); The Interuniversity Cardiology Institute of The Netherlands, Utrecht (Netherlands); El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Kroft, Lucia J. [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Younis, Imad Al [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Reiber, Johan H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical imaging systems B.V., Leiden (Netherlands); Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands)

    2013-08-15

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 {+-} 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS {>=}2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p < 0.001, and OR 1.07, 95 % CI 1.00-1.45, p = 0.032, respectively) after correcting for clinical variables and visually assessed significant stenosis. The addition of quantitatively assessed significant stenosis ({chi} {sup 2} = 20.7) and lesion length ({chi} {sup 2} = 26.0) to the clinical variables and the visual assessment ({chi} {sup 2} = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have

  3. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-01-01

    201 Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by 201 Tl myocardial SPECT was high, and 201 Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author)

  4. Comparison with myocardial perfusion MRI and myocardial perfusion SPECT in the diagnostic performance of coronary artery disease. A meta-analysis

    International Nuclear Information System (INIS)

    Iwata, Kunihiro; Kubota, Makoto; Ogasawara, Katsuhiko

    2008-01-01

    We compared the diagnostic abilities of stress myocardial perfusion MRI (myocardial perfusion MRI) and myocardial perfusion single photon emission computed tomography (SPECT), using a meta-analysis method. We investigated the diagnostic abilities of MRI and SPECT in similar subject groups in reports written in English or Japanese. The reports to be used for analysis were selected according to a ''screening standard,'' which was established in advance. After consolidating the data from the selected reports, we compared the integrated odds ratio, the point estimation values of sensibility/specificity, and the summary receiver operating characteristic (ROC) curve. For the analysis, six reports were selected (subjects: 153, coronary-artery target sites: 447). Meta-analysis revealed that the diagnostic ability of myocardial perfusion MRI was superior to that of myocardial perfusion SPECT regarding each of the parameters. This is considered to be supportive evidence of the usefulness of myocardial perfusion MRI. (author)

  5. [Performance of Thallium 201 rest-redistribution spect to predict viability in recent myocardial infarction].

    Science.gov (United States)

    Coll, Claudia; González, Patricio; Massardo, Teresa; Sierralta, Paulina; Humeres, Pamela; Jofré, Josefina; Yovanovich, Jorge; Aramburú, Ivonne; Brugère, Solange; Chamorro, Hernán; Ramírez, Alfredo; Kunstmann, Sonia; López, Héctor

    2002-03-01

    The detection of viability after acute myocardial infarction is primordial to select the most appropriate therapy, to decrease cardiac events and abnormal remodeling. Thallium201 SPECT is one of the radionuclide techniques used to detect viability. To evaluate the use of Thallium201 rest-redistribution SPECT to detect myocardial viability in reperfused patients after a recent myocardial infarction. Forty one patients with up to of 24 days of evolution of a myocardial infarction were studied. All had angiographically demonstrated coronary artery disease and were subjected to a successful thrombolysis, angioplasty or bypass grafting. SPECT Thallium201 images were acquired at rest and after 4 h of redistribution. These results were compared with variations in wall motion score, studied at baseline and after 3 or 4 months with echocardiography. The sensitivity of rest-redistribution Thallium201 SPECT, to predict recovery of wall motion was 91% when patient analysis was performed and 79% when segmental analysis was done in the culprit region. The figures for specificity were 56 and 73% respectively. Rest-distribution Thallium201 SPECT has an excellent sensitivity to predict myocardial viability in recent myocardial infarction. The data obtained in this study is similar to that reported for chronic coronary artery disease.

  6. Quantitative estimation of myocardial thickness by the wall thickness map with Tl-201 myocardial SPECT and its clinical use

    International Nuclear Information System (INIS)

    Sekiai, Yasuhiro; Sawai, Michihiko; Murayama, Susumu

    1988-01-01

    To estimate the wall thickness of left ventricular myocardium objectively and quantitatively, we adopted the device of wall thickness map (WTM) with Tl-201 myocardial SPECT. For validation on measuring left ventricular wall thickness with SPECT, fundamental studies were carried out with phantom models, and clinical studies were performed in 10 cases comparing the results from SPECT with those in echocardiography. To draw the WTM, left ventricular wall thickness was measured using the cut off method from SPECT images obtained at 5.6 mm intervals from the base and middle of left ventricle: short-axis image for the base and middle of left ventricle and vertical and horizontal long-axis images for the apical region. Wall thickness was defined from the number of pixel above the cut off level. Results of fundamental studies disclosed that it is impossible to evaluate the thickness of less than 10 mm by Tl-201 myocardial SPECT but possible to discriminate wall thickness of 10 mm, 15 mm, and 20 mm by Tl-201 myocardial SPECT. Echocardiographic results supported the validity of WTM, showing a good linear correlation (r = 0.96) between two methods on measuring wall thickness of left ventricle. We conclude that the WTM applied in this report may be useful for objective and quantitative estimation of myocardial hypertrophy. (author)

  7. ATP-loading 201Tl myocardial SPECT for the detection of ischemic heart disease

    International Nuclear Information System (INIS)

    Fujinaga, Tsuyoshi; Yamazaki, Sayaka; Hara, Masatada; Umezawa, Chiaki; Okamura, Tetsuo; Murata, Hajime; Maruno, Hirotaka; Onoguchi, Masahisa.

    1993-01-01

    To evaluate the usefulness for the detection of ischemic heart disease, ATP myocrdial SPECT was performed in 35 patients (mean; 59±9.4 years) with angina pectoris or old myocardial infarction. Coronary angiography (CAG) was performed in all patients. The ultra-short half-life of ATP required a continuous infusion for its use. ATP was infused intravenously at a rate of 0.16 mg/kg/min for 5 min, with 201 Tl injection taking place at 3 min. Myocardial SPECT imaging was begun 5 min and 4 hr later after the end of ATP infusion. ATP caused a significant decrease in arterial blood pressure (p 201 Tl myocardial SPECT for the detection of coronary artery disease (CAD) was evaluated using CAG as a golden standard. The sensitivity and specificity for CAD detection were 82% and 90%, respectively. ATP myocardial SPECT is a promising new test for the detection of ischemic heart disease. (author)

  8. Detection of coronary artery disease with exercise 99Tcm-MIBI SPECT in patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Yang Minfu; Guo Xinhua; He Zuoxiang; Tou Kefei; Yang Yuejin

    2007-01-01

    Objective: To investigate the ability of exercise myocardial perfusion imaging (MPI) for detecting coronary artery disease (CAD) in patients with atrial fibrillation (AF). Methods: Fifty-eight consecutive patients with AF during symptom-limited exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) SPECT imaging were retrospectively analyzed. All patients underwent coronary angiography within an interval of 90 d. Results: The overall diagnostic sensitivity, specificity and accuracy of exercise 99 Tc m -MIBI SPECT were 60% (9/15), 88% (38/43) and 81% (47/58), respectively. Among patients without valvular disease, the diagnostic sensitivity and specificity were 60% (9/15) and 96% (22/23). The diagnostic accuracy was 80% (16/20) in patients with valvular heart disease. Conclusion: In patients with AF during exercise test, exercise MPI has a moderate sensitivity and an excellent specificity in detection of CAD to those without valvular disease, and has a high diagnostic accuracy in patients with valvular heart disease. (authors)

  9. Assessment of left ventricular function by 201Tl FCG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Toba, Masahiro; Ishida, Yoshio; Fukuchi, Kazuki; Fukushima, Kazuhito; Katafuchi, Tetsurou; Hayashida, Kohei; Oka, Hisashi; Takamiya, Makoto

    1999-01-01

    We applied the QGS program for LV function analysis (described by Germano, 1995) to a 201 Tl SPECT study at rest, and estimated its accuracy. We performed 201 Tl ECG-gated myocardial SPECT in 25 patients with ischemic heart disease under an acquisition time used in the routine 99m Tc ECG-gated SPECT study. The quality of the gated images was visually assessed with a 4-point grading system. LVEDV, LVESV, LVEF determined by the QGS program were compared with those by Simpson's method on biplane LVG in 25 patients. Regional wall motion scores in 7 myocardial segments were assessed on the three-dimensional display created by the QGS program and the cine display of biplane LVG with a 5-point grading system. Wall motion scores obtained by the QGS program were compared with those by LVG. Although 72.0% of 201 Tl ECG-gated SPECT images were fair or poor in image quality, there were good correlations between the values obtained by the QGS program and LVG (LVEDV: r=0.82, LVESV: r=0.88, LVEF: r=0.89). In addition, wall motion scores by the QGS program were correspondent to those by LVG in 77.1% of all 175 myocardial segments. We conclude that the QGS program provides high accuracy in evaluating left ventricular function even from 201 Tl ECG-gated myocardial SPECT data. (author)

  10. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by /sup 201/Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-03-01

    /sup 201/Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by /sup 201/Tl myocardial SPECT was high, and /sup 201/Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author).

  11. Quantitative comparison of dobutamine and exercise stress 99mTc-MIBI myocardial SPECT in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Wu, H.; Liu, H.C.

    2002-01-01

    Aim: To compare the value of dobutamine and exercise stress 99m Tc-MIBI myocardial imaging in diagnosis of coronary heart disease (CHD). Material and Methods: The subjects included twenty-one patients, in whom 18 were suspected with CHD and 3 were clinically diagnosed with myocardial infarction. The final diagnosis in all patients was confirmed by coronary angiography. Both dobutamine stress (DOB-ST) and bicycle exercise stress (EX-ST) 99m Tc-MIBI myocardial perfusion SPECT were undertaken in every patient. The two stress imaging in one patient were performed within three days. Results: Twenty-four vessels in fourteen patients were diagnosed with coronary artery disease. There were no significant difference between DOB-ST and EX-ST in overall sensitivity (92.8% vs 92.8%), specificity (71.4 vs 85.7%), positive predictive value (86.7% vs 92.9%) and negative predictive value (83.3 vs 85.7%). There were also no significant difference in the sensitivity and specificity for detecting single or multiple vessel disease and for detecting specified vessel lesions (LDA, RCA, LCX). However, in 69 segments which related to the diseased vessels DOB-ST revealed 47 ischemic segments and EX-ST found 30 ischemic segments (P<0.05). The ischemic size which was expressed by the percentage of black-out area in polar map were bigger in DOB-ST image than that in EX-ST image (22.8±11.4% vs 17.5±12.3%, P<0.01) and, average radioactivity uptake ratio of ischemic region in DOB-ST image was lower than that in EX-ST image (43.2±13.8% vs 57.4±14.6%, P<0.01). Conclusion: DOB-ST demonstrated similar diagnostic efficacy to EX-ST in detecting coronary artery disease, thus it may be a feasible intervention for myocardial perfusion imaging. Whether DOB-ST is more sensitive to detect mild ischemia than EX-ST remains to be further investigated

  12. Myocardial perfusion after prolonged submaximal exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Flotats, A.; Mena, E.; Camacho, V.; Tembl, A.; Hernandez, M.A.; Estorch, M.; Carrio, I.; Serra-Grima, R.

    2002-01-01

    Aim: Exercise training in patients with coronary artery disease (CAD) has established benefits. We assessed myocardial perfusion after submaximal but prolonged exercise in patients with CAD, who were enrolled in supervised exercise rehabilitation programs. Material and Methods: Nine patients with CAD enrolled in supervised exercise rehabilitation programs (7 men, 2 women; mean age 54±9 years), 7 with prior AMI and 2 with re-vascularized (CABG) multiple vessel disease, were encouraged to walk/run actively around the perimeter of our Hospital during the annual social sporting event organised in our Institution. Patients were studied by means of perfusion Tc-99m tetrofosmin SPECT imaging after prolonged exercise and at rest (gated SPECT), for two consecutive years. All patients remained symptom free during this interval period. Quantitative analysis was performed dividing polar map images in 13 segments. Tracer activity 9% in the resting image. The analysis was focused on those segments showing perfusion defects. Results: No symptoms other than fatigue were registered during prolonged exercise (range 1-2 hr). There were no significant differences in distance covered (7,462±3,031 m vs. 8,456±2,998 m), heart rate (92±11 bpm vs. 85±13 bpm) and rate-pressure product at the end of exercise (10,804±2,467 vs. 10,403±2,955) or gated SPECT calculated LVEF (44%±19 vs. 46%±20) between the two consecutive annual sporting events. Tracer activity in segments with perfusion defects did not significantly differ between both events. Overall agreement between both examinations regarding patient classification as having scar/ischemia was 77% (kappa=0.49). There was one patient who showed partial reversibility in three segments, consistent with mild anteroapical ischemia, only in the first examination. On the other hand, another patient showed reversibility in one segment (medium septum), only in the second examination, when he covered a distance 1.3 times superior. Conclusions

  13. Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X

    International Nuclear Information System (INIS)

    Saghari, Mohsen; Assadi, Majid; Eftekhari, Mohammad; Yaghoubi, Mohammad; Fard-Esfahani, Armaghan; Malekzadeh, Jan-Mohammad; Sichani, Babak Fallhi; Beiki, Davood; Takavar, Abbas

    2006-01-01

    Cardiac syndrome X is defined by a typical angina pectoris with normal or near normal (stenosis <40%) coronary angiogram with or without electrocardiogram (ECG) change or atypical angina pectoris with normal or near normal coronary angiogram plus a positive none-invasive test (exercise tolerance test or myocardial perfusion scan) with or without ECG change. Studies with myocardial perfusion imaging on this syndrome have indicated some abnormal perfusion scan. We evaluated the role of myocardial perfusion imaging (MPI) and also the severity and extent of perfusion abnormality using Tc-99m MIBI Single Photon Emission Computed Tomography (SPECT) in these patients. The study group consisted of 36 patients with cardiac syndrome X. The semiquantitative perfusion analysis was performed using exercise Tc-99m MIBI SPECT. The MPI results were analyzed by the number, location and severity of perfusion defects. Abnormal perfusion defects were detected in 13 (36.10%) cases, while the remaining 23 (63.90%) had normal cardiac imaging. Five of 13 (38.4%) abnormal studies showed multiple perfusion defects. The defects were localized in the apex in 3, apical segments in 4, midventricular segments in 12 and basal segments in 6 cases. Fourteen (56%) of all abnormal segments revealed mild, 7(28%) moderate and 4 (16%) severe reduction of tracer uptake. No fixed defects were identified. The vessel territories were approximately the same in all subjects. The Exercise treadmill test (ETT) was positive in 25(69%) and negative in 11(30%) patients. There was no consistent pattern as related to the extent of MPI defects or exercise test results. Our study suggests that multiple perfusion abnormalities with different levels of severity are common in cardiac syndrome X, with more than 30 % of these patients having at least one abnormal perfusion segment. Our findings suggest that in these patients microvascular angina is probably more common than is generally believed

  14. Role of myocardial perfusion SPECT in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Cho, I.; Chun, K.; Won, K.; Lee, H.; Park, J.; Shin, D.; Kim, Y.; Shim, B.; Lee, J.

    2002-01-01

    Purpose: It is important that early diagnosis and treatment of coronary artery disease in diabetic patients, but there are few reports on the prevalence of stress-induced myocardial perfusion abnormalities and the rates of cardiac event in patients with type 2 diabetes. We evaluated the scan findings on gated myocardial perfusion SPECT in asymptomatic diabetic patients. Methods: We performed pharmacological stress test and gated perfusion SPECT in 69 diabetic patients without cardiovascular symptom (mean age: 65 year, male 31 and female 38). Patients underwent two-day imaging protocol and stress study was performed injection of Tc-99m MIBI during adenosine infusion. We followed up these patients by reviewing medical records. Results: Fifty-two of 69 patients (74.5%) showed normal scan findings and 17 patients (24.6%) showed reversible or fixed perfusion defects. Three of 52 patients with normal scan findings showed decreased LV ejection fraction and decreased wall motion. Twenty-three patients with normal scan findings were possible to follow up for more than 1yr (mean time: 18.3±3.3 mo.) and they all had no cardiac event. Three patients with reversible perfusion defects were performed coronary angioplasty. Conclusion: Myocardial perfusion SPECT is a noninvasive method and maybe useful in early diagnosis and predicting prognosis in diabetic patients

  15. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Tamura, Takuhisa; Shibuya, Noritoshi; Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke.

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD≥10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD≥10 and age≥15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age≥15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author)

  16. Comparison between unstable angina pectoris and stable effort angina pectoris by using 123I-BMIPP and 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Hisatake, Shinji; Yamashina, Shohei; Yamazaki, Junichi

    2004-01-01

    We performed BMIPP myocardial SPECT and Tl myocardial SPECT in patients with unstable angina (UAP) and stable effort angina (SAP), and compared the results for the two groups. Our subjects were 30 patients with the UAP and 25 patients with the SAP. The early and delayed images of the BMIPP were obtained with patients at rest. The early image of the Tl alone was obtained with patients at rest. We calculated severity score (SS) using the polar map based on SPECT short-axis image on the both myocardial SPECT. And, we calculated % uptake of the responsible coronary lesion and regional washout rate (WR) on myocardial SPECT with BMIPP. On coronary angiogram, no difference in % diameter stenosis was seen between the two groups. On myocardial SPECT with Tl, no difference in the SS was seen between the two groups. However, on myocardial SPECT with BMIPP, the SS was significantly higher score in the UAP group than in the SAP group. And, on myocardial SPECT with BMIPP, the % uptake and the WR were significant lower values in the UAP group than in the SAP group. Even if the two groups have almost the same level of myocardial perfusion disorder, the UAP group may have severer myocardial fatty-acid metabolic disorder than the SAP group, because the defects in BMIPP were significantly severer in the UAP group. (author)

  17. Myocardial Infarction Area Quantification using High-Resolution SPECT Images in Rats

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luciano Fonseca Lemos de [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Mejia, Jorge [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Carvalho, Eduardo Elias Vieira de; Lataro, Renata Maria; Frassetto, Sarita Nasbine [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Fazan, Rubens Jr.; Salgado, Hélio Cesar [Departamento de Fisiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Galvis-Alonso, Orfa Yineth [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Simões, Marcus Vinícius, E-mail: msimoes@fmrp.usp.br [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-07-15

    Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. To determine the accuracy of this system for quantification of myocardial infarct area in rats. Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq of 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.

  18. Addition of atropine to submaximal exercise stress testing in patients evaluated for suspected ischaemia with SPECT imaging: a randomized, placebo-controlled trial

    International Nuclear Information System (INIS)

    Manganelli, Fiore; Sauro, Rosario; Di Lorenzo, Emilio; Rosato, Giuseppe; Spadafora, Marco; Varrella, Paola; Peluso, Giuseppina; Daniele, Stefania; Cuocolo, Alberto

    2011-01-01

    To evaluate the effects of the addition of atropine to exercise testing in patients who failed to achieve their target heart rate (HR) during stress myocardial perfusion imaging with single-photon emission computed tomography (SPECT). The study was a prospective, randomized, placebo-controlled design. Patients with suspected or known coronary artery disease who failed to achieve a target HR (≥85% of maximal predicted HR) during exercise SPECT imaging were randomized to receive intravenous atropine (n = 100) or placebo (n = 101). The two groups of patients did not differ with respect to demographic or clinical characteristics. A higher proportion of patients in the atropine group achieved the target HR compared to the placebo group (60% versus 3%, p < 0.0001). SPECT imaging was abnormal in a higher proportion of patients in the atropine group as compared to the placebo group (57% versus 42%, p < 0.05). Stress-induced myocardial ischaemia was present in more patients in the atropine group as compared to placebo (47% versus 29%, p < 0.01). In both groups of patients, no major side effects occurred. The addition of atropine at the end of exercise testing is more effective than placebo in raising HR to adequate levels, without additional risks of complications. The use of atropine in patients who initially failed to achieve their maximal predicted HR is associated with a higher probability of achieving a diagnostic myocardial perfusion study. (orig.)

  19. Assessment of inferior wall in 123I-metaiodobenzylguanidine myocardial SPECT in diabetic patients

    International Nuclear Information System (INIS)

    Fukumoto, Yoshihiro; Kuroda, Yasuhisa; Ohta, Jun; Osono, Ken; Saitou, Miyoko; Suzuki, Mituaki; Nakajima, Toshiki

    1994-01-01

    A phantom experiment and a clinical assessment have been made with the purpose of investigating the causes of low accumulation and deficiency of the inferior wall in 123 I-metaiodobenzylguanidine (MIBG) myocardial SPECT and the method for its evaluation. By the phantom experiment, assessments were made regarding (1) influence of the liver positioned adjacently; and (2) involvement of absorption and attenuation of the inferior wall. For the clinical assessment, 84 patients with diabetes in whom no abnormality was observed by exercise myocardial SPECT ( 201 TlCl) and 5 cases of inferior myocardial infarction (OMI group) were adopted as subjects. The inferior walls were evaluated as visually deficient because of the adjacently-positioned liver, but no low value was exhibited by quantitative evaluation. By pulmonary mediastinal phantom (-), improvement of the inferior wall was observed visually and quantitatively, compared with pulmonary mediastinal phantom (+). By quantitative evaluation, the patients were classified into normal MIBG group (N group); segmentally deficient group (S group); and non-accumulated group (DH group). In addition, S group was classified by severity score into those from S 1 to S 4 groups. No significant difference was observed in Relative Regional Uptake (RRU) in the inferior wall between S 4 group and OMI group. To sum up, we considered the causes for low accumulation and deficiency of the inferior wall, (1) adjacently-positioned liver; (2) absorption and attenuation; and (3) the lesion itself. Visual evaluation is not sufficient as the evaluating method. Quantitative evaluation becomes necessary. (author)

  20. Prediction of 6-year prognosis for cardiac event by thallium-201 single-photon emission computed tomography (SPECT) with treadmill exercise test

    International Nuclear Information System (INIS)

    Hayashi, Katsumi; Ohsuzu, Fumitaka; Kosuda, Shigeru; Nakamura, Haruo

    1997-01-01

    To examine thallium-201 single-photon emission computed tomography (SPECT) with a treadmill exercise test can predict the long-term prognosis of patients with coronary artery disease, 95 patients (71 men, 24 women) who underwent a treadmill exercise test with thallium-201 SPECT from April to December 1986 were followed for 6 years. Three short-axis slices at the apical, mid- and basal-level were selected, and each slice was divided into eight segments. Each segment count was assigned a score according to the count range in the slice (score 0, count range 76-100%; 1, 51-75%; 2, 26-50%; 3, 1-25%; 4, 0%) by evaluating the mean value of the slice. The total Tl defect score of each segment in 3 slices was summed (ΣTl defect score). The 'early ΣTl defect score' was the ΣTl defect score 5 min after treadmill exercise, and the 'late ΣTl defect score' was ΣTl defect score measured 4 h after treadmill exercise. Cardiac events occurred in 27 of the 95 patients: cardiac death 3; myocardial infarction 1; percutaneous transluminal angioplasty 16; coronary artery bypass graft 5; congestive heart failure 3. Univariate analysis showed that previous myocardial infarction (p<0.01), exercise work load (p<0.05), early ΣTl defect score (p<0.0l) and late ΣTl defect score (p<0.01) were independent predictors of the prognosis. These results suggest that thallium-201 SPECT with the treadmill exercise test could be applicable and useful to predict long term prognosis. (author)

  1. The usefulness of preoperative exercise stress myocardial single photon emission CT with thallium-201 to predict the responses to coronary revascularization

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Minamino, Takazoh; Katoh, Osamu; Higashino, Yorihiko.

    1989-01-01

    To evaluate the usefulness of preoperative exercise stress (Ex) myocardial single photon emission CT (SPECT) with thallium-201 to predict the responses to coronary revascularization (CRV), Ex-SPECT's were obtained in 42 patients with coronary artery disease (CAD). In 34 patients angioplasty was performed and in 18 patients coronary bypass surgery was undergone. Before and after CVR, Ex-SPECT's were obtained both at immediately after Ex (Initial) and 3 hours later (RD) by the rotating gamma camera. Initial images before CRV showed definite perfusion defects (+3) in 76 myocardial segments. Perfusion abnormalities at RD images were graded into (+3 to 0) by visual interpretation. '+3' indicated fixed defect and '0' indicated no perfusion abnormality. At RD images 17 segments showed fixed defect and 59 segments showed improved perfusion more than one grade. After CRV, all 59 segments with improved perfusion at RD images showed improvement of perfusion in comparison with initial images before CRV. Out of 17 segments with fixed defect before CRV, 14 segments showed perfusion defect with +3, while 3 segments showed improved perfusion after CRV. These 3 segments had ECG evidence of myocardial infarction. In these 3 segments, Ex-SPECT's before CRV showed abnormally low myocardial Tl washout rate (WOR) despite they indicated fixed defect visually. On the contrary, other 14 segments with fixed defect showed normal WOR before CRV. In conclusion, visually interpreted Ex-SPECT's before CRV predict the myocardial perfusion after CRV in most of cases. In a small number (especially infarction segments) Ex-SPECT's before CRV cannot predict the improvement of myocardial perfusion after CRV by visual inspection, but WOR abnormality before CRV is useful to prospect their results. (author)

  2. The usefulness of myocardial SPECT for the preoperative cardiac risk evaluation in noncardiac surgery

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Lee, Dong Soo; Kang, Won Jon; Chung, June Key; Lee, Myung Chul

    1999-01-01

    We investigated whether myocardial SPECT had additional usefulness to clinical, functional or surgical indices for the preoperative evaluation of cardiac risks in noncardiac surgery. 118 patients ( M: F=66: 52, 62.7±10.5 years) were studied retrospectively. Eighteen underwent vascular surgeries and 100 nonvascular surgeries. Rest Tl-201/ stress Tc-99m-MIBI SPECT was performed before operation and cardiac events (hard event: cardiac death and myocardial infarction; soft event: ischemic ECG change, congestive heat failure and unstable angina) were surveyed through perioperative periods (14.6±5.6 days). Clinical risk indices, functional capacity, surgery procedures and SPECT findings were tested for their predictive values of perioperative cardiac events. Peri-operative cardiac events occurred in 25 patients (3 hard events and 22 soft events). Clinical risk indices, surgical procedure risks and SPECT findings but functional capacity were predictive of cardiac events. Reversible perfusion decrease was a better predictor than persistent decrease. Multivariate analysis sorted out surgical procedure risk (p=0.0018) and SPECT findings (p=0.0001) as significant risk factors. SPECT could re-stratify perioperative cardiac risks in patients ranked with surgical procedures. We conclude that myocardial SPECT provides additional predictive value to surgical type risks as well as clinical indexes or functional capacity for the prediction of preoperative cardiac events in noncardiac surgery

  3. Clinical efficacy of 99mTc-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Adachi, Itaru; Sugioka, Yasushi; Tanaka, Yasunori

    1993-01-01

    99m Tc-tetrofosmin is a lipophilic, cationic diphosphine which has been developed for myocardial imaging. We examined 9 patients with ischemic heart disease including 3 angina pectoris (AP), 4 old myocardial infarction (OMI), 1 AP with OMI and 1 syndrome X. One patient was examined before and after operation. Three hundred seventy MBq of 99m Tc-tetrofosmin was injected during exercise and 740 MBq at rest. And 74 MBq of 201 Tl myocardial exercise and redistribution scintigraphy was also performed to compare with 99m Tc-tetrofosmin myocardial scintigraphy. SPECT, multiple gated SPECT and anterior planar images were obtained in all cases. We calculated percent wall thickening (%WT) using multiple gated SPECT images. There was a decreased lung uptake in 99m Tc-tetrofosmin planar images compared to 201 Tl myocardial scintigraphy. Liver and Biliary system uptake in 99m Tc-tetrofosmin images was decreased with intake of milk. Segmental comparison of SPECT images showed an agreement in 9/10 of the segment between 201 Tl and 99m Tc-tetrofosmin. We could obtain excellent quality of multiple gated SPECT images in all patients. We could calculate percent wall thickening (%WT) in all patients. We conclude that 99m Tc-tetrofosmin myocardial scintigraphy should provide usefulness for detection of ischemic myocardium as same as 201 Tl myocardial scintigraphy, although the biologic characteristics of two agents were different. These data and excellent quality of multiple gated SPECT images suggest that 99m Tc-tetrofosmin is a new 99m Tc agent for evaluation of patients with ischemic heart disease. (author)

  4. Clinical usefulness of delayed exercise images on 99mTc-tetrofosmin myocardial SPECT in the diagnosis of vasospastic angina pectoris

    International Nuclear Information System (INIS)

    Ito, Kazuki; Zen, Kan; Hikosaka, Takatou; Adachi, Yoshihiko; Yoneyama, Satoshi; Katoh, Shuuji; Sugihara, Hiroki; Nakamura, Tomoki; Azuma, Akihiro

    2000-01-01

    This study was designed to evaluate the clinical usefulness of delayed exercise images in 99m Tc-tetrofosmin (TF) myocardial SPECT in the diagnosis of vasospastic angina pectoris. We studied 30 patients with vasospastic angina, 10 of 30 patients (group A) had both effort and rest angina, 20 of 30 patients (group B) had rest angina. A 370 MBq of TF was intravenously injected at peak exercise, and initial (EX-I) and delayed exercise (EX-D) images were obtained at 30 min and 180 min after the injection. An additional 740 MBq of TF was intravenously reinjected after EX-D image acquisition, and rest images were obtained 30 min after the reinjection. The left ventricular wall was divided into 9 segments. Regional myocardial uptakes of TF were scored by 4-point defect score (0=normal, 1=mildly reduced, 2=moderately reduced, and 3=severely reduced). Total defect score (TDS) was calculated from the sum of defect scores in 9 segments. Reverse redistribution (RR) was defined as increase of more than 2 in TDS on EX-D images. In group A, 4 of 10 cases (40%) showed decreased uptake on EX-I images, 6 of 10 cases (60%) revealed RR on EX-D images, and none of the patients showed decreased uptake on rest images. In group B, no one showed decreased uptake on EX-I and rest images, 11 of 20 cases (55%) revealed RR on EX-D images. The mean±SD of TDS were 2.9±3.4, 5.1±4.5, 0.5±0.5 on EX-I, EX-D, rest images in group A, and serially 0.4±0.5, 3.3±3.6, 0.4±0.5 in group B. Regional wall motion abnormality was reduced in regions with RR. RR on EX-D images may reflect ischemic damaged but viable myocardium in vasospastic angina. The clinical usefulness of exercise-rest TF imaging in detection of organic coronary artery disease has been well established. Therefore, exercise-rest TF imaging with additional delayed exercise image could evaluate not only organic coronary artery disease but also coronary artery vasospasm. (author)

  5. Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior wall defects

    International Nuclear Information System (INIS)

    Segall, G.M.; Davis, M.J.

    1989-01-01

    Artifactual inferior wall defects as a result of diaphragmatic attenuation of activity are a frequent source of error in thallium myocardial single photon emission computed tomography (SPECT) studies. Thirty-four patients and 11 clinically normal volunteers were studied prospectively to see if specificity of inferior wall defects for right coronary artery disease could be improved by scanning patients prone versus supine. All individuals were scanned both prone and supine, in random order, following symptom limited treadmill exercise. Images were acquired at 3 degrees steps, 25 sec per frame, in a 180 degrees elliptical orbit always beginning in the 45 degrees right anterior oblique position relative to the patient. Polar maps generated from the short axis slices were used to calculate the average regional activity. The prone studies showed consistently higher inferior wall activity compared to the supine studies on both the exercise (182 +/- 22 vs. 160 +/- 23, p less than or equal to 0.001) and 4-hr delay studies (183 +/- 20 vs. 175 +/- 21, p less than or equal to 0.001). Prone imaging resulted in a significantly higher specificity for RCA disease compared to supine imaging (90% vs. 66%, p less than 0.05) with an improvement in accuracy from 71% to 82%. Sensitivity, specificity, and accuracy for left anterior descending and left circumflex artery disease were not significantly affected by patient position during imaging. All patients having SPECT thallium myocardial perfusion studies should be imaged prone to minimize artifactual inferior wall defects and improve accuracy

  6. Prognostic value of myocardial perfusion SPECT images in combination with the maximal heart rate at exercise testing in Japanese patients with suspected ischemic heart disease. A sub-analysis of J-ACCESS

    International Nuclear Information System (INIS)

    Ueshima, Kenji; Usami, Satoru; Yasuno, Shinji; Nakao, Kazuwa; Yamashina, Akira; Nishiyama, Osamu; Yamazaki, Takuya; Nishimura, Tsunehiko

    2009-01-01

    We assessed whether a combination of summed stress scores (SSS) using exercise myocardial perfusion single photon emission computed tomography (SPECT) (Ex-SPECT) and maximal heart rate accurately predicts cardiac events through a sub-analysis of J-ACCESS (Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT) which was conducted to evaluate the prognosis of Japanese patients with suspected ischemic heart disease. In J-ACCESS, 2,373 patients with suspected coronary artery disease not receiving beta-blocker treatment underwent Ex-SPECT. These patients were categorized into the following four groups: Group A [achieved target heart rate (THR) and SSS<4: n=631], B (did not achieve THR and SSS<4: n=612), C (achieved THR and SSS≥4: n=570), and D (did not achieve THR and SSS≥4: n=560). We evaluated the incidence rate of cardiac events including cardiac death, myocardial infarction, and heart failure requiring hospital admission during a 3-year period. In Group A, B, C, and D, 9 of 631 (1.4%), 15 of 612 (2.4%), 23 of 570 (4.0%) and 30 of 560 (5.4%) patients experienced cardiac events, respectively. Although the hazard ratio of the SSS≥4 was 2.45 (p<0.001) and that of the attained THR was 0.69 (p=0.10) in the multiple Cox regression analysis, Kaplan-Meier curves showed that the cardiac events rate was lower in the order of A, B, C, and D (p<0.001). The combination of SSS using Ex-SPECT and the maximal heart rate is a useful predictor of cardiac events in patients with suspected coronary artery disease. (author)

  7. Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123)I-labeled fatty acid analog.

    Science.gov (United States)

    Nanasato, M; Ando, A; Isobe, S; Nonokawa, M; Hirayama, H; Tsuboi, N; Ito, T; Hirai, M; Yokota, M; Saito, H

    2001-12-01

    Electrocardiographically (ECG) gated myocardial SPECT with (99m)Tc-tetrofosmin has been used widely to assess left ventricular (LV) function. However, the accuracy of variables using ECG gated myocardial SPECT with beta-methyl-p-(123)I-iodophenylpentadecanoic acid (BMIPP) has not been well defined. Thirty-six patients (29 men, 7 women; mean age, 61.6 +/- 15.6 y) with ischemic heart disease underwent ECG gated myocardial SPECT with (123)I-BMIPP and with (99m)Tc-tetrofosmin and left ventriculography (LVG) within 1 wk. LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), and LV end-systolic volume (LVESV) were determined on gated SPECT using commercially available software for automatic data analysis. These volume-related items on LVG were calculated with an area-length method and were estimated by 2 independent observers to evaluate interobserver validity. The regional wall motion with these methods was assessed visually. LVEF was 41.1% +/- 12.5% on gated SPECT with (123)I-BMIPP, 44.5% +/- 13.1% on gated SPECT with (99m)Tc-tetrofosmin, and 46.0% +/- 12.7% on LVG. Global LV function and regional wall motion between both gated SPECT procedures had excellent correlation (LVEF, r = 0.943; LVEDV, r = 0.934; LVESV, r = 0.952; regional wall motion, kappa = 0.92). However, the correlations of global LV function and regional wall motion between each gated SPECT and LVG were significantly lower. Gated SPECT with (123)I-BMIPP showed the same interobserver validity as gated SPECT with (99m)Tc-tetrofosmin. Gated SPECT with (123)I-BMIPP provides high accuracy with regard to LV function and is sufficiently applicable for use in clinical SPECT. This technique can simultaneously reveal myocardial fatty acid metabolism and LV function, which may be useful to evaluate various cardiac diseases.

  8. Correlation between left ventricular filling and ischemic extent during exercise-induced myocardial ischemia

    International Nuclear Information System (INIS)

    Ando, Akitada; Yokota, Mitsuhiro; Iwase, Mitsunori

    1993-01-01

    The aim of this study was to determine how the extent of exercise-induced myocardial ischemia influence left ventricular filling. Twenty-two consecutive patients with effort angina, consisting of 16 with single vessel disease and 6 with double vessel disease, underwent exercise studies in lying and sitting positions. Extent score (ES) and severity score (SS) were calculated on polar map prepared from early exercise Tl-201 myocardial SPECT images to determine ischemic extent. Pulmonary arterial wedge pressure (PAWP), as obtained at exercise in lying position, correlated significantly well with both ES (r=0.75, p<0.001) and SS (r=0.61, p<0.01). There was, however, no significant correlation between the other hemodynamic parameters, such as heart rate, systolic pressure, rate-pressure product, cardiac index and stroke index, and both ES and SS. Either increased PAWP or ischemic extent was not dependent on the number of diseased vessels. In conclusion, the extent of increased left ventricular filling did not correlate with the number of diseased vessels, but correlated positively with ischemic extent. (N.K.)

  9. Attenuation correction of myocardial SPECT by scatter-photopeak window method in normal subjects

    International Nuclear Information System (INIS)

    Okuda, Koichi; Nakajima, Kenichi; Matsuo, Shinro; Kinuya, Seigo; Motomura, Nobutoku; Kubota, Masahiro; Yamaki, Noriyasu; Maeda, Hisato

    2009-01-01

    Segmentation with scatter and photopeak window data using attenuation correction (SSPAC) method can provide a patient-specific non-uniform attenuation coefficient map only by using photopeak and scatter images without X-ray computed tomography (CT). The purpose of this study is to evaluate the performance of attenuation correction (AC) by the SSPAC method on normal myocardial perfusion database. A total of 32 sets of exercise-rest myocardial images with Tc-99m-sestamibi were acquired in both photopeak (140 keV±10%) and scatter (7% of lower side of the photopeak window) energy windows. Myocardial perfusion databases by the SSPAC method and non-AC (NC) were created from 15 female and 17 male subjects with low likelihood of cardiac disease using quantitative perfusion SPECT software. Segmental myocardial counts of a 17-segment model from these databases were compared on the basis of paired t test. AC average myocardial perfusion count was significantly higher than that in NC in the septal and inferior regions (P<0.02). On the contrary, AC average count was significantly lower in the anterolateral and apical regions (P<0.01). Coefficient variation of the AC count in the mid, apical and apex regions was lower than that of NC. The SSPAC method can improve average myocardial perfusion uptake in the septal and inferior regions and provide uniform distribution of myocardial perfusion. The SSPAC method could be a practical method of attenuation correction without X-ray CT. (author)

  10. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B

    2004-01-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP

  11. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2004-07-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP.

  12. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Takuhisa; Shibuya, Noritoshi (Kawatana National Hospital, Nagasaki (Japan)); Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD[>=]10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD[>=]10 and age[>=]15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age[>=]15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author).

  13. Diagnosis of silent myocardial ischemia in type 2 diabetic patients by electrocardiogram, ergometry and Gated-SPECT

    International Nuclear Information System (INIS)

    Penna Quian, Yamile; Fernandez-Britto Rodriguez, Jose; Bacallao Gallestey, Jorge; Batista Cuellar, Juan Felipe; Coca Perez, Marco Antonio; Toirac Garcia, Noresma; Penna Coego, Andria

    2008-01-01

    31 asymptomatic type 2 diabetic patients were studied by lab tests, electrocardiogram, ergometry, Gated-SPECT and coronariography to determine the relation between the atherosclerotic risk factors and the silent myocardial ischemia. Patients were classified into two groups: positive SPECT and negative SPECT. Association tests were made for each variable and ROC curves were constructed to identify risk markers. In 35.5% of the patients silent myocardial ischemia was detected with a good angiographic correlation. A significant association was evidenced between positive SPECT and the atherosclerotic risk factors, namely, low values of HDLc, family pathological history of ischemic heart disease and peripheral vascular disease. The logistic regression models showed that low values of HDLc together with family pathological history of ischemic heart disease may be strong predictors of silent myocardial ischemia in asymptomatic type 2 diabetic patients

  14. The clinical usefulness of myocardial thallium-201 washout rate after exercise stress

    International Nuclear Information System (INIS)

    Iwasaki, Tsutomu; Takino, Yutaka; Sakurai, Fumio

    1989-01-01

    Myocardial Tl-201 Washout rates (WORs) after exercise stress were measured in 15 normal subjects and 67 patients with coronary artery disease (CAD) or chest pain syndrome and the usefulness of WOR for the detection of CAD was studied. Myocardial tomograms were obtained both immediately after exercise and 3 hours later using a rotating gamma camera in 15 normal subjects and 67 patients. After low-pass filtering, images were reconstructed into short-axis, horizontal long-axis and vertical long-axis tomograms and visually interpreted. By using short-axis tomograms, left ventricle WORs were expressed as circumferential profile curves at the apex, center and base of the ventricle. Lower normal limits of the WOR were set at 2 SDs from the mean of the normal subjects. The combination of visual interpretation of SPECT with WOR increased the sensitivity of detection of CAD from 8.3% to 66.7% in patients with three-vessel CAD without losing specificity. WOR after exercise stress is believed to be a useful method of detecting multivessel CAD. (author)

  15. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    International Nuclear Information System (INIS)

    Verger, Antoine; Karcher, Gilles; Djaballah, Wassila; Fourquet, Nicolas; Rouzet, Francois; Le Guludec, Dominique; Koehl, Gregoire; Roch, Veronique; Imbert, Laetitia; Poussier, Sylvain; Fay, Renaud; Marie, Pierre-Yves

    2013-01-01

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving 201 Tl (n = 120) or 99m Tc-sestamibi injected at low dose at stress ( 99m Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ( 99m Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, 201 Tl 92 %, 99m Tc-Low 86 %, 99m Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p 201 Tl or 99m Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 ± 101 kcounts) and dramatically enhanced with CZT SPECT (+279 ± 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  16. Normal value of functional parameters in gated myocardial perfusion SPECT in patients with low risk of coronary artery disease: emory cardiac tool box program

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. Y.; Kim, M. H.; Kim, Y. D.; Kim, D. K. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    Absolute value of the functional data of gated myocardial perfusion SPECT is necessary to determine that individual patient is normal or not. Tc-99m MIBI gated myocardial perfusion SPECT was performed using emory cardiac tool box program. All patients (M:F=15:36, age 64{+-}10 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded; previous angina or MI, ECG change with Q wave or ST-T change, diabetes mellitus, hypercholesterolemia, typical chest pain and hypertension. In all patients, myocardial mass is 117{+-}23 g in stress gated SPECT, 106{+-}22 g in stress ungated SPECT and 102{+-}21 g in rest ungated SPECT. EDV is 90{+-}28 ml, ESV 26{+-}20 ml, SV 66{+-}21 ml, EF 73{+-}10 % and TID 1.06{+-}0.14. Myocardial mass in rest ungated SPECT is significantly different between men and women (p=0.025). Myocardial mass is significantly different between stress gated SPECT and stress ungated SPECT (p=0.000), and between stress ungated SPECT and rest ungated SPECT (p=0.003). We provide normal value of functional parameters to determine the abnormality of individual patients in patients with low risk of coronary artery disease.

  17. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae

    2005-01-01

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 ± 8.5%, range:3 ∼ 35%) and mild to moderate severity (-71 ± 42.7%, range:-217 ∼ -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome

  18. Abnormal perfusion on myocardial perfusion SPECT in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Cha, Kwang Soo; Han, Seung Ho; Park, Tae Ho; Kim, Moo Hyun; Kim, Young Dae [Donga University College of Medicine, Busan (Korea, Republic of)

    2005-02-15

    Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkison-White) syndrome. Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECT with Fitzpatrick's algorithm of electrophysiologic study and radiofrequency catheter ablation. Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients(mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent (11.0 {+-} 8.5%, range:3 {approx} 35%) and mild to moderate severity (-71 {+-} 42.7%, range:-217 {approx} -39%) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patients with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but if did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome.

  19. The accuracy of myocardial perfusion SPECT imaging in the evaluation of coronary artery disease in women and men

    International Nuclear Information System (INIS)

    Kaminek, M.; Myslivecek, M.; Huyak, V.; Koranda, P.; Skvarilova, M.; Ostransky, J.

    2001-01-01

    The purpose of this study is to compare sensitivity, specificity and accuracy of myocardial perfusion SPECT for the detection of coronary artery disease (CAD) in women and men. 588 patients (455 males and 133 females, 273 after a previous myocardial infarction) underwent stress myocardial perfusion SPECT. The accuracy of myocardial perfusion SPECT was proved by coronary angiography (stenosis >50% was considered as a CAD). The sensitivity of SPECT was slightly higher, but statistically not significant, in men than in women (94% versus 91%, p > 0.05). The specificity was higher in women than in men (93% versus 82%), but this difference was not statistically significant either (p > 0.05). The accuracy of SPECT was the same for both sexes (92%). In angiographically verified group of patients the selection bias was obvious - patients with CAD dominated (74%) and the fraction of patients with CAD in men's group (83%) was significantly higher than in women's group (50%), p < 0.05. No significant difference was revealed in the accuracy of myocardial perfusion SPECT in men and women. Our results are in accordance with the prevailing opinion in literature that discovered differences in sensitivity, specificity and diagnostic accuracy are usually not statistically significant or that they can be explained by the selection bias of patients in angiographically verified groups (significantly higher fraction of patients with CAD in men's group). (author)

  20. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    Science.gov (United States)

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR

  1. Automatic extraction of left ventricle in SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Liu Li; Zhao Shujun; Yao Zhiming; Wang Daoyu

    1999-01-01

    An automatic method of extracting left ventricle from SPECT myocardial perfusion data was introduced. This method was based on the least square analysis of the positions of all short-axis slices pixels from the half sphere-cylinder myocardial model, and used a iterative reconstruction technique to automatically cut off the non-left ventricular tissue from the perfusion images. Thereby, this technique provided the bases for further quantitative analysis

  2. Clinical usefulness of the technetium-99m/thallium-201 overlap on simultaneous dual SPECT in reperfusion after thrombolytic therapy for acute myocardial infarction

    International Nuclear Information System (INIS)

    Suzuki, Kazuo

    2002-01-01

    In this study, the clinical usefulness of the technetium-99m/thallium-201 ( 99m Tc-PYP/ 201 Tl-Cl) overlap on simultaneous dual SPECT in reperfusion after thrombolytic therapy for acute myocardial infarction was evaluated. The subjects were 14 patients with acute myocardial infarction who had not had myocardial infarction. All patients had chest pain that persisted more than 1 hour and showed electrocardiographic ST elevation. Myocardial scintigraphy was performed on the 4th day of the attack, at 81±35 hours after reperfusion on average. Three hours 50 min after intravenous injection of 740 Mbq 99m Tc-PYP, 111 Mbq 201 Tl-Cl was intravenously injected, and simultaneous dual SPECT was performed after 10 min. In all short axis SPECT image which showed 99m Tc-PYP accumulation, the area of 99m Tc-PYP accumulation (Tc hot), the overlap area of 99m Tc-PYP and 201 Tl-Cl accumulation (overlap), and the total area of 99m Tc-PYP and 201 Tl-Cl accumulation in the short axis SPECT images were calculated. The relationships between these parameters and the peak creatinine kinase (CK), changes in wall motion abnormalities observed by M-mode echocardiography, and the 4-hour delayed image by 201 Tl-Cl exercise scintigraphy performed about one month after the attack were evaluated. The results were both parameters of overlap/Tc hot and overlap/total were negatively correlated with the peak CK, overlap/Tc hot and overlap/total were positively correlated with wall motion scores ratio (WMSR), and overlap/Tc hot was positively correlated with Tl uptake (d)/Tc hot, and the acute overlap region was evaluated to be viable cardiac muscles one month after the attack. These results demonstrated that the 99m Tc-PYP/ 201 Tl-Cl overlap on simultaneous dual SPECT in reperfusion after thrombolytic therapy for acute myocardial infarction indicates the presence of viable cardiac muscles, showing that this method is useful for judgment of the effects of reperfusion. (author)

  3. Diagnostic value of transesophageal atrial pacing myocardial perfusion imaging in coronary artery disease

    International Nuclear Information System (INIS)

    Jia Yongping; Li Zhiling; Li Yunqian

    1994-01-01

    Transesophageal atrial pacing (TAP) SPECT myocardial perfusion imaging (MPI) with 99m Tc-MIBI was performed in 46 patients with coronary artery disease (CAD) and 15 normal subjects. The results were compared with exercise SPECT MPI. The results showed that the sensitivity and specificity of TAP SPECT to evaluate CAD were 86,96% and 93.33%. TAP SPECT MPI had a significant correlation with exercise SPECT MPI to detect ischemic segment of CAD (r = 0.95)

  4. Diagnosis of coronary artery disease using myocardial perfusion SPECT in patients with diabetes mellitus: analysis of risk factors

    International Nuclear Information System (INIS)

    Seo, Ji Hyoung; Kang, Seong Min; Bae, Jin Ho; Jeong, Shin Young; Lee, Sang Woo; Yoo, Jeong Soo; Ahn, Byeong Cheol; Lee, Jae Tae

    2006-01-01

    Diabetes mellitus is a critical disease with higher rates of cardiovascular morbidity and mortality due to myocardial ischemia and infarction. There is growing interest in how to determine high-risk patients who are candidates for screening testing. This study was performed to evaluate the incidence of coronary artery disease (CAD) in diabetic patients detected by Tc-99m MIBI myocardial perfusion SPECT (MPS) and to assess risk factors of CAD and cardiac hard events. 203 diabetic patients (64 male, mean age 64.1 ± 9.0 years) who underwent MPS were included between Jan 2000 and July 2004. Cardiac death and nonfatal myocardial infarction (MI) were considered as hard events, and coronary angioplasty and bypass surgery >60 days after testing were considered as soft events. The mean follow-up period was 36 ± 18 months. Patients underwent exercise (n=6) or adenosine stress (n=197) myocardial perfusion SPECT. Perfusion defects on MPS were detected in 28.6% (58/203) of the patients. There was no cardiac death but 11 hard events were observed. The annual cardiac hard event rate was 1.1%. In univariate analysis of clinical factors, typical anginal pain, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were significantly associated with the occurrence of hard events. Anginal pain, peripheral vascular disease, and resting ECG abnormality remained independent predictors of nonfatal MIs with multivariate analysis. Abnormal SPECT results were significantly associated with high prevalence of hard events but not independent predictors on uni- and multivariate analyses. patients who were male, had longer diabetes duration (especially over 20 years), peripheral vascular disease, peripheral polyneuropathy, or resting ECG abnormality had higher incidence of CAD. Among clinical factors in diabetic patients, typical angina, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were strong predictors of hard events

  5. Diagnosis of coronary artery disease using myocardial perfusion SPECT in patients with diabetes mellitus: analysis of risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ji Hyoung; Kang, Seong Min; Bae, Jin Ho; Jeong, Shin Young; Lee, Sang Woo; Yoo, Jeong Soo; Ahn, Byeong Cheol; Lee, Jae Tae [Kyungpook National University, Daegu, (Korea, Republic of)

    2006-06-15

    Diabetes mellitus is a critical disease with higher rates of cardiovascular morbidity and mortality due to myocardial ischemia and infarction. There is growing interest in how to determine high-risk patients who are candidates for screening testing. This study was performed to evaluate the incidence of coronary artery disease (CAD) in diabetic patients detected by Tc-99m MIBI myocardial perfusion SPECT (MPS) and to assess risk factors of CAD and cardiac hard events. 203 diabetic patients (64 male, mean age 64.1 {+-} 9.0 years) who underwent MPS were included between Jan 2000 and July 2004. Cardiac death and nonfatal myocardial infarction (MI) were considered as hard events, and coronary angioplasty and bypass surgery >60 days after testing were considered as soft events. The mean follow-up period was 36 {+-} 18 months. Patients underwent exercise (n=6) or adenosine stress (n=197) myocardial perfusion SPECT. Perfusion defects on MPS were detected in 28.6% (58/203) of the patients. There was no cardiac death but 11 hard events were observed. The annual cardiac hard event rate was 1.1%. In univariate analysis of clinical factors, typical anginal pain, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were significantly associated with the occurrence of hard events. Anginal pain, peripheral vascular disease, and resting ECG abnormality remained independent predictors of nonfatal MIs with multivariate analysis. Abnormal SPECT results were significantly associated with high prevalence of hard events but not independent predictors on uni- and multivariate analyses. patients who were male, had longer diabetes duration (especially over 20 years), peripheral vascular disease, peripheral polyneuropathy, or resting ECG abnormality had higher incidence of CAD. Among clinical factors in diabetic patients, typical angina, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were strong predictors of hard events.

  6. Gated spect myocardial perfusion scintigraphy for identifying septal perfusion artifacts in left bundle branch block

    International Nuclear Information System (INIS)

    Afzal, M.S.; Imran, M.B.; Akhtar, M.S.; Muhammand, K.; Nadeem, A.; Aslam, N.; Khurshid, S.J.; Farooq, U.I.; Sohaib, M.

    2006-01-01

    To determine the role of gated Single Photon Emission Computed Tomography (SPECT) for accurate assessment of myocardial perfusion scintigraphy (MPS) of patients with left bundle branch block (LBBB). MPS data of patients with LBBB was analyzed. Resting gated SPECT MPS was performed after an injection of 740 MBq 99mTc-MIBI in 10 normal and 25 subjects with LBBB (with low probability of coronary artery disease). Visual and quantitative analyses were done on non-gated (NG), end diastolic (ED), end systolic (ES) images. Calculations included septal to lateral wall ratio (SLR), myocardial thickening (MT=% increase in counts during systole) at end systolic phase and myocardial thickening at peak level (% peak MT). Septal hypoperfusion was noted in 19 (76%) patients on NG images and in only 1 (4%) patient on gated SPECT ED images. On NG images of LBBB group, SLR was lower than in controls (0.68 +- 0.07 vs. 0.87 +- 0.05, p<0.001). SLR of LBBB patients approached to that of control group in gated SPECT ED data (0.86 +- 0.06 vs 0.88 +- 0.06, p=ns). Myocardial thickening at ES for septum was markedly lower in LBBB group than in controls (21.83% +- 10.86 vs. 66.32% +- 20.15, p<0.001). (author)

  7. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging

    International Nuclear Information System (INIS)

    Pons, G.

    2011-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  8. Submaximal exercise thallium-201 SPECT for assessment of interventional therapy in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Stewart, R.E.; Kander, N.; Juni, J.E.; Ellis, S.G.; O'Neill, W.W.; Schork, M.A.; Topol, E.J.; Schwaiger, M.

    1991-01-01

    Submaximal thallium-201 stress testing has been shown to provide important diagnostic and prognostic information in patients with acute myocardial infarction. The purpose of this investigation was to evaluate the diagnostic value of early submaximal stress testing and thallium-201 single photon emission computed tomography (SPECT) after interventional therapy. Scintigraphic results from 56 patients with infarctions, who underwent acute thrombolytic therapy, angioplasty, or both, were compared with late (6 weeks) functional outcome as assessed by radionuclide ventriculography and with results of discharge coronary angiography. A linear correlation was found between the extent of thallium-201 SPECT perfusion defect and late ventricular function (r = 0.74, p less than 0.01). Forty-two percent of patients with large SPECT perfusion defects had normal left ventricular ejection fractions, suggesting an overestimation of infarct size by early imaging. Sensitivity and specificity of thallium-201 SPECT for detection of coronary artery stenosis in noninfarct territories was 57% and 46%, respectively, indicating limited diagnostic definition of extent of underlying coronary artery disease. Results of follow-up coronary angiography showed a significant relationship between the size of the initial perfusion defect and early restenosis or reocclusion of the infarct artery. Thus the extent of early thallium-201 perfusion defects correlates with late functional outcome but appears to overestimate the degree of injury. Submaximal thallium-201 stress testing allows only limited characterization of underlying coronary artery disease. Early assessment of infarct size may identify a patient population at high risk for reocclusion of the infarct artery

  9. Myocardial viability assessed by Tl-201 SPECT. Redistribution versus reinjection

    International Nuclear Information System (INIS)

    Chalela, William Azem; Pimentel, Flavio Ferrarini de Oliveira; Uchida, Augusto Hiroshi; Bottega, Augusto; Ramires, Jose Antonio Franchine; Izaki, Marisa; Moraes, Aguinaldo Pereira; Soares Junior, Jose; Giorgi, Maria C. Pinto; Moffa, Paulo Jorge; Bellotti, Giovanni; Giovanni Guido Cerri; Meneghetti, Jose Claudio

    1994-01-01

    The purpose of this study was to verify if a third series of images acquired by reinjection thallium-201, 24 h after conventional myocardial perfusion with the radioisotope, improves the identification of myocardial viability segments. The methods: we studied 30 patients, mean age 57.7 ±9.4 years, with old myocardial infarction using thallium (Tl)-201 SPECT, and we obtained three series of images (stress, redistribution after 4 h and reinjection after 24 h. Cardiac images were divided in 5 segments (apical, lateral, anterior, septal and inferior) and each one received a value by a score system according to the Tl-201 myocardial uptake (0=normal uptake; 1=mild hypoperfusion; 2=moderate hypoperfusion; 3=severe hypoperfusion or no myocardial uptake). We considered viable myocardium when the uptake of Tl-201 in the segment related to te myocardial infarction increases at least 1 point in two different axis of Tl-201 SPECT. The results: seven (23,3%) patients demonstrated increase of Tl-201 uptake only at reinjection images, showing a high efficacy of the method. Nine (30%) patients showed persistent hypoperfusion at all series of images suggesting only fibrosis in the are related to the infarction. Fourteen (46,7%) patients showed increase of Tl-201 concentration at redistribution images; among these patients, six showed improvement of myocardial uptake at reinjection. This condition was interpreted as regional chronic ischemic process: hibernating myocardium. The conclusion was that Tl-201 hypoperfusion at redistribution images without significant changes in relation to the stress images do not represent fibrosis at all. The reinjection technic was better than conventional redistribution in the detection of viable myocardium. This data allows a better therapeutic orientation. (author)

  10. Left ventricular functional parameters by gated SPECT myocardial perfusion imaging in a Latin American country.

    Science.gov (United States)

    Kapitan, Miguel; Beltran, Alvaro; Beretta, Mario; Mut, Fernando

    2018-04-01

    There is paucity of data on left ventricular (LV) functional parameters using gated SPECT myocardial perfusion imaging (MPI) from the Latin American region. This study provides detailed information in low-risk patients both at rest and during exercise. We studied 90 patients (50 men) with a very low likelihood of coronary artery disease. Gated-SPECT MPI was performed with Tc-99m MIBI using a 2-day protocol, with 16 frames/R-R cycle. The LV ejection fraction and volumes were not different between the rest and post-stress images. LVEF was 68 ± 7% post-stress and 70 ± 7% at rest in women, and 62 ± 7% and 63 ± 7%, respectively, in men (P = .19, .26). LV volumes were larger in men than women (P stress. Transient ischemic dilatation was similar, with upper limits of 1.20 and 1.19 in women and men, respectively (P = NS). These data could prove helpful for the interpretation of gated SPECT MPI data in Latin America using identical protocol as used in this study.

  11. Myocardial perfusion SPECT in diabetic patients for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Saeed, M.A.; Fatima, S.; Fatmi, S.; Kureshi, S.

    2003-01-01

    The aim of this study was to evaluate the efficacy of myocardial SPECT perfusion scan in the diagnosis of coronary artery disease in diabetic patients. A total number of thirty diabetic patients (21 males, 9 females) were included in the study. All the patients had strong risk-factors for coronary artery disease (strong family history, chronic smokers, hyperlipidemia, history of chest pain). All patients underwent coronary angiography and stress/rest myocardial perfusion SPECT scans with Tc-99m MIBI (two days protocol). Twenty two patients had significant coronary artery stenosis and 8 had normal coronary arteries. Myocardial perfusion scintigraphy (MPS) was positive in 19 subjects out of the 22 patients with significant stenosis (Sensitivity 86.4%) and negative (false negative) in only three. Out of 8 patients with normal angiography 7 had normal MPS (Specificity 87.5%) whereas only one patient revealed abnormality in the myocardial perfusion study. When compared with coronary angiography the positive predictive value and negative predictive value for Tc-99m MIBI myocardial perfusion scan was 86.4% and 87.5% respectively. In conclusion, Tc-99m MIBI myocardial perfusion scintigraphy is a useful screening modality for the detection of coronary artery disease in diabetic patients. (author)

  12. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 Inserm and Denis Diderot University, Paris (France); Koehl, Gregoire; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Poussier, Sylvain [INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U961, Nancy (France); Hopital de Brabois, CHU-Nancy, Medecine Nucleaire, Vandoeuvre-les-Nancy (France)

    2013-03-15

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving {sup 201}Tl (n = 120) or {sup 99m}Tc-sestamibi injected at low dose at stress ({sup 99m}Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ({sup 99m}Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, {sup 201}Tl 92 %, {sup 99m}Tc-Low 86 %, {sup 99m}Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the {sup 201}Tl or {sup 99m}Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 {+-} 101 kcounts) and dramatically enhanced with CZT SPECT (+279 {+-} 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  13. Reference Range of Functional Data of Gated Myocardial Perfusion SPECT by Quantitative Gated SPECT of Cedars-Sinai and 4D-MSPECT of Michigan University

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Kim, Moo Hyun; Kim, Young Dae [College of Medicine, Univ. of Donga, Pusan (Korea, Republic of)

    2003-07-01

    Various programs have been developed for gating of myocardial perfusion SPECT. Among the those program, the most popular program is the Quantitative Gated SPECT (QGS)? developed by Cedars-Sinai hospital and most recently released program is 4D-MSPECT? developed by university of Michigan. It is important to know the reference range of the functional data of gated myocardial perfusion SPECT because it is necessary to determine abnormality of individual patient and echocardiographic data is different from those of gated SPECT. Tc-99m MIBI gated myocardial perfusion SPECT image was reconstructed by dual head gamma camera (Siemens, BCAM, esoft) as routine procedure and analyzed using QGS? and 4D-MSPECT? program. All patients (M: F=9: 18, Age 69{+-}9 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded: previous angina or MI history, ECG change with Q wave or ST-T change, diabetes melitius, hypercholesterolemia, typical chest pain, hypertension and cardiomyopathy. Pre-test likelihood of all patients was low. (1) In stress gated SPECT by QGS?, EDV was 73{+-}25 ml, ESV 25{+-}14 ml, EF 67{+-}11 % and area of first frame of gating 106.4{+-}21cm{sup 2}. In rest gated SPECT, EDV was 76{+-}26 ml, ESV 27{+-}15 ml, EF 66{+-}12 and area of first frame of gating 108{+-}20cm{sup 2}. (2) In stress gated SPECT by 4D-MSPECT?, EDV was 76{+-}28 ml, ESV 23{+-}16 ml, EF 72{+-}11 %, mass 115{+-}24 g and ungated volume 42{+-}15 ml. In rest gated SPECT, EDV was 75{+-}27 ml, ESV 23{+-}12 ml, EF 71{+-}9%, mass 113{+-}25g and ungate dvolume 42{+-}15 ml, (3) s-EDV, s-EF, r-ESV and r-EF were significantly different between QGS? and 4D-MSPECT? (each p=0.016, p<0.001. p=0.003 and p=0.001). We determined the normal reference range of functional parameters by QGS? and 4D-MSPECT? program to diagnose individually the abnormality of patients. And the reference ranges have to adopted to be patients by each specific gating program.

  14. Detection of myocardial stunning with gated SPECT and its relationship with location, extension and severity of perfusion defects induced by exercise or pharmacologic stress

    International Nuclear Information System (INIS)

    Mut, F.; Beretta, M.; Vidal, I.; Rener, A.; Alonso, O.

    2002-01-01

    Aim: To investigate the relationship between transient ventricular dysfunction detected by gated SPECT with the location, extension and severity of ischemic areas in patients with reversible perfusion defects. Material and Methods: We retrospectively studied 83 patients (61±11 yrs., 61 men, 27 with previous MI) submitted for coronary artery disease (CAD) evaluation with 99mTc-MIBI gated SPECT using a 2-day protocol whose perfusion imaging pattern had been reported positive for myocardial ischemia. Stress test was exercise in 54 cases, dipyridamole in 28 and dobutamine in 1. Previous work from our group demonstrated up to 12% change in LVEF from rest to post-stress in a population with low likelihood of CAD and a normal perfusion pattern. Thus, according to % variation of left ventricular ejection fraction (LVEF) from rest to post-stress we further divided the population into 2 subgroups, (A) with less than 12% change in LVEF (n=56) and (B) with more than 12% negative variation (n=27). For evaluation of perfusion, a simplified 7-segment division of the myocardium was used and a combined ischemic score was obtained by multiplying the number of segments with reversible defects by the 1-4 assigned severity score. Results: There was no significant difference between the two groups regarding age, gender, stress result (clinical or ECG), number of fixed perfusion defects or rest LVEF. Dipyridamole test was more frequent among patients of group B. Post-stress LVEF was 49±14% for group A and 41±15% for group B, p=0.0125. Combined ischemic score was 6.82±6.5 vs. 11.96±12 respectively, p=0.014. In patients of group A, defects corresponding to the right coronary territory were more frequent, while the left descending artery territory was more commonly affected in group B patients, however this was not statistically significant. Left circumflex territory was equally affected in both groups. Conclusion: Transient ventricular dysfunction after a stress test can be

  15. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  16. Creation and characterization of Japanese standards for myocardial perfusion SPECT. Database from the Japanese Society of Nuclear Medicine Working Group

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Kumita, Shinichiro; Ishida, Yoshio

    2007-01-01

    Standards for myocardial single-photon emission computed tomography (SPECT) adapted for a Japanese population were not available. The purpose of this study was to create standard files approved by the Japanese Society of Nuclear Medicine and to make known the characteristics of the myocardial perfusion pattern of this population. With the collaboration of nine hospitals, a total of 326 sets of exercise-rest myocardial perfusion images were accumulated from subjects with a low likelihood of cardiac diseases. The normal database included a 99m Tc-methoxyisobutylisonitrile (MIBI)/tetrofosmin myocardial perfusion study with 360 deg (n=80) and 180 deg (n=56) rotations, 201 Tl study with 360 deg (n=115) and 180 deg rotations (n=54) and a dual-isotope study with 360 deg rotation (n=27). The projection images were transferred by digital imaging and communications in medicine (DICOM) format and reconstructed and analyzed with polar maps. The projection data from multiple centers were successfully transferred to a common format for SPECT reconstruction. When the average values were analyzed using a 17-segment model, myocardial counts in the septal segment differed significantly between 180 deg and 360 deg rotation acquisitions. Regional differences were observed between men and women in the inferior and anterior regions. A tracer difference between 99m Tc and 201 Tl was also observed in some segments. The attenuation patterns differed significantly between subjects from the United States and those from Japan. Myocardial perfusion data that were specific for the Japanese population were generated. The normal database can serve a standard for nuclear cardiology work conducted in Japan. (author)

  17. The Effect and Side Effect of Dipyridamole in Myocardial SPECT

    International Nuclear Information System (INIS)

    Yang, Hyung In; Lee, Dong Soo; Yeo, Jeong Suk; Bae, Sang Kyun; Choi, Chang Woon; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon

    1993-01-01

    Dipyridamole is an agent that may be used to noninvasively evaluate coronary artery disease. The effect of dipyridamole infusion its generally related to its induced peripheral vasodilatory effect. In normal person, heart rate is generally increased slightly while blood pressure decrease, but the achieved double product and related myocardial oxygen consumption have no significant change. The purpose of this study is to examine the effect and side effect of dipyridamole, and to compare different response to dipyridamole among the patients. We evaluated 847 patients who underwent dipyridamole stress myocardial SPECT. 93.6% of them had induced hypotension 0.9% showed no change of blood pressure, 5.5% had increased blood pressure 8.3% had no change of pulse rate more than 10% of basal pulse rate. Among diabetes, 16.9% was not change of pulse rate, 6.7% in non-diabetes. There was no significant correlation between age and rate pressure product rest(RPPr), in patients without perfusion defects on SPECT(y=7.1x+48.4r=0.13 p>0.01). As increasing age, RPPs/RPPr was declined(y=-11.6x+68.9 r=0.17 p<0.01), similar results were obtained in patients with perfusion defect. The size of perfusion defect on myocardial SPECT have no correlation between RPPr and RPPs/RPPr. The side effects of dipyridamole included chest pain and chest tightness, headache, abdominal pain, dizziness, nausea, and dyspnea. As increasing age, dipyridamole-induced cardiac work at rest was increased, cardiac response to dipyridamole was decreased.

  18. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with {sup 13}N-Ammonia PET myocardial blood flow quantitation

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, Missouri (United States); Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng [Taipei Veterans General Hospital, Department of Nuclear Medicine, Taipei (China); Chen, Lung-Ching [Shin Kong Wu-Ho Su Memorial Hospital, Division of Cardiology, Taipei (China); Chen, Yen-Kung [Shin Kong Wu-Ho Su Memorial Hospital, Department of Nuclear Medicine, Taipei (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Wu, Tao-Cheng [National Yang-Ming University, Cardiovascular Research Center, Taipei (China)

    2017-01-15

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of {sup 99m}Tc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with {sup 13}N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R{sup 2}: MBF = 0.92, MFR = 0.78; regional R{sup 2}: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected

  19. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with "1"3N-Ammonia PET myocardial blood flow quantitation

    International Nuclear Information System (INIS)

    Hsu, Bailing; Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng; Chen, Lung-Ching; Chen, Yen-Kung; Hung, Guang-Uei; Wu, Tao-Cheng

    2017-01-01

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of "9"9"mTc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with "1"3N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R"2: MBF = 0.92, MFR = 0.78; regional R"2: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected. (orig.)

  20. Influence of the prevalence of coronary artery disease in patients with normal myocardial perfusion SPECT imaging. Cooperative study in South America

    International Nuclear Information System (INIS)

    Balestrini, V.R.; Arja, V.J.; Sandrin, A.L.; Sala, J.P.; Joekes, S.; Bier, G.; Precoma, D.; Yamada, A.

    2002-01-01

    An important feature of myocardial perfusion imaging is the ability to predict prognosis and identify high- and low-risk patients for coronary events. According to Bayes' theorem, the significance of test's results, relates not only the sensitivity and specificity of a test but also the prevalence of disease in the population under study. Aim: evaluate the relationship between pretest likelihood (PTL) and coronary events (CE) in patients with normal myocardial perfusion SPECT imaging during a long period of time. Material and Methods: The population included 709 patients (411 men and 298 women, mean age 58 years old) who underwent stress/rest myocardial perfusion SPECT imaging at nuclear cardiology laboratories in Argentina and Brazil, with scintigraphic images interpreted as normal. Analyzed variables: clinical, EKG and stress test. Perfusion agents: Tc-99m-tetrofosmin: 36.5%, Tc99m-sestamibi 5.8% and Tl-201 57.7%. Mean follow up: 919 days. CE: soft (unstable angina and need for revascularization) and hard (AMI and cardiac death). Results: Stress test: exercise stress test 72.2%, dipyridamole 25%, adenosine 1.7%, dobutamine 1.1%. PTL [ 9' (M/F): 59/11% (p 78%] 31 vs. 50%. Conclusions: 1) There was a relationship between PTL, events rate and time to event. 2) We found a low hard events rate (0.85%). 3) The results in this group of patients with normal myocardial perfusion SPECT imaging may suggest a guarantee period of low risk of coronary events between 2-3 years. 4) In spite of there is a low event rate in total population with normal myocardial perfusion imaging, patients with highest prevalence of coronary artery disease have more statistical probabilities of coronary events and therefore they have to be watched closely

  1. Peritoneal fluid causing inferior attenuation on SPECT thallium-201 myocardial imaging in women

    International Nuclear Information System (INIS)

    Rab, S.T.; Alazraki, N.P.; Guertler-Krawczynska, E.

    1988-01-01

    On SPECT thallium images, myocardial left ventricular (LV) anterior wall attenuation due to breast tissue is common in women. In contrast, in men, inferior wall counts are normally decreased compared to anterior counts. The purpose of this report is to describe cases of inferior wall attenuation of counts in women caused by peritoneal fluid, not myocardial disease. Twelve consecutive SPECT thallium myocardial studies performed in women on peritoneal dialysis, being evaluated for kidney transplant, were included in this study. For all studies, 3.5 mCi 201Tl were injected intravenously. Thirty-two images were acquired over 180 degrees (45 degrees RAO progressing to 45 degrees LPO) at 40 sec per stop. SPECT images were reviewed in short axis, horizontal long and vertical long axes. Data were also displayed in bullseye format with quantitative comparison to gender-matched normal files. Ten of 12 female patients studied had inferior wall defects on images, confirmed by bullseye display. All patients had approximately 2 liters of peritoneal fluid. Review of planar rotational views showed diaphragm elevation and fluid margin attenuations affecting left ventricular inferior wall. Thus, peritoneal fluid is a cause of inferior attenuation on 201Tl cardiac imaging

  2. MRS algorithm: a new method for searching myocardial region in SPECT myocardial perfusion images.

    Science.gov (United States)

    He, Yuan-Lie; Tian, Lian-Fang; Chen, Ping; Li, Bin; Mao, Zhong-Yuan

    2005-10-01

    First, the necessity of automatically segmenting myocardium from myocardial SPECT image is discussed in Section 1. To eliminate the influence of the background, the optimal threshold segmentation method modified for the MRS algorithm is explained in Section 2. Then, the image erosion structure is applied to identify the myocardium region and the liver region. The contour tracing method is introduced to extract the myocardial contour. To locate the centriod of the myocardium, the myocardial centriod searching method is developed. The protocol of the MRS algorithm is summarized in Section 6. The performance of the MRS algorithm is investigated and the conclusion is drawn in Section 7. Finally, the importance of the MRS algorithm and the improvement of the MRS algorithm are discussed.

  3. SPECT myocardial perfusion imaging. Long-term prognostic value in diabetic patients with and without coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Koehli, M. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Monbaron, D.; Gaillard, R.C.; Ruiz, J. [Dept. of Endocrinology, Diabetology and Metabolism, Univ. Hospital Lausanne (Switzerland); Prior, J.O.; Bischof Delaloye, A. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Calcagni, M.L. [Dept. of Nuclear Medicine, Univ. Hospital Lausanne (Switzerland); Dept. of Cardiology, Univ. Hospital Lausanne (Switzerland); Fivaz-Arbane, M.; Stauffer, J.C. [Inst. of Nuclear Medicine, Univ. Cattolica del Sacro Cuore, Roma (Italy)

    2006-07-01

    Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Patients, methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curve and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 {+-} 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p < 0.0001), followed by history of CAD (Hazard Ratio (HR) = 15.9; p = 0.0001), diabetic retinopathy (HR = 10.0; p = 0.001) and inability to exercise (HR = 7.7; p = 0.02). Patients with normal MPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. Conclusion: Diabetic patients with normal MPI had on excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a > 5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. (orig.)

  4. Limited diagnostic accuracy of gated myocardial perfusion SPECT for wall motion analysis in patients with asymmetric septal hypertrophy

    International Nuclear Information System (INIS)

    Seo, J.H.; Ahn, B.C.; Bae, J.H.; Jeong, S.Y.; Lee, J.; Lee, K.B.

    2004-01-01

    Objective: Although gated SPECT(G-SPECT) using Tc-99m MIBI is well-known diagnostic modality in the evaluation of myocardial perfusion and wall motion analysis, there were limited reports for subjects with asymmetric septal hypertrophy (ASH). This study was performed to evaluate the clinical usefulness of G-SPECT for assessments of myocardial perfusion and wall motion analysis in patients with ASH on 2D-echocardiography(Echo). Methods: Thirty patients (male 18, 59 12 years) with ASH on Echo (septal wall thickness 13 mm and 1.3 times as thick as that of posterior wall) underwent Tc-99m MIBI G-SPECT. Two studies were performed within one month. No patient had experienced any significant cardiac event, nor had changed medical and surgical therapy during the studies. Functional parameters of the left ventricle were acquired with QGS software(AutoQUANTTM). Three experts performed visual interpretation for the presence of septal thickening and perfusion abnormalities on G-SPECT and two experienced cardiologists measured dimension, thickness and wall motion of the left ventricle on Echo. Results: Mean septum thickness measured by Echo was 1.90 0.50 cm, and the septum/posterior wall thickness ratio was 1.85 0.51. On visual SPECT analysis, 14 patients (46.7%) were interpreted as with thickened septum and 17 patients (57%) as with abnormal perfusion. All 3 patients who underwent coronary angiography showed significant luminal stenosis and also had perfusion abnormalities on SPECT. On Echo, only one patient showed septal hypokinesia, who showed anteroseptal infarction on SPECT, and the others showed normal septal wall motion. But 13 patients (54%) among 24 patients showed septal hypokinesia on G-SPECT. Patients with thickened septum on SPECT had thicker septum (2.3 vs 1.6 cm) and higher septum/posterior wall thickness ratio (2.2 vs 1.6) on Echo, compared with patients without septal thickening on SPECT. Conclusions: Although G-SPECT could proffer diagnostic accuracy for

  5. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    Science.gov (United States)

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p IQ-SPECT with and without SCAC was also good (r = 0.907 and p IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating characteristic analysis were 0.77, 0.80, and 0.86 for conventional SPECT, IQ-SPECT without SCAC, and IQ-SPECT with SCAC, respectively (p = n.s. for each comparison). When appropriate NDBs were used, the diagnostic performance of 201 Tl IQ-SPECT

  6. Bull's-eye map of myocardial perfusion MR imaging. Comparison with SPECT

    International Nuclear Information System (INIS)

    Nomura, Yukihiro; Nanjo, Shuji; Yamazaki, Junichi; Yoshikawa, Kohki; Inoue, Yusuke

    2003-01-01

    When diagnosing heart disease, chest roentgenograms, ultrasonography, single-photon emission computed tomography (SPECT), and coronary arteriography are usually performed. Magnetic resonance (MR) imaging is not widely used for evaluating heart disease. Recent technological progress has allowed high quality images of the heart to be reliably obtained. A routine MR study taking about 30-40 minutes can provide a large amount of diagnostic information, such as cardiac structure, function, perfusion, and myocardial viability. The analysis software that can offer Bull's-eye maps from myocardial perfusion images has recently become commercially available. In this study, the characteristics of Bull's-eye mapping of MR imaging is compared with that of Bull's-eye mapping of SPECT using the same heart phantom. The difference in the image quality of the Bull's-eye maps was evaluated among the receiver coils of MR imaging. On Bull's-eye maps from both MR imaging and SPECT, decreased signal intensity was noted in the posterolateral wall. The degree of decrease in the signal of the MR imaging was more prominent than of SPECT. The decrease was severe for the general-purpose receive-only flexible (GPFLEX) coil, moderate for the cardiac and TORSO coil, and slight for the body coil. In the selection of a coil, it is necessary to take into consideration the trade-off between the distribution of signal intensity and the signal-to-noise ratio (SNR). (author)

  7. Clinical application of heart rate-synchronized myocardial SPECT with {sup 99m}Tc-labeled imaging agents for myocardial blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Fukuchi, Kazuki; Tsujimura, Eiichiro; Hasegawa, Shinji; Ito, Yasushi; Hashimoto, Katsuji; Matsuda, Shinichi; Yutani, Kenji [Osaka Univ., Suita (Japan). Biomedical Research Center

    1996-11-01

    Application of gated SPECT to assess multiple heart functions simultaneously in authors` facility was reported. The myocardial SPECT at rest was performed 1 hr after intravenous administration of 740 MBq of {sup 99m}Tc-sestamibi with Toshiba 3-detector type gamma camera GCA9300/HG. R wave monitored by ECG was used as a trigger to record images of 360deg direction (90 sec/6deg direction, 20 directions x 3). Data were processed by Toshiba GMS-5500A or Hitachi-Medico RW3000. Percent CI (count increase at a myocardial region) was calculated by =(ES-ED)=/ED x 100, where ES and ED were computed by circumferential profile analysis of reconstruction images at the end-systole and end-diastole stages, respectively. Left ventricular ejection fraction was calculated from %AC (area change between areas of left ventricle at end-systolic and -diasystolic stages). Ventricular wall-motion was assessed by bullet display of the gated SPECT images. The present procedure is expected to be widely used as a routine test of the myocardial functions and is beneficial from a viewpoint of cost/performance. (K.H.)

  8. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  9. Clinical significance of exercise induced ST segment depression after successful percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Aoki, Toshikazu; Konishi, Tokuji; Futagami, Yasuo

    1989-01-01

    To evaluate the clinical significance of ST segment depression during repeated Treadmill exercise after successful PTCA, Thallium-201 SPECT was performed. The Thallium-201 SPECT was performed before, one week after and 3-6 months after PTCA. All thirty-five patients had one vessel disease and positive Thallium-201 exercise test. During follow-up period for 3-6 months, 11 of 35 patients had persistent ST segment depression. Restenosis of dilated coronary lesion was demonstrated in 6 of 11 patients. In another 3 of 35 patients, exercise induced ST segment depression was disappered during follow-up Treadmill exercise. In 14 patients with persistent or transient ST segment depression after PTCA, Thallium-201 SPECT demonstrated transient ischemia in 5 of 6 patients with restenosis. In other 8 patients without restenosis, SPECT images did not demonstrate myocardial ischemia and coronary arteriographic findings could not verify side branch stenosis or intimal dissection which might cause myocardial ischemia. The etiology of ST segment depression after successful PTCA in one vessel disease is not produced by exercise induced myocardial ischemia but still unknown mechanisms may be present. (author)

  10. Cardiac functional mapping for thallium-201 myocardial perfusion, washout, wall motion and phase using single-photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taniguchi, Mitsuru; Taki, Junichi; Tonami, Norihisa; Hisada, Kinichi; Hirano, Takako; Wani, Hidenobu.

    1986-01-01

    A method for three-dimensional functional mapping of Tl-201 myocardial uptake, washout, wall motion and phase was developed using SPECT. Each parameter was mapped using polar display in the same format. Normal values were determined in Tl-201 exercise study in 16 patients. Myocardial counts were lower in the septum and inferior wall and the difference of counts between anterior and inferior walls were greater in man compared with the perfusion pattern in woman. Washout was slower at septum and inferior wall in man, and slightly slower at inferior wall in woman. In gated blood-pool tomography, length-based and count-based Fourier analyses were applied to calculate the parameters of contraction and phase. The results of both Fourier analyses generally agreed; however, the area of abnormality was slightly different. Phase maps were useful for the assessment of asynergy as well as in patients with conduction disorders. These cardiac functional maps using SPECT were considered to be effective for the understanding of three-dimensional informations of cardiac function. (author)

  11. Comparison of myocardial function between post-menopausal and pre-menopausal women: evaluation by gated myocardial SPECT

    International Nuclear Information System (INIS)

    Hwang, K. H.; Choa, Won Sick; Yoon, Min Ki

    2005-01-01

    In addition to inhibiting coronary atherosclerosis, estrogen is expected to have protective effects on cardiac myocytes. We investigated the difference in myocardial functional parameters evaluated by gated myocardial SPECT after adenosine-stress between post-menopausal and pre-menopausal healthy women. This study included 22 healthy post-menopausal women (mean age: 53.0 yr) and 20 pre-menopausal women (mean age: 43.0 yr) who performed Tc-99m tetrofosmin gated myocardial SPECT after adenosine-stress. Measured hemodynamic parameters, EDV, ESV, stroke volume, EF, cardiac output and cardiac index were compared between the two groups. For comparison, similar-aged two male groups with matched numbers were also studied. There was no significant difference in hemodynamic parameters. EDV, ESV, stroke volume, EF, or cardiac output between the post-menopausal and pre-menopausal women. However, post-menopausal women have a smaller cardiac index (mean: 1.95 L/min/m2 vs 2.20 L/min/m2; p=0.045) and adenosine-induced HR increase (mean : 80.5/min vs 89.7/min ; p=0.03), compared to the pre-menopausal women. On the contrary, the two male groups of the same age range and numbers with the women groups showed no significant difference in any myocardial parameters. These results suggest that menopause may be correlated with reduced increase in cardiac index and HR increase after adenosine-stress

  12. Comparison of myocardial function between post-menopausal and pre-menopausal women: evaluation by gated myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, K. H.; Choa, Won Sick; Yoon, Min Ki [Gachon Medical School, Gil Hospital, Incheon (Korea, Republic of)

    2005-07-01

    In addition to inhibiting coronary atherosclerosis, estrogen is expected to have protective effects on cardiac myocytes. We investigated the difference in myocardial functional parameters evaluated by gated myocardial SPECT after adenosine-stress between post-menopausal and pre-menopausal healthy women. This study included 22 healthy post-menopausal women (mean age: 53.0 yr) and 20 pre-menopausal women (mean age: 43.0 yr) who performed Tc-99m tetrofosmin gated myocardial SPECT after adenosine-stress. Measured hemodynamic parameters, EDV, ESV, stroke volume, EF, cardiac output and cardiac index were compared between the two groups. For comparison, similar-aged two male groups with matched numbers were also studied. There was no significant difference in hemodynamic parameters. EDV, ESV, stroke volume, EF, or cardiac output between the post-menopausal and pre-menopausal women. However, post-menopausal women have a smaller cardiac index (mean: 1.95 L/min/m2 vs 2.20 L/min/m2; p=0.045) and adenosine-induced HR increase (mean : 80.5/min vs 89.7/min ; p=0.03), compared to the pre-menopausal women. On the contrary, the two male groups of the same age range and numbers with the women groups showed no significant difference in any myocardial parameters. These results suggest that menopause may be correlated with reduced increase in cardiac index and HR increase after adenosine-stress.

  13. Time course evaluation of myocardial perfusion after reperfusion therapy by 99mTc-tetrofosmin SPECT in patients with acute myocardial infarction.

    Science.gov (United States)

    Tanaka, R; Nakamura, T

    2001-09-01

    Myocardial perfusion imaging with 99mTc-labeled agents immediately after reperfusion therapy can underestimate myocardial salvage. It is also conceivable that delayed imaging is useful for assessing the risk area. However, to our knowledge, very few studies have sequentially evaluated these image changes. We conducted 99mTc-tetrofosmin (TF) and 123I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) SPECT before and after reperfusion to treat acute myocardial infarction and quantified changes in TF myocardial accumulation and reverse redistribution. Seventeen patients with a first myocardial infarction underwent successful reperfusion. We examined SPECT images obtained at the onset (preimage), those acquired 30 min (early image) and 6 h (delayed image) after TF injection, and images acquired 1, 4, 7, and 20 d after reperfusion (post-1-d, post-4-d, post-7-d, and post-20-d image, respectively). We also examined BMIPP SPECT images after 7 +/- 1.8 d (BMIPP image). Polar maps were divided into 48 segments to calculate percentage uptake, and time course changes in segment numbers below 60% were observed as abnormal area. Moreover, cardiac function was analyzed by gated TF SPECT on 1 and 20 d after reperfusion. In reference to the abnormal area on the early images, the post-1-d image was significantly improved compared with the preimage (P < 0.01) as was the post-7-d image compared with the post-1-d and post-4-d images (P < 0.05, respectively). However, post-20-d and post-7-d images did not significantly differ. Therefore, the improvement in myocardial accumulation reached a plateau 7 d after reperfusion. On the other hand, the abnormal area on the delayed images was significantly greater (P < 0.01) compared with that on the early images from 4 to 20 d after reperfusion, as the value was essentially constant. The correlations of the abnormal area between the preimage and the post-7-d delayed image, the preimage and the BMIPP image, and the post-7-d delayed image and the

  14. 'Motion frozen' quantification and display of myocardial perfusion gated SPECT

    International Nuclear Information System (INIS)

    Slomka, P.J.; Hurwitz, G.A.; Baddredine, M.; Baranowski, J.; Aladl, U.E.

    2002-01-01

    Aim: Gated SPECT imaging incorporates both functional and perfusion information of the left ventricle (LV). However perfusion data is confounded by the effect of ventricular motion. Most existing quantification paradigms simply add all gated frames and then proceed to extract the perfusion information from static images, discarding the effects of cardiac motion. In an attempt to improve the reliability and accuracy of cardiac SPECT quantification we propose to eliminate the LV motion prior to the perfusion quantification via automated image warping algorithm. Methods: A pilot series of 14 male and 11 female gated stress SPECT images acquired with 8 time bins have been co-registered to the coordinates of the 3D normal templates. Subsequently the LV endo and epi-cardial 3D points (300-500) were identified on end-systolic (ES) and end-diastolic (ED) frames, defining the ES-ED motion vectors. The nonlinear image warping algorithm (thin-plate-spline) was then applied to warp end-systolic frame was onto the end-diastolic frames using the corresponding ES-ED motion vectors. The remaining 6 intermediate frames were also transformed to the ED coordinates using fractions of the motion vectors. Such warped images were then summed to provide the LV perfusion image in the ED phase but with counts from the full cycle. Results: The identification of the ED/ES corresponding points was successful in all cases. The corrected displacement between ED and ES images was up to 25 mm. The summed images had the appearance of the ED frames but have been much less noisy since all the counts have been used. The spatial resolution of such images appeared higher than that of summed gated images, especially in the female scans. These 'motion frozen' images could be displayed and quantified as regular non-gated tomograms including polar map paradigm. Conclusions: This image processing technique may improve the effective image resolution of summed gated myocardial perfusion images used for

  15. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV F on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author)

  16. Evaluation of cardiomyopathy in Duchenne muscular dystrophy by Tl-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Jinnouchi, Seishi; Asai, Junko; Inoue, Kenjirou; Hoshi, Hiroaki; Watanabe, Katsushi.

    1985-01-01

    Clinical evaluation of Tl-201 myocardial SPECT in patients with cardiomyopathy of Duchenne type progressive muscular dystrophy (DMD) was reported. Cases subjected to study were 14 DMD and 8 normal. Using a rotating gamma camera system (ZLC7500 and Scintipac 70A), SPECT data were collected for 16 minutes (32 angles x 30 sec/angle, 180 0 ). The hypoperfusion areas of the left ventricular muscle were observed in 10 patients (71 %), which was in posterior wall (71 %), inferior wall (57 %), lateral and anterior wall (43 %) in the order of frequency. The hypoperfusion area became wider with age and stage, exept for some patients. It was suggested that myocardial degeneration in DMD started in posterior wall and then spread in other areas. For the purpose of quantitative evaluation of myocardial damage, Tl-201 myocardial uptake ratio (MUR) and left ventricular muscle volume (LVMV) were calculated using the results obtained by phantom studies. MUR and LVMV were higher in DMD than those of normal individuals (3.6 +- 1.0 %: 2.7 +- 0.3 %, p < 0.05, 190.2 +- 67.5 ml: 157.8 +- 21.5 ml, n.s., respectively). (author)

  17. Utility of the combination of DAT SPECT and MIBG myocardial scintigraphy in differentiating dementia with Lewy bodies from Alzheimer's disease

    International Nuclear Information System (INIS)

    Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Namioka, Nayuta; Hatanaka, Hirokuni; Hirose, Daisuke; Fukasawa, Raita; Umahara, Takahiko; Sakurai, Hirohumi; Hanyu, Haruo

    2016-01-01

    123 I-2β-Carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl) nortropane ( 123 I-FP-CIT) dopamine transporter single photon emission computed tomography (DAT SPECT) and 123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy can be used to assist in the diagnosis of patients with dementia with Lewy bodies (DLB). We compared the diagnostic value of these two methods in differentiating DLB from Alzheimer's disease (AD). Furthermore, we evaluated whether a combination of DAT SPECT and MIBG myocardial scintigraphy would provide a more useful means of differentiating between DLB and AD. Patients with AD (n = 57) and patients with DLB (n = 76) who underwent both DAT SPECT and MIBG myocardial scintigraphy were enrolled. The sensitivity, specificity, and accuracy of both methods as well as their combination for differentiating DLB from AD were calculated. Moreover, we examined whether symptoms of the patients with DLB were associated with the patterns of the abnormalities displayed on DAT SPECT and MIBG myocardial scintigraphy. The sensitivity and specificity of differentiating DLB from AD were 72.4 and 94.4 % by the heart to mediastinum ratio of MIBG uptake, 88.2 and 88.9 % by the specific binding ratio on DAT SPECT, and 96.1 and 90.7 % by their combination, respectively. The combined use of DAT SPECT and MIBG myocardial scintigraphy enabled more accurate differentiation between DLB and AD compared with either DAT SPECT or MIBG myocardial scintigraphy alone. There was a significantly higher frequency of parkinsonism in the abnormal DAT SPECT group than the normal DAT SPECT group. On the other hand, there was a higher frequency of the appearance of rapid eye movement (REM) sleep behavior disorder in the abnormal MIBG uptake group than the normal MIBG uptake group. These results suggested that using a combination of these scintigraphic methods is a useful and practical approach to differentiate DLB from AD. (orig.)

  18. Usefulness of exercise echocardiography in ischemic heart disease. Comparison with exercise cardiac scintigraphy

    International Nuclear Information System (INIS)

    Tashiro, Hideki; Koyanagi, Samon; Narabayashi, Hideki; Inou, Tetsuji; Takeshita, Akira

    1999-01-01

    Exercise echocardiography and exercise thallium-201 ( 201 Tl) single photon emission computed tomography (SPECT) were performed in 152 patients with suspected coronary artery disease, including 61 patients with old myocardial infarction. All patients underwent coronary arteriography, and coronary artery disease was defined as ≥75% diameter stenosis. Digital two-dimensional echocardiography was performed before and after the treadmill exercise test, and wall motion abnormality was evaluated using quad-screen. Sensitivity and specificity for the diagnosis of coronary artery disease were similar for the 2 exercise tests (77% and 80% for echocardiography and 75%, and 83% for SPECT, respectively). Diagnoses for one-vessel disease, 2-vessel disease and 3-vessel disease were similar for echocardiography (79%, 72% and 77%, respectively) and SPECT (74%, 75% and 77%, respectively). Sensitivity for the diagnosis of ischemia at the area remote from infarct area was low for both exercise echocardiography and exercise SPECT (45% and 48%, respectively). Exercise echocardiography has comparable diagnostic value to SPECT for the detection of coronary artery disease. However, both exercise tests have limitations for the diagnosis of ischemia at the area remote from infarct area. (author)

  19. Calculation of left ventricular volume and ejection fraction from ECG-gated myocardial SPECT. Automatic detection of endocardial borders by threshold method

    International Nuclear Information System (INIS)

    Fukushi, Shoji; Teraoka, Satomi.

    1997-01-01

    A new method which calculate end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) of the left ventricle from myocardial short axis images of ECG-gated SPECT using 99m Tc myocardial perfusion tracer has been designed. Eight frames per cardiac cycle ECG-gated 180 degrees SPECT was performed. Threshold method was used to detect myocardial borders automatically. The optimal threshold was 45% by myocardial SPECT phantom. To determine if EDV, ESV and LVEF can also be calculated by this method, 12 patients were correlated ventriculography (LVG) for 10 days each. The correlation coefficient with LVG was 0.918 (EDV), 0.935 (ESV) and 0.900 (LVEF). This method is excellent at objectivity and reproductivity because of the automatic detection of myocardial borders. It also provides useful information on heart function in addition to myocardial perfusion. (author)

  20. Prognostic value of myocardial perfusion SPECT versus exercise electrocardiography in patients with ST-segment depression on resting electrocardiography.

    Science.gov (United States)

    De Lorenzo, Andrea; Hachamovitch, Rory; Kang, Xingping; Gransar, Heidi; Sciammarella, Maria G; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Germano, Guido; Berman, Daniel S

    2005-01-01

    The value of exercise-induced ST-segment depression for the prognostic evaluation of patients with 1 mm of ST depression or greater on the resting electrocardiogram is controversial. Patients who underwent exercise myocardial perfusion single photon emission computed tomography (MPS) and had resting ST depression of 1 mm or greater with a nondiagnostic exercise electrocardiographic response (n = 1122) were followed up for 3.4 +/- 2.3 years. Those with paced rhythm, pre-excitation, left bundle branch block, or myocardial revascularization within the first 60 days after MPS were excluded. Additional exercise-induced ST-segment depression was considered significant if > or = 2 mm MPS was scored semiquantitatively by use of a 20-segment model of the left ventricle; the percentage of myocardium involved with stress defects (% myo) was derived by normalizing to the maximal possible score of 80. Hard events were defined as nonfatal myocardial infarction or cardiac death. A Cox analysis was used to determine independent predictors of hard events among clinical, exercise, and nuclear variables. Hard event rates increased as a function of % myo for either patients with exercise-induced ST depression (1.4%/y for normal MPS vs 4.1%/y for % myo >10%, P 10%, P = .0001). Age, diabetes mellitus, shortness of breath as the presenting symptom, and % myo were independent predictors of hard events. Exercise-induced ST depression was predictive of hard events only when it was 3 mm or greater. The presence and extent of perfusion defects, reflected in the % myo, had incremental prognostic value over clinical variables and also over all degrees of exercise-induced ST depression. Although MPS effectively risk-stratifies patients with resting ST depression of 1 mm or greater, the prognostic value of exercise-induced ST depression is limited in these patients, with a small added risk when severe (> or = 3 mm).

  1. Relationship Between Coronary Contrast-Flow Quantitative Flow Ratio and Myocardial Ischemia Assessed by SPECT MPI.

    Science.gov (United States)

    Smit, Jeff M; Koning, Gerhard; van Rosendael, Alexander R; Dibbets-Schneider, Petra; Mertens, Bart J; Jukema, J Wouter; Delgado, Victoria; Reiber, Johan H C; Bax, Jeroen J; Scholte, Arthur J

    2017-10-01

    A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called "contrast-flow quantitative flow ratio (cQFR)". Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters.

  2. Myocardial viability assessment with dynamic low-dose iodine-123-iodophenylpentadecanoic acid metabolic imaging: comparison with myocardial biopsy and reinjection SPECT thallium after myocardial infarction.

    Science.gov (United States)

    Murray, G L; Schad, N C; Magill, H L; Vander Zwaag, R

    1994-04-01

    Aggressive cardiac revascularization requires recognition of stunned and hibernating myocardium, and cost considerations may well govern the technique used. Dynamic low-dose (1 mCi) [123I]iodophenylpentadecanoic acid (IPPA) metabolic imaging is a potential alternative to PET using either 18FDG or 15O-water. Resting IPPA images were obtained from patients with severe ischemic cardiomyopathy, and transmural myocardial biopsies were obtained during coronary bypass surgery to confirm viability. Thirty-nine of 43 (91%) biopsies confirmed the results of the IPPA images with a sensitivity for viability of 33/36 (92%) and a specificity of 6/7 (86%). Postoperatively, wall motion improved in 80% of IPPA-viable, dysfunctional segments. Furthermore, when compared to reinjection thallium (SPECT-TI) scans after myocardial infarction, IPPA-SPECT-TI concordance occurred in 27/35 (77%) (K = 0.536, p = 0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-TI, 26/35 (74%) versus 18/35 (51%) (p = 0.047). Metabolic IPPA cardiac viability imaging is a safe, inexpensive technique that may be a useful alternative to PET.

  3. Myocardial multilayer strain does not provide additional value for detection of myocardial viability assessed by SPECT imaging over and beyond standard strain.

    Science.gov (United States)

    Orloff, Elisabeth; Fournier, Pauline; Bouisset, Frédéric; Moine, Thomas; Cournot, Maxime; Elbaz, Meyer; Carrié, Didier; Galinier, Michel; Lairez, Olivier; Cognet, Thomas

    2018-05-14

    The aim of this study was to evaluate the value of multilayer strain analysis to the assessment of myocardial viability (MV) through the comparison of both speckle tracking echocardiography and single-photon emission computed tomography (SPECT) imaging. We also intended to determine which segmental longitudinal strain (LS) cutoff value would be optimal to discriminate viable myocardium. We included 47 patients (average age: 61 ± 11 years) referred to our cardiac imaging center for MV evaluation. All patients underwent transthoracic echocardiography with measures of LS, SPECT, and coronary angiography. In all, 799 segments were analyzed. We correlated myocardial tracer uptake by SPECT with sub-endocardial, sub-epicardial, and mid-segmental LS values with r = .514 P Multilayer strain analysis does not evaluate MV with more accuracy than standard segmental LS analysis. © 2018 Wiley Periodicals, Inc.

  4. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  5. Prediction of functional recovery after primary PCI using the estimate of myocardial salvage in gated SPECT early after acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Calabretta, Raffaella; Castello, Angelo; Linguanti, Flavia; Tutino, Francesca; Ciaccio, Alfonso; Sciagra, Roberto [University of Florence, Nuclear Medicine Unit, Department of Experimental and Clinical Biomedical Sciences ' ' Mario Serio' ' , Florence (Italy); Giglioli, Cristina [Careggi University Hospital, Cardiothoracovascular Department, Florence (Italy)

    2018-04-15

    Primary percutaneous coronary intervention (PCI) in acute myocardial infarction (AMI) aims to achieve myocardial salvage (MS). Because the reference method for measuring MS requires myocardial perfusion imaging (MPI) after tracer injection before PCI, alternative approaches have been proposed, but none has gained wide acceptance. Gated SPECT MPI can assess infarct size (IS), but can also show myocardial stunning. Thus, we compared functional and perfusion abnormalities early after AMI to estimate MS, and to predict left ventricular ejection fraction (LVEF) recovery at follow-up. We studied 120 patients with AMI. Gated SPECT MPI was performed early (before hospital discharge) and at 6 months after AMI to measure IS, MS and functional outcome. MS was defined as the difference between the number of segments with abnormal thickening (i.e. the stunned area or area at risk) and the number of segments with abnormal perfusion (i.e. the final IS), expressed as a percentage of the total number of segments in the AHA model. LVEF was calculated using quantitative gated SPECT. The area at risk was 40 ± 25%, IS was 17.3 ± 16% and MS was 22 ± 19%. Early LVEF was 46.6 ± 11.6% and late LVEF was 51.4 ± 11.6%, with 54 patients showing at least an increase in LVEF of more than 5 units. ROC analysis showed that MS was able to predict LVEF recovery with an area under the curve (AUC) of 0.79 (p < 0.0001), and using a cut off >23% detected LVEF recovery with 74% sensitivity and 71% specificity. Conversely, IS was associated with an AUC 0.53 (not significant). MS assessed by a single early gated SPECT MPI study can accurately predict LVEF evolution after primary PCI for AMI. (orig.)

  6. Utility of the combination of DAT SPECT and MIBG myocardial scintigraphy in differentiating dementia with Lewy bodies from Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Namioka, Nayuta; Hatanaka, Hirokuni; Hirose, Daisuke; Fukasawa, Raita; Umahara, Takahiko; Sakurai, Hirohumi; Hanyu, Haruo [Tokyo Medical University, Department of Geriatric Medicine, Shinjuku-ku, Tokyo (Japan)

    2016-01-15

    {sup 123}I-2β-Carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl) nortropane ({sup 123}I-FP-CIT) dopamine transporter single photon emission computed tomography (DAT SPECT) and {sup 123}I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy can be used to assist in the diagnosis of patients with dementia with Lewy bodies (DLB). We compared the diagnostic value of these two methods in differentiating DLB from Alzheimer's disease (AD). Furthermore, we evaluated whether a combination of DAT SPECT and MIBG myocardial scintigraphy would provide a more useful means of differentiating between DLB and AD. Patients with AD (n = 57) and patients with DLB (n = 76) who underwent both DAT SPECT and MIBG myocardial scintigraphy were enrolled. The sensitivity, specificity, and accuracy of both methods as well as their combination for differentiating DLB from AD were calculated. Moreover, we examined whether symptoms of the patients with DLB were associated with the patterns of the abnormalities displayed on DAT SPECT and MIBG myocardial scintigraphy. The sensitivity and specificity of differentiating DLB from AD were 72.4 and 94.4 % by the heart to mediastinum ratio of MIBG uptake, 88.2 and 88.9 % by the specific binding ratio on DAT SPECT, and 96.1 and 90.7 % by their combination, respectively. The combined use of DAT SPECT and MIBG myocardial scintigraphy enabled more accurate differentiation between DLB and AD compared with either DAT SPECT or MIBG myocardial scintigraphy alone. There was a significantly higher frequency of parkinsonism in the abnormal DAT SPECT group than the normal DAT SPECT group. On the other hand, there was a higher frequency of the appearance of rapid eye movement (REM) sleep behavior disorder in the abnormal MIBG uptake group than the normal MIBG uptake group. These results suggested that using a combination of these scintigraphic methods is a useful and practical approach to differentiate DLB from AD. (orig.)

  7. Impact of patient motion on myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Huang Kemin; Feng Yanlin; He Xiaohong; Wen Guanghua; Yu Fengwen; Liu Shusheng; Liu Dejun; Yuan Jianwei; Yang Ming

    2008-01-01

    Objective: It is well known that patient motion may cause artifacts in myocardial SPECT images and affect clinical diagnosis. The aim of the study was to evaluate the effects of motion on quality and semi-quantitative results of myocardial perfusion images. Methods: Six healthy volunteers un- derwent myocardial perfusion SPECT. The raw data in each case was manually shifted 1-6 frames and 1 4 pixels, respectively by using the motion correction software. The shifted raw data were then reconstructed. A semi-quantitative software was used to assess the myocardial perfusion of left ventricle. The quality and semi-quantitative results of the tomographic images reconstructed from the raw data with and without motion were compared and analyzed. SPSS 12.0 was used for data analysis. Results: There was no visible artifact and semi-quantitative difference on the data with 1 frame and (or) 1 pixel shift when compared with the original data without shift. The image artifacts became significantly deteriorated when the number of flame and (or) pixel shift was increased. In general, the image artifact of inferior and posterior wall was related to the upward shift, and that of anterior and infero-posterior wall was related to the downward shift, that of septal, anterior, infero-postefior wall and apex was related to right-ward shift, and the septal and infero-posterior wall was related to the left-ward shift. The differences along the x-axis shift were more prominent than that of the y-axis (t=2.848, P<0.01), and the differences in the downward and rightward shift were more severe than the upward and leftward shift (t=2.941, 6.598; all P<0.01), respectively. Conclusions: Image artifacts became significant when there was motion induced by manual shift of more than one flame and (or) one pixel. Different motion directions were closely related to different segments of left ventricle. (authors)

  8. Diagnostic value of exercise induced 18F-FDG myocardial metabolism scintigraphy in myocardial ischemia

    International Nuclear Information System (INIS)

    Shen Rui; He Zuoxiang; Shi Rongfang; Liu Xiujie; Tian Yueqin; Guo Feng; Wei Hongxing; Wu Yongjian; Qin Xuewen; Gao Runlin

    2006-01-01

    Objective: To evaluate the feasibility and diagnostic accuracy of exercise induced myocardial imaging with 18 F-fluorodeoxyglucose (FDG) in myocardial ischemia. Methods: Twenty-six patients with known or suspected coronary artery, disease (CAD) and with no prior myocardial infarction underwent simultaneous myocardial perfusion and metabolism imaging following intravenous injection of 99 Tc m -methoxy-isobutylisonitrile ( 99 Tc m -sestamibi) and 18 F-FDG at peak exercise. Subsequently rest perfusion imaging and coronary angiography (CAG) were performed in all patients. Exercise 18 F-FDG myocardial imaging was compared with 99 Tc m -sestamibi imaging and CAG. Results: In 22 patients with ≥50% narrowing over l coronary artery, 18 had perfusion abnormalities (sensitivity 82%), whereas 20 had abnormal myocardial 18 F-FDG uptake (sensitivity 91%, P>0.05). Patients with reversible (12 cases) or partial reversible (3 cases) perfusion abnormalities had increased myocardial 18 F-FDG uptake in abnormal perfusion segments. Compared with CAG, perfusion defect was seen in myocardial segments corresponding to 25 vascular territories of 51 vessels with ≥50% narrowing in 22 patients in 99 Tc m -sestamibi imaging (sensitivity 49%), whereas increased 18 F-FDG uptake was seen in 34 vascular territories (sensitivity 67%, P=0.008). Conclusions: Exercise induced myocardial ischemia can be imaged directly with 18 F-FDG. Combined exercise 18 F-FDG and 99 Tc m -sestamibi imaging provides a better assessment of exercise-induced myocardial ischemia as compared with exercise-rest perfusion imaging. (authors)

  9. Relationship between coronary contrast-flow quantitative flow ratio and myocardial ischemia assessed by SPECT MPI

    Energy Technology Data Exchange (ETDEWEB)

    Smit, Jeff M.; Rosendael, Alexander R. van; Jukema, J.W.; Delgado, Victoria; Bax, Jeroen J.; Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Koning, Gerhard [Medis Medical Imaging Systems B.V., Leiden (Netherlands); Dibbets-Schneider, Petra [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Mertens, Bart J. [Leiden University Medical Center, Department of Medical Statistics, Leiden (Netherlands); Reiber, Johan H.C. [Medis Medical Imaging Systems B.V., Leiden (Netherlands); Leiden University Medical Center, Department of Radiology, Leiden (Netherlands)

    2017-10-15

    A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called ''contrast-flow quantitative flow ratio (cQFR)''. Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p <0.001). A good relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters. (orig.)

  10. Reverse redistribution phenomenon on rest 99mTc-tetrofosmin myocardial single photon emission computed tomography involves impaired left ventricular contraction in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Kurokawa, Kazuyuki; Ohte, Nobuyuki; Miyabe, Hiromichi; Akita, Sachie; Yajima, Kazuhiro; Hayano, Junichiro; Kimura, Genjiro

    2003-01-01

    The purpose of this study was to investigate the clinical significance of the reverse redistribution (RR) phenomenon on technetium-99m ( 99m Tc)-tetrofosmin myocardial single photon emission computed tomography (SPECT) performed at rest. Twenty-five patients underwent myocardial SPECT 3 weeks after the onset of acute myocardial infarction. Myocardial images were acquired at 40 min (early) and 4 h (delayed) after the injection of 740 MBq of 99m Tc-tetrofosmin. The regional myocardial uptake of the tracer in 26 segments of the left ventricular (LV) wall was visually scored from 0 (no activity) to 3 (normal activity), and then the RR was defined as a decrease of more than 1 point in the activity score on the delayed image compared with that on the early image. Regions with an activity score of 3 on both the early and delayed images were defined as normal, and those with a score of 0 or 1 on the early image were considered to have a fixed defect. The regional myocardial 99m Tc-tetrofosmin uptake and washout rate were also quantitatively assessed in each region. In addition, exercise stress electrocardiograph-gated SPECT with 99m Tc-tetrofosmin was performed within 1 week of the rest study, and the percent count increase (%CI) during myocardial contraction in each corresponding region was studied. RR was observed in 18 of the 25 patients. The regional washout rate of 99m Tc-tetrofosmin was significantly higher in the RR regions (45.0±3.8%) than in either the normal regions (36.4±4.1%, p 99m Tc-tetrofosmin SPECT have severely impaired LV wall contraction after exercise. (author)

  11. Gated-SPECT myocardial scintigraphy in left bundle branch block: A study in patients with and without coronary artery disease

    International Nuclear Information System (INIS)

    Falcao, A.M.; Moffa, P.J.; Chalela, W.A.; Soares, J.; Oliveira, C.G.; Kreling, J.C.; Ferreira, B.A.; Uchida, A.H.; Meneghetti, J.C.

    2002-01-01

    Introduction: Myocardial perfusion scintigraphy (MPS) is a non-invasive method helpful for evaluating coronary heart disease. In left bundle branch block (LBBB), the myocardial scintigraphy frequently reveals septal abnormalities in the absence of coronary artery disease (CAD) and gives rise to 'false-positive' results in patients (pts) with suspected CAD. The purpose of this study was to assess the diagnostic role of ECG-gated SPECT in pts with complete LBBB, with and without known CAD. Methods. This study included 46 pts, 29 women (63%), with mean age 63.8 ± 11.6yr, divided into two groups: Group 1 (n=21 pts) with LBBB and CAD angiographically confirmed and Group 2 (n=25 pts) with LBBB and normal coronangiography. All pts underwent MPS at rest and two stress tests - dipyridamole (DIP) and treadmill exercise test (ET) with Bruce protocol. Myocardial perfusion, wall motility and wall thickening were analyzed qualitatively by consensus of two observers in anterior, septal, inferior, lateral and apical myocardial segments. Scores were attributed to: perfusion as normal, reversible or fixed defects; motility as normal, hypokinesia, akinesia or dyskinesia and thickening if present or absent. The left ventricle ejection fraction (LVEF) was automatically calculated from the ECG-gated SPECT. Results: The comparative analysis between groups 1 and 2 for both stresses (DIP and ET) for the parameters analyzed in the myocardial segments are presented: LVEF at rest, ET and DIP show statistically significant differences between groups 1 and 2 (p<0.0001). Conclusion: In the anterior and septal segments, only septal thickening was capable of differentiating between LBBB with and without CAD, independent of the kind of stress. In the other segments there was no influence of disturbance conduction for the perfusion analysis

  12. ST segment elevation after myocardial infarction: Viability or ventricular dysfunction? Comparison with myocardial scintigraphy

    International Nuclear Information System (INIS)

    Chalela, William Azem; Soares, J. Jr.; Meneghetti, J.C.; Olivera, C.G.; Moffa, P.J.; Falcao, A.M.; Ramires, J.A.F.

    2004-01-01

    The detection of viable myocardium after myocardial infarction is an important indication for revascularization. We compared exercise-induced ST segment elevation with reversibility at Thallium-201 SPECT scintigraphy and regional wall motion assessment by ventriculography. Thirty two patients with previous myocardial infarction and with left ventricular ejection fraction of < 50% were studied. Patients underwent coronary angiography and Thallium-201 SPECT scintigraphy with re-injection protocol before and after coronary artery bypass graft surgery. Group I comprised 11 patients with ST segment elevation during treadmill stress testing. Group II comprised 21 patients without ST segment elevation. Minimal or moderate hypokinesis was present in 2 patients of Group I and in 4 patients of Group II. Nine patients of Group I and 17 patients of Group II had severe hypokinetic, akinetic or dyskinetic myocardium. Scintigraphy revealed reversibility in the myocardial infarction area in 4 patients from Group I (36.4%) and 11 (52.4%) patients from Group II. Improvement in perfusion after coronary artery bypass grafting was observed in 4 patients from Group I and 8 patients from Group II. Sensitivity, specificity, accuracy, and positive and negative predictive values of ST segment elevation were 33.3, 70.6, 55.2, 44.5 and 60% respectively. It was concluded that exercise-induced ST segment elevation after myocardial infarction is present more frequently in cases of severe regional myocardial dysfunction. (author)

  13. Clinical significance of diffuse slow washout pattern (DSWO) on the exercise stress 201Tl SPECT myocardial imaging: Correlative study with influencing factors

    International Nuclear Information System (INIS)

    Wang Qian; Fumiko Nakanishi; Shusuke Sone

    1994-01-01

    DSWO shown on the Bull's eye images was found in 98 of 1234 patients suspected of having coronary artery disease and examined with 201 Tl myocardial SPECT imaging. 48 of these 98 patients underwent coronary arteriography. Comparison studies were performed between Bull's eye SPECT image, coronary arteriography and laboratory data. DSWO was found in 11 cases with single vessel disease (1VD), 18 cases with double vessel disease (2VD) and 21 cases with triple vessel disease (3VD). Three of 58 cases with stenosis of a cardiomyopathy. In the CAD group, DSWO appeared frequently accompanying hypertension, hyperlipemia and diabetes mellitus. These complications tended to increase in patients with 1VD and the stenosis less than 75%

  14. A new dynamic myocardial phantom for evaluation of SPECT and PET quantitation in systolic and diastolic conditions

    International Nuclear Information System (INIS)

    Dreuille, O. de; Bendriem, B.; Riddell, C.

    1996-01-01

    We present a new dynamic myocardial phantom designed to evaluate SPECT and PET imaging in systolic and diastolic conditions. The phantom includes a thoracic attenuating media and the myocardial wall thickness varying during the scan can be performed. In this study the phantom was used with three different wall thickness characteristic of a systolic, end-diastolic and pathologic end-diastolic condition. The myocardium was filled with 99m Tc, 18 F and Gd and imaged by SPECT, PET and MRI. SPECT attenuation correction was performed using a modified PET transmission. A bull's eyes image was obtained for all data and wall ROI were then drawn for analysis. Using MRI as a reference, error from PET, SPECT and attenuation corrected SPECT were calculated. Systolic PET performances agree with MRI. Quantitation loss due to wall thickness reduction compared to the systole. Attenuation correction in SPECT leads to significant decrease of the error both in systole (from 29% to 14%) and diastole (35% to 22%). This is particularly sensitive for septum and inferior walls. SPECT residual errors (14% in systole and 22% in pathologic end-diastole) are likely caused by scatter, noise and depth dependent resolution effect. The results obtained with this dynamical phantom demonstrate the quantitation improvement achieved in SPECT with attenuation correction and also reinforce the need for variable resolution correction in addition to attenuation correction

  15. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this...

  16. Concordance between myocardial perfusion scan assessed by SPECT and fractional flow reserve findings for detection of significant ischemia

    Directory of Open Access Journals (Sweden)

    Morteza Safi

    2016-09-01

    Conclusion: FFR and MPI with SPECT techniques showed significant concordance for detection of myocardial ischemia, regardless of the type of diseased coronary arteries. In this context, SPECT has high sensitivity and NPV for detection of ischemia compared with FFR.

  17. The value of Tc-99m MIBI SPECT during isosorbide dinitrate infusion in assessment of viable myocardium in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Li Shengting; Liu Xiujie; Lu Zongliang

    1996-01-01

    Tc-99m MIBI myocardial SPECT has shown promise for evaluation of coronary artery disease. But its role in predicting myocardial viability is still under investigation. The purpose of this study was to evaluate the value of Tc-99m MIBI myocardial SPECT during isosorbide dinitrate (ISDN) infusion in the assessment of myocardial viability. Thirty-seven patients with previous myocardial infarction (the infarct age ranged from ≤ 30 days to 900 days) were studied, of them 13 patients had Tc-99m MIBI studies before and after coronary artery bypass grafting (CABG). The results showed that out of 134 segments with hypoperfusion at resting SPECT, 56 segments (41.8%) had an increase in Tc-99m MIBI uptake during ISDN infusion. Among them, 17 segments (30.4%) were normalized, 6 segments (10.7%) were significantly improved and 33 segments (58.9%) were improved. The degree of improvement in perfusion was related to the age of the myocardial infarction. In 13 patients with CABG, of 31 segments with improvement in perfusion post CABG, 25 segments (80.6%) showed perfusion improvement during ISDN infusion, and of 28 segments with improved wall motion post CABG, 23 segments (82.1%) showed improvement in perfusion during ISDN infusion. Tc-99m MIBI SPECT during ISDN infusion may therefore be a useful approach for assessing myocardial viability. (author)

  18. Evaluation of latent cardiac disease in diabetic patients with Tl-201 exercise myocardial scintigram and blood pool scintigram

    International Nuclear Information System (INIS)

    Miyashita, Takeo; Kasai, Ryutaro; Ikebe, Nobuhiko; Nagai, Yoshikazu; Yamasawa, Ikuhiro; Ibukiyama, Chiharu; Notoya, Yoko

    1990-01-01

    To find latent heart disease in diabetic patients, 142 diabetic patients were divided into 4 groups: (1) no hypertension and normal ECG (DM group); (2) hypertension recognized clinically (HT group); (3) myocardial damage on ECG (MD group); (4) group associated with the previous 2 (HT+MD group). In all groups Tl-201 exercise myocardial scintigrams and blood pool scintigrams were taken for comparative analysis. Positive rates of SPECT were 27.7% (23/83) in the DM group, 30.0% (9/30) in the HT group, 50.0% (6/12) in the MD group, and 70.6% (12/17) in the HT+MD group. The rate in the HT+MD group was significantly higher than in that of the DM and HT groups (p<0.001, p<0.01). Blood pool scintigrams revealed that in the HT+MD group, as compared with the normal control group, both 1/3 FF and PFR were significantly depressed, in addition to significant TPF prolongation in the former (p<0.001, p<0.05, p<0.05). These findings suggest that in diabetic patients hypertension and myocardial damage would lead to a high incidence of abnormality in SPECT and left ventricular rapid filling dysfunction. This indicate a high incidence of latent cardiac disease which can be recognized in diabetic patients by stress myocardial and blood pool scintigrams. (author)

  19. Reproducibility of the assessment of myocardial function using gated Tc-99m-MIBI SPECT and quantitative software

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Cheon, Gi Jeong; Ahn, Ji Young; Jeong, Joon Ki; Lee, Myung Chul

    1998-01-01

    We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT. We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/-42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml+/-39 ml), and EF from 20% to 68% (51%+/-14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect

  20. SPECT myocardial perfusion imaging. Long-term prognostic value in diabetic patients with and without coronary artery disease

    International Nuclear Information System (INIS)

    Koehli, M.; Monbaron, D.; Gaillard, R.C.; Ruiz, J.; Prior, J.O.; Bischof Delaloye, A.; Calcagni, M.L.; Fivaz-Arbane, M.; Stauffer, J.C.

    2006-01-01

    Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Patients, methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curve and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 ± 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p 5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. (orig.)

  1. Minimizing Patient-Specific Tracer Dose in Myocardial Perfusion Imaging Using CZT SPECT

    NARCIS (Netherlands)

    van Dijk, Joris David; Jager, Pieter L.; Ottervanger, Jan Paul; Slump, Cornelis H.; de Boer, Jaep; Oostdijk, Adrianus H.J.; van Dalen, Jorn A.

    Myocardial perfusion imaging (MPI) with SPECT is widely adopted in clinical practice but is associated with a relatively high radiation dose. The aim of this study was to determine the minimum product of tracer dose and scan time that will maintain diagnostic value for cadmium zinc telluride (CZT)

  2. Comparison of multi-slice CT (MSCT) and TI-201 myocardial SPECT in detection of coronary artery disease: relation to coronary arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S.; Kim, Y. K.; Shim, S. S. [College of Medicine, Univ. of Ewha Womens, Seoul (Korea, Republic of)

    2003-07-01

    To evaluate the diagnostic potentials of MSCT and TI-201 SPECT in the assessment of coronary artery disease. Twenty-four patients (15 men, 9 women, 42-79 years) with clinically suspected coronary artery disease were studied by TI-201 myocardial SPECT and MSCT. MSCT data were obtained with 12 x 0.75 mm, 420ms rotation, multi-slice CT scanner (SOMATOM Sensation, Siemens) using non-ionic contrast, 80ml, 4ml/sec. Multiplanar reconstruction techniques were used for evaluation of coronary arteries. TI-201 myocardial SPECT were performed at stress with adenosine and at rest. Data from MSCT and TI-201 SPECT were compared territory by territory (divided into two segments; LAD and RCA/LCx) and related to coronary arteriography, in which more than 60% stenoses are regarded as significant. MSCT and TI-201 SPECT showed agreement in 37 out of 48 segments (77.1%). Out of 11 disagreed segments (22.9), TI-201 SPECT was superior in 6 segments and MSCT was superior in 5 segments. Sensitivities and specificities of MSCT and TI-201 SPECT by coronary arteriography are 81.8%, 69.2% and 86.3%, 76.9%, respectively. Agreed 4 segments between MSCT and TI-201 SPECT exhibited results that differ from the results of coronary arteriography. Myocardial bridge in two cases were detected as significant stenoses by MSCT but showed normal perfusion in TI-201 SPECT. Agreement between MSCT and TI-201 SPECT in the assessment of coronary artery disease was good but TI-201 SPECT has higher sensitivity and specificity for the detection of jeopardized myocardium than MSCT. MSCT and TI-201 SPECT provide complementary information in the assessment of coronary artery disease and could help reduce probable mistake in the interpretation of hemo dynamically insignificant lesion in coronary arteriography.

  3. Absolute quantitation of myocardial blood flow with 201Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Kim, Kyeong-Min; Nakazawa, Mayumi; Sohlberg, Antti; Zeniya, Tsutomu; Hayashi, Takuya; Watabe, Hiroshi; Eberl, Stefan; Tamura, Yoshikazu; Ono, Yukihiko

    2008-01-01

    201 Tl has been extensively used for myocardial perfusion and viability assessment. Unlike 99m Tc-labelled agents, such as 99m Tc-sestamibi and 99m Tc-tetrofosmine, the regional concentration of 201 Tl varies with time. This study is intended to validate a kinetic modelling approach for in vivo quantitative estimation of regional myocardial blood flow (MBF) and volume of distribution of 201 Tl using dynamic SPECT. Dynamic SPECT was carried out on 20 normal canines after the intravenous administration of 201 Tl using a commercial SPECT system. Seven animals were studied at rest, nine during adenosine infusion, and four after beta-blocker administration. Quantitative images were reconstructed with a previously validated technique, employing OS-EM with attenuation-correction, and transmission-dependent convolution subtraction scatter correction. Measured regional time-activity curves in myocardial segments were fitted to two- and three-compartment models. Regional MBF was defined as the influx rate constant (K 1 ) with corrections for the partial volume effect, haematocrit and limited first-pass extraction fraction, and was compared with that determined from radio-labelled microspheres experiments. Regional time-activity curves responded well to pharmacological stress. Quantitative MBF values were higher with adenosine and decreased after beta-blocker compared to a resting condition. MBFs obtained with SPECT (MBF SPECT ) correlated well with the MBF values obtained by the radio-labelled microspheres (MBF MS ) (MBF SPECT = -0.067 + 1.042 x MBF MS , p 201 Tl and dynamic SPECT. (orig.)

  4. Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Mathias [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim–Heidelberg University, Mannheim (Germany); Nance, John W. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Moscariello, Antonio [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, “A. Gemelli” Hospital, Rome (Italy); Weininger, Markus; Rowe, Garrett W.; Ruzsics, Balazs [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Kang, Doo Kyoung [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Chiaramida, Salvatore A. [Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Schoenberg, Stefan O.; Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim–Heidelberg University, Mannheim (Germany); and others

    2012-12-15

    Purpose: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed tomography (SPECT) for the workup of coronary artery disease (CAD). Materials and methods: A decision and simulation model was developed to estimate cost and health effects of using DECT myocardial perfusion imaging instead of SPECT for identifying patients in need of invasive imaging and possible revascularization. The model was based on the performance indices of stress/rest DECT compared with stress/rest SPECT for detecting myocardial perfusion deficits in 50 patients (mean age 61 ± 10 years) with CAD. Stress/rest perfusion and delayed enhancement cardiac MRI served as reference standard. For DECT a reimbursement of US$1700 was assumed but costs of cardiac MRI were not included in the model. All other actual healthcare costs in these patients were derived from MUSC's hospital billing system. Results: Compared with cardiac MRI, DECT (versus SPECT) had 90% (85%) sensitivity and 71% (58%) specificity for identifying patients with obstructive CAD. Compared with the no imaging and no treatment strategy, routine SPECT gained 13.49 quality-adjusted life-years (QALYs) with an incremental cost-effectiveness ratio (ICER) of US$3557 (in 2010) per QALY. In comparison, DECT ICER was lower (US$3.191 per QALY, p = 0.0002) and an additional 0.64 QALYs was obtained (total of 14.13 QALYs) if compared with the SPECT strategy as well as the no imaging and no treatment strategy. Conclusion: Using DECT as the first-line imaging test for myocardial perfusion for the workup of patients with CAD has the potential to provide gains in QALYs, while lowering costs if compared to routine myocardial perfusion SPECT.

  5. Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease

    International Nuclear Information System (INIS)

    Meyer, Mathias; Nance, John W.; Schoepf, U. Joseph; Moscariello, Antonio; Weininger, Markus; Rowe, Garrett W.; Ruzsics, Balazs; Kang, Doo Kyoung; Chiaramida, Salvatore A.; Schoenberg, Stefan O.; Fink, Christian

    2012-01-01

    Purpose: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed tomography (SPECT) for the workup of coronary artery disease (CAD). Materials and methods: A decision and simulation model was developed to estimate cost and health effects of using DECT myocardial perfusion imaging instead of SPECT for identifying patients in need of invasive imaging and possible revascularization. The model was based on the performance indices of stress/rest DECT compared with stress/rest SPECT for detecting myocardial perfusion deficits in 50 patients (mean age 61 ± 10 years) with CAD. Stress/rest perfusion and delayed enhancement cardiac MRI served as reference standard. For DECT a reimbursement of US$1700 was assumed but costs of cardiac MRI were not included in the model. All other actual healthcare costs in these patients were derived from MUSC's hospital billing system. Results: Compared with cardiac MRI, DECT (versus SPECT) had 90% (85%) sensitivity and 71% (58%) specificity for identifying patients with obstructive CAD. Compared with the no imaging and no treatment strategy, routine SPECT gained 13.49 quality-adjusted life-years (QALYs) with an incremental cost-effectiveness ratio (ICER) of US$3557 (in 2010) per QALY. In comparison, DECT ICER was lower (US$3.191 per QALY, p = 0.0002) and an additional 0.64 QALYs was obtained (total of 14.13 QALYs) if compared with the SPECT strategy as well as the no imaging and no treatment strategy. Conclusion: Using DECT as the first-line imaging test for myocardial perfusion for the workup of patients with CAD has the potential to provide gains in QALYs, while lowering costs if compared to routine myocardial perfusion SPECT.

  6. Clinical evaluation of coronary territory map by using unfolded map of Tl-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa; Nishimura, Tsunehiko; Katafuchi, Tetsuro; Yamagami, Hidetoshi; Kumita, Shinichirou; Hayashida, Kohei; Hayashi, Makoto

    1990-01-01

    Coronary territory map was developed on unfolded map of exercise Tl-201 myocardial SPECT. Each coronary territory was determined by summing the each unfolded map of 54 cases of single vessel disease respectively, and standardizing with normal pattern obtained from normal patients. The diagnostic accuracy of coronary territory map to identify the diseased coronary artery was analyzed in 104 clinical cases and was compared with that of planar and SPECT visual diagnosis, simple unfolded map (raw map) and extent and severity map. The results were as follows. (1) Territory map showed excellent diagnostic accuracy in single or double vessel disease, especially in diagnosis of left circumflex coronary artery lesion. (2) In triple vessel disease, the diagnostic accuracy of territory map or other unfolded maps was 30% at best, and was inferior to planar or SPECT visual analysis. The cause of this inferiority seemed that the quantitatively analyzed map had no information about the degree of Tl-uptake into lung or myocardium, which give useful information in visual diagnosis. (3) The diagnostic agreement ratio in two observers was the highest in territory map diagnosis, so that the territory map diagnosis seemed to be the most objective one. (4) The unfolded map diagnosis with apical display obtained from long-axis tomogram was useful to diagnose left anteior descending coronary (LAD) lesion, which improve not only the sensitivity of LAD but also specificity of right coronary artery single vessel disease. (author)

  7. GATED SPECT TO EVALUATE LEFT VENTRICULAR MYOCARDIAL PERFUSION, FUNCTION AND DYSSYNCHRONY FOR RESYNCHRONIZATION THERAPY

    Directory of Open Access Journals (Sweden)

    E.N. Ostroumov

    2009-01-01

    Full Text Available The study included 15 consecutive patients with heart failure and substantial LV dyssynchrony undergoing CRT. Clinical and phase analysis of gated myocardial perfusion SPECT assessed at baseline, after 2–3 days and after 3–4 months of CRT. The results demonstrated inversely relationship between the response to CRT and the nonviable myocardium. Evaluation of myocardial viability is necessary to considered in the selection process for CRT.

  8. Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hedén Bo

    2009-08-01

    Full Text Available Abstract Background It is of great clinical importance to exclude myocardial infarction in patients with suspected coronary artery disease who do not have stress-induced ischemia. The diagnostic use of myocardial perfusion single-photon emission computed tomography (SPECT in this situation is sometimes complicated by attenuation artifacts that mimic myocardial infarction. Imaging in the prone position has been suggested as a method to overcome this problem. Methods In this study, 52 patients without known prior infarction and no stress-induced ischemia on SPECT imaging were examined in both supine and prone position. The results were compared with cardiac magnetic resonance imaging (CMR with delayed-enhancement technique to confirm or exclude myocardial infarction. Results There were 63 defects in supine-position images, 37 of which disappeared in the prone position. None of the 37 defects were associated with myocardial infarction by CMR, indicating that all of them represented attenuation artifacts. Of the remaining 26 defects that did not disappear on prone imaging, myocardial infarction was confirmed by CMR in 2; the remaining 24 had no sign of ischemic infarction but 2 had other kinds of myocardial injuries. In 3 patients, SPECT failed to detect small scars identified by CMR. Conclusion Perfusion defects in the supine position that disappeared in the prone position were caused by attenuation, not myocardial infarction. Hence, imaging in the prone position can help to rule out ischemic heart disease for some patients admitted for SPECT with suspected but not documented ischemic heart disease. This would indicate a better prognosis and prevent unnecessary further investigations and treatment.

  9. Determination of optimum filter in inferolateral view of myocardial SPECT

    International Nuclear Information System (INIS)

    Takavar; Eftekhari, M.; Fallahi, B.; Shamsipour, Gh.; Sohrabi, M.; Saghari, M.

    2004-01-01

    Background: In myocardial perfusion SPECT imaging, images are degraded by photon attenuation, distance-dependent collimator, detector response and photon scattering. As filters greatly affect quality of nuclear medicine images, in this study determination of optimum filter for inferolateral view is our prime objective. Materials and Methods: .A phantom simulating heart left ventricle was built. About 1mCi of 99m Tc, was injected into the phantom. Images were taken from this phantom. Parzen, Hamming, Hanning, Butter worth and Gaussian filters were exerted on the images obtained from the phantom.. By defining some criteria such as contrast, signal to noise ratio, and defect size delectability, the best filter was determined for our ADAC spect system at our nuclear medicine center. In this study, 27 patients who previously had undergone coronary angiography were chosen to be included. All of these patients revealed significant stenosis in the left circumflex artery. Myocardial SPECT images of these patients had inferolateral defect. The images of these patients were processed with 12 filters including the optimum filters obtained from phantom study and some other non-optimum filters. A nuclear medicine physician quantified the results by assigmng mark from 0 to 4. to every image. 0 mark for images that didn't show the defect properly and 4 for the best one. The data from patient study were analyzed with non-related, non -parametric Friedman test. Results: Nyquist frequency of 0.325 and 0.5 were obtained as the optimum cut-off frequencies for hamming and Hanning filters respectively. Order 11 and cut-off frequency of 0.45 and order 20. with cut-off frequency of 0.5 were found to be optimum for Butter worth and Gaussian filters. In patient studies it was found that, Butter worth filter with cut-off frequency of 0.45 and order of 11 produced the best quality images. Conclusion: In this study. Butter worth filter with cut-off frequency of 0.45 and order of 11 was the

  10. Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lim, Il Han; Kim, Ki Bong; Lee, Dong Soo

    2008-01-01

    Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F=28:27) of low-likelihood for coronary artery disease were enrolled and 201 Tl rest / 99m Tc-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. 201 Tl rest / 99m Tc-MIBI stress / 201 Tl 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, Q delay (perfusion measurement), Δ delay (Q delay .m) and Z delay ((Q delay .m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was 51.8±6.5 and the highest segmental perfusion was 87.0±5.9, and they are 58.7±8.1 and 87.3±6.0, respectively in women. In the viability assessment, Q delay showed AUC of 0.633, while those for Δ delay and Z delay were 0.735 and 0.716, respectively. The AUCs of Δ delay and Z delay were significantly higher than that of Q delay (p=0.001 and 0.018, respectively). The diagnostic performance of Δ delay , which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. On automatic

  11. Myocardial Perfusion SPECT 2015 in Germany

    Science.gov (United States)

    Burchert, Wolfgang; Schäfer, Wolfgang; Hacker, Marcus

    2016-01-01

    Summary Aim The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine presents the results of the 7th survey of myocardial perfusion SPECT (MPS) of the reporting year 2015. Method 268 questionnaires (173 practices [PR], 67 hospitals [HO], 28 university hospitals [UH]) were evaluated. Results of the last survey from 2012 are set in squared brackets. Results MPS of 121 939 [105 941] patients were reported. 98 % [95 %] of all MPS were performed with Tc-99m radiopharmaceuticals and 2 % [5 %] with Tl-201. 78 % [79 %] of all patients were studied in PR, 14 % [15 %] in HO, and 8 % [6 %] in UH. A pharmacological stress test was performed in 43 % [39 %] (22 % [24 %] adenosine, 20 % [9 %] regadenoson, 1% [6 %] dipyridamole or dobutamine). Attenuation correction was applied in 25 % [2009: 10 %] of MPS. Gated SPECT was performed in 78 % [70 %] of all rest MPS, in 80 % [73 %] of all stress and in 76 % [67 %] of all stress and rest MPS. 53 % [33 %] of all nuclear medicine departments performed MPS scoring by default, whereas 24 % [41 %] did not apply any quantification. 31 % [26 %] of all departments noticed an increase in their counted MPS and 29 % [29 %] no changes. Data from 89 departments which participated in all surveys showed an increase in MPS count of 11.1 % (PR: 12.2 %, HO: 4.8 %, UH: 18.4 %). 70 % [60 %] of the MPS were requested by ambulatory care cardiologists. Conclusion The 2015 MPS survey reveals a high-grade adherence of routine MPS practice to current guidelines. The positive trend in MPS performance and number of MPS already observed in 2012 continues. Educational training remains necessary in the field of SPECT scoring. PMID:27909712

  12. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  13. Reduction of the influence of the liver uptake to the myocardial uptake on technetium-99m myocardial SPECT. Usefulness and problems of a mask processing method

    Energy Technology Data Exchange (ETDEWEB)

    Takaki, Akihiro; Okada, Kazuhiro; Urata, Johji; Matsuda, Hirofumi; Takao, Yuji [Saiseikai Kumamoto Hospital (Japan)

    1999-07-01

    The aim of this study is to evaluate the usefulness of a mask processing method for obtaining the true myocardial tracer distribution by eliminating the influence of the liver uptake to the myocardial uptake on myocardial SPECT images by using technetium-99m ({sup 99m}Tc) blood flow agents. A SPECT imaging was performed with a two-head SPECT system (GCA-7200A/DI) in both phantom and clinical studies. The mask processing method was applied to the reconstructed and projection images. The phantom consisted of heart, lung, liver and spine. A defect was located in the inferior wall of the left ventricle and other parts of the heart and liver were filled with {sup 99m}Tc solution. For clinical study 10 patients with difficulty in the interpretation of the inferior wall were selected for the evaluation of usefulness of the mask method. In the phantom study, the mask processing method applied to the reconstructed images was able to remove the overlapped liver from the heart, but was not able to remove the influence of the liver uptake to the myocardial uptake. Nevertheless, the mask processing method applied to the projection images successfully eliminated not only the overlapped liver but also the influence of the liver uptake to the myocardial uptake. In the clinical study, the liver uptake could be removed from the uptake in the inferior wall in 8 of 10 patients with the mask processing methods. In 2 patients, the overlapped liver uptake could not be eliminated from the uptake in the inferior wall because the distance between the liver and heart was too short. The mask processing method applied to the projection images was thought to be superior to that applied to the reconstruction images in both phantom and clinical studies. The mask processing method, especially applied to the projection images, seems to be useful for the elimination of the liver uptake from the inferior wall of the myocardium on myocardial SPECT images using {sup 99m}Tc blood flow agents. (author)

  14. Reduction of the influence of the liver uptake to the myocardial uptake on technetium-99m myocardial SPECT. Usefulness and problems of a mask processing method

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Okada, Kazuhiro; Urata, Johji; Matsuda, Hirofumi; Takao, Yuji

    1999-01-01

    The aim of this study is to evaluate the usefulness of a mask processing method for obtaining the true myocardial tracer distribution by eliminating the influence of the liver uptake to the myocardial uptake on myocardial SPECT images by using technetium-99m ( 99m Tc) blood flow agents. A SPECT imaging was performed with a two-head SPECT system (GCA-7200A/DI) in both phantom and clinical studies. The mask processing method was applied to the reconstructed and projection images. The phantom consisted of heart, lung, liver and spine. A defect was located in the inferior wall of the left ventricle and other parts of the heart and liver were filled with 99m Tc solution. For clinical study 10 patients with difficulty in the interpretation of the inferior wall were selected for the evaluation of usefulness of the mask method. In the phantom study, the mask processing method applied to the reconstructed images was able to remove the overlapped liver from the heart, but was not able to remove the influence of the liver uptake to the myocardial uptake. Nevertheless, the mask processing method applied to the projection images successfully eliminated not only the overlapped liver but also the influence of the liver uptake to the myocardial uptake. In the clinical study, the liver uptake could be removed from the uptake in the inferior wall in 8 of 10 patients with the mask processing methods. In 2 patients, the overlapped liver uptake could not be eliminated from the uptake in the inferior wall because the distance between the liver and heart was too short. The mask processing method applied to the projection images was thought to be superior to that applied to the reconstruction images in both phantom and clinical studies. The mask processing method, especially applied to the projection images, seems to be useful for the elimination of the liver uptake from the inferior wall of the myocardium on myocardial SPECT images using 99m Tc blood flow agents. (author)

  15. Usefulness of {sup 201}Tl myocardial perfusion SPECT in prediction of left ventricular remodeling following an acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seok Nam; Park, C. H.; Hwang, Kyung Hoon [Ajou Univ. College of Medicine, Suwon (Korea, Republic of)

    2000-02-01

    We investigated the role of myocardial perfusion SPECT in prediction of ventricular dilatation and the role of revascularization including thrombolytic therapy and PTCA in prevention of ventricular dilatation after an acute myocardial linfarction (AMI). We performed dipyridamole stress, 4 hour redistribution, and 24 hour reinjection Tl-201 SPECT in 6 patients with AMI two to nine days after attack. Perfusion and wall motion abnormalities were quantified by perfusion index(PI) and wall motion index (WMI). Left ventricular ejection fraction (LVEF), WMI and ventricular volume were measured within 1 week of AMI and after average of 6 months. According to serial changes of left ventricular end-diastolic volume (LVEDV), patients were divided into two groups. We compared WMI, PI and LVEF between the two groups. Relationships among degree of volume, stress-rest PI, WMI, CKMB,Q wave, LVEF and revascularization were analysed using multivariate analysis. Only initial rest perfusion index was significantly different between the two groups (p<0.05). While initial LVEF, stress PI, CKMB, trial of revascularization procedure, presence of Q wave and WMI were not significantly different between the two groups. Eight of 16 patients (50%) showed LV dilatation on follow-up echocardiography. Three of 3 patients (100%) who did not undergo revascualrization procedure documented LV dilatation. And only 5 (38%) of the remaining 13 patients who underwent revascularization revealed LV dilatation. There was no difference in infarct location between the two groups. By multivariate linear regression analysis in patients only undergoing revascularization, rest perfusion index was the only significant factor. Myocardial perfusion SPECT performed prior to revascularization was useful in prediction of LV dilatation after an AMI. Rest perfusion index on myocardial perfusion plays as a significant predictor of left ventricular dilatation after AMI. And revascularization appears to be a valuable

  16. Use of atropine in patients with submaximal heart rate during exercise myocardial perfusion SPECT.

    Science.gov (United States)

    De Lorenzo, Andrea; Foerster, James; Sciammarella, Maria G; Suey, Cathy; Hayes, Sean W; Friedman, John D; Berman, Daniel S

    2003-01-01

    Failure to reach 85% of maximal predicted heart rate (MPHR) during exercise may render a myocardial perfusion single photon emission computed tomography (MPS) study nondiagnostic for ischemia detection. Although commonly used to increase heart rate (HR) during dobutamine stress, the administration of atropine for patients failing to achieve 85% of MPHR during exercise performed for MPS is still infrequent. Patients undergoing dual-isotope MPS were considered candidates for the study when, during exercise treadmill testing, they had less than 85% of MPHR and were unable to continue because of fatigue, without an ischemic response. Forty-seven patients (aged 65.3 +/- 12.5 years, 78.7% men) received atropine (0.6-1.2 mg). Maximal HR achieved before and after atropine was 118.0 +/- 14.8 beats/min (76.3% +/- 6.2% of MPHR) and 146.4 +/- 12.6 beats/min (94.4% +/- 8.1% of MPHR), respectively (P < .001). Of patients, 44 (93.6%) reached at least 85% of MPHR after atropine and had diagnostic MPS studies. After atropine, arrhythmias occurred in 14 patients (29.8%) and other minor side effects in 1 (2.1%). Atropine allows patients initially failing to achieve 85% of MPHR during exercise to increase HR and have a diagnostic MPS study, without major complications. It may provide an alternative to pharmacologic stress for patients with a blunted HR response to exercise.

  17. Reduction of the LVEF measured with gSPECT after 1-3 hours after physical exercise in CAD

    International Nuclear Information System (INIS)

    Cholewinski, W.; Stefaniak, B.; Poniatowicz-Frasunek, E.; Tarkowska, A.

    2004-01-01

    Aim: It has been shown that exercise may lead to the myocardial stunning with reduction of LVEF, persisting for some time despite recovery of perfusion. The aim of this study was to check whether the post-stress decrease of LVEF lasts as long as 3h after exercise. Patients, methods: The study was performed in 46 patients with CAD and in 10 normals (NMS). All patients underwent myocardial gSPECT after 99m Tc-tetrofosmin injection at rest and during stress with 2-day protocol. SPECT was started 1h after tracer injection at rest (R) and twice: 1h (S1) and 3hs(S3) after injection at stress. LVEF was calculated by the method of Germano et al. Results: All LVEF values were significantly lower in CAD patients than in the control group. In NMS mean LVEF was at rest similar to those obtained 1h and 3h after stress injection (59.0 ± 4.1, 60.0 ± 5.9, 58.0 ± 4.6, respectively; p > 0.05). A post-exercise decrease of LVEF was observed in 2 normal patients both at S1 and at S3. In CAD group LVEF values were lower at S1 than at R (50.8 ± 13.6 versus 49.3 ± 12.8; p < 0.05) and at S3 were lower than at S1 (49.3 ± 12.8 versus 46.0 ± 12.2; p < 0.001). A significant decrease of LVEF was found in 18/46 patients 1h post stress and in 36/46 3h post stress. In patients with reversible perfusion decrease, a significant correlation was found between post-exercise deterioration of perfusion and post-exercise LVEF reduction both at S1 (r = 0.744; p < 0.02) and at S3 (r = 0.734; p < 0.02). Stress induced decrease in LVEF correlated also with severity of perfusion abnormalities. Conclusions: In the majority of patients with CAD physical stress applied for diagnostic purposes results in an impairment of the LV function. A decrease of the LVEF is observed 1h after exercise, but it increases in frequency and grows stronger during the next 2h.The post-stress LVEF reduction is related to the severity of perfusion abnormalities. Patients with CAD who underwent diagnostic stress test should

  18. Comparison of adenosine and exercise stress 201Tl myocardial perfusion imaging for diagnosing coronary heart disease in women

    International Nuclear Information System (INIS)

    Li Jiangjin; Ma Shuren; Meng Tao; Bao Zhi; Cui Jianhe

    2011-01-01

    Objective: To compare the diagnostic value of adenosine and exercise stress myocardial perfusion imaging (MPI) for detecting coronary heart disease (CHD) in women. Methods: One hundred and thirty-eight patients with CHD were randomly divided into two groups: adenosine stress group (n=69)and exercise stress group (n=69). All patients underwent myocardial SPECT evaluation. Coronary angiography (CAG), referred as 'gold standard' , was performed in each patient within 1 week before or after MPI. The diagnostic value of the two stress MPI was compared with χ 2 test or Fisher's exact test. Results: In adenosine stress group, the sensitivity, negative predictive value and accuracy were 88.2% (45/51), 72.7% (16/22), 88.4% (61/69), respectively, which were not significantly different from those of the exercise stress group (91.7% (44/48), 66.7% (8/12), 81.2% (52/64); χ 2 =0.571, 0.714, 0.249, P>0.05). However, the false positive rate of adenosine stress (11.1%, 2/18) was significantly lower than that of exercise stress (50.0%, 8/16), P=0.023. Conclusions: Adenosine and exercise stress MPI have similar value for CHD diagnosis in women, however, adenosine stress MPI may have an advantage of low false positive rate. (authors)

  19. Evaluation of Parallel and Fan-Beam Data Acquisition Geometries and Strategies for Myocardial SPECT Imaging

    Science.gov (United States)

    Qi, Yujin; Tsui, B. M. W.; Gilland, K. L.; Frey, E. C.; Gullberg, G. T.

    2004-06-01

    This study evaluates myocardial SPECT images obtained from parallel-hole (PH) and fan-beam (FB) collimator geometries using both circular-orbit (CO) and noncircular-orbit (NCO) acquisitions. A newly developed 4-D NURBS-based cardiac-torso (NCAT) phantom was used to simulate the /sup 99m/Tc-sestamibi uptakes in human torso with myocardial defects in the left ventricular (LV) wall. Two phantoms were generated to simulate patients with thick and thin body builds. Projection data including the effects of attenuation, collimator-detector response and scatter were generated using SIMSET Monte Carlo simulations. A large number of photon histories were generated such that the projection data were close to noise free. Poisson noise fluctuations were then added to simulate the count densities found in clinical data. Noise-free and noisy projection data were reconstructed using the iterative OS-EM reconstruction algorithm with attenuation compensation. The reconstructed images from noisy projection data show that the noise levels are lower for the FB as compared to the PH collimator due to increase in detected counts. The NCO acquisition method provides slightly better resolution and small improvement in defect contrast as compared to the CO acquisition method in noise-free reconstructed images. Despite lower projection counts the NCO shows the same noise level as the CO in the attenuation corrected reconstruction images. The results from the channelized Hotelling observer (CHO) study show that FB collimator is superior to PH collimator in myocardial defect detection, but the NCO shows no statistical significant difference from the CO for either PH or FB collimator. In conclusion, our results indicate that data acquisition using NCO makes a very small improvement in the resolution over CO for myocardial SPECT imaging. This small improvement does not make a significant difference on myocardial defect detection. However, an FB collimator provides better defect detection than a

  20. Coronary artery stenosis and occlusion: value of 99Tcm-MIBI SPECT

    International Nuclear Information System (INIS)

    Gyoengyoesi, M.; Maul, F.-D.; Standke, R.; Klepzig, H. Jr.; Kaltenbach, M.; Hoer, G.

    1994-01-01

    The aim of this study was to evaluate and validate a new quantification method for 99 Tc m -sestamibi single photon emission computed tomographic (SPECT) myocardial imaging based on a four-slice analysis method and to check the functional results of percutaneous transluminal coronary angioplasty (PTCS). Using the calculated pathological area of the scintigram as an index for myocardial ischaemia, the overall sensitivity was 81-90% and the overall specificity was 74-98%. Analysis of variance of the repeated measurements revealed good reproducibility (coefficient of variation 8.4%). A significant correlation was found between the size of the exercise-induced perfusion defects and the degree of coronary stenosis. The comparison of radionuclide ventriculography and the perfusion image in 27 patients revealed a good correlation between the resting global ejection fraction and myocardial perfusion, but there was no correlation during exercise, indicating a dissociation between myocardial perfusion and function during exercise conditions in patients with coronary artery disease (CAD). (author)

  1. Application of 99mTc-MIBI myocardial tomography imaging for the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Chen Jinshui

    1992-01-01

    99m Tc-MIBI myocardial tomography imaging was obtained from 119 cases with Sopha Medical SPECT system. 38 cases of coronary heart diseases, 33 cases of coronary heart diseases combined with hypertension and 48 cases of myocardial infarction were diagnosed according to clinical symptoms and signs, ECG, exercise ECG (treadmill test) and other laboratory studies. The results showed that positive rate of myocardial thermography imaging for detecting coronary heart disease was 70.21% at rest, and the positivity can be further increased by myocardial tomography imaging with exercise test. On the contrary the positivity of exercise ECG was only 63.8%. It was concluded that radionuclide myocardial tomography imaging was noninvasive and more sensitive and specific than the exercise ECG in detecting coronary heart disease

  2. Usefulness of BMIPP SPECT to evaluate myocardial viability, contractile reserve and coronary stenotic progression after reperfusion in acute myocardial infarction

    International Nuclear Information System (INIS)

    Katsunuma, Eita; Kurokawa, Shingo; Takahashi, Motoi; Fukuda, Naoto; Kurosawa, Toshiro; Izumi, Tohru

    2001-01-01

    Using combined 123 I-BMIPP (BMIPP), 201 Tl (Tl) and 99m Tc-PYP (PYP) myocardial SPECT imaging, risk areas of acute myocardial infarction were documented in the acute stage, and then these images were evaluated for how well they reflected muscle viability, contractile reserve and coronary stenotic progression subsequent to reperfusion therapy. Patients who only experienced a first attack of myocardial infarction were enrolled. In total, 36 cases who had had the occluded artery successfully reperfused were examined during the past year. They had no significant vessel disease except for the culprit single artery. The patients were comprised of 32 men and 4 women. The mean age was 59.5 years. All patients underwent coronary angiography and left ventricular (LV) angiography in the emergency room. BMIPP/Tl and PYP myocardial SPECT were conducted in the acute stage and chronic stage. In the chronic stage LV angiography was repeated to assess the improvement of LV wall motion. The response to postextrasystolic potentiation (PESP) testing was performed to estimate myocardial contractile reserve. The risk area of acute myocardial infarction (AMI) was documented by reduced BMIPP accumulation. The size of reduced BMIPP accumulation was larger than that of PYP accumulation. A BMIPP/Tl discrepancy and PYP accumulation were documented to assess myocardial viability. Both improvement in LV wall motion and augmentation of PESP response were more closely related to a BMIPP/Tl discrepancy in the presence or absence of PYP accumulation. Therefore, it would be possible to evaluate myocardial viability and contractile reserve by the BMIPP/Tl discrepancy. In patients with good viability, it is important to predict whether there is coronary stenotic progression or not. In this study, we demonstrated that most patients with improved BMIPP images had no significant progression at the site of intervention. Serial observation of BMIPP images from the acute stage to the chronic stage might

  3. Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    International Nuclear Information System (INIS)

    Hsu, Bailing; Chen, Fu-Chung; Chen, Chien-Cheng; Wu, Tao-Cheng; Huang, Wen-Sheng; Hou, Po-Nien; Hung, Guang-Uei

    2014-01-01

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or 99m Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a conventional SPECT/CT system and the flow quantitation method is a clinically effective approach to enhance CAD detection. (orig.)

  4. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation

    International Nuclear Information System (INIS)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E.

    2005-01-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis

  5. Clinical Characteristics and Findings of 99mTc-MIBI Heart SPECT in Patients with Acute Myocardial Infarction with Normal Coronary Arteriography

    International Nuclear Information System (INIS)

    Park, Myung Jae; Choi, Tae Youl; Kim, Deong Yoon; Kang, Heung Sun; Choue, Chung Whee; Kim, Kwon Sam; Kim, Kwang Won; Kim, Myung Shick; Song, Jung Sang; Bae, Jong Hoa

    1993-01-01

    Among 64 patients with acute myocardial infarction who underwent coronary angiography, 7 patients (10.9%)showed normal coronary artery. Six patients were men and 1 patient was female. The mean age of patients were 31.1 ± 3.9 years. Among the risk factors of coronary heart disease, smoking was most probable factor in patients with acute myocardial infarction with normal coronary angiography. 99m Tc-MIBI heart SPECT performed 5 of 7 patients and showed that it could be used in diagnosis, localization, extent of infarct area in patients with acute myocardial infarction with normal coronary angiography. But follow up 99m Tc-MIBI heart SPECT study will be needed to define the ability of myocardial viability in this patients.

  6. Myocardial ischemia in Kawasaki disease

    International Nuclear Information System (INIS)

    Fukuda, Tsuyoshi

    1993-01-01

    The detection of myocardial ischemia is essential for evaluation of patients with Kawasaki disease, especially who have had coronary artery lesions. To evaluate the clinical efficacy of Tl-201 single photon emission computed tomography (SPECT) after dipyridamole infusion (maximum dose 0.70 mg/kg) for detecting myocardial ischemia, 44 patients with Kawasaki disease aged 7.7±4.8 years at the study and 10 age matched controls were observed. In the Kawasaki disease group, significant coronary artery stenosis was observed in 14, coronary aneurysm without stenosis in 18, the regression of the coronary aneurysms in 2 and without coronary lesions in 10 patients. In 24 of 44 patients, treadmill exercise stress test was also performed at the same period. Myocardial ischemic changes were observed in 11 patients, all combined with significant coronary artery stenosis. The sensitivity of SPECT for detection of overall coronary stenosis was 79%, coronary that of treadmill exercise test was only 33% (p<0.001). Furthermore, among the patients having significant coronary stenosis, the severity score was significantly elevated in patients who had electrocardiographic abnormal Q wave compared to those without abnormal Q wave (51.0±38.8 versus 20.0±12.1, p<0.05). These data suggest that the pharmacological stress scintigraphy using dipyridamole injection provides not only the accurate detection but quantitative evaluation of myocardial ischemia in these patients. This noninvasive technique may become one of the most useful index for detection and follow-up of myocardial ischemia in Kawasaki disease. (author)

  7. Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study

    International Nuclear Information System (INIS)

    Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D'Aragona Tagliavia, Irene; Casagranda, Mirta; Marzullo, Paolo; Cannizzaro, Giorgio; Giubbini, Raffaele; Bertagna, Francesco; Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina; Bertolaccini, Pietro; Bonini, Rita

    2011-01-01

    In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD). We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI > 27 were considered ''overweight''. Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data. In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p < 0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p <0.05). AC improved specificity in the evaluation of right CAD in overweight men. In the other evaluable subgroups specificity was not significantly affected while sensitivity was frequently reduced. (orig.)

  8. Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study

    Energy Technology Data Exchange (ETDEWEB)

    Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D' Aragona Tagliavia, Irene; Casagranda, Mirta; Marzullo, Paolo [Fondazione CNR-Regione Toscana ' ' G. Monasterio' ' , Nuclear Medicine, Pisa (Italy); Cannizzaro, Giorgio [A.O.V. Cervello, Nuclear Medicine, Palermo (Italy); Giubbini, Raffaele; Bertagna, Francesco [Spedali Civili, Nuclear Medicine, Brescia (Italy); Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina [Ospedale Maggiore, Nuclear Medicine, Bologna (Italy); Bertolaccini, Pietro; Bonini, Rita [Ospedale SS Giacomo e Cristoforo, Nuclear Medicine, Massa (Italy)

    2011-10-15

    In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD). We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI > 27 were considered ''overweight''. Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data. In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p < 0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p <0.05). AC improved specificity in the evaluation of right CAD in overweight men. In the other evaluable subgroups specificity was not significantly affected while sensitivity was frequently reduced. (orig.)

  9. Reproducibility of non-invasive measurement for left ventricular contractility using gated myocardial SPECT

    International Nuclear Information System (INIS)

    Kim, Kyeon Min; Lee, Dong Soo; Kim, Yu Kyeong; Cheon, Gi Jeong; Kim, Seok Ki; Chung, June Key; Lee, Myung Chul

    2001-01-01

    We tried to establish the reproducibility of the measurement of maximal elastance (Emax) and to compare the degree of the reproducibility of two estimation methods: single pressure-volume loop method and parameter optimization method. In 47 patients (42 males and 5 females, 53 ± 10 years old) with suspected coronary artery disease (ejection fraction; 22-68%), gated Tc-99m MIBI myocardial SPECT and arterial tonometry were acquired, In 11 patients among these 47 patients, gated SPECT and tonometry were performed twice consecutively with patients in situ. Emax and void volume (Vo) were estimated using single pressure-volume loop method of Lee and parameter optimization method based on linear approximation of Yoshizawa. Correlation between the consecutive measurements by each method and correlation between the two estimation methods were compared. Reproducibility of Emax (r=0.96) and Vo (r=0.99) by single pressure-volume method was better than the reporducibility of Emax (r=0.89) and Vo (r=0.64) by parameter optimization method. Correlations of Emax and Vo were fair between the two methods. The correlation of Emax (r=0.77) was better thn that of Vo (r=0.65). Reproducibiity of Emax measurement by single pressure-volume loop method using gated myocardial SPECT and arterial tonometry was excellent. Reproducibility by parameter optimization method was also but was less than that achieved by single pressure-volume method

  10. Quantitation of myocardial blood flow and myocardial flow reserve with {sup 99m}Tc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, MO (United States); Chen, Fu-Chung; Chen, Chien-Cheng [Show Chwan Memorial Hospital, Section of Cardiology, Department of Internal Medicine, Changhua (China); Wu, Tao-Cheng [Taipei Veterans General Hospital, Section of Cardiology, Department of Internal Medicine, Taipei (China); Huang, Wen-Sheng [Changhua Christian Hospital, Department of Medical Research and Department of Nuclear Medicine, Changhua (China); Hou, Po-Nien [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Central Taiwan University of Science and Technology, Department of Medical Imaging and Radiological Science, Taichung (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China)

    2014-12-15

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or <50 % stenosis). DySPECT and GSPECT scans were performed on a widely used dual-head SPECT/CT scanner. The DySPECT imaging protocol utilized 12-min multiple back-and-forth gantry rotations during injections of {sup 99m}Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a

  11. A comparative study of 99Tcm-tetrofosmin and 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Zhao Kui; Chen Peng; Zhang Furong; Shen Wenhua

    2001-01-01

    Objective: To evaluate the value of 99 Tc m -tetrofosmin myocardial imaging for detecting coronary artery disease. Methods: Twenty-seven patients underwent 99 Tc m -tetrofosmin SPECT, twenty-six patients underwent 99 Tc m -MIBI SPECT; coronary angiography was performed on patients included in both groups (≥50% luminal diameter stenosis was considered significant coronary stenosis). Results: 99 Tc m -tetrofosmin produced high quality myocardial images from 30 min to several hours postinjection, the outlines of myocardial perfusion images provided by 99 Tc m -tetrofosmin imaging were clearly discernible. One-day exercise/rest 99 Tc m -tetrofosmin myocardial perfusion imaging was feasible and had a high sensitivity for detection of coronary artery disease. Sensitivities of 99 Tc m -tetrofosmin SPECT and 99 Tc m -MIBI SPECT for detecting coronary artery disease were 90% and 94%, respectively. The 95% confidence limits of both sensitivities were 68.65% - 98.77% and 72.33% - 99.86%, respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 72.33% - 99.86% respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 66.38% - 98.70%, respectively; efficiencies of both imaging agents were 85.2% and 88.5%, respectively. The 95% confidence limits of both efficiencies were 65.81% - 95.78% and 69.44 - 98.70%, respectively. The specificity for both imaging agents was 71% and 75%. There was no significant difference among above results (P > 0.05). No ECG abnormalities were found following the injection of 99 Tc m -tetrofosmin SPECT. There were no drug-related effects on blood pressure, heart rate and body temperature. This experiment failed to provide the negative predictive value of the myocardial perfusion imaging with 99 Tc m -tetrofosmin because that few patients with

  12. [Anomalous origin of the left coronary artery from the pulmonary trunk with myocardial infarction and severe left ventricular dysfunction in infancy--assessment of myocardial damage using SPECT studies with 201TlCl and 123I-BMIPP].

    Science.gov (United States)

    Miyamoto, T; Horigome, H; Sato, H; Yamada, M; Inai, K; Takeda, T; Ishikawa, N; Hoshino, H; Itai, Y

    1996-02-01

    A 4-month-old male infant with Bland-White-Garland (BWG) syndrome complicated myocardial infarction was reported. Signs included tachypnea, coughing, and failure to thrive. However, there was no sign of myocardial infarction. A chest radiograph revealed cardiomegaly (CTR = 65%) and electrocardiogram showed abnormal Q waves in I, aVL, V6 leads. Cardiac catheterization and angiography revealed marked dilatation of left ventricle (end-diastolic volume = 384 ml/m2) and extremely depressed ejection fraction (16%), confirming the diagnosis of BWG syndrome. A 201TlCl-myocardial SPECT demonstrated apical defect and hypoperfusion in the anterolateral, inferoposterior walls, whereas 123I-beta-methyl-p-iodophenylpentadecanoic-acid (123I-BMIPP) SPECT showed a wider defect area. SPECT studies with 201TlCl and 123I-BMIPP, are useful to assess myocardial viability more accurately in BWG syndrome.

  13. The relation between angina and myocardial ischemia during exercise stress in coronary artery disease

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1988-01-01

    To examine the mechanism of occurrence of anginal chest pain from the aspect of myocardial ischemia, myocardial Tl-201 SPECT scans were obtained immediately and 3 hr after exercise (Ex) in 35 patients with coronary artery disease (CAD). The extent of ischemia was defined as the percentage of ischemic segments to the entire left ventricle. The minimum washout (WO) rate correlated well with the ratio of Tl uptake in the ischemic area to that in the normal area during Ex in the other 9 patients having single vessel CAD without previous history of myocardial infarction. This suggested that the miminum WO rate reflects the severity of Ex-induced ischemia. According to the development of angina during Ex, patients were classified as having either symptomatic ischemia (n = 16) or silent ischemia (n = 19). In regard to age, sex, a history of myocardial infarction, severity of CAD, and the extent of Ex-induced ischemia, there was no difference between the two groups. The minimum WO rate and the incidence of Ex-induced ST depression were significantly lower and higher, respectively, in the group with symptomatic ischemia than that with silent ischemia. The severity of Ex-induced ischemia has important implications for the development of anginal chest pain. (Namekawa, K.)

  14. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    International Nuclear Information System (INIS)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-01-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease

  15. Functional assessment of the right ventricle with gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Abbati, D.; Carolan, M.

    2002-01-01

    Full text: Evaluation of right ventricular function can provide valuable information in a variety of cardiac and non-cardiac conditions. Functional assessment of the right ventricle is difficult owing to its anatomy and geometry. We describe a method of assessing right ventricular function using gated myocardial perfusion SPECT. In 20 patients right and left ventricular ejection fractions (RVEF, LVEF) were determined using gated blood pool (GBPS) and gated myocardial perfusion SPECT (GSPECT). To avoid contamination with right atrial activity the two frame method was adopted for gated blood pool data when measuring RVEF. In 9 patients with normal right ventricles, an index of wall thickening for the right ventricle was derived from the peak systolic and diastolic counts in the free wall. There was good linear correlation between the two methods adopted for calculation of LVEF and RVEF. Bland - Airman analysis demonstrated good agreement between the two methods with no specific bias. The mean LVEF was 47.9 +/-12% (GBPS) and 47.3 +/- 12.4 (GSPECT). The mean RVEF was 43.2 +/- 9.6% (GBPS) and 44.2 +/- 8.5% (GSPECT). In both cases the values were significantly different. The mean wall motion index was 35%. There was no correlation between the wall thickness index and ejection fraction however the index was greater in patients with normal right ventricle than in those with reduced RVER Gated SPECT offers an alternative to GBPS for the functional assessment of the right ventricle. Utilising GSPECT will allow the simultaneous assessment of both the right and left ventricles. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  16. Prognostic study of risk stratification among Japanese patients with ischemic heart disease using gated myocardial perfusion SPECT: J-ACCESS study

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Nakajima, Kenichi; Kusuoka, Hideo; Yamashina, Akira; Nishimura, Shigeyuki

    2008-01-01

    Although the prognostic value of myocardial perfusion imaging using gated single photon emission computed tomography (SPECT) for predicting major cardiac events has been evaluated, little is known about the relevance of this procedure to the Japanese population. A total of 4,031 consecutive Japanese patients with suspected or confirmed ischemic heart diseases were registered at 117 hospitals in the Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT investigation. Gated stress/rest myocardial perfusion SPECT was performed and the patients were followed up for 3 years. Segmental perfusion scores and quantitative gated SPECT results were calculated. Major cardiac events were defined as cardiac death, nonfatal myocardial infarction, and severe heart failure. During the 3-year follow-up, cardiac death (n = 57) and nonfatal myocardial infarction (n = 39) occurred in 96 patients (2.4%/3 years) when hard events were the endpoints. When severe heart failure was included as an endpoint, major cardiac events that developed in 175 patients (4.3%/3 years) comprised cardiac death (n = 45), nonfatal myocardial infarction (n = 37), and severe heart failure (n = 93). Normal and severely abnormal summed stress score values were associated with low (2.31%/3 years) and high (9.21%/3 years) rates of major cardiac events, respectively. Rates of major cardiac events were significantly higher in patients with ejection fraction (EF) <45% than in those with EF 45% or higher (16.55 vs 2.94%/3 years; P < 0.001). The incidence of major cardiac events within 3 years was also significantly higher among patients with high end-systolic volumes. The major event rates were similar among nondiabetic patients with and diabetic patients without prior myocardial infarction at 5.06% and 5.73%/3 years, respectively. Cardiac event rates were significantly lower in the Japanese than in the USA and European populations. However, large myocardial perfusion defects and

  17. Quantification of left ventricular function by gated myocardial perfusion SPECT using multidimTM

    International Nuclear Information System (INIS)

    Huang Jin; Song Wenzhong; Chen Mingxi

    2004-01-01

    Objective: To evaluate the accuracy of left ventricular function by gated SPECT using the software Multidim TM . Methods: Rest gated SPECT was performed on 42 cases involved 26 normal subjects and 16 patients with myocardial infarct (MI). All cases underwent rest equilibrium radionuclide angiocardiography (ERNA) within 1 w. Results: (1)End diastolic volume (EDV), end systolic volume (ESV) and left ventricular ejection fraction(LVEF)were calculated using the software MultidimtMand ERNA. The correlation coefficient between the two Methods was 0.90,0.89,0.92 respectively(P TM , but the EDV and ESV value measured by this software maybe high with small heart. (authors)

  18. Tl-201 myocardial SPECT in patients with Duchenne's muscular dystrophy: A long-term follow-up

    International Nuclear Information System (INIS)

    Nagamachi, S.; Jinnouchi, S.; Ono, S.; Hoshi, H.; Inoue, K.; Watanabe, K.

    1989-01-01

    Tl-201 SPECT was used to evaluate myocardial involvement in 13 patients with Duchenne's muscular dystrophy. Serial studies of 9 patients were done at two-year intervals. The hypoperfused areas of the left ventricle became more prominent with age and severity

  19. Improved exercise myocardial perfusion during lidoflazine therapy

    International Nuclear Information System (INIS)

    Shapiro, W.; Narahara, K.A.; Park, J.

    1983-01-01

    Lidoflazine is a synthetic drug with calcium-channel blocking effects. In a study of 6 patients with severe classic angina pectoris, single-blind administration of lidoflazine was associated with improved myocardial perfusion during exercise as determined by thallium-201 stress scintigraphy. These studies demonstrate that lidoflazine therapy is associated with relief of angina, an increased physical work capacity, and improved regional myocardial perfusion during exercise

  20. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    International Nuclear Information System (INIS)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; Bondt, Pieter De; Buechel, Ronny R.; Kaufmann, Philip A.; Cuocolo, Alberto; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J.H.A.; Slart, Riemer H.J.A.; Traegaardh, Elin; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015 0 7 E ANM F INAL myocardial p erfusion g uideline.pdf. (orig.)

  1. Improvement of myocardial perfusion status in response to indian vedic breathing

    International Nuclear Information System (INIS)

    Anand, Y.N.I.; Muthu, G.S.

    2004-01-01

    Introduction: Yoga is the buzz word all over the world today. Amidst their busy schedule, people tend to ignore their personal health. Management of various disorders, especially those involving interventions, surgical or radiological, is very expensive. The Indian Vedic Exercises, of which Pranaayaama is one, emphasize on prevention of the diseases in order to keep the individual in good health. It is equally applicable to those who have already suffered from various disorders and in whom both improvement and/or avoidance of further deterioration are required. However, no Objective assessment of the disease status in response to these exercises has been reported so far. Objectives: This pilot study has been undertaken on patients with reversible myocardial perfusion defects to Objectively monitor the improvements in the myocardial perfusion in response to a breathing exercise, Pranayama, a breathing technique prescribed in the Indian Vedic Sciences. Methods: Two patients who were found to have reversible myocardial perfusion defects were taken up in this study. These defects were diagnosed from the myocardial perfusion SPECT done in stressed (on Tread Mill) and resting states with 99m Technetium labeled MIBI.These patients were taught the pranayama technique which is done for about 30 minutes every day. At the end of four months from the commencement of this technique, the myocardial perfusion SPECT studies were repeated. Details of the exercise in the form of a CD are available on request. Results: Overall good improvements were observed in all the quantitative parameters in the TMT and SPECT studies in the studies done after the pranayama procedures in both the patients. Perfusion defects seen in the stress images of the initial studies have almost completely reversed in the stress images of the later study. Patients are asymptomatic and are leading a comfortable life. Conclusion: This is only a study of two cases to Objectively evaluate the effects of pranayama

  2. Exercise-induced ST-segment depression and myocardial ischemia in patients with hypertrophic cardiomyopathy. Myocardial scintigraphic study

    International Nuclear Information System (INIS)

    Miyai, Nobuyuki; Kawasaki, Tatsuya; Taniguchi, Takuya; Kamitani, Tadaaki; Kawasaki, Shingo; Sugihara, Hiroki

    2005-01-01

    Patients with hypertrophic cardiomyopathy (HCM) sometimes develop myocardial ischemia during exercise in the absence of coronary lesions. The relationship between myocardial ischemia and ST-segment depression was investigated during exercise testing in patients with HCM. Regional hypoperfusion and/or transient left ventricular cavity dilation, a parameter of subendocardial hypoperfusion, were assessed on exercise 99 m Tc-tetrofosmin myocardial scintigraphy in 42 patients with non-obstructive HCM. The scintigraphic results were further correlated with the ST-segment responses to exercise. Regional hypoperfusion or transient left ventricular cavity dilation were observed in 19 (45%) or 16 (38%) patients with HCM, respectively. The incidence of ST-segment depression ≥0.1 mV during exercise testing was similar in HCM patients with regional hypoperfusion, with transient left ventricular cavity dilation, and without hypoperfusion (42%, 38%, 38%, p=0.95). Furthermore, exercise-induced ST-segment depression ≥0.1 mV occurred similarly irrespective of symptoms, exercise tolerance, the degree or the site of hypertrophy, or the presence or absence of resting ST-segment depression. ST-segment depression during exercise testing was common in patients with HCM, but seems to be an unreliable marker of myocardial ischemia as assessed by exercise scintigraphy. (author)

  3. [Influence of the professional experience of the clinical cardiologist on the adequacy of the clinical indications of myocardial perfusion gated-SPECT].

    Science.gov (United States)

    Dominguez-Rodriguez, Alberto; Avanzas, Pablo; Abreu-Gonzalez, Pedro; Sanchez Grande-Flecha, Alejandro; García-Baute, María Del Carmen; Gómez, María Ángeles

    2017-11-30

    During cardiology training, the cardiology fellow has to be trained in all things related to the indication, interpretation, and performing of nuclear cardiology studies using single photon emission computed tomography (SPECT). The aim of the present study was to analyse the relationship between the adequacy of indications of myocardial perfusion gated-SPECT and the years of experience since the completion of cardiology training. A descriptive, retrospective analysis was performed on a single-centre register, in which the indications (adequate or inadequate use) were recorded according to myocardial perfusion gated-SPECT guidelines, prescribed by cardiologists of a university hospital. A total of 950 gated-SPECT tests were analysed according to the appropriate or inadequate indication. The sample of study was distributed in quartiles (years) since the cardiologist finished the residency. Cardiologists with less than 10 years of clinical experience reported a higher proportion of gated-SPECT tests compared to the more experienced cardiologists (87.6 vs. 9.3%, P<.001). After adjusting for age, gender, and cardiovascular risk factors, the multivariate analysis showed that, for each year of experience after completion of cardiology training, the probability of adequately indicating the test (OR: 1.33, 95% CI: 1.29-1.38, P<.001) was statistically significant. The professional experience of the clinical cardiologist is the most important factor to perform an appropriate indication of gated-SPECT myocardial perfusion. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  4. Preliminary study of left ventricular cavity-to-myocardial count ratio. A new parameter for left ventricular function

    International Nuclear Information System (INIS)

    Zhou Ying; Qu Wanying; Zhu Ming; Gao Wenping; Zhao Hongshan

    1995-01-01

    A new simple quantitative parameter, left ventricular cavity-to-myocardial count ratio (C/M ratio) was suggested and compared with LVEF to assess its reliability and clinical value. Of 220 patients in the study, 102 had both exercise 99m Tc-MIBI myocardial SPECT imaging and resting radionuclide ventriculography, another 118 patients had both rest 99m Tc-MIBI myocardial SPECT imaging and rest radionuclide ventriculography, 740 MBq of 99m Tc-MIBI was injected intravenously. Both the exercise and rest C/M ratio were determined on short-axis tomograms and LVEF were calculated from radionuclide ventriculography. The correlation between LVEF and the C/M (exercise and rest) was analyzed. There was a positive linear correlation between LVEF measured by ventriculography and both C/M exercise ratio (r = 0.6964) and C/M rest ratio (r = 0.6995). The sensitivity of C/M exercise and rest ratio for detecting patients with left ventricular dysfunction is 71.9%, 68.6%; the specificity is 92.9%, 97.0%; the accuracy is 86.3%, 84.7% respectively. C/M ratio can accurately identify patients with CAD who have resting left ventricular dysfunction. It was highly reproducible, reliable and useful in clinical diagnosis

  5. Reproducibility of an automatic quantitation of regional myocardial wall motion and systolic thickening on gated Tc-99m-MIBI myocardial SPECT

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lee, Dong Soo; Cheon, Gi Jeong; Kim, Yu Kyeong; Chung, June Key; Lee, Myung Chul

    2000-01-01

    The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction 51±14%) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using AutoQUANT TM software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Segmental wall motion and systolic thickening quantified using AutoQUANT TM software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening

  6. Absolute quantitation of myocardial blood flow with {sup 201}Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Hidehiro; Kim, Kyeong-Min; Nakazawa, Mayumi; Sohlberg, Antti; Zeniya, Tsutomu; Hayashi, Takuya; Watabe, Hiroshi [National Cardiovascular Center Research Institute, Department of Investigative Radiology, Suita City, Osaka (Japan); Eberl, Stefan [National Cardiovascular Center Research Institute, Department of Investigative Radiology, Suita City, Osaka (Japan); Royal Prince Alfred Hospital, PET and Nuclear Medicine Department, Camperdown, NSW (Australia); Tamura, Yoshikazu [Akita Kumiai General Hospital, Department of Cardiology, Akita City (Japan); Ono, Yukihiko [Akita Research Institute of Brain, Akita City (Japan)

    2008-05-15

    {sup 201}Tl has been extensively used for myocardial perfusion and viability assessment. Unlike {sup 99m}Tc-labelled agents, such as {sup 99m}Tc-sestamibi and {sup 99m}Tc-tetrofosmine, the regional concentration of {sup 201}Tl varies with time. This study is intended to validate a kinetic modelling approach for in vivo quantitative estimation of regional myocardial blood flow (MBF) and volume of distribution of {sup 201}Tl using dynamic SPECT. Dynamic SPECT was carried out on 20 normal canines after the intravenous administration of {sup 201}Tl using a commercial SPECT system. Seven animals were studied at rest, nine during adenosine infusion, and four after beta-blocker administration. Quantitative images were reconstructed with a previously validated technique, employing OS-EM with attenuation-correction, and transmission-dependent convolution subtraction scatter correction. Measured regional time-activity curves in myocardial segments were fitted to two- and three-compartment models. Regional MBF was defined as the influx rate constant (K{sub 1}) with corrections for the partial volume effect, haematocrit and limited first-pass extraction fraction, and was compared with that determined from radio-labelled microspheres experiments. Regional time-activity curves responded well to pharmacological stress. Quantitative MBF values were higher with adenosine and decreased after beta-blocker compared to a resting condition. MBFs obtained with SPECT (MBF{sub SPECT}) correlated well with the MBF values obtained by the radio-labelled microspheres (MBF{sub MS}) (MBF{sub SPECT} = -0.067 + 1.042 x MBF{sub MS}, p < 0.001). The three-compartment model provided better fit than the two-compartment model, but the difference in MBF values between the two methods was small and could be accounted for with a simple linear regression. Absolute quantitation of regional MBF, for a wide physiological flow range, appears to be feasible using {sup 201}Tl and dynamic SPECT. (orig.)

  7. Predictive values of early rest/24 hour delay Tl-201 perfusion SPECT for wall motion improvement in patients with acute myocardial infarction after reperfusion

    International Nuclear Information System (INIS)

    Hyun, In Young; Kwan, June

    1998-01-01

    We studied early rest/24 hour delay Tl-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Among 17 patients (male/female=11/6, age: 59±13) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay:11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest Tl-201 perfusion SPECT less then 6 hours after reperfusion and delay Tl-201 perfusion SPECT next day. Tl-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest Tl-201 uptake ≤2 or combination of rest Tl-201 uptake ≤2 or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ≥1 grade in follow up echo compared with the baseline values. Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest Tl-201uptake were 99%, and 54%.PPV and NPV of rest Tl-201 uptake were 100% and 52% respectively. Predictive values of comibination of rest Tl-201 uptake and late reversibility were not significantly different compared with predictive values of rest Tl-201 uptake only. We conclude that early Tl-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative

  8. Results of myocardial SPECT with fatty acids in coronary artery disease

    International Nuclear Information System (INIS)

    Reske, S.N.; Kropp, J.; Reichmann, K.; Winkler, C.; Knapp, F.F.; Nitsch, J.

    1986-01-01

    New developments in radiopharmacology of 123 I-labeled metabolic tracers and single-photon emission computerized tomography (SPECT) allow now-a-days the assessment of parameters of cardiac energy metabolism in well-defined areas of the heart muscle. This article will present a brief outline of the basic pathophysiological principles used in the application of 123 I-labeled phenyl fatty acids for the evaluation of CAD. First clinical results suggest an important application of cardiac fatty acid metabolic imaging to the detection, localisation and conceivable quantitation of myocardial ischemia, myocardial infarction and assessment of tissue viability. In addition to the diagnostic applications in CAD, cardiac fatty acid metabolic imaging may provide new perspectives to pathophysiological investigations of the coupling of local flow and substrate utilisation in vivo and the effect of therapeutic interventions. (orig.) [de

  9. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  10. DIAGNOSTIC VALUE of Tc-99m TETROFOSMİN GATED SPECT IN MYOCARDIAL VIABILITY INVESTIGATION AFTER ADMINISTRATION TRIMETAZIDINE and NITRATE IN THE PATIENTS WITH MYOCARDIAL INFARCTION

    OpenAIRE

    TURHAL, Özgül; TUTUŞ, Ahmet; KULA, Mustafa

    2018-01-01

    ABSTRACT Aim: With the aim of investigating of the myocardial viability on the patients with MI, the results obtained from Tc-99m-tetrofosmin gated SPECT following the nitrate infusion and acute TMZ were compared.Method: For this study, 30 patients who had MI and were be planned of revascularization process were taken. The patients were applied Tc-99m-tetrofosmin gated SPECT basally and following nitrate infusion and acute TMZ separately each day. The data from perfusion were quantitatively e...

  11. Impairment of myocardial perfusion in children with sickle cell disease

    International Nuclear Information System (INIS)

    Maunoury, C.; Acar, P.; Montalembert, M. de

    2003-01-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 ± 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 ± 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  12. A new method for quantification of pulmonary thallium uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Mannting, F.

    1990-01-01

    Quantified pulmonary thallium 201 (Tl) uptake was assessed in 32 normal people and 66 patients with suspected coronary artery disease (CAD) by a new method utilizing SPECT acquisition data. In 26 subjects pulmonary uptake was assessed with both SPECT and planar techniques. Pulmonary/myocardial (PM) ratios for the whole right lung (PM1) and for the upper left lung (PM2) were computed and compared with stress test, coronary angiography, radionuclide angiography (ERNA), and quantified Tl SPECT results. Excellent correlation between pulmonary uptake assessed by planar and SPECT technique was disclosed (r=0.92). The PM ratio (PM1/PM2) sensitivity and specificity in patients with CAD was 88%/92% and 60%/70%, for predicting perfusion abnormalities 90%/87% and 88%/88%, and an inverse correlation to LVEF was found (r=-0.40/r=-0.37, P<0.01). Significant correlations to coronary angiography findings (r=0.54/r=0.49, P<0.001) and to number of vessel territories with abnormal perfusion (r=0.70/r=0.69, P<0.001) were seen. Thus, pulmonary Tl uptake can be assessed in SPECT studies. The new method's discriminative ability seems higher than that of the standard planar technique currently employed. Positive correlations to coronary angiography findings and even stronger ones to perfusion abnormalities were observed. (orig.)

  13. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    Energy Technology Data Exchange (ETDEWEB)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de [University of Amsterdam, Department of Nuclear Medicine, F2-238, Academic Medical Center, Amsterdam (Netherlands); Acampa, Wanda [National Council of Research, Institute of Biostructures and Bioimaging, Naples (Italy); Anagnostopoulos, Constantinos [Academy of Athens, Center for Experimental Surgery, Clinical and Translational Research, Biomedical Research Foundation, Athens (Greece); Ballinger, Jim [Guy' s Hospital - Guy' s and St Thomas' Trust Foundation, Department of Nuclear Medicine, London (United Kingdom); Bengel, Frank [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Bondt, Pieter De [OLV Hospital, Department of Nuclear Medicine, Aalst (Belgium); Buechel, Ronny R.; Kaufmann, Philip A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Flotats, Albert [Universitat Autonoma de Barcelona, Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain); Hacker, Marcus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Hindorf, Cecilia [Skaane University Hospital, Department of Radiation Physics, Lund (Sweden); Lindner, Oliver [University Hospital of the Ruhr-University Bochum, Heart and Diabetes Center North Rhine-Westphalia, Institute for Radiology, Nuclear Medicine and Molecular Imaging, Bad Oeynhausen (Germany); Ljungberg, Michael [Lund University, Department of Medical Radiation Physics, Lund (Sweden); Lonsdale, Markus [Bispebjerg Hospital, Department of Clinical Physiology and Nuclear Medicine, Copenhagen (Denmark); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Service Commun Investigations chez l' Homme, GIP Cyceron, Caen (France); Minarik, David [Skaane University Hospital, Radiation Physics, Malmoe (Sweden); Scholte, Arthur J.H.A. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Slart, Riemer H.J.A. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Traegaardh, Elin [Skaane University Hospital and Lund University, Clinical Physiology and Nuclear Medicine, Malmoe (Sweden); Hesse, Birger [University Hospital of Copenhagen, Department of Clinical Physiology and Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark)

    2015-11-15

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015{sub 0}7{sub E}ANM{sub F}INAL myocardial{sub p}erfusion{sub g}uideline.pdf. (orig.)

  14. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  15. Prognostic value of normal exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Lin Jinghui; Zhu Mei; Wu Shuyan

    1996-01-01

    To assess the prognostic implications, patients with a normal exercise myocardial imaging were followed up. 54 patients underwent exercise myocardial perfusion imaging and exercise ECG test. The images of all of them were normal. Coronary arteriography was performed in 50 patients. Among them 4 patients had single vessel lesion. Follow-up period of all the patients was >1 year (12∼90 Mo.). Likelihood of coronary artery disease (CAD, CAD LK) was estimated before and after test by Bayesian analysis. Mean of the pretest CAD LK was 19% and after test decreased to 13%. The difference between the CAD LK pre- and after test was significant (U = 6.0198, P<0.01). During the follow-up period cardiac event (CE) occurred in only one patient. The CE rate was 0.2% per year. No CE occurred in the 4 patients with CAD and in the 55 patients with positive exercise ECG. The data confirm that a normal stress myocardial imaging predicts an excellent prognosis even in patients with CAD or a high pretest CAD LK or a positive exercise ECG

  16. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  17. Intravenous streptokinase therapy in acute myocardial infarction: Assessment of therapy effects by quantitative 201Tl myocardial imaging (including SPECT) and radionuclide ventriculography

    International Nuclear Information System (INIS)

    Koehn, H.; Bialonczyk, C.; Mostbeck, A.; Frohner, K.; Unger, G.; Steinbach, K.

    1984-01-01

    To evaluate a potential beneficial effect of systemic streptokinase therapy in acute myocardial infarction, 36 patients treated with streptokinase intravenously were assessed by radionuclide ventriculography and quantitative 201 Tl myocardial imaging (including SPECT) in comparison with 18 conventionally treated patients. Patients after thrombolysis had significantly higher EF, PFR, and PER as well as fewer wall motion abnormalities compared with controls. These differences were also observed in the subset of patients with anterior wall infarction (AMI), but not in patients with inferior wall infarction (IMI). Quantitative 201 Tl imaging demonstrated significantly smaller percent myocardial defects and fewer pathological stress segments in patients with thrombolysis compared with controls. The same differences were also found in both AMI and IMI patients. Our data suggest a favorable effect of intravenous streptokinase on recovery of left ventricular function and myocardial salvage. Radionuclide ventriculography and quantitative 201 Tl myocardial imaging seem to be reliable tools for objective assessment of therapy effects. (orig.)

  18. Comparative value of brain perfusion SPECT and [123I]MIBG myocardial scintigraphy in distinguishing between dementia with Lewy bodies and Alzheimer's disease

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Iwamoto, Toshihiko; Chikamori, Taishiro; Usui, Yasuhiro; Yamashina, Akira; Koizumi, Kiyoshi; Abe, Kimihiko

    2006-01-01

    Both decreased occipital perfusion on brain single-photon emission computed tomography (SPECT) and reduction in cardiac 123 I-metaiodobenzylguanidine (MIBG) uptake are characteristic features of dementia with Lewy bodies (DLB), and potentially support the clinical diagnosis of DLB. The aim of this study was to compare the diagnostic value of these two methods for differentiation of DLB from Alzheimer's disease (AD). The study population comprised 19 patients with probable DLB and 39 patients with probable AD who underwent both SPECT with N-isopropyl-p-[ 123 I]iodoamphetamine and MIBG myocardial scintigraphy. Objective and quantitative measurement of perfusion in the medial occipital lobe, including the cuneus and lingual gyrus, was performed by the use of three-dimensional stereotactic surface projections. Medial occipital perfusion was significantly decreased in the DLB group compared with the AD group. The mean heart/mediastinum ratios of MIBG uptake were significantly lower in the DLB group than in the AD group. Although SPECT failed to demonstrate significant hypoperfusion in the medial occipital lobe in five patients with DLB, marked reduction of MIBG uptake was found in all patients with DLB. Receiver operating characteristic analysis revealed that MIBG myocardial scintigraphy enabled more accurate discrimination between DLB and AD than was possible with perfusion SPECT. MIBG myocardial scintigraphy may improve the sensitivity in the detection of DLB. In particular, this method may provide a powerful differential diagnostic tool when it is difficult to distinguish cases of DLB from AD using brain perfusion SPECT. (orig.)

  19. Evaluation of left ventricular ejection fraction using quantitative gated SPECT (QGS)

    International Nuclear Information System (INIS)

    Musa, M. A. A.

    2010-07-01

    Electrocardiographic ally gated myocardial perfusion SPECT (G SPECT) is a state-of the art technique for the combined evaluation of myocardial perfusion and left ventricular function within a single study. It is currently one of the most commonly performed cardiology procedures in a nuclear medicine department. Automation of the image processing and quantification has made this techniques highly reproducible, practical and user friendly in the clinical setting . In patients with coronary artery disease, gating enhances the diagnostic and prognostic capability of myocardial perfusion imaging provides incremental information over the the perfusion data, and has shown potentials for myocardial viability assessment and sequential follow-up after therapy. Evaluation of the left ventricular (L V) function is important in clinical cardiology. Quantifying the degree and extent of the L V functional abnormalities permits a systematic assessment of the disease process on the myocardial performance. The aim of this thesis is to evaluate left ventricular ejection fraction (LVEF) in patients with no evidence of ischemic response during the stress test. This investigation was carried out in view of the few reports concerning the findings ventricular function with gated SPECT in these situations in the normal population, which is relevant when considering the possibility of myocardial stunning. Method: We prospectively studied 30 selected patients, in difference age and gender. A one-day protocol was used, with injection 555 MBq - 1.11 MBq (15 - 30 mCi) of 99 mTc-M1 B1 at stress and rest. Gated perfusion SPECT was acquired 30 to 60 minutes after radiotracer injection in both condition and processed using QGSPECT software. Difference between stress and rest LVEF was calculated. Result and conclusion: rest LVEF was higher in the stress (exercise) group, A trend line was done in both groups and r-value was (0.9) and p=0.04 in acceptance value. Standard deviation of LVEF also was

  20. Relationships between the lung-heart ratio assessed from post-exercise thallium-201 myocardial tomograms, myocardial ischemia and the extent of coronary artery disease

    International Nuclear Information System (INIS)

    Ilmer, B.; Reijs, A.E.; Reiber, J.H.; Bakker, W.; Fioretti, P.

    1990-01-01

    Uptake of thallium (Tl)-201 in the lungs has been proposed as a measure of left ventricular dysfunction. In this study we were interested in pursuing two goals: (1) to assess possible relationships between the post-exercise Tl-201 lung-heart (LH)-ratio determined from the anterior view during SPECT-acquisition, myocardial ischemia and the extent of coronary artery disease; and (2) to explore the effects of coronary revascularisation procedures on the LH-ratio. The study group consisted of 145 patients with early and late postexercise Tl-201 tomograms, including 32 PTCA-patients with pre- and post-PTCA studies and 20 patients who underwent coronary artery bypass surgery (CABG) with corresponding pre- and post-CABG studies. Ischemia was defined as evoked angina during the exercise test in combination with greater than or equal to 1 mm horizontal or downsloping ST-depression on the ECG. The severity of coronary obstructions was assessed from coronary angiograms with a PC-based digital caliper technique; a stenosis was defined to be significant when its severity exceeded 50% diameter stenosis. The LH-ratio was defined by the ratio of the mean pulmonary counts and the mean myocardial counts assessed from corresponding regions of interest (ROI's) positioned over the left lung and the heart, respectively in the anterior view of a tomographic data acquisition procedure. Our results made clear that the LH-ratio was not significantly different between patients with and without ischemia during exercise, and between patients with single vs. multiple vessel disease

  1. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    Directory of Open Access Journals (Sweden)

    Sundaram P

    2009-01-01

    Full Text Available Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event-free survival in adults with ischemic heart disease. This article highlights various myocardial perfusion imaging (MPIradiopharmaceuticals, exercise procedures, pharmacological stress protocols, indications for MPI and myocardial perfusion patterns in children with some of the common congenital and acquired heart diseases.

  2. Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction

    International Nuclear Information System (INIS)

    Park, Soon Ah; Kim, Dae Weung; Kim, Chang Guhn; Jeong, Jin Won; Kim, Nam Ho; Yun, Kyeong Ho

    2009-01-01

    This study was performed to investigate the clinical significance of reverse redistribution (RR) phenomenon detected on delayed Tc-99m tetrofosmin myocardial single photon emission computed tomography (SPECT) in patients with acute myocardial infarction after revascularization. A Tc-99m tetrofrosmin myocardial SPECT was performed in 67 consecutive patients after revascularization for acute myocardial infarction. Myocardial SPECT imaging was performed for early imaging at 40 min and for delayed imaging at 180 min after reinjection at myocardial stress. Regional myocardial uptakes were scored by 4-point scoring in the left ventricular wall divided into 17 segments. Reverse redistribution was defined as an increase of more than 2 point in the activity score on the delayed image. Follow-up myocardial SPECT and coronary angiography (CAG) were performed 9 months later. On myocardial SPECT performed following revascularization, RR was observed in 100 of all 319 segments (31%) and in 43 patients (64%). The abnormalities of perfusion and regional wall motion were more severe in the patients with RR compared to those without RR (p<0.05). On follow-up myocardial SPECT, the myocardial perfusion, regional wall motion, and myocardial thickness were significantly improved in the patients with RR (p<0.05) however, these changes were not significant in those without RR. There was no significant difference between the patients with RR and those without RR in the occurrence of restenosis on CAG. In patients with acute myocardial infarction, the regions showing the RR phenomenon on delayed Tc-99m tetrofosmin SPECT may reflect viable myocardium and indicate recovery of salvaged myocardium

  3. Benefits of lifelong exercise training on left ventricular function after myocardial infarction.

    Science.gov (United States)

    Maessen, Martijn Fh; Eijsvogels, Thijs Mh; Stevens, Guus; van Dijk, Arie Pj; Hopman, Maria Te

    2017-11-01

    Background Endurance exercise training induces cardio-protective effects, but athletes are not exempted from a myocardial infarction. Evidence from animal studies suggests that exercise training attenuates pathological left ventricular remodelling following myocardial infarction. We tested the hypothesis that lifelong exercise training is related to attenuated pathological left ventricular remodelling after myocardial infarction as evidenced by better left ventricular systolic function in veteran athletes compared to sedentary peers. Design This was a cross-sectional study. Methods Sixty-five males (60 ± 6 years) were included and allocated to four groups based on lifelong exercise training volumes: (a) athletes ( n = 18), (b) post-myocardial infarction athletes (athletes + myocardial infarction, n = 20), (c) sedentary controls ( n = 13), and (d) post-myocardial infarction controls (sedentary controls + myocardial infarction, n = 14). Athletes were lifelong (≥20 years) highly physically active (≥30 metabolic equivalent of task (MET)-h/week), whereas sedentary controls did not meet the exercise guidelines (creatine-kinase, creatinine, aspartate transaminase and lactate dehydrogenase) following myocardial infarction and infarct location did not differ between athletes + myocardial infarction and sedentary controls + myocardial infarction. Left ventricular ejection fraction was significantly higher in athletes (61% ± 4), athletes + myocardial infarction (58% ± 4) and sedentary controls (57% ± 6) compared to sedentary controls + myocardial infarction (51% ± 7; p athletes (-19% (-21% to -17%), athletes + myocardial infarction (-16% (-20% to -12%)), and sedentary controls (-15% (-18% to -14%) compared to sedentary controls + myocardial infarction (-13% (-15% to -8%), p athletes.

  4. Characteristics of images of angiographically proven normal coronary arteries acquired by adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT with CT attenuation correction changed stepwise.

    Science.gov (United States)

    Takahashi, Teruyuki; Tanaka, Haruki; Kozono, Nami; Tanakamaru, Yoshiki; Idei, Naomi; Ohashi, Norihiko; Ohtsubo, Hideki; Okada, Takenori; Yasunobu, Yuji; Kaseda, Shunichi

    2015-04-01

    Although several studies have shown the diagnostic and prognostic value of CT-based attenuation correction (AC) of single photon emission computed tomography (SPECT) images for diagnosing coronary artery disease (CAD), this issue remains a matter of debate. To clarify the characteristics of CT-AC SPECT images that might potentially improve diagnostic performance, we analyzed images acquired using adenosine-stress thallium-201 myocardial perfusion SPECT/CT equipped with IQ[Symbol: see text]SPECT (SPECT/CT-IQ[Symbol: see text]SPECT) from patients with angiographically proven normal coronary arteries after changing the CT attenuation correction (CT-AC) in a stepwise manner. We enrolled 72 patients (Male 36, Female 36) with normal coronary arteries according to findings of invasive coronary angiography or CT-angiography within three months after a SPECT/CT study. Projection images were reconstructed at CT-AC values of (-), 40, 60, 80 and 100 % using a CT number conversion program according to our definition and analyzed using polar maps according to sex. CT attenuation corrected segments were located from the mid- and apical-inferior spread through the mid- and apical-septal regions and finally to the basal-anterior and basal- and mid-lateral regions in males, and from the mid-inferior region through the mid-septal and mid-anterior, and mid-lateral regions in females as the CT-AC values increased. Segments with maximal mean counts shifted from the apical-anterior to mid-anterolateral region under both stress and rest conditions in males, whereas such segments shifted from the apical-septal to the mid-anteroseptal region under both stress and rest conditions in females. We clarified which part of the myocardium and to which degree CT-AC affects it in adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT images by changing the CT-AC value stepwise. We also identified sex-specific shifts of segments with maximal mean counts that changed as

  5. Evaluation of myocardial disorders in patients with dilated cardiomyopathy and left ventricular eccentric hypertrophy; By sup 201 Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Junichi; Ohsawa, Hidefumi; Uchi, Takashi (Toho Univ., Tokyo (Japan). School of Medicine) (and others)

    1992-03-01

    {sup 201}Tl myocardial SPECT was performed in cases of dilated cardiomyopathy and valvular heart disease with left ventricular eccentric hypertrophy, and the two groups were compared from the standpoint of the mechanism of onset of myocardial disorders. Significant coefficients of correlation were seen between the Tl score and LVDd (r=0.792, r=0.785) and Tl score and LVEF (r=-0.634, r=-0.555) in both dilated cardiomyopathy and valvular heart disease. In cases of valvular heart disease, significant correlation coefficients (r=-0.756, r=-0.720) between LVDd and r-WR (relative-washout rate), and Tl score and r-WR were observed, but no such correlation was seen in dilated cardiomyopathy. In valvular heart disease, a decrease in myocardial perfusion associated with enlargement of the left ventricle appeared, while in dilated cardiomyopathy, there was a marked decrease in LVEF in proportion to the thallium defect. Therefore, it was assumed that left ventricular wall disorders occur due to myocardial metabolic disorders and coronary microcirculation disorders. (author).

  6. Stress-induced myocardial ischemia is associated with early post-stress left ventricular mechanical dyssynchrony as assessed by phase analysis of {sup 201}Tl gated SPECT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Cheng; Shen, Thau-Yun [Show Chwan Memorial Hospital, Department of Cardiology, Changhua (China); Chang, Ming-Che [Changhua Christian Hospital, Department of Nuclear Medicine, Changhua (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Wan-Chen [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Kao, Chia-Hung [China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-12-15

    In {sup 201}Tl SPECT myocardial perfusion imaging (MPI) data are acquired shortly after the stress injection to assess early post-stress left ventricle (LV) function. The purpose of this study was to use {sup 201}Tl SPECT MPI to investigate whether stress-induced myocardial ischemia is associated with LV mechanical dyssynchrony. Enrolled in the study were 75 patients who were referred for dipyridamole stress and rest {sup 201}Tl gated SPECT MPI. The early post-stress scan was started 5 min after injection, and followed by the rest scan 4 h later. The patients were divided into three groups: ischemia group (N = 25, summed stress score, SSS, {>=}5, summed rest score, SRS, <5), infarct group (N = 16, SSS {>=}5, SRS {>=}5) and normal group (N = 34, SSS <5, SRS <5). LV dyssynchrony parameters were calculated by phase analysis, and compared between the stress and rest images. In the ischemia group, LV dyssynchrony was significantly larger during stress than during rest. On the contrary, LV dyssynchrony during stress was significantly smaller than during rest in the normal and infarct groups. LV dyssynchrony during rest was significantly larger in the infarct group than in the normal and ischemia groups. There were no significant differences in LV dyssynchrony during rest between the normal and ischemia groups. Stress-induced myocardial ischemia caused dyssynchronous contraction in the ischemic region, leading to a deterioration in LV synchrony. Normal myocardium had more synchronous contraction during stress. The different dyssynchrony pattern between ischemic and normal myocardium early post-stress may aid the diagnosis of coronary artery disease using {sup 201}Tl gated SPECT MPI. (orig.)

  7. Role of myocardial ischemia on exercise-induced ST elevation

    International Nuclear Information System (INIS)

    Saito, Muneyasu; Sumiyoshi, Tetsuya; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kouhei; Haze, Kazuo; Fukami, Ken-ichi; Hiramori, Katsuhiko

    1986-01-01

    Exercise-induced ST elevation in patients with previous myocardial infarction (MI) has been recognized to be related to left ventricular (LV) asynergy, however it is also recognized that myocardial ischemia can induce ST elevation. In this study, factors which determine the extent of ST elevation, with special reference to myocardial ischemia, was re-evaluated using quantitative analysis of stress myocardial scintigraphy (S-SG). Among 65 patients with previous anterior myocardial infarction and documented single vessel disease of left anterior descending artery (LAD), 19 patients who had exercise-induced ST elevation (ΔST ≥ 2.0 mm) had more abnormal Q waves (p < 0.01), lower LV ejection fraction (EF) (p < 0.01), more severe LV asynergy (p < 0.05) and less incidence of post-MI angina pectoris (AP) (p < 0.01), compared to those with ΔST < 2.0 mm, indicating that ST elevation is primarily related to LV asynergy. Correlation studies among clinical, angiographic and scintigraphic parameters show that ΔST was significantly related to a size of MI represented by Tl score or relative defect Tl activity and number of abnormal Q waves (No.Q), the magnitude of work load expressed by changes in double product (ΔDP) and intervals between the onset and exercise test, as well as myocardial ischemia expressed by the extent of redistribution (%RD) in S-SG. Among 23 patients with post-MI AP, ΔST significantly correlated with %RD (r = 0.47), indicating that myocardial ischemia can be a mechanism of exercise-induced ST elevation in patients with previous MI. Furtheremore, among those with ST elevation, concave-type ST elevation was more related to myocardial ischemia compared to convex-type ST elevation as expressed by the incidence of post-MI AP and/or significant redistribution. (J.P.N.)

  8. The usefulness of treatment evaluation of severe heart failure by ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Ohkoshi, Nobuyuki; Watanabe, Shingo; Matsumoto, Tooru

    2011-01-01

    Our purpose of study was to investigate the usefulness of treatment evaluation of severe heart failure by Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT). We evaluated the cardiac function in the case of severe heart failure by gated SPECT and compared it with the cardiac function obtained by left ventriculography (LVG), echocardiography, cardiac MRI, and B-type natriuretic peptide (BNP) values. We investigated the correlation of ejection fraction (EF), time lag of wall motion between the septal and lateral walls of the left ventricle for cardiac resynchronization therapy (CRT) and wall thickening (WT). We classified the left ventricular (LV) into basal, middle and apical areas for comparison of WT. We investigated the effect of a perfusion defect score in these comparisons. The gated SPECT results were correlated with comparative subjects in EF. The results were correlated with MRI on the middle area of the LV in the comparison of WT. We thought it was possible that there was an effect from a perfusion defect score in a time lag comparison of wall motion. Treatment evaluation of severe heart failure by gated SPECT is useful, because it is able to obtain three-dimensional cardiac function analysis, and it offers objectivity and reproducible quantitative evaluation. At the same time, perfusion SPECT is helpful for CRT and LV-plasty. (author)

  9. Clinical usefulness of {sup 123}I-BMIPP myocardial SPECT in collagen disease

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kazuki; Zen, Kan [Asahi Univ., Gifu (Japan). Murakami Memorial Hospital; Sugihara, Hiroki (and others)

    2000-07-01

    This study was designed to evaluate the clinical usefulness of {sup 123}I-BMIPP myocardial SPECT for detecting cardiac involvement in patients with collagen disease. We studied 12 patients with systemic lupus erythematosus (SLE), 8 with progressive systemic sclerosis (PSS), 6 with polymyositis/dermatomyositis (PM/DM) and 3 with allergic granulomatosis and angiitis (AGA). A 111 MBq of {sup 123}I-BMIPP was intravenously injected at rest, and SPECT images were obtained at 15 min after the injection. Seven of 12 SLE, 6 of 8 PSS, 3 of 6 PM/DM and all 3 AGA patients showed an abnormal tracer uptake. The left ventricular ejection fraction was inversely correlated with a BMIPP abnormality. The regional wall motion abnormality was reduced in regions with reduced tracer uptake. These findings suggest that {sup 123}I-BMIPP imaging could be useful for assessment of cardiac involvement in patients with collagen disease. (author)

  10. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and99mTc-tetrofosmin: Method and validation

    OpenAIRE

    Shrestha, U; Sciammarella, M; Alhassen, F; Yeghiazarians, Y; Ellin, J; Verdin, E; Boyle, A; Seo, Y; Botvinick, EH; Gullberg, GT

    2017-01-01

    © 2015, American Society of Nuclear Cardiology. Background: The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Methods: Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients w...

  11. ROC evaluation of SPECT myocardial lesion detectability with and without single iteration non-uniform Chang attenuation compensation using an anthropomorphic female phantom

    International Nuclear Information System (INIS)

    Jang, S.; Jaszczak, R.J.; Duke Univ. Medical Center, Durham, NC; Gilland, D.R.; Turkington, T.G.; Coleman, R.E.; Tsui, B.M.W.; Metz, C.E.

    1998-01-01

    The purpose of this work was to evaluate lesion detectability with and without nonuniform attenuation compensation (AC) in myocardial perfusion SPECT imaging in women using an anthropomorphic phantom and receiver operating characteristics (ROC) methodology. Breast attenuation causes artifacts in reconstructed images and may increase the difficulty of diagnosis of myocardial perfusion imaging in women. The null hypothesis tested using the ROC study was that nonuniform AC does not change the lesion detectability in myocardial perfusion SPECT imaging in women. The authors used a filtered backprojection (FBP) reconstruction algorithm and Chang's single iteration method for AC. In conclusion, with the proposed myocardial defect model nuclear medicine physicians demonstrated no significant difference for the detection of the anterior wall defect; however, a greater accuracy for the detection of the inferior wall defect was observed without nonuniform AC than with it. Medical physicists did not demonstrate any statistically significant difference in defect detection accuracy with or without nonuniform AC in the female phantom

  12. Quantitative assessment of the infarct size with the unfolded map method of sup 201 Tl myocardial SPECT in patient with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Masahiro (Sapporo Medical Coll. (Japan))

    1992-03-01

    The unfolded map method of {sup 201}Tl single photon emission computed tomography (SPECT) was evaluated as to the ability to quantify and the clinical reliability in estimation of infarct size. The following results were obtained from basic experiments using a thoracic phantom. The defect area estimated by the unfolded map method was well correlated with the real defect area, in spite of overestimation of the defect area, when the defect area was determined by an isocount method (below 80% of maximum count) (y=1.941 + 2.292x, r=0.971). The defect volume estimated by short-axis images of {sup 201}Tl SPECT was closely correlated with real defect volume in spite of overestimation of defect volume (y=0.762 + 2.156x, r=0.982). When the defect area was estimated by division of the defect volume by the mean myocardial compartment thickness, it was closely correlated with real defect area (y=0.946 + 1.232x, r=0.990). When the volume was calculated from the summation of voxels in the regions districted by isocount threshold level at each section of the {sup 99m}Tc SPECT, the optimal isocount threshold level (percentage to maximum count) was 55%. Then, the clinical reliability of the unfolded map method as infarct sizing was evaluated in 26 patients with acute myocardial infarction by comparing it with enzymatic method, Bull's eye method, and {sup 99m}Tc pyrophosphate (PYP) SPECT method. In 14 first attack patients without right ventricular infarction, infarct area (IA) of the unfolded map method correlated most closely with the accumulated creatine kinase MB isoenzyme release (CK-MBr) (r=0.897), compared with the extent score (ES) (r=0.853) and the severity score (SS) (r=0.871) of Bull's eye method and the infarct volume (IV) (r=0.595) of {sup 99m}Tc PYP SPECT. In conclusion, although the unfolded map method of {sup 201}Tl SPECT has the tendency for overestimating infarct size, it is accurate and clinically reliable in estimating infarct size. (author).

  13. Safety and feasibility of thallium-201 myocardial SPECT with intravenous infusion of disodium adenosine triphosphate (ATP) in the diagnosis of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pai, Moon Sun; Park, Chan H.; Yoon, Seok Nam; Kim, Won; Kim, Han Soo [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1998-08-01

    ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet bee sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-102 myocardial SPECT using an intravenous ATP infusion in patients with suspected coronary artery disease. Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Although 76.5% of he patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease.

  14. Safety and feasibility of thallium-201 myocardial SPECT with intravenous infusion of disodium adenosine triphosphate (ATP) in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Pai, Moon Sun; Park, Chan H.; Yoon, Seok Nam; Kim, Won; Kim, Han Soo

    1998-01-01

    ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet bee sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-102 myocardial SPECT using an intravenous ATP infusion in patients with suspected coronary artery disease. Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Although 76.5% of he patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease

  15. Interpretative intra- and interobserver reproducibility of Stress/Rest 99m Tc-steamboat's myocardial perfusion SPECT using semi quantitative 20-segment model

    International Nuclear Information System (INIS)

    Fazeli, M.; Firoozi, F.

    2002-01-01

    It well established that myocardial perfusion SPECT with 201 T L or 99 mTc-se sta mi bi play an important role diagnosis and risk assessment in patients with known or suspected coronary artery disease. Both quantitative and qualitative methods are available for interpretation of images. The use of a semi quantitative scoring system in which each of 20 segments is scored according to a five-point scheme provides an approach to interpretation that is more systematic and reproducible than simple qualitative evaluation. Only a limited number of studies have dealt with the interpretive observer reproducibility of 99 mTc-steamboat's myocardial perfusion imaging. The aim of this study was to assess the intra-and inter observer variability of semi quantitative SPECT performed with this technique. Among 789 patients that underwent myocardial perfusion SPECT during last year 80 patients finally need to coronary angiography as gold standard. In this group of patients a semi quantitative visual interpretation was carried out using short axis and vertical long-axis myocardial tomograms and a 20-segments model. These segments we reassigned on six evenly spaced regions in the apical, mid-ventricular, and basal short-axis view and two apical segments on the mid-ventricular long-axis slice. Uptake in each segment was graded on a 5-point scale (0=normal, 1=equivocal, 2=moderate, 3=severe, 4=absence of uptake). The steamboat's images was interpreted separately w ice by two observers without knowledge of each other's findings or results of angiography. A SPECT study was judged abnormal if there were two or more segments with a stress score equal or more than 2. We con eluded that semi-quantitative visual analysis is a simple and reproducible method of interpretation

  16. Prediction of functional recovery after revascularization using quantitative gated myocardial perfusion SPECT: a multi-center cohort study in Japan

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Tamaki, Nagara; Kuwabara, Yoichi; Kawano, Masaya; Matsunari, Ichiro; Taki, Junichi; Nishimura, Shigeyuki; Yamashina, Akira; Ishida, Yoshio; Tomoike, Hitonobu

    2008-01-01

    Prediction of left ventricular functional recovery is important after myocardial infarction. The impact of quantitative perfusion and motion analyses with gated single-photon emission computed tomography (SPECT) on predictive ability has not been clearly defined in multi-center studies. A total of 252 patients with recent myocardial infarction (n = 74) and old myocardial infarction (n = 175) were registered from 25 institutions. All patients underwent resting gated SPECT using 99m Tc-hexakis-2-methoxy-isobutyl isonitrile (MIBI) and repeated the study after revascularization after an average follow-up period of 132 ± 81 days. Visual and quantitative assessment of perfusion and wall motion were performed in 5,040 segments. Non-gated segmental percent uptake and end-systolic (ES) percent uptake were good predictors of wall motion recovery and significantly differed between improved and non-improved groups (66 ± 17% and 55 ± 18%, p 99m Tc-MIBI uptake provided a useful predictor of wall motion improvement. Application of quantitative approach with non-gated and ES percent uptake enhanced predictive accuracy over visual analysis particularly in a multi-center study. (orig.)

  17. Gated myocardial SPECT using spatial and temporal filtering

    International Nuclear Information System (INIS)

    Hatton, R.L.; Hutton, B.F.; Kyme, A.Z.; Larcos, G.

    2002-01-01

    Full text: Standard protocols for examining myocardial perfusion and motion defects involve the use of gated SPECT images, and a composite of the gated frames. This study examines the usefulness of extracting one or a combination of frames from the gated image to assess perfusion, and whether the addition of a temporal filter to the gated image improves signal to noise. Choice of the most appropriate frame was also considered. Sixteen and eight frame gated SPECT studies were simulated using the dynamic NURBS-based cardiac torso (NCAT) phantom. Variously sized perfusion defects were included in the inferior wall to assess contrast to normal tissue. Scatter and attenuation were not included. Butterworth spatial cutoff frequencies were varied to establish the most appropriate combination of temporal/spatial filters to reduce noise and retain contrast in the images. The 16 frame data produced higher ejection fraction across all spatial filter cutoffs, and generally was unaffected by temporal filtering. Temporal filtering reduced the noise in a uniform liver region in the gated images to within 25% of the composite image noise. The lesion extent and contrast were greater in the end-diastolic frames compared to end-systolic and mid-cycle frames. In conclusion, by using a temporally filtered end-diastolic image from the gated sequence, a favourable balance between noise and contrast can be achieved. Work is progress to confirm these findings in the clinical situation. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  18. The significance of 123I-BMIPP myocardial SPECT on the evaluation of angina pectoris

    International Nuclear Information System (INIS)

    Kurosawa, Kazuhiko; Ohtani, Hiroshi; Saitou, Tomiyoshi; Maruyama, Yukio; Katohno, Eiichi; Ohwada, Kenji

    1998-01-01

    Some patients of ischemic heart disease have low uptake in 123 I-labeled beta methyl-iodophenyl pentadecanoic acid (BMIPP) SPECT in spite of normal uptake in thallium-201 (Tl) SPECT. To investigate their clinical significance, we performed both Tl and BMIPP myocardial SPECT in 26 cases with stable angina (n=16) and unstable angina (n=10), and compared with clinical backgrounds electrocardiogram (ECG) and left ventriculography (LVG). In 11 patients of them, the uptake of BMIPP was moderately reduced. We divided 26 cases into two groups according to uptake of BMIPP (normal/reduced). The two groups had no differences in length of angina attack and duration of disease, but they had a significant difference in the abnormality of either ECG or LVG. Three to six months after PTCA, we examined LVG in 18 cases, 12 of 16 cases with the abnormality of LVG showed the improvement of wall motion. We concluded the reduced uptake of BMIPP with normal uptake of Tl was related to more severe ischemia in cases with unstable angina. (author)

  19. Myocordial perfusion SPECT with dipyridamole stress test in cardiac syndrome X

    International Nuclear Information System (INIS)

    Czepczynski, R.; Smolarek, I.; Sowinski, J.; Rogacka, D.; Kazmierczak, M.; Wysocki, H.

    2006-01-01

    Cardiac syndrome X defines patients with typical anginal chest pain, a positive exercise ECG stress test and angiographically normal coronary arteries. Aim of this study was to evaluate the role of myocardial perfusion SPECT with dipyridamole stress in the diagnosis of cardiac syndrome X. Patients, methods: 68 patients with syndrome X aged 32 to 60 years were subjected to myocardial imaging using 99m Tc-MIBI according to the two-days protocol: at rest and after dipyridamole infusion. Semiquantitative evaluation of the images was based on the assessment of 99m Tc-MIBI uptake in 17 myocardial segments using a 5-points scale (0 point - normal uptake, 4 points - no uptake). Scores obtained in each segment were summed up, constituting the summed rest score (SRS) and summed stress score (SSS). Results: mean SRS was 7.9 ± 4.8 and mean SSS was 7.2 ± 4.4 (non-significant difference). Individual comparison of SRS and SSS values revealed three patterns of scintigraphic images: (1) in 25 patients (36.8%), a paradoxical improvement of perfusion at stress images was found, (2) in 23 patients (33.8%), the myocardial perfusion deteriorated after dipyridamole, (3) in 20 patients (29.4%), no significant change of the myocordial perfusion between rest and stress images occurred. Conclusions: in cardiac syndrome X, myocardial SPECT with dipyridamole stress shows different patterns of myocardial perfusion that reflects heterogeneity of this pathology. (orig.)

  20. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation; Valoracion no invasiva de la enfermedad ateroesclerosa coronaria en pacientes con isquemia silente: utilidad del SPECT de perfusion miocardica. Correlacion electrica, angiografica y de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E. [Hospital Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico)

    2005-07-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis.

  1. Quantitative evaluation of right ventricular overload in cor pulmonale using 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Kato, Hiroshi; Misawa, Toshihiro; Kutsumi, Yasunori

    1991-01-01

    To determine quantitatively the discriminant and characteristics of cor pulmonale, 201 Tl myocardial perfusion SPECT was performed in 16 patients with chronic obstructive pulmonary disease (COPD) and 7 with restrictive pulmonary disease (RPD). One section of the short-axis SPECT image in which the right ventricle was most clearly visualized was selected. Tl-score was defined as the ratio of the sum of counts in the region of interest (ROI) at the anterior, mid, and posterior regions of the right ventricular free wall to the sum of counts in ROI at the posterior, lateral, and anterior walls of the left ventricle, and the anterior and posterior regions of the interventricular septum. In the group of COPD patients, Tl-score was positively correlated with mean pulmonary arterial pressure (mPAP), total pulmonary vascular resistance (TPR), and arterial carbon dioxide tension (PaCO 2 ), while it was inversely correlated with arterial oxygen tension (PaO 2 ). However, there was no significant correlation between Tl-score and mPAP, TPR, PaCO 2 , and PaO 2 in the group of RPD patients. In assessing pulmonary hypertension as defined by mPAP over 20 mmHg, a Tl-score greater than 0.25 was useful with a sensitivity of 69% and a specificity of 90%. The occurrence of cor pulmonale is a major factor in determining the prognosis of COPD patients. It was concluded that 201 Tl myocardial SPECT is useful for evaluating right ventricular overload quantitatively, as well as for assessing core pulmonale, especially in COPD patients, since the ratio of Tl counts in the right and left ventricles was significantly correlated with right cardiopulmonary hemodynamic parameters. (N.K.)

  2. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    International Nuclear Information System (INIS)

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn; Wei, Lihui

    2015-01-01

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision

  3. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    Energy Technology Data Exchange (ETDEWEB)

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn, E-mail: gwells@ottawaheart.ca [Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario K1Y4W7 (Canada); Wei, Lihui [Nordion, Inc., Ottawa, Ontario K2K 1X8 (Canada)

    2015-09-15

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.

  4. ST-vector orientation and location of myocardial perfusion defects during exercise

    International Nuclear Information System (INIS)

    Simoons, M.L.; Withagen, A.; Vinke, R.; Kooy, P.; Bakker, W.; Erasmus Universiteit, Rotterdam

    1978-01-01

    In 34 patients with chest pain the spatial orientation of the ST-vectors in the exercise electrocardiogramm 30 and 80 msec after the end of QRS were compared with the location of exercise induced local defects of myocardial uptake of 201 Tl. The following results were obtained: 1. The sensitivity and specifity of myocardial perfusion imaging after exercise were the same as those of exercise electrocardiograms; 2. No relation could be observed beween the location of reduced 201 Tl uptake during exercise and the spatial orientation of the ST-vectors. (orig.) [de

  5. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Hung, Guang-Uei; Huang, Jin-Long; Lin, Wan-Yu; Tsai, Shih-Chung; Wang, Kuo-Yang; Chen, Shih-Ann; Lloyd, Michael S.; Chen, Ji

    2014-01-01

    The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of 99m Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ∝0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy. (orig.)

  6. Benefits of lifelong exercise training on left ventricular function after myocardial infarction

    NARCIS (Netherlands)

    Maessen, M.F.H.; Eijsvogels, T.M.H.; Stevens, G.G.; Dijk, A.P.J. van; Hopman, M.T.E.

    2017-01-01

    Background Endurance exercise training induces cardio-protective effects, but athletes are not exempted from a myocardial infarction. Evidence from animal studies suggests that exercise training attenuates pathological left ventricular remodelling following myocardial infarction. We tested the

  7. Screening for silent myocardial ischemia caseof diabetics : interest of myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Bahri, Haifa

    2007-01-01

    Silent myocardial ischemia is a major cause of morbidity and mortality in diabetic patients. Its diagnosis by noninvasive means such as myocardial SPECT would improve the management of these patients. The purpose of this study is to assess the frequency of silent myocardial ischemia in asymptomatic diabetics and their evolution. As a result, the myocardial SPECT is a reliable tool for screening for silent myocardial ischemia in diabetic patients. Its prognostic value allows to stratify the cardiac risk and guide therapeutic management. Its integration into a screening strategy in Tunisia seems limited by its low availability and cost. The latter could be reduced by better patient selection.

  8. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Van Staden, J.A.; Herbst, C.P.; Du Raan, H.; Lotter, M.G.; Otto, A.C.

    2004-01-01

    Full text: Introduction: Gated myocardial perfusion SPECT has been used to calculate left ventricular ejection fraction (LVEF) and left ventricular end-diastolic volume (LVEDV) and has correlated well with conventional methods. However, the comparative accuracy of and correlations across various types of gated SPECT software are not well understood. Materials and methods: Twelve patients participated in a radionuclide gated blood-pool (GBP) study in addition to undergoing 99m Tc-sestamibi gated SPECT. Three different software algorithms, Quantitative Gated SPECT (QGS) from Cedars-Sinai, MultiDim from Stanford University Medical School and GQUANT from Alfa Nuclear were used to compute LVEF and LVEDV. These software algorithms operate in 3-dimensional space, two dependent on surface detection and the other on statistical parameters. The LVEF as calculated from gated SPECT myocardial perfusion images were compared with LVEF calculated from the GBP studies in the same patients to assess accuracy of the three software algorithms. Results: The software success-rate was 92% (11/12 pts) for MultiDim and 100% for the QGS and GQUANT. Agreement between LVEF measured with MultiDim and QGS, MultiDim and GQUANT and QGS and GQUANT were excellent (LVEF-MuItidim 0.80 LVEF QGS +5.02, r = 0.93, LVEF GQUANT = 1.10 LVEF MuItidim -1.33, r 0.90 and LVEF GQUANT = 1.02 LVEF QGS -1.40, r = 0.96). The correlation coefficient for LVEF between gated SPECT and the GBP study was 0.95, 0.95 and 0.97, for MultiDim, GQUANT and QGS, respectively. Conclusion: All 3 software programs showed good correlation between LVEF for gated SPECT and the GBP study. Good agreement for LVEF was observed also between the three software algorithms. However, because each method has unique characteristics that depend on its specific algorithm and thus behaves differently in the various patients, the methods should not be used interchangeably. (author)

  9. Exercise training prior to myocardial infarction attenuates cardiac deterioration and cardiomyocyte dysfunction in rats

    Directory of Open Access Journals (Sweden)

    Luiz Henrique Marchesi Bozi

    2013-04-01

    Full Text Available OBJECTIVES: The present study was performed to investigate 1 whether aerobic exercise training prior to myocardial infarction would prevent cardiac dysfunction and structural deterioration and 2 whether the potential cardiac benefits of aerobic exercise training would be associated with preserved morphological and contractile properties of cardiomyocytes in post-infarct remodeled myocardium. METHODS: Male Wistar rats underwent an aerobic exercise training protocol for eight weeks. The rats were then assigned to sham surgery (SHAM, sedentary lifestyle and myocardial infarction or exercise training and myocardial infarction groups and were evaluated 15 days after the surgery. Left ventricular tissue was analyzed histologically, and the contractile function of isolated myocytes was measured. Student's t-test was used to analyze infarct size and ventricular wall thickness, and the other parameters were analyzed by the Kruskal-Wallis test followed by Dunn's test or a one-way analysis of variance followed by Tukey's test (p<0.05. RESULTS: Myocardial infarctions in exercise-trained animals resulted in a smaller myocardial infarction extension, a thicker infarcted wall and less collagen accumulation as compared to myocardial infarctions in sedentary animals. Myocardial infarction-induced left ventricular dilation and cardiac dysfunction, as evaluated by +dP/dt and -dP/dt, were both prevented by previous aerobic exercise training. Moreover, aerobic exercise training preserved cardiac myocyte shortening, improved the maximum shortening and relengthening velocities in infarcted hearts and enhanced responsiveness to calcium. CONCLUSION: Previous aerobic exercise training attenuated the cardiac dysfunction and structural deterioration promoted by myocardial infarction, and such benefits were associated with preserved cardiomyocyte morphological and contractile properties.

  10. Comparison of Diagnostic Accuracy for Detecting coronary Artery Disease of Dipyridamole 99mTc-MIBI Myocardial SPECT and It's Defect Map between Men and Women

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Oh, Byung Hee; Chung, June Key; Lee, Myoung Mook; Park, Young Bae; Lee, Myung Chul; Seo, Jung Don; Lee, Young Woo; Koh, Chang Soon

    1993-01-01

    To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole 99m Tc-MIBI myocardial SPECT, we obtained 99m Tc-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole 99m Tc- MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex(LCX) and 8% for right coronary artery (RCA) territories. Lesions ≥ 50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns); specificity was 84.6% in men and 67.9% in women (P 99m Tc-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  11. Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Matsudaira, Masamichi; Hisada, Kinichi; Kanayama, Sugako; Yoneyama, Tatsuya; Nakajima, Kenichi; Taki, Junichi; Tonami, Norihisa; Nekolla, Stephan G.

    2005-01-01

    Dual-isotope simultaneous acquisition single-photon emission computed tomography (DISA SPECT) with 18 F-fluorodeoxyglucose (FDG) and 99m Tc-sestamibi appears attractive for the detection of viable myocardium because it permits simultaneous assessment of glucose utilisation and perfusion. Another potential benefit of this approach is that the measurement of left ventricular (LV) function may be possible by ECG gating. The aim of this study was to test the hypothesis that both myocardial viability and LV function can be assessed by a single ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT study, based on comparison with 18 F-FDG/ 13 N-ammonia positron emission tomography (PET) and magnetic resonance imaging (MRI) as reference techniques. Thirty-three patients with prior myocardial infarction underwent ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT and 18 F-FDG/ 13 N-ammonia PET on a single day. Of these, 25 patients also underwent cine-MRI to assess LV function. The LV myocardium was divided into nine regions, and each region was classified as viable or scar using a semiquantitative visual scoring system as well as quantitative analysis. The global and regional LV function measured by gated SPECT was compared with the results of MRI. There was good agreement in respect of viability (90-96%, κ0.74-0.85) between DISA SPECT and PET by either visual or quantitative analysis. Furthermore, although both global and regional LV function measured by gated SPECT agreed with those by MRI, 99m Tc-sestamibi showed a closer correlation with MRI than did 18 F-FDG. In conclusion, ECG-gated DISA SPECT provides information on myocardial viability, as well as global and regional LV function, similar to that obtained by PET and MRI. (orig.)

  12. Coronary flow reserve index corrected by exercise load using Tl-201 SPECT

    International Nuclear Information System (INIS)

    Kubota, Yasushi; Sugihara, Hiroki; Azuma, Akihiro

    1990-01-01

    For simple, non-invasive evaluation of coronary flow reserve during exercise, we investigated the coronary flow reserve index using the ratio of change of fractional distribution in the regional myocardium to oxygen demand. The subjects included 24 patients with effort angina pectoris and 11 normal volunteers. PTCA was peformed for 11 patients. Using the biological properties of Tl-201 single photon emission computed tomography (SPECT) was performed at submaximal exercise and at rest by two successive injections of Tl-201 within a short time interval (double dose method). The correlation between the fractional distribution in the myocardium (Δ-Fract) and the oxygen demand during exercise and at rest were evaluated. Δ-Fract correlated well with the rate of change of the pressure rate product (Δ-PRP), and Δ-Fract/Δ-PRP (CRI) was a good indicator of the coronary flow reserve index. CRI in the ischemic region correlated well with the percent area stenosis of the supplying coronary artery and improved with resolution of percent area stenosis of the target coronary artery after PTCA, but in some cases they were not above the normal range. CRI as obtained by exercise SPECT using the double dose method is useful for non-invasively estimating the coronary flow reserve during exercise, and it can be used for evaluating the effect before and after PTCA. (author)

  13. Normal 201Tl SPECT myocardial scintigram - a basis for quantification of tomographic data using 1800 rotation

    International Nuclear Information System (INIS)

    Bock, A.; Frenzel, R.; Meyer, M.; Pink, V.; Reisinger, I.; Strangfeld, D.

    1990-01-01

    Using 180 0 rotation for 201 Tl myocardial perfusion SPECT the influence of different myocardial wall thickness, depth-dependent resolution, attenuation and other facts is the reason for about 30% inhomogenity from anterolateral to posteroseptal myocardium in polar coordinate Bull's eye. It is very difficult for a visual observer to assess patients without knowledge of the corresponding normal distribution. We studied 25 normal males and calculated pixelwice vitality, washout rate between stress, 2-hr and 3.5-hr delay to obtain a normal Bull's eye reference databank. Before the patient's data can be analysed it is necessary to multiplicate them with the inverse normal Bull's eye. (author)

  14. Diagnosis of severe and extensive coronary artery disease using gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Lee, Hyoung Woo; Won, Kyu Chang; Park, Jong Sun; Sin, Dog Gu; Kim, Young Jo; Shim, Bong Sub [College of Medicine, Yeungnam Univ., Taegu (Korea, Republic of)

    1999-07-01

    Left ventricular volumes and ejection fractions constitute important informations in the diagnosis and prognosis of cardiac disease. Aim of the study is to verify if the assessment of left ventricular function and perfusion together by gated myocardial perfusion SPECT is useful for diagnosing severe and extensive CAD. We examined 27 consecutive patients (17 males and 10 females, mean age : 60.1 years) who underwent two day rest/stress Tc-99m MIBI gated SPECT. Stress was done with adenosine. Post-stress gated SPECT was done at 1 hour after an injection of Tc-99m MIBI (740 MBq). All patients underwent coronary angiography after gated SPECT within 1 month. We divided them three groups with single vessel disease, double vessel disease and triple vessel disease or severe proximal left coronary artery stenosis. Extent of Defect (ED), Reversibility of Extent (RE), Severity of Defect (SD) and Severity of Reversibility (SR) were calculated by CEqual program. Post-stress LVEF, Rest LVEF, End-diastolic volume(EDV), End-systolic volume(ESV), Transient Ischemic Dilation (TID) of left ventricle (Post-stress EDV/Rest EDV) were calculated using gated SPECT quantification program. Left ventricle is divided with 18 segments and wall motion was scored (normal=0, mild hypokinesia =1, severe hypokinesia =2, akinesia =3 and dyskinesia =4), and then post-stress summed wall motion score was calculated. Post-stress summed wall motion score and post-stress LVEF were significant differences between three groups ( P <0.01). Extent of defect, Extent of reversibility, Severity of defect and severity of reversibility in Polar map were significant differences between three groups ( P <0.01). Post-stress Transient left ventricular dilatation and test LVEF were not significant differences between three groups ( P > 0.05). The gated SPECT pattern (low post-stress LVEF and post-stress summed wall motion score) add important diagnostic information over ungated perfusion data (high ED, ER and SR and

  15. Comparative value of brain perfusion SPECT and [{sup 123}I]MIBG myocardial scintigraphy in distinguishing between dementia with Lewy bodies and Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Iwamoto, Toshihiko [Tokyo Medical University, Department of Geriatric Medicine, Tokyo (Japan); Chikamori, Taishiro; Usui, Yasuhiro; Yamashina, Akira [Tokyo Medical University, 2. Department of Internal Medicine, Tokyo (Japan); Koizumi, Kiyoshi; Abe, Kimihiko [Tokyo Medical University, Department of Radiology, Tokyo (Japan)

    2006-03-15

    Both decreased occipital perfusion on brain single-photon emission computed tomography (SPECT) and reduction in cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) uptake are characteristic features of dementia with Lewy bodies (DLB), and potentially support the clinical diagnosis of DLB. The aim of this study was to compare the diagnostic value of these two methods for differentiation of DLB from Alzheimer's disease (AD). The study population comprised 19 patients with probable DLB and 39 patients with probable AD who underwent both SPECT with N-isopropyl-p-[{sup 123}I]iodoamphetamine and MIBG myocardial scintigraphy. Objective and quantitative measurement of perfusion in the medial occipital lobe, including the cuneus and lingual gyrus, was performed by the use of three-dimensional stereotactic surface projections. Medial occipital perfusion was significantly decreased in the DLB group compared with the AD group. The mean heart/mediastinum ratios of MIBG uptake were significantly lower in the DLB group than in the AD group. Although SPECT failed to demonstrate significant hypoperfusion in the medial occipital lobe in five patients with DLB, marked reduction of MIBG uptake was found in all patients with DLB. Receiver operating characteristic analysis revealed that MIBG myocardial scintigraphy enabled more accurate discrimination between DLB and AD than was possible with perfusion SPECT. MIBG myocardial scintigraphy may improve the sensitivity in the detection of DLB. In particular, this method may provide a powerful differential diagnostic tool when it is difficult to distinguish cases of DLB from AD using brain perfusion SPECT. (orig.)

  16. Requirements of exercise myocardial scintigraphy (EMS) using Tl-201 prior and subsequent to coronary revascularisation, based on the example of transluminal angioplasty

    International Nuclear Information System (INIS)

    Maul, F.D.; Hoer, G.; Standke, R.; Kober, G.; Klepzig, H. Jr.; Doerr, G.; Baum, R.P.; Happ, J.; Kaltenbach, M.; Frankfurt Univ.

    1985-01-01

    Quantitative exercise myocardial scintigraphy (EMS) using Thallium-201 in planar technique was applied in 128 patients prior and subsequent to transluminal coronary angioplasty. The overall sensitivity was 92%, and 88% for multivessel disease. In contrast to previous reports, the sensitivity for lesions of the posterior wall proved not inferior to that for lesions of the anterior wall: RCA-stenoses 92%; LCX-stenoses 100% and RIA-stenoses 93%. The specificity was found to be 88%, and the accuracy 92%. Myocardial ischaemia, as detected by EMS and ex. ECG, amounted to 84% and 72%, respectively in single vessel disease. The degree of ischaemia, which was measured semiquantitatively in terms of score, paralleled that of stenosis. The accuracy for localisation of anterior or posterior wall lesions was 92%. In unsuccessfully treated patients the results were completely reproducible (100%) both in terms of the decision 'CAD yes or no', and regarding the localisation of a myocardial lesion. The reproducibility for detection of myocardial ischaemia was 82%. Conclusion: In comparison with SPECT the quantitative planar EMS procedure using Tl-201 is the method of choice for the detection and assessment of ischaemia prior and subsequent to revascularisation therapy. (orig.) [de

  17. Evaluation of a method to determine the myocardial uptake from 123I-BMIPP myocardial SPECT and its significance

    International Nuclear Information System (INIS)

    Iwase, Mikio; Toriyama, Takayuki; Itou, Masato; Shimao, Ryuichiro; Ikeda, Koshiro; Suzuki, Takeshi; Nobuta, Takaaki; Iida, Akihiko.

    1996-01-01

    We examined methods of calculating myocardial uptake (TU) of 123 I-BMIPP by SPECT, and compared TU to heart function (ejection fraction (EF), cardiac output (CO), cardiac index (CI)) calculated by left ventriculography. Forty-two patients with acute myocardial infarction were classified into 5 groups; within 1 week (I), from 1 to 2 weeks (II), from 2 weeks to 1.5 months (III), from 1.5 to 3 months (IV) and more than 3 months (V) after percutaneous transluminal coronary angioplasty (PTCA). Chest depth (Tw) was calculated by measuring the thoracic absorption rate of 123 I. In calculating TU, the myocardial count was calculated from short-axis tomograms, and then absorption was corrected using Tw to calculate each value on early-phase image (E) and delay-phase image (D). The influence of lung uptake on myocardial count was only 1.76%. When TU was compared to heart function, there were correlations between group I and group V. Especially in group VD-TU was a significantly correlated with heart function. In heart function CI, but not EF nor CO, was significantly correlated with TU. It was suggested that the correlation between TU and heart function reflected the infarct condition before PTCA in group I, and that the individual difference in recovery of fatty acid metabolism in group V. The significant correlation between D-TU and CI suggests that D-TU reflects heart function and fatty acid metabolism, although TU is influenced by differences in physical status. (author)

  18. Therapeutic effects of coenzyme Q10 on dilated cardiomyopathy. Assessment by {sup 123}I-BMIPP myocardial single photon emission computed tomography (SPECT). A multicenter trial in Osaka University Medical School Group

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Hori, Masatsugu [Osaka Univ. (Japan). Faculty of Medicine

    1996-01-01

    To evaluate therapeutic effects of Coenzyme Q10 (CoQ10), 15 patients with dilated cardiomyopathy were investigated by {sup 123}I-BMIPP myocardial single photon emission computed tomography (SPECT). The BMIPP defect score was determined semiquantitatively by using representative short and long axial SPECT images. Mean BMIPP defect score with CoQ10 treatment was significantly low, 7.7{+-}6.1 compared to 12.7{+-}7.4 without CoQ10 treatment. On the other hand, in 8 patients of dilated cardiomyopathy, % fractional shortening using echocardiography was not different before and after CoQ10 treatment. In conclusion, {sup 123}I-BMIPP myocardial SPECT was proved to be sensitive to evaluate the therapeutic effects of CoQ10, which improve myocardial mitochondrial function, in the cases of dilated cardiomyopathy. (author).

  19. An attempt of thallium-201 myocardial perfusion imaging during transient coronary arterial occlusion by PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Katahira, Toshio

    1989-01-01

    To evaluate the myocardial perfusion during transient coronary occlusion, we attempted to obtain the myocardial scintigraphy during percutaneous transluminal coronary angioplasty (PTCA). Tl-201 was injected at the last inflation of angioplastic balloon and occlusion was kept on for 60 sec. Planar images or SPECT were obtained immediately after PTCA. With this protocol, myocardial perfusion defects were observed during PTCA and fully redistributed 3 hours after Tl injection. Extent of ischemic lesions were almost same as that observed during exercise in two cases without collateral vessels. In a case with well visualized collateral vessels, perfusion defect was smaller in PTCA images than that in exercise stressed images. We conclude that intravenous injection of Tl-201 during PTCA is useful to assess the alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedure. (author)

  20. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  1. Simultaneous thallium-201/technetium-99m pyrophosphate tomography in patients with acute myocardial infarction: comparison of rotational SPECT and seven pinhole tomography

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Beck, A.; Moser, E.; Zeiher, A.

    1992-01-01

    Simultaneous Tl-201/Tc-99m pyrophosphate (PPi) tomography was compared to Tc-99m PPi tomography and rotational SPECT (SPECT) was compared to seven pinhole tomography (9-PHT), respectively, in 19 patients with acute myocardial infarction (AMI). The results were correlated to electrocardiographic and angiographic findings. With Tl-201/Tc-99, PPi, all infarctions were detected and site of infarction was determined, independent of the tomographic technique used. There was no significant difference between the two acquisition techniques 7-PHT and SPECT concerning spatial extent of Tc-99m PPi accumulation and the uptake ratio. However, using only Tc-99m PPi without Tl-201 as anatomical marker, SPECT detected 15/19 infarctions. In 7 of these 15 cases infarction site was correctly determined. 7-PHT detected 11/19 and site was correctly determined in 9/11 infarctions. Myocardial infarctions which failed diagnosis using Tc-99m PPi alone showed significantly smaller spatial extent of Tc-99m PPi accumulation and necrosis to blood pool ratio was lower as assessed by Tl201/Tc-99m PPi tomography. In conclusions, tomography using simultaneous Tl-201/Tc-99m PPi imaging is a reliable technique for diagnosis and localization of AMI. For this reason, results obtained with SPECT and 7-PHT are comparable. Independent of the tomographic technique used, combined imaging is superior to Tc-99m PPi alone without Tl-201 as additional anatomical marker (orig./MG) [de

  2. Scatter and cross-talk correction for one-day acquisition of 123I-BMIPP and 99mtc-tetrofosmin myocardial SPECT.

    Science.gov (United States)

    Kaneta, Tomohiro; Kurihara, Hideyuki; Hakamatsuka, Takashi; Ito, Hiroshi; Maruoka, Shin; Fukuda, Hiroshi; Takahashi, Shoki; Yamada, Shogo

    2004-12-01

    123I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99mTc-tetrofosmin (TET) are widely used for evaluation of myocardial fatty acid metabolism and perfusion, respectively. ECG-gated TET SPECT is also used for evaluation of myocardial wall motion. These tests are often performed on the same day to minimize both the time required and inconvenience to patients and medical staff. However, as 123I and 99mTc have similar emission energies (159 keV and 140 keV, respectively), it is necessary to consider not only scattered photons, but also primary photons of each radionuclide detected in the wrong window (cross-talk). In this study, we developed and evaluated the effectiveness of a new scatter and cross-talk correction imaging protocol. Fourteen patients with ischemic heart disease or heart failure (8 men and 6 women with a mean age of 69.4 yr, ranging from 45 to 94 yr) were enrolled in this study. In the routine one-day acquisition protocol, BMIPP SPECT was performed in the morning, with TET SPECT performed 4 h later. An additional SPECT was performed just before injection of TET with the energy window for 99mTc. These data correspond to the scatter and cross-talk factor of the next TET SPECT. The correction was performed by subtraction of the scatter and cross-talk factor from TET SPECT. Data are presented as means +/- S.E. Statistical analyses were performed using Wilcoxon's matched-pairs signed-ranks test, and p corrected total count was 26.0 +/- 5.3%. EDV and ESV after correction were significantly greater than those before correction (p = 0.019 and 0.016, respectively). After correction, EF was smaller than that before correction, but the difference was not significant. Perfusion scores (17 segments per heart) were significantly lower after as compared with those before correction (p correction revealed significant differences in EDV, ESV, and perfusion scores. These observations indicate that scatter and cross-talk correction is required for one

  3. Effect of maintenance oral theophylline on dipyridamole-thallium-201 myocardial imaging using SPECT and dipyridamole-induced hemodynamic changes

    International Nuclear Information System (INIS)

    Daley, P.J.; Mahn, T.H.; Zielonka, J.S.; Krubsack, A.J.; Akhtar, R.; Bamrah, V.S.

    1988-01-01

    To evaluate the effect of maintenance oral theophylline therapy on the diagnostic efficacy of dipyridamole-thallium-201 single photon emission computed tomography (SPECT) imaging for coronary artery disease, dipyridamole-thallium-201 SPECT imaging was performed in eight men with documented coronary artery disease before initiation of theophylline treatment and repeated while these patients were receiving therapeutic doses of oral theophylline. Before theophylline treatment, intravenous dipyridamole caused a significant increase in heart rate, decrease in blood pressure, angina in seven of eight patients, and ST segment depression in four of eight patients. While they were being treated with theophylline, none of the patients had angina or ST segment depression, and there were no hemodynamic changes with intravenous dipyridamole. Before theophylline treatment, dipyridamole-thallium-201 SPECT imaging showed reversible perfusion defects in myocardial segments supplied by stenotic coronary arteries. With theophylline treatment, dipyridamole-thallium-201 SPECT showed total absence of reversible perfusion defects. Treatment with theophylline markedly reduced the diagnostic accuracy of dipyridamole-thallium-201 imaging for coronary artery disease

  4. Normal LVEF measurements are significantly higher in females asassessed by post-stress resting Tc-99m sestamibi gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Shin, Eak Kyun

    1999-01-01

    Volume-LVEF relationship is one of the most important factors of automatic EF quantification algorithm from gated myocardial perfusion SPECT(gMPS) (Germano et al. JNM, 1995). Gender difference whereby normal LVEF measurements are higher in females assessed by gMPS (Yao et al. JNM 1997). To validate true physiologic value of LVEF vs sampling or measured error, various parameters were evaluated statistically in both gender and age matched 200 subjects (mean age= 58.41±15.01) with normal LVEF more than 50%, and a low likelihood of coronary artery disease. Correlation between LVEDVi(ml/m2) and LVEF was highly significant (r=-0.62, p<0.0001) with similar correlations noted in both male (r=-0.45, p<0.0001) and female (r=-0.67, p<0.0001) subgroups. By multivariate analysis, LV volume and stroke volume was the most significant factor influencing LVEF in male and female, respectively. In conclusion, there is a significant negative correlation between LV volume and LVEF as measured by Tc-99m gated SPECT. Higher normal LVEF value should be applied to females as assessed by post-stress resting Tc-99m Sestamibi gated myocardial perfusion SPECT

  5. Clinical evaluation of 99mTc-CPI myocardial perfusion single photon emission computerized tomography in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Peng Changping

    1991-01-01

    Two normal subjects, 5 patients with old myocardial infarction (OMI) and 4 patients with angina pectoris were examined by rest single photon emission computerized tomography revealed that the right ventricular was not imaged, the left ventricular was well exposed in the normal subjects. All the 9 patients had defects in the left ventricle. comparison of SPECT with 99m Tc-CPI with selective coronary arteriography (SCA), echocardiography (UCG), dynamic electrocardiography (DCG) and electrocardiographic (ECG)-exercise test in the diagnosis of myocardial ischemia or necrosis has demonstrated the former to be more significantly sensitive than the latter four. Good agreement between SPECT and SCA has been confirmed

  6. Asymmetrically thickened posterior wall is associated with decline of ejection fraction after stress on adenosine stress/rest thallium-201 gated myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Lee, Won Woo; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2004-07-01

    LV parameters (LVEF. ESVI and EDVI) on adenosine stress/rest thallium-201 gated myocardial SPECT (gSPECT) are various from stress to rest. We investigated the reason why they were various in patients without coronary artery disease. Seventy-one patients(M:F=32:39, age 58.1{+-}9.7yrs), who underwent gSPECT and coronary angiography (CAG) due to chest pain or preoperative evaluation were included. CAG results were normal or insignificant. Exclusion criteria were atrial fibrillation, thyroid disease, primary cardiomyopathy, myocardial bridge, LBBB, MI, and valvular heart disease. Patients were calssified into 3 groups by EF difference ({delta}EF=rest-stress EF) on gSPECT : group1 ({delta}EF{>=}10), group2 (0 {<=}{delta}EF<10), and group3 ({delta}EF<0). LV parameters on gSPECT and thicknesses of IVS (interventricular septum) and LVPW (left ventricular posterior wall) on echocardiography were compared among the 3 groups. Myocardial perfusion status were normal or mild reversible/persistent perfusion defect in 76.1% (54/71). LVEFs at stress were not different among all 3 groups : 59.3{+-}8.54% in group 1 (61.3{+-}10.22% in group 2 and 64.8{+-}7.58% in group 3 (p>0.05). But LVEF at rest was smaller in group 3 (58.7{+-}8.38%) than the other groups (72.5{+-}8.77% in group1 and 66.7{+-}10.6% in group2) (p<0.01). EDVIs and ESVI at stress were larger than those at rest in all groups (p<0.05) except ESVI in group 3 (16.2{+-}6.21ml at stress and 17.5{+-}6.41ml at rest, p<0.01), and that was attributed to EF<0 in group 3. In echocardiographical analysis, group 3 had significantly increased wall thickness of LVPW (10.7{+-}1.2mm versus 9.4{+-}1.6mm, p=0.01) and decreased wall thickness ratio of IVS/LVPW (0.963{+-}0.102 versus 1.048{+-}0.104, p=0.035) than group 1. In patients without coronary artery disease, LVEF, EDVI and ESVI on gSPECT were various and decline of LVEF from stress to rest was caused by unnormalized ESVI . Asymmetrically thickened LVPW may play a crucial role and

  7. Association of Exercise Training with Tobacco Smoking Prevents Fibrosis but has Adverse Impact on Myocardial Mechanics.

    Science.gov (United States)

    Reis Junior, Dermeval; Antonio, Ednei Luiz; de Franco, Marcello Fabiano; de Oliveira, Helenita Antonia; Tucci, Paulo José Ferreira; Serra, Andrey Jorge

    2016-12-01

    There was no data for cardiac repercussion of exercise training associated with tobacco smoking. This issue is interesting because some smoking people can be enrolled in an exercise-training program. Thus, we evaluated swimming training effects on the function and structural myocardial in rats exposed to tobacco smoking. Male Wistar rats were assigned to one of four groups: C, untrained rats without exposure to tobacco smoking; E, exercised rats without exposure to tobacco smoking; CS, untrained rats exposed to tobacco smoking; ECS, exercised rats exposed to tobacco smoking. Rats swam five times a week twice daily (60min per session) for 8 weeks. Before each bout exercise, rats breathed smoke from 20 cigarettes for 60min. Twenty-four hours after the last day of the protocol, papillary muscles were isolated for in vitro analysis of myocardial mechanics. The myocardial mass and nuclear cardiomyocyte volume were used as hypertrophy markers, and collagen content was determined by picrosirius red staining. There was a well-pronounced myocardial hypertrophic effect for two interventions. The exercise blunted myocardial collagen increases induced by tobacco smoking. However, exercise and tobacco-smoking association was deleterious to myocardial performance. Thereby, in vitro experiments with papillary muscles contracting in isometric showed impairment myocardial inotropism in exercised rats exposed to tobacco smoking. This work presents novel findings on the role of exercise training on cardiac remodeling induced by tobacco smoking. Although exercise has mitigated tissue fibrosis, their association with tobacco smoking exacerbated hypertrophy and in vitro myocardial dysfunction. This is first study to show that the association of an aerobic exercise training with tobacco smoking intensifies the phenotype of pathological cardiac hypertrophy. Therefore, the combination of interventions resulted in exacerbated myocardial hypertrophy and contractility dysfunction. These

  8. Assessment of residual tissue viability by exercise testing in recent myocardial infarction: comparison of the electrocardiogram and myocardial perfusion scintigraphy.

    Science.gov (United States)

    Margonato, A; Ballarotto, C; Bonetti, F; Cappelletti, A; Sciammarella, M; Cianflone, D; Chierchia, S L

    1992-04-01

    The assessment of residual myocardial viability in infarcted areas is relevant for subsequent management and prognosis but requires expensive technology. To evaluate the possibility that simple, easily obtainable clinical markers may detect the presence of within-infarct viable tissue, the significance of exercise-induced ST elevation occurring in leads exploring the area of a recent Q wave myocardial infarction was assessed. Twenty-five patients with recent (less than 6 months) myocardial infarction were studied. All had angiographically documented coronary artery disease, diagnostic Q waves (n = 24) or negative T waves (n = 25) on the rest 12-lead electrocardiogram and exhibited during exercise greater than or equal to 1.5 mm ST segment elevation (n = 17) or isolated T wave pseudonormalization (n = 8) in the infarct-related leads. ST-T wave changes were reproduced in all patients during thallium-201 exercise myocardial scintigraphy. A fixed perfusion defect was observed in 24 of the 25 patients. A reversible defect was seen in 16 (94%) of 17 patients who exhibited transient ST elevation during exercise but in only 4 (50%) of the 8 patients who had only T wave pseudonormalization. In conclusion, in patients with recent myocardial infarction, analysis of simple ST segment variables obtained during exercise testing may allow a first-line discrimination of those who may potentially benefit from a revascularization procedure.

  9. Quantitative evaluation of right ventricular overload in cor pulmonale using sup 201 Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroshi; Misawa, Toshihiro; Kutsumi, Yasunori [Fukui Medical School, Matsuoka (Japan); and others

    1991-01-01

    To determine quantitatively the discriminant and characteristics of cor pulmonale, {sup 201}Tl myocardial perfusion SPECT was performed in 16 patients with chronic obstructive pulmonary disease (COPD) and 7 with restrictive pulmonary disease (RPD). One section of the short-axis SPECT image in which the right ventricle was most clearly visualized was selected. Tl-score was defined as the ratio of the sum of counts in the region of interest (ROI) at the anterior, mid, and posterior regions of the right ventricular free wall to the sum of counts in ROI at the posterior, lateral, and anterior walls of the left ventricle, and the anterior and posterior regions of the interventricular septum. In the group of COPD patients, Tl-score was positively correlated with mean pulmonary arterial pressure (mPAP), total pulmonary vascular resistance (TPR), and arterial carbon dioxide tension (PaCO{sub 2}), while it was inversely correlated with arterial oxygen tension (PaO{sub 2}). However, there was no significant correlation between Tl-score and mPAP, TPR, PaCO{sub 2}, and PaO{sub 2} in the group of RPD patients. In assessing pulmonary hypertension as defined by mPAP over 20 mmHg, a Tl-score greater than 0.25 was useful with a sensitivity of 69% and a specificity of 90%. The occurrence of cor pulmonale is a major factor in determining the prognosis of COPD patients. It was concluded that {sup 201}Tl myocardial SPECT is useful for evaluating right ventricular overload quantitatively, as well as for assessing core pulmonale, especially in COPD patients, since the ratio of Tl counts in the right and left ventricles was significantly correlated with right cardiopulmonary hemodynamic parameters. (N.K.).

  10. Myocardial perfusion imaging with Technetium-99m Sestamibi and Thallium-201. Results of the phase III clinical trial

    International Nuclear Information System (INIS)

    Giering, L.; Haber, S.; Joseph, J.L.; Neacy, W.

    1998-01-01

    Full text: Technetium-99m-Sestamibi (MIBI) has been compared to 201 TI and coronary angiography in a large Phase III clinical trial to assess diagnostic accuracy. Exercise and rest planar (P) and SPECT (S) MIBI, and exercise and redistribution thallium-201 studies were performed in 150 healthy volunteers and 396 patients (379 males; mean age 51.3 years). Prior myocardial infarction was present in 50% of the patients. Sensitivity and specificity for angiographically defined cardiovascular diseases - CAD (>70% stenosis) for planar imaging was 90.3% and 81.3% for MIBI and 91.6% and 50.0% for 201 TI. Agreement was 88.7% MIBI and 84.0% for 201 TI. For SPECT imaging, sensitivity and specificity were 95.1% and 46.0% for MIBI and 92.3% and 39.7% for 201 TI. Agreement was 80.0% for MIBI and 76.1% for 201 TI. Tomographic normality rates were 91.4% and 92.9% for MIBI and 201 TI. Agreement for characterisation of defect type by MIBI and 201 TI SPECT was 82.5%. In females, sensitivity was comparable for both agents. Specificity of MIBI planar and SPECT imaging was higher then for 201 TI (P: 90.9% v. 66.7%; S: 76.2% v. 61.9%). The improved imaging characteristics of MIBI results in better diagnostic confidence when interpreting myocardial perfusion studies especially in women and obese patients

  11. Combination of physical exercise and adenosine improves accuracy of automatic calculation of stress LVEF in gated SPECT using QGS software

    International Nuclear Information System (INIS)

    Tehranipour, N.; AL-Nahhas, A.; Towey, D.

    2005-01-01

    Combining exercise and adenosine during the stress phase of myocardial perfusion imaging (MPI) is known to reduce adverse effects and improve image quality. The aim of this study was to assess whether it can also improve the automatic calculation of left ventricular ejection fraction (LVEF) by QGS software package, during the stress phase of Gated SPECT. One hundred patients who had stress Gated SPECT were retrospectively included in this study. Gated data of those who had adenosine only (50 patients = group A) was compared with those obtained in another group of 50 patients who had added bicycle exercise (Group B). All had identical image acquisition protocol using 99mT c-tetrofosmine. Clinical adverse effects, changes in blood pressure (BP), heart rate (HR), and ECG were monitored. Visual assessment of subdiaphragmatic uptake and accuracy of automatic regions of interest (ROI's) drawn by the software were noted. Regions of interest that involved sub-diaphragmatic uptake and resulting in low LVEF were manually adjusted to include the left ventricle only, and the frequency of manual adjustment was noted. No significant difference was noted in age, sex, baseline BP and HR between groups A and B. Adverse effects occurred less often in group B compared to group A (12% vs. 24%, p = 0.118). Maximum HR and BP achieved during stress were significantly higher in group B compared to group A (p 0.025, p = 0.001 respectively). The number of patients who had faulty ROI's and low LVEF, who needed manual adjustment of ROI.s, were higher in group A compared to group B (16% vs. 6%, p = 0.025). The values of LVEF showed significant improvement following manual adjustment of ROI's, increasing from a mean of 19.63 ± 15.96 to 62.13 ± 7.55 (p = 0.0001) and from 17.33 ± 9.5 to 49.67 ± 7.7 (p = 0.0014) in groups A and B respectively. The addition of exercise to adenosine significantly improves the automatic calculation of LVEF by QGS software during Gated SPECT and reduces the need

  12. Reliability of the exercise ECG in detecting silent ischemia in patients with prior myocardial infarction

    International Nuclear Information System (INIS)

    Yamagishi, Takashi; Matsuda, Yasuo; Satoh, Akira

    1991-01-01

    To assess the reliability of the exercise ECG in detecting silent ischemia, ECG results were compared with those of stress-redistribution thallium-201 single-photon emission computed tomography (SPECT) in 116 patients with prior myocardial infarction and in 20 normal subjects used as a control. The left ventricle (LV) was divided into 20 segmental images, which were scored blindly on a 5-point scale. The redistribution score was defined as thallium defect score of exercise subtracted by that of redistribution image and was used as a measure of amount of ischemic but viable myocardium. The upper limit of normal redistribution score (=4.32) was defined as mean+2 standard deviations derived from 20 normal subjects. Of 116 patients, 47 had the redistribution score above the normal range. Twenty-five (53%) of the 47 patients showed positive ECG response. Fourteen (20%) of the 69 patients, who had the normal redistribution score, showed positive ECG response. Thus, the ECG response had a sensitivity of 53% and a specificity of 80% in detecting transient ischemia. Furthermore, the 116 patients were subdivided into 4 groups according to the presence or absence of chest pain and ECG change during exercise. Fourteen patients showed both chest pain and ECG change and all these patients had the redistribution score above the normal range. Twenty-five patients showed ECG change without chest pain and 11 (44%) of the 25 patients had the abnormal redistribution. Three (43%) of 7 patients who showed chest pain without ECG change had the abnormal redistribution score. Of 70 patients who had neither chest pain nor ECG change, 19 (27%) had the redistribution score above the normal range. Thus, limitations exist in detecting silent ischemia by ECG in patients with a prior myocardial infarction, because the ECG response to the exercise test may have a low degree of sensitivity and a high degree of false positive and false negative results in detecting silent ischemia. (author)

  13. Utility of the premature cocked in SPECT of myocardial perfusion with technetium and artery-dilators. Inherent problems and analysis of local preliminary experience

    International Nuclear Information System (INIS)

    Gutierrez, Daniela; Massardo, Teresa; Jaimovich, Rodrigo; Anzoategui, Wilfredo; Guzman, Alfonso; Lavados, Hugo; Alliende, Isabel

    2007-01-01

    Using myocardial perfusion studies, severe coronary artery disease (CAD) with left ventricular dysfunction could be observed through transient cavity dilation and radiopharmaceutical lung uptake increase, described initially with stress 201 Tl. Dipyridamole (DIP) induced ischemia also can diminish systolic function. Delayed post stress left ventricular ejection fraction (FEVI) may not be able to detect this phenomena, depending on the acquisition timing. There are diverse reports and results in this issue. Goal: Evaluate the correlation between left ventricular parameters and ischemia presence in early gated DIP tomography in patients referred for CAD evaluation along to review the new protocol difficulties.Methods: From 158 patients evaluated initially, 31% presenting extra-cardiac activity were excluded due to interference with automatic edge detection. The analyzed group included 109 subjects between 33 and 91 years, mean age 64.3 ± 11.7; 52% women. Thirty of them were known CAD patients; 18 with myocardial infarction and 31 with ischemia in perfusion images. 99m Tc-Sestamibi SPECT was carried out during the 60 min post DIP infusion, using 1 day protocol. Cedars QGS QPS Programs were used to measure LVEF and left ventricular volumes. Diastolic transient ischemic dilation (TID) calculation was performed as well as lung/heart index (LHR). Results: The mean time lapse between DIP injection and acquisition was 27 min (range: 18-43 min). There was not significant difference between DIP and rest LVEF (66.55±17.33% vs 67.58±18.41%) LVEF delta was 1.03±6.72%. There was not correlation observed between measured functional parameters and presence of ischemia, infarction or known CAD. There was clear difference in left ventricular volumes in patients with and without CAD and known myocardial infarction. Conclusion: Nor association between LHR, LVEF delta or TID and ischemia was demonstrated in early post DIP SPECT acquisition using Sestamibi. In addition, significant

  14. Cardiovascular outcomes after pharmacologic stress myocardial perfusion imaging.

    Science.gov (United States)

    Lee, Douglas S; Husain, Mansoor; Wang, Xuesong; Austin, Peter C; Iwanochko, Robert M

    2016-04-01

    While pharmacologic stress single photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) is used for noninvasive evaluation of patients who are unable to perform treadmill exercise, its impact on net reclassification improvement (NRI) of prognosis is unknown. We evaluated the prognostic value of pharmacologic stress MPI for prediction of cardiovascular death or non-fatal myocardial infarction (MI) within 1 year at a single-center, university-based laboratory. We examined continuous and categorical NRI of pharmacologic SPECT-MPI for prediction of outcomes beyond clinical factors alone. Six thousand two hundred forty patients (median age 66 years [IQR 56-74], 3466 men) were studied and followed for 5963 person-years. SPECT-MPI variables associated with increased risk of cardiovascular death or non-fatal MI included summed stress score, stress ST-shift, and post-stress resting left ventricular ejection fraction ≤50%. Compared to a clinical model which included age, sex, cardiovascular disease, risk factors, and medications, model χ(2) (210.5 vs. 281.9, P statistic (0.74 vs. 0.78, P stress score, stress ST-shift and stress resting left ventricular ejection fraction). SPECT-MPI predictors increased continuous NRI by 49.4% (P 3% annualized risk of cardiovascular death or non-fatal MI, yielded a 15.0% improvement in NRI (95% CI 7.6%-27.6%, P stress MPI substantially improved net reclassification of cardiovascular death or MI risk beyond that afforded by clinical factors. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Comparison of myocardial fatty acid metabolism with left ventricular function and perfusion in cardiomyopathies. By 123I-BMIPP SPECT and 99mTc-tetrofosmin electrocardiographically gated SPECT

    International Nuclear Information System (INIS)

    Zhao, Chunlei; Shuke, Noriyuki; Okizaki, Atsutaka

    2003-01-01

    The objective of this study was to investigate myocardial fatty acid metabolism and its relationship with left ventricular (LV) function and perfusion in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM). Thirty-nine patients with cardiomyopathies (58±14 y), comprising 15 DCM and 24 HCM, and 9 age-matched healthy controls were studied with 123 I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99m Tc-tetrofosmin (TF) electrocardiographically gated SPECT. As parameters of myocardial fatty acid metabolism, the heart-to-mediastinum ratio (H/M) and global washout of BMIPP were calculated from early and delayed planar images, while regional BMIPP uptake and washout were calculated from SPECT. In TF study, the H/M (H/M-TF) and LV ejection fraction (LVEF) were calculated as global parameters of perfusion and function, while regional TF uptake and wall thickening index were calculated as regional parameters of perfusion and function using the Quantitative Gated SPECT software. The differences in the parameters and the correlations between the parameters from the 2 studies were investigated by one-way ANOVA and multiple linear regression analysis. BMIPP uptake was decreased (p 0.05), but showed a significant correlation with H/M-TF (p 0.05) but had a significant correlation with regional perfusion (p<0.0001) in DCM. In HCM, regional BMIPP parameters showed significant multiple linear correlations with both regional function (p<0.005) and perfusion (p<0.0001). According to the partial correlation coefficients, delayed regional BMIPP uptake was the most significant factor for predicting regional function in HCM, while early regional BMIPP uptake was the only or the most significant factor for predicting regional perfusion in DCM and HCM, respectively. In DCM, BMIPP uptake and washout could not reflect LV function. In HCM, regional delayed BMIPP uptake might be useful for evaluating regional function. In DCM and HCM, early BMIPP uptake might be

  16. Assessment of Takotsubo (ampulla) cardiomyopathy using 99mTc-tetrofosmin myocardial SPECT. Comparison with acute coronary syndrome

    International Nuclear Information System (INIS)

    Ito, Kazuki; Katoh, Shuji

    2003-01-01

    We assessed Takotsubo (ampulla) cardiomyopathy compared with acute coronary syndrome (ACS) using two-dimensional echocardiography and 99m Tc-tetrofosmin myocardial SPECT. We examined 10 patients with Takotsubo cardiomyopathy and 16 with ACS at the time of emergency admission (acute phase), at three to nine days after the attack (subacute phase) and at one month after the attack (chronic phase). The left ventricle was divided into nine regions on echocardiograms and SPECT images, and the degree of abnormalities in each region was scored in five grades from normal (0) to severely abnormal (4). Coronary angiography revealed total or subtotal occlusion in patients with ACS but no stenotic legions in those with Takotsubo cardiomyopathy. The amount of ST segment elevation (mm) was 7.9±3.4 in patients with Takotsubo cardiomyopathy and 7.3±3.7 in those with ACS (N.S.). Abnormal wall motion scores on echocardiograms were 13.8±4.4, 4.4±3.8 and 1.8±2.3 during the acute, subacute and chronic phases in patients with Takotsubo cardiomyopathy, and 13.9±4.0, 11.7±3.7, 7.6±4.2, respectively in patients with ACS. The value of MB fraction of creatine phosphokinase (IU/l) was 34±23 in patients with Takotsubo cardiomyopathy and 326±98 in those with ACS (p 99m Tc-tetrofosmin myocardial SPECT were 11.4±3.2, 3.2±3.3 and 0.7±1.1 during the acute, subacute and chronic phases respectively, in patients with Takotsubo cardiomyopathy, and 15.8±4.1, 13.5±4.4, 8.2±4.4, respectively, in those with ACS. The numbers of myocardial segments that did not uptake 99m Tc-tetrofosmin during the acute phase were 0.5±0.8 and 3.6±2.8 in patients with Takotsubo cardiomyopathy and ACS, respectively. Impaired coronary microcirculation might be a causative mechanism of Takotsubo cardiomyopathy. (author)

  17. Effect of post-myocardial infarction streptokinase (sk) therapy, on myocardial viability - evaluation with thallium-201 single photon emission computed tomography (TL-201 SPECT)

    International Nuclear Information System (INIS)

    Shaikh, M.S.; Raza, M.; Kayani, A.M.; Fazal, I.

    2011-01-01

    To evaluate the effect of post-myocardial infarction Streptokinase therapy on myocardial viability, employing Thallium-201 single photon emission computed tomography (TL-201 SPECT). Design: Retrospective, experimental study. Place and duration of study: The Nuclear Cardiology Department, Armed Forces Institute of Cardiology / National Institute of Heart Diseases, Rawalpindi, from 1 April, 2009 to 31 October, 2009. Patients and Methods: Male patients, who had suffered from acute myocardial infarction (AMI), in an area supplied by the left anterior descending (LAD) artery, had infarct-related electrocardiogram (ECG) changes and received or did not receive Streptokinase therapy, were included. Those with a normal ECG, or history of revascularisation, or non-ST elevation MI, or more than one MIs, were excluded. The patients were divided into groups 1 (who received Streptokinase) and 2 (who did not receive Streptokinase). Each group contained 42 patients and all underwent scintigraphic viability study through intravenous injection of 3.0 mCi (123 MBq) of TL-201, followed by rest-redistribution SPECT imaging on a dual head, dedicated cardiac gamma camera system (Philips Cardio MD). Emory's cardiac toolbox and AutoQUANT were used for data processing and quantitative estimation of viable myocardium. Empirical scores from 0 to 2 were assigned to each of the scans, in the order of increasing viability, and these were compared across the two groups. Result: Group 1 contained 42 patients (age range = 38 to 80 years, mean = 53.98 +- 11.26 years), in whom empirical viability scoring was done. Score 0 was seen in 2 patients, score 1 was seen in 15 patients and score 2 was seen in 25 patients form this group. Group 2 also contained 42 patients (age range = 38 to 80 years, mean = 56.71 +- 9.05 years), in whom viability score of 0 was seen in 3 patients, score 1 was seen in 11 patients and score 2 was seen in 28 patients form this group. Age difference between the two groups was

  18. Risk assessment after coronary angioplasty with SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    Camilletti, Jorge A.; Erriest, Juan; Mele, Anibal A.

    2007-01-01

    The chest pain can be use for stratifying the risk of the patients after coronary angioplasty. Nevertheless this strategy has shown to have a low accuracy in the detection of restenosis and myocardial ischemia. Aims: To establish the usefulness of the SPECT studies in the risk stratification after the coronary angioplasty. Evaluate the incidence of silent ischemia or symptomatic, and its impact on the prognosis. Method: There were included 107 patients (p) submitted to a gated SPECT between the year of the coronary angioplasty. The analysis of the images was performed according to different scores (SSS, SRS, SDS). These data was correlated with the symptoms of the patients. We define group 1 (G1) as the asymptomatic without ischemia (n 59p), group 2 (G2) as silent ischemia (n = 28p) and group 3 (G3) as symptomatic with ischemia (n = 20p). A clinical follow-up was done in search of events (target vessel revascularization, unstable angina, AMI and death). Results: Significant differences were not observed in the clinical variables between the different groups. The SSS was lower in the G1 compare with G2 and G3 (p 0.0001) and was similar between the last two, p = NS (SSS: G1: 2.2 ± 4.9; G2: 7.6 ± 5.9; G3: 9.5 ± 6.8). The SDS was greater in G3 vs. G1 and G2, p = 0.0001, and greater in G2 vs. G1, p = 0.0001 (SDS: G1: 0; G2: 4.8 ± 3.5; G3: 7.2 ± 6.5). No differences where observed in the SRS between the three groups. In the follow-up the total percentage of events was lesser when compare the G1 with the G2 and G3 (G1: 3.3%; G2 and G3: 18.7%; p 0.02). The percentage of annual events of the G3 symptomatic with ischemia (11.03%) and G2 silent ischemia (4.04%) did not present differences (p 0.7). When the events of the G2 (4.04%) were compared with the G1 (1.24%) we observed a trend to major frequency of events in the G2 (p = 0.6). Conclusions: The presence of myocardial ischemia after coronary angioplasty is a determinant of the prognosis. Nevertheless, the extension

  19. Clinical evaluation of adenosine and exercise stress 99Tcm-MIBI myocardial imaging in detection of myocardial ischemia in patients with untypical chest pain

    International Nuclear Information System (INIS)

    Tian Yueqin; He Zuoxiang; Wang Qi; Hu Fenghuan; Yang Weixian; Qiao Shubing; Liu Xiujie

    2005-01-01

    Objective: To evaluate the value of adenosine and exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial imaging for the diagnosis of myocardial ischemia in patients with untypical chest pain. Methods: Two groups included. Group 1: 67 cases of adenosine 99 Tc m -MIBI myocardial imaging. Group 2: 81 cases of exercise stress 99 Tc m -MIBI myocardial imaging. All of the patients had coronary angiography (CAG). The results of them were compared. Results: 23 out of 67 patients in group 1 had significant coronary stenosis after CAG, 16 showed reversible perfusion abnormalities in adenosine imaging. 41 of 44 patients with normal CAG showed normal adenosine imaging. The sensitivity, specificity and accuracy of adenosine imaging for coronary artery disease detection were 70%, 93% and 85%, respectively. Group 2: 22 out of 31 patients with significant coronany stenosis after CAG showed reversible perfusion abnormalities, 48 of 50 patients with normal CAG showed normal exercise imaging. The sensitivity, specificity and accuracy of exercise imaging for coronary artery disease detection were 71%, 96% and 86%, respectively. Conclusion: Reversible perfusion abnormalities found both in adenosine and exercise stress 99 Tc m -MIBI myocardial imaging were the key point for diagnosis of myocardial ischemia in patients with untypical chest pain. (authors)

  20. Myocardial perfusion in silent myocardial ischemia

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1989-01-01

    To investigate myocardial perfusion in silent myocardial ischemia, we performed exercise stress myocardial tomography with thallium-201 (Tl) in 85 patients with coronary artery disease (CAD). Exercise stress myocardial tomography was obtained both immediately after exercise and three hours later. Patients were classified into two groups according to the presence (Symptomatic Group, n=36) or absence (Silent Group, n=49) of chest pain during exercise stress. Clinical features (age, gender and history of myocardial infarction) and arteriographically determined severity of CAD were the same in both groups. The extent of myocardial ischemia (% Ischemia) estimated by exercise stress myocardial tomography was the same in each group (30±10 % in Silent Group, 28±12 % in Symptomatic Group, NS). The severity of exercise-induced myocardial ischemia was expressed as a minimal value of myocardial Tl washout rate (minimal WOR) of each patient. Although exercise heart rate was identical in both groups, minimal WOR in Silent Group was significantly higher than that of Symptomatic Group (4±10% vs -16±14%, p<0.001). The study in patients who exhibited both silent and symptomatic ischemia showed the same results. These findings suggest that the severity of ischemia is a fundamental factor in determining the presence or absence of pain during exercise induced ischemia. (author)

  1. Paradoxical hypotension during dobutamine infusion for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Erguen, E.L.; Caner, B.; Atalar, E.; Karanfil, A.; Tokgoezoglu, L.

    1998-01-01

    Dobutamine as a predominant beta-1 agonist increases heart rate and myocardial contractility and at sufficient high doses, it also increases systolic blood pressure. This study was undertaken to describe instances of paradoxical hypotension during dobutamine infusion for Tl-201 myocardial perfusion SPECT study and the relationship between scintigraphic findings and hypotension occurred during dobutamine infusion. Methods: In 201 consecutive patients unable to perform adequate exercise, dobutamine Tl-201 myocardial SPECT was performed. Dobutamine was infused starting from 10 μg/kg/min increasing to 40 μ/kg/min. Paradoxical hypotension was defined as a decrease in systolic blood pressure ≥ 20 mmHg compared with baseline study. Paradoxical hypotension was observed in 40 patients (Group A) out of 201 (19.9%) while no significant change in systolic blood pressure was detected in the remaining 161 patients (Group B). Mean maximum fall in systolic blood pressure was 39±18 mmHg (range: 20-90). In 33 of 40 patients (83%) with paradoxical hypotension, scintigraphy was normal compared to 131 (81%) of the remaining 161 patients. In patients of Group A, angiography, echocardiography and tilt table tests were performed in 13, 11 and 6 patients respectively. Nine of 13 angiographic evaluations (69%), 10 of 11 echocardiographic evaluations (91%), all of the tilt table tests were normal. Additionally, all of the patients of Group A were clinically followed up at least 6 months after the myocardial perfusion scintigraphy. None of the patients had a cardiac event except one patient during the follow-up period. Conclusion: Paradoxical hypotension during dobutamine infusion for myocardial scintigraphy is not an uncommon finding and up to 19.9% patients may develop such hypotension. To maximize test safety, precautions should be taken during dobutamine myocardial stress test, since remarkable decrease in systolic blood pressure may occur. Unlike hypotension occurring with exercise

  2. Myocardial perfusion abnormality and chest pain in patients with hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1991-01-01

    To investigate the role of myocardial ischemia in the development of chest pain in patients with hypertrophic cardiomyopathy (HCM), exercise stress (Ex) redistribution myocardial single photon emission CT's (SPECT's) with thallium-201 (Tl) were obtained in 27 patients with HCM. In all patients, coronary arteries were normal arteriographically. Patients were classified into NYHA Class I, II and III according to the frequency and severity of the chest pain during daily life. In these 3 groups, age, sex and intraventricular septal thickness measured by echocardiography were not different. Types of myocardial perfusion obtained by myocardial SPECT's were divided into 5: (1) normal perfusion, (2) no perfusion defect with abnormal myocardial Tl washout rate (WOR) during 3 hours (<30%) [Def(-)/WORabn], (3) reversible perfusion defect (RD), (4) fixed defect with abnormal WOR (FD/WORabn), and (5) fixed defect with normal WOR (FD/WORnl). In 14 patients of Class I, 9 patients (64%) showed normal perfusion but the rest showed perfusion abnormality (def(-)/WORabn in 3 and RD in 2). In Class II and III, all patients showed perfusion abnormalities of RD, FD/WORabn or FD/WORnl. As the functional class progressed from Class II to III, the ratio of fixed defect (both WORnl and WORabn) to RD increased, but it was not statistically significant. In 2 patients in whom Ex SPECT's were repeated because of the progression of the chest pain, the severity of the perfusion abnormality also progressed. Perfusion abnormalities were observed most frequently in anterior (35%), then inferior/posterior (20%) and septal wall (18%). The frequency of Ex induced ECG abnormalities (ST-depression or T wave changes) increased as the NYHA Class progressed (Class III vs I p<0.05). These findings suggested the following: chest pain in patients with HCM relates to the myocardial ischemia which may originate in the myocardial small arteries, and when the lesions progress myocardial necrosis may ensue. (author)

  3. Myocardial performance and perfusion during exercise in patients with coronary artery disease caused by Kawasaki disease

    International Nuclear Information System (INIS)

    Paridon, S.M.; Ross, R.D.; Kuhns, L.R.; Pinsky, W.W.

    1990-01-01

    For a study of the natural history of coronary artery lesions after Kawasaki disease and their effect on myocardial blood flow reserve with exercise, five such patients underwent exercise testing on a bicycle. Oxygen consumption, carbon dioxide production, minute ventilation, and electrocardiograms were monitored continuously. Thallium-201 scintigraphy was performed for all patients. One patient stopped exercise before exhaustion of cardiovascular reserve but had no evidence of myocardial perfusion abnormalities. Four patients terminated exercise because of exhaustion of cardiovascular reserve; one had normal cardiovascular reserve and thallium scintiscans, but the remaining patients had diminished cardiovascular reserve. Thallium scintigrams showed myocardial ischemia in two and infarction in one. No patient had exercise-induced electrocardiographic changes. These results indicate that patients with residual coronary artery lesions after Kawasaki disease frequently have reduced cardiovascular reserve during exercise. The addition of thallium scintigraphy and metabolic measurements to exercise testing improved the detection of exercise-induced abnormalities of myocardial perfusion

  4. The value of regional wall motion abnormalities on 99Tcm-MIBI gated cardiac SPECT in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Zhu Tiebing; Wang Liansheng; Yang Zhijian; Feng Jianlin; Li Jianhua; Chen Jianwei; Chang Guojun

    2004-01-01

    Objective: To determine the magnitude of angiographic stenoses of coronary artery in reversible regional wall motion abnormalities (RWMA) present in exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) gated SPECT myocardial perfusion imaging (MPI). Methods: One hundred and sixteen patients undergoing coronary angiography two weeks before and after the exercise stress 99 Tc m -MIBI gated SPECT MPI. Images were acquired 15 to 20 min after stress. A five grades and twenty segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 65%, with a specificity of 97%. Reversible RWMA has a high positive predictive value (98%) for stratification between severe angiographic stenoses of 75% and non-severe stenoses (less than 75%). Multivariate analysis showed that the post-stress wall motion (SSSWM), exercise wall motion differentiation value (SDSWM) and summed stress score (SSS) were the independent risk factor of coronary artery jeopardy score. Conclusions: Reversible RWMA, as shown by exercise stress 99 Tc m -MIBI gated SPECT MPI, is a significant predictor of angiographic disease with very high specificity and positive predictive values. Exercise reversible RWMA can rise the assessment value of angiographic severity in MPI

  5. Impairment of myocardial perfusion in children with sickle cell disease; Alteration de la perfusion myocardique chez l'enfant drepanocytaire

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, C. [Hopital Necker-Enfants-Malades, Service de Medecine Nucleaire, 75 - Paris (France); Acar, P. [Centre Hospitalier Universitaire, Hopital des Enfants, Service de Cardiologie Pediatrique, 31 - Toulouse (France); Montalembert, M. de [Hopital Necker-Enfants-Malades, Service de Pediatrie Generale, 75 - Paris (France)

    2003-10-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 {+-} 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 {+-} 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  6. Myocardial perfusion and left ventricular function during exercise evaluated by 201Tl myocardial scintigraphy and 99mTc radionuclide ventriculography in patients treated with PTCA

    International Nuclear Information System (INIS)

    Honda, Toshio; Jo, Tadafumi; Doiuchi, Junji

    1992-01-01

    To evaluate the effects of percutaneous transluminal coronary angioplasty (PTCA), we investigated myocardial ischemia and left ventricular function during exercise before and after successful PTCA in 30 patients. We used extent and severity scores of 201 thallium ( 201 Tl) exercise myocardial scintigraphy to assess myocardial ischemia and determined global and regional left ventricular ejection fraction (EF and REF) of 99m Tc-RBC exercise radionuclide ventriculography to assess left ventricular function. The extent and severity scores of stress images were significantly less after PTCA than before PTCA. The scores of the redistribution images were unchanged before and after PTCA. Global EF during exercise was significantly higher after PTCA than before PTCA. There was no difference in resting global EF between before and after PTCA. Myocardial ischemia induced by exercise was semi-quantitatively analyzed as transient perfusion defect with severity score. Severity score was significantly less after PTCA than before PTCA. ΔEF, which was obtained by subtraction of resting global EF from exercise one, was significantly higher after PTCA than before PTCA. However, the degree of improvement in myocardial ischemia and left ventricular function varied from patient to patient. In 17 patients with one-vessel left anterior descending artery disease, ΔREF, which was determined by subtracting resting regional EF from exercise one, was significantly higher in septal and apical segments after PTCA than before PTCA. Myocardial ischemia and left ventricular function under exercise were alleviated by PTCA. However, the degree of improvement varied from patient to patient and it might have been affected by various factors including coronary dissection, edema, thrombus, restenosis, spasm, side branch stenosis or occlusion, distal thrombus, and myocardial hibernation. (author)

  7. Is attenuation correction of myocardial SPECT scans worth the effort?

    International Nuclear Information System (INIS)

    Bui, C.; Nguyen, D.; Dixson, H.; Saunders, C.; Cook, P.; Burnett, P.; Croll, F.; Dunn, R.; Hasche, E.; Kelleher, P.; Nasser, F.; Wilson, D.; Lee, K.

    2000-01-01

    Full text: Gated (GS), attenuation-corrected (AC) and non-attenuation-corrected (NAC) myocardial SPECT scans were performed after injection of 99 Tc m -Sestamibi (MIBI) at peak stress in 253 patients between September 1998 and March 1999. 60 patients have undergone cardiac catheterisation (37 males, 23 females, age range 34-80). For whole heart analysis, significant coronary disease was defined as 50% or greater diameter narrowing in any of the coronary arteries and/or documented myocardial infarction. For vascular territory analysis, significant coronary disease was defined as 50% or greater diameter narrowing of any artery in that territory. The three coronary artery territories were assigned as: left anterior descending (LAD), left circumflex (LCA) and right coronary (RCA). The septum, apex and anterior wall; the lateral wall; and the inferior wall were assigned to the LAD; LCA; and RCA territories respectively. In conclusion for this selected subgroup of patients with angiographic follow-up, NAC, AC and GS were of similar accuracy in the detection of significant CAD in both whole heart analysis and individual vascular territory analysis. AC and GS were of superior specificity when compared with NAC in both whole heart analysis and individual vascular territory analysis. AC and GS may be of additional diagnostic value in improving the specificity of NAC. Further outcome data will be presented. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  8. Triple vessel coronary artery disease presenting as a markedly positive stress electrocardiographic test and a negative SPECT-TL scintigram: a case of balanced Ischemia

    Directory of Open Access Journals (Sweden)

    Eyal Herzog

    2011-09-01

    Full Text Available The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. We present a case of an 81- year old post-menopausal female who presented to her primary care physician for evaluation of a 6-week dyspnea on exertion and was referred to our institution for exercise stress test with Thallium SPECT with the objective of ruling out coronary artery disease and identifying possible areas of myocardial ischemia. The resting electrocardiogram was unremarkable and stress test evaluation was made. The patient was admitted to the cardiac care unit and coronary artery bypass grafting was successfully performed. The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. Patients undergoing stress tests with these characteristics should undergo careful evaluation and a high level of suspicion should be adopted for further diagnostic assessment of coronary artery disease.

  9. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  10. Regional wall thickening in gated myocardial perfusion SPECT in a Japanese population: effect of sex, radiotracer, rotation angles and frame rates

    Energy Technology Data Exchange (ETDEWEB)

    Akhter, Nasima; Nakajima, Kenichi; Okuda, Koichi; Matsuo, Shinro; Yoneyama, Tatsuya; Taki, Junichi; Kinuya, Seigo [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa, Ishikawa (Japan)

    2008-09-15

    Gated single-photon emission computed tomography (SPECT) imaging of myocardium by {sup 99m}Tc and {sup 201}Tl is used extensively to measure quantitative cardiac functional parameters. However, factors affecting normal values for myocardial functional parameters and population-specific standards have not yet been established. The aim of the study was to determine the effect of sex, radiotracer, rotation angles and frame rates on resting myocardial wall thickening (WT) and to develop a Japanese standard of normal values for WT. Data from a total of 202 patients with low possibility of having cardiac problems were collected from nine hospitals throughout Japan. Patients were divided into five groups according to study protocol, and WT was evaluated according to the 17-segment and four-region (basal, mid and apical regions and the apex) polar map distribution. WT was generally higher in women than in men irrespective of the use of radiotracers, rotation angles or frame rates, and the difference was highly significant in the mid and apical regions. In any protocol used, resting myocardial thickening in the apex was higher than in the mid and apical regions, and thickening was lowest in the basal region, suggesting heterogeneous regional myocardial thickening (%) in normal subjects. Different rotation angles showed no significant change on WT, but different frame rates and tracers showed significant WT change in both sexes. Percent thickening of the myocardium was significantly higher in imaging by {sup 99m}Tc-labelled tracers than in {sup 201}Tl. Sex, radiotracers and frame rates had a significant effect on myocardial thickening, and the importance of population-specific standards should be emphasized. A normal database can serve as a standard for gated SPECT evaluation of myocardial thickening in a Japanese population and might be applicable to Asian populations having a similar physique. (orig.)

  11. Myocardial scintigraphy (thallium-201) and electrocardiography at rest and during exercise in angina pectoris

    International Nuclear Information System (INIS)

    Minning, E.; Scharf-Bornhofen, E.; Brueggeman, Th.; Chen, T.; Barthel, W.; Bluemchen, G.; Sankt-Josef-Hospital, Oberhausen

    1980-01-01

    Ecg (at rest and during exercise) was compared to Thallium-201 myocardial perfusion imaging (at rest and after exercise) in 65 patients with coronary heart disease (myocardial infarction in 53 patients) and angina pectoris. These results were compared to coronary angiography and left ventricular angiography. (orig./AJ) [de

  12. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Chia-Ju Liu

    Full Text Available Myocardial perfusion imaging (MPI using gated single-photon emission tomography (gSPECT may underestimate the severity of coronary artery disease (CAD. This study aimed to evaluate the significance of combined parameters derived from gSPECT, as well as treadmill stress test parameters, in the detection of severe CAD.A total of 211 consecutive patients referred for exercise MPI between June 2011 and June 2013 (who received invasive coronary angiography within six months after MPI were retrospectively reviewed. Exercise MPI was performed with Bruce protocol and 201Tl injected at peak exercise. Gated SPECT was performed using a cadmium-zinc-telluride camera and processed by QPS/QGS software. Perfusion defect abnormalities such as sum stress score (SSS; sum difference score, algorithm-derived total perfusion deficits, transient ischemic dilatation ratios of end-diastolic volumes and end-systolic volumes, post-stress changes in ejection fraction, and lung/heart ratio (LHR were calculated. Treadmill parameters, including ST depression (STD at the 1st and 3rd minutes of recovery stage (1'STD and 3'STD, maximal STD corrected by heart rate increment (ST/HR, heart rate decline in 1st and 3rd minutes of recovery stage, recovery heart rate ratio (HR ratio, systolic and mean blood pressure ratios (SBP ratio and MAP ratio during recovery phase were recorded. Diagnostic performances of these parameters were analyzed with receiver operating characteristic (ROC analysis and logistic regression for detection of left main (≥ 50% or 3-vessel disease (all ≥ 70% luminal stenosis on invasive angiography.Among various MPI and treadmill parameters used for detection of severe CAD, SSS and ST/HR had the highest AUC (0.78, 0.73, p = NS and best cut-off values (SSS > 6, ST/HR > 17.39 10-2mV/bpm, respectively. By univariate logistic regression, all parameters except 1'HRR, 3'HRR, SBP and MAP ratios increased the odds ratio of severe CAD. Only increased L/H ratio, 3'STD

  13. Diagnostic Value of Myocardial Perfusion SPECT with Dipyridamole in a Female Population

    International Nuclear Information System (INIS)

    Perez-Iruela, Juan; Pastor, Purificacion; Lumbreras, Luis; Martin, Ana M.; Ruiz, Francisco J.; Posadas, A.; Puentes, Carmen

    2009-01-01

    Background: Exercise stress scintigraphy is a safe procedure widely used for the diagnosis of ischemic heart disease. Pharmacologic stress testing is an important alternative. The delayed presentation of ischemic heart disease in women, together with a lower diagnostic accuracy of exercise stress testing in this population, has generated interest in the potential benefits provided by myocardial perfusion imaging tests. Objective: To determine the diagnostic value of myocardial perfusion images with 99m Tc-tetrofosmin in a one day protocol after a pharmacologic stress with dipyridamole in a female population, and the relation with the coronary territories using coronary angiography as a reference technique. Material and Methods: In total, 149 clinical charts of women with suspected ischemic heart disease undergoing myocardial perfusion imaging tests and coronary angiography were retrospectively analyzed. Results: Sensitivity and specificity were 94% (93.47%-94.53%) and 82% (80.94%-83.06%), respectively. Values of sensitivity and specificity according to coronary territories were 71.62% (70.88%-72.36%) and 76% (75.27%-76.73%) for the left anterior descending (LAD) artery, 69.09% (68.11%-70.07%) and 76.84% (76.26%-77.42%) for the left circumflex (LCx) coronary artery, and 87.23% (86.11%-88.36%) and 74.51% (73.97%-75.05%) for the right coronary artery (RCA), respectively. Conclusion: Myocardial perfusion scintigraphy with 99m Tc-tetrofosmin and dipyridamole using a one day stress-rest protocol has high sensitivity and specificity for the diagnosis of ischemic heart disease in women. (authors) [es

  14. Evaluation of the effects of rehabilitation exercise on cerebral infarction with 99Tcm-ECD SPECT brain imaging

    International Nuclear Information System (INIS)

    Jiang Ningyi; Lu Xianping; Liu Xingguang; Xiao Xiuhong; Xu Jianxing

    2003-01-01

    Objective: To investigate the therapeutic effects of motor therapy on hemiplegia with SPECT brain perfusion imaging. Methods: The study population consisted of 59 patients with cerebral infarction, and all patients were treated with motor therapy. Among them, 30 cases were assigned to undertake single bridging exercise and 29 cases passive exercise. SPECT brain perfusion imaging was performed before and after motor therapy under the same condition, and the regional cerebral blood flow (rCBF) changes were compared and analysed with visual and semi-quantitative methods; in addition, the relationship between rCBF changes and scores of Fugl-Meyer or Barthel index were also analysed. Results: After motor therapy, various degrees of radioactivity increase were compared with the pretreatment radioactivity hypoperfusion in patients with cerebral infarction, and showed that motor therapy could evidently improve rCBF of regional hypoperfusion. The posttreatment rCBF was higher than the pretreatment level (P<0.01), and the rCBF of group of single bridging was higher than that of passive exercise group. And the changes of rCBF were all significant after motor therapy. In addition, the variation of the rCBF after motor therapy was positively correlated with the variation of Fugl-Meyer and Barthel score. Conclusions: SPECT brain perfusion imaging can serve as a useful method for evaluating the effectiveness of motor therapy in cerebral infarction rehabilitation. The single bridging exercise and the passive exercise are both beneficial to brain rehabilitation, but the former improves the rCBF in lesions better than the later does

  15. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-β-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Shimoyama, Katsuya

    1999-01-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using 123 I-β-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and 201 thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  16. Assessment of myocardial viability by exercise stress myocardial tomography with 201Tl

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1992-01-01

    Exercise stress (Ex) and redistribution (RD) myocardial tomography with Tl-201 has been widely used for evaluating myocardial viability. But recent studies have demonstrated that reinjection (ReI) study following RD study is necessary for detecting reversible ischemic myocardium. On the other hand, decreased myocardial washout of Tl-201 after Ex is an indicator of myocardial ischemia. So we have studied the usefulness of myocardial Tl-201 washout rate (WOR) for the evaluation of myocardial viability by comparing it with ReI images. Ex and RD myocardial tomographies were obtained immediately after Ex and 3 hours later. After RD study a small amount of Tl-201 was injected and ReI imaging was repeated. We studied 64 myocardial segments (in 58 patients with coronary artery disease) in which Ex-induced perfusion defects persisted in RD images. According to the changes of perfusion defects between Ex, RD and ReI images, they were classified into 3 types: Type I; perfusion defect on the RD image was identical to ReI image (75%). Type I was divided into 2 subgroups whether perfusion defect at Ex was unchanged (Ia, 42%) or improved (Ib, 33%) on the RD image. Type II; perfusion defect at Ex was reduced on the RD image and it improved furthermore at ReI image (17%). Type III; perfusion defect was the same at Ex and RD but it was reduced on the ReI image (8%). WOR less than 30% was defined as abnormal when Ex heart rate exceeded 120 bpm and lung-myocardial Tl-201 uptake ratio was less than 0.45. The differentiation between Type Ia and Type III is of great importance. History of myocardial infarction, effort angina and Ex induced ST depression could not differentiate these 2 groups. WOR abnormality was observed in all of Type III, but WOR was normal in Type Ia. In conclusion, WOR abnormality in Ex-RD myocardial imaging is useful for evaluating myocardial viability. ReI imaging is necessary for the precise evaluation of viable muscle mass and for inadequate Ex. (author)

  17. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Feng, Jianlin; Zhou, Yanli; Cao, Kejiang; Lloyd, Michael S; Chen, Ji

    2012-07-01

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4%) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI.

  18. The effects of hypoxemia on myocardial blood flow during exercise.

    Science.gov (United States)

    Paridon, S M; Bricker, J T; Dreyer, W J; Reardon, M; Smith, E O; Porter, C B; Michael, L; Fisher, D J

    1989-03-01

    We evaluated the adequacy of regional and transmural blood flow during exercise and rapid pacing after 1 wk of hypoxemia. Seven mature mongrel dogs were made hypoxemic (mean O2 saturation = 72.4%) by anastomosis of left pulmonary artery to left atrial appendage. Catheters were placed in the left atrium, right atrium, pulmonary artery, and aorta. Atrial and ventricular pacing wires were placed. An aortic flow probe was placed to measure cardiac output. Ten nonshunted dogs, similarly instrumented, served as controls. Recovery time was approximately 1 wk. Cardiac output, mean aortic pressure, and oxygen saturation were measured at rest, with ventricular pacing, atrial pacing, and with treadmill exercise. Ventricular and atrial pace and exercise were at a heart rate of 200. Right ventricular free wall, left ventricular free wall, and septal blood flow were measured with radionuclide-labeled microspheres. Cardiac output, left atrial blood pressure, and aortic blood pressure were similar between the two groups of dogs in all testing states. Myocardial blood flow was significantly higher in the right and left ventricular free wall in the hypoxemic animals during resting and exercise testing states. Myocardial oxygen delivery was similar between the two groups of animals. Pacing resulted in an increase in myocardial blood flow in the control animals but not the hypoxemic animals.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Myocardial metabolic abnormalities in hypertrophic cardiomyopathy assessed by iodine-123-labeled beta-methyl-branched fatty acid myocardial scintigraphy and its relation to exercise-induced ischemia

    International Nuclear Information System (INIS)

    Matsuo, Shinro; Nakamura, Yasuyuki; Takahashi, Masayuki; Mitsunami, Kenichi; Kinoshita, Masahiko

    1998-01-01

    Reversible thallium-201 ( 201 Tl) abnormalities during exercise stress have been used as markers of myocardial ischemia in hypertrophic cardiomyopathy (HCM) and are most likely to identify relatively underperfused myocardium. Although metabolic abnormalities in HCM were reported, the relationship between impaired energy metabolism and exercise-induced ischemia has not been fully elucidated as yet. To assess the relationship between myocardial perfusion abnormalities and fatty acid metabolic abnormalities, 28 patients with HCM underwent exercise 201 Tl and rest 123 I-15-(p-iodophenyl)-3-methyl pentadecanoic acid (BMIPP) scintigraphy. Perfusion abnormalities were observed by exercise 201 Tl in 19/28 patients with HCM. 123 I-BMIPP uptake was decreased compared with delayed 201 Tl in 106/364 (29%) of the total myocardial segments (p 123 I-BMIPP and 201 Tl was observed more often in the 49/75 (65%) segments with reversible exercise 201 Tl defects (p 123 I-BMIPP and 201 Tl suggests that myocardial ischemia may play an important role in metabolic abnormalities in HCM. (author)

  20. Exercise-induced silent myocardial ischemia: Evaluation by thallium-201 emission computed tomography

    International Nuclear Information System (INIS)

    Kurata, C.; Sakata, K.; Taguchi, T.; Kobayashi, A.; Yamazaki, N.

    1990-01-01

    Factors associated with silent myocardial ischemia (SMI) during exercise testing were studied by means of thallium-201 emission computed tomography (ECT) in 471 patients. Coronary angiography was done in 290, of whom 167 were found to have significant coronary artery disease (CAD). Exercise-induced ischemia and its severity were defined with ECT. During exercise 108 (62%) of 173 patients with ischemia and 57 (50%) of 115 with ischemia and angiographically documented CAD had no chest pain. One third of the patients showed an inconsistency between scintigraphic ischemia and ischemia ST depression. Age, sex, prior myocardial infarction, and diabetes mellitus were not related to SMI. Patients with SMI had less severe ischemia despite a higher peak double product compared to those with painful ischemia. Among 91 with prior myocardial infarction and exercise-induced ischemia, 51 with periinfarction ischemia had a higher frequency of SMI than did 14 with ischemia remote from the prior infarct zone despite similarities in the severity of ischemia. In conclusion, factors localized within ischemic myocardium such as less severe ischemia or adjacency to a prior infarct made SMI more prevalent

  1. Determination of optimum filter in myocardial SPECT: A phantom study

    International Nuclear Information System (INIS)

    Takavar, A.; Shamsipour, Gh.; Sohrabi, M.; Eftekhari, M.

    2004-01-01

    Background: In myocardial perfusion SPECT images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. Filters greatly affect quality of nuclear medicine images. Materials and Methods: A phantom simulating heart left ventricle was built. About 1mCi of 99m Tc was injected into the phantom. Images was taken from this phantom. Some filters including Parzen, Hamming, Hanning, Butter worth and Gaussian were exerted on the phantom images. By defining some criteria such as contrast, signal to noise ratio, and defect size detectability, the best filter can be determined. Results: 0.325 Nyquist frequency and 0.5 nq was obtained as the optimum cut off frequencies respectively for hamming and handing filters. Order 11, cut off 0.45 Nq and order 20 cut off 0.5 Nq obtained optimum respectively for Butter worth and Gaussian filters. Conclusion: The optimum member of every filter's family was obtained

  2. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR.

    Science.gov (United States)

    Hippeläinen, Eero; Mäkelä, Teemu; Kaasalainen, Touko; Kaleva, Erna

    2017-12-01

    Developments in single photon emission tomography instrumentation and reconstruction methods present a potential for decreasing acquisition times. One of such recent options for myocardial perfusion imaging (MPI) is IQ-SPECT. This study was motivated by the inconsistency in the reported ejection fraction (EF) and left ventricular (LV) volume results between IQ-SPECT and more conventional low-energy high-resolution (LEHR) collimation protocols. IQ-SPECT and LEHR quantitative results were compared while the equivalent number of iterations (EI) was varied. The end-diastolic (EDV) and end-systolic volumes (ESV) and the derived EF values were investigated. A dynamic heart phantom was used to produce repeatable ESVs, EDVs and EFs. Phantom performance was verified by comparing the set EF values to those measured from a gated multi-slice X-ray computed tomography (CT) scan (EF True ). The phantom with an EF setting of 45, 55, 65 and 70% was imaged with both IQ-SPECT and LEHR protocols. The data were reconstructed with different EI, and two commonly used clinical myocardium delineation software were used to evaluate the LV volumes. The CT verification showed that the phantom EF settings were repeatable and accurate with the EF True being within 1% point from the manufacture's nominal value. Depending on EI both MPI protocols can be made to produce correct EF estimates, but IQ-SPECT protocol produced on average 41 and 42% smaller EDV and ESV when compared to the phantom's volumes, while LEHR protocol underestimated volumes by 24 and 21%, respectively. The volume results were largely similar between the delineation methods used. The reconstruction parameters can greatly affect the volume estimates obtained from perfusion studies. IQ-SPECT produces systematically smaller LV volumes than the conventional LEHR MPI protocol. The volume estimates are also software dependent.

  3. Clinical application of cardiac SPECT

    International Nuclear Information System (INIS)

    Nishimura, Shigeyuki

    1999-01-01

    Single-photon emission computed tomography (SPECT) has replaced planar imaging techniques for myocardial scintigraphy. Thallium-201 was the dominant agent employed for myocardial perfusion imaging. Today new technetium-99m labelled radionuclides have been used as excellent alternatives to 201 Tl for detection of coronary artery disease, prognostification, and even assessment of myocardial viability. Pharmacologic stress imaging using either dipyridamole, adenosine or dobutamine is a substitute for exercise stress. Accurate determination of myocardial viability is vitally important for clinical decision making for patients with LV dysfunction who will most benefit from revascularization. Stunned and hibernated myocardium may result in profound regional LTV dysfunction in absence of necrosis. The various approach such as stress-redistribution-reinjection imaging, rest-redistribution imaging and stress-redistribution-24 hours delayed imaging has been utilized to assess myocardial viability with 201 Tl. Quantitative assessment of 99m Tc MIBI uptake reflect the degree of viability. 123 I-Metaiodobenzylguanidine (MIBG), an analog of norepinephrine, has been used for scintigraphic assessment of regional cardiac adrenergic innervation. Cardiac sympathetic denervation, assessed by 123 I-MIBG, due to ischemia in non-Q myocardial infarction and unstable angina has been shown. Quantitative cardiac MIBG scintigram was shown to have prognostic value in patients with severe congestive heart failure. 23 I-BMIPP (ρ-methyl-iodophenyl pentadecanoic acid) has been used to assess myocardial fatty acid utilization. BMIPP has the memory function of ischemia in unstable angina, since decreased BMIPP uptake persists several days after ischemic episode. Nuclear cardiology in Japan has experienced an expansion in the techniques including use of new radionuclides, 99m Tc perfusion agents, 123 I-MIBG and 23 I-BMIPP and in associated clinical application to the various cardiac diseases

  4. Cardiac events in patients with positive exercise ECG and normal myocardial perfusion scan - a retrospective study

    International Nuclear Information System (INIS)

    Marshman, K.; Thomson, L.E.J.; Rowe, C.C.; Burns, A.J.; Woon, F.S.

    2002-01-01

    Full text: The low risk of future cardiac events following a normal myocardial perfusion study with normal stress ECG has been well documented. However, there is little literature regarding the prognosis in patients with a positive stress ECG (PosETT) and normal myocardial perfusion scan (MPS). A search of our database over an eighteen month period identified 21 patients who fitted study criteria. A PosETT was defined as stress induced horizontal or downsloping ST depression > 1mm in one or more leads with a normal baseline 12 lead ECG. Patients were divided into two subgroups depending on the severity of ST depression. A mildly PosETT was defined as ST depression of 1-1.5mm (n=10) and strongly PosETT was defined as ST depression of >2mm in at least one lead with depression in other leads (n=l 1). A normal MPS was defined as absence of reversible perfusion defects on SPECT imaging. Technetium 99m Tetrofosmin was the imaging agent used in 18/21 patients. All 21 patients exercised using the Bruce protocol for 3-12 minutes, and 9 experienced chest pain 12 months after the MPS, referring physicians were contacted. Cardiac events were defined as cardiac death, myocardial infarction, unstable angina, cardiac failure, revascularisation or a coronary angiogram demonstrating >70% stenosis. To date, follow up is complete in 11 patients with one confirmed case of single vessel revascularisation 3 months post MPS. Full follow up data will be presented. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Potential diagnostic value of regional myocardial adrenergic imaging using {sup 123}I-MIBG SPECT to identify patients with Lewy body diseases

    Energy Technology Data Exchange (ETDEWEB)

    Lebasnier, Adrien; Peyronnet, Damien; Bouvard, Gerard [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Lamotte, Guillaume; Defer, Gilles [University Hospital Center of Caen, Department of Neurology, Caen (France); Manrique, Alain [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Cyceron PET Centre, Caen (France); Normandie Universite, Caen (France); Agostini, Denis [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Normandie Universite, Caen (France)

    2015-01-28

    The aim of this study was to determine the potential diagnostic value of regional myocardial adrenergic {sup 123}I-metaiodobenzylguanidine (MIBG) single photon emission computed tomography (SPECT) imaging to identify patients with Lewy body diseases (LBD+). Sixty-four consecutive patients who underwent cardiac {sup 123}I-MIBG SPECT to differentiate LBD+, including Parkinson's disease (PD) and dementia with Lewy bodies (DLB), from patients without LBD (LBD-) were retrospectively reviewed. A neurologist expert in memory disorders determined the final clinical diagnosis by using international clinical diagnostic criteria. Planar [heart to mediastinum ratio (HMR)] and {sup 123}I-MIBG SPECT[innervation defect score (IDS)] using the 17-segment left ventricular model (five-point scale) were obtained 4 h after the injection of {sup 123}I-MIBG on a low-energy high-resolution (LEHR) collimator. Receiver-operating characteristic (ROC) analysis was performed to determine the optimal HMR and IDS cut-off values to discriminate LBD+ from LBD-. Of the 64 patients, 45 (70 %) were diagnosed LBD+ (DLB, n = 27; PD, n = 18) and 19 were diagnosed LBD- (5 other dementias, 14 other parkinsonisms). The HMR and IDS of LBD+ were significantly different from those of LBD- (1.30 ± 0.21 vs 1.65 ± 0.26, p < 0.001; 39 ± 28 vs 8 ± 16, p = 0.001). The optimal HMR and IDS cut-off values to discriminate LBD+ (n = 45) from LBD- (n = 19) were 1.47 and 6/68, providing a sensitivity and specificity of 82.2 and 84.2 % and 86.7 and 73.7 %, respectively. Regional myocardial adrenergic {sup 123}I-MIBG imaging SPECT has a potential diagnostic value to identify LBD+. (orig.)

  6. Prognostic value of Tc-99m tetrofosmin myocardial perfusion gated SPECT in patients with diabetes mellitus and suspected coronary artery disease

    International Nuclear Information System (INIS)

    Santos, Marcia Maria Sales dos; Pantoja, Mauricio da Rocha; Cwajg, Eduardo

    2008-01-01

    Background: The cardiovascular disease is the main cause of death among diabetic patients, which makes it crucial to identify the individuals at higher risk of cardiovascular events. Objective: To evaluate the prognostic value of scintigraphy with gated single photon emission computed tomography (SPECT) in patients with diabetes mellitus (DM) and suspected coronary artery disease. Methods: Retrospective study with 232 diabetic patients submitted to scintigraphy with gated SPECT. Perfusion Gated SPECT (scores and number of altered segments) as well as ventricular function parameters (ejection fraction, left ventricle volume and contractility) were evaluated. Cardiac death, acute ischemic coronary syndrome, revascularization procedures or encephalic vascular accident were considered future cardiovascular events. The uni- and multivariate analyses were carried out by the multiple logistic regression model (p< 0.05). Results: At the univariate analysis, age (p=0.02), chest angina (p=0.01), insulin therapy (p=0.02), myocardial perfusion abnormalities (p<0.0001), the number of segments involved (p=0.0001), the perfusion scores (p=0.0001), the ejection fraction (p=0.004), the final systolic volume (p=0.03) and the finding of segmental alteration at the LV contractility (p<0.0001) were associated with future events at the univariate analysis. At the multivariate analysis, the male sex (p=0.007), age (p=0.03), angina (p=0.001), insulin therapy (p=0.007) and the SDS ≥ 3 (p=0.0001), and the number of altered segments ≥ 3 (p=0.0001) were predictors of cardiovascular events. Conclusion: The myocardial scintigraphy with gated SPECT adds independent information to the stratification of the risk of future cardiovascular events in patients with DM and suspected coronary artery disease. (author)

  7. Prognostic value of Tc-99m tetrofosmin myocardial perfusion gated SPECT in patients with diabetes mellitus and suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia Maria Sales dos; Pantoja, Mauricio da Rocha; Cwajg, Eduardo [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); CINTILAB, Rio de Janeiro, RJ (Brazil); E-mail: mmsales@oi.com.br

    2008-01-15

    Background: The cardiovascular disease is the main cause of death among diabetic patients, which makes it crucial to identify the individuals at higher risk of cardiovascular events. Objective: To evaluate the prognostic value of scintigraphy with gated single photon emission computed tomography (SPECT) in patients with diabetes mellitus (DM) and suspected coronary artery disease. Methods: Retrospective study with 232 diabetic patients submitted to scintigraphy with gated SPECT. Perfusion Gated SPECT (scores and number of altered segments) as well as ventricular function parameters (ejection fraction, left ventricle volume and contractility) were evaluated. Cardiac death, acute ischemic coronary syndrome, revascularization procedures or encephalic vascular accident were considered future cardiovascular events. The uni- and multivariate analyses were carried out by the multiple logistic regression model (p< 0.05). Results: At the univariate analysis, age (p=0.02), chest angina (p=0.01), insulin therapy (p=0.02), myocardial perfusion abnormalities (p<0.0001), the number of segments involved (p=0.0001), the perfusion scores (p=0.0001), the ejection fraction (p=0.004), the final systolic volume (p=0.03) and the finding of segmental alteration at the LV contractility (p<0.0001) were associated with future events at the univariate analysis. At the multivariate analysis, the male sex (p=0.007), age (p=0.03), angina (p=0.001), insulin therapy (p=0.007) and the SDS {>=} 3 (p=0.0001), and the number of altered segments {>=} 3 (p=0.0001) were predictors of cardiovascular events. Conclusion: The myocardial scintigraphy with gated SPECT adds independent information to the stratification of the risk of future cardiovascular events in patients with DM and suspected coronary artery disease. (author)

  8. Comparative study of adenosine and exercise 201Tl myocardial perfusion tomographic imaging for detection of coronary heart disease

    International Nuclear Information System (INIS)

    Wang Xiong

    1997-01-01

    To compare diagnostic accuracy of adenosine and exercise 201 Tl myocardial perfusion tomographic imaging for detection of coronary heart disease (CHD) in patients with a normal rest ECG and no history of myocardial infarction, 81 patients with CHD and 10 normal control subjects underwent adenosine myocardial perfusion imaging, exercise nuclide myocardial perfusion imaging was performed in 117 patients with CHD and 16 normal control subjects, two groups also had coronary arteriography. Both exercise and adenosine testing parameters were analysed. It is shown: 1) The sensitivity and specificity for detection of CHD were 79% vs 80% for adenosine group and 81% vs 81% for exercise myocardial perfusion imaging group respectively. There was no significant difference in comparison with two matched groups (χ 2 = 1.13, χ 2 = 0.18, χ 2 = 0.12, P>0.05). 2) Side effects induced by adenosine accounted for 89% of patients, all symptoms were mild and disappeared quickly after the termination of the study except in 2 cases withdrawal of infusion needed because of severe angina pectoris. Adenosine myocardial perfusion imaging is a safe and sensitive method for detection of CHD. The diagnostic value of adenosine test is similar to that of exercise myocardial perfusion imaging and particularly useful in evaluating patients unable to perform exercise test or achieve adequate level of exercise

  9. Prevalence of silent myocardial ischaemia during exercise stress testing. Its relation to effort tolerance and myocardial perfusion abnormalities.

    Science.gov (United States)

    Fragasso, G; Sciammarella, M G; Rossetti, E E; Xuereb, R G; Xuereb, M; Bonetti, F; Carandente, O M; Margonato, A; Chierchia, S L

    1992-07-01

    The number of underperfused myocardial segments, the extent of coronary artery disease and the severity of impairment of coronary flow reserve were compared in 147 consecutive patients exhibiting painful or painless ischaemic ST segment depression on exercise testing. Of 147 patients, only 61 (41%) experienced angina (group 1) whilst 86 (59%) did not (group 2). In the two groups coronary disease was comparable for both extent and distribution, and neither the location of transient perfusion defects nor their relation to areas of old myocardial necrosis appeared to influence the presence or absence of chest pain. However, exercise duration, exercise time and rate-pressure product at the beginning of ischaemia were lower in group 1. Furthermore, a greater proportion of asymptomatic patients had only one ischaemic segment on 99mTc-MIBI perfusion scintigraphy. We conclude that: (1) in patients with effort angina and coronary disease, the incidence of electrocardiographic silent ischaemic events induced by exercise is similar to that observed in studies based on continuous ECG monitoring. (2) Exertional angina is more frequently associated with greater ischaemic areas and with more severe degrees of impairment of residual coronary flow reserve. (3) The presence of an old myocardial infarction does not appear to influence the incidence of ischaemic cardiac pain.

  10. Effect of collateral circulation on myocardial protection in patients with acute myocardial infarction. Comparison of technetium-99m-tetrofosmin myocardial single photon emission computed tomography and coronary angiography

    International Nuclear Information System (INIS)

    Yoshida, Michi; Kondo, Makoto; Abe, Yoshiteru; Kubota, Tomoyuki; Matsuoka, Ryota; Araki, Makoto; Tanio, Hitoshi; Doyama, Kiyoshi

    2006-01-01

    Evaluation of myocardial blood flow from collateral vessels into the infarct area has been estimated by coronary angiography. In patients with acute myocardial infarction with Thrombolysis in Myocardial Infarction (TIMI) 0 flow, myocardial tracer uptake on single photon emission computed tomography (SPECT) images can predict the collateral blood flow in the infarct area if technetium (Tc)-99m-tetrofosmin was administered before recanalization. The present study investigated whether collateral blood flow evaluated by myocardial scintigraphy is a good predictor of myocardial salvage in patients with acute myocardial infarction. The study group consisted of 30 patients (mean age 65±14 years, 23 males, 7 females) with first acute myocardial infarction and coronary angiography evidence of total occlusion (TIMI 0) within 12 hr after the onset. All patients had one vessel disease related to infarction and TIMI 3 flow after percutaneous coronary intervention (PCI). Tc-99m-tetrofosmin was injected intravenously before the PCI. The regional severity score index (RSSI) was obtained from SPECT using the 17 segment method with the four-point scoring system. Myocardial viability was evaluated by the RSSI obtained from thallium-glucose-insulin infusion SPECT after 1 week and regional wall motion score index obtained from echocardiography during the chronic phase. The patients were divided into two groups according to the angiographic collateral finding. There were no differences in RSSI on thallium-glucose-insulin SPECT and regional wall motion score between the good collateral group (n=8) and poor collateral group (n=22). Myocardial Tc-99m-tetrofosmin RSSI was similar in these groups. On the other hand, the patients were divided according to Tc-99m-tetrofosmin scintigraphic evaluation before PCI. RSSI on thallium-glucose-insulin SPECT was significantly greater (0.7±0.5 vs 1.5±0.4, p<0.01) and regional wall motion score was significantly less (1.46±0.50 vs 2.08±0.78, p<0

  11. Pulse wave as an alternate signal for data synchronization during gated myocardial perfusion SPECT imaging.

    Science.gov (United States)

    Lang, Otto; Trojanova, Helena; Balon, Helena R; Kunikova, Ivana; Bilwachs, Milos; Penicka, Martin; Kaminek, Milan; Myslivecek, Miroslav

    2011-09-01

    Proper identification of the cardiac cycle is essential for gated SPECT myocardial perfusion imaging. We have developed an alternate method of ECG for gating, that is, using the peripheral pulse wave (PW) as the triggering signal for gated SPECT acquisition. The aim of this study is to compare the use of this method of gating with the standard ECG trigger. We tested the PW triggering by comparing it with the ECG trigger. We evaluated 33 patients (25 males, 8 females), average age of 61 years (39-80) referred for stress myocardial perfusion imaging. Data from all patients were acquired twice and were processed by CEqual and QGS software. We compared the left ventricular ejection fraction (LVEF), end-diastolic and end-systolic volumes (EDV, ESV). Paired t test and Pearson correlation coefficient were used for comparison. The mean LVEF, EDV, and ESV calculated with the ECG trigger were 0.52, 120, and 64, respectively, those with the pulse-wave trigger were 0.48, 126, and 71, respectively. Mean paired difference for LVEF was -0.034 (P<0.001), for EDV 5.9 (P=0.012), and for ESV 7.9 (P<0.001). Pearson correlation coefficient for LVEF was 0.955, for EDV 0.987, and for ESV 0.991 (P<0.001 for all correlations). Triggering of gated-data acquisition by the PW is feasible. Quantitative parameters of cardiac function correlate highly with those obtained from the ECG trigger and the absolute differences are not clinically significant across a wide range of values.

  12. Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Nagaki, Akio; Sasaki, Masayuki

    2014-01-01

    IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ-SPECT in patients with coronary artery disease (CAD). Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ( 99m Tc-tetrofosmin, 9.6 min and 201 Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for 99m Tc-tetrofosmin and 6.2 min for 201 Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in 99m Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the 201 Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for 99m Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for 201 Tl), quantitative parameters were not significantly different between

  13. The clinical value and limitation of exercise electrocardiography and exercise thallium-201 myocardial scintigraphy in the diagnosis of coronary artery disease, with special reference to single vessel disease

    International Nuclear Information System (INIS)

    Fujioka, Tatsuo; Shibata, Nitaro; Shimizu, Yoichi; Itoh, Yukiyoshi; Abe, Mitsuki; Tanaka, Toshihide; Matsuda, Mitsukazu; Obunai, Yoshio

    1984-01-01

    The clinical value and limitation of exercise electrocardiography and exercise thallium-201 myocardial scintigraphy were studied in 40 patients with no previous history of myocardial infarction. Coronary angiography was performed on all the patients. Compared with thallium-201 myocardial scintigraphy, treadmill exercise electrocardiography showed greater sensitivity (84% versus 63%) in diagnosing coronary stenosis of more than 50%. In patients with single vessel discase, the results of sensitivities were similar (75% to 65%). However, the specificity of thallium-201 myocardial scintigraphy was higher than that of exercise electrocardiography (100% compared to 63%). Nine patients with evidence of significant lesions using coronary angiography, showed normal conditions using exercise electrocardiography and thallium myocardial scintigraphy examinations as well. All these patients had a history of chest pain, and 4 of them experienced chest pain during exercise. In cases with false negative exercise tests, the clinical symptoms and exercise-induced chest pain seem to be important diagnostic signs when evaluating patients with coronary artery disease. In 15 patients with isolated single vessel coronary artery disease (more than 75% stenosis of luminal diameter in only one vessel), the site of ST segment depression did not coincide with the stenotic lesion. The site of reversible perfusion defect on thallium-201 myocardial scintigraphy did, however, coincide with the site of myocardial ishemia and the stenotic lesion in most cases. (author)

  14. assessment of the clinical role of simultaneous 99mTc-MIBI and 201Tl dual-isotopic myocardial perfusion SPECT imaging in the patients wit hypertension

    International Nuclear Information System (INIS)

    Xie Wenhui; Zhang Lihua; Hu Shilong; Yang Shunfang; Zeng Jun

    2004-01-01

    Objective: To study the clinical role of Simultaneous rest technetium-99m sestamibi ( 99m Tc-MIBI) and stress thallium-201 (201Tl) Dual-isotopic myocardial perfusion SPECT imaging in the patients with hypertension. Methods: 116 patients with high blood pressure underwent simultaneous dual-isotopic myocardial perfusion SPECT imaging with 99m Tc-MIBI and 201Tl. 99m Tc-MIBI was injected at rest, 15 min later dobutamine was instilled into vein begin with 5 mg/kg/min, before and after instilling the base ECG, blood pressure, heart rate was recorded. when the maximal dose of Dobutamine was achieved, thallium-201 was injected, the dual-isotopic simultaneously SPECT imagine was performed. The stress and rest imagine was obtained. After tomographic reconstruction, the images were interpreted by two experienced observers without previous knowledge of results of other studies. Coronary angiography was performed in two weeks. All of 116 patients were found normal. Results: (1) All of 116 patients with high blood pressure were divided as three group by the course of disease: A group ( 20 year), 15. The heart/lung ratios of A, B, C group were 2.651±0.246, 2.546±0.231, 2.490±0.36 (mean±SD)respectively, no significant difference was noted among three group. Normal heart/lung ratios is 2.50±0.28 among of control group of 20. (2) The overall sensitivity for the dual-isotopic simultaneously myocardial SPECT imagine of high blood pressure was 46.55%(54/116). (3) Anterior, lateral, inferior, apex, interventricular septal segment were regarded as a whole segment, 111 segments display abnormal 201Tl uptake. 63, 30, 18 segments were in A, B, C group respectively, and no significant difference was noted among three group. 4 85 segments reveal reduced stressing 201Tl uptake and no typical redistribution was observed in the delay 201Tl imagines. 20, 24, 14, 12, 15 segments were in anterior, lateral, inferior, apex, interventricular septal segment respectively. 26 segments display

  15. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang; Feng, Jianlin; Lloyd, Michael S.; Chen, Ji

    2012-01-01

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  16. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang [First Affiliated Hospital of Nanjing Medical University, Department of Cardiology, Nanjing, Jiangsu (China); Feng, Jianlin [First Affiliated Hospital of Nanjing Medical University, Department of Nuclear Medicine, Nanjing, Jiangsu (China); Lloyd, Michael S. [Emory University School of Medicine, Division of Cardiology, Atlanta, GA (United States); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-07-15

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  17. Detection and assessment of unstable angina using myocardial perfusion imaging: Comparison between technetium-99m sestamibi SPECT and 12-lead electrocardiogram

    International Nuclear Information System (INIS)

    Gregoire, J.; Theroux, P.

    1990-01-01

    Forty-five studies using technetium-99m (Tc-99m) sestamibi single photon emission computed tomography (SPECT) were performed on patients hospitalized for spontaneous chest pain suggestive of myocardial ischemia. The studies were done after an injection during an episode of chest pain and a repeated injection when the patients were free of pain. All patients were hospitalized with a presumed diagnosis of unstable angina, and none had evidence of a previous myocardial infarction. The presence of a perfusion defect observed with Tc-99m sestamibi injected during chest pain had a 96% sensitivity and a 79% specificity for the detection of significant coronary artery disease (stenosis greater than or equal to 50%) on subsequent angiography. When the criterion of a larger perfusion defect during pain compared to absence of pain was used, the sensitivity was 81% and the specificity was 84%. In contrast, transient electrocardiographic ischemic changes during pain had a sensitivity of 35% and a specificity of 68%; electrocardiographic changes during or outside episodes of chest pain had a sensitivity of 65% and a specificity of 63% for the diagnosis. Tc-99m sestamibi SPECT represents a reliable noninvasive diagnostic tool that could aid in the diagnosis of myocardial ischemia in patients with spontaneous chest pain and provide additional information to that provided by the electrocardiogram

  18. SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: A meta analysis

    International Nuclear Information System (INIS)

    Zhou, Tao; Yang, Lin-feng; Zhai, Ji-liang; Li, Jiang; Wang, Qi-meng; Zhang, Rui-jie; Wang, Sen; Peng, Zhao-hui; Li, Min; Sun, Gang

    2014-01-01

    Purpose: The present meta-analysis illustrates the accuracy of myocardial perfusion SPECT (MPS) to diagnose functional stenotic coronary artery disease (CAD) with fractional flow reserve (FFR) as standard reference. Methods: All investigators screened and selected studies that compared MPS with FFR in symptomatic patients with suspected CAD. Patients and study characteristics were independently extracted by two investigators; differences were resolved by consensus. Results: 13 articles, including 1,017 patients, 699 vessels were included in the study. No significant publication bias was detected (P = 0.65). At the patient level, the summary sensitivity and specificity were 77% (95% confidence interval [CI], 70–83%) and 77% (95%CI, 67–84%) for MPS. Vessel-level pooled sensitivity was 66% (95%CI, 57–74%) and specificity was 81% (95%CI, 70–89%). The overall diagnostic performance of MPS was moderate. [The area under the summary receiver operating characteristic (sROC) curve was 0.83]. No study influenced the pooled results larger than 0.03. Conclusions: The accuracy between FFR and MPS SPECT was moderate

  19. SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: A meta analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tao; Yang, Lin-feng [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Zhai, Ji-liang [Department of Medical Imaging, The Branch of TaiAn Central Hospital, Middle of Changcheng Road, Shandong Province, China. 271000 (China); Li, Jiang [Department of Medical Imaging, Affiliated Hospital of Taishan Medical University, No, 706, Taishan Road, Shandong Province, China. 271000 (China); Wang, Qi-meng [Department of Medical Imaging, Taishan Hospital of Traditional Chinese Medicine, No, 216, Yingxuan Street, Shandong Province, China. 271000. (China); Zhang, Rui-jie; Wang, Sen; Peng, Zhao-hui [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Li, Min, E-mail: liminyingxiang@163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China)

    2014-06-15

    Purpose: The present meta-analysis illustrates the accuracy of myocardial perfusion SPECT (MPS) to diagnose functional stenotic coronary artery disease (CAD) with fractional flow reserve (FFR) as standard reference. Methods: All investigators screened and selected studies that compared MPS with FFR in symptomatic patients with suspected CAD. Patients and study characteristics were independently extracted by two investigators; differences were resolved by consensus. Results: 13 articles, including 1,017 patients, 699 vessels were included in the study. No significant publication bias was detected (P = 0.65). At the patient level, the summary sensitivity and specificity were 77% (95% confidence interval [CI], 70–83%) and 77% (95%CI, 67–84%) for MPS. Vessel-level pooled sensitivity was 66% (95%CI, 57–74%) and specificity was 81% (95%CI, 70–89%). The overall diagnostic performance of MPS was moderate. [The area under the summary receiver operating characteristic (sROC) curve was 0.83]. No study influenced the pooled results larger than 0.03. Conclusions: The accuracy between FFR and MPS SPECT was moderate.

  20. Thoracic and abdominal SPECT imaging in systemic amyloidosis in identifying multiorgan involvement

    International Nuclear Information System (INIS)

    Wellman, H.N.; Benson, M.D.; Park, H.M.; Siddiqui, A.R.; Krepshaw, J.D.

    1988-01-01

    Thirty-three patients with systemic amyloidosis have been studied. Thoracic single photon emission computed tomography (SPECT) for myocardial involvement and skeletal imaging were performed with Tc-99m PYP, and abdominal SPECT with TcS colloid. Myocardial wall involvement was easily discernible with SPECT in 17 cases, and in many with normal ultrasonography. PYP uptake was also observed in liver (five patients), kidneys (four patients), and soft tissues (two patients). Most patients had widespread degenerative joint disease. With TcS colloid, intrinsic liver abnormalities were found in four patients, hepatomegaly in seven, and splenic infiltration in two. Nuclear SPECT and planar imaging characterize the distribution of systemic amyloidosis in organs, distribution not readily identified with other diagnostic modalities

  1. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  2. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    International Nuclear Information System (INIS)

    Weininger, Markus; Schoepf, U. Joseph; Ramachandra, Ashok; Fink, Christian; Rowe, Garrett W.; Costello, Philip; Henzler, Thomas

    2012-01-01

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  3. Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator

    International Nuclear Information System (INIS)

    Du, Yong; Frey, Eric C; Bhattacharya, Manojeet

    2014-01-01

    Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter

  4. Evaluating the effect of PTCA by exercise stress myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Lin Jinghui

    1992-01-01

    In this study, 44 patients after successful percutaneous transluminal coronary angioplasty (PTCA) were followed up by exercise stress myocardial perfusion imaging. In 28 patients with myocardial ischemia after PTCA, myocardial imaging of 75.0% patients reverted to normal or approximately normal. In 16 patients of myocardial infarction with ischemia after PTCA, myocardial imaging of only 37.5% patients reverted to normal or approximately normal, significantly less than myocardial ischemia. But the general efficacious incidence was similar in both groups. Most of 77 myocardial segments with complete or obvious redistribution returned to normal imaging after PTCA. During the follow-up coronary artery restenosis occurred in 6 cases, 5 of which were confirmed by coronary arteriography. Restenosis may be discovered as soon as possible, if a patient was reexamined by myocardial imaging 2-6 months after PTCA. The results of this study indicated that myocardial imaging is a noninvasive and reliable method for the assessment of PTCA therapeutic effect and follow up studies

  5. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  6. The prevalence and the clinical characteristics of silent myocardial ischemia detected by stress thallium scintigraphy

    International Nuclear Information System (INIS)

    Matsuo, Hitoshi; Watanabe, Sachiro; Nishida, Yoshio

    1992-01-01

    The prevalence of silent myocardial ischemia was retrospectively assessed in a group of 100 consecutive patients with angiographically proved coronary artery disease, and diagnostic ECG, by symptom-limited exercise thallium-201 scintigraphy. Twenty-four patients had no evidence of ischemia despite adequate exercise level. So among 76 patients with exercise induced ischemia, only 33 patients (43%) stopped exercise due to anginal pain (symptomatic ischemia: Group 3). And 43 patients with asymptomatic ischemia composed of 23 patients (30%) with ECG change (Group 2B) and 20 patients (26%) without ECG change (Group 2A). Patients background including the history of old myocardial infarction and diabetes mellitus, were similar among Group 2A, 2B, and Group 3. Our Major observation was that the extent and severity of quantified SPECT perfusion defects was nearly identified between 3 groups. Thus in this study group, there was a rather high prevalence rate of silent ischemia (57%) by exercise thallium-201 criteria. Patients with silent ischemia, associated with positive and negative exercise ECG findings, and those with exercise angina had similar background and comparable amount of jeopardized myocardium. (author)

  7. Impact of endothelial dysfunction on left ventricular remodeling after successful primary coronary angioplasty for acute myocardial infarction. Analysis by quantitative ECG-gated SPECT

    International Nuclear Information System (INIS)

    Matsuo, Shinro; Nakae, Ichiro; Matsumoto, Tetsuya; Horie, Minoru

    2006-01-01

    We hypothesized that endothelial cell integrity in the risk area would influence left ventricular remodeling after acute myocardial infarction. Twenty patients (61±8 y.o.) with acute myocardial infarction underwent 99m Tc-tetrofosmin imaging in the sub-acute phase and three months after successful primary angioplasty due to myocardial infarction. All patients were administered angiotensin-converting enzyme inhibitor after revascularization. Cardiac scintigraphies with quantitative gated SPECT were performed at the sub-acute stage and again 3 months after revascularization to evaluate left ventricular (LV) remodeling. The left ventricular ejection fraction (EF) and end-systolic and end-diastolic volume (ESV, EDV) were determined using a quantitative gated SPECT (QGS) program. Three months after myocardial infarction, all patients underwent cardiac catheterization examination with coronary endothelial function testing. Bradykinin (BK) (0.2, 0.6, 2.0 μg/min) was administered via the left coronary artery in a stepwise manner. Coronary blood flow was evaluated by Doppler flow velocity measurement. Patients were divided into two groups by BK-response: a preserved endothelial function group (n=10) and endothelial dysfunction group (n=10). At baseline, both global function and LV systolic and diastolic volumes were similar in both groups. However, LV ejection fraction was significantly improved in the preserved-endothelial function group, compared with that in the endothelial dysfunction group (42±10% to 48±9%, versus 41±4% to 42±13%, p<0.05). LV volumes progressively increased in the endothelial dysfunction group compared to the preserved-endothelial function group (123±45 ml to 128±43 ml, versus 111±47 ml to 109±49 ml, p<0.05). In re-perfused acute myocardial infarction, endothelial function within the risk area plays an important role with left ventricular remodeling after myocardial infarction. (author)

  8. Myocardial Ischaemia, Coronary Atherosclerosis and Pulmonary Pressure Elevation in Antiphospholipid Syndrome Patients.

    Science.gov (United States)

    Padjas, Agnieszka; Płazak, Wojciech; Celińska-Lowenhoff, Magdalena; Mazurek, Adam; Perricone, Carlo; Podolec, Piotr; Musiał, Jacek

    2016-01-01

    Thrombotic events in antiphospholipid syndrome (APS) involve venous and arterial circulation with the possible involvement of coronary or pulmonary microcirculation. To evaluate the influence of antiphospholipid antibodies (aPL) and on myocardial ischaemia assessed by single-photon emission computerized tomography (SPECT), coronary atherosclerosis assessed by multidetector computerized tomography (MDCT) and pulmonary pressure assessed by transthoracic echocardiography (TTE) in patients with primary antiphospholipid syndrome (PAPS). TTE, SPECT (Tc 99m sestamibi) and MDCT-based coronary calcium scoring were performed in 26 consecutive PAPS patients (20 females, 6 males, aged 20-61, mean 39.7) without any signs of other autoimmunological disease and without clinical symptoms of heart disease. Out of 26 patients, TEE showed normal left and right ventricle function in 25 (96.2%) and elevated (≥ 30 mm Hg) right ventricle systolic pressure in 7 (26.9%) patients. SPECT revealed myocardial perfusion defects in 15 (57.7%) patients: exercise-induced in 6 (23.1%) and persistent in 11 (42.3%). MDCT revealed coronary calcifications in 4 (15.4%) patients. The number of plaques ranged from 1 to 11 (median 2), volume 3-201.7 mm³ (median 7), calcium scores 1.3-202.6 (median 5.7). In the group with perfusion defects or coronary calcifications (n = 15), all the patients showed elevated aCL IgG. In most of the relatively young APS patients, without any symptoms of ischemic heart disease, SPECT showed myocardial perfusion defects, and coronary calcifications in 1/6 of them. Right ventricle systolic pressure was elevated in 1/4 of APS patients. These pathologies, well known as cardiovascular risk markers, were associated with elevated levels of the IgG class of both anti-cardiolipin and antiB2 GPI antibodies. Thus, in a high percentage of APS patients, clinically silent myocardial ischaemia, pulmonary pressure elevation and coronary atherosclerosis are present and related to the

  9. Diagnostic value of R wave amplitude changes during exercise testing after myocardial infarction

    NARCIS (Netherlands)

    de Hert, S.; Vrints, C.; Vanagt, E.; Snoeck, J.

    1986-01-01

    To determine the diagnostic value of R wave amplitude changes occurring during exercise testing after myocardial infarction, exercise ECG's and coronary angiograms were reviewed in 76 postinfarction patients and in 40 patients with normal coronary arteries. During exercise, an increase in R wave

  10. Changes in myocardial perfusion due to physical exercise in patients with stable coronary artery disease

    International Nuclear Information System (INIS)

    Kendziorra, Kai; Foerster, Marcus; Sabri, Osama; Kluge, Regine; Walther, Claudia; Moebius-Winkler, Sven; Conradi, Katrin; Schuler, Gerhard; Hambrecht, Rainer

    2005-01-01

    Percutaneous transluminal coronary angioplasty (PTCA) is one of the main therapy options for patients with coronary artery disease (CAD), resulting in an improvement in myocardial perfusion and exercise capacity. Nevertheless, studies have also demonstrated a positive effect of regular exercise training on myocardial perfusion and maximum exercise capacity. The aim of this study was to evaluate changes in myocardial stress perfusion after 1 year of exercise training in comparison with the effects of PTCA in patients with CAD. In 66 male patients with angiographically confirmed significant coronary artery stenosis in one target vessel, myocardial perfusion scintigraphy was performed at baseline and 12 months after randomisation into either a physical exercise group or a PTCA group. Circumferential count rate profiles in 16 wall segments were classified according to their relative count rate and localisation within or outside the area supplied by the stenosed vessel. Ischaemic segments showed a significant improvement in myocardial count rate within the target area after 12 months in both the PTCA and the training group (PTCA group: from 76.8±4.9% to 86.6±10.9%, p=0.03; training group: from 74.0±7.3% to 83.7±10.8%, p<0.01). Outside the target area only the training group showed a significant improvement (from 77.7±4.4% to 91.7±4.8%, p<0.01). Our data indicate a significant improvement in stress myocardial perfusion in the training group after 12 months. The ischaemia is reduced not only in the target region of the leading stenosis but also in other ischaemic myocardial areas. In contrast, after PTCA stress perfusion improves only in the initially ischaemic parts of the target area. (orig.)

  11. Microvascular obstruction on delayed enhancement cardiac magnetic resonance imaging after acute myocardial infarction, compared with myocardial {sup 201}Tl and {sup 123}I-BMIPP dual SPECT findings

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Hiroaki [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Department of Cardiology, Kainan Hospital, Yatomi (Japan); Isobe, Satoshi, E-mail: sisobe@med.nagoya-u.ac.jp [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Sakai, Shinichi [Department of Cardiology, Kainan Hospital, Yatomi (Japan); Yamada, Takashi [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Watanabe, Naoki; Miura, Manabu [Department of Cardiology, Kainan Hospital, Yatomi (Japan); Uchida, Yasuhiro; Kanashiro, Masaaki; Ichimiya, Satoshi [Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi (Japan); Okumura, Takahiro; Murohara, Toyoaki [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2015-08-15

    Highlights: • The percentage infarct size (%IS) was significantly greater in the microvascular obstruction (MO) group than in the non-MO group. • The percentage mismatch score (%MMS) on dual scintigraphy significantly correlated with the %IS and the percentage MO. • The %MMS was significantly greater in the non-MO group than in the MO group, and was an independent predictor for MO. - Abstract: Background: The hypo-enhanced regions within the hyper-enhanced infarct areas detected by cardiac magnetic resonance (CMR) imaging reflect microvascular obstruction (MO) after acute myocardial infarction (AMI). The combined myocardial thallium-201 ({sup 201}Tl)/iodine-123-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid ({sup 123}I-BMIPP) dual single-photon emission computed tomography (SPECT) is a useful tool for detecting myocardial reversibility after AMI. We evaluated whether MO could be an early predictor of irreversible myocardial damage in comparison with {sup 201}Tl and {sup 123}I-BMIPP dual SPECT findings in AMI patients. Methods: Sixty-two patients with initial AMI who successfully underwent coronary revascularization were enrolled. MO was defined by CMR imaging. Patients were divided into 2 groups as follows: MO group (n = 32) and non-MO group (n = 30). Scintigraphic defect scores were calculated using a 17-segment model with a 5-point scoring system. The mismatch score (MMS) was calculated as follows: the total sum of (Σ) {sup 123}I-BMIPP defect score minus Σ{sup 201}Tl defect score. The percentage mismatch score (%MMS) was calculated as follows: MMS/(Σ{sup 123}I-BMIPP score) × 100 (%). Results: The percentage infarct size (%IS) was significantly greater in the MO group than in the non-MO group (32.2 ± 13.8% vs. 18.3 ± 12.1%, p < 0.001). The %MMS significantly correlated with the %IS and the percentage MO (r = −0.26, p = 0.03; r = −0.45, p < 0.001, respectively). The %MMS was significantly greater in the non-MO group than in the MO group (45.4

  12. Simultaneous assessment of myocardial perfusion and function during mental stress in patients with chronic coronary artery disease.

    Science.gov (United States)

    Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert

    2003-01-01

    Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS

  13. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  14. New application of myocardial infarct map using a dual isotope single photon emission computed tomography (SPECT) of [99mTc]pyrophosphate and [201Tl]chloride in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Hiroe, Michiaki; Muramatsu, Yasuji; Sugimoto, Keiichi; Tsujino, Motoyoshi; Maejima, Michihiro; Miyahara, Yasuhiro; Taniguchi, Koichi; Matsui, Susumu; Mizukawa, Katsumi.

    1988-01-01

    In 12 patients with acute myocardial infarction, a dual isotope SPECT was applied to describe a myocardial infarct map for detecting the site and the extent of the infarct. Threshold cut-off level was determined as 55 % for [ 99m Tc] and 35 % for [ 201 Tl] according to cardiac phantom studies. Multiple cardiac tomograms showed two different uptakes of the isotopes in indentical slices and regions. Then, color tomograms were described on the red and green image for [ 99m Tc] and for [ 201 Tl], respectively, and Bulls eye map was drawn in the two colored fashion as the myocardial infarct map. In all patients, the infarct map was successful to determine the exact site of the infarct and the overlapped area by the viable myocardium. In conclusion, this functional map of acute myocardial infarction may be useful for understanding three dimensional area of the infarct and the viable myocardium easily and exactly. (author)

  15. Quantification of the myocardial area at risk using coronary CT angiography and Voronoi algorithm-based myocardial segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Akira; Kono, Atsushi; Coenen, Adriaan; Saru-Chelu, Raluca G.; Krestin, Gabriel P. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Sakamoto, Tsuyoshi [AZE inc, Development Division, Chiyoda, Tokyo (Japan); Kido, Teruhito; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Higashino, Hiroshi [Yotsuba Circulation Clinic, Department of Radiology, Matsuyama, Ehime (Japan); Abe, Mitsunori [Yotsuba Circulation Clinic, Department of Cardiology, Matsuyama, Ehime (Japan); Feyter, Pim J. de; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2015-01-15

    The purpose of this study was to estimate the myocardial area at risk (MAAR) using coronary computed tomography angiography (CTA) and Voronoi algorithm-based myocardial segmentation in comparison with single-photon emission computed tomography (SPECT). Thirty-four patients with coronary artery disease underwent 128-slice coronary CTA, stress/rest thallium-201 SPECT, and coronary angiography (CAG). CTA-based MAAR was defined as the sum of all CAG stenosis (>50 %) related territories (the ratio of the left ventricular volume). Using automated quantification software (17-segment model, 5-point scale), SPECT-based MAAR was defined as the number of segments with a score above zero as compared to the total 17 segments by summed stress score (SSS), difference (SDS) score map, and comprehensive SPECT interpretation with either SSS or SDS best correlating CAG findings (SSS/SDS). Results were compared using Pearson's correlation coefficient. Forty-nine stenoses were observed in 102 major coronary territories. Mean value of CTA-based MAAR was 28.3 ± 14.0 %. SSS-based, SDS-based, and SSS/SDS-based MAAR was 30.1 ± 6.1 %, 20.1 ± 15.8 %, and 26.8 ± 15.7 %, respectively. CTA-based MAAR was significantly related to SPECT-based MAAR (r = 0.531 for SSS; r = 0.494 for SDS; r = 0.814 for SSS/SDS; P < 0.05 in each). CTA-based Voronoi algorithm myocardial segmentation reliably quantifies SPECT-based MAAR. (orig.)

  16. Quantification of the myocardial area at risk using coronary CT angiography and Voronoi algorithm-based myocardial segmentation

    International Nuclear Information System (INIS)

    Kurata, Akira; Kono, Atsushi; Coenen, Adriaan; Saru-Chelu, Raluca G.; Krestin, Gabriel P.; Sakamoto, Tsuyoshi; Kido, Teruhito; Mochizuki, Teruhito; Higashino, Hiroshi; Abe, Mitsunori; Feyter, Pim J. de; Nieman, Koen

    2015-01-01

    The purpose of this study was to estimate the myocardial area at risk (MAAR) using coronary computed tomography angiography (CTA) and Voronoi algorithm-based myocardial segmentation in comparison with single-photon emission computed tomography (SPECT). Thirty-four patients with coronary artery disease underwent 128-slice coronary CTA, stress/rest thallium-201 SPECT, and coronary angiography (CAG). CTA-based MAAR was defined as the sum of all CAG stenosis (>50 %) related territories (the ratio of the left ventricular volume). Using automated quantification software (17-segment model, 5-point scale), SPECT-based MAAR was defined as the number of segments with a score above zero as compared to the total 17 segments by summed stress score (SSS), difference (SDS) score map, and comprehensive SPECT interpretation with either SSS or SDS best correlating CAG findings (SSS/SDS). Results were compared using Pearson's correlation coefficient. Forty-nine stenoses were observed in 102 major coronary territories. Mean value of CTA-based MAAR was 28.3 ± 14.0 %. SSS-based, SDS-based, and SSS/SDS-based MAAR was 30.1 ± 6.1 %, 20.1 ± 15.8 %, and 26.8 ± 15.7 %, respectively. CTA-based MAAR was significantly related to SPECT-based MAAR (r = 0.531 for SSS; r = 0.494 for SDS; r = 0.814 for SSS/SDS; P < 0.05 in each). CTA-based Voronoi algorithm myocardial segmentation reliably quantifies SPECT-based MAAR. (orig.)

  17. Comparison of Nitrate-augmented resting gated 99mTc-Sestamibi imaging with Low Dose Dobutamine SPECT for the detection of Myocardial Viability

    International Nuclear Information System (INIS)

    Parameswaran, R.V.; Dash, P.K.; Barooah, B.; Guruprasad, H.P.; Purantharan, N.

    2002-01-01

    Background: Dobutamine Echocardiography and Radionuclide imaging with Tl-201 and Technetium agents are two of the most established techniques available for the detection of viable myocardium. The purpose of this study was to evaluate the utility of Low dose Dobutamine gated Myocardial SPECT in identifying additional areas of dysfunctional, but viable myocardium when compared to nitrate-augmented rest gated SPECT with SestaMIBI. Materials and Methods: 20 patients (19 males and 1 female, with an age range of 40- 65 yrs and a mean of 52.75yrs) all with history of MI or severe LV dysfunction were included in this study. Patients with LBBB, recent revascularisation, arrhythmias etc were excluded from the study. A routine stress-rest study was initially performed on them with 99mTc-SestaMIBI and both the stress as well as resting studies was gated and the resting study was augmented with 10mg of sublingual nitrate. After the resting study was over, the patient was infused with Low dose Dobutamine(5μg/kg/min), at which time the gated acquisition was started and the infusion was continued till the acquisition got completed. In the perfusion study with SestaMIBI, all infarct segments which have uptake less than 50% as compared to the maximally perfused area was deemed non-viable Results: A 17-segment Myocardial model was used for both perfusion as well as quantification of wall motion and wall thickening. 110 akinetic/dyskinetic segments were taken up for analysis. 93 of these segments were non-viable and improvement in wall motion was seen in 17 segments (15.4%) in the nitrate-augmented SPECT. Dobutamine study showed improvement in totally in 27 segments (24.5%), 10 of which were additional segments which were non-viable in Nitrate SPECT study, apart from the 17 segments which showed improvement in the Nitrate study. In Dobutamine study, there was also improvement in wall thickening in 10 (10.7%) out of 93 segments which had showed less than 50% of MIBI uptake. Conclusion

  18. Noninvasive assessment of changes in myocardial perfusion and ventricular performance following exercise training

    International Nuclear Information System (INIS)

    Tubau, J.; Witztum, K.; Froelicher, V.; Jensen, D.; Atwood, E.; McKirnan, M.D.; Reynolds, J.; Ashburn, W.

    1982-01-01

    Seventeen coronary patients (CAD) underwent 201 Tl treadmill and radionuclide (RNV) ejection fraction supine bicycle testing before and after 5.6 +/- 1.6 (mean +/- SD) months of an exercise program. Thallium data were assessed both using analog images and a computerized circumferential profile technique. Patients exercised on the treadmill to a higher workload after the exercise program, but achieved a similar pressure-rate product. When interpreting the analog thallium images, only 50% agreement was obtained for the assessment of changes in myocardial perfusion (pre/post-training). The computer technique, however, had low inter-intraobserver variability (6%) and better agreement (90.5%). Using the circumferential profile method, five patients improved (a total of 11 regions) and one patient worsened (with two regions). Before the exercise program, the ejection fraction (EF) response to supine bike exercise was normal (an increase greater than 11%) in four, flat in seven, and severely abnormal (a decrease of more than 4%) in six patients. After the exercise program, even though achieving similar or higher pressure-rate products, six patients improved their EF response, nine did not change, and two worsened. Of the five patients who improved their thallium images, one improved his EF response, two remained normal, and two did not change. One patient worsened both his thallium study and the EF response after the exercise program. Changes in thallium exercise images and the EF response to supine exercise occurred in our patients after an exercise program, but were not always concordant. Indeed, of five patients with exercise-induced ischemic ST changes before and after training, the EF response improved in three whereas myocardial perfusion was unchanged. Reasons for this lack of agreement are discussed, and have been considered in the planning of a randomized trial of the effects of an exercise program on myocardial perfusion and function

  19. Thallium-201 exercise myocardial imaging to evaluate myocardial perfusion after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Hirzel, H.O.; Nuesch, K.; Sialer, G.; Horst, W.; Krayenbuehl, H.P.

    1980-01-01

    To assess the usefulness of thallium-201 exercise scintigraphy in evaluating myocardial perfusion after coronary artery bypass surgery, imaging was performed after submaximal bicycle ergometry and at rest in 54 patients before and within 24 +- 10 (SD) weeks after operation. Scintigraphy identified 8 out of 20 patients who were symptom free after operation and showed normal exercise electrocardiograms as still having exercise-induced ischaemia and thus as having not truly benefited from the surgical intervention. In contrast, improvement in perfusion was documented in 17 out of 31 patients despite further complaints of chest pain and persistence of a pathological exercise electrocardiogram in 6 of them. Bypass graft patency rate paralleled the scintigraphic findings in the 35 patients who were restudied arteriographically. It was concluded that thallium-201 exercise scintigraphy is a useful technique to document changes in regional perfusion after surgery and is definitely superior to the clinical evaluation of patients including the exercise electrocardiogram. (author)

  20. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  1. Comparison of myocardial Perfusion imaging by thallium-201 single-photon emission computed tomography with SUNY4001 (adenosine) and exercise. Crossover clinical trial at multi-center

    International Nuclear Information System (INIS)

    Nishimura, Shigeyuki; Nishimura, Tsunehiko; Yamazaki, Junichi

    2004-01-01

    We compared the ischemic diagnosis ability and adverse events of 201 Tl myocardial perfusion imaging with SUNY4001 (adenosine) stress to that with exercise (ergometer) stress both on random crossover trial. Thirty one known or suspected chronic stable angina patients who are able to exercise and 10 healthy volunteers were enrolled for the trial. The early and delayed images were obtained by SPECT imaging. The concordance of diagnoses [ischemia vs. no ischemia] between the two types of stresses was 97.3% (36/37) [Kappa: 0.9068]. The sensitivity and specificity based on the exercise test were 100% (6/6) and 96.8% (30/31) respectively. The incidence of adverse events caused by SUNY4001 and the exercise were 44.7% (17/38) and 52.6% (20/38), respectively. Major adverse events caused by SUNY4001 were blood pressure (BP) decrease, flushing and headache. And those by exercise were ST decrease, dyspnea and chest pain. None of the adverse events required the intervention or caused life-threatening complication in the trial. The trial showed that the ischemic diagnosis ability and safety of 201 Tl scintigraphy with SUNY4001 stress are almost equal to those of the exercise stress that is considered as the standard stress method. We concluded that 201 Tl imaging with SUNY4001 is safe and useful for detecting ischemic heart disease, especially for patients unable to exercise adequately. (author)

  2. Gated single photon emission computer tomography for the detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Pena Q, Yamile; Coca P, Marco Antonio; Batista C, Juan Felipe; Fernandez-Britto, Jose; Quesada P, Rodobaldo; Pena C; Andria

    2009-01-01

    Background: Asymptomatic patients with severe coronary atherosclerosis may have a normal resting electrocardiogram and stress test. Aim: To assess the yield of Gated Single Photon Emission Computer Tomography (SPECT) for the screening of silent myocardial ischemia in type 2 diabetic patients. Material and methods: Electrocardiogram, stress test and gated-SPECT were performed on 102 type 2 diabetic patients aged 60 ± 8 years without cardiovascular symptoms. All subjects were also subjected to a coronary angiography, whose results were used as gold standard. Results: Gated-SPECT showed myocardial ischemia on 26.5% of studied patients. The sensibility, specificity, accuracy, positive predictive value and negative predictive value were 92.3%, 96%, 95%, 88.8%, 97.3%, respectively. In four and six patients ischemia was detected on resting electrocardiogram and stress test, respectively. Eighty percent of patients with doubtful resting electrocardiogram results and 70% with a doubtful stress test had a silent myocardial ischemia detected by gated-SPECT. There was a good agreement between the results of gated-SPECT and coronary angiography (k =0.873). Conclusions: Gated-SPECT was an useful tool for the screening of silent myocardial ischemia

  3. Chocolate intake may reduce liver count in 99m-Tc-tetrofosmin myocardial SPECT

    International Nuclear Information System (INIS)

    Tsunekawa, Akikazu; Yasuda, Eisuke; Okuda, Seiji

    2005-01-01

    The accumulation of 99m-Tc-Tetrofosmin (TF) in the liver and intestine may often interfere the image quality of myocardial TF SPECT. Although milk intake before acquisition is recommended to reduce its accumulation by enhancing biliary excretion of TF, some patients cannot accept milk. To elucidate the efficacy of chocolate intake as a substitute for milk, we investigated 72 patients with coronary heart disease who underwent TF SPECT (stress imaging; n=36, rest imaging; n=36). Following injection of TF, the patients were randomly treated either with milk (n=24), or chocolate (n=24). The images were acquired before treatment, at 15 min, at 30 min, and 45 min after treatment. The ratio of liver to heart count (LHR) was calculated and was compared between the two groups. LHR in the stress imaging was not significantly different between the milk-treated and chocolate-treated groups: 1.86 vs 1.87 before treatment, 1.39 vs 1.39 at 30 min, and 1.02 vs 1.03 at 45 min. LHR in the rest imaging was also the same between the two groups: 1.43 vs 1.42 before treatment, 1.22 vs 1.21 at 15 min, and 0.95 vs. 0.95 at 30 min. Chocolate intake may be equally effective to milk intake in reducing the liver accumulation of TF. (author)

  4. The Association between Left Verticle Diastolic Dysfunction and Endothelial Dysfunction and the Result of Stress Myocardial SPECT in Asymptomatic Patients with Type 2 Diabetes

    Czech Academy of Sciences Publication Activity Database

    Charvát, J.; Michalová, K.; Chlumský, J.; Valenta, Zdeněk; Kvapil, M.

    2005-01-01

    Roč. 33, - (2005), s. 473-482 ISSN 0300-0605 Institutional research plan: CEZ:AV0Z10300504 Keywords : coronary heart disease * type 2 diabetes mellitus * left ventricular diastolic dysfunction * left ventricular hyperthropy * stress myocardial SPECT Subject RIV: FA - Cardiovascular Disease s incl. Cardiotharic Surgery Impact factor: 0.653, year: 2005

  5. Myocardial perfusion SPECT 2015 in Germany. Results of the 7th survey.

    Science.gov (United States)

    Lindner, Oliver; Burchert, Wolfgang; Schäfer, Wolfgang; Hacker, Marcus

    2017-02-14

    The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine presents the results of the 7th survey of myocardial perfusion SPECT (MPS) of the reporting year 2015. 268 questionnaires (173 practices [PR], 67 hospitals [HO], 28 university hospitals [UH]) were evaluated. Results of the last survey from 2012 are set in squared brackets. MPS of 121 939 [105 941] patients were reported. 98 % [95 %] of all MPS were performed with Tc-99m radiopharmaceuticals and 2 % [5 %] with Tl-201. 78 % [79 %] of all patients were studied in PR, 14 % [15 %] in HO, and 8 % [6 %] in UH. A pharmacological stress test was performed in 43 % [39 %] (22 % [24 %] adenosine, 20 % [9 %] regadenoson, 1 % [6 %] dipyridamole or dobutamine). Attenuation correction was applied in 25 % [2009: 10 %] of MPS. Gated SPECT was performed in 78 % [70 %] of all rest MPS, in 80 % [73 %] of all stress and in 76 % [67 %] of all stress and rest MPS. 53 % [33 %] of all nuclear medicine departments performed MPS scoring by default, whereas 24 % [41 %] did not apply any quantification. 31 % [26 %] of all departments noticed an increase in their counted MPS and 29 % [29 %] no changes. Data from 89 departments which participated in all surveys showed an increase in MPS count of 11.1 % (PR: 12.2 %, HO: 4.8 %, UH: 18.4 %). 70 % [60 %] of the MPS were requested by ambulatory care cardiologists. The 2015 MPS survey reveals a high-grade adherence of routine MPS practice to current guidelines. The positive trend in MPS performance and number of MPS already observed in 2012 continues. Educational training remains necessary in the field of SPECT scoring.

  6. Methods of gated-blood-pool-spect data processing

    International Nuclear Information System (INIS)

    Kosa, I.; Mester, J.; Tanaka, M.; Csernay, L.; Mate, E.; Szasz, K.

    1991-01-01

    Three techniques of gated SPECT were evaluated. The methods of Integral SPECT (ISPECT), enddyastole-endsystole SPECT (ED-ES SPECT) and Fourier SPECT were adapted and developed on the Hungarian nuclear medicine data processing system microSEGAMS. The methods are based on data reduction before back projection which results in processing times acceptable for the clinical routine. The clinical performance of the introduced techniques was tested in 10 patients with old posterior myocardial infarction and in 5 patients without cardiac disease. The left ventricular ejection faction determined by ISPECT correlated well with the planar values. The correlation coefficient was 0.89. The correlation coefficient of EF values determined by ED-ES SPECT and planar radionuclide ventriculography was lower (0.70). For the identification of left ventricular wall motion abnormalities ED-ES SPECT and Fourier SPECT exhibited a favourable performance, but ISPECT only moderate suitability. In the detection of regional phase delay Fourier-SPECT demonstrated higher sensitivity than the planar radionuclide ventriculography. (author) 4 refs.; 3 figs.; 2 tabs

  7. Thallium-201 myocardial imaging in evaluation of asymptomatic individuals with ischaemic ST segment depression on exercise electrocardiogram

    International Nuclear Information System (INIS)

    Caralis, D.G.; Bailey, I.; Kennedy, H.L.; Pitt, B.

    1979-01-01

    This study showed that asymptomatic adults with normal physical examination, normal resting electrocardiogram, and normal routine laboratory evaluation who had a positive exercise electrocardiogram and abnormal exercise thallium-201 myocardial image had a very high probability of angiographically significant coronary artery disease. If, on the other hand, the exercise electrocardiogram was positive for 'ischaemic' ST segment changes, but the exercise thallium image was normal, the probability for coronary disease was low. The exercise electrocardiogram combined with thallium-201 myocardial image are safe non-invasive methods which can be performed on an out-patient basis. (author)

  8. Usefulness of percutaneous transluminal coronary angioplasty in silent myocardial ischemia

    International Nuclear Information System (INIS)

    Hou, Mami

    1996-01-01

    The usefulness of percutaneous transluminal coronary angioplasty (PTCA) was assessed in patients with exercise-induced asymptomatic myocardial ischemia (silent ischemia) and compared with exercise-induced symptomatic myocardial ischemia (symptomatic ischemia). Patients with single vessel coronary artery disease (51 with angina pectoris, 40 with old myocardial infarction) and evidence of stress-induced ischemia on thallium-201 single photon emission computed tomography (SPECT) underwent successful PTCA. Thirty-seven percent of angina patients and 60% of infarction patients showed asymptomatic exercise-induced ischemia. There was no significant difference in population characteristics between silent and symptomatic patients. Patients with silent angina had significantly higher percentage thallium uptake and washout rate than symptomatic patients. After PTCA, both percentage diameter stenosis and percentage thallium uptake were improved in all patients with angina irrespective of the presence or absence of symptoms. There were no significant differences in percentage thallium uptake and washout rate between patients with silent and symptomatic infarction. After PTCA, percentage diameter stenosis, percentage thallium uptake, and washout rate improved in all infarction patients irrespective of the symptoms. Zero percent of silent angina patients, 12% of symptomatic angina patients, 12% of silent infarction patients, 19% of symptomatic infarction patients had cardiac events during about 4.5 years after PTCA. The incidence of cardiac events did not significantly differ in any patient group. PTCA improved myocardial perfusion in all patients, and the incidence of cardiac events did not differ between the silent and symptomatic groups. Revascularization with PTCA is suitable for patients with silent as well as symptomatic ischemia. (author)

  9. Quantification of absolute myocardial perfusion at rest and during exercise with positron emission tomography after human cardiac transplantation

    International Nuclear Information System (INIS)

    Krivokapich, J.; Stevenson, L.W.; Kobashigawa, J.; Huang, S.C.; Schelbert, H.R.

    1991-01-01

    The maximal exercise capacity of cardiac transplant recipients is reduced compared with that of normal subjects. To determine if this reduced exercise capacity is related to inadequate myocardial perfusion during exercise, myocardial perfusion was measured noninvasively with use of positron emission tomography and nitrogen (N)-13 ammonia. Twelve transplant recipients with no angiographic evidence of accelerated coronary atherosclerosis were studied. Serial N-13 ammonia imaging was performed at rest and during supine bicycle exercise. The results were compared with those from 10 normal volunteers with a low probability of having cardiac disease. A two-compartment kinetic model for estimating myocardial perfusion was applied to the data. Transplant recipients achieved a significant lower exercise work load than did the volunteers (42 ± 16 vs. 128 ± 22 W), but a higher venous lactate concentration (31.3 ± 14.9 vs. 13.7 ± 4.1 mg/100 ml). Despite the difference in exercise work load, there was no significant difference in the cardiac work achieved by transplant recipients and normal subjects as evidenced by similar rate-pressure products of 24,000 ± 3,400 versus 21,300 ± 2,800 betas/min per mm Hg, respectively. In addition, myocardial blood flow during exercise was not significantly different between the two groups (1.70 ± 0.60 vs. 1.56 ± 0.71 ml/min per g, respectively). This study demonstrates that the myocardial flow response to the physiologic stress of exercise is appropriate in transplant recipients and does not appear to explain the decreased exercise capacity in these patients

  10. Assessment of chest pain in hypertrophic cardiomyopathy using exercise thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Maisey, M.; Curry, P.; Sowton, E.

    1980-01-01

    Exercise thallium-201 myocardial scintigraphy was performed in 23 patients with hypertrophic cardiomyopathy. Eighteen patients presented with chest pain which was a persistent symptom in 11. Selective coronary arteriography was performed in 16 patients and showed normal coronary arteries in 15 and insignificant luminal irregularities in one patient. Eighteen patients had abnormal scintigrams. Three had an abnormal distribution of tracer entirely attributable to asymmetric septal hypertrophy, whereas 15 had discrete tracer uptake defects which could not be explained solely by myocardial hypertrophy. In this latter group of patients three scintigraphic patterns were identified: (1) in 10 patients defects were seen in scintigrams immediately after exercise but not in delayed images obtained four to six hours later. Eight of these patients had chest pain. (2) Four patients had uptake defects seen in both initial and delayed images. One patient had chest pain. (3) In three patients, one of whom had chest pain, tracer defects were seen only in delayed images and were not apparent in the initial scintigrams. Chest pain occurred in eight out of 10 patients with scintigraphic evidence of myocardial ischaemia but was present in only three out of 13 patients with non-ischaemic scintigrams. The value of exercise thallium-201 myocardial imaging as a diagnostic technique in hypertrophic cardiomyopathy appears limited. Scintigraphic evidence of regional myocardial ischaemia in the absence of significant coronary artery disease, however, contributes to an understanding of the mechanism of angina production in patients with hypertrophic cardiomyopathy. (author)

  11. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  12. Correction for patient and organ movement in SPECT: application to exercise thallium-201 cardiac imaging

    International Nuclear Information System (INIS)

    Geckle, W.J.; Frank, T.L.; Links, J.M.; Becker, L.C.

    1988-01-01

    We describe a technique for correction of artifacts in exercise 201 Tl single photon emission computed tomography (SPECT) images arising from abrupt or gradual translational movement of the heart during acquisition. The procedure involves the tracking of the center of the heart in serial projection images using an algorithm which we call diverging squares. Each projection image is then realigned in the x-y plane so that the heart center conforms to the projected position of a fixed point in space. The shifted projections are reconstructed using the normal filtered backprojection algorithm. In validation studies, the motion correction procedure successfully eliminated movement artifacts in a heart phantom. Image quality was also improved in over one-half of 36 exercise thallium patient studies. The corrected images had smoother and more continuous left ventricular walls, greater clarity of the left ventricular cavity, and reduced streak artifacts. Rest injected or redistribution images, however, were often made worse, due to reduced heart to liver activity ratios and poor tracking of the heart center. Analysis of curves of heart position versus projection angle suggests that translation of the heart is common during imaging after exercise, and results from both abrupt patient movements, and a gradual upward shift of the heart. Our motion correction technique appears to represent a promising new approach for elimination of movement artifacts and enhancement of resolution in exercise 201 Tl cardiac SPECT images

  13. Clinical value and severity of myocardial perfusion defects in asymptomatic diabetic patients with negative or weakly positive exercise treadmill test

    International Nuclear Information System (INIS)

    Zakavi, Seyed Rasoul; Taherpour, Mehdi; Moossavi, Zohreh; Sadeghi, Ramin; Kakhki, Vahidreza Dabbagh; Rokni, Haleh

    2013-01-01

    Although coronary artery disease (CAD) is the leading cause of death in type 2 diabetic patients, it is frequently asymptomatic. Myocardial perfusion imaging (MPI) is reported to show ischemia in a significant number of asymptomatic diabetic patients. We studied the prevalence and severity of myocardial perfusion defects in asymptomatic diabetic patients and its clinical impact. One hundred thirty consecutive asymptomatic patients, aged 35-65 years with type 2 diabetes mellitus and with no history of CAD and no cardiac symptoms were recruited in the study. Echocardiography, electrocardiography (ECG), routine laboratory tests and exercise treadmill test (ETT) were performed and patients with weakly positive or negative ETT underwent Dipyridamole MPI. Patients with positive ETT were referred to coronary angiography. Patients were followed for at least 17 months (mean 21.7 months) and any cardiac event was recorded. We studied 81 female and 49 male patients with mean age of 51.8 years. Negative, weakly positive and positive ETT result was noted in 74.3%, 15% and 10.7% respectively. 75% of patients with positive ETT had coronary artery disease in angiography. Gated myocardial perfusion SPECT was done in 106 patients. MPI showed reversible defect in 26.9% of the patients with a mean summed stress score of 3.3±1.8. Follow up completed in 112 patients and only one patient with abnormal MPI underwent coronary angiography followed by PTCA. No cardiac death, MI, UA or hospital admission occurred among our patients during follow up (17-26 months). Mean stress end diastolic volume (EDV) was significantly higher in patients with reversible defect compared to patients without reversible defect based on MPI findings (62.0±31.6 Vs 48.5±18.4 ml, P=0.04). Blood glucose and HbA1c were significantly higher in patients with ischemia compared to patients without ischemia (P<0.05). Meanwhile the ratio of TG to HDL was 6.06±3.2 in ischemic patients compared to 4.8±2.3 in normal

  14. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  15. Improved detection of fill-in using sublingual nitroglycerin in technetium-99m tetrofosmin exercise/rest single photon emission computed tomography one day protocol for old myocardial infarction

    International Nuclear Information System (INIS)

    Miyanaga, Hajime; Kunieda, Yasufumi; Oguni, Atsuhiko; Kamitani, Tadaaki; Kawasaki, Shingo; Takahashi, Toru

    1999-01-01

    Twenty-one patients with old myocardial infarction underwent repeated 99m Tc-tetrofosmin ( 99m Tc) exercise/rest same day protocols with and without the administration of sublingual nitroglycerin (NTG) 5 min before the second injection of 99m Tc for rest SPECT. Twelve of these patients also underwent ordinary exercise/redistribution 201 Tl SPECT. The control study protocol images showed decreased uptake of 99m Tc on exercise in 157 of 420 segments and the presence of fill-in at rest in 58 segments. Images obtained with administration of NTG showed decreased uptake of 99m Tc on exercise in 163 of 420 segments and fill-in in 74 segments at rest. The frequency of fill-in was greater in the NTG protocol than in the control protocol. The segments were scored as different grades according to 99m Tc uptake between 2 protocols. Fill-in was only present or more remarkable in 31 segments in the NTG protocol than in the control protocol. Fill-in was only present or more remarkable in 10 segments in the control protocol than in the NTG protocol. In the NTG protocol, the mean defect score of the exercise images, calculated from the bull's eye image automatically, was higher than that of the rest images. The mean severity score of the exercise images, also calculated from the bull's eye image automatically, was likewise higher than that of the rest images, whereas the mean severity score of the stress images and rest images in the control protocol was not significantly different. Moreover, the mean defect score and severity score of the rest images from the NTG protocol were significantly lower than those obtained from the control protocol. Sublingual NTG administration before the injection of 99m Tc-tetrofosmin at the rest study in the one day exercise/rest studies enhanced fill-in, so may enhance the detection of viable myocardium, allowing more informed decisions regarding cardiac revascularization in patients with chronic coronary artery disease. (K.H.)

  16. Prognostic significance of stress myocardial gated SPECT among Japanese patients referred for coronary angiography: A study of data from the J-ACCESS database

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Mitsuru [Tokyo Women' s Medical University, Department of Radiology, Tokyo (Japan); Nakajima, Kenichi [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa (Japan); Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science, Kyoto (Japan)

    2009-08-15

    The J-ACCESS [Japanese investigation of prognosis based on gated single photon emission computed tomography (SPECT)] study found that quantitative gated myocardial SPECT (QGS) is valuable for predicting the prognosis of Japanese patients with known or suspected ischaemic heart disease. The present study evaluates the incremental prognostic value of myocardial perfusion imaging (MPI) with QGS among patients referred for coronary angiography (CAG). Among 4,031 Japanese patients registered at 117 hospitals for the J-ACCESS study, we selected 1,011 who underwent CAG within 3 months before or after MPI with QGS. Summed stress, rest and difference scores (SSS, SRS and SDS) were generated from myocardial perfusion images using a 20-segment scoring system. Myocardial ischaemia was judged visually. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were determined by QGS. Numbers of diseased (> 75% stenosis) coronary vessels (CDV) were assessed by CAG. All patients were followed up for 3 years to determine cardiac events (CE) including cardiac death, non-fatal myocardial infarction and severe heart failure. Univariate and multivariate analyses of prognostic ability included age, cardiac risk factors (hypertension, hyperlipidaemia, diabetes mellitus and prior myocardial infarction), angiographic findings and the QGS parameters as independent variables. Cardiac events occurred more frequently with increasing numbers of coronary vessel lesions (p=0.0016). Cox univariate analysis revealed that diabetes, CDV, SSS, SDS, EDV, ESV and EF were significant predictors (Wald {chi}{sup 2}=5.99, 12.9, 8.39, 9.11, 35.5, 42.1 and 31.1, respectively), whereas multivariate analysis selected only ESV and SDS as significant predictors (Wald {chi}{sup 2}=36.4, 8.4; p = 0.0038, p < 0.001). MPI with QGS, especially with gated functional data, has incremental prognostic value in addition to angiographic findings. MPI with QGS findings predominantly contribute to the

  17. Novel SPECT Technologies and Approaches in Cardiac Imaging

    Directory of Open Access Journals (Sweden)

    Piotr Slomka

    2016-12-01

    Full Text Available Recent novel approaches in myocardial perfusion single photon emission CT (SPECT have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.

  18. Estimation of myocardial flow reserve utilizing an ultrafast cardiac SPECT: Comparison with coronary angiography, fractional flow reserve, and the SYNTAX score.

    Science.gov (United States)

    Miyagawa, Masao; Nishiyama, Yoshiko; Uetani, Teruyoshi; Ogimoto, Akiyoshi; Ikeda, Shuntaro; Ishimura, Hayato; Watanabe, Emiri; Tashiro, Rami; Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Mochizuki, Teruhito

    2017-10-01

    Quantitative assessment of myocardial flow reserve (MFR) by single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is challenging but may facilitate evaluation of multi-vessel coronary artery disease (CAD). We enrolled 153 patients with suspected or known CAD, referred for pharmacological stress MPI. They underwent a 99m Tc-perfusion stress/rest SPECT with an ultrafast cadmium-zinc-telluride (CZT) camera. Dynamic data were acquired and time-activity curves fitted to a 1-tissue compartment analysis with input function. K1 was assigned for stress and rest data. The MFR index (MFRi) was calculated as K1 stress/K1 at-rest. The findings were validated by invasive coronary angiography in 69 consecutive patients. The global MFRi was 1.46 (1.16-1.76), 1.33 (1.12-1.54), and 1.18 (1.01-1.35), for 1-vessel disease (VD), 2-VD, and 3-VD, respectively. In the 3-VD, global MFRi was lower than that in 0-VD (1.63 [1.22-2.04], Pfraction (OR: 61.6 [57.5-66.0]), and global MFRi (OR: 119.6 [111.5-127.7], P=0.002). A cut-off value of 1.3 yielded 93.3% sensitivity and 75.9% specificity for diagnosing 3-VD. Fractional flow reserve positively correlated with regional MFRi (r=0.62, P=0.008), and the SYNTAX score correlated negatively with global MFRi (r=0.567, P=0.0003). We developed and validated a clinically available method for MFR quantification by dynamic 99m Tc-perfusion SPECT utilizing a CZT camera, which improves the detectability of multi-vessel CAD. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Thallium 201 Exercise Scintigraphy for Detection of Multivessel Coronary Artery Disease After Transmural Myocardial Infarction

    Science.gov (United States)

    Ahmadpour, Hedayatolah; Siegel, Michael E.; Colletti, Patrick; Haywood, L. Julian

    1984-01-01

    Fifty patients with prior transmural myocardial infarction were studied with cardiac catheterization, coronary angiography, and thallium 201 exercise perfusion scintigraphy. Obstructive coronary disease involved two or three vessels in 37 patients. The sensitivity of a positive electrocardiographic test during exercise for detecting multivessel coronary disease was only 40 percent (15/37), and the sensitivity of a reversible defect on 201Tl perfusion scintigraphy was 48 percent (18/37). The combination of exercise testing and 201Tl scintigraphy detected multivessel coronary disease in 75 percent (28/37) (P < .05). New perfusion defects occurred in 61 percent (13/21) of patients with inferior myocardial infarction and multivessel coronary disease whereas it occurred in only 35 percent (5/14) of patients with prior anterior infarction and multivessel coronary disease (P < .05). 201Tl exercise perfusion scintigraphy appears to be more sensitive for detecting significant multivessel coronary disease in the presence of previous inferior infarction compared with previous anterior infarction. Combined graded exercise testing and 201Tl perfusion scintigraphy can reliably detect the presence of significant multivessel coronary disease after transmural myocardial infarction. ImagesFigure 3 PMID:6512876

  20. Improvement of myocardial perfusion detected by 201Tl scintigraphy on cardiac rehabilitation for patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li, Linxue; Nohara, Ryuji; Makita, Shigeru

    1996-01-01

    The effect of cardiac rehabilitation (mean 70±48 months) on myocardial perfusion was assessed using thallium-201 ( 201 Tl) exercise study in 63 patients with coronary artery disease (CAD). Subjects were those in a rehabilitation group (Rh=42) participating in supervised sports training two to three times per week and the control group (Ct=21) not taking active daily exercise. The interval between two 201 Tl SPECT studies was 19±16 months. After physical training, total duration of the exercise test increased from 443±112 to 536±121 seconds (+19%) in the Rh group, and from 484±129 to 432±115 seconds in the Ct group (-10.7%) (p 2 to 269.8±58 x 10 2 in the Rh group and decreased from 218.7±40 x 10 2 to 216.6±76 x 10 2 (p 201 Tl myocardial perfusion defect on exercise improved more in 54.8% (stress 59.5%, rest 35.7%) in the Rh group than in the Ct group (9.5%, p 201 Tl perfusion defect decreased from 68 (23.1%) to 49 regions (16.7%) of 294 total myocardial regions in the Rh group on exercise. However. it increased from 39 (26.5%) to 44 (29.9%) regions of 147 regions in the Ct group (p<0.01). Thus, cardiac rehabilitation increases exercise tolerance with improvement of myocardial perfusion. suggesting that cardiac rehabilitation is an advisable and effective treatment for patients with ischemic heart disease. (author)

  1. Silent myocardial ischemia in patients with symptomatic intracranial atherosclerosis: associated factors.

    Science.gov (United States)

    Arenillas, Juan F; Candell-Riera, Jaume; Romero-Farina, Guillermo; Molina, Carlos A; Chacón, Pilar; Aguadé-Bruix, Santiago; Montaner, Joan; de León, Gustavo; Castell-Conesa, Joan; Alvarez-Sabín, José

    2005-06-01

    Optimization of coronary risk evaluation in stroke patients has been encouraged. The relationship between symptomatic intracranial atherosclerosis and occult coronary artery disease (CAD) has not been evaluated sufficiently. We aimed to investigate the prevalence of silent myocardial ischemia in patients with symptomatic intracranial atherosclerosis and to identify factors associated with its presence. From 186 first-ever transient ischemic attack or ischemic stroke patients with intracranial stenoses, 65 fulfilled selection criteria, including angiographic confirmation of a symptomatic atherosclerotic stenosis and absence of known CAD. All patients underwent a maximal-stress myocardial perfusion single-photon emission computed tomography (SPECT). Lipoprotein(a) [Lp(a)], C-reactive protein, and homocysteine (Hcy) levels were determined before SPECT. Stress-rest SPECT detected reversible myocardial perfusion defects in 34 (52%) patients. Vascular risk factors associated with a pathologic SPECT were hypercholesterolemia (P=0.045), presence of >2 risk factors (P=0.004) and high Lp(a) (P=0.023) and Hcy levels (P=0.018). Ninety percent of patients with high Lp(a) and Hcy levels had a positive SPECT. Existence of a stenosed intracranial internal carotid artery (ICA; odds ratio [OR], 7.22, 2.07 to 25.23; P=0.002) and location of the symptomatic stenosis in vertebrobasilar arteries (OR, 4.89, 1.19 to 20.12; P=0.027) were independently associated with silent myocardial ischemia after adjustment by age, sex, and risk factors. More than 50% of the patients with symptomatic intracranial atherosclerosis and not overt CAD show myocardial perfusion defects on stress-rest SPECT. Stenosed intracranial ICA, symptomatic vertebrobasilar stenosis and presence of high Lp(a) and Hcy levels may characterize the patients at a higher risk for occult CAD.

  2. Usefulness of 99mTc-MIBI stress myocardial SPECT Bull's-eye quantification incoronary artery disease

    International Nuclear Information System (INIS)

    Rubello, D.; Zanco, P.; Borsato, N.; Chierichetti, F.; Saitta, B.; Ferlin, G.; Candelpergher, G.; Minello, S.

    1995-01-01

    99m Tc-methoxy-isobutyl isonitrile (MIBI) myocardial SPECT quantification performed using a Bull's-eye polar map, was evaluated and compared with visual analysis in 120 patients with proven or suspected CAD. The study series comprised 106 men and 14 women, age 37-75 years, 68 of whom had had a prior myocardial infarction. Coronary angiography was taken as the gold standard. Forty age-matched subjecs, with less than a 5% chance of having CAD, were enrolled to establish the normal database for males and females. ROC analysis was used to calculate the optimal thresholds for the definition of the disease extension in each vascular territory of the Bull's-eye polar map. Bull's-eye analysis agreed with visual analysis in 296/360 vessels. Two and three-vessel disease were most frequently observed using the Bull's-eye approach. However, a greater number of false positive (FP) cases were found with Bull's-eye than with visual analysis (28 versus 3 cases): FP cases were detected principally (21/28) in patients with previous myocardial infarction. It is interesting to note that this phenomenon, commonly observed in the LCX or RCA territory, was almost always correctly interpreted as a FP case by visual analysis. In conclusion, it is found the sensitivity and specificity for CAD diagnosis with the Bull's-eye approach to be similar to that of visual analysis, but the former method seems to be somewhat more sensitive for the localization of LAD and LCX disease. However, particular attention should be paid to patients with previous myocardial infarction, as FP cases are not infrequently observed with quantitative analysis, especially in the LCX and RCA territories

  3. Operative characteristics of rest myocardial perfusion in emergency thoracic pain evaluation

    International Nuclear Information System (INIS)

    Merlano G, Sonia; Murgueitio C, Ramon; Rodriguez F, Edgard; Carvajal C, Andres; Suarez R, Martin

    2000-01-01

    Study objective: Conventional emergency department testing strategies for patients with chest pain often provide equivocal diagnosis of coronary artery disease. This study was conducted to determine the sensibility, specificity , positive predictive value (PPV), negative predictive value (NPV) and Likelihood ratio LR(-) of the myocardial perfusion imaging with single photon emission computed tomography (SPECT) imaging at rest. Methods: We design a diagnostic imaging protocol to evaluate clinical usefulness of SPECT Technetium sestamibi imaging at rest in patients with typical and atypical chest pain and normal or non diagnostic electrocardiogram. Coronary angiogram was the gold standard for positive studies and six month follow up after completing the exercise test for negatives. Nuclear Medicine physicians were unaware of the angiograms results. The inter observers variability was measure with a Kappa coefficient. Results: We enrolled 107 patients 78 males (72.8%) and 29 females (27.2%). We found sensitivity 95.45% (IC 95% 95.41-95.48), specificity 92.94%(IC 95% 92.9- 92.98) Negative predictive value 98.75% LR(-) 0.092 . The study adequately classified 93% of the patients. Kappa coefficient for concordance between observer was 0.95 Conclusion: Myocardial perfusion imaging with SPECT at rest, has a high negative predictive value and a very good ability to classify normal patients as such and therefore may be use for the assessment of patients with chest pain and normal or non diagnostic electrocardiograms at the emergency room (Au)

  4. Pretest clinical diagnosis of coronary artery disease and stress myocardial perfusion scintigram

    International Nuclear Information System (INIS)

    Kasalicky, J.; Kovac, I.; Lanska, V.

    2001-01-01

    To assess the probability of perfusion defects at exercise stress myocardial perfusion SPECT scintigraphy from pretest clinical diagnosis (medical personal history, previous ergometric investigation). To determine the value of clinical factors for probability of scintigraphic defects with respect to avoiding unnecessary investigation in subjects with low probability of abnormal scintigrams. 2143 subjects (1235 men, 908 women) were investigated by SPECT perfusion scintigraphy at stepwise increasing exercise stress. They were divided into three groups with regard to their medical history and exercise test at scintigraphy: subjects without any signs of coronary artery disease (CAD), patients with high likelihood of CAD (i.e., typical anginal pain, in particular at stress, positive stress ECG changes, angiographically documented important CAD) and patients after myocardial infarction (MI). Important risk factors (hypertension, diabetes, age and sex), as well as the role of revascularisation procedures, were taken into account for multiple logistic regression in order to express their importance for the odds of scintigraphic defect visualisation. Perfusion scintigraphic defects (PSD) were found in 5.2% of subjects without signs of CAD, in contrast to patients with manifest CAD (68.8% with PSD) and in those after MI (90.2% with PSD). There were other important factors corroborating the likelihood of PSD (in decreasing order of importance): diabetes, male, ECG changes at stress, increasing age. Successful revascularisation improved scintigraphic images. The examination of CAD symptom-free subjects, in particular with atypical chest discomfort, is useless. SMPS in patients after documented MI is to be carried out for other intended purposes, not for CAD diagnosis only. SMPS is highly recommended in patients with CAD symptoms and high CAD probability in order to decide further treatment and prognosis. (author)

  5. Comparative assessment of 18F-fluorodeoxyglucose PET and 99mTc-tetrofosmin SPECT for the prediction of functional recovery in patients with reperfused acute myocardial infarction

    International Nuclear Information System (INIS)

    Shirasaki, Haruhisa; Nakano, Akira; Uzui, Hiroyasu; Ueda, Takanori; Lee, Jong-Dae; Yonekura, Yoshiharu; Okazawa, Hidehiko

    2006-01-01

    Purpose: Although preserved glucose metabolism is considered to be a marker of myocardial viability in the chronic stage, it has not been fully elucidated whether this is also true with regard to reperfused acute myocardial infarction (AMI). The aim of this study was to compare the diagnostic performance of 99m Tc-tetrofosmin SPECT and 18 F-fluorodeoxyglucose (FDG) PET for the prediction of functional recovery in reperfused AMI.Methods: The study population comprised 28 patients. Both tetrofosmin SPECT and FDG PET were performed in all 28 patients at ca. 2 weeks and in 23 at 6 months. The tetrofosmin and FDG findings in infarct-related segments were compared with the regional wall motion score assessed by left ventriculography over 6 months to determine the predictive value for functional recovery. Of 120 infarct-related segments, 83 had preserved flow (tetrofosmin uptake ≥50%) and 81 had preserved glucose metabolism (FDG uptake ≥40%). The sensitivity and specificity of tetrofosmin SPECT for the prediction of functional recovery tended to be superior to those of FDG PET (90.0% and 72.5% vs 85.0% and 67.5%, respectively). Thirteen segments with preserved flow and decreased glucose metabolism demonstrated marked recovery of contractile function from 2.5±1.0 to 1.4±1.4 (p<0.01), with restoration of glucose metabolism at 6 months. In contrast, 11 segments with decreased flow and preserved glucose metabolism demonstrated incomplete functional improvement from 3.0±0.8 to 2.2±1.2. In the subacute phase, preserved myocardial blood flow is more reliable than glucose metabolism in predicting functional recovery in reperfused myocardium. (orig.)

  6. Predictability of psychic outcome for exercise training and exercise training including relaxation therapy after myocardial infarction

    NARCIS (Netherlands)

    H.J. Duivenvoorden (Hugo); J. van Dixhoorn (J.)

    1991-01-01

    markdownabstractAbstract Predictability of the psychic outcome for two cardiac rehabilitation programmes was investigated in 119 myocardial infarction patients. They were randomly assigned to either a five-week daily exercise training or to an identical training in combination with six sessions

  7. Early diagnosis of interferon-induced myocardial disorder in patients with chronic hepatitis C. Evaluation by myocardial imaging with {sup 123}I-BMIPP

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Yuki; Yukinaka, Michiko; Nomura, Masahiro; Nakaya, Yutaka; Ito, Susumu [Tokushima Univ. (Japan). School of Medicine

    2000-02-01

    Interferon (IFN) therapy for chronic hepatitis C is sometimes associated with cardiac complications. In the present study, we performed myocardial imaging with {sup 123}I-labeled {beta}-methyl-p-iodophenylpentadecanoic acid ({sup 123}I-BMIPP) in order to evaluate myocardial disorders caused by IFN. We studied 40 healthy subjects (H group) and 25 patients with chronic hepatitis C who had been treated with IFN (IFN group). A Holter electrocardiogram (ECG) was performed and the autonomic nervous function was assessed by analyzing the spectral variability and 1/f fluctuation of heart rate. Myocardial planner imaging with {sup 123}I-BMIPP was performed to obtain the time activity curve for 20 min immediately after administration of {sup 123}I-BMIPP (dynamic study). Early and delayed myocardial single photon emission computed tomography (SPECT) images were expressed as Bull's eyes and the myocardium was divided into four segments to calculate the washout rate for each segment on early and late SPECT images (early and late SPECT study). No significant differences in autonomic nervous function were observed between the two groups in heart rate variability. In a dynamic study, the reduction rate from the time activity curve was significantly higher in the IFN group compared with the H group (reduction rate, IFN group, 5.3{+-}3.7% vs H group, 1.2{+-}3.3%; P<0.05). In the early and delayed myocardial SPECT study, the washout rate for the IFN group was significantly increased in all myocardial areas compared to that in the H group. However, the metabolic disorder of fatty acids caused by IFN was reversed on the second {sup 123}I-BMIPP myocardial scintigraphy examination several months after IFN therapy. These results indicate that metabolic disorders of fatty acids caused by IFN therapy can be detected before abnormalities are observed by Holter-ECG or echocardiography. (author)

  8. Prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Lin JInghui; Zhang Chunli; Nie Tao; Wang Yanfu

    1998-01-01

    Purpose: To evaluate the prognostic value of abnormal exercise myocardial perfusion imaging and its types in patients with coronary artery disease (CAD). Methods: 69 patients with CAD underwent exercise myocardial perfusing imaging and exercise ECG test. The images of all of them were abnormal. 45 patients were angiographically proved CAD. Follow-up period ranged from 6∼110 months and even longer than 12 months for patients with no cardiac events (CE). Results: CE occurred in 15 patients during the follow-up period. The CE incidence was 8.7% per year. Cox regression analysis revealed that there was a good correlation between the number of myocardial segments with reversible defects and future CE. Comparing the results of 13 patients with small extent irreversible defects with the data obtained from normal subjects reported previously, there was no significant difference between two no-CE rates (x 2 = 0.09, P>0.05). Conclusions: Normal myocardial images and irreversible defects involving rather small areas predicted an excellent prognosis. The better predictor of future CE is the quantity of myocardial segments with reversible defect

  9. Early and delayed Tc-99m-tetrofosmin myocardial SPECT in patients with left bundle branch block

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Kinoshita, Noriyuki; Adachi, Yoshihiko

    1998-01-01

    To determine the utility of the myocardial tracer Tc-99m-tetrofosmin in the examination of patients with left bundle branch block (LBBB) and to investigate Tc-99m-tetrofosmin uptake and retention in the myocardium, early and delayed Tc-99m-tetrofosmin SPECT was performed in 10 patients having LBBB without coronary stenosis. After 740 MBq of Tc-99m-tetrofosmin injection in the resting state, the early and delayed SPECT imaging was done at 30 min and 180 min, respectively. Decreased Tc-99m-tetrofosmin uptake in the septal segments was observed in 4 patients (40%) at 30 min and in 9 (90%) at 180 min. Reverse redistribution was seen in 9 of 10 patients. In patients with LBBB, the septal-to-lateral uptake ratio was lower in the delayed images than in the early images (0.80±0.09 vs. 0.89±0.09, p<0.001). In patients with LBBB, the washout rate of Tc-99m-tetrofosmin was higher in the septal segments than in the lateral segments (28.3±4.3% vs. 22.8±3.3%, p<0.001). The SPECT data indicate that in LBBB without coronary stenosis, the uptake of Tc-99m-tetrofosmin is decreased in the septal wall, and that reverse redistribution occurs frequently. Our results contribute to the elucidation of both the cellular biokinetics of Tc-99m-tetrofosmin in the myocardium and the hemodynamics of the septum in LBBB, and indicate the possible clinical utility of Tc-99m-tetrofosmin. (author)

  10. Application of Three-Class ROC Analysis to Task-Based Image Quality Assessment of Simultaneous Dual-Isotope Myocardial Perfusion SPECT (MPS)

    OpenAIRE

    He, Xin; Song, Xiyun; Frey, Eric C.

    2008-01-01

    The diagnosis of cardiac disease using dual-isotope myocardial perfusion SPECT (MPS) is based on the defect status in both stress and rest images, and can be modeled as a three-class task of classifying patients as having no, reversible, or fixed perfusion defects. Simultaneous acquisition protocols for dual-isotope MPS imaging have gained much interest due to their advantages including perfect registration of the 201Tl and 99mTc images in space and time, increased patient comfort, and higher...

  11. FDG F18/Rest Tl 201 SPECT patterns in recent myocardial infarction. Predictive value for regional function recovery

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa [Universidad de Chile, Hospital Clinico. Centro de Medicina Nuclear, Santiago (Chile); Gonzalez, Patricio; Coll, Claudia; Yovanovich, Jorge; Jofre, M Josefina; Humeres, Pamela; Sierralta, Paulina; Chamorro, Hernan; Ramirez, Alfredo; Kunstmann, Sonia; Lopez, Hector; Aramburu, Ivonne; Bru, Solange [Universidad de Chile, Santiago (Chile). Hospital Clinico. Centros de Medicina Nuclear e Cardiovascular; Clinica Santa Maria, Santiago [Chile

    2003-04-01

    Background: detecting viability is important after recent myocardial infarction (MI). SPECT FDG/Tl flow-metabolism patterns for predicting functional recovery were analyzed in this setting. Method: forty-one patients were studied (56+-12 years; 80% males) with Tl 201 at rest and FDG F 18 SPECT at a mean of 8.9 days post MI (range:1-24). All had baseline and 3 month follow-up echocardiography (Echo) and initial coronary angiography. They were submitted to primary PTCA in 12 cases, late PTCA in 15 and bypass surgery in 10 and thrombolysis was performed in 4 patients as only procedure. A total of 345 culprit artery territory segments were interpreted by 3 nuclear independent observers. Analysis included segments with or without abnormal motion. Results: FDG/Tl 201 on patient basis, had: sensitivity 91%; specificity 56%; positive predictive value 88 %; negative predictive value (NPV) 63% and accuracy 83%. The analysis of segments with abnormal contractility showed values of 67%, 69%, 44%, 85% and 68%, respectively. Reverse mismatch with FDG/Tl appears to predict viability similarly to classical mismatch; severe or moderate match was highly associated with no functional recovery (NPV 85%). Conclusion: flow-perfusion patterns are variable in recent MI. FDG/Tl 201 SPECT has acceptable accuracy for predicting functional recovery and excellent NPV to further exclude viability (author)

  12. FDG F18/Rest Tl 201 SPECT patterns in recent myocardial infarction. Predictive value for regional function recovery

    International Nuclear Information System (INIS)

    Massardo, Teresa; Gonzalez, Patricio; Coll, Claudia; Yovanovich, Jorge; Jofre, M. Josefina; Humeres, Pamela; Sierralta, Paulina; Chamorro, Hernan; Ramirez, Alfredo; Kunstmann, Sonia; Lopez, Hector; Aramburu, Ivonne; Bru, Solange; Clinica Santa Maria, Santiago

    2003-01-01

    Background: detecting viability is important after recent myocardial infarction (MI). SPECT FDG/Tl flow-metabolism patterns for predicting functional recovery were analyzed in this setting. Method: forty-one patients were studied (56+-12 years; 80% males) with Tl 201 at rest and FDG F 18 SPECT at a mean of 8.9 days post MI (range:1-24). All had baseline and 3 month follow-up echocardiography (Echo) and initial coronary angiography. They were submitted to primary PTCA in 12 cases, late PTCA in 15 and bypass surgery in 10 and thrombolysis was performed in 4 patients as only procedure. A total of 345 culprit artery territory segments were interpreted by 3 nuclear independent observers. Analysis included segments with or without abnormal motion. Results: FDG/Tl 201 on patient basis, had: sensitivity 91%; specificity 56%; positive predictive value 88 %; negative predictive value (NPV) 63% and accuracy 83%. The analysis of segments with abnormal contractility showed values of 67%, 69%, 44%, 85% and 68%, respectively. Reverse mismatch with FDG/Tl appears to predict viability similarly to classical mismatch; severe or moderate match was highly associated with no functional recovery (NPV 85%). Conclusion: flow-perfusion patterns are variable in recent MI. FDG/Tl 201 SPECT has acceptable accuracy for predicting functional recovery and excellent NPV to further exclude viability (author)

  13. Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation.

    Science.gov (United States)

    Berman, Daniel S; Abidov, Aiden; Kang, Xingping; Hayes, Sean W; Friedman, John D; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Waechter, Parker B; Germano, Guido; Hachamovitch, Rory

    2004-01-01

    Recently, a 17-segment model of the left ventricle has been recommended as an optimally weighted approach for interpreting myocardial perfusion single photon emission computed tomography (SPECT). Methods to convert databases from previous 20- to new 17-segment data and criteria for abnormality for the 17-segment scores are needed. Initially, for derivation of the conversion algorithm, 65 patients were studied (algorithm population) (pilot group, n = 28; validation group, n = 37). Three conversion algorithms were derived: algorithm 1, which used mid, distal, and apical scores; algorithm 2, which used distal and apical scores alone; and algorithm 3, which used maximal scores of the distal septal, lateral, and apical segments in the 20-segment model for 3 corresponding segments of the 17-segment model. The prognosis population comprised 16,020 consecutive patients (mean age, 65 +/- 12 years; 41% women) who had exercise or vasodilator stress technetium 99m sestamibi myocardial perfusion SPECT and were followed up for 2.1 +/- 0.8 years. In this population, 17-segment scores were derived from 20-segment scores by use of algorithm 2, which demonstrated the best agreement with expert 17-segment reading in the algorithm population. The prognostic value of the 20- and 17-segment scores was compared by converting the respective summed scores into percent myocardium abnormal. Conversion algorithm 2 was found to be highly concordant with expert visual analysis by the 17-segment model (r = 0.982; kappa = 0.866) in the algorithm population. In the prognosis population, 456 cardiac deaths occurred during follow-up. When the conversion algorithm was applied, extent and severity of perfusion defects were nearly identical by 20- and derived 17-segment scores. The receiver operating characteristic curve areas by 20- and 17-segment perfusion scores were identical for predicting cardiac death (both 0.77 +/- 0.02, P = not significant). The optimal prognostic cutoff value for either 20

  14. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation.

    Science.gov (United States)

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H; Gullberg, Grant T

    2017-02-01

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99m Tc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99m Tc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99m Tc-tefrofosmin using SPECT and MBF values estimated with 13 N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13 N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99m Tc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99m Tc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2  = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99m Tc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99m Tc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.

  15. Relationship between the mismatch of 123I-BMIPP and 201Tl myocardial single-photon emission computed tomography and autonomic nervous system activity in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Yamanaka, Hiroyuki; Suzuki, Takeshi; Kishida, Hiroshi; Nagasawa, Koichi; Takano, Teruo

    2006-01-01

    The purpose of this study was to elucidate the relationship between the mismatch of thallium-201 (Tl) and iodine-123-beta-methyl-iodophenyl-pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography (SPECT) and autonomic nervous system activity in myocardial infarction (MI) patients. The subjects were 40 patients (34 males, 6 females) who underwent examinations by 123 I-BMIPP and 201 Tl myocardial SPECT imaging and 24-hour Holter monitoring within a 3-day period 3 weeks after the onset of their first MI. R-R intervals were analyzed every hour over a period of 24 hours by fast Fourier transformation (FFT). High frequency (HF) and low frequency (LF) were defined as markers of cardiac vagal activity in the former and the LF/HF ratio as sympathetic activity. Greater or more extensive decreases in the BMIPP image than that in the Tl image were defined as a positive mismatch. Patients were divided into positive and negative mismatch groups of 20 patients each. There were no significant differences between the 2 groups in age, sex, site of infarction, max CK (creatine kinase), max CK-MB, or left ventricular ejection fraction. The incidences of clinical signs suggesting residual myocardial ischemia were significantly greater in the positive than in the negative mismatch group (P 123 I-BMIPP and 201 Tl myocardial SPECT 3 weeks after a first acute myocardial infarction with uncomplicated moderate or severe heart failure and decreased heart rate variability are related to residual myocardial ischemia. A combined assessment of heart rate variability in 24 hour Holter electrocardiogram (ECG) monitoring and perfusion-metabolism mismatch in 123 I-BMIPP and 201 Tl myocardial SPECT is useful for determining residual myocardial ischemia in the follow-up of those with acute myocardial infarction. (author)

  16. Quantitative Assessment of Myocardial Infarction by In-111 Antimyosin Antibody

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Lee, Kyung Han; Choi, Yoon Ho; Chung, June Key; Park, Young Bae; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of); Moon, Dae Hyuk [Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1991-03-15

    Infarct size is a major determinant of prognosis after acute myocardial infarction. Up to date, however, clinically available tests to estimate this size have not been sufficiently accurate. Twelve lead electrocardiogram and wall motion abnormality measurement are not quantitative, and creatine phosphokinase (CPK) measurement is inaccurate in the presence of reperfusion or right ventricular infarction. Methods have been developed to localize and size acute myocardial infarcts with agents that are selectively sequestered in areas of myocardial damage, but previously used agents have lacked sufficient specificity. Antibodies that bind specifically only to damaged myocardial cells may resolve this problem and provide an accurate method for noninvasively measuring infarct size. We determined the accuracy with which infarcted myocardial mass can be measured using single photon emission computed tomography (SPECT) and radiolabeled antimyosin antibodies. Seven patients with acute myocardial infarction and one stable angina patient were injected with 2 mCi of Indium-111 labeled antimyosin antibodies. Planar image and SPECT was performed 24 hours later. None of the patients had history of prior infarcts, and none had undergone reperfusion techniques prior to the study, which was done within 4 days of the attack. Planar image showed all infarct patients to have positive uptakes in the cardiac region. The location of this uptake correlated to the infarct site as indicated by electrocardiography in most of the cases. The angina patient, however, showed no such abnormal uptake. Infarct size was determined from transverse slices of the SPECT image using a 45% threshold value obtained from a phantom study. Measured infarct size ranged from 40 to 192 gr. There was significant correlation between the infarct size measured by SPECT and that estimated from serial measurements of CPK (r=0.73, p<0,05). These date suggest that acute myocardial infarct size can be accurately measured

  17. Prognostic Value of Normal Perfusion but Impaired Left Ventricular Function in the Diabetic Heart on Quantitative Gated Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanjeong; Choi, Sehun; Han, Yeonhee [Research Institute of Chonbuk National Univ. Medical School and Hospitial, Jeonju (Korea, Republic of); Lee, Dong Soo; Lee, Hoyoung; Chung, Junekey [Seoul National Univ., Seoul (Korea, Republic of)

    2013-09-15

    This study aimed at identifying the predictive parameters on quantitative gated myocardial perfusion single-photon emission computed tomography (QG-SPECT) in diabetic patients with normal perfusion but impaired function. Methods Among the 533 consecutive diabetic patients, 379 patients with normal perfusion on rest Tl-201/dipyridamole-stress Tc-{sup 99m} sestamibi Gated SPECT were enrolled. Patients were grouped into those with normal post-stress left ventricular function (Group I) and those with impaired function (EF <50 or impaired regional wall motion, Group II). We investigated cardiac events and cause of death by chart review and telephone interview. Survival analysis and Cox proportional hazard model analysis were performed. Between the Group I and II, cardiac events as well as chest pain symptoms, smoking, diabetic complications were significantly different (P<0.05). On survival analysis, event free survival rate in Group II was significantly lower than in Group I (P=0.016). In univariate Cox proportional hazard analysis on overall cardiac event, Group (II over I), diabetic nephropathy, summed motion score (SMS), summed systolic thickening score (STS), numbers of abnormal segmental wall motion and systolic thickening predicted more cardiac events (P<0.05). Multivariate analysis showed that STS was the only independent predictor cardiac event. The functional parameter, especially summed systolic thickening score on QG-SPECT had prognostic values, despite normal perfusion, in predicting cardiac events in diabetic patients, and QG-SPECT provides clinically useful risk stratification in diabetic patients with normal perfusion.

  18. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks

    Science.gov (United States)

    Ghaly, Michael; Du, Yong; Links, Jonathan M.; Frey, Eric C.

    2016-03-01

    In SPECT imaging, collimators are a major factor limiting image quality and largely determine the noise and resolution of SPECT images. In this paper, we seek the collimator with the optimal tradeoff between image noise and resolution with respect to performance on two tasks related to myocardial perfusion SPECT: perfusion defect detection and joint detection and localization. We used the Ideal Observer (IO) operating on realistic background-known-statistically (BKS) and signal-known-exactly (SKE) data. The areas under the receiver operating characteristic (ROC) and localization ROC (LROC) curves (AUCd, AUCd+l), respectively, were used as the figures of merit for both tasks. We used a previously developed population of 54 phantoms based on the eXtended Cardiac Torso Phantom (XCAT) that included variations in gender, body size, heart size and subcutaneous adipose tissue level. For each phantom, organ uptakes were varied randomly based on distributions observed in patient data. We simulated perfusion defects at six different locations with extents and severities of 10% and 25%, respectively, which represented challenging but clinically relevant defects. The extent and severity are, respectively, the perfusion defect’s fraction of the myocardial volume and reduction of uptake relative to the normal myocardium. Projection data were generated using an analytical projector that modeled attenuation, scatter, and collimator-detector response effects, a 9% energy resolution at 140 keV, and a 4 mm full-width at half maximum (FWHM) intrinsic spatial resolution. We investigated a family of eight parallel-hole collimators that spanned a large range of sensitivity-resolution tradeoffs. For each collimator and defect location, the IO test statistics were computed using a Markov Chain Monte Carlo (MCMC) method for an ensemble of 540 pairs of defect-present and -absent images that included the aforementioned anatomical and uptake variability. Sets of test statistics were

  19. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  20. Reversible wall motion abnormality on adenosine stress/rest thallium-201 gated myocardial SPECT is an independent predictor of coronary artery disease

    International Nuclear Information System (INIS)

    Park, Eun Kyung; Lee, Won Woo; So, Young; Eo, Jae Seon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun; Kim, Cheol Ho; Lee, Sang Woo

    2004-01-01

    As early as 10 minutes after adenosine stress, immediate post-stress wall motion (ipsWM) can be evaluated on adenosine stress/rest TI-201 gated SPECT (gSPECT). To widen application of TI-201 in gated SPECT, we investigated image quality, LV parameters (EF, EDV, and ESV) reproducibility, and diagnostic competency of gSPECT regarding ipsWM evaluation Myocardial perfusion and wall motion were evaluated by 5-point scoring system in 20-segment model. Image quality was assessed using weighted Kappa (Kw) for inter-and intra-observer agreements of wall motion scores (n=49). Reproducibility was examined through repeated acquisition (n=31). Diagnostic competency was evaluated versus coronary angiography (CAG) and multivariate logistic regression analysis was performed to identify significant predictors of coronary artery disease (CAD) among stress abnormal perfusion (SSSp), stress abnormal wall motion (SSSwm), and reversible abnormal wall motion (SDSwm) (n=60). Kw for ipsWM was significantly better than that for rest regarding inter- (0.717 vs 0.489) and intra-observer agreements (0.792 vs 0.688) (p<0.05). 2SD for ipsWM was smaller than that for rest at EF (8.6% vs 10.7%) and ESV (6.0ml vs 8.4ml). Sensitivities of SSSp, SSSwm, and SDSwm were 63.3% (19/30), 63.3% (19/30), and 43.3% (13/30) and specificities 83.3% (25/30), 83.3% (25/30), and 86.7% (26/30), respectively. By multivariate analysis, SSSp (p=0.013) and SDSwm (p=0.039) remained significant predictors. Additionally, SSSwm or SDSwm could find undetected CAD in 54.5% (6/11) of patients with normal perfusion. TI-201 can be successfully applied to gated SPECT for ipsWM evaluation. Moreover, reversible wall motion abnormality on gSPECT is an independent predictor of significant CAD

  1. Iodophenylpentadecanoic acid-myocardial blood flow relationship during maximal exercise with coronary occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, J.H.; Martin, G.V.; Link, J.M.; Krohn, K.A.; Bassingthwaighte, J.B. (Seattle VA Medical Center, WA (USA))

    1990-01-01

    Imaging {sup 123}I-labeled iodophenylpentadecanoic acid (IPPA) uptake and clearance from the myocardium following exercise has been advocated as a means of detecting myocardial ischemia because fatty acid deposition is enhanced and clearance prolonged in regions of low flow. However, normal regional myocardial blood flows are markedly heterogeneous, and it is not known how this heterogeneity affects regional metabolism or substrate uptake and thus image interpretation. In five instrumented dogs running at near maximal workload on a treadmill, {sup 131}I-labeled IPPA and 15-micron 46Sc microspheres were injected into the left atrium after 30 sec of circumflex coronary artery occlusion. Microsphere and IPPA activity were determined in 250 mapped pieces of myocardium of approximately 400 mg. Myocardial blood flows (from microspheres) ranged from 0.05 to 7.6 ml/min/g. Deposition of IPPA was proportional to regional flows (r = 0.83) with an average retention of 25%. The mean endocardial-epicardial ratio for IPPA (0.90 {plus minus} 0.43) was similar to that for microspheres (0.94 {plus minus} 0.47; p = 0.08). Thus, initial IPPA deposition during treadmill exercise increases in proportion to regional myocardial blood flow over a range of flows from very low to five times normal.

  2. Iodophenylpentadecanoic acid-myocardial blood flow relationship during maximal exercise with coronary occlusion

    International Nuclear Information System (INIS)

    Caldwell, J.H.; Martin, G.V.; Link, J.M.; Krohn, K.A.; Bassingthwaighte, J.B.

    1990-01-01

    Imaging 123 I-labeled iodophenylpentadecanoic acid (IPPA) uptake and clearance from the myocardium following exercise has been advocated as a means of detecting myocardial ischemia because fatty acid deposition is enhanced and clearance prolonged in regions of low flow. However, normal regional myocardial blood flows are markedly heterogeneous, and it is not known how this heterogeneity affects regional metabolism or substrate uptake and thus image interpretation. In five instrumented dogs running at near maximal workload on a treadmill, 131 I-labeled IPPA and 15-micron 46Sc microspheres were injected into the left atrium after 30 sec of circumflex coronary artery occlusion. Microsphere and IPPA activity were determined in 250 mapped pieces of myocardium of approximately 400 mg. Myocardial blood flows (from microspheres) ranged from 0.05 to 7.6 ml/min/g. Deposition of IPPA was proportional to regional flows (r = 0.83) with an average retention of 25%. The mean endocardial-epicardial ratio for IPPA (0.90 ± 0.43) was similar to that for microspheres (0.94 ± 0.47; p = 0.08). Thus, initial IPPA deposition during treadmill exercise increases in proportion to regional myocardial blood flow over a range of flows from very low to five times normal

  3. Iodophenylpentadecanoic acid-myocardial blood flow relationship during maximal exercise with coronary occlusion.

    Science.gov (United States)

    Caldwell, J H; Martin, G V; Link, J M; Krohn, K A; Bassingthwaighte, J B

    1990-01-01

    Imaging 123I-labeled iodophenylpentadecanoic acid (IPPA) uptake and clearance from the myocardium following exercise has been advocated as a means of detecting myocardial ischemia because fatty acid deposition is enhanced and clearance prolonged in regions of low flow. However, normal regional myocardial blood flows are markedly heterogeneous, and it is not known how this heterogeneity affects regional metabolism or substrate uptake and thus image interpretation. In five instrumented dogs running at near maximal workload on a treadmill, 131I-labeled IPPA and 15-micron 46Sc microspheres were injected into the left atrium after 30 sec of circumflex coronary artery occlusion. Microsphere and IPPA activity were determined in 250 mapped pieces of myocardium of approximately 400 mg. Myocardial blood flows (from microspheres) ranged from 0.05 to 7.6 ml/min/g. Deposition of IPPA was proportional to regional flows (r = 0.83) with an average retention of 25%. The mean endocardial-epicardial ratio for IPPA (0.90 +/- 0.43) was similar to that for microspheres (0.94 +/- 0.47; p = 0.08). Thus, initial IPPA deposition during treadmill exercise increases in proportion to regional myocardial blood flow over a range of flows from very low to five times normal.

  4. Adenosine stress and exercise 99Tcm-MIBI myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Xu Shoulin; Feng Xuefeng

    2008-01-01

    Objective: The aim of this study was to evaluate the clinical value of adenosine stress or exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina. Methods: Eighty-seven hospitalized patients with unstable angina [54 men and 33 women, aged of (56.5±12.5) years] underwent adenosine stress or exercise myocardial perfusion imaging and coronary angiography. Patients were followed up. Results: Fifty-seven patients had abnormal myocardial perfusion imaging and significant coronary artery stenosis. Ten patients had abnormal myocardial perfusion imaging but normal coronary angiography. Eight patients had normal myocardial perfusion imaging but significant coronary artery stenosis. Twelve patients had normal myocardial perfusion imaging and normal coronary angiography. Patients with abnormal myocardial perfusion imaging had worse prognosis. There was relationship between cardiac events and the extent and severity of myocardial ischemia. Conclusion: Adenosine stress and exercise myocardial perfusion imaging is of important clinical value in the diagnosis and risk stratification of patients with unstable angina. (authors)

  5. Effect of thrombolytic therapy on exercise response during early recovery from acute myocardial infarction

    DEFF Research Database (Denmark)

    Svendsen, J H; Madsen, J K; Saunamäki, K I

    1992-01-01

    Several studies have shown that infarct size is reduced following thrombolytic treatment in patients with acute myocardial infarction. Exercise test variables, such as an impaired heart rate response during exercise, are known to be related to left ventricular function and patient prognosis follo...

  6. A comparative study between TL-201 SPECT myocardial perfusion scintigraphy and dobutamine stress echocardiography in the detection of coronary artery disease at the Philippine Heart Center

    International Nuclear Information System (INIS)

    Ogbac, R.V.; Martinez, A.O.; Obaldo, J.M.; Monzon, O.P.; Torres, J.F.; Rondilla, L.W.S.; Yap, J.S.; Flores, V.B.; Santos, R.J.; Jara, R.D.

    1996-01-01

    Although thallium-201 SPECT myocardial perfusion scintigraphy (MPS) has shown considerable accuracy for the detection of coronary artery disease (CAD), dobutamine stress echocardiography (DSE), a relatively new method for the detection of CAD had been recently utilized at the Philippine Heart Center. To assess its diagnostic worth versus that of thallium-201 spect myocardial scintigraphy (MPS), we studied 18 patients who underwent both procedures. Coronary angiography (CA) was used as the gold standard. MPS was performed with maximal treadmill exercise or with dipyridamole (0.568 mg/kg over 4 minutes) and Tl-201 was injected at peak stress. DSE was performed by infusing dobutamine at an increment of 5 μg/kg/min up to a maximum of 40. Atropine (0.01%) was added when 85% of maximum predicted heart rate is not achieved. Significant stenosis (>70%) was found in 16 out of 18 patients by CA. The sensitivity for the presence of CAD was 88% (14/16) and 69% (11/16) for MPS and DSE respectively. Specificity was 100% (2/2) for both. PPV was 100% for both while NPV was 50% and 29% for MPS and DSE respectively. Diagnostic accuracies were 89% and 72% for MPS and DSE respectively (P>0.05). Sensitivity for detecting left anterior descending artery (LAD) lesion was 71% 64% for MPS and DSE respectively; specificity was 75% and 100% respectively. For the left circumplex artery (LCX) lesion, both MPS and DSE had a sensitivity of 62% and specificity of 60%. Likewise for the right coronary artery (RCA) lesion, both had a sensitivity of 66% and specificity of 50%. Diagnostic accuracies were equal for both tests at 72% for LAD; 61% for LCX; and 61% for RCA. Kappa tests for association shows ρ values of >0.05 for overall and individual CAD detection suggesting no significant difference between MPS and DSE. Although there is a trend showing better detection of CAD with MPS, this particular study shows that both tests are comparable with regards to detection of the presence of CAD and of

  7. Effect of flaxseed supplementation and exercise training on lipid profile, oxidative stress and inflammation in rats with myocardial ischemia.

    Science.gov (United States)

    Nounou, Howaida A; Deif, Maha M; Shalaby, Manal A

    2012-10-05

    Flaxseed has recently gained attention in the area of cardiovascular disease primarily because of its rich contents of α-linolenic acid (ALA), lignans, and fiber. Although the benefits of exercise on any single risk factor are unquestionable, the effect of exercise on overall cardiovascular risk, when combined with other lifestyle modifications such as proper nutrition, can be dramatic.This study was carried out to evaluate the protective role of flaxseed and exercise on cardiac markers, lipids profile and inflammatory markers in isoproterenol (ISO)-induced myocardial ischemia in rats. The research was conducted on 40 male albino rats, divided into 4 groups (n=10): group I served as control, group II has acute myocardial ischemia induced by isoproterenol, groups III and IV have acute myocardial ischemia induced by isoproterenol pretreated with flaxseed supplementation orally for 6 weeks, additionally group IV practiced muscular exercise through swimming. Alterations of lipid profile, cardiac and inflammatory markers (Il-1β, PTX 3 and TNF- α) were observed in myocardial ischemia group. Flaxseed supplementation combined with exercise training showed significant increase of HDL and PON 1, on the other hand cardiac troponin, Il- 1β and TNF- α levels significantly decreased as compared to myocardial ischemic group. Receiver Operating Characteristics (ROC) analysis of cTnI, PTX 3, Il-1β and TNF- α revealed a satisfactory level of sensitivity and specificity. Regular exercise enhances the improvement in plasma lipoprotein levels and cardiovascular protection that results from flaxseed supplementation by mitigating the pathophysiology of atherosclerosis. Elevation of HDL, the antioxidant PON 1 and the cardioprotective marker PTX 3 emphasizes the protective effects of flaxseed and muscular exercise mutually against the harmful effects of acute myocardial ischemia.

  8. Effect of flaxseed supplementation and exercise training on lipid profile, oxidative stress and inflammation in rats with myocardial ischemia

    Directory of Open Access Journals (Sweden)

    Nounou Howaida A

    2012-10-01

    Full Text Available Abstract Background Flaxseed has recently gained attention in the area of cardiovascular disease primarily because of its rich contents of α-linolenic acid (ALA, lignans, and fiber. Although the benefits of exercise on any single risk factor are unquestionable, the effect of exercise on overall cardiovascular risk, when combined with other lifestyle modifications such as proper nutrition, can be dramatic. This study was carried out to evaluate the protective role of flaxseed and exercise on cardiac markers, lipids profile and inflammatory markers in isoproterenol (ISO-induced myocardial ischemia in rats. Methods The research was conducted on 40 male albino rats, divided into 4 groups (n=10: group I served as control, group II has acute myocardial ischemia induced by isoproterenol, groups III and IV have acute myocardial ischemia induced by isoproterenol pretreated with flaxseed supplementation orally for 6 weeks, additionally group IV practiced muscular exercise through swimming. Results Alterations of lipid profile, cardiac and inflammatory markers (Il-1β, PTX 3 and TNF- α were observed in myocardial ischemia group. Flaxseed supplementation combined with exercise training showed significant increase of HDL and PON 1, on the other hand cardiac troponin, Il- 1β and TNF- α levels significantly decreased as compared to myocardial ischemic group. Receiver Operating Characteristics (ROC analysis of cTnI, PTX 3, Il-1β and TNF- α revealed a satisfactory level of sensitivity and specificity. Conclusion Regular exercise enhances the improvement in plasma lipoprotein levels and cardiovascular protection that results from flaxseed supplementation by mitigating the pathophysiology of atherosclerosis. Elevation of HDL, the antioxidant PON 1 and the cardioprotective marker PTX 3 emphasizes the protective effects of flaxseed and muscular exercise mutually against the harmful effects of acute myocardial ischemia.

  9. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve

    Science.gov (United States)

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-01-01

    Abstract The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD). We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC. FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = −0.584 and r = −0.568, respectively, both P system can predict FFR at an optimal cut-off of <0.80, and we propose a novel application of CT-AC to MPI-IQ-SPECT for predicting clinically significant and insignificant FFR even in nonobese patients. PMID:29390486

  10. The Role of Routine Whole Volume SPECT Reconstruction in Comparison to Cine Raw Data in the Detection of Extracardiac Uptake on Myocardial Perfusion Scans

    International Nuclear Information System (INIS)

    Maharaj, M.; Korowlay, N.A.

    2011-01-01

    The objective of this study was to determine the role of routine whole volume reconstructed single-photon emission tomography (rSPECT) compared to cine raw data to detect extracardiac uptake of Sestamibi (MIBI). In a retrospective study, the myocardial perfusion studies of 426 patients were inspected separately for extracardiac uptake on cine raw data and rSPECT. The acquisition parameters for all the images were done according to departmental protocol. The whole volume SPECT data was selected and processed by HOSEM iterative reconstruction using the HERMES computer software system. The images were assessed by two observers, a student in training and a senior consultant nuclear medicine physician. The overall mean age and standard deviation of the 426 patients at the time of the study was 60 ± 12 years. Statistical analysis was performed using the Kappa and McNemars tests. The clinical significance of the extracardiac uptake was evaluated using hospital folders and /or laboratory results after viewing images. rSPECT detected 25 patients (5.9%) and cine raw data identified 18 patients (4.2%) with extracardiac uptake. All the areas of extracardiac uptake noted on cine raw data were seen on the rSPECT images. Only 21 of the 25 patients had complete 5-year clinical follow-up. The value of the clinical significance of the extracardiac uptake was limited due to the study being retrospective. The proportion of positives identified by rSPECT was significantly larger than those identified by cine raw data (P = 0.0082). Although our study demonstrates that rSPECT is more sensitive than cine raw data in detecting extracardiac uptake, it also shows that there is no benefit in routine whole volume rSPECT in daily clinical practice

  11. Determination of improved myocardial perfusion after aortocoronary bypass surgery by exercise 81Rb scintigraphy

    International Nuclear Information System (INIS)

    Lurie, A.J.; Salel, A.F.; Berman, D.S.; DeNardo, G.L.; Hurley, E.J.; Mason, D.T.

    1976-01-01

    Practical and noninvasive means are needed for evaluating efficacy of coronary bypass surgery (CBS) in improving blood flow (CBF) to ischemic myocardium in coronary patients. Revascularization was assessed in 15 patients by pre- and post-CBS rest and exercise rubidium-81 myocardial images with a scintillation camera equipped with pinhole collimator and high-energy shield. Ischemic areas were detected by decreased 81 Rb activity after exercise compared to rest. Before CBS all patients had exercise angina (EA), positive treadmill ECG (TECG), and abnormal exercise 81 Rb scans. After CBS all 15 patients had increased physical activity before angina or completion of treadmill exercise with increased heart rate-blood pressure product (HRBP) (+63 +/- 3.2 x 10(2) bpm - mm Hg) in 14 of 15 patients indicating increased CBF; four had positive TECG, and five had EA. The increased HRBP in 14 patients was associated with improved post-CBS exercise 81 Rb scans: six had normal patterns while nine were improved with less ischemic patterns. Further, lack of angina and increased exercise tolerance correlated closely with increased 81 Rb myocardial perfusion. Thus pre- and postoperative rest and exercise 81 Rb scintigraphy gives an accurate, noninvasive, objective approach for evaluation of CBF following CBS and demonstrates the usefulness of this revascularization procedure in coronary patients

  12. Brain SPECT using dipyridamole for evaluation of vascular reserve

    International Nuclear Information System (INIS)

    Kim, Su Zy; Park, Chan Hee; Yoon, Soo Hwan; Pai, Moon Sun; Yoon, Suk Nam; Cho, Kyung Kee

    1997-01-01

    Baseline and stress brain SPECT studies using CO 2 inhalation, acetazolamide (Diamox R ) and adenosine administrations have been used in the evaluation of cerebral vascular reserve. Recently dipyridamole (Persantine R ) which is one of the pharmacologic myocardial perfusion SPECT agents as a potent vasodilator is suggested as another cerebral vasodilator. IV Diamox R is not available in Korea. Therefore, the purpose of our study was to evaluate dipyridamole in stress brain SPECT in patients with Moya Moya disease. Eight patients with angiographically proven Moya Moya disease were studied. Their ages ranged from 7 to 62 year old. There were 4 males and 4 females. Each patient had a baseline and persantine brain SPECT studies with 1 to 3 days' interval. Dipyridamole was given intravenously at a dose of 0.56 mg/kg over 4 minutes while watching vital signs such as blood pressure, heart rate, and electrocardiogram. Three minutes after the completion of the infusion, 99mTc-ECD (0.2 mCi/Ib body weight) was injected. Brain SPECT was performed 30 minutes later using a tripple head gamma camera equipped with LEHR collimators. A total of 128 projections with an acquisition time of 30 second per projection was obtained and reconstructed by filtered back projections without attenuation correction. The difference between the baseline and persantine studies was analysed by visual and semiquantitavely. During the infusion of persantine, heart rate, blood pressure and side effects such as headache, chest discomfort were similar to the persantine myocardial SPECT studies. Five of eight patients showed a significant decrease in rCBF on persantine brain SPECT in comparison to the baseline study. The remaining three revealed no significant change in rCBF. Our study suggests that the dipyridamole stress brain SPECT is feasible and useful in assessing cerebral blood flow reserve. However we need to evaluate more number of patients in the future

  13. Normal myocardial perfusion imaging in the presence of significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Tian Yueqin; He Zuoxiang; Fang Wei; Yang Minfu; Shen Rui

    2007-01-01

    Objective: The aim of this study was to investigate the factors which might result in normal myocardial perfusion imaging in the presence of significant coronary artery stenosis. Methods: One hundred and thirty-three patients [mean age of (59±10) years, 98 men, 35 women] who underwent coronary angiography and myocardial perfusion SPECT were retrospectively analyzed. Results: Forty-six (35%) patients performed adequate bicycle exercise testing and achieved more than 85% of their predicted maximal heart rates; while 87 (65%) patients did not. Eighty-four (63%) patients had single coronary stenosis, 31(23%) two-vessel and 17(13%) three-vessel diseases. The difference in stenosis severity among the vessels in 13 (76%) cases with three-vessel diseases was not more than 20%. There were totally 202 coronary artery stenosis: 93 (46%) in left anterior descending coronary artery (LAD), 52 (26%) left circumflex coronary artery (LCX), 52(26% ) right coronary artery (RCA) and 5 (2%) left main coronary artery (LM) disease. Eighty-six(43%) vessels had 50%-70% stenosis, 100 (49%) >70%-90% and 16(8% )more than 90%. Conclusion: Normal myocardial perfusion imaging with significant coronary artery stenosis can probably due to inadequate exercise, single vessel disease and mild to moderate stenotic lesion. (authors)

  14. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    Science.gov (United States)

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS SSS >9 were compared to patients with SSS SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  15. Prognostic Usefulness of Low Ischemic Risk SPECT in non-ST Segment Elevation Acute Coronary Syndromes

    International Nuclear Information System (INIS)

    Castillo Costa, Yanina; Mauro, Victor; Perez, Roberto; Charask, Adrian; Fairman, Enrique; Gomez Santamaria, Hector; Goral, Jorge; Barrero, Carlos

    2009-01-01

    Background: Myocardial perfusion imaging tests are used for the clinical assessment of patients hospitalized with non-ST segment elevation acute coronary syndromes (NSTACS) who have favorable in-hospital outcomes with medical therapy. However, the prognostic relevance of a .low ischemic risk. (LR) single photon emission computed tomography (SPECT) in patients with NSTACS managed with a conservative approach is uncertain, as most of the information derives from patients with chronic coronary artery disease. Objectives: 1) To analyze the outcomes of patients with NSTACS and LR SPECT at discharge, 2) to compare the results of a normal SPECT with transient perfusion defects (TPDs), permanent perfusion defects (PPDs) or combined defects (CDs), and 3) to determine the additional value of SPECT to classic risk variables. Material and Methods: Patients admitted to the CCU with a NSTACS were included. Follow-up was continued during 12 months. Definitions: Clinical risk based on TIMI risk score. LR SPECT (under exercise or pharmacological stress): TPDs ≤ 3/17 segments, PPDs ≤ 3/17 segments, CPDs: TPDs + PPDs and normal: absence of defects. Clinical events (CEs): death/infarction or rehospitalization due to angina. Results: A total of 137 patients were included (median age 59 years, 60% were men). A low TIMI risk score was present in 54% of patients and 46% presented a moderate risk. CE: 5.8%. The incidence of clinical events related to perfusion defects was as follows: normal: 2.1%, TPD: 4.5%, PPD: 5.9% and CPD: 25% (p [es

  16. Four-dimensional MAP-RBI-EM image reconstruction method with a 4D motion prior for 4D gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taek-Soo; Tsui, Benjamin M.W. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Radiology; Gullberg, Grant T. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2011-07-01

    We evaluated and proposed here a 4D maximum a posteriori rescaled-block iterative (MAP-RBI)-EM image reconstruction method with a motion prior to improve the accuracy of 4D gated myocardial perfusion (GMP) SPECT images. We hypothesized that a 4D motion prior which resembles the global motion of the true 4D motion of the heart will improve the accuracy of the reconstructed images with regional myocardial motion defect. Normal heart model in the 4D XCAT (eXtended CArdiac-Torso) phantom is used as the prior in the 4D MAP-RBI-EM algorithm where a Gaussian-shaped distribution is used as the derivative of potential function (DPF) that determines the smoothing strength and range of the prior in the algorithm. The mean and width of the DPF equal to the expected difference between the reconstructed image and the motion prior, and smoothing range, respectively. To evaluate the algorithm, we used simulated projection data from a typical clinical {sup 99m}Tc Sestamibi GMP SPECT study using the 4D XCAT phantom. The noise-free projection data were generated using an analytical projector that included the effects of attenuation, collimator-detector response and scatter (ADS) and Poisson noise was added to generated noisy projection data. The projection datasets were reconstructed using the modified 4D MAP-RBI-EM with various iterations, prior weights, and sigma values as well as with ADS correction. The results showed that the 4D reconstructed image estimates looked more like the motion prior with sharper edges as the weight of prior increased. It also demonstrated that edge preservation of the myocardium in the GMP SPECT images could be controlled by a proper motion prior. The Gaussian-shaped DPF allowed stronger and weaker smoothing force for smaller and larger difference of neighboring voxel values, respectively, depending on its parameter values. We concluded the 4D MAP-RBI-EM algorithm with the general motion prior can be used to provide 4D GMP SPECT images with improved

  17. Myocardial perfusion scintigraphy 2006 in Germany. Results of the query and current status

    International Nuclear Information System (INIS)

    Lindner, O.; Burchert, W.; Bengel, F.M.; Zimmermann, R.; Dahl, J. vom; Schaefer, W.; Schober, O.; Kluge, R.; Schaefers, M.

    2008-01-01

    Aim: this second survey was to deliver further information on myocardial perfusion scintigraphy (MPS) in Germany in 2006. Method: 351 questionnaires were evaluated: 207 private practices (PP), 117 hospitals (HO), 27 from university hospitals (UH). Results: MPS of 106 331 patients were reported, 85% were investigated with 99m Tc-perfusion tracers. 74% [2005 = 72%] were performed in PP, 17% [2005 = 15%] in HO and 9% [2005 = 13%] in UH. PP, which participated in 2005 and 2006, demonstrated an increase by 3,9% (HO 0%, UH -13,0%). The type of stress was pharmacological in 27% [2005 = 22%]; 54% adenosine (of these 29% with exercise), 37% dipyridamole (of these 56% with exercise), and 9% dobutamine. Gated SPECT was performed in 42% [2005 = 36%] of all rest- and in 39% [2005 32%] of all stress MPS. An attenuation correction was used by 69 [2005 = 78] institutions. 40% of all MPS were performed in patients suspected to have CAD. 24% of all institutions reported changes in the use of MPS by competing methods. Conclusion: there is a small increase of MPS between 2005 and 2006 despite competing methods. Gated SPECT has experienced more acceptance. Suspicion of CAD is an important indication of MPS. In order to tap the full potential of MPS a gated SPECT should be performed routinely. (orig.)

  18. Effect of scatter correction on quantification of myocardial SPECT and application to dual-energy acquisition using triple-energy window method

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Matsudaira, Masamichi; Yamada, Masato; Taki, Junichi; Tonami, Norihisa; Hisada, Kinichi

    1995-01-01

    Triple-energy window (TEW) method is a simple and practical approach for correcting Compton scatter in single-photon emission tracer studies. The fraction of scatter correction, with a point source or 30 ml-syringe placed under the camera, was measured by the TEW method. The scatter fraction was 55% for 201 Tl, 29% for 99m Tc and 57% for 123 I. Composite energy spectra were generated and separated by the TEW method. Combination of 99m Tc and 201 Tl was well separated, and 201 Tl and 123 I were separated within an error of 10%; whereas asymmetric photopeak energy window was necessary for separating 123 I and 99m Tc. By applying this method to myocardial SPECT study, the effect of scatter elimination was investigated in each myocardial wall by polar map and profile curve analysis. The effect of scatter was higher in the septum and the inferior wall. The count ratio relative to the anterior wall including scatter was 9% higher in 123 I, 7-8% higher in 99m Tc and 6% higher in 201 Tl. Apparent count loss after scatter correction was 30% for 123 I, 13% for 99m Tc and 38% for 201 Tl. Image contrast, as defined myocardium-to-left ventricular cavity count ratio, improved by scatter correction. Since the influence of Compton scatter was significant in cardiac planar and SPECT studies; the degree of scatter fraction should be kept in mind both in quantification and visual interpretation. (author)

  19. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual 201 Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of the coronary reserves

    International Nuclear Information System (INIS)

    Mendoza V, R.

    2004-01-01

    The objective of this work was to determine if the images of SPECT 201 TI in rest of 15 minutes, 24 late hours and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of 201 TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT 201 TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of 201 TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  20. Exercise-induced ST-T changes and severity of myocardial ischemia in single-vessel coronary artery disease

    International Nuclear Information System (INIS)

    Shimonagata, Tsuyoshi; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Takamiya, Makoto; Sumiyoshi, Tetsuya; Saito, Muneyasu.

    1986-01-01

    The purpose of this study was to evaluate how exercise-induced ST-T changes reflect the severity of myocardial ischemia in 66 patients with singlevessel disease (SVD) who underwent stress thallium scans. Quantitative assessment of myocardial ischemia was performed with thallium ischemic score (TIS) derived from circumferential profile analysis. Circumferential profiles of the initial and 4 hr redistribution myocardial image were generated for each of three views (ANT, LAO 45, LAO 70) and TIS was obtained as the average of the area between the initial and 4 hr redistribution profile for each view. In 66 patients with SVD, TIS were compared with coronary angiographic findings. TIS was correlated well with the severity of coronary artery stenosis. In addition, TIS was also correlated well with lung thallium uptake in 46 LAD disease. Therefore, these data proved that TIS was useful for the evaluation of the severity of myocardial ischemia. In 46 LAD disease, TIS, being as the indicator of the severity of myocardial ischemia, was compared precisely with results of stress electrocardiograms to evaluate how exercise-induced ST-T changes reflect the severity of myocardial ischemia. Patients with negative U wave had the highest mean TIS and those with horizontal or down sloping ST depression of 1.0 mm or more had higher mean TIS than those with slow upsloping ST depression of 1.5 mm or more, but there were no significant differences between these groups and those without ST-T change and the mean TIS was not different significantly between V 2-6 ST depression group and V 2-6 , II, III, a V F ST depression group. In conclusion, these results indicated that exercise-induced ST-T changes reflect the severity of myocardial ischemia in some degree but also has a limitation in evaluation of the severity of myocardial ischemia. (author)

  1. Role of stress myocardial perfusion SPECT scan in detection and management of coronary artery disease: Nairobi experience

    International Nuclear Information System (INIS)

    Makhdomi, K.B.; Warshow, M.M.; Patel, P.K.J.; Shah, D.; Githegi, D.R.M.

    2002-01-01

    Aim: Stress myocardial perfusion scans have acquired a significant role in the detection and management of Coronary Artery Disease. However, this mode of investigation has only recently been available in Nairobi, and this is the first such study from East Africa. We undertook a comparison of our results with that in the literature, to see whether they conformed to it. Materials and Methods: We performed a review of our initial 82 evaluable studies. The scans were performed with 99mTc-Tetrofosmin, using the single day stress-rest protocol with SPECT acquisitions. We carried out a correlation of our scan findings with angiographic data (where available), and clinical follow-up. The clinical end points where furnished by the referring physicians. We focused on myocardial infarction, need for re-vascularisation, and death. The mean clinical follow-up was 21.8 months (range of 12 months to 39 months). Results: Eighty (98%) of the studies revealed concordance with angiographic findings and/or were predictive of clinical outcome. Two studies were discordant, and will be discussed. The results are comparable with those in the literature. Conclusion: It is concluded that stress myocardial perfusion studies, done at our Centre, had a good predictive value, with regards to the presence and severity of disease, and correlated with the clinical outcome data

  2. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-{beta}-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Katsuya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-10-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using {sup 123}I-{beta}-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and {sup 201}thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p<0.042). However, when Tl defect score was larger than BMIPP defect score, an increase in Tl defect score was slight. A significant negative correlation was found between the sum of the BMIPP and Tl defect scores and the left ventricular ejection fraction (LVEF) (r=0.66, p<0.0001). According to the histo-pathological study of two autopsied hearts, severe myocardial fibrosis was seen in segments with fixed perfusion defect. In addition, the mismatched segments of BMIPP defect score > Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  3. Clinical usefulness of hyperventilation-loaded SPECT in coronary artery disease

    International Nuclear Information System (INIS)

    Taya, Makoto

    1994-01-01

    The purpose of this study was twofold: (1) to assess the clinical usefulness of hyperventilation-loaded Tl-201 myocardial single photon emission computed tomography (HV-SPECT) in detecting coronary spasm; and (2) to correlate coronary spasm with ischemic heart diseases. A total of 138 patients were examined. They were divided into Group 1 of a total of 69 patients with chest pain at rest, consisting of 25 with vasospastic angina and 44 with atypical chest pain; Group 2 of 37 patients with angina pectoris; and Group 3 of 32 patients with myocardial infarction. In Group I, HV-SPECT was positive in 96% (24/25) for vasospastic angina and 50% (22/44) for atypical angina pectoris. When thallium defect scores 2 or more were interpreted as a decreased thallium uptake, Tl-201 HV-SPECT had a sensitivity of 72%, a specificity of 93%, and an accuracy of 85.6% in diagnosing vasospastic angina. In Group 2, HV-SPECT showed a significantly higher positive rate in patients with resting angina pectoris than those with effort angina pectoris (69% vs 22%). In Group 3, HV-SPECT was a positive rate of 53%. When Nifedipine was administered, the positive cases turned to be negative in 47%. HV-SPECT proved to be useful as a noninvasive method for diagnosing coronary spasm. Coronary spasm was suggested to be present in ischemic heart disease other than vasospastic angina and atypical chest pain. (N.K.)

  4. Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium-99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Oguzhan, A.; Kisacik, H.L.; Ozdemir, K.

    1997-01-01

    To compare the value of exercise electrocardiography with dobutamine stress echocardiography and exercise technetium-99m isonitrile single-photon emission computed tomography for coronary artery disease, 70 patients with either suspected or proven coronary artery disease underwent dobutamine stress echocardiography, exercise technetium-99m isonitrile single-photon emission computed tomography (mibi-SPECT) and treadmill exercise electrocardiography (ECG). Dobutamine echocardiography and exercise mibi-SPECT revealed a higher overall sensitivity than exercise testing (90 vs 57%, p 0.05; 90 and 62% p<0.05, respectively) but the difference between dobutamine stress echocardiography and exercise mibi-SPECT was not statistically significant. Diagnostic accuracy of dobutamine stress echocardiography and exercise mibi-SPECT was higher than that of exercise testing (90 vs 59%, p<0.001; 89 vs 59%, p<0.001, respectively). Dobutamine stress echocardiography and exercise mibi-SPECT have superiority over exercise testing in the diagnosis of coronary artery disease and dobutamine stress echocardiography is an alternative for exercise mibi-SPECT. (author)

  5. Mismatched regional myocardial uptake between [sup 123]I-BMIPP and [sup 201]Tl SPECT; Comparison between hypertrophic myocardium and dilated myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Ejima, Junichi; Tsuda, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-07-01

    The distribution of a new myocardial fatty acid metabolic agent [sup 123]I-BMIPP was compared in 6 each patients with hypertrophic myocardium (4 cases of hypertensive heart disease and 2 of hypertrophic cardiomyopathy) and dilated myocardium (4 of dilated type of valvular heart disease and 2 of dilated cardiomyopathy) with that of [sup 201]Tl. Mismatched regional myocardial uptake between [sup 123]I-BMIPP and [sup 201]Tl SPECT was observed in all of the hypertrophic myocardium, however no but one in the dilated myocardium. Relative increase or decrease in regional BMIPP from the images of 20 min and to those of 4 h was observed in 3 cases of the hypertrophic myocardium. FDG-PET was performed in 2 cases of the hypertrophic myocardium. The distribution of FDG was different from neither those of BMIPP nor Tl in a hypertrophic cardiomyopathy case with the reserved distribution of BMIPP and Tl. Although more investigations are necessary, we concluded that [sup 123]I-BMIPP is a promising radiopharmaceutical for evaluating myocardial fatty acid metabolism in hypertrophic myocardium. (author).

  6. Validation of Left Ventricular Ejection Fraction with the IQ•SPECT System in Small-Heart Patients.

    Science.gov (United States)

    Yoneyama, Hiroto; Shibutani, Takayuki; Konishi, Takahiro; Mizutani, Asuka; Hashimoto, Ryosuke; Onoguchi, Masahisa; Okuda, Koichi; Matsuo, Shinro; Nakajima, Kenichi; Kinuya, Seigo

    2017-09-01

    The IQ•SPECT system, which is equipped with multifocal collimators ( SMART ZOOM) and uses ordered-subset conjugate gradient minimization as the reconstruction algorithm, reduces the acquisition time of myocardial perfusion imaging compared with conventional SPECT systems equipped with low-energy high-resolution collimators. We compared the IQ•SPECT system with a conventional SPECT system for estimating left ventricular ejection fraction (LVEF) in patients with a small heart (end-systolic volume IQ•SPECT. End-systolic volume, end-diastolic volume, and LVEF were calculated using quantitative gated SPECT (QGS) and cardioREPO software. We compared the LVEF from gated myocardial perfusion SPECT to that from echocardiographic measurements. Results: End-diastolic volume, end-systolic volume, and LVEF as obtained from conventional SPECT, IQ•SPECT, and echocardiography showed a good to excellent correlation regardless of whether they were calculated using QGS or using cardioREPO. Although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (65.4% ± 13.8% vs. 68.4% ± 15.2%) ( P = 0.0002), LVEF calculated using cardioREPO did not (69.5% ± 10.6% vs. 69.5% ± 11.0%). Likewise, although LVEF calculated using QGS significantly differed between conventional SPECT and IQ•SPECT (75.0 ± 9.6 vs. 79.5 ± 8.3) ( P = 0.0005), LVEF calculated using cardioREPO did not (72.3% ± 9.0% vs. 74.3% ± 8.3%). Conclusion: In small-heart patients, the difference in LVEF between IQ•SPECT and conventional SPECT was less when calculated using cardioREPO than when calculated using QGS. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  7. Rest/exercise thallium myocardial perfusion imaging: a new and rapid technique to evaluate coronary artery disease

    International Nuclear Information System (INIS)

    Segall, G.M.; Zipkin, R.E.; Stanford Univ., CA

    1993-01-01

    Twenty-six patients underwent conventional exercise/4-h redistribution thallium myocardial perfusion imaging as well as rest/exercise imaging on different days. For the rest/exercise study, patients were inmaged 10 min after receiving 1 mCi thallium at rest. The resting study was immediately followed by symptom-limited treadmill exercise. Patients were injected with 2 mCi thallium at peak exercise and imaged 10 min later. The entire rest/exercise study was completed in 2 h. There was a high degree of correlation between the two studies. Of the 130 segments analysed, 84 were normal and 46 were abnormal by exercise/redistribution imaging whereas 88 were normal and 42 were abnormal by rest/exercise imaging. Among the 14 patients who had coronary arteriography, both exercise/redistribution and rest/exercise imaging correctly identified 23/35 segments as abnormal (sensitivity [pi003] 66% and 34/35 segments as normal (specificity=97%). Furthermore, abnormal segments were more likely to be reversible on the rest/exercise study. The results suggest that the accuracy of rest/exercise thallium imaging is equal to conventional exercise/redistribution imaging in the evaluation of coronary artery disease. The significant time economy and possible improvement in assessing myocardial viability are important potential advantages of this new technique. (Author)

  8. Present assessment of myocardial viability by nuclear imaging.

    Science.gov (United States)

    Saha, G B; MacIntyre, W J; Brunken, R C; Go, R T; Raja, S; Wong, C O; Chen, E Q

    1996-10-01

    Prospective delineation of viable from nonviable myocardium in patients with coronary artery disease in an important factor in deciding whether a patient should be revascularized or treated medically. Two common techniques--single-photon emission computed tomography (SPECT) and positron-emission computed tomography (PET)--are used in nuclear medicine using various radiopharmaceuticals for the detection of myocardial viability in patients. Thallium-201 (201Tl) and technetium-99m (99mTc)-sestamibi are the common radiopharmaceuticals used in different protocols using SPECT, whereas fluoride-18 (18F)-fluorodeoxyglucose (FDG) and rubidium-82 (82Rb) are most widely used in PET. The SPECT protocols involve stress/redistribution, stress/redistribution/reinjection, and rest/redistribution imaging techniques. Many studies have compared the results of 201Tl and (99mTc)-sestamibi SPECT with those of FDG PET; in some studies, concordant results have been found between delayed thallium and FDG results, indicating that 201Tl, although considered a perfusion agent, shows myocardial viability. Discordant results in a number of studies have been found between sestamibi and FDG, suggesting that the efficacy of sestamibi as a viability marker has yet to be established. Radiolabeled fatty acids such as iodine-123 (123I)-para-iodophenylpentadecanoic acid and carbon-11 (11C)-palmitic acid have been used for the assessment of myocardial viability with limited success. 11C-labeled acetate is a good marker of oxidative metabolism in the heart and has been used to predict the reversibility of wall motion abnormalities. (18F)-FDG is considered the marker of choice for myocardial viability, although variable results are obtained under different physiological conditions. Detection of myocardial viability can be greatly improved by developing new equipment and radiopharmaceuticals of better quality.

  9. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    International Nuclear Information System (INIS)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung; Ho, Shung-Tai

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  10. Relation between myocardial damage and disease activity in patients with systemic lupus erythematosus by exercise {sup 201}Tl scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kuzumoto, Masayuki [Nara Medical Univ. (Japan)

    1997-08-01

    Myocardial damage in patients with systemic lupus erythematosus (SLE) was evaluated using exercise thallium-201 myocardial scintigraphy, and the relationship between myocardial damage and disease activity of SLE was examined. Twenty-seven patients (26 women and 1 man, mean age 43 years), in whom extramural coronary artery lesions were excluded by coronary angiogram or presumed to be excluded by exercise electrocardiogram, were enrolled in this study. The mean duration of disease and the mean duration of corticosteroid therapy in these patients were 94 and 77 months, respectively. Exercise thallium-201 scintigraphy was performed twice (mean interval, 30 months) to evaluate the progression of myocardial damage. Myocardial ischemia as an index of myocardial damage was evaluated by visual analysis and ischemic score (IS). The changes in myocardial ischemia were categorized into 3 groups: improved, unchanged or worsened. The disease activity of SLE was determined by the SLE Disease Activity Index (SLEDAI), and the changes in this index were classified into the same three categories, as evaluated every six months between the two scintigraphic examinations. Disease activity was significantly correlated with myocardial ischemia (p<0.05), and with myocardial ischemia as diagnosed by {Delta}IS (difference in ischemic score between the first and second thallium-201 scintigrams: p<0.005). But neither the duration of disease nor the duration of corticosteroid therapy was correlated with IS at the first scintigraphy. These results indicate that control of SLE disease activity may be critical in the treatment of myocardial damage resulting from vascular lesions, especially intramyocardial small-artery disease, in patients with SLE. (author)

  11. Clinical significance of normal exercise thallium-201 myocardial scintigraphy in subjects with abnormal exercise electrocardiographic findings

    International Nuclear Information System (INIS)

    Matsuo, Takeshi; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Chiba, Hiroshi; Mitani, Isao; Saito, Muneyasu; Sumiyoshi, Tetsuya

    1988-01-01

    The relationship between exercise thallium-201 scintigraphic findings and clinical features (chest pain, risk factors, resting electrocardiography, exercise electrocardiography and prognosis) was studied in the 234 patients with profound ST-segment depression (J 80 ≥ -2 mm) or negative U wave in exercise electrocardiography. We classified these cases into two groups by exercise thallium perfusion; (I) normal thallium-201 perfusion (n = 24), (II) abnormal thallium-201 perfusion (n = 210). The incidence of female in group I was larger than that in group II. In resting electrocardiography, left ventricular hypertrophy was found more frequent in group I. In exercise electrocardiography, most of ST-segment depression in group I revealed up-slope type and a rapid recovery to baseline. Group I had lower incidence of cardiac events (cardiac death, nonfatal myocardial infarction, percutaneous transluminal coronary angioplasty, coronary artery bypass grafting). In conclusion, normal thallium-201 perfusion in exercise thallium-201 scintigraphy was more useful indicator for prognosis, even if the patients had the findings of profound ST-segment depression or negative U wave in exercise electrocardiography. (author)

  12. Analysis of the relationship between myocardial viability and regional left ventricular wall motion

    International Nuclear Information System (INIS)

    Furutani, Yuhji; Ozaki, Masaharu; Yamamoto, Takeshi; Sato, Shinichi; Saiki, Atsushi; Kusukawa, Reizo

    1993-01-01

    Myocardial viability was determined by using postsystolic shortening (PSS) as an index, as obtained by cardiac blood pool scintigraphy with Tc-99m HSA. The findings were compared with those of thallium-201 myocardial SPECT. The study population was comparised of 41 patients with single blood vessel disease in the left anterior descending artery (34 with old myocardial infarction and 7 with effort angina pectoris). Left ventricular area was divided into 6 segments, and global and regional left ventricular blood volume curves were obtained. Delayed end-systole was the most common in the apex (41%), followed by the upper septum (37%) and lower septum (10%). PSS resulting from delayed end-systole was seen in 36 areas. PSS/end-diastolic volume (EDV) and PSS/systolic volume (SV) were obtained by adjusting end-diastolic and stroke counts, respectively. Thallium-201 myocardial SPECT images were divided into 5 segments to obtain defect score (DS) for visual Tl uptake. Both PSS/EDV and PSS/SV were greater in association with more delayed end-systole, greater DS, and lower reginal ejection fraction. Areas showing greater PSS were associated with less myocardial viability, as observed on Tl myocardial SPECT images. Thus, PSS seemed to reflect the degree of myocardial necrosis within the region of interest. (N.K.)

  13. Elevation of serum N-terminal pro-brain natriuretic peptide after exercise is an index of myocardial damage or a cytoprotective reflection?

    Science.gov (United States)

    Faviou, E; Zachari, A; Nounopoulos, C; Agrafiotis, E; Vourli, G; Dionyssiou-Asteriou, A

    2008-03-01

    Recent investigations have suggested the occurrence of transient cardiac dysfunction and reversible myocardial injury in healthy individuals after heavy exercise. Our purpose was to examine if the release of N-terminal pro-brain natriuretic peptide (NT-proBNP) after intense exercise in obviously healthy participants may have cytoprotective and growth-regulating effects or may result from myocardial dysfunction/damage with changes in cTnT as a marker for myocardial cell necrosis during exercise. In 43 highly-trained male athletes hypertrophy. A normal plasma concentration of NT-proBNP in consecutive routine check-up, before and after exercise, could minimize the possibility of cardiac dysfunction, whereas persistent elevated plasma concentrations warrant further cardiological evaluation.

  14. Kinetic parameter estimation from attenuated SPECT projection measurements

    International Nuclear Information System (INIS)

    Reutter, B.W.; Gullberg, G.T.

    1998-01-01

    Conventional analysis of dynamically acquired nuclear medicine data involves fitting kinetic models to time-activity curves generated from regions of interest defined on a temporal sequence of reconstructed images. However, images reconstructed from the inconsistent projections of a time-varying distribution of radiopharmaceutical acquired by a rotating SPECT system can contain artifacts that lead to biases in the estimated kinetic parameters. To overcome this problem the authors investigated the estimation of kinetic parameters directly from projection data by modeling the data acquisition process. To accomplish this it was necessary to parametrize the spatial and temporal distribution of the radiopharmaceutical within the SPECT field of view. In a simulated transverse slice, kinetic parameters were estimated for simple one compartment models for three myocardial regions of interest, as well as for the liver. Myocardial uptake and washout parameters estimated by conventional analysis of noiseless simulated data had biases ranging between 1--63%. Parameters estimated directly from the noiseless projection data were unbiased as expected, since the model used for fitting was faithful to the simulation. Predicted uncertainties (standard deviations) of the parameters obtained for 500,000 detected events ranged between 2--31% for the myocardial uptake parameters and 2--23% for the myocardial washout parameters

  15. Clinical studies on diabetic myocardial disease using exercise testing with myocardial scintigraphy and endomyocardial biopsy

    International Nuclear Information System (INIS)

    Genda, A.; Mizuno, S.; Nunoda, S.

    1986-01-01

    Nine diabetics without significant coronary stenosis participated in an exercise testing protocol with thallium-201 myocardial scintigraphy. Endomyocardial biopsy of right ventricle was also obtained. There were 4 patients with abnormal perfusion (positive group) and 5 patients with normal perfusion (negative group). All cases of the positive group were familial diabetics and there was only one case of dietary treatment, whereas in the negative group, there were only 2 cases of familial diabetics and 3 cases receiving dietary treatment. No statistical differences between the positive and negative groups were observed for the data of exercise performance and hemodynamic parameters in cardiac catheterization at rest. However, the mean ejection fraction in the positive group (62 +/- 13%) was significantly lower than in the negative group (77 +/- 4%). In both groups, the mean diameter of myocardial cells and the mean percent fibrosis of biopsy specimens showed significant increases compared with the control group. The mean percent fibrosis in the positive group (24.1 +/- 8.5%) compared with that in the negative group (16.5 +/- 5.9%) showed a tendency to increase. It is suggested that the abnormal perfusion of thallium-201 in the positive group indicates subclinically a pathological change of microcirculation caused by diabetes mellitus

  16. Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room

    Directory of Open Access Journals (Sweden)

    Ballinger Michelle R

    2008-01-01

    Full Text Available Abstract Treadmill exercise stress testing is an essential tool in the prevention, detection, and treatment of a broad spectrum of cardiovascular disease. After maximal exercise, cardiac images at peak stress are typically acquired using nuclear scintigraphy or echocardiography, both of which have inherent limitations. Although CMR offers superior image quality, the lack of MRI-compatible exercise and monitoring equipment has prevented the realization of treadmill exercise CMR. It is critical to commence imaging as quickly as possible after exercise to capture exercise-induced cardiac wall motion abnormalities. We modified a commercial treadmill such that it could be safely positioned inside the MRI room to minimize the distance between the treadmill and the scan table. We optimized the treadmill exercise CMR protocol in 20 healthy volunteers and successfully imaged cardiac function and myocardial perfusion at peak stress, followed by viability imaging at rest. Imaging commenced an average of 30 seconds after maximal exercise. Real-time cine of seven slices with no breath-hold and no ECG-gating was completed within 45 seconds of exercise, immediately followed by stress perfusion imaging of three short-axis slices which showed an average time to peak enhancement within 57 seconds of exercise. We observed a 3.1-fold increase in cardiac output and a myocardial perfusion reserve index of 1.9, which agree with reported values for healthy subjects at peak stress. This study successfully demonstrates in-room treadmill exercise CMR in healthy volunteers, but confirmation of feasibility in patients with heart disease is still needed.

  17. Assessment of non-typical worsening of myocardial perfusion in rest in comparison to stress in 99mTc-MIBI SPECT studies. Preliminary report

    International Nuclear Information System (INIS)

    Dabrowski, A.; Szumilak, B.; Wnuk, J.; Konieczna, S.; Teresinska, A.

    2002-01-01

    Worsening of regional rest perfusion in comparison to stress perfusion, observed in a few percentage of myocardial perfusion 99m Tc-MIBI SPECT studies, does not have an easy clinical interpretation. Also, no reports evaluating the relationship between worsening and technical SPECT study conditions are available. The goal of our study is: 1) to assess the reproducibility of this non-typical effect - by repeating the rest study on separate day after new MIBI injection; 2) to assess reproducibility of this effect in rest perfusion images performed at different time points after one MIBI injection; 3) to propose the most probable clinical explanation for this effect. Up to now, 20 patients (100 predicted altogether) with rest perfusion worsening in routine stress-rest 99m Tc-MIBI SPECT perfusion imaging were studied. The group was clinically in homogeneous (7 patients with suspected coronary artery disease (CAD), 4 patients with CAD and no myocardial infarction (MI), 8 patients after MI, and 1 patient with developmental anomaly). Within 14 days, rest study was repeated, with data acquisition performed at 1 h and 3 hrs after MIBI injection. Regional myocardial perfusion was evaluated qualitatively, in 17 segments of the LV and compared among stress and all the three rest (BAD-I, BAD-II, BAD-III) studies. In 175 segments there was perfusion worsening in at least one of the three rest studies. In the highest percentage of these segments (n=53, 30%, ), worsening was present in all rest studies. Among stress defects with perfusion worsening in BAD-I, the highest percentage (55%, ) presented worsening also in BAD-II (performed after separate injection of MIBI, but like in BAD-I also 1 h after injection), significantly lower percentage - persistent defect in BAD-II (25%, ), and some smaller percentage - transient defect in BAD-II (20%, ). In segments with perfusion worsening present in one of the rest studies, our preliminary results show: 1) the highest probability of

  18. Incremental value of regional wall motion analysis immediately after exercise for the detection of single-vessel coronary artery disease. Study by separate acquisition, dual-isotope ECG-gated single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yoda, Shunichi; Sato, Yuichi; Matsumoto, Naoya; Tani, Shigemasa; Takayama, Tadateru; Uchiyama, Takahisa; Saito, Satoshi

    2005-01-01

    Although the detection of wall motion abnormalities gives incremental value to myocardial perfusion single-photon emission computed tomography (SPECT) in the diagnosis of extensive coronary artery disease (CAD) and high-grade single-vessel CAD, whether or not it is useful in the diagnosis of mild, single-vessel CAD has not been studied previously. Separate acquisition, dual isotope electrocardiogram (ECG)-gated SPECT was performed in 97 patients with a low likelihood of CAD (Group 1) and 46 patients with single-vessel CAD (Group 2). Mild CAD was defined by stenosis of 50-75% (Group 2a, n=22) and moderate to severe CAD was defined by stenosis ≥76% (Group 2b, n=24). Myocardial perfusion and wall motion were graded by a 5 point-scale, 20-segment model. The sensitivity of myocardial perfusion alone was 50% for Group 2a, 83% for Group 2b and 67% for Group 2 as a whole. The overall specificity was 90%. When the wall motion analysis was combined, the sensitivity was increased to 82% in Group 2a and 92% in Group 2b. The ability to detect a wall motion abnormality immediately after exercise gives incremental diagnostic value to myocardial perfusion SPECT in the identification of mild, single-vessel CAD. (author)

  19. Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise

    International Nuclear Information System (INIS)

    Hashimoto, Jun; Kubo, Atsushi; Iwasaki, Ryuichiro; Iwanaga, Shiro; Mitamura, Hideo; Ogawa, Satoshi; Kosuda, Shigeru

    1999-01-01

    This study was designed to apply ECG-gating to stress myocardial perfusion single-photon emission tomography (SPET) for the evaluation of myocardial stunning after exercise. Technetium-99m sestamibi was selected as the perfusion agent and a rest/exercise 1-day protocol was employed. Fourteen patients without coronary stenosis and 33 patients with coronary stenosis were enrolled in the study. We carried out three data acquisitions with ECG-gating: a 15-min data acquisition starting 30 min after the rest injection (AC1), a 5-min acquisition starting 5 min after the stress injection (AC2) and a 15-min acquisition starting 20 min after the stress injection (AC3). Calculation of left ventricular ejection fraction (LVEF) values was performed by means of automatic determination of the endocardial surface for all gating intervals in the cardiac cycle. Measured global EF values in 14 patients without coronary stenosis were 52.3%±7.6% (AC1), 60.6%±8.9% (AC2) and 55.6%±5.6% (AC3), and those in 11 patients with severe ischaemia were 53.6%±8.0% (AC1), 45.6%±12.1% (AC2) and 49.7%±10.7%. The magnitude of the depression of post-stress LVEF relative to the rest LVEF correlated with the severity of ischaemia (r=0.594, P=0.002), and segments manifesting post-stress functional depression were associated with ischaemic segments showing reversible perfusion defects. Stress myocardial perfusion SPET with ECG-gating is a feasible method for the evaluation of myocardial stunning as well as exercise-induced ischaemia. (orig.)

  20. Myocardial functional responses do not contribute to maximal exercise performance in the heat.

    Science.gov (United States)

    Smith, Denise L; DeBlois, Jacob P; Wharton, Margaret; Rowland, Thomas

    2015-01-01

    Both the extent and means by which maximal oxygen uptake ([Formula: see text]) is depressed by elevated ambient temperature are uncertain. Particularly, information is currently unavailable regarding the possible influence of alterations in myocardial function on [Formula: see text] and performance during exercise in the heat. This study investigated the effects of environmental heat on [Formula: see text], peak work capacity, and myocardial function during a standard, progressive cycle test to exhaustion. Twelve euhydrated men (aged 20.7 ± 1.7 years) performed a maximal cycle test in an environmental chamber in both heat stress [35°C, 30% relative humidity (RH)] and temperate (20°C, 30% RH) conditions with measurement of standard gas exchange variables, core temperature, and echocardiographic measures of cardiac function. A small but statistically significant reduction of peak work capacity was observed in the heat stress versus temperate conditions (253 ± 30 and 259 ± 30 W, respectively, p = 0.02). Mean [Formula: see text] was not statistically different in the two conditions (p = 0.16) but values were 3.4% lower in the heat, and 9 of 12 participants demonstrated lower values in the heat stress trial. No differences in responses of heart rate, cardiac output, stroke volume, core temperature, hydration status, or myocardial systolic or diastolic function were observed between the two conditions, but perceived body temperature was higher in the heat. The small, negative impact of heat on exercise performance and [Formula: see text] could not be explained by disturbances in myocardial functional responses to exercise in young adult males.

  1. Paradoxical motion of interventricular septum on Tc-99m MIBI gated SPECT study

    International Nuclear Information System (INIS)

    Ergun, E.L.; Erbas, B.; Beylergil, V.; Demirturk, O.S.; Pasaoglu, I.

    2004-01-01

    After uncomplicated cardiac surgery, abnormal motion of the interventricular septum is frequently observed. The interventricular septum has often been found to display dyskinetic, or paradoxical motion by echocardiographic studies. This study was undertaken to describe instances of paradoxical motion of interventricular septum on Tc-99m MIBI gated SPECT studies in patients after coronary artery by pass graft surgery. Tc-99m MIBI gated SPECT in conjunction with stress myocardial perfusion SPECT was performed in 18 patients who had history of cardiac bypass graft surgery. Paradoxical motion of the interventricular septum was defined visually from Tc-99m MIBI gated SPECT. Perfusion of the interventricular septum was examined from myocardial perfusion images in the same study. Paradoxical motion of the interventricular septum was observed in 4 patients (22%). The interventricular septum was normally perfused in all patients. It was concluded that paradoxical motion of the interventricular septum in patients who had a history of cardiac by-pass graft surgery is not an uncommon finding and it can be observed with gated SPECT. The exact mechanism of this phenomenon is not well-known. A normal perfusion in interventricular wall helps to discriminate this situation from a real abnormality. (author)

  2. The predictive value of 201Tl rest-redistribution and 18F-fluorodeoxyglucose SPECT for wall motion recovery after recent reperfused myocardial infarction.

    Science.gov (United States)

    González, Patricio; Massardo, Teresa; Coll, Claudia; Humeres, Pamela; Sierralta, Paulina; Jofré, M Josefina; Yovanovich, Jorge; Aramburu, Ivonne; Brugère, Solange; Chamorro, Hernán

    2004-04-01

    201Tl and 18F-FDG are useful for acute myocardial infarction (MI) assessment. The goal of this study was to compare their predictive value for wall motion recovery in the culprit area after a recent reperfused MI using SPECT technique. Forty-one patients (mean age: 56 +/- 12 years) were included, 81% of them male; all were studied within 1-24 days post MI. They underwent angioplasty in 27 cases (12 primary); bypass grafting in 10 cases and successful thrombolysis in 4. SPECT 201Tl injected at rest and redistribution (R-R) and also 18F-FDG, were performed on different days. Processed tomograms were interpreted blinded to clinical or angiographic data. Segmental wall motion assessed with echocardiography at baseline was compared with the 3 month follow up. Sensitivity [Confidence Interval] for 201Tl R-R was 74.6% [60.5-84.5], for FDG it was 82.1% [70.8-90.4]; specificities were 73% [64.3-80.5] and 54.8% [45.6-63.7], respectively. 18F-FDG tended to be more sensitive than 201Tl R-R, but the latter was more specific (p < 0.0004). Both 201Tl RR and 18F-FDG presented high negative predictive value (p: ns). In recent MI, SPECT 201Tl R-R is a valuable and widely available technique for viability detection, with similar sensitivity and significant better specificity than SPECT 18F-FDG.

  3. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure

    Science.gov (United States)

    Shojaeifard, Maryam; Ghaedian, Tahereh; Yaghoobi, Nahid; Malek, Hadi; Firoozabadi, Hasan; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amin, Ahmad; Azizian, Nasrin; Rastgou, Feridoon

    2015-01-01

    Background: Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary artery diseases. However, considering the technical shortcomings of SPECT in the presence of perfusion defect, the accuracy of this method in heart failure patients is still controversial. Objectives: The aim of the present study was to compare the results from gated SPECT MPI with those from echocardiography in heart failure patients to compare echocardiographically-derived left ventricular dimension and function data to those from gated SPECT MPI in heart failure patients. Patients and Methods: Forty-one patients with severely reduced left ventricular systolic function (EF ≤ 35%) who were referred for gated SPECT MPI were prospectively enrolled. Quantification of EF, end-diastolic volume (EDV), and end-systolic volume (ESV) was performed by using quantitative gated spect (QGS) (QGS, version 0.4, May 2009) and emory cardiac toolbox (ECTb) (ECTb, revision 1.0, copyright 2007) software packages. EF, EDV, and ESV were also measured with two-dimensional echocardiography within 3 days after MPI. Results: A good correlation was found between echocardiographically-derived EF, EDV, and ESV and the values derived using QGS (r = 0.67, r = 0.78, and r = 0.80 for EF, EDV, and ESV, respectively; P echocardiography. ECTb-derived EDV was also significantly higher than the EDV measured with echocardiography and QGS. The highest correlation between echocardiography and gated SPECT MPI was found for mean values of ESV different. Conclusions: Gated SPECT MPI has a good correlation with echocardiography for the measurement of left ventricular EF, EDV, and ESV in patients with severe heart failure. However, the absolute values of these functional parameters from echocardiography and gated

  4. Effect of myocardial viability in the infarct area on regional left ventricular function

    International Nuclear Information System (INIS)

    Ishii, Toshihiko; Watanabe, Takeshi; Usui, Mikio; Nagai, Yoshikazu

    1990-01-01

    This study explored the relationship between global left ventricular ejection fraction (LVEF), regional LVEF of infarct myocardium, and the viability of the myocardium due to the development of collaterals in the infarct area. Each was evaluated by exercise thallium-201 myocardial SPECT, multigated blood pool scintigraphy and coronary angiography. A total of 68 patients with old anteroseptal myocardial infarction and 23 normal persons were studied. The patients were found to have septal defect on exercise thallium images. According to the appearance of redistribution (RD) on delayed images, the patients were classified as having positive RD (n=42, 62%) or negative RD (n=26, 38%). The global LVEF was compared with regional LVEF of the basal, middle and apical areas within septum, as calculated by multigated blood pool scintigraphy. There was no significant difference in global LVEF between the groups of positive and negative RD patients. However, regional LVEF of the basal and middle areas was significantly larger in the group of positive RD than the group of negative RD. Collaterals were significantly observed in the group of positive RD, as compared with the group of negative RD (53% vs 25%). It was more frequent in cases of higher degree of stenosis. In the group of negative RD, none of the patients had collaterals when coronary stenosis was 90% or less. Redistribution may reflect myocardial viability. Myocardial viability within the infarct area had favorable influences on the regional left ventricular function. Therefore, not only global but also regional left ventricular function is necessary for better understanding of pathophysiology of myocardial infarction.(N.K.)

  5. Left ventricular volume during supine exercise: importance of myocardial scar in patients with coronary heart disease

    International Nuclear Information System (INIS)

    Mann, D.L.; Scharf, J.; Ahnve, S.; Gilpin, E.

    1987-01-01

    Existing studies suggest that exercise-induced ischemia produces an increase in left ventricular end-diastolic volume; however, all of these studies have included patients with previous myocardial infarction. To test whether the end-diastolic volume response to exercise is related to the extent of myocardial scar, the results of gated radionuclide supine exercise tests performed on 130 subjects were reviewed. The patient group comprised 130 subjects were reviewed. The patient group comprised 130 men aged 35 to 65 years (mean +/- SD 52 +/- 5) with documented coronary heart disease. The extent of myocardial ischemia and scar formation was assessed by stress electrocardiography and thallium-201 scintigraphy. Patients were classified into three groups on the basis of left ventricular end-diastolic volume response at peak exercise: group 1 (n = 72) had an increase of end-diastolic volume greater than 10%, group 2 (n = 41) had a change in end-diastolic volume less than 10% and group 3 (n = 17) had a decrease in end-diastolic volume greater than 10% (n = 17). At rest there was no significant difference among groups in heart rate, systolic blood pressure, end-diastolic (EDVrest) or end-systolic volumes or ejection fraction (p greater than 0.05); however, at peak exercise the end-systolic volume response was significantly greater for group 1 (p less than 0.002)

  6. Is dipyridamole test equivalent to exercise testing for the performing of myocardial tomo-scintigraphy? preliminary results of a systematic comparative analysis in patients having documented episodes of myocardial ischemia

    International Nuclear Information System (INIS)

    David, N.; Quiri, N.; Hassan, N.; Arsena, T.; Py, M.; Olivier, P.; Karcher, G.; Bertrand, A.; Houriez, P.; Grentzinger, A.; Angioi, M.; Danchin, N.; Juilliere, Y.

    1997-01-01

    Dipyridamole test is generally used rather than exercise testing when myocardial tomo-scintigraphy (MTS) is performed with patients unable to perform a maximal exercise test. However, this choice has never been validated by a systematic comparative analysis of the results provided by these two stress techniques with patients having a documented myocardial ischemia. We have included 20 patients who had a known coronary artery disease, for whom exercise test was positive at the time of an exercise MTS-TI201 performed in our department and who underwent an additional MTS-TI201 after intravenous administration of 0,56 mg/kg of dipyridamole and low-level exercise testing (40 W). The extent of perfusion abnormalities, observed after dipyvirdamole, was not significantly different from that evidenced at exercise, even in the analysis restricted to the eight patients who had a sub-maximal test (<80 % of predicted maximal heart rate) at the time of exercise-MTS (% of left ventricle: 17 ± 13 vs 15 ± 8). By contrast, there were important individual variations: a difference in defect-extent (≥ 10 % of left ventricle) was observed between the two tests for 11 patients (55 %), the largest defect being that observed at exercise in six cases, and after dipyridamole in five cases. With patients having exercise myocardial ischemia, the MTS obtained after dipyridamole are frequently very different from those performed after exercise, and the criterion of a low maximal heart rate doses not imply an underestimation of the perfusion abnormalities observed at exercise. (authors)

  7. Myocardial infarction

    International Nuclear Information System (INIS)

    Ando, Jyoji; Yasuda, Hisakazu; Miyamoto, Atsushi; Kobayashi, Tsuyoshi

    1980-01-01

    sup(99m)Tc-pyrophosphate (PYP) scintigraphy and 201 Tl myocardial scintigraphy were utilized for the diagnoses of the presence, the region, and the extent of myocardial infarction. Exercise 201 Tl myocardial scintigrams and exercise radionuclide ventriculography were utilized for diagnosis of coronary artery lesions in angina pectoris. Radionuclide ventriculography was used to investigate effects of coronary artery lesions on cardiac function and hemodynamics. In order to select adequate treatments for myocardial infarction and estimate the prognosis, it was necessary to detect the presence, the region, and the extent of acute myocardial infarction and to investigate effects of partial infarction on hemodynamics by using radionuclide imaging. Exercise myocardial scintigraphy could be carried out noninvasively and repeatedly for diagnosis of coronal artery disease. Therefore, this method could be applied widely. It was possible to use this method as a screening test of coronary artery diseases for the diagnoses of asymptomatic patients who showed ST changes in ECG, the patients with cardiac neurosis and the patency after a reconstructive surgery of coronary artery. (Tsunoda, M.)

  8. Chronic aerobic exercise training alleviates myocardial fibrosis in aged rats through restoring bioavailability of hydrogen sulfide.

    Science.gov (United States)

    Ma, Ning; Liu, Hong-Mei; Xia, Ting; Liu, Jian-Dong; Wang, Xiao-Ze

    2018-06-02

    Age-related fibrosis is attenuated by aerobic exercise; however, little is known concerning the underlying molecular mechanism. To address this question, aged rats were given moderate-intensity exercise for 12 weeks. After exercise in aged rats, hydrogen sulfide (H2S) levels in plasma and heart increased 39.8% and 90.9%, respectively. Exercise upregulated expression of cystathionine γ-lyase (CSE) and 3-mercaptopyruvate sulfurtransferase (3-MST) in heart of aged rats. Furthermore, aged rats were given moderate-intensity exercise for 12 weeks or treated with NaHS (intraperitoneal injection of 0.1 ml/kg/day of 0.28 mol/l NaHS). After exercise in aged rats, Masson-trichrome staining area decreased 34.8% and myocardial hydroxyproline levels decreased 29.6%. Exercise downregulated expression of collagen-I and α-SMA in heart of aged rats. Exercise in aged rats reduced malondialdehyde levels in plasma and heart and 3-nitrotyrosine in heart. Exercise in aged rats reduced mRNA and protein expression of CHOP, GRP78, and XBP1. Exercise also reduced mRNA and protein expression of IL-6 and MCP-1 and suppressed activation of JNK in aging heart. Similar effects were demonstrated in aged rats treated with NaHS. Collectively, exercise restored bioavailability of hydrogen sulfide in the heart of aged rats, which partly explained the benefits of exercise against myocardial fibrosis of aged population.

  9. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji [Department of Cardiovascular Medicine, Gunma Prefectural Cardiovascular Center, Maebashi (Japan); Sato, Makito [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Tatebayashi Kosei Hospital, Department of Internal Medicine, Gunma (Japan); Sano, Hirokazu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Isesaki Municipal Hospital, Department of Cardiovascular Medicine, Isesaki (Japan); Ueda, Tetsuya [Fujioka General Hospital, Division of Cardiology, Fujioka (Japan); Sasaki, Toyoshi [Takasaki General Medical Center, Division of Cardiology, Takasaki (Japan); Nakahara, Takehiro; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi (Japan)

    2016-02-15

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m{sup 2}] undergoing stress {sup 99m}Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  10. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    International Nuclear Information System (INIS)

    Kasama, Shu; Toyama, Takuji; Sato, Makito; Sano, Hirokazu; Ueda, Tetsuya; Sasaki, Toyoshi; Nakahara, Takehiro; Kurabayashi, Masahiko; Higuchi, Tetsuya; Tsushima, Yoshito

    2016-01-01

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m 2 ] undergoing stress 99m Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  11. Diagnostic pathway of integrated SPECT/CT for coronary artery disease

    International Nuclear Information System (INIS)

    Slart, Riemer H.J.A.; Tio, Rene A.; Zijlstra, Felix; Dierckx, Rudi A.

    2009-01-01

    Treatment strategy in patients with suspected coronary artery disease (CAD) is driven by symptomatology in combination with diagnostic evaluation of the extent and/or severity of atherosclerosis in the coronary arteries and ischemia in the myocardium, i.e., the anatomic and functional correlates of CAD. Whereas multislice row computed tomography (MSCT) has the advantage of detecting coronary atherosclerosis at its earliest stages, thereby allowing initiation of appropriate therapeutic measures well before development of obstructive CAD, myocardial perfusion imaging (MPI) SPECT can clarify the hemodynamic consequences of the anatomic findings on MSCT based on a functional assessment of myocardial blood flow. There is a lack of correlation between coronary artery calcium (CAC), coronary artery stenosis, and MPI SPECT. Therefore CAC scoring and stress MPI should be thus considered complementary approaches rather than exclusionary in the evaluation of the patient at risk for CAD. The integration of anatomic and functional information may provide additional information for the clinician by the improved risk stratification and diagnostic accuracy of integrated techniques. The majority of previous studies are based on a sequential flowchart, starting with either SPECT or CAC scoring that finally directs the therapeutic strategy. Patients at low risk for CAD can be selected for primary prevention, and patients at high risk for CAD can be directly selected for coronary angiography (CAG). The remaining group of patients at intermediate risk for CAD can be substratified into lower- and higher-risk categories based on the presence or absence of stress-induced ischemia on MPI SPECT and CAC scoring. An integration of SPECT and CAC as a starting point for CAD detection in symptomatic patients at intermediate risk for CAD may facilitate a tailored diagnostic as well as therapeutic approach. Finally, using SPECT/CT, MPI SPECT, and CAC findings may be completed with CT angiography

  12. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  13. Serum Tumor Necrosis Factor-alpha associates with Myocardial Oxygen Demand and Exercise Tolerance in Postmenopausal Women.

    Science.gov (United States)

    Carter, Stephen J; Bryan, David R; Neumeier, William H; Glasser, Stephen P; Hunter, Gary R

    2018-01-01

    The functional implications of serum tumor necrosis factor-alpha (TNF-α), a marker of oxidative stress, on hemodynamic parameters at rest and during physical exertion are unclear. The aims of this investigation were to examine the independent associations of TNF-α on myocardial oxygen demand at rest and during submaximal exercise, while also evaluating the association of TNF-α on exercise tolerance. Forty, postmenopausal women, provided blood samples and completed a modified-Balke protocol to measure maximal oxygen uptake (VO 2max ). Large artery compliance was measured by pulse contour analyses while rate-pressure product (RPP), an index of myocardial oxygen demand, was measured at rest and during two submaximal workloads (i.e., ≈55% and ≈75% VO 2max ). RPP was calculated by dividing the product of heart rate and systolic blood pressure (via auscultation) by 100. Exercise tolerance corresponded with the cessation of the graded exercise test. During higher-intensity exertion, ≈75% VO 2max , multiple linear regression revealed a positive association ( r = 0.43; p = 0.015) between TNF-α and RPP while adjusting for maximal heart rate, VO 2max , large artery compliance, and percent body fat. Path analyses revealed a significant indirect effect of large artery compliance on exercise tolerance through TNF-α, β = 0.13, CI [0.03, 0.35], indicating greater levels of TNF-α associated with poorer exercise tolerance. These data suggest TNF-α independently associates with myocardial oxygen demand during physical exertion, thus highlighting the utility of higher-intensity efforts to expose important phenomena not apparent at rest. TNF-α also appears to be indirectly associated with the link between large artery compliance and exercise tolerance.

  14. Low Intensity Physical Exercise Attenuates Cardiac Remodeling and Myocardial Oxidative Stress and Dysfunction in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    C. Gimenes

    2015-01-01

    Full Text Available We evaluated the effects of a low intensity aerobic exercise protocol on cardiac remodeling and myocardial function in diabetic rats. Wistar rats were assigned into four groups: sedentary control (C-Sed, exercised control (C-Ex, sedentary diabetes (DM-Sed, and exercised diabetes (DM-Ex. Diabetes was induced by intraperitoneal injection of streptozotocin. Rats exercised for 9 weeks in treadmill at 11 m/min, 18 min/day. Myocardial function was evaluated in left ventricular (LV papillary muscles and oxidative stress in LV tissue. Statistical analysis was given by ANOVA or Kruskal-Wallis. Echocardiogram showed diabetic groups with higher LV diastolic diameter-to-body weight ratio and lower posterior wall shortening velocity than controls. Left atrium diameter was lower in DM-Ex than DM-Sed (C-Sed: 5.73±0.49; C-Ex: 5.67±0.53; DM-Sed: 6.41±0.54; DM-Ex: 5.81±0.50 mm; P<0.05 DM-Sed vs C-Sed and DM-Ex. Papillary muscle function was depressed in DM-Sed compared to C-Sed. Exercise attenuated this change in DM-Ex. Lipid hydroperoxide concentration was higher in DM-Sed than C-Sed and DM-Ex. Catalase and superoxide dismutase activities were lower in diabetics than controls and higher in DM-Ex than DM-Sed. Glutathione peroxidase activity was lower in DM-Sed than C-Sed and DM-Ex. Conclusion. Low intensity exercise attenuates left atrium dilation and myocardial oxidative stress and dysfunction in type 1 diabetic rats.

  15. Myocardial involvement in diabetic patients evaluated by exercise thallium-201 scintigraphy and cardiac catheterization

    International Nuclear Information System (INIS)

    Mizuno, Sumio; Genda, Akira; Nakayama, Akira; Igarashi, Yutaka; Takeda, Ryoyu

    1985-01-01

    To evaluate myocardial involvement in diabetes mellitus, we studied 39 patients with negative double-Master's test and without hypertension by exercise thallium-201 (Tl-201) myocardial scintigraphy using a bicycle ergometer. Among the 39 patients, 12 (30.8 %) showed filling defects in the scintigrams (positive cases), including eight with stress-induced defects and four with fixed defects. The positive cases had higher scores of diabetic complications (3.6 +- 2.4 vs 2.1 +- 1.8; p < 0.05) and longer durations of diabetes as compared with those of the negative cases. The frequency of insulin therapy was also greater in the positive cases. Eleven patients (5 positive and 6 negative cases) who underwent cardiac catheterization had no significant stenotic lesions of their coronary arteries. However, all of the positive cases showed abnormal wall motion, mainly hypokinesis, by left ventriculography (LVG). The abnormalities of the LVG corresponded to the findings of the scintigrams (i.e. filling defects and decrease in washout ratios by circumferential profile analysis). These results suggest that in some diabetics myocardial involvement exists in the early stage without overt cardiac disease and exercise Tl-201 scintigraphy is useful in detecting pre-clinical cardiomyopathy. Cardiomyopathy in diabetics seems to be due to disturbances of the myocardial microcirculation. (author)

  16. Evaluation of thallium-201 myocardial emission computed tomography based on a comparison with postmortem findings

    International Nuclear Information System (INIS)

    Nagashima, Jun-ichi; Yamada, Hideo; Ohkawa, Shin-ichiro; Yonamine, Shigemichi; Nishino, Hideo; Yamagata, Atsushi; Suzuki, Yasuko; Tanno, Munehiko; Chiba, Kazuo

    1986-01-01

    The correlative study of myocardial perfusion assessed by 201 Tl myocardial ECT with the pathological finding of the heart was performed in 10 autopsied cases with mean age of 77 years old (range: 60 - 90 y). In 6 cases with myocardial infarction (MI) 7 perfusion defects were observed, that was, 3 in anteroseptal wall, 1 in anterolateral wall and 3 in posterior wall on the images of SPECT. Seven MIs were also found in postmortem examination. Six MIs were observed at autopsy corresponding to perfusion defect on SPECT images. In one myocardial perfusion defect at inferoposterior portion on SPECT, a non-transmural MI was found at anteroseptum. In one case with valvular disease a false positive result was obtained at posterior wall where neither myocardial necrosis nor fibrosis was observed at autopsy. This case had aortic stenosis due to bicuspid aortic valve by autopsy. The ventricle was devided into 16 segments in each of 4 short axial images to evaluate extent of MI. SPECT for extent of MI showed sensitivity of 81.9 %, specificity of 96.0 % and diagnostic accuracy of 92.5 %. False negative segment was apt to be observed at the surrounding of non-transmural MI or basal half of left ventricle (LV) with transmural MI, while false positive segment was at posterior portion of basal half of LV. It was concluded that myocardial ECT was useful for evaluation of the site and extent of MI. (author)

  17. The clinical value of 99Tcm-N-NOET exercise and delayed myocardial perfusion imaging in patients with hypertension

    International Nuclear Information System (INIS)

    Wei Hua; Li Sijin; Liu Jianzhong; Wu Zhifang; Liu Haiyan; Hu Guang; Wang Jin; Li Qing

    2010-01-01

    Objective: To investigate clinical significance of the 99 Tc m -bis (N-ethoxy-N-ethyl-dithiocar-bamato) nitridotechnetium ( 99 Tc m -N-NOET) exercise and delayed myocardial perfusion imaging (MPI) in hypertensive patients. Methods: Sixty patients with hypertension and 19 normal subjects were carried out 99 Tc m -N-NOET exercise and delayed MPI, and analyzed the results of MPI, exercise electrocardiography (ECG), cardiac function parameters end-diastolic volume (EDV), end-systolic volume (ESV), left ventricular ejection fraction (LVEF), triangle open LVEF (LVEF exercis-LVEF delay) and coronary angiography (CAG). Results: 1) Sixty patients with hypertension, 22 cases (36.7%) of exercise ECG were abnormal, 16 cases (26.7%) were the chest tightness in exercise, 13 cases (21.7%) were blood pressure excessive reaction in exercise; control group, 2 cases (10.5%) of exercise ECG were abnormal, 1 case (5.3%, 1/19) was chest tightness in exercise, no person was blood pressure response in excessive. 2) The positive rate of myocardial perfusion in hypertensive group was significantly higher than the control group (31.75%vs. 5.30%, P 0.05), triangle open LVEF 2 =4.501, P 2 =0.25, P>0.05). The sensitivity, specificity and accuracy of 99 Tc m -N-NOET MPI were 72.7%, 87.5% and 78.9%. Conclusions: 1) 99 Tc m -N-NOET exercise and delayde MPI can diagnose whether hypertension patients with myocardial ischemia or not. 2) triangle open LVEF of hypertensive patients reduced, triangle open LVEF is lower in hypertensive patients of MPI-positive. (authors)

  18. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  19. Early diagnosis of interferon-induced myocardial disorder in patients with chronic hepatitis C. Evaluation by myocardial imaging with 123I-BMIPP

    International Nuclear Information System (INIS)

    Kondo, Yuki; Yukinaka, Michiko; Nomura, Masahiro; Nakaya, Yutaka; Ito, Susumu

    2000-01-01

    Interferon (IFN) therapy for chronic hepatitis C is sometimes associated with cardiac complications. In the present study, we performed myocardial imaging with 123 I-labeled β-methyl-p-iodophenylpentadecanoic acid ( 123 I-BMIPP) in order to evaluate myocardial disorders caused by IFN. We studied 40 healthy subjects (H group) and 25 patients with chronic hepatitis C who had been treated with IFN (IFN group). A Holter electrocardiogram (ECG) was performed and the autonomic nervous function was assessed by analyzing the spectral variability and 1/f fluctuation of heart rate. Myocardial planner imaging with 123 I-BMIPP was performed to obtain the time activity curve for 20 min immediately after administration of 123 I-BMIPP (dynamic study). Early and delayed myocardial single photon emission computed tomography (SPECT) images were expressed as Bull's eyes and the myocardium was divided into four segments to calculate the washout rate for each segment on early and late SPECT images (early and late SPECT study). No significant differences in autonomic nervous function were observed between the two groups in heart rate variability. In a dynamic study, the reduction rate from the time activity curve was significantly higher in the IFN group compared with the H group (reduction rate, IFN group, 5.3±3.7% vs H group, 1.2±3.3%; P 123 I-BMIPP myocardial scintigraphy examination several months after IFN therapy. These results indicate that metabolic disorders of fatty acids caused by IFN therapy can be detected before abnormalities are observed by Holter-ECG or echocardiography. (author)

  20. Early diagnosis of interferon-induced myocardial disorder in patients with chronic hepatitis C: evaluation by myocardial imaging with 123I-BMIPP.

    Science.gov (United States)

    Kondo, Y; Yukinaka, M; Nomura, M; Nakaya, Y; Ito, S

    2000-01-01

    Interferon (IFN) therapy for chronic hepatitis C is sometimes associated with cardiac complications. In the present study, we performed myocardial imaging with 123I-labeled beta-methyl-p-iodophenylpentadecanoic acid (123I-BMIPP) in order to evaluate myocardial disorders caused by IFN. We studied 40 healthy subjects (H group) and 25 patients with chronic hepatitis C who had been treated with IFN (IFN group). A Holter electrocardiogram (ECG) was performed and the autonomic nervous function was assessed by analyzing the spectral variability and 1/f fluctuation of heart rate. Myocardial planner imaging with 123I-BMIPP was performed to obtain the time activity curve for 20min immediately after administration of 123I-BMIPP (dynamic study). Early and delayed myocardial single photon emission computed tomography (SPECT) images were expressed as Bull's eyes and the myocardium was divided into four segments to calculate the washout rate for each segment on early and late SPECT images (early and late SPECT study). No significant differences in autonomic nervous function were observed between the two groups in heart rate variability. In a dynamic study, the reduction rate from the time activity curve was significantly higher in the IFN group compared with the H group (reduction rate, IFN group, 5.3 +/- 3.7% vs H group, 1.2 +/- 3.3%; P acids caused by IFN was reversed on the second 123I-BMIPP myocardial scintigraphy examination several months after IFN therapy. These results indicate that metabolic disorders of fatty acids caused by IFN therapy can be detected before abnormalities are observed by Holter-ECG or echocardiography.

  1. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  2. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    International Nuclear Information System (INIS)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo; Sakata, Hitomi; Ishihara, Tadayuki

    2001-01-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ( 201 Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting 201 Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by 201 Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting 201 Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  3. Clinical usefulness of 123I-labeled 15-iodophenyl 3-methyl pentadecanoic acid (BMIPP) myocardial SPECT in coronary artery disease

    International Nuclear Information System (INIS)

    Ito, Kazuki

    1998-01-01

    123 I-BMIPP (BMIPP) myocardial SPECT was carried out in 22 patients with acute myocardial infarction, in 20 patients with unstable angina pectoris, in 80 patients with effort angina pectoris and in 25 patients with vasospastic angina pectoris. In a study of patients with acute myocardial infarction, BMIPP uptake was less than thallium perfusion in areas of myocardial infarction. Such discordant BMIPP/thallium uptake was often observed in areas with recanalized arteries, and in those with abnormal wall motion. In the areas showing discordant BMIPP/thallium uptake, the wall motion abnormalities improved in the chronic phase after recanalization therapy. Therefore, the discordant BMIPP/thallium uptake might represent asynergic but viable regions, and might be valuable in predicting the improvement of wall motion abnormalities. In a study of patients with unstable angina pectoris, the severity of regional wall motion abnormality was significantly correlated with severity of BMIPP uptake. BMIPP imaging well visualized the culprit regions in patients with unstable angina pectoris. In a study of patients with effort angina pectoris, the abnormal BMIPP images were associated with severe coronary artery stenosis of more than 90% and with multivessel stenosis. BMIPP imaging could detect patients with functionally severe coronary artery disease and help to guide coronary angioplasty in patients with effort angina. In a study of patients with vasospastic angina pectoris, metabolic abnormality assessed by BMIPP was associated with left ventricular asynergy and spastic regions. Those abnormalities also correlated inversely with the period from the last attack, and improved after medical treatment. (K.H.)

  4. Mapping of the image quality in myocardial scintigraphy: A national study

    International Nuclear Information System (INIS)

    Ohlson, Maria; Gustafsson, Agnetha; Gretarsdottir, Jakobina; Olsson, Eva; Johansson, Lena

    2008-04-01

    The aim of this study was to make a survey over the physical parameters and how they affect the image quality and the final diagnosis for myocardial perfusion SPECT in Sweden. Another aim was to evaluate the need for standardized acquisition and processing protocols for myocardial perfusion SPECT. All thirty nuclear medicine departments in Sweden that perform myocardial perfusion SPECT participated in the study. A thorax heart phantom was used to simulate two patients. All studies were acquired and processed with the parameters used clinically in each hospital respectively. A quantitative and a qualitative evaluation were performed. At each hospital, the local nuclear medicine physician interpreted the images as if they were true patient images. There are great differences in the acquiring and processing parameters used in myocardial perfusion SPECT studies in Sweden. The image quality varies greatly for the different hospital but was approved for the majority of the hospitals. Images from two hospitals were considered to be too poor to be diagnosed. The interpretations of the local nuclear medicine physicians differ but the majority has reported an adequate diagnosis. One third of the hospitals have reported false positive defects. All steps in the chain from the acquisition to the evaluation of the medicine physician must be performed with high quality. The determinative factors are the noise reduction filter, the orientation of the slices in the heart and the judgement of the local medicine physician. The acquiring and processing parameters proposed by EANM should be used. The hospitals are also recommended to investigate in the time and resources available, in order to educate all staff involved in the evaluation of myocardial studies

  5. Two dimensional polar display of cardiac blood pool SPECT

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio; Takahashi, Taku; Takishima, Teruo; Hasegawa, Noriko; Hashimoto, Masanori; Ohno, Ken

    1989-01-01

    A new method of ECG gated cardiac blood pool SPECT to illustrate the left ventricular (LV) wall motion in a single static image, two dimensional polar display (2DPD), was described. Circumferential profiles of the difference between end diastolic and end systolic short axis images of the LV were displayed in a similar way to the bull's eye plot of 201 Tl myocardial SPECT. The diagnoses by 2DPDs agreed with those by cinematic displays of ECG gated blood pool SPECT in 74 out of 84 segments (85.5%) of abnormal motion, and 155 out of 168 segments (80.3%) of normal motion. It is concluded that 2DPD can evaluate regional wall motion by a single static image in a significant number of patients, and is also useful in comparing with the bull's eye image of 201 Tl myorcardial SPECT. (orig.)

  6. Clinical evaluation of efonidipine hydrochloride in angina pectoris. Evaluation in exercise 201Tl myocardial scintigraphy

    International Nuclear Information System (INIS)

    Hori, Masatsugu; Nishimura, Tsunehiko

    1996-01-01

    Clinical usefulness of once-daily administration of 20 to 60 mg of efonidipine hydrochloride and coronary hemodynamics during exercise 201 Tl myocardial scintigraphy were investigated in patients with angina pectoris. Out of 11 patients enrolled in this study, 9 patients were included in the evaluation of patients' impression, in improvement rating in subjective symptoms, in the analysis of the exercise test, in the improvement rating of images on 201 Tl myocardial scintigraphy, and in the global improvement rating, while 10 patients were included in the overall safety rating. Four patients in improvement rating in subjective symptoms, 2 in improving rating in the exercise test, and 5 in the global improvement rating were rated 'improved' or better. In the improvement rating on the exercise 201 Tl myocardial scintigraphy image, reduction of the image was observed in 5 patients, 3 out of which were evaluated as 'improved' or better. A distinctive reduction of ischemic regions was observed in 2 patients out of the 3. A significant decrease in the number of angina pectoris events and a decreasing tendency in consumption of fast-acting nitrates were observed in spite of the low number of the patients studied. An adverse effect was observed in 1 patient and abnormal laboratory values were observed in 2 patients which were improved promptly after withdrawal of the drug. It was in 7 patients evaluated as 'no problem', while in 4 patients it was evaluated as 'useful' or more. (author)

  7. Comparison of stress-rest and rest-stress one day myocardial perfusion scintigraphies in detecting coronary artery diseases

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Min, Jung Jun; Song, Ho Cheon; Kim, Ji Yeul

    1997-01-01

    It has been shown that both rest and stress myocardial perfusion imaging with technetium agents can be performed on the same day using two different doses injected within few hours. The purpose of this study was to compare the two protocols (stress-rest and rest-stress) in detecting coronary artery diseases. One hundred and sixty patients (101 males, 59 females, mean age 57±9 years) and 120 patients (79 males, 41 females, mean age 59±10 years) underwent stress-rest myocardial perfusion SPECT and rest-stress myocardial perfusion SPECT, respectively. All of them underwent both myocardial perfusion SPECT and coronary angiography within 1 month. A coronary stenosis was considered significant when it compromised the luminal diameter by ≥50%. The chi square test was used to compare differences in sensitivity, specificity and accuracy between the two groups. The overall sensitivity, specificity and accuracy of stress-rest protocol were 99%, 35% and 68%, respectively. Those of rest-stress protocol were 96%, 47% and 78%, respectively. There was no difference between the two protocols in identifying individual diseased coronary artery branches. Therefore, one day stress-rest and rest-stress myocardial SPECT using 99m Tc agents were comparable and were very sensitive tests in detecting coronary artery diseases

  8. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  9. Symptomatic relief precedes improvement of myocardial blood flow in patients under spinal cord stimulation

    Directory of Open Access Journals (Sweden)

    Koulousakis Athanassios

    2005-05-01

    Full Text Available Abstract Background Spinal cord electrical stimulation (SCS has shown to be a treatment option for patients suffering from angina pectoris CCS III-IV although being on optimal medication and not suitable for conventional treatment strategies, e.g. CABG or PTCA. Although many studies demonstrated a clear symptomatic relief under SCS therapy, there are only a few short-term studies that investigated alterations in cardiac ischemia. Therefore doubts remain whether SCS has a direct effect on myocardial perfusion. Methods A prospective study to investigate the short- and long-term effect of spinal cord stimulation (SCS on myocardial ischemia in patients with refractory angina pectoris and coronary multivessel disease was designed. Myocardial ischemia was measured by MIBI-SPECT scintigraphy 3 months and 12 months after the beginning of neurostimulation. To further examine the relation between cardiac perfusion and functional status of the patients we measured exercise capacity (bicycle ergometry and 6-minute walk test, symptoms and quality of life (Seattle Angina Questionnaire [SAQ], as well. Results 31 patients (65 ± 11 SEM years; 25 male, 6 female were included into the study. The average consumption of short acting nitrates (SAN decreased rapidly from 12 ± 1.6 times to 3 ± 1 times per week. The walking distance and the maximum workload increased from 143 ± 22 to 225 ± 24 meters and 68 ± 7 to 96 ± 12 watt after 3 months. Quality of life increased (SAQ significantly after 3 month compared to baseline, as well. No further improvement was observed after one year of treament. Despite the symptomatic relief and the improvement in maximal workload computer based analysis (Emory Cardiac Toolbox of the MIBI-SPECT studies after 3 months of treatment did not show significant alterations of myocardial ischemia compared to baseline (16 patients idem, 7 with increase and 6 with decrease of ischemia, 2 patients dropped out during initial test phase

  10. Evaluation of attenuation correction, scatter correction and resolution recovery in myocardial Tc-99m MIBI SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Larcos, G.; Hutton, B.F.; Farlow, D.C.; Campbell- Rodgers, N.; Gruenewald, S.M.; Lau, Y.H. [Westmead Hospital, Westmead, Sydney, NSW (Australia). Departments of Nuclear Medicine and Ultrasound and Medical Physics

    1998-06-01

    Full text: The introduction of transmission based attenuation correction (AC) has increased the diagnostic accuracy of Tc-99m MIBI myocardial perfusion SPECT. The aim of this study is to evaluate recent developments, including scatter correction (SC) and resolution recovery (RR). We reviewed 13 patients who underwent Tc-99m MIBI SPECT (two day protocol) and coronary angiography and 4 manufacturer supplied studies assigned a low pretest likelihood of coronary artery disease (CAD). Patients had a mean age of 59 years (range: 41-78). Data were reconstructed using filtered backprojection (FBP; method 1), maximum likelihood (ML) incorporating AC (method 2), ADAC software using sinogram based SC+RR followed by ML with AC (method 3) and ordered subset ML incorporating AC,SC and RR (method 4). Images were reported by two of three blinded experienced physicians using a standard semiquantitative scoring scheme. Fixed or reversible perfusion defects were considered abnormal; CAD was considered present with stenoses > 50%. Patients had normal coronary anatomy (n=9), single (n=4) or two vessel CAD (n=4) (four in each of LAD, RCA and LCX). There were no statistically significant differences for any combination. Normalcy rate = 100% for all methods. Physicians graded 3/17 (methods 2,4) and 1/17 (method 3) images as fair or poor in quality. Thus, AC or AC+SC+RR produce good quality images in most patients; there is potential for improvement in sensitivity over standard FBP with no significant change in normalcy or specificity

  11. Contamination of clothing and other items by sweat during exercise 201Tl myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yokoo, Shigeki; Niio, Yasuo; Yamamoto, Tomoaki; Miyashita, Makoto

    1999-01-01

    We measured the radioactivity on patient's upper and lower garments, towels, broad sashes for the bust, and electrodes contaminated by sweat due to exercise 201 Tl myocardial perfusion scintigraphy. In measuring activity, a scintillation survey meter adjusted to the energy of 201 Tl was used. In measuring the radioactivity of clothing, more than 4 Bq/cm 2 was considered to be a significant level of contamination. We detected contamination in 30% of upper garments and towels, 19% of broad sashes, 8% of lower garments and 4% of electrodes. Among these materials, several items of clothing and other items showed contamination exceeding 40 Bq/cm 2 . Towels were remarkably contaminated, with one towel showing a maximum contamination level of 420 Bq/cm 2 . Examinations done by exercise 201 Tl myocardial perfusion scintigraphy often result in the contamination of clothing and other items through sweating. This contamination is especially common in summer, particularly in upper garments and towels. The contamination ratio for towels was over 50%. The contamination ratio increased as the level of exercise became more difficult. When the exercise load was more than 100 W, the contamination ratio was 50%. In cases of extreme contamination, images of contaminated upper garments could be obtained by the scintigraphy camera. The areas of high activity on the images seemed to correspond to areas of the body where sweating was profuse. Based on these results, we should pay close attention to the handling of clothing and other items used in exercise testing by 201 Tl myocardial perfusion scintigraphy and the points used in measuring contaminated clothing and other items after testing. (author)

  12. Myocardial uptake and clearance of thallium-201 in normal subjects: comparison of dipyridamole-induced hyperemia with exercise stress

    International Nuclear Information System (INIS)

    Ruddy, T.D.; Gill, J.B.; Finkelstein, D.M.; Strauss, H.W.; McKusick, K.A.; Okada, R.D.; Boucher, C.A.

    1987-01-01

    Thallium-201 uptake and clearance after dipyridamole infusion may differ from that after exercise stress because the hemodynamic effects of these two interventions are different. In this study of normal volunteers, thallium kinetics after dipyridamole (n = 13) were determined from three serial image sets (early, intermediate and delayed) and from serial blood samples and compared with thallium kinetics after exercise (n = 15). Absolute myocardial thallium uptake was greater after dipyridamole compared with exercise (p less than 0.0001), although the relative myocardial distribution was similar. The myocardial clearance (%/h) of thallium was slower after dipyridamole than it was after exercise. Comparing dipyridamole and exercise, the differences in clearance were large from the early to the intermediate image (anterior, -11 +/- 17 versus 24 +/- 5, p = 0.0005; 50 degrees left anterior oblique, -7 +/- 11 versus 15 +/- 8, p = 0.004; 70 degrees left anterior oblique, 3 +/- 9 versus 21 +/- 6, p = 0.001). In contrast, the differences in clearance were small from the intermediate to the delayed image (anterior, 15 +/- 4 versus 20 +/- 2, p = 0.025; 50 degrees left anterior oblique, 15 +/- 4 versus 19 +/- 3, p = 0.13; 70 degrees left anterior oblique, 15 +/- 3 versus 18 +/- 2, p = 0.047). Thallium uptake and clearance in the liver, splanchnic region and spleen were greater after dipyridamole (p less than 0.001). Blood thallium levels were greater after dipyridamole (p less than 0.05) and cleared more slowly (p = 0.07). Thus, myocardial thallium-201 uptake and clearance after dipyridamole infusion differ from thallium kinetics after exercise. This difference is, in part, related to associated differences in extracardiac and blood kinetics. Diagnostic criteria for the detection of abnormal thallium-201 clearance must be specific for the type of intervention

  13. Oxygen uptake kinetics during and after exercise are useful markers of coronary artery disease in patients with exercise electrocardiography suggesting myocardial ischemia

    International Nuclear Information System (INIS)

    Tajima, Akihiko; Ohkoshi, Nobuyuki; Kawara, Tokuhiro; Aizawa, Tadanori; Itoh, Haruki; Maeda, Tomoko; Osada, Naohiko; Omiya, Kazuto; Wasserman, K.

    2009-01-01

    The aim of the current study was to determine if the slowed exercise oxygen uptake (VO 2 ) kinetics, which is developed by myocardial ischemia, would be accompanied by delayed recovery VO 2 kinetics in patients with coronary artery disease (CAD). Thirty-seven patients with significant ST depression during treadmill exercise underwent cardiopulmonary exercise testing with cycle ergometer. Measurements performed are the ratios of change in increase in oxygen (O 2 ) uptake relative to increase in work rate (ΔVO 2 /ΔWR) across anaerobic threshold (AT) and 1 mm ST depression point (ST-dep), the time constants of VO 2 during recovery (T 1/2 VO 2 ), stress radio-isotope scintigraphy and coronary angiography. Patients were divided into CAD positive (CAD+) and CAD negative (CAD-) groups, based on coronary angiography. In CAD+, ΔVO 2 /ΔWR decreased above AT and ST-dep, in contrast to CAD- patients. The T 1/2 VO 2 in CAD+ (103.1±13.0 s) was greater than that of CAD- (76.5±8.7 s) and showed negative correlations to the ratios of ΔVO 2 /ΔWR across AT and ST-dep. These parameters improved in the patients who underwent coronary bypass surgery. Exercise and recovery VO 2 kinetics were slowed when myocardial ischemia was provoked by exercise. Measurement of exercise and recovery VO 2 kinetics improve the accuracy of the exercise electrocardiogram diagnosis of CAD. (author)

  14. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve: A single-center prospective study.

    Science.gov (United States)

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-12-01

    The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD).We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC.FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = -0.584 and r = -0.568, respectively, both P system can predict FFR at an optimal cut-off of reserved.

  15. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    McQuaid, Sarah J; Hutton, Brian F

    2008-06-01

    Respiratory motion during myocardial perfusion imaging can cause artefacts in both positron emission tomography (PET) and single-photon emission computed tomography (SPECT) images when mismatches between emission and transmission datasets arise. In this study, artefacts from different breathing motions were quantified in both modalities to assess key factors in attenuation-correction accuracy. Activity maps were generated using the NURBS-based cardiac-torso phantom for different respiratory cycles, which were projected, attenuation-corrected and reconstructed to form PET and SPECT images. Attenuation-correction was performed with maps at mismatched respiratory phases to observe the effect on the left-ventricular myocardium. Myocardial non-uniformity was assessed in terms of the standard deviation in scores obtained from the 17-segment model and changes in uniformity were compared for each mismatch and modality. Certain types of mismatch led to artefacts and corresponding increases in the myocardial non-uniformity. For each mismatch in PET, the increases in non-uniformity relative to an artefact-free image were as follows: (a) cardiac translation mismatch, 84% +/- 11%; (b) liver mismatch, 59% +/- 10%, (c) lung mismatch from diaphragm contraction, 28% +/- 8%; and (d) lung mismatch from chest-wall motion, 6% +/- 7%. The corresponding factors for SPECT were (a) 61% +/- 8%, (b) 34% +/- 8%, (c) -2% +/- 7)% and (d) -4% +/- 6%. Attenuation-correction artefacts were seen in PET and SPECT images, with PET being more severely affected. The most severe artefacts were produced from mismatches in cardiac and liver position, whereas lung mismatches were less critical. Both cardiac and liver positions must, therefore, be correctly matched during attenuation correction.

  16. Prediction of wall motion improvement after coronary revascularization in patients with postmyocardial infarction. Diagnostic value of dobutamine stress echocardiography and myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Waku, Sachiko; Ohkubo, Tomoyuki; Takada, Kiyoshi; Ishihara, Tadashi; Ohsawa, Nakaaki; Adachi, Itaru; Narabayashi, Isamu

    1997-01-01

    The diagnostic value of dobutamine stress echocardiography, myocardial contrast echocardiography and dipyridamole stress thallium-201 single photon emission computed tomography (SPECT) for predicting recovery of wall motion abnormality after revascularization was evaluated in 13 patients with postmyocardial infarction. Seventeen segments showed severe wall motion abnormalities before revascularization. Nine segments which had relatively good Tl uptake on delayed SPECT images despite severely abnormal wall motion were opacified during myocardial contrast echocardiography, and showed improved wall motion after revascularization. In contrast, three segments which had poor Tl uptake and severely abnormal wall motion were not opacified during myocardial contrast echocardiography, and showed no improvement in wall motion during dobutamine stress echocardiography and after revascularization. The following three findings were assumed to be signs of myocardial viability: good Tl uptake on delayed SPECT images, improved wall motion by dobutamine stress echocardiography, and positive opacification of the myocardium by myocardiai contrast echocardiography. Myocardial contrast echocardiography had the highest sensitivity (100%) and negative predictive value (100%). Delayed SPECT images had the highest specificity (100%) and positive predictive value (100%). Dobutamine stress echocardiography had a sensitivity of 83.0%, specificity of 80.0%, positive predictive value of 90.9%, and negative predictive value of 66.7%, respectively. Myocardial contrast echocardiography showed the lowest specificity (60.0%). The techniques of dobutamine stress echocardiography and SPECT, though noninvasive, may underestimate wall motion improvement after revascularization. Further examination by myocardial contrast echocardiography is recommended to assess myocardial viability for determining the indications for coronary revascularization in spite of its invasiveness. (author)

  17. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  18. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    International Nuclear Information System (INIS)

    Winant, Celeste D; Aparici, Carina Mari; Bacharach, Stephen L; Gullberg, Grant T; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94 Tc-methoxyisobutylisonitrile ( 94 Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K 1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K 1 . For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94 Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99m Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal

  19. Defect images in stress thallium-201 myocardial scintigraphy in patients with complete left bundle branch block. Comparison of exercise stress and pharmacological stress

    International Nuclear Information System (INIS)

    Sasaki, Hideki; Shimizu, Mitsuyuki; Ogawa, Kazuhiko; Okazaki, Fumiko; Mizokami, Tsuneo; Kusaka, Masafumi; Uehara, Yoshiki; Taniguchi, Ikuo; Mochizuki, Seibu

    2007-01-01

    Stress thallium-201 ( 201 Tl) myocardial scintigraphy can demonstrate perfusion abnormalities, especially in the septum in patients with complete left bundle branch block (CLBBB) even with angiographically normal coronary arteries. Differences in the images between exercise and pharmacological stress 201 Tl myocardial scintigraphy were evaluated in patients with CLBBB and normal coronary arteries. Forty-five patients with CLBBB underwent exercise stress using treadmill or pharmacological (adenosine triphosphate) stress 201 Tl myocardial scintigraphy from October 1997 to February 2003. Patients with myocardial diseases were excluded, such as cardiomyopathy and coronary artery diseases detected by echocardiography and/or cardiac catheterization. The myocardial segment was classified according to the American Heart Association style for coronary artery disease. Peak blood pressure levels and heart rates were significantly higher in the exercise stress group than in the pharmacological stress group (p 201 Tl myocardial scintigraphy according to the stress method. Moreover, defects also occurred in areas other than the septum. Blood pressure and heart rate were involved in the mechanisms of defects in left bundle branch block. (author)

  20. SPECT-CT in the diagnosis of coronary artery disease; SPECT-CT in der Diagnostik der koronaren Herzerkrankung

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M. [Klinik und Poliklinik fuer Nuklearmedizin, Klinikum der Univ. Muenchen (Germany)

    2006-09-15

    Two-dimensional invasive coronary angiography (ICA), although showing high temporal and spatial resolution, is neither able to predict the physiologic relevance of a stenosis nor able to determine the prognosis of both symptomatic and asymptomatic patients. Therefore, the ICA can hardly represent the sole gold standard in clinical decision making. Additionally, the small but distinct morbidity and mortality rate of this method and the inconvenience of patients undergoing ICA have strengthened the search for a non-invasive alternative. Recent publications have shown high accuracy for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to ICA in detecting 'obstructive' coronary artery disease, defined as stenosis of more than 50%. Otherwise, although well known limitations of MDCT like motion artifacts or severe vessel calcifications could be clearly reduced with the newest scanner generation, this technique lacks of delivering exact lumen quantification compared to ICA in a clinical setting. Furthermore, there is evidence that exact quantification of coronary artery stenoses is of minor impact on clinical decision making, if lesion location and functional status are known. A first publication showed that combined imaging of MDCT angiography and PET myocardinal perfusion scanning with [{sup 13}N]ammonia was feasible with an integrated PET/CT scanner and reported high sensitivity and specificity to detect hemodynamically relevant coronary artery stenoses compared to the combination of PET plus ICA. However, PET perfusion tracers are not widely available at present and the well accepted reference for detecting myocardial ischemia, based on numerous publications, is myocardial perfusion SPECT (MPI). MPI is an established method for the non-invasive assessment of functional significance of coronary stenoses and delivers valuable information for risk stratification. Patients with stable angina and normal stress sestamibi

  1. Safety and efficacy of extracorporeal shock wave myocardial revascularization therapy for refractory angina pectoris.

    Science.gov (United States)

    Cassar, Andrew; Prasad, Megha; Rodriguez-Porcel, Martin; Reeder, Guy S; Karia, Darshak; DeMaria, Anthony N; Lerman, Amir

    2014-03-01

    To assess the safety and efficacy of extracorporeal shockwave myocardial revascularization (ESMR) therapy in treating patients with refractory angina pectoris. A single-arm multicenter prospective trial to assess safety and efficacy of the ESMR therapy in patients with refractory angina (class III/IV angina) was performed. Screening exercise treadmill tests and pharmacological single-photon emission computed tomography (SPECT) were performed for all patients to assess exercise capacity and ischemic burden. Patients were treated with 9 sessions of ESMR to ischemic areas over 9 weeks. Efficacy end points were exercise capacity by using treadmill test as well as ischemic burden on pharmacological SPECT at 4 months after the last ESMR treatment. Safety measures included electrocardiography, echocardiography, troponin, creatine kinase, and brain natriuretic peptide testing, and pain questionnaires. Fifteen patients with medically refractory angina and no revascularization options were enrolled. There was a statistically significant mean increase of 122.3±156.9 seconds (38% increase compared with baseline; P=.01) in exercise treadmill time from baseline (319.8±157.2 seconds) to last follow-up after the ESMR treatment (422.1±183.3 seconds). There was no improvement in the summed stress perfusion scores after pharmacologically induced stress SPECT at 4 months after the last ESMR treatment in comparison to that at screening; however, SPECT summed stress score revealed that untreated areas had greater progression in ischemic burden vs treated areas (3.69±6.2 vs 0.31±4.5; P=.03). There was no significant change in the mean summed echo score from baseline to posttreatment (0.4±5.1; P=.70). The ESMR therapy was performed safely without any adverse events in electrocardiography, echocardiography, troponins, creatine kinase, or brain natriuretic peptide. Pain during the ESMR treatment was minimal (a score of 0.5±1.2 to 1.1±1.2 out of 10). In this multicenter feasibility

  2. Leg 201Tl-SPECT in chronic exertional compartment syndrome

    International Nuclear Information System (INIS)

    Elkadri, N.; Slim, I.; Blondet, C.; Choquet, Ph.; Constantinesco, A.; Lecocq, J.

    2004-01-01

    Leg 201 Tl-SPECT in chronic exertional compartment syndrome Background: The chronic exertional compartment syndrome is one of the most frequent origins regarding leg pain due to sport training. The diagnosis can be established by invasive compartment pressure measurement. The aim of this study is to evaluate the role that could have 201 Tl-SPECT for patients with suspicion of compartment syndrome. Patients and methods: 51 leg 201 Tl-SPECT exams were performed (exercise - and rest without reinjection) in 49 patients; 28 had compartment syndrome confirmed by pressure measurement. About 100 MBq of 201 Tl were injected during exercise, when pain appeared or at least after 25 minutes exercise. We studied mean percentages of level uptake for each compartment, referred to the maximal uptake of both legs. Results: 47 compartments were concerned by compartment syndrome and 361 compartments were not. Scintigraphic patterns in compartments are reversible ischaemia (45%), uptake stability (36%) or reverse redistribution (19%); these patterns are not linked to compartment syndrome. However, there is a significant difference of rest 201 Tl level uptake between compartments with and without compartment syndrome and a significant correlation between muscular pressure measurement and rest level uptake. Conclusion: 201 Tl-SPECT shows that only ischaemia does not explain compartment syndrome. Moreover, it allows to predict pressure variation during exercise but it does not offer any interest in order to select patients for muscular invasive pressure measurement. (author)

  3. Surveillance study for creating the national clinical database relating to ECG-gated myocardial perfusion SPECT of asymptomatic ischemic heart disease in patients with type-2 diabetes mellitus. J-ACCESS 2 study design

    International Nuclear Information System (INIS)

    Kusuoka, Hideo; Yamasaki, Yoshimitsu; Izumi, Tohru; Kashiwagi, Atsunori; Kawamori, Ryuzo; Shimamoto, Kazuaki; Yamada, Nobuhiro; Nishimura, Tsunehiko

    2008-01-01

    Diabetes mellitus is an independent risk factor for acute myocardial infarction. Thus, a surveillance study was conducted as part of studies to create a national database related to electrocardiogram (ECG)-gated myocardial perfusion single-photon emission computed tomography (SPECT) of ischemic heart disease. Single-photon emission computed tomography was conducted in patients with type 2 diabetes mellitus and their prognoses will be followed for 3 years, stratified by patients' clinical background and SPECT findings. A total of 513 patients from 50 institutions were enrolled in this study, 297 of whom were men (age 66.2±0.4 years, mean±standard error of the mean (SEM)) and 261 women (age 67.8±0.5 years). They have a history of retinopathy (25.3%), neuropathy (19.9%), cerebrovascular disorder, chronic obstructive pulmonary disease, and photocoagulation. Major risk factors for present disease were hypertension (82.3%) and hyperlipidemia (79.7%). In 244 patients (129 men and 115 women), body mass index (BMI) was 25 or more. Fifty-two of them (10.1%) underwent coronary angiography; of these, 26 (50.0%) had no coronary artery lesions with 75% or more stenosis, and only 1 (1.9%) had a left main trunk with 50% or more stenosis. An overwhelming majority of patients (94.3%) underwent SPECT imaging by a 1-day stress-followed-by-rest procedure. Stress procedure was exercise in most (70.8%) patients, followed by dipyridamole infusion in 14.6%, adenosine infusion in 6.6%, and adenosine triphosphate infusion in 5.7%. Endpoint of stress examination was most often fatigue in lower limbs (40.7%), followed by completion of pharmacological stress protocol (28.7%), and achievement of target heart rate (26.3%). The largest number of patients (198, 38.6%) received 99m Tc-tetrofosmin at an initial dosage of 200-300 MBq (mean 331±3 MBq) followed by a second dosage of 700-800 MBq (mean 748±8 MBq). Among them, 491 (95.7%) received some kind of therapeutic drug: hypoglycemic drugs were

  4. General concepts of ventricular function, Myocardial perfusion, and exercise physiology relevant to nuclear cardiology

    International Nuclear Information System (INIS)

    Kronenberg, M.W.; Becker, L.C.

    1988-01-01

    Knowledge of ventricular mechanics, the physiology of the coronary circulation, and exercise physiology is necessary for the accurate interpretation of radionuclide ventriculographic and myocardial perfusion images. This chapter outlines these important basic concepts as applied to the whole heart

  5. Relationship between redistribution on exercise thallium-201 scintigraphy and repetitive ventricular premature beats in patients with recent myocardial infarction

    International Nuclear Information System (INIS)

    Tsuji, H.; Iwasaka, T.; Sugiura, T.; Shimada, T.; Nakamori, H.; Kimura, Y.; Inada, M.

    1991-01-01

    The relationship between myocardial ischemia detected by exercise thallium-201 scintigraphy and repetitive ventricular premature beats (VPBs) during ambulatory monitoring was evaluated in 57 patients with recent myocardial infarction. Multivariate analysis was performed to obtain the relatively important factor related to repetitive VPBs with the use of the following variables: age, redistribution, left ventricular ejection fraction, serum potassium and magnesium concentration, QRS score, left ventricular aneurysm, and the number of diseased vessels. Thirty-five patients had redistribution, but only three of them had repetitive VPBs during exercise testing. The average heart rate before 79% of 398 episodes of repetitive VPBs during ambulatory monitoring was in the range of 56 to 70/min. These data indicate that most of repetitive VPBs during ambulatory monitoring were not provoked by exercise-induced acute myocardial ischemia. However, redistribution was found to be an important factor associated with repetitive VPBs. The electrical abnormality relating to a substrate characterized by chronic reversible ischemia may explain the association between redistribution and repetitive VPBs

  6. Quantitative analysis of exercise 201Tl myocardial emission CT in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Okada, Mitsuhiro; Kawai, Naoki; Yamamoto, Shuhei

    1984-01-01

    The clinical usefulness of quantitative analysis of exercise thallium-201 myocardial emission computed tomography (ECT) was evaluated in coronary artery disease (CAD). The subjects consisted of 20 CAD patients and five normal controls. All CAD patients underwent coronary angiography. Tomographic thallium-201 myocardial imaging was performed with a rotating gamma camera, and long-axial and short-axial myocardial images of the left ventricle were reconstructed. The tomographic images were interpreted quantitatively using circumferential profile analysis. Based on features of regional myocardial thallium-201 kinetics, two types of abnormalities were studied: (1) diminished initial distribution (stress defect) and (2) slow washout of thallium-201, as evidenced by patients' initial thallium-201 uptake and 3-hour washout rate profiles which fell below the normal limits, respectively. Two diagnostic criteria including the stress defect and a combination of the stress defect and slow washout were used to detect coronary artery lesions of significance (>=75 % luminal narrowing). The ischemic volumes were also evaluated by quantitative analysis using thallium-201 ECT. The diagnostic accuracy of the stress defect criterion was 95 % for left anterior descending, 90 % for right, and 70 % for left circumflex coronary artery lesions. The combined criteria of the stress defect and slow washout increased detection sensitivity with a moderate loss of specificity for identifying individual coronary artery lesion. A relatively high diagnostic accuracy was obtained using the stress defect criterion for multiple vessel disease (75 %). Ischemic myocardial volume was significantly larger in triple vessel than in single vessel disease (p < 0.05) using the combined criteria. It was concluded that quantitative analysis of exercise thallium-201 myocardial ECT images proves useful for evaluating coronary artery lesions. (author)

  7. Abnormal myocardial capillary density in apical hypertrophic cardiomyopathy can be assessed by myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Moon, Jeonggeun; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Jang, Yangsoo; Chung, Namsik; Rim, Se-Joong

    2010-01-01

    Myocardial ischemia and dysfunction can occur in hypertrophic cardiomyopathy (HCM) because of the high muscle-to-blood ratio, even without significant coronary artery disease. Microbubbles reside only in the intravascular space and myocardial video-intensity during systole results mostly from microbubbles within capillaries. The hypothesis explored in the present study was that an abnormal capillary density in apical HCM (ApHCM) can be demonstrated using myocardial contrast echocardiography (MCE). The 56 patients were investigated (31 males, age 58±9 years; 33 ApHCM, 9 hypertensive left ventricular hypertrophy [LVH], 14 controls). MCE was performed with low-mechanical-index power modulation imaging. Tissue Doppler imaging to assess myocardial contractile function was obtained at the mitral annulus (S'), and 99m Tc-MIBI single photon emission computed tomography (SPECT) was also performed. All ApHCM patients exhibited perfusion defects at the hypertrophied segments in the systolic phase during MCE, whereas SPECT showed normal or rather increased perfusion at those sites. The cyclic variation of video-intensity was exaggerated in ApHCM when compared with the LVH or control group (% of [systolic video-intensity]/[diastolic video-intensity]: 33.0±12.3%, 88.3±19.2% and 79.4±13.9%, respectively [P<0.05]). Concurrently, MCE cyclic variation and perfusion defect size were related to decreased S' (P<0.05 for all). A perfusion defect at the hypertrophied segment, representing abnormal myocardial capillary density, was observed in ApHCM patients during MCE. The extent of MCE cyclic variation and the perfusion defect size both correlate with decreased myocardial contractile property in ApHCM. (author)

  8. The clinical use of myocardial gated SPECT imaging with 99TcmN-NOEt

    International Nuclear Information System (INIS)

    Li Sijin; Hu Guang; Liu Jianzhong; Tian Mei; Li Xianfeng; Zhang Wanchun; Wang Jin

    2002-01-01

    Objective: To evaluate the clinical value of 99 Tc m N-NOEt myocardial perfusion imaging comparing with 99 Tc m -MIBI. Methods: Twenty patients (pts) were divided into 2 groups. Group 1 (G1), left ventricular ejection fraction (LVEF) ≥ 50%, 13 pts, the mean age was (49.9 +- 14.7) years. Group 2 (G2), LVEF 0.05 vs G1). All the pst underwent gated SPECT imaging at 30 and 120 min after injection of 925 MBq 99 Tc m N-NOEt at rest, and the heart to lung (H/L) activity ratio was calculated. Of the 6 pts in G2 and 1 pt in G1 underwent the 99 Tc m -MIBI imaging within 3 days to the former imaging at 120 min after 99 Tc m -MIBI injection under the same condition as at 99 Tc m N-NOEt imaging. The left ventricles of the 7 pts were divided into 63 segments with 9 segments for each, and the four-point scoring system was used to evaluate the tracer uptake in the segments. Results: The H/L ratio was 1.47 +- 0.47 and 1.59 +- 0.53 (P > 0.50) respectively in G1 and was 0.72 +- 0.11 and 0.89 +- 0.11 (P 99 Tc m N-NOEt and 99 Tc m -MIBI for the presence of defects was 93.65%, Kappa +- s = 0.87 +- 0.12. The mean score was 2.0 +- 0.84 (MIBI) and 2.38 +- 0.84 (NOEt) respectively (P > 0.05). Conclusions: 1) If the lung uptake of 99 Tc m N-NOET showed higher, it suggested that the left ventricular function was poor. 2) The results of LVEF, EDV and ESV were accordant between MIBI and NOEt. 3) The extent and intensity of myocardial defect with NOEt imaging was more severe than that with MIBI

  9. Early exercise training after myocardial infarction prevents contractile but not electrical remodelling or hypertrophy

    NARCIS (Netherlands)

    V. Bito (Virginie); M.C. de Waard (Monique); L. Biesmans (Liesbeth); I. Lenaerts (Ilse); S. Ozdemir (Semir); E.D. van Deel (Elza); Y. Abdel-Mottaleb (Yousra); R. Driesen (Ronald); P. Holemans (Patricia); D.J.G.M. Duncker (Dirk); K.R. Sipido (Karin)

    2010-01-01

    textabstractAims: Exercise started early after myocardial infarction (MI) improves in vivo cardiac function and myofilament responsiveness to Ca2+. We investigated whether this represents partial or complete reversal of cellular remodelling. Methods and results: Mice with MI following left coronary

  10. Effects of a novel multimodal group intervention on myocardial perfusion in patients with coronary heart disease (CHD)

    International Nuclear Information System (INIS)

    Theissen, P.; Schicha, H.; Albus, C.; Koehle, K.; Griebenow, R.; Son, P.

    2002-01-01

    Full text: Recently, it could be shown that a multimodal intervention can promote health behavior in patients with CHD. Purpose of the actual study was to evaluate the effects on somatic endpoints, e.g. myocardial perfusion. We randomly assigned 77 patients (age 54 ± 6.9 y, male 87 %) with angiographically documented CHD to a multimodal group intervention plus standardized cardiological care (INT n=39) or standardized cardiological care only (CO n = 38). The intervention, for out-patients only, consisted of 77.5 hours of group-psychotherapy, relaxation and exercise training, and teaching lessons for one year. A Thallium myocardial perfusion scintigraphy (MyoSc) (after bicycle exercise test and at rest; 70 - 110 MBq Thallium-201, SPECT-technique, quantitative wash-out (w.-o.) analysis derived from polar maps) was performed at baseline, after 2 years, and 3 years, respectively: A w.-o. increase res. decrease by 5 % or more indicated an improved / a diminished myocardial perfusion within the affected coronary artery territory. Results were analyzed on an intention to treat basis. 70/77 patients (91 %) completed the study (drop-outs CO n=4, INT n=3). After 2 years (1st interval), there was no significant difference between groups. After 3 years (2nd interval) 36/39 patients (92.3 %) of INT showed a stable or improved myocardial perfusion, compared to 18/38 patients (47.4 %) of CO (p= 0.008). The recent data analysis demonstrates the extra benefit of a multimodal intervention, compared to standardized cardiological care alone, on myocardial perfusion in CHD patients. (author)

  11. Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride

    International Nuclear Information System (INIS)

    Staelens, Steven G.; Wit, Tim C. de; Lemahieu, Ignace A.; Beekman, Freek J.

    2008-01-01

    Thallous ( 201 Tl) chloride is a single-photon emission computed tomography (SPECT) tracer mainly used for assessing perfusion and viability of myocardial tissue. 201 Tl emits X-rays around 72 keV and gammas at 167 keV, and has a half-life of 73 h. Regulations allow an intrinsic contamination up to 3-5%, which is mainly caused by 200 Tl (368 keV; 26 h) and by 202 Tl (439 keV; 12.2 days). Contra-intuitive to the low-level percentages in which these contaminants are present, their impact may be significant because of much higher gamma camera sensitivity for these high-energy photon emissions. Therefore, we investigate the effects of the contaminants in terms of detected fractions of photons in projections and contrast degradation in reconstructed images. Acquisitions of a digital thorax phantom filled with thallous ( 201 Tl) chloride were simulated with a validated Monte Carlo tool, thereby, modelling 1% of contamination by 200 Tl and 202 Tl each. In addition, measurements of a thorax phantom on a dual-headed gamma camera were performed. The product used was contaminated by 0.17% of 200 Tl and 0.24% of 202 Tl at activity reference time (ART). This ART is specified by the manufacturer, thereby, accounting for the difference in half-lives of 201 Tl and its contaminants. These measurements were repeated at different dates associated with various contamination levels. Simulations showed that, with 1% of 200 Tl and 202 Tl, the total contamination in the 72 keV window can rise up to one out of three detected photons. For the 167keV window, the contamination is even more pronounced: more than four out of five detections in this photopeak window originate from contaminants. Measurements indicate that cold lesion contrast in myocardial perfusion SPECT imaging is at maximum close to ART. In addition to a higher noise level, relative contrast decreases 15% 2 days early to ART, which is explained by an increase in 200 Tl contamination. After ART, contrast decreased by 16% when

  12. Effect of thrombolytic therapy on exercise response during early recovery from acute myocardial infarction: a placebo controlled study

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Madsen, J K; Saunamäki, K I

    1992-01-01

    Several studies have shown that infarct size is reduced following thrombolytic treatment in patients with acute myocardial infarction. Exercise test variables, such as an impaired heart rate response during exercise, are known to be related to left ventricular function and patient prognosis follo...

  13. Myocardial Fibrosis in Competitive Triathletes Detected by Contrast-Enhanced CMR Correlates With Exercise-Induced Hypertension and Competition History.

    Science.gov (United States)

    Tahir, Enver; Starekova, Jitka; Muellerleile, Kai; von Stritzky, Alexandra; Münch, Julia; Avanesov, Maxim; Weinrich, Julius M; Stehning, Christian; Bohnen, Sebastian; Radunski, Ulf K; Freiwald, Eric; Blankenberg, Stefan; Adam, Gerhard; Pressler, Axel; Patten, Monica; Lund, Gunnar K

    2017-12-08

    This study analyzed the presence of myocardial fibrosis detected by late gadolinium-enhancement (LGE) cardiac magnetic resonance (CMR) in correlation with the performance of competitive triathletes objectified by an exercise test and individual competition history. Myocardial fibrosis detected by LGE CMR has been reported to occur in 0% to 50% of asymptomatic athletes. However, the cause and mechanisms of myocardial fibrosis are unclear. Eighty-three asymptomatic triathletes undergoing >10 training h per week (43 ± 10 years of age; 65% male) and 36 sedentary controls were studied by using LGE and extracellular volume (ECV) CMR. Parameters of physical fitness were measured by spiroergometry. Triathletes reported their lifetime competition results. LGE CMR revealed focal nonischemic myocardial fibrosis in 9 of 54 (17%) male triathletes (LGE + ) but in none of the female triathletes (p pressure (213 ± 24 mm Hg) than LGE - triathletes (194 ± 26 mm Hg; p 1,880 km completed during competition had the highest accuracy to predict LGE, with an area under the curve value of 0.876 (p pressure (p < 0.05) and the swimming race distance (p < 0.01) as independent predictors of LGE presence. Myocardial fibrosis in asymptomatic triathletes seems to be associated with exercise-induced hypertension and the race distances. There appears to be a safe upper limit, beyond which exercise may result in myocardial fibrosis. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Exercise training does not improve myocardial diastolic tissue velocities in Type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Nenonen Arja

    2007-09-01

    Full Text Available Abstract Background Myocardial diastolic tissue velocities are reduced already in newly onset Type 2 diabetes mellitus (T2D. Poor disease control may lead to left ventricular (LV systolic dysfunction and heart failure. The aim of this study was to assess the effects of exercise training on myocardial diastolic function in T2D patients without ischemic heart disease. Methods 48 men (52.3 ± 5.6 yrs with T2D were randomized to supervised training four times a week and standard therapy (E, or standard treatment alone (C for 12 months. Glycated hemoglobin (HbA1c, oxygen consumption (VO2max, and muscle strength (Sit-up were measured. Tissue Doppler Imaging (TDI was used to determine the average maximal mitral annular early (Ea and late (Aa diastolic as well as systolic (Sa velocities, systolic strain (ε and strain rate (έ from the septum, and an estimation of left ventricular end diastolic pressure (E/Ea. Results Exercise capacity (VO2max, E 32.0 to 34.7 vs. C 32.6 to 31.5 ml/kg/min, p = .001, muscle strength (E 12.7 to 18.3 times vs. C 14.6 to 14.7 times, p 1c (E 8.2 to 7.5% vs. C 8.0 to 8.4%, p = .006 improved significantly in the exercise group compared to the controls (ANOVA. Systolic blood pressure decreased in the E group (E 144 to 138 mmHg vs. C 146 to 144 mmHg, p = .04. Contrary to risk factor changes diastolic long axis relaxation did not improve significantly, early diastolic velocity Ea from 8.1 to 7.9 cm/s for the E group vs. C 7.4 to 7.8 cm/s (p = .85, ANOVA. Likewise, after 12 months the mitral annular systolic velocity, systolic strain and strain rate, as well as E/Ea were unchanged. Conclusion Exercise training improves endurance and muscle fitness in T2D, resulting in better glycemic control and reduced blood pressure. However, myocardial diastolic tissue velocities did not change significantly. Our data suggest that a much longer exercise intervention may be needed in order to reverse diastolic impairment in diabetics, if at all

  15. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing

    International Nuclear Information System (INIS)

    Nishida, Chikako; Okajima, Kaoru; Yamamoto, Takashi; Hattori, Ryuichi; Kudo, Takashi; Nishimura, Yasumasa

    2005-01-01

    The objective of this study was to examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and Tl-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high. (author)

  16. Impaired exercise-related myocardial uptake of technetium-99m-tetrofosmin in relation to coronary narrowing and diabetic state

    International Nuclear Information System (INIS)

    Sasao, Hisataka; Nakata, Tomoaki; Tsuchihashi, Kazufumi; Wakabayashi, Takeru; Nakahara, Norifumi; Doi, Atsushi; Hashimoto, Akiyoshi; Kobayashi, Hiroshi; Shimamoto, Kazuaki

    2001-01-01

    Despite the diagnostic efficacy of stress myocardial perfusion imaging, the correlation between the actual perfusion tracer activity and diseased state of a coronary artery has not been studied in detail. We estimated exercise-related perfusion augmentation in relation to disease states of a coronary artery in diabetic and non-diabetic patients by a newly developed quantitative technetium (Tc)-99m-tetrofosmin myocardial imaging technique. Tc-99m-tetrofosmin tomographic imaging with an exercise-rest protocol was performed in 26 stable coronary patients and in 8 age-matched controls. Percent increase (%IR) in myocardial count during symptom-limited submaximal exercise-stress was calculated in 16 non-infarcted polar map segments and in each coronary territory by a subtraction technique with corrections for physical decay and injected tracer doses, and the results were compared with those of angiographically quantified coronary diameter stenosis (%DS). Percent IR and peak heart rate during exercise showed a positive linear correlation both in coronary territories with significant stenosis (%DS≥75%) and in control or non-stenotic (%DS<75%) territories. The regression line in stenotic regions was, however, significantly (p<0.01) shifted downward compared to that in non-stenotic regions. Percent IR in stenotic regions showed a significant inverse correlation with %DS. Coronary stenosis of 75% or more was identified by a %IR cutoff value of 40% with 77% sensitivity, 70% specificity, and an accuracy of 72%. In coronary territories with a %DS of less than 75%, %IR in diabetic patients was significantly lower (46±15%) than that in non-diabetic patients (61±25%). Thus, blunted exercise-related augmentation of myocardial uptake of Tc-99m-tetrofosmin correlates with the severity of coronary narrowing and diabetic state. (author)

  17. Comparative study of dobutamine stress echocardiography and dual single-photon emission computed tomography (Thallium-201 and I-123 BMIPP) for assessing myocardial viability after acute myocardial infarction

    International Nuclear Information System (INIS)

    Yasugi, Naoko; Hiroki, Tadayuki

    2002-01-01

    Discordance between the 123 I-labelled 15-iodophenyl-3-R, S-methyl pentadecanoic acid (BMIPP) and 201 Tl findings may indicate myocardial viability (MV). This study compared dobutamine stress echocardiography (DSE) and single-photon emission computed tomography (SPECT) using the dual tracers for assessment of MV and prediction of functional recovery after acute myocardial infarction (AMI). DSE and dual SPECT were studied in 35 patients after AMI, of whom 28 underwent percutaneous coronary intervention in the acute stage. Dual SPECT was performed to compare the defect score of BMIPP and 201 Tl. The left ventricular wall motion score (WMS) was estimated during DSE and 6 months later to assess functional recovery of the infarct area. The rate of agreement of MV between dual SPECT and DSE was 89% (p 201 Tl were significantly smaller in patients with functional recovery than in those without. Assessment of MV using DSE concords with the results of dual SPECT in the early stage of AMI. DSE may have a higher predictive value for long-term functional recovery at the infarct area. However, a finding of positive MV by dual SPECT, without functional recovery, may indicate residual stenosis of the infarct-related artery, although the number of cases was small. Combined assessment by dual SPECT and DSE may be useful for detecting MV and jeopardized myocardium. Furthermore, the results suggest that functional recovery of dysfunctional myocardium may depend on the size of the infarct and risk area. (author)

  18. Is chronic ST segment elevation a marker of myocardial non viability in patients with Q wave anteroseptal MI? Correlation with myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Padma, S.; Zachariah, M.; Haridas, K.K.

    2004-01-01

    Persistence of ST segment elevation for more than 2-4 weeks in patients with acute antero septal transmural myocardial infarction (ASMI) is considered to be a specific marker of left ventricular aneurysm. Objective: We attempted to assess the face value of this statement by correlating the findings of 99m Tc Sestamibi Myocardial perfusion SPECT (MPSPECT), one of the most specific modalities of myocardial viability assessment with resting 12 lead ECG. METHOD: 240 ASMI patients (192:48 Male: Female pts, age range 36-71 yrs Mean 51±8 yrs) referred for risk stratification to our department between Jan 02 -Jan 04 were retrospectively analysed. The baseline demographic details and LV systolic function parameters were more or less the same for all these patients. The mean LV EF at rest was 40±6 %. All these patients fulfilled the following inclusion criteri 1) Patients with Q Wave ASMt more than 1 month old, 2) ECG at rest showing sinus rhythm, QRS 1.5 mm. Patients with atrial arrhythmias and bundle branch block were excluded. All these patients underwent same day rest stress gated 99m Tc MIBI/ tetrofosmin MPSPECT on a dual head variable angle gamma camera. Patients performed either conventional treadmill stress or taken up for pharmacological stress. LAD territory myocardial segments (i.e. apex, anterior, septal) were evaluated for the presence of reversible ischaemia / viable myocardium. Images were visually interpreted and using a 16 segment myocardial model quantification was also performed. Presence of reversible perfusion defects, uptake of MIBI at rest more than 40 % and myocardial systolic wall thickening (count increase by at least 10% during systole) were considered as markers of viability. Results' Patients were categorized into two groups. ST elevation positive i.e. patients with rest ST elevation > 1.5 mm (137 pts 57%) and ST elevation negative (103 pts 37%) by the rest ECG criteria. In ST positive group, 47/137 pts (34%) showed viability (mean viable

  19. Is chronic st segment elevation a marker of myocardial non viability in patients with Q wave anteroseptal mi? - correlation with myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Padma, S; Zachariah, M.; Haridas, K K

    2004-01-01

    Persistence of ST segment elevation for more than 2-4 weeks in patients with acute antero septal transmural myocardial infarction (ASMI) is considered to be a specific marker of left ventricular aneurysm. Objective: We attempted to assess the face value of this statement by correlating the findings of 99m -Tc Sestamibi Myocardial perfusion SPECT (MPSPECT), one of the most specific modalities of myocardial viability assessment with resting 12 lead ECG. Method: 240 ASMI patients (192:48 Male: Female pts, age range 36-71 yrs Mean 51±8 yrs) referred for risk stratification to our department between Jan 02 -Jan 04 were retrospectively analysed. The baseline demographic details and LV systolic function parameters were more or less the same for all these patients. The mean LV EF at rest was 40±6 %. All these patients fulfilled the following inclusion criteria: 1) Patients with Q Wave ASMI more than l month old, 2) ECG at rest showing sinus rhythm, QRS 1.5 mm. Patients with atrial arrhythmias and bundle branch block were excluded. All these patients underwent same day rest stress gated 99m Tc MIBI/ tetrofosmin MPSPECT on a dual head variable angle gamma camera. Patients performed either conventional treadmill stress or taken up for pharmacological stress. LAD territory myocardial segments (i.e. apex, anterior, septal) were evaluated for the presence of reversible ischaemia/viable myocardium. Images were visually interpreted and using a 16 segment myocardial model quantification was also performed. Presence of reversible perfusion defects, uptake of MIBI at rest more than 40% and myocardial systolic wall thickening (count increase by at least 10% during systole) were considered as markers of viability. Results: Patients were categorized into two groups. ST elevation positive i.e. patients with rest ST elevation > 1.5 mm (137 pts 57%) and ST elevation negative (103 pts 37%) by the rest ECG criteria. In ST positive group, 47/137 pts (34%) showed viability (mean viable

  20. Kinetic parameter estimation from SPECT cone-beam projection measurements

    International Nuclear Information System (INIS)

    Huesman, Ronald H.; Reutter, Bryan W.; Zeng, G. Larry; Gullberg, Grant T.

    1998-01-01

    Kinetic parameters are commonly estimated from dynamically acquired nuclear medicine data by first reconstructing a dynamic sequence of images and subsequently fitting the parameters to time-activity curves generated from regions of interest overlaid upon the image sequence. Biased estimates can result from images reconstructed using inconsistent projections of a time-varying distribution of radiopharmaceutical acquired by a rotating SPECT system. If the SPECT data are acquired using cone-beam collimators wherein the gantry rotates so that the focal point of the collimators always remains in a plane, additional biases can arise from images reconstructed using insufficient, as well as truncated, projection samples. To overcome these problems we have investigated the estimation of kinetic parameters directly from SPECT cone-beam projection data by modelling the data acquisition process. To accomplish this it was necessary to parametrize the spatial and temporal distribution of the radiopharmaceutical within the SPECT field of view. In a simulated chest image volume, kinetic parameters were estimated for simple one-compartment models for four myocardial regions of interest. Myocardial uptake and washout parameters estimated by conventional analysis of noiseless simulated cone-beam data had biases ranging between 3-26% and 0-28%, respectively. Parameters estimated directly from the noiseless projection data were unbiased as expected, since the model used for fitting was faithful to the simulation. Statistical uncertainties of parameter estimates for 10 000 000 events ranged between 0.2-9% for the uptake parameters and between 0.3-6% for the washout parameters. (author)

  1. Assessment of viability by quantitative evaluation of 24h-redistribution in 201-thallium myocardial scintigraphy (SPECT): A comparative study versus clinical follow-up after revascularisation

    International Nuclear Information System (INIS)

    Stirner, H.; Spreng, M.; Picker, D.; Pfafferott, C.

    1992-01-01

    Results of regional quantitative assessment of 24h-redistribution in routinely performed Thallium myocardial scintigraphy (SPECT) were compared to findings of coronary angiography/ventriculography and/or echocardiography as well as clinical status 6 months after revascularisation in up to now 34 patients. In respect of positive and negative predictive values evaluation of 24h-redistribution behaves best (81/100%) compared to perfusion and 3h-redistribution alone. Performing an additional 24h-study gives a gain of at least 80% of diagnostic information. (orig.) [de

  2. Myocardial perfusion scintigraphy in Germany. Results of the 2005 query and current status

    International Nuclear Information System (INIS)

    Lindner, O.; Burchert, W.; Bengel, F.M.; Zimmermann, R.; Dahl, J. vom; Schaefer, W.; Buell, U.; Schober, O.; Schwaiger, M.; Kluge, R.; Schaefers, M.

    2007-01-01

    The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine (DGN), in cooperation with the working group Nuclear Cardiology of the German Cardiac Society (DGK), decided to conduct a national survey on myocardial perfusion scintigraphy (MPS). Method: a questionnaire to evaluate MPS for the year 2005 was sent. Results: 346 completed questionnaires had been returned (213 private practices, 99 hospitals and 33 university hospitals). MPS of 112 707 patients were reported with 110 747 stress and 95 878 rest studies. The majority (> 75%) was performed with 99m Tc-MIBI or tetrofosmin. 201 Tl stress-redistribution was used in 22 637 patients (20%). The types of stress were exercise in 78%, vasodilation with adenosine or dipyridamol in 21% and dobutamine in 1%. 99.97% of all MPS were SPECT studies. Gated SPECT was performed in 36% of the stress and in 32% of the rest studies. An attenuation correction was used in 21%. 29 institutions (8%) performed gated SPECT (stress and rest) and attenuation correction. 47% of all MPS were requested by ambulatory care cardiologists, 17% by internists, 12% by primary care physicians, 21% by hospital departments and 2% by others. Conclusion: in Germany, MPS is predominantly performed with 99m Tc-perfusion agents. The common type of stress is ergometry. Gated SPECT and attenuation correction do not yet represent standards of MPS practice in Germany, which indicates some potential of optimization. (orig.)

  3. Effect of exercise training intensity on mitochondrial dynamics and mitophagy in post myocardial infarction rats

    Directory of Open Access Journals (Sweden)

    Babak Ebadi

    2018-06-01

    Full Text Available Myocardial infarction (MI is the most common type of heart disease. According to recent studies, mitochondrial dysfunction has been suggested as a central player in cardiac disease and evidences point out the association of mitochondrial morphology with development of heart diseases. Exercise training plays a protective role against cardiovascular disease. However, the role of exercise training on proteins involved in mitochondrial dynamics and mitophagy system are not well understood. Therefore, the aim of the present study was to investigate these on cardiac mitochondrial dynamic and mitophagy proteins in rats with myocardial infarction. The present study was post-test design experiment with the control group. after MI with ligation of the left anterior descending coronary artery (LAD and ensuring the creation of MI by echocardiography, male rats were subjected to high intensity interval training (HIIT, moderate (MIIT, low (LIIT, sedentary myocardial infarction (SED-MI and healthy control groups. After six weeks exercise, the levels of MFN2, DRP1, Parkin, P62 and PGC-1α proteins were measured by ELISA method. Data analysis showed that proteins levels of MFN2, PGC-1α, Parkin and P62 decreased significantly in SED-MI group compared to healthy control while DRP1 protein levels increased significantly (P≤0.05. Also, MFN2 and PGC-1α proteins increased in MIIT group compared with SED-MI group and DRP1 protein levels were significantly decreased (P≤0.05. Moderate-intensity interval training (MIIT resulted to improve mitochondrial fusion and fusion proteins in rats with myocardial infarction. While high and low intensity interval training (HIIT, LIIT, despite increasing MFN2 and PGC-1α and reducing DRP1, failed to improve fusion and mitochondrial fission

  4. Assessment of myocardial washout of Tc-99m-sestamibi in patients with chronic heart failure. Comparison with normal control

    Energy Technology Data Exchange (ETDEWEB)

    Kumita, Shin-ichiro; Seino, Yoshihiko; Cho, Keiichi; Nakajo, Hidenobu; Toba, Masahiro; Fukushima, Yoshimitsu; Takano, Teruo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan); Okamoto, Noriake [Bristol-Myers Squibb K.K., Tokyo (Japan)

    2002-06-01

    In contrast to {sup 201}TlCl, {sup 99m}Tc-sestamibi shows very slow myocardial clearance after its initial myocardial uptake. In the present study, myocardial washout of {sup 99m}Tc-sestamibi was calculated in patients with non-ischemic chronic heart failure (CHF) and compared with biventricular parameters obtained from first-pass and ECG-gated myocardial perfusion SPECT data. After administration of {sup 99m}Tc-sestamibi, 25 patients with CHF and 8 normal controls (NC) were examined by ECG-gated myocardial perfusion SPECT and planar data acquisition in the early and delayed (interval of 3 hours) phase. Left ventricular ejection fraction (LVEF, %), peak filling rate (PFR, sec{sup -1}), end-diastolic volume (LVEDV, ml) and end-systolic volume (LVESV, ml) were automatically calculated from the ECG-gated SPECT data. Myocardial washout rates over 3 hours were calculated from the early and delayed planar images. Myocardial washout rates in the CHF group (39.6{+-}5.2%) were significantly higher than those in the NC group (31.2{+-}5.5%, p<0.01). The myocardial washout rates for the 33 subjects showed significant correlations with LVEF (r=-0.61, p<0.001), PFR (r=-0.47, p<0.01), LVEDV (r=0.45, p<0.01) and LVESV (r=0.48, p<0.01). The myocardial washout rate of {sup 99m}Tc-sestamibi is considered to be a novel marker for the diagnosis of myocardial damage in patients with chronic heart failure. (author)

  5. Impaired coronary flow reserve is the most important marker of viable myocardium in the myocardial segment-based analysis of dual-isotope gated myocardial perfusion single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Lee, Won Woo; So, Young; Kim, Ki Bong; Lee, Dong Soo

    2014-01-01

    The aim of this study was to investigate the most robust predictor of myocardial viability among stress/rest reversibility (coronary flow reserve [CFR] impairment), 201 Tl perfusion status at rest, 201 Tl 24 hours redistribution and systolic wall thickening of 99m Tc-methoxyisobutylisonitrile using a dual isotope gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with coronary artery disease (CAD) who were re-vascularized with a coronary artery bypass graft (CABG) surgery. A total of 39 patients with CAD was enrolled (34 men and 5 women), aged between 36 and 72 years (mean 58 ± 8 standard in years) who underwent both pre- and 3 months post-CABG myocardial SPECT. We analyzed 17 myocardial segments per patient. Perfusion status and wall motion were semi-quantitatively evaluated using a 4-point grading system. Viable myocardium was defined as dysfunctional myocardium which showed wall motion improvement after CABG. The left ventricular ejection fraction (LVEF) significantly increased from 37.8 ± 9.0% to 45.5 ± 12.3% (p 201 Tl rest perfusion status (p = 0.024) were significant predictors of wall motion improvement. However, in multiple logistic regression analysis, stress/rest reversibility alone was a significant predictor for post-CABG wall motion improvement (p < 0.001). Stress/rest reversibility (impaired CFR) during dual-isotope gated myocardial perfusion SPECT was the single most important predictor of wall motion improvement after CABG.

  6. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  7. Pharmacologic intervention as an alternative to exercise stress

    International Nuclear Information System (INIS)

    Gould, K.L.

    1987-01-01

    Although thallium exercise imaging has served an important role in clinical cardiology, it is significantly limited by suboptimal sensitivity and specificity, particularly in asymptomatic man. The increasing recognition of silent myocardial ischemia, the significant prevalence of coronary artery disease in asymptomatic middle age men, and the frequent occurrence of myocardial infarction without preceding symptoms in 60% of cases emphasizes the need for a more definitive, noninvasive diagnostic test for the presence of coronary artery disease suitable for screening in asymptomatic or symptomatic patients. Intravenous dipyridamole combined with handgrip stress provides a potent stimulus for purposes of diagnostic perfusion imaging. Although planar and single photon emission computed tomography (SPECT) imaging also have played an important role, these techniques are seriously hindered by their inability to quantitate radiotracer uptake or image modest differences in maximum relative flow caused by coronary artery stenosis. Accordingly, the combination of dipyridamole-handgrip stress with positron imaging of myocardial perfusion has become a powerful diagnostic tool suitable for routine clinical use. With the availability of generator-produced rubidium-82, dedicated clinically oriented positron cameras, the routine application of positron imaging to clinical cardiology has become feasible. 75 references

  8. Prediction of infarct volume in patients undergoing reperfusion therapy by Tc-99m antimyosin SPECT

    International Nuclear Information System (INIS)

    Yasuda, T.; Leinbach, R.C.; Khaw, B.A.; Gold, H.K.; Strauss, H.W.

    1984-01-01

    The predictability of infarct volume by Tc-99m antimyosin SPECT was evaluated within 24 hours of chest pain and this was compared to the length of akinesis (AK) from the pre-discharge left ventriculogram (LVgram). Ten patients (pts) with acute myocardial infarction who underwent streptokinase thrombolytic therapy (success 8, failure 2) were subjects of this investigation. None had previous infarction. Average reperfusion time was within 4.5 hours and 20mCi of Tc-99m antimyosin was given intravenously within 8 hours after chest pain; SPECT imaging was performed within 18 hours after injection. Infarct volume was calculated from SPECT and expressed as grams of myocardial infarction (GMI). Ten days later, a 30 0 RAO contrast LVgram was recorded and the length of AK (corrected for magnification) was measured along the LV border at the end-diastolic phase and expressed as cm of AK. GMI and AK were measured independently without knowledge of each other. Results are given. The data demonstrate a good correlation of GMI and AK. Infarct volume can be measured by antimyosin SPECT within 24 hours of chest pain and predict residual LV dysfunction in pts undergoing reperfusion therapy

  9. Decreased perfusion in myocardial region of normal donor artery secondary to collateral development

    International Nuclear Information System (INIS)

    Koga, Y.; Takahashi, M.; Kojima, A.; Takaki, Y.; Tomiguchi, S.; Hirota, Y.; Kugiyama, K.; Yasue, H.; Hayasaki, K.; Kumamoto Saiseikai Hospital

    1992-01-01

    Thirty-one patients suffering from single vessel exertional angina with collaterals (Group A) were evaluated by stress 201 Tl myocardial emission CT (Tl-SPECT) with 16 controls of severely stenotic single vessel exertional angina without collaterals (Group B). Group A included 21 patients (68%) who showed an extensive perfusion defect in double artery myocardial regions, including the normal donor artery myocardial region (DMR). However, there were no such cases in Group B, giving a significant difference between these 2 groups (p < 0.001). Four patients in Group A, having a perfusion defect both in DMR and in the collateral dependent myocardial region (CMR) underwent a successful percutaneous transluminal coronary angioplasty (PTCA) with disappearance of collaterals. Tl-SPECT findings after PTCA showed no perfusion defect either in CMR or in DMR. This has been explained on the basis that the coronary collaterals stole blood and produced perfusion defect in DMR. (orig.)

  10. Myocardial perfusion scintigraphy 2007 in Germany. Results of the query and current status

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, O. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Burchert, W. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Arbeitsgemeinschaft Kardiovaskulaere Nuklearmedizin der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Bengel, F.M. [Cardiovascular Nuclear Medicine, Johns Hopkins Medical Institutions, Baltimore (United States); Arbeitsgruppe Nuklearkardiologische Diagnostik der Deutschen Gesellschaft fuer Kardiologie (Germany); Zimmermann, R. [Arbeitsgruppe Nuklearkardiologische Diagnostik der Deutschen Gesellschaft fuer Kardiologie (Germany); Medizinische Klinik, Klinikum Pforzheim GmbH, Pforzheim (Germany); Dahl, J. vom [Klinik fuer Kardiologie, Kliniken Maria Hilf GmbH, Moenchengladbach (Germany); Schaefer, W. [Klinik fuer Nuklearmedizin, Universitaetsklinikum Aachen (Germany); Schober, O. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster UKM (Germany); Schaefers, M. [Arbeitsgemeinschaft Kardiovaskulaere Nuklearmedizin der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster UKM (Germany)

    2009-07-01

    Aim: This third survey of the working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine in cooperation with the working group Nuclear Cardiology of the German Cardiac Society was to deliver information on the procedures and in particular on the development of myocardial perfusion scintigraphy (MPS) from 2005 to 2007. Method: 370 questionnaires (222 private practices (PP), 117 hospitals (HO), 31 university hospitals (UH)) were evaluated. Results: MPS of 114,374 patients were reported, 83% were investigated with {sup 99m}Tc-perfusion tracers. 76% [2006=74%] were performed in PP, 15% [2006=17%] in HO and 9% [2006=9%] in UH. Diabetics represented 21% of all MPS patients in 2007. Data of 215 institutions which participated all from 2005 to 2007 showed an increase in MPS of 2.3% (PP +6.8%, HO -4.5%, UH -18.2%). The type of stress was pharmacological in 27% [2006 = 27%]; 67% adenosine (of these 25% with exercise), 31% dipyridamole (of these 55% with exercise), and 2% dobutamine. Gated SPECT was performed in 47% [2006 = 42%] of all rest and in 44% [2006 = 39%] of all stress MPS. 61% [2006 = 83%] of all institutions did not apply perfusion scores. 20% [2006 = 24%] of the institutions reported changes in the use of MPS by competing methods. Conclusion: There is a small increase of MPS between 2005 and 2007 despite competing methods. Gated SPECT has experienced more acceptance, but is still underrepresented. As compared to the European average and general standards of MPS a considerable backlog accounts to pharmacological stress tests, gated SPECT and perfusion scores. (orig.)

  11. Myocardial perfusion scintigraphy 2007 in Germany. Results of the query and current status

    International Nuclear Information System (INIS)

    Lindner, O.; Burchert, W.; Bengel, F.M.; Zimmermann, R.; Dahl, J. vom; Schaefer, W.; Schober, O.; Schaefers, M.

    2009-01-01

    Aim: This third survey of the working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine in cooperation with the working group Nuclear Cardiology of the German Cardiac Society was to deliver information on the procedures and in particular on the development of myocardial perfusion scintigraphy (MPS) from 2005 to 2007. Method: 370 questionnaires (222 private practices (PP), 117 hospitals (HO), 31 university hospitals (UH)) were evaluated. Results: MPS of 114,374 patients were reported, 83% were investigated with 99m Tc-perfusion tracers. 76% [2006=74%] were performed in PP, 15% [2006=17%] in HO and 9% [2006=9%] in UH. Diabetics represented 21% of all MPS patients in 2007. Data of 215 institutions which participated all from 2005 to 2007 showed an increase in MPS of 2.3% (PP +6.8%, HO -4.5%, UH -18.2%). The type of stress was pharmacological in 27% [2006 = 27%]; 67% adenosine (of these 25% with exercise), 31% dipyridamole (of these 55% with exercise), and 2% dobutamine. Gated SPECT was performed in 47% [2006 = 42%] of all rest and in 44% [2006 = 39%] of all stress MPS. 61% [2006 = 83%] of all institutions did not apply perfusion scores. 20% [2006 = 24%] of the institutions reported changes in the use of MPS by competing methods. Conclusion: There is a small increase of MPS between 2005 and 2007 despite competing methods. Gated SPECT has experienced more acceptance, but is still underrepresented. As compared to the European average and general standards of MPS a considerable backlog accounts to pharmacological stress tests, gated SPECT and perfusion scores. (orig.)

  12. Prevention of subsequent exercise-induced periinfarct ischemia by emergency coronary angioplasty in acute myocardial infarction: comparison with intracoronary streptokinase

    International Nuclear Information System (INIS)

    Fung, A.Y.; Lai, P.; Juni, J.E.; Bourdillon, P.D.; Walton, J.A. Jr.; Laufer, N.; Buda, A.J.; Pitt, B.; O'Neill, W.W.

    1986-01-01

    To compare the efficacy of emergency percutaneous transluminal coronary angioplasty and intracoronary streptokinase in preventing exercise-induced periinfarct ischemia, 28 patients presenting within 12 hours of the onset of symptoms of acute myocardial infarction were prospectively randomized. Of these, 14 patients were treated with emergency angioplasty and 14 patients received intracoronary streptokinase. Recatheterization and submaximal exercise thallium-201 single photon emission computed tomography were performed before hospital discharge. Periinfarct ischemia was defined as a reversible thallium defect adjacent to a fixed defect assessed qualitatively. Successful reperfusion was achieved in 86% of patients treated with emergency angioplasty and 86% of patients treated with intracoronary streptokinase (p = NS). Residual stenosis of the infarct-related coronary artery shown at predischarge angiography was 43.8 +/- 31.4% for the angioplasty group and 75.0 +/- 15.6% for the streptokinase group (p less than 0.05). Of the angioplasty group, 9% developed exercise-induced periinfarct ischemia compared with 60% of the streptokinase group (p less than 0.05). Thus, patients with acute myocardial infarction treated with emergency angioplasty had significantly less severe residual coronary stenosis and exercise-induced periinfarct ischemia than did those treated with intracoronary streptokinase. These results suggest further application of coronary angioplasty in the management of acute myocardial infarction

  13. Clinical significance of stress-induced ST segment changes in patients with previous myocardial infarction

    International Nuclear Information System (INIS)

    Futagami, Yasuo; Hamada, Masayuki; Makino, Katsutoshi; Ichikawa, Takehiko; Konishi, Tokuji

    1984-01-01

    To explain the clinical significance of stress(st)-induced ST-segment (ST) changes postinfarction, 93 patients with previous myocardial infarction (MI) were performed st- 201 Tl myocardial single photon emission computed tomography (SPECT) and compared ST changes with SPECT, coronary arteriographic and left ventriculographic findings. 30 out of 93 cases (32%) had ST depression, 20 (21.5%) had ST elevation, 9 (10%) had both ST depression and elevation and remaining 34 (36.5 %) had no significant ST changes. In single vessel disease, ST depression were noted in 29% (12/42), while in multivessel disease, 53% (27/51). 35 out of 39 cases (90%) with ST depression had transient perfusion defect but no apparent relation was noted between location of ST depression on ECG and region of transient perfusion defect in SPECT. All of 28 cases with ST elevation were noted in anterior MI cases, and 26 out of these showed severe LV wall motion abnormality in contrast left ventriculography and broad anterior permanent defect in SPECT. Only 15 cases (54%) showed slight redistribution. Thus, we conclude that in patients with previous MI, st-induced ST depression seems to reflect myocardial ischemia and ST elevation possibly related abnormal LV wall motion. (author)

  14. Evaluation of myocardial abnormalities in collagen diseases by thallium-201 myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamano, Shigeru; Kagoshima, Tadashi; Sugihara, Kiyotaka (Nara Medical Univ., Kashihara (Japan)) (and others)

    1993-12-01

    This study was performed to evaluate myocardial abnormalities in patients with collagen diseases by exercise and rest thallium-201 myocardial scintigrams. A total of 65 patients without ischemic ECG changes, consisting of 18 with systemic lupus erythematosus (SLE), 18 with polymyositis (PM), 8 with progressive systemic sclerosis (PSS), and 21 with Sjoegren's syndrome (SjS), was enrolled in this study. Reversible exercise-induced defects scintigraphically suggesting myocardial ischemia were noted in 8 cases of SLE, 4 cases of PM, 4 cases of PSS, and 3 cases of SjS. Nineteen patients had exercise-induced defects and underwent cardiac catheterization, 8 of whom had normal coronary angiograms. Fixed hypoperfusion areas were observed in one case of SLE, 6 cases of PM and 3 cases of SjS. Rest thallium-201 myocardial scintigram disclosed hypoperfusion areas which were not induced by exercise in 2 cases of SLE, 3 cases of PM, one case of PSS and 5 cases of SjS. Echocardiogram showed no significant differences in ejection fraction and % fractional shortening between the disease groups and healthy control group. These findings suggest that patients with collagen diseases have abnormalities of coronary circulation at the level of the intramural vasculature before cardiac function impairment, myocardial fibrosis and functional abnormalities at the cell membrane. (author).

  15. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    International Nuclear Information System (INIS)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M.

    1989-01-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction

  16. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  17. Human Cardiac 31P-MR Spectroscopy at 3 Tesla Cannot Detect Failing Myocardial Energy Homeostasis during Exercise

    Directory of Open Access Journals (Sweden)

    Adrianus J. Bakermans

    2017-11-01

    Full Text Available Phosphorus-31 magnetic resonance spectroscopy (31P-MRS is a unique non-invasive imaging modality for probing in vivo high-energy phosphate metabolism in the human heart. We investigated whether current 31P-MRS methodology would allow for clinical applications to detect exercise-induced changes in (patho-physiological myocardial energy metabolism. Hereto, measurement variability and repeatability of three commonly used localized 31P-MRS methods [3D image-selected in vivo spectroscopy (ISIS and 1D ISIS with 1D chemical shift imaging (CSI oriented either perpendicular or parallel to the surface coil] to quantify the myocardial phosphocreatine (PCr to adenosine triphosphate (ATP ratio in healthy humans (n = 8 at rest were determined on a clinical 3 Tesla MR system. Numerical simulations of myocardial energy homeostasis in response to increased cardiac work rates were performed using a biophysical model of myocardial oxidative metabolism. Hypertrophic cardiomyopathy was modeled by either inefficient sarcomere ATP utilization or decreased mitochondrial ATP synthesis. The effect of creatine depletion on myocardial energy homeostasis was explored for both conditions. The mean in vivo myocardial PCr/ATP ratio measured with 3D ISIS was 1.57 ± 0.17 with a large repeatability coefficient of 40.4%. For 1D CSI in a 1D ISIS-selected slice perpendicular to the surface coil, the PCr/ATP ratio was 2.78 ± 0.50 (repeatability 42.5%. With 1D CSI in a 1D ISIS-selected slice parallel to the surface coil, the PCr/ATP ratio was 1.70 ± 0.56 (repeatability 43.7%. The model predicted a PCr/ATP ratio reduction of only 10% at the maximal cardiac work rate in normal myocardium. Hypertrophic cardiomyopathy led to lower PCr/ATP ratios for high cardiac work rates, which was exacerbated by creatine depletion. Simulations illustrated that when conducting cardiac 31P-MRS exercise stress testing with large measurement error margins, results obtained under pathophysiologic

  18. Human Cardiac 31P-MR Spectroscopy at 3 Tesla Cannot Detect Failing Myocardial Energy Homeostasis during Exercise

    Science.gov (United States)

    Bakermans, Adrianus J.; Bazil, Jason N.; Nederveen, Aart J.; Strijkers, Gustav J.; Boekholdt, S. Matthijs; Beard, Daniel A.; Jeneson, Jeroen A. L.

    2017-01-01

    Phosphorus-31 magnetic resonance spectroscopy (31P-MRS) is a unique non-invasive imaging modality for probing in vivo high-energy phosphate metabolism in the human heart. We investigated whether current 31P-MRS methodology would allow for clinical applications to detect exercise-induced changes in (patho-)physiological myocardial energy metabolism. Hereto, measurement variability and repeatability of three commonly used localized 31P-MRS methods [3D image-selected in vivo spectroscopy (ISIS) and 1D ISIS with 1D chemical shift imaging (CSI) oriented either perpendicular or parallel to the surface coil] to quantify the myocardial phosphocreatine (PCr) to adenosine triphosphate (ATP) ratio in healthy humans (n = 8) at rest were determined on a clinical 3 Tesla MR system. Numerical simulations of myocardial energy homeostasis in response to increased cardiac work rates were performed using a biophysical model of myocardial oxidative metabolism. Hypertrophic cardiomyopathy was modeled by either inefficient sarcomere ATP utilization or decreased mitochondrial ATP synthesis. The effect of creatine depletion on myocardial energy homeostasis was explored for both conditions. The mean in vivo myocardial PCr/ATP ratio measured with 3D ISIS was 1.57 ± 0.17 with a large repeatability coefficient of 40.4%. For 1D CSI in a 1D ISIS-selected slice perpendicular to the surface coil, the PCr/ATP ratio was 2.78 ± 0.50 (repeatability 42.5%). With 1D CSI in a 1D ISIS-selected slice parallel to the surface coil, the PCr/ATP ratio was 1.70 ± 0.56 (repeatability 43.7%). The model predicted a PCr/ATP ratio reduction of only 10% at the maximal cardiac work rate in normal myocardium. Hypertrophic cardiomyopathy led to lower PCr/ATP ratios for high cardiac work rates, which was exacerbated by creatine depletion. Simulations illustrated that when conducting cardiac 31P-MRS exercise stress testing with large measurement error margins, results obtained under pathophysiologic conditions may

  19. Evaluation of diagnostic efficiency of intelligence program for automatic diagnosis of circumferential profiles of myocardial short axial SPECT

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Tada, Akira; Nakajima, Kenichi; Taki, Junichi; Kojima, Kazuhiko.

    1984-01-01

    Quantitative diagnosis using circumferential profile (CFP) is widely employed for Tl-201 myocardial imaging. However, its diagnostic efficiency is susceptible to the number and composition of the confirmed normal (CN) group. Intelligence program for CFP data file and automatic diagnosis (CAD), which was previously developed by us, was modified for creating universal data file (d-base) and evaluated its diagnostic efficiency for myocardial short axial images according to the number of CNs. CAD consists of following 3 major functions: (1) CFP data filing to d-base, (2) modification and correction of file data, and (3) automatic diagnosis of CFP. When function (1) or (2) is completed, new diagnostic criteria (mean-2 sd) are generated automatically using CN data in the d-base at that time. Because of this function, diagnostic criteria are changeable according to the number of CNs. Sensitivity (TP) and specificity (TN) of CAD program for Tl-201 7-pinhole images of 16 normals and 17 ischemic heart diseases (IHDs) were 100%, 44% (CN = 4), 88%, 94% (CN = 8 or 16) and 88%, 100% (CN = 12), respectively. Diagnostic efficiency reached plateau in more than 8 CNs. Although number of patients were limited (8 CNs and 6 IHDs), results of CAD for short axial SPECT showed consistent tendency with 7-pinhole images. In conclusion, intelligence program is necessary for automatic diagnosis using quantitative criteria under the clinical condition of daily increasing informations. Automatic diagnosis of CFP using CAD program is simple, effective and useful for interpretation of Tl-201 myocardial short axial images. CAD program is applicable to any quantitative distribution study using CFPs. (author)

  20. Area at risk can be assessed by iodine-123-meta-iodobenzylguanidine single-photon emission computed tomography after myocardial infarction: a prospective study.

    Science.gov (United States)

    Hedon, Christophe; Huet, Fabien; Ben Bouallegue, Fayçal; Vernhet, Hélène; Macia, Jean-Christophe; Cung, Thien-Tri; Leclercq, Florence; Cade, Stéphane; Cransac, Frédéric; Lattuca, Benoit; Vandenberghe, D'Arcy; Bourdon, Aurélie; Benkiran, Meriem; Vauchot, Fabien; Gervasoni, Richard; D'estanque, Emmanuel; Mariano-Goulart, Denis; Roubille, François

    2018-02-01

    Myocardial salvage is an important surrogate endpoint to estimate the impact of treatments in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to evaluate the correlation between cardiac sympathetic denervation area assessed by single-photon emission computed tomography (SPECT) using iodine-123-meta-iodobenzylguanidine (I-MIBG) and myocardial area at risk (AAR) assessed by cardiac magnetic resonance (CMR) (gold standard). A total of 35 postprimary reperfusion STEMI patients were enrolled prospectively to undergo SPECT using I-MIBG (evaluates cardiac sympathetic denervation) and thallium-201 (evaluates myocardial necrosis), and to undergo CMR imaging using T2-weighted spin-echo turbo inversion recovery for AAR and postgadolinium T1-weighted phase sensitive inversion recovery for scar assessment. I-MIBG imaging showed a wider denervated area (51.1±16.0% of left ventricular area) in comparison with the necrosis area on thallium-201 imaging (16.1±14.4% of left ventricular area, Parea (P=0.23) and was adequately correlated (R=0.56, P=0.0002). Myocardial salvage evaluated by SPECT imaging (mismatch denervated but viable myocardium) was significantly higher than by CMR (P=0.02). In patients with STEMI, I-MIBG SPECT, assessing cardiac sympathetic denervation may precisely evaluate the AAR, providing an alternative to CMR for AAR assessment.