WorldWideScience

Sample records for exercise radionuclide ventriculography

  1. Radionuclide exercise ventriculography and levels of workload

    International Nuclear Information System (INIS)

    Wynchank, S.

    1982-01-01

    The wealth of useful information made available from the utilization of radionuclide cardiological investigations by non-invasive means is outlined and reasons for investigating results obtained under conditions of increased heart workload are explained. The lack of an accepted protocol for the determination of exercise levels is noted. A format for obtaining increasing heart loads dependent on increasing pulse rate is offered, with justification. Exercise radionuclide ventriculography examinations can be conducted which are simple, reproducible and allow appropriate levels of stress in patients who can benefit from such investigations

  2. Factor analysis for exercise stress radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hirota, Kazuyoshi; Yasuda, Mitsutaka; Oku, Hisao; Ikuno, Yoshiyasu; Takeuchi, Kazuhide; Takeda, Tadanao; Ochi, Hironobu

    1987-01-01

    Using factor analysis, a new image processing in exercise stress radionuclide ventriculography, changes in factors associated with exercise were evaluated in 14 patients with angina pectoris or old myocardial infarction. The patients were imaged in the left anterior oblique projection, and three factor images were presented on a color coded scale. Abnormal factors (AF) were observed in 6 patients before exercise, 13 during exercise, and 4 after exercise. In 7 patients, the occurrence of AF was associated with exercise. Five of them became free from AF after exercise. Three patients showing AF before exercise had aggravation of AF during exercise. Overall, the occurrence or aggravation of AF was associated with exercise in ten (71 %) of the patients. The other three patients, however, had disappearance of AF during exercise. In the last patient, none of the AF was observed throughout the study. In view of a high incidence of AF associated with exercise, the factor analysis may have the potential in evaluating cardiac reverse from the viewpoint of left ventricular wall motion abnormality. (Namekawa, K.)

  3. Detection of coronary artery disease by exercise radionuclide ventriculography, (1)

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Saito, Muneyasu; Uehara, Toshiisa; Kozuka, Takahiro

    1982-01-01

    In order to assess the detection of coronary artery disease (CAD) and LV functional reserve, exercise radionuclide ventriculography (ERV) were performed in 80 patients who underwent selective cardiac catneterization for evaluation of chest pain syndrome. 70 patients had CAD (30 patients with angina pectoris and 40 patients with myocardial infarction) and 10 did not. In this study, to obtain accurate data by ERV, its practical consideration were metioned. Radionuclide cardioangiography with sup(99m)Tc-invivo RBC labelling were performed using an Anger camera attached with high-sense collimator and on-line minicomputer system. For data aquisition, multi-gated method were used, especially during exercise, list mode collection was suitable for ERV because of variable R-R intervals. Patient stability was performed with an adjustable shoulder support and hand grip, ECG monitoring system by carbon electrolode was used to obtain during exercise. Exercise protocal was graded bicycle ergometer in supine position. As the results, in the patients of CAD, changes of LVEF from rest to exercise were under 5%, while in normal patients, LVEF increased over 5% in all patients. In 30 patients with angina pectoris, the ERV was abnormal in 25 for a sensitivity of 83.3% and specificity of 100%. The ERV were thought to be superior than stress ECG for the detection of CAD. In conclusion, with increasing clinical application, the use of ERV is rapidly becoming wider-spread but the excellent results were thought to depend upon the careful attention to equipment and exercise procedure. (author)

  4. Exercise radionuclide ventriculography to detect restenosis following coronary angioplasty

    International Nuclear Information System (INIS)

    De Puey, E.G.; Leatherman, L.L.; Dear, W.E.; Leachman, R.D.; Massin, E.K.; Mathur, V.S.; Burdine, J.A.

    1984-01-01

    Forty one patients (pts) underwent semiupright exercise gated radionuclide ventriculography (EGRNV) before, within 3 d after single vessel transluminal coronary angioplasty (TCA), and 4 to 12 mos later, at which time follow-up cardiac catheterization was also performed. Prior to TCA 76% of pts had abnormal EGRNV, as defined by a failure to increase ejection fraction (EF) by 5 points or the development of a new regional wall motion abnormality. Stenosis was reduced from 90 +- 7% to 18 +- 17%. Early after TCA, exercise duration and maximum double product increased (p's 20% but <50%; Group III (n=8): ≥ 50%] Pts with abnormal EGRNV early after TCA were demonstrated to have a greater percent increase in stenosis at late follow-up than pts with normal EGRNV (41 +- 30% vs 19 +- 25%, p<.001). Early after TCA EGRNV was abnormal in 5% of Group I pts vs 75% in Group III (p<.01), and EF increased to a greater degree during exercise in Group I pts (+11.3 +- 7.5 vs +3.5 +- 6.5 points, p<.01). At 4-12 mos EGRNV was abnormal in 27% of Group I vs 88% of Group III (p<.01), and during exercise EF increased in Group I pts (+11.8 +- 7.8 points) but decreased in Group III (-1.9 +- 8.7 points) (p<.0005). The accuracy of abnormal EGRNV in predicting ≥ 50% restenosis was 73% early post-TCA and 77% at 4-12 mos. The authors conclude that EGRNV is a valuable test to verify the success of TCA and to detect subsequent restenosis

  5. Importance of adequate exercise in the detection of coronary heart disease by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Brady, T.J.; Thrall, J.H.; Lo, K.; Pitt, B.

    1980-01-01

    Rest and exercise radionuclide ventriculograms were obtained on 77 symptomatic patients without prior documented coronary artery disease (CAD). Coronary artery disease was present by angiograms in 48. Radionuclide ventriculography (RNV) was abnormal in 41 patients (overall sensitivity 85%). In 29 patients with normal coronary arteries, RNV was normal in 24 (specificity 83%). To determine if the exercise level affects sensitivity, the studies were graded for adequacy of exercise. It was considered adequate if patients developed (a) chest pain, or (b) ST segment depression of at least 1 mm, or (c) if they achieved a pressure rate product greater than 250. Among the 48 patients with coronary artery disease, 35 achieved adequate exercise. Thirty-three had an abnormal RNV (sensitivity 94%). In 13 patients who failed to achieve adequate exercise, RNV was abnormal in eight (sensitivity of only 62%). Some patients with coronary artery disease may have a normal ventricular response at inadequate levels of stress

  6. Segmental wall-motion analysis in the right anterior oblique projection: comparison of exercise equilibrium radionuclide ventriculography and exercise contrast ventriculography

    International Nuclear Information System (INIS)

    Brady, T.J.; Thrall, J.H.; Keyes, J.W. Jr.; Brymer, J.F.; Walton, J.A.; Pitt, B.

    1980-01-01

    Thirty-nine patients with known or suspected coronary artery disease were studied at rest and during supine bicycle exercise with radionuclide and contrast left ventriculography. Analysis of regional wall motion was made by visual evaluation of the five standard 30 0 right anterior oblique (RAO) wall segments in the contrast images and the corresponding 10 0 RAO radionuclide segments. The radionuclide studies were evaluated independently by three observers using a five-point grading system. The interobserver wall-motion grading agreed completely in more than 80% of segments at rest and exercise, and agreed within one wall-motion grade in more than 95% of segments. The comparison of wall-motion grades between radionuclide and contrast ventriculograms showed complete agreement in 86% of segments at rest and in 78% during exercise, and agreement within one wall-motion grade in 97% of rest and 96% of exercise segments. Visual evaluation of 10 0 RAO rest and exercise radionuclide ventriculograms compares favorably with rest and exercise 30 0 RAO contrast ventriculograms and demonstrates satisfactory interobserver agreement

  7. Possibilities of exercise radionuclide ventriculography carried out in equilibrium in the detection of ischaemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Csernay, L.; Mester, J.; Edes, I.; Pavics, L.; Gruber, N.; Szasz, K.; Csanady, M.

    1985-08-04

    Authors give account of the initiation of the exercise radionuclide ventriculography and of their diagnostic experiences. In 33 control persons and 20 patients with coronary heart disease verified with coronarography, the left ventricular ejection fraction, the wall motion and the systolic and diastolic volume of the left ventricle were examined at rest and during exercise. A decrease or an increase of not more than 5% of ejection fraction, the exercise induced wall motion abnormalities or an increase of resting wall motion disorder were interpreted as an index of underlying significant coronary stenosis. A sensitivity of 90% and a specificity of 88% of the method were found. Upon the results, which are in good agreement with literary data, the initiation of the method in nuclear medical laboratories equipped with camera-computer system is proposed

  8. Possibilities of exercise radionuclide ventriculography carried out in equilibrium in the detection of ischaemic heart disease

    International Nuclear Information System (INIS)

    Csernay, Laszlo; Mester, Janos; Edes, Istvan; Pavics, Laszlo; Gruber, Noemi; Szasz, Karoly; Csanady, Miklos

    1985-01-01

    Authors give account of the initiation of the exercise radionuclide ventriculography and of their diagnostic experiences. In 33 control persons and 20 patients with coronary heart disease verified with coronarography, the left ventricular ejection fraction, the wall motion and the systolic and diastolic volume of the left ventricle were examined at rest and during exercise. A decrease or an increase of not more than 5% of ejection fraction, the exercise induced wall motion abnormalities or an increase of resting wall motion disorder were interpreted as an index of underlying significant coronary stenosis. A sensitivity of 90% and a specificity of 88% of the method were found. Upon the results, which are in good agreement with literary data, the initiation of the method in nuclear medical laboratories equipped with camera-computer system is proposed. (author)

  9. Rest and exercise radionuclide ventriculography in the ambulatory monitoring of patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Raichlen, J.S.; Brest, A.N.

    1988-01-01

    Radionuclide angiography serves as a valuable adjunct in the noninvasive evaluation and monitoring of patients with valvular heart disease. Although estimations of regurgitant fractions and the differences between left and right ventricular stroke volumes can be made, the limitations of the techniques do not enable adequate quantitation of the severity of valvular insufficiency to warrant routine use in ambulatory management. The importance of radionuclide ventriculography, however, lies in its ability to examine global ventricular function both at rest and with exercise, thus enabling assessment of the functional reserve of the left and right ventricles. Such data are of considerable value in determining the need for invasive evaluation and the timing of valve replacement in patients with valvular heart disease. 41 references.

  10. Rest and exercise radionuclide ventriculography in the ambulatory monitoring of patients with valvular heart disease

    International Nuclear Information System (INIS)

    Raichlen, J.S.; Brest, A.N.

    1988-01-01

    Radionuclide angiography serves as a valuable adjunct in the noninvasive evaluation and monitoring of patients with valvular heart disease. Although estimations of regurgitant fractions and the differences between left and right ventricular stroke volumes can be made, the limitations of the techniques do not enable adequate quantitation of the severity of valvular insufficiency to warrant routine use in ambulatory management. The importance of radionuclide ventriculography, however, lies in its ability to examine global ventricular function both at rest and with exercise, thus enabling assessment of the functional reserve of the left and right ventricles. Such data are of considerable value in determining the need for invasive evaluation and the timing of valve replacement in patients with valvular heart disease. 41 references

  11. Automated system for ST segment and arrhythmia analysis in exercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hsia, P.W.; Jenkins, J.M.; Shimoni, Y.; Gage, K.P.; Santinga, J.T.; Pitt, B.

    1986-01-01

    A computer-based system for interpretation of the electrocardiogram (ECG) in the diagnosis of arrhythmia and ST segment abnormality in an exercise system is presented. The system was designed for inclusion in a gamma camera so the ECG diagnosis could be combined with the diagnostic capability of radionuclide ventriculography. Digitized data are analyzed in a beat-by-beat mode and a contextual diagnosis of underlying rhythm is provided. Each beat is assigned a beat code based on a combination of waveform analysis and RR interval measurement. The waveform analysis employs a new correlation coefficient formula which corrects for baseline wander. Selective signal averaging, in which only normal beats are included, is done for an improved signal-to-noise ratio prior to ST segment analysis. Template generation, R wave detection, QRS window size, baseline correction, and continuous updating of heart rate have all been automated. ST level and slope measurements are computed on signal-averaged data. Arrhythmia analysis of 13 passages of abnormal rhythm by computer was found to be correct in 98.4 percent of all beats. 25 passages of exercise data, 1-5 min in length, were evaluated by the cardiologist and found to be in agreement in 95.8 percent in measurements of ST level and 91.7 percent in measurements of ST slope

  12. The value of exercise radionuclide ventriculography in risk stratification after coronary arterial bypass grafting

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Goel, I.P.; Mundth, E.D.; Kane, S.; Schenk, C.

    1985-01-01

    Cardiac events after coronary artery bypass surgery (CABG) may be related to left ventricular (LV) function, residual coronary artery diseases (CAD), graft occlusion, and progression of CAD. This study examined the value of rest and exercise (EX) radionuclide ventriculography (RNV) done 3-6 mos after CABG in risk stratification in 212 pts. There were 185 men and 27 women, aged 57 +- 8 years (mean +- SD). During a followup period of up to 4 years, (15 +- 10 months), there were 23 cardiac events; 13 pts died of cardiac causes and 20 had non-fatal acute myocardial infarctions. The pts with and without events did not differ in: clinical presentation after CABG (most were asymptomatic), medications and ECG findings at rest and EX. The pts with events had lower EX systolic blood pressure (p < 0.01); resting LV ejection fraction (EF) (p = 0.002), and EX EF (40 +- 18% vs 54 +- 16%, p = 0.002). The change in EF (rest to EX) was not significantly different (l.6 +- 8.2%, vs 2.1 +- 9.2%). Survival analysis (Cox model) identified the EX EF as the best predictor of death and total events (X/sup 2/ = 4.3 and 2.4, p = 0.04 and 0.07 respectively). Actuarial life table analysis showed that the risk increased as the EX EF decreased when pts were grouped into EX EF ≥ 50, 30-49, and <30%, (p < 0.001, Mantel-Cox). Thus, EX RNA is useful in risk stratification after CABG. The EX LVEF is an important descriptor that categorizes pts into different risks groups. The pts at high risk probably require more aggressive followup and continued medical therapy

  13. Can isosorbide dinitrate (ISDN) prevent myocardial ischemia during exercise in patients with coronary artery disease; An assessment with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Koyama, Takao; Aoki, Toshikazu; Okamoto, Shinya; Setsuda, Morimichi; Futagami, Yasuo; Nakano, Takeshi (Mie Univ., Tsu (Japan). School of Medicine)

    1989-12-01

    The effects of sublingual isosorbide dinitrate (ISDN) on left ventricular function during exercise were evaluated in 8 patients with coronary artery disease. ECG gated multistage exercise radionuclide ventriculography (RNV) was performed to assess the global and regional left ventricular function before and after sublingual ISND. Chest pain during exercise was observed in six patients (75%) during exercise but subsided negative ISDN. Left ventricular ejection fraction (LVEF) during stress did not show improved significant change during exercise (from 64.4 {plus minus} 8.7% to 64.6 {plus minus} 8.3%) but increased significantly from 66.0 {plus minus} 6.3% to 69.9 {plus minus} 8.6% after ISDN. Left ventricular end-systolic volume increased during exercise from 56.9 {plus minus} 19.6 ml to 68.0 {plus minus} 15.9 ml, but the increase was suppressed (from 49.1 {plus minus} 11.0 ml to 44.5 {plus minus} 15.5 ml) after ISDN. ISDN prevented not only cardiac symptoms nor ECG changes but also improved abnormal left ventricular function during exercise. (author).

  14. Comparison of exercise stress testing with dobutamine stress echocardiography and radionuclide ventriculography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Ozdemir, K.; Kisacik, H.L.; Oguzhan, A.

    1999-01-01

    Dobutamine stress echocardiography, Tc-99m radionuclide ventriculography (RNVG), and exercise stress testing were performed prospectively in 63 patients with suspected coronary artery disease to compare the values of exercise testing, dobutamine stress echocardiography and RNVG in the non-invasive diagnosis of coronary artery disease. The sensitivities of dobutamine stress echocardiography and RNVG were found to be higher than that of exercise testing (93-62%, p 0.05). There were no differences between the sensitivities of the three techniques in multiple vessel disease (p>0.05). The specificities of dobutamine stress echocardiography and RNVG were higher than that of exercise testing (for both of the tests 86-62%, p 0.05). The results of dobutamine stress echocardiography RNVG were concordant with each other in 46 patients (76%, kappa=65%) in sectional analysis. Dobutamine stress echocardiography and RNVG tests were comparable with each other in 85% of the 189 segments (kappa=64%). The expected 5% decrease at peak doses of dobutamine was not detected in stress echocardiography in 25 patients and in RNVG in 26 of the patients. Dobutamine stress echocardiography and RNVG are superior to exercise testing in the diagnosis of single vessel disease and there is no significant difference between the two techniques. When the ejection fraction is considered in dobutamine stress echocardiography and RNVG, it does not make an additional contribution to the diagnosis of coronary artery disease. (author)

  15. Application of radionuclide ventriculography to cardiac screening

    International Nuclear Information System (INIS)

    Lindsay, J. Jr.; Milner, M.R.; Chandeysson, P.L.; Rodman, D.J.; Okin, P.M.; Goldstein, S.A.

    1989-01-01

    Screening asymptomatic individuals for latent coronary disease often requires sequential testing because exercise electrocardiography typically produces more false positive than true positive results in a population with a low prevalence of coronary disease. Cardiac scintigraphy is a technique that may be employed as a confirmatory test in lieu of coronary arteriography to further evaluate the significance of a positive exercise electrocardiogram. Radionuclide ventriculography was employed in 98 asymptomatic individuals who were considered to be at moderate risk of heart disease after risk factor analysis and exercise electrocardiography. Seventeen (17%) patients had an abnormal study and underwent cardiac catheterization. Seven had coronary artery disease, two had cardiomyopathy, and eight were normal. Eighty-one (83%) patients had a normal study. Because the sensitivity of radionuclide ventriculography is 63-80%, it was postulated that 2 to 5 individuals with disease were missed. Thus, from a population with an 11-14% prevalence of disease, two subsets were identified. A large subset in which a prevalence of 2-6% could be estimated was separated from a much smaller one in which a prevalence of approximately 50% was demonstrated

  16. Exercise tolerance in mitral stenosis and chronic obstructive pulmonary disease. Evaluation by anaerobic threshold and radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Uenami, Atsushi; Mizuno, Toshikazu; Chiba, Hiroshi; Ohno, Masanori; Wakino, Kouichi; Sawada, Yoshihiro; Ohno, Joichi; Kume, Kiyoshi

    1986-06-01

    Serial radionuclide ventriculography was performed using a newly developed ''real-time'' system, and left ventricular ejection fraction (LVEF), right ventricular ejection fraction (RVEF), stroke volume (SV), and cardiac output (CO) were measured during graded supine exercise in five patients with mitral stenosis (MS), in five patients with chronic obstructive pulmonary disease (COPD) and in five healthy subjects. Simultaneous pulmonary gas exchange analysis permitted determining the anaerobic threshold, which is the point during incremental exercise when lactate begins to accumulate in the blood. LVEF at the anaerobic threshold was not significantly changed in any patient groups and in healthy subjects, but RVEF at the anaerobic threshold was lower in COPD and MS patients as compared with healthy subjects. In MS, SV during exercise was reduced at the anaerobic threshold, but not in COPD or in healthy subjects. In conclusion, reduced working capacity is related to decreased RVEF in both COPD and MS, but the inhibited increase in CO during exercise is also important for the working capacity in MS.

  17. Left ventricular performance at rest and during peak exercise in never-treated hypertensive female - an assessment with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Topuzovic, N.; Karner, I.; Rusic, A.; Krstonosic, B.

    2002-01-01

    Aim: The aim of this study was to investigate left ventricular performance and exercise tolerance in never-treated female hypertensive patients. Materials and Methods: Seventeen female patients with newly established, uncomplicated essential hypertension (aged 25 to 57 years) were evaluated with rest-stress radionuclide gated ventriculography, and were compared to 23 age-matched normotensive female volunteers. Results: Mean blood pressure was significantly higher in patients at rest and during exercise than in controls (121±13 vs. 89±7 mm Hg, and 143±11 vs. 122±9 mm Hg, respectively, p 2 , respectively, p<0.01), while ESV was similar in both groups. Ejection fraction (EF) at rest and stress did not differ significantly (54±10 vs. 55±8%, and 70±10 vs. 66±8%, respectively), but % rise in EF during exercise was significantly higher in patients. At rest and during exercise, there were no significant difference in peak ejection rate (PER) and time to PER (TPER) between patients and controls. Patients had similar peak filling rate (PFR) at rest (2.88±0.79 vs. 2.76±0.76 EDV/s) and during exercise (5.85±1.86 vs. 6.21±1.97 EDV/s), in addition to nonsignificant difference in time to PFR (at rest 143±62 vs. 146±42 ms at rest, and 97±20 vs. 91±19 ms during exercise). Conclusion: Female patients with newly diagnosed, never-treated hypertension have preserved maximal exercise performance, systolic function and diastolic function, but they have significant enlargement of EDV and elevated cardiac output during exercise

  18. Can the diagnostic accuracy of radionuclide ventriculography during exercise be improved by means of a step-up loading procedure?

    International Nuclear Information System (INIS)

    Ruegenberg, T.

    1985-01-01

    34 patients (31 of whom were coronary heart disease sufferers as proven by angiography) and further 3 patients failing to show symptoms of this disorder were subjected to radionuclide ventriculography carried out with the aid of 99m Tc-labelled erythrocytes in such a way that examinations at rest were directly followed by maximum loading tests. In a second series of examinations a step-up procedure was adopted where initial recordings at rest were followed by preliminary exercise tests using only 25% of the maximum load. The parameters chosen to evaluate the results were heart rate, ejection fraction, maximum velocity of changes in volume, endsystolic and enddiastolic volumes (ESV and EDV) as well as cardiac output. In 23 patients the preliminary exercise test revealed an insufficient increase or even decrease of the ejection fraction that was associated with delayed volume changes, increases in ESV and EDV as well as reductions in cardiac output and in 21 patients it became evident during those examinations that the onset of stenocardiac complaints was preceded by markedly pronounced function disorders in the left ventricle. It was concluded from these findings that the step-up procedure followed here may in some patients provide additional information on the level of myocardial performance. It can thus be assumed to contribute considerably to higher diagnostic accuracy, although it requires no more time than conventional exercise tests and is not associated with additional radiation exposure. (TRV) [de

  19. How to accurately assess the clinical value of isometric exercise radionuclide ventriculography in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Yang Shunfang; Zhu Huiping; Zeng Jun; Xie Wenhui; Yu Zhichang

    2001-01-01

    To assess the influence of isometric handgrip exercise on left ventricular function by radionuclide ventriculography in patients with coronary artery disease (CAD). Using gated equilibrium radionuclide ventriculography, parameters of left ventricular function were analyzed at rest and during 30% sustained handgrip (HNG) for 5 - 10 minuets in 8 normal control subjects and 38 consecutive CAD patients. All investigated subjects were also performed coronary arteriography within 2 weeks. Results showed that at rest, left ventricular ejection fraction (LVEF), peak filling rate (PFR), end-diastolic volume (EDV), end-systolic volume (ESV) and heart rate (HR) were reduced in one-vessel, two-vessel and three-vessel of stenosis patient group (53.67 +- 5.0)%, (52.47 +- 8.26)%, (52.81 +- 8.89)%; 2.87 +- 0.29, 2.71 +- 0.88, 3.07 +- 0.71 end-diastolic volume per second (EDV/s); 1.36 +- 0.05, 1.34 +- 0.06, 1.34 +- 0.06; 0.62 +-0.06, 0.66 +- 0.06, 0.65 +- 0.1; 69.67 +- 8.14, 72.85 +- 10.5, 76.56 +- 18.04 (min -1 ), respectively, as compared with controls (57 +- 10.45)%, p = NS; 2.94 +- 0.44 (EDV/s), p = NS; 1.38 +- 0.15, p = NS; 0.59 +- 0.11, p = NS; 72.88 +- 8.25 (min -1 ), p = NS, respectively. During HNG exercise using both hands, the indexes were reduced in CAD patients (54.44 +- 5.66)%, (48.84 +- 8.70)%, (45.25 +- 8.69)%; 2.75 +- 0.39, 2.50 +- 0.68, 2.22 +- 0.58 (EDV/s); 1.36 +- 0.05, 1.31 +- 0.06, 1.26 +- 0.07; 0.61 +- 0.07, 0.69 +- 0.06, 0.71 +- 0.09; 81.33 +- 8.92, 84.46 +- 14.29, 90.56 +- 26.54 (min -1 ), respectively, as compared with controls (59.38 +- 9.44)%, p = NS; -1 ), p = NS, respectively. The four protocols of CAD diagnosis were 1. LVEF <55% and ΔPFR < 0 EDV/s at rest (Δ value = during HNG value-rest value); 2. LVEF <55% during HNG and ΔPFR <0 EDV/s; 3. ΔLVEF <0% and ΔPFR <0 EDV/s; 4. ΔEF <0%. Their sensitivity, specificity and accuracy were 45%, 53%, 66%, 76%, 100%, 100%, 87.5%, 87.5%, 54%, 61%, 70%, 78%, respectively. The isomeric exercise radionuclide

  20. The significance of abnormal systolic blood pressure response during supine ergometer exercise and postexercise in ischemic heart disease, studied by exercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Ajisaka, Ryuichi; Watanabe, Shigeyuki; Masuoka, Takeshi

    1989-01-01

    Abnormal response to blood pressure (BP) during exercise and postexercise was examined in 169 patients with ischemic heart disease. The patients underwent supine ergometer exercise gated equilibrium radionuclide ventriculography and coronary arteriography. When BP during exercise did not increase by at least 11 mmHg or initially increased but later decreased by more than 10 mmHg, the BP response was defined as abnormal during exercise. A postexercise BP increase of more than 10 mmHg above the peak exercise BP was defined as abnormal during postexercise. Fifteen-one patients (30%) were classified as abnormal (group 1) and the other 118 as normal (group 2). Abnormal BP response fell into three types: (1a) exercise hypotension (n=11), (1b) postexercise hypertension (n=30), and (1c) exercise hypotension with postexercise hypertension (n=10). Both average exercise duration and peak heart rate were significantly lower in groups 1a, 1b, and 1c than group 2. Exercise ST-segment depression was more noticeable in groups 1b and 1c than group 2. However, there was no significant difference in the severitiy of exercise ST-segment depression between groups 1a and 2. A decline in ejection fraction occurred more frequently in groups 1b and 1c than group 2. Patients in groups 1a, 1b, and 1c had more extensive coronary artery disease than did patients in group 2. Medically managed patients having an abnormal BP response had a poorer prognosis than those with a normal BP response. An abnormal BP response during both supine exercise and postexercise was infrequent. The abnormal BP during exercise may be usually associated with impaired exercise tolerance and severe coronary artery disease; and that during postexercise may be closely associated with myocardial ischemia and global left ventricular dysfunction. Postexercise hypertension may be of the same value as exercise hypotension in predicting poor prognosis. (Namekawa, K)

  1. Atrial pacing as an alternative to supine exercise (SE) in radionuclide ventriculography (RNV)

    International Nuclear Information System (INIS)

    Le Grand, V.; Wells, S.; O'Neil, W.W.; Jenkins, J.; Gross, M.D.; Vogel, R.

    1984-01-01

    Stress RNV is at times of limited value as many patients cannot achieve a sufficient pressure rate product (PRP). Atrial pacing is a noninvasive alternative to SE by bicycle ergometry. A swallowable electrode attached to a flexible wire is positioned in a retroatrial position in the esophagus and when connected to a variable output stimulator, variable rate (120, 140, 160 beats/min) atrial pacing ventriculography (APV) can be performed. RNV is performed in the sitting position at rest and at each pacing stage. APV was compared to SE RNV in 4 patients with coronary artery disease (CAD) and 3 normal volunteers (N). Tolerance to APV was excellent with adequate pacing. All subjects reported a minor sensation of chest burning. No arrhythmias occurred. At maximal APV mean PRP was 174 +- 26. The diastolic volumes in APV fell in all patients. Systolic volumes fell in N but not in CAD to APV. A flat EF response to APV was seen in both N and CAD patients. APV is an alternative to SE RNV although PRP remains low. Volume changes in APV are different than in SE RNV and in the interpretation of the results of APV in CAD, changes in systolic and diastolic volumes may be more important than the response of EF

  2. The value of exercise radionuclide ventriculography in risk stratification in patients with known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Kane, S.; Schenk, C.

    1985-01-01

    This study examined the value of rest and exercise (EX) radionuclide ventriculography (RNV) in risk stratification in 392 pts with suspected or known coronary artery disease who were being evaluated for anginal symptoms. There were 289 men and 203 women, aged 55 +- 12 years (mean +- SD). There were 20 cardiac events in the followup period of up to 4 years (19 +- 10 months): 14 pts died of cardiac causes and 6 had non-fatal acute myocardial infarctions. The pts with and without events did not differ in age, clinical presentation, risk factors, and rest and EX ECGs. However, pts with events had lower EX systolic blood pressure (p < 0.02); lower EX duration; (5.5 +- 2.5 vs 7.6 +- 3.7 minutes, p < 0.0l), lower resting left ventricular (LV) ejection fraction (EF) (p = 0.001), and lower EX EF (35 +- 17% vs 56 +- 15%, p = 0.0001). The change in EF from rest to EX was not significantly different (-0.1 +- 6.1 vs 3 +- 9.9). Univariate survival analysis (Cox model) showed several descriptors related to prognosis: EX EF, rest EF, wall motion and EX duration. Multivariate analysis, however, identified the EX EF as the only significant predictor (X/sup 2/ = 19.9). None of the other variables added independent information to that provided by the EX EF. Actuarial lie table analysis showed that the risk increased as the EX EF decreased, when pts were grouped into those with EXEF ≥ 50%, 30-49%, and <30%., (p = 0.001, Mantel-Cox). Thus, the EX RNV is useful in risk stratification; the EX EF is the best descriptor that categorizes pts into different risk groups

  3. Computer analysis of the exercise electrocardiogram and control of radionuclide ventriculography: an optimal statistical decision model for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Hsia, P.W.E.

    1987-01-01

    A new automated technique for the diagnosis of coronary artery disease (CAD) by stress electrocardiography and radionuclide ventriculography (RNV) has been developed. The method employs digital signal processing of the electrocardiogram (ECG) for recognition of ischemic and arrhythmic events. On-line detection of abnormal beats is used for control image acquisition by the gamma camera resulting in improved image quality since only identical beats are included in the composite images of the cardiac cycle. A combined stress ECG analysis which measures ST changes indicative of ischemia, and radionuclide results, which reveal corresponding ejection fraction abnormalities yields greater sensitivity and specificity than either test alone. Digitized data from the electrocardiogram are analyzed in a beat-by-beat mode and a contextual diagnosis of underlying rhythm is given. Template generation, R wave detection, QRS window size, baseline correction, and continuous updating of heart rate are completely automated. A statistical model base on computerized ST segment measurements combined with radionuclide ventriculography data has been developed by using a logistic model with stepwise regression fitting. A previously acquired database of similar measurements was used for designing the model. The most significant parameters were found to be (1) ejection fraction of exercise RNV; (2) difference of ST level between exercise and resting test (stdif); and (3) ejection fraction difference between exercise and resting test. The new parameter stdif, not previously used in ECG interpretation, was found to be of great diagnostic significance

  4. Incremental value of clinical assessment, supine exercise electrocardiography, and biplane exercise radionuclide ventriculography in the prediction of coronary artery disease in men with chest pain

    International Nuclear Information System (INIS)

    Currie, P.J.; Kelly, M.J.; Harper, R.W.; Federman, J.; Kalff, V.; Anderson, S.T.; Pitt, A.

    1983-01-01

    The incremental value of clinical assessment, exercise electrocardiography (ECG) and biplane radionuclide ventriculography (RVG) in the prediction of coronary artery disease (CAD) was assessed in 105 men without myocardial infarction who were undergoing coronary angiography for investigation of chest pain. Independent clinical assessment of chest pain was made prospectively by 2 physicians. Graded supine bicycle exercise testing was symptom-limited. Right anterior oblique ECG-gated first-pass RVG and left anterior oblique ECG-gated equilibrium RVG were performed at rest and exercise. Regional wall motion abnormalities were defined by agreement of 2 of 3 blinded observers. A combined strongly positive exercise ECG response was defined as greater than or equal to 2 mm ST depression or 1.0 to 1.9 mm ST depression with exercise-induced chest pain. A multivariate logistic regression model for the preexercise prediction of CAD was derived from the clinical data and selected 2 variables: chest pain class and cholesterol level. A second model assessed the incremental value of the exercise test in prediction of CAD and found 2 exercise variables that improved prediction: RVG wall motion abnormalities, and a combined strongly positive ECG response. Applying the derived predictive models, 37 of the 58 patients (64%) with preexercise probabilities of 10 to 90% crossed either below the 10% probability threshold or above the 90% threshold and 28 (48%) also moved across the 5 and 95% thresholds. Supine exercise testing with ECG and biplane RVG together, but neither test alone, effectively adds to clinical prediction of CAD. It is most useful in men with atypical chest pain and when the ECG and RVG results are concordant

  5. Improved method of static radionuclide ventriculography

    International Nuclear Information System (INIS)

    Davidzon, G.S.; Myasnik, B.N.

    1988-01-01

    A method of 2-stage recording of radionuclide ventriculography has been proposed, the second stage being shifted to a certain time interval, i.e. a delay line is introduced between a synchronizing device and computer. Particular attention is drawn to a choice of delay time depending on a computer memory volume: in a small memory volume delay time must be approximately one-third of the patient's R-R interval

  6. Preoperative prediction of reversible myocardial asynergy by postexercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Rozanski, A.; Berman, D.; Gray, R.; Diamond, G.; Raymond, M.; Prause, J.; Maddahi, J.; Swan, H.J.; Matloff, J.

    1982-01-01

    Myocardial asynergy is sometimes reversed by coronary bypass, and a noninvasive method of predicting which assess are reversible would be desirable. To assess whether changes in myocardial wall motion observed immediately after exercise can differentiate reversible from nonreversible myocardial asynergy, we evaluated 53 patients by radionuclide ventriculography before and after exercise and again at rest after coronary bypass surgery. Preoperative improvement in wall motion immediately after exercise was highly predictive of the surgical outcome (average chance-corrected agreement, 91 per cent). At surgery the asynergic segments that had improved after exercise were free of grossly apparent epicardial scarring. The accuracy of these predictions for postoperative improvement was significantly greater (P less than 0.01) than that of analysis of Q waves on resting electrocardiography (average chance-corrected agreement, 40 per cent). In contrast, preoperative changes in left ventricular ejection fraction after exercise were not predictive of postoperative resting ejection fraction. We conclude that postexercise radionuclide ventriculography can be used to identify reversible resting myocardial asynergy. This test should prove effective in predicting which patients with myocardial asynergy are most likely to benefit from aortocoronary revascularization

  7. Potassium cardioplegia: early assessment by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Ellis, R.J.; Born, M.; Feit, T.; Ebert, P.A.

    1978-01-01

    Left ventricular function was evaluated by single pass /sup 99m/Tc radionuclide ventriculography when potassium cardioplegia was combined with hypothermia. In 35 patients undergoing myocardial revascularization (3 CABG/patient) in which potassium cardioplegia at 4 0 C was used, no patient developed a myocardial infarction either by electrocardiogram or /sup 99m/Tc pyrophosphate imaging in the postoperative period. In 22 patients, aortic cross-clamp time was greater than 60 min, and the ejection fraction by the single pass radionuclide technique was 50% preoperatively and 53% postoperatively (NS). Wall motion in the single RAO view was not worse postoperatively. No patient required any inotropic agents in the immediate postoperative period. It appears that no significant ventricular impairment occurred in the immediate postoperative period (48 to 72 hours) when potassium cardioplegia combined with hypothermia was used for a 60-minute period

  8. Myocardial perfusion and left ventricular function during exercise evaluated by 201Tl myocardial scintigraphy and 99mTc radionuclide ventriculography in patients treated with PTCA

    International Nuclear Information System (INIS)

    Honda, Toshio; Jo, Tadafumi; Doiuchi, Junji

    1992-01-01

    To evaluate the effects of percutaneous transluminal coronary angioplasty (PTCA), we investigated myocardial ischemia and left ventricular function during exercise before and after successful PTCA in 30 patients. We used extent and severity scores of 201 thallium ( 201 Tl) exercise myocardial scintigraphy to assess myocardial ischemia and determined global and regional left ventricular ejection fraction (EF and REF) of 99m Tc-RBC exercise radionuclide ventriculography to assess left ventricular function. The extent and severity scores of stress images were significantly less after PTCA than before PTCA. The scores of the redistribution images were unchanged before and after PTCA. Global EF during exercise was significantly higher after PTCA than before PTCA. There was no difference in resting global EF between before and after PTCA. Myocardial ischemia induced by exercise was semi-quantitatively analyzed as transient perfusion defect with severity score. Severity score was significantly less after PTCA than before PTCA. ΔEF, which was obtained by subtraction of resting global EF from exercise one, was significantly higher after PTCA than before PTCA. However, the degree of improvement in myocardial ischemia and left ventricular function varied from patient to patient. In 17 patients with one-vessel left anterior descending artery disease, ΔREF, which was determined by subtracting resting regional EF from exercise one, was significantly higher in septal and apical segments after PTCA than before PTCA. Myocardial ischemia and left ventricular function under exercise were alleviated by PTCA. However, the degree of improvement varied from patient to patient and it might have been affected by various factors including coronary dissection, edema, thrombus, restenosis, spasm, side branch stenosis or occlusion, distal thrombus, and myocardial hibernation. (author)

  9. Radionuclide ventriculography for evaluation of left ventricular function in patients after myocardial infarction

    International Nuclear Information System (INIS)

    Sledzevskaya, I.K.; Stroganova, N.P.; Il'yash, M.G.

    1989-01-01

    The use of an expanded set of parameters of radionuclide ventriculography with 99m Tc-prtechnetate, characterizing myocardial function, made it possible to specify radionuclide semiotics of myocardial infarction, to identify 4 cardiodynamic types, and to establish correlation between a degree of cardiodynamic changes and a site of lesion, and the relationship with exercise tolerance

  10. Comparison of exercise ECG and radionuclide ventriculography in the assessment of myocardial ischemia in patients with isolated stenoses of the left anterior descending artery

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Mildenberger, D.; Kaltenbach, M.; Standke, R.; Baum, R.P.; Tezak, S.; Maul, F.D.; Hoer, G.

    1988-01-01

    21 patients with LAD-stenoses of at least 70% and 21 patients with LAD-stenoses and additional intramural anterior wall infarctions were studied. 20 patients without heart disease or after successful transluminal coronary angioplasty and 18 patients with intramural anterior wall infarction after successful transluminal dilatation of the LAD (remaining stenosis maximal 30%) served as controls. The normal range of global and regional left ventricular ejection fraction response to exercise was defined based on the data of 25 further patients without relevant coronary heart disease. Thus, a decrease in global ejection fraction and regional wall motion abnormalities were judged pathological. All patients were comparable with respect to age, ejection fraction at rest and work load. Myocardial ischemia could be detected by the exercise ECG in 81% of all patients without infarction and in 71% of patients with infarction. The corresponding values for global left ventricular ejection fraction were 76% and 81%, respectively, and for regional ejection fraction 95% in both groups. No false-positive exercise ECGs were observed in the healthy controls and 2(11%) in the corresponding group with intramural infaction. The global ejection fraction was pathological in 1(5%) healthy subject without infarction and in 3(17%) corresponding patients with infarction. Sectorial analysis revealed 5 and 22%, respectively. Our findings suggest that the exercise ECG has a limited sensitivity to detect myocardial ischemia in patients with isolated LAD-stenoses and intramural myocardial infarction. Radionuclide ventriculography yields pathological values more often; however, false-positive results also occur more frequently. (orig.) [de

  11. Results of radionuclide ventriculography in normal children and adolescents

    International Nuclear Information System (INIS)

    Reich, O.; Krejcir, M.; Ruth, C.

    1989-01-01

    In order to assess the range of normal values in radionuclide ventriculography, 53 normal children and adolescents were selected in retrospect. All were exdamined by radionuclide angiocardiography on account of clinical and echocardiographical suspicion of congenital heart disease with a left-to-right shunt; a significant shunt was, however, excluded. In all patients, after equilibration of the radiopharmaceutical the ventricular function was examined by radionuclide ventriculography. The usual volume, time and rate characteristics were evaluated. The normal range was defined as the mean ±2 standard deviations which is 47 to 72% for the ejection fraction of the left ventricle and 31 to 56% for the ejection fraction of the right ventricle. (author). 2 tabs., 18 refs

  12. Receiver operating characteristic analysis improves diagnosis by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Dickinson, C.Z.; Forman, M.B.; Vaugh, W.K.; Sandler, M.P.; Kronenberg, M.W.

    1985-01-01

    Receiver operating characteristic analysis (ROC) evaluates continuous variables to define diagnostic criteria for the optimal sensitivity (SENS) and specificity (SPEC) of a test. The authors studied exercise-induced chest pain (CP), ST-changes on electrocardiography (ECG) and rest-exercise gated radionuclide ventriculography (RVG) using ROC to clarify the optimal criteria for detecting myocardial ischemia due to coronary artherosclerosis (CAD). The data of 95 consecutive patients studied with coronary angiography, rest-exercise RVG and ECG were reviewed. 77 patients had ''significant'' CAD (≥50% lesions). Exercise-induced CP, ECG abnormalities (ST-T shifts) and RVG abnormalities (change in ejection fraction, 2-view regional wall motion change and relative end-systolic volume) were evaluated to define optimal SENS/SPEC of each and for the combined data. ROC curves were constructed by multiple logistic regression (MLR). By MLR, RVG alone was superior to ECG and CP. The combination of all three produced the best ROC curve for the entire group and for clinical subsets based on the number of diseased vessels and the presence or absence of prior myocardial infarction. When CP, ECG and RVG were combined, the optimal SENS/SPEC for detection of single vessel disease was 88/86. The SENS/SPEC for 3 vessel disease was 93/95. Thus, the application of RVG for the diagnosis of myocardial ischemia is improved with the inclusion of ECG and CP data by the use of a multiple logistic regression model. ROC analysis allows clinical application of multiple data for diagnosing CAD at desired SENS/SPEC rather than by arbitrary single-standard criteria

  13. Radionuclide ventriculography in children with Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Tian Jiahe

    1992-01-01

    The ventricular functions of 22 children with Duchenne disease(DD) were studied by radionuclide multi-gated ventriculography using in-vivo labeled 99m Tc-RBC and compared with those of 30 age-matched normal children, 20 congenital heart disease and 7 congestive cardiomyopathy. 21 parameters were evaluated, including RV and LV EF, systolic and diastolic functions and phase distribution, etc. It was found that the DD patients showed several specific cardiac functional alterations, i.e, slight but significant abnormality in both systolic and diastolic function, special phase delay at post-lateral segment of LV in 81.8% of the patients. It is concluded that (1) all DD patients have definite evidence of heart injury; (2) the injury is mainly on the left side of the heart, influencing entire cardiac cycle; (3) there is specific phase abnormality in DD patients; (4) the radionuclide ventriculography is of great value in monitoring of these cardiac functional changes

  14. Assessment of ventricular function by radionuclide ventriculography in hyperthyroidism

    International Nuclear Information System (INIS)

    Dong Weiyu; He Pinyu; Zhuang Weite

    1996-01-01

    Left ventricular(LV) and right ventricular(RV) function were determined using radionuclide ventriculography in 50 patients with hyperthyroidism. LVEF, LVPFR, SV of the hyperthyroidism group were decreased in comparison with the normal group (P<0.01), whereas CO of the hyperthyroidism patients were higher than that of normal (P<0.01). Except LVPER, the LVEF, SV had significant difference between two groups. Compared to normal group, RVEF, RVPER, RVPFR were also decreased (P<0.01). Besides 30 cases of the hyperthyroidism were examined by impedance cardiogram (ICG) and impedance pulmonary rheogram (IPR), all showed closely correlation with the parameters determined by ventriculography. There was the involvement of right ventricular function insufficiency, especially in ejection phase. When compared with pre-therapy, pos-therapy cases showed significant improvement in EF, PER, PFR of left and right ventricular

  15. Equilibrium radionuclide ventriculography: Comparison with echo-ventriculography and digital subtraction angiocardiography, evaluation of multiparameters

    Energy Technology Data Exchange (ETDEWEB)

    Hoer, G; Standke, R; Klepzig, H Jr; Maul, F D; Tuengerthal, S; Tezak, S; Reifarth, N; Kanemoto, N; Happ, J; Baum, R P

    1986-09-01

    Subsequent to the discussion of technical prerequisites (fully-automated, reproducible multiparameter-analysis (MPA), rest, exercise) which is followed by remarks concerning the pathophysiology of ischemic left ventricular functional disorders in diastole and systole, the following points are considered: 1) comparative results of RNV, cineventriculoangiography, echo-ventriculography and intraveneous digital subtraction angiocardiography; 2) 'normal' values of RNV in MPA; 3) heart and pulmonary diseases (coronary artery disease with sensitivity and specificity of MPA), chronic obstructive pulmonary disease, chronic aortic insufficiency, hypertension; 4) summary of, and prospects for future potentialities (software, clinical indications).

  16. Quantitative assessment of valvular regurgitation using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Shi Rongfang

    1992-01-01

    Radionuclide ventriculography has been used to assess quantitatively the extent of mitral and aortic regurgitation in 70 patients and compared to echocardiography and the finding of surgery. Two radionuclide parameters were measured: regurgitant index (RI) = left ventricular stroke counts/right ventricular stroke counts; and regurgitant fraction (RF) = left ventricular stroke counts-right ventricular stroke counts/left ventricular stroke counts. In 28 patients without valvular heart disease, the RI was 1.10 ± 0.15 and Rf was 10.3 ± 15.0%, respectively. However, in patients with valvular regurgitation, the RI and RF were 3.41 ± 1.73 and 61.1 ± 21.2%, respectively. A good correlation was found between the results obtained by radionuclide techniques and the findings of surgery and doppler studies. The level of concordance between RI and surgical findings was 91.7%. Follow up studies in 10 patients after valvular replacement surgery showed the RI and RF return to normal. These data suggested that radionuclide ventriculography is very useful for quantitative assessment of valvular regurgitation

  17. Equilibrium radionuclide ventriculography in male patients after transmural myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Nestaval, A; Stanek, V; Malek, I; Kidery, J; Runczik, I [Institut pro Klinickou a Experimentalni Medicinu, Prague (Czechoslovakia); Cernoch, V; Oppelt, A [Institut pro Dalsi Vzdelavani Lekaru a Farmaceutu, Prague (Czechoslovakia)

    1982-12-17

    The ejection fraction of the left ventricle was measured using the method of equilibrium radionuclide ventriculography in 10 healthy males and 57 males after the first transmural myocardial infarction. The examination was effected 4 to 7 months after the event and the sample is representative for males after myocardial infarction who are younger than 65 years and show no signs of heart insufficiency by the time of examination. The resting value of the ejection fraction was 63+-5% in healthy males, 54+-7% in patients with uncomplicated myocardial infarction and 37+-8% in patients with clinical manifestations of heart insufficiency in acute phase. The differences between the groups are statistically significant. In patients with anteroseptal localization of myocardial infarction there was a negative correlation between the ejection fraction on the one hand and the sum of the voltages of Q waves in precordial ECG map and the maximum value of serum creatine kinase in acute phase on the other. The ejection fraction was in correlation to the degree of pulmonary hypertension measured in equal phase during exercise. The ejection fraction was measured in 31 patients under the working load of 50 W; significant changes were not found in healthy males or in patients after myocardial infarction. No changes were found when the state just before discharge from the hospital was compared with his state 6 months after myocardial infarction. The results obtained in compensated patients showed a relative stability of the value of the ejection fraction both during the first 6 months after discharge and under a mild working load. A comparison between the indicators in acute phase and hemodynamic examination after 6 months shows that the value of the ejection fraction is a sensitive indicator of the extent of necrosis and functional lesion of the left ventricle.

  18. Clinical assessment of first pass radionuclide ventriculography after dipyridamole infusion in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Kanaya, Tohru; Tono-oka, Ichiro; Satoh, Satoshi; Yamaguchi, Yoshiko; Hoshi, Hikaru; Ikeda, Kozue; Tsuiki, Kai; Yasui, Shoji; Komatani, Akio

    1986-01-01

    First pass radionuclide ventriculography (RNV) was performed after dipyridamole (D) infusion in 33 patients with coronary artery disease (CAD) and 15 normal volunteers. RNV findings after D infusion were compared with those of conventional exercise RNV and body surface ECG mapping (MAP). For patients with multiple vessel disease, left ventricular ejection fraction (LVEF) was significantly lower after D infusion than at rest. Wall motion abnormality (WMA) sites induced by D infusion were well coincident with those induced by exercise. Pressure rate product at exercise was significantly higher than that after D infusion, suggesting the different mechanism of the occurrence of WMA after D infusion and at exercise. The incidence of ischemic reaction tended to be higher after D infusion than at exercise in 25 patients with CAD. There was negative correlation between ST depression on MAP after D infusion and LVEF on RNV after D infusion. This RNV after D infusion can be used as a supplement tool to conventional exercise RNV in the evaluation of the degree of coronary artery lesions and preserved left ventricular function. (Namekawa, K.)

  19. Evaluation of segmental left ventricular wall motion by equilibrium gated radionuclide ventriculography.

    Science.gov (United States)

    Van Nostrand, D; Janowitz, W R; Holmes, D R; Cohen, H A

    1979-01-01

    The ability of equilibrium gated radionuclide ventriculography to detect segmental left ventricular (LV) wall motion abnormalities was determined in 26 patients undergoing cardiac catheterization. Multiple gated studies obtained in 30 degrees right anterior oblique and 45 degrees left anterior oblique projections, played back in a movie format, were compared to the corresponding LV ventriculograms. The LV wall in the two projections was divided into eight segments. Each segment was graded as normal, hypokinetic, akinetic, dyskinetic, or indeterminate. Thirteen percent of the segments in the gated images were indeterminate; 24 out of 27 of these were proximal or distal inferior wall segments. There was exact agreement in 86% of the remaining segments. The sensitivity of the radionuclide technique for detecting normal versus any abnormal wall motion was 71%, with a specificity of 99%. Equilibrium gated ventriculography is an excellent noninvasive technique for evaluating segmental LV wall motion. It is least reliable in assessing the proximal inferior wall and interventricular septum.

  20. Assessment of sistemic ventricle function in corrected transposition of great arteries with Gated SPECT: comparison with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Alexanderson, E.; Espinola, N.; Duenas, D.; Fermon, S.; Acevedo, C.; Martinez, C.

    2002-01-01

    Corrected trasposition of great arteries is a uncommon congenital heart disease where the right ventricle works as the sistemic one. QGS Gated SPECT program was designed to recognize the contours of left ventricle being a good method to evaluate left ventricle ejection fraction. The purpose of this study was to evaluate the right ventricle ejection fraction (RVEF) by gated SPECT using Tc-99mSestaMIBI in comparison with radionuclide ventriculography (RVG) in patients with corrected trasposition of great arteries. Methods: We performed gated SPECT and radionuclide ventriculography within 15 days of each other in 7 adults consecutive patients with the diagnosis of corrected trasposition of great arteries (5 men, 2 women; mean age 47 y). Gated tomographic data, including ventricular volumes and ejection fraction, were processed using QGS automatic algorithm, whereas equilibrium radionuclide ventriculography used standard techniques. Results: We found a good correlation between right ventricle ejection fraction obtained with Gated SPECT compared with equilibrium radionuclide ventriculography. The mean of the RVEF with Gated SPECT was 41.2% compared with 44.2% of RVEF with equilibrium radionuclide ventriculography. Both methods recognized abnormal RVEF in 5 patients ( 50%) with Gated SPECT and abnormal with RVG meanwhile another patient had normal RVEF with RVG and abnormal with Gated SPECT. Conclusion: Quantitative gated tomography, using Tc 99mSestaMIBI, has a good correlation with radionuclide ventriculography for the assessment of right ventricle ejection fraction in patients with corrected trasposition of great arteries. These results support the clinical use of this technique among these patients

  1. Gold-195m first-pass radionuclide ventriculography, thallium-201 single-photon emission CT, and 12-lead ECG stress testing as a combined procedure

    International Nuclear Information System (INIS)

    Kipper, S.L.; Ashburn, W.L.; Norris, S.L.; Rimkus, D.S.; Dillon, W.A.

    1985-01-01

    Graded, sequential, rest/exercise, gold-195m, first-pass ventriculography and thallium-201 (Tl-201) single-photon emission computed tomography (SPECT) were performed simultaneously during a single, electrocardiograph-monitored, bicycle stress test in 24 individuals. The technical aspects and logistics involved in performing this combined radionuclide study are stressed in this preliminary report. Fourteen healthy volunteers each had a normal left ventricular ejection fraction and wall-motion response, along with normal T1-201 perfusion and washout, as determined by both visual and quantitative analysis of the tomographic sections. Each of ten patients with coronary artery disease had at least one abnormality of these parameters. The authors suggest that it is technically feasible to evaluate both cardiac function and myocardial perfusion simultaneously by combing Au-195m ventriculography and Tl-201 SPECT imaging into a single, noninvasive, diagnostic package

  2. Attempts at diagnostic differentiation between dilatory cardiomyopathy and coronary heart disease on the basis of radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hefermann, R.

    1989-01-01

    It was the purpose of this study to find out which of the various parameters of radionuclide ventriculography would be suitable to determine whether a patient suffers from dilatory myocardiopathy (MCP) or coronary heart disease (CHD). Two groups of patients were examined using a mathematical procedure known as analysis of discriminance, in which the weights that individual parameters would have in a separation function were determined with the help of a computer programme. On the basis of these data, attempts were made to assign the patients of the different diagnostic groups. The parameters registered at rest, which were FSMIN, EFAFI (end of fast filling) and CONTR (contraction), led to a total of five diagnostic errors, with one case of CHD being classified as CMP and four CMP patients as having CHD. On the basis of the parameters measured during exercise), which were RELAX (relaxation), stroke volume and PETI (peak ejection time), only one CMP patient was erroneously assigned to the CHD group. When the parameters of RNV at rest and during exercise were combined to give FSMINR (minimum of highest factor minus lowest factor at rest), DFSDIFF (difference between F-S at rest and during exercise) and DMINVOL (difference between heart minute volumes at rest and during exercise), the classifications were correct for all of the 30 study participants (100%). This led us to conclude that the RNV parameters chosen permitted reliable diagnostic discriminations to be made between those two groups of patients. (orig./MG) [de

  3. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  4. Analysis of cardiac images of radionuclide ventriculography in AT-Type personal computer

    International Nuclear Information System (INIS)

    Lillo, R.; Gonzalez, P.; Ehijo, A.; Otarola, T.M.S.; Ortiz, M.; Silva, A.M.; Ortiz, M.

    1990-01-01

    The goal of this research was to produce software for the processing of Cardiac Phase images in personal computers. The results of standard radionuclide Ventriculography and Fourier analysis, got on gamma camera Ohio Nuclear 410 Sygma and Digital PDP 11/34 computer were coded into ASCII file and then transfered via Smarterm 220/Kermit to an Accel 900 AT PC. After decoding the images they were processed with a program develope in C Lenguaje obtaining the values of Phase Angles in the whole phase images and in regions of interest drawn around the cardiac chambers. The images and values were the same as those obtained by conventional processing in the PDP 11/34 computer. This is considered a first stage for the use of PC to Nuclear Medicine imaging studies. (author)

  5. Relative value of clinical variables, bicycle ergometry, rest radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring at discharge to predict 1 year survival after myocardial infarction

    NARCIS (Netherlands)

    P.M. Fioretti (Paolo); R.W. Brower (Ronald); M.L. Simoons (Maarten); H.J. ten Katen (Harald); A. Beelen (Anita); T. Baardman (Taco); J. Lubsen (Jacob); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractThe relative value of predischarge clinical variables, bicycle ergometry, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring for predicting survival during the first year in 351 hospital survivors of acute myocardial infarction was assessed. Discriminant

  6. Exercise radionuclide ventriculographic responses in hypertensive patients with chest pain

    International Nuclear Information System (INIS)

    Wasserman, A.G.; Katz, R.J.; Varghese, P.J.; Leiboff, R.H.; Bren, G.G.; Schlesselman, S.; Varma, V.M.; Reba, R.C.; Ross, A.M.

    1984-01-01

    The effectiveness of exercise-treadmill testing in diagnosing coronary-artery disease in hypertensive patients is limited by a high rate of false positivity. Exercise radionuclide ventriculography, however, relies on different criteria (ejection fraction and wall motion), and we have evaluated this procedure in 37 hypertensive and 109 normotensive patients with chest pain, using coronary arteriography as an indicator of coronary disease. In the hypertensive cohort there was no difference in the ejection fraction at rest between the 17 patients with coronary disease and the 20 without it. Neither group had a significant mean (+/- S.E.M.) change in ejection fraction from rest to exercise (-1.9 +/- 2 and 1.4 +/- 1%, respectively). A wall-motion abnormality developed during exercise in 5 of the 17 hypertensive patients with coronary disease (29%) and in 4 of the 20 without it (20%) (P = not significant). In the normotensive cohort, however, the peak-exercise ejection fractions were significantly different. The 71 patients with coronary disease had a mean decrease of 3.6 +/- 1%, in contrast to the patients without coronary disease, who had an increase of +/- 1% (P < 0.001). An exercise-induced wall-motion abnormality was seen in 35 of the 71 patients with coronary disease (48%), as compared with 3 of the 38 without it (8%) (P < 0.001). We conclude that exercise radionuclide ventriculography is inadequate as a screening test for coronary atherosclerosis in hypertensive patients with chest pain. 28 references, 2 figures, 3 tables

  7. Problems in clinical assessment of left ventricular peak filling rate with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Kim, Bong-Ha; Tsuneoka, Yutaka

    1987-02-01

    With an increased clinical application of early peak diastolic filling rate (PFR) using radionuclide ventriculography, problems of its clinical significance have emerged. The study was designed to answer the following questions: 1) accuracy of PFR measurement, 2) normalization of PFR, and 3) whether PFR may reflect left ventricular relaxation rate (LVRR). In measuring PFR, an elevated framing rate was required, and the optimal rate was 20 msec/F. Second sound heart gating technique proved to be complementary to conventional ECG R wave gating technique in the evaluation of left ventricular diastolic volume curves and mean filling rate associated with changes in the range of R-R interval. PFR which was normalized with end-diastolic volume (EDV) did not necessarily reflect measured PFR because of individual differences of EDV. An experiment on the relationship of mitral valve pressure to blood flow in dogs revealed that PFR was influenced by not only LVRR but also left atrial pressure. These results may raise a question of the rationale for using the measurement of PFR, as well as its technical problems, in the objective evaluation of LVRR. (Namekawa, K.).

  8. Effects of AV delay programming on ventricular resynchronisation: role of radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Siegrist, Patrick T.; Comte, Nathalie; Holzmeister, Johannes; Suetsch, Gabor; Koepfli, Pascal; Namdar, Mehdi; Duru, Firat; Brunckhorst, Corinna; Scharf, Christoph [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2008-08-15

    Optimal atrioventricular delay (AVD) setting for cardiac resynchronisation therapy, i.e. biventricular pacing in patients with heart failure, remains a formidable challenge. Thus, the purpose of this study was to evaluate the effects of different AVD on inter- and intra-ventricular resynchronisation using phase histograms of radionuclide ventriculography (RNV). In 17 consecutive patients (mean age 64 {+-} 6 years), RNV was performed 236 {+-} 350 days after pacemaker implantation for cardiac resynchronisation therapy. Images were acquired during atrial pacing at 80 bpm and during biventricular pacing with AVD ranging from 80 to 160 ms. Inter-ventricular dyssynchrony was measured by the delay between the mean phase angles of the left and right ventricles. Intra-ventricular dyssynchrony was measured by the standard deviation (SD) of left ventricular phase histograms. Left ventricular (LV) ejection fraction (EF) was inversely correlated to LV dyssynchrony (SD of LV phase histogram, R = -0.82, p < 0.0001). However, the increase in LVEF by biventricular pacing (mean +4.4 {+-} 4%) showed only modest correlation to the resulting resynchronisation effect (characterised by a -13 {+-} 8 decrease in LV phase histogram SD, R = -0.38, p < 0.0001). RNV is helpful in optimising pacing parameters for resynchronisation therapy. Varying AVD did not have a major impact on intra- or inter-ventricular resynchronisation. Thus, the benefit of AVD-based LVEF optimisation seems to result from atrioventricular resynchronisation. (orig.)

  9. Left ventricle expands maximally preceding end-diastole. Radionuclide ventriculography study

    International Nuclear Information System (INIS)

    Horinouchi, Osamu

    2002-01-01

    It has been considered that left ventricle (LV) expands maximally at the end-diastole. However, is it exactly coincident with this point? This study was aimed to determine whether the maximal expansion of LV coincides with the peak of R wave on electrocardiogram. Thirty-three angina pectoris patients with normal LV motion were examined using radionuclide ventriculography. Data were obtained from every 30 ms backward frame from the peak of R wave. All patients showed the time of maximal expansion preceded the peak of R wave. The intervals from the peak of R wave and the onset of P wave to maximal expansion of LV was 105±29 ms and 88±25 ms, respectively. This period corresponds to the timing of maximal excurtion of mitral valve by atrial contraction, and the centripetal motion of LV without losing its volume before end-diastole may be interpreted on account of the movement of mitral valve toward closure. These findings suggest that LV expands maximally between P and R wave after atrial contraction, preceding the peak of R wave thought conventionally as the end-diastole. (author)

  10. Effect of acute postinfusion lipemia and free fatty acids on myocardial contractility: Assessment with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Ackerman, L; Freeman, M L; Barnes, W E; Kaplan, E; Pacold, I; Loeb, H S; Johnson, B; Reid, R W

    1986-08-01

    Equilibrium gated radionuclide ventriculography was used to valuate the effect of intravenous fat-emulsion overload and excess of free fatty acids (FFA) on left ventricular ejection fraction (LVEF) in 20 patients with and without coronary artery disease (CAD). Fifteen of these patients had normal (>50%) baseline LVEF and 5 had low (<50%) baseline LVEF. From 100 to 150 ml of 20% artificial fat emulsion (Liposyn) was infused over 20-25 min. At the end of the infusion, triglyceridemia reached 820 +- 220 mg% and left ventricular ejection fraction decreased from baseline 62 +- 19% (mean +-SD) to 58 +- 16% (P < 0.05, paired t-test). After completion of Liposyn infusion, 5,000 U of heparin was administered intravenously and monitoring of LVEF was continued. One and one-half hours following heparin administration, plasma FFA levels reached 3.7 + 2.0 mmol/l and LVEF rose to 69 +- 19% (P < 0.001, paired t-test). Our data indicate that acute intravenous fat overload can suppress and high pathophysiologic levels of FFA can increase LVEF. This effect is more uniform and statistically more reliable in patients with normal LVEF. The study failed to demonstrate any significant difference in the effect of this pharmacologic intervention between patients with and without CAD.

  11. Clinical validation of the planar radionuclide ventriculography in patients with right ventricular dysfunction.

    Science.gov (United States)

    Bontemps, L; Merabet, Y; Chevalier, P; Itti, R

    2013-01-01

    Gated radionuclide ventriculography (RNV) may be used for the evaluation of the right ventricular function. However, the accuracy of the method should be clinically validated in patients suffering from diseases with specific pathology of the right ventricle (RV) and with possible left ventricular (LV) interaction. Three groups of 15 patients each, diagnosed with arrhythmogenic right ventricular dysplasia (ARVD), pulmonary artery hypertension (PAH) or atrial septal defect (ASD) were compared to a group of normal subjects. The parameters for both ventricles were evaluated separately (ejection fractions: LVEF and RVEF, and intraventricular synchronism quantified as phase standard deviation: LVPSD and RVPSD) as well as the relation or interdependence of the right to left ventricle (RV/LV volume ratio, LV/RV ejection fraction and stroke volume ratios, and interventricular synchronism). All the variables as a whole were analyzed to identify groups of patients according to their functional behaviour. Significant differences were found between the patients and control group for the RV function while the LV function remained mostly within normal limits. When the RV function was considered, the control group and ASD patient group showed differences regarding the ARVD and PAH patients. On evaluating the RV/LV ratios, differences were found between the control group and the ASD group. In the PAH patients, LV function showed differences in relation to the rest of the groups. RNV is a reliable clinical tool to evaluate RV function in patients with RV abnormality. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  12. A study of the global and regional ventricle function using radionuclide ventriculography in the cases of patients with and without KHK under nitrate and placebo

    International Nuclear Information System (INIS)

    Kroth, B.

    1983-01-01

    In a controlled study of 74 patients with coronary heart disease (KHK) or without provable heart disease the ventricle function at rest and under ergonomic load before and after oral administration of nitrates, respectively placebos was studied with the help of radionuclide ventriculography. Radionuclide ventriculography proved itself thereby as a valuable method of high sensitivity for the recognition of KHK. The stress test increases the sensitivity and allows inferences to be made on the extent of the ischemia. The global function at rest is more a parameter for the functional restriction by infarct scars. A quantitative regional evaluation also makes possible the recognition of minor local changes. The additional study after nitrate administration allows a basis for the extent of reversibility in the stress-dependent functional restriction. The effects of a drug therapy become extrinsically presentable as a result of radionuclide ventriculography. (TRV) [de

  13. Radionuclide ventriculography during rest and exercise: normal values

    International Nuclear Information System (INIS)

    Ludwig, E.B.; Marroni, B.J.; Achutti, A.C.; Anselmi, O.E.; Rabin, M.

    1983-01-01

    Twenty young volunteers of both sexes were examined by radioisotopic techniques to establish the normal range of ventricular function at rest and the response to a stress test (systolic arterious pressure X cardiac frequency > 25000). (M.A.C.) [pt

  14. Comparison of two-dimensional echocardiography with gated radionuclide ventriculography in the evaluation of global and regional left ventricular function in acute myocardial infarction

    International Nuclear Information System (INIS)

    Van Reet, R.E.; Quinones, M.A.; Poliner, L.R.; Nelson, J.G.; Waggoner, A.D.; Kanon, D.; Lubetkin, S.J.; Pratt, C.M.; Winters, W.L. Jr.

    1984-01-01

    Two-dimensional echocardiography and gated radionuclide ventriculography were performed in 93 patients (66 men, 27 women; mean age 61 years) with 95 episodes of acute myocardial infarction within 48 hours and at 10 days after infarction. Abnormal motion of an inferior or posterior wall segment was seen in 91% of inferoposterior infarctions by echocardiography versus 61% seen by radionuclide ventriculography. Ejection fractions determined by echocardiography and radionuclide ventriculography correlated well (r . 0.82) and did not change from the first 48 hours to 10 days after infarction (0.48 +/- 0.14). Similarly, wall motion score showed minimal change from the first 48 hours to 10 days. In-hospital mortality was 37 and 42% in patients with an ejection fraction of 0.35 or less by echocardiography and radionuclide ventriculography, respectively. No mortality was seen in patients with an ejection fraction above 0.40 by either test. The echocardiographic wall motion score was also predictive of mortality (40 versus 2%; score less than or equal to 0.50 versus greater than 0.50). The 1 year mortality rate in the 81 short-term survivors was 17%. Mortality was lowest in patients with an ejection fraction above 0.49 or wall motion score above (0.79 (2 to 5%) and worse in those with an ejection fraction below 0.36 or wall motion score below 0.51 (36 to 63%) by either technique. Thus in acute myocardial infarction, echocardiography and radionuclide ventriculography provide a comparable assessment of left ventricular function and wall motion in anterior infarction. Echocardiography appears more sensitive in detecting inferoposterior wall motion abnormalities. Both techniques are capable of identifying subgroups of patients with a high risk of death during the acute event and with an equally high mortality rate over a 1 year follow-up period

  15. Application of radionuclide ventriculography phase analysis in patients with atrial or ventricular pacing for detecting ventricular abnormal excitation

    International Nuclear Information System (INIS)

    Shi Rongfang; Wang Zhonggan; Li Shengting

    1996-01-01

    The aim of the study was to increase the accuracy of detecting ventricular abnormal excitation. During atrial or ventricular pacing, radionuclide ventriculography phase analysis (RNV-PA) was performed in 17 patients with Wolff-Parkinson-White (W-P-W) syndrome and paroxysmal supra ventricular tachycardia (PSVT) and ventricular tachycardia (PVT). During pacing, detection rate of abnormal excitation by RNV-PA was 95.5%, compared with 68.2% during basic conduction. Atrial or ventricular pacing can significantly increase the detection rate of abnormal excitation by RNV-PA in patients with W-P-W syndrome. It may be a valuable method for identifying the abnormal excitation and estimating the therapeutic effect of ablation

  16. Intravenous streptokinase therapy in acute myocardial infarction: Assessment of therapy effects by quantitative 201Tl myocardial imaging (including SPECT) and radionuclide ventriculography

    International Nuclear Information System (INIS)

    Koehn, H.; Bialonczyk, C.; Mostbeck, A.; Frohner, K.; Unger, G.; Steinbach, K.

    1984-01-01

    To evaluate a potential beneficial effect of systemic streptokinase therapy in acute myocardial infarction, 36 patients treated with streptokinase intravenously were assessed by radionuclide ventriculography and quantitative 201 Tl myocardial imaging (including SPECT) in comparison with 18 conventionally treated patients. Patients after thrombolysis had significantly higher EF, PFR, and PER as well as fewer wall motion abnormalities compared with controls. These differences were also observed in the subset of patients with anterior wall infarction (AMI), but not in patients with inferior wall infarction (IMI). Quantitative 201 Tl imaging demonstrated significantly smaller percent myocardial defects and fewer pathological stress segments in patients with thrombolysis compared with controls. The same differences were also found in both AMI and IMI patients. Our data suggest a favorable effect of intravenous streptokinase on recovery of left ventricular function and myocardial salvage. Radionuclide ventriculography and quantitative 201 Tl myocardial imaging seem to be reliable tools for objective assessment of therapy effects. (orig.)

  17. Pharmacological radionuclide ventriculography for detection of myocardial contractile reserve in patients after myocardial infarction: head-to-head comparison of low dose dobutamine and low dose dypiridamole

    International Nuclear Information System (INIS)

    Petrasinovic, Z.; Ostojic, M.; Beleslin, B.; Stojkovic, S.; Nedeljkovic, M.; Stankovic, G.; Dikic, A.; Pavlovic, S.; Sobic, D.

    2002-01-01

    Background. Low dose pharmacological stress echocardiography with either dobutamine or dipyridamole infusion has been proposed for recognition of myocardial viability. However, dependence on adequate acoustic window, observer experience, and the mild degree of wall motion changes make the viability assessment by stress echocardiography especially bothersome. The objective of the study was to evaluate the ability of low dose dobutamine and low dose dipyridamole radionuclide ventriculography to detect contractile reserve in patients after myocardial infarction and functional recovery after coronary angioplasty. Methods. The study group consisted of 20 consecutive patients (52±10 years, 17 male) with previous myocardial infarction and resting regional dyssynergy, in whom diagnostic cardiac catheterization revealed significant one-vessel coronary artery stenosis suitable for angioplasty. Each patient underwent equilibrium 99m-Tc radionuclide ventriculography which was performed at rest and during low dose dipyridamole (0.28 mg/kg over 2 minutes) and low dose dobutamine infusion (up to 10 mcg/kg/min). Left ventricular global and regional ejection fractions were determined. Increase of regional ejection fraction for >5% (inferoapical and posterolateral regions) or >10% (anteroseptal regions) during low dose dobutamine and dipyridamole in infarcted regions, as well as in the follow up period, was considered as index of contractile reserve. After 8 weeks of successful angioplasty, resting radionuclide ventriculography was repeated in all patients in order to identify functional recovery of the infarct zone. Results. Out of the 180 analyzed segments (20x9), 90 regional ejection fractions have shown depressed contractility. The mean of the regional ejection fractions showing depressed contractility increased from the resting value of 34±12% to 42±14% in the follow-up period (p=0.06). Of the 90 with baseline dyssynergy, 46 were responders during low-dose dobutamine (51

  18. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    International Nuclear Information System (INIS)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.; Kass, R.M.; Raymond, M.J.; Garcia, E.V.; Chaux, A.; Matloff, J.M.; Berman, D.S.

    1984-01-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and left ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers

  19. Combined evaluation of first-pass radionuclide angiography and epuilibrium radionuclide ventriculography in the diagnosis of coronary artery disease. Pt. 1

    International Nuclear Information System (INIS)

    Knesewitsch, P.; Kleinhans, E.; Buell, U.

    1986-01-01

    The results of 203 patients who underwent first-pass radionuclide angiography (FP), as well as quantitative equilibrium radionuclide ventriculography (qERNV), were stored in a data base system and evaluated statistically. In patients with coronary artery disease (CAD) without previous myocardial infarction (MI), evaluation of global and regional ejection fraction (gEF, rEF) at rest revealed a poor sensitivity of 64% (Rest-qERNV) and 69% (Rest-FP), respectively. In patients with a history of one previous MI, the sensitivity of both methods was equivalent: FP 87% and qERNV 84%. In patients with several MIs, sensitivity was higher than 90%. Concerning localization of MI, remarkable differences between FP and qERNV were found. In posterior wall infarction, the FP sensitivity was 87% and qERNV only 67%, whereas in anterior wall infarction, the results were similar for both methods.: 93% (FP) and 96% (qERNV), respectively. Since 30 0 RAO camera position achieves the best visualization of the anterior and posterior wall, FP is superior to qERNV in the evaluation of posterior wall asynergies. In addition, qERNV often fails to discriminate anterior and posterior wall motion abnormalities. (orig.)

  20. Evaluation of right ventricular function using gated equilibrium blood pool radionuclide ventriculography in patients with congenital volume and pressure overload late after surgical repair

    International Nuclear Information System (INIS)

    Hirata, Nobuaki; Sakakibara, Tetsuo; Watanabe, Shinichiro; Nomura, Fumikazu; Akamatsu, Hiroki; Matsumura, Yasushi; Yamamoto, Kazuhiro; Sasaki, Jiro; Kodama, Kazuhisa

    1991-01-01

    The effects of congenital right ventricular pressure and volume overload were studied in 3 patients with pulmonary stenosis, 7 with atrial septal defect and 6 with atrial septal defect plus pulmonary stenosis late after successful surgical correction. Gated equilibrium blood pool radionuclide ventriculography was used to measure right ventricular function at rest and during exercise and to compare it with eight normal subjects. Right ventricular ejection fractions at rest and during exercise were measured to be 61±9% and 66±13%, respectively, in the group with pulmonary stenosis, 49±7% and 54±8% in the group with atrial septal defect, and 65±13% and 69±13% in the group with atrial septal defect plus pulmonary stenosis. The values in the groups with pulmonary stenosis and atrial septal defect plus pulmonary stenosis were significantly higher than the control subjects (45±5% and 51±5%, p<0.01). The peak filling rate at rest and during exercise was also significantly higher in the groups with pulmonary stenosis and atrial septal defect plus pulmonary stenosis than in controls (at rest, 2.72±0.72, 2.53±0.94 vs. 1.64±0.24 p<0.05; during exercise, 4.38±1.23, 4.13±1.18 vs. 2.25±0.62, p<0.01). When patients with right ventricular systolic pressure equal to or greater than left ventricular systolic pressure and those with right ventricular systolic pressure less than left ventricular systolic pressure were compared, the right ventricular ejection fraction and peak filling rate were greater with the higher pressure at rest (71±10% and 3.12±0.81% vs. 55±3% and 2.30±0.27, p<0.05) and during exercise (75±11% and 4.86±1.01 vs. 59±3% and 2.61±0.35, p<0.05). Postoperative right ventricular hyperfunction may be due to preoperative pressure, but not volume, overload. (author)

  1. Radionuclide ventriculographic evaluation of exercised left ventricular performance in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Fujii, Yusuke; Hara, Fumio

    1991-01-01

    Radionuclide ventriculography was made in 49 asymptomatic diabetic patients, aged 30∼70 years, to investigate cardiac function. Comparisons were made with 33 age- and sex-matched non-diabetic controls. Radionuclide ventriculography was performed at rest and during dynamic exercise by multigraded, supine bicycle ergometer. The resting left ventricular ejection fractions were similar between the diabetic patients and control subjects. No significant rise in the left ventricular ejection fractions during dynamic exercise was observed in the diabetic patients [58.4±9.8% (mean±SD) to 60.3±9.9]. In the control subjects, the left ventricular ejection fractions increased during dynamic exercise [59.3±8.4 to 63.0±11.4 (p -1 ) vs -2.66±0.52] and during dynamic exercise [-3.25±0.74 vs -3.23±0.90]. Time to end-systole were similar in both groups at rest [315±42 (ms) vs 309±42] and during dynamic exercise [258±37 vs 262±37]. The resting peak filling rates were similar in both groups [2.27±0.62 (s -1 ) vs 2.45±0.58], and the peak filling rates increased (p 1c in the diabetic patients. These results suggest that diabetic patients have less cardiac reserved performance. (author)

  2. Comparison between Radionuclide Ventriculography and Echocardiography for Quantification of Left Ventricular Systolic Function in Rats Exposed to Doxorubicin

    Directory of Open Access Journals (Sweden)

    Luciano Fonseca Lemos de Oliveira

    Full Text Available Abstract Background: Radionuclide ventriculography (RV is a validated method to evaluate the left ventricular systolic function (LVSF in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. Objectives: To compare the results of LVSF obtained by RV and echocardiography (ECHO in an experimental model of cardiotoxicity due to doxorubicin (DXR in rats. Methods: Adult male Wistar rats serving as controls (n = 7 or receiving DXR (n = 22 in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. Results: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05. The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05; however, the LVSF values obtained by RV (60.6 ± 12.5% were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004 in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002 and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001. On multiple regression analysis, only RV correlated independently with myocardial fibrosis. Conclusion: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity.

  3. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jin; Takeda, Tohoru; Ajisaka, Ryuichi; Masuoka, Takeshi; Watanabe, Sigeyuki; Sato, Motohiro; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Toyama, Hinako; Ishikawa, Nobuyoshi

    1999-02-01

    To understand the effect of hyperventilation (HV) stress in patients with spastic angina, left ventricular (LV) contraction was analyzed by quantitative phase analysis. The study was performed on 36 patients with spastic angina pectoris, including vasospastic angina pectoris (VspAP: 16 patients) and variant angina pectoris (VAP: 20 patients). First-pass radionuclide ventriculography (first-pass RNV) was performed at rest and after HV stress, and standard deviation of the LV phase distribution (SD) was analyzed. The SD was lower in patients with VspAP than in VAP(12.8{+-}1.4 degrees vs. 14.6{+-}2.2 degrees, p<0.005) at rest. After HV stress, the SD (HVSD) tended to increase in VspAP patients (62.5%), whereas the SD decreased in VAP patients (70%). Due to HV stress, the percentage change in SD (%SD) in VspAP patients was 8.9{+-}23.7% whereas that in VAP patients was -9.1{+-}17.3% (p<0.01). Moreover, phase histograms were divided into HVSD increase and HVSD decrease groups. The HVSD increase group had a decrease of HVEF, but the HVSD decrease group tended to have more decreased HVEF than the HVSD increase group. These results indicate that spastic angina pectoris patients show various responses to HV stress. The HVSD increase group might have additional myocardial ischemia due to regional coronary spasm. In contrast, in the HVSD decrease group severe LV dysfunction or diffuse wall motion abnormality might have been generated, and this caused a reduction in the SD value. Phase analysis would therefore add new information regarding electrocardiographically silent myocardial ischemia due to coronary spasm, and HV stress might increase sensitivity for the detection of abnormalities in quantitative phase analysis, especially in VspAP patients. (author)

  4. Comparison between radionuclide ventriculography and echocardiography for quantification of left ventricular systolic function in rats exposed to doxorubicin

    International Nuclear Information System (INIS)

    Oliveira, Luciano Fonseca Lemos de; Carvalho, Eduardo Elias Vieira de; Romano, Minna Moreira Dias; Maciel, Benedito Carlos; Simões, Marcus Vinicius

    2017-01-01

    Background: Radionuclide ventriculography (RV) is a validated method to evaluate the left ventricular systolic function (LVSF) in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. Objectives: To compare the results of LVSF obtained by RV and echocardiography (ECHO) in an experimental model of cardiotoxicity due to doxorubicin (DXR) in rats. Methods: Adult male Wistar rats serving as controls (n = 7) or receiving DXR (n = 22) in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer) and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. Results: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05). The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05); however, the LVSF values obtained by RV (60.6 ± 12.5%) were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004) in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002) and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001). On multiple regression analysis, only RV correlated independently with myocardial fibrosis. Conclusion: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity. (author)

  5. Evaluation of aortic and mitral valve regurgitation by radionuclide ventriculography: comparison with the method of Sandler and Dodge

    Energy Technology Data Exchange (ETDEWEB)

    Kress, P.; Geffers, H.; Stauch, M.; Nechwatal, W.; Sigel, H.; Bitter, F.; Adam, W.E.

    1981-01-01

    The present investigation was undertaken to introduce a quantitative scintigraphic method for evaluation of regurgitation and to compare it with the generally accepted quantitative method of Sandler and Dodge. Radionuclide ventriculography was carried out after injection of 20 mCi 99mtechnetium-labeled red blood cells. Time-activity curves were obtained from the left and right ventricular regions. The ratio of end-diastolic-end-systolic count-rate differences for the left and right ventricles was calculated. The ratio (A) was compared with a hemodynamic ratio determined after the method of Sandler and Dodge with the stroke volume of the left ventricle measured angiographically, and the stroke volume of the right ventricle measured by thermodilution. In 33 patients with aortic and mitral valve regurgitation researchers found a correlation of r . 0.75. Due to a broad range of normal values of the sensitivity of the scintigraphic method is low. The specificity seems to be high, however, since in 64 patients with all types of heart diseases there were no false positive results. Comparing the described scintigraphic method with other modern or generally accepted methods, the principal advantages are noninvasiveness, good practicability, and the fact that important additional information about the functional state of the heart is gained. This is important in follow-up studies in patients with chronic valvular incompetence. It seems that this method will become a valuable supplement to heart catheterization in the diagnosis of valvular heart disease and may partially replace invasive methods for measuring the regurgitation fraction.

  6. Evaluation of aortic and mitral valve regurgitation by radionuclide ventriculography: comparison with the method of Sandler and Dodge

    International Nuclear Information System (INIS)

    Kress, P.; Geffers, H.; Stauch, M.; Nechwatal, W.; Sigel, H.; Bitter, F.; Adam, W.E.

    1981-01-01

    The present investigation was undertaken to introduce a quantitative scintigraphic method for evaluation of regurgitation and to compare it with the generally accepted quantitative method of Sandler and Dodge. Radionuclide ventriculography was carried out after injection of 20 mCi 99mtechnetium-labeled red blood cells. Time-activity curves were obtained from the left and right ventricular regions. The ratio of end-diastolic-end-systolic count-rate differences for the left and right ventricles was calculated. The ratio (A) was compared with a hemodynamic ratio determined after the method of Sandler and Dodge with the stroke volume of the left ventricle measured angiographically, and the stroke volume of the right ventricle measured by thermodilution. In 33 patients with aortic and mitral valve regurgitation researchers found a correlation of r . 0.75. Due to a broad range of normal values of the sensitivity of the scintigraphic method is low. The specificity seems to be high, however, since in 64 patients with all types of heart diseases there were no false positive results. Comparing the described scintigraphic method with other modern or generally accepted methods, the principal advantages are noninvasiveness, good practicability, and the fact that important additional information about the functional state of the heart is gained. This is important in follow-up studies in patients with chronic valvular incompetence. It seems that this method will become a valuable supplement to heart catheterization in the diagnosis of valvular heart disease and may partially replace invasive methods for measuring the regurgitation fraction

  7. Comparison between radionuclide ventriculography and echocardiography for quantification of left ventricular systolic function in rats exposed to doxorubicin

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luciano Fonseca Lemos de; Carvalho, Eduardo Elias Vieira de; Romano, Minna Moreira Dias; Maciel, Benedito Carlos; Simões, Marcus Vinicius, E-mail: msimoes@fmrp.usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Centro de Cardiologia; O' Connell, João Lucas; Pulici, Érica Carolina Campos [Universidade Federal de Uberlândia (UFU), MG (Brazil)

    2017-01-15

    Background: Radionuclide ventriculography (RV) is a validated method to evaluate the left ventricular systolic function (LVSF) in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. Objectives: To compare the results of LVSF obtained by RV and echocardiography (ECHO) in an experimental model of cardiotoxicity due to doxorubicin (DXR) in rats. Methods: Adult male Wistar rats serving as controls (n = 7) or receiving DXR (n = 22) in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer) and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. Results: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05). The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05); however, the LVSF values obtained by RV (60.6 ± 12.5%) were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004) in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002) and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001). On multiple regression analysis, only RV correlated independently with myocardial fibrosis. Conclusion: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity. (author)

  8. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography

    International Nuclear Information System (INIS)

    Wu, Jin; Takeda, Tohoru; Ajisaka, Ryuichi; Masuoka, Takeshi; Watanabe, Sigeyuki; Sato, Motohiro; Itai, Yuji; Toyama, Hinako; Ishikawa, Nobuyoshi

    1999-01-01

    To understand the effect of hyperventilation (HV) stress in patients with spastic angina, left ventricular (LV) contraction was analyzed by quantitative phase analysis. The study was performed on 36 patients with spastic angina pectoris, including vasospastic angina pectoris (VspAP: 16 patients) and variant angina pectoris (VAP: 20 patients). First-pass radionuclide ventriculography (first-pass RNV) was performed at rest and after HV stress, and standard deviation of the LV phase distribution (SD) was analyzed. The SD was lower in patients with VspAP than in VAP(12.8±1.4 degrees vs. 14.6±2.2 degrees, p<0.005) at rest. After HV stress, the SD (HVSD) tended to increase in VspAP patients (62.5%), whereas the SD decreased in VAP patients (70%). Due to HV stress, the percentage change in SD (%SD) in VspAP patients was 8.9±23.7% whereas that in VAP patients was -9.1±17.3% (p<0.01). Moreover, phase histograms were divided into HVSD increase and HVSD decrease groups. The HVSD increase group had a decrease of HVEF, but the HVSD decrease group tended to have more decreased HVEF than the HVSD increase group. These results indicate that spastic angina pectoris patients show various responses to HV stress. The HVSD increase group might have additional myocardial ischemia due to regional coronary spasm. In contrast, in the HVSD decrease group severe LV dysfunction or diffuse wall motion abnormality might have been generated, and this caused a reduction in the SD value. Phase analysis would therefore add new information regarding electrocardiographically silent myocardial ischemia due to coronary spasm, and HV stress might increase sensitivity for the detection of abnormalities in quantitative phase analysis, especially in VspAP patients. (author)

  9. Fourier phase analysis on equilibrium gated radionuclide ventriculography: range of phase spread and cut-off limits in normal individuals

    International Nuclear Information System (INIS)

    Ramaiah, Vijayaraghavan L.; Harish, B.; Sunil, H.V.; Selvakumar, Job; Ravi Kishore, A.G.; Nair, Gopinathan

    2011-01-01

    To define the range of phase spread on equilibrium gated radionuclide ventriculography (ERNV) in normal individuals and derive the cut-off limit for the parameters to detect cardiac dyssynchrony. ERNV was carried out in 30 individuals (age 53±23 years, 25 males and 5 females) who had no history of cardiovascular disease. They all had normal left ventricular ejection fraction (LVEF 55-70%) as determined by echocardiography, were in sinus rhythm, with normal QRS duration (≤120 msec) and normal coronary angiography. First harmonic phase analysis was performed on scintigraphic data acquired in best septal view. Left and right ventricular standard deviation (LVSD and RVSD, respectively) and interventricular mechanical delay (IVMD), the absolute difference of mean phase angles of right and left ventricle, were computed and expressed in milliseconds. Mean + 3 standard deviation (SD) was used to derive the cut-off limits. Average LVEF and duration of cardiac cycle in the study group were 62.5%±5.44% and 868.9±114.5 msec, respectively. The observations of LVSD, RVSD and right and left ventricular mean phase angles were shown to be normally distributed by Shapiro-Wilk test. Cut-off limits for LVSD, RVSD and IVMD were calculated to be 80 msec, 85 msec and 75 msec, respectively. Fourier phase analysis on ERNV is an effective tool for the evaluation of synchronicity of cardiac contraction. The cut-off limits of parameters of dyssynchrony can be used to separate heart failure patients with cardiac dyssynchrony from those without. ERNV can be used to select patients for cardiac resynchronization therapy. (author)

  10. Evaluation of coronary artery disease by functional imaging from equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    He Zuoxiang

    1992-01-01

    Functional imagings were performed in 10 normals, 9 subjects with Non coronary Artery disease (NCAD), 33 CAD patients with documented MI (CAD-WMI) and 20 without MI (CAD-NMI). The sensitivity of LVGEF, LVREF and phase analysis at rest for detecting CAD-WMI was 66.7%, 78.8%, 93.9% respectively. LVGEF, LVREF during exercise for assessing CAD-NMI had the sensitivity of 90%, 80%, respectively, while specificity 90%. Early LVEF decrease, > 10% LVEF decrease and abnormal response at > 7 sectors during exercise were observed in 2 patients with 3 vessel. In conclusion, functional imaging were very useful for detecting CAD and evaluating its extent

  11. Clinical assessment of patients with mitral valve prolapse syndrome using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Ochiai, Masakazu; Shirayama, Takeshi; Otsuki, Katsuichi; Adachi, Haruhiko; Nakagawa, Masao.

    1995-01-01

    Left ventricular performance in patients with mitral valve prolapse syndrome (MVP) was evaluated and compared with that in patients with ischemic heart diseases (IHD), consisting of angina pectoris (AP) and old myocardial infarction (OMI). Left ventricular ejection fraction (LVEF) and peak ejection rate (PER) were used as indices of systolic function. Peak filling rate (PFR), filling fraction in the first third of diastole (1/3FF) and time to peak filling (TPF) were used as indices of diastolic function. At rest, LVEF and PER were significantly larger in the MVP group than those in the OMI group. PFR and TPF were shown better diastolic functions in the MVP group than those in the AP or OMI groups. During stress testing, the LVEF of the MVP group increased during exercise, whereas that of the IHD group decreased gradually to the downward response (exercise-induced ischemia). The PFR of the MVP group curved upward during exercise in contrast with the inconstant response of the IHD group. We conclude that chest pain and various symptom in patients with MVP are unrelated to IHD. (author)

  12. Cardiac ventriculography

    International Nuclear Information System (INIS)

    Hillis, L.D.; Grossman, W.

    1986-01-01

    Cardiac ventriculography has been used extensively to define the anatomy of the ventricles and related structures in patients with congenital, valvular, coronary, and cardiomyopathic heart disease. Specifically, left ventriculography may provide valuable information about global and segmental left ventricular function, mitral valvular incompetence, and the presence, location, and severity of a number of other abnormalities, including ventricular septal defect and hypertrophic cardiomyopathy. As a result, it should be a routine part of catheterization in patients being evaluated for coronary artery disease, aortic or mitral valvular disease, unexplained left ventricular failure, or congenital heart disease. Similarly, right ventriculography may provide information about global and segmental right ventricular function and can be especially helpful in patients with congenital heart disease

  13. The blood-pool technique of radionuclide ventriculography: Data acquisition and evaluation

    International Nuclear Information System (INIS)

    Mueller-Schauenburg, W.

    1986-01-01

    For gated heart studies an in-vitro-labelling of erythrocytes is commonly used. Rest and exercise studies are acquired from LAO. Complementary studies may have different views. Besides the most common direct frame mode acquisition, there are the more flexible list mode and a hybrid mode. Concerning evaluation the ejection fraction is the leading parameter of global ventricular analysis. In local analysis a pixelwise evaluation generates functional images of phases and amplitudes (the Fourier approach developed by the Ulm group) or Noelep's trend images. Special attention has to be paid to the varying cycle length when a sine or cosine fitting (Fourier) is used for curve smoothing or phase and amplitude images. There are two opposed problems: If there are undetected QRS-complexes, the end of the representative cycle will contain early phases of subsequent cycles which must be cut off. In the case of really varying cycle length, the last images of the representative cycle must be corrected for acquisition time per frame. The total count curve may help to discriminate both cases and supplies suitable correction factors in the latter case. (orig.) [de

  14. Factor analysis of radionuclide ejection fraction response during exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Yamamuro, Masashi

    1986-01-01

    In 204 patients with ischemic heart disease and 25 normal subjects who underwent exercise radionuclide ventriculography (RNV), multivariate analyses and other statistical methods were employed to study factors affecting changes in left ventricular ejection fraction (ΔEF). Twenty one variables were obtained from clinical diagnosis, cardiac catheterization, and RNV. Multivariate analyses showed that coronary score for the severity of coronary artery lesions was the most significant factor, followed by exercise duration, resting heart rate, the number of diseased vessels, and exercise heart rate. Statistically significant decrease in ΔEF was associated with regional wall motion abnormality, ECG changes, and chest pain. Lesions in the left main trunk and the proximal area of left anterior descending artery were greatly involved in the decrease of ΔEF. (Namekawa, K.)

  15. Right and left ventricular cardiac function in a developed world population with human immunodeficiency virus studied with radionuclide ventriculography

    DEFF Research Database (Denmark)

    Lebech, Anne-Mette; Gerstoft, Jan; Hesse, Birger

    2004-01-01

    . No correlations were found between reduced cardiac function and levels of the 3 peptides measured. CONCLUSIONS: No major dysfunction of the left ventricle is present in a developed world HIV population. However, a small but significant part of this population has modestly reduced right-sided systolic function.......-associated morbidity and mortality rates. Accordingly, the prevalence of HIV-associated cardiac dysfunction may also have changed. The aim of the study was to establish the prevalence of right- and left-sided cardiac dysfunction in a Danish HIV population, most of whom were undergoing HAART, with radionuclide...... ventricular ejection fraction and 6 (7%) had a reduced right ventricle ejection fraction (0.35-0.42) compared with reference values from the age- and sex-matched reference population. Patients with HIV and reduced cardiac function did not differ in the duration of HIV, CD4 count, CD4 nadir, or HIV RNA load...

  16. Exercise radionuclide ventriculographic study of mitral stenosis before and after percutaneous mirtal valvuloplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Shim, Won Heum; Cho, Seung Yun; Kim, Sung Soon; Lee, Woong Ku; Kim, Myeong Jin; Choe, Kyu Ok [Yonsei University, College of Medicine, Seoul (Korea, Republic of); Park, Seung Jung [Asan Medical Center, College of Medicine, University of Ulsan, Seoul (Korea, Republic of)

    1992-11-15

    We performed radionuclide ventriculography before and within 1 week after percutaneous mirtal valvuloplasty (PMV) to evaluate left ventricular (LV) function in 20 patients (2 meals and 17 females, mean age of 38 {+-} 10 years) who were pure mitral stenosis before PMV and less than grade 1 mirtal regurgitation developed after PMV. 9 out of 20 patients had atrial fibrillation and 3 patients developed a small left-to-right shunt (Qp/Qs < 1.5) after PMV. PMV using double-balloon technique resulted in a increase in mitral valve area (0.9 {+-} 0.3 to 2.1 {+-} 0.8cm{sup 2}, {rho} < 0.001) and in rest cardiac output (4.2 {+-} 1.0 to 4.8 {+-} 1.4 L/min, {rho} < 0.005). And also a decrease in mean mitral gradient (16.2 {+-} 7.0 to 5.2 {+-} 3.0 mmHg, {rho} < 0.001) was noted. Comparisons of LV function by supine bicycle exercise radionuclide ventriculography before and after PMV showed no significant changes in rest LV ejection fraction (LVEF, 55.2 {+-} 9.7 to 56.1 {+-} 11.0%, {rho} > 0.05), maximal exercise LVEF (60.9 {+-} 10.3 to 59.3 {+-} 11.1%, {rho} > 0.05), peak ejection rate (2.02 {+-} 0.58 to 2.15 {+-} 0.60 EDV/ses, {rho} > 0.05), and peak filling rate (1.04 {+-} 0.55 to 1.52 {+-} 0.49 EDV/ses, {rho} > 0.05). However, LV end diastolic volume (LVEDV, -29.3 {+-} 19.0 to +3.3 {+-} 32.9%, {rho} < 0.001), stroke volume (SV,-22.0 {+-} 22.0 to +11.2 {+-} 40.0%, {rho} < 0.001), and cardiac output (CO, 64.6 {+-} 54.0 to 100.4 {+-} 69.7%, {rho} < 0.05) with exercise compared to resting values were significantly increased. We conclude that PMV resulted in a significant increase in LVEDV, SV, and CO with exercise, but decreased LV systolic performance and no improvement in diastolic filling.

  17. The acute hemodynamic effects of intravenous verapamil in coronary artery disease. Assessment by equilibrium-gated radionuclide ventriculography

    International Nuclear Information System (INIS)

    Klein, H.O.; Ninio, R.; Oren, V.; Lang, R.; Sareli, P.; DiSegni, E.; David, D.; Guerrero, J.; Kaplinsky, E.

    1983-01-01

    The acute hemodynamic effects of an i.v. bolus of verapamil, 0.1 mg/kg or 0.06-0.075 mg/kg, were examined by serial radionuclide studies in 46 patients with coronary artery disease. In 20 patients with ejection fractions (EFs) greater than 35% (group 1A), verapamil, 0.1 mg/kg given over 1-11/2 minutes, had a biphasic effect: first, a transient decrease in EF accompanied by increased left ventricular (LV) volumes and cardiac output equivalents; then, an overshoot of EF to values above control, accompanied by a decrease in peripheral vascular resistance and a drastic decrease in LV volumes, while cardiac output equivalent remained slightly elevated. In eight patients with EFs less than 35% (group 1B), only the first effect on EF was noted. In 10 patients with EFs greater than 35% (group 2), verapamil, 0.06-0.075 mg/kg, exerted qualitatively similar but milder effects on hemodynamic function. Finally, verapamil, 0.1 mg/kg given more slowly, over 2-21/2 minutes, produced no significant changes in EF or LV volumes in another eight patients (group 3). The acute effects of verapamil are thus both time-related and dose-dependent. They are also related to the baseline functional reserve of the left ventricle. This study documents that verapamil exerts a depressant effect on LV function. However, the transient nature of this depression and the quick recovery to normal or above-normal values indicate that verapamil, in the doses used in this study, is safe to use intravenously in patients with coronary artery disease

  18. Dual-ROI radionuclide ventriculography

    International Nuclear Information System (INIS)

    Standke, R.; Hoer, G.; Kanemoto, N.; Maul, F.D.

    1981-01-01

    Accurate determination of the left ventricular activity function is the precondition for a quantitative analysis of the ventricular volume function. During the volume reduction period, extra-myocardial tissue penetrates into the ROI of the late diastole. This curve-distorting activity cannot be eliminated by a single-ROI technique. Of the multiple-ROI techniques, the dual-ROI method is the least complex and tedions and involves the least methodological error. At the time of maximum volume change rates, the curve may be distorted if the late diastolic ROI is inaccurately defined. A method is described which uses only the counting rate over the late diastolic ROI and corrects it only on the basis of the counting rate of the late systolic ROI. The time parameters remain uninfluenced by this correction method while the volumetric parameters are corrected. (orig./APR) [de

  19. Scintigraphic ventriculography and stress testing

    International Nuclear Information System (INIS)

    Goris, M.L.; Hung, J.; Debusk, R.F.

    1982-01-01

    Scintigraphic stress ventriculography yields information which is complex and defies description by the difference in ejection fraction between rest and maximum exercise only. The complexity results in part from the ''derived'' nature of the ejection fraction measurement, which is physiologically secondary to stroke volume and end-diastolic volume. Furthermore, the nature of the stress test in which the pulse (stress) is not independent from the response forces an analysis which considers ''when'' as much as ''what'' happens. Automation in data processing, however, has made oversimplification unnecessary and allows a more exhaustive but correct analysis

  20. Serial exercise gated radionuclide ventriculograms (RVG) in monitoring doxorubicin cardiotoxicity

    International Nuclear Information System (INIS)

    Goldstein, H.A.; Lahoda, J.; Fox, L.

    1985-01-01

    The resting RVG (Radionuclide Ventriculograms) are demonstrated to be an effective monitor of the cardiotoxicity of doxorubicin. The exercise RVG has not been as well studied to see if it yields additional information or detects toxicity effects earlier. Sixteen patients receiving doxorubicin for chemotherapy had 2-6 serial exercise studies with intervals between studies of 1 month to 15 months. The patients exercised varying amounts with cardiac work indicated by their double products (HR x Sys. BP). Although all patients started with a normal resting LVEF (>50%), 5 of the 16 did not have a normal response (≥5% increase in LVEF) with initial exercise study. Of the 11 patients with an initially normal response to exercise, on at least one subsequent study, 3 had an abnormal response to exercise. On a later follow up study 1 of these 3 patients again had a normal response to exercise. Six of these 11 patients had had RVG evidence of cardiotoxicity. Four of these 6 patients had continually normal exercise responses, while 2 of these 5 patients had had an abnormal exercise response. An initial exercise RVG may be reasonable to detect unsuspected CAD in cancer victims. These patients are reported to be more sensitive to the toxic effects of doxorubicin. Follow up exercise RVGs do not contribute useful information, do not predict cardiotoxicity, and may be misleading

  1. Radionuclide exercise testing for coronary artery disease

    International Nuclear Information System (INIS)

    Beller, G.A.

    1984-01-01

    It is obvious that the indication and clinical applications of radionuclide stress testing have been expanded and that both techniques described in this article are useful for diagnostic and prognostic purposes. The sensitivity and specificity of noninvasive stress testing have been significantly enhanced by the introduction of these radionuclide approaches for detecting ischemia in patients with undiagnosed chest pain. High-risk patients with either stable CAD or recent myocardial infarction can be identified by the severity of the abnormal response elicited. Patients with multiple thallium defects, particularly of the redistribution type, appear to be at the highest risk for subsequent cardiac events. Similarly, patients with a greater than 10 per cent fall in ejection fraction with development of multiple wall motion abnormalities and an increase in end-systolic volume seem to be in a high risk subset. Further developments with single photon emission tomography and computer quantitation of thallium or ventriculographic images should make these tests even more reliable in obtaining useful information in patients with CAD. 34 references

  2. Prognostic value of echocardiography in 190 patients with chronic congestive heart failure. A comparison with New York Heart Association functional classes and radionuclide ventriculography

    DEFF Research Database (Denmark)

    Madsen, B K; Videbaek, R; Stokholm, H

    1996-01-01

    Survival in 190 consecutive patients with congestive heart failure, discharged from a general hospital, was studied. Sixteen patients were in New York Heart Association (NYHA) class I, 87 in II, 83 in III and 4 in IV. Median left ventricular ejection fraction (LVEF) from radionuclide...

  3. Use of phase images in radionuclide ventriculography for topical diagnosis of the Wolff-Parkinson-White syndrome and sources of abnormal rhythms in the ventricles

    International Nuclear Information System (INIS)

    Ostroumov, E.N.; Sergienko, V.B.; Golitsin, S.P.

    1990-01-01

    The paper presents the results of the mapping of various types of the Wolff-Parkinson-White syndrome and ventricular arrhythmias by using phase images of radionuclide ventriculograms as compared to 12 leads and electrophysiological studies. Phase images are a highly informative method that supplements an electrophysiological study in the topical diagnosis of abnormal tracts and ventricular arrhythmias

  4. Radionuclide determination of right and left ventricular stroke volumes

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wei Feng; Roubin, G S; Choong, C Y.P.; Harris, P J; Flether, P J; Kelly, D T; Uren, R F; Hutton, B F

    1985-03-01

    The relationship between radionuclide and thermodilution measurement of stroke volumes (SV) was investigated in 30 patients without valvular regurgitation or intracardiac shunt (group A) at rest and during exercise. Both attenuated radionuclide right ventricular (RV) and left ventricular (LV) SV measurements correlated well with the SV determined by the thermodilution method (r = 0.87 and r = 0.93, all P < 0.001). The reliability of the radionuclide method to estimate SV was evaluated prospectively in two additional groups of patients. In 11 patients without valvular regurgitation or intracardiac shunt (group B) the radionuclide RVSV and LVSV closely approximated to thermodilution SV at rest and during exercise. In 15 patients with aortic regurgitation (group C) the radionuclide stroke volume ratio correlated well with the angiographic regurgitant fraction. Thus, both RVSV and LVSV and the severity of aortic regurgitation can be reliably measured with gated radionuclide ventriculography.

  5. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  6. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  7. An intercomparison exercise on radionuclides in sediment samples

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, S.P.

    1996-07-01

    An intercomparison exercise on artificial and natural radionuclides in two sediment samples, one from the Baltic Sea and one from the Kattegat, has been carried out under the EKO-1 project or the Nordic Safety Research Programme (NKS) for the period 1996-97. The measurement techniques have included direct gamma-ray spectrometry with Ge and NaI detectors, and radiochemical procedures followed by beta counting and alpha spectrometry. The participants have 21 laboratories. Results were submitted for Cs-137, Cs-134, Co-60, Sb-125, Pu-239,240, Pu-238, Am-241, Sr-90, Ra-226, Th-232 and K-40, Pb-210, Po-210 and U-235. The analytical performance of the participants was evaluated for those radionuclides where six or more data sets were received. Statistical tests were made to see if individual results agreed with overall average radionuclide concentrations in the two sediment materials within target standard deviations. The results of these tests show that for Cs-137, Cs-134, Ra-226, Th-232 and K-40 the analytical performance criteria were not met for 20-40% of the data sets. For plutonium isotopes the tests show that the performance criteria were not met for 13% of the data sets. Tests of overall analytical performance show that 61% of the data sets do not meet the combined performance criteria. This shows that there is room for considerable improvement of analytical quality for most of the laboratories that have participated in this intercomparison. The intercomparison exercise has furthermore demonstrated several elementary problems in analytical work. (au) 57 tabs., 16 ills., 1 ref.

  8. An intercomparison exercise on radionuclides in sediment samples

    International Nuclear Information System (INIS)

    Nielsen, S.P.

    1996-07-01

    An intercomparison exercise on artificial and natural radionuclides in two sediment samples, one from the Baltic Sea and one from the Kattegat, has been carried out under the EKO-1 project or the Nordic Safety Research Programme (NKS) for the period 1996-97. The measurement techniques have included direct gamma-ray spectrometry with Ge and NaI detectors, and radiochemical procedures followed by beta counting and alpha spectrometry. The participants have 21 laboratories. Results were submitted for Cs-137, Cs-134, Co-60, Sb-125, Pu-239,240, Pu-238, Am-241, Sr-90, Ra-226, Th-232 and K-40, Pb-210, Po-210 and U-235. The analytical performance of the participants was evaluated for those radionuclides where six or more data sets were received. Statistical tests were made to see if individual results agreed with overall average radionuclide concentrations in the two sediment materials within target standard deviations. The results of these tests show that for Cs-137, Cs-134, Ra-226, Th-232 and K-40 the analytical performance criteria were not met for 20-40% of the data sets. For plutonium isotopes the tests show that the performance criteria were not met for 13% of the data sets. Tests of overall analytical performance show that 61% of the data sets do not meet the combined performance criteria. This shows that there is room for considerable improvement of analytical quality for most of the laboratories that have participated in this intercomparison. The intercomparison exercise has furthermore demonstrated several elementary problems in analytical work. (au) 57 tabs., 16 ills., 1 ref

  9. Physical aspects of nuclear ventriculography

    International Nuclear Information System (INIS)

    Alpert, N.M.; Chesler, D.A.; Burnham, C.A.; McKusick, K.A.; Pohost, G.; Dinsmore, R.E.; Brownell, G.L.

    1976-01-01

    The use of edge enhancement and computer motion display improves the detection of regional wall motion abnormalities in the LV. Improved gating and processing techniques should improve the accuracy of ventricular volume vs time measurements. It is hoped that the simulations described will aid in the development of new instrumentation for the collection and analysis of nuclear ventriculographie data

  10. Prognostic value and limitations of exercise radionuclide angiography in medically treated coronary artery disease

    International Nuclear Information System (INIS)

    Taliercio, C.P.; Clements, I.P.; Zinsmeister, A.R.; Gibbons, R.J.

    1988-01-01

    We investigated whether exercise radionuclide angiography provides prognostic information in addition to that identified by resting left ventricular function and coronary anatomy in patients with medically treated coronary artery disease. Clinical follow-up (median, 21.7 months) was obtained in 424 medically treated patients who underwent exercise radionuclide angiography and coronary angiography. The mean age of the study population was 58 years, and 67% were men. Cardiac death occurred in 16 patients, nonfatal myocardial infarction in 16, and nonfatal out-of-hospital cardiac arrest in 1. Univariate analysis showed that multiple variables were associated with future cardiac events, including number of diseased vessels, exercise and rest radionuclide ejection fraction, history of myocardial infarction, exercise and rest left ventricular end-systolic and end-diastolic volume indices, peak exercise workload, age, abnormal resting electrocardiogram, and peak exercise ST-segment depression. Only three variables were independently associated with cardiac events on follow-up: number of diseased vessels, radionuclide ejection fraction at rest, and age. In patients with three-vessel disease and a resting radionuclide ejection fraction of more than 40%, a subgroup with higher risk could not be identified on the basis of exercise radionuclide response

  11. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  12. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  13. A quality control exercise of radionuclide calibrators among Belgian hospitals

    International Nuclear Information System (INIS)

    Reher, D.F.G.; Merlo, P.

    1990-01-01

    On the initiative of the Belgian Association of Hospital Physicists, eleven Belgian hospitals participated in a quality control of radionuclide calibrators conducted in collaboration with the Central Bureau for Nuclear Measurements of the Commission of the European Communities. For practical reasons the nuclide 57 Co was chosen. The results from 20 different radionuclide calibrators show a fair agreement with a similar comparison carried out in 1980 in the UK. (orig.)

  14. Detection of coronary artery disease - comparison of exercise stress radionuclide angiocardiography and thallium stress perfusion scanning

    International Nuclear Information System (INIS)

    Jengo, J.A.; Freeman, R.; Brizendine, M.; Mena, I.; St. Mary Medical Center, Long Beach, Calif.)

    1980-01-01

    Exercise thallium scanning and stress radionuclide angiography were compared in 16 normal subjects and 42 patients with more than 75% coronary arterial obstruction in studies using upright exercise on a bicycle ergometer. Studies at rest were subsequently obtained. Exercise thallium scans in the control group were normal in 15 and showed a defect in 1. Ejection fraction increased in all 16. During exercise, regional wall motion increased uniformly. In the group with coronary artery disease, thallium scanning revealed a new defect in the distribution of the involved arteries in 24 patients. In 15 who had a defect at rest, no new defect developed, but in 9 of the 15 new segmental wall motion defects were evident on radionuclide angiography. With exercise, ejection fraction decreased slightly. Regional wall motion abnormalities developed in the areas corresponding to thallium defects in all. Thallium scanning had a 93% and radionuclide angiography a 98% sensitivity value in detecting coronary artery disease. The respective specificity values were 94 and 100%. In patients with prior myocardial infarction who manifested new exercise abnormalities, 50% showed new thallium defects and 81% new wall motion defects

  15. Rest and exercise radionuclide angiography for diagnosis in chronic ischemic heart disease

    International Nuclear Information System (INIS)

    Gibbons, R.J.

    1991-01-01

    Rest and exercise radionuclide angiography is frequently employed for the diagnosis of chest pain syndromes. Its value and limitations in this regard have been well studied, but proper utilization of the technique requires an understanding of five critical concepts: (1) Radionuclide angiography is superior to treadmill exercise testing and probably equivalent to thallium scintigraphy, although the published series did not use current methods. (2) The true specificity of radionuclide angiography is about 80%, intermediate between the early optimistic estimates and the later pessimistic ones. (3) The peak exercise ejection fraction is the preferred test parameter for diagnosis, although exercise hemodynamics, symptoms, and electrocardiographic changes should also be considered. (4) Although radionuclide angiography is clearly helpful for noninvasive diagnosis, significant numbers of patients will continue to fall in an uncertain category. (5) The proper application of the technique requires recognition of its limitations and careful attention to technical details. When properly applied, this modality can make an important contribution to clinical decision making. 58 references

  16. Quantitative analysis of cardiac function: Comparison of electrocardiogram dual gated single photon emission tomography, planar radionuclide ventriculogram and contrast ventriculography in the determination of LV volume and ejection fraction

    Energy Technology Data Exchange (ETDEWEB)

    Ziada, G.; Abdel-Dayem, H.M.; Higazy, E.; Mohamed, M.M.; Bahar, R.; Hayat, N.; Yousof, A.M.

    1987-03-01

    A dual gated tomography (DGT) program for end systolic and end diastolic acquisition and subsequent processing for calculation of LVEF, end diastolic and end systolic volumes (EDV, ESV) has been evaluated in 20 healthy volunteers (25 years-40 years) and 45 patients (25 years-60 years): 20 with ischaemic heart disease and 25 with valvular heart disease (VHD). All had biplane multigated blood pool (MUGA) studies in the 40/sup 0/ LAO projection using in vivo /sup 99m/Tc-R BCs, immediately followed by DG. The results in the patients group were correlated with contrast ventriculography (CV). In the volunteer group, the normal values for LVEF, EDV and ESV measured with DGT were found to be 63%+10%, 91 ml + 6 ml and 30 ml + 6ml and r value for the LVEF=0.91 compared with MUGA. In the IHD group, r values compared with CV were 0.915 and 0.97 for the EDV and ESV and 0.934 for the LVEF. Compared with the MUGA, the r value for LVEF was 0.883. In the VHD group, r values were 0.98 for both the EDV and ESV and 0.948 for the LVEF (P<0.002) compared with CV and 0.789 for the LVEF compared with the MUGA. We feel that DGT is an accurate and reproducible technique for LV function measurements.

  17. Response of left ventricular volume to exercise in man assessed by radionuclide equilibrium angiography

    International Nuclear Information System (INIS)

    Slutsky, R.; Karliner, J.; Ricci, D.; Schuler, G.; Pfisterer, M.; Peterson, K.; Ashburn, W.

    1979-01-01

    To assess the effects of exercise on left ventricular volumes we studied 10 normal men, 15 patients with coronary disease who developed angina pectoris during exercise, and 10 patients with known coronary disease who did not develop angina during exercise. Each subject performed supine bicycle exercise under a mobile, single-crystal scintillation camera until angina or fatigue occurred. Technetium-99m bound to human serum albumin was the imaging agent. Data were collected at rest and during the last 2 minutes of each 3-minute stage of exercise and for 10 minutes after exercise. Volumes were calculated by a new radionuclide technique that correlated well with cineangiography and is expressed in nondimensional units. In normal subjects, the end-diastolic volume (EDV) at rest was not different from that a peak exercise. The end-systolic volume (ESV) decreased at peak exercise. ESV decreased progressively in all but two of 30 exercise periods. Angina patients had a larger EDV at rest and during chest pain than normals. Angina patients increased their ESV during chest pain resulting in a decreased ejection fraction (EF). All angina patients had a higher ESV during chest pain than during the exercise stage before chest pain. As a group, patients who did not develop angina had a lower EDV at rest and peak exercise than those who did develop angina. We conclude: that the EF increases during exercise due to a decrease in ESV; that the EF in patients with angina decreases because of an increase in ESV; and that the EF in coronary disease patients without angina shows no change because there is no significant change in the ESV. Radionuclide equilibrium angiography may prove useful for assessing EF and volume changes in patients with coronary artery disease

  18. GHSI emergency radionuclide bioassay laboratory network - summary of the second exercise

    International Nuclear Information System (INIS)

    Li, Chunsheng; Ko, Raymond; Quayle, Debora; Sadi, Baki; Bartizel, Christine; Battisti, Paolo; Boettger, Axel; Bouvier, Celine; Paquet, Francois; CapoteCuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L.; Kim, Eunjoo; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Rulik, Petr; Sergei, Aleksanin; Sierra, Inmaculada; Oliveira Sousa, Wandersonde; Szabo, Gyula

    2017-01-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides ( 90 Sr, 106 Ru, 137 Cs, and 239 Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. (authors)

  19. Effects of upright and supine position on cardiac rest and exercise response in aortic regurgitation.

    Science.gov (United States)

    Shen, W F; Roubin, G S; Fletcher, P J; Choong, C Y; Hutton, B F; Harris, P J; Kelly, D T

    1985-02-01

    The effects of upright and supine position on cardiac response to exercise were assessed by radionuclide ventriculography in 15 patients with moderate to severe aortic regurgitation (AR) and in 10 control subjects. In patients with AR, heart rate was higher during upright exercise, but systolic and diastolic blood pressure and left ventricular (LV) output were similar during both forms of exercise. LV stroke volume and end-diastolic volume were not altered during supine exercise. LV end-systolic volume increased and ejection fraction decreased during supine exercise, but both were unchanged during upright exercise. Of 15 patients, 5 in the upright and 12 in the supine position had an abnormal LV ejection fraction response to exercise (p less than 0.01). Right ventricular ejection fraction increased and regurgitant index decreased with both forms of exercise and was not significantly different between the 2 positions. Thus, posture is important in determining LV response to exercise in patients with moderate to severe AR.

  20. Right-ventricular and left-ventricular function parameters in patients with and without outflow tract patches as determined by radionuclide methods at least 10 years following surgical correction of Fallot's tetralogy in the adult individuals

    International Nuclear Information System (INIS)

    Seidel, P.

    1988-01-01

    During a period starting in 1983 and ending in April 1984 radionuclide ventriculography was performed in 26 patients subjected to surgical correction of Fallot's tetralogy after having reached adulthood. They were divided into two groups according to the surgical methods used. Patients showing no right-ventricular outflow patch were assigned to group I, while group II was made up of individuals that had received outflow tract patches of Dacron or Teflon for pressure reduction in the right ventricle. The parameters registered during radionuclide ventriculography, in which the tracer substance TC 99m was administered into a peripheral vein, included the endiastolic volume, endsystolic volume, stroke volume, global ejection fraction and cardiac index. For resting patients, these values were calculated using the first-pass technique, the determinations during exercise on the ergometer were based on equilibrium radionuclide ventriculography. It could be concluded from the results obtained here that non-invasive endocardial scintigraphy is a sensitive method that can be used both at rest and during exercise on the ergometer to detect function disorders of the right and left ventricles. (orig./MG) [de

  1. Radionuclide observables during the Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty

    International Nuclear Information System (INIS)

    Burnett, Jonathan L.; Miley, Harry S.; Milbrath, Brian D.

    2016-01-01

    In 2014 the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) undertook an Integrated Field Exercise (IFE14) in Jordan. The exercise consisted of a simulated 0.5–2 kT underground nuclear explosion triggering an On-site Inspection (OSI) to search for evidence of a Treaty violation. This research paper evaluates two of the OSI techniques used during the IFE14, laboratory-based gamma-spectrometry of soil samples and in-situ gamma-spectrometry, both of which were implemented to search for 17 OSI relevant particulate radionuclides indicative of nuclear explosions. The detection sensitivity is evaluated using real IFE and model data. It indicates that higher sensitivity laboratory measurements are the optimum technique during the IFE and within the Treaty/Protocol-specified OSI timeframes. - Highlights: • The 2014 Integrated Field Exercise occurred in Jordan. • The detection sensitivity for two On-site Inspection techniques was evaluated. • The techniques search for 17 particulate radionuclides indicative of nuclear explosions. • Laboratory-based gamma-spectrometry of soil samples was the optimum technique.

  2. Determination of Natural Levels of Radionuclides in Proposed Mushroom Reference Material (A Proficiency Test Exercise)

    International Nuclear Information System (INIS)

    Waheed, S.; Rahman, A.; Siddique, N.; Ahmad, S.; Zaidi, J.H.

    2006-08-01

    A proficiency test (PT) was organized within the framework of international Atomic Energy Agency (IAEA) project INT/1/054, entitled 'Preparation' of Reference Materials and Organization of Proficiency Test Rounds'. This exercise served to estimate the proficiency of the analytical laboratories from participating countries. This report presents the results of the proficiency test exercise on the proposed Mushroom Reference Material for the determination of natural levels of radionuclides. Laboratories from 6 different countries submitted data on the following three radionuclides: /sup 134/Cs, /sup 137/Cs, /sup 40/K. Results for /sup 134/Cs, 137/sup 137/Cs, and /sup 40/K in the mushroom reference material were reported by three or more participating laboratories and could be subjected to statistical evaluation. The original data of these raionuclides was subjected to a computer program 'Histo Vession 2.1' provided by IAEA. The four outlier tests i.e. Dixon, Grubbs, Skewness and Kurtosis were applied to the data sets. All values for these three radionuclides were accepted by the software. Consensus (overall) mean value, absolute standard deviation, relative standard deviation, standard error, median and range of values for these three radionuclides have been are obtained (at significance level 0.05). the consensus mean values and confidence intervals are given./sup 134/Cs: 4.4 Bq/kg (3.4-5.3 Bq/kg) /sup 137/Cs: 2899 Bq/kg (2740-3058 Bq/kg) /sup 40/K: 1136 Bq/kg (1046-1226 Bq/kg). (author)

  3. Validation of rest and exercise radionuclide angiography in patients with aortic regurgitation

    International Nuclear Information System (INIS)

    Gosiewska-Marcinkowska, E.; Rawczynska-Englert, I.; Szumilak, B.; Konieczna, S.; Rozycka-Chrzanowska, B.

    1992-01-01

    The aim of the study was to evaluate the significance of rest and stress test using radionuclide angiography (RA) in assessment of left ventricular (LV) function in the patients with aortic regurgitation (AR). In 32 patients we analyzed pre and 12 months after aortic valve replacement (AVR) the clinical data (including LV cavity dimension, LV hypertrophy, relative heart volume - RHV, the value of diastolic pressure) and the RA at rest and during supine stress test. We compared the clinical data with eject fraction (EF) and rest (EFr), at exercise (EFex) and ΔEF=EFex-EFr. Results show good correlation between clinical data and EF. Conclusions: 1) exercise RA is an useful method of estimation of LV function and after AVR; 2) early evaluation of the reserve of the LV allows to establish the appropriate time for AVR even before the signs of insufficiency of the LV are revealed. (author). 8 refs, 2 tabs

  4. Radionuclide observables during the Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty.

    Science.gov (United States)

    Burnett, Jonathan L; Miley, Harry S; Milbrath, Brian D

    2016-03-01

    In 2014 the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) undertook an Integrated Field Exercise (IFE14) in Jordan. The exercise consisted of a simulated 0.5-2 kT underground nuclear explosion triggering an On-site Inspection (OSI) to search for evidence of a Treaty violation. This research paper evaluates two of the OSI techniques used during the IFE14, laboratory-based gamma-spectrometry of soil samples and in-situ gamma-spectrometry, both of which were implemented to search for 17 OSI relevant particulate radionuclides indicative of nuclear explosions. The detection sensitivity is evaluated using real IFE and model data. It indicates that higher sensitivity laboratory measurements are the optimum technique during the IFE and within the Treaty/Protocol-specified OSI timeframes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Radionuclide cardiography in medical practice

    International Nuclear Information System (INIS)

    Strangfeld, D.; Mohnike, W.; Schmidt, J.; Heine, H.; Correns, H.J.

    1986-01-01

    This publication is a compendium on all aspects of radionuclide diagnostics concerning cardiovascular system diseases. Starting with introductory remarks on the control of cardiovascular diseases the contribution of radionuclide cardiology to functional cardiovascular diagnostics as well as pathophysiological and pathobiochemical aspects of radiocardiography are outlined. Radiopharmaceuticals used in radiocardiography, physical and technical problems in application of radionuclides and their measuring techniques are discussed. In individual chapters radionuclide ventriculography, myocardial scintiscanning, circulatory diagnostics, radionuclide diagnostics of arterial hypertension, of thrombosis and in vitro diagnostics of thrombophilia are treated in the framework of clinical medicine

  6. Right and left ventricular ejection fraction at rest and during exercise assessed with radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Dahlstroem, J.A.

    1982-01-01

    Right (RVEF) and left ventricular ejection fraction (LVEF) assessed with radionuclide angiocardiography were compared to simultaneously obtained catheterization results at rest and during exercise in patients with pulmonary hypertension and ischemic heart disease. Blood pool imaging was performed with red blood cells (RBC) labelled with 99 Tcsup(m) in vivo as this method gave more stable 99 Tcsup(m) levels in blood compared to 99 Tcsup(m)-labelled human serum albumin and because it was more convenient than labelling RBC in vitro. RVEF measured with first pass (FP) technique and equilibrium (EQ) technique correlated well at rest, r = 0.86, and during exercise, r = 0.91. The FP technique had the best reproducibility and reference values at rest were 49+-5 per cent increasing with exercise. When 99 Tcsup(m) and 133 Xe were compared to assess RVEF with FP technique, the correlation was good, r = 0.88. LVEF assessed with EQ technique and a fixed end-diastolic region of interest was very reproducible at rest and during exercise; reference values at rest were 56+-8 per cent increasing with exercise. In 10 patients with pulmonary hypertension significant negative correlations were found between RVEF assessed with FP technique and pressures in pulmonary artery and right atrium. Abnormal RVEF was found in all patients with right ventricular disfunction. In 22 patients with recent myocardial infarction measurements of LVEF detected left ventricular disfunction better than did measurement of pulmonary artery diastolic pressure. During effort angina in another 10 patients all had abnormal LVEF and abnormal hemodynamics. By combining ejection fraction and stroke volume, ventricular volumes were calculated at rest and during exercise. (author)

  7. Radionuclide angiographic evaluation of left ventricular performance at rest and during exercise in patients with aortic regurgitation

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Heo, J.

    1986-01-01

    Radionuclide angiographic evaluation of LV performance at rest and during exercise in patients with AR have shown that an abnormal EF response to exercise may be observed in asymptomatic patients with normal resting LV function. The EF response to exercise has been correlated with a number of clinical and exercise measurements; important among these are the slope of the systolic pressure-to-end-systolic volume, end-systolic volume, cardiac index, pulmonary capillary wedge pressure, and wall stress. The changes in the regurgitant fraction, EF, and LV volume have shown considerable individual variability; they have also allowed a better understanding of the circulatory responses during exercise. Radionuclide angiography provides a reliable and reproducible method of measuring the rest LVEF that is important in the timing and the outcome of valve replacement. The value of the EF response to exercise in patient management is not yet clear; it is possible that other radionuclide-derived measurements at rest or during exercise, such as the systolic pressure-to-end-systolic volume relationship, and the end-systolic volume may provide complementary information to that provided by the EF

  8. Right-ventricular and left-ventricular function parameters in patients with and without outflow tract patches as determined by radionuclide methods at least 10 years following surgical correction of Fallot's tetralogy in the adult individuals. Nuklearmedizinische Bestimmung der rechts- und linksventrikulaeren Funktionsparameter von Patienten ohne und mit Ausflusstraktpatch - mindestens 10 Jahre nach operativer Korrektur der Fallot'schen Tetralogie im Erwachsenenalter

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, P.

    1988-12-15

    During a period starting in 1983 and ending in April 1984 radionuclide ventriculography was performed in 26 patients subjected to surgical correction of Fallot's tetralogy after having reached adulthood. They were divided into two groups according to the surgical methods used. Patients showing no right-ventricular outflow patch were assigned to group I, while group II was made up of individuals that had received outflow tract patches of Dacron or Teflon for pressure reduction in the right ventricle. The parameters registered during radionuclide ventriculography, in which the tracer substance TC 99m was administered into a peripheral vein, included the endiastolic volume, endsystolic volume, stroke volume, global ejection fraction and cardiac index. For resting patients, these values were calculated using the first-pass technique, the determinations during exercise on the ergometer were based on equilibrium radionuclide ventriculography. It could be concluded from the results obtained here that non-invasive endocardial scintigraphy is a sensitive method that can be used both at rest and during exercise on the ergometer to detect function disorders of the right and left ventricles. (orig./MG).

  9. Accuracy of diagnosis of coronary artery disease by radionuclide management of left ventricular function during rest and exercise

    International Nuclear Information System (INIS)

    Jones, R.H.; McEwan, P.; Newman, G.E.; Port, S.; Rerych, S.K.; Scholz, P.M.; Upton, M.T.; Peter, C.A.; Austin, E.H.; Leong, K.H.; Gibbons, R.J.; Cobb, F.R.; Coleman, R.E.; Sabiston, D.C. Jr.

    1981-01-01

    Rest and exercise radionuclide angiocardiographic measurements of left ventricular function were obtained in 496 patients who underwent cardiac catheterization for chest pain. Two hundred forty-eight of these patients also had an exercise treadmill test. An ejection fraction less than 50% was the abnormality of resting left ventricular function that provided the greatest diagnostic information. In patients with normal resting left ventricular function, exercise abnormalities that were optimal for diagnosis of coronary artery disease were an injection fraction at least 6% less than predicted, an increase greater than 20 ml in end-systolic volume and the appearance of an exercise-induced wall motion abnormality. The sensitivity and specificity of the test were lower in patients who were taking propranolol at the time of study and in patients who failed to achieve an adequate exercise end point. In the 387 patients with an optimal study, the test had a sensitivity of 90% and a specificity of 58%. Radionuclide angiocardiography was more sensitive and less specific than the exercise treadmill test. The high degree of sensitivity of the radionuclide test suggests that it is most appropriately applied to patient groups with a high prevalence of disease, including those considered for cardiac catheterization

  10. The value of radionuclide phase analysis and parameters of cardial function for diagnosis CAD at rest and during exercise

    International Nuclear Information System (INIS)

    Huang Gang

    1990-01-01

    27 patients and 5 normal were studied with ECG-gated cardial blood pool images and radionuclide phase analysis at rest and during exercise. The results showed that the sensitivity of LVEF in CAD at rest and during exercise were 57% and 71% respectively, and the sensitivity of the ventricular phase in CAD were 79% at rest and 90% during exercise, and the sensitivity of phase angle in CAD were higher than of LVEF. This suggested that the ventricular phase angle was important for diagnosing early CAD. In addition, regional EF, phase image and ventricular wall motion were useful to detect the lesion of ischemia in CAD

  11. Dynamic models for radionuclide transport in agricultural ecosystems: summary of results from a UK code comparison exercise

    International Nuclear Information System (INIS)

    Meekings, G.F.; Walters, B.

    1986-01-01

    In recent years, models have been developed by three organisations in the UK to represent the time-dependent behaviour of radionuclides in agricultural ecosystems. These models were developed largely independently of each other and, in view of their potential applications in relation to radioactive waste management and discharge, the Food Science Division of the Ministry of Agriculture, Fisheries and Food initiated a calculational intercomparison exercise with the agreement and cooperation of all three organisations involved. A subset of the results obtained is reported here. In general a high degree of consistency between the results of the various models was obtained particularly regarding the responses with time. The exercise supported the case for using dynamic models in radiological assessment studies. It also demonstrated areas where differences in results from the models are a consequence of a lack of appropriate data on the environmental behaviour of the radionuclides considered. (author)

  12. Global ejection fraction and phase analysis assessed by radionuclide angiography during exercise and after isoproterenol infusion

    International Nuclear Information System (INIS)

    Righetti, A.; Ratib, O.; Merier, G.; Widmann, T.; Donath, A.

    1983-01-01

    Radionuclide angiography obtained during and following Isoproterenol infusion is a new approach for detecting latent myocardial ischemia. It is very sensitive and could be considered as an alternative to conventional exercice radionuclide angiography. The data presented show that phase analysis assessment of regional systolic wall motion is a better indicator than global ejection fraction for quantifying left ventricular dysfunction

  13. Quantitation of aortic and mitral regurgitation in the pediatric population: evaluation by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Hurwitz, R.A.; Treves, S.; Freed, M.; Girod, D.A.; Caldwell, R.L.

    1983-01-01

    The ability to quantitate aortic (AR) or mitral regurgitation (MR), or both, by radionuclide angiocardiography was evaluated in children and young adults at rest and during isometric exercise. Regurgitation was estimated by determining the ratio of left ventricular stroke volume to right ventricular stroke volume obtained during equilibrium ventriculography. The radionuclide measurement was compared with results of cineangiography, with good correlation between both studies in 47 of 48 patients. Radionuclide stroke volume ratio was used to classify severity: the group with equivocal regurgitation differed from the group with mild regurgitation (p less than 0.02); patients with mild regurgitation differed from those with moderate regurgitation (p less than 0.001); and those with moderate regurgitation differed from those with severe regurgitation (p less than 0.01). The stroke volume ratio was responsive to isometric exercise, remaining constant or increasing in 16 of 18 patients. After surgery to correct regurgitation, the stroke volume ratio significantly decreased from preoperative measurements in all 7 patients evaluated. Results from the present study demonstrate that a stroke volume ratio greater than 2.0 is compatible with moderately severe regurgitation and that a ratio greater than 3.0 suggests the presence of severe regurgitation. Thus, radionuclide angiocardiography should be useful for noninvasive quantitation of AR or MR, or both, helping define the course of young patients with left-side valvular regurgitation

  14. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  15. Digital subtraction ventriculography for assessment of global and regional leftventricular parameters in comparison to conventional contrast ventriculography

    International Nuclear Information System (INIS)

    Eichstaedt, H.; Langer, M.; Felix, R.

    1984-01-01

    Since May 1982 we studied more than 100 patients with heart diseases by means of digital angiography, out of them 46 patients with a history of transmural myocardial infarction were selected. Urografin 76, 30 ml, was administered at a flow rate of 18 ml/s by means of a catheter in the superior vena cava during digital subtraction ventriculography. Results were compared with conventional contrast ventriculograms. The correlation coefficient was r=0.93 (p 0.001) for determination of ejection fraction with both methods. The data in individual cases suggest that DSV is more sensitive than conventional contrast ventriculography in determination of severely reduced ejection fractions. The methods are practically identical in qualitative evaluation of disorders of regional wall motion in the anterolateral region, while DSV is more sensitive than conventional ventriculography in evaluating the apical region. Sensitivity was 85.7% when the two methods were compared in evaluation of the inferior region of the left ventricle. Both methods are identical in demonstration of severely deformed ventricles. Digital subtraction ventriculography may replace conventional contrast ventriculography in some of situations discussed above. (orig.)

  16. Do we need ventriculography in the era of computed tomography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    The question is posed whether in the investigation of intracranial tumors, particularly in the posterior cranial fossa, CT and/or ventriculography should be practiced. We investigated 134 patients (93 were children up to the age of 14 years), all of whom had both computed tomography and ventriculography. The results clearly demonstrate the superiority of CT compared with centriculography. Ventriculography is a surgical intervention with risk for the patient; side effects may occur and serious complications can sometimes arise. Modern CT is producing pictures of high quality which are entirely sufficient for neurosurgical intervention. Very rarely does additional angiography have to be performed. The diagnosis of intracrenial tumor can be fully established by CT and ventriculogrphy is no longer necessary. (orig.)

  17. Radionuclide angiographical assessment of the effects of aorto-coronary bypass grafting on ventricular function during rest and exercise

    International Nuclear Information System (INIS)

    Kito, Yoshitsugu; Fujita, Tsuyoshi; Ohara, Kuniyoshi

    1983-01-01

    Ventricular function was measured by radionuclide angiography during rest and exercise in 27 patients before and after aorto-coronary bypass grafting (AC bypass). The patients were divided in three groups: 6 patients in complete revascularisation (group A), 8 patients in surgical complete revascularisation (group B), and 13 patients in incomplete revascularisation (group C). Heart rate increased by exercise from 58 +- 5 bpm to 87 +- 5 bpm, from 60 +- 5 bpm to 90 +- 15 bpm, and from 61 +- 8 bpm to 84 +- 7 bpm before AC bypass, and increased from 81 +- 7 bpm to 116 +- 11 bpm, from 86 +- 13 bpm to 114 +- 12 bpm, and from 80 +- 11 bpm to 106 +- 13 bpm after AC bypass in group A, B and C, respecitively. EF decreased by exercise from 61 +- 7 % to 58 +- 12 %, from 53 +- 10 % to 49 +- 7 %, and from 54 +- 8 % to 52 +- 8 % before AC bypass, and increased by exercise from 66 +- 7 % to 77 +- 6 %, from 49 +- 11 % to 56 +- 13 %, and from 54 +- 8 % to 59 +- 10 % after AC bypass in group A,FB and C, respectively. dV/dt(Vmax/sec) increased by exercise from 4.0 +- 1.0 to 4.4 +- 1.0, from 2.5 +- 1.0 to 3.4 +- 1.5 and from 3.5 +- 0.5 to 3.4 +- 0.6 before AC bypass, and increased from 3.9 +- 0.5 to 6.2 +- 0.7, from 3.5 +- 0.9 to 5.0 +- 0.7, and from 3.6 +- 1.0 to 5.4 +- 1.5 after AC bypass in group A,B and C, respectively. In conclusion, left ventricular performance during exercise was significantly increased after AC bypass in all patients. However, the rate of increase in left ventricular performance during exercise after AC bypass was more significant in the group of complete revascularisation than in the group of others. Serial application of radionuclide angiography to patients after AC bypass appears promising in evaluating the long-term effects of operation on ventricular function. (author)

  18. Assessment of function of the cardiovascular system in arterial hypertension using radionuclide methods of investigation

    International Nuclear Information System (INIS)

    Oganesyan, N.M.; Babayan, A.S.; Mikaehlyan, R.S.; Mnatsakyan, Eh.L.

    1986-01-01

    Proceeding from a study of the nature of changes in hemodynamics during development of hypertensive disease (HD) at its different stages it was shown that hemodynamic changes in 42.1% of the patients with Stage 1-2A HD were of hypertensive type, in the patients with Stage 2B-3 HD normal and hypokinetic types of the blood circulation prevailed. After bicycle ergometry exercise the reactivity of the cardiovascular system was revealed more completely. The most complete information on function of the cardiovascular system and myocardial contractility can be obtained with the help of radioangiocardiography and radionuclide ventriculography. However in the absence of a gamma-chamber radiocardiography can provide necessary information on function of the cardiovascular system in case it is used in one and the same patient over time using bicycle ergometry testing

  19. Real-time radionuclide cineangiography in the noninvasive evaluation of global and regional left ventricular function at rest and during exercise in patients with coronary-artery disease

    International Nuclear Information System (INIS)

    Borer, J.S.; Bacharach, S.L.; Green, M.V.; Kent, K.M.; Epstein, S.E.; Johnston, G.S.

    1977-01-01

    Although coronary angiography defines regions of potential ischemia in patients with coronary-artery disease, accurate assessment of the presence and functional importance of ischemia requires appraisal of regional and global left ventricular function during stress. To perform such assessment, we developed a noninvasive real-time radionuclide cineangiographic procedure permitting continuous monitoring and analysis of left ventricular function during exercise. In 11 patients with coronary disease who had normal regional and global ventricular function at rest, new regions of dysfunction developed during exercise (P less than 0.001), and in 10, global ejection fraction dropped 7 to 47 percent. Fourteen age-matched normal subjects were studied; during exercise none had regional dysfunction, and each increased global ejection fraction (average increase, 23 +- 3 percent [+-S.E.], P less than 0.001 as compared with patients with coronary disease). Radionuclide cineangiography during exercise permits accurate assessment of the presence and functional severity of ischemic heart disease

  20. Biventricular function in sickle-cell anemia: radionuclide angiographic and thallium-201 scintigraphic evaluation

    International Nuclear Information System (INIS)

    Manno, B.V.; Burka, E.R.; Hakki, A.H.; Manno, C.S.; Iskandrian, A.S.; Noone, A.M.

    1983-01-01

    Left ventricular (LV) and right ventricular (RV) function were evaluated at rest and during exercise using radionuclide ventriculography in 10 patients, aged 19-53 years, with sickle-cell anemia (SCA). Seven patients were in New York Heart Association functional class I and 3 were in class II. The resting LV ejection fraction (EF) was normal in 9 patients and the resting RVEF was normal in 4. LV dilation and high cardiac output were observed in 6 patients at rest. The LVEF during exercise was normal in all 10 patients, whereas only 2 patients had normal RVEF at rest and during exercise. The LVEF was lower in patients with SCA at rest (54 +/- 4% versus 61 +/- 6%, p less than 0.001) and exercise (66 +/- 4% versus 74 +/- 6%, p less than 0.001) than in 42 age-matched normal subjects. Rest thallium-201 images from 9 patients showed abnormal RV uptake in 8 and normal LV uptake in 8. Thus, in adult patients with SCA, LV function was normal during exercise in all patients and at rest in all but 1 patient. The LVEF, however, was lower than that in age-matched normal subjects. RV function was abnormal in most patients at rest and during exercise. RV thallium-201 uptake suggested pressure or volume overload (or both), most likely due to pulmonary vaso-occlusive complications of the disease

  1. EANM/ESC guidelines for radionuclide imaging of cardiac function

    DEFF Research Database (Denmark)

    Hesse, B.; Lindhardt, T.B.; Acampa, W.

    2008-01-01

    radionuclide ventriculography, gated myocardial perfusion scintigraphy, gated PET, and studies with non-imaging devices for the evaluation of cardiac function. The items covered are presented in 11 sections: clinical indications, radiopharmaceuticals and dosimetry, study acquisition, RV EF, LV EF, LV volumes...

  2. Exercise thallium testing in ventricular preexcitation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-05-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation.

  3. Exercise thallium testing in ventricular preexcitation

    International Nuclear Information System (INIS)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-01-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation

  4. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  5. Evaluation of ventriculography as a supplement to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nakstad, P.; Sortland, O.; Hovind, K.

    1982-04-01

    The diagnostic value of ventriculography (VGR) as a supplement to computed tomography (CT) is evaluated in 42 patients. CT was slightly superior for diagnosing expanding lesions and could tell more about the size and nature of the processes in this selected material which includes only lesions adjacent to the ventricular system. VGR yielded more information about the attachment of a tumor to the wall, floor, or roof of the ventricles. Stenosis or occlusion of the Sylvian aqueduct, communicating hydrocephalus, and basal adhesive arachnoiditis were diagnosed by VGR, while the correct diagnosis could be suggested only by CT in these cases.

  6. Influence of age on left ventricular performance during exercise in normal Japanese subject

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Koyama, Takao; Aoki, Toshikazu; Makino, Katsutoshi; Yamamuro, Masashi; Nakai, Kyudayu; Nakamura, Masayuki; Nakano, Takeshi.

    1990-01-01

    To assess the effects of age on left ventricular performance, multistage supine ergometer exercise radionuclide ventriculography (RNV) was performed in 92 normal subjects. The subjects ranged in age from 24 to 86 years and were free of cardiopulmonary disease and diabetes. Age-related changes in exercise duration, left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), cardiac output (CO) left ventricular ejection fraction (LVEF), left ventricular dv/dt, systolic and diastolic time indexes of dv/dt, and peak systolic pressure/left ventricular end-systolic volume (PSP/LVESV) were analyzed at rest and during the peak exercise stage. Age-related decrease in LVEDV and peak diastolic dv/dt were significant at rest. The time indexes of ECG R to peak systolic dv/dt and time of end-systole to peak diastolic dv/dt also were prolonged with age. Both maximum heart rate and exercise duration were shown to decline with age. No age-related difference was observed in LVESV, LVEF or PSP/LVESV either at rest or during exercise. However, the change of LVEF and LVESV during exercise was less in subjects aged 60 or more. These results indicate decreased left ventricular function during exercise in elderly subjects. (author)

  7. Radionuclide diagnostics of right ventricle

    International Nuclear Information System (INIS)

    Zaorska-Rajca, J.

    1993-01-01

    Difficulties in evaluating the right ventricle function motivate to making research into new non-invasive methods. Four radionuclide methods that are used to access the right ventricle have been discussed in this paper: first-pass angiocardiography, gated equilibrium ventriculography with red blood cells labelled in vivo technetium- 99 Tc, ventriculography with radioactive xenon 133 and a computerized single probe. Advantages and disadvantages of using each method have been discussed. RNV 99m Tc method has been recognized as the best one to evaluate RV function. Results of the right ventricle assessment in patients have been discussed in the following clinical groups: chronic cor pulmonale (CP), chronic lung disease without pulmonary arterial hypertension (LD), coronary artery disease (CAD), in patients after infarction (IMA and IMi), dilated cardiomyopathy (KZ) and valvular heart diseases (Wm and Wa). Abnormals in right ventricle function occur with different intensity in all groups, although they no specificity. The highest abnormality occurs in patients with KZ, CP, IMi and Wm, the lowest one - in patients with CAD. Abnormalities are higher in patients with congestive heart failure. In most pathological groups the right ventricle dysfunction is connected with the left ventricle insufficiency. The interdependence between the dysfunction of both ventricles is differs in particular diseases. Assessment of right ventricle function with radionuclide methods plays an important role in diagnosis and control therapy of cardiopulmonary diseases. (author). 385 refs, 48 figs, 6 tabs

  8. Effect of exercise on erythrocyte count and blood activity concentration after technetium-99m in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstom, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    The effects of exercise on blood radiotracer concentration after technetium-99m in vivo red blood cell labeling was studied. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased in erythrocyte count (r=0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. It was concluded that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  9. Hemodynamic and radionuclide effects of acute captopril therapy for heart failure: changes in left and right ventricular volumes and function at rest and during exercise

    International Nuclear Information System (INIS)

    Massie, B.; Kramer, B.L.; Topic, N.; Henderson, S.G.

    1982-01-01

    Although the resting hemodynamic effects of captopril in congestive heart failure are known, little information is available about the hemodynamic response to captopril during exercise or about changes in noninvasive measurements of the size and function of both ventricles. In this study, 14 stable New York Heart Association class III patients were given 25 mg of oral captopril. Rest and exercise hemodynamic measurements and blood pool scintigrams were performed simultaneously before and 90 minutes after captopril. The radionuclide studies were analyzed for left and right ventricular end-diastolic volumes, end-systolic volumes, ejection fractions and pulmonary blood volume. The primary beneficial responses at rest were decreases in left and right ventricular end-diastolic volumes from 388 +/- 81 to 350 +/- 77 ml and from 52 +/- 26 to 43 +/- 20 volume units, respectively, and in their corresponding filling pressures, from 24 +/- 10 to 17 +/- 9 mm Hg and 10 +/- 5 to 6 +/- 5 mm Hg. Although stroke volume did not increase significantly, both left and right ventricular ejection fractions increased slightly, from 19 +/- 6% to 22+/- 5% and from 25 +/- 9% to 29 +/- 11%, respectively. During exercise, similar changes were noted in both hemodynamic and radionuclide indexes. This, in patients with moderate symptomatic limitation from chronic heart failure, captopril predominantly reduces ventricular volume and filling pressure, with a less significant effect on cardiac output. These effects persist during exercise, when systemic vascular resistance is already very low. Radionuclide techniques are valuable in assessing the drug effect in these subjects, particularly when ventricular volumes are also measured

  10. Effect of exercise on erythrocyte count and blood activity concentration after /sup 99m/Tc in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstam, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    We studied the effect of exercise on blood radiotracer concentration after /sup 99m/Tc in vivo red blood cell labeling. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased during exercise in all 13 subjects. Percent increase in activity correlated with percent increase in erythrocyte count (r . -0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. We conclude that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  11. Exercise tolerance in mitral stenosis and chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Uenami, Atsushi; Mizuno, Toshikazu; Chiba, Hiroshi; Ohno, Masanori; Wakino, Kouichi; Sawada, Yoshihiro; Ohno, Joichi; Kume, Kiyoshi.

    1986-01-01

    Serial radionuclide ventriculography was performed using a newly developed ''real-time'' system, and left ventricular ejection fraction (LVEF), right ventricular ejection fraction (RVEF), stroke volume (SV), and cardiac output (CO) were measured during graded supine exercise in five patients with mitral stenosis (MS), in five patients with chronic obstructive pulmonary disease (COPD) and in five healthy subjects. Simultaneous pulmonary gas exchange analysis permitted determining the anaerobic threshold, which is the point during incremental exercise when lactate begins to accumulate in the blood. LVEF at the anaerobic threshold was not significantly changed in any patient groups and in healthy subjects, but RVEF at the anaerobic threshold was lower in COPD and MS patients as compared with healthy subjects. In MS, SV during exercise was reduced at the anaerobic threshold, but not in COPD or in healthy subjects. In conclusion, reduced working capacity is related to decreased RVEF in both COPD and MS, but the inhibited increase in CO during exercise is also important for the working capacity in MS. (author)

  12. Studies on clinical significance of exercise-induced ST-segment depression at non-infarct-related leads in the patients with prior myocardial infarction using the stress scintigraphy

    International Nuclear Information System (INIS)

    Ohkubo, Toshitaka

    1988-01-01

    Stress Tl-201 myocardial imaging and stress radionuclide ventriculography were performed in a total of 67 patients with prior myocardial infarction (MI) to assess the clinical significance of exercise induced ST-segment depression at non-infarct-related leads on ECG during the chronic stage. The patients consisted of 12 with inferior MI with single vessel disease (SVD) that showed no precordial ST-segment depression; 7 with inferior MI with SVD accompanied by precordial ST-segment depression; 13 with inferior MI with multivessel disease (MVD); 20 with anterior MI with SVD that showed no inferior ST-segment depression; 4 with anterior MI with SVD accompanied by inferior ST-segment depression; and 11 with anterior MI with MVD. In cases of SVD, the incidence of ST-segment depression at non-infarct-related leads was higher for inferior MI (36.8%) than anterior MI (16.7%). Myocardial imaging revealed large infarct and infarct extending into the inferoseptal wall of the left ventricle (LV) in cases of exercise induced precordial ST-segment depression; and infarct extending into the lateral wall of LV in cases of exercise induced inferior ST-segment depression. In detecting MVD, stress Tl-201 myocardial imaging was superior to exercise electrocardiography and stress radionuclide ventriculography, but this was not statistically significant. Prognostic value of error rate for detecting MVD was significantly improved with a discriminant analysis. Exercise induced ST-segment depression on ECG should be of clinical significance in reflecting myocardial ischemia around an infarcted area. (Namekawa, K)

  13. Myocardial 201Tl washout after combined dipyridamole submaximal exercise stress: Reference values from different patient groups

    International Nuclear Information System (INIS)

    Fridrich, L.

    1989-01-01

    Dipyridamole stress is favorable in patients unable to exercise maximally for 201 Tl myocardial scintigraphy. Aside from an analysis of uptake defects, proper washout analysis can be limited by heart rate variations when isolated dipyridamole stress is used. Heart rate standardized 201 Tl washout kinetics after a combined dipyridamole and submaximal exercise stress protocol (CDSE), feasible in elderly patients as well as in patients with peripheral artery disease, were therefore studied to investigate the 201 Tl washout after CDSE in differently defined patient groups: Group I comprised 19 patients with documented heart disease and angiographically excluded coronary artery disease (CAD); group II contained 17 patients with a very low likelihood of CAD determined by both normal exercise radionuclide ventriculography and normal 201 Tl uptake. Group III comprised 56 patients with a 50% pretest likelihood of CAD but normal 201 Tl uptake. Mean washout values were nearly identical in all groups. Despite similar uptake patterns, however, washout standardized by CDSE was significantly lower than the normal washout values after maximal treadmill exercise. Thus an obviously lower 201 Tl washout after CDSE than after maximal treadmill exercise must be considered if washout analysis criteria after dipyridamole are applied to evaluate ischemic heart disease. Nevertheless, heart rate elevation achieved by additional submaximal exercise stress seems necessary, adequate and clinically safe for standardisation of washout analysis in dipyridamole 201 Tl scintigraphy. (orig.)

  14. Being prepared to verify the CTBT-Atmospheric Transport modeling and radionuclide analysis at the Austrian National Data Centre during the NDC Preparedness Exercise 2009

    Science.gov (United States)

    Wotawa, Gerhard; Schraick, Irene

    2010-05-01

    An explosion in the Kara-Zhyra mine in Eastern Kazakhstan on 28 November 2009 around 07:20 UTC was recorded by both the CTBTO seismic and infrasound networks. This event triggered a world-wide preparedness exercise among the CTBTO National Data Centres. Within an hour after the event was selected by the German NDC, a computer program developed by NDC Austria based on weather forecasts from the European Centre for Medium-Range Weather Forecasts (ECMWF) and from the U.S. National Centers for Environmental Prediction (NCEP) was started to analyse what Radionuclide Stations of the CTBTO International Monitoring System (IMS) would be potentially affected by the release from a nuclear explosion at this place in the course of the following 3-10 days. These calculations were daily updated to consider the observed state of the atmosphere instead of the predicted one. Based on these calculations, automated and reviewed radionuclide reports from the potentially affected stations as produced by the CTBTO International Data Centre (IDC) were looked at. An additional analysis of interesting spectra was provided by the Seibersdorf Laboratories. Based on all the results coming in, no evidence whatsoever was found that the explosion in Kazakhstan was nuclear. This is in accordance with ground truth information saying that the event was caused by the detonation of more than 53 Tons of explosives as part of mining operations. A number of conclusions can be drawn from this exercise. First, the international, bilateral as well as national mechanisms and procedures in place for such an event worked smoothly. Second, the products and services from the CTBTO IDC proved to be very useful to assist the member states in their verification efforts. Last but not least, issues with the availability of data from IMS radionuclide stations do remain.

  15. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart diseases (preliminary report)

    International Nuclear Information System (INIS)

    Madeja, G.; Konieczna, S.; Gosiewska-Marcinkowska, E.; Leszek, P.

    1991-01-01

    In 15 patients with mitral valve defect and 10 patients with aortic valve defect, left ventricular end-diastolic and end-systolic volumes were determined by gated radionuclide angiography. The results were compared with contrast ventriculography. The correlation coefficient between the two methods was much lower in cases of mitral valve diseases. (author). 1 tab

  16. Clinical significance of exercise-induced left ventricular wall motion abnormality occurring at a low heart rate

    International Nuclear Information System (INIS)

    Kimchi, A.; Rozanski, A.; Fletcher, C.; Maddahi, J.; Swan, H.J.; Berman, D.S.

    1987-01-01

    We studied the relationship between the heart rate at the time of onset of exercise-induced wall motion abnormality and the severity of coronary artery disease in 89 patients who underwent exercise equilibrium radionuclide ventriculography as part of their evaluation for coronary artery disease. Segmental wall motion was scored with a five-point system (3 = normal; -1 = dyskinesis); a decrease of one score defined the onset of wall motion abnormality. The onset of wall motion abnormality at less than or equal to 70% of maximal predicted heart rate had 100% predictive accuracy for coronary artery disease and higher sensitivity than the onset of ischemic ST segment depression at similar heart rate during exercise: 36% (25 of 69 patients with coronary disease) vs 19% (13 of 69 patients), p = 0.01. Wall motion abnormality occurring at less than or equal to 70% of maximal predicted heart rate was present in 49% of patients (23 of 47) with critical stenosis (greater than or equal to 90% luminal diameter narrowing), and in only 5% of patients (2 of 42) without such severe stenosis, p less than 0.001. The sensitivity of exercise-induced wall motion abnormality occurring at a low heart rate for the presence of severe coronary artery disease was similar to that of a deterioration in wall motion by more than two scores during exercise (49% vs 53%) or an absolute decrease of greater than or equal to 5% in exercise left ventricular ejection fraction (49% vs 45%)

  17. Added prognostic value of ischaemic threshold in radionuclide myocardial perfusion imaging: a common-sense integration of exercise tolerance and ischaemia severity

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Cecilia [IRCCS AOU San Martino-National Institute for Cancer Research, CNR Institute of Bioimaging and Molecular Physiology, Section of Genoa c/o Nuclear Medicine, Pad. Sommariva, Genoa (Italy); Acampa, Wanda [National Council of Research, Naples (Italy); Bauckneht, Matteo; Capitanio, Selene; Fiz, Francesco; Dib, Bassam; Sambuceti, Gianmario [University of Genoa, IRCCS-AOU San Martino-National Institute for Cancer Research, Nuclear Medicine, Department of Health Science, Genoa (Italy); Daniele, Stefania; Cantoni, Valeria; Zampella, Emilia; Assante, Roberta; Cuocolo, Alberto [University Federico II, Nuclear Medicine, Naples (Italy); Bruzzi, Paolo [IRCCS AOU San Martino-National Institute for Cancer Research, Epidemiology Unit, Genoa (Italy)

    2015-04-01

    Reversible ischaemia at radionuclide myocardial perfusion imaging (MPI) accurately predicts risk of cardiac death and nonfatal myocardial infarction (major adverse cardiac events, MACE). This prognostic penetrance might be empowered by accounting for exercise tolerance as an indirect index of ischaemia severity. The present study aimed to verify this hypothesis integrating imaging assessment of ischaemia severity with exercise maximal rate pressure product (RPP) in a large cohort of patients with suspected or known coronary artery disease (CAD). We analysed 1,502 consecutive patients (1,014 men aged 59 ± 10 years) submitted to exercise stress/rest MPI. To account for exercise tolerance, the summed difference score (SDS) was divided by RPP at tracer injection providing a clinical prognostic index (CPI). Reversible ischaemia was documented in 357 patients (24 %) and was classified by SDS as mild (SDS 2-4) in 180, moderate (SDS 5-7) in 118 and severe (SDS >7) in 59. CPI values of ischaemic patients were clustered into tertiles with lowest and highest values indicating low and high risk, respectively. CPI modified SDS risk prediction in 119/357 (33 %) patients. During a 60-month follow-up, MACE occurred in 68 patients. Kaplan-Meier analysis revealed that CPI significantly improved predictive power for MACE incidence with respect to SDS alone. Multivariate Cox analysis confirmed the additive independent value of CPI-derived information. Integration of ischaemic threshold and ischaemia extension and severity can improve accuracy of exercise MPI in predicting long-term outcome in a large cohort of patients with suspected or known CAD. (orig.)

  18. Comparison between radioisotopic ventriculography in balance with Tc99-albumine-DTPA and quantitative gated SPECT with Tc-99m-MIBI for determining the eject fraction of left ventricle

    International Nuclear Information System (INIS)

    Noguera, E. C; Jaime, Adelina; Pamellin, Miriam; Veliz, J

    2002-01-01

    Radionuclide ventriculography (RNV) and electrocardiography gated myocardial perfusion single photon emission computed tomography (GSPECT), can be used to assess the ventricular function.The purpose of this study was:1) to compare left ventricular ejection fraction (LVEF(%) using post-stress or rest gated GSPECT with LVEF by resting RNV and 2) to evaluate the 99m-Tc99m human serum albumin (HAS) with diethylenetriaminepenta-acetic acid (DTPA) (99m-TcHSA-DTPA) as a potential use a as blood pool imaging agent (Au)

  19. Detection of exercise induced ischemia in the asymptomatic recent post myocardial infarction patient: comparison of stress electrocardiography and radionuclide angiography

    International Nuclear Information System (INIS)

    Jengo, J.A.; Brizendine, M.; Dykstra, L.; Sweet, J.; Bruno, M.; Garcia, A.

    1982-01-01

    The purpose of this study was to compare the techniques of low level stress electrocardiography and radionuclide angiographic wall motion analysis for the detection of new areas of myocardial ischemia in the asymptomatic recent post-myocardial infarction patient. The protocol consisted of obtaining a resting, RAO upright first pass radionuclide angiocardiogram using 15 mCi of 99m technetium-DTPA. The study suggests that assessment of segmental wall motion during low level stress can detect areas of myocardium at high risk either intermixed with or in addition to recently infarcted areas in the asymptomatic post-infarction patient, which are not detected by ECG. This high risk subset of patients can then be observed or treated in a more vigorous manner. This technique allows for not only the identification of additional areas of myocardium at jeopardy but also provides information regarding the severity of ischemic dysfunction, an important prognostic and therapeutic factor

  20. Visualisation of regional motility disorders in the left ventricular wall using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Kaiser, H.

    1985-01-01

    During this study ECG-triggered intramyocardial scintiscans were obtained following in-vivo labelling of erythrocytes (99mTc) from 74 patients showing coronary heart disease and analysed with the aim to assess the suitability of this method for the detection of mural motility disorders and for visualisation of the accurate size of the left ventricle. The results of the intramyocardial scintiscans were evaluated against those of levocardiograms recorded for reasons of comparison and found to demonstrate mural motility disorders with a specifity of 0.70 and a sensitivity of 0.75. Relatively reliable data to diagnose those myocardial motility disorders were obtained by combined analysis of the individual scintiphotographic displays of amplitudes, phases, ejection fractions and positive gradients. The investigation of further parameters like the recorded stroke volumes and negative gradients provided no additional information. The phase recording proved to be the most suitable parameter to assess the size of the left ventricle. All other recordings gave a distorted picture of the left ventricle in terms of a reduction in size. (TRV) [de

  1. An attempt to evaluate pulmonary hypertension by phase analysis of radionuclide ventriculography

    International Nuclear Information System (INIS)

    Masuoka, Takeshi; Toyama, Hinako; Ajisaka, Ryuuichi

    1988-01-01

    Using phase analysis derived from the gated blood pool imaging, the pattern of right ventricular regional contraction was examined in 5 patients with pulmonary hypertension who showed 30 mmHg of pulmonary arterial systolic pressure and 20 mmHg or more of mean pulmonary arterial pressure. All of the patients had markedly delayed phase in contraction of right ventricular outflow tract. Pulmonary arterial pressure positively correlated with both the proportion of delayed phase area to the whole right ventricle and mean phase difference between the right and left ventricles. The results suggest the usefulness of phase analysis in the non-invasive evaluation of incease in overloading of right ventricular pressure. (Namekawa, K)

  2. Potential and limitations of radionuclide-based exercise testing before and after operation in the patient with coronary artery disease

    International Nuclear Information System (INIS)

    Borer, J.S.; Phillips, P.; Jacobstein, J.

    1982-01-01

    The authors assess the potential benefits and limitations of radionuclide cineangiography when used to select patients with ischemic heart disease for operation, to precisely plan the operation, and to assess the effects of such therapy. The results indicate that this technique provides potentially important benefits, but also several limitations. Additional studies are required to clarify the optimal role for this technique in the evaluation of the patient with coronary artery disease. (Auth.)

  3. Radionuclide analysis of right and left ventricular response to exercise in patients with atrial and ventricular septal defects

    International Nuclear Information System (INIS)

    Peter, C.A.; Bowyer, K.; Jones, R.H.

    1983-01-01

    In patients with ventricular or atrial septal defect, the ventricle which is chronically volume overloaded might not appropriately respond to increased demand for an augmentation in output and thereby might limit total cardiac function. In this study we simultaneously measured right and left ventricular response to exercise in 10 normal individuals, 10 patients with ventricular septal defect (VSD), and 10 patients with atrial septal defect (ASD). The normal subjects increased both right and left ventricular ejection fraction, end-diastolic volume, and stroke volume to achieve a higher cardiac output during exercise. Patients with VSD failed to increase right ventricular ejection fraction, but increased right ventricular end-diastolic volume and stroke volume. Left ventricular end-diastolic volume did not increase in these patients but ejection fraction, stroke volume, and forward left ventricular output achieved during exercise were comparable to the response observed in healthy subjects. In the patients with ASD, no rest-to-exercise change occurred in either right ventricular ejection fraction, end-diastolic volume, or stroke volume. In addition, left ventricular end-diastolic volume failed to increase, and despite an increase in ejection fraction, left ventricular stroke volume remained unchanged from rest to exercise. Therefore, cardiac output was augmented only by the heart rate increase in these patients. Right ventricular function appeared to be the major determinant of total cardiac output during exercise in patients with cardiac septal defects and left-to-right shunt

  4. Echocardiography, ventriculography and coronary angiography in patients just recovering from acute myocardial infarction

    International Nuclear Information System (INIS)

    Goetz, S.

    1983-01-01

    Comparative evaluations were carried out on the basis of ventriculography, echocardiography and corornary angiography that would permit to throw some light on the following issues: Can the changes in overall ventricular function occurring in response to the processes in the infarcted zone be visualised by means of M-mode scans. Which degree of accuracy can be achieved, if attempts are made to establish an echocardiographic diagnosis on the basis of M-mode scans in order to confirm regional contractility disorders revealed by ventriculography. (orig./MG) [de

  5. Symptom-limited exercise testing causes sustained diastolic dysfunction in patients with coronary disease and low effort tolerance.

    Science.gov (United States)

    Fragasso, G; Benti, R; Sciammarella, M; Rossetti, E; Savi, A; Gerundini, P; Chierchia, S L

    1991-05-01

    Exercise stress testing is routinely used for the noninvasive assessment of coronary artery disease and is considered a safe procedure. However, the provocation of severe ischemia might potentially cause delayed recovery of myocardial function. To investigate the possibility that maximal exercise testing could induce prolonged impairment of left ventricular function, 15 patients with angiographically proved coronary disease and 9 age-matched control subjects with atypical chest pain and normal coronary arteries were studied. Radionuclide ventriculography was performed at rest, at peak exercise, during recovery and 2 and 7 days after exercise. Ejection fraction, peak filling and peak emptying rates and left ventricular wall motion were analyzed. All control subjects had a normal exercise test at maximal work loads and improved left ventricular function on exercise. Patients developed 1 mm ST depression at 217 +/- 161 s at a work load of 70 +/- 30 W and a rate-pressure product of 18,530 +/- 4,465 mm Hg x beats/min. Although exercise was discontinued when angina or equivalent symptoms occurred, in all patients diagnostic ST depression (greater than or equal to 1 mm) developed much earlier than symptoms. Predictably, at peak exercise patients showed a decrease in ejection fraction and peak emptying and filling rates. Ejection fraction and peak emptying rate normalized within the recovery period, whereas peak filling rate remained depressed throughout recovery (p less than 0.002) and was still reduced 2 days after exercise (p less than 0.02). In conclusion, in patients with severe impairement of coronary flow reserve, maximal exercise may cause sustained impairement of diastolic function.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Myocardial function and perfusion in the CREST syndrome variant of progressive systemic sclerosis. Exercise radionuclide evaluation and comparison with diffuse scleroderma

    International Nuclear Information System (INIS)

    Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.; Owens, G.R.; Steen, V.D.; Rodnan, G.P.

    1984-01-01

    Myocardial function and perfusion were evaluated in 22 patients with progressive systemic sclerosis with the CREST syndrome using exercise and radionuclide techniques, pulmonary function testing, and chest roentgenography. The results were compared with a similar study of 26 patients with progressive systemic sclerosis with diffuse scleroderma. The prevalence of thallium perfusion abnormalities was similar in the groups with CREST syndrome and diffuse scleroderma, (64 percent versus 77 percent), but the defects were significantly smaller in the CREST syndrome (p less than 0.01). Reperfusion thallium defects in the absence of extramural coronary artery disease were seen in 38 percent of patients with diffuse scleroderma. This finding was not seen in any of the patients with the CREST syndrome. In diffuse scleroderma, abnormalities of both right and left ventricular function were related to larger thallium perfusion defects. In the CREST syndrome, abnormalities of left ventricular function were minor, were seen only during exercise, and were unrelated to thallium perfusion defects. Abnormal resting right ventricular function was seen in 36 percent of the patients with the CREST syndrome and was associated with an isolated decrease in diffusing capacity of carbon monoxide. It is concluded that the cardiac manifestations of the CREST syndrome are distinct from those found in diffuse scleroderma. Unlike diffuse scleroderma, abnormalities of left ventricular function in the CREST syndrome are minor and are unrelated to abnormalities of coronary perfusion. Right ventricular dysfunction in the CREST syndrome appears to be primarily related to pulmonary vascular disease

  7. Left ventricular end-diastolic volume is decreased at maximal exercise in athletes with marked repolarisation abnormalities: a continuous radionuclide monitoring study

    International Nuclear Information System (INIS)

    Flotats, Albert; Camacho, Valle; Mena, Esther; Estorch, Montserrat; Tembl, Ana; Fuertes, Jordi; Carrio, Ignasi; Serra-Grima, Ricard; Borras, Xavier; Cinca, Juan

    2005-01-01

    Although marked repolarisation abnormalities (MRAs) are considered innocuous in trained athletes, their functional significance awaits clarification. The aim of this study was to further evaluate the pathophysiological implications of such MRAs. We compared left ventricular (LV) functional response to exhausting exercise in 39 male athletes with (n=22) or without (n=17) MRAs and with no structural cardiac abnormalities, by means of a portable radionuclide monitoring system (Vest, Capintec, Inc., Ramsey, NJ). MRAs were defined by the presence of negative T waves ≥2 mm in three or more rest ECG leads. The Vest data were averaged for 30 s and analysed at baseline and at different heart rate (HR) values (50%, 75%, 85%, 95% and 100% of peak HR), as well as at 2, 5 and 10 min of recovery. There were no significant differences in the effect of exhausting exercise between athletes with and athletes without MRAs. However, there was a significant difference in the trend in end-diastolic volume (EDV) during exercise depending upon the group of athletes considered (p=0.05). EDV differed significantly between the two groups of athletes at peak HR (p=0.031). EDV in athletes with MRAs was lower than that in athletes without MRAs (102%±7% vs 107%±8%, p=0.034). EDV is decreased at peak HR in athletes with MRAs. Such high HR values are infrequently achieved or maintained during sporting activities; therefore, in the absence of structural heart disease, MRAs should not preclude physical training and competitive availability. (orig.)

  8. The cardiomyopathy in Friedreich's ataxia: isotopic ventriculography and myocardial imaging with thallium-201

    International Nuclear Information System (INIS)

    Therriault, L.; Lamoureux, G.; Cote, M.; Plourde, G.; Lemieux, B.

    1984-01-01

    Myocardial scanning after the intravenous administration of Thallium 201 was used to evaluate regional myocardial perfusion in 14 patients with Friedreich's ataxia. Isotopic ventriculography was also used to assess left ventricular contractility. Myocardial images in patients with Friedreich's ataxia were found to be precociously abnormal irrespective of the degree of neurological impairment or of the severity of myocardial hypertrophy

  9. Usefulness of acoustic quantification method in left ventricular volume and ejection fraction. Compared with ventriculography and scintigraphy

    International Nuclear Information System (INIS)

    Shibata, Takahiro; Honda, Youichi; Kashiwagi, Hidehiko

    1996-01-01

    Acoustic quantification method (AQ: on-line automated boundary detection system) has proved to have a good correlation with left ventriculography (LVG) and scintigraphy (SG) in patients with normal left ventricular (LV) function. The aim of this study is to determine whether AQ is also useful in patients with abnormal LV function. We examined 54 patients with LV asynergy. End-diastolic volumes with AQ, LVG and SG were 77, 135, 118 ml. A good correlation was found between AQ and LVG and SG (LVG; r=0.81, SG; r=0.68). End-systolic volumes with AQ, LVG and SG were 38, 64 and 57 ml. Left ventricular volumes obtained from AQ had a good correlation with LVG and SG, but were underestimated. LV ejection fraction obtained from AQ had good correlation with those with LVG and SG (LVG; r=0.84. SG; r=0.77). On-line AQ appears to be a useful noninvasive method for evaluation of the left ventricular ejection fraction, but care must be exercised when estimations of left ventricular volumes are made. (author)

  10. Assessment of right ventricular function with nonimaging first pass ventriculography and comparison of results with gamma camera studies.

    Science.gov (United States)

    Zhang, Z; Liu, X J; Liu, Y Z; Lu, P; Crawley, J C; Lahiri, A

    1990-08-01

    A new technique has been developed for measuring right ventricular function by nonimaging first pass ventriculography. The right ventricular ejection fraction (RVEF) obtained by non-imaging first pass ventriculography was compared with that obtained by gamma camera first pass and equilibrium ventriculography. The data has demonstrated that the correlation of RVEFs obtained by the nonimaging nuclear cardiac probe and by gamma camera first pass ventriculography in 15 subjects was comparable (r = 0.93). There was also a good correlation between RVEFs obtained by the nonimaging nuclear probe and by equilibrium gated blood pool studies in 33 subjects (r = 0.89). RVEF was significantly reduced in 15 patients with right ventricular and/or inferior myocardial infarction compared to normal subjects (28 +/- 9% v. 45 +/- 9%). The data suggests that nonimaging probes may be used for assessing right ventricular function accurately.

  11. Exercise

    Science.gov (United States)

    ... decreased bone density with an increased risk of fracture, and shallow, inefficient breathing. An exercise program needs ... and-Soul (Feb. 2013 issue) (.pdf) Download Document Rehabilitation: Recommendations for Persons with MS (.pdf) Download Brochure ...

  12. Clinical evaluation of right ventricular function using radionuclide method

    International Nuclear Information System (INIS)

    Ishii, Yasushi; Tamaki, Nagayoshi; Mukai, Takao; Motohara, Seiichito; Ikekubo, Katsuji.

    1982-01-01

    Essential thing to evaluate the right ventricular (RV) function is its volumetric measurement. However, its geometrical complexity has hampered this even with the contrast ventriculography, unlike left ventricle (LV). Meanwhile, the radionuclide time-activity curve from the first pass of a tracer through RV in the RAO view provides the most reliable data of the RV ejection fraction (RVEF), same data from the multigated equilibrium study in the LAO view is necessitated for a repeated intervention study, but the latter imposes a critical problem to locate ROI separately in the LAO view. Finally, three dimensional location of RV should be mandatory using new method as the dynamic SPECT in the future. (author)

  13. Ventriculography and cisternography with water-soluble contrast media in infants with myelomeningocele

    International Nuclear Information System (INIS)

    Yamada, H.; Nakamura, S.; Tanaka, Y.; Tajima, M.; Kageyama, N.

    1982-01-01

    Fifty-four newborn infants with myelomeningocele and hydrocephalus were studied by ventriculography using water-soluble contrast media; 20 were also studied by metrizamide myeloencephalography and computerized tomographic (CT) cisternography. Ventriculography suggested that the aqueduct was patent in all cases. Outflow of contrast medium from the fourth ventricle was slow in most cases, complete obstruction was seen in 15%, communication was delayed at the outlet in 54%, and rather free communication was observedin 31%. Metrizamide myeloencephalography and CT cisternography suggested a partial block at the level of the ambient cisterns in approximately one-third of infants. These findings support the concept that flow of cerebrospinal fluid is reduced in several areas. Aqueductal stenosis was not considered an important factor in hydrocephalus, while the most important site of obstruction was felt to be the lowest portion of the fourth ventricle

  14. Right-sided phase abnormalities on gated blood pool ventriculography: Demonstration of six different patterns

    International Nuclear Information System (INIS)

    Bahar, R.H.; Abdel-Dayem, H.M.; Ziada, G.; Al-Suhali, A.; Constantinides, C.; Nair, K.M.

    1986-01-01

    Phase pattern abnormalities on multiple gated blood pool ventriculography are better reported for the left ventricle (LV) than for the right side of the heart. In a study of 92 patients who also underwent contrast ventriculography, the authors identified six different patterns of right-sided phase abnormalities and their causes: right bundle-branch block, causing delayed phase in the entire right ventricle (RV); ischemic right coronary artery disease, causing delayed phase in the inferior RV wall; pericardial effusion, causing an L-shaped area of delayed phase to the right of the septum and below the LV; pulmonary hypertension, causing delayed phase in the pulmonary infundibulum; tricuspid regurgitation, causing a crescentic area of delayed phase around and below the right RV and extending below the LV as well, and atrial septal defect causing an abnormally large auricular phase

  15. Radionuclide trap

    International Nuclear Information System (INIS)

    McGuire, J.C.

    1978-01-01

    The deposition of radionuclides manganese-54, cobalt-58 and cobalt-60 from liquid sodium coolant is controlled by providing surfaces of nickel or high nickel alloys to extract the radionuclides from the liquid sodium, and by providing surfaces of tungsten, molybdenum or tantalum to prevent or retard radionuclide deposition

  16. Right ventriculography as a valid method for the diagnosis of tricuspid insufficiency.

    Science.gov (United States)

    Ubago, J L; Figueroa, A; Colman, T; Ochoteco, A; Rodríguez, M; Durán, C M

    1981-01-01

    The value of right ventriculography in the diagnosis of tricuspid insufficiency (TI) is often questioned because of 1) the high incidence of premature ventricular contractions (PVCs) during injections and 2) interference of the catheter in the valve closure mechanism. In 168 patients a commercially available, not preshaped, balloon-tipped catheter was used for right ventriculography. To avoid the induction of PVCs, the catheter tip was placed in the middle third of the diafragmatic wall of the right ventricle, and the balloon was inflated, becoming trapped by the trabeculae. In this position the catheter's side holes should be located in the inflow chamber. To ensure this correct position, and therefore lack of ectopic beats during angiography, a saline test injection was performed previously in every case. With this technique the incidence of PVCs during ventriculography was only 7.7%. In all but one case, such beats were isolated. The 168 patients were divided into three groups according to their likelihood of experiencing tricuspid interference by the catheter: group 1 included 41 patients with a normal heart or with coronary artery disease. No one from this group had TI. Of group II, 28 patients with right ventricular pressure or volume overload or cardiomyopathy, only 2 had TI, both with a previous clinical diagnosis of regurgitation. Group III contained 99 patients with rheumatic heart disease. Thirty-five of them showed angiographic TI, and 24 of these had this diagnosis confirmed either clinically or at surgery. It is felt that this technique of right ventriculography, with its low incidence of PVCs and slight interference with tricuspid closure, is a valid method for the objective study of the tricuspid valve.

  17. Magnetic resonance ventriculography with gadolinium DTPA: report of two cases

    International Nuclear Information System (INIS)

    Siebner, H.R.; Einsiedel, H. von; Conrad, B.

    1997-01-01

    We report intrathecal use of gadolinium DTPA for MRI of the cerebrospinal fluid (CSF). In two patients with leptomeningeal carcinomatosis, we injected 0.01 mmol gadolinium DTPA into the lateral ventricle via an Ommaya device. Coronal T1-weighted images of the head were obtained at 0.2 T prior to and after injection. There was pronounced enhancement of CSF close to the injection site, allowing good delineation of CSF and surrounding brain tissue. No side effects occurred. MRI with intrathecal administration of highly diluted gadolinium DTPA may be a promising alternative to conventional investigation of CSF-filled cavities using iodinated X-ray contrast media or radionuclides. (orig.). With 3 figs

  18. Exercise

    DEFF Research Database (Denmark)

    Idorn, Manja; thor Straten, Eivind Per

    2016-01-01

    We recently demonstrated that voluntary exercise leads to an influx of immune cells in tumors and a greater than 60% reduction in tumor incidence and growth across several mouse models. Improved immunological control of tumor progression may have important clinical implications in the prevention...

  19. Evaluation of the effect of different types and location of pacemaker on cardiac function using radionuclide techniques

    International Nuclear Information System (INIS)

    Shi Rongfang; Liu Xiujie; Guo Xiuzhen

    1993-01-01

    Left ventricular function was measured in 24 patients using radionuclide ventriculography before and after planting different types of pacemakers. The results showed that the heart rate, peak filling rate (PFR) and relative cardiac output (RCO) were significantly increased after planting the pacemaker. However, the effects of AAI and VVI on the synchronism of LV were different. AAI can significantly improve the synchronism and compliance of LV

  20. Radionuclide toxicity

    International Nuclear Information System (INIS)

    Galle, P.

    1982-01-01

    The aim of this symposium was to review the radionuclide toxicity problems. Five topics were discussed: (1) natural and artificial radionuclides (origin, presence or emission in the environment, human irradiation); (2) environmental behaviour of radionuclides and transfer to man; (3) metabolism and toxicity of radionuclides (radioiodine, strontium, rare gas released from nuclear power plants, ruthenium-activation metals, rare earths, tritium, carbon 14, plutonium, americium, curium and einsteinium, neptunium, californium, uranium) cancerogenous effects of radon 222 and of its danghter products; (4) comparison of the hazards of various types of energy; (5) human epidemiology of radionuclide toxicity (bone cancer induction by radium, lung cancer induction by radon daughter products, liver cancer and leukaemia following the use of Thorotrast, thyroid cancer; other site of cancer induction by radionuclides) [fr

  1. Ventricular dysfunction in children with obstructive sleep apnea: radionuclide assessment

    International Nuclear Information System (INIS)

    Tal, A.; Leiberman, A.; Margulis, G.; Sofer, S.

    1988-01-01

    Ventricular function was evaluated using radionuclide ventriculography in 27 children with oropharyngeal obstruction and clinical features of obstructive sleep apnea. Their mean age was 3.5 years (9 months to 7.5 years). Conventional clinical assessment did not detect cardiac involvement in 25 of 27 children; however, reduced right ventricular ejection fraction (less than 35%) was found in 10 (37%) patients (mean: 19.5 +/- 2.3% SE, range: 8-28%). In 18 patients wall motion abnormality was detected. In 11 children in whom radionuclide ventriculography was performed before and after adenotonsillectomy, right ventricular ejection fraction rose from 24.4 +/- 3.6% to 46.7 +/- 3.4% (P less than 0.005), and in all cases wall motion showed a definite improvement. In five children, left ventricular ejection fraction rose greater than 10% after removal of oropharyngeal obstruction. It is concluded that right ventricular function may be compromised in children with obstructive sleep apnea secondary to adenotonsillar hypertrophy, even before clinical signs of cardiac involvement are present

  2. Positive ventriculography and computer assisted tomography of the skull in the evaluation of megalocephaly in newborns and infants

    International Nuclear Information System (INIS)

    Kellermann, K.; Heuser, L.; Bliesener, J.A.

    1979-01-01

    To clarify indications and limits of computer assisted tomography and positive ventriculography the results of both methods were compared with each other retrospectively in 55 macrocephalic newborns and infants. It could be shown that positive ventriculography, even if combined with coronal views, was superseded by computer assisted tomography to only a certain extent. To complete the appropriate diagnosis preoperatively positive ventriculography was necessary most often in patients with paranatal disturbances who had undergone intensive care treatment. The non-invasive method of computer assisted tomography often yielded sufficient information on localisation, size, and nature of the underlying pathologic process. Both methods turned out to be complementary when topographical and functional interrelations of cranial cysts were to be analysed, or when anatomical details had to be demonstrated, especially structures of the midline and of the posterior fossa, which could not be visualized by computer assisted tomography alone. (orig.) [de

  3. Radionuclide cisternography

    International Nuclear Information System (INIS)

    Song, H.H.

    1980-01-01

    The purpose of this thesis is to show that radionuclide cisternography makes an essential contribution to the investigation of cerebrospinal fluid (CSF) dynamics, especially for the investigation of hydrocephalus. The technical details of radionuclide cisternography are discussed, followed by a description of the normal and abnormal radionuclide cisternograms. The dynamics of CFS by means of radionuclide cisternography were examined in 188 patients in whom some kind of hydrocephalus was suspected. This study included findings of anomalies associated with hydrocephalus in a number of cases, such as nasal liquorrhea, hygromas, leptomeningeal or porencephalic cysts. The investigation substantiates the value of radionuclide cisternography in the diagnosis of disturbances of CSF flow. The retrograde flow of radiopharmaceutical into the ventricular system (ventricular reflux) is an abnormal phenomenon indicating the presence of communicating hydrocephalus. (Auth.)

  4. Clinical experience with a non-ionic contrast medium (ultravist) in left ventriculography

    International Nuclear Information System (INIS)

    Lee, Ghi Jai; Park, Jae Hyung; Soe, Gwy Suk; Hong, Ju Hee; Han, Man Chung

    1988-01-01

    Non-ionic contrast medium, iopromide (Ultravist), was compared with ionic contrast medium, ioxitalamate (Telebrix), for efficacy and safety in 63 patients undergoing left ventriculography. In all patients, adverse symptoms and signs including pain, heat sense, nausea, vomiting, etc., were checked during and shortly after the injection. Blood pressure, heart rate, EKG and left ventricular pressure were also monitored during the study, and CBC, UA, BUN and creatinine were checked before and 24 hours after the study. The cineangiographic films were analysed and compared by 2 radiologists for the quality. Serious adverse effect did not occur in any case. Minor effects, especially nausea, were lee frequently caused by non-ionic contrast medium than by ionic contrast medium, and heat sense to non-ionic contrast medium was less severe than to ionic contrast medium. Except slightly elevated LVEDP at 1,5 minutes after the study in patients given ionic contrast medium, there was no significant change of electrophysiologic parameters and laboratory findings in both groups. In regard to image quality, there was no significant difference between ionic and non-ionic contrast medium. Thus non-ionic contrast medium, iopromide, appears to be safer for use in left ventriculography than the conventional ionic contrast medium, particularly in those patients at high risk of adverse effects.

  5. Radionuclide carrier

    International Nuclear Information System (INIS)

    Hartman, F.A.; Kretschmar, H.C.; Tofe, A.J.

    1978-01-01

    A physiologically acceptable particulate radionuclide carrier is described. It comprises a modified anionic starch derivative with 0.1% to 1.5% by weight of a reducing agent and 1 to 20% by weight of anionic substituents

  6. Phase analysis of regional and global ventricular contraction patterns in Wolff-Parkinson-White syndrome. Assessment by radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Koyama, Takao; Ichikawa, Takehiko and others

    1989-04-01

    Multigated blood pool scintigraphy was performed in 20 normal subjects and 39 patients with various intraventricular conduction abnormalities, including 25 patients with Wolff-Parkinson-White (WPW) syndrome. Cardiac imaging was performed in the modified left anterior oblique, right anterior oblique, and left lateral projections. In WPW syndrome, early contraction sites which were not seen in normal subjects were detected at the ventricular base in phase images. These anomalous early contraction sites disappeared after successful suppression of conduction through an accessory pathway by intravenous procainamide. These sites are believed to correspond to the location of the bundle of Kent and were consistent with the electrocardiographic findings. Phase mapping is a suitable noninvasive method to locate the position of the bundle of Kent and evaluate the ventricular contraction pattern in WPW syndrome and other intraventricular conduction abnormalities. (author).

  7. Radionuclide data

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Chapter 8 presents tables on selected alpha, beta, gamma and x-ray emitters by increasing energy; information on specific activity for selected radionuclides; naturally occurring radionuclides; the natural decay series; and the artificially produced neptunium series. A table of alpha emitters is listed by increasing atomic number and by energy. The table of β emitters presented is useful in identifying β emitters whose energies and possibly half-lives have been determined by standard laboratory techniques. It is also a handy guide to β-emitting isotopes for applications requiring specific half-lives and/or energies. Gamma rays for radionuclides of importance to radiological assessments and radiation protection are listed by increasing energy. The energies and branching ratios are important for radionuclide determinations with gamma spectrometry detectors. This section also presents a table of x-ray energies which are useful for radiochemical analyses. A number of nuclides emit x-rays as part of their decay scheme. These x-rays may be counted with Ar proportional counters, Ge planar or n-type Ge co-axial detectors, or thin crystal NaI(T1) scintillation counters. In both cases, spectral measurements can be made and both qualitative and quantitative information obtained on the sample. Nuclear decay data (energy and probability by radiation type) for more than one hundred radionuclides that are important to health physicists are presented in a schematic manner

  8. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1983-01-01

    The status of radionuclide generators for chemical research and applications related to the life sciences and biomedical research are reviewed. Emphasis is placed upon convenient, efficient and rapid separation of short-lived daughter radionuclides in a chemical form suitable for use without further chemical manipulation. The focus is on the production of the parent, the radiochemistry associated with processing the parent and daughter, the selection and the characteristic separation methods, and yields. Quality control considerations are briefly noted. The scope of this review includes selected references to applications of radionuclide generators in radiopharmaceutical chemistry, and the life sciences, particularly in diagnostic and therapeutic medicine. The 99 Mo-sup(99m)Tc generator was excluded. 202 references are cited. (orig.)

  9. A prospective comparison between three-dimensional magnetic resonance imaging and ventriculography for target-coordinate determination in frame-based functional stereotactic neurosurgery

    NARCIS (Netherlands)

    Schuurman, P. R.; de Bie, R. M.; Majoie, C. B.; Speelman, J. D.; Bosch, D. A.

    1999-01-01

    OBJECT: The purpose of this prospective study was to compare stereotactic coordinates obtained with ventriculography with coordinates derived from stereotactic computer-reconstructed three-dimensional magnetic resonance (3D-MR) imaging in functional stereotactic procedures. METHODS: In 15

  10. Noninvasive assessment of right ventricular wall motion by radionuclide cardioangiography

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Naito, Hiroaki; Hayashida, Kohei; Kozuka, Takahiro

    1981-01-01

    Radionuclide cardioangiography is a useful method to evaluate the left ventricular wall motion in various heart diseases. It has been also attempted to assess the right ventricular wall motion simultaneously by radionuclide method. In this study, using the combination of first-pass (RAO 30 0 ) and multi-gate (LAO 40 0 ) method, the site of right vetricle was classified in five. (1 inflow, 2 sinus, 3 outflow, 4 septal, 5 lateral) and the degree of wall motion was classified in four stages (dyskinesis, akinesis, hypokinesis, normal) according to the AHA committee report. These methods were applied clinically to forty-eight patients with various heart diseases. In the cases with right ventricular pressure or volume overload such as COLD, pulmonary infarction, the right ventricle was dilated and the wall motion was reduced in all portions. Especially, in the cases with right ventricular infarction, the right ventricular wall motion was reduced in the infarcted area. The findings of radionuclide method were in good agreement with those of contrast right ventriculography or echocardiography. In conclusion, radionuclide cardioangiography is a useful and noninvasive method to assess not only the left but also the right ventricular wall motion. (author)

  11. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wollongong Univ.; Tomiyoshi, K.; Sekine, T.

    1997-01-01

    The present status and future directions of research and development on radionuclide generator technology are reported. The recent interest to develop double-neutron capture reactions for production of in vivo generators; neutron rich nuclides for radio-immunotherapeutic pharmaceuticals: and advances with ultra-short lived generators is highlighted. Emphasis is focused on: production of the parent radionuclide; the selection and the evaluation of support materials and eluents with respect to the resultant radiochemical yield of the daughter, and the breakthrough of the radionuclide parent: and, the uses of radionuclide generators in radiopharmaceutical chemistry, biomedical and industrial applications. The 62 Zn → 62 Cu, 66 Ni → 66 Cu, 103m Rh → 103 Rh, 188 W → 188 Re and the 225 Ac → 221 Fr → 213 Bi generators are predicted to be emphasized for future development. Coverage of the 99 Mo → 99m Tc generator was excluded, as it the subject of another review. The literature search ended June, 1996. (orig.)

  12. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  13. Proficiency testing for radionuclides

    International Nuclear Information System (INIS)

    Faanhof, A.; Kotze, O.; Louw, I.

    2010-01-01

    Proficiency testing in general is only useful when it suites a certain purpose. With regards to radionuclides basically three fields of interest can be identified: (I)Foodstuffs-Introduced in the early 1960's to monitor the fall-out of nuclear tests and eventually the pathway to foodstuffs fit for human consumption. The demand for analysis increased substantially after the Chernobyl accident. (II) Natural radioactivity-Associated with mining and mineral processing of uranium and thorium baring mineral resources throughout the world where the radionuclides from the natural uranium and thorium decay series are found to pose concern for professional and public exposure. (III) Artificial radioactivity-This category covers mostly the long-lived nuclides generated by nuclear fission of the fuel used in nuclear power plants, research reactors and nuclear bomb tests. All three categories require a specific approach for laboratories to test their ability to analyze specific radio nuclides of interest in a variety of matrices. In this lecture I will give a compiled overview of the required radioanalytical skills, analysis sensitivity needed and radionuclides of interest, with more specific emphasis on QAQC of water sources and the recommended monitoring approach. And provide information on available reference materials and organizations/institutes that provide regular exercises for participating laboratories. I will also briefly communicate on the advantages and disadvantages of ISO/IEC 17025 accreditation for test laboratories, which is these days a prerequisite in national and international trade especially where foodstuffs and mineral products are concerned.

  14. Radionuclide study for cardiac lesion in Duchenne muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Oguni, Hirokazu; Osawa, Makiko; Shishikura, Keiko

    1985-12-01

    Tl-201 myocardial scintigraphy and radionuclide ventriculography with Tc-99m were performed in 10 patients with Duchenne muscular dystropohy (DMD) and 2 siblings with Becker muscular dystrophy (BMD). Perfusion defect especially in the left ventricular posterolateral wall (LVPLW) and cardiac apex was seen on Tl-201 imaging in 6 of the DMD patients and one of the BMD patients. For these patients, Tc-99m imaging also showed left ventricular local wall motion abnormality in 5 patients and a decreased left ventricular ejection fraction in 4 patients. These findings coincided well with fibrosis of the LVPLW found on autopsy. There were individual differences regarding the occurrence of cardiac complications. One of the BMD patients, as well as DMD patients, had also cardiac complications which have long been considered less common. (Namekawa, K.).

  15. Radionuclide study for cardiac lesion in Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Oguni, Hirokazu; Osawa, Makiko; Shishikura, Keiko

    1985-01-01

    Tl-201 myocardial scintigraphy and radionuclide ventriculography with Tc-99m were performed in 10 patients with Duchenne muscular dystropohy (DMD) and 2 siblings with Becker muscular dystrophy (BMD). Perfusion defect especially in the left ventricular posterolateral wall (LVPLW) and cardiac apex was seen on Tl-201 imaging in 6 of the DMD patients and one of the BMD patients. For these patients, Tc-99m imaging also showed left ventricular local wall motion abnormality in 5 patients and a decreased left ventricular ejection fraction in 4 patients. These findings coincided well with fibrosis of the LVPLW found on autopsy. There were individual differences regarding the occurrence of cardiac complications. One of the BMD patients, as well as DMD patients, had also cardiac complications which have long been considered less common. (Namekawa, K.)

  16. Radionuclide examinations

    International Nuclear Information System (INIS)

    Lentle, B.C.

    1989-01-01

    This paper reports on radionuclide examinations of the pancreas. The pancreas, situated retroperitonally high in the epigastrium, was a particularly difficult organ to image noninvasively before ultrasonography and computed tomography (CT) became available. Indeed the organ still remains difficult to examine in some patients, a fact reflected in the variety of methods available to evaluate pancreatic morphology. It is something of a paradox that the pancreas is metabolically active and physiologically important but that its examination by radionuclide methods has virtually ceased to have any role in day-to-day clinical practice. To some extent this is caused by the tendency of the pancreas's commonest gross diseases emdash carcinoma and pancreatitis, for example emdash to result in nonfunction of the entire organ. Disorders of pancreatic endocrine function have generally not required imaging methods for diagnosis, although an understanding of diabetes mellitus and its nosology has been advanced by radioimmunoassay of plasma insulin concentrations

  17. Radionuclide transfer

    International Nuclear Information System (INIS)

    Gerber, G.B.

    1993-01-01

    The research project described here had the aim to obtain further information on the transfer of nuclides during pregnancy and lactation. The tests were carried out in mini-pigs and rats receiving unchanging doses of radionuclides with the food. The following findings were revealed for the elements examined: Fe, Se, Cs and Zn were characterized by very high transfer levels in the mother, infant and foetus. A substantial uptake by the mother alone was observed for Co, Ag and Mn. The uptake by the foetus and infant here was 1 to 10 times lower. A preferential concentration in certain tissues was seen for Sr and Tc; the thyroid levels of Tc were about equally high in mothers and infants, while Sr showed less accumulation in the maternal bone. The lanthanide group of substances (Ce, Eu and Gd as well as Y and Ru) were only taken up to a very limited extent. The uptake of the examined radionuclides (Fe, Co, Ag, Ce) with the food ingested was found here to be ten times greater in rats as compared to mini-pigs. This showed that great caution must be observed, if the behaviour of radionuclides in man is extrapolated from relevant data obtained in rodents. (orig./MG) [de

  18. Characteristics of 201Tl myocardial SPECT and left ventriculography in patients with acute diagonal branch myocardial infarction

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori; Katou, Kazuzo; Ogasawara, Ken; Kirigaya, Hajime

    1993-01-01

    Characteristics of 201 Tl myocardial SPECT and ventriculography were studied in 13 patients with acute diagonal branch myocardial infarction. Rest 201 Tl myocardial SPECT and left ventriculography were underwent in chronic phase. In 5 patients electrocardiogram (ECG) changes in acute phase were not definite. In 6 patients it was difficult to identify the obstructed coronary artery with coronary angiography in acute phase. Mean value of maximum creatine phosphokinese (CPK) was 854 (458-1,774) U/l. It seemed to be difficult to diagnose acute diagonal branch myocardial infarction with ECG and/or coronary angiography. In all patients defects were noted on 201 Tl SPECT. Defects were small and noted in the central anterior wall and not in the septum. In 2 patients defects were noted at apex. In left ventriculography dyskinetic motion was noted in 10 patients; one patient showed apical aneurysm and 3 patients showed anterior wall aneurysm. In 3 patients anterior wall showed akinesis. It was concluded that 201 Tl myocardial SPECT were useful for detecting diagonal branch lesion. In case of diagonal branch myocardial infarction size of defects were small and defects were not noted in the septum, however aneurysmal motion was frequently noted. (author)

  19. Radionuclide radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.; Bradley, K.M.

    2006-01-01

    This is the fourth in a series of short reviews of internet-based radiological educational resources, and will focus on radionuclide radiology and nuclear medicine. What follows is a list of carefully selected websites to save time in searching them out. Most of the sites cater for trainee or non-specialist radiologists, but may also be of interest to specialists for use in teaching. This article may be particularly useful to radiologists interested in the rapidly expanding field of positron emission tomography computed tomography (PET-CT). Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (February 2006)

  20. The applicability and limitations of the geochemical models and tools used in simulating radionuclide behaviour in natural waters. Lessons learned from the Blind Predictive Modelling exercises performed in conjunction with Natural Analogue studies

    International Nuclear Information System (INIS)

    Bruno, J.; Duro, L.; Grive, M.

    2001-07-01

    One of the key applications of Natural Analogue studies to the Performance Assessment (PA) of nuclear waste disposal has been the possibility to test the geochemical models and tools to be used in describing the migration of radionuclides in a future radioactive waste repository system. To this end, several geochemical modelling testing exercises (commonly denoted as Blind Predictive Modelling), have formed an integral part of Natural Analogue Studies over the last decade. Consequently, we thought that this is a timely occasion to make an evaluation of the experience gained and lessons learnt. We have reviewed, discussed and compared the results obtained from the Blind Prediction Modelling (BPM) exercises carried out within 7 Natural Analogue Studies: Oman, Pocos de Caldas, Cigar Lake, Maqarin, El Berrocal, Oklo and Palmottu. To make this comparison meaningful, we present the main geochemical characteristics of each site in order to highlight the most relevant mineralogical and hydrochemical differences. From the complete list of elements studied at all the investigated sites we have made a selection based on the relevance of a given element from a PA viewpoint and on the frequency this element has been included in the BPM exercises. The elements selected for discussion are: Sr, Ba, Sn, Pb, Se, Ni, Zn, REEs, Th and U. We have based our discussion on the results obtained from the speciation as well as solubility calculations. From the comparison of the results it is concluded that we can differentiate between three element categories: 1. Elements whose geochemical behaviour can be fairly well described by assuming solubility control exerted by pure solid phases of the given element (i.e. Th, U under reducing conditions and U in some sites under oxidising conditions); 2. Elements for which the association to major geochemical components of the system must be considered in order to explain their concentrations in groundwaters (i.e. Sr, Ba, Zn, Se, REEs and U under

  1. Cardiac involvement of progressive muscular dystrophy (Becker type, Limb-girdle type and Fukuyama type) evaluated by radionuclide method

    International Nuclear Information System (INIS)

    Nagamachi, Shigeki; Inoue, Kenjiro; Jinnouchi, Seishi; Hoshi, Hiroaki; Ono, Seiji; Ohnishi, Takashi; Futami, Shigemi; Watanabe, Katsushi; Hayashi, Tohru

    1994-01-01

    Tl-201 SPECT and Tc-99m-Human serum albumin (HSA) multigated radionuclide ventriculography were performed on 11 patients with progressive muscular dystrophy (Becker type 2, Fukuyama type 2, Limb-girdle type 7) to evaluate myocardial involvement. Hypoperfusion was detected in 8 patients on Tl-201 SPECT. Decreases in both systolic function (left ventricular ejection fraction; LVEF) and diastolic function (peak filling rate; PFR) were also seen in these patients. A high incidence of myocardial involvement of these kinds of progressive muscular dystrophy was suggested. (author)

  2. Cardiac involvement of progressive muscular dystrophy (Becker type, Limb-girdle type and Fukuyama type) evaluated by radionuclide method

    Energy Technology Data Exchange (ETDEWEB)

    Nagamachi, Shigeki; Inoue, Kenjiro; Jinnouchi, Seishi; Hoshi, Hiroaki; Ono, Seiji; Ohnishi, Takashi; Futami, Shigemi; Watanabe, Katsushi; Hayashi, Tohru [Miyazaki Medical Coll., Kiyotake (Japan)

    1994-02-01

    Tl-201 SPECT and Tc-99m-Human serum albumin (HSA) multigated radionuclide ventriculography were performed on 11 patients with progressive muscular dystrophy (Becker type 2, Fukuyama type 2, Limb-girdle type 7) to evaluate myocardial involvement. Hypoperfusion was detected in 8 patients on Tl-201 SPECT. Decreases in both systolic function (left ventricular ejection fraction; LVEF) and diastolic function (peak filling rate; PFR) were also seen in these patients. A high incidence of myocardial involvement of these kinds of progressive muscular dystrophy was suggested. (author).

  3. Regional rates of myocardial fatty acid metabolism: Comparison with coronary angiography and ventriculography

    International Nuclear Information System (INIS)

    Schad, N.; Vattimo, A.; Bertelli, P.

    1990-01-01

    In 50 patients, 1 mCi 123 I phenylpentadecanoic acid (IPPA) was injected at peak ergometric stress and 1500 frames were acquired (1 frame/s) with a high count rate gamma camera. Parametric images of rates of decrease and increase for different time intervals after stress were compared with coronary angiography and LV ventriculography, separately evaluating the 3 main coronary territories: 18/150 territories supplied by normal coronaries presented rather homogeneous regional clearing rates, whereas a gradual decrease in clearing rates towards the end of the territory (frequently with peripheral defects) was seen in all 87/150 territories with significant coronary narrowing. In local correspondence to clearing defects, initial IPPA accumulations could be observed with later onset of clearing between 10 and 25 min. In all 44/150 territories presented abnormal clearing rates, mostly with a patchy pattern, with normal coronary anatomy, but all except one had LV dysfunction and a clinical diagnosis of cardiomyopathy, diabetes mellitus or hypertensive disease. Twenty four of the 41 patients with CAD had, in correspondence to a prior myocardial infarction, minimum or missing metabolic activity frequently in circumscribed zones, partly separated by bridges of still viable tissue with preserved but reduced clearing rates. (orig.)

  4. Regional rates of myocardial fatty acid metabolism: comparison with coronary angiography and ventriculography.

    Science.gov (United States)

    Schad, N; Wagner, R K; Hallermeier, J; Daus, H J; Vattimo, A; Bertelli, P

    1990-01-01

    In 50 patients, 1 mCi 123I phenylpentadecanoic acid (IPPA) was injected at peak ergometric stress and 1500 frames were acquired (1 frame/s) with a high count rate gamma camera. Parametric images of rates of decrease and increase for different time intervals after stress were compared with coronary angiography and LV ventriculography, separately evaluating the 3 main coronary territories: 18/150 territories supplied by normal coronaries presented rather homogeneous regional clearing rates, whereas a gradual decrease in clearing rates towards the end of the territory (frequently with peripheral defects) was seen in all 87/150 territories with significant coronary narrowing. In local correspondence to clearing defects, initial IPPA accumulations could be observed with later onset of clearing between 10 and 25 min. 44/150 territories presented abnormal clearing rates, mostly with a patchy pattern, with normal coronary anatomy, but all except one had LV dysfunction and a clinical diagnosis of cardiomyopathy, diabetes mellitus or hypertensive disease. Twenty four of the 41 patients with CAD had, in correspondence to a prior myocardial infarction, minimum or missing metabolic activity frequently in circumscribed zones, partly separated by bridges of still viable tissue with preserved but reduced clearing rates.

  5. Significance of blood-pool scintigraphy and echocardiography in the investigation of left heart ventricle. Stellung von Herzbinnenraumszintigraphie (HBR) und Echokardiographie (Echo) bei der Untersuchung des linken Ventrikels (LV)

    Energy Technology Data Exchange (ETDEWEB)

    Otto, L.; Neumann, G.; Koegler, A.; Wuensche, A.; Schneider, G. (Leipzig Univ., Klinik fuer Radiologie (Germany)); Krosse, B.; Rother, T.; Loebe, M.; Otto, J. (Leipzig Univ., Klinik fuer Innere Medizin (Germany))

    1990-01-01

    Left ventricular ejection (LVEF) was assessed by both radionuclide ventriculography and echocardiography. The correlation coefficient of 0.74 revealed a just good agreement. It was better in the range of normal than of pathological values. The analysis of regional wall motion performed by echocardiography was not as reliable as by radionuclide ventriculography. The main advantage of echocardiography is its good spatial resolution. Its domain is the diagnostics of pathomorphological changes including valvular disorders. Advantages of radionuclide ventriculography are good temporal resolution, registration of the third dimension, practicability during exercise and as bed side method (nuclear stethoscope). Functional disturbances of both ventricles are its field of application. (orig.).

  6. Significance of blood pool scintigraphy and echocardiography in the investigation of left heart ventricle

    International Nuclear Information System (INIS)

    Otto, L.; Krosse, B.; Neumann, G.; Rother, T.; Loebe, M.; Otto, J.; Koegler, A.; Wuensche, A.; Schneider, G.

    1990-01-01

    Left ventricular ejection (LVEF) was assessed by both radionuclide ventriculography and echocardiography. The correlation coefficient of 0.74 revealed a just good agreement. It was better in the range of normal than of pathological values. The analysis of regional wall motion performed by echocardiography was not as reliable as by radionuclide ventriculography. The main advantage of echocardiography is its good spatial resolution. Its domain is the diagnosis of pathomorphological changes including valvular disorders. Advantages of radionuclide ventriculography are good temporal resolution, registration of the third dimension practicability during exercise and as bedside method (nuclear stethoscope). Functional disturbances of both ventricles are its field of application. (author)

  7. Assessment of left ventricular function at different levels of exercise using gold-195m in asymptomatic diabetics

    International Nuclear Information System (INIS)

    Fazio, F.; Margonato, A.; Gerundini, P.; Vicedomini, G.; Gilardi, M.C.; Fregoso, A.; Bencivelli, W.; Milanesi, L.; Pozza, G.

    1985-01-01

    Left ventricular ejection fraction (LVEF) was evaluated by gold-195m first pass ventriculography in 10 diabetic patients with microangiopathy, in 10 diabetics without any complications, and in 10 healthy controls during maximum exercise. No differences among groups were present at rest, but at maximal exercise LVEF was significantly lower in microangiopathic patients than in the other two groups. Also muscle blood flow measured by xenon-133 washout was significantly lower during exercise in microangiopathic subjects. Small-vessel involvement of myocardium and muscle could play a role in the development of cardiovascular abnormalities during exercise in diabetics

  8. Selective coronarography and ventriculography with Iopamidol in the acute phase of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ricci Maccarini, P; Benenati, P M; Bellanti, G; Piscitelli, G

    1988-01-01

    The new techniques for an early treatement of acute myocardial infarction (AMI), such as thrombolysis and percutaneous transluminal angioplasty, often necessitate rapid and accurate radiological evaluation of coronaric lesions and left ventricular function. The aim of the present study was to evaluate both safety and tolerability of selective coronarography (SC) and left ventriculography (LVG), with iopamidol 370 mg I/ml as a contrast medium, in the acute phase of AMI. Thirty-nine patients aged 26-29 years, were examined: 18 group A, within 4 days (mean 2.6+-0.8 SD) and 21, group B, within 5-15 days after AMI (mean 8.8+-3 SD). Contrast media (cm) dosage varied from 150 to 300 ml (2.43-5.5 ml/bw). During the procedure, ECG was continuosly recorded; left ventricular pressure was registered immediately and 30 minutes after cm administration. During the following 9 days ECG tracings and plasmatic cytolysisenzymes were monitored. During the examination no patient complained of any symptoms. After LVG slight elevations in end diastolic pressure were detected in all patients (mean increase 4.7 mmHg), which were not relevant from a clinical point of view. In 11/39 cases ventricular tachycardia was observed, which spontaneously ceased. During SC no change in ECG tracings was registered except in one patient, group A, in whom complete transitory heart block was detected. After SC no alteration in instrumental and biochemical parameters was registered except in one patient, group B, in whom a reinfarction due to right coronaric artery occlusion was observed. In conclusion, these results suggest that both SC and LVG with iopamidol are safe techniques also in the early phase of myocardial infarction. 24 refs.

  9. Radionuclide stroke count ratios for assessment of right and left ventricular volume overload in children

    International Nuclear Information System (INIS)

    Parrish, M.D.; Graham, T.P. Jr.; Born, M.L.; Jones, J.P.; Boucek, R.J. Jr.; Artman, M.; Partain, C.L.

    1983-01-01

    The ratio of left ventricular to right ventricular stroke counts measured by radionuclide angiography has been used in adults to estimate the severity of left-sided valvular regurgitation. The validation of this technique in children for assessment of right and left ventricular volume overload is reported herein. Radionuclide stroke count ratios in 60 children aged 0.5 to 19 years (mean 11) were determined. Based on their diagnoses, the patients were divided into 3 groups: (1) normal--40 patients with no shunts or valvular regurgitation, (2) left ventricular volume overload--13 patients with mitral or aortic regurgitation, or both, and (3) right ventricular volume overload--7 patients, 2 with severe tricuspid regurgitation, 3 with atrial septal defects, and 2 with total anomalous pulmonary venous drainage. The radionuclide stroke count ratio clearly differentiated these groups (p less than 0.05): normal patients had a stroke count ratio of 1.04 +/- 0.17 (mean +/- 1 standard deviation), the left ventricular volume overload group had a stroke count ratio of 2.43 +/- 0.86, and the right ventricular volume overload group had a stroke count ratio of 0.44 +/- 0.17. In 22 of our 60 patients, radionuclide stroke count ratios were compared with cineangiographic stroke volume ratios, resulting in a correlation coefficient of 0.88. It is concluded that radionuclide ventriculography is an excellent tool for qualitative and quantitative assessment of valvular regurgitation in children

  10. Evaluation of left ventricular function during exercise in patients with ischemic heart disease using multigated blood pool scintigraphy

    International Nuclear Information System (INIS)

    Ohmori, Yoshiaki; Kanoh, Yasushi; Shiotani, Hideyuki; Fujitani, Kazuhiro; Fukuzaki, Hisashi; Kajiya, Teishi; Nakashima, Yoshiharu; Maeda, Kazumi.

    1985-01-01

    Multigated blood pool scintigraphy (exercise RI ventriculography) and exercise stress thallium-201 myocardial scintigraphy were performed in 44 ischemic heart disease (IHD) patients (16 with angina pectoris and 28 with old myocardial infarction) and 11 healthy persons. Furthermore, blood circulation was examined in 38 of the subjects. Work load was significantly greater, and the number of diseased vessels and the incidence of indicators for transient ischemia during exercise were significantly lower in the group with a remarkably increased left ventricular ejection fraction (EF) during exercise than in the group with a remarkably decreased EF. In the group with unchanged EF, reginal left ventricular wall movement could be assessed using phase analysis. In IHD patients with a remarkably decreased EF at rest, EF was scarcely changed during exercise, and indicators for transient ischemia were not observed frequently. There was a highly significnat correlation between EF during exercise and pulmonary artery wedge pressure or cardiac index during exercise, suggesting that EF is a noninvasive indicator for coronary circulation during exercise. Exercise RI ventriculography was considered useful for evaluating the physiology of IHD. (Namekawa, K.)

  11. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Allen, S.E.; Horrill, A.D.; Howard, B.J.; Lowe, V.P.W.; Parkinson, J.A.

    1983-07-01

    The subject is discussed under the headings: concentration and spatial distribution of radionuclides in grazed and ungrazed saltmarshes; incorporation of radionuclides by sheep grazing on an estuarine saltmarsh; inland transfer of radionuclides by birds feeding in the estuaries and saltmarshes at Ravenglass; radionuclides in contrasting types of coastal pastures and taken up by individual plant species found in west Cumbria; procedures developed and used for the measurement of alpha and gamma emitters in environmental materials. (U.K.)

  12. Radionuclides migration or isolation?

    International Nuclear Information System (INIS)

    Toulhoat, P.; Grambow, B.; Simoni, E.

    2005-01-01

    After 20 years of research, the chemical behaviour of actinides and fission products in nuclear waste disposal environments is much better understood. Consistent thermodynamic data have been gathered and allow much more accurate previsions. Through the considerable development of analytical spectroscopy, including time resolved laser fluorescence and X ray absorption, a better understanding of the chemical reactivity (complexation, sorption) of actinides and fission products at a molecular scale has been possible. Chemically reducing conditions are found in most selected disposal host rock formations, generally chosen for their high sorption capacity (clays); such conditions favour the chemical confinement of most radionuclides through precipitation or sorption. Low permeability host rocks participate to this confinement, as convective fluxes are lower than diffusive fluxes. The most recent performance assessment exercises have taken into account the recent progress of knowledge in the chemical evolution of the near field. They show that the dose rates at the outlet are far lower than existing recommendations for normal and most altered evolution scenarios. (authors)

  13. Cerebrospinal fluid flow abnormalities in patients with neoplastic meningitis. An evaluation using 111In-DTPA ventriculography

    International Nuclear Information System (INIS)

    Grossman, S.A.; Trump, D.L.; Chen, D.C.; Thompson, G.; Camargo, E.E.

    1982-01-01

    Cerebrospinal fluid flow dynamics were evaluated by 111 In-diethylenetriamine pentaacetic acid ( 111 In-DTPA) ventriculography in 27 patients with neoplastic meningitis. Nineteen patients (70 percent) had evidence of cerebrospinal fluid flow disturbances. These occurred as ventricular outlet obstructions, abnormalities of flow in the spinal canal, or flow distrubances over the cortical convexities. Tumor histology, physical examination, cerebrospinal fluid analysis, myelograms, and computerized axial tomographic scans were not sufficient to predict cerebrospinal fluid flow patterns. These data indicate that cerebrospinal fluid flow abnormalities are common in patients with neoplastic meningitis and that 111 In-DTPA cerebrospinal fluid flow imaging is useful in characterizing these abnormalities. This technique provides insight into the distribution of intraventricularly administered chemotherapy and may provide explanations for treatment failure and drug-induced neurotoxicity in patients with neoplastic meningitis

  14. Measurement of left ventricular ejection fraction using gated 99mTc-sestamibi myocardial planar images: Comparison to contrast ventriculography

    International Nuclear Information System (INIS)

    Parker, D.A.; Lloret, R.L.; Barilla, F.; Douthat, L.; Gheorghiade, M.

    1991-01-01

    Using the new myocardial perfusion agent 99mTc-sestamibi and multigated acquisition on a nuclear medicine gamma camera, the left ventricular ejection fraction (LVEF) was derived in 13 patients with coronary artery disease (CAD). Cross-sectional activity profiles were used to measure the left ventricle from end-diastolic and end-systolic images. Several different geometric methods were then utilized to derive ejection fractions from the nuclear data. Comparison of the resultant ejection fractions to those obtained from contrast ventriculography showed significant correlation for all geometric methods (P less than 0.01, Sy X x = 6.2 to 9.6). The authors conclude that in patients with CAD one or more of these simple geometric methods can provide a useful estimate of the LVEF when performing 99mTc-sestamibi multigated myocardial perfusion imaging

  15. Determination of right ventricular ejection fraction from reprojected gated blood pool SPET: comparison with first-pass ventriculography

    International Nuclear Information System (INIS)

    Bartlett, M.L.; Seaton, D.; McEwan, L.; Fong, W.

    2001-01-01

    Gated blood pool (GBP) studies are widely available and relatively inexpensive. We have previously published a simple and convenient method for measuring left ventricle ejection fraction (EF) with increased accuracy from single-photon emission tomography (SPET) GBP scans. This paper describes an extension of this method by which right ventricular EF may also be measured. Gated SPET images of the blood pool are acquired and re-oriented in short-axis slices. Counts from the left ventricle are excluded from the short-axis slices, which are then reprojected to give horizontal long-axis images. Time-activity curves are generated from each pixel around the right ventricle, and an image is created with non-ventricular pixels ''greyed out''. This image is used as a guide in drawing regions of interest around the right ventricle on the end-diastolic and end-systolic long-axis images. In 28 patients, first-pass ventriculography studies were acquired followed by SPET GBP scans. The first-pass images were analysed a total of four times by two observers and the SPET images were analysed three times each by two observers. The agreement between the two techniques was good, with a correlation coefficient of 0.72 and a mean absolute difference between first-pass and reprojected SPET EFs of 4.8 EF units. Only four of the 28 patients had a difference of greater than 8 EF units. Variability was also excellent for SPET right ventricular EF values. Intra-observer variability was significantly lower for SPET than for first-pass EFs: standard error of the estimate (SEE)=5.1 and 7.3 EF units, respectively (P<0.05). Inter-observer variability was comparable in the two techniques (SEE=5.2 and 6.9 EF units for SPET and first-pass ventriculography, respectively). (orig.)

  16. Right ventricular ejection fraction - comparison of various angiographic and radionuclide approaches

    International Nuclear Information System (INIS)

    Schicha, H.; Tebbe, U.; Voth, E.; Sciagra, R.; Schultz, W.; Neuhaus, G.; Goettingen Univ.

    1987-01-01

    In 21 patients with various heart diseases RVEF was measured angiographically and by radionuclide ventriculography. Using biplane angiocardiography evaluation was performed by 7 different methods (Simpson's rule, Dogde, Arcilla, Ferlinz, Duebel). Using equilibrium RNV, evaluation was performed by 9 modifications of analysis. Problems were evident to separate the right atrium from the ventricle and to define the site of the pulmonary valve. The results show that when using the various methods of angiography considerable variations of the absolute volumes occur, but least so with RVEF. When using RNV with one single enddiastolic ROI, the RVEF was much too low. By means of the enddiastolic/endsystolic Double-ROI-method a good agreement with angiography was found, with correlation coefficients up to r=0.85. There was only a minor effect of background correction. (orig.) [de

  17. Measurement of absolute left ventricular volume by radionuclide angiography: a technical review

    International Nuclear Information System (INIS)

    Al-Khawaja, I.M.; Lahiri, Avijit; Raftery, E.B.; Medical Research Council, Harrow

    1988-01-01

    Absolute left ventricular volumes have important clinical implications in the evaluation of cardiac performance. Several invasive and noninvasive techniques have been reported, none of which can be considered ideal for this purpose. Contrast angiography, echocardiography and radionuclide ventriculography are open to criticism. Different radioisotopic approaches are described with emphasis on the importance of accurate separation of left ventricular activity, the selection of background activity, and the correction for photon attenuation by body tissues. Improper use of statistics and validation techniques have obscured the value of these techniques. In the absence of a 'gold standard' there should be a 'radioisotopic' left ventricular volume with established independent characteristics, repeatability and reproducibility by which new approaches can be judged. (author)

  18. Evaluation of right ventricular ejection fraction by first-pass radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Uehara, Toshiisa; Nishimura, Tsunehiko; Naito, Hiroaki; Hayashida, Kohei; Kozuka, Takahiro

    1981-01-01

    Left ventricular ejection fraction (LVEF) obtained by radionuclide angiocardiography is a convenient and good parameter of the left ventricular function. Right ventricular ejection fraction (RVEF) also seems to be a good parameter of the right ventricular function. RVEF calculated from volumetry with contrast right ventriculography is not necessarily correct because of the complex figure of the right ventricle. On the other hand, the method of calculation of RVEF with radionuclide angiocardiography has the advantage of being able to ignore the complexity of figure of RV, because RI counts extracted from the time-activity curve represent changes in ventricular volume. In this study, we developped an original method to calculate RVEF with first pass method. After setting of region of interest (ROI) of RV, background and ROI for correction of motion of tricuspid valve, we calculated RVEF with these time-activity curves, Since we found that too rapid infusion of RI made the time-activity curve of RV too steep, and too slow infusion of RI made the background of lung field too high, the appropriate infusion rate was required to get correct value of RVEF. In addition, the time-activity curve often became steep or flat in dependence of the speed of venous return and cardiac output of patients. In order to avoid the effect of infusion speed, the time-activity curve was fitted to linear curves and the value of RVEF was corrected. The validity of these methods was confirmed in our study. As the result, RVEF obtained with our methods appeared to have good correlation with that obtained from volumetry of contrast right ventriculography (r = 0.77) and to be very useful in clinical estimation of right ventricular function. (author)

  19. Speciation analysis of radionuclides

    International Nuclear Information System (INIS)

    Salbu, B.

    2010-01-01

    Full text: Naturally occurring and artificially produced radionuclides in the environment can be present in different physico-chemical forms (i. e. radionuclide species) varying in size (nominal molecular mass), charge properties and valence, oxidation state, structure and morphology, density, complexing ability etc. Low molecular mass (LMM) species are believed to be mobile and potentially bioavailable, while high molecular mass (HMM) species such as colloids, polymers, pseudocolloids and particles are considered inert. Due to time dependent transformation processes such as mobilization of radionuclide species from solid phases or interactions of mobile and reactive radionuclide species with components in soils and sediments, however, the original distribution of radionuclides deposited in ecosystems will change over time and influence the ecosystem behaviour. To assess the environmental impact from radionuclide contamination, information on radionuclide species deposited, interactions within affected ecosystems and the time-dependent distribution of radionuclide species influencing mobility and biological uptake is essential. The development of speciation techniques to characterize radionuclide species in waters, soils and sediments should therefore be essential for improving the prediction power of impact and risk assessment models. The present paper reviews fractionation techniques which should be utilised for radionuclide speciation purposes. (author)

  20. Quantitative radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Scholz, P.M.; Rerych, S.K.; Moran, J.F.; Newman, G.E.; Douglas, J.M.; Sabiston, D.C. Jr.; Jones, R.H.

    1980-01-01

    This study introduces a new method for calculating actual left ventricular volumes and cardiac output from data recorded during a single transit of a radionuclide bolus through the heart, and describes in detail current radionuclide angiocardiography methodology. A group of 64 healthy adults with a wide age range were studied to define the normal range of hemodynamic parameters determined by the technique. Radionuclide angiocardiograms were performed in patients undergoing cardiac catherization to validate the measurements. In 33 patients studied by both techniques on the same day, a close correlation was documented for measurement of ejection fraction and end-diastolic volume. To validate the method of volumetric cardiac output calcuation, 33 simultaneous radionuclide and indocyanine green dye determinations of cardiac output were performed in 18 normal young adults. These independent comparisons of radionuclide measurements with two separate methods document that initial transit radionuclide angiocardiography accurately assesses left ventricular function

  1. Kegel Exercises

    Science.gov (United States)

    ... exercised my pelvic muscles ____ times. I spent ____ minutes exercising. At each exercise session, I squeezed my pelvic ... exercised my pelvic muscles ____ times. I spent ____ minutes exercising. At each exercise session, I squeezed my pelvic ...

  2. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi

    2000-01-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V 2 , V 3 and V 4 leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV F , V 5 and V 6 leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  3. Marine biogeochemistry of radionuclides

    International Nuclear Information System (INIS)

    Fowler, S.W.

    1997-01-01

    Radionuclides entering the ocean from runoff, fallout, or deliberate release rapidly become involved in marine biogeochemical cycles. Sources, sinks and transport of radionuclides and analogue elements are discussed with emphasis placed on how these elements interact with marine organisms. Water, food and sediments are the source terms from which marine biota acquire radionuclides. Uptake from water occurs by surface adsorption, absorption across body surfaces, or a combination of both. Radionuclides ingested with food are either assimilated into tissue or excreted. The relative importance of the food and water pathway in uptake varies with the radionuclide and the conditions under which exposure occurs. Evidence suggests that, compared to the water and food pathways, bioavailability of sediment-bound radionuclides is low. Bioaccumulation processes are controlled by many environmental and intrinsic factors including exposure time, physical-chemical form of the radionuclide, salinity, temperature, competitive effects with other elements, organism size, physiology, life cycle and feeding habits. Once accumulated, radionuclides are transported actively by vertical and horizontal movements of organisms and passively by release of biogenic products, e.g., soluble excreta, feces, molts and eggs. Through feeding activities, particles containing radionuclides are ''packaged'' into larger aggregates which are redistributed upon release. Most radionuclides are not irreversibly bound to such particles but are remineralized as they sink and/or decompose. In the pelagic zones, sinking aggregates can further scavenge particle-reactive elements thus removing them from the surface layers and transporting them to depth. Evidence from both radiotracer experiments and in situ sediment trap studies is presented which illustrates the importance of biological scavenging in controlling the distribution of radionuclides in the water column. (author)

  4. Prevention: Exercise

    Medline Plus

    Full Text Available ... Core! Stretching/Flexibility Aerobic Exercise Cervical Exercise Strength Training for the Elderly ... Committee Exercise Committee Core Strengthening Many popular forms of exercise focus on ...

  5. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Bocock, K.L.

    1981-01-01

    This report summarizes information on the distribution and movement of radionuclides in semi-natural terrestrial ecosystems in north-west England with particular emphasis on inputs to, and outputs from ecosystems; on plant and soil aspects; and on radionuclides in fallout and in discharges by the nuclear industry. (author)

  6. Report on the intercomparison run IAEA-384. Radionuclides in Fangataufa lagoon sediment

    International Nuclear Information System (INIS)

    Povinec, P.P.; Pham, M.K.

    2000-01-01

    The accurate and precise determinations of radionuclide concentrations in marine samples are important aspects of marine radioactivity assessments and the use of radionuclides in studies of oceanographic processes. To address the problem of data quality, and to assist Member States in verifying the performance of their laboratories, the IAEA Marine Environment Laboratory (MEL) in Monaco has conducted intercomparison exercises on radionuclides in marine samples for many years as part of its contribution to the IAEA's programme of Analytical Quality Control Services (AQCS). For this intercomparison exercise, in 1996 IAEA-MEL collected sediment in Fangataufa lagoon, French Polynesia. The sample aliquots were distributed during 1997-1998 for intercomparison of anthropogenic and natural radionuclides. 110 laboratories worldwide agreed to participate. Of these, only 94 sent results which could be used in the evaluation of this intercomparison exercise. This report describes the results obtained from 94 laboratories on anthropogenic and natural radionuclide determinations in Fangataufa lagoon sediment

  7. Report on the intercomparison run IAEA-384. Radionuclides in Fangataufa lagoon sediment

    Energy Technology Data Exchange (ETDEWEB)

    Povinec, P P; Pham, M K

    2000-07-01

    The accurate and precise determinations of radionuclide concentrations in marine samples are important aspects of marine radioactivity assessments and the use of radionuclides in studies of oceanographic processes. To address the problem of data quality, and to assist Member States in verifying the performance of their laboratories, the IAEA Marine Environment Laboratory (MEL) in Monaco has conducted intercomparison exercises on radionuclides in marine samples for many years as part of its contribution to the IAEA's programme of Analytical Quality Control Services (AQCS). For this intercomparison exercise, in 1996 IAEA-MEL collected sediment in Fangataufa lagoon, French Polynesia. The sample aliquots were distributed during 1997-1998 for intercomparison of anthropogenic and natural radionuclides. 110 laboratories worldwide agreed to participate. Of these, only 94 sent results which could be used in the evaluation of this intercomparison exercise. This report describes the results obtained from 94 laboratories on anthropogenic and natural radionuclide determinations in Fangataufa lagoon sediment.

  8. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  9. Right and left cardiac function in HIV-infected patients investigated using radionuclide ventriculography and brain natriuretic peptide: a 5-year follow-up study

    DEFF Research Database (Denmark)

    Kristoffersen, U.S.; Lebech, A.M.; Gerstoft, J.

    2008-01-01

    ventricular ejection fraction (RVEF) and left ventricular ejection fraction (LVEF), as well as measurement of brain natriuretic peptide (BNP). Between July 2005 and January 2007, 63 patients (69%) agreed to participate in a follow-up study with a mean follow-up of 4.5 years. RESULTS: All patients had normal......, it seems that the improvement in immunocompetency and viral load has removed the problem of HIV-related cardiomyopathy. Although HAART has been suggested as a possible new cause of cardiomyopathy, we did not find any evidence of this Udgivelsesdato: 2008/3...

  10. Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Lebech, Anne-Mette; Hesse, Birger

    2005-01-01

    for evaluation of right-sided cardiac function. The aim of our study was to compare the agreement between these methods when measuring right-sided cardiac function. METHODS: Twenty-four healthy volunteers were included. Mean age was 44 years (range: 25-60) and 29% were females. All participants had FP, GBPS...

  11. Evaluation of aspirin therapy on intracardiac thrombi using indium-111-oxine platelet scintigraphy, two-dimentional echocardiography and left ventriculography

    International Nuclear Information System (INIS)

    Shibuya, Masanori; Irino, Tadayoshi; Yoshioka, Toshiharu; Sugimoto, Tsuyoshi; Tsuji, Kazuo; Naka, Masashi; Arai, Hidekazu.

    1984-01-01

    Left ventriculography (LVG), two-dimensional echocardiography (2-DE) and indium-111-oxine platelet scintigraphy were performed in five patients with intracardiac thrombi. Thrombi were visible in 7 sites (5 in the ventricle and 2 in the atrium) by platelet scintigraphy, in 4 sites (3 in the ventricle and 1 in the atrium) by 2-DE, and in 4 sites (4 in the ventricle) by LVG. When aspirin was administered to the patients, platelet scintigraphy had become negative for thrombi in 5 sites and false-negative for them in 2 sites. However, thrombi were detected in 6 sites after the withdrawal of aspirin. On the other hand, thrombi were detected in 4 sites by 2-DE, irrespective of the administration of aspirin. Indium-111-oxine platelet scintigraphy has proved to not only have higher sensitivity for detecting thrombi but also to be capable of observing the coagulation status of platelets on the thrombi. It is therefore considered very helpful in assessing anticoagulation therapy. (Namekawa, K)

  12. Process for encapsulating radionuclides

    International Nuclear Information System (INIS)

    Brownell, L.E.; Isaacson, R.E.

    1976-01-01

    Radionuclides are immobilized in virtually an insoluble form by reacting at a temperature of at least 90 0 C as an aqueous alkaline mixture having a solution pH of at least 10, containing a source of silicon, the radionuclide waste, and a metal cation. The molar ratio of silicon to the metal cation is on the order of unity to produce a gel from which complex metalosilicates crystallize to entrap the radionuclides within the resultant condensed crystal lattice. The product is a silicious stone-like material which is virtually insoluble and nonleachable in alkaline or neutral environment. One embodiment provides for the formation of the complex metalo-silicates, such as synthetic pollucite, by gel formation with subsequent calcination to the solid product; another embodiment utilizes a hydrothermal process, either above ground or deep within basalt caverns, at greater than atmospheric pressures and a temperature between 90 and 500 0 C to form complex metalo-silicates, such as strontium aluminosilicate. Another embodiment provides for the formation of complex metalo-silicates, such as synthetic pollucite, by slurrying an alkaline mixture of bentonite or kaolinite with a source of silicon and the radionuclide waste in salt form. In each of the embodiments a mobile system is achieved whereby the metalo-silicate constituents reorient into a condensed crystal lattice forming a cage structure with the condensed metalo-silicate lattice which completely surrounds the radionuclide and traps the radionuclide therein; thus rendering the radionuclide virtually insoluble

  13. Foodstuffs, radionuclides, monitoring

    International Nuclear Information System (INIS)

    Denisikov, A.I.

    2000-01-01

    Radionuclide contamination of water and food stuffs as a result of the Chernobyl accident and permissible contents of 90 Sr and 137 Cs are considered in brief. A method of radiation monitoring of food stuffs and water for the radionuclides mentioned is suggested. The method permits employment of the simplest and cheapest radiometric equipment for analysis, whole the high degree of radionuclide concentration using fiber sorbents permits using the instrumentation without expensive shields against external radiation. A description of ion-exchange unit for radiation monitoring of liquid samples of food stuffs or water, is provided [ru

  14. Generator for radionuclide

    International Nuclear Information System (INIS)

    Weisner, P.S.; Forrest, T.R.F.

    1985-01-01

    This invention provides a radionuclide generator of the kind in which a parent radionuclide, adsorbed on a column of particulate material, generates a daughter radionuclide which is periodically removed from the column. This invention is particularly concerned with technetium generators using single collection vials. The generator comprises a column, a first reservoir for the eluent, a second reservoir to contain the volume of eluent required for a single elution, and means connecting the first reservoir to the second reservoir and the second reservoir to the column. Such a generator is particularly suitable for operation by vacuum elution

  15. Radionuclides in analytical chemistry

    International Nuclear Information System (INIS)

    Tousset, J.

    1984-01-01

    Applications of radionuclides in analytical chemistry are reviewed in this article: tracers, radioactive sources and activation analysis. Examples are given in all these fields and it is concluded that these methods should be used more widely [fr

  16. Radionuclide Basics: Iodine

    Science.gov (United States)

    ... Centers Radiation Protection Contact Us Share Radionuclide Basics: Iodine Iodine (chemical symbol I) is a chemical element. ... in the environment Iodine sources Iodine and health Iodine in the Environment All 37 isotopes of iodine ...

  17. Abscess detection with radionuclides

    International Nuclear Information System (INIS)

    Alavi, J.B.

    1988-01-01

    Radionuclide studies may aid in the diagnosis and localization of intra-abdominal infections. Despite the introduction of new radiographic and ultrasound methods, there are several clinical situations in which radionuclide scans have proved useful. Those include detection of postoperative intra-abdominal abscess, evaluation of liver abscess, differentiation between pancreatic pseudocyst or abscess, evaluation of fever of unknown origin, and evaluation of inflammatory bowel disease. Each clinical situation is discussed separately here

  18. Quantitative Computed Tomography Ventriculography for Assessment and Monitoring of Hydrocephalus: A Pilot Study and Description of Method in Subarachnoid Hemorrhage.

    Science.gov (United States)

    Multani, Jasjit Singh; Oermann, Eric Karl; Titano, Joseph; Mascitelli, Justin; Nicol, Kelly; Feng, Rui; Skovrlj, Branko; Pain, Margaret; Mocco, J D; Bederson, Joshua B; Costa, Anthony; Shrivastava, Raj

    2017-08-01

    There is no facile quantitative method for monitoring hydrocephalus (HCP). We propose quantitative computed tomography (CT) ventriculography (qCTV) as a novel computer vision tool for empirically assessing HCP in patients with subarachnoid hemorrhage (SAH). Twenty patients with SAH who were evaluated for ventriculoperitoneal shunt (VPS) placement were selected for inclusion. Ten patients with normal head computed tomography (CTH) findings were analyzed as negative controls. CTH scans were segmented both manually and automatically (by qCTV) to generate measures of ventricular volume. The median manually calculated ventricular volume was 36.1 cm 3 (interquartile range [IQR], 30-115 cm 3 ), which was similar to the median qCTV measured volume of 37.5 cm 3 (IQR, 32-118 cm 3 ) (P = 0.796). Patients undergoing VPS placement demonstrated an increase in median ventricular volume on qCTV from 21 cm 3 to 40 cm 3 on day T-2 and to 51 cm 3 by day 0, a change of 144%. This is in contrast to patients who did not require shunting, in whom median ventricular volume decreased from 16 cm 3 to 14 cm 3 on day T-2 and to 13 cm 3 by day 0, with an average overall volume decrease 19% (P = 0.001). The average change in ventricular volume predicted which patients would require VPS placement, successfully identifying 7 of 10 patients (P = 0.004). Using an optimized cutoff of a change in ventricular volume of 2.5 cm 3 identified all patients who went on to require VPS placement (10 of 10; P = 0.011). qCTV is a reliable means of quantifying ventricular volume and hydrocephalus. This technique offers a new tool for monitoring neurosurgical patients for hydrocephalus, and may be beneficial for use in future research studies, as well as in the routine care of patients with hydrocephalus. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Correlation of heart rate and radionuclide index of left ventricular contraction and relaxation

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Inagaki, Suetsugu; Kubota, Yasushi; Nakagawa, Masao

    1990-01-01

    Since the cardiac function indices derived from radionuclide ventriculography (RNV) are considered to depend on the heart rate, we studied the relationship between systolic or diastolic indices and heart rates in patients with normal RNV and devised a method of correcting these indices according to the heart rate. For the systolic indices, the heart rate showed significant correlation with ET (r=-0.640), PER (r=0.791) and TPE (r=-0.401) but not with EF, 1/3 EF, MNSER or 1/3 MNSER. For the diastolic indices, the heart rate correlated well with FT (r=-0.938), RFT (r=-0.736), SFT (r=-0.803), 1/3 FF (r=-0.758), PFR (r=0.759), 1/3 PFR (r=0.742) and TPF (r=-0.389) but not with AFT, 1/3 MNDFR or AFF. These results indicate that many systolic and diastolic indices derived from RNV are affected by the heart rate, So when cardiac function is evaluated with the use of radionuclide indices, those which are independent of the heart rate should be used, or they should be corrected for the heart rate. As a method of correction, we proposed a rotating method obtained by manipulation of the regression equation of heart rates and indices. This new method is certain and easier to use when the correcting equations are set into a computer program. (author)

  20. Radionuclide fixation mechanisms in rocks

    International Nuclear Information System (INIS)

    Nakashima, S.

    1991-01-01

    In the safety evaluation of the radioactive waste disposal in geological environment, the mass balance equation for radionuclide migration is given. The sorption of radionuclides by geological formations is conventionally represented by the retardation of the radionuclides as compared with water movement. In order to quantify the sorption of radionuclides by rocks and sediments, the distribution ratio is used. In order to study quantitatively the long term behavior of waste radionuclides in geological environment, besides the distribution ratio concept in short term, slower radionuclide retention reaction involving mineral transformation should be considered. The development of microspectroscopic method for long term reaction path modeling, the behavior of iron during granite and water interaction, the reduction precipitation of radionuclides, radionuclide migration pathways, and the representative scheme of radionuclide migration and fixation in rocks are discussed. (K.I.)

  1. Radioactivity: radionuclides in foods

    International Nuclear Information System (INIS)

    Simpson, R.E.; Baratta, E.J.; Jelinek, C.F.

    1977-01-01

    The results are summarized of the analysis for strontium-90, cesium-137, iodine-131, ruthenium-106, and potassium-40, a naturally occurring radionuclide, in samples of total diet and selected import commodities in the foods compliance program of the Food and Drug Administration. On the basis of the radionuclide intake guidelines established by the Federal Radiation Council (FRC), the low content of radionuclides found in the total diet samples for fiscal years 1973 and 1974 demonstrates the need for surveillance only at the present level. The low levels of radionuclides found in a limited number of edible imported commodities indicate that their contribution to the total diet would not increase the levels of these radionuclides above those recommended for only periodic surveillance by the FRC. The potassium levels, determined from potassium-40 activity, found in meats and fish agree with the value for normal muscle tissue for the reference man reported by the International Commission on Radiation Protection. Of the other commodities, nuts contained the highest levels, while sugar, beverages, and processed foods contained the lowest levels of potassium. Although cesium and potassium are chemical analogs with similar metabolic properties, because of their variable content in some leafy samples as a result of surface contamination, a correlation between cesium-137 levels and the cesium-137-to-potassium ratio was inconclusive

  2. Osmium-191 → iridium-191m radionuclide generator: development and clinical application. Progress report, March 1, 1981-February 28, 1982

    International Nuclear Information System (INIS)

    Treves, S.; Cheng, C.

    1981-01-01

    A prototype osmium-191 (T 1/2 = 16 days) → iridium-191m (T 1/2 = 4.9 seconds) generator designed for first pass radionuclide angiography was developed in our laboratory (Os-191 → Ir-191m). Our generator had 14 to 20% Ir-191m yield and a 1 to 3 x 10 -3 % Os-191 breakthrough. Iridium-191m decays with emission of a 65 and a 129 keV photon in 50% and 25% abundance respectively. This radionuclide is advantageous for angiography since it provides higher photon flux and results in much lower radiation dose to the patient than Tc-99m. One objective of this research is to improve the Os-191 → Ir-191m generator for first pass radionuclide angiography at an increase in the Ir-191m yield and a decrease in the Os-191 breakthrough. In addition, we would like to develop an Os-191 → Ir-191m generator for continuous infusion which will be used for ECG gated blood pool ventriculography, venography, and arteriography. Another approach will be to develop a carrier free Os-191 → Ir-191m generator in combination with organic or inorganic exchangers. Iridium-191m from our current generator has been employed successfully in two patient studies for the quantitation left-to-right shunting and the measurement of right and left ventricular ejection fractions. These types of studies will be expanded and further evaluated

  3. Nuclear medical control of the efficiency of transluminal coronary angioplasty (TCA)

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Scherer, D.; Kober, G.; Maul, F.D.; Kanemoto, N.; Standke, R.; Hoer, G.; Kaltenbach, M.; Frankfurt Univ.

    1982-01-01

    To assess the results of transluminal coronary angioplasty 48 patients with coronary heart disease were investigated at rest and during exercise with the ECG (46 patients), thallium-201 myocardial scintigraphy (26 patients), and equilibrium radionuclide ventriculography (38 patients). Exercise stress test was quantified by means of an ischemia score, myocardial scintigraphy by an vitality index and by corresponding redistribution factors, and radionuclide ventriculography by ejection fraction and maximum systolic volume change as a fraction of enddiastolic volume. This, the results show, that in selected cases, TCA can achieve improved left ventricular function and perfusion comparable to that of aortocoronary bypass surgery. (orig./MG) [de

  4. Radionuclides in house dust

    CERN Document Server

    Fry, F A; Green, N; Hammond, D J

    1985-01-01

    Discharges of radionuclides from the British Nuclear Fuel plc (BNFL) reprocessing plant at Sellafield in Cumbria have led to elevated concentrations radionuclides in the local environment. The major routes of exposure of the public are kept under review by the appropriate Government departments and monitoring is carried out both by the departments and by BNFL itself. Recently, there has been increasing public concern about general environmental contamination resulting from the discharges and, in particular, about possible exposure of members of the public by routes not previously investigated in detail. One such postulated route of exposure that has attracted the interest of the public, the press and Parliament arises from the presence of radionuclides within houses. In view of this obvious and widespread concern, the Board has undertaken a sampling programme in a few communities in Cumbria to assess the radiological significance of this source of exposure. From the results of our study, we conclude that, alt...

  5. Radionuclides in foods

    International Nuclear Information System (INIS)

    1994-01-01

    This report contains data on the levels of radionuclides in the UK foodchain. Most data derive from monitoring programmes that exist around nuclear sites, and in some cases date back to the 1960s. Some comparative data from site operator and government-run programmes are included. Data from monitoring undertaken after the Chernobyl accident are summarised. General monitoring of the foodchain for both artificial and natural radionuclides, and the results of relevant government-sponsored research are also described. The report includes basic information on radioactivity in the environment, radiation protection standards and describes what measures are taken to routinely monitor the foodchain and assess public risk. (Author)

  6. Targeted Radionuclide Therapy

    Directory of Open Access Journals (Sweden)

    David Cheng

    2011-10-01

    Full Text Available Targeted radiotherapy is an evolving and promising modality of cancer treatment. The killing of cancer cells is achieved with the use of biological vectors and appropriate radionuclides. Among the many advantages of this approach are its selectiveness in delivering the radiation to the target, relatively less severe and infrequent side effects, and the possibility of assessing the uptake by the tumor prior to the therapy. Several different radiopharmaceuticals are currently being used by various administration routes and targeting mechanisms. This article aims to briefly review the current status of targeted radiotherapy as well as to outline the advantages and disadvantages of radionuclides used for this purpose.

  7. Targeted Radionuclide Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ersahin, Devrim, E-mail: devrimersahin@yahoo.com; Doddamane, Indukala; Cheng, David [Department of Diagnostic Radiology, School of Medicine, Yale University, 333 Cedar St., New Haven, CT 06520 (United States)

    2011-10-11

    Targeted radiotherapy is an evolving and promising modality of cancer treatment. The killing of cancer cells is achieved with the use of biological vectors and appropriate radionuclides. Among the many advantages of this approach are its selectiveness in delivering the radiation to the target, relatively less severe and infrequent side effects, and the possibility of assessing the uptake by the tumor prior to the therapy. Several different radiopharmaceuticals are currently being used by various administration routes and targeting mechanisms. This article aims to briefly review the current status of targeted radiotherapy as well as to outline the advantages and disadvantages of radionuclides used for this purpose.

  8. Radionuclide deposition control

    International Nuclear Information System (INIS)

    1980-01-01

    A method is described for controlling the deposition, on to the surfaces of reactor components, of the radionuclides manganese-54, cobalt-58 and cobalt-60 from a liquid stream containing the radionuclides. The method consists of disposing a getter material (nickel) in the liquid stream, and a non-getter material (tantalum, tungsten or molybdenum) as a coating on the surfaces where deposition is not desired. The process is described with special reference to its use in the coolant circuit in sodium cooled fast breeder reactors. (U.K.)

  9. Radionuclide examination in rheumatology

    International Nuclear Information System (INIS)

    Streda, A.; Kolar, J.; Valesova, M.

    1984-01-01

    On the basis of twenty years of experience with the use of radionuclides in bone and articular rheumatic diseases indications for such examinations are summed up. The main advantage of the use of radionuclide methods is that they bring forward early diagnosis of tissue reconstruction which can thus be detected at the stage of microstructural changes. They also provide earlier and more reliable detection of the degree of the pathological process than is provided by X-ray examination. In some cases scintiscan may also be found useful as a method for following up the results of treatment of rheumatic diseases. (author)

  10. Targeted Radionuclide Therapy

    International Nuclear Information System (INIS)

    Ersahin, Devrim; Doddamane, Indukala; Cheng, David

    2011-01-01

    Targeted radiotherapy is an evolving and promising modality of cancer treatment. The killing of cancer cells is achieved with the use of biological vectors and appropriate radionuclides. Among the many advantages of this approach are its selectiveness in delivering the radiation to the target, relatively less severe and infrequent side effects, and the possibility of assessing the uptake by the tumor prior to the therapy. Several different radiopharmaceuticals are currently being used by various administration routes and targeting mechanisms. This article aims to briefly review the current status of targeted radiotherapy as well as to outline the advantages and disadvantages of radionuclides used for this purpose

  11. Aortic insufficiency and hydralazine: behaviour of left ventricular ejection fraction and of stroke index ratio at rest and during exercise

    International Nuclear Information System (INIS)

    Sole, C.; Florenzano, F.; Morales, B.; Neubauer, S.; Escobar, E.; Mollerach, F.; Mollerach, A.; Avella, O.

    1982-01-01

    The gated blood pool ventriculography in patients undergoing in vivo red blood cells labelling with 99mTc-pertechnetate, was evaluated critically as a form of quantifying aortic valvular regurgitation (AVR) and was applicated in severe aortic insufficiency (AI) to determine the effects of Hydralazine at rest and during exercise on the ventricular function parameters thus obtained. The beneficious effects of Hydralazine on left ventricular performance in patients with AI, have already been reported. The results confirm this too, but using a non-invasive method. These beneficious effects of Hydralazine in patients with AI were proved to be a consequence of significant increase in left ventricular ejection fraction (LVEF)

  12. Taking radionuclides to heart

    International Nuclear Information System (INIS)

    Kleynhans, P.H.T.; Lotter, M.G.; Van Aswegen, A.; Minnaar, P.C.; Iturralde, M.; Herbst, C.P.; Marx, D.

    1980-01-01

    Ischaemic heart disease is a main cause of death in South Africa. Non-invasive ECG gated radionuclide bloodpool imaging plays an increasingly useful role in the evalution of the function of the heart as a pump, and the extent of heart muscle perfusion defects is further pinpointed by invasive krypton-81m studies to improve patient management

  13. Radionuclides deposition over Antarctica

    International Nuclear Information System (INIS)

    Pourchet, M.; Magand, O.; Frezzotti, M.; Ekaykin, A.; Winther, J.-G.

    2003-01-01

    A detailed and comprehensive map of the distribution patterns for both natural and artificial radionuclides over Antarctica has been established. This work integrates the results of several decades of international programs focusing on the analysis of natural and artificial radionuclides in snow and ice cores from this polar region. The mean value (37±20 Bq m -2 ) of 241 Pu total deposition over 28 stations is determined from the gamma emissions of its daughter 241 Am, presenting a long half-life (432.7 yrs). Detailed profiles and distributions of 241 Pu in ice cores make it possible to clearly distinguish between the atmospheric thermonuclear tests of the fifties and sixties. Strong relationships are also found between radionuclide data ( 137 Cs with respect to 241 Pu and 210 Pb with respect to 137 Cs), make it possible to estimate the total deposition or natural fluxes of these radionuclides. Total deposition of 137 Cs over Antarctica is estimated at 760 TBq, based on results from the 90-180 deg. East sector. Given the irregular distribution of sampling sites, more ice cores and snow samples must be analyzed in other sectors of Antarctica to check the validity of this figure

  14. Soil burden by radionuclides

    International Nuclear Information System (INIS)

    Blum, W.E.H.; Wenzel, W.W.

    1989-01-01

    Natural radioactivity - half-lifes and radiation type of man-made nuclides, radionuclide behaviour in soils, effects on soil condition and soil functions are described. The only mode of decontamination is by decay and thus primarily dependent on the half-life of nuclides

  15. Radionuclides in house dust

    Energy Technology Data Exchange (ETDEWEB)

    Fry, F A; Green, N; Dodd, N J; Hammond, D J

    1985-04-01

    Discharges of radionuclides from the British Nuclear Fuel plc (BNFL) reprocessing plant at Sellafield in Cumbria have led to elevated concentrations radionuclides in the local environment. The major routes of exposure of the public are kept under review by the appropriate authorising Government departments and monitoring is carried out both by the departments and by BNFL itself. Recently, there has been increasing public concern about general environmental contamination resulting from the discharges and, in particular, about possible exposure of members of the public by routes not previously investigated in detail. One such postulated route of exposure that has attracted the interest of the public, the press and Parliament arises from the presence of radionuclides within houses. In view of this obvious and widespread concern, the Board has undertaken a sampling programme in a few communities in Cumbria to assess the radiological significance of this source of exposure. From the results of our study, we conclude that, although radionuclides originating rom the BNFL site can be detected in house dust, this source of contamination is a negligible route of exposure for members of the public in West Cumbria. This report presents the results of the Board's study of house dust in twenty homes in Cumbria during the spring and summer of 1984. A more intensive investigation is being carried out by Imperial College. (author)

  16. Radionuclide body function imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1983-01-01

    A transverse radionuclide scan field imaging apparatus is claimed. It comprises: a plurality of highly focused closely laterally adjacent collimators arranged inwardly focused in an array which surrounds a scan field, each collimator being moveable relative to its adjacent collimator; means for rotating the array about the scan field and means for imparting travel to the collimators

  17. Intercomparison of radionuclide measurements in marine sediment sample IAEA-367

    International Nuclear Information System (INIS)

    Ballestra, S.; Lopez, J.J.; Gastaud, J.; Vas, D.; Noshkin, V.

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-367, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 81 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for 60 Co, 90 Sr, 137 Cs, 239+240 Pu (Reference date: 1 January 1990). Information values for 155 Eu, 238 Pu, 241 Am, and 241 Pu are reported. Information values for the following natural radionuclides 40 K, 226 Ra, 228 Th, 230 Th, 234 U, 235 U and 238 U are also reported. (author)

  18. Predictors of sudden death and death from pump failure in congestive heart failure are different. Analysis of 24 h Holter monitoring, clinical variables, blood chemistry, exercise test and radionuclide angiography

    DEFF Research Database (Denmark)

    Madsen, B K; Rasmussen, Verner; Hansen, J F

    1997-01-01

    Association class II and 44% in III. Total mortality after 1 year was 21%, after 2 years 32%. Of 60 deaths, 33% were sudden and 49% due to pump failure. Multivariate analyses identified totally different risk factors for sudden death: ventricular tachycardia, s-sodium ....6 mmol/l, s-potassium sudden death and for death from progressive pump failure........80 mmol/l, s-creatinine > 121 mumol/l, and maximal change in heart rate during exercise death from progressive pump failure: New York Heart Association class III + IV, delta heart rate over 24 h 7...

  19. Radionuclides in food

    International Nuclear Information System (INIS)

    Fernandez Gomez, Isis Maria

    2008-01-01

    The sources of the presence of radionuclides in food are presented: natural radiation and artificial radiation. The transfer of radionuclides through food chains, intakes of radionuclides to the body with its partners effective doses and typical consumption of basic foods of a rural adult population are exposed as main topics. Also the radiation doses from natural sources and exposure to man by ingestion of contaminated food with radionuclides of artificial origin are shown. The contribution of the food ingestion to the man exposure depends on: characteristics of radionuclide, natural conditions, farming practices and eating habits of the population. The principal international organizations in charge of setting guide levels for radionuclides in food are mentioned: standards, rules and the monitoring. It establishes that a guide is necessary for the food monitoring; the alone CODEX ALIMENTARIUS is applicable to emergency situations and the generic action levels proposed by the CODEX not satisfy all needs (no guiding international levels for planned or existing situations such as NORM). There are handled mainly socio-economic and political aspects. Among the actions to be taken are: to assure a public comprehensive information over the risk evaluation in food; to reinforce the collaboration among the different international organizations (WHO, IAEA, ICRP, EC) in relation with the food of set; to give follow-up to the control of the drinkable water and NORM's presence in the food. In addition, it is possible to create the necessary mechanisms to reduce the number of irrelevant measures and bureaucratic useless steps (certificates); to promote the exchange between the different institutions involved in the topic of the food, with relation to the acquired experiences and learned lessons. Likewise, it might examine the possibility of a multidisciplinary approximation (radioactive and not radioactive pollutants); to elaborate a technical guide to assure the

  20. EBS Radionuclide Transport Abstraction

    International Nuclear Information System (INIS)

    J. Prouty

    2006-01-01

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment (TSPA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport model considers advective transport and diffusive transport

  1. EBS Radionuclide Transport Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    J. Prouty

    2006-07-14

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment (TSPA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport model considers advective transport and diffusive transport

  2. EBS Radionuclide Transport Abstraction

    International Nuclear Information System (INIS)

    Schreiner, R.

    2001-01-01

    The purpose of this work is to develop the Engineered Barrier System (EBS) radionuclide transport abstraction model, as directed by a written development plan (CRWMS M and O 1999a). This abstraction is the conceptual model that will be used to determine the rate of release of radionuclides from the EBS to the unsaturated zone (UZ) in the total system performance assessment-license application (TSPA-LA). In particular, this model will be used to quantify the time-dependent radionuclide releases from a failed waste package (WP) and their subsequent transport through the EBS to the emplacement drift wall/UZ interface. The development of this conceptual model will allow Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department to provide a more detailed and complete EBS flow and transport abstraction. The results from this conceptual model will allow PA0 to address portions of the key technical issues (KTIs) presented in three NRC Issue Resolution Status Reports (IRSRs): (1) the Evolution of the Near-Field Environment (ENFE), Revision 2 (NRC 1999a), (2) the Container Life and Source Term (CLST), Revision 2 (NRC 1999b), and (3) the Thermal Effects on Flow (TEF), Revision 1 (NRC 1998). The conceptual model for flow and transport in the EBS will be referred to as the ''EBS RT Abstraction'' in this analysis/modeling report (AMR). The scope of this abstraction and report is limited to flow and transport processes. More specifically, this AMR does not discuss elements of the TSPA-SR and TSPA-LA that relate to the EBS but are discussed in other AMRs. These elements include corrosion processes, radionuclide solubility limits, waste form dissolution rates and concentrations of colloidal particles that are generally represented as boundary conditions or input parameters for the EBS RT Abstraction. In effect, this AMR provides the algorithms for transporting radionuclides using the flow geometry and radionuclide concentrations determined by other

  3. Initial Radionuclide Inventories

    Energy Technology Data Exchange (ETDEWEB)

    H. Miller

    2004-09-19

    The purpose of this analysis is to provide an initial radionuclide inventory (in grams per waste package) and associated uncertainty distributions for use in the Total System Performance Assessment for the License Application (TSPA-LA) in support of the license application for the repository at Yucca Mountain, Nevada. This document is intended for use in postclosure analysis only. Bounding waste stream information and data were collected that capture probable limits. For commercially generated waste, this analysis considers alternative waste stream projections to bound the characteristics of wastes likely to be encountered using arrival scenarios that potentially impact the commercial spent nuclear fuel (CSNF) waste stream. For TSPA-LA, this radionuclide inventory analysis considers U.S. Department of Energy (DOE) high-level radioactive waste (DHLW) glass and two types of spent nuclear fuel (SNF): CSNF and DOE-owned (DSNF). These wastes are placed in two groups of waste packages: the CSNF waste package and the codisposal waste package (CDSP), which are designated to contain DHLW glass and DSNF, or DHLW glass only. The radionuclide inventory for naval SNF is provided separately in the classified ''Naval Nuclear Propulsion Program Technical Support Document'' for the License Application. As noted previously, the radionuclide inventory data presented here is intended only for TSPA-LA postclosure calculations. It is not applicable to preclosure safety calculations. Safe storage, transportation, and ultimate disposal of these wastes require safety analyses to support the design and licensing of repository equipment and facilities. These analyses will require radionuclide inventories to represent the radioactive source term that must be accommodated during handling, storage and disposition of these wastes. This analysis uses the best available information to identify the radionuclide inventory that is expected at the last year of last emplacement

  4. Application of radionuclide techniques in evaluation of dilated cardiomyopathy and ischemic cardiomyopathy

    International Nuclear Information System (INIS)

    Tian Yueqin; Liu Xiujie; Shi Rongfang

    2000-01-01

    Objective: To assess the clinical significance of radionuclide techniques in differentiating dilated cardiomyopathy (DCM) from ischemic cardiomyopathy (CAD-CM). Methods: 28 patients (pts) with DCM and 55 pts with CAD-CM were studied. All pts underwent 99 Tc m -MIBI myocardial perfusion SPECT and 18 F-FDG myocardial metabolic PET. 73 pts had 99 Tc m -RBC radionuclide ventriculography and 68 pts had coronary angiography. Results: 23 pts (82%) with DCM showed perfusion abnormalities with mild and not segmental distribution. 52 pts (95%) with CAD-CM showed perfusion abnormalities that distributed along the coronary vessel territories. Perfusion defects were found in 4 pts (14%) with DCM and 45 pts (82%) with CAD-CM (P<0.01). The average perfusion score was 4.5 +- 2.6 in DCM and 9.5 +- 2.9 in CAD-CM, the area of perfusion diminished uptake was significantly smaller in DCM than in CAD-CM (P < 0.001). 2 pts with DCM and 18 pts with CAD-CM had metabolic defect. The patterns of perfusion/metabolic imaging showed mismatch in most pts with CAD-CM but match in pts with DCM. The LVEF in pts with DCM and CAD-CM was decreased but no significant difference between DCM and CAD-CM was observed. The RVEF in pts with DCM was significantly lower than that in pts with CAD-CM (32.4% +- 13.9% vs 40.9% +- 15.4%, P < 0.05). Conclusions: The radionuclide techniques showed to be helpful for distinguishing DCM from CAD-CM. The discriminate analysis revealed that segmental perfusion abnormality and RVEF were the most important factors for differentiation of DCM from CAD-CM

  5. Clinical evaluation of segmental wall motion by radionuclide cardioangiography in the patients with myocardial infarction

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Kozuka, Takahiro

    1980-01-01

    To detect segmental wall motion of left ventricle is useful to identify the size and location of infarcted area in coronary arteries diseases. In this study, segmental wall motion by radionuclide cardioangiography were evaluated to compare with contrast left ventriculography in fifty patients of myocardial infarction. Segmental wall motion in RAO position by first pass method, in LAO position by multi-gated method were evaluated using an Anger camera and on-line minicomputer system by following methods; ED, ES images, sequential images, edge display, regional ejection fraction and movie imaging system (MIS). The percent agreements of segmental wall motion by RI and LVG were 84% in 350 segments of 50 cases. In all segments, segments 4, 6, 7 were better agreements than other segments. For the degree of wall motion, skinesis and dyskinesis were good agreements in both methods, while hypokinesia was slightly poor agreement (62%). On the other hand, the size of infarction, that is, percent thallium defect area was good correlated with radionuclide left ventricular ejection fraction (r = -0.855 in anterior infarction, r = -0.646 in inferior infarction). From these data, wall motion was thought to be closely related with left ventricular function, therefore, regional ejection fraction in seven areas in left ventricular image was developed and compared with segmental wall motion in left ventriculogram according to the classification of A.H.A. Comittee Report. The value of regional ejection fraction is 0.29, 0.40, 0.60 in akinesis, hypokinesis and normal. In conclusion, radionuclide cardioangiography is useful in the detection of abnormal segmental wall motion as noninvasive methods. (author)

  6. An intercomparison on radionuclides in environmental samples, Baltic-Danish co-operation project on radiation protection 2001-2003

    DEFF Research Database (Denmark)

    Nielsen, S.P.

    2004-01-01

    Sixteen laboratories participated in an intercomparison exercise carried out in 2003 on laboratory analyses of radionuclides in environmental samples. The sample types included seawater, lake water, soil, dry milk and seaweed and the exercise involved theradionuclides 137Cs, 90Sr, 60Co, 239, 240Pu...... laboratories passed the evaluation tests. The results indicate that for several of the laboratories there isroom to improve the analytical quality on radionuclides in environmental samples to match an uncertainty corresponding to a relative standard deviation of 10%....

  7. Fukushima Daiichi Radionuclide Inventories

    Energy Technology Data Exchange (ETDEWEB)

    Cardoni, Jeffrey N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jankovsky, Zachary Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-01

    Radionuclide inventories are generated to permit detailed analyses of the Fukushima Daiichi meltdowns. This is necessary information for severe accident calculations, dose calculations, and source term and consequence analyses. Inventories are calculated using SCALE6 and compared to values predicted by international researchers supporting the OECD/NEA's Benchmark Study on the Accident at Fukushima Daiichi Nuclear Power Station (BSAF). Both sets of inventory information are acceptable for best-estimate analyses of the Fukushima reactors. Consistent nuclear information for severe accident codes, including radionuclide class masses and core decay powers, are also derived from the SCALE6 analyses. Key nuclide activity ratios are calculated as functions of burnup and nuclear data in order to explore the utility for nuclear forensics and support future decommissioning efforts.

  8. Radionuclide table. Pt. 1

    International Nuclear Information System (INIS)

    Legrand, Jean; Perolat, J.-P.; Lagoutine, Frederic; Le Gallic, Yves.

    The evaluation of the following 29 radionuclides is presented: 22 Na, 24 Na, sup(24m)Na, 51 Cr, 54 Mn, 57 Co, 58 Co, sup(58m)Co, 60 Co, sup(60m)Co, 75 Se, 103 Ru, sup(103m)Rh, sup(110m)Ag- 110 Ag, 109 Cd, 125 Sb, sup(125mTe), 125 I, 133 Xe, sup(133m)Xe, 131 Cs, 134 Cs, sup(134m)Cs, 139 Ce, 144 Ce- 144 Pr, 144 Pr, 169 Er, 186 Re, 203 Hg. The introduction contains a brief description of radioactive processes and the evaluation rules followed. The best values and associated uncertainties are given for each radionuclide for the major parameters of the decay scheme and the radiation intensities emitted, together with a decay table. Gamma, X-rays and sometimes conversion electron spectra are also provided [fr

  9. Radionuclide co-precipitation

    International Nuclear Information System (INIS)

    Bruno, J.; Sandino, A.

    1987-12-01

    The thermodynamic and kinetic behaviour of the minor components of the spent fuel matrix has been theoretically and experimentally investigated. Two different situations have been studied: Part I, the near field scenario, where the release and migration of the minor components is dependent on the solubility behaviour of UO 2 (s); Part II, the far field, where the solubility and transport of the radionuclides is related to the major geochemical processes occurring. (orig.)

  10. Radionuclide fate and effects

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The studies reported here deal with the full range of contaminant behavior and fate, from the initial physicochemical factors that govern radionuclide availability in terrestrial and aquatic environments to studies of contaminant transport by biological means. By design, we focus more on the biologically and chemically mediated transport processes and food-chain pathways than on the purely physical forms of contaminant transport, such as transport by wind and water

  11. Geochemistry and radionuclide migration

    International Nuclear Information System (INIS)

    Isherwood, D.

    1978-01-01

    Theoretically, the geochemical barrier can provide a major line of defense in protecting the biosphere from the hazards of nuclear waste. The most likely processes involved are easily identified. Preliminary investigations using computer modeling techniques suggest that retardation is an effective control on radionuclide concentrations. Ion exchange reactions slow radionuclide migration and allow more time for radioactive decay and dispersion. For some radionuclides, solubility alone may limit concentrations to less than the maximum permissible now considered acceptable by the Federal Government. The effectiveness of the geochemical barrier is ultimately related to the repository site characteristics. Theory alone tells us that geochemical controls will be most efficient in an environment that provides for maximum ion exchange and the precipitation of insoluble compounds. In site selection, consideration should be given to rock barriers with high ion exchange capacity that might also act as semi-permeable membranes. Also important in evaluating the site's potential for effective geochemical controls are the oxidation potentials, pH and salinity of the groundwater

  12. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Howard, B.J.; Kennedy, V.H.; Nelson, A.

    1983-06-01

    A bibliographical database has been developed to provide quick access to research and background literature in the field of radioecology. This is a development of an earlier database described by Nelson (Bocock 1981). ITE's particular fields of interest have led to a subject bias in the bibliography towards studies in Cumbria, especially those concerned with radionuclides originating from the reprocessing plant at Sellafield, and towards ecological research studies that are complementary to radionuclide studies. Other subjects covered, include the chemistry of radionuclides, budgets and transfers within ecosystems and techniques for the analysis of environmental samples. ITE's research objectives have led to the establishment of a specialized database which is intended to complement rather than compete with the large international databases made available by suppliers such as IRS-DIALTECH or DIALOG. Currently the database holds about 1900 references which are stored on a 2 1/2 megabyte hard disk on a Digital PDP11/34 computer operating under a time shared system. The references follow a standard format. (author)

  13. Radionuclides in marine organisms

    International Nuclear Information System (INIS)

    Honda, Teruyuki

    2001-01-01

    The concentration and accumulation of radionuclides in marine organisms were explained in this paper. Secular change of the radioactivity concentration of 137 Cs in seaweed in coastal area of Japan showed more than 5Bq/kg-fresh in the first half of 1960, but decreased less than 1 Bq/kg-fresh after then and attained to less than 0.1 Bq/kg-fresh in 1990s. However, the value increased a while in 1986, which indicated the effect of Chernobyl accident. The accident increased 137 Cs of shellfish near Japan. The concentration of 239+240 Pu was the lowest value in muscles of fish, but increased from 1.7 to 42.3 mBq/kg wet wt in seaweed in 1999. 99 Tc concentration of seaweed showed from 100 to 1000 times as much as that of seawater. Radionuclides in the Irish Sea are originated from Sellafield reprocessing plant. The concentration factors of macro-algae and surface water fish (IAEA,1985) were shown. Analytical results of U in 61 kinds of marine organs showed that the concentration was different in the part of organ. The higher concentration of U was observed in hard tissue of fish. The concentration factor was different between chemical substances with the same radionuclides. (S.Y.)

  14. Radionuclides in thyroid cancer

    International Nuclear Information System (INIS)

    Mahadev, V.

    1980-01-01

    The three main areas of application of radionuclides in thyroid disease will be reviewed. Firstly thyroid radionuclide imaging in thyroid swellings, in relationship to lumps in the neck and ectopic thyroid tissue such as retrosternal goitre, and lingual goitre will be described. Future developments in the field including tomographic scanning, using the coded aperture method, and fluorescent scans and ultrasound are reviewed. The second area of application is the assessment and evaluation of thyroid function and the therapy of Grave's Disease and Plummer's Disease using radioiodine. The importance of careful collection of the line of treatment, results of treatment locally and the follow-up of patients after radioiodine therapy will be described. The third area of application is in the diagnosis and therapy of thyroid cancer. Investigation of thyroid swelling, and the diagnosis of functioning metastases are reported. The therapeutic iodine scan as the sole evidence of functioning metastatic involvement is recorded. Histological thyroid cancer appears to be increasingly encountered in clinical practice and the plan of management in relation to choice of cases for therapeutic scanning is discussed with case reports. Lastly the role of whole body scanning in relationship to biochemical markers is compared. In the changing field of nuclear medicine radionuclide applications in thyroid disease have remained pre-eminent and this is an attempt to reassess its role in the light of newer developments and local experience in the Institute of Radiotherapy, Oncology and Nuclear Medicine. (author)

  15. Right heart ventriculography

    Science.gov (United States)

    Angiography - right heart ... moved forward into the right side of the heart. As the catheter is advanced, the doctor can ... is injected into the right side of the heart. It helps the cardiologist determine the size and ...

  16. Prevention: Exercise

    Medline Plus

    Full Text Available ... A SPECIALIST Prevention Strengthening Exercise Committee Exercise Committee Core Strengthening Many popular forms of exercise focus on ... acute pain, you should stop doing it. Transverse Core Strengthening This strengthens the muscles that cross from ...

  17. Prevention: Exercise

    Medline Plus

    Full Text Available ... Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! Stretching/Flexibility Aerobic Exercise Cervical Exercise Strength Training for the Elderly Other Back Pack Safety Pregnancy ...

  18. Report on the intercomparison run IAEA-308 radionuclides in seaweed mixture

    International Nuclear Information System (INIS)

    Ballestra, S.; Vas, D.; Lopez, J.J.; Noshkin, V.

    1989-12-01

    The results of an intercomparison exercise on a sample of mixed seaweeds from the Mediterranean Sea, IAEA-308, designed for the determination of artificial and natural radionuclide levels, are reported. The data from 67 laboratories representing 33 countries have been evaluated. The recommended median values, with confidence intervals, for the most frequently measured radionuclides 106 Ru, 110m Ag, 134 Cs, 137 Cs, 238 Pu, 239+240 Pu, 241 Am, 40 K, 210 Pb and 228 Th are given. Refs and tabs

  19. Application and validation of predictive computer programs describing the chemistry of radionuclides in the geosphere

    International Nuclear Information System (INIS)

    Waters, M.; Duffield, J.R.; Griffiths, P.J.F.; Williams, D.R.

    1991-01-01

    Chemval is an international project concerned with improving the data used to model the speciation chemistry of radionuclide migration from underground waste disposal sites. Chemval has two main aims: to produce a reliable database of thermodynamic equilibrium constants for use in such chemical modelling; to perform a series of test-case modelling exercises based upon real site and field data to verify and validate the existing tools used for simulating the chemical speciation and the transport of radionuclides in the environment

  20. Chapter 2. Radionuclides in the biosphere

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with role of radionuclides in the biosphere. Chapter consists of next parts: (1) Natural radionuclides in biosphere; (2) Man-made radionuclides in the biosphere; (3) Ecologically important radionuclides; (4) Natural background; (5) Radiotoxicity and (6) Paths of transfer of radionuclides from the source to human

  1. Radionuclide diagnosis of emergency states

    International Nuclear Information System (INIS)

    Ishmukhametov, A.I.

    1985-01-01

    Solution of emergency state radionuclide diagnostics from the technical point of view is provided by the application of the mobile quick-operating equipment in combination with computers, by the use of radionuclides with acceptable for emergency medicine characteristics and by development of radionuclide investigation data propcessing express-method. Medical developments include the study of acute disease and injury radioisotope semiotics, different indication diagnostic value determining, comparison of the results, obtained during radionuclide investigation, with clinicolaboratory and instrumental data, separation of methodical complex series

  2. History of medical radionuclide production.

    Science.gov (United States)

    Ice, R D

    1995-11-01

    Radionuclide production for medical use originally was incidental to isotope discoveries by physicists and chemists. Once the available radionuclides were identified they were evaluated for potential medical use. Hevesy first used 32P in 1935 to study phosphorous metabolism in rats. Since that time, the development of cyclotrons, linear accelerators, and nuclear reactors have produced hundreds of radionuclides for potential medical use. The history of medical radionuclide production represents an evolutionary, interdisciplinary development of applied nuclear technology. Today the technology is represented by a mature industry and provides medical benefits to millions of patients annually.

  3. EBS Radionuclide Transport Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    J.D. Schreiber

    2005-08-25

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in ''Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration'' (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment for the license application (TSPA-LA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA-LA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport

  4. EBS Radionuclide Transport Abstraction

    International Nuclear Information System (INIS)

    J.D. Schreiber

    2005-01-01

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in ''Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration'' (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment for the license application (TSPA-LA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA-LA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport model considers

  5. Osteopetrosis: Radiological & Radionuclide Imaging

    International Nuclear Information System (INIS)

    Sit, Cherry; Agrawal, Kanhaiyalal; Fogelman, Ignac; Gnanasegaran, Gopinath

    2015-01-01

    Osteopetrosis is a rare inherited bone disease where bones harden and become abnormally dense. While the diagnosis is clinical, it also greatly relies on appearance of the skeleton radiographically. X-ray, radionuclide bone scintigraphy and magnetic resonance imaging have been reported to identify characteristics of osteopetrosis. We present an interesting case of a 59-year-old man with a history of bilateral hip fractures. He underwent 99m Tc-methylene diphosphonate whole body scan supplemented with single-photon emission computed tomography/computed tomography of spine, which showed increased uptake in the humeri, tibiae and femora, which were in keeping with osteopetrosis

  6. Modifying radionuclide effects

    International Nuclear Information System (INIS)

    Sasser, L.B.

    1983-01-01

    This project involves a study of the relationship of physiological and environmental factors to the metabolism and effects of radionuclides. We have studied placental transfer and suckling as pathways of americium entry into the newborn or juvenile rat. Rats were injected intravenously with 5 μCi of 241 Am while nulliparous (30 days prior to mating), pregnant (day 19 of gestation), or lactating (1 day after parturition), and subsequent litters were killed to determine 241 Am retention. A deficit in reproductive performance was observed in the group injected before mating, as evidenced by reduced number and weight of offspring

  7. Radionuclides in the sea

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1971-07-01

    Water covers a little more than two-thirds of the earth's surface. What is thrown into the sea from a ship may be washed up on a shore thousands of miles away; wastes discharged into the seas or into rivers flowing into them can affect marine life and possibly also the health of man. The study, prevention and control of pollution of the seas and oceans by radionuclides introduced as by-products of man's use of nuclear energy is thus of global interest. (author)

  8. Sherlock Holmes for radionuclides

    International Nuclear Information System (INIS)

    Schmitzer, C.

    2002-01-01

    At the end of 2001 ARC Seibersdorf research has taken the management of the first worldwide certified laboratory to control the realization of the international Comprehensive Nuclear Test Ban Treaty (CTBT). Altogether there will be 16 CTBT certified laboratories worldwide; therefore a global network of radionuclides measurements stations and test laboratories as well as seismic, radiation and hydroacustic measurements stations is necessary . In the future air samples will be taken from these stations and analyzed in one of these certified laboratories, when appears the suspicion that an atomic test was carried out. (nevyjel)

  9. Radionuclide solubilities at elevated temperatures. A literature study

    International Nuclear Information System (INIS)

    Carlsson, T.; Vuorinen, U.

    1997-07-01

    This literature study contains experimental data and modelling data collected in order to illustrate how temperature affects radionuclide solubilities under conditions similar to those expected in the vicinity of a planned repository for spent nuclear fuel. The elements considered were Ni, Se, Zr, Tc, Pd, Sn, Ra, Th, Pa, U, Np, Pu and Am. The temperatures of main interest are restricted to the interval between room temperature and 100 deg C. The study showed that the literature on radionuclide solubility at temperatures above room temperature is scarce. Therefore, also work that refers to conditions slightly varying from the expected repository conditions has been considered. A minor modelling exercise was done in this study in order to show the effect of temperature on the solubilities of Ni, Np and U under various conditions. The results from the literature survey and our modelling demonstrate the complexity of groundwater systems and the difficulty in finding simple and general relationships between temperature and radionuclide solubilities. Often an increase in temperature (below 100 deg C) leads to a reduction of the radionuclide solubility or leaves it roughly unchanged. However, examples are also found where the rise in temperature increases the radionuclide solubility by several orders of magnitude. (orig.)

  10. Radionuclide solubilities at elevated temperatures. A literature study

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, T.; Vuorinen, U. [Technical Research Centre of Finland, Espoo (Finland)

    1997-07-01

    This literature study contains experimental data and modelling data collected in order to illustrate how temperature affects radionuclide solubilities under conditions similar to those expected in the vicinity of a planned repository for spent nuclear fuel. The elements considered were Ni, Se, Zr, Tc, Pd, Sn, Ra, Th, Pa, U, Np, Pu and Am. The temperatures of main interest are restricted to the interval between room temperature and 100 deg C. The study showed that the literature on radionuclide solubility at temperatures above room temperature is scarce. Therefore, also work that refers to conditions slightly varying from the expected repository conditions has been considered. A minor modelling exercise was done in this study in order to show the effect of temperature on the solubilities of Ni, Np and U under various conditions. The results from the literature survey and our modelling demonstrate the complexity of groundwater systems and the difficulty in finding simple and general relationships between temperature and radionuclide solubilities. Often an increase in temperature (below 100 deg C) leads to a reduction of the radionuclide solubility or leaves it roughly unchanged. However, examples are also found where the rise in temperature increases the radionuclide solubility by several orders of magnitude. (orig.). 54 refs.

  11. Radionuclide Therapy. Chapter 19

    Energy Technology Data Exchange (ETDEWEB)

    Flux, G.; Du, Yong [Royal Marsden Hospital and Institute of Cancer Research, Surrey (United Kingdom)

    2014-12-15

    Cancer has been treated with radiopharmaceuticals since the 1940s. The radionuclides originally used, including 131I and 32P, are still in use. The role of the physicist in radionuclide therapy encompasses radiation protection, imaging and dosimetry. Radiation protection is of particular importance given the high activities of the unsealed sources that are often administered, and must take into account medical staff, comforters and carers, and, as patients are discharged while still retaining activity, members of the public. Regulations concerning acceptable levels of exposure vary from country to country. If the administered radiopharmaceutical is a γ emitter, then imaging can be performed which may be either qualitative or quantitative. While a regular system of quality control must be in place to prevent misinterpretation of image data, qualitative imaging does not usually rely on the image corrections necessary to determine the absolute levels of activity that are localized in the patient. Accurate quantitative imaging is dependent on these corrections and can permit the distribution of absorbed doses delivered to the patient to be determined with sufficient accuracy to be clinically beneficial.

  12. Intervention procedures for radionuclides

    International Nuclear Information System (INIS)

    Adelstein, S.J.

    1991-01-01

    As in the case of smoking and lung cancer, for large radionuclide releases, an ounce of prevention is worth a pound of cure. On the other hand, we feel compelled to do something sensible after an accident even if the principal benefit of intervention may be to comfort the population at risk. Of course, for populations near the site of an accident, evacuation should be considered, but it is unreasonable to apply this measure to distant populations, e.g., large segments of the European community could not be moved about as we observe the shifting of a radioactive cloud in response to changing winds. If the radionuclides are delivered as particulates, bringing people indoors and employing primitive air filters can temporarily reduce exposures, but these stratagems are not very effective against gaseous or volatile elements. What, then, can be done for populations downwind of a radioactive release whose air, water, and/or food supply are, or are about to become contaminated? 5 refs

  13. Report on the intercomparison run and certified reference material IAEA-381. Radionuclides in Irish sea water

    International Nuclear Information System (INIS)

    Povinec, P.P.; Pham, M.K.; Ballestra, S.

    1999-01-01

    The accurate and precise determinations of radionuclide concentrations in marine samples are important aspects of marine radioactivity assessments and the use of radionuclides in studies of oceanographic processes. To address the problem of data quality, the IAEA Marine Environment Laboratory (MEL) in Monaco has conducted intercomparison exercises on radionuclides in marine samples for many years as part of its contribution to the IAEA's programme of Analytical Quality Control Services (AQCS). For this intercomparison exercise, the Federal Maritime and Hydrographic Agency, Hamburg, Germany (BSH) collected sea water from the Irish Sea in 1993. IAEA-MEL distributed sample aliquots during 1995-1996 for intercomparison of anthropogenic and natural radionuclides. About 80 laboratories world-wide were approached with a questionnaire for participation. Of these, only 43 accepted the invitation because of financial constraints (the participating laboratories were asked to pay transportation expenses). As the sample was collected in the Irish Sea, elevated levels of anthropogenic radionuclides were expected due to discharges from the Sellafield reprocessing plant. Participants were informed that the expected activities for anthropogenic radionuclides would be in the ranges: 90 Sr: 50-500 Bq/kg, 137 Cs: 100-1000 Bq/kg, 239+240 Pu: 1-50Bq/kg, 241 Am: 1-50Bq/kg. This report describes the results obtained from 28 laboratories on anthropogenic and natural radionuclide determinations in sea water

  14. Some parameters of radionuclide kinetics

    International Nuclear Information System (INIS)

    Prokof'ev, O.N.; Smirnov, V.A.; Belen'kij, E.I.

    1978-01-01

    Numerical values of the rates of radionuclide absorption into, and elimination from, bovine organs were determined. Kinetic rate constants of radionuclides such as 89 Sr, 99 Mo, 131 I, 132 Tl, and 140 Be were calculated. The calculations were done for muscle, liver, and kidney

  15. Radionuclide - Soil Organic Matter Interactions

    DEFF Research Database (Denmark)

    Carlsen, Lars

    1985-01-01

    Interactions between soil organic matter, i.e. humic and fulvic acids, and radionuclides of primary interest to shallow land burial of low activity solid waste have been reviewed and to some extent studied experimentally. The radionuclides considered in the present study comprise cesium, strontium...

  16. Chapter 13. Radionuclides in medicine

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with problems connected with using of radionuclides in medicine. Methods of treatment with using of radionuclides are reviewed. Chapter consists of next parts: (1) Remotion of thyroid gland; (2) Treatment of cerebrally tumour in nuclear reactor; (3) Artificial heart

  17. Radionuclide methods of identifying patients who may require coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Beller, G.A.; Gibson, R.S.; Watson, D.D.

    1985-01-01

    Myocardial thallium-201 ( 201 Tl) scintigraphy or radionuclide angiography performed in conjunction with exercise stress testing can provide clinically useful information regarding the functional significance of underlying coronary artery stenoses in patients with known or suspected coronary artery disease. Knowledge of type, location, and extent of myocardial 201 Tl perfusion abnormalities or the severity of exercise-induced global and regional dysfunction has prognostic value. Risk stratification can be undertaken with either radionuclide technique by consideration of the magnitude of the ischemic response and may assist in the selection of patients for coronary artery bypass graft surgery (CABG). In patients with coronary artery disease, delayed 201 Tl redistribution observed on exercise or dipyridamole 201 Tl scintigraphy, particularly when present in multiple vascular regions and associated with increased lung 201 Tl uptake, has been shown to be predictive of an adverse outcome, whereas patients with chest pain and a normal exercise 201 Tl scintigram have a good prognosis with medical treatment. Similarly, a marked fall in the radionuclide ejection fraction from rest to exercise has been found to correlate with high-risk anatomic disease. Another important application of radionuclide imaging in patients being considered for CABG (particularly those with a depressed resting left ventricular ejection fraction) is the determination of myocardial viability and potential for improved blood flow and enhanced regional function after revascularization. 69 references

  18. Radionuclide transverse section imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1980-01-01

    A radioisotope scanning apparatus for use in nuclear medicine is described in detail. The apparatus enables the quantification and spatial location of the radioactivity in a body section of a patient to be determined with high sensitivity. It consists of an array of highly focussed collimators arranged such that adjacent collimators move in the same circumferential but opposite radial directions. The explicit movements of the gantry are described in detail and may be controlled by a general purpose computer. The use of highly focussed collimators allows both a reasonable solid angle of acceptance and also high target to background images; additionally, dual radionuclide pharmaceutical studies can be performed simultaneously. It is claimed that the high sensitivity of the system permits the early diagnosis of pathological changes and the images obtained show accurately the location and shape of physiological abnormalities. (UK)

  19. Radioactivity, radionuclides, radiation

    CERN Document Server

    Magill, Joseph

    2005-01-01

    RADIOACTIVITY – RADIONUCLIDES – RADIATION is suitable for a general audience interested in topical environmental and human health radiological issues such as radiation exposure in aircraft, food sterilisation, nuclear medicine, radon gas, radiation dispersion devices ("dirty bombs")… It leads the interested reader through the three Rs of nuclear science, to the forefront of research and developments in the field. The book is also suitable for students and professionals in the related disciplines of nuclear and radiochemistry, health physics, environmental sciences, nuclear and astrophysics. Recent developments in the areas of exotic decay modes (bound beta decay of ‘bare’ or fully ionized nuclei), laser transmutation, nuclear forensics, radiation hormesis and the LNT hypothesis are covered. Atomic mass data for over 3000 nuclides from the most recent (2003) evaluation are included.

  20. Deep sea radionuclides

    International Nuclear Information System (INIS)

    Kanisch, G.; Vobach, M.

    1993-01-01

    Every year since 1979, either in sping or in summer, the fishing research vessel 'Walther Herwig' goes to the North Atlantic disposal areas of solid radioactive wastes, and, for comparative purposes, to other areas, in order to collect water samples, plankton and nekton, and, from the deep sea bed, sediment samples and benthos organisms. In addition to data on the radionuclide contents of various media, information about the plankton, nekton and benthos organisms living in those areas and about their biomasses could be gathered. The investigations are aimed at acquiring scientifically founded knowledge of the uptake of radioactive substances by microorganisms, and their migration from the sea bottom to the areas used by man. (orig.) [de

  1. Radionuclide reporter gene imaging

    International Nuclear Information System (INIS)

    Min, Jung Joon

    2004-01-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases

  2. Radionuclide reporter gene imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Joon [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of)

    2004-04-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases.

  3. Natural radionuclides in groundwaters

    International Nuclear Information System (INIS)

    Laul, J.C.

    1990-01-01

    The U-234 and Th-230 radionuclides are highly retarded by factors of 10 4 to 10 5 in basalt groundwater (Hanford) and briny groundwaters from Texas and geothermal brine from the Salton Sea Geothermal Field (SSGF). In basalt groundwaters (low ionic strength), Ra is highly sorbed, while in brines (high ionic strength), Ra is soluble. This is probably because the sorption sites are saturated with Na + and Cl - ions and RaCl 2 is soluble in brines. Pb-210 is soluble in SSGF brine, probably as a chloride complex. The U-234/Th-230 ratios in basalt groundwaters and brines from Texas and SSGF are nearly unity, indicating that U is in the +4 state, suggesting a reducing environment for these aquifers. 19 refs., 3 figs

  4. Natural radionuclides in groundwaters

    International Nuclear Information System (INIS)

    Laul, J.C.

    1992-01-01

    The 234 U and 230 Th radionuclides are highly retarded by factors of 10 4 to 10 5 in basalt groundwater (Hanford) and briny groundwaters from Texas, and geothermal brine form the Salton Sea Geothermal Field (SSGF). In basalt groundwaters (low ionic strength), Ra is highly sorbed, while in brines (high ionic strength), Ra is soluble. This is probably because the sorption sites are saturated with Na + and Cl - ions, and RaCl 2 is soluble in brines. 210 Pb is soluble in SSGF brine, probably as a chloride complex. The 234 U/ 230 Th ratios in basalt groundwaters and brines from Texas and SSGF are nearly unity, indicating that U is in the +4 state, suggesting a reducing environment for these aquifers. (author) 19 refs.; 3 figs

  5. Significant Radionuclides Determination

    Energy Technology Data Exchange (ETDEWEB)

    Jo A. Ziegler

    2001-07-31

    The purpose of this calculation is to identify radionuclides that are significant to offsite doses from potential preclosure events for spent nuclear fuel (SNF) and high-level radioactive waste expected to be received at the potential Monitored Geologic Repository (MGR). In this calculation, high-level radioactive waste is included in references to DOE SNF. A previous document, ''DOE SNF DBE Offsite Dose Calculations'' (CRWMS M&O 1999b), calculated the source terms and offsite doses for Department of Energy (DOE) and Naval SNF for use in design basis event analyses. This calculation reproduces only DOE SNF work (i.e., no naval SNF work is included in this calculation) created in ''DOE SNF DBE Offsite Dose Calculations'' and expands the calculation to include DOE SNF expected to produce a high dose consequence (even though the quantity of the SNF is expected to be small) and SNF owned by commercial nuclear power producers. The calculation does not address any specific off-normal/DBE event scenarios for receiving, handling, or packaging of SNF. The results of this calculation are developed for comparative analysis to establish the important radionuclides and do not represent the final source terms to be used for license application. This calculation will be used as input to preclosure safety analyses and is performed in accordance with procedure AP-3.12Q, ''Calculations'', and is subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (DOE 2000) as determined by the activity evaluation contained in ''Technical Work Plan for: Preclosure Safety Analysis, TWP-MGR-SE-000010'' (CRWMS M&O 2000b) in accordance with procedure AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering, and Regulatory Compliance Activities''.

  6. Radionuclide calibrators performance evaluation

    International Nuclear Information System (INIS)

    Mora Ramirez, E.; Zeledon Fonseca, P.; Jimenez Cordero, M.

    2008-01-01

    Radionuclide calibrators are used to estimate accurately activity prior to administration to a patient, so it is very important that this equipment meets its performance requirements. The purpose of this paper is to compare the commercially available 'Calicheck' (Calcorp. Inc), used to assess linearity, versus the well-known source decay method, and also to show our results after performing several recommended quality control tests. The parameters that we wanted to evaluate were carried on using the Capintec CRC-15R and CRC-15 β radionuclide calibrators. The evaluated tests were: high voltage, display, zero adjust, background, reproducibility, source constancy, accuracy, precision and linearity. The first six tests were evaluated on the daily practice, here we analyzed the 2007 recorded data; and the last three were evaluated once a year. During the daily evaluation both calibrators performance were satisfactory comparing with the manufacture's requirements. The accuracy test show result within the ± 10% allowed for a field instrument. Precision performance is within the ± 1 % allowed. On the other hand, the linearity test shows that using the source decay method the relative coefficient is 0.9998, for both equipment and using the Calicheck the relative coefficient is 0.997. However, looking the percentage of error, during the 'Calicheck' test, its range goes from 0.0 % up to -25.35%, and using the source decay method, the range goes from 0.0 % up to -31.05 %, taking into account both instruments. Checking the 'Calicheck' results we can see that the results varying randomly, but using the source decay method the percentage of error increase as the source activity decrease. We conclude that both devices meet its manufactures requirements, in the case of the linearity using the decay method, decreasing the activity source, increasing the percentage of error, this may happen because of the equipment age. (author)

  7. Preliminary study of left ventricular cavity-to-myocardial count ratio. A new parameter for left ventricular function

    International Nuclear Information System (INIS)

    Zhou Ying; Qu Wanying; Zhu Ming; Gao Wenping; Zhao Hongshan

    1995-01-01

    A new simple quantitative parameter, left ventricular cavity-to-myocardial count ratio (C/M ratio) was suggested and compared with LVEF to assess its reliability and clinical value. Of 220 patients in the study, 102 had both exercise 99m Tc-MIBI myocardial SPECT imaging and resting radionuclide ventriculography, another 118 patients had both rest 99m Tc-MIBI myocardial SPECT imaging and rest radionuclide ventriculography, 740 MBq of 99m Tc-MIBI was injected intravenously. Both the exercise and rest C/M ratio were determined on short-axis tomograms and LVEF were calculated from radionuclide ventriculography. The correlation between LVEF and the C/M (exercise and rest) was analyzed. There was a positive linear correlation between LVEF measured by ventriculography and both C/M exercise ratio (r = 0.6964) and C/M rest ratio (r = 0.6995). The sensitivity of C/M exercise and rest ratio for detecting patients with left ventricular dysfunction is 71.9%, 68.6%; the specificity is 92.9%, 97.0%; the accuracy is 86.3%, 84.7% respectively. C/M ratio can accurately identify patients with CAD who have resting left ventricular dysfunction. It was highly reproducible, reliable and useful in clinical diagnosis

  8. Geomorphological applications of environmental radionuclides

    International Nuclear Information System (INIS)

    Quine, T.A.; Walling, D.

    1998-01-01

    Geomorphologists have shown increasing interest in environmental radionuclides since pioneering studies by Ritchie and McHenry in the USA and Campbell, Longmore and Loughran in Australia. Environmental radionuclides have attracted this interest because they provide geomorphologists with the means to trace sediment movement within the landscape. They, therefore, facilitate investigation of subjects at the core of geomorphology, namely the rates and patterns of landscape change. Most attention has been focussed on the artificial radionuclide caesium-137 ( 137 Cs) but more recently potential applications of the natural radionuclides lead-210 ( 210 Pb) and beryllium-7( 7 Be) have been investigated (Walling et al., 1995; Wallbrink and Murray, 1996a, 1996b). The origin, characteristics and applications of these radionuclides are summarised. These radionuclides are of value as sediment tracers because of three important characteristics: a strong affinity for sediment; a global distribution and the possibility of measurement at low concentration. Geomorphological applications of environmental radionuclides provide unique access to detailed qualitative data concerning landscape change over a range of timescales

  9. Prevention: Exercise

    Medline Plus

    Full Text Available ... body. Pilates, yoga and martial arts all provide well-rounded core strengthening programs. Simple exercises can be done at home as well. Some specific core strengthening exercises are described below. ...

  10. Compulsive Exercise

    Science.gov (United States)

    ... negative thinking and low self-esteem. Why Is Exercising Too Much a Bad Thing? We all know ... spent with friends. Warning Signs Someone may be exercising compulsively if he or she: won't skip ...

  11. Prevention: Exercise

    Medline Plus

    Full Text Available ... prescribe an exercise program that matches your abilities. Neck Press This is an isometric exercise to strengthen your neck. Press your palm against your forehead, then use ...

  12. Exercise Headaches

    Science.gov (United States)

    ... headaches may require emergency medical attention. Symptoms Primary exercise headaches These headaches: Are usually described as throbbing ... sides of the head in most cases Secondary exercise headaches These headaches may cause: The same symptoms ...

  13. Prevention: Exercise

    Medline Plus

    Full Text Available ... programs. Simple exercises can be done at home as well. Some specific core strengthening exercises are described ... times... Abdominal Crunch Draw abdominal wall inward, exhale as you lift chest area. This can be done ...

  14. Prevention: Exercise

    Medline Plus

    Full Text Available ... provide well-rounded core strengthening programs. Simple exercises can be done at home as well. Some specific ... benefit from this exercise... Sagittal Core Strengthening You can stretch and strengthen the low back muscles that ...

  15. Prevention: Exercise

    Medline Plus

    Full Text Available ... Disc Replacement (ADR) Bone Graft Alternatives Bone Morphogenetic Proteins (BMP) Cervical Disc Replacement Cervical Laminoplasty Lumbar (Open) ... Flexibility Aerobic Exercise Cervical Exercise Strength Training for the Elderly Other Back Pack Safety Pregnancy and Back ...

  16. Radionuclides in Canada goose eggs

    International Nuclear Information System (INIS)

    Rickard, W.H.; Sweany, H.A.

    1975-01-01

    Low levels of radionuclides were measured in Canada goose eggs taken from deserted nests from Columbia River islands on the Energy Research and Development Administration's Hanford Reservation. Potassium-40, a naturally occurring radionuclide, was the most abundant radionuclide measured in egg contents and egg shell. Strontium-90 was incorporated into egg shells and cesium-137 into inner egg contents. Manganese-54, cobalt-60, and zinc-65 were more abundant in inner egg contents than in egg shell. Cerium-144 was detected in egg shell but not in inner shell

  17. Radionuclide migration in water reservoirs

    International Nuclear Information System (INIS)

    Rodionova, L.F.

    1983-01-01

    Toxicity degree and radiation effect of different radionuclides depend on multiple factors, whose interaction can strengthen or weaken the effects through the mechanism of nuclide accumulation by hydrobiontes. Stage of development of an aquatic organism, its age, mass and sex as well as lifetime and residence time of the organism in the given medium are of importance. The radionuclide build up depends on illumination, locale of the bioobject residence, on the residence nature. The concentration of radionuclides in aquatic organisms and bionts survival depend on a season, temperature of the residence medium, as well as salinity and mineral composition of water influence

  18. Exercise Habit

    Science.gov (United States)

    ... chunks of time. Exercise has so many health benefits that any amount is better than none. Try exercising for 10 minutes at a time throughout your ... second hand. Most people will get the greatest benefit and lower their risks if ... rate when exercising. To figure out your maximum heart rate, subtract ...

  19. Artificial radionuclides in soil, flora and fauna

    International Nuclear Information System (INIS)

    Marej, A.N.

    1984-01-01

    Sources and ways of soil contamination by radionuclides, as well as the main regularities of radionuclide behaviour in soils, are discussed. Ways of radionuclide uptake by plants are discussed in detail, since radionuclide contamination of vegetation, and agricultural plants and pastures in particular, is one of the main factors, determining sanitary value of environmental contamination by radioactive substances

  20. Radionuclide methods in pediatric cardiology

    International Nuclear Information System (INIS)

    Reich, O.; Ruth, C.; Samanek, M.

    1990-01-01

    The use of radionuclide methods in pediatric cardiology is discussed for non-invasive evaluation of myocardial function and perfusion, regional lung perfusion and ventilation, and for measuring central and peripheral hemodynamics. (H.W.). 16 refs

  1. Radionuclide Retention in Concrete Wasteforms

    Energy Technology Data Exchange (ETDEWEB)

    Bovaird, Chase C.; Jansik, Danielle P.; Wellman, Dawn M.; Wood, Marcus I.

    2011-09-30

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how wasteform performance is affected by the full range of environmental conditions within the disposal facility; the process of wasteform aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of wasteform aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the wasteforms come in contact with groundwater. The information present in the report provides data that (1) measures the effect of concrete wasteform properties likely to influence radionuclide migration; and (2) quantifies the rate of carbonation of concrete materials in a simulated vadose zone repository.

  2. Radionuclides in the food chain

    International Nuclear Information System (INIS)

    Harley, J.H.; Schmidt, G.D.

    1988-01-01

    Radionuclides in the Food Chain reviews past experience in meeting the challenge of radionuclide contamination of foodstuffs and water sources and, in the wake of the reactor accidents at Chernobyl and Three Mile Island, presents current concepts and programs relating to measurement, surveillance, effects, risk management, evaluation guidelines, and control and regulatory activities. This volume, based on a symposium sponsored by the International Life Sciences Institute in association with the International Institute for Applied Systems Analysis, which brought together both radiation experts and food industry policymakers, examines such vital topics as structural problems in large-scale crisis-managment systems; dose assessment from man-made sources; international recommendations on radiation protection; airborne contamination, as well as aquatic and soilborne radionuclides; food-chain contamination from testing nuclear devices; long-term health effects of radionuclides in food and water supplies; and use of mathematical models in risk assessment and management. (orig.)

  3. Drift-Scale Radionuclide Transport

    International Nuclear Information System (INIS)

    Houseworth, J.

    2004-01-01

    The purpose of this model report is to document the drift scale radionuclide transport model, taking into account the effects of emplacement drifts on flow and transport in the vicinity of the drift, which are not captured in the mountain-scale unsaturated zone (UZ) flow and transport models ''UZ Flow Models and Submodels'' (BSC 2004 [DIRS 169861]), ''Radionuclide Transport Models Under Ambient Conditions'' (BSC 2004 [DIRS 164500]), and ''Particle Tracking Model and Abstraction of Transport Process'' (BSC 2004 [DIRS 170041]). The drift scale radionuclide transport model is intended to be used as an alternative model for comparison with the engineered barrier system (EBS) radionuclide transport model ''EBS Radionuclide Transport Abstraction'' (BSC 2004 [DIRS 169868]). For that purpose, two alternative models have been developed for drift-scale radionuclide transport. One of the alternative models is a dual continuum flow and transport model called the drift shadow model. The effects of variations in the flow field and fracture-matrix interaction in the vicinity of a waste emplacement drift are investigated through sensitivity studies using the drift shadow model (Houseworth et al. 2003 [DIRS 164394]). In this model, the flow is significantly perturbed (reduced) beneath the waste emplacement drifts. However, comparisons of transport in this perturbed flow field with transport in an unperturbed flow field show similar results if the transport is initiated in the rock matrix. This has led to a second alternative model, called the fracture-matrix partitioning model, that focuses on the partitioning of radionuclide transport between the fractures and matrix upon exiting the waste emplacement drift. The fracture-matrix partitioning model computes the partitioning, between fractures and matrix, of diffusive radionuclide transport from the invert (for drifts without seepage) into the rock water. The invert is the structure constructed in a drift to provide the floor of the

  4. Surface diffusion of sorbed radionuclides

    International Nuclear Information System (INIS)

    Berry, J.A.; Bond, K.A.

    1991-01-01

    Surface diffusion has in the past been invoked to explain rates of radionuclide migration which were greater than those predicted. Results were generally open to interpretation but the possible existence of surface diffusion, whereby sorbed radionuclides could potentially migrate at much enhanced rates, necessitated investigation. In this work through-diffusion experiments have shown that although surface diffusion does exist for some nuclides, the magnitude of the phenomenon is not sufficient to affect repository safety assessment modelling. (author)

  5. Radionuclide generators for biomedical applications

    International Nuclear Information System (INIS)

    Finn, R.D.; Molinski, V.J.; Hupf, H.B.; Kramer, H.

    1983-10-01

    This document reviews the chemical literature of those radionuclide generators that have gained or appear to possess utility in medical imaging. The text represents a conscientious effort to peruse the scientific literature through 1980. The intent of this work is to provide a reference point for the investigator who is interested in the development of a particular generator system and the refinements which have been reported. Moreover, the incorporation of the particular daughter radionuclide into a suitable radiodiagnostic agent is presented

  6. Radionuclide migration in soils

    Energy Technology Data Exchange (ETDEWEB)

    Demir, M [Ingenieurgesellschaft Bonnenberg und Drescher, Juelich (Germany, F.R.)

    1979-01-01

    Unplanned releases from a nuclear installation - e.g., leakage from a storage tank or other incident - can result in the escape of contaminants such as U, Pu, Cs, Sr, T etc. Nuclide transport through the ground is governed by characteristics of the subsurface hydrology and the specific nuclides under consideration. Unsaturated soil layers result in a transport rate so low as to negligible. Radionuclides reaching the ground water are assumed to endanger human life because of potential uncontrolled ingestion. The most dangerous nuclides are long-lived and not absorbed, or very poorly absorbed, in the soil. During migration of nuclides through saturated soil layers, the concentration can be reduced by dilution. Preliminary results indicate that tritium is spread with ground water velocity. Its concentration can be reduced only by diffusion, dispersion and radioactive decay. Alpha-emitters are strongly retained velocities of alpha-emitters are approximately one thousandth (10/sup -3/) that of T. Transport velocities of Cs and Sr are approximately one hundreth (10/sup -2/) and one tenth (10/sup -1/) that of T respectively.

  7. Radionuclide migration in soils

    International Nuclear Information System (INIS)

    Demir, M.

    1979-01-01

    Unplanned releases from a nuclear installation - e.g., leakage from a storage tank or other incident - can result in the escape of contaminants such as U, Pu, Cs, Sr, T etc. Nuclide transport through the ground is governed by characteristics of the subsurface hydrology and the specific nuclides under consideration. Unsaturated soil layers result in a transport rate so low as to negligible. Radionuclides reaching the ground water are assumed to endanger human life because of potential uncontrolled ingestion. The most dangerous nuclides are long-lived and not absorbed, or very poorly absorbed, in the soil. During migration of nuclides through saturated soil layers, the concentration can be reduced by dilution. Preliminary results indicate that tritium is spread with ground water velocity. Its concentration can be reduced only by diffusion, dispersion and radioactive decay. Alpha-emitters are strongly retained velocities of alpha-emitters are approximately one thousandth (10 -3 ) that of T. Transport velocities of Cs and Sr are approximately one hundreth (10 -2 ) and one tenth (10 -1 ) that of T respectively. (orig./HP) [de

  8. Radionuclide salivary gland imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1981-10-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific.

  9. Radionuclide brain scanning

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.

    1992-01-01

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  10. Radionuclide salivary gland imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1981-01-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific

  11. Radionuclide brain scanning

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Dayem, H

    1993-12-31

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ``allied advances`` with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  12. Exercise addiction

    DEFF Research Database (Denmark)

    Lichtenstein, Mia Beck; Christiansen, Erik; Elklit, Ask

    2014-01-01

    Exercise addiction is characterized by excessive exercise patterns with potential negative consequences such as overuse injuries. The aim of this study was to compare eating disorder symptoms, quality of life, personality traits and attachments styles in exercisers with and without indications...... of exercise addiction. A case-control study with 121 exercisers was conducted. The exercisers were categorized into an addiction group (n=41) or a control group (n=80) on the basis of their responses to the Exercise Addiction Inventory. The participants completed the Eating Disorder Inventory 2, the Short......-Form 36, the NEO Personality Inventory Revised and the Adult Attachment Scale. The addiction group scored higher on eating disorder symptoms, especially on perfectionism but not as high as eating disorder populations. The characteristic personality traits in the addiction group were high levels...

  13. Anthropogenic radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Q; Weng, J; Wang, J

    2007-11-15

    Studies of radionuclides in the environment have entered a new era with the renaissance of nuclear energy and associated fuel reprocessing, geological disposal of high-level nuclear wastes, and concerns about national security with respect to nuclear non-proliferation. This work presents an overview of anthropogenic radionuclide contamination in the environment, as well as the salient geochemical behavior of important radionuclides. We first discuss the following major anthropogenic sources and current development that contribute to the radionuclide contamination of the environment: (1) nuclear weapons program; (2) nuclear weapons testing; (3) nuclear power plants; (4) commercial fuel reprocessing; (5) geological repository of high-level nuclear wastes, and (6) nuclear accidents. Then, we summarize the geochemical behavior for radionuclides {sup 99}Tc, {sup 129}I, and {sup 237}Np, because of their complex geochemical behavior, long half-lives, and presumably high mobility in the environment. Biogeochemical cycling and environment risk assessment must take into account speciation of these redox-sensitive radionuclides.

  14. Exercise addiction.

    Science.gov (United States)

    Landolfi, Emilio

    2013-02-01

    This article examines the nature of exercise addiction. It presents a broad, congruent and discerning narrative literature review with the aim of providing a deeper understanding of the condition 'exercise addiction', including symptoms and options for treatment. In addition, guidelines are provided with respect to 'healthy' levels of exercise. Criteria used for determining the eligibility of studies evaluated in the review included the provision of relevant information in studies identified using pertinent search terms. The review highlights some of the key distinctions between healthy levels of exercise and exercise addiction. The findings suggest that an individual who is addicted to exercise will continue exercising regardless of physical injury, personal inconvenience or disruption to other areas of life including marital strain, interference with work and lack of time for other activities. 'Addicted' exercisers are more likely to exercise for intrinsic rewards and experience disturbing deprivation sensations when unable to exercise. In contrast, 'committed' exercisers engage in physical activity for extrinsic rewards and do not suffer severe withdrawal symptoms when they cannot exercise. Exercisers must acquire a sense of life-balance while embracing an attitude conducive to sustainable long-term physical, psychological and social health outcomes. Implementation of recommendations by the Canadian Society for Exercise Physiology, which states that all apparently healthy adults between 18 and 64 years of age should accumulate at least 150 minutes of moderate (5 or 6 on a scale of 0-10) to vigorous (7 or 8 on a scale of 0-10) intensity aerobic physical activity per week in bouts of 10 minutes or more, also expressed as 30 minutes per day distributed over 5 days per week, would be a good start.

  15. Lifestyle and age as determinates of intake and dose from inhaled radionuclides

    International Nuclear Information System (INIS)

    Fields, D.E.; Yalcintas, M.G.

    1989-01-01

    The whole-body dose from inhaled radionuclides is a complex function of factors describing exposure and physiology. Exposure-related factors may be estimated by considering likely emission rates combined with measured time-varying meteorological (transport) parameters and estimated exercise patterns. Physiological factors, strongly influencing radionuclide intake and consequent radiation dose, have been catalogued as functions of age and activity level. Both exercise patterns and physiological factors are related to age of the exposed individual. Combining these factors permits estimates to be made of the span of exposures that may be expected in a typical population. The ratio of highest to lowest radionuclide intake is predicted to be of the order of 40, suggesting that specification of an 'average' value may be misleading if this value approaches regulatory limits. Individuals exposed to maximal risk may be identified, and are likely to be active children. Activity pattern (lifestyle) is a primary determinant of risk. (author)

  16. General concepts of ventricular function, Myocardial perfusion, and exercise physiology relevant to nuclear cardiology

    International Nuclear Information System (INIS)

    Kronenberg, M.W.; Becker, L.C.

    1988-01-01

    Knowledge of ventricular mechanics, the physiology of the coronary circulation, and exercise physiology is necessary for the accurate interpretation of radionuclide ventriculographic and myocardial perfusion images. This chapter outlines these important basic concepts as applied to the whole heart

  17. The value of radionuclide angiography for risk assessment of patients following acute myocardial infarction

    International Nuclear Information System (INIS)

    Morris, K.G.

    1985-01-01

    Radionuclide angiography (RNA) is an accurate noninvasive method for the evaluation of left ventricular function at rest and exercise. Both the change in ejection fraction from rest to exercise and the exercise ejection fraction correlate with the severity of coronary artery disease and are more sensitive than ST-segment changes for detecting abnormalities due to exercise-induced myocardial ischemia. The amount of left ventricular dysfunction produced acutely by myocardial ischemia appears to vary linearly with the severity of ischemia produced. Thus rest and exercise RNA provide information noninvasively regarding both the severity of left ventricular dysfunction and the amount of potentially ischemic myocardium, two of the three major pathophysiologic mechanisms related to prognosis. It is reasonable to hypothesize that rest and exercise RNA may provide useful prognostic information concerning subsequent mortality and morbidity in survivors of acute myocardial infarction

  18. Intercomparison of radionuclide measurements in marine sediment sample IAEA-367

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Lopez, J J; Gastaud, J; Vas, D; Noshkin, V

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-367, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 81 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for {sup 60}Co, {sup 90}Sr, {sup 137}Cs, {sup 239+240}Pu (Reference date: 1 January 1990). Information values for {sup 155}Eu, {sup 238}Pu, {sup 241}Am, and {sup 241}Pu are reported. Information values for the following natural radionuclides {sup 40}K, {sup 226}Ra, {sup 228}Th, {sup 230}Th, {sup 234}U, {sup 235}U and {sup 238}U are also reported. (author)

  19. Exercise left ventricular performance in patients with chest pain, ischemic-appearing exercise electrocardiograms, and angiographically normal coronary arteries

    International Nuclear Information System (INIS)

    Berger, H.J.; Sands, M.J.; Davies, R.A.; Wackers, F.J.; Alexander, J.; Lachman, A.S.; Williams, B.W.; Zaret, B.L.

    1981-01-01

    Left ventricular performance was evaluated using first-pass radionuclide angiocardiography in 31 patients with chest pain, an ischemic-appearing exercise electrocardiogram, and angiographically normal coronary arteries at rest and during maximal upright bicycle exercise. 201 Tl imaging was done in all patients after treadmill exercise and in selected patients after ergonovine provocation. Resting left ventricular performance was normal in all patients. An abnormal ejection fraction response to exercise was detected in 12 of 31 patients. Regional dysfunction was present during exercise in four patients, all of whom also had abnormal global responses. Three of these 12 patients and two additional patients had exercise-induced 201 Tl perfusion defects. In all nine patients who underwent ergonovine testing, there was no suggestion of coronary arterial spasm. Thus, left ventricular dysfunction during exercise, in the presence of normal resting performance, was found in a substantial number of patients with chest pain, an ischemic-appearing exercise electrocardiogram, and normal coronary arteries

  20. Dosimetry in radionuclide therapy

    International Nuclear Information System (INIS)

    Riccabona, G.

    2001-01-01

    While it is known that therapeutic effects of radionuclides are due to absorbed radiation dose and to radiosensitivity, individual dosimetry in 'Gy' is practiced rarely in clinical Nuclear Medicine but 'doses' are described in 'mCi' or 'MBq', which is only indirectly related to 'Gy' in the target. To estimate 'Gy', the volume of the target, maximum concentration of the radiopharmaceutical in it and residence time should be assessed individually. These parameters can be obtained usually only with difficulty, involving possibly also quantitative SPET or PET, modern imaging techniques (sonography, CT, MRT), substitution of y- or positron emitting radiotracers for β - emitting radiopharmaceuticals as well as whole-body distribution studies. Residence time can be estimated by obtaining data on biological half-life of a comparable tracer and transfer of these data in the physical characteristics of the therapeutic agent. With all these possibilities for gross dosimetry the establishment of a dose-response-relation should be possible. As distribution of the radiopharmaceutical in lesions is frequently inhomogenous and microdosimetric conditions are difficult to assess in vivo as yet, it could be observed since decades that empirically set, sometimes 'fixed' doses (mCi or MBq) can also be successful in many diseases. Detailed dosimetric studies, however, are work- and cost-intensive. Nevertheless, one should be aware at a time when more sophisticated therapeutic possibilities in Nuclear Medicine arise, that we should try to estimate radiation dose (Gy) in our new methods even as differences in individual radiosensitivity cannot be assessed yet and studies to define individual radiosensitivity in lesions should be encouraged. (author)

  1. Radionuclide Sensors for Water Monitoring

    International Nuclear Information System (INIS)

    Grate, Jay W.; Egorov, Oleg B.; DeVol, Timothy A.

    2004-01-01

    Radionuclide contamination in the soil and groundwater at U.S. Department of Energy (DOE) sites is a severe problem that requires monitoring and remediation. Radionuclide measurement techniques are needed to monitor surface waters, groundwater, and process waters. Typically, water samples are collected and transported to an analytical laboratory, where costly radiochemical analyses are performed. To date, there has been very little development of selective radionuclide sensors for alpha- and beta-emitting radionuclides such as 90Sr, 99Tc, and various actinides of interest. The objective of this project is to investigate novel sensor concepts and materials for sensitive and selective determination of beta- and alpha-emitting radionuclide contaminants in water. To meet the requirements for loW--level, isotope-specific detection, the proposed sensors are based on radiometric detection. As a means to address the fundamental challenge of the short ranges of beta and alpha particle s in water, our overall approach is based on localization of preconcentration/separation chemistries directly on or within the active area of a radioactivity detector. Automated microfluidics is used for sample manipulation and sensor regeneration or renewal. The outcome of these investigations will be the knowledge necessary to choose appropriate chemistries for selective preconcentration of radionuclides from environmental samples, new materials that combine chemical selectivity with scintillating properties, new materials that add chemical selectivity to solid-state diode detectors, new preconcentrating column sensors, and improved instrumentation and signal processing for selective radionuclide sensors. New knowledge will provide the basis for designing effective probes and instrumentation for field and in situ measurements

  2. Performance assessment calculational exercises

    International Nuclear Information System (INIS)

    Barnard, R.W.; Dockery, H.A.

    1990-01-01

    The Performance Assessment Calculational Exercises (PACE) are an ongoing effort coordinated by Yucca Mountain Project Office. The objectives of fiscal year 1990 work, termed PACE-90, as outlined in the Department of Energy Performance Assessment (PA) Implementation Plan were to develop PA capabilities among Yucca Mountain Project (YMP) participants by calculating performance of a Yucca Mountain (YM) repository under ''expected'' and also ''disturbed'' conditions, to identify critical elements and processes necessary to assess the performance of YM, and to perform sensitivity studies on key parameters. It was expected that the PACE problems would aid in development of conceptual models and eventual evaluation of site data. The PACE-90 participants calculated transport of a selected set of radionuclides through a portion of Yucca Mountain for a period of 100,000 years. Results include analyses of fluid-flow profiles, development of a source term for radionuclide release, and simulations of contaminant transport in the fluid-flow field. Later work included development of a problem definition for perturbations to the originally modeled conditions and for some parametric sensitivity studies. 3 refs

  3. Exercise Dependence

    Directory of Open Access Journals (Sweden)

    Erdal Vardar

    2012-06-01

    Full Text Available Exercise dependence define a condition in which a person performs excessive exercise resulting in deterioration of his or her physical and mental health wellness. Despite many clinical research studies on exercise dependence, exact diagnostic criteria has not been developed yet. Clinical evidences concerning etiology, epidemiology, underlying mechanisms and treatment of exercise dependence are still not sufficient. Moreover, evaluation of this clinical disorder within dependency perspective is a fairly new concept. Recent studies have shown that exercise dependence has similar features like chemical substance dependence with regards to withdrawal and tolerance symptoms. The aim of this review was to briefly evaluate diagnostic and clinical features of exercise dependence. [Archives Medical Review Journal 2012; 21(3.000: 163-173

  4. OECOSYS prevailing exercise applications

    International Nuclear Information System (INIS)

    Mueck, K.; Suda, M.

    1999-10-01

    In the Research Center Seibersdorf the computer simulation code OECOSYS was installed in 1989 which represents a version of the model ECOSYS-87 developed by GSF in Neuherberg, and adapted to the Austrian situation. The model available since then simulates from input parameters such as the integral of the activity concentration in air and the ground deposition of each radionuclide as well as the precipitation values via the interception on plants and deposition on soil and the transfer of radionuclides into the various ecosystems and fodder-food chains into the various foodstuffs and calculates in this way the course of the activity concentration in these foodstuffs. Via the consumption rates of each foodstuff the contribution of the ingestion of each foodstuff and by that the total ingestion dose may be evaluated. Further, the simulation model permits the calculation of the various exposure pathways as inhalation and external irradiation from the plume and ground and enable the user to obtain a fast comparison of the various exposure pathways. In order to ensure the availability of the code and the accompanying infrastructure, by order of the federal chancellery sect. VI the computer code is run in certain intervals and test calculations are performed with it. Each exercise run was based on scenarios which could result in case of severe accidents in neighboring nuclear power plants. Generally, extremely unrealistic scenarios were assumed which do not correspond to the safety standard of the respective nuclear power plant in order to obtain calculation examples which may serve the emergency units in their planning for emergency situations. Furthermore, by these exercise runs a demonstration of the contribution of the various exposure pathways for the persons responsible for emergency management in case of a crisis shall be given to enable them to appropriately design the respective planning features. In the present report the calculations performed up to now are

  5. Prevention: Exercise

    Medline Plus

    Full Text Available ... Steroid Injections Lumbar Zygapophysical (Facet) Joint Injections PREVENTION Lifestyle Choices 10 Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen ...

  6. Inverse problem in radionuclide transport

    International Nuclear Information System (INIS)

    Yu, C.

    1988-01-01

    The disposal of radioactive waste must comply with the performance objectives set forth in 10 CFR 61 for low-level waste (LLW) and 10 CFR 60 for high-level waste (HLW). To determine probable compliance, the proposed disposal system can be modeled to predict its performance. One of the difficulties encountered in such a study is modeling the migration of radionuclides through a complex geologic medium for the long term. Although many radionuclide transport models exist in the literature, the accuracy of the model prediction is highly dependent on the model parameters used. The problem of using known parameters in a radionuclide transport model to predict radionuclide concentrations is a direct problem (DP); whereas the reverse of DP, i.e., the parameter identification problem of determining model parameters from known radionuclide concentrations, is called the inverse problem (IP). In this study, a procedure to solve IP is tested, using the regression technique. Several nonlinear regression programs are examined, and the best one is recommended. 13 refs., 1 tab

  7. Radionuclide Retention in Concrete Wasteforms

    Energy Technology Data Exchange (ETDEWEB)

    Wellman, Dawn M.; Jansik, Danielle P.; Golovich, Elizabeth C.; Cordova, Elsa A.

    2012-09-24

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how wasteform performance is affected by the full range of environmental conditions within the disposal facility; the process of wasteform aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of wasteform aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the wasteforms come in contact with groundwater. Data collected throughout the course of this work will be used to quantify the efficacy of concrete wasteforms, similar to those used in the disposal of LLW and MLLW, for the immobilization of key radionuclides (i.e., uranium, technetium, and iodine). Data collected will also be used to quantify the physical and chemical properties of the concrete affecting radionuclide retention.

  8. Radionuclide injury to the lung

    International Nuclear Information System (INIS)

    Dagle, G.E.; Sanders, C.L.

    1984-01-01

    Radionuclide injury to the lung has been studied in rats, hamsters, dogs, mice and baboons. Exposure of the lung to high dose levels of radionuclides produces a spectrum of progressively more severe functional and morphological changes, ranging from radiation pneumonitis and fibrosis to lung tumors. These changes are somewhat similar for different species. Their severity can be related to the absorbed radiation dose (measured in rads) produced by alpha, beta or gamma radiation emanating from various deposited radionuclides. The chemicophysical forms of radionuclides and spatial-temporal factors are also important variables. As with other forms of injury to the lung, repair attempts are highlighted by fibrosis and proliferation of pulmonary epithelium. Lung tumors are the principal late effect observed in experimental animals following pulmonary deposition of radionuclides at dose levels that do not result in early deaths from radiation pneumonitis or fibrosis. The predominant lung tumors described have been of epithelial origin and have been classified, in decreasing frequency of occurrence, as adenocarcinoma, bronchioloalveolar carcinoma, epidermoid carcinomas and combined epidermoid and adenocarcinoma. Mesothelioma and fibrosarcoma have been observed in rats, but less commonly in other species. Hemangiosarcomas were frequently observed in dogs exposed to beta-gamma emitters, and occasionally in rats exposed to alpha emitters. These morphologic changes in the lungs of experimental animals were reviewed and issues relevant to the prediction of human hazards discussed. 88 references

  9. IAEA-RML-2015-01 Proficiency Test for Determination of Radionuclides in Sea Water

    International Nuclear Information System (INIS)

    2017-01-01

    The Radiometrics Laboratory of the IAEA Environment Laboratories has provided quality support services and products to laboratories in Member States for over 50 years. They include the organization of proficiency test exercises and laboratory intercomparisons, and the production of certified reference materials with a wide range of marine sample matrices and radionuclide levels. As part of these activities, a follow-up proficiency test exercise was organized in 2015 at the request of the Nuclear Regulation Authority of Japan to continue testing the performance of participating laboratories in an analysis of radionuclides in a seawater sample. The exercise was designed to support laboratories in seawater analyses of 3H, 134Cs, 137Cs and 90Sr relating to the accident at the Fukushima Daiichi nuclear power plant, in March 2011, and the subsequent contamination of the marine environment. The results of the exercise, which are described in this publication, allow the participating laboratories to evaluate and compare their performance in the analysis of these radionuclides for this sample type. A total of 43 laboratories from 29 Member States participated from August to October 2015. Earlier exercises are described in IAEA Analytical Quality in Nuclear Applications Series Nos 40–43.

  10. Intercomparison of radionuclide measurements in marine sediment sample IAEA-368

    International Nuclear Information System (INIS)

    Ballestra, S.; Lopez, J.J.; Gastaud, J.; Parsi, P.; Vas, D.; Noshkin, V.

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-368, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 89 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for 60 Co, 155 Eu, 210 7Pb, 226 Ra, 238 U, 238 Pu and 239+240 Pu (Reference date: 1 January 1990). Information values for 40 K, 90 Sr, 137 Cs, 228 Th, 230 Th, 232 Th, 234 U, 235 U and 241 Am are also reported. (author)

  11. Method of preparing radionuclide doses

    International Nuclear Information System (INIS)

    Kuperus, J.H.

    1987-01-01

    A method is described of preparing aliquot dosea of a tracer material useful in diagnostic nuclear medicine comprising: storing discrete quantities of a lyophilized radionuclide carrier in separate tubular containers from which air and moisture is excluded, selecting from the tubular containers a container in which is stored a carrier appropriate for a nuclear diagnostic test to be performed, interposing the selected container between the needle and the barrel of a hypodermic syringe, and drawing a predetermined amount of a liquid containing a radionuclide tracer in known concentration into the hypodermic syringe barrel through the hypodermic needle and through the selected container to dissolve the discrete quantity of lyophilized carrier therein to combine the carrier with the radionuclide tracer to form an aliquot dose of nuclear diagnostic tracer material, as needed

  12. Methods of separating short half-life radionuclides from a mixture of radionuclides

    International Nuclear Information System (INIS)

    Bray, L.A.; Ryan, J.L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of 223 Ra and 225 Ac, from a radionuclide ''cow'' of 227 Ac or 229 Th respectively. The method comprises the steps of (a) permitting ingrowth of at least one radionuclide daughter from said radionuclide ''cow'' forming an ingrown mixture; (b) insuring that the ingrown mixture is a nitric acid ingrown mixture; (c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the ''cow'' from at least one radionuclide daughter; (d) insuring that the at least one radionuclide daughter contains the radionuclide product; (e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and (f) recycling the at least one radionuclide daughter by adding it to the ''cow''. In one embodiment the radionuclide ''cow'' is the 227 Ac, the at least one daughter radionuclide is a 227 Th and the product radionuclide is the 223 Ra and the first nitrate form ion exchange column passes the 227 Ac and retains the 227 Th. In another embodiment the radionuclide ''cow'' is the 229 Th, the at least one daughter radionuclide is a 225 Ra and said product radionuclide is the 225 Ac and the 225 Ac and nitrate form ion exchange column retains the 229 Th and passes the 225 Ra/Ac. 8 figs

  13. Producing new radionuclides for medicine

    International Nuclear Information System (INIS)

    Michaut, C.

    2009-01-01

    The Arronax cyclotron, a new particle accelerator dedicated to the production of radionuclides for medicine and research has been commissioned in Nantes (France). Because of its unique features: an energy of 70 MeV and an intensity of 750 μA, Arronax will produce radionuclides that can not be produce in present cyclotrons. Among others it will produce Strontium-82 and Germanium-68 that are the precursors for Rubidium-82 and Gallium-68 respectively. 20 per cent of the research works will be dedicated to other domains like radioactive wastes, the radiation biological damage and the radiation damage on electronic devices. (A.C.)

  14. Radionuclide migration in geological formations

    International Nuclear Information System (INIS)

    Barbreau, A.; Heremans, R.; Skytte Jensen, B.

    1980-01-01

    Radioactive waste disposal into geological formation is based on the capacity of rocks to confine radioactivity for a long period of time. Radionuclide migration from the repository to the environment depends on different mechanisms and phenomena whose two main ones are groundwater flow and the retention and ion-exchange property of rocks. Many studies are underway presently in EEC countries concerning hydrodynamic characteristics of deep geological formations as well as in radionuclide retention capacity and modelling. Important results have already been achieved which show the complexity of some phenomena and further studies shall principally be developed taking into account real conditions of the repository and its environment

  15. Automatic alignment of radionuclide images

    International Nuclear Information System (INIS)

    Barber, D.C.

    1982-01-01

    The variability of the position, dimensions and orientation of a radionuclide image within the field of view of a gamma camera hampers attempts to analyse the image numerically. This paper describes a method of using a set of training images of a particular type, in this case right lateral brain images, to define the likely variations in the position, dimensions and orientation for that type of image and to provide alignment data for a program that automatically aligns new images of the specified type to a standard position, size and orientation. Examples are given of the use of this method on three types of radionuclide image. (author)

  16. Radionuclide techniques for brain imaging

    International Nuclear Information System (INIS)

    Cowan, R.J.; Moody, D.M.

    1984-01-01

    Over the past decade, many of the prime indications for radionuclide brain scanning have become instead indications for CCT, and nuclear medicine studies of the brain have assumed more of a complementary, supportive role. However, there is great promise for improvement in central nervous system radionuclide applications with advances anticipated in both radiopharmaceuticals and instrumentation. Nuclear medicine is continuing to function as a powerful research tool and, in the relatively near future, may regain its role as a major clinical test of the central nervous system

  17. Determination of alpha radionuclides in fish

    International Nuclear Information System (INIS)

    Pernicka, L.; Matel, L.; Rosskopfova, O.

    2001-01-01

    In atmospheric water, external water and undercurrent the occurrence of radionuclides is usual. It is an important factor of quality of the environment. Plants ingest radionuclides from water and with they everyone. And it arises radioactivity infest food-chain. Radiotoxicity of this radionuclides is very deer sometimes. The sensitive radiochemical procedures for their determination are necessarily important. The poster presents the combined procedure used at our laboratory for determination of alpha radionuclides in biological samples. (authors)

  18. Assessment of left ventricular function: comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis

    International Nuclear Information System (INIS)

    Gottsauner-Wolf, M.; Schedlmayer-Duit, J.; Porenta, G.; Gwechenberger, M.; Huber, K.; Glogar, D.; Probst, P.; Sochor, H.

    1996-01-01

    Measurement of global left ventricular function is important in the follow-up of cardiac patients and is a good prognostic indicator in acute cardiac situations. We compared quantitative measurements of global left ventricular function made with radionuclide angiography (RNA) and contrast cardiac ventriculography (CVG) to visual semiquantitative estimates from two-dimensional echocardiographic images (2D-echo). Three hundred and thirty-nine consecutive patients who underwent RNA were assessed with 2D-echo within 3 months. In addition, 92 of these patients also underwent CVG (correlation of ejection fraction between CVG and RNA: r=0.82; P<0.0001). The RNA mean ejection fractions in the four 2D-echo groups (0=normal, 1=slightly, 2=moderate, or 3=severe reduced left ventricular function) differed markedly (P<0.0001); however, there was overlapping among the groups (2D-echo score/RNA ejection fraction: 0=57.3%±12.8%; 1=46.0%±12.9%; 2=29.6%± 12.2%; and 3=24.6%±11.5%) and the difference between 2D-echo scores 2 and 3 was not significant. 2D-echo showed a good concordance in RNA classes (0=≥505; 1=35%-49%; 2=21%-34%; and 3=≤20% ejection fraction) 0 (133/166; 80%) and 3 (18/30; 60%) but low concordance in classes 1 (27/82; 33%) and 2 (21/61; 34%). For accurate assessment of global left ventricular ejection fraction, visual semiquantitative judgement of a 2D echocardiographic image is limited in comparison to CVG or RNA, especially in patients with a slight or moderate reduction in left ventricular ejection fraction. (orig.). With 2 figs., 2 tabs

  19. Naturally occurring radionuclides in food

    International Nuclear Information System (INIS)

    Djujic, I.

    1995-01-01

    The naturally occurring radionuclides are the major source of radiation exposure to humans. The principal way of natural radiation exposure is the inhalation of 222 Rn decay products (about 85% of the total). The remainder is equally divided between internally deposited radionuclides, cosmic and terrestrial sources. In the present study, the content of 40 K, 210 Pb, 226 Ra, 230 Th, 232 Th and 238 U in representative food samples (milk, pork, beef, potatoes, wheat and corn flour) and samples of different food items that do not represent entire national production but provide interesting additional data for approximative calculation of naturally occurring radionuclide intake is presented. Daily weight of food eaten, participation of food groups, as well as daily intake by food of mentioned naturally occurring radionuclides in the Serbian diet was obtained on the base of house hold budget surveys. The result obtained for daily intake estimates in mBq for Serbian population are 78.1 ( 40 K), 38.2( 210 Pb), 52.3( 226 Ra), 2.0( 230 Th) and 12.5( 238 U). (author)

  20. 100 Years of radionuclide metrology

    International Nuclear Information System (INIS)

    Judge, S.M.; Arnold, D.; Chauvenet, B.; Collé, R.; De Felice, P.; García-Toraño, E.; Wätjen, U.

    2014-01-01

    The discipline of radionuclide metrology at national standards institutes started in 1913 with the certification by Curie, Rutherford and Meyer of the first primary standards of radium. In early years, radium was a valuable commodity and the aim of the standards was largely to facilitate trade. The focus later changed to providing standards for the new wide range of radionuclides, so that radioactivity could be used for healthcare and industrial applications while minimising the risk to patients, workers and the environment. National measurement institutes responded to the changing demands by developing new techniques for realising primary standards of radioactivity. Looking ahead, there are likely to be demands for standards for new radionuclides used in nuclear medicine, an expansion of the scope of the field into quantitative imaging to facilitate accurate patient dosimetry for nuclear medicine, and an increasing need for accurate standards for radioactive waste management and nuclear forensics. - Highlights: • The driving forces for the development of radionuclide metrology. • Radium standards to facilitate trade of this valuable commodity in the early years. • After 1950, focus changes to healthcare and industrial applications. • National Measurement Institutes develop new techniques, standards, and disseminate the best practice in measurement. • Challenges in nuclear medicine, radioactive waste management and nuclear forensics

  1. Chemistry and analysis of radionuclides

    CERN Document Server

    Lehto, Jukka

    2010-01-01

    Written by chemists for chemists, this is a comprehensive guide to the important radionuclides as well as techniques for their separation and analysis. It introduces readers to the important laboratory techniques and methodologies in the field, providing practical instructions on how to handle nuclear waste and radioactivity in the environment.

  2. Radionuclide migration studies in soil

    International Nuclear Information System (INIS)

    Marumo, J.T.

    1989-01-01

    In this work a brief description about retention and migration parameters of radionuclides in soil, including main methods to determine the distribution coefficient (K) are given. Some of several factors that can act on the migration are also mentioned. (author) [pt

  3. Measurement of radionuclides in waste packages

    Science.gov (United States)

    Brodzinski, R.L.; Perkins, R.W.; Rieck, H.G.; Wogman, N.A.

    1984-09-12

    A method is described for non-destructively assaying the radionuclide content of solid waste in a sealed container by analysis of the waste's gamma-ray spectrum and neutron emissions. Some radionuclides are measured by characteristic photopeaks in the gamma-ray spectrum; transuranic nuclides are measured by neutron emission rate; other radionuclides are measured by correlation with those already measured.

  4. Exercise and Posture

    Science.gov (United States)

    ... About Spondylitis › Treatment Information › Exercise & Posture Print Page Exercise Exercise is an integral part of any spondylitis ... For First Responders For Chiropractors Research Article Archive Exercise Guidelines Having an exercise program that accomplishes your ...

  5. Crew Exercise

    Science.gov (United States)

    Rafalik, Kerrie K.

    2017-01-01

    Johnson Space Center (JSC) provides research, engineering, development, integration, and testing of hardware and software technologies for exercise systems applications in support of human spaceflight. This includes sustaining the current suite of on-orbit exercise devices by reducing maintenance, addressing obsolescence, and increasing reliability through creative engineering solutions. Advanced exercise systems technology development efforts focus on the sustainment of crew's physical condition beyond Low Earth Orbit for extended mission durations with significantly reduced mass, volume, and power consumption when compared to the ISS.

  6. Exercise KATRINE

    International Nuclear Information System (INIS)

    Clahane, Darren; Burgoyne, William

    1995-01-01

    Based on a hypothetical incident at the Scottish Nuclear Ltd Torness AGR nuclear power station, Exercise KATRINE was the 1994 national civil nuclear exercise and the biggest simulation of a nuclear accident to take place in Britain last year. The exercise, held on 17 and 18 November, was based on a series of postulated faults which resulted in an uncontrolled release of radioactivity. It commenced at 07.00 on Thursday and continued for about 33 hours, until around 15.30 on Friday. Activity focused on the Torness Off-site Centre (TOSC), in Cockenzie near Edinburgh, and the brand new Torness Media Briefing Centre (TMBC) located nearby. (author)

  7. Status report on radionuclide transfer

    International Nuclear Information System (INIS)

    1980-01-01

    At the suggestion of the Federal Minstry of the Interior, in June 1978, a group of scientists from several institutions who are active in the field of radionuclide transfer or are interested in these problems got together. During the discussions of the work team, especially the transfer soil/plants was emphasized. Then the work team set up a status report on the transfer of the radionuclides relevant in the sense of the radiation protection act. The nuclides H 3 and C14, the isotopes of the Sr, J, and Cs, Tc99, the so-called corrosion nuclides Mn54, Fe59, co-isotopes and Zn65, and isotopes of Pu, Am, and Cm were regarded as important for a possible radiation exposition. Recent investigations revealed that also the natural radionuclides Ra226, Po210, and Pb210 should be covered by the investigations. The goal of this status report is to present the level of knowledge on the transfer of these radionuclides to man in a brief form, giving hints at the most important literature. It was requested by the Federal Ministry of the Interior, as fas as possible, to indicate transfer factors which are necessary for the radio-occology act to be decreed according to Para. 45 of the radiation protection act. Another goal of the report was to show the gap in the knowledge on the radio nuclide transfer. This was thought to help to create a basis for the decisions of the Federal Ministry concerning the support of other investigation projects in the field of transfer of radionuclides. (orig./MG) [de

  8. Report on the intercomparison run IAEA-307 radionuclides in sea plant

    International Nuclear Information System (INIS)

    Veglia, A.; Ballestra, S.; Vas, D.

    1989-10-01

    The results of an intercomparison exercise on a Mediterranean Sea plant sample, coded as IAEA-307, designed for the determination of artificial and natural radionuclide levels, are reported. This sample was collected along the shore from the vicinity of the Principality of Monaco in October 1986. The data from 66 laboratories representing 31 countries have been evaluated. The most frequently measured radionuclides: 106 Ru, 110m Ag, 134 Cs, 137 Cs, 238 Pu, 239+240 Pu, 241 Am, 40 K and 226 Ra. 10 refs, 38 tabs

  9. Report on the intercomparison run IAEA-352 radionuclides in tuna fish flesh

    International Nuclear Information System (INIS)

    Ballestra, S.; Vas, D.; Lopez, J.J.; Noshkin, V.

    1990-08-01

    The results of an intercomparison exercise on a sample of tuna fish flesh from the Mediterranean Sea, IAEA-352, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 63 laboratories from 31 countries have been evaluated. The following are the recommended values, with confidence intervals, for the most frequently measured radionuclides (Reference data: 1 January 1989): 137 Cs 2.7 Bq kg -1 , 90 Sr 0.2 Bq Kg -1 , 40 K 391 Bq Kg -1 , 210 Pb 0.6 Bq Kg -1 , 210 Po 2.2 Bq Kg -1 . Tabs

  10. Comparison of biospheric models of radionuclides transfer

    International Nuclear Information System (INIS)

    Garcia-Olivares, A.; Carrasco, E.

    1992-01-01

    The international BIOMOVS A4 exercise has made possible that a set of biospheric transfer models could predict the daily radionuclide concentration in soils, forage and some animal products (cow milk and beef) after the Chernobyl accident. The aim was to compare these predictions with experimental results in 13 locations around the world. The data provided were essentially the daily air contamination and precipitation and some site-dependent parameters. It was a blind test, the locations and experimental measures were not revealed in advance. Twenty-three models (quasi-steady state and time-dependent models) were involved in the study. In this paper an explicit criterion has been used in order to select the models that better fitted the experimental results. In nine selected locations a comparative analysis between these models has been carried out for obtaining the structural and parametric coincidences that could explain their relatively good performance. The first evidence obtained has been that a wide set of models were able to predict the order of magnitude of the nuclides time-integrated concentrations in several important biospheric comportments. But only a few models, all of them with a 'dynamical' structure, fitted the daily behavior with the reasonable agreement. The dynamical structure of the five most successful models at predicting for Caesium 137 (CIRCLE, ECOSYS, PATHWAY, PRYMA and RAGTIME) shows some common patterns that may be relevant for a better modelling of nuclear accident scenarios. (author)

  11. Radionuclide angiocardiography in the diagnosis of congenital heart disorders

    International Nuclear Information System (INIS)

    Jones, R.H.; Austin, E.H.; Peter, C.A.; Sabiston, D.C. Jr.

    1981-01-01

    Radionuclide angiocardiography provides a noninvasive assessment of cardiac function and blood flow through the heart and lungs. During the past three years, this procedure has been used at the Duke University Medical Center for evaluation of 343 patients with congenital heart disorders. A review of this experience shows tat the resulting data were frequently useful in the surgical management of these patients. In patients with abnormal blood flow patterns, noninvasive imaging of blood flow was useful before and after operative correction. Radionuclide measurements of left-to-right intracardiac shunts were sufficiently accurate for use in the initial evaluation of patients with murmurs and to document the absence of shunt after operative closure of intracardiac septal defects. Moreover, measurements of right-to-left cardiac shunts were of benefit in the management of children with cyanotic heart disease. Measurements of left ventricular function obtained during rest and exercise were most useful in patients with origin of the left coronary artery from the pulmonary artery and in patients with congenital valvular insufficiency. This experience demonstrates that radionuclide angiocardiography provides important measurements of central hemodynamics and cardiac function which are useful in the management of patients with congenital heart disorders

  12. Prevention: Exercise

    Medline Plus

    Full Text Available ... support for your body. Pilates, yoga and martial arts all provide well-rounded core strengthening programs. Simple ... use progressively heavier balls, you will experience more benefit from this exercise... Sagittal Core Strengthening You can ...

  13. Prevention: Exercise

    Medline Plus

    Full Text Available ... Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! Stretching/Flexibility Aerobic ... Strength Training for the Elderly Other Back Pack Safety Pregnancy and Back Pain Preventing Osteoporosis Back Pain ...

  14. Intercomparison exercises

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2007-01-01

    Intercomparison exercises are vital to many a national programmes. These are only tools available with the laboratories to prove their competence to an international audience and also for the accrediting agencies to assess a laboratory

  15. Compulsive exercise

    DEFF Research Database (Denmark)

    Lichtenstein, Mia Beck; Hinze, Cecilie Juul; Emborg Jannsen, Bolette

    2017-01-01

    found that compulsive exercise is associated with eating disorder pathology, perfectionism, neuroticism, narcissism, and obsessive compulsive traits. The most prominent negative consequences were injuries, social impairment, and depression, but more research is needed to uncover the potential......Compulsive exercise is a condition described since 1970s. It is characterized by a craving for physical training, resulting in uncontrollable excessive exercise behavior with harmful consequences, such as injuries and impaired social relations. It has not been accepted as a mental disorder...... dysfunction resulting from compulsive exercise. As the condition is not recognized as a psychiatric disorder, studies on treatment interventions are sparse. Problems with compliance have been reported; therefore, motivational interviewing has been proposed as a treatment approach, in combination...

  16. Prevention: Exercise

    Medline Plus

    Full Text Available ... Physical Therapy Postural Training Traction Watchful Waiting and Education Injection Treatments for ... Core Strengthening Many popular forms of exercise focus on core strengthening, or building the muscles that provide ...

  17. Prevention: Exercise

    Medline Plus

    Full Text Available ... following suggested exercises increases your back pain after five repetitions, or causes acute pain, you should stop ... 10 seconds working towards 30 seconds. Repeat 1-5 times or to fatigue... Prone Bridge/Plank Prop ...

  18. Prevention: Exercise

    Medline Plus

    Full Text Available ... Lifestyle Choices 10 Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! ... in a straight line. Hold for 10 seconds working towards 30 seconds. Repeat 1-5 times or ...

  19. Prevention: Exercise

    Medline Plus

    Full Text Available ... Chronic Low Back Pain SI Joint Pain Other Scoliosis Back Pain and Emotional Distress Muscle Spasms Pinched ... DC Directional Exercises Electrothermal Modalities Ergonomic Changes Hydrotherapy Manual Therapy Physical Therapy Postural Training Traction Watchful Waiting and ...

  20. Prevention: Exercise

    Medline Plus

    Full Text Available ... weights (hand-held or training machines) or using isometric techniques. Common household items (like small canned goods) ... matches your abilities. Neck Press This is an isometric exercise to strengthen your neck. Press your palm ...

  1. Prevention: Exercise

    Medline Plus

    Full Text Available ... 10 Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! Stretching/Flexibility ... Pain Preventing Osteoporosis Back Pain Basics Book RESOURCES Patient Information Feature Articles Patient Q&A Success Stories ...

  2. Prevention: Exercise

    Medline Plus

    Full Text Available ... slow full movements. Repeat 10-15 times, to fatigue... Abdominal Exercise Lay on your back with both ... Return leg and extend other leg. Repeat to fatigue, about 10-15 repetitions at a slow and ...

  3. Prevention: Exercise

    Medline Plus

    Full Text Available ... 15 repetitions at a slow and controlled pace... Resistance Training Resistance training is exercise done against something providing resistance. It can be done with weights (hand-held ...

  4. Prevention: Exercise

    Medline Plus

    Full Text Available ... legs to touch the wall, keeping hips and knees bent. Use your hips to push your body ... Abdominal Exercise Lay on your back with both knees bent. Draw abdominal wall in. Maintaining abdominal wall ...

  5. Conditions and processes affecting radionuclide transport

    Science.gov (United States)

    Simmons, Ardyth M.; Neymark, Leonid A.

    2012-01-01

    Characteristics of host rocks, secondary minerals, and fluids would affect the transport of radionuclides from a previously proposed repository at Yucca Mountain, Nevada. Minerals in the Yucca Mountain tuffs that are important for retarding radionuclides include clinoptilolite and mordenite (zeolites), clay minerals, and iron and manganese oxides and hydroxides. Water compositions along flow paths beneath Yucca Mountain are controlled by dissolution reactions, silica and calcite precipitation, and ion-exchange reactions. Radionuclide concentrations along flow paths from a repository could be limited by (1) low waste-form dissolution rates, (2) low radionuclide solubility, and (3) radionuclide sorption onto geological media.

  6. Radionuclide transfer from mother to embryo

    International Nuclear Information System (INIS)

    Toader, M.; Vasilache, R.A.; Scridon, R.; Toader, M.L.

    1998-01-01

    The transfer of radionuclides from mother to embryo is still a matter of high interest. Therefore, the relation was investigated between the amount of radionuclides in the embryo and the dietary intake of the mother, this for two scenarios: a recurrent intake of variable amounts of radionuclides, and a long-term intake of a relatively constant amount of radionuclides, the radionuclide being 137 Cs. In the first case, the amount of radionuclides present in the embryo increases with the age of the embryo and with the intake of the mother. In the second case, no correlation could be found between the age of the embryo and its radioactive content; only the correlation between the intake of the mother and the radionuclide content of the embryo remained. (A.K.)

  7. Speciation analysis of radionuclides in the environment - NSK-B SPECIATION project report 2009

    International Nuclear Information System (INIS)

    Hou, X.; Aldahan, A.; Possnert, G.; Lujaniene, G.; Lehto, J.; Skipperud, L.; Lind, O.C.; Salbu, B.

    2009-10-01

    The second stage of the NKS-B project SPECIATION was complemented in 2008-2009, which mainly focus on three aspects: (1) Further improvement and development of methods for speciation analysis of radionuclides; (2) Investigation of speciation of some radionuclides in the environment (water, sediments, particles); and (3) Intercomparison excise for speciation analysis of radionuclides in soil and sediment. This report summarizes the work completed in the project partners' laboratories. Method developments include: Development of an rapid and in-suit separation method for the speciation analysis of 129I in seawater samples; Development of a simple method for the speciation analysis of 129I in fresh water and seawater samples; Development of an on-line HPLC-ICP-MS method for the direct speciation analysis of 127I in water and leachate samples; Speciation of radionuclides in water includes: Speciation of 129I and 127I in time-series precipitation samples collected in Denmark 2001-2006 and its application for the investigation of geochemistry and atmospheric chemistry of iodine, Speciation of radionuclides in Ob and Yenisey Rivers, and Speciation of 129I and 127I in Lake Heimdalen water. Speciation of radionuclides in soils and sediments includes: Sequential extraction of radionuclides in sediments and of trace elements in soil samples. Sequential extraction of radionuclides in aerosols and particles has also been performed. Furthermore, sorption experiments have been performed to investigate the association of Pu, Am and Cs with different geological materials. The intercomparison exercises included sequential extraction of Pu, 137Cs, U, Th, and 129I in one soil and one sediment standard reference materials (NIST-4354, IAEA-375) and Pu in sediment collected from the Lake Heimdalen, Norway. (author)

  8. Speciation analysis of radionuclides in the environment - NSK-B SPECIATION project report 2009

    Energy Technology Data Exchange (ETDEWEB)

    Hou, X. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Aldahan, A. (Uppsala Univ., Dept. of Earth Science (Sweden)); Possnert, G. (Uppsala Univ., Tandem Lab. (Sweden)); Lujaniene, G. (Univ. of Helsinki, Lab. of Radiochemistry (Finland)); Lehto, J. (Institute of Physics (Lithuania)); Skipperud, L.; Lind, O.C.; Salbu, B. (Norwegian Univ. of Life Sciences, Isotope Lab., AAs (Norway))

    2009-10-15

    The second stage of the NKS-B project SPECIATION was complemented in 2008-2009, which mainly focus on three aspects: (1) Further improvement and development of methods for speciation analysis of radionuclides; (2) Investigation of speciation of some radionuclides in the environment (water, sediments, particles); and (3) Intercomparison excise for speciation analysis of radionuclides in soil and sediment. This report summarizes the work completed in the project partners' laboratories. Method developments include: Development of an rapid and in-suit separation method for the speciation analysis of 129I in seawater samples; Development of a simple method for the speciation analysis of 129I in fresh water and seawater samples; Development of an on-line HPLC-ICP-MS method for the direct speciation analysis of 127I in water and leachate samples; Speciation of radionuclides in water includes: Speciation of 129I and 127I in time-series precipitation samples collected in Denmark 2001-2006 and its application for the investigation of geochemistry and atmospheric chemistry of iodine, Speciation of radionuclides in Ob and Yenisey Rivers, and Speciation of 129I and 127I in Lake Heimdalen water. Speciation of radionuclides in soils and sediments includes: Sequential extraction of radionuclides in sediments and of trace elements in soil samples. Sequential extraction of radionuclides in aerosols and particles has also been performed. Furthermore, sorption experiments have been performed to investigate the association of Pu, Am and Cs with different geological materials. The intercomparison exercises included sequential extraction of Pu, 137Cs, U, Th, and 129I in one soil and one sediment standard reference materials (NIST-4354, IAEA-375) and Pu in sediment collected from the Lake Heimdalen, Norway. (author)

  9. Radionuclide behavior at underground environment

    International Nuclear Information System (INIS)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal

  10. Choice of radionuclides for radioimmunotherapy

    International Nuclear Information System (INIS)

    DeNardo, S.J.; Jungerman, J.A.; DeNardo, G.L.; Lagunas-Solar, M.C.; Cole, W.C.; Meares, C.F.

    1985-01-01

    Innumerable questions need to be answered and obstacles overcome before radioimmunotherapy can be generally successful in cancer patients. Major developments have greatly enhanced the likelihood of success. The important development of appropriate radionuclides and radiochemistry for this therapy must be intimately linked with the biological and biochemical realities. All aspects must be considered, such as the specific nature of the antigenic target, the pharmacokinetics of the antibody fragment carrier, the capability of in vivo quantitation of tumor uptake and turnover time, as well as total body kinetics. With this knowledge, then, practical radiochemistry methods can be integrated with the suitable radionuclide choices, and production methods can be developed which will deliver effective and dependable products for patient therapy

  11. Radionuclide transfer in terrestrial animals

    International Nuclear Information System (INIS)

    DiGregorio, D.; Kitchings, T.; Van Voris, P.

    1978-01-01

    The analysis of dispersion of radionuclides in terrestrial food chains, generally, is a series of equations identifying the fractional input and outflow rates from trophic level to trophic level. Data that are prerequisite inputs for these food chain transport models include: (1) identification of specific transport pathway, (2) assimilation at each pathway link, and (3) the turnover rate or retention function by successive receptor species in the appropriate food chain. In this report, assimilation coefficients, biological half-lives, and excretion rates for a wide variety of vertebrate and invertebrate species and radionuclides have been compiled from an extensive search of the available literature. Using the information accumulated from the literature, correlations of nuclide metabolism and body weight are also discussed. (author)

  12. Applications of radionuclides in industry

    International Nuclear Information System (INIS)

    Leveque, P.

    1955-01-01

    After a brief recall of a few concepts (mass number, charge and beams properties) and the description of used detectors (ionization chamber, Geiger-Mueller counter, scintillation counters), some radionuclides applications are described. In a first part, the well-developed applications are presented in three distinct groups: continuous applications such as β and γ gauges (determination hydrogen content of an hydrocarbon and content of an emulsion; discharge of static electricity), discontinuous applications such as radiography and autoradiography, wear or manufacture problems (distribution of a fungicide on tobacco) and finally, applications in research laboratories such as diffusion, exchange and solubility. It also describes the applications which are still in development such as the action of beams on matter (reticulation and degradation of polymers, monomers polymerisation, cold sterilization). In conclusion, few advices on the opportunity of such applications and the choice of the radionuclides are given. (M.P.)

  13. Radionuclide imaging of musculoskeletal infection

    International Nuclear Information System (INIS)

    Palestr, Christopher J.; North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY; Love, Charito

    2007-01-01

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  14. Radionuclide behavior at underground environment

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal.

  15. Radionuclide imaging of musculoskeletal infection

    Energy Technology Data Exchange (ETDEWEB)

    Palestr, Christopher J. [Albert Einstein College of Medicine, Bronx, NY (United States); North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging; E-mail: palestro@lij.edu; Love, Charito [North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging

    2007-09-15

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  16. Terrestrial pathways of radionuclide particulates

    International Nuclear Information System (INIS)

    Boone, F.W.; Ng, Y.C.

    1981-01-01

    Formulations are developed for computing potential human intake of 13 radionuclides via the terrestrial food chains. The formulations are an extension of the NRC methodology. Specific regional crop and livestock transfer and fractional distribution data from the southern part of the U.S.A. are provided and used in the computation of comparative values with those computed by means of USNRC Regulatory Guide 1.109 formulations. In the development of the model, emphasis was also placed on identifying the various time-delay compartments of the food chains and accounting for all of the activity initially deposited. For all radionuclides considered, except 137 Cs, the new formulations predict lower potential intakes from the total of all food chains combined than do the comparable Regulatory Guide formulations by as much as a factor of 40. For 137 Cs the new formulations predict 10% higher potential intakes. (author)

  17. Radionuclide cinematography of the heart

    International Nuclear Information System (INIS)

    Adam, W.E.; Sigel, H.; Geffers, H.; Bitter, F.; Meyer, G.; Kampmann, H.; Stauch, M.

    1976-01-01

    Radionuclide cinematography is described as a procedure making use of radiation-level variations above the heart after equipartitioning of sup(99m)Tc-labelled human serum albumin in the blood pool. Regional ventricular and vestibular variations are phase-shifted. This procedure permits delineation of aneurysmas with interphasic course, cicatrization of the cardiac wall not producing any cyclical variation. The study included normal subjects and 16 patients with full course infarction. Characteristic disturbances of motility distribution were found in all cases of scarred or aneurysmic alterations in the frontal and side walls of the left ventricle. The procedure was unable to detect two small infarction scars on the rear wall. The possibility of using radionuclide cinematography to prove coronary insufficiency as well as a comparison with other methods are discussed

  18. Informal workshop on radionuclide laboratories. Issue 1

    International Nuclear Information System (INIS)

    2001-01-01

    The network of radionuclide stations in the International Monitoring System (IMS) of the Comprehensive Test Ban Treaty (CTBT) will be comprised of 80 monitoring stations and 16 laboratories acting in support of the monitoring stations. The 16 radionuclide laboratories have been designated but there are issues to resolve in several areas: - Fee structure and payments to the laboratories from the PTS; - Agreement on Detailed requirements for certification of the laboratories; - Duties of the laboratory To help provide technical information in these and other areas an Informal Workshop was held on January 29th - February 2nd 2001 at Atomic Weapons Establishment (AWE) United Kingdom. It was agreed that a common fee structure would make for a more efficient operation if one could be agreed. One possible fee structure for payment to the laboratories was considered to be an annual fixed fee for service (estimated at $38,000) plus a charge for each individual analysis (estimated at $1,200). These estimated values were based on the laboratory replies to a questionnaire organised by the PTS in December 2000. An average of 40 samples/year/ laboratory was considered to be the number required to maintain support to the monitoring station network and also maintain the laboratory capability. Based on this number the overall cost, payable to the laboratories, of running a network of 16 radionuclide laboratories was estimated at $1.38M per year, when all 80 radionuclide stations are operational. The first proficiency test exercise had been carried out in November 2000 and was discussed. Overall the results were highly encouraging and any minor problems found were being addressed. The technical areas requiring further consideration were uncertainty values and cascade summing corrections. The basis for an ongoing programme of such exercises was discussed and agreed by participants. One recommendation that came out of this meeting was the desirability of using a common nuclear data

  19. Radionuclide 252Cf neutron source

    International Nuclear Information System (INIS)

    Kolevatov, Yu.I.; Trykov, L.A.

    1979-01-01

    Characteristics of radionuclide neutron sourses of 252 Cf base with the activity from 10 6 to 10 9 n/s have been investigated. Energetic distributions of neutrons and gamma-radiation have been presented. The results obtained have been compared with other data available. The hardness parameter of the neutron spectrum for the energy range from 3 to 15 MeV is 1.4 +- 0.02 MeV

  20. Radionuclide diagnosis of Meckel's diverticulum

    International Nuclear Information System (INIS)

    Conway, J.J.; Northwestern Univ., Chicago, IL

    1980-01-01

    Meckel's diverticulum can be detected with a high degree of accuracy by radionuclide scintigraphy using technetium-99m pertechnetate. The technique is without risk and should precede roentgenographic studies when the diagnosis is suspected. The method is described and the causes for false positive and false negative examinations are discussed. False negatives are rare and false positives are usually secondary to other surgical entities. Overall accuracy is 85 to 90%. (orig.) [de

  1. Radionuclides for therapy: a review

    International Nuclear Information System (INIS)

    Roesler, H.; Noelpp, U.; Triller, K.J.; Steffen, R.

    1986-01-01

    Progress in angiographic techniques has been a gradual evolutionary development which now permits the selective and superselective access to a tumor's vascular bed. A diagnostic angiographic procedure can be supplemented by a one-step, quick application of embolizing radioactive material. This endoarterial radionuclide embolizing tumor therapy has the maximum selectivity among radiotherapeutic methods, with the highest radiation doses to the tumor and neglectible exposure of normal tissue. Spread of radioactivity by diffusion or leaching can be prevented

  2. Radionuclide dispersion in the atmosphere

    International Nuclear Information System (INIS)

    Moura Neto, C. de; Amorim, E.S. do; Panetta, J.

    1979-05-01

    The instantaneous liberation of radionuclides in the atmosphere is studied in three dimensions, according to the formalism of the diffusion theory. The analytical solution, expose to gravitational and an atmospherical effects, is combined with the discretization of space and time in the calculation of levels of exposure. A typical inventory (for a PWR) was considered in the calculation of immersion doses, and the results permitted a comparative analysis among the different existing models. (Author) [pt

  3. Radiation protection in radionuclide investigations

    International Nuclear Information System (INIS)

    Taylor, D.M.

    1985-01-01

    The subject is covered in sections: introduction; radiation and radioactivity; alpha particles; beta particles; neutrons; electromagnetic radiation; units of radioactivity and radiation; biological effects of radiation; the philosophy of radiation protection (ALARA principle); practical aspects of radiation protection; work with unsealed radiation sources; radionuclide studies in experimental animals; radiation safety during clinical investigations; legislative control of radiation work; radioactive waste disposal; emergency procedures; conclusion. (U.K.)

  4. Radionuclide evaluation of renal transplants

    International Nuclear Information System (INIS)

    Yang Hong; Zhao Deshan

    2000-01-01

    Radionuclide renal imaging and plasma clearance methods can quickly quantitate renal blood flow and function in renal transplants. They can diagnose acute tubular necrosis and rejection, renal scar, surgical complications such as urine leaks, obstruction and renal artery stenosis after renal transplants. At the same time they can assess the therapy effect of renal transplant complications and can also predict renal transplant survival from early post-operative function studies

  5. Ventricular and myocardial scintiscanning: Methodical fundamentals

    International Nuclear Information System (INIS)

    Standke, R.; Hoer, G.; Maul, F.D.

    1984-01-01

    Nuclear cardiology is concerned with non invasive procedures to quantitate global and regional left ventricular function (Radionuclide ventriculography), also the imaging of vitally perfused myocardium (Myocardial scintigraphy) is achieved. A gammacamera and a minicomputer are necessary. Radionuclide ventriculography enables the analysis of global and regional time dependent left ventricular volume curves and hence the evaluation of contraction and contractility of the heart muscle. The basis is a sequence of scans covering an average heartcycle. This sequence may be produced either by first pass or equilibrium technique. Myocardial scintigraphy at rest images vital myocardium, scans immediately after exercise represent the interference of myocardial perfusion and muscle mass. The regional difference (Redistribution) between normalized exercise- and rest scans provide quantitative parameters to detect impairment of exercise-induced myocardial perfusion anomalies. The procedures of sectorial analysis of left ventricular function and myocardial perfusion are presented. (orig.) [de

  6. Radionuclide behavior in the environment

    International Nuclear Information System (INIS)

    Tveten, U.

    1991-09-01

    The purpose of this report is to document the results of the following task: Review for quality and consistency the available data on measurements of initial ground contamination of Chernobyl radionuclides in various parts of Norway and subsequent concentrations of these radionuclides in various environmental media as functions of time. Utilize the data obtained to verify the existing models, or to improve them, for describing radionuclide behavior in the environment. Some of the processes standard were: migration into soil; weathering; resuspension; food-chain contamination; and loss or reconcentration by run-off. The task performed within this contract has been to use post-Chernobyl data from Norway to verify or find areas for possible improvement in the chronic exposure pathway models utilized in MACCS. Work has consisted mainly of collecting and evaluating post-Chernobyl information from Norway or other countries when relevant; but has also included experimental work performed specifically for the current task. In most connections the data available show the models and data in MACCS to be appropriate. A few areas where the data indicate that the MACCS approach is faulty or inadequate are, however, pointed out in the report. These should be examined carefully, and appropriate modifications should eventually be made. 14 refs., 12 figs., 22 tabs

  7. Radionuclide daughter inventory generator code: DIG

    International Nuclear Information System (INIS)

    Fields, D.E.; Sharp, R.D.

    1985-09-01

    The Daughter Inventory Generator (DIG) code accepts a tabulation of radionuclide initially present in a waste stream, specified as amounts present either by mass or by activity, and produces a tabulation of radionuclides present after a user-specified elapsed time. This resultant radionuclide inventory characterizes wastes that have undergone daughter ingrowth during subsequent processes, such as leaching and transport, and includes daughter radionuclides that should be considered in these subsequent processes or for inclusion in a pollutant source term. Output of the DIG code also summarizes radionuclide decay constants. The DIG code was developed specifically to assist the user of the PRESTO-II methodology and code in preparing data sets and accounting for possible daughter ingrowth in wastes buried in shallow-land disposal areas. The DIG code is also useful in preparing data sets for the PRESTO-EPA code. Daughter ingrowth in buried radionuclides and in radionuclides that have been leached from the wastes and are undergoing hydrologic transport are considered, and the quantities of daughter radionuclide are calculated. Radionuclide decay constants generated by DIG and included in the DIG output are required in the PRESTO-II code input data set. The DIG accesses some subroutines written for use with the CRRIS system and accesses files containing radionuclide data compiled by D.C. Kocher. 11 refs

  8. Radionuclide migration test using undisturbed aerated soil

    International Nuclear Information System (INIS)

    Yamamoto, Tadatoshi; Ohtsuka, Yoshiro; Ogawa, Hiromichi; Wadachi, Yoshiki

    1988-01-01

    As one of the most important part of safety assessment on the shallow land disposal of lowlevel radioactive waste, the radionuclide migration was studied using undisturbed soil samples, in order to evaluate an exact radionuclide migration in an aerated soil layer. Soil samples used in the migration test were coastal sand and loamy soil which form typical surface soil layers in Japan. The aqueous solution containing 60 CoCl 2 , 85 SrCl 2 and 137 CsCl was fed into the soil column and concentration of each radionuclide both in effluent and in soil was measured. Large amount of radionuclides was adsorbed on the surface of soil column and small amount of radionuclides moved deep into the soil column. Difference in the radionuclide profile was observed in the low concentration portion particularly. It is that some fractions of 60 Co and 137 Cs are stable in non-ionic form and move downward through the soil column together with water. The radionuclide distribution in the surface of soil column can be fairly predicted with a conventional migration equation for ionic radionuclides. As a result of radionuclide adsorption, both aerated soil layers of coastal sand and loamy soil have large barrier ability on the radionuclide migration through the ground. (author)

  9. Metabolism of radionuclides in domestic animals

    International Nuclear Information System (INIS)

    Wirth, E.; Leising, C.

    1986-01-01

    The reactor accident at Chernobyl has shown that shortly after the contamination of the environment radionuclides can be found in animal products. The main contamination pathways of domestic animas are: uptake of radionuclides by foodstuffs; uptake of radionuclides by contaminated drinking water; uptake of radionuclides by inhalation; uptake of radionuclides through skin; uptake of radionuclides by ingestion of soil particles. Generally the uptake of radionuclides by food is the dominant exposure pathway. In rare cases the inhalation of radionuclides or the uptake by drinking water may be of importance. The metabolism of incorporated radionuclides is comparable to the respective metabolism of essential mass or trace elements or heavy metals. Radioisotopes of essential elements are for instance iron 55, manganese 54, cobalt 58 and cobalt 60. Other elements are typical antagonists to essential elements, e.g. strontium 90 is an antagonist to calcium or cesium 137 to potassium. Lead 210 and plutonium 239 behave similarly as heavy metals. Generally the knowledge of the metabolism of trace and mass elements, of antagonistic and synergistic elements and heavy metals can be applied to these radionuclides

  10. Radionuclide investigations in clinical cardiology - 10 years of cooperation in Frankfurt/FRG

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Kaltenbach, M.

    1989-01-01

    Radionuclide investigations today are an important tool in cardiology. They close the diagnostic gap in cases where non-invasive procedures of cardiological diagnosis such as ecg, exercise-ecg, echocardiography and chest-x-ray remains unrevealing. Further, they are helpful when an exact quantitation of the disease or a precise follow-up is required. Radionuclide techniques are very useful to detect myocardial ischemia in patients with coronary heart disease and to judge myocardial function in patients with aortic or mitral regurgitation. Follow-up investigations after therapy (aortocoronary bypass, PTCA, valve replacement) permit conclusions regarding the benefit of these measures. Results of radionuclide investigations should consider the Bayes' theorem in order to keep false-negative and false-positive reports as low as possible. (orig.) [de

  11. Report on the intercomparison run IAEA-306 radionuclides in Baltic Sea sediment

    International Nuclear Information System (INIS)

    Ballestra, S.; Vas, D.; Lopez, J.J.; Noshkin, V.

    1989-10-01

    The results of an intercomparison exercise on a Baltic Sea sediment sample, coded as IAEA-306, designed for the determination of artificial and natural radionuclide levels, are reported. This sample was collected in the fall 1986. It was anticipated that the concentrations of the artificial radionuclides in this sediment would be higher than the environmental levels usually found and, therefore, would constitute an excellent intercomparison sample. The data from 84 laboratories representing 34 countries have been evaluated. The most frequently measured radionuclides are: 90 Sr, 125 Sb, 134 Cs, 137 Cs, 238 Pu, 239+240 Pu, 241 Am, 40 K, 210 Pb- 210 Po, 226 Ra, 228 Ra, 228 Th, 230 Th, 232 Th, 234 U and 238 U. 6 refs, 13 tabs

  12. Review and assessment of models for predicting the migration of radionuclides through rivers

    International Nuclear Information System (INIS)

    Monte, Luigi; Boyer, Patrick; Brittain, John E.; Haakanson, Lars; Lepicard, Samuel; Smith, Jim T.

    2005-01-01

    The present paper summarises the results of the review and assessment of state-of-the-art models developed for predicting the migration of radionuclides through rivers. The different approaches of the models to predict the behaviour of radionuclides in lotic ecosystems are presented and compared. The models were classified and evaluated according to their main methodological approaches. The results of an exercise of model application to specific contamination scenarios aimed at assessing and comparing the model performances were described. A critical evaluation and analysis of the uncertainty of the models was carried out. The main factors influencing the inherent uncertainty of the models, such as the incompleteness of the actual knowledge and the intrinsic environmental and biological variability of the processes controlling the behaviour of radionuclides in rivers, are analysed

  13. Enhancement of the 1985 Browns Ferry exercise through the use of spiked samples

    International Nuclear Information System (INIS)

    McNees, J.L.

    1987-01-01

    The use of spiked environmental samples has proven to be a beneficial part of nuclear power plant exercises. Milk, soil, and air sampling cartridges can easily be spiked with realistic concentrations of radionuclide without violating Nuclear Regulatory Commission regulations or policy and with no significant radiation hazard to exercise participants. Analysis and reporting of data from realistic samples significantly improves motivation, attitude, moral, and overall preparedness of the individuals participating in that phase of the exercise

  14. Methods of separating short half-life radionuclides from a mixture of radionuclides

    Science.gov (United States)

    Bray, Lane A.; Ryan, Jack L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of .sup.223 Ra and .sup.225 Ac, from a radionuclide "cow" of .sup.227 Ac or .sup.229 Th respectively. The method comprises the steps of a) permitting ingrowth of at least one radionuclide daughter from said radionuclide "cow" forming an ingrown mixture; b) insuring that the ingrown mixture is a nitric acid ingrown mixture; c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the "cow" from at least one radionuclide daughter; d) insuring that the at least one radionuclide daughter contains the radionuclide product; e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and f) recycling the at least one radionuclide daughter by adding it to the "cow". In one embodiment the radionuclide "cow" is the .sup.227 Ac, the at least one daughter radionuclide is a .sup.227 Th and the product radionuclide is the .sup.223 Ra and the first nitrate form ion exchange column passes the .sup.227 Ac and retains the .sup.227 Th. In another embodiment the radionuclide "cow"is the .sup.229 Th, the at least one daughter radionuclide is a .sup.225 Ra and said product radionuclide is the .sup.225 Ac and the .sup.225 Ac and nitrate form ion exchange column retains the .sup.229 Th and passes the .sup.225 Ra/Ac.

  15. Relationship between normalization of negative T waves on exercise ECG and residual myocardial viability in patients with previous myocardial infarction and no post-infarction angina

    Energy Technology Data Exchange (ETDEWEB)

    Ajisaka, Ryuichi; Watanabe, Shigeyuki; Masuoka, Takeshi; Yamanouchi, Takayoshi; Saitoh, Takumi; Toyama, Masahiro; Takeda, Tohru; Itai, Yuji; Sugishita, Yasuro [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    1998-03-01

    The usefulness of normalization of negative T waves in exercise ECG was investigated as an index of myocardial viability in patients with previous myocardial infarction with no symptoms or ischemic ST-segment change during exercise test. A total of 39 patients, 20 with T-wave normalization (POS group) and 19 without T-wave normalization (NEG group) on exercise ECG, were studied. Myocardial viability was evaluated by thallium-201 single-photon emission computed tomography (SPECT) during exercise or at rest. We also assessed left ventricular ejection fraction (LVEF) by contrast ventriculography before (n=39) and after percutaneous transluminal coronary angioplasty (PTCA) (n=17). SPECT detected myocardial viability in 16 (80%) of the 20 patients in the POS group and in 4 (21%) of the 19 patients in the NEG group (p<0.01). LVEF increased after successful PTCA in the POS group (from 53{+-}13% to 63{+-}8%, p<0.025), but fell in the NEG group (from 57{+-}10% to 51{+-}8%). It is concluded that normalization of negative T waves on exercise ECG is a useful, simple index of myocardial viability in patients with previous myocardial infarction with no symptoms or ischemic ST-segment change during exercise testing. (author)

  16. Mitral valve prolapse in the ventriculogram: scintigraphic, electrocardiographic, and hemodynamic abnormalities

    International Nuclear Information System (INIS)

    Tebbe, U.; Schicha, H.; Neumann, P.; Voth, E.; Emrich, D.; Neuhaus, K.L.; Kreuzer, H.

    1985-01-01

    Patients with mitral valve prolapse (MVP) frequently have chest pain, which may be difficult to differentiate from angina pectoris in coronary artery disease (CAD). The authors performed resting and exercise ECGs, pulmonary arterial pressure measurements, radionuclide ventriculography (/sup 99m/technetium), and perfusion scintigrams ( 201 thallium) in 56 patients with angiographically proven MVP and no CAD. Pathological results were obtained in 31% of exercise ECGs, 33% of pulmonary arterial pressure measurements during exercise, 22% of radionuclide ventriculographies, and in 75% of thallium perfusion scintigrams. A significant correlation in pathological results was found only between exercise ECG and both radionuclide ventriculography and pulmonary arterial pressure measurements. Because of the high prevalence of false-positive perfusion scintigrams in patients with typical or atypical chest pain, the use of exercise 201 Tl imaging as a screening method to separate patients with MVP from those with CAD will not be appropriate. The variability of cardiac abnormalities in our patients with MVP and angiographically normal coronary arteries suggests that the MVP syndrome may represent a variable combination of metabolic, ischemic, or myopathic disorders

  17. Performance and quality control of radionuclide calibrators in nuclear medicine

    International Nuclear Information System (INIS)

    Woods, M.J.; Baker, M.

    2002-01-01

    operators can be determined by the conduct of comparison exercises by expert and impartial laboratories. Such exercises can also have the added advantage of enabling the calibration of particular calibrators to be checked and even determined more accurately. A regular programme of such comparisons has been organised in the United Kingdom by the National Physical Laboratory (NPL) over the last fifteen to twenty years and follow-up workshops have been held for the participants to discuss the results and the potential avenues to performance improvements. The outputs from these comparisons, supplemented by regular dialogues and exchanges of information and experiences between the NPL and the user community, have identified a number of potential sources of error. In addition, the NPL, together with the relevant professional organisation in the UK, produced a quality assurance protocol in 1992, designed to establish and maintain the calibration of medical radionuclide calibrators and their quality control. That protocol is currently being revised to take into account both the increased emphasis on uncertainty estimation, the accumulation of comparison data and user experiences and the changes in equipment formats. This paper presents and discusses the results of the various comparisons conducted by NPL, particularly as they relate to the potential improvements in performance that can be achieved, and the developments in the recommended quality assurance protocol. It also addresses the developments of calibration facilities available with these systems, especially as they relate to the measurement of, and achievable accuracies for, therapeutic radiation sources. (author)

  18. Phytoremediation of radionuclides: an emerging alternative

    International Nuclear Information System (INIS)

    Singh, Shraddha

    2013-01-01

    Proliferation of nuclear power industry, nuclear weapon testing, dismantling of existing nuclear weapons and occasional accidents have contributed to an enhancement in the level of radionuclides in the environment. The radionuclides due to their long half life and transfer through the food chain effect adversely to normal biological systems. Hence, it is essential to effectively remove the radionuclides from contaminated soils and solutions. Phytoremediation - the use of plants for remediation of toxic metals and radionuclides has been recognized as an aesthetically pleasing, low cost and environment friendly in situ method. Phytoremediation is an umbrella term which covers several plant based approaches. Plants have shown the potential of remediation of these radionuclides from spiked solutions, low level nuclear waste and soil. Various aspects of phytoremediation as well as potential of various plants for remediation of radionuclides will be discussed here. (author)

  19. Radionuclide transport processes in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Whicker, F.W.

    1983-01-01

    Some major principles and the status of knowledge concerning the transport of radionuclides through terrestrial ecosystems are reviewed. Fundamental processes which control the flow of radionuclides between ecosystem components such as air, soil, plants, and animals are described, with emphasis on deposition, resuspension, plant uptake, ingestion, and assimilation. Properties of radionuclides, organisms, and ecosystems are examined in relation to their influence on the accumulation of radioactive materials by plants and animals. The effects of the physicochemical nature of the radionuclide; morphology, physiology, and behavior of the organism; and soil, nutrient, and trophic characteristics of the ecosystem are highlighted. Observations in natural ecosystems on radionuclides such as 137 Cs, 90 Sr, 131 I, 3 H, and 239 Pu are used to illustrate current concepts. An assessment of the degree to which the processes controlling radionuclide behavior are understood and of our ability to simulate and predict such behavior with computerized models is offered. Finally, brief comments are made on research needs

  20. Radionuclides in the study of marine processes

    International Nuclear Information System (INIS)

    Kershaw, P.J.; Woodhead, D.S.

    1991-01-01

    For many years, the radioactive properties of the naturally occurring radionuclides have been used to determine their distributions in the marine environment and, more generally, to gain an understanding of the dynamic processes which control their behaviour in attaining these distributions. More recently the inputs from human activities of both natural and artificial (i.e. man-made) radionuclides have provided additional opportunities for the study of marine processes on local, regional and global scales. The primary objective of the symposium is to provide a forum for an open discussion of the insights concerning processes in the marine environment which can be gained from studies of radionuclide behaviour. Papers have been grouped within the following principal themes; the uses of radionuclides as tracers of water transport; scavenging and particulate transport processes in the oceans as deduced from radionuclide behaviour; processes in the seabed and radionuclides in biological systems. (Author)

  1. Chemical speciation of radionuclides migrating in groundwaters

    International Nuclear Information System (INIS)

    Robertson, D.; Schilk, A.; Abel, K.; Lepel, E.; Thomas, C.; Pratt, S.; Cooper, E.; Hartwig, P.; Killey, R.

    1994-04-01

    In order to more accurately predict the rates and mechanisms of radionuclide migration from low-level waste disposal facilities via groundwater transport, ongoing studies are being conducted at field sites at Chalk River Laboratories to identify and characterize the chemical speciation of mobile, long-lived radionuclides migrating in groundwaters. Large-volume water sampling techniques are being utilized to separate and concentrate radionuclides into particular, cationic, anionic, and nonionic chemical forms. Most radionuclides are migrating as soluble, anionic species that appear to be predominantly organoradionuclide complexes. Laboratory studies utilizing anion exchange chromatography have separated several anionically complexed radionuclides, e.g., 60 Co and 106 Ru, into a number of specific compounds or groups of compounds. Further identification of the anionic organoradionuclide complexes is planned utilizing high resolution mass spectrometry. Large-volume ultra-filtration experiments are characterizing the particulate forms of radionuclides being transported in these groundwaters

  2. Production of radionuclides with generators

    International Nuclear Information System (INIS)

    Khujaev, S.; Egamediev, S.Kh.

    2004-01-01

    Full text: The radionuclide generator provides a convenient means for researchers and clinicians to obtain a source of radionuclides without dependence on nuclear facilities (nuclear reactor or cyclotron). It should be noted that radionuclide generator technique yields products of very high purity and it offers moreover the only possible way of obtaining very short-lived radionuclides for practical applications. Therefore at present radionuclide generators have found important uses in nuclear medicine. This talk reviews the development of preparation methods for radionuclide generators of current interest: 99 Mo- 99m Tc, 188 W- 188 Re and 68 Ge- 68 Ga. 99 Mo- 99m Tc generator. 99m Tc is presently the most widely used radionuclide in diagnostic nuclear medicine. The reason for such a preeminent position of 99m Tc in clinical uses is its extremely favorable nuclear properties with γ-energy of 140 keV and short half-life of 6 hours. Chromatographic generator of 99 Mo- 99m Tc based on aluminium oxide using as eluent of isotonic saline solution, containing nitrate-ions has been produced in INP AS RU. However, the main disadvantage of this generator is that the eluent-saline solution contains some amount of nitrate-ions. Nitrate-ions added to maximize and stabilize 99m Tc yields would interfere with the chemical reactions which involve Sn(II) reduction of the pertechnetate ion and which are used subsequently in the preparation of radiopharmaceuticals. Therefore we proposed the new method for preliminary treatment of aluminium oxide by the external gamma (Co-60) irradiation. It is found that the aluminium oxide has got electron-acceptor properties after gamma-irradiation. Adsorption of 99 Mo radionuclide as isopolymolybdate on gamma-irradiated aluminium oxide is very high and molybdenum is firmly retained. Adsorption capacity of gamma-irradiated aluminium oxide at pH 2-4 is 60-80 mg Mo per gram of Al 2 O 3 . The yields of 99m Tc from experimental generators remained high

  3. Exercise at Home

    Science.gov (United States)

    ... Home Health Insights Exercise & Weight Exercise at Home Exercise at Home Make an Appointment Ask a Question ... with the movement and contact your provider. Posture Exercises Better posture means better breathing and movement. Axial ...

  4. DKPRO: A radionuclide decay and reprocessing code

    International Nuclear Information System (INIS)

    Wootan, D.; Schmittroth, F.A.

    1997-01-01

    The DKPRO code solves the general problem of modeling complex nuclear wastes streams using ORIGEN2 radionuclide production files. There is a continuing need for estimates of Hanford radionuclides. Physical measurements are one basis; calculational estimates, the approach represented here, are another. Given a known nuclear fuel history, it is relatively straightforward to calculate radionuclide inventories with codes such as the widely-used Oak Ridge National Laboratory code ORIGEN2

  5. Radionuclide usage survey 1979-80

    International Nuclear Information System (INIS)

    Woods, M.J.

    1980-08-01

    Details of a survey by the Life Sciences Working Group of the International Committee for Radionuclide Metrology (ICRM) on radionuclide usage by medical physicists in 11 countries are presented. The results indicate that the radionuclide which will be of most significance in the future will be F-18, Fe-52, Ga-67, Ga-68, Kr-81m, Tc-99m, In-111, I-123, Xe-127 and Tl-201, (U.K.)

  6. Preparation of porous materials for radionuclides capture

    International Nuclear Information System (INIS)

    Bajzikova, Anna; Smrcek, Stanislav; Kozempel, Jan; Vlk, Martin; Barta, Jan

    2015-01-01

    Porous materials showing promise for radionuclide capture from water at contaminated sites were prepared. Nanoporous materials (size of pores 1-100 nm) and some polymers are well suited to this purpose owing their affinity for selected radionuclides. Nanoporous metal oxides and silica gel with styrene-divinylbenzene-TODGA-modified surface were prepared, characterized and tested for radionuclide ( 227 Ac, 227 Th, 223 Ra) capture efficiency. (orig.)

  7. Prevention: Exercise

    Medline Plus

    Full Text Available ... abdominal wall inward, exhale as you lift chest area. This can be done with quick short movements, or slow full movements. Repeat 10-15 times, to fatigue... Abdominal Exercise Lay on your back with both knees ... © 2018 North ...

  8. Prevention: Exercise

    Medline Plus

    Full Text Available ... 10 Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! Stretching/Flexibility Aerobic ... Strength Training for the Elderly Other Back Pack Safety Pregnancy and Back ... Patient Information Feature Articles Patient Q&A Success Stories ...

  9. Evacuation exercise

    CERN Multimedia

    AUTHOR|(CDS)2094367

    2017-01-01

    In the event of an emergency, it is important that staff and visitors are evacuated safely and efficiently. Hence CERN organises regularly emergency response and evacuation exercise (also known as an ‘evacuation drill’) in different buildings across the sites.

  10. Compulsive Exercise

    Science.gov (United States)

    ... compulsive habit when it is done for the wrong reasons. Some people start exercising with weight loss as their main ... developing normally. This is especially true if the person also has an eating disorder. Girls who overexercise and restrict their eating ...

  11. Prevention: Exercise

    Medline Plus

    Full Text Available ... Information Feature Articles Patient Q&A Success Stories Definitions Anatomy of the Spine Definitions A-Z Spine Specialists Videos 9 for Spine Epidural Steroid Injections Exercise: The Backbone of Spine Treatment Spondylolisthesis BLOG FIND A SPECIALIST Prevention ...

  12. Why Exercise?

    Science.gov (United States)

    ... strength, boosts energy, and can help you reduce stress. It can also help you maintain a healthy body weight and curb ... well-being and help treat depression. Help relieve stress and anxiety. Increase ... Can anyone exercise? Everyone can benefit from physical activity. ...

  13. Prevention: Exercise

    Medline Plus

    Full Text Available ... Feature Articles Patient Q&A Success Stories Definitions Anatomy of the Spine Definitions A-Z Spine ... Strengthening Many popular forms of exercise focus on core strengthening, or building the muscles that provide support for your body. Pilates, yoga ...

  14. Environmental behaviour of radionuclides and transfer to man

    International Nuclear Information System (INIS)

    Smith, H.

    1982-01-01

    The environmental behaviour of the radionuclides making the major contribution to man's irradiation through diet is described. The following stages are emphasized: transfer of radionuclides to plants; transfer of radionuclides to animals; metabolism of inhaled or ingested radionuclides in animals providing food for man; transfer of radionuclides through the aquatic environment; application of food chain models. (43 references)

  15. Radionuclide accumulation peculiarities demonstrated by vegetable varieties

    International Nuclear Information System (INIS)

    Kruk, A.V.; Goncharenko, G.G.; Kilchevsky, A.V.

    2004-01-01

    This study focused on ecological and genetic aspects of radionuclide accumulation demonstrated by a number of vegetable varieties. The researches resulted in determining the cabbage varieties which were characterised by the minimal level of radionuclide accumulation. It was shown that the above varieties manifested the relation between radionuclide accumulation and morphobiological characteristics such as vegetation period duration and yield criteria. The study specified the genotypes with high ecological stability as regards to radionuclide accumulation: 'Beloruskaya 85' cabbage and 'Dokhodny' tomato showed the best response to Cs 137, while 'Beloruskaya 85', 'Rusinovka', 'Amager 611' cabbage varieties and 'Sprint' tomato showed the minimal level of Sr 90 accumulation. (authors)

  16. Therapy for incorporated radionuclides: scope and need

    International Nuclear Information System (INIS)

    Smith, V.H.

    1981-03-01

    In the United States the recent termination of funding for research on therapy for incorporated radionuclides has virtually halted progress on improved or new agents and procedures for removing radioactivity from the body. Research was eliminated, but is still needed on new removal agents, improved delivery system, in vitro test systems, and the toxicology of treatments. For many radionuclides, no adequate therapy exists. The relationship between radionuclide removal and reduction in cancer risk is still unanswered. Without proper research support, needed improvements in the treatment for incorporated radionuclides in the US are uncertain

  17. Exercise Hypertension.

    Science.gov (United States)

    Schultz, Martin G; Sharman, James E

    2014-05-01

    Irrespective of apparent 'normal' resting blood pressure (BP), some individuals may experience an excessive elevation in BP with exercise (i.e. systolic BP ≥210 mm Hg in men or ≥190 mm Hg in women or diastolic BP ≥110 mm Hg in men or women), a condition termed exercise hypertension or a 'hypertensive response to exercise' (HRE). An HRE is a relatively common condition that is identified during standard exercise stress testing; however, due to a lack of information with respect to the clinical ramifications of an HRE, little value is usually placed on such a finding. In this review, we discuss both the clinical importance and underlying physiological contributors of exercise hypertension. Indeed, an HRE is associated with an increased propensity for target organ damage and also predicts the future development of hypertension, cardiovascular events and mortality, independent of resting BP. Moreover, recent work has highlighted that some of the elevated cardiovascular risks associated with an HRE may be related to high-normal resting BP (pre-hypertension) or ambulatory 'masked' hypertension and that an HRE may be an early warning signal of abnormal BP control that is otherwise undetected with clinic BP. Whilst an HRE may be amenable to treatment via pharmacological and lifestyle interventions, the exact physiological mechanism of an HRE remains elusive, but it is likely a manifestation of multiple factors including large artery stiffness, increased peripheral resistance, neural circulatory control and metabolic irregularity. Future research focus may be directed towards determining threshold values to denote the increased risk associated with an HRE and further resolution of the underlying physiological factors involved in the pathogenesis of an HRE.

  18. Radionuclide transport through heteogeneous media

    International Nuclear Information System (INIS)

    Hadermann, J.

    1980-01-01

    One-dimensional radionuclide migration for conevective water transport with sorption and longitudinal dispersion is investigated. A semianalytic solution for layered media with piecewise constant parametes can be written when taking into account mass conservation and approximate flux conservation at interlayer boundaries. The solution is analytic in the first layer and allows for a recursive calculation in the following layers. Scaling laws for the relevant parameters can be formulated. Numerical examples exhibit the importance of at least a single highly sorbing layer. Small values of dispersivity may not lead to a conservative estimate of conservation at the geological column's end

  19. Radionuclide transfer to meadow vegetation

    International Nuclear Information System (INIS)

    Goncharova, N.; Matsko, N.; Zhebrakova, I.; Montik, T.

    1999-01-01

    In the paper results of radioecological monitoring of natural plant populations in the 30 km zone of the Chernobyl Nuclear Power Plant (Polesky State Radioecological Reserve) during the period from 1987 to 1998 are presented. The level of radiation background in experimental areas varied from 0.1 to 30 mR/h that correspond to the total soil activity of 300-24000 kBq/m 2 (for May 1997). Monitoring was carried out including the radionuclide migration in natural plant complexes and transfer of 137 Cs between some plant organs. Refs. 3 (author)

  20. Dosimetry of incorporated transuranic radionuclides

    International Nuclear Information System (INIS)

    Loessner, V.

    1983-01-01

    Modern in vivo and in vitro techniques for detecting transuranic radionuclides within the human body are described with special emphasis on multiparameter measuring methods developed at the National Board of Nuclear Safety and Radiation Protection. Furthermore, problems related to calibration and interpretation of measuring data are discussed and new methods presented for the calculation of committed dose equivalents on the basis of data from ICRP Publication 30. Also included is an introductory chapter on radiobiological fundamentals of intake, translocation and metabolism of these nuclides. (author)

  1. Dietary intake of natural radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Smith-Briggs, J L; Bradley, E J [National Radiological Protection Board, Chilton (UK)

    1984-09-01

    The levels of the natural radionuclides, radium-226, lead-210 and polonium-210 were measured in food samples collected for a National Food Survey, thus reflecting current consumption patterns in the UK. Daily intakes of radium-226, lead-210 and inferred values of polonium-210 were calculated for 20 food groups. From these data, the annual effective dose equivalents from radium-226, lead-210 and polonium-210 in the UK diet were estimated to be 3..mu..Sv, 41..mu..Sv and 13..mu..Sv respectively.

  2. Dietary intake of natural radionuclides

    International Nuclear Information System (INIS)

    Smith-Briggs, J.L.; Bradley, E.J.

    1984-01-01

    The levels of the natural radionuclides, radium-226, lead-210 and polonium-210 were measured in food samples collected for a National Food Survey, thus reflecting current consumption patterns in the UK. Daily intakes of radium-226, lead-210 and inferred values of polonium-210 were calculated for 20 food groups. From these data, the annual effective dose equivalents from radium-226, lead-210 and polonium-210 in the UK diet were estimated to be 3μSv, 41μSv and 13μSv respectively. (U.K.)

  3. Exercise testing and hemodynamic performance in healthy elderly persons

    International Nuclear Information System (INIS)

    Hitzhusen, J.C.; Hickler, R.B.; Alpert, J.S.; Doherty, P.W.

    1984-01-01

    To determine the effect of age on cardiovascular performance, 39 healthy elderly men and women, 70 to 83 years old, underwent treadmill thallium-201 exercise perfusion imaging and radionuclide equilibrium angiography at rest and during supine bicycle exercise. Five volunteers who had a positive exercise thallium test response were excluded from the study. Radionuclide left ventricular ejection fraction, regional wall abnormalities, relative cardiac output, stroke volume, end-diastolic volume and end-systolic volume were measured. Seventy-four percent of the subjects maintained or increased their ejection fraction with exercise. With peak exercise, mean end-diastolic volume did not change, end-systolic volume decreased and cardiac output and stroke volume increased. Moreover, in 35% of the subjects, minor regional wall motion abnormalities developed during exercise. There was no significant difference in the response of men and women with regard to these variables. However, more women than men had difficulty performing bicycle ergometry because they had never bicycled before. Subjects who walked daily performed the exercise tests with less anxiety and with a smaller increase in heart rate and systolic blood pressure

  4. Mathematical Basis and Test Cases for Colloid-Facilitated Radionuclide Transport Modeling in GDSA-PFLOTRAN

    Energy Technology Data Exchange (ETDEWEB)

    Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-31

    This report provides documentation of the mathematical basis for a colloid-facilitated radionuclide transport modeling capability that can be incorporated into GDSA-PFLOTRAN. It also provides numerous test cases against which the modeling capability can be benchmarked once the model is implemented numerically in GDSA-PFLOTRAN. The test cases were run using a 1-D numerical model developed by the author, and the inputs and outputs from the 1-D model are provided in an electronic spreadsheet supplement to this report so that all cases can be reproduced in GDSA-PFLOTRAN, and the outputs can be directly compared with the 1-D model. The cases include examples of all potential scenarios in which colloid-facilitated transport could result in the accelerated transport of a radionuclide relative to its transport in the absence of colloids. Although it cannot be claimed that all the model features that are described in the mathematical basis were rigorously exercised in the test cases, the goal was to test the features that matter the most for colloid-facilitated transport; i.e., slow desorption of radionuclides from colloids, slow filtration of colloids, and equilibrium radionuclide partitioning to colloids that is strongly favored over partitioning to immobile surfaces, resulting in a substantial fraction of radionuclide mass being associated with mobile colloids.

  5. Determination of radionuclide solubility limits to be used in SR 97. Uncertainties associated to calculated solubilities

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J.; Cera, E.; Duro, L.; Jordana, S. [QuantiSci S.L., Barcelona (Spain); Pablo, J. de [DEQ-UPC, Barcelona (Spain); Savage, D. [QuantiSci Ltd., Henley-on-Thames (United Kingdom)

    1997-12-01

    The thermochemical behaviour of 24 critical radionuclides for the forthcoming SR97 PA exercise is discussed. The available databases are reviewed and updated with new data and an extended database for aqueous and solid species of the radionuclides of interest is proposed. We have calculated solubility limits for the radionuclides of interest under different groundwater compositions. A sensitivity analysis of the calculated solubilities with the composition of the groundwater is presented. Besides selecting the most likely solubility limiting phases, in this work we have used coprecipitation approaches in order to calculate more realistic solubility limits for minor radionuclides, such as Ra, Am and Cm. The comparison between the calculated solubilities and the concentrations measured in relevant natural systems (NA) and in spent fuel leaching experiments helps to assess the validity of the methodology used and to derive source term concentrations for the radionuclides studied. The uncertainties associated to the solubilities of the main radionuclides involved in the spent nuclear fuel have also been discussed in this work. The variability of the groundwater chemistry; redox conditions and temperature of the system have been considered the main factors affecting the solubilities. In this case, a sensitivity analysis has been performed in order to study solubility changes as a function of these parameters. The uncertainties have been calculated by including the values found in a major extent in typical granitic groundwaters. The results obtained from this analysis indicate that there are some radionuclides which are not affected by these parameters, i.e. Ag, Cm, Ho, Nb, Ni, Np, Pu, Se, Sm, Sn, Sr, Tc and U

  6. Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Acampa, Wanda; Liuzzi, Raffaele; De Luca, Serena; Capasso, Enza; Luongo, Luca; Cuocolo, Alberto; Caprio, Maria Grazia; Nicolai, Emanuele; Petretta, Mario

    2010-01-01

    We compared left ventricular (LV) ejection fraction obtained by gated SPECT with that obtained by equilibrium radionuclide angiocardiography in a large cohort of patients. Within 1 week, 514 subjects with suspected or known coronary artery disease underwent same-day stress-rest 99m Tc-sestamibi gated SPECT and radionuclide angiocardiography. For both studies, data were acquired 30 min after completion of exercise and after 3 h rest. In the overall study population, a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.82, p<0.0001) and after stress (r=0.83, p<0.0001). In Bland-Altman analysis, the mean differences in ejection fraction (radionuclide angiocardiography minus gated SPECT) were -0.6% at rest and 1.7% after stress. In subjects with normal perfusion (n=362), a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.72, p<0.0001) and after stress (r=0.70, p<0.0001) and the mean differences in ejection fraction were -0.9% at rest and 1.4% after stress. Also in patients with abnormal perfusion (n=152), a good correlation between the two techniques was observed both at rest (r=0.89, p<0.0001) and after stress (r=0.90, p<0.0001) and the mean differences in ejection fraction were 0.1% at rest and 2.5% after stress. In a large study population, a good agreement was observed in the evaluation of LV ejection fraction between gated SPECT and radionuclide angiocardiography. However, in patients with perfusion abnormalities, a slight underestimation in poststress LV ejection fraction was observed using gated SPECT as compared to equilibrium radionuclide angiocardiography. (orig.)

  7. Radionuclide behavior at underground environment

    International Nuclear Information System (INIS)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Park, Hyun Soo

    2003-04-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. This project is composed of 6 subjects such as data production required for safety assessments, sorption properties and mechanisms, nuclide migration in the fractured rock, colloid formation and migration, nuclide speciation in deep geological environments, and total evaluation of geochemical behaviors considering multi-factors. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal

  8. Miscellaneous applications of radionuclide imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.; Freeman, L.M.

    1984-01-01

    The procedures discussed in this chapter are either developmental, in limited clinical use, or frankly moribund. A number of radionuclide imaging techniques have proved disappointing when approached from a purely anatomic point of view. This is particularly evident to our colleagues with the explosive growth of the noninvasive imaging procedures, magnetic resonance imaging (NMR), CT, and ultrasound, and the introduction of the less invasive digital radiographic approach to vascular opacification, all of which are capable of providing exquisite anatomic or tissue detail beyond the reach of current or reasonably priced nuclear medicine imaging systems. Yet, most nuclear medicine procedures possess the unique advantage of portraying a physiologic function without interfering with that function. Moreover, the procedures can be employed under conditions of stress, which are likely to bring out pathophysiologic abnormalities that remain masked when unchallenged. Information concerning form without functional data has less meaning than both together. The physiologic information inherent in nuclear medicine imaging may often provide not only key diagnostic information but also illuminate a therapeutic trail. Yet, it is often slighted in favor of the anatomic quest. While mastery of the nuances of imaging details remains critical, radionuclide image interpretation must rest upon a firm physiologic foundation. For this reason, this chapter emphasizes the physiologic approach

  9. Stochastic approach for radionuclides quantification

    Science.gov (United States)

    Clement, A.; Saurel, N.; Perrin, G.

    2018-01-01

    Gamma spectrometry is a passive non-destructive assay used to quantify radionuclides present in more or less complex objects. Basic methods using empirical calibration with a standard in order to quantify the activity of nuclear materials by determining the calibration coefficient are useless on non-reproducible, complex and single nuclear objects such as waste packages. Package specifications as composition or geometry change from one package to another and involve a high variability of objects. Current quantification process uses numerical modelling of the measured scene with few available data such as geometry or composition. These data are density, material, screen, geometric shape, matrix composition, matrix and source distribution. Some of them are strongly dependent on package data knowledge and operator backgrounds. The French Commissariat à l'Energie Atomique (CEA) is developing a new methodology to quantify nuclear materials in waste packages and waste drums without operator adjustment and internal package configuration knowledge. This method suggests combining a global stochastic approach which uses, among others, surrogate models available to simulate the gamma attenuation behaviour, a Bayesian approach which considers conditional probability densities of problem inputs, and Markov Chains Monte Carlo algorithms (MCMC) which solve inverse problems, with gamma ray emission radionuclide spectrum, and outside dimensions of interest objects. The methodology is testing to quantify actinide activity in different kind of matrix, composition, and configuration of sources standard in terms of actinide masses, locations and distributions. Activity uncertainties are taken into account by this adjustment methodology.

  10. Infusion of radionuclides throughout pregnancy

    International Nuclear Information System (INIS)

    Mountford-Lister, P.G.; Lambert, B.E.; Milner, A.C.; Kang, X.Z.

    1992-01-01

    This work is part of a long-term study to examine the cancer incidence in the offspring of mice exposed to 239 Pu or 147 Pm throughout pregnancy. The need to model the human intake scenario and the possibility of a critical period during uterine development necessitates constant availability of radionuclides throughout pregnancy. Various methods (multiple daily injections, infusion by external cannula and infusion by indwelling osmotic pump) have been examined and osmotic infusion pumps chosen. These pumps result in a near-constant blood concentration for up to 21 days. Part of the study is the estimation of dose to the critical haemopoietic tissues of the pup from a knowledge of the radionuclide distribution and kinetics. At present the distribution has been followed from birth to 180 days. Activity in the suckling pups at 7 days old is around 1 percent of the infused activity, though most of this is accounted for by the contents of the stomach and gastrointestinal tract. The liver and femur account for around 0.025 percent and 0.012 percent respectively per pup. Activity increases in both liver and femur during lactation after which both concentration and activity fall with time. Long-term studies with the pups of dams exposed to a range of 239 Pu concentrations between 0-70 kBq/kg are underway. Correlation of average organ dose with tumour incidence will be determined at completion of the life-span study. (Author) 39 refs., 5 tabs., 6 figs

  11. Sedimentary Processes. Quantification Using Radionuclides

    International Nuclear Information System (INIS)

    Carroll, J.; Lerche, I.

    2003-01-01

    The advent of radionuclide methods in geochronology has revolutionized our understanding of modern sedimentary processes in aquatic systems. This book examines the principles of the method and its use as a quantitative tool in marine geology, with emphasis on the Pb-210 method. The assumptions and consequences of models and their behaviour are described providing the necessary background to assess the advantages and trade-offs involved when choosing a particular model for application. One of the purposes of this volume is to disentangle the influences of complicating factors, such as sediment flux variations, post-depositional diffusion of radionuclides, and bio-irrigation of sediments, to arrive at sediment ages and to properly assess the attendant data uncertainty. Environmental impacts of chemical, nuclear, or other waste material are of concern in a variety of areas around the world today. A number of relevant examples are included, demonstrating how dating models are useful for determining sources of contaminants and interpreting their influence on the environment. The book is set at a level so that an able student or professional should have no difficulty in following the procedures and methods developed. Each chapter includes case histories showing the strengths and weaknesses of a given procedure with respect to a data example. Included with this volume is the computer source code of a new generation of modelling tools based on inverse numerical analysis techniques. This first generation of the modelling tool is included, along with detailed instructions and examples for its use, in an appendix

  12. Radionuclide transit in esophageal varices

    International Nuclear Information System (INIS)

    Yeh, S.H.; Wang, S.J.; Wu, L.C.; Liu, R.S.; Tsai, Y.T.; Chiang, T.T.

    1985-01-01

    This study assessed esophageal motility in patients with esophageal varices by radionuclide transit studies. Data were acquired in list mode after an oral dose of 0.5 mCi Tc-99m sulfur colloid in 10 ml of water in the supine position above a low-energy all-purpose collimator of a gamma camera. The condensed image (CI) superimposed with a centroid curve was also produced in each case. Twenty-five normal subjects (N) and 32 patients (pts) with esophageal varices by endoscopy (large varices in Grades IV and V in 8 and small varices in Grade III or less in 24) were studied. TMTT, RTT, RF, and RI were all significantly increased in pts as compared to N. Especially, the transit time for the middle third (6.7 +- 2.6 sec vs 3.5 +- 0.9 sec in N, rho < 0.005) had the optimal sensitivy and specificity of 88% each at the cutoff value of 4.2 sec as determined by ROC analysis. In summary, radionuclide transit disorders occur in the majority of pts with esopageal varices. The middle RTT and CI are both optimal in sensitivity and specificity for detecting the abnormalities

  13. Radionuclide analysis of bush food

    International Nuclear Information System (INIS)

    Koperski, J.; Bywater, J.

    1985-01-01

    A model diet for an Aboriginal adult living entirely on bush foods collected from the Alligator Rivers Region of the Northern Territory has been established. Results of investigations of the specific activities of thorium-230, radium-226, lead-210 and polonium-210 in 123 samples of bush foods collected by Ranger Uranium Mines Pty Ltd during pre-production and production periods are presented. For all the investigated bush food items, excluding freshwater mussels (Velesunio angasi), no systematic differences were found between the specific activities of the radionuclides monitored in food items sampled during preproduction and production periods. Preliminary estimates of annual effective dose equivalent (DE) rates for stochastic effects on an adult living entirely on the model bush diet are presented. Of the four radionuclides monitored the major contributor to the effective DE rates appears to be lead-210 followed by radium-226. Among the selected nine components of the diet the major contributor to the effective DE rates appear to be mussels, water lilies and fish

  14. Radionuclide analysis of bush food

    Energy Technology Data Exchange (ETDEWEB)

    Koperski, J; Bywater, J [Ranger Uranium Mines Proprietary Ltd., Chatswood (Australia)

    1985-04-01

    A model diet for an Aboriginal adult living entirely on bush foods collected from the Alligator Rivers Region of the Northern Territory has been established. Results of investigations of the specific activities of thorium-230, radium-226, lead-210 and polonium-210 in 123 samples of bush foods collected by Ranger Uranium Mines Pty. Ltd. during pre-production and production periods are presented. For all the investigated bush food items, excluding freshwater mussels (Velesunio angasi), no systematic differences were found between the specific activities of the radionuclides monitored in food items sampled during preproduction and production periods. Preliminary estimates of annual effective dose equivalent (DE) rates for stochastic effects on an adult living entirely on the model bush diet are presented. Of the four radionuclides monitored the major contributor to the effective DE rates appears to be lead-210 followed by radium-226. Among the selected nine components of the diet the major contributor to the effective DE rates appear to be mussels, water lilies and fish.

  15. Eccentric exercise

    DEFF Research Database (Denmark)

    Kjaer, Michael; Heinemeier, Katja Maria

    2014-01-01

    to differences in type and/or amount of mechanical stimulus with regard to expression of collagen, regulatory factors for collagen, and cross-link regulators. In overused (tendinopathic) human tendon, eccentric exercise training has a beneficial effect, but the mechanism by which this is elicited is unknown......Eccentric exercise can influence tendon mechanical properties and matrix protein synthesis. mRNA for collagen and regulatory factors thereof are upregulated in animal tendons, independent of muscular contraction type, supporting the view that tendon, compared with skeletal muscle, is less sensitive......, and slow concentric loading appears to have similar beneficial effects. It may be that tendinopathic regions, as long as they are subjected to a certain magnitude of load at a slow speed, independent of whether this is eccentric or concentric in nature, can reestablish their normal tendon fibril alignment...

  16. Exercise testing in asymptomatic or minimally symptomatic aortic regurgitation: relationship of left ventricular ejection fraction to left ventricular filling pressure during exercise

    International Nuclear Information System (INIS)

    Boucher, C.A.; Wilson, R.A.; Kanarek, D.J.; Hutter, A.M. Jr.; Okada, R.D.; Liberthson, R.R.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Exercise radionuclide angiography is being used to evaluate left ventricular function in patients with aortic regurgitation. Ejection fraction is the most common variable analyzed. To better understand the rest and exercise ejection fraction in this setting, 20 patients with asymptomatic or minimally symptomatic severe aortic regurgitation were studied. All underwent simultaneous supine exercise radionuclide angiography and pulmonary gas exchange measurement and underwent rest and exercise measurement of pulmonary artery wedge pressure (PAWP) during cardiac catheterization. Eight patients had a peak exercise PAWP less than 15 mm Hg (group 1) and 12 had a peak exercise PAWP greater than or equal to 15 mm Hg (group 2). Group 1 patients were younger and more were in New York Heart Association class I. The two groups had similar cardiothoracic ratios, changes in ejection fractions with exercise, and rest and exercise regurgitant indexes. Using multiple regression analysis, the best correlate of the exercise PAWP was peak oxygen uptake (r . -0.78, p less than 0.01). No other measurement added significantly to the regression. When peak oxygen uptake was excluded, rest and exercise ejection fraction also correlated significantly (r . -0.62 and r . -0.60, respectively, p less than 0.01). Patients with asymptomatic or minimally symptomatic severe aortic regurgitation have a wide spectrum of cardiac performance in terms of the PAWP during exercise. The absolute rest and exercise ejection fraction and the level of exercise achieved are noninvasive variables that correlate with exercise PAWP in aortic regurgitation, but the change in ejection fraction with exercise by itself is not

  17. Radioisotope heart examination during exercise to diagnose ischemic heart disease

    International Nuclear Information System (INIS)

    Farsky, S.

    1986-01-01

    The radioisotope exercise test is discussed and its benefits characterized for the diagnosis of ischemic heart disease, namely the use of 99m Tc in scintiscanning heart ventricles and of 201 Tl in scintiscanning myocardial perfusion. The exercise ventricular function and perfusion scintigraphies are compared with the common exercise ECG examination, and their superior sensitivity and specificity emphasized. Considering the constraints of scintigraphic imaging, indications are outlined for patients including those with suspect serious ischemic heart disease in whom the exercise ECG test has been negative or inconclusive, patients with the so-called nondiagnostic ECG, patients with atypical symptoms, and healthy individuals for whom the exercise ECG test indicated with respect to their occupation has been positive. Both radionuclide imaging techniques are complementary and are shown to be valuable not only in improving the diagnosis of ischemic heart disease but also in identifying the high-risk patients in whom cardiac surgery is to be considered. (L.O.)

  18. The radionuclide migration model in river system

    International Nuclear Information System (INIS)

    Zhukova, O.M.; Shiryaeva, N.M.; Myshkina, M.K.; Shagalova, Eh.D.; Denisova, V.V.; Skurat, V.V.

    2001-01-01

    It was propose the model of radionuclide migration in river system based on principle of the compartmental model at hydraulically stationary and chemically equilibrium conditions of interaction of radionuclides in system water-dredge, water-sediments. Different conditions of radioactive contamination entry in river system were considered. The model was verified on the data of radiation monitoring of Iput' river

  19. Modeling Radionuclide Decay Chain Migration Using HYDROGEOCHEM

    Science.gov (United States)

    Lin, T. C.; Tsai, C. H.; Lai, K. H.; Chen, J. S.

    2014-12-01

    Nuclear technology has been employed for energy production for several decades. Although people receive many benefits from nuclear energy, there are inevitably environmental pollutions as well as human health threats posed by the radioactive materials releases from nuclear waste disposed in geological repositories or accidental releases of radionuclides from nuclear facilities. Theoretical studies have been undertaken to understand the transport of radionuclides in subsurface environments because that the radionuclide transport in groundwater is one of the main pathway in exposure scenarios for the intake of radionuclides. The radionuclide transport in groundwater can be predicted using analytical solution as well as numerical models. In this study, we simulate the transport of the radionuclide decay chain using HYDROGEOCHEM. The simulated results are verified against the analytical solution available in the literature. Excellent agreements between the numerical simulation and the analytical are observed for a wide spectrum of concentration. HYDROGECHEM is a useful tool assessing the ecological and environmental impact of the accidental radionuclide releases such as the Fukushima nuclear disaster where multiple radionuclides leaked through the reactor, subsequently contaminating the local groundwater and ocean seawater in the vicinity of the nuclear plant.

  20. Fire fighting in a radionuclide laboratory

    International Nuclear Information System (INIS)

    Wenzel, H.

    1991-01-01

    A fire-brigade was called to a laboratory which held a handling licence for the radionuclides C-14, T, P-32, Se-75, Mo-99, and S-35. The fire-brigade was unaware of a release of radionuclides. Therefore they used respiratory equipment, and all persons present were subsequently examined for contamination. (DG) [de

  1. Mechanisms of radionuclide transition in natural environment

    International Nuclear Information System (INIS)

    Pacyna, J.

    1974-01-01

    Mechanisms of radionuclide transition in various elements of the environment have been dealt with in an ecological aspect. The knowledge of the radionuclide propagation tracks will make possible to ascertain precisely causes and effects of the radiation and to reduce the contamination value. Particular attention has been paid to test methods. (author)

  2. Sensors and Automated Analyzers for Radionuclides

    International Nuclear Information System (INIS)

    Grate, Jay W.; Egorov, Oleg B.

    2003-01-01

    The production of nuclear weapons materials has generated large quantities of nuclear waste and significant environmental contamination. We have developed new, rapid, automated methods for determination of radionuclides using sequential injection methodologies to automate extraction chromatographic separations, with on-line flow-through scintillation counting for real time detection. This work has progressed in two main areas: radionuclide sensors for water monitoring and automated radiochemical analyzers for monitoring nuclear waste processing operations. Radionuclide sensors have been developed that collect and concentrate radionuclides in preconcentrating minicolumns with dual functionality: chemical selectivity for radionuclide capture and scintillation for signal output. These sensors can detect pertechnetate to below regulatory levels and have been engineered into a prototype for field testing. A fully automated process monitor has been developed for total technetium in nuclear waste streams. This instrument performs sample acidification, speciation adjustment, separation and detection in fifteen minutes or less

  3. Speciation of radionuclides in the environment

    International Nuclear Information System (INIS)

    Gunten, H.R. von; Benes, P.

    1994-02-01

    Methods for the determination of the speciation of radionuclides in aerosols, in aquatic solutions, in sediments, soils and rocks are reviewed. At present, most of the results about speciation are deduced from model calculations, model experiments, and separation of species (forms) of radionuclides, e.g., by sequential extraction procedures. Methods of direct determination of speciation of radionuclides (e.g. by laser induced spectroscopy) are in general not yet sensitive enough for a measurement of the very low concentrations of radionuclides in the environment. The methodological part of this paper is followed by a review of the very abundant literature about speciation of important radionuclides in the environment, i.e. in the atmosphere, hydrosphere and lithosphere. The review does not include the biosphere. Literature up to spring 1993 is included (with a few more recent additions). (author)

  4. Radionuclide transport in a single fissure

    International Nuclear Information System (INIS)

    Eriksen, T.E.

    1983-01-01

    Radionuclide migration have been studied in natural fissures orieted parallel to the axis of granite drill cores. A short pulse of the radionuclides solution was injected at one end of the fissure and the temporal change in radionuclide concentration of the eluate measured. After several hundred fissure volumes water had been pumped through the fissure following the radionuclide pulse the activity distribution on the fissure surfaces was measured. From the retardation of 152 Eu, 235 Np and 237 Pu it is concluded that these radionuclides are transported in the oxidation states Eu(III), Pu(IV) and Np(V). The distribution coefficients K sub (d) calculated from flow and activity distribution data on the basis of geometric surface area/volume ratios are of the same order as published K sub (d) values obtained from batch equilibrium experiments. (Author)

  5. Radionuclides in the environment: Risks and opportunities

    International Nuclear Information System (INIS)

    Elzerman, A.W.

    1993-01-01

    Environmental chemistry plays a critical role in the open-quotes nuclear ageclose quotes. It makes a vital contribution to understanding of the sources, fate and effects of radionuclides in the environment, both man-made and natural. Risk assessment of radionuclides in the environment relies heavily on the tools of environmental chemistry. On the other hand, radionuclides provide unique opportunities to exploit in environmental chemistry investigations due to their well-defined sources, traceability in environmental processes, analytical sensitivities, and open-quotes built-inclose quotes radioactive decay open-quotes clocksclose quotes. In some cases naturally present radionuclides are utilized, while in others tracers are deliberately added or have already been added by the nuclear fuel cycle or nuclear testing. Several examples in each of these categories are discussed to spotlight the current status of environmental chemistry and radionuclides in the environment as an example application

  6. Mobility and Bioavailability of Radionuclides in Soils

    International Nuclear Information System (INIS)

    Iurian, A.; Olufemi Phaneuf, M.; Mabit, L.

    2016-01-01

    It is crucial to understand the behavior of radionuclides in the environment, their potential mobility and bioavailability related to long-term persistence, radiological hazards, and impact on human health. Such key information is used to develop strategies that support policy decisions. The environmental behavior of radionuclides depends on ecosystem characteristics. A given soil’s capacity to immobilize radionuclides has been proved to be the main factor responsible for their resulting activity concentrations in plants. The mobility and bioavailability of radionuclides in soils is complex, depending on clay-sized soil fraction, clay mineralogy, organic matter, cation exchange capacity, pH and quantities of competing cations. Moreover, plant species have different behaviors regarding radionuclide absorption depending on soil and plan characteristics

  7. An intercomparison on radionuclides in environmental samples, Baltic-Danish co-operation project on radiation protection 2001-2003

    International Nuclear Information System (INIS)

    Nielsen, S.P.

    2004-07-01

    Sixteen laboratories participated in an intercomparison exercise carried out in 2003 on laboratory analyses of radionuclides in environmental samples. The sample types included seawater, lake water, soil, dry milk and seaweed and the exercise involved the radionuclides 137 Cs, 90 Sr, 60 Co, 239,240 Pu, 241 Am, 226 Ra, 2 40 K. The evaluation of analytical performance was based on comparison with median values, a 10% target standard deviation and statistical tests at the 99% level. For 137Cs the results from 10 out of 16 laboratories passed the evaluation tests. For 90 Sr the results from 5 out of 12 laboratories passed the evaluation tests. For 60 Co, 239,240 Pu and 241 Am two laboratories submitted results and both passed the tests. For the natural radionuclides 226 Ra, 232 Th and 40 K, only a few laboratories did not pass the tests. For all radionuclides combined, the results from 6 out of 16 laboratories passed the evaluation tests. The results indicate that for several of the laboratories there is room to improve the analytical quality on radionuclides in environmental samples to match an uncertainty corresponding to a relative standard deviation of 10%. (au)

  8. Intercomparison of radionuclide measurements in marine sediment sample IAEA-135

    International Nuclear Information System (INIS)

    Ballestra, S.; Gastaud, J.; Lopez, J.J.; Parsi, P.; Vas, D.

    1993-08-01

    The results of an intercomparison exercise on a marine sediment from Irish Sea, IAEA-135, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 151 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, for 40 K, 60 Co, 134 Cs, 137 Cs, 154 Eu, 155 Eu, 226 Ra, 228 Ra, 232 Th, 238 Pu, 239+240 Pu (Reference date: 1 January 1992). Information values for 57 Co, 90 Sr, 106 Ru, 125 Sb, 210 Pb, 210 Po, 228 Th, 230 Th, 234 U, 235 U, 238 U and 241 Am are also reported. All values are expressed in Bq kg -1 dry weight. (author)

  9. Intercomparison of radionuclide measurements in marine sediment sample IAEA-135

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Gastaud, J; Lopez, J J; Parsi, P; Vas, D

    1993-08-01

    The results of an intercomparison exercise on a marine sediment from Irish Sea, IAEA-135, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 151 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, for {sup 40}K, {sup 60}Co, {sup 134}Cs, {sup 137}Cs, {sup 154}Eu, {sup 155}Eu, {sup 226}Ra, {sup 228}Ra, {sup 232}Th,{sup 238}Pu, {sup 239+240}Pu (Reference date: 1 January 1992). Information values for {sup 57}Co, {sup 90}Sr, {sup 106}Ru, {sup 125}Sb, {sup 210}Pb, {sup 210}Po, {sup 228}Th, {sup 230}Th, {sup 234}U, {sup 235}U, {sup 238}U and {sup 241}Am are also reported. All values are expressed in Bq kg{sup -1} dry weight. (author)

  10. Intercomparison of radionuclide measurements in marine sediment sample IAEA-368

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Lopez, J J; Gastaud, J; Parsi, P; Vas, D; Noshkin, V

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-368, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 89 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for {sup 60}Co, {sup 155}Eu, {sup 210}7Pb, {sup 226}Ra, {sup 238}U, {sup 238}Pu and{sup 239+240}Pu (Reference date: 1 January 1990). Information values for {sup 40}K, {sup 90}Sr, {sup 137}Cs, {sup 228}Th, {sup 230}Th, {sup 232}Th, {sup 234}U, {sup 235}U and {sup 241}Am are also reported. (author)

  11. Intercalibration of selected anthropogenic radionuclides for the GEOTRACES Program

    DEFF Research Database (Denmark)

    Kenna, Timothy C.; Masqué, Pere; Mas, Jose Luis

    2012-01-01

    As part of the GEOTRACES Program, six laboratories participated in an intercalibration exercise on several anthropogenic radionuclides of interest. The effort was successful for 239,240Pu activity, 240Pu/239Pu isotope ratio, and 137Cs activity measured in filtered seawater samples from the Bermuda...... Atlantic Time Series station (BATS) and a site on the continental slope of the Northeastern U.S. A limited number of analyses were reported for 237Np, 241Am, 90Sr, and 238Pu in filtered seawater. Intercalibration of any of the isotopes of interest in filtered particulate matter was unsuccessful due...... to insufficient size of the samples distributed. Methods used were based on traditional radio-counting techniques and inductively coupled plasma mass spectrometry (ICP-MS). Although the majority of analyses were performed on samples ≥ 60 L, one lab demonstrated the ability to analyze several of the anthropogenic...

  12. Intercomparison of radionuclide measurements on marine sediment sample IAEA-300

    International Nuclear Information System (INIS)

    Ballestra, S.; Gastaud, J.; Lopez, J.J.; Parsi, P.; Vas, D.

    1994-09-01

    The results of an intercomparison exercise on a sediment from Baltic Sea, IAEA-300, designed for the determination of artificial and natural radionuclides' levels, are reported. The data from 159 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, 40 K, 60 Co, 125 Sb, 134 Cs, 137 Cs, 155 Eu, 210 Pb, 210 Po, 228 Ra, 234 U, 238 U, 239+240 Pu and 241 Am. Information values for 54 Mn, 90 Sr, 226 Ra, 228 Th, 230 Th, 232 Th, 235 U and 238 Pu are also reported. All values are given on the reference date of 1 January 1993 and expressed in Bq kg -1 dry weight. (author)

  13. Intercomparison of radionuclide measurements on marine sediment sample IAEA-300

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Gastaud, J; Lopez, J J; Parsi, P; Vas, D

    1994-09-01

    The results of an intercomparison exercise on a sediment from Baltic Sea, IAEA-300, designed for the determination of artificial and natural radionuclides' levels, are reported. The data from 159 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, {sup 40}K, {sup 60}Co, {sup 125}Sb, {sup 134}Cs, {sup 137}Cs, {sup 155}Eu, {sup 210}Pb, {sup 210}Po, {sup 228}Ra, {sup 234}U, {sup 238}U, {sup 239+240}Pu and {sup 241}Am. Information values for {sup 54}Mn, {sup 90}Sr, {sup 226}Ra, {sup 228}Th, {sup 230}Th, {sup 232}Th, {sup 235}U and {sup 238}Pu are also reported. All values are given on the reference date of 1 January 1993 and expressed in Bq kg{sup -1} dry weight. (author)

  14. Radionuclide imaging of spinal infections

    International Nuclear Information System (INIS)

    Gemmel, Filip; Dumarey, Nicolas; Palestro, Christopher J.

    2006-01-01

    The diagnosis of spinal infection, with or without implants, has been a challenge for physicians for many years. Spinal infections are now being recognised more frequently, owing to aging of the population and the increasing use of spinal-fusion surgery. The diagnosis in many cases is delayed, and this may result in permanent neurological damage or even death. Laboratory evidence of infection is variable. Conventional radiography and radionuclide bone imaging lack both sensitivity and specificity. Neither in vitro labelled leucocyte scintigraphy nor 99m Tc-anti-granulocyte antibody scintigraphy is especially useful, because of the frequency with which spinal infection presents as a non-specific photopenic area on these tests. Sequential bone/gallium imaging and 67 Ga-SPECT are currently the radionuclide procedures of choice for spinal osteomyelitis, but these tests lack specificity, suffer from poor spatial resolution and require several days to complete. [ 18 F]Fluoro-2-deoxy-D-glucose (FDG) PET is a promising technique for diagnosing spinal infection, and has several potential advantages over conventional radionuclide tests. The study is sensitive and is completed in a single session, and image quality is superior to that obtained with single-photon emitting tracers. The specificity of FDG-PET may also be superior to that of conventional tracers because degenerative bone disease and fractures usually do not produce intense FDG uptake; moreover, spinal implants do not affect FDG imaging. However, FDG-PET images have to be read with caution in patients with instrumented spinal-fusion surgery since non-specific accumulation of FDG around the fusion material is not uncommon. In the future, PET-CT will likely provide more precise localisation of abnormalities. FDG-PET may prove to be useful for monitoring response to treatment in patients with spinal osteomyelitis. Other tracers for diagnosing spinal osteomyelitis are also under investigation, including radiolabelled

  15. Radionuclide imaging of spinal infections

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [Ghent Maria-Middelares, General Hospital, Division of Nuclear Medicine, Ghent (Belgium); Medical Center Leeuwarden (MCL), Division of Nuclear Medicine, Henri Dunantweg 2, Postbus 888, Leeuwarden (Netherlands); Dumarey, Nicolas [Universite Libre de Bruxelles, Hopital Erasme, Division of Nuclear Medicine, Brussels (Belgium); Palestro, Christopher J. [Long Island Jewish Medical Center, Division of Nuclear Medicine, Long Island, NY (United States)

    2006-10-15

    The diagnosis of spinal infection, with or without implants, has been a challenge for physicians for many years. Spinal infections are now being recognised more frequently, owing to aging of the population and the increasing use of spinal-fusion surgery. The diagnosis in many cases is delayed, and this may result in permanent neurological damage or even death. Laboratory evidence of infection is variable. Conventional radiography and radionuclide bone imaging lack both sensitivity and specificity. Neither in vitro labelled leucocyte scintigraphy nor {sup 99m}Tc-anti-granulocyte antibody scintigraphy is especially useful, because of the frequency with which spinal infection presents as a non-specific photopenic area on these tests. Sequential bone/gallium imaging and {sup 67}Ga-SPECT are currently the radionuclide procedures of choice for spinal osteomyelitis, but these tests lack specificity, suffer from poor spatial resolution and require several days to complete. [{sup 18}F]Fluoro-2-deoxy-D-glucose (FDG) PET is a promising technique for diagnosing spinal infection, and has several potential advantages over conventional radionuclide tests. The study is sensitive and is completed in a single session, and image quality is superior to that obtained with single-photon emitting tracers. The specificity of FDG-PET may also be superior to that of conventional tracers because degenerative bone disease and fractures usually do not produce intense FDG uptake; moreover, spinal implants do not affect FDG imaging. However, FDG-PET images have to be read with caution in patients with instrumented spinal-fusion surgery since non-specific accumulation of FDG around the fusion material is not uncommon. In the future, PET-CT will likely provide more precise localisation of abnormalities. FDG-PET may prove to be useful for monitoring response to treatment in patients with spinal osteomyelitis. Other tracers for diagnosing spinal osteomyelitis are also under investigation, including

  16. Effect of chronic L-thyroxine-suppressive therapy on cardiac function in patients with differentiated thyroid carcinoma: Radionuclide techniques

    International Nuclear Information System (INIS)

    Ziada, G.; Farouk, S.; Zidan, A.; Mustafa, S.; El-Reffaie, S.

    2005-01-01

    Differentiated thyroid carcinoma (DTC) is usually treated by a combination of surgery, radioiodine (I-131) and suppressive doses of thyroid hormones [L-thyroxine (Eltroxine)]. It is well-known that thyroid hormone affects the function of cardiovascular system. However there is no study to objectively substantiate this phenomenon. The objective of this study was to assess the left ventricular function with the help of radionuclide ventriculography in patients of DTC. Various parameters of systolic function [ejection fraction (EF), peak ejection rate (PER) and time to peak ejection rate (TPER)], diastolic function [peak filling rate (PFR) and time to peak filling rate (TPFR)] and heart rate were determined. Ten healthy control subjects and 50 patients of DTC on suppressive doses of eltroxine following surgery and radio-iodine (I-131) therapy were evaluated. The patients were divided into 5 groups according to their clinical status and thyroid hormone profile. These groups were: euthyroid, sub-clinical hypothyroid, hypothyroid, sub-clinical hyperthyroid and hyperthyroid groups. The results of the study revealed that Eltroxine significantly affected left ventricular function. Although it did not affect the systolic function, the diastolic function was significantly impaired. Prolongation of TPER was noted in hypothyroid patients, while the same was significantly decreased in hyper- and sub-clinical hyper-thyroids patients. Such abnormalities in cardiac function would be responsible for serious morbidity and could affect the lives of patients' in several ways. Hence, early effective treatment of thyroid function is important in patients of DTC, which would improve their quality of life and avoid long-term serious or irreversible cardiovascular disorder. (author)

  17. Radionuclide interactions with marine sediments

    International Nuclear Information System (INIS)

    Higgo, J.J.W.

    1987-09-01

    A critical review of the literature on the subject of the interactions of radionuclides with marine sediments has been carried out. On the basis of the information available, an attempt has been made to give ranges and 'best estimates' for the distribution ratios between seawater and sediments. These estimates have been based on an understanding of the sediment seawater system and the porewater chemistry and mineralogy. Field measurements, laboratory measurements and estimates based on stable-element geochemical data are all taken into account. Laboratory measurements include distribution-ratio and diffusion-coefficient determinations. The elements reviewed are carbon, chlorine, calcium, nickel, selenium, strontium, zirconium, niobium, technetium, tin, iodine, caesium, lead, radium, actinium, thorium, protactinium, uranium, neptunium, plutonium, americium and curium. (author)

  18. Expert system based radionuclide identification

    International Nuclear Information System (INIS)

    Aarnio, P.A.; Ala-Heikkil, J.J.; Hakulinen, T.T.; Nikkinen, M.T.

    1998-01-01

    An expert system coupled with the gamma spectrum analysis system SAMPO has been developed for automating the qualitative identification of radionuclides as well as for determining the quantitative parameters of the spectrum components. The program is written in C-language and runs in various environments ranging from PCs to UNIX workstations. The expert system utilizes a complete gamma library with over 2600 nuclides and 80,000 lines, and a rule base of about fifty criteria including energies, relative peak intensities, genesis modes, half lives, parent-daughter relationships, etc. The rule base is furthermore extensible by the user. This is not an original contribution but a somewhat updated version of papers and reports previously published elsewhere. (author)

  19. Radionuclide diagnosis of allograft rejection

    International Nuclear Information System (INIS)

    George, E.A.

    1982-01-01

    Interaction with one or more anatomical and physiopathological characteristics of the rejecting renal allograft is suggested by those radioagents utilized specifically for the diagnosis of allograft rejection. Rejection, the most common cause of declining allograft function, is frequently mimicked clinically or masked by other immediate or long term post transplant complications. Understanding of the anatomical pathological features and kinetics of rejection and their modification by immunosuppressive maintenance and therapy are important for the proper clinical utilization of these radioagents. Furthermore, in selecting these radionuclides, one has to consider the comparative availability, preparatory and procedural simplicity, acquisition and display techniques and the possibility of timely report. The clinical utilities of radiofibrinogen, /sup 99m/Tc sulfur colloid and 67 Ga in the diagnosis of allograft rejection have been evaluated to a variable extent in the past. The potential usefulness of the recently developed preparations of 111 In labeled autologous leukocytes and platelets are presently under investigation

  20. Quality assurance in radionuclide laboratories

    International Nuclear Information System (INIS)

    Otto, R.; Voelkle, H.; Wershofen, H.; Wilhelm, C.

    2003-01-01

    The authors are members of an ad-hoc working group preparing a contribution to the procedures manual (''Loseblattsammlung'') dealing with quality assurance and quality control in radionuclide laboratories. The Loseblattsammlung is edited by the working group ''Environmental Monitoring'' of the German-Swiss Radiological Protection Association. The intention of the manual under preparation is not to give a procedure on how to establish a quality management system allowing for an accreditation in accordance with the international standard DIN EN ISO/IEC 17025:2000 04 (''ISO 17025'') [1] but to compile routine quality control procedures necessary for reliable measurements and to give tips to the practitioner on how to keep both the extent and the frequency of procedures on a reasonable level. A short version of the Loseblatt is presented here. (orig.)

  1. Placental transfer of other radionuclides

    International Nuclear Information System (INIS)

    Stieve, F.-E.

    1987-01-01

    This paper comments upon some basic principles of the transfer of radioactive substances in human beings to the embryo and fetus and their age-dependence. These principles may apply to the main effects currently known from the uptake, accumulation, retention and excretion of those radioactive substances, which may be of special interest in assessing the dose and therefore the risk of exposure in nuclear medicine, in connection with environmental problems of nuclear power production as well as nuclear explosions. As an example the age-dependence of several typical radionuclides and their age-dependence during the development of the human embryo and fetus and its correlation to observations on several animal species are presented. 30 refs.; 5 figs

  2. Transverse section radionuclide scanning system

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Edwards, R.Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program. 5 claims, 11 figures

  3. Radionuclide evaluation of brain death

    International Nuclear Information System (INIS)

    Pjura, G.A.; Kim, E.E.

    1987-01-01

    The criteria employed for clinical determination of death have evolved in response to advances in life support and other medical technology. The technical feasibility of organ transplantation has amplified the need for a definition of brain death that can be applied in the shortest possible time in the presence of artificial maintenance of vegetative functions, including circulation. Radionuclide cerebral angiography is one of a group of diagnostic procedures that can be employed to confirm the clinical diagnosis of brain death through demonstration of absence of cerebral blood flow. The focus of this work is to assess its use as a confirmatory test for determination of brain death in the context of currently available alternative technologies

  4. Radionuclide diagnosis of vasculogenic impotence

    International Nuclear Information System (INIS)

    Sorokin, A.I.; Gerasimov, V.G.; Lenskaya, O.P.; Narkevich, B.Ya.; Bogdasarov, Yu.B.; Krotovskij, G.S.

    1988-01-01

    Pathogenesis of vasculogenic impotence is most adequately revealed by modern methods of the investigation of the hemodynamic mechanisms of erection with the enhancement of arterial perfusion of corpora cavernosa by artificial sexual stimulation. Radionuclide diagnostic methods effectively differ from the methods of radiocontrast phalloangiography by the simplicity of investigation and the absence of traumatism for a patient. The authors have proposed a mathematical model of a process of filling in the functioning volume of the penile vascular bed with a radiopharmaceutical prepation against the background of erection induced by intracavernous administration of papaverine hydrochloride solution. Parameters of the model determine the ratio of blood flow volumetric rates in the penis at rest and when erect

  5. Decontamination of radionuclides in food

    Energy Technology Data Exchange (ETDEWEB)

    Ohmomo, Yoichiro [Institute for Environmental Sciences, Aomori (Japan)

    1994-03-01

    The release of radionuclides arising from the Chernobyle accident led to widespread contamination of the northern hemisphere through fallout. This accident provided again an opportunity to investigate how and to what extent the radionuclides contamination in crops and animal derived foods could be reduced. The following topics are included in this paper. (1) How to reduce the transfer of radiostrontium and/or cesium from soil to crops: A pH increase of soil is effective for reducing their plant uptake. (2) How to reduce the transfer of radiocesium to animal derived foods: Ammonium-ferric-cyanoferrate (AFCF) should be the most effective compound for radiocesium excretion in the feces. Experiments with lactating cows and/or poultry gave extremely good results with respect to low radiocesium concentrations in milk, meat and eggs. (3) Removal coefficients of radiostrontium, cesium and iodine from contaminated leaf vegetables and cereals during food processing and culinary preparation: Though different by species, more than 80% of cesium and about 50% of strontium and iodine can be removed during culinary preparation of washing and boiling. (4) Simultaneous decontamination of radiocesium and iodine from drinking water and liquid milk: Metal ferrocyanide-anion exchange resin, specifically Fe ferrocyanide one, was successfully used for a rapid and simple decontamination of radiocesium and iodine in the liquid samples arising from the Chernobyle accident. (5) Removal of radiocesium from meat: The meat structurally contaminated with radiocesium is easily and very successfully decontaminated by pickling in NaCl solution and the decontamination is much speeded up by freezing meat before pickling. (author).

  6. Illicit Trafficking of Natural Radionuclides

    International Nuclear Information System (INIS)

    Friedrich, Steinhaeusler; Lyudmila, Zaitseva

    2008-01-01

    Natural radionuclides have been subject to trafficking worldwide, involving natural uranium ore (U 238), processed uranium (yellow cake), low enriched uranium ( 20% U 235), radium (Ra 226), polonium (Po 210), and natural thorium ore (Th 232). An important prerequisite to successful illicit trafficking activities is access to a suitable logistical infrastructure enabling an undercover shipment of radioactive materials and, in case of trafficking natural uranium or thorium ore, capable of transporting large volumes of material. Covert en route diversion of an authorised uranium transport, together with covert diversion of uranium concentrate from an operating or closed uranium mines or mills, are subject of case studies. Such cases, involving Israel, Iran, Pakistan and Libya, have been analyzed in terms of international actors involved and methods deployed. Using international incident data contained in the Database on Nuclear Smuggling, Theft and Orphan Radiation Sources (DSTO) and international experience gained from the fight against drug trafficking, a generic Trafficking Pathway Model (TPM) is developed for trafficking of natural radionuclides. The TPM covers the complete trafficking cycle, ranging from material diversion, covert material transport, material concealment, and all associated operational procedures. The model subdivides the trafficking cycle into five phases: (1) Material diversion by insider(s) or initiation by outsider(s); (2) Covert transport; (3) Material brokerage; (4) Material sale; (5) Material delivery. An Action Plan is recommended, addressing the strengthening of the national infrastructure for material protection and accounting, development of higher standards of good governance, and needs for improving the control system deployed by customs, border guards and security forces

  7. Illicit Trafficking of Natural Radionuclides

    Science.gov (United States)

    Friedrich, Steinhäusler; Lyudmila, Zaitseva

    2008-08-01

    Natural radionuclides have been subject to trafficking worldwide, involving natural uranium ore (U 238), processed uranium (yellow cake), low enriched uranium (20% U 235), radium (Ra 226), polonium (Po 210), and natural thorium ore (Th 232). An important prerequisite to successful illicit trafficking activities is access to a suitable logistical infrastructure enabling an undercover shipment of radioactive materials and, in case of trafficking natural uranium or thorium ore, capable of transporting large volumes of material. Covert en route diversion of an authorised uranium transport, together with covert diversion of uranium concentrate from an operating or closed uranium mines or mills, are subject of case studies. Such cases, involving Israel, Iran, Pakistan and Libya, have been analyzed in terms of international actors involved and methods deployed. Using international incident data contained in the Database on Nuclear Smuggling, Theft and Orphan Radiation Sources (DSTO) and international experience gained from the fight against drug trafficking, a generic Trafficking Pathway Model (TPM) is developed for trafficking of natural radionuclides. The TPM covers the complete trafficking cycle, ranging from material diversion, covert material transport, material concealment, and all associated operational procedures. The model subdivides the trafficking cycle into five phases: (1) Material diversion by insider(s) or initiation by outsider(s); (2) Covert transport; (3) Material brokerage; (4) Material sale; (5) Material delivery. An Action Plan is recommended, addressing the strengthening of the national infrastructure for material protection and accounting, development of higher standards of good governance, and needs for improving the control system deployed by customs, border guards and security forces.

  8. Decontamination of radionuclides in food

    International Nuclear Information System (INIS)

    Ohmomo, Yoichiro

    1994-01-01

    The release of radionuclides arising from the Chernobyle accident led to widespread contamination of the northern hemisphere through fallout. This accident provided again an opportunity to investigate how and to what extent the radionuclides contamination in crops and animal derived foods could be reduced. The following topics are included in this paper. (1) How to reduce the transfer of radiostrontium and/or cesium from soil to crops: A pH increase of soil is effective for reducing their plant uptake. (2) How to reduce the transfer of radiocesium to animal derived foods: Ammonium-ferric-cyanoferrate (AFCF) should be the most effective compound for radiocesium excretion in the feces. Experiments with lactating cows and/or poultry gave extremely good results with respect to low radiocesium concentrations in milk, meat and eggs. (3) Removal coefficients of radiostrontium, cesium and iodine from contaminated leaf vegetables and cereals during food processing and culinary preparation: Though different by species, more than 80% of cesium and about 50% of strontium and iodine can be removed during culinary preparation of washing and boiling. (4) Simultaneous decontamination of radiocesium and iodine from drinking water and liquid milk: Metal ferrocyanide-anion exchange resin, specifically Fe ferrocyanide one, was successfully used for a rapid and simple decontamination of radiocesium and iodine in the liquid samples arising from the Chernobyle accident. (5) Removal of radiocesium from meat: The meat structurally contaminated with radiocesium is easily and very successfully decontaminated by pickling in NaCl solution and the decontamination is much speeded up by freezing meat before pickling. (author)

  9. Serial assessment of left ventricular function following coronary bypass surgery by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Kawasuji, Michio; Sawa, Shigeharu; Sakakibara, Naoki; Iwa, Takashi; Taki, Junichi; Bunko, Hisashi

    1988-01-01

    The serial change in left ventricular function was investigated by radionuclide angiocardiography in 25 patients undergoing coronary artery bypass grafting (CABG). Multiple gated equilibrium blood pool imaging was performed at rest before, and at 1, 2 and 4 weeks after the operation and also during exercise on a supine bicycle ergometer before and 4 weeks after surgery. Global ejection fraction at rest was unchanged after CABG while peak ejection rate increased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05 respectively) after the operation. Peak filling rate at rest was generally unchanged after surgery but peak filling rate during the first third of diastole at rest decreased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05). After CABG, the increases in ejection fraction and peak ejection rate with exercise were significantly greater than those values measured before surgery. The increases, due to exercise, in peak filling rate and peak filling rate during the first third of diastole were unchanged after the operation. Radionuclide angiocardiography affords a safe, noninvasive, and highly reproducible procedure for serially assessing ventricular function in patients undergoing CABG. Our study revealed early diastolic dysfunction within 2 weeks of surgery and that CABG abolished abnormalities in left ventricular function induced by exercise. (author)

  10. Submaximal exercise thallium-201 SPECT for assessment of interventional therapy in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Stewart, R.E.; Kander, N.; Juni, J.E.; Ellis, S.G.; O'Neill, W.W.; Schork, M.A.; Topol, E.J.; Schwaiger, M.

    1991-01-01

    Submaximal thallium-201 stress testing has been shown to provide important diagnostic and prognostic information in patients with acute myocardial infarction. The purpose of this investigation was to evaluate the diagnostic value of early submaximal stress testing and thallium-201 single photon emission computed tomography (SPECT) after interventional therapy. Scintigraphic results from 56 patients with infarctions, who underwent acute thrombolytic therapy, angioplasty, or both, were compared with late (6 weeks) functional outcome as assessed by radionuclide ventriculography and with results of discharge coronary angiography. A linear correlation was found between the extent of thallium-201 SPECT perfusion defect and late ventricular function (r = 0.74, p less than 0.01). Forty-two percent of patients with large SPECT perfusion defects had normal left ventricular ejection fractions, suggesting an overestimation of infarct size by early imaging. Sensitivity and specificity of thallium-201 SPECT for detection of coronary artery stenosis in noninfarct territories was 57% and 46%, respectively, indicating limited diagnostic definition of extent of underlying coronary artery disease. Results of follow-up coronary angiography showed a significant relationship between the size of the initial perfusion defect and early restenosis or reocclusion of the infarct artery. Thus the extent of early thallium-201 perfusion defects correlates with late functional outcome but appears to overestimate the degree of injury. Submaximal thallium-201 stress testing allows only limited characterization of underlying coronary artery disease. Early assessment of infarct size may identify a patient population at high risk for reocclusion of the infarct artery

  11. Myocardial involvement in diabetic patients evaluated by exercise thallium-201 scintigraphy and cardiac catheterization

    International Nuclear Information System (INIS)

    Mizuno, Sumio; Genda, Akira; Nakayama, Akira; Igarashi, Yutaka; Takeda, Ryoyu

    1985-01-01

    To evaluate myocardial involvement in diabetes mellitus, we studied 39 patients with negative double-Master's test and without hypertension by exercise thallium-201 (Tl-201) myocardial scintigraphy using a bicycle ergometer. Among the 39 patients, 12 (30.8 %) showed filling defects in the scintigrams (positive cases), including eight with stress-induced defects and four with fixed defects. The positive cases had higher scores of diabetic complications (3.6 +- 2.4 vs 2.1 +- 1.8; p < 0.05) and longer durations of diabetes as compared with those of the negative cases. The frequency of insulin therapy was also greater in the positive cases. Eleven patients (5 positive and 6 negative cases) who underwent cardiac catheterization had no significant stenotic lesions of their coronary arteries. However, all of the positive cases showed abnormal wall motion, mainly hypokinesis, by left ventriculography (LVG). The abnormalities of the LVG corresponded to the findings of the scintigrams (i.e. filling defects and decrease in washout ratios by circumferential profile analysis). These results suggest that in some diabetics myocardial involvement exists in the early stage without overt cardiac disease and exercise Tl-201 scintigraphy is useful in detecting pre-clinical cardiomyopathy. Cardiomyopathy in diabetics seems to be due to disturbances of the myocardial microcirculation. (author)

  12. Human dose pathways of radionuclides in forests

    International Nuclear Information System (INIS)

    Rantavaara, A.

    2009-01-01

    Forest soil, understorey vegetation and trees are all sources of radionuclides and human radiation doses after contaminating atmospheric deposition. People are exposed to radiation externally from sources outside the body and internally via ingestion and inhalation of radionuclides. Understorey vegetation contributes to ingestion doses through berries, herbs, wild honey, mushrooms and game meat; also trees provide feed to terrestrial birds and big game. During stay in forests people are subject to external radiation from forest floor and overstorey, and they may inhale airborne radioactive aerosol or gaseous radionuclides in ground level air. In the early phase of contamination also resuspended radionuclides may add to the internal dose of people via inhalation. People in Nordic countries are most exposed to radiation via ingestion of radionuclides in wild foods. The distribution of radionuclides in forests is changed by environmental processes, and thereby also the significance of various dose pathways to humans will change with time. External exposure is received in living environment from contaminated stemwood used as building timber and for manufacturing of furniture and other wood products. The aim of this paper is to outline the significance of various human dose pathways of radionuclides in forests considering the public and workers in forestry and production of bioenergy. Examples on effective doses are given based on two historical events, atmospheric nuclear weapon tests (mostly in 1950's and in 1960's) and the Chernobyl nuclear power plant accident in 1986. (au)

  13. Radionuclides: Accumulation and Transport in Plants.

    Science.gov (United States)

    Gupta, D K; Chatterjee, S; Datta, S; Voronina, A V; Walther, C

    Application of radioactive elements or radionuclides for anthropogenic use is a widespread phenomenon nowadays. Radionuclides undergo radioactive decays releasing ionizing radiation like gamma ray(s) and/or alpha or beta particles that can displace electrons in the living matter (like in DNA) and disturb its function. Radionuclides are highly hazardous pollutants of considerable impact on the environment, food chain and human health. Cleaning up of the contaminated environment through plants is a promising technology where the rhizosphere may play an important role. Plants belonging to the families of Brassicaceae, Papilionaceae, Caryophyllaceae, Poaceae, and Asteraceae are most important in this respect and offer the largest potential for heavy metal phytoremediation. Plants like Lactuca sativa L., Silybum marianum Gaertn., Centaurea cyanus L., Carthamus tinctorius L., Helianthus annuus and H. tuberosus are also important plants for heavy metal phytoremediation. However, transfer factors (TF) of radionuclide from soil/water to plant ([Radionuclide]plant/[Radionuclide]soil) vary widely in different plants. Rhizosphere, rhizobacteria and varied metal transporters like NRAMP, ZIP families CDF, ATPases (HMAs) family like P1B-ATPases, are involved in the radio-phytoremediation processes. This review will discuss recent advancements and potential application of plants for radionuclide removal from the environment.

  14. Radionuclides in air, water, and biota

    International Nuclear Information System (INIS)

    Seymour, A.H.; Nelson, V.A.

    1977-01-01

    Air, water, and biological samples collected before and after the 1965, 1969, and 1971 underground nuclear detonations at Amchitka Island were analyzed for natural and fallout radionuclides by gamma spectrometry. Selected samples were also analyzed for tritium, 55 Fe, and 90 Sr. The objectives were to search for and identify radionuclides of Amchitka origin in the samples and to contribute to the general knowledge of the distribution of radionuclides in the environment. The studies showed that there has been no escape of radionuclides from the underground sites of the three nuclear detonations at Amchitka Island except for trace quantities of radionuclides, principally tritium, in water and soil gas samples from the immediate vicinity of the surface ground zero for the 1965 event. Two naturally occurring radionuclides, 40 K and 7 Be, were the most abundant radionuclides in the samples, usually by a factor of 10 or more, except for 137 Cs in lichen samples. All levels were well below applicable Radiation Protction Guides, often being near the statistical limit of detection

  15. Gastroesophageal reflux in children: radionuclide gastroesophagography

    International Nuclear Information System (INIS)

    Blumhagen, J.D.; Rudd, T.G.; Christie, D.L.

    1980-01-01

    Sixty-five symptomatic infants and children underwent radionuclide gastroesophagography, acid reflux testing, and barium esophagography with water-siphon testing to evaluate the clinical efficacy of the scintigraphic technique in detecting gastroesophageal reflux. After ingesting /sup 99m/Tc sulfur colloid in fruit juice, patients rested beneath the gamma camera for 30 to 60 min while esophageal activity was monitored continuously. By using the acid reflux test as a standard of comparison, the senstivity of radionuclide gastroesophagography was 75%. Because of its physiologic nature, low radiation exposure, and convenience, radionuclide gastroesophagography warrants further evaluation as a screening test for gastroesophageal reflux

  16. Determination of natural occurring radionuclides concentrations

    International Nuclear Information System (INIS)

    Stajic, J.; Markovic, V.; Krstic, D.; Nikezic, D.

    2011-01-01

    Tobacco smoke contains certain concentrations of naturally occurring radionuclides from radioactive chains of uranium and thorium - 214 Pb, 214 Bi, 228 Ac, 208 Tl, 226 Ra, 232 Th and 40 K. Inhaling of tobacco smoke leads to internal exposure of man. In order to estimate absorbed dose of irradiation it is necessary to determine concentrations of radionuclides present in the tobacco leaves. In this paper specific activities of naturally occurring radionuclides were measured in tobacco samples from cigarettes which are used in Serbia. [sr

  17. 2008 LANL radionuclide air emissions report

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David P.

    2009-06-01

    The emissions of radionuclides from Department of Energy Facilities such as Los Alamos National Laboratory (LANL) are regulated by the Amendments to the Clean Air Act of 1990, National Emissions Standards for Hazardous Air Pollutants (40 CFR 61 Subpart H). These regulations established an annual dose limit of 10 mrem to the maximally exposed member of the public attributable to emissions of radionuclides. This document describes the emissions of radionuclides from LANL and the dose calculations resulting from these emissions for calendar year 2008. This report meets the reporting requirements established in the regulations.

  18. 2010 LANL radionuclide air emissions report /

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David P.

    2011-06-01

    The emissions of radionuclides from Department of Energy Facilities such as Los Alamos National Laboratory (LANL) are regulated by the Amendments to the Clean Air Act of 1990, National Emissions Standards for Hazardous Air Pollutants (40 CFR 61 Subpart H). These regulations established an annual dose limit of 10 mrem to the maximally exposed member of the public attributable to emissions of radionuclides. This document describes the emissions of radionuclides from LANL and the dose calculations resulting from these emissions for calendar year 2010. This report meets the reporting requirements established in the regulations.

  19. Manual of bioassay procedures for radionuclides

    International Nuclear Information System (INIS)

    Pleskach, S.; Petkau, A.

    1986-06-01

    A monitoring program is described by which atomic radiation workers ar monitored for internal contamination with radionuclides in the workplace. The program involves analytical procedures for measuring alpha, beta and gamma activity in biological specimens, usually urine. Radionuclides are identified by their characteristic radiation using liquid scintillation counting, and alpha, beta and gamma spectrometry. Examples of calculating the minimum detectable activity for specific radionuclides are given and used to derive call-in-criteria in accordance with which the different groups of workers are monitored each month

  20. Solubility limited radionuclide transport through geologic media

    International Nuclear Information System (INIS)

    Muraoka, Susumu; Iwamoto, Fumio; Pigford, T.H.

    1980-11-01

    Prior analyses for the migration of radionuclides neglect solubility limits of resolved radionuclide in geologic media. But actually some of the actinides may appear in chemical forms of very low solubility. In the present report we have proposed the migration model with no decay parents in which concentration of radionuclide is limited in concentration of solubility in ground water. In addition, the analytical solutions of the space-time-dependent concentration are presented in the case of step release, band release and exponential release. (author)

  1. Soil - plant experimental radionuclide transfer factors

    International Nuclear Information System (INIS)

    Dobrin, R.I.; Dulama, C.N.; Toma, Al.

    2006-01-01

    Some experimental research was performed in our institute to assess site specific soil-plant transfer factors. A full characterization of an experimental site was done both from pedo-chemical and radiological point of view. Afterwards, a certain number of culture plants were grown on this site and the evolution of their radionuclide burden was then recorded. Using some soil amendments one performed a parallel experiment and the radionuclide root uptake was evaluated and recorded. Hence, transfer parameters were calculated and some conclusions were drawn concerning the influence of site specific conditions on the root uptake of radionuclides. (authors)

  2. DNA damage induced by radionuclide internal irradiation

    International Nuclear Information System (INIS)

    Cui Fengmei; Zhao Jingyong; Hong Chengjiao; Lao Qinhua; Wang Liuyi; Yang Shuqin

    2004-01-01

    Objective: To study the DNA damage of peripheral blood mononuclear cell (PBMC) in rats exposed to radionuclide internal irradiation. Methods: The radionuclides were injected into the rats and single cell get electrophoresis (SCGE) was performed to detect the length of DNA migration in the rat PBMC. Results: DNA migration in the rat PBMC increased with accumulative dose or dose-rate. It showed good relationship of dose vs. response and of dose-rate vs. response, both relationship could be described as linear models. Conclusion: Radionuclide internal irradiation could cause DNA damage in rat PBMC. (authors)

  3. Discordance of exercise thallium testing with coronary arteriography in patients with atypical presentations

    International Nuclear Information System (INIS)

    Bungo, M.W.; Leland, O.S. Jr.

    1983-01-01

    Eighty-one patients with diagnostically difficult clinical presentations suggesting coronary disease underwent symptom-limited maximal-exercise treadmill testing (ETT) and exercise radionuclide scanning with 201 Tl. Results of these tests were in agreement in only 47 percent of the cases. Either exercise thallium or ETT was positive in 94 percent of patients with disease. Among a population with a disease prevalence of 67 percent, agreement between exercise thallium an ETT predicted disease in 92 percent of instances or excluded disease in 82 percent of instances. Frequent discordance between these two tests in 53 percent of the cases unfortunately limits this usefulness

  4. Exercise and immunity

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007165.htm Exercise and immunity To use the sharing features on ... take a daily walk or follow a simple exercise routine a few times a week. Exercise helps ...

  5. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  6. Research progess on treatment of cancer with targeted radionuclide therapy

    International Nuclear Information System (INIS)

    Luo Jiawen; Zhang Caixia

    2008-01-01

    The new development and situation of targeted radionuclide therapy in oncology is described, which include radioimmunotherapy, peptide receptor radionuclide therapy, gene therapy and radionuclide labled chemotherapeutics therapy. The application research on labled carrier of those therapy is emphasized. Meanwhile, the research progess of indomethacin and its combined with targeted radionuclide therapy is also described. (authors)

  7. SR 97 - Radionuclide transport calculations

    Energy Technology Data Exchange (ETDEWEB)

    Lindgren, Maria [Kemakta Konsult AB, Stockholm (Sweden); Lindstroem, Fredrik [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)

    1999-12-01

    An essential component of a safety assessment is to calculate radionuclide release and dose consequences for different scenarios and cases. The SKB tools for such a quantitative assessment are used to calculate the maximum releases and doses for the hypothetical repository sites Aberg, Beberg and Ceberg for the initial canister defect scenario and also for the glacial melting case for Aberg. The reasonable cases, i.e. all parameters take reasonable values, results in maximum biosphere doses of 5x10{sup -8} Sv/yr for Aberg, 3x10{sup -8} Sv/yr for Beberg and 1x10{sup -8} Sv/yr for Ceberg for peat area. These doses lie significantly below 0.15 mSv/yr. (A dose of 0.15 mSv/yr for unit probability corresponds to the risk limit of 10{sup -5} per year for the most exposed individuals recommended in regulations.) The conclusion that the maximum risk would lie well below 10{sup -5} per year is also demonstrated by results from the probabilistic calculations, which directly assess the resulting risk by combining dose and probability estimates. The analyses indicate that the risk is 2x10{sup -5} Sv/yr for Aberg, 8x10{sup -7} Sv/yr for Beberg and 3x10{sup -8} Sv/yr for Ceberg. The analysis shows that the most important parameters in the near field are the number of defective canisters and the instant release fraction. The influence from varying one parameter never changes the doses as much as an order of magnitude. In the far field the most important uncertainties affecting release and retention are associated with permeability and connectivity of the fractures in the rock. These properties affect several parameters. Highly permeable and well connected fractures imply high groundwater fluxes and short groundwater travel times. Sparsely connected or highly variable fracture properties implies low flow wetted surface along migration paths. It should, however, be remembered that the far-field parameters have little importance if the near-field parameters take their reasonable

  8. SR 97 - Radionuclide transport calculations

    International Nuclear Information System (INIS)

    Lindgren, Maria; Lindstroem, Fredrik

    1999-12-01

    An essential component of a safety assessment is to calculate radionuclide release and dose consequences for different scenarios and cases. The SKB tools for such a quantitative assessment are used to calculate the maximum releases and doses for the hypothetical repository sites Aberg, Beberg and Ceberg for the initial canister defect scenario and also for the glacial melting case for Aberg. The reasonable cases, i.e. all parameters take reasonable values, results in maximum biosphere doses of 5x10 -8 Sv/yr for Aberg, 3x10 -8 Sv/yr for Beberg and 1x10 -8 Sv/yr for Ceberg for peat area. These doses lie significantly below 0.15 mSv/yr. (A dose of 0.15 mSv/yr for unit probability corresponds to the risk limit of 10 -5 per year for the most exposed individuals recommended in regulations.) The conclusion that the maximum risk would lie well below 10 -5 per year is also demonstrated by results from the probabilistic calculations, which directly assess the resulting risk by combining dose and probability estimates. The analyses indicate that the risk is 2x10 -5 Sv/yr for Aberg, 8x10 -7 Sv/yr for Beberg and 3x10 -8 Sv/yr for Ceberg. The analysis shows that the most important parameters in the near field are the number of defective canisters and the instant release fraction. The influence from varying one parameter never changes the doses as much as an order of magnitude. In the far field the most important uncertainties affecting release and retention are associated with permeability and connectivity of the fractures in the rock. These properties affect several parameters. Highly permeable and well connected fractures imply high groundwater fluxes and short groundwater travel times. Sparsely connected or highly variable fracture properties implies low flow wetted surface along migration paths. It should, however, be remembered that the far-field parameters have little importance if the near-field parameters take their reasonable values. In that case almost all

  9. Radionuclide imaging of musculoskeletal infection

    Directory of Open Access Journals (Sweden)

    Christopher J. Palestro

    2007-09-01

    Full Text Available Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of "complicating osteomyelitis" such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose.Estudos através de imagens com o uso de radionuclídeos são rotineiramente usadas para avaliar pacientes suspeitos de terem infecção músculo-esquelética. A imagem óssea em tridimensional é facilmente avaliável, relativamente de baixo custo, e muito precisa na localização de alterações ósseas. Imagem com leucócito marcado poderia ser usada nos casos de "osteomielite com complicações" tais como infecção prostética articular. Esse teste também é útil na não suspeita clinica de osteomielite associada ao pé diabético tanto quanto nas junções neuropáticas. É sempre necessário, por outro lado, realizar imagem complementar da medula óssea para aumentar a precisão da imagem com leucócito marcado. Em contraste com outras regiões no esqueleto, imagem com leucócito marcado não é útil para diagnosticar osteomielite da coluna vertebral. Até agora, o gálio é o radionuclídeo preferido para

  10. Determination of alpha radionuclides in fish

    International Nuclear Information System (INIS)

    Pernicka, L.; Matel, L.; Rosskopfova, O.

    2002-01-01

    The specific activity of alpha radionuclides was determined in biological samples. The biological samples were chosen in kinds of fish, concretely mackerels, herrings and haddocks. Experimental data were presented on the poster

  11. Phytoremediation of soils contaminated with radionuclides

    International Nuclear Information System (INIS)

    Yamaguchi, Isamu

    2004-01-01

    Aiming at efficient phytoremediation of soils contaminated with radionuclides, we examined the effect of soil microbes on the uptake ability of plants using the multitracer technique to find that tomato rhizofungi in Fusarium spp. can stimulate the uptake of 85 Sr and 137 Cs by the plants. The synergic effect of a nonpathogenic strain of F. oxysporum on the uptake of radionuclides by plants proved to be enhanced by introducing a phytochelatin synthase gene into the fungus. Since soil contamination by radionuclides is still an unsolved problem in many parts of the world. Studies on phytoremediation of polluted soil environment will be important for developing effective strategies and devising adequate techniques to reduce human risks caused by food contamination of radionuclides. (author)

  12. Radiation safety requirements for radionuclide laboratories

    International Nuclear Information System (INIS)

    2000-01-01

    The guide lays down the requirements for laboratories and storage rooms in which radioactive substances are used or stored as unsealed sources. In addition, some general instructions concerning work in radionuclide laboratories are set out

  13. Natural and anthropogenic radionuclides in the environment

    International Nuclear Information System (INIS)

    Hille, R.

    1984-01-01

    A survey is given on the actual knowledge about occurence and environmental relevancy of the most important radionuclides from natural and anthropogenic origin. The contribution of AGF installation is emphasized. (orig.) [de

  14. Application of radionuclides in nuclear technology

    International Nuclear Information System (INIS)

    Boeck, H.

    1983-07-01

    Four main applications of radionuclides in nuclear technology are presented which are level-, density- and thickness gauging and moisture determination. Each method is surveyed for its general principle, various designs, accuracy, errors and practical designs. (Author)

  15. Transfer of radionuclides into human milk

    International Nuclear Information System (INIS)

    Steiner, M.; Wirth, E.

    1998-01-01

    Up until now the potential radiation exposure to breast-fed babies due to contaminated human milk has not been taken into account, when deriving international limit values and reference levels for radionuclides in foodstuffs, in air at monitored work places or for exposures in the medical field. It was the aim of the research project 'Transfer of radionuclides into human milk' to quantify the transfer of incorporated radionuclides into mother's milk, and develop simple models to estimate the radiation exposure of babies through the ingestion of human milk. The study focused on considerations of the radiation exposure due to the ingestion of contaminated foodstuffs by the mother, the inhalation of radionuclides at monitored work places, and the administration of radiopharmaceuticals to breast-feeding mothers. The blocking of infant thyroid glands by stable iodine in the case of accidental releases of radioiodine was considered as well. (orig.) [de

  16. Radiation safety requirements for radionuclide laboratories

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The guide lays down the requirements for laboratories and storage rooms in which radioactive substances are used or stored as unsealed sources. In addition, some general instructions concerning work in radionuclide laboratories are set out.

  17. Radionuclide transport in a single fissure

    International Nuclear Information System (INIS)

    Eriksen, T.E.

    1984-01-01

    Radionuclide migration has been studied in natural fissures running parallel to the axes of granitic drill cores. A short pulse of radionuclide solution was injected at one end of the fissure and the temporal change in radionuclide concentration of the eluate measured. At the end of each experiment the fissure was opened and the radionuclide distribution on the fissure surfaces measured. The retardation of 241 Am(III) at pH 8.2 as well as the variation in 235 Np(V) retardation with pH are found to be in good agreement with K d-values obtained in batch experiments. The reduction of (TcO - 4 ) to Tc(IV) leads as expected to increasing retardation.(author)

  18. Metabolic transformation of radionuclides in marine organisms

    International Nuclear Information System (INIS)

    Koyanagi, Taku

    1987-01-01

    Physico-chemical form of radionuclides is one of the important factors governing the concentration by marine organisms, whereas biological activities affect the existing states of radionuclides especially in coastal waters. Radioiodine in the form of iodate which is predominant species in seawater is reduced to iodide ion by biological activities and concentration factor of iodide is an order of magnitude higher than those of iodate. Extremely high accumulation of transition elements, actinides, or natural radionuclides in branchial heart of octopus is explained by the fuction of adenochrome, a glandular pigment in the organ as a natural complexing agent, and similar metal-binding proteins with relatively low molecular weight have been found in various marine invertebrates. High accumulation of some elements also found in mollusk kidney is considered to be caused by the intracellular concretions composed of calcium phosphate. All these biological processes suggest the significance of further investigations on metabolic transformation of radionuclides in marine organisms. (author)

  19. Relating β+ radionuclides' properties by order theory

    International Nuclear Information System (INIS)

    Quintero, N.Y.; Guillermo Restrepo; Cohen, I.M.; Universidad Tecnologica Nacional, Buenos Aires

    2013-01-01

    We studied 27 β + radionuclides taking into account some of their variants encoding information of their production, such as integral yield, threshold energy and energy of projectiles used to generate them; these radionuclides are of current use in clinical diagnostic imaging by positron emission tomography (PET). The study was conducted based on physical, physico-chemical, nuclear, dosimetric and quantum properties, which characterise the β + radionuclides selected, with the aim of finding meaningful relationships among them. In order to accomplish this objective the mathematical methodology known as formal concept analysis was employed. We obtained a set of logical assertions (rules) classified as implications and associations, for the set of β + radionuclides considered. Some of them show that low mass defect is related to high and medium values of maximum β + energy, and with even parity and low mean lives; all these parameters are associated to the dose received by a patient subjected to a PET analysis. (author)

  20. Behaviour of the radionuclides in the environment

    International Nuclear Information System (INIS)

    Lauria, Dejanira da Costa

    2007-01-01

    This chapter approaches the behaviour of radionuclides in the environment, the isotopes of the natural radioactive series, some aspects of the isotope behaviour on the environment and fission and activation radioactive isotopes