WorldWideScience

Sample records for exercise gas exchange

  1. Exercise: Kinetic considerations for gas exchange.

    Science.gov (United States)

    Rossiter, Harry B

    2011-01-01

    The activities of daily living typically occur at metabolic rates below the maximum rate of aerobic energy production. Such activity is characteristic of the nonsteady state, where energy demands, and consequential physiological responses, are in constant flux. The dynamics of the integrated physiological processes during these activities determine the degree to which exercise can be supported through rates of O₂ utilization and CO₂ clearance appropriate for their demands and, as such, provide a physiological framework for the notion of exercise intensity. The rate at which O₂ exchange responds to meet the changing energy demands of exercise--its kinetics--is dependent on the ability of the pulmonary, circulatory, and muscle bioenergetic systems to respond appropriately. Slow response kinetics in pulmonary O₂ uptake predispose toward a greater necessity for substrate-level energy supply, processes that are limited in their capacity, challenge system homeostasis and hence contribute to exercise intolerance. This review provides a physiological systems perspective of pulmonary gas exchange kinetics: from an integrative view on the control of muscle oxygen consumption kinetics to the dissociation of cellular respiration from its pulmonary expression by the circulatory dynamics and the gas capacitance of the lungs, blood, and tissues. The intensity dependence of gas exchange kinetics is discussed in relation to constant, intermittent, and ramped work rate changes. The influence of heterogeneity in the kinetic matching of O₂ delivery to utilization is presented in reference to exercise tolerance in endurance-trained athletes, the elderly, and patients with chronic heart or lung disease. © 2011 American Physiological Society.

  2. The impact of gas exchange measurement during exercise in pulmonary sarcoidosis.

    Science.gov (United States)

    Kollert, Florian; Geck, Barbara; Suchy, Rolf; Jörres, Rudolf A; Arzt, Michael; Heidinger, Dominic; Hamer, Okka W; Prasse, Antje; Müller-Quernheim, Joachim; Pfeifer, Michael; Budweiser, Stephan

    2011-01-01

    Pulmonary sarcoidosis shows a remarkable heterogeneity of phenotypes ranging from bihilar lymphadenopathy to progressive fibrosis. Individual disease assessment is demanding and requires sensible, practical measures. We tested whether gas exchange measurements during exercise reflects disease activity and clinical course in sarcoidosis. In 149 patients with proven pulmonary sarcoidosis the alveolar-arterial oxygen pressure gradient (P(A-a)O(2)) during exercise was assessed and compared with chest X-ray typing, pulmonary function, single breath-diffusing capacity for carbon monoxide (DL(CO)), serological markers, cell composition of bronchoalveolar lavage fluid (BALF) and clinical course. Patients were categorized according to thresholds of P(A-a)O(2) during exercise. Chest X-ray typing, pulmonary function, DL(CO) and the need for immunosuppressive treatment differed between the disease categories based on P(A-a)O(2) during exercise (p 1 year), but not DL(CO). About 50% (n = 75) of the study population showed a normal spirometry. Even in this subgroup 23% had an impaired gas exchange during exercise, which correlated with chest X-ray types (p < 0.0001) and the need for immunosuppressive treatment (p < 0.005). Impaired gas exchange during exercise reflects disease activity and its extent and is associated with a prolonged need for immunosuppressive treatment during follow-up in patients with pulmonary sarcoidosis. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Gas exchange kinetics following concentric-eccentric isokinetic arm and leg exercise.

    Science.gov (United States)

    Drescher, U; Mookerjee, S; Steegmanns, A; Knicker, A; Hoffmann, U

    2017-06-01

    To evaluate the effects of exercise velocity (60, 150, 240deg∙s -1 ) and muscle mass (arm vs leg) on changes in gas exchange and arterio-venous oxygen content difference (avDO 2 ) following high-intensity concentric-eccentric isokinetic exercise. Fourteen subjects (26.9±3.1years) performed a 3×20-repetition isokinetic exercise protocol. Recovery beat-to-beat cardiac output (CO) and breath-by-breath gas exchange were recorded to determine post-exercise half-time (t 1/2 ) for oxygen uptake (V˙O 2 pulm), carbon dioxide output (V˙CO 2 pulm), and ventilation (V˙ E ). Significant differences of the t 1/2 values were identified between 60 and 150deg∙s -1 . Significant differences in the t 1/2 values were observed between V˙O 2 pulm and V˙CO 2 pulm and between V˙CO 2 pulm and V˙ E . The time to attain the first avDO 2 -peak showed significant differences between arm and leg exercise. The present study illustrates, that V˙O 2 pulm kinetics are distorted due to non-linear CO dynamics. Therefore, it has to be taken into account, that V˙O 2 pulm may not be a valuable surrogate for muscular oxygen uptake kinetics in the recovery phases. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise.

    OpenAIRE

    Sridhar, M K; Carter, R; Moran, F; Banham, S W

    1993-01-01

    BACKGROUND--Accurate and reliable measurement of gas exchange during exercise has traditionally involved arterial cannulation. Non-invasive devices to estimate arterial oxygen (O2) and carbon dioxide (CO2) tensions are now available. A method has been devised and evaluated for measuring gas exchange during exercise with a combined transcutaneous O2 and CO2 electrode. METHODS--Symptom limited exercise tests were carried out in 24 patients reporting effort intolerance and breathlessness. Exerci...

  5. Pulmonary hypertension in patients with idiopathic pulmonary fibrosis - the predictive value of exercise capacity and gas exchange efficiency.

    Directory of Open Access Journals (Sweden)

    Sven Gläser

    Full Text Available Exercise capacity and survival of patients with IPF is potentially impaired by pulmonary hypertension. This study aims to investigate diagnostic and prognostic properties of gas exchange during exercise and lung function in IPF patients with or without pulmonary hypertension. In a multicentre setting, patients with IPF underwent right heart catheterization, cardiopulmonary exercise and lung function testing during their initial evaluation. Mortality follow up was evaluated. Seventy-three of 135 patients [82 males; median age of 64 (56; 72 years] with IPF had pulmonary hypertension as assessed by right heart catheterization [median mean pulmonary arterial pressure 34 (27; 43 mmHg]. The presence of pulmonary hypertension was best predicted by gas exchange efficiency for carbon dioxide (cut off ≥152% predicted; area under the curve 0.94 and peak oxygen uptake (≤56% predicted; 0.83, followed by diffusing capacity. Resting lung volumes did not predict pulmonary hypertension. Survival was best predicted by the presence of pulmonary hypertension, followed by peak oxygen uptake [HR 0.96 (0.93; 0.98]. Pulmonary hypertension in IPF patients is best predicted by gas exchange efficiency during exercise and peak oxygen uptake. In addition to invasively measured pulmonary arterial pressure, oxygen uptake at peak exercise predicts survival in this patient population.

  6. Alveolar gas exchange and tissue oxygenation during incremental treadmill exercise, and their associations with blood O2 carrying capacity

    Directory of Open Access Journals (Sweden)

    Antti-Pekka E. Rissanen

    2012-07-01

    Full Text Available The magnitude and timing of oxygenation responses in highly active leg muscle, less active arm muscle, and cerebral tissue, have not been studied with simultaneous alveolar gas exchange measurement during incremental treadmill exercise. Nor is it known, if blood O2 carrying capacity affects the tissue-specific oxygenation responses. Thus, we investigated alveolar gas exchange and tissue (m. vastus lateralis, m. biceps brachii, cerebral cortex oxygenation during incremental treadmill exercise until volitional fatigue, and their associations with blood O2 carrying capacity in 22 healthy men. Alveolar gas exchange was measured, and near-infrared spectroscopy (NIRS was used to monitor relative concentration changes in oxy- (Δ[O2Hb], deoxy- (Δ[HHb] and total hemoglobin (Δ[tHb], and tissue saturation index (TSI. NIRS inflection points (NIP, reflecting changes in tissue-specific oxygenation, were determined and their coincidence with ventilatory thresholds (anaerobic threshold (AT, respiratory compensation point (RC; V-slope method was examined. Blood O2 carrying capacity (total hemoglobin mass (tHb-mass was determined with the CO-rebreathing method. In all tissues, NIPs coincided with AT, whereas RC was followed by NIPs. High tHb-mass associated with leg muscle deoxygenation at peak exercise (e.g., Δ[HHb] from baseline walking to peak exercise vs. tHb-mass: r = 0.64, p < 0.01, but not with arm muscle- or cerebral deoxygenation. In conclusion, regional tissue oxygenation was characterized by inflection points, and tissue oxygenation in relation to alveolar gas exchange during incremental treadmill exercise resembled previous findings made during incremental cycling. It was also found out, that O2 delivery to less active m. biceps brachii may be limited by an accelerated increase in ventilation at high running intensities. In addition, high capacity for blood O2 carrying was associated with a high level of m. vastus lateralis deoxygenation at peak

  7. Is pulmonary gas exchange during exercise in hypoxia impaired with the increase of cardiac output?

    DEFF Research Database (Denmark)

    Calbet, J.A.; Robach, P.; Lundby, C.

    2008-01-01

    During exercise in humans, the alveolar-arterial O(2) tension difference ((A-a)DO(2)) increases with exercise intensity and is an important factor determining the absolute level of oxygen binding to hemoglobin and therefore the level of systemic oxygen transport. During exercise in hypoxia, the (A......-a)DO(2) is accentuated. Using the multiple inert gas elimination technique it has been shown that during exercise in acute hypoxia the contribution of ventilation-perfusion inequality to (A-a)DO(2) is rather small and in the absence of pulmonary edema intrapulmonary shunts can be ruled out. This implies...... that the main mechanism limiting pulmonary gas exchange is diffusion limitation. It is presumed that an elevation of cardiac output during exercise in acute hypoxia should increase the (A-a)DO(2). However, no studies have examined how variations in cardiac output independently affect pulmonary diffusion...

  8. Preoperative gender differences in pulmonary gas exchange in morbidly obese subjects.

    Science.gov (United States)

    Zavorsky, Gerald S; Christou, Nicolas V; Kim, Do Jun; Carli, Franco; Mayo, Nancy E

    2008-12-01

    Morbidly obese men may have poorer pulmonary gas exchange compared to morbidly obese women (see Zavorsky et al., Chest 131:362-367, 2007). The purpose was to compare pulmonary gas exchange in morbidly obese men and women at rest and throughout exercise. Twenty-five women (age=38+/-10 years, 164+/-7 cm, body mass index or BMI = 51+/-7 kg/m(2), peak oxygen consumption or VO(2peak)=2.0+/-0.4 l/min) and 17 men (age=43+/-9 years, 178+/-7 cm, BMI=50+/-10 kg/m(2), VO(2peak)=2.6+/-0.8 l/min) were recruited to perform a graded exercise test on a cycle ergometer with temperature-corrected arterial blood-gas samples taken at rest and every minute of exercise, including peak exercise. At rest, women were 98% predicted for pulmonary diffusion compared to 88% predicted in men. At rest, women had better pulmonary gas exchange compared to the men which was related to women having a lower waist-to-hip ratio (WHR; por=25 mmHg) at peak exercise, but 75% of the subjects showed inadequate compensatory hyperventilation at peak exercise (arterial carbon dioxide pressure >35 mmHg), and both were not different between genders. At rest, morbidly obese men have poorer pulmonary gas exchange and pulmonary diffusion compared to morbidly obese women. The better gas exchange in women is related to the lower WHR in the women. During exercise, few subjects showed disturbances in pulmonary gas exchange despite demonstrating poor compensatory hyperventilation at peak exercise.

  9. Influence of inhaled nitric oxide on gas exchange during normoxic and hypoxic exercise in highly trained cyclists.

    Science.gov (United States)

    Sheel, A W; Edwards, M R; Hunte, G S; McKenzie, D C

    2001-03-01

    This study tested the effects of inhaled nitric oxide [NO; 20 parts per million (ppm)] during normoxic and hypoxic (fraction of inspired O(2) = 14%) exercise on gas exchange in athletes with exercise-induced hypoxemia. Trained male cyclists (n = 7) performed two cycle tests to exhaustion to determine maximal O(2) consumption (VO(2 max)) and arterial oxyhemoglobin saturation (Sa(O(2)), Ohmeda Biox ear oximeter) under normoxic (VO(2 max) = 4.88 +/- 0.43 l/min and Sa(O(2)) = 90.2 +/- 0.9, means +/- SD) and hypoxic (VO(2 max) = 4.24 +/- 0.49 l/min and Sa(O(2)) = 75.5 +/- 4.5) conditions. On a third occasion, subjects performed four 5-min cycle tests, each separated by 1 h at their respective VO(2 max), under randomly assigned conditions: normoxia (N), normoxia + NO (N/NO), hypoxia (H), and hypoxia + NO (H/NO). Gas exchange, heart rate, and metabolic parameters were determined during each condition. Arterial blood was drawn at rest and at each minute of the 5-min test. Arterial PO(2) (Pa(O(2))), arterial PCO(2), and Sa(O(2)) were determined, and the alveolar-arterial difference for PO(2) (A-aDO(2)) was calculated. Measurements of Pa(O(2)) and Sa(O(2)) were significantly lower and A-aDO(2) was widened during exercise compared with rest for all conditions (P 0.05). We conclude that inhalation of 20 ppm NO during normoxic and hypoxic exercise has no effect on gas exchange in highly trained cyclists.

  10. Exercise on-transition uncoupling of ventilatory, gas exchange and cardiac hemodynamic kinetics accompany pulmonary oxygen stores depletion to impact exercise intolerance in human heart failure.

    Science.gov (United States)

    Van Iterson, E H; Smith, J R; Olson, T P

    2018-03-25

    In contrast to knowledge that heart failure (HF) patients demonstrate peak exercise uncoupling across ventilation, gas exchange and cardiac haemodynamics, whether this dyssynchrony follows that at the exercise on-transition is unclear. This study tested whether exercise on-transition temporal lag for ventilation relative to gas exchange and oxygen pulse (O 2 pulse) couples with effects from abnormal pulmonary gaseous oxygen store (O 2store ) contributions to V˙O 2 to interdependently precipitate persistently elevated ventilatory demand and low oxidative metabolic capacity in HF. Beat-to-beat HR and breath-to-breath ventilation and gas exchange were continuously acquired in HF (N = 9, ejection fraction = 30 ± 9%) and matched controls (N = 10) during square-wave ergometry at 60% V˙O 2peak (46 ± 14 vs 125 ± 54-W, P < .001). Temporal responses across V˙ E , V˙O 2 and O 2 pulse were assessed for the exercise on-transition using single exponential model Phase II on-kinetic time constants (τ = time to reach 63% steady-state rise). Breath-to-breath gas fractions and respiratory flows were used to determine O 2stores . HF vs controls: τ for V˙ E (137 ± 93 vs 74 ± 40-seconds, P = .03), V˙O 2 (60 ± 40 vs 23 ± 5-seconds, P = .03) and O 2 pulse (28 ± 18 vs 23 ± 15-seconds, P = .59). Within HF, τ for V˙ E differed from O 2 pulse (P < .02), but not V˙O 2 . Exercise V˙ E rise (workload indexed) differed in HF vs controls (545 ± 139 vs 309 ± 88-mL min -1 W -1 , P < .001). Exercise on-transition O 2store depletion in HF exceeded controls, generally persisting to end-exercise. These data suggest HF demonstrated exercise on-transition O 2store depletion (high O 2store contribution to V˙O 2 ) coupled with dyssynchronous V˙ E , V˙O 2 and O 2 pulse kinetics-not attributable to prolonged cardiac haemodynamics. Persistent high ventilatory demand and low oxidative metabolic capacity in HF may be precipitated by physiological uncoupling occurring within the exercise

  11. Do We Need Exercise Tests to Detect Gas Exchange Impairment in Fibrotic Idiopathic Interstitial Pneumonias?

    Directory of Open Access Journals (Sweden)

    Benoit Wallaert

    2012-01-01

    Full Text Available In patients with fibrotic idiopathic interstitial pneumonia (f-IIP, the diffusing capacity for carbon monoxide (DLCO has been used to predict abnormal gas exchange in the lung. However, abnormal values for arterial blood gases during exercise are likely to be the most sensitive manifestations of lung disease. The aim of this study was to compare DLCO, resting PaO2, P(A-aO2 at cardiopulmonary exercise testing peak, and oxygen desaturation during a 6-min walk test (6MWT. Results were obtained in 121 patients with idiopathic pulmonary fibrosis (IPF, n=88 and fibrotic nonspecific interstitial pneumonias (NSIP, n=33. All but 3 patients (97.5% had low DLCO values (35 mmHg and 100 (83% demonstrated significant oxygen desaturation during 6MWT (>4%. Interestingly 27 patients had low DLCO and normal P(A-aO2, peak and/or no desaturation during the 6MWT. The 3 patients with normal DLCO also had normal PaO2, normal P(A-aO2, peak, and normal oxygen saturation during 6MWT. Our results demonstrate that in fibrotic IIP, DLCO better defines impairment of pulmonary gas exchange than resting PaO2, exercise P(A-aO2, peak, or 6MWT SpO2.

  12. Altered gas-exchange at peak exercise in obese adolescents: implications for verification of effort during cardiopulmonary exercise testing.

    Science.gov (United States)

    Marinus, Nastasia; Bervoets, Liene; Massa, Guy; Verboven, Kenneth; Stevens, An; Takken, Tim; Hansen, Dominique

    2017-12-01

    Cardiopulmonary exercise testing is advised ahead of exercise intervention in obese adolescents to assess medical safety of exercise and physical fitness. Optimal validity and reliability of test results are required to identify maximal exercise effort. As fat oxidation during exercise is disturbed in obese individuals, it remains an unresolved methodological issue whether the respiratory gas exchange ratio (RER) is a valid marker for maximal effort during exercise testing in this population. RER during maximal exercise testing (RERpeak), and RER trajectories, was compared between obese and lean adolescents and relationships between RERpeak, RER slope and subject characteristics (age, gender, Body Mass Index [BMI], Tanner stage, physical activity level) were explored. Thirty-four obese (BMI: 35.1±5.1 kg/m²) and 18 lean (BMI: 18.8±1.9 kg/m²) adolescents (aged 12-18 years) performed a maximal cardiopulmonary exercise test on bike, with comparison of oxygen uptake (VO2), heart rate (HR), expiratory volume (VE), carbon dioxide output (VCO2), and cycling power output (W). RERpeak (1.09±0.06 vs. 1.14±0.06 in obese vs. lean adolescents, respectively) and RER slope (0.03±0.01 vs. 0.05±0.01 per 10% increase in VO2, in obese vs. lean adolescents, respectively) was significantly lower in obese adolescents, and independently related to BMI (Pexercise testing in this population.

  13. Gas exchange during exercise in different evolutional stages of chronic Chagas' heart disease

    Directory of Open Access Journals (Sweden)

    Fátima Palha de Oliveira

    2000-12-01

    Full Text Available OBJECTIVE: To compare gas exchange at rest and during exercise in patients with chronic Chagas' heart disease grouped according to the Los Andes clinical/hemodynamic classification. METHODS: We studied 15 healthy volunteers and 52 patients grouped according to the Los Andes clinical/hemodynamic classification as follows: 17 patients in group IA (normal electrocardiogram/echocardiogram, 9 patients in group IB (normal electrocardiogram and abnormal echocardiogram, 14 patients in group II (abnormal electrocardiogram/echocardiogram, without congestive heart failure, and 12 patients in group III (abnormal electrocardiogram/echocardiogram with congestive heart failure. The following variables were analyzed: oxygen consumption (V O2, carbon dioxide production (V CO2, gas exchange rate (R, inspiratory current volume (V IC, expiratory current volume (V EC, respiratory frequency, minute volume (V E, heart rate (HR, maximum load, O2 pulse, and ventilatory anaerobic threshold (AT. RESULTS: When compared with the healthy group, patients in groups II and III showed significant changes in the following variables: V O2peak, V CO2peak, V ICpeak, V ECpeak, E, HR, and maximum load. Group IA showed significantly better results for these same variables as compared with group III. CONCLUSION: The functional capacity of patients in the initial phase of chronic Chagas' heart disease is higher than that of patients in an advanced phase and shows a decrease that follows the loss in cardiac-hemodynamic performance.

  14. Gas exchange during exercise in different evolutional stages of chronic Chagas' heart disease.

    Science.gov (United States)

    Oliveira, F P; Pedrosa, R C; Giannella-Neto, A

    2000-12-01

    To compare gas exchange at rest and during exercise in patients with chronic Chagas' heart disease grouped according to the Los Andes clinical hemodynamic classification. We studied 15 healthy volunteers and 52 patients grouped according to the Los Andes clinical and hemodynamic classification as follows: 17 patients in group IA (normal electrocardiogram and echocardiogram), 9 patients in group IB (normal electrocardiogram and abnormal echocardiogram), 14 patients in group II (abnormal electrocardiogram and echocardiogram, without congestive heart failure), and 12 patients in group III (abnormal electrocardiogram and echocardiogram with congestive heart failure). The following variables were analyzed: oxygen consumption (V O2), carbon dioxide production (V CO2), gas exchange rate (R), inspiratory current volume (V IC), expiratory current volume (V EC), respiratory frequency, minute volume (V E), heart rate (HR), maximum load, O2 pulse, and ventilatory anaerobic threshold (AT). When compared with the healthy group, patients in groups II and III showed significant changes in the following variables: V O2 peak, V CO2 peak, V IC peak, V EC peak, E, HR, and maximum load. Group IA showed significantly better results for these same variables as compared with group III. The functional capacity of patients in the initial phase of chronic Chagas' heart disease is higher than that of patients in an advanced phase and shows a decrease that follows the loss in cardiac-hemodynamic performance.

  15. Influence of exercise modality on agreement between gas exchange and heart rate variability thresholds.

    Science.gov (United States)

    Cunha, F A; Montenegro, R A; Midgley, A W; Vasconcellos, F; Soares, P P; Farinatti, P

    2014-08-01

    The main purpose of this study was to investigate the level of agreement between the gas exchange threshold (GET) and heart rate variability threshold (HRVT) during maximal cardiopulmonary exercise testing (CPET) using three different exercise modalities. A further aim was to establish whether there was a 1:1 relationship between the percentage heart rate reserve (%HRR) and percentage oxygen uptake reserve (%VO2 R) at intensities corresponding to GET and HRVT. Sixteen apparently healthy men 17 to 28 years of age performed three maximal CPETs (cycling, walking, and running). Mean heart rate and VO2 at GET and HRVT were 16 bpm (P0.05). There was a strong relationship between GET and HRVT, with R2 ranging from 0.69 to 0.90. A 1:1 relationship between %HRR and % VO2 R was not observed at GET and HRVT. The %HRR was higher during cycling (GET mean difference=7%; HRVT mean difference=11%; both P<0.001), walking (GET mean difference=13%; HRVT mean difference=13%; both P<0.001), or running (GET mean difference=11%; HRVT mean difference=10%; both P<0.001). Therefore, using HRVT to prescribe aerobic exercise intensity appears to be valid. However, to assume a 1:1 relationship between %HRR and % VO2 R at HRVT would probably result in overestimation of the energy expenditure during the bout of exercise.

  16. Importance of ventricular rate after mode switching during low intensity exercise as assessed by clinical symptoms and ventilatory gas exchange.

    Science.gov (United States)

    Brunner-La Rocca, H P; Rickli, H; Weilenmann, D; Duru, F; Candinas, R

    2000-01-01

    Automatic mode switching from DDD(R) to DDI(R) or VVI(R) pacing modes has improved dual chamber pacing in patients at high risk for supraventricular tachyarrhythmias. However, little is known about the effect of ventricular pacing rate adaptation after mode switching. We conducted a single-blinded, crossover study in 15 patients (58 +/- 21 years) with a DDD pacemaker who had AV block and normal sinus node function to investigate the influence of pacing rate adaptation to intrinsic heart rate during low intensity exercise. Patients performed two tests (A/B) of low intensity treadmill exercise (0.5 W/kg) in randomized order. They initially walked for 6 minutes while paced in DDD mode. The pacing mode was then switched to VVI with a pacing rate of either 70 beats/min (test A) or matched to the intrinsic heart rate (95 +/- 11 beats/min test B). Respiratory gas exchange variables were determined and patients classified the effort before and after mode switching on a Borg scale from 6 to 20. Percentage changes of respiratory gas exchange measurements were significantly larger (O2 consumption: -8.2 +/- 5.0% vs. -0.6 +/- 7.2%; ventilatory equivalent of CO2 exhalation: 5.3 +/- 4.9% vs. 1.5 +/- 4.3%; respiratory exchange ratio: 7.0 +/- 2.2% vs. 3.5 +/- 3.0%; end-tidal CO2: -5.7 +/- 2.9% vs. -1.8 +/- 2.7%; all P rate unadjusted than after adjusted mode switching. Mode switching from DDD to VVI pacing is better tolerated and gas exchange measurements are less influenced if ventricular pacing rate is adjusted to the level of physical activity. Thus, pacing rate adjustment should be considered as part of automatic mode switch algorithms.

  17. Hibernation and gas exchange.

    Science.gov (United States)

    Milsom, William K; Jackson, Donald C

    2011-01-01

    Hibernation in endotherms and ectotherms is characterized by an energy-conserving metabolic depression due to low body temperatures and poorly understood temperature-independent mechanisms. Rates of gas exchange are correspondly reduced. In hibernating mammals, ventilation falls even more than metabolic rate leading to a relative respiratory acidosis that may contribute to metabolic depression. Breathing in some mammals becomes episodic and in some small mammals significant apneic gas exchange may occur by passive diffusion via airways or skin. In ectothermic vertebrates, extrapulmonary gas exchange predominates and in reptiles and amphibians hibernating underwater accounts for all gas exchange. In aerated water diffusive exchange permits amphibians and many species of turtles to remain fully aerobic, but hypoxic conditions can challenge many of these animals. Oxygen uptake into blood in both endotherms and ectotherms is enhanced by increased affinity of hemoglobin for O₂ at low temperature. Regulation of gas exchange in hibernating mammals is predominately linked to CO₂/pH, and in episodic breathers, control is principally directed at the duration of the apneic period. Control in submerged hibernating ectotherms is poorly understood, although skin-diffusing capacity may increase under hypoxic conditions. In aerated water blood pH of frogs and turtles either adheres to alphastat regulation (pH ∼8.0) or may even exhibit respiratory alkalosis. Arousal in hibernating mammals leads to restoration of euthermic temperature, metabolic rate, and gas exchange and occurs periodically even as ambient temperatures remain low, whereas body temperature, metabolic rate, and gas exchange of hibernating ectotherms are tightly linked to ambient temperature. © 2011 American Physiological Society.

  18. Influence of the incremental step size in work rate on exercise response and gas exchange in patients with pulmonary hypertension.

    Science.gov (United States)

    Gläser, Sven; Lodziewski, Sven; Koch, Beate; Opitz, Christian F; Völzke, Henry; Ewert, Ralf

    2008-02-23

    Cardiopulmonary exercise testing (CPET) has become increasingly important as a routine procedure in daily clinical work. So far, it is generally accepted that an individualized exercise protocol with exercise duration of 6 to 12 minutes is preferable to assess maximal exercise performance. The aim of this study was to compare an individualized NYHA adapted exercise protocol with a fixed standard protocol in patients with severe pulmonary arterial hypertension. Twenty-two patients (17 female, 5 male; mean age 49 +/- 14 yrs) underwent symptom limited CPET on a bicycle. On two consecutive days each subject performed a stepwise CPET according to a modified Jones protocol (16 Watt per minute stages) as well as an individualized NYHA adapted protocol with 5 or 10 Watt/min stages in a randomized order. Oxygen uptake at peak exercise (peakVO2) and anaerobic threshold (VO2AT), maximal ventilation (VE), breathing reserve (VE/MVV), ventilatory efficiency (VE vs. VCO2 slope), exercise time, maximal power and work rate were assessed and compared between both protocols. Comparing both, adapted NYHA protocol and standardized Jones protocol, we found significant differences in maximal power (56.7 +/- 19 W vs. 74 +/- 18 W; p rate, VE, VE/MVV, peakVO2, VO2AT and VE vs. VCO2 slope. Variations of incremental step size during CPET significantly affect exercise time and maximal power, whereas relevant parameters for clinical judgement and prognosis such as oxygen uptake, ventilation and ventilatory efficiency remain unchanged. These findings have practical implications for the exercise evaluation of patients with pulmonary hypertension. To reach maximal results for ventilation, oxygen uptake and gas exchange an individualization of incremental step size appears not to be mandatory.

  19. Lung Structure and the Intrinsic Challenges of Gas Exchange.

    Science.gov (United States)

    Hsia, Connie C W; Hyde, Dallas M; Weibel, Ewald R

    2016-03-15

    Structural and functional complexities of the mammalian lung evolved to meet a unique set of challenges, namely, the provision of efficient delivery of inspired air to all lung units within a confined thoracic space, to build a large gas exchange surface associated with minimal barrier thickness and a microvascular network to accommodate the entire right ventricular cardiac output while withstanding cyclic mechanical stresses that increase several folds from rest to exercise. Intricate regulatory mechanisms at every level ensure that the dynamic capacities of ventilation, perfusion, diffusion, and chemical binding to hemoglobin are commensurate with usual metabolic demands and periodic extreme needs for activity and survival. This article reviews the structural design of mammalian and human lung, its functional challenges, limitations, and potential for adaptation. We discuss (i) the evolutionary origin of alveolar lungs and its advantages and compromises, (ii) structural determinants of alveolar gas exchange, including architecture of conducting bronchovascular trees that converge in gas exchange units, (iii) the challenges of matching ventilation, perfusion, and diffusion and tissue-erythrocyte and thoracopulmonary interactions. The notion of erythrocytes as an integral component of the gas exchanger is emphasized. We further discuss the signals, sources, and limits of structural plasticity of the lung in alveolar hypoxia and following a loss of lung units, and the promise and caveats of interventions aimed at augmenting endogenous adaptive responses. Our objective is to understand how individual components are matched at multiple levels to optimize organ function in the face of physiological demands or pathological constraints. Copyright © 2016 John Wiley & Sons, Inc.

  20. Lung Structure and the Intrinsic Challenges of Gas Exchange

    Science.gov (United States)

    Hsia, Connie C.W.; Hyde, Dallas M.; Weibel, Ewald R.

    2016-01-01

    Structural and functional complexities of the mammalian lung evolved to meet a unique set of challenges, namely, the provision of efficient delivery of inspired air to all lung units within a confined thoracic space, to build a large gas exchange surface associated with minimal barrier thickness and a microvascular network to accommodate the entire right ventricular cardiac output while withstanding cyclic mechanical stresses that increase several folds from rest to exercise. Intricate regulatory mechanisms at every level ensure that the dynamic capacities of ventilation, perfusion, diffusion, and chemical binding to hemoglobin are commensurate with usual metabolic demands and periodic extreme needs for activity and survival. This article reviews the structural design of mammalian and human lung, its functional challenges, limitations, and potential for adaptation. We discuss (i) the evolutionary origin of alveolar lungs and its advantages and compromises, (ii) structural determinants of alveolar gas exchange, including architecture of conducting bronchovascular trees that converge in gas exchange units, (iii) the challenges of matching ventilation, perfusion, and diffusion and tissue-erythrocyte and thoracopulmonary interactions. The notion of erythrocytes as an integral component of the gas exchanger is emphasized. We further discuss the signals, sources, and limits of structural plasticity of the lung in alveolar hypoxia and following a loss of lung units, and the promise and caveats of interventions aimed at augmenting endogenous adaptive responses. Our objective is to understand how individual components are matched at multiple levels to optimize organ function in the face of physiological demands or pathological constraints. PMID:27065169

  1. Effects of chronic acetazolamide administration on gas exchange and acid-base control in pulmonary circulation in exercising horses.

    Science.gov (United States)

    Vengust, M; Stämpfli, H; De Moraes, A N; Teixeiro-Neto, F; Viel, L; Heigenhauser, G

    2010-11-01

    Carbonic anhydrase (CA) catalyses the hydration/dehydration reaction of CO(2) and increases the rate of Cl(-) and HCO(3)(-) exchange between the erythrocytes and plasma. Therefore, chronic inhibition of CA has a potential to attenuate CO(2) output and induce greater metabolic and respiratory acidosis in exercising horses. To determine the effects of Carbonic anhydrase inhibition on CO(2) output and ionic exchange between erythrocytes and plasma and their influence on acid-base balance in the pulmonary circulation (across the lung) in exercising horses with and without CA inhibition. Six horses were exercised to exhaustion on a treadmill without (Con) and with CA inhibition (AczTr). CA inhibition was achieved with administration of acetazolamide (10 mg/kg bwt t.i.d. for 3 days and 30 mg/kg bwt before exercise). Arterial, mixed venous blood and CO(2) output were sampled at rest and during exercise. An integrated physicochemical systems approach was used to describe acid base changes. AczTr decreased the duration of exercise by 45% (P changes across the lung with exception of lactate. CO(2) and chloride changes in erythrocytes across the lung seem to be the major contributors to acid-base and ions balance in pulmonary circulation in exercising horses. © 2010 EVJ Ltd.

  2. Gas Transfer in Cellularized Collagen-Membrane Gas Exchange Devices.

    Science.gov (United States)

    Lo, Justin H; Bassett, Erik K; Penson, Elliot J N; Hoganson, David M; Vacanti, Joseph P

    2015-08-01

    Chronic lower respiratory disease is highly prevalent in the United States, and there remains a need for alternatives to lung transplant for patients who progress to end-stage lung disease. Portable or implantable gas oxygenators based on microfluidic technologies can address this need, provided they operate both efficiently and biocompatibly. Incorporating biomimetic materials into such devices can help replicate native gas exchange function and additionally support cellular components. In this work, we have developed microfluidic devices that enable blood gas exchange across ultra-thin collagen membranes (as thin as 2 μm). Endothelial, stromal, and parenchymal cells readily adhere to these membranes, and long-term culture with cellular components results in remodeling, reflected by reduced membrane thickness. Functionally, acellular collagen-membrane lung devices can mediate effective gas exchange up to ∼288 mL/min/m(2) of oxygen and ∼685 mL/min/m(2) of carbon dioxide, approaching the gas exchange efficiency noted in the native lung. Testing several configurations of lung devices to explore various physical parameters of the device design, we concluded that thinner membranes and longer gas exchange distances result in improved hemoglobin saturation and increases in pO2. However, in the design space tested, these effects are relatively small compared to the improvement in overall oxygen and carbon dioxide transfer by increasing the blood flow rate. Finally, devices cultured with endothelial and parenchymal cells achieved similar gas exchange rates compared with acellular devices. Biomimetic blood oxygenator design opens the possibility of creating portable or implantable microfluidic devices that achieve efficient gas transfer while also maintaining physiologic conditions.

  3. Emergency exercises and information exchange. Does practice make perfect? Final report

    Energy Technology Data Exchange (ETDEWEB)

    Naadland Holo, E

    1999-09-01

    This project has covered a series of exercises and exercise like activities, in addition to a survey of scenario development tools and development of a suggestion for a Nordic system for data and information exchange. The results from the activities are presented in this report in a methodical perspective. The results reveal three similar components in almost all exercise activities: tools and methods to be used in an emergency situation need further development, systems for communication and information exchange should be developed and implemented, and the format and content of the information to be exchanged in an emergency situation should be agreed upon. Recommendations for future tasks regarding Nordic exercises are given according to this methodical approach. A major aspect here is to develop strategies for the over-all emergency planning. Such strategies should include the use of systematically chosen exercise types to improve the emergency response in a systematic way. (au)

  4. Gas exchange measurements in natural systems

    International Nuclear Information System (INIS)

    Broecker, W.S.; Peng, T.H.

    1983-01-01

    Direct knowledge of the rates of gas exchange in lakes and the ocean is based almost entirely on measurements of the isotopes 14 C, 222 Rn and 3 He. The distribution of natural radiocarbon has yielded the average rate of CO 2 exchange for the ocean and for several closed basin lakes. That of bomb produced radiocarbon has been used in the same systems. The 222 Rn to 226 Ra ratio in open ocean surface water has been used to give local short term gas exchange rates. The radon method generally cannot be used in lakes, rivers, estuaries or shelf areas because of the input of radon from sediments. A few attempts have been made to use the excess 3 He produced by decay of bomb produced tritium in lakes to give gas transfer rates. The uncertainty in the molecular diffusivity of helium and in the diffusivity dependence of the rate of gas transfer holds back the application of this method. A few attempts have been made to enrich the surface waters of small lakes with 226 Ra and 3 H in order to allow the use of the 222 Rn and 3 He methods. While these studies give broadly concordant results, many questions remain unanswered. The wind velocity dependence of gas exchange rate has yet to be established in field studies. The dependence of gas exchange rate on molecular diffusivity also remains in limbo. Finally, the degree of enhancement of CO 2 exchange through chemical reactions has been only partially explored. 49 references, 2 figures, 2 tables

  5. Impact of airway gas exchange on the multiple inert gas elimination technique: theory.

    Science.gov (United States)

    Anderson, Joseph C; Hlastala, Michael P

    2010-03-01

    The multiple inert gas elimination technique (MIGET) provides a method for estimating alveolar gas exchange efficiency. Six soluble inert gases are infused into a peripheral vein. Measurements of these gases in breath, arterial blood, and venous blood are interpreted using a mathematical model of alveolar gas exchange (MIGET model) that neglects airway gas exchange. A mathematical model describing airway and alveolar gas exchange predicts that two of these gases, ether and acetone, exchange primarily within the airways. To determine the effect of airway gas exchange on the MIGET, we selected two additional gases, toluene and m-dichlorobenzene, that have the same blood solubility as ether and acetone and minimize airway gas exchange via their low water solubility. The airway-alveolar gas exchange model simulated the exchange of toluene, m-dichlorobenzene, and the six MIGET gases under multiple conditions of alveolar ventilation-to-perfusion, VA/Q, heterogeneity. We increased the importance of airway gas exchange by changing bronchial blood flow, Qbr. From these simulations, we calculated the excretion and retention of the eight inert gases and divided the results into two groups: (1) the standard MIGET gases which included acetone and ether and (2) the modified MIGET gases which included toluene and m-dichlorobenzene. The MIGET mathematical model predicted distributions of ventilation and perfusion for each grouping of gases and multiple perturbations of VA/Q and Qbr. Using the modified MIGET gases, MIGET predicted a smaller dead space fraction, greater mean VA, greater log(SDVA), and more closely matched the imposed VA distribution than that using the standard MIGET gases. Perfusion distributions were relatively unaffected.

  6. Usefulness of decrease in oxygen uptake efficiency to identify gas exchange abnormality in patients with idiopathic pulmonary arterial hypertension.

    Directory of Open Access Journals (Sweden)

    Xiaoyue Tan

    Full Text Available BACKGROUND: Decline in oxygen uptake efficiency (OUE, especially during exercise, is found in patients with chronic heart failure. In this study we aimed to test the validity and usefulness of OUE in evaluating gas exchange abnormality of patients with idiopathic pulmonary arterial hypertension (IPAH. METHODS: We retrospectively investigated the cardiopulmonary exercise test (CPET with gas exchange measurements in 32 patients with confirmed IPAH. All patients also had resting hemodynamic measurements and pulmonary function test (PFT. Sixteen healthy subjects, matched by age, sex, and body size were used as controls, also had CPET and PFT measurements. RESULTS: In IPAH patients, the magnitude of absolute and percentage of predicted (%pred oxygen uptake efficiency slope (OUES and oxygen uptake efficiency plateau (OUEP, as well as several other CPET parameters, were strikingly worse than healthy subjects (P<0.0001. Pattern of changes in OUE in patients is similar to that in controls, In IPAH patients, OUE values at rest, warming up, anaerobic threshold and peak exercise were all significantly lower than in normal (P<0.0001. OUEP%pred, better than OUES%pred, correlated significantly with New York Heart Association (NYHA functional Class (r = -0.724, P<0.005, Total Pulmonary Vascular Resistance (TPVR (r = -0.694, P<0.005, diffusing capacity for carbon monoxide (DLCO (r = 0.577, P<0.05, and the lowest ventilation versus CO2 output ratio during exercise (LowestV˙E/V˙CO2 (r = -0.902, P<0.0001. In addition, the coefficient of variation (COV of OUEP was lower (20.9% markedly than OUES (34.3% (P<0.0001. CONCLUSIONS: In patients with IPAH, OUES and OUEP are both significantly lower than the healthy subjects. OUEP is a better physiological parameter than OUES in evaluating the gas exchange abnormality of patients with IPAH.

  7. Gas exchange in avian embryos and hatchlings.

    Science.gov (United States)

    Mortola, Jacopo P

    2009-08-01

    The avian egg has been proven to be an excellent model for the study of the physical principles and the physiological characteristics of embryonic gas exchange. In recent years, it has become a model for the studies of the prenatal development of pulmonary ventilation, its chemical control and its interaction with extra-pulmonary gas exchange. Differently from mammals, in birds the initiation of pulmonary ventilation and the transition from diffusive to convective gas exchange are gradual and slow-occurring events amenable to detailed investigations. The absence of the placenta and of the mother permits the study of the mechanisms of embryonic adaptation to prenatal perturbations in a way that would be impossible with mammalian preparations. First, this review summarises the general aspects of the natural history of the avian egg that are pertinent to embryonic metabolism, growth and gas exchange and the characteristics of the structures participating in gas exchange. Then, the review focuses on the embryonic development of pulmonary ventilation, its regulation in relation to the embryo's environment and metabolic state, the effects that acute or sustained changes in embryonic temperature or oxygenation can have on growth, metabolism and ventilatory control.

  8. Pulmonary gas exchange at maximal exercise in Danish lowlanders during 8 wk of acclimatization to 4,100 m and in high-altitude Aymara natives

    DEFF Research Database (Denmark)

    Lundby, Carsten; Calbet, Jose A L; van Hall, Gerrit

    2004-01-01

    We aimed to test effects of altitude acclimatization on pulmonary gas exchange at maximal exercise. Six lowlanders were studied at sea level, in acute hypoxia (AH), and after 2 and 8 wk of acclimatization to 4,100 m (2W and 8W) and compared with Aymara high-altitude natives residing...... in AH but increased significantly with acclimatization (51 +/- 1.1, 58 +/- 1.7, and 62 +/- 1.6 mmHg in AH, 2W, and 8W, respectively). PaO2 in lowlanders reached levels that were not different from those in high-altitude natives (66 +/- 1.2 mmHg). Arterial O2 saturation (SaO2) decreased during maximum......, but even acclimatization for 8 wk is insufficient to achieve levels reached by high-altitude natives....

  9. On factors influencing air-water gas exchange in emergent wetlands

    Science.gov (United States)

    Ho, David T.; Engel, Victor C.; Ferron, Sara; Hickman, Benjamin; Choi, Jay; Harvey, Judson W.

    2018-01-01

    Knowledge of gas exchange in wetlands is important in order to determine fluxes of climatically and biogeochemically important trace gases and to conduct mass balances for metabolism studies. Very few studies have been conducted to quantify gas transfer velocities in wetlands, and many wind speed/gas exchange parameterizations used in oceanographic or limnological settings are inappropriate under conditions found in wetlands. Here six measurements of gas transfer velocities are made with SF6 tracer release experiments in three different years in the Everglades, a subtropical peatland with surface water flowing through emergent vegetation. The experiments were conducted under different flow conditions and with different amounts of emergent vegetation to determine the influence of wind, rain, water flow, waterside thermal convection, and vegetation on air-water gas exchange in wetlands. Measured gas transfer velocities under the different conditions ranged from 1.1 cm h−1 during baseline conditions to 3.2 cm h−1 when rain and water flow rates were high. Commonly used wind speed/gas exchange relationships would overestimate the gas transfer velocity by a factor of 1.2 to 6.8. Gas exchange due to thermal convection was relatively constant and accounted for 14 to 51% of the total measured gas exchange. Differences in rain and water flow among the different years were responsible for the variability in gas exchange, with flow accounting for 37 to 77% of the gas exchange, and rain responsible for up to 40%.

  10. Metabolism and gas exchange patterns in Rhodnius prolixus.

    Science.gov (United States)

    Schilman, Pablo E

    Insect's metabolic rate and patterns of gas-exchange varies according to different factors such as: species, activity, mass, and temperature among others. One particular striking pattern of gas-exchange in insects is discontinuous gas-exchange cycles, for which many different hypotheses regarding their evolution have been stated. This article does not pretend to be an extensive review on the subject, rather to focus on the work performed on the haematophagous bug Rhodnius prolixus, a model organism used from the mid XX century until present days, with the great influence of Wigglesworth and his students/collaborator's work. I have no doubt that the renovated field of insect gas-exchange has a bright future and will advance at large gaits thank to the help of this model organism, R. prolixus, whose entire genome has recently being unraveled. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Use of argon to measure gas exchange in turbulent mountain streams

    Science.gov (United States)

    Hall, Robert O., Jr.; Madinger, Hilary L.

    2018-05-01

    Gas exchange is a parameter needed in stream metabolism and trace gas emissions models. One way to estimate gas exchange is via measuring the decline of added tracer gases such as sulfur hexafluoride (SF6). Estimates of oxygen (O2) gas exchange derived from SF6 additions require scaling via Schmidt number (Sc) ratio, but this scaling is uncertain under conditions of high gas exchange via bubbles because scaling depends on gas solubility as well as Sc. Because argon (Ar) and O2 have nearly identical Schmidt numbers and solubility, Ar may be a useful tracer gas for estimating stream O2 exchange. Here we compared rates of gas exchange measured via Ar and SF6 for turbulent mountain streams in Wyoming, USA. We measured Ar as the ratio of Ar : N2 using a membrane inlet mass spectrometer (MIMS). Normalizing to N2 confers higher precision than simply measuring [Ar] alone. We consistently enriched streams with Ar from 1 to 18 % of ambient Ar concentration and could estimate gas exchange rate using an exponential decline model. The mean ratio of gas exchange of Ar relative to SF6 was 1.8 (credible interval 1.1 to 2.5) compared to the theoretical estimate 1.35, showing that using SF6 would have underestimated exchange of Ar. Steep streams (slopes 11-12 %) had high rates of gas exchange velocity normalized to Sc = 600 (k600, 57-210 m d-1), and slope strongly predicted variation in k600 among all streams. We suggest that Ar is a useful tracer because it is easily measured, requires no scaling assumptions to estimate rates of O2 exchange, and is not an intense greenhouse gas as is SF6. We caution that scaling from rates of either Ar or SF6 gas exchange to CO2 is uncertain due to solubility effects in conditions of bubble-mediated gas transfer.

  12. A Controlled Environment System For Measuring Plant-Atmosphere Gas Exchange

    Science.gov (United States)

    James M. Brown

    1975-01-01

    Describes an inexpensive, efficient system for measuring plant-atmosphere gas exchange. Designed to measure transpiration from potted tree seedlings, it is readily adaptable for measuring other gas exchanges or gas exchange by plant parts. Light level, air and root temperature can be precisely controlled at minimum cost.

  13. Gas exchanges in annonaceae species under different crop protections

    Directory of Open Access Journals (Sweden)

    Daniel Baron

    2014-01-01

    Full Text Available This study aims to investigate the gas exchanges of different species of Annonaceae due to environmental variations provided by different types of crop protection. 'Araticum-de-terra-fria', 'araticum-mirim', 'biribá' and atemoya seedlings were cultived in three different crop protections: nursery, greenhouse and warm house. Gas exchanges were obtained in six plants, from 9:00 am to 11:00 am, with IRGA, LI-6400, at 180 Days After Transplanting. The different types of crop protection had a direct influence on gas exchanges of these species. Thus, nursery provided suitable conditions for 'araticum-de-terra-fria', 'araticum-mirim' and 'biribá', increasing their gas exchanges. To atemoya the best crop protection was the greenhouse.

  14. Reversible brain inactivation induces discontinuous gas exchange in cockroaches.

    Science.gov (United States)

    Matthews, Philip G D; White, Craig R

    2013-06-01

    Many insects at rest breathe discontinuously, alternating between brief bouts of gas exchange and extended periods of breath-holding. The association between discontinuous gas exchange cycles (DGCs) and inactivity has long been recognised, leading to speculation that DGCs lie at one end of a continuum of gas exchange patterns, from continuous to discontinuous, linked to metabolic rate (MR). However, the neural hypothesis posits that it is the downregulation of brain activity and a change in the neural control of gas exchange, rather than low MR per se, which is responsible for the emergence of DGCs during inactivity. To test this, Nauphoeta cinerea cockroaches had their brains inactivated by applying a Peltier-chilled cold probe to the head. Once brain temperature fell to 8°C, cockroaches switched from a continuous to a discontinuous breathing pattern. Re-warming the brain abolished the DGC and re-established a continuous breathing pattern. Chilling the brain did not significantly reduce the cockroaches' MR and there was no association between the gas exchange pattern displayed by the insect and its MR. This demonstrates that DGCs can arise due to a decrease in brain activity and a change in the underlying regulation of gas exchange, and are not necessarily a simple consequence of low respiratory demand.

  15. LACK OF AGREEMENT BETWEEN GAS EXCHANGE VARIABLES MEASURED BY TWO METABOLIC SYSTEMS

    Directory of Open Access Journals (Sweden)

    DjordjeG. Jakovljevic

    2008-03-01

    Full Text Available The purpose of this study was to assess the agreement and consistency between gas exchange variables measured by two online metabolic systems during an incremental exercise test. After obtaining local ethics approval and informed consent, 15 healthy subjects performed an incremental exercise test to volitional fatigue using the Bruce protocol. The Innocor (Innovision, Denmark and CardiO2 (Medical Graphics, USA systems were placed in series, with the Innocor mouthpiece attached to the pneumotach of the CardiO2. Metabolic data were analysed during the last 30 seconds of each stage and at peak exercise. There were non- significant differences (p > 0.05 between the two systems in estimation of oxygen consumption (VO2 and in minute ventilation (VE. Mean Cronbach's alpha for VO2 and VE were 0.88 and 0.92. The Bland-Altman analysis revealed that limits of agreement were -0.52 to 0.55 l.min-1 for VO2, and -8.74 to 10.66 l.min-1 for VE. Carbon dioxide production (VCO2 and consequently respiratory exchange ratio (RER measured by the Innocor were significantly lower (p < 0.05 through all stages. The CardiO2 measured fraction of expired carbon dioxide (FeCO2 significantly higher (p < 0.05. The limits of agreement for VO2 and VE are wide and unacceptable in cardio-pulmonary exercise testing. The Innocor reported VCO2 systematically lower. Therefore the Innocor and CardiO2 metabolic systems cannot be used interchangeably without affecting the diagnosis of an individual patient. Results from the present study support previous suggestion that considerable care is needed when comparing metabolic data obtained from different automated metabolic systems.

  16. Fundamental structural aspects and features in the bioengineering of the gas exchangers: comparative perspectives.

    Science.gov (United States)

    Maina, J N

    2002-01-01

    the ubiquitous method of transfer of O2 across biological tissues. Gills, evaginated gas exchangers, were the primordial respiratory organs that evolved for water breathing, whereas lungs (invaginated gas exchangers) developed for terrestrial (air) breathing. Transitional (= bimodal = amphibious) breathing has evolved in animals with specialized organs that extract O2 from both water and air. Lungs are tidally (= bidirectionally) ventilated, while gills are unidirectionally ventilated, a feature that allows the highly efficient counter-current disposition between blood and water. Since animals occupy inconstant environmental milieus and their metabolic states vary, gas exchangers are designed to operate optimally across a spectrum of conditions that range from resting to exercise and even under hypoxia. Inbuilt structural and functional flexibility provides the requisite safety factors that allow adjustments to modest pressures. The fundamental structural features that determine the respiratory function of a gas exchanger are respiratory surface area, thickness of the blood-water/gas (tissue) barrier and volume of the pulmonary capillary blood. The diffusing capacity of a gas exchanger correlates directly with the surface area and inversely with the thickness of the blood-water/gas (tissue) barrier. An extensive surface area is generated in gills by extensive stratification of the gas exchanger and in lungs by profuse internal subdivision. Compartmentalization yields small terminal gas exchange compartments that compel greater commitment of energy to ventilate. The surfactant, a phospholipid lining, reduces the forces of surface tension at the air-water interface. This attenuates the propensity of physical collapse of the minute gas exchange units and minimizes the cost of ventilation. The surfactant characterizes all the gas exchangers derived from the piscine air bladder. In the lower air-breathing vertebrates, such as the lungfishes (Dipnoi), amphibians and certain

  17. Quantitative aspects of oxygen and carbon dioxide exchange ...

    African Journals Online (AJOL)

    Quantitative aspects of oxygen and carbon dioxide exchange through the ... ceratophthalmus (Crustacea: Decapoda) during rest and exercise in water and ... intersects zero time on the x-axis, indicating rapid gas exchange at the lung surface.

  18. Seasonal variations in body composition, maximal oxygen uptake, and gas exchange threshold in cross-country skiers.

    Science.gov (United States)

    Polat, Metin; Korkmaz Eryılmaz, Selcen; Aydoğan, Sami

    2018-01-01

    In order to ensure that athletes achieve their highest performance levels during competitive seasons, monitoring their long-term performance data is crucial for understanding the impact of ongoing training programs and evaluating training strategies. The present study was thus designed to investigate the variations in body composition, maximal oxygen uptake (VO 2max ), and gas exchange threshold values of cross-country skiers across training phases throughout a season. In total, 15 athletes who participate in international cross-country ski competitions voluntarily took part in this study. The athletes underwent incremental treadmill running tests at 3 different time points over a period of 1 year. The first measurements were obtained in July, during the first preparation period; the second measurements were obtained in October, during the second preparation period; and the third measurements were obtained in February, during the competition period. Body weight, body mass index (BMI), body fat (%), as well as VO 2max values and gas exchange threshold, measured using V-slope method during the incremental running tests, were assessed at all 3 time points. The collected data were analyzed using SPSS 20 package software. Significant differences between the measurements were assessed using Friedman's twoway variance analysis with a post hoc option. The athletes' body weights and BMI measurements at the third point were significantly lower compared with the results of the second measurement ( p exchange threshold, running speed at the gas exchange threshold, VO 2max , amount of oxygen consumed at gas exchange threshold level (VO 2GET ), maximal heart rate (HR max ), and heart rate at gas exchange threshold level (HR GET ) values did not significantly differ between the measurement time points ( p >0.05). VO 2max and gas exchange threshold values recorded during the third measurements, the timing of which coincided with the competitive season of the cross-country skiers

  19. Efficient gas exchange between a boreal river and the atmosphere

    Science.gov (United States)

    Huotari, Jussi; Haapanala, Sami; Pumpanen, Jukka; Vesala, Timo; Ojala, Anne

    2013-11-01

    largest uncertainties in accurately resolving the role of rivers and streams in carbon cycling stem from difficulties in determining gas exchange between water and the atmosphere. So far, estimates for river-atmosphere gas exchange have lacked direct ecosystem-scale flux measurements not disturbing gas exchange across the air-water interface. We conducted the first direct riverine gas exchange measurements with eddy covariance in tandem with continuous surface water CO2 measurements in a large boreal river for 30 days. Our measured gas transfer velocity was, on average, 20.8 cm h-1, which is clearly higher than the model estimates based on river channel morphology and water velocity, whereas our floating chambers gave comparable values at 17.3 cm h-1. These results demonstrate that present estimates for riverine CO2 emissions are very likely too low. This result is also relevant to any other gases emitted, as their diffusive exchange rates are similarly proportional to gas transfer velocity.

  20. A Laboratory Exercise Using a Physical Model for Demonstrating Countercurrent Heat Exchange

    Science.gov (United States)

    Loudon, Catherine; Davis-Berg, Elizabeth C.; Botz, Jason T.

    2012-01-01

    A physical model was used in a laboratory exercise to teach students about countercurrent exchange mechanisms. Countercurrent exchange is the transport of heat or chemicals between fluids moving in opposite directions separated by a permeable barrier (such as blood within adjacent blood vessels flowing in opposite directions). Greater exchange of…

  1. Spume Drops: Their Potential Role in Air-Sea Gas Exchange

    Science.gov (United States)

    Monahan, Edward C.; Staniec, Allison; Vlahos, Penny

    2017-12-01

    After summarizing the time scales defining the change of the physical properties of spume and other droplets cast up from the sea surface, the time scales governing drop-atmosphere gas exchange are compared. Following a broad review of the spume drop production functions described in the literature, a subset of these functions is selected via objective criteria, to represent typical, upper bound, and lower bound production functions. Three complementary mechanisms driving spume-atmosphere gas exchange are described, and one is then used to estimate the relative importance, over a broad range of wind speeds, of this spume drop mechanism compared to the conventional, diffusional, sea surface mechanism in air-sea gas exchange. While remaining uncertainties in the wind dependence of the spume drop production flux, and in the immediate sea surface gas flux, preclude a definitive conclusion, the findings of this study strongly suggest that, at high wind speeds (>20 m s-1 for dimethyl sulfide and >30 m s-1 for gases such a carbon dioxide), spume drops do make a significant contribution to air-sea gas exchange.Plain Language SummaryThis paper evaluates the existing spume drop generation functions available to date and selects a reasonable upper, lower and mid range function that are reasonable for use in air sea exchange models. Based on these the contribution of spume drops to overall air sea gas exchange at different wind speeds is then evaluated to determine the % contribution of spume. Generally below 20ms-1 spume drops contribute <1% of gas exchange but may account for a significant amount of gas exchange at higher wind speeds.

  2. Dynamic Characteristics of Ventilatory and Gas Exchange during Sinusoidal Walking in Humans.

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Fukuoka

    Full Text Available Our present study investigated whether the ventilatory and gas exchange responses show different dynamics in response to sinusoidal change in cycle work rate or walking speed even if the metabolic demand was equivalent in both types of exercise. Locomotive parameters (stride length and step frequency, breath-by-breath ventilation (V̇E and gas exchange (CO2 output (V̇CO2 and O2 uptake (V̇O2 responses were measured in 10 healthy young participants. The speed of the treadmill was sinusoidally changed between 3 km·h-1 and 6 km·h-1 with various periods (from 10 to 1 min. The amplitude of locomotive parameters against sinusoidal variation showed a constant gain with a small phase shift, being independent of the oscillation periods. In marked contrast, when the periods of the speed oscillations were shortened, the amplitude of V̇E decreased sharply whereas the phase shift of V̇E increased. In comparing walking and cycling at the equivalent metabolic demand, the amplitude of V̇E during sinusoidal walking (SW was significantly greater than that during sinusoidal cycling (SC, and the phase shift became smaller. The steeper slope of linear regression for the V̇E amplitude ratio to V̇CO2 amplitude ratio was observed during SW than SC. These findings suggested that the greater amplitude and smaller phase shift of ventilatory dynamics were not equivalent between SW and SC even if the metabolic demand was equivalent between both exercises. Such phenomenon would be derived from central command in proportion to locomotor muscle recruitment (feedforward and muscle afferent feedback.

  3. Heat exchangers for automotive gas turbine power plants

    International Nuclear Information System (INIS)

    Penny, R.N.

    1974-01-01

    Automotive gas turbine power plants are now in the final stages of development for quantity manufacture. A crucial factor in this development is the regenerative heat exchanger. The relative merits of the rotary regenerative and static recuperative heat exchanger are compared. Thermal efficiency and initial cost are two vital issues involved in the design of small gas turbines for the commercial establishment of gas turbine vehicles. The selection of a material for the rotaty regenerator is essentially related to resolving the two vital issues of future small gas turbines and is, therefore, analysed. The account of the pioneering work involved in engineering the glass ceramic and other non-metal regenerators includes a complete failure analysis based on running experience with over 200 ceramic regenerators. The problems of sealing, supporting and manufacturing the ceramic regenerator are discussed and future practical designs are outlined. Heat exchange theory applied to small gas turbines is also reviewed

  4. Gas exchange between the forest and the atmosphere

    International Nuclear Information System (INIS)

    Murphy, C.E. Jr.

    1985-01-01

    Forest gas exchange is discussed in terms of the processes that control the rate of exchange with the atmosphere. Examples are presented to show how vegetative uptake control is varied for gases with different characteristics. The prediction of uptake for large areas and over long periods of time is discussed in terms of quantitative models of the gas exchange processes. Finally, remote sensing is suggested as a means of obtaining the parameters needed to make the model predictions. 46 refs., 6 figs

  5. Maximising the clinical use of exercise gaseous exchange testing in children with repaired cyanotic congenital heart defects: the development of an appropriate test strategy.

    Science.gov (United States)

    McManus, A; Leung, M

    2000-04-01

    Implicit in deciding upon an exercise test strategy to elucidate cardiopulmonary function in children with congenital heart disease are appropriate application of gas exchange techniques and the significance of the data collected to the specific congenital heart disorder. Post-operative cardiopulmonary responses to exercise in cyanotic disorders are complex and, despite a large body of extant literature in paediatric patients, there has been much difficulty in achieving quality and consistency of data. Maximal oxygen uptake is widely recognised as the best single indicator of cardiopulmonary function and has therefore been the focus of most clinical exercise tests in children. Many children with various heart anomalies are able to exercise to maximum without adverse symptoms, and it is essential that test termination is based on the same criteria for these children. Choosing appropriate, valid indicators of maximum in children with congenital heart disease is beset by difficulties. Such maximal intensity exercise testing procedures have been challenged on the grounds that they do not give a good indication of cardiopulmonary function that is relevant to real life situations. Furthermore, they are prone to much interindividual variability and error in the definition of maximal exertion. Alternative strategies have been proposed which focus upon dynamic submaximal and kinetic cardiopulmonary responses, which are thought to be less dependent on maximal voluntary effort and more suited to the daily activity patterns of children. These methods are also not without problems. Variability in anaerobic threshold measurements and controversy regarding its physiological meaning have been debated. It is recommended that an appropriate cardiopulmonary exercise gas exchange test strategy, which provides clinically useful information for children with cyanotic congenital heart disease, should include both maximal and submaximal data. The inclusion of oxygen uptake kinetics and

  6. Setting an Upper Limit on Gas Exchange Through Sea-Spray

    Science.gov (United States)

    Vlahos, P.; Monahan, E. C.; Andreas, E. L.

    2016-02-01

    Air-sea gas exchange parameterization is critical to understanding both climate forcing and feedbacks and is key in biogeochemistry cycles. Models based on wind speed have provided empirical estimates of gas exchange that are useful though it is likely that at high wind speeds of over 10 m/s there are important gas exchange parameters including bubbles and sea spray that have not been well constrained. Here we address the sea-spray component of gas exchange at these high wind speeds to set sn upper boundary condition for the gas exchange of the six model gases including; nobel gases helium, neon and argon, diatomic gases nitrogen and oxygen and finally, the more complex gas carbon dioxide. Estimates are based on the spray generation function of Andreas and Monahan and the gases are tested under three scenarios including 100 percent saturation and complete droplet evaporation, 100 percent saturation and a more realistic scenario in which a fraction of droplets evaporate completely, a fraction evaporate to some degree and a fraction returns to the water side without significant evaporation. Finally the latter scenario is applied to representative under saturated concentrations of the gases.

  7. Universal model for water costs of gas exchange by animals and plants.

    Science.gov (United States)

    Woods, H Arthur; Smith, Jennifer N

    2010-05-04

    For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for specific taxa, we integrate properties common to all terrestrial gas exchangers into a universal model of water loss. The model predicts that water loss scales to gas exchange with an exponent of 1 and that the amount of water lost per unit of gas exchanged depends on several factors: the surface temperature of the respiratory system near the outside of the organism, the gas consumed (oxygen or carbon dioxide), the steepness of the gradients for gas and vapor, and the transport mode (convective or diffusive). Model predictions were largely confirmed by data on 202 species in five taxa--insects, birds, bird eggs, mammals, and plants--spanning nine orders of magnitude in rate of gas exchange. Discrepancies between model predictions and data seemed to arise from biologically interesting violations of model assumptions, which emphasizes how poorly we understand gas exchange in some taxa. The universal model provides a unified conceptual framework for analyzing exchange-associated water losses across taxa with radically different metabolic and exchange systems.

  8. A new method for noninvasive measurement of pulmonary gas exchange using expired gas.

    Science.gov (United States)

    West, John B; Prisk, G Kim

    2018-01-01

    Measurement of the gas exchange efficiency of the lung is often required in the practice of pulmonary medicine and in other settings. The traditional standard is the values of the PO2, PCO2, and pH of arterial blood. However arterial puncture requires technical expertise, is invasive, uncomfortable for the patient, and expensive. Here we describe how the composition of expired gas can be used in conjunction with pulse oximetry to obtain useful measures of gas exchange efficiency. The new procedure is noninvasive, well tolerated by the patient, and takes only a few minutes. It could be particularly useful when repeated measurements of pulmonary gas exchange are required. One product of the procedure is the difference between the PO2 of end-tidal alveolar gas and the calculated PO2 of arterial blood. This measurement is related to the classical alveolar-arterial PO2 difference based on ideal alveolar gas. However that traditional index is heavily influenced by lung units with low ventilation-perfusion ratios, whereas the new index has a broader physiological basis because it includes contributions from the whole lung. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Exchange energy in the local Airy gas approximation

    DEFF Research Database (Denmark)

    Vitos, Levente; Johansson, B.; Kollár, J.

    2000-01-01

    The Airy gas model of the edge electron gas is used to construct an exchange-energy functional that is an alternative to those obtained in the local-density and generalized-gradient approximations. Test calculations for rare-gas atoms, molecules, solids, and surfaces show that the Airy gas...

  10. Continuous measurement of air-water gas exchange by underwater eddy covariance

    Science.gov (United States)

    Berg, Peter; Pace, Michael L.

    2017-12-01

    Exchange of gases, such as O2, CO2, and CH4, over the air-water interface is an important component in aquatic ecosystem studies, but exchange rates are typically measured or estimated with substantial uncertainties. This diminishes the precision of common ecosystem assessments associated with gas exchanges such as primary production, respiration, and greenhouse gas emission. Here, we used the aquatic eddy covariance technique - originally developed for benthic O2 flux measurements - right below the air-water interface (˜ 4 cm) to determine gas exchange rates and coefficients. Using an acoustic Doppler velocimeter and a fast-responding dual O2-temperature sensor mounted on a floating platform the 3-D water velocity, O2 concentration, and temperature were measured at high-speed (64 Hz). By combining these data, concurrent vertical fluxes of O2 and heat across the air-water interface were derived, and gas exchange coefficients were calculated from the former. Proof-of-concept deployments at different river sites gave standard gas exchange coefficients (k600) in the range of published values. A 40 h long deployment revealed a distinct diurnal pattern in air-water exchange of O2 that was controlled largely by physical processes (e.g., diurnal variations in air temperature and associated air-water heat fluxes) and not by biological activity (primary production and respiration). This physical control of gas exchange can be prevalent in lotic systems and adds uncertainty to assessments of biological activity that are based on measured water column O2 concentration changes. For example, in the 40 h deployment, there was near-constant river flow and insignificant winds - two main drivers of lotic gas exchange - but we found gas exchange coefficients that varied by several fold. This was presumably caused by the formation and erosion of vertical temperature-density gradients in the surface water driven by the heat flux into or out of the river that affected the turbulent

  11. Continuous measurement of air–water gas exchange by underwater eddy covariance

    Directory of Open Access Journals (Sweden)

    P. Berg

    2017-12-01

    Full Text Available Exchange of gases, such as O2, CO2, and CH4, over the air–water interface is an important component in aquatic ecosystem studies, but exchange rates are typically measured or estimated with substantial uncertainties. This diminishes the precision of common ecosystem assessments associated with gas exchanges such as primary production, respiration, and greenhouse gas emission. Here, we used the aquatic eddy covariance technique – originally developed for benthic O2 flux measurements – right below the air–water interface (∼ 4 cm to determine gas exchange rates and coefficients. Using an acoustic Doppler velocimeter and a fast-responding dual O2–temperature sensor mounted on a floating platform the 3-D water velocity, O2 concentration, and temperature were measured at high-speed (64 Hz. By combining these data, concurrent vertical fluxes of O2 and heat across the air–water interface were derived, and gas exchange coefficients were calculated from the former. Proof-of-concept deployments at different river sites gave standard gas exchange coefficients (k600 in the range of published values. A 40 h long deployment revealed a distinct diurnal pattern in air–water exchange of O2 that was controlled largely by physical processes (e.g., diurnal variations in air temperature and associated air–water heat fluxes and not by biological activity (primary production and respiration. This physical control of gas exchange can be prevalent in lotic systems and adds uncertainty to assessments of biological activity that are based on measured water column O2 concentration changes. For example, in the 40 h deployment, there was near-constant river flow and insignificant winds – two main drivers of lotic gas exchange – but we found gas exchange coefficients that varied by several fold. This was presumably caused by the formation and erosion of vertical temperature–density gradients in the surface water driven by the heat flux into or

  12. Specialists' meeting on heat exchanging components of gas-cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1984-07-01

    The objective of the Meeting sponsored by IAEA was to provide a forum for the exchange and discussion of technical information related to heat exchanging and heat conducting components for gas-cooled reactors. The technical part of the meeting covered eight subjects: Heat exchanging components for process heat applications, design and requirements, and research and development programs; Status of the design and construction of intermediate He/He exchangers; Design, construction and performance of steam generators; Metallic materials and design codes; Design and construction of valves and hot gas ducts; Description of component test facilities and test results; Manufacturing of heat exchanging components.

  13. Specialists' meeting on heat exchanging components of gas-cooled reactors

    International Nuclear Information System (INIS)

    1984-01-01

    The objective of the Meeting sponsored by IAEA was to provide a forum for the exchange and discussion of technical information related to heat exchanging and heat conducting components for gas-cooled reactors. The technical part of the meeting covered eight subjects: Heat exchanging components for process heat applications, design and requirements, and research and development programs; Status of the design and construction of intermediate He/He exchangers; Design, construction and performance of steam generators; Metallic materials and design codes; Design and construction of valves and hot gas ducts; Description of component test facilities and test results; Manufacturing of heat exchanging components

  14. Influence of priming exercise on pulmonary O2 uptake kinetics during transitions to high-intensity exercise from an elevated baseline.

    Science.gov (United States)

    DiMenna, Fred J; Wilkerson, Daryl P; Burnley, Mark; Jones, Andrew M

    2008-08-01

    It has been suggested that the slower O2 uptake (VO2) kinetics observed when exercise is initiated from an elevated baseline metabolic rate are linked to an impairment of muscle O2 delivery. We hypothesized that "priming" exercise would significantly reduce the phase II time constant (tau) during subsequent severe-intensity cycle exercise initiated from an elevated baseline metabolic rate. Seven healthy men completed exercise transitions to 70% of the difference between gas exchange threshold (GET) and peak VO2 from a moderate-intensity baseline (90% GET) on three occasions in each of the "unprimed" and "primed" conditions. Pulmonary gas exchange, heart rate, and the electromyogram of m. vastus lateralis were measured during all tests. The phase II VO2 kinetics were slower when severe exercise was initiated from a baseline of moderate exercise compared with unloaded pedaling (mean+/-SD tau, 42+/-15 vs. 33+/-8 s; P0.05). The amplitude of the VO2 slow component and the change in electromyogram from minutes 2 to 6 were both significantly reduced following priming exercise (VO2 slow component: from 0.47+/-0.09 to 0.27+/-0.13 l/min; change in integrated electromyogram between 2 and 6 min: from 51+/-35 to 26+/-43% of baseline; Pchanges in muscle fiber activation.

  15. Universal model for water costs of gas exchange by animals and plants

    OpenAIRE

    Woods, H. Arthur; Smith, Jennifer N.

    2010-01-01

    For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for specific taxa, we integrate properties common to all terrestrial gas exchangers into a universal model of water loss. The model predicts that water loss scales to gas exchange with an exponent of 1 and that the amount of water lost per unit of gas exchanged depends on several factors: the surface t...

  16. The mechanisms underlying the production of discontinuous gas exchange cycles in insects.

    Science.gov (United States)

    Matthews, Philip G D

    2018-03-01

    This review examines the control of gas exchange in insects, specifically examining what mechanisms could explain the emergence of discontinuous gas exchange cycles (DGCs). DGCs are gas exchange patterns consisting of alternating breath-hold periods and bouts of gas exchange. While all insects are capable of displaying a continuous pattern of gas exchange, this episodic pattern is known to occur within only some groups of insects and then only sporadically or during certain phases of their life cycle. Investigations into DGCs have tended to emphasise the role of chemosensory thresholds in triggering spiracle opening as critical for producing these gas exchange patterns. However, a chemosensory basis for episodic breathing also requires an as-of-yet unidentified hysteresis between internal respiratory stimuli, chemoreceptors, and the spiracles. What has been less appreciated is the role that the insect's central nervous system (CNS) might play in generating episodic patterns of ventilation. The active ventilation displayed by many insects during DGCs suggests that this pattern could be the product of directed control by the CNS rather than arising passively as a result of self-sustaining oscillations in internal oxygen and carbon dioxide levels. This paper attempts to summarise what is currently known about insect gas exchange regulation, examining the location and control of ventilatory pattern generators in the CNS, the influence of chemoreceptor feedback in the form of O 2 and CO 2 /pH fluctuations in the haemolymph, and the role of state-dependent changes in CNS activity on ventilatory control. This information is placed in the context of what is currently known regarding the production of discontinuous gas exchange patterns.

  17. Gas exchange across the air - water interface determined with man-made and natural tracers

    International Nuclear Information System (INIS)

    Wanninkhof, R.H.

    1986-01-01

    Gas exchange coefficients were determined on Rockland Lake, NY; Crowley Lake, CA; and Mono Lake, CA which have surface areas of 1 km 2 , 20 km 2 , and 190 km 2 , respectively, by injecting a small amount of man made tracer gas, sulfur hexafluoride (SF 6 ) into the lake and measuring the rate of concentration decrease in the water column with time. The dependency of gas exchange on wind speed is similar for the three lakes indicating that wind fetch is not a critical parameter for the gas exchange coefficient for lakes with sizes greater than 1 km 2 . Little gas exchange occurs for wind speeds less than 2.5 m/s and gas exchange increases linearly with wind speed from 2.5 to 6 m/s. The relationship of gas exchange and wind speed for the lakes agrees well with a compilation of earlier single wind speed - exchange coefficient measurements on lakes and oceans but they are lower than most results obtained in wind tunnels

  18. Prototype Vent Gas Heat Exchanger for Exploration EVA - Performance and Manufacturing Characteristics

    Science.gov (United States)

    Quinn, Gregory J.; Strange, Jeremy; Jennings, Mallory

    2013-01-01

    NASA is developing new portable life support system (PLSS) technologies, which it is demonstrating in an unmanned ground based prototype unit called PLSS 2.0. One set of technologies within the PLSS provides suitable ventilation to an astronaut while on an EVA. A new component within the ventilation gas loop is a liquid-to-gas heat exchanger to transfer excess heat from the gas to the thermal control system s liquid coolant loop. A unique bench top prototype heat exchanger was built and tested for use in PLSS 2.0. The heat exchanger was designed as a counter-flow, compact plate fin type using stainless steel. Its design was based on previous compact heat exchangers manufactured by United Technologies Aerospace Systems (UTAS), but was half the size of any previous heat exchanger model and one third the size of previous liquid-to-gas heat exchangers. The prototype heat exchanger was less than 40 cubic inches and weighed 2.57 lb. Performance of the heat exchanger met the requirements and the model predictions. The water side and gas side pressure drops were less 0.8 psid and 0.5 inches of water, respectively, and an effectiveness of 94% was measured at the nominal air side pressure of 4.1 psia.

  19. Respiratory Mechanics and Gas Exchange: The Effect of Surfactants

    Science.gov (United States)

    Jbaily, Abdulrahman; Szeri, Andrew J.

    2017-11-01

    The purpose of the lung is to exchange gases, primarily oxygen and carbon dioxide, between the atmosphere and the circulatory system. To enable this exchange, the airways in the lungs terminate in some 300 million alveoli that provide adequate surface area for transport. During breathing, work must be done to stretch various tissues to accommodate a greater volume of gas. Considerable work must also be done to expand the liquid lining (hypophase) that coats the interior surfaces of the alveoli. This is enabled by a surface active lipo-protein complex, known as pulmonary surfactant, that modifies the surface tension at the hypophase-air interface. Surfactants also serve as physical barriers that modify the rate of gas transfer across interfaces. We develop a mathematical model to study the action of pulmonary surfactant and its determinative contributions to breathing. The model is used to explore the influence of surfactants on alveolar mechanics and on gas exchange: it relates the work of respiration at the level of the alveolus to the gas exchange rate through the changing influence of pulmonary surfactant over the breathing cycle. This work is motivated by a need to develop improved surfactant replacement therapies to treat serious medical conditions.

  20. Leaf gas exchange of mature bottomland oak trees

    Science.gov (United States)

    Rico M. Gazal; Mark E. Kubiske; Kristina F. Connor

    2009-01-01

    We determined how changes in environmental moisture affected leaf gas exchange in Nuttall (Quercus texana Buckley), overcup (Q. lyrata Walt.), and dominant and codominant swamp chestnut (Q. michauxii Nutt.) oak trees in Mississippi and Louisiana. We used canopy access towers to measure leaf level gas...

  1. Liquid-metal-gas heat exchanger for HTGR type reactors

    International Nuclear Information System (INIS)

    Werth, G.

    1980-01-01

    The aim of this study is to investigate the heat transfer characteristics of a liquid metal heat exchanger (HE) for a helium-cooled high temperature reactor. A tube-type heat exchanger is considered as well as two direct exchangers: a bubble-type heat exchanger and a heat exchanger according to the spray principle. Experiments are made in order to determine the gas content of bubble-type heat exchangers, the dependence of the droplet diameter on the nozzle diameter, the falling speed of the droplets, the velocity of the liquid jet, and the temperature variation of liquid jets. The computer codes developed for HE calculation are structured so that they may be used for gas/liquid HE, too. Each type of HE that is dealt with is designed by accousting for a technical and an economic assessment. The liquid-lead jet spray is preferred to all other types because of its small space occupied and its simple design. It shall be used in near future in the HTR by the name of lead/helium HE. (GL) [de

  2. High Temperature Gas-to-Gas Heat Exchanger Based on a Solid Intermediate Medium

    Directory of Open Access Journals (Sweden)

    R. Amirante

    2014-04-01

    Full Text Available This paper proposes the design of an innovative high temperature gas-to-gas heat exchanger based on solid particles as intermediate medium, with application in medium and large scale externally fired combined power plants fed by alternative and dirty fuels, such as biomass and coal. An optimization procedure, performed by means of a genetic algorithm combined with computational fluid dynamics (CFD analysis, is employed for the design of the heat exchanger: the goal is the minimization of its size for an assigned heat exchanger efficiency. Two cases, corresponding to efficiencies equal to 80% and 90%, are considered. The scientific and technical difficulties for the realization of the heat exchanger are also faced up; in particular, this work focuses on the development both of a pressurization device, which is needed to move the solid particles within the heat exchanger, and of a pneumatic conveyor, which is required to deliver back the particles from the bottom to the top of the plant in order to realize a continuous operation mode. An analytical approach and a thorough experimental campaign are proposed to analyze the proposed systems and to evaluate the associated energy losses.

  3. Fifty Years of Research in ARDS. Gas Exchange in Acute Respiratory Distress Syndrome.

    Science.gov (United States)

    Radermacher, Peter; Maggiore, Salvatore Maurizio; Mercat, Alain

    2017-10-15

    Acute respiratory distress syndrome (ARDS) is characterized by severe impairment of gas exchange. Hypoxemia is mainly due to intrapulmonary shunt, whereas increased alveolar dead space explains the alteration of CO 2 clearance. Assessment of the severity of gas exchange impairment is a requisite for the characterization of the syndrome and the evaluation of its severity. Confounding factors linked to hemodynamic status can greatly influence the relationship between the severity of lung injury and the degree of hypoxemia and/or the effects of ventilator settings on gas exchange. Apart from situations of rescue treatment, targeting optimal gas exchange in ARDS has become less of a priority compared with prevention of injury. A complex question for clinicians is to understand when improvement in oxygenation and alveolar ventilation is related to a lower degree or risk of injury for the lungs. In this regard, a full understanding of gas exchange mechanism in ARDS is imperative for individualized symptomatic support of patients with ARDS.

  4. Discontinuous gas exchange, water loss, and metabolism in Protaetia cretica (Cetoniinae, Scarabaeidae).

    Science.gov (United States)

    Matthews, Philip G D; White, Craig R

    2012-01-01

    Insects are at high risk of desiccation because of their small size, high surface-area-to-volume ratio, and air-filled tracheal system that ramifies throughout their bodies to transport O(2) and CO(2) to and from respiring cells. Although the tracheal system offers a high-conductance pathway for the movement of respiratory gases, it has the unintended consequence of allowing respiratory transpiration to the atmosphere. When resting, many species exchange respiratory gases discontinuously, and an early hypothesis for the origin of these discontinuous gas exchange cycles (DGCs) is that they serve to reduce respiratory water loss. In this study, we test this "hygric" hypothesis by comparing rates of CO(2) exchange and water loss among flower beetles Protaetia cretica (Cetoniinae, Scarabaeidae) breathing either continuously or discontinuously. We show that, consistent with the expectations of the hygric hypothesis, rates of total water loss are higher during continuous gas exchange than during discontinuous gas exchange and that the ratio of respiratory water loss to CO(2) exchange is lower during discontinuous gas exchange. This conclusion is in agreement with other studies of beetles and cockroaches that also support the hygric hypothesis. However, this result does not exclude other adaptive hypotheses supported by work on ants and moth pupae. This ambiguity may arise because there are multiple independent evolutionary origins of DGCs and no single adaptive function underlying their genesis. Alternatively, the observed reduction in water loss during DGCs may be a side effect of a nonadaptive gas exchange pattern that is elicited during periods of inactivity.

  5. Effects of exercise position on the ventilatory responses to exercise in chronic heart failure.

    Science.gov (United States)

    Armour, W; Clark, A L; McCann, G P; Hillis, W S

    1998-09-01

    Patients with heart failure frequently complain of orthopnoea. The objective was to assess the ventilatory response of patients with chronic heart failure during erect and supine exercise. Maximal incremental exercise testing with metabolic gas exchange measurements in erect and supine positions conducted in random order. Tertiary referral centre for cardiology. Nine patients with heart failure (aged 61.9+/-6.1 years) and 10 age matched controls (63.8+/-4.6). Metabolic gas exchange measurements. The slope of the relation between ventilation and carbon dioxide production. Ratings of perceived breathlessness during exercise. Oxygen consumption (VO2) and ventilation were higher during erect exercise at each stage in each group. Peak VO2 was [mean (SD)] 17.12 ml/kg/min (4.07) erect vs 12.92 (3.61) supine in the patients (P<0.01) and 22.62 (5.03) erect-supine vs 19.16 (3.78) erect (P<0.01) in the controls. Ratings of perceived exertion were higher in the patients at each stage, but unaffected by posture. There was no difference in the slope of the relation between ventilation and carbon dioxide production between erect and supine exercise 36.39 (6.12) erect vs 38.42 (8.89) supine for patients; 30.05 (4.52) vs 28.80 (3.96) for controls. In this group of patients during exercise, there was no change in the perception of breathlessness, nor the ventilatory response to carbon dioxide production with change in posture, although peak ventilation was greater in the erect position. The sensation of breathlessness may be related to the appropriateness of the ventilatory response to exertion rather than to the absolute ventilation.

  6. The performance of a new gas to gas heat exchanger with strip fin

    NARCIS (Netherlands)

    Wang, J.; Hirs, Gerard; Rollmann, P.

    1999-01-01

    A compact gas to gas heat exchanger needs large heat transfer areas on both fluid sides. This can be realised by adding secondary surfaces. The secondary surfaces are plate fin, strip fin, and louvered fin, etc. The fins extend the heat transfer surfaces and promote turbulence. This paper presents a

  7. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Edward Levy; Harun Bilirgen; John DuPoint

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: (1) An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing high-moisture, low rank coals. (2) Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. (3) Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. (4) Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. (5) Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. (6) Condensed flue gas water treatment needs and costs. (7) Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. (8) Results of cost-benefit studies of condensing heat exchangers.

  8. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Edward; Bilirgen, Harun; DuPont, John

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: • An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing highmoisture, low rank coals. • Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. • Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. • Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. • Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. • Condensed flue gas water treatment needs and costs. • Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. • Results of cost-benefit studies of condensing heat exchangers.

  9. Effect of carbohydrate ingestion on brain exchange of amino acids during sustained exercise in human subjects

    DEFF Research Database (Denmark)

    Blomstrand, Eva; Møller, Kirsten; Secher, Niels Henry

    2005-01-01

    occasions; either supplemented with a 6% carbohydrate solution or with flavoured water (placebo). Catheters were inserted into the right internal jugular vein and the radial artery of the non-dominant arm. The brain exchange of amino acids during exercise was calculated from the arterial-jugular venous......AIM: This study investigated the effect of prolonged exercise with and without carbohydrate intake on the brain exchange of amino acids, especially focussing on tryptophan and branched-chain amino acids (BCAA). METHODS: Five male subjects exercised for 3 h on a cycle ergometer at 200 +/- 7 W on two...... concentration difference multiplied by plasma flow. RESULTS: About 106 micromol (22 mg) of tryptophan was taken up by the brain during exercise in the placebo trial, whereas no significant uptake was observed in the carbohydrate trial. In accordance, the arterial concentration of free tryptophan increased from...

  10. Reactive oxygen species production and discontinuous gas exchange in insects

    OpenAIRE

    Boardman, Leigh; Terblanche, John S.; Hetz, Stefan K.; Marais, Elrike; Chown, Steven L.

    2011-01-01

    While biochemical mechanisms are typically used by animals to reduce oxidative damage, insects are suspected to employ a higher organizational level, discontinuous gas exchange mechanism to do so. Using a combination of real-time, flow-through respirometry and live-cell fluorescence microscopy, we show that spiracular control associated with the discontinuous gas exchange cycle (DGC) in Samia cynthia pupae is related to reactive oxygen species (ROS). Hyperoxia fails to increase mean ROS produ...

  11. Risk Based Inspection of Gas-Cooling Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Dwi Priyanta

    2017-09-01

    Full Text Available On October 2013, Pertamina Hulu Energi Offshore North West Java (PHE – ONWJ platform personnel found 93 leaking tubes locations in the finfan coolers/ gas-cooling heat exchanger. After analysis had been performed, the crack in the tube strongly indicate that stress corrosion cracking was occurred by chloride. Chloride stress corrosion cracking (CLSCC is the cracking occurred by the combined influence of tensile stress and a corrosive environment. CLSCC is the one of the most common reasons why austenitic stainless steel pipework or tube and vessels deteriorate in the chemical processing, petrochemical industries and maritime industries. In this thesis purpose to determine the appropriate inspection planning for two main items (tubes and header box in the gas-cooling heat exchanger using risk based inspection (RBI method. The result, inspection of the tubes must be performed on July 6, 2024 and for the header box inspection must be performed on July 6, 2025. In the end, RBI method can be applicated to gas-cooling heat exchanger. Because, risk on the tubes can be reduced from 4.537 m2/year to 0.453 m2/year. And inspection planning for header box can be reduced from 4.528 m2/year to 0.563 m2/year.

  12. Theoretical study of inspiratory flow waveforms during mechanical ventilation on pulmonary blood flow and gas exchange.

    Science.gov (United States)

    Niranjan, S C; Bidani, A; Ghorbel, F; Zwischenberger, J B; Clark, J W

    1999-08-01

    A lumped two-compartment mathematical model of respiratory mechanics incorporating gas exchange and pulmonary circulation is utilized to analyze the effects of square, descending and ascending inspiratory flow waveforms during mechanical ventilation. The effects on alveolar volume variation, alveolar pressure, airway pressure, gas exchange rate, and expired gas species concentration are evaluated. Advantages in ventilation employing a certain inspiratory flow profile are offset by corresponding reduction in perfusion rates, leading to marginal effects on net gas exchange rates. The descending profile provides better CO2 exchange, whereas the ascending profile is more advantageous for O2 exchange. Regional disparities in airway/lung properties create maldistribution of ventilation and a concomitant inequality in regional alveolar gas composition and gas exchange rates. When minute ventilation is maintained constant, for identical time constant disparities, inequalities in compliance yield pronounced effects on net gas exchange rates at low frequencies, whereas the adverse effects of inequalities in resistance are more pronounced at higher frequencies. Reduction in expiratory air flow (via increased airway resistance) reduces the magnitude of upstroke slope of capnogram and oxigram time courses without significantly affecting end-tidal expired gas compositions, whereas alterations in mechanical factors that result in increased gas exchanges rates yield increases in CO2 and decreases in O2 end-tidal composition values. The model provides a template for assessing the dynamics of cardiopulmonary interactions during mechanical ventilation by combining concurrent descriptions of ventilation, capillary perfusion, and gas exchange. Copyright 1999 Academic Press.

  13. Development of gas-solid direct contact heat exchanger by use of axial flow cyclone

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akihiko; Yokomine, Takehiko [Kyushu University (Japan). Interdisciplinary Graduate School of Engineering Sciences; Nagafuchi, Tatsuro [Miura Co. Ltd., Matsuyamashi (Japan)

    2004-10-01

    A heat exchanger between particulate or granular materials and gas is developed. It makes use of a swirling gas flow similar to the usual cyclone separators but the difference from them is that the swirl making gas is issued into the cyclone chamber with downward axial velocity component. After it turns the flow direction near the bottom of the chamber, the low temperature gas receives heat from high temperature particles supplied from above at the chamber's center. Through this configuration, a direct contact and quasi counter-flow heat exchange pattern is realized so that the effective recovery of heat carried by particles is achieved. A model heat exchanger was manufactured via several numerical experiments and its performances of heat exchange as well as particle recovery were examined. Attaching a small particle diffuser below the particle-feeding nozzle brought about a drastic improvement of the heat exchange performance without deteriorating the particle recovery efficiency. The outlet gas temperature much higher than the particle outlet temperature was finally obtained, which is never realized in the parallel flow heat exchanger. (author)

  14. The efficacy of fluid-gas exchange for the treatment of postvitrectomy retinal detachment.

    Science.gov (United States)

    Jang, Ji Hye; Kim, Yu Cheol; Kim, Kwang Soo

    2009-12-01

    This study was designed to evaluate the efficacy of fluid-gas exchange for the treatment of postvitrectomy retinal detachment. We retrospectively reviewed the records of 33 consecutive patients (35 eyes) who underwent fluid-gas exchange treatment for postvitrectomy retinal detachment using the two-needle pars plana approach technique. The retinal reattachment rate was 80.0% after complete intravitreal gas disappearance following the fluid-gas exchange; the overall success rate was 65.7%. Visual acuity was improved or stable in 80.0% of cases; a two-line or greater vision improvement or a best-corrected visual acuity of 0.4 or better occurred in 62.9% of cases. The success rates for superior retinal detachments and posterior pole retinal detachments were 76.5% and 85.7%, respectively. Fluid-gas exchange represents a simple and cost-effective alternative outpatient procedure for retinal reattachment without reoperation for the treatment of superior and posterior pole retinal detachments.

  15. Soil-atmosphere trace gas exchange in semiarid and arid zones.

    Science.gov (United States)

    Galbally, Ian E; Kirstine, Wayne V; Meyer, C P Mick; Wang, Ying Ping

    2008-01-01

    A review is presented on trace gas exchange of CH4, CO, N2O, and NOx arising from agriculture and natural sources in the world's semiarid and arid zones due to soil processes. These gases are important contributors to the radiative forcing and the chemistry of the atmosphere. Quantitative information is summarized from the available studies. Between 5 and 40% of the global soil-atmosphere exchange for these gases (CH4, CO, N2O, and NOx) may occur in semiarid and arid zones, but for each of these gases there are fewer than a dozen studies to support the individual estimates, and these are from a limited number of locations. Significant differences in the biophysical and chemical processes controlling these trace gas exchanges are identified through the comparison of semiarid and arid zones with the moist temperate or wet/dry savanna land regions. Therefore, there is a poorly quantified understanding of the contribution of these regions to the global trace gas cycles and atmospheric chemistry. More importantly, there is a poor understanding of the feedback between these exchanges, global change, and regional land use and air pollution issues. A set of research issues is presented.

  16. Influence of smoking and obesity on alveolar-arterial gas pressure differences and dead space ventilation at rest and peak exercise in healthy men and women.

    Science.gov (United States)

    Gläser, Sven; Ittermann, Till; Koch, Beate; Schäper, Christoph; Felix, Stephan B; Völzke, Henry; Könemann, Raik; Ewert, Ralf; Hansen, James E

    2013-06-01

    Besides exercise intolerance, the assessment of ventilatory and perfusion adequacy allows additional insights in the disease pathophysiology in many cardiovascular or pulmonary diseases. Valid measurements of dead space/tidal volume ratios (VD/VT), arterial (a') - end-tidal (et) carbon dioxide (CO2) and oxygen (O2) pressure differences (p(a'-et)CO2) and (p(et-a')O2), and alveolar (A)-a' O2 pressure differences (p(A-a')O2) require using blood samples in addition to gas exchange analyses on a breath-by-breath-basis. Smoking and nutritional status are also important factors in defining disorders. Using a large healthy population we considered the impact of these factors to develop useful prediction equations. Incremental cycle exercise protocols were applied to apparently healthy volunteer adults who did not have structural heart disease or echocardiographic or lung function pathologies. Age, height, weight, and smoking were analysed for their influence on the target parameters in each gender. Reference values were determined by regression analyses. The final study sample consisted of 476 volunteers (190 female), aged 25-85 years. Smoking significantly influences p(A-a')O2 and p(a'-et)CO2 at rest and peak exercise, and VD/VT during exercise. Obesity influences upper limits of VD/VT, p(a'-et)CO2 and p(et-a')O2 at rest as well as p(A-a')O2 and p(et-a')O2 at exercise. Reference equations for never-smokers as well as for apparently healthy smokers considering influencing factors are given. Gender, age, height, weight, and smoking significantly influence gas exchange. Considering all of these factors this study provides a comprehensive set of reference equations derived from a large number of participants of a population-based study. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Measurements of pulmonary gas exchange efficiency using expired gas and oximetry: results in normal subjects.

    Science.gov (United States)

    West, John B; Wang, Daniel L; Prisk, G Kim

    2018-04-01

    We are developing a novel, noninvasive method for measuring the efficiency of pulmonary gas exchange in patients with lung disease. The patient wears an oximeter, and we measure the partial pressures of oxygen and carbon dioxide in inspired and expired gas using miniature analyzers. The arterial Po 2 is then calculated from the oximeter reading and the oxygen dissociation curve, using the end-tidal Pco 2 to allow for the Bohr effect. This calculation is only accurate when the oxygen saturation is ideal alveolar Po 2 minus the measured arterial Po 2 . That measurement requires an arterial blood sample. The present study suggests that this noninvasive procedure will be valuable in assessing the degree of impaired gas exchange in patients with lung disease.

  18. Gas exchange and chlorophyll a fluorescence parameters of ornamental bromeliads

    Directory of Open Access Journals (Sweden)

    Karina Gonçalves da Silva

    2017-10-01

    Full Text Available Gas exchange and chlorophyll a fluorescence are widely used in physiological and ecological studies; however, few studies have used these techniques with ornamental plants. This study tested the potential contribution of gas exchange and chlorophyll a fluorescence to evaluate the water and nutrients uptake by the tank and root system of epiphyte bromeliad Guzmania lingulata. For this purpose, we conducted an experiment with different water regime and another with different concentrations of nitrogen. The experiments were: 1 - Watering: Control (application of water into Tank and Root, Tank (watering into Tank, Root (watering Root and Drought (water suspension during the 90 days of experimentation and 2 - Nitrogen: Plants fertilized with Hoagland and Arnon nutrient solution exclusively into Tank or Root with nitrogen concentrations of control and 2.62 or 5.34 mM N applied as urea. The Fv /Fm ratio allowed comparing the treatments between experiments, demonstrating that Root and Tank both have the capacity to maintain G. lingulata photosynthetic activity and growth, while Drought treatment (water suspension was the limiting factor for energy conversion efficiency of PSII. However, gas exchange was more permissive as a parameter for comparing treatments in the nitrogen experiment, providing important information about the general aspects of the photosynthetic process in the watering experiment. Both gas exchange and chlorophyll a fluorescence can support the evaluation of G. lingulata physiological status and can be useful tools in ornamental horticultural studies.

  19. Improving respiration measurements with gas exchange analyzers.

    Science.gov (United States)

    Montero, R; Ribas-Carbó, M; Del Saz, N F; El Aou-Ouad, H; Berry, J A; Flexas, J; Bota, J

    2016-12-01

    Dark respiration measurements with open-flow gas exchange analyzers are often questioned for their low accuracy as their low values often reach the precision limit of the instrument. Respiration was measured in five species, two hypostomatous (Vitis Vinifera L. and Acanthus mollis) and three amphistomatous, one with similar amount of stomata in both sides (Eucalyptus citriodora) and two with different stomata density (Brassica oleracea and Vicia faba). CO 2 differential (ΔCO 2 ) increased two-fold with no change in apparent R d , when the two leaves with higher stomatal density faced outside. These results showed a clear effect of the position of stomata on ΔCO 2 . Therefore, it can be concluded that leaf position is important to guarantee the improvement of respiration measurements increasing ΔCO 2 without affecting the respiration results by leaf or mass units. This method will help to increase the accuracy of leaf respiration measurements using gas exchange analyzers. Copyright © 2016 Elsevier GmbH. All rights reserved.

  20. Virtual Protein Purification: A Simple Exercise to Introduce pH as A Parameter That Effects Ion Exchange Chromatography

    Science.gov (United States)

    Clark, Daniel D.; Edwards, Daniel J.

    2018-01-01

    This article describes a simple exercise using a free, easy-to-use, established online program. The exercise helps to reinforce protein purification concepts and introduces undergraduates to pH as a parameter that affects anion-exchange chromatography. The exercise was tested with biochemistry majors at California State University-Chico. Given the…

  1. Hydraulics and gas exchange recover more rapidly from severe drought stress in small pot-grown grapevines than in field-grown plants.

    Science.gov (United States)

    Romero, Pascual; Botía, Pablo; Keller, Markus

    2017-09-01

    quickly following restoration of Ψ s , although gas exchange recovery did not directly depend on recovery of K canopy . In field-grown vines, recovery of water status, gas exchange and hydraulic functionality was slower than in pot-grown plants, and low g s after rewatering was related to sustained decreased K plant , K canopy and K shoot and lower water transport to leaves. These results suggest that caution should be exercised when scaling up conclusions from experiments with small pot-grown plants to field conditions. Copyright © 2017 Elsevier GmbH. All rights reserved.

  2. Wave Attenuation and Gas Exchange Velocity in Marginal Sea Ice Zone

    Science.gov (United States)

    Bigdeli, A.; Hara, T.; Loose, B.; Nguyen, A. T.

    2018-03-01

    The gas transfer velocity in marginal sea ice zones exerts a strong control on the input of anthropogenic gases into the ocean interior. In this study, a sea state-dependent gas exchange parametric model is developed based on the turbulent kinetic energy dissipation rate. The model is tuned to match the conventional gas exchange parametrization in fetch-unlimited, fully developed seas. Next, fetch limitation is introduced in the model and results are compared to fetch limited experiments in lakes, showing that the model captures the effects of finite fetch on gas exchange with good fidelity. Having validated the results in fetch limited waters such as lakes, the model is next applied in sea ice zones using an empirical relation between the sea ice cover and the effective fetch, while accounting for the sea ice motion effect that is unique to sea ice zones. The model results compare favorably with the available field measurements. Applying this parametric model to a regional Arctic numerical model, it is shown that, under the present conditions, gas flux into the Arctic Ocean may be overestimated by 10% if a conventional parameterization is used.

  3. Foliar trichomes, boundary layers, and gas exchange in 12 species of epiphytic Tillandsia (Bromeliaceae).

    Science.gov (United States)

    Benz, Brett W; Martin, Craig E

    2006-04-01

    We examined the relationships between H2O and CO2 gas exchange parameters and leaf trichome cover in 12 species of Tillandsia that exhibit a wide range in trichome size and trichome cover. Previous investigations have hypothesized that trichomes function to enhance boundary layers around Tillandsioid leaves thereby buffering the evaporative demand of the atmosphere and retarding transpirational water loss. Data presented herein suggest that trichome-enhanced boundary layers have negligible effects on Tillandsia gas exchange, as indicated by the lack of statistically significant relationships in regression analyses of gas exchange parameters and trichome cover. We calculated trichome and leaf boundary layer components, and their associated effects on H2O and CO2 gas exchange. The results further indicate trichome-enhanced boundary layers do not significantly reduce transpirational water loss. We conclude that although the trichomes undoubtedly increase the thickness of the boundary layer, the increase due to Tillandsioid trichomes is inconsequential in terms of whole leaf boundary layers, and any associated reduction in transpirational water loss is also negligible within the whole plant gas exchange pathway.

  4. Leaf gas exchange in the frankincense tree (Boswellia papyrifera) of African dry woodlands

    NARCIS (Netherlands)

    Mengistu, T.; Sterck, F.J.; Fetene, M.; Tadesse, W.; Bongers, F.

    2011-01-01

    A conceptual model was tested for explaining environmental and physiological effects on leaf gas exchange in the deciduous dry tropical woodland tree Boswellia papyrifera (Del.) Hochst. For this species we aimed at (i) understanding diurnal patterns in leaf gas exchange, (ii) exploring cause–effect

  5. A meta-analysis of leaf gas exchange and water status responses to drought.

    Science.gov (United States)

    Yan, Weiming; Zhong, Yangquanwei; Shangguan, Zhouping

    2016-02-12

    Drought is considered to be one of the most devastating natural hazards, and it is predicted to become increasingly frequent and severe in the future. Understanding the plant gas exchange and water status response to drought is very important with regard to future climate change. We conducted a meta-analysis based on studies of plants worldwide and aimed to determine the changes in gas exchange and water status under different drought intensities (mild, moderate and severe), different photosynthetic pathways (C3 and C4) and growth forms (herbs, shrubs, trees and lianas). Our results were as follows: 1) drought negatively impacted gas exchange and water status, and stomatal conductance (gs) decreased more than other physiological traits and declined to the greatest extent in shrubs and C3 plants. Furthermore, C4 plants had an advantage compared to C3 plants under the same drought conditions. 2) The decrease in gs mainly reduced the transpiration rate (Tr), and gs could explain 55% of the decrease in the photosynthesis (A) and 74% of the decline in Tr. 3). Finally, gas exchange showed a close relationship with the leaf water status. Our study provides comprehensive information about the changes in plant gas exchange and water status under drought.

  6. [Phylogeny of gas exchange systems].

    Science.gov (United States)

    Jürgens, K D; Gros, G

    2002-04-01

    Several systems of gas transport have developed during evolution, all of which are able to sufficiently supply oxygen to the tissues and eliminate the CO2 produced by the metabolism, in spite of great distances between the environment and the individual cells of the tissues. Almost all these systems utilize a combination of convection and diffusion steps. Convection achieves an efficient transport of gas over large distances, but requires energy and cannot occur across tissue barriers. Diffusion, on the other hand, achieves gas transport across barriers, but requires optimization of diffusion paths and diffusion areas. When two convectional gas flows are linked via a diffusional barrier (gas/fluid in the case of the avian lung, fluid/fluid in the case of gills), the directions in which the respective convectional movements pass each other are important determinants of gas exchange efficiency (concurrent, countercurrent and cross-current systems). The tracheal respiration found in insects has the advantage of circumventing the convective gas transport step in the blood, thereby avoiding the high energy expenditure of circulatory systems. This is made possible by a system of tracheae, ending in tracheoles, that reaches from the body surface to every cell within the body. The last step of gas transfer in these animals occurs by diffusion from the tracheoles ("air capillaries") to the mitochondria of cells. The disadvantage is that the tracheal system occupies a substantial fraction of body volume and that, due to limited mechanical stability of tracheal walls, this system would not be able to operate under conditions of high hydrostatic pressures, i. e. in large animals. Respiration in an "open" system, i. e. direct exposure of the diffusional barrier to the environmental air, eliminates the problem of bringing the oxygen to the barrier by convection, as is necessary in the avian and mammalian lung, in the insects' tracheal system and in the gills. An open system is

  7. The role of the spiracles in gas exchange during development of Samia cynthia (Lepidoptera, Saturniidae).

    Science.gov (United States)

    Hetz, Stefan K

    2007-12-01

    Spiracles and the tracheal system of insects allow effective delivery of respiratory gases. During development, holometabolous insects encounter large changes in the functional morphology of gas exchange structures. To investigate changes in respiratory patterns during development, CO2-release was measured in larvae, pre-pupae and pupae of Samia cynthia (Lepidoptera, Saturniidae). Gas exchange patterns showed great variability. Caterpillars had high metabolic rates and released carbon dioxide continuously. Pre-pupae and pupae showed typical discontinuous gas exchange cycles (DGC) at reduced metabolic rates. Changes in gas exchange patterns can partly be explained with low metabolic rates during pupation. Sequential blocking of spiracles in pre-pupae and pupae reduced spiracle conductance with tracheal conductance remaining unaffected. Analysis of gas exchange patterns indicates that caterpillars and pre-pupae use more than 14 spiracles simultaneously while pupae only use 8 to 10 spiracles. Total conductance is not a simple multiple of single spiracles, but may be gradually adaptable to gas exchange demands. Surprisingly, moth pupae showed a DGC if all except one spiracle were blocked. The huge conductance of single spiracles is discussed as a pre-adaptation to high metabolic demands at the beginning and the end of the pupal as well as in the adult stage.

  8. Gas exchange patterns and water loss rates in the Table Mountain cockroach, Aptera fusca (Blattodea: Blaberidae).

    Science.gov (United States)

    Groenewald, Berlizé; Bazelet, Corinna S; Potter, C Paige; Terblanche, John S

    2013-10-15

    The importance of metabolic rate and/or spiracle modulation for saving respiratory water is contentious. One major explanation for gas exchange pattern variation in terrestrial insects is to effect a respiratory water loss (RWL) saving. To test this, we measured the rates of CO2 and H2O release ( and , respectively) in a previously unstudied, mesic cockroach, Aptera fusca, and compared gas exchange and water loss parameters among the major gas exchange patterns (continuous, cyclic, discontinuous gas exchange) at a range of temperatures. Mean , and per unit did not differ among the gas exchange patterns at all temperatures (P>0.09). There was no significant association between temperature and gas exchange pattern type (P=0.63). Percentage of RWL (relative to total water loss) was typically low (9.79±1.84%) and did not differ significantly among gas exchange patterns at 15°C (P=0.26). The method of estimation had a large impact on the percentage of RWL, and of the three techniques investigated (traditional, regression and hyperoxic switch), the traditional method generally performed best. In many respects, A. fusca has typical gas exchange for what might be expected from other insects studied to date (e.g. , , RWL and cuticular water loss). However, we found for A. fusca that expressed as a function of metabolic rate was significantly higher than the expected consensus relationship for insects, suggesting it is under considerable pressure to save water. Despite this, we found no consistent evidence supporting the conclusion that transitions in pattern type yield reductions in RWL in this mesic cockroach.

  9. Investigation and optimization of the depth of flue gas heat recovery in surface heat exchangers

    Science.gov (United States)

    Bespalov, V. V.; Bespalov, V. I.; Melnikov, D. V.

    2017-09-01

    Economic issues associated with designing deep flue gas heat recovery units for natural gas-fired boilers are examined. The governing parameter affecting the performance and cost of surface-type condensing heat recovery heat exchangers is the heat transfer surface area. When firing natural gas, the heat recovery depth depends on the flue gas temperature at the condenser outlet and determines the amount of condensed water vapor. The effect of the outlet flue gas temperature in a heat recovery heat exchanger on the additionally recovered heat power is studied. A correlation has been derived enabling one to determine the best heat recovery depth (or the final cooling temperature) maximizing the anticipated reduced annual profit of a power enterprise from implementation of energy-saving measures. Results of optimization are presented for a surface-type condensing gas-air plate heat recovery heat exchanger for the climatic conditions and the economic situation in Tomsk. The predictions demonstrate that it is economically feasible to design similar heat recovery heat exchangers for a flue gas outlet temperature of 10°C. In this case, the payback period for the investment in the heat recovery heat exchanger will be 1.5 years. The effect of various factors on the optimal outlet flue gas temperature was analyzed. Most climatic, economical, or technological factors have a minor effect on the best outlet temperature, which remains between 5 and 20°C when varying the affecting factors. The derived correlation enables us to preliminary estimate the outlet (final) flue gas temperature that should be used in designing the heat transfer surface of a heat recovery heat exchanger for a gas-fired boiler as applied to the specific climatic conditions.

  10. Radon gas-exchange rate through the interface sea atmosphere in the coast

    International Nuclear Information System (INIS)

    Duenas, C.; Fernandez, M.C.; Perez Martinez, M.

    1985-01-01

    The Rn gas exchange velocity through the interface sea atmosphere has been estimated. Our measurements have been made in a sampler station located in Malaga bay, obtaining a mean value of 0.45 m/d. The corresponding magnitude of the thickness of boundary layer is 316μ. Experimental results are discussed. No clear relationship can be found between the gas exchange rate and wind speed. (author)

  11. Using Riverboat-Mounted Eddy Covariance for Direct Measurements of Air-water Gas Exchange in Amazonia

    Science.gov (United States)

    Miller, S. D.; Freitas, H.; Read, E.; Goulden, M. L.; Rocha, H.

    2007-12-01

    Gas evasion from Amazonian rivers and lakes to the atmosphere has been estimated to play an important role in the regional budget of carbon dioxide (Richey et al., 2002) and the global budget of methane (Melack et al., 2004). These flux estimates were calculated by combining remote sensing estimates of inundation area with water-side concentration gradients and gas transfer rates (piston velocities) estimated primarily from floating chamber measurements (footprint ~1 m2). The uncertainty in these fluxes was large, attributed primarily to uncertainty in the gas exchange parameterization. Direct measurements of the gas exchange coefficient are needed to improve the parameterizations in these environments, and therefore reduce the uncertainty in fluxes. The micrometeorological technique of eddy covariance is attractive since it is a direct measurement of gas exchange that samples over a much larger area than floating chambers, and is amenable to use from a moving platform. We present eddy covariance carbon dioxide exchange measurements made using a small riverboat in rivers and lakes in the central Amazon near Santarem, Para, Brazil. Water-side carbon dioxide concentration was measured in situ, and the gas exchange coefficient was calculated. We found the piston velocity at a site on the Amazon River to be similar to existing ocean-based parameterizations, whereas the piston velocity at a site on the Tapajos River was roughly a factor 5 higher. We hypothesize that the enhanced gas exchange at the Tapajos site was due to a shallow upwind fetch. Our results demonstrate the feasibility of boat-based eddy covariance on these rivers, and also the utility of a mobile platform to investigate spatial variability of gas exchange.

  12. Exertional dyspnoea in interstitial lung diseases: the clinical utility of cardiopulmonary exercise testing

    Directory of Open Access Journals (Sweden)

    Matteo Bonini

    2017-02-01

    Full Text Available Interstitial lung diseases (ILDs represent a heterogeneous group of pathologies characterised by alveolar and interstitial damage, pulmonary inflammation (usually associated with fibrosis, decreased lung function and impaired gas exchange, which can be attributed to either a known or an unknown aetiology. Dyspnoea is one of the most common and disabling symptoms in patients with ILD, significantly impacting quality of life. The mechanisms causing dyspnoea are complex and not yet fully understood. However, it is recognised that dyspnoea occurs when there is an imbalance between the central respiratory efferent drive and the response of the respiratory musculature. The respiratory derangement observed in ILD patients at rest is even more evident during exercise. Pathophysiological mechanisms responsible for exertional dyspnoea and reduced exercise tolerance include altered respiratory mechanics, impaired gas exchange, cardiovascular abnormalities and peripheral muscle dysfunction. This review describes the respiratory physiology of ILD, both at rest and during exercise, and aims to provide comprehensive and updated evidence on the clinical utility of the cardiopulmonary exercise test in the assessment and management of these pathological entities. In addition, the role of exercise training and pulmonary rehabilitation programmes in the ILD population is addressed.

  13. Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler

    Science.gov (United States)

    Cao, Weixue; Liu, Fengguo; You, Xue-yi

    2018-01-01

    Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.

  14. Water use in forest canopy black cherry trees and its relationship to leaf gas exchange and environment

    Science.gov (United States)

    B. J. Joyce; K. C. Steiner; J. M. Skelly

    1996-01-01

    Models of canopy gas exchange are needed to connect leaf-level measurement to higher scales. Because of the correspondence between leaf gas exchange and water use, it may be possible to predict variation in leaf gas exchange at the canopy level by monitoring rates of branch water use.

  15. Effect of hypoxia and hyperoxia on exercise performance in healthy individuals and in patients with pulmonary hypertension: a systematic review.

    Science.gov (United States)

    Ulrich, Silvia; Schneider, Simon R; Bloch, Konrad E

    2017-12-01

    Exercise performance is determined by oxygen supply to working muscles and vital organs. In healthy individuals, exercise performance is limited in the hypoxic environment at altitude, when oxygen delivery is diminished due to the reduced alveolar and arterial oxygen partial pressures. In patients with pulmonary hypertension (PH), exercise performance is already reduced near sea level due to impairments of the pulmonary circulation and gas exchange, and, presumably, these limitations are more pronounced at altitude. In studies performed near sea level in healthy subjects, as well as in patients with PH, maximal performance during progressive ramp exercise and endurance of submaximal constant-load exercise were substantially enhanced by breathing oxygen-enriched air. Both in healthy individuals and in PH patients, these improvements were mediated by a better arterial, muscular, and cerebral oxygenation, along with a reduced sympathetic excitation, as suggested by the reduced heart rate and alveolar ventilation at submaximal isoloads, and an improved pulmonary gas exchange efficiency, especially in patients with PH. In summary, in healthy individuals and in patients with PH, alterations in the inspiratory Po 2 by exposure to hypobaric hypoxia or normobaric hyperoxia reduce or enhance exercise performance, respectively, by modifying oxygen delivery to the muscles and the brain, by effects on cardiovascular and respiratory control, and by alterations in pulmonary gas exchange. The understanding of these physiological mechanisms helps in counselling individuals planning altitude or air travel and prescribing oxygen therapy to patients with PH.

  16. Effects of respiratory rate and tidal volume on gas exchange in total liquid ventilation.

    Science.gov (United States)

    Bull, Joseph L; Tredici, Stefano; Fujioka, Hideki; Komori, Eisaku; Grotberg, James B; Hirschl, Ronald B

    2009-01-01

    Using a rabbit model of total liquid ventilation (TLV), and in a corresponding theoretical model, we compared nine tidal volume-respiratory rate combinations to identify a ventilator strategy to maximize gas exchange, while avoiding choked flow, during TLV. Nine different ventilation strategies were tested in each animal (n = 12): low [LR = 2.5 breath/min (bpm)], medium (MR = 5 bpm), or high (HR = 7.5 bpm) respiratory rates were combined with a low (LV = 10 ml/kg), medium (MV = 15 ml/kg), or high (HV = 20 ml/kg) tidal volumes. Blood gases and partial pressures, perfluorocarbon gas content, and airway pressures were measured for each combination. Choked flow occurred in all high respiratory rate-high volume animals, 71% of high respiratory rate-medium volume (HRMV) animals, and 50% of medium respiratory rate-high volume (MRHV) animals but in no other combinations. Medium respiratory rate-medium volume (MRMV) resulted in the highest gas exchange of the combinations that did not induce choke. The HRMV and MRHV animals that did not choke had similar or higher gas exchange than MRMV. The theory predicted this behavior, along with spatial and temporal variations in alveolar gas partial pressures. Of the combinations that did not induce choked flow, MRMV provided the highest gas exchange. Alveolar gas transport is diffusion dominated and rapid during gas ventilation but is convection dominated and slow during TLV. Consequently, the usual alveolar gas equation is not applicable for TLV.

  17. Oxo-exchange of gas-phase uranyl, neptunyl, and plutonyl with water and methanol.

    Science.gov (United States)

    Lucena, Ana F; Odoh, Samuel O; Zhao, Jing; Marçalo, Joaquim; Schreckenbach, Georg; Gibson, John K

    2014-02-17

    A challenge in actinide chemistry is activation of the strong bonds in the actinyl ions, AnO2(+) and AnO2(2+), where An = U, Np, or Pu. Actinyl activation in oxo-exchange with water in solution is well established, but the exchange mechanisms are unknown. Gas-phase actinyl oxo-exchange is a means to probe these processes in detail for simple systems, which are amenable to computational modeling. Gas-phase exchange reactions of UO2(+), NpO2(+), PuO2(+), and UO2(2+) with water and methanol were studied by experiment and density functional theory (DFT); reported for the first time are experimental results for UO2(2+) and for methanol exchange, as well as exchange rate constants. Key findings are faster exchange of UO2(2+) versus UO2(+) and faster exchange with methanol versus water; faster exchange of UO2(+) versus PuO2(+) was quantified. Computed potential energy profiles (PEPs) are in accord with the observed kinetics, validating the utility of DFT to model these exchange processes. The seemingly enigmatic result of faster exchange for uranyl, which has the strongest oxo-bonds, may reflect reduced covalency in uranyl as compared with plutonyl.

  18. Plant mineral nutrition, gas exchange and photosynthesis in space: A review

    Science.gov (United States)

    Wolff, S. A.; Coelho, L. H.; Zabrodina, M.; Brinckmann, E.; Kittang, A.-I.

    2013-02-01

    Successful growth and development of higher plants in space rely on adequate availability and uptake of water and nutrients, and efficient energy distribution through photosynthesis and gas exchange. In the present review, literature has been reviewed to assemble the relevant knowledge within space plant research for future planetary missions. Focus has been on fractional gravity, space radiation, magnetic fields and ultimately a combined effect of these factors on gas exchange, photosynthesis and transport of water and solutes. Reduced gravity prevents buoyancy driven thermal convection in the physical environment around the plant and alters transport and exchange of gases and liquids between the plant and its surroundings. In space experiments, indications of root zone hypoxia have frequently been reported, but studies on the influences of the space environment on plant nutrition and water transport are limited or inconclusive. Some studies indicate that uptake of potassium is elevated when plants are grown under microgravity conditions. Based on the current knowledge, gas exchange, metabolism and photosynthesis seem to work properly in space when plants are provided with a well stirred atmosphere and grown at moderate light levels. Effects of space radiation on plant metabolism, however, have not been studied so far in orbit. Ground experiments indicated that shielding from the Earth's magnetic field alters plant gas exchange and metabolism, though more studies are required to understand the effects of magnetic fields on plant growth. It has been shown that plants can grow and reproduce in the space environment and adapt to space conditions. However, the influences of the space environment may result in a long term effect over multiple generations or have an impact on the plants' role as food and part of a regenerative life support system. Suggestions for future plant biology research in space are discussed.

  19. Analysis of Ion-Exchange Resin Capability of the RSG-GAS Demineralized Water System (GCA01)

    International Nuclear Information System (INIS)

    Diyah Erlina Lestari; Setyo Budi Utomo; Harsono

    2012-01-01

    The Demineralized water system (GCA01) is a system which is function to process raw water to be demineralized water using ion exchange resin unit consisting of a column of cation exchange resins, anion exchange resin column and the column resin mix bed. After certain time the ion exchange resins to be saturated so that is needed regeneration. The RSG-GAS demineralized water system (GCA01) not operated continuously and indication of when does an ion exchange resin regeneration on The RSG-GAS demineralized water system (GCA01) is the water conductivity from anion exchange resin column output indicates ≥ 5μS/cm. Analysis of capability of the ion exchange resin demineralized water system (GCA01) line I has been performed. The analysis was done by comparing the time required in the system operating cycle of regeneration to the next regeneration during the period 2011 and 2012. From the results of the analysis showed the cycle regeneration time is varies. This shows that ion exchange resin capability of the RSG-GAS demineralized water system (GCA01) is varies depending on the raw water quality and success of the regeneration ion exchange resin. (author)

  20. Optical methods to study the gas exchange processes in large diesel engines

    Energy Technology Data Exchange (ETDEWEB)

    Gros, S.; Hattar, C. [Wartsila Diesel International Oy, Vaasa (Finland); Hernberg, R.; Vattulainen, J. [Tampere Univ. of Technology, Tampere (Finland). Plasma Technology Lab.

    1996-12-01

    To be able to study the gas exchange processes in realistic conditions for a single cylinder of a large production-line-type diesel engine, a fast optical absorption spectroscopic method was developed. With this method line-of-sight UV-absorption of SO{sub 2} contained in the exhaust gas was measured as a function of time in the exhaust port area in a continuously fired medium speed diesel engine type Waertsilae 6L20. SO{sub 2} formed during the combustion from the fuel contained sulphur was used as a tracer to study the gas exchange as a function of time in the exhaust channel. In this case of a 4-stroke diesel engine by assuming a known concentration of SO{sub 2} in the exhaust gas after exhaust valve opening and before inlet and exhaust valve overlap period, the measured optical absorption was used to determine the gas density and further the instantaneous exhaust gas temperature during the exhaust cycle. (author)

  1. Recovery benefits of using a heat and moisture exchange mask during sprint exercise in cold temperatures.

    Science.gov (United States)

    Seifert, John G; Frost, Jeremy; St Cyr, John A

    2017-01-01

    Breathing cold air can lead to bronchoconstriction and peripheral vasoconstriction, both of which could impact muscular performance by affecting metabolic demands during exercise. Successful solutions dealing with these physiological changes during exercise in the cold has been lacking; therefore, we investigated the influence of a heat and moisture exchange mask during exercise in the cold. There were three trial arms within this study: wearing the heat and moisture exchange mask during the rest periods in the cold, no-mask application during the rest periods in the cold, and a trial at room temperature (22°C). Eight subjects cycled in four 35 kJ sprint sessions with each session separated by 20 min rest period. Workload was 4% of body mass. Mean sprint times were faster with heat and moisture exchange mask and room temperature trial than cold, no-mask trial (133.8 ± 8.6, 134.9 ± 8.8, and 138.0 ± 8.4 s (p = 0.001)). Systolic blood pressure and mean arterial pressure were greater during the cold trial with no mask (15% and 13%, respectively), and heart rate was 10 bpm less during the third rest or recovery period during cold, no mask compared to the heat and moisture exchange mask and room temperature trials. Subjects demonstrated significant decreases in vital capacity and peak expiratory flow rate during the cold with no mask applied during the rest periods. These negative responses to cold exposure were alleviated by the use of a heat and moisture exchange mask worn during the rest intervals by minimizing cold-induced temperature stress on the respiratory system with subsequent maintenance of cardiovascular function.

  2. BOREAS TE-04 Gas Exchange Data from Boreal Tree Species

    Data.gov (United States)

    National Aeronautics and Space Administration — Contains TE-04 data on gas exchange studies of photosynthesis, respiration and stomatal conductance of boreal forest species using the MPH-1000 system.

  3. Air-water Gas Exchange Rates on a Large Impounded River Measured Using Floating Domes (Poster)

    Science.gov (United States)

    Mass balance models of dissolved gases in rivers typically serve as the basis for whole-system estimates of greenhouse gas emission rates. An important component of these models is the exchange of dissolved gases between air and water. Controls on gas exchange rates (K) have be...

  4. Extracorporeal gas exchange and spontaneous breathing for the treatment of acute respiratory distress syndrome: an alternative to mechanical ventilation?*.

    Science.gov (United States)

    Langer, Thomas; Vecchi, Vittoria; Belenkiy, Slava M; Cannon, Jeremy W; Chung, Kevin K; Cancio, Leopoldo C; Gattinoni, Luciano; Batchinsky, Andriy I

    2014-03-01

    Venovenous extracorporeal gas exchange is increasingly used in awake, spontaneously breathing patients as a bridge to lung transplantation. Limited data are available on a similar use of extracorporeal gas exchange in patients with acute respiratory distress syndrome. The aim of this study was to investigate the use of extracorporeal gas exchange in awake, spontaneously breathing sheep with healthy lungs and with acute respiratory distress syndrome and describe the interactions between the native lung (healthy and diseased) and the artificial lung (extracorporeal gas exchange) in this setting. Laboratory investigation. Animal ICU of a governmental laboratory. Eleven awake, spontaneously breathing sheep on extracorporeal gas exchange. Sheep were studied before (healthy lungs) and after the induction of acute respiratory distress syndrome via IV injection of oleic acid. Six gas flow settings (1-10 L/min), resulting in different amounts of extracorporeal CO2 removal (20-100% of total CO2 production), were tested in each animal before and after the injury. Respiratory variables and gas exchange were measured for every gas flow setting. Both healthy and injured sheep reduced minute ventilation according to the amount of extracorporeal CO2 removal, up to complete apnea. However, compared with healthy sheep, sheep with acute respiratory distress syndrome presented significantly increased esophageal pressure variations (25 ± 9 vs 6 ± 3 cm H2O; p 80% of total CO2 production). Spontaneous ventilation of both healthy sheep and sheep with acute respiratory distress syndrome can be controlled via extracorporeal gas exchange. If this holds true in humans, extracorporeal gas exchange could be used in awake, spontaneously breathing patients with acute respiratory distress syndrome to support gas exchange. A deeper understanding of the pathophysiology of spontaneous breathing during acute respiratory distress syndrome is however warranted in order to be able to propose

  5. Auxiliary heat exchanger for a gas-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Ecker, H.; Gasch, K.; Lischer, R.; Spilker, H.

    1978-01-01

    The proposal concerns the design configuration of the individual components of a heat exchanger with circular cross-section, being placed within a lined pod of the concrete shell of the pressure vessel. The heat exchanger has got a vertical cooler installed below the circulator. The components are arranged in such manner that the access to the pipe lines for in-service inspections is assured. Uniform velocity distribution of the gas streaming into the cooler from below is to be achieved. (GL) 891 GL/GL 892 MKO [de

  6. Modelling Age- and Density-Related Gas Exchange of Picea abies Canopies in the Fichtelgebirge, Germany

    OpenAIRE

    Falge, Eva; Tennhunen, John D.; Ryel, Ronald J.; Alsheimer, Martina; Köstner, Barbara

    2000-01-01

    International audience; Differences in canopy exchange of water and carbon dioxide that occur due to changes in tree structure and density in montane Norway spruce stands of Central Germany were analyzed with a three dimensional microclimate and gas exchange model STANDFLUX. The model was used to calculate forest radiation absorption, the net photosynthesis and transpiration of single trees, and gas exchange of tree canopies. Model parameterizations were derived for six stands of Picea abies ...

  7. Differences in gas exchange contribute to habitat differentiation in Iberian columbines from contrasting light and water environments.

    Science.gov (United States)

    Jaime, R; Serichol, C; Alcántara, J M; Rey, P J

    2014-03-01

    During photosynthesis, respiration and transpiration, gas exchange occurs via the stomata and so plants face a trade-off between maximising photosynthesis while minimising transpiration (expressed as water use efficiency, WUE). The ability to cope with this trade-off and regulate photosynthetic rate and stomatal conductance may be related to niche differentiation between closely related species. The present study explored this as a possible mechanism for habitat differentiation in Iberian columbines. The roles of irradiance and water stress were assessed to determine niche differentiation among Iberian columbines via distinct gas exchange processes. Photosynthesis-irradiance curves (P-I curves) were obtained for four taxa, and common garden experiments were conducted to examine plant responses to water and irradiance stress, by measuring instantaneous gas exchange and plant performance. Gas exchange was also measured in ten individuals using two to four field populations per taxon. The taxa had different P-I curves and gas exchange in the field. At the species level, water stress and irradiance explained habitat differentiation. Within each species, a combination of irradiance and water stress explained the between-subspecies habitat differentiation. Despite differences in stomatal conductance and CO2 assimilation, taxa did not have different WUE under field conditions, which suggests that the environment equally modifies photosynthesis and transpiration. The P-I curves, gas exchange in the field and plant responses to experimental water and irradiance stresses support the hypothesis that habitat differentiation is associated with differences among taxa in tolerance to abiotic stress mediated by distinct gas exchange responses. © 2013 German Botanical Society and The Royal Botanical Society of the Netherlands.

  8. Direct analysis of ultra-trace semiconductor gas by inductively coupled plasma mass spectrometry coupled with gas to particle conversion-gas exchange technique.

    Science.gov (United States)

    Ohata, Masaki; Sakurai, Hiromu; Nishiguchi, Kohei; Utani, Keisuke; Günther, Detlef

    2015-09-03

    An inductively coupled plasma mass spectrometry (ICPMS) coupled with gas to particle conversion-gas exchange technique was applied to the direct analysis of ultra-trace semiconductor gas in ambient air. The ultra-trace semiconductor gases such as arsine (AsH3) and phosphine (PH3) were converted to particles by reaction with ozone (O3) and ammonia (NH3) gases within a gas to particle conversion device (GPD). The converted particles were directly introduced and measured by ICPMS through a gas exchange device (GED), which could penetrate the particles as well as exchange to Ar from either non-reacted gases such as an air or remaining gases of O3 and NH3. The particle size distribution of converted particles was measured by scanning mobility particle sizer (SMPS) and the results supported the elucidation of particle agglomeration between the particle converted from semiconductor gas and the particle of ammonium nitrate (NH4NO3) which was produced as major particle in GPD. Stable time-resolved signals from AsH3 and PH3 in air were obtained by GPD-GED-ICPMS with continuous gas introduction; however, the slightly larger fluctuation, which could be due to the ionization fluctuation of particles in ICP, was observed compared to that of metal carbonyl gas in Ar introduced directly into ICPMS. The linear regression lines were obtained and the limits of detection (LODs) of 1.5 pL L(-1) and 2.4 nL L(-1) for AsH3 and PH3, respectively, were estimated. Since these LODs revealed sufficiently lower values than the measurement concentrations required from semiconductor industry such as 0.5 nL L(-1) and 30 nL L(-1) for AsH3 and PH3, respectively, the GPD-GED-ICPMS could be useful for direct and high sensitive analysis of ultra-trace semiconductor gas in air. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Online Simultaneous Hydrogen/Deuterium Exchange of Multitarget Gas-Phase Molecules by Electrospray Ionization Mass Spectrometry Coupled with Gas Chromatography.

    Science.gov (United States)

    Jeong, Eun Sook; Cha, Eunju; Cha, Sangwon; Kim, Sunghwan; Oh, Han Bin; Kwon, Oh-Seung; Lee, Jaeick

    2017-11-21

    In this study, a hydrogen/deuterium (H/D) exchange method using gas chromatography-electrospray ionization/mass spectrometry (GC-ESI/MS) was first investigated as a novel tool for online H/D exchange of multitarget analytes. The GC and ESI source were combined with a homemade heated column transfer line. GC-ESI/MS-based H/D exchange occurs in an atmospheric pressure ion source as a result of reacting the gas-phase analyte eluted from GC with charged droplets of deuterium oxide infused as the ESI spray solvent. The consumption of the deuterated solvent at a flow rate of 2 μL min -1 was more economical than that in online H/D exchange methods reported to date. In-ESI-source H/D exchange by GC-ESI/MS was applied to 11 stimulants with secondary amino or hydroxyl groups. After H/D exchange, the spectra of the stimulants showed unexchanged, partially exchanged, and fully exchanged ions showing various degrees of exchange. The relative abundances corrected for naturally occurring isotopes of the fully exchanged ions of stimulants, except for etamivan, were in the range 24.3-85.5%. Methylephedrine and cyclazodone showed low H/D exchange efficiency under acidic, neutral, and basic spray solvent conditions and nonexchange for etamivan with an acidic phenolic OH group. The in-ESI-source H/D exchange efficiency by GC-ESI/MS was sufficient to determine the number of hydrogen by elucidation of fragmentation from the spectrum. Therefore, this online H/D exchange technique using GC-ESI/MS has potential as an alternative method for simultaneous H/D exchange of multitarget analytes.

  10. Numerical analysis of exhaust gas flow during the gas exchange process and the design optimization; Haiki manihorudonai no hiteijo nagare kaiseki gijutsu to sono oyo

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, K; Takeyama, S; Sakai, E; Tanzawa, K [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    A simulation method was developed to estimate exhaust gas flow during the gas exchange process. In this simulation, one dimensional in-cylinder gas flow calculation and three dimensional exhaust gas flow calculation were combined. Gas flow inside the exhaust manifold catalyst during gas exchange was agreed in experiments. A simulation method was applied to select oxygen sensor location. A prediction of the oxygen sensor sensitivity of each cylinder gas was presented. The possibility of selecting oxygen sensor location in the exhaust manifold using calculation was proved. 5 refs., 10 figs., 1 tab.

  11. Influence of heat exchange of reservoir with rocks on hot gas injection via a single well

    Science.gov (United States)

    Nikolaev, Vladimir E.; Ivanov, Gavril I.

    2017-11-01

    In the computational experiment the influence of heat exchange through top and bottom of the gas-bearing reservoir on the dynamics of temperature and pressure fields during hot gas injection via a single well is investigated. The experiment was carried out within the framework of modified mathematical model of non-isothermal real gas filtration, obtained from the energy and mass conservation laws and the Darcy law. The physical and caloric equations of state together with the Newton-Riemann law of heat exchange of gas reservoir with surrounding rocks, are used as closing relations. It is shown that the influence of the heat exchange with environment on temperature field of the gas-bearing reservoir is localized in a narrow zone near its top and bottom, though the size of this zone is increased with time.

  12. Pulmonary hemodynamics and gas exchange in off pump coronary artery bypass grafting.

    Science.gov (United States)

    Vedin, Jenny; Jensen, Ulf; Ericsson, Anders; Samuelsson, Sten; Vaage, Jarle

    2005-10-01

    To investigate the influence of cardiopulmonary bypass on pulmonary hemodynamics and gas exchange. Low risk patients admitted for elective coronary artery bypass grafting were randomized to either on (n=25) or off pump (n=25) surgery. Central hemodynamics, gas exchange, and venous admixture were studied during and up to 20 h after surgery. There was no difference in pulmonary vascular resistance index (P=0.16), right ventricular stroke work index (P>0.2), mean pulmonary artery pressure (P>0.2) or pulmonary capillary wedge pressure (P>0.2) between groups. Soon after surgery there was a tendency towards higher cardiac index (P=0.07) in the off pump group. Arterial oxygen tension (P>0.2), hematocrit (P>0.2), venous admixture (P>0.2), and arterial-venous oxygen content difference (P=0.12) did not differ between groups. This prospective, randomized study showed no difference in pulmonary hemodynamics, pulmonary gas exchange, and venous admixture, in low risk patients undergoing off pump compared to on pump coronary artery bypass surgery.

  13. A computational model of insect discontinuous gas exchange: A two-sensor, control systems approach.

    Science.gov (United States)

    Grieshaber, Beverley J; Terblanche, John S

    2015-06-07

    The insect gas exchange system is characterised by branching air-filled tubes (tracheae/tracheoles) and valve-like structures in their outer integument (spiracles) which allow for a periodic gas exchange pattern known as the discontinuous gas exchange cycle (DGC). The DGC facilitates the temporal decoupling of whole animal gas exchange from cellular respiration rates and may confer several physiological benefits, which are nevertheless highly controversial (primarily reduction of cellular oxidative damage and/or respiratory water saving). The intrinsic and extrinsic factors influencing DGCs are the focus of extensive ongoing research and little consensus has been reached on the evolutionary genesis or mechanistic costs and benefits of the pattern. Despite several hypotheses and much experimental and evolutionary biology research, a mechanistic physical model, which captures various key elements of the DGC pattern, is currently lacking. Here, we present a biologically realistic computational, two-sensor DGC model (pH/carbon dioxide and oxygen setpoints) for an Orthopteran gas exchange system, and show computationally for the first time that a control system of two interacting feedback loops is capable of generating a full DGC pattern with outputs which are physiologically realistic, quantitatively matching experimental results found in this taxonomic model elsewhere. A finite-element mathematical approach is employed and various trigger sets are considered. Parameter sensitivity analyses suggest that various aspects of insect DGC are adequately captured in this model. In particular, with physiologically relevant input parameters, the full DGC pattern is induced; and the phase durations, endotracheal carbon dioxide partial pressure ranges, and pH fluctuations which arise are physically realistic. The model results support the emergent property hypothesis for the existence of DGC, and indicate that asymmetric loading and off-loading (hysteresis) in one of the sensor

  14. Tritium removal by hydrogen isotopic exchange between hydrogen gas and water on hydrophobic catalyst

    International Nuclear Information System (INIS)

    Morishita, T.; Isomura, S.; Izawa, H.; Nakane, R.

    1980-01-01

    Many kinds of the hydrophobic catalysts for hydrogen isotopic exchange between hydrogen gas and water have been prepared. The carriers are the hydrophobic organic materials such as polytetrafluoroethylene(PTFE), monofluorocarbon-PTFE mixture(PTFE-FC), and styrene-divinylbenzene copolymer(SDB). 0.1 to 2 wt % Pt is deposited on the carriers. The Pt/SDB catalyst has much higher activity than the Pt/PTFE catalyst and the Pt/PTFE-FC catalyst shows the intermediate value of catalytic activity. The observation of electron microscope shows that the degrees of dispersion of Pt particles on the hydrophobic carriers result in the difference of catalytic activities. A gas-liquid separated type column containing ten stages is constructed. Each stage is composed of both the hydrophobic catalyst bed for the hydrogen gas/water vapor isotopic exchange and the packed column type bed for the water vapor/liquid water isotopic exchange. In the column hydrogen gas and water flow countercurrently and hydrogen isotopes are separated

  15. Acute effects of temperature and hypercarbia on cutaneous and branchial gas exchange in the South American lungfish, Lepidosiren paradoxa.

    Science.gov (United States)

    Zena, Lucas A; Bícego, Kênia C; da Silva, Glauber S F; Giusti, Humberto; Glass, Mogens L; Sanchez, Adriana P

    2017-01-01

    The South American lungfish, Lepidosiren paradoxa inhabits seasonal environments in the Central Amazon and Paraná-Paraguay basins that undergo significant oscillations in temperature throughout the year. They rely on different gas exchange organs, such as gills and skin for aquatic gas exchange while their truly bilateral lungs are responsible for aerial gas exchange; however, there are no data available on the individual contributions of the skin and the gills to total aquatic gas exchange in L. paradoxa. Thus, in the present study we quantify the relative contributions of skin and gills on total aquatic gas exchange during warm (35°C) and cold exposure (20°C) in addition to the effects of aerial and aquatic hypercarbia on aquatic gas exchange and gill ventilation rate (f G ; 25°C), respectively. Elevated temperature (35°C) caused a significant increase in the contribution of cutaneous (from 0.61±0.13 to 1.34±0.26ml. STPD.h -1 kg -1 ) and branchial (from 0.54±0.17 to 1.73±0.53ml. STPD.h -1 kg -1 ) gas exchange for V̇CO 2 relative to the lower temperature (20°C), while V̇O 2 remained relatively unchanged. L. paradoxa exhibited a greater branchial contribution in relation to total aquatic gas exchange at lower temperatures (20 and 25°C) for oxygen uptake. Aerial hypercarbia decreased branchial V̇O 2 whereas branchial V̇CO 2 was significantly increased. Progressive increases in aquatic hypercarbia did not affect f G . This response is in contrast to increases in pulmonary ventilation that may offset any increase in arterial partial pressure of CO 2 owing to CO 2 loading through the animals' branchial surface. Thus, despite their reduced contribution to total gas exchange, cutaneous and branchial gas exchange in L. paradoxa can be significantly affected by temperature and aerial hypercarbia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Probing the Binding Interfaces of Protein Complexes Using Gas-Phase H/D Exchange Mass Spectrometry

    DEFF Research Database (Denmark)

    Mistarz, Ulrik H; Brown, Jeffery M; Haselmann, Kim F

    2016-01-01

    Fast gas-phase hydrogen/deuterium exchange mediated by ND3 gas and measured by mass spectrometry (gas-phase HDX-MS) is a largely unharnessed, fast, and sensitive method for probing primary- and higher-order polypeptide structure. Labeling of heteroatom-bound non-amide hydrogens in a sub-milliseco......Fast gas-phase hydrogen/deuterium exchange mediated by ND3 gas and measured by mass spectrometry (gas-phase HDX-MS) is a largely unharnessed, fast, and sensitive method for probing primary- and higher-order polypeptide structure. Labeling of heteroatom-bound non-amide hydrogens in a sub......-millisecond time span after electrospray ionization by ND3 gas can provide structural insights into protein conformers present in solution. Here, we have explored the use of gas-phase HDX-MS for probing the higher-order structure and binding interfaces of protein complexes originating from native solution...

  17. Hydraulic and thermal design of a gas microchannel heat exchanger

    International Nuclear Information System (INIS)

    Yang Yahui; Brandner, Juergen J; Morini, Gian Luca

    2012-01-01

    In this paper investigations on the design of a gas flow microchannel heat exchanger are described in terms of hydrodynamic and thermal aspects. The optimal choice for thermal conductivity of the solid material is discussed by analysis of its influences on the thermal performance of a micro heat exchanger. Two numerical models are built by means of a commercial CFD code (Fluent). The simulation results provide the distribution of mass flow rate, inlet pressure and pressure loss, outlet pressure and pressure loss, subjected to various feeding pressure values. Based on the thermal and hydrodynamic analysis, a micro heat exchanger made of polymer (PEEK) is designed and manufactured for flow and heat transfer measurements in air flows. Sensors are integrated into the micro heat exchanger in order to measure the local pressure and temperature in an accurate way. Finally, combined with numerical simulation, an operating range is suggested for the present micro heat exchanger in order to guarantee uniform flow distribution and best thermal and hydraulic performances.

  18. The acute effect of exercise modality and nutrition manipulations on post-exercise resting energy expenditure and respiratory exchange ratio in women: a randomized trial.

    Science.gov (United States)

    Wingfield, Hailee L; Smith-Ryan, Abbie E; Melvin, Malia N; Roelofs, Erica J; Trexler, Eric T; Hackney, Anthony C; Weaver, Mark A; Ryan, Eric D

    2015-12-01

    The purpose of this study was to examine the effect of exercise modality and pre-exercise carbohydrate (CHO) or protein (PRO) ingestion on post-exercise resting energy expenditure (REE) and respiratory exchange ratio (RER) in women. Twenty recreationally active women (mean ± SD; age 24.6 ± 3.9 years; height 164.4 ± 6.6 cm; weight 62.7 ± 6.6 kg) participated in this randomized, crossover, double-blind study. Each participant completed six exercise sessions, consisting of three exercise modalities: aerobic endurance exercise (AEE), high-intensity interval running (HIIT), and high-intensity resistance training (HIRT); and two acute nutritional interventions: CHO and PRO. Salivary samples were collected before each exercise session to determine estradiol-β-17 and before and after to quantify cortisol. Post-exercise REE and RER were analyzed via indirect calorimetry at the following: baseline, immediately post (IP), 30 minutes (30 min) post, and 60 minutes (60 min) post exercise. A mixed effects linear regression model, controlling for estradiol, was used to compare mean longitudinal changes in REE and RER. On average, HIIT produced a greater REE than AEE and HIRT (p HIIT produced lower RER compared to either AEE or HIRT after 30 min (p HIIT resulted in the largest increase in REE and largest reduction in RER.

  19. Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

    Science.gov (United States)

    Kaushik, S Sivaram; Freeman, Matthew S; Cleveland, Zackary I; Davies, John; Stiles, Jane; Virgincar, Rohan S; Robertson, Scott H; He, Mu; Kelly, Kevin T; Foster, W Michael; McAdams, H Page; Driehuys, Bastiaan

    2013-09-01

    Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate "129Xe gas-transfer" maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of -2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm (P exchange caused by differences in lung inflation and posture.

  20. Devise of an exhaust gas heat exchanger for a thermal oil heater in a palm oil refinery plant

    Science.gov (United States)

    Chucherd, Panom; Kittisupakorn, Paisan

    2017-08-01

    This paper presents the devise of an exhaust gas heat exchanger for waste heat recovery of the exhausted flue gas of palm oil refinery plant. This waste heat can be recovered by installing an economizer to heat the feed water which can save the fuel consumption of the coal fired steam boiler and the outlet temperature of flue gas will be controlled in order to avoid the acid dew point temperature and protect the filter bag. The decrease of energy used leads to the reduction of CO2 emission. Two designed economizer studied in this paper are gas in tube and water in tube. The gas in tube exchanger refers to the shell and tube heat exchanger which the flue gas flows in tube; this designed exchanger is used in the existing unit. The new designed water in tube refers to the shell and tube heat exchanger which the water flows in the tube; this designed exchanger is proposed for new implementation. New economizer has the overall coefficient of heat transfer of 19.03 W/m2.K and the surface heat transfer area of 122 m2 in the optimized case. Experimental results show that it is feasible to install economizer in the exhaust flue gas system between the air preheater and the bag filter, which has slightly disadvantage effect in the system. The system can raise the feed water temperature from 40 to 104°C and flow rate 3.31 m3/h, the outlet temperature of flue gas is maintained about 130 °C.

  1. Gas exchange rates across the sediment-water andd air-water interfaces in south San Francisco Bay

    International Nuclear Information System (INIS)

    Hartman, B.; Hammond, D.E.

    1984-01-01

    Radon 222 concentrations in the water and sedimentary columns and radon exchange rates across the sediment-water and air-water interfaces have been measured in a section of south San Francisco Bay. Two independent methods have been used to determine sediment-water exchange rates, and the annual averages of these methods agree within the uncertainity of the determinations, about 20%. The annual average of bethic fluxes from shoal areas is nearly a factor of 2 greater than fluxes from the channel areas. Fluxes from the shoal and channel areas exceed those expected from simple molecular diffusion by factors of 4 and 2, respectively, apparently due to macrofaunal irrigation. Values of the gas transfer coefficient for radon exchange across the air-water inteface were determined by constructing a radon mass balance for the water column and by direct measurement using floating chambers. The chamber method appears to yield results which are too high. Transfer coefficients computed using the mass balance method range from 0.4 m/day to 1.8 m/day, with a 6-year average of 1.0 m/day. Gas exchange is linearly dependent upon wind speed over a wind speed range of 3.2--6.4 m/s, but shows no dependence upon current velocity. Gas transfer coefficients predicted from an empirical relationship between gas exchange rates and wind speed observed in lakes and the oceans are within 30% of the coefficients determined from the radon mass balance and are considerably more accurate than coefficients predicted from theoretical gas exchange models

  2. Gas exchange rates across the sediment-water and air-water interfaces in south San Francisco Bay

    Science.gov (United States)

    Hartman, Blayne; Hammond, Douglas E.

    1984-01-01

    Radon 222 concentrations in the water and sedimentary columns and radon exchange rates across the sediment-water and air-water interfaces have been measured in a section of south San Francisco Bay. Two independent methods have been used to determine sediment-water exchange rates, and the annual averages of these methods agree within the uncertainty of the determinations, about 20%. The annual average of benthic fluxes from shoal areas is nearly a factor of 2 greater than fluxes from the channel areas. Fluxes from the shoal and channel areas exceed those expected from simple molecular diffusion by factors of 4 and 2, respectively, apparently due to macrofaunal irrigation. Values of the gas transfer coefficient for radon exchange across the air-water interface were determined by constructing a radon mass balance for the water column and by direct measurement using floating chambers. The chamber method appears to yield results which are too high. Transfer coefficients computed using the mass balance method range from 0.4 m/day to 1.8 m/day, with a 6-year average of 1.0 m/day. Gas exchange is linearly dependent upon wind speed over a wind speed range of 3.2–6.4 m/s, but shows no dependence upon current velocity. Gas transfer coefficients predicted from an empirical relationship between gas exchange rates and wind speed observed in lakes and the oceans are within 30% of the coefficients determined from the radon mass balance and are considerably more accurate than coefficients predicted from theoretical gas exchange models.

  3. Test results from a helium gas-cooled porous metal heat exchanger

    International Nuclear Information System (INIS)

    North, M.T.; Rosenfeld, J.H.; Youchison, D.L.

    1996-01-01

    A helium-cooled porous metal heat exchanger was built and tested, which successfully absorbed heat fluxes exceeding all previously tested gas-cooled designs. Helium-cooled plasma-facing components are being evaluated for fusion applications. Helium is a favorable coolant for fusion devices because it is not a plasma contaminant, it is not easily activated, and it is easily removed from the device in the event of a leak. The main drawback of gas coolants is their relatively poor thermal transport properties. This limitation can be removed through use of a highly efficient heat exchanger design. A low flow resistance porous metal heat exchanger design was developed, based on the requirements for the Faraday shield for the International Thermonuclear Experimental Reactor (ITER) device. High heat flux tests were conducted on two representative test articles at the Plasma Materials Test Facility (PMTF) at Sandia National Laboratories. Absorbed heat fluxes as high as 40 MW/m 2 were successfully removed during these tests without failure of the devices. Commercial applications for electronics cooling and other high heat flux applications are being identified

  4. Gas Exchange and Mechanical Properties of the Lung in Miners with Severe Concomitant Injury

    Directory of Open Access Journals (Sweden)

    V. V. Moroz

    2007-01-01

    Full Text Available Objective: to study the specific features of pulmonary gas exchange and mechanical properties in various manifestations of respiratory failure in miners with severe concomitant injury, who have a service length of 10 years or more, in order to optimize respiratory support.Subjects and methods. Pulmonary gas exchange and mechanical properties were studied over time in the presence of respiratory failure (acute lung injury/acute respiratory distress syndrome in 34 miners and 36 victims (a control group with severe concomitant injury who had no underground service length. Both groups were matched in age, severity and nature of traumatic lesions and surgical interventions. Pulmonary gas exchange and mechanical properties were evaluated by the following indices: oxygen fraction in an inspired gas mixture; hemoglobin saturation and partial arterial blood oxygen and carbon dioxide tension with the alveolar-arterial gradient being calculated by the oxygen level; oxygenation index; intrapulmonary shunting; statistical compliance and airways resistance.Results. The studies demonstrated that the miners, as compared with the controls, had more pronounced gas exchange changes within 5—7 post-traumatic days; later on (days 7—9 the above differences were undetectable. Impaired pulmonary mechanical properties in the miners persisted throughout the study while in the control group, their recovery started just on day 3. The course of respiratory failure in the miners was attributable to the baseline external respiratory function. Their respiratory support was performed during 14.5±1.4 days versus 9.5±1.9 days in the controls. In the miners, the mean bed-days at an intensive care unit were 18.5±2.2 whereas in the controls those were 12.3±2.1.Conclusion. More significant impairments of pulmonary gas exchange and mechanical properties are seen in the miners due to the background changes in external respiratory function in the development of respiratory

  5. Gas exchange under water. Acclimation of terrestrial plants to submergence

    NARCIS (Netherlands)

    Mommer, L.

    2005-01-01

    Gas exchange between the plant and the environment is severely hampered when plants are submerged, leading to oxygen and energy deficits. A straightforward way to reduce these shortages of oxygen and carbohydrates would be prolonged photosynthesis under water, but this has received only little

  6. Heat exchanger design considerations for high temperature gas-cooled reactor (HTGR) plants

    International Nuclear Information System (INIS)

    McDonald, C.F.; Vrable, D.L.; Van Hagan, T.H.; King, J.H.; Spring, A.H.

    1980-02-01

    Various aspects of the high-temperature heat exchanger conceptual designs for the gas turbine (HTGR-GT) and process heat (HTGR-PH) plants are discussed. Topics include technology background, heat exchanger types, surface geometry, thermal sizing, performance, material selection, mechanical design, fabrication, and the systems-related impact of installation and integration of the units in the prestressed concrete reactor vessel. The impact of future technology developments, such as the utilization of nonmetallic materials and advanced heat exchanger surface geometries and methods of construction, is also discussed

  7. Regulation and acclimation of leaf gas exchange in a piñon-juniper woodland exposed to three different precipitation regimes.

    Science.gov (United States)

    Limousin, Jean-Marc; Bickford, Christopher P; Dickman, Lee T; Pangle, Robert E; Hudson, Patrick J; Boutz, Amanda L; Gehres, Nathan; Osuna, Jessica L; Pockman, William T; McDowell, Nate G

    2013-10-01

    Leaf gas-exchange regulation plays a central role in the ability of trees to survive drought, but forecasting the future response of gas exchange to prolonged drought is hampered by our lack of knowledge regarding potential acclimation. To investigate whether leaf gas-exchange rates and sensitivity to drought acclimate to precipitation regimes, we measured the seasonal variations of leaf gas exchange in a mature piñon-juniper Pinus edulis-Juniperus monosperma woodland after 3 years of precipitation manipulation. We compared trees receiving ambient precipitation with those in an irrigated treatment (+30% of ambient precipitation) and a partial rainfall exclusion (-45%). Treatments significantly affected leaf water potential, stomatal conductance and photosynthesis for both isohydric piñon and anisohydric juniper. Leaf gas exchange acclimated to the precipitation regimes in both species. Maximum gas-exchange rates under well-watered conditions, leaf-specific hydraulic conductance and leaf water potential at zero photosynthetic assimilation all decreased with decreasing precipitation. Despite their distinct drought resistance and stomatal regulation strategies, both species experienced hydraulic limitation on leaf gas exchange when precipitation decreased, leading to an intraspecific trade-off between maximum photosynthetic assimilation and resistance of photosynthesis to drought. This response will be most detrimental to the carbon balance of piñon under predicted increases in aridity in the southwestern USA. © 2013 John Wiley & Sons Ltd.

  8. An optioneering and concept design study for the Astrid sodium-gas heat exchanger matrix

    International Nuclear Information System (INIS)

    Hattrell, T.; Lopez-Ramirez, S.; Pilatis, N.

    2014-01-01

    The ASTRID generation IV sodium cooled fast reactor design being developed by the CEA requires a component to transfer heat from the core to the power cycle. One of the ASTRID configurations currently being developed by the CEA uses a sodium to gas heat exchanger (SGHE) to fulfil this function. The design of the SGHE is challenging because of the high temperature of the sodium coolant and the significant pressure differential between the sodium and gas sides of the heat exchanger. This paper presents a study of the options examined for the ASTRID SGHE. A compact, superplastic formed diffusion bonded (SPF-DB) heat exchanger matrix (e.g. SGHE core) is proposed, based on the aerospace technology used by Rolls-Royce to manufacture light and strong wide chord fan blades for gas turbines. The in-house code CHESS is used to examine a number of feasible configurations for the matrix of the heat exchanger component and an optimisation study to maximise the thermal and mechanical performance of the most promising configurations is reported. The optimal matrix geometry identified by the study has a power density for the heat transfer region 157%1 greater than the baseline geometry (authors)

  9. Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange.

    Science.gov (United States)

    Matharoo, Harpreet; Dabaghi, Mohammadhossein; Rochow, Niels; Fusch, Gerhard; Saraei, Neda; Tauhiduzzaman, Mohammed; Veldhuis, Stephen; Brash, John; Fusch, Christoph; Selvaganapathy, P Ravi

    2018-01-01

    Respiratory distress syndrome (RDS) is one of the main causes of fatality in newborn infants, particularly in neonates with low birth-weight. Commercial extracorporeal oxygenators have been used for low-birth-weight neonates in neonatal intensive care units. However, these oxygenators require high blood volumes to prime. In the last decade, microfluidics oxygenators using enriched oxygen have been developed for this purpose. Some of these oxygenators use thin polydimethylsiloxane (PDMS) membranes to facilitate gas exchange between the blood flowing in the microchannels and the ambient air outside. However, PDMS is elastic and the thin membranes exhibit significant deformation and delamination under pressure which alters the architecture of the devices causing poor oxygenation or device failure. Therefore, an alternate membrane with high stability, low deformation under pressure, and high gas exchange was desired. In this paper, we present a novel composite membrane consisting of an ultra-thin stainless-steel mesh embedded in PDMS, designed specifically for a microfluidic single oxygenator unit (SOU). In comparison to homogeneous PDMS membranes, this composite membrane demonstrated high stability, low deformation under pressure, and high gas exchange. In addition, a new design for oxygenator with sloping profile and tapered inlet configuration has been introduced to achieve the same gas exchange at lower pressure drops. SOUs were tested by bovine blood to evaluate gas exchange properties. Among all tested SOUs, the flat design SOU with composite membrane has the highest oxygen exchange of 40.32 ml/min m 2 . The superior performance of the new device with composite membrane was demonstrated by constructing a lung assist device (LAD) with a low priming volume of 10 ml. The LAD was achieved by the oxygen uptake of 0.48-0.90 ml/min and the CO 2 release of 1.05-2.27 ml/min at blood flow rates ranging between 8 and 48 ml/min. This LAD was shown to increase the

  10. Study of regional pulmonary gas exchange using radiotracers

    International Nuclear Information System (INIS)

    Hichwa, R.D.

    1981-01-01

    Respiration involves the exchange of gases between the environment and the blood across the alveolar membrane. Four processes characterize the dynamics of gas exchange: ventilation, diffusion, perfusion and chemical binding with hemoglobin. A study was undertaken to investigate each of these processes, utilizing accelerator production and high yield synthesis of four gaseous radiotracers (/sup 81m/Kr, Ch 3 18 F, 11 CO, 15 O 2 ). Conventional gamma camera images and ancillary physiological data were acquired. Mathematical models were developed to predict the tracer clearance from the lungs during a breath hold and during washout post breath hold. Images of the insoluble /sup 81m/Kr synchronized with the tidal breathing maneuver depict regional ventilation. Tracer bolus inhalation, relative compliance and regional phase information are obtained from krypton dCynamic studies. More soluble CH 3 18 F is used to determine regional pulmonary perfusion during a breath hold. Respiratory clearance of seven, inert, positron-emitting radiotracers define the tracer volume of distribution. The tight-binding of 11 CO to hemoglobin permits the regional measurement of carbon monoxide pulmonary diffusion capacity. A relative CO blood:gas partition coefficient is calculated from the washout of no-carrier-added levels of 11 CO and verified by in vitro radiometric measurements. Regional oxygen pulmonary diffusion capacity determined from 15 O 2 clearance during a breath hold reveals results similar to those obtained with CO. All experimental data are in good agreement with the predictions of a two-compartment open model. A more advanced oxygen model is presented that incorporates radioactive oxygen exchange with stable oxygen on the hemoglobin molecule and metabolic removal of the tracer at the tissues

  11. Air-water gas exchange and CO2 flux in a mangrove-dominated estuary

    Science.gov (United States)

    Ho, David T.; Ferrón, Sara; Engel, Victor C.; Larsen, Laurel G.; Barr, Jordan G.

    2014-01-01

    Mangrove forests are highly productive ecosystems, but the fate of mangrove-derived carbon remains uncertain. Part of that uncertainty stems from the fact that gas transfer velocities in mangrove-surrounded waters are not well determined, leading to uncertainty in air-water CO2 fluxes. Two SF6 tracer release experiments were conducted to determine gas transfer velocities (k(600) = 8.3 ± 0.4 and 8.1 ± 0.6 cm h−1), along with simultaneous measurements of pCO2 to determine the air-water CO2 fluxes from Shark River, Florida (232.11 ± 23.69 and 171.13 ± 20.28 mmol C m−2 d−1), an estuary within the largest contiguous mangrove forest in North America. The gas transfer velocity results are consistent with turbulent kinetic energy dissipation measurements, indicating a higher rate of turbulence and gas exchange than predicted by commonly used wind speed/gas exchange parameterizations. The results have important implications for carbon fluxes in mangrove ecosystems.

  12. Low light availability affects leaf gas exchange, growth and survival ...

    African Journals Online (AJOL)

    The values of dark respiration rate (Rd) and photosynthetic compensation irradiance (Ic) were sufficiently low for a positive carbon balance. Notwithstanding, the interpretation of results of microclimate variables together with leaf gas exchange and growth variables indicated that seedlings at all sites were in a suboptimal ...

  13. The Effect of Rain on Air-Water Gas Exchange

    Science.gov (United States)

    Ho, David T.; Bliven, Larry F.; Wanninkhof, Rik; Schlosser, Peter

    1997-01-01

    The relationship between gas transfer velocity and rain rate was investigated at NASA's Rain-Sea Interaction Facility (RSIF) using several SF, evasion experiments. During each experiment, a water tank below the rain simulator was supersaturated with SF6, a synthetic gas, and the gas transfer velocities were calculated from the measured decrease in SF6 concentration with time. The results from experiments with IS different rain rates (7 to 10 mm/h) and 1 of 2 drop sizes (2.8 or 4.2 mm diameter) confirm a significant and systematic enhancement of air-water gas exchange by rainfall. The gas transfer velocities derived from our experiment were related to the kinetic energy flux calculated from the rain rate and drop size. The relationship obtained for mono-dropsize rain at the RSIF was extrapolated to natural rain using the kinetic energy flux of natural rain calculated from the Marshall-Palmer raindrop size distribution. Results of laboratory experiments at RSIF were compared to field observations made during a tropical rainstorm in Miami, Florida and show good agreement between laboratory and field data.

  14. Heat exchanger for transfering heat produced in a high temperature reactor to an intermediate circuit gas

    International Nuclear Information System (INIS)

    Barchewitz, E.; Baumgaertner, H.

    1985-01-01

    The invention is concerned with improving the arrangement of a heat exchanger designed to transfer heat from the coolant gas circuit of a high temperature reactor to a gas which is to be used for a process heat plant. In the plant the material stresses are to be kept low at high differential pressures and temperatures. According to the invention the tube bundles designed as boxes are fixed within the heat exchanger closure by means of supply pipes having got loops. For conducting the hot gas the heat exchanger has got a central pipe leading out of the reactor vessel through the pod closure and having got only one point of fixation, lying in this closure. Additional advantageous designs are mentioned. (orig./PW)

  15. Radiation from Large Gas Volumes and Heat Exchange in Steam Boiler Furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, A. N., E-mail: tgtu-kafedra-ese@mail.ru [Tver State Technical University (Russian Federation)

    2015-09-15

    Radiation from large cylindrical gas volumes is studied as a means of simulating the flare in steam boiler furnaces. Calculations of heat exchange in a furnace by the zonal method and by simulation of the flare with cylindrical gas volumes are described. The latter method is more accurate and yields more reliable information on heat transfer processes taking place in furnaces.

  16. Single Sodium Pyruvate Ingestion Modifies Blood Acid-Base Status and Post-Exercise Lactate Concentration in Humans

    Directory of Open Access Journals (Sweden)

    Robert A. Olek

    2014-05-01

    Full Text Available This study examined the effect of a single sodium pyruvate ingestion on a blood acid-base status and exercise metabolism markers. Nine active, but non-specifically trained, male subjects participated in the double-blind, placebo-controlled, crossover study. One hour prior to the exercise, subjects ingested either 0.1 g·kg−1 of body mass of a sodium pyruvate or placebo. The capillary blood samples were obtained at rest, 60 min after ingestion, and then three and 15 min after completing the workout protocol to analyze acid-base status and lactate, pyruvate, alanine, glucose concentrations. The pulmonary gas exchange, minute ventilation and the heart rate were measured during the exercise at a constant power output, corresponding to ~90% O2max. The blood pH, bicarbonate and the base excess were significantly higher after sodium pyruvate ingestion than in the placebo trial. The blood lactate concentration was not different after the ingestion, but the post-exercise was significantly higher in the pyruvate trial (12.9 ± 0.9 mM than in the placebo trial (10.6 ± 0.3 mM, p < 0.05 and remained elevated (nonsignificant after 15 min of recovery. The blood pyruvate, alanine and glucose concentrations, as well as the overall pulmonary gas exchange during the exercise were not affected by the pyruvate ingestion. In conclusion, the sodium pyruvate ingestion one hour before workout modified the blood acid-base status and the lactate production during the exercise.

  17. Diurnal Variation in Gas Exchange: The Balance between Carbon Fixation and Water Loss.

    Science.gov (United States)

    Matthews, Jack S A; Vialet-Chabrand, Silvere R M; Lawson, Tracy

    2017-06-01

    Stomatal control of transpiration is critical for maintaining important processes, such as plant water status, leaf temperature, as well as permitting sufficient CO 2 diffusion into the leaf to maintain photosynthetic rates ( A ). Stomatal conductance often closely correlates with A and is thought to control the balance between water loss and carbon gain. It has been suggested that a mesophyll-driven signal coordinates A and stomatal conductance responses to maintain this relationship; however, the signal has yet to be fully elucidated. Despite this correlation under stable environmental conditions, the responses of both parameters vary spatially and temporally and are dependent on species, environment, and plant water status. Most current models neglect these aspects of gas exchange, although it is clear that they play a vital role in the balance of carbon fixation and water loss. Future efforts should consider the dynamic nature of whole-plant gas exchange and how it represents much more than the sum of its individual leaf-level components, and they should take into consideration the long-term effect on gas exchange over time. © 2017 American Society of Plant Biologists. All Rights Reserved.

  18. Application of metal foam heat exchangers for a high-performance liquefied natural gas regasification system

    International Nuclear Information System (INIS)

    Kim, Dae Yeon; Sung, Tae Hong; Kim, Kyung Chun

    2016-01-01

    The intermediate fluid vaporizer has wide applications in the regasification of LNG (liquefied natural gas). The heat exchanger performance is one of the main contributors to the thermodynamic and cost effectiveness of the entire LNG regasification system. Within the paper, the authors discuss a new concept for a compact heat exchanger with a micro-cellular structure medium to minimize volume and mass and to increase thermal efficiency. Numerical calculations have been conducted to design a metal-foam filled plate heat exchanger and a shell-and-tube heat exchanger using published experimental correlations. The geometry of both heat exchangers was optimized using the conditions of thermolators in LNG regasification systems. The heat transfer and pressure drop performance was predicted to compare the heat exchangers. The results show that the metal-foam plate heat exchanger has the best performance at different channel heights and mass flow rates of fluid. In the optimized configurations, the metal-foam plate heat exchanger has a higher heat transfer rate and lower pressure drop than the shell-and-tube heat exchanger as the mass flow rate of natural gas is increased. - Highlights: • A metal foam heat exchanger is proposed for LNG regasification system. • Comparison was made with a shell and tube heat exchanger. • Heat transfer and pressure drop characteristics were estimated. • The geometry of both heat exchangers is optimized for thermolators. • It can be used as a compact and high performance thermolators.

  19. Catalytic isotope exchange reaction between deuterium gas and water pre-adsorbed on platinum/alumina

    International Nuclear Information System (INIS)

    Iida, Itsuo; Kato, Junko; Tamaru, Kenzi.

    1976-01-01

    The catalytic isotope exchange reaction between deuterium gas and the water pre-adsorbed on Pt/Al 2 O 3 was studied. At reaction temperatures above 273 K, the exchange rate was proportional to the deuterium pressure and independent of the amount of adsorbed water, which suggests that the rate determining step is the supply of deuterium from the gas phase. Its apparent activation energy was 38 kJ mol -1 . Below freezing point of water, the kinetic behaviour was different from that above freezing point. At higher deuterium pressures the rate dropped abruptly at 273 K. Below the temperature the apparent activation energy was 54 kJ mol -1 and the exchange rate depended not on the deuterium pressure but on the amount of the pre-adsorbed water. At lower pressures, however, the kinetic behaviour was the same as the above 273 K, till the rate of the supply of deuterium from the gas phase exceeded the supply of hydrogen from adsorbed water to platinum surface. These results suggest that below 273 K the supply of hydrogen is markedly retarded, the state of the adsorbed water differing from that above 273 K. It was also demonstrated that when the adsorbed water is in the state of capillary condensation, the exchange rate becomes very small. (auth.)

  20. Effects of flow rate and temperature on cyclic gas exchange in tsetse flies (Diptera, Glossinidae).

    Science.gov (United States)

    Terblanche, John S; Chown, Steven L

    2010-05-01

    Air flow rates may confound the investigation and classification of insect gas exchange patterns. Here we report the effects of flow rates (50, 100, 200, 400 ml min(-1)) on gas exchange patterns in wild-caught Glossina morsitans morsitans from Zambia. At rest, G. m. morsitans generally showed continuous or cyclic gas exchange (CGE) but no evidence of discontinuous gas exchange (DGE). Flow rates had little influence on the ability to detect CGE in tsetse, at least in the present experimental setup and under these laboratory conditions. Importantly, faster flow rates resulted in similar gas exchange patterns to those identified at lower flower rates suggesting that G. m. morsitans did not show DGE which had been incorrectly identified as CGE at lower flow rates. While CGE cycle frequency was significantly different among the four flow rates (prate treatment variation. Using a laboratory colony of closely related, similar-sized G. morsitans centralis we subsequently investigated the effects of temperature, gender and feeding status on CGE pattern variation since these factors can influence insect metabolic rates. At 100 ml min(-1) CGE was typical of G. m. centralis at rest, although it was significantly more common in females than in males (57% vs. 43% of 14 individuals tested per gender). In either sex, temperature (20, 24, 28 and 32 degrees C) had little influence on the number of individuals showing CGE. However, increases in metabolic rate with temperature were modulated largely by increases in burst volume and cycle frequency. This is unusual among insects showing CGE or DGE patterns because increases in metabolic rate are usually modulated by increases in frequency, but either no change or a decline in burst volume. Copyright 2009 Elsevier Ltd. All rights reserved.

  1. Effect of wind and currents on gas exchange in an estuarine system. Final technical report, 1 August 1986-31 July 1987

    International Nuclear Information System (INIS)

    Broecker, W.S.; Ledwell, J.R.; Bopp, R.

    1987-11-01

    The objectives were to develop a non-volatile tracer to use in gas exchange experiments in laterally unconfined systems and to study applications of deliberate tracers in limnology and oceanography. Progress was made on both fronts but work on the development of the non-volatile tracer proved to be more difficult and labor intensive that anticipated so no field experiments using non-volatile tracers was performed as yet. In the search for a suitable non-volatile tracer for an ocean scale gas exchange experiment a tracer was discovered which does not have the required sensitivity for a large scale experiment, but is very easy to analyze and will be well suited for smaller experiments such as gas exchange determinations on rivers and streams. Sulfur hexafluoride, SF 6 , was used successfully as a volatile tracer along with tritium as a non-volatile tracer to study gas exchange rates from a primary stream. This is the first gas exchange experiment in which gas exchange rates were determined on a head water stream where significant groundwater input occurs along the reach. In conjunction with SF 6 , Radon-222 measurements were performed on the groundwater and in the stream. The feasibility of using a combination of SF 6 and radon is being studied to determine groundwater inputs and gas exchange of rates in streams with significant groundwater input without using a non-volatile tracer

  2. Stomatal kinetics and photosynthetic gas exchange along a continuum of isohydric to anisohydric regulation of plant water status.

    Science.gov (United States)

    Meinzer, Frederick C; Smith, Duncan D; Woodruff, David R; Marias, Danielle E; McCulloh, Katherine A; Howard, Ava R; Magedman, Alicia L

    2017-08-01

    Species' differences in the stringency of stomatal control of plant water potential represent a continuum of isohydric to anisohydric behaviours. However, little is known about how quasi-steady-state stomatal regulation of water potential may relate to dynamic behaviour of stomata and photosynthetic gas exchange in species operating at different positions along this continuum. Here, we evaluated kinetics of light-induced stomatal opening, activation of photosynthesis and features of quasi-steady-state photosynthetic gas exchange in 10 woody species selected to represent different degrees of anisohydry. Based on a previously developed proxy for the degree of anisohydry, species' leaf water potentials at turgor loss, we found consistent trends in photosynthetic gas exchange traits across a spectrum of isohydry to anisohydry. More anisohydric species had faster kinetics of stomatal opening and activation of photosynthesis, and these kinetics were closely coordinated within species. Quasi-steady-state stomatal conductance and measures of photosynthetic capacity and performance were also greater in more anisohydric species. Intrinsic water-use efficiency estimated from leaf gas exchange and stable carbon isotope ratios was lowest in the most anisohydric species. In comparisons between gas exchange traits, species rankings were highly consistent, leading to species-independent scaling relationships over the range of isohydry to anisohydry observed. © 2017 John Wiley & Sons Ltd.

  3. Apneic oxygenation combined with extracorporeal arteriovenous carbon dioxide removal provides sufficient gas exchange in experimental lung injury

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Kjærgaard, Benedict; Koefoed-Nielsen, Jacob

    2008-01-01

    We hypothesized that apneic oxygenation, using an open lung approach, combined with extracorporeal CO2 removal, would provide adequate gas exchange in acute lung injury. We tested this hypothesis in nine anesthetized and mechanically ventilated pigs (85-95 kg), in which surfactant was depleted fr....../min. Thus, the method provided adequate gas exchange in this experimental model, suggesting that it might have potential as an alternative treatment modality in acute lung injury.......We hypothesized that apneic oxygenation, using an open lung approach, combined with extracorporeal CO2 removal, would provide adequate gas exchange in acute lung injury. We tested this hypothesis in nine anesthetized and mechanically ventilated pigs (85-95 kg), in which surfactant was depleted from...

  4. BOREAS TE-11 Leaf Gas Exchange Measurements

    Science.gov (United States)

    Hall, Forrest G. (Editor); Papagno, Andrea (Editor); Saugier, Bernard; Pontailler, J. Y.

    2000-01-01

    The Boreal Ecosystem-Atmospheric Study (BOREAS) TE-11 (Terrestrial Ecology) team collected several data sets in support of its efforts to characterize and interpret information on the sap flow, gas exchange, and lichen photosynthesis of boreal vegetation and meteorological data of the area studied. This data set contains measurements of assimilation and transpiration conducted at the Old Jack Pine (OJP) site during the growing seasons of 1993 and 1994. The data are stored in ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

  5. The influence of gas-to-particle conversion on measurements of ammonia exchange over forest

    NARCIS (Netherlands)

    Oss, R. van; Duyzer, J.; Wyers, P.

    1998-01-01

    Measurements of vertical gradients of ammonium nitrate aerosol and NH3 are used together with HNO3 concentrations to study the influence of gas-to-particle conversion (gtpc) on surface exchange processes above a forest. A numerical model of surface exchange, in which a description of gtpc was

  6. Gas exchange of four woody species under salinity and soil waterlogging

    Directory of Open Access Journals (Sweden)

    Alan D. Lima

    Full Text Available ABSTRACT The objective of this study was to evaluate gas exchanges in seedlings of forest species grown in saline soils and subjected to soil waterlogging cycles. The experimental design was completely randomized in a factorial arrangement, with four forest species: Myracrodruon urundeuva Fr Allemão, Mimosa caesalpiniifolia Benth, Tabebuia impetiginosa (Mart. ex. DC. Standl and Azadirachta indica A. Juss, two soil salinity levels (1.2 and 8.6 dS m-1 and two water regimes (with and without waterlogging. Measurements of stomatal conductance, transpiration and CO2 assimilation rate were performed before and after each waterlogging period. The interaction of the highest saline level (8.6 dS m-1 and waterlogging caused greater reductions in leaf gas exchange, except for Mimosa caesalpiniifolia Benth. Tabebuia impetiginosa (Mart. ex. DC. Standl was the species with highest sensitivity to both studied factors of stress.

  7. Impaired cardiopulmonary exercise capacity in patients with hyperthyroidism.

    Science.gov (United States)

    Kahaly, G; Hellermann, J; Mohr-Kahaly, S; Treese, N

    1996-01-01

    Hyperthyroidism (H) has been implicated as a primary cause of decreased exercise tolerance. To our knowledge, analysis of respiratory gas exchange, an efficient noninvasive method in evaluating cardiopulmonary capacity, has not been performed in patients with H. Using cardiopulmonary exercise testing, 12 consecutive women with Graves' H were examined and controlled in euthyroidism (E). Eighteen women with E, in whom cardiac catheterization had ruled out heart disease, served as control subjects (C). The ventilatory anaerobic threshold was determined by means of the V-slope method. Ergometry was performed with patients in a semisupine position using a continuous ramp protocol of 20 W/min. Echocardiography at rest was performed in all patients. In patients with H, heart rate at rest was higher than in patients with E (p lower increase between rest and anaerobic threshold compared with E patients (p = 0.007) and C (p = 0.009). Work rate was reduced (H, 50% vs E, 70%; p = 0.038). In H patients, the anaerobic threshold occurred at 59.6% of maximal oxygen uptake and 72% in E patients, respectively (p = 0.024). In H patients, the linear regression of the heart rate to oxygen uptake ratio showed a reduced slope in comparison with E patients (p = 0.001) and C (p = 0.004). In patients with H, a reduced tidal volume (p = 0.021) and an increased respiratory rate (p = 0.003) in comparison to patients with E were demonstrated. Echocardiographically, H patients had an increased ejection fraction (p = 0.008) and a higher cardiac index (p = 0.008) in comparison with E patients. Analysis of respiratory gas exchange showed marked alterations of cardiopulmonary exercise capacity in H patients, which are reversible in E patients. The impaired chronotropic response during exercise might be the primary limiting factor of reduced work capacity in patients with H.

  8. Leaf gas exchange and yield of three upland rice cultivars

    Directory of Open Access Journals (Sweden)

    Rita de Cássia Félix Alvarez

    2015-03-01

    Full Text Available Studies of physiological parameters associated with crop performance and growth in different groups of upland rice (Oryza sativa L. may support plant breeding programs. We evaluated the role of gas exchange rates and dry matter accumulation (DMA as traits responsible for yields in a traditional (cv. ‘Caiapó’, intermediate (cv. ‘Primavera’ and modern (cv. ‘Maravilha’ upland rice cultivars. Leaf gas exchange rates, DMA, leaf area index (LAI, harvest indexes (HI and yield components were measured on these genotypes in the field, under sprinkler irrigation. Panicles per m2 and DMA at flowering (FL and heading, as well as CO2 assimilation rates (A were similar across these cultivars. The highest yield was found in ‘Primavera’, which may be explained by (i a two-fold higher HI compared to the other cultivars, (ii greater rates of DMA during spikelet formation and grain-filling, as well as (iii a slow natural decrease of A in this cultivar, at the end of the season (between FL and maturation.

  9. A quantitative approach to developing more mechanistic gas exchange models for field grown potato

    DEFF Research Database (Denmark)

    Ahmadi, Seyed Hamid; Andersen, Mathias Neumann; Poulsen, Rolf Thostrup

    2009-01-01

    In this study we introduce new gas exchange models that are developed under natural conditions of field grown potato. The new models could explain about 85% of the stomatal conductance variations, which was much higher than the well-known gas exchange models such as the Ball-Berry model [Ball...... of chemical and hydraulic signalling on stomatal conductance as exp(-β[ABA])exp(-δ|ψ|) in which [ABA] and |ψ| are xylem ABA concentration and absolute value of leaf or stem water potential. In this study we found that stem water potential could be a very reliable indicator of how plant water status affects...

  10. Impact of Detoxification Techniques on Pulmonary Gas Exchange Function in Patients with Generalized Peritonitis

    Directory of Open Access Journals (Sweden)

    R. A. Mlinnik

    2012-01-01

    Full Text Available Objective: to analyze the impact of different detoxification techniques on pulmonary gas exchange function in patients with generalized peritonitis complicated by multiple organ failure. Subjects and methods. One hundred and thirty patients with generalized peritonitis were examined. According to the used detoxification techniques, the patients were divided into 5 groups. All the patients underwent a comprehensive examination, the key element of which was the evaluation of gas exchange parameters. Results. Membrane plasmapheresis and plasmapheresis with sodium hypochlorite infusion to the plasma filter in patients with peritonitis are shown to improve pulmonary blood oxygenation.

  11. Tradeoffs between metabolic rate and spiracular conductance in discontinuous gas exchange of Samia cynthia (Lepidoptera, Saturniidae).

    Science.gov (United States)

    Moerbitz, Christian; Hetz, Stefan K

    2010-05-01

    The insect tracheal system is a unique respiratory system, designed for maximum oxygen delivery at high metabolic demands, e.g. during activity and at high ambient temperatures. Therefore, large safety margins are required for tracheal and spiracular conductance. Spiracles are the entry to the tracheal system and play an important role in controlling discontinuous gas exchange (DGC) between tracheal system and atmosphere in moth pupae. We investigated the effect of modulated metabolic rate (by changing ambient temperature) and modulated spiracular conductance (by blocking all except one spiracles) on gas exchange patterns in Samia pupae. Both, spiracle blocking and metabolic rates, affected respiratory behavior in Samia cynthia pupae. While animals showed discontinuous gas exchange cycles at lower temperatures with unblocked spiracles, the respiratory patterns were cyclic at higher temperatures, with partly blocked spiracles or a combination of these two factors. The threshold for the transition from a discontinuous (DGC) to a cyclic gas exchange ((cyc)GE) was significantly higher in animals with unblocked spiracles (18.7 nmol g(-1) min(-1) vs. 7.9 nmol g(-1) min(-1)). These findings indicate an important influence of spiracle conductance on the DGC, which may occur mostly in insects showing high spiracular conductances and low metabolic rates. Copyright 2009 Elsevier Ltd. All rights reserved.

  12. Measuring gas temperature during spin-exchange optical pumping process

    Science.gov (United States)

    Normand, E.; Jiang, C. Y.; Brown, D. R.; Robertson, L.; Crow, L.; Tong, X.

    2016-04-01

    The gas temperature inside a Spin-Exchange Optical Pumping (SEOP) laser-pumping polarized 3He cell has long been a mystery. Different experimental methods were employed to measure this temperature but all were based on either modelling or indirect measurement. To date there has not been any direct experimental measurement of this quantity. Here we present the first direct measurement using neutron transmission to accurately determine the number density of 3He, the temperature is obtained using the ideal gas law. Our result showed a surprisingly high gas temperature of 380°C, compared to the 245°C of the 3He cell wall temperature and 178°C of the optical pumping oven temperature. This experiment result may be used to further investigate the unsolved puzzle of the "X-factor" in the SEOP process which places an upper bound to the 3He polarization that can be achieved. Additional spin relaxation mechanisms might exist due to the high gas temperature, which could explain the origin of the X-factor.

  13. PREDICTION OF TOTAL DISSOLVED GAS EXCHANGE AT HYDROPOWER DAMS

    Energy Technology Data Exchange (ETDEWEB)

    Hadjerioua, Boualem [ORNL; Pasha, MD Fayzul K [ORNL; Stewart, Kevin M [ORNL; Bender, Merlynn [Bureau of Reclamation; Schneider, Michael L. [U.S. Army Corps of Engineers

    2012-07-01

    Total dissolved gas (TDG) supersaturation in waters released at hydropower dams can cause gas bubble trauma in fisheries resulting in physical injuries and eyeball protrusion that can lead to mortality. Elevated TDG pressures in hydropower releases are generally caused by the entrainment of air in spillway releases and the subsequent exchange of atmospheric gasses into solution during passage through the stilling basin. The network of dams throughout the Columbia River Basin (CRB) are managed for irrigation, hydropower production, flood control, navigation, and fish passage that frequently result in both voluntary and involuntary spillway releases. These dam operations are constrained by state and federal water quality standards for TDG saturation which balance the benefits of spillway operations designed for Endangered Species Act (ESA)-listed fisheries versus the degradation to water quality as defined by TDG saturation. In the 1970s, the United States Environmental Protection Agency (USEPA), under the federal Clean Water Act (Section 303(d)), established a criterion not to exceed the TDG saturation level of 110% in order to protect freshwater and marine aquatic life. The states of Washington and Oregon have adopted special water quality standards for TDG saturation in the tailrace and forebays of hydropower facilities on the Columbia and Snake Rivers where spillway operations support fish passage objectives. The physical processes that affect TDG exchange at hydropower facilities have been studied throughout the CRB in site-specific studies and routine water quality monitoring programs. These data have been used to quantify the relationship between project operations, structural properties, and TDG exchange. These data have also been used to develop predictive models of TDG exchange to support real-time TDG management decisions. These empirically based predictive models have been developed for specific projects and account for both the fate of spillway and

  14. Do interindividual differences in cardiac output during submaximal exercise explain differences in exercising muscle oxygenation and ratings of perceived exertion?

    Science.gov (United States)

    Bentley, Robert F; Jones, Joshua H; Hirai, Daniel M; Zelt, Joel T; Giles, Matthew D; Raleigh, James P; Quadrilatero, Joe; Gurd, Brendon J; Neder, J Alberto; Tschakovsky, Michael E

    2018-01-01

    Considerable interindividual differences in the Q˙-V˙O2 relationship during exercise have been documented but implications for submaximal exercise tolerance have not been considered. We tested the hypothesis that these interindividual differences were associated with differences in exercising muscle deoxygenation and ratings of perceived exertion (RPE) across a range of submaximal exercise intensities. A total of 31 (21 ± 3 years) healthy recreationally active males performed an incremental exercise test to exhaustion 24 h following a resting muscle biopsy. Cardiac output (Q˙ L/min; inert gas rebreathe), oxygen uptake (V˙O2 L/min; breath-by-breath pulmonary gas exchange), quadriceps saturation (near infrared spectroscopy) and exercise tolerance (6-20; Borg Scale RPE) were measured. The Q˙-V˙O2 relationship from 40 to 160 W was used to partition individuals post hoc into higher (n = 10; 6.3 ± 0.4) versus lower (n = 10; 3.7 ± 0.4, P exercise (all P > 0.4). Lower cardiac responders had greater leg (P = 0.027) and whole body (P = 0.03) RPE only at 185 W, but this represented a higher %peak V˙O2 in lower cardiac responders (87 ± 15% vs. 66 ± 12%, P = 0.005). Substantially lower Q˙-V˙O2 in the lower responder group did not result in altered RPE or exercising muscle deoxygenation. This suggests substantial recruitment of blood flow redistribution in the lower responder group as part of protecting matching of exercising muscle oxygen delivery to demand. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  15. Fouling reduction characteristics of a no-distributor-fluidized-bed heat exchanger for flue gas heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Y.D.; Lee, K.B.; Islam, S.Z.; Ko, S.B. [Kongju National University, Kong Ju (Republic of Korea). Dept. for Mechanical Engineering

    2008-07-01

    In conventional flue gas heat recovery systems, the fouling by fly ashes and the related problems such as corrosion and cleaning are known to be major drawbacks. To overcome these problems, a single-riser no-distributor-fluidized-bed heat exchanger is devised and studied. Fouling and cleaning tests are performed for a uniquely designed fluidized bed-type heat exchanger to demonstrate the effect of particles on the fouling reduction and heat transfer enhancement. The tested heat exchanger model (1 m high and 54 mm internal diameter) is a gas-to-water type and composed of a main vertical tube and four auxiliary tubes through which particles circulate and transfer heat. Through the present study, the fouling on the heat transfer surface could successfully be simulated by controlling air-to-fuel ratios rather than introducing particles through an external feeder, which produced soft deposit layers with 1 to 1.5 mm thickness on the inside pipe wall. Flue gas temperature at the inlet of heat exchanger was maintained at 450{sup o}C at the gas volume rate of 0.738 to 0.768 CMM (0.0123 to 0.0128 m{sup 3}/sec). From the analyses of the measured data, heat transfer performances of the heat exchanger before and after fouling and with and without particles were evaluated. Results showed that soft deposits were easily removed by introducing glass bead particles, and also heat transfer performance increased two times by the particle circulation. In addition, it was found that this type of heat exchanger had high potential to recover heat of waste gases from furnaces, boilers, and incinerators effectively and to reduce fouling related problems.

  16. Nesting behaviour influences species-specific gas exchange across avian eggshells.

    Science.gov (United States)

    Portugal, Steven J; Maurer, Golo; Thomas, Gavin H; Hauber, Mark E; Grim, Tomáš; Cassey, Phillip

    2014-09-15

    Carefully controlled gas exchange across the eggshell is essential for the development of the avian embryo. Water vapour conductance (G(H2O)) across the shell, typically measured as mass loss during incubation, has been demonstrated to optimally ensure the healthy development of the embryo while avoiding desiccation. Accordingly, eggs exposed to sub-optimal gas exchange have reduced hatching success. We tested the association between eggshell G(H2O) and putative life-history correlates of adult birds, ecological nest parameters and physical characteristics of the egg itself to investigate how variation in G(H2O) has evolved to maintain optimal water loss across a diverse set of nest environments. We measured gas exchange through eggshell fragments in 151 British breeding bird species and fitted phylogenetically controlled, general linear models to test the relationship between G(H2O) and potential predictor parameters of each species. Of our 17 life-history traits, only two were retained in the final model: wet-incubating parent and nest type. Eggs of species where the parent habitually returned to the nest with wet plumage had significantly higher G(H2O) than those of parents that returned to the nest with dry plumage. Eggs of species nesting in ground burrows, cliffs and arboreal cups had significantly higher G(H2O) than those of species nesting on the ground in open nests or cups, in tree cavities and in shallow arboreal nests. Phylogenetic signal (measured as Pagel's λ) was intermediate in magnitude, suggesting that differences observed in the G(H2O) are dependent upon a combination of shared ancestry and species-specific life history and ecological traits. Although these data are correlational by nature, they are consistent with the hypothesis that parents constrained to return to the nest with wet plumage will increase the humidity of the nest environment, and the eggs of these species have evolved a higher G(H2O) to overcome this constraint and still

  17. Optimal allocation of leaf epidermal area for gas exchange

    OpenAIRE

    de Boer, Hugo J.; Price, Charles A.; Wagner-Cremer, Friederike; Dekker, Stefan C.; Franks, Peter J.; Veneklaas, Erik J.

    2016-01-01

    Summary A long?standing research focus in phytology has been to understand how plants allocate leaf epidermal space to stomata in order to achieve an economic balance between the plant's carbon needs and water use. Here, we present a quantitative theoretical framework to predict allometric relationships between morphological stomatal traits in relation to leaf gas exchange and the required allocation of epidermal area to stomata. Our theoretical framework was derived from first principles of ...

  18. Acclimation of a terrestrial plant to submergence facilitates gas exchange under water

    DEFF Research Database (Denmark)

    Mommer, L.; Pedersen, O.; Visser, E. J. W.

    2004-01-01

    Flooding imposes stress upon terrestrial plants since it severely hampers gas exchange rates between the shoot and the environment. The resulting oxygen deficiency is considered to be the major problem for submerged plants. Oxygen microelectrode studies have, however, shown that aquatic plants...... of this terrestrial plant species to submergence for gas exchange capacity is also shown. Shoot acclimation to submergence involved a reduction of the diffusion resistance to gases, which was not only functional by increasing diffusion of oxygen into the plant, but also by increasing influx of CO2, which enhances...... maintain relatively high internal oxygen pressures under water, and even may release oxygen via the roots into the sediment, also in dark. Based on these results, we challenge the dogma that oxygen pressures in submerged terrestrial plants immediately drop to levels at which aerobic respiration is impaired...

  19. The Precise Mechanisms of a High-Speed Ultrasound Gas Sensor and Detecting Human-Specific Lung Gas Exchange

    Directory of Open Access Journals (Sweden)

    Hideki Toda

    2012-12-01

    Full Text Available In this paper, we propose and develop a new real-time human respiration process analysis method using a high-time-sampling gas concentration sensor based on ultrasound. A unique point about our proposed gas concentration sensor is its 1 kHz gas concentration sampling speed. This figure could not have been attained by previously proposed gas concentration measurement methods such as InfraRed, semiconductor gas sensors, or GC-MS, because the gas analysis speeds were a maximum of a few hundred milliseconds. First, we describe the proposed new ultrasound sound speed measurement method and the signal processing, and present the measurement circuit diagram. Next, we analyse the human respiration gas variation patterns of five healthy subjects using a newly developed gas-mask-type respiration sensor. This reveals that the rapid gas exchange from H2O to CO2 contains air specific to the human being. In addition, we also measured medical symptoms in subjects suffering from asthma, hyperventilation and bronchial asthma. The millisecond level high-speed analysis of the human respiration process will be useful for the next generation of healthcare, rehabilitation and sports science technology.

  20. Seasonal trends in reduced leaf gas exchange and ozone-induced foliar injury in three ozone sensitive woody plant species

    International Nuclear Information System (INIS)

    Novak, K.; Schaub, M.; Fuhrer, J.; Skelly, J.M.; Hug, C.; Landolt, W.; Bleuler, P.; Kraeuchi, N.

    2005-01-01

    Seasonal trends in leaf gas exchange and ozone-induced visible foliar injury were investigated for three ozone sensitive woody plant species. Seedlings of Populus nigra L., Viburnum lantana L., and Fraxinus excelsior L. were grown in charcoal-filtered chambers, non-filtered chambers and open plots. Injury assessments and leaf gas exchange measurements were conducted from June to October during 2002. All species developed typical ozone-induced foliar injury. For plants exposed to non-filtered air as compared to the charcoal-filtered air, mean net photosynthesis was reduced by 25%, 21%, and 18% and mean stomatal conductance was reduced by 25%, 16%, and 8% for P. nigra, V. lantana, and F. excelsior, respectively. The timing and severity of the reductions in leaf gas exchange were species specific and corresponded to the onset of visible foliar injury. - Reductions in leaf gas exchange corresponded to the onset of ozone-induced visible foliar injury for seedlings exposed to ambient ozone exposures

  1. Seasonal trends in reduced leaf gas exchange and ozone-induced foliar injury in three ozone sensitive woody plant species

    Energy Technology Data Exchange (ETDEWEB)

    Novak, K. [Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Zuercherstrasse 111, 8903 Birmensdorf (Switzerland)]. E-mail: kristopher.novak@wsl.ch; Schaub, M. [Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Zuercherstrasse 111, 8903 Birmensdorf (Switzerland); Fuhrer, J. [Swiss Federal Research Station for Agroecology and Agriculture FAL, 8046 Zurich (Switzerland); Skelly, J.M. [Department of Plant Pathology, The Pennsylvania State University, University Park, PA 16802 (United States); Hug, C. [Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Zuercherstrasse 111, 8903 Birmensdorf (Switzerland); Landolt, W. [Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Zuercherstrasse 111, 8903 Birmensdorf (Switzerland); Bleuler, P. [Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Zuercherstrasse 111, 8903 Birmensdorf (Switzerland); Kraeuchi, N. [Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Zuercherstrasse 111, 8903 Birmensdorf (Switzerland)

    2005-07-15

    Seasonal trends in leaf gas exchange and ozone-induced visible foliar injury were investigated for three ozone sensitive woody plant species. Seedlings of Populus nigra L., Viburnum lantana L., and Fraxinus excelsior L. were grown in charcoal-filtered chambers, non-filtered chambers and open plots. Injury assessments and leaf gas exchange measurements were conducted from June to October during 2002. All species developed typical ozone-induced foliar injury. For plants exposed to non-filtered air as compared to the charcoal-filtered air, mean net photosynthesis was reduced by 25%, 21%, and 18% and mean stomatal conductance was reduced by 25%, 16%, and 8% for P. nigra, V. lantana, and F. excelsior, respectively. The timing and severity of the reductions in leaf gas exchange were species specific and corresponded to the onset of visible foliar injury. - Reductions in leaf gas exchange corresponded to the onset of ozone-induced visible foliar injury for seedlings exposed to ambient ozone exposures.

  2. Optimal technique for deep breathing exercises after cardiac surgery.

    Science.gov (United States)

    Westerdahl, E

    2015-06-01

    Cardiac surgery patients often develop a restrictive pulmonary impairment and gas exchange abnormalities in the early postoperative period. Chest physiotherapy is routinely prescribed in order to reduce or prevent these complications. Besides early mobilization, positioning and shoulder girdle exercises, various breathing exercises have been implemented as a major component of postoperative care. A variety of deep breathing maneuvres are recommended to the spontaneously breathing patient to reduce atelectasis and to improve lung function in the early postoperative period. Different breathing exercises are recommended in different parts of the world, and there is no consensus about the most effective breathing technique after cardiac surgery. Arbitrary instructions are given, and recommendations on performance and duration vary between hospitals. Deep breathing exercises are a major part of this therapy, but scientific evidence for the efficacy has been lacking until recently, and there is a lack of trials describing how postoperative breathing exercises actually should be performed. The purpose of this review is to provide a brief overview of postoperative breathing exercises for patients undergoing cardiac surgery via sternotomy, and to discuss and suggest an optimal technique for the performance of deep breathing exercises.

  3. Rate of Isotope Exchange Reaction Between Tritiated Water in a Gas Phase and Water on the Surface of Piping Materials

    International Nuclear Information System (INIS)

    Nakashio, Nobuyuki; Yamaguchi, Junya; Kobayashi, Ryusuke; Nishikawa, Masabumi

    2001-01-01

    The system effect of tritium arises from the interaction of tritium in the gas phase with water on the surface of piping materials. It has been reported that the system effect can be quantified by applying the serial reactor model to the piping system and that adsorption and isotope exchange reactions play the main roles in the trapping of tritium. The isotope exchange reaction that occurs when the chemical form of tritium in the gas phase is in the molecular form, i.e., HT or T 2 , has been named isotope exchange reaction 1, and that which occurs when tritium in the gas phase is in water form, i.e., HTO or T 2 O, has been named isotope exchange reaction 2.The rate of isotope exchange reaction 2 is experimentally quantified, and the rate is observed to be about one-third of the rate of adsorption. The trapping and release behavior of tritium from the piping surface due to isotope exchange reaction 2 is also discussed. It is certified that swamping of water vapor to process gas is effective to release tritium from the surface contaminated with tritium

  4. The Effect of Thermal Convection on Earth-Atmosphere CO2 Gas Exchange in Aggregated Soil

    Science.gov (United States)

    Ganot, Y.; Weisbrod, N.; Dragila, M. I.

    2011-12-01

    Gas transport in soils and surface-atmosphere gas exchange are important processes that affect different aspects of soil science such as soil aeration, nutrient bio-availability, sorption kinetics, soil and groundwater pollution and soil remediation. Diffusion and convection are the two main mechanisms that affect gas transport, fate and emissions in the soils and in the upper vadose zone. In this work we studied CO2 soil-atmosphere gas exchange under both day-time and night-time conditions, focusing on the impact of thermal convection (TCV) during the night. Experiments were performed in a climate-controlled laboratory. One meter long columns were packed with matrix of different grain size (sand, gravel and soil aggregates). Air with 2000 ppm CO2 was injected into the bottom of the columns and CO2 concentration within the columns was continuously monitored by an Infra Red Gas Analyzer. Two scenarios were compared for each soil: (1) isothermal conditions, representing day time conditions; and (2) thermal gradient conditions, i.e., atmosphere colder than the soil, representing night time conditions. Our results show that under isothermal conditions, diffusion is the major mechanism for surface-atmosphere gas exchange for all grain sizes; while under night time conditions the prevailing mechanism is dependent on the air permeability of the matrix: for sand and gravel it is diffusion, and for soil aggregates it is TCV. Calculated CO2 flux for the soil aggregates column shows that the TCV flux was three orders of magnitude higher than the diffusive flux.

  5. Physiological gas exchange mapping of hyperpolarized 129 Xe using spiral-IDEAL and MOXE in a model of regional radiation-induced lung injury.

    Science.gov (United States)

    Zanette, Brandon; Stirrat, Elaine; Jelveh, Salomeh; Hope, Andrew; Santyr, Giles

    2018-02-01

    To map physiological gas exchange parameters using dissolved hyperpolarized (HP) 129 Xe in a rat model of regional radiation-induced lung injury (RILI) with spiral-IDEAL and the model of xenon exchange (MOXE). Results are compared to quantitative histology of pulmonary tissue and red blood cell (RBC) distribution. Two cohorts (n = 6 each) of age-matched rats were used. One was irradiated in the right-medial lung, producing regional injury. Gas exchange was mapped 4 weeks postirradiation by imaging dissolved-phase HP 129 Xe using spiral-IDEAL at five gas exchange timepoints using a clinical 1.5 T scanner. Physiological lung parameters were extracted regionally on a voxel-wise basis using MOXE. Mean gas exchange parameters, specifically air-capillary barrier thickness (δ) and hematocrit (HCT) in the right-medial lung were compared to the contralateral lung as well as nonirradiated control animals. Whole-lung spectroscopic analysis of gas exchange was also performed. δ was significantly increased (1.43 ± 0.12 μm from 1.07 ± 0.09 μm) and HCT was significantly decreased (17.2 ± 1.2% from 23.6 ± 1.9%) in the right-medial lung (i.e., irradiated region) compared to the contralateral lung of the irradiated rats. These changes were not observed in healthy controls. δ and HCT correlated with histologically measured increases in pulmonary tissue heterogeneity (r = 0.77) and decreases in RBC distribution (r = 0.91), respectively. No changes were observed using whole-lung analysis. This work demonstrates the feasibility of mapping gas exchange using HP 129 Xe in an animal model of RILI 4 weeks postirradiation. Spatially resolved gas exchange mapping is sensitive to regional injury between cohorts that was undetected with whole-lung gas exchange analysis, in agreement with histology. Gas exchange mapping holds promise for assessing regional lung function in RILI and other pulmonary diseases. © 2017 The Authors. Medical Physics published by Wiley

  6. Carbon cycling and gas exchange in soils

    International Nuclear Information System (INIS)

    Trumbore, S.E.

    1989-01-01

    This thesis summaries three independent projects, each of which describes a method which can be used to study the role of soils in regulating the atmospheric concentrations of CO 2 and other trace gases. The first chapter uses the distribution of natural and bomb produced radiocarbon in fractionated soil organic matter to quantify the turnover of carbon in soils. A comparison of 137 Cs and 14 C in the modern soil profiles indicates that carbon is transported vertically in the soil as dissolved organic material. The remainder of the work reported is concerned with the use of inert trace gases to explore the physical factors which control the seasonal to diel variability in the fluxes of CO 2 and other trace gases from soils. Chapter 2 introduces a method for measuring soil gas exchange rates in situ using sulfur hexafluoride as a purposeful tracer. The measurement method uses standard flux box technology, and includes simultaneous determination of the fluxes and soil atmosphere concentrations of CO 2 and CH 4 . In Chapter 3, the natural tracer 222 Rn is used as an inert analog for exchange both in the soils and forest canopy of the Amazon rain forest

  7. Investigating onychophoran gas exchange and water balance as a means to inform current controversies in arthropod physiology.

    Science.gov (United States)

    Clusella-Trullas, Susana; Chown, Steven L

    2008-10-01

    Several controversies currently dominate the fields of arthropod metabolic rate, gas exchange and water balance, including the extent to which modulation of gas exchange reduces water loss, the origins of discontinuous gas exchange, the relationship between metabolic rate and life-history strategies, and the causes of Palaeozoic gigantism. In all of these areas, repeated calls have been made for the investigation of groups that might most inform the debates, especially of taxa in key phylogenetic positions. Here we respond to this call by investigating metabolic rate, respiratory water loss and critical oxygen partial pressure (Pc) in the onychophoran Peripatopsis capensis, a member of a group basal to the arthropods, and by synthesizing the available data on the Onychophora. The rate of carbon dioxide release (VCO2) at 20 degrees C in P. capensis is 0.043 ml CO2 h(-1), in keeping with other onychophoran species; suggesting that low metabolic rates in some arthropod groups are derived. Continuous gas exchange suggests that more complex gas exchange patterns are also derived. Total water loss in P. capensis is 57 mg H2O h(-1) at 20 degrees C, similar to modern estimates for another onychophoran species. High relative respiratory water loss rates ( approximately 34%; estimated using a regression technique) suggest that the basal condition in arthropods may be a high respiratory water loss rate. Relatively high Pc values (5-10% O2) suggest that substantial safety margins in insects are also a derived condition. Curling behaviour in P. capensis appears to be a strategy to lower energetic costs when resting, and the concomitant depression of water loss is a proximate consequence of this behaviour.

  8. Interruption to cutaneous gas exchange is not a likely mechanism of WNS-associated death in bats.

    Science.gov (United States)

    Carey, Charleve S; Boyles, Justin G

    2015-07-01

    Pseudogymnoascus destructans is the causative fungal agent of white-nose syndrome (WNS), an emerging fungal-borne epizootic. WNS is responsible for a catastrophic decline of hibernating bats in North America, yet we have limited understanding of the physiological interactions between pathogen and host. Pseudogymnoascus destructans severely damages wings and tail membranes, by causing dryness that leads to whole sections crumbling off. Four possible mechanisms have been proposed by which infection could lead to dehydration; in this study, we tested one: P. destructans infection could cause disruption to passive gas-exchange pathways across the wing membranes, thereby causing a compensatory increase in water-intensive pulmonary respiration. We hypothesized that total evaporative water loss would be greater when passive gas exchange was inhibited. We found that bats did not lose more water when passive pathways were blocked. This study provides evidence against the proposed proximal mechanism that disruption to passive gas exchange causes dehydration and death to WNS-infected bats. © 2015. Published by The Company of Biologists Ltd.

  9. Acclimation of a terrestrial plant to submergence facilitates gas exchange under water

    NARCIS (Netherlands)

    Mommer, L.; Pedersen, O.; Visser, E.J.W.

    2004-01-01

    Flooding imposes stress upon terrestrial plants since it severely hampers gas exchange rates between the shoot and the environment. The resulting oxygen deficiency is considered to be the major problem for submerged plants. Oxygen microelectrode studies have, however, shown that aquatic plants

  10. Leaf gas exchange characteristics of three neotropical mangrove species in response to varying hydroperiod

    Science.gov (United States)

    Krauss, Ken W.; Twilley, Robert R.; Doyle, Thomas W.; Gardiner, Emile S.

    2006-01-01

    We determined how different hydroperiods affected leaf gas exchange characteristics of greenhouse-grown seedlings (2002) and saplings (2003) of the mangrove species Avicennia germinans (L.) Stearn., Laguncularia racemosa (L.) Gaertn. f., and Rhizophora mangle L. Hydroperiod treatments included no flooding (unflooded), intermittent flooding (intermittent), and permanent flooding (flooded). Plants in the intermittent treatment were measured under both flooded and drained states and compared separately. In the greenhouse study, plants of all species maintained different leaf areas in the contrasting hydroperiods during both years. Assimilation–light response curves indicated that the different hydroperiods had little effect on leaf gas exchange characteristics in either seedlings or saplings. However, short-term intermittent flooding for between 6 and 22 days caused a 20% reduction in maximum leaf-level carbon assimilation rate, a 51% lower light requirement to attain 50% of maximum assimilation, and a 38% higher demand from dark respiration. Although interspecific differences were evident for nearly all measured parameters in both years, there was little consistency in ranking of the interspecific responses. Species by hydroperiod interactions were significant only for sapling leaf area. In a field study, R. mangle saplings along the Shark River in the Everglades National Park either demonstrated no significant effect or slight enhancement of carbon assimilation and water-use efficiency while flooded. We obtained little evidence that contrasting hydroperiods affect leaf gas exchange characteristics of mangrove seedlings or saplings over long time intervals; however, intermittent flooding may cause short-term depressions in leaf gas exchange. The resilience of mangrove systems to flooding, as demonstrated in the permanently flooded treatments, will likely promote photosynthetic and morphological adjustment to slight hydroperiod shifts in many settings..

  11. Optimal allocation of leaf epidermal area for gas exchange.

    Science.gov (United States)

    de Boer, Hugo J; Price, Charles A; Wagner-Cremer, Friederike; Dekker, Stefan C; Franks, Peter J; Veneklaas, Erik J

    2016-06-01

    A long-standing research focus in phytology has been to understand how plants allocate leaf epidermal space to stomata in order to achieve an economic balance between the plant's carbon needs and water use. Here, we present a quantitative theoretical framework to predict allometric relationships between morphological stomatal traits in relation to leaf gas exchange and the required allocation of epidermal area to stomata. Our theoretical framework was derived from first principles of diffusion and geometry based on the hypothesis that selection for higher anatomical maximum stomatal conductance (gsmax ) involves a trade-off to minimize the fraction of the epidermis that is allocated to stomata. Predicted allometric relationships between stomatal traits were tested with a comprehensive compilation of published and unpublished data on 1057 species from all major clades. In support of our theoretical framework, stomatal traits of this phylogenetically diverse sample reflect spatially optimal allometry that minimizes investment in the allocation of epidermal area when plants evolve towards higher gsmax . Our results specifically highlight that the stomatal morphology of angiosperms evolved along spatially optimal allometric relationships. We propose that the resulting wide range of viable stomatal trait combinations equips angiosperms with developmental and evolutionary flexibility in leaf gas exchange unrivalled by gymnosperms and pteridophytes. © 2016 The Authors New Phytologist © 2016 New Phytologist Trust.

  12. Contrasting dynamics of leaf potential and gas exchange during progressive drought cycles and recovery in Amorpha fruticosa and Robinia pseudoacacia.

    Science.gov (United States)

    Yan, Weiming; Zheng, Shuxia; Zhong, Yangquanwei; Shangguan, Zhouping

    2017-06-30

    Leaf gas exchange is closely associated with water relations; however, less attention has been given to this relationship over successive drought events. Dynamic changes in gas exchange and water potential in the seedlings of two woody species, Amorpha fruticosa and Robinia pseudoacacia, were monitored during recurrent drought. The pre-dawn leaf water potential declined in parallel with gas exchange in both species, and sharp declines in gas exchange occurred with decreasing water potential. A significant correlation between pre-dawn water potential and gas exchange was observed in both species and showed a right shift in R. pseudoacacia in the second drought. The results suggested that stomatal closure in early drought was mediated mainly by elevated foliar abscisic acid (ABA) in R. pseudoacacia, while a shift from ABA-regulated to leaf-water-potential-driven stomatal closure was observed in A. fruticosa. After re-watering, the pre-dawn water potential recovered quickly, whereas stomatal conductance did not fully recover from drought in R. pseudoacacia, which affected the ability to tightly control transpiration post-drought. The dynamics of recovery from drought suggest that stomatal behavior post-drought may be restricted mainly by hydraulic factors, but non-hydraulic factors may also be involved in R. pseudoacacia.

  13. Magnetic behavior of Van Vleck ions and an electron gas interacting by exchange

    International Nuclear Information System (INIS)

    Palermo, L.; Silva, X.A. da.

    1980-01-01

    The magnetic behavior of a model in which Van Vleck ions, under the action of a crystal field, interacting by exchange with an electron gas is investigated. The condition of onset of ferromagnetism and the behavior of the critical temperature, band and ionic magnetizations (and susceptibilities) versus temperature, as a function of the band width, exchange interaction and the crystal field splitting energy parameters are obtained within an approximation equivalent to a molecular field formulation. (Author) [pt

  14. Preliminary design analysis of hot gas ducts and a intermediate heat exchanger for the nuclear hydrogen reactor

    International Nuclear Information System (INIS)

    Song, K. N.; Kim, Y. W.

    2008-01-01

    Korea Atomic Energy Research Institute (KAERI) is in the process of carrying out a nuclear hydrogen system by considering the indirect cycle gas cooled reactors that produce heat at temperatures in the order of 950 .deg. C. Primary and secondary hot gas ducts with coaxial double tubes and are key components connecting a reactor pressure vessel and a intermediate heat exchanger for the nuclear hydrogen system. In this study, preliminary design analyses on the hot gas ducts and the intermediate heat exchanger were carried out. These preliminary design activities include a preliminary design on the geometric dimensions, a preliminary strength evaluation, thermal sizing, and an appropriate material selection

  15. Process for hydrogen isotope exchange and concentration between liquid water and hydrogen gas and catalyst assembly therefor

    International Nuclear Information System (INIS)

    Stevens, W.H.

    1975-01-01

    A bithermal, catalytic, hydrogen isotope exchange process between liquid water and hydrogen gas to effect concentration of the deuterium isotope of hydrogen is described. Liquid water and hydrogen gas are contacted with one another and with at least one catalytically active metal selected from Group VIII of the Periodic Table; the catalyst body has a water repellent, gas and water vapor permeable, organic polymer or resin coating, preferably a fluorinated olefin polymer or silicone resin coating, so that the isotope exchange takes place by two simultaneously occurring, and closely coupled in space, steps and concentration is effected by operating two interconnected sections containing catalyst at different temperatures. (U.S.)

  16. Preliminary findings of the Viking gas exchange experiment and a model for Martian surface chemistry

    International Nuclear Information System (INIS)

    Oyama, V.I.; Berdahl, B.J.; Carle, G.C.

    1977-01-01

    It is stated that O 2 and CO 2 were evolved from humidified Martian soil in the gas exchange experiment on Viking Lander 1. Small changes in N 2 gas were also recorded. A model of the morphology and a hypothesis of the mechanistics of the Martian surface are proposed. (author)

  17. Improved spacers for high temperature gas-cooled heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Nordstroem, L A [Swiss Federal Institute for Reactor Research, Wuerenlingen (Switzerland)

    1984-07-01

    Experimental and analytical investigations in the field of heat exchanger thermohydraulics have been performed at EIR for many years, Basic studies have been carried out on heat transfer and pressure loss for tube bundles of different geometries and tube surfaces. As a part of this overall R+D programme for heat exchangers, investigations have been carried out on spacer pressure loss in bundles with longitudinal flow. An analytical spacer pressure loss model was developed which could handle different types of subchannel within the bundle. The model has been evaluated against experiments, using about 25 spacers of widely differing geometries. In a gas-cooled reactor it is important to keep the pressure loss over the primary circuit heat exchangers to a minimum. In exchangers with grid spacers these contribute a significant proportion of the overall bundle losses. For example, in the HHT Recuperator, with a shell-side pressure loss of 3.5 % of the inlet pressure, the spacers cause about one half of this loss. Reducing the loss to, say, 2.5 % results in an overall increase in plant efficiency by more than 1 % - a significant improvement Preliminary analysis identified 5 geometries in particular which were chosen for experimental evaluation as part of a joint project with the SULZER Company, to develop a low pressure-loss spacer for HHT heat exchangers (longitudinal counter-flow He/He and He/H{sub 2}O designs). The aim of the tests was to verify the low pressure-loss characteristics of these spacer grid types, as well as the quality of the results calculated by the computer code analytical model. The experimental and analytical results are compared in this report.

  18. Stress responses during aerobic exercise in relation to motivational dominance and state.

    Science.gov (United States)

    Thatcher, Joanne; Kuroda, Yusuke; Legrand, Fabien D; Thatcher, Rhys

    2011-02-01

    We examined the hypothesis that congruence between motivational dominance and state results in optimal psychological responses and performance during exercise. Twenty participants (10 telic dominant and 10 paratelic dominant) rated their stress at 5 min intervals as they cycled on an ergometer at gas exchange threshold for 30 min in both telic and paratelic state manipulated conditions. Participants then performed a test to exhaustion at a resistance equivalent to 110% of VO(2max). The hypothesized interaction between condition and dominance was significant for internal tension stress, as paratelic dominants were more stressed than telic dominants when exercising in the telic state and telic dominants were more stressed than paratelic dominants when exercising in the paratelic state. Similarly, the condition × dominance interaction for internal stress discrepancy was significant, as paratelic dominants reported greater internal stress discrepancy exercising in the telic compared with the paratelic state. Findings are discussed in relation to the application of reversal theory for understanding stress responses during aerobic exercise.

  19. Leaf gas exchange of understory spruce-fir saplings in relict cloud forests, southern Appalachian Mountains, USA

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, K.; Smith, W.K. [Wake Forest Univ., Winston-Salem, NC (United States). Dept. of Biology

    2008-01-15

    Global climate change is expected to increase regional cloud ceiling levels in many mountainous forested areas of the world. This study investigated environmental influences on the gas exchange physiology of understory red spruce and Fraser fir trees at 2 sites in the Appalachian mountains. The study hypothesized that the humid, cloudy environment would influence the photosynthetic performance of the trees, and that the species would adapt to low, diffuse light. The study also predicted that leaf conductance to carbon dioxide (CO{sub 2}) would be high as a result of low leaf-to-air-vapour pressure deficit (LAVD). The study demonstrated that leaf conductance decreased exponentially as LAVD increased. Predawn leaf water potentials remained stable, while late afternoon values declined. It was concluded that leaf gas exchange was correlated with the response of leaf conductance and LAVD. The cloudy, humid environment strongly influenced tree leaf gas exchange and water relations. It was suggested that further research is needed to investigate cloud impacts on carbon gain and water relations. 72 refs., 1 tab., 8 figs.

  20. Increasing the pump-up rate to polarize 3He gas using spin-exchange optical pumping method

    International Nuclear Information System (INIS)

    Lee, W.T.; Tong Xin; Rich, Dennis; Liu Yun; Fleenor, Michael; Ismaili, Akbar; Pierce, Joshua; Hagen, Mark; Dadras, Jonny; Robertson, J. Lee

    2009-01-01

    In recent years, polarized 3 He gas has increasingly been used as neutron polarizers and polarization analyzers. Two of the leading methods to polarize the 3 He gas are the spin-exchange optical pumping (SEOP) method and the meta-stable exchange optical pumping (MEOP) method. At present, the SEOP setup is comparatively compact due to the fact that it does not require the sophisticated compressor system used in the MEOP method. The temperature and the laser power available determine the speed, at which the SEOP method polarizes the 3 He gas. For the quantity of gas typically used in neutron scattering work, this speed is independent of the quantity of the gas required, whereas the polarizing time using the MEOP method is proportional to the quantity of gas required. Currently, using the SEOP method to polarize several bar-liters of 3 He to 70% polarization would require 20-40 h. This is an order of magnitude longer than the MEOP method for the same quantity of gas and polarization. It would therefore be advantageous to speed up the SEOP process. In this article, we analyze the requirements for temperature, laser power, and the type of alkali used in order to shorten the time required to polarize 3 He gas using the SEOP method.

  1. Exercise testing in asymptomatic or minimally symptomatic aortic regurgitation: relationship of left ventricular ejection fraction to left ventricular filling pressure during exercise

    International Nuclear Information System (INIS)

    Boucher, C.A.; Wilson, R.A.; Kanarek, D.J.; Hutter, A.M. Jr.; Okada, R.D.; Liberthson, R.R.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Exercise radionuclide angiography is being used to evaluate left ventricular function in patients with aortic regurgitation. Ejection fraction is the most common variable analyzed. To better understand the rest and exercise ejection fraction in this setting, 20 patients with asymptomatic or minimally symptomatic severe aortic regurgitation were studied. All underwent simultaneous supine exercise radionuclide angiography and pulmonary gas exchange measurement and underwent rest and exercise measurement of pulmonary artery wedge pressure (PAWP) during cardiac catheterization. Eight patients had a peak exercise PAWP less than 15 mm Hg (group 1) and 12 had a peak exercise PAWP greater than or equal to 15 mm Hg (group 2). Group 1 patients were younger and more were in New York Heart Association class I. The two groups had similar cardiothoracic ratios, changes in ejection fractions with exercise, and rest and exercise regurgitant indexes. Using multiple regression analysis, the best correlate of the exercise PAWP was peak oxygen uptake (r . -0.78, p less than 0.01). No other measurement added significantly to the regression. When peak oxygen uptake was excluded, rest and exercise ejection fraction also correlated significantly (r . -0.62 and r . -0.60, respectively, p less than 0.01). Patients with asymptomatic or minimally symptomatic severe aortic regurgitation have a wide spectrum of cardiac performance in terms of the PAWP during exercise. The absolute rest and exercise ejection fraction and the level of exercise achieved are noninvasive variables that correlate with exercise PAWP in aortic regurgitation, but the change in ejection fraction with exercise by itself is not

  2. Organic iodine removal from simulated dissolver off-gas systems utilizing silver-exchanged mordenite

    International Nuclear Information System (INIS)

    Jubin, R.T.

    1981-01-01

    The removal of methyl iodide by adsorption onto silver mordenite was studied using a simulated off-gas from the fuel dissolution step of a nuclear fuel reprocessing plant. The adsorption of methyl iodide on silver mordenite was examined for the effect of NO/sub x/, humidity, iodine concentration, filter temperature, silver loadings and filter pretreatment. The highest iodine loading achieved in these tests was 142 mg CH 3 I per g of substrate on fully exchanged zeolite, approximately the same as elemental iodine loadings. A filter using fully exchanged silver mordenite operating at 200 0 C obtained higher iodine loadings than a similar filter operating at 150 0 C. Pretreatment of the sorbent bed with hydrogen rather than dry air, at a temperature of 200 0 C, also improved the loading. Variations in the methyl iodide concentration had minimal effects on the overall loading. Filters exposed to moist air streams attained higher loadings than those in contact with dry air. Partially exchanged silver mordenite achieved higher silver utilizations than the fully exchanged material. The partially exchanged mordenite also achieved higher loadings at 200 0 C than at 250 0 C. The iodine loaded onto these beds was not stripped at 500 0 C by either 4.5% hydrogen or 100% hydrogen; however, the iodine could be removed by air at 500 0 C, and the bed could be reloaded. A study of the regeneration characteristics of fully exchanged silver mordenite indicates limited adsorbent capacity after complete removal of the iodine with 4.5% hydrogen in the regeneration gas stream at 500 0 C. The loss of adsorbent capacity is much higher for silver mordenite regenerated in a stainless steel filter housing than in a glass filter housing

  3. Technical Of The Heat Exchanger System Of RSG-GAS Maintenance

    International Nuclear Information System (INIS)

    Murjati, Bambang; Tarigan, Alim; Saepudin C, Aep

    2001-01-01

    This first overhaul of RSG-GAS heat exchanger (HE 01) after 13 years operation had been done in May 29 until June 2, 2000. The result showed that the dimension of the some holes at the inlet side of HE 01 has shrunk but not at the outlet side. The shrank holes, then were cleaned using jet cleaner and aluminium pipe. The overhaul of HE 02 will be performed in the next period

  4. A New, Noninvasive Method of Measuring Impaired Pulmonary Gas Exchange in Lung Disease: An Outpatient Study.

    Science.gov (United States)

    West, John B; Crouch, Daniel R; Fine, Janelle M; Makadia, Dipen; Wang, Daniel L; Prisk, G Kim

    2018-02-13

    It would be valuable to have a noninvasive method of measuring impaired pulmonary gas exchange in patients with lung disease and thus reduce the need for repeated arterial punctures. This study reports the results of using a new test in a group of outpatients attending a pulmonary clinic. Inspired and expired partial pressure of oxygen (PO 2 ) and Pco 2 are continually measured by small, rapidly responding analyzers. The arterial PO 2 is calculated from the oximeter blood oxygen saturation level and the oxygen dissociation curve. The PO 2 difference between the end-tidal gas and the calculated arterial value is called the oxygen deficit. Studies on 17 patients with a variety of pulmonary diseases are reported. The mean ± SE oxygen deficit was 48.7 ± 3.1 mm Hg. This finding can be contrasted with a mean oxygen deficit of 4.0 ± 0.88 mm Hg in a group of 31 normal subjects who were previously studied (P gas in determining ventilation-perfusion ratio inequality. This factor is largely ignored in the classic index of impaired pulmonary gas exchange using the ideal alveolar PO 2 to calculate the alveolar-arterial oxygen gradient. The results previously reported in normal subjects and the present studies suggest that this new noninvasive test will be valuable in assessing abnormal gas exchange in the clinical setting. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  5. Use of 'ideal' alveolar air equations and corrected end-tidal PCO2 to estimate arterial PCO2 and physiological dead space during exercise in patients with heart failure.

    Science.gov (United States)

    Van Iterson, Erik H; Olson, Thomas P

    2018-01-01

    Arterial CO 2 tension (PaCO 2 ) and physiological dead space (V D ) are not routinely measured during clinical cardiopulmonary exercise testing (CPET). Abnormal changes in PaCO 2 accompanied by increased V D directly contribute to impaired exercise ventilatory function in heart failure (HF). Because arterial catheterization is not standard practice during CPET, this study tested the construct validity of PaCO 2 and V D prediction models using 'ideal' alveolar air equations and basic ventilation and gas-exchangegas exchange measurements during CPET in HF. Forty-seven NYHA class II/III HF (LVEF=21±7%; age=55±9years; male=89%; BMI=28±5kg/m 2 ) performed step-wise cycle ergometry CPET to volitional fatigue. Breath-by-breath ventilation and gas exchange were measured continuously. Steady-state PaCO 2 was measured at rest and peak exercise via radial arterial catheterization. Criterion V D was calculated via 'ideal' alveolar equations, whereas PaCO 2 or V D models were based on end-tidal CO 2 tension (P ET CO 2 ), tidal volume (V T ), and/or weight. Criterion measurements of PaCO 2 (38±5 vs. 33±5mmHg, Pgas exchange and ventilatory responses demonstrate acceptable agreement with criterion measurements at peak exercise in HF patients. Routine assessment of PaCO 2 and V D can be used to improve interpretability of exercise ventilatory responses in HF. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  6. The conditions for exercising eligibility for natural gas purchasing

    International Nuclear Information System (INIS)

    Anon.

    2005-01-01

    Since the electricity and natural gas markets were opened to all non-household customers, the CRE (the French commission of energy regulation) has received requests for information about the conditions for exercising eligibility, coming mainly from consumers with questions about the diverging practices of historical suppliers. The commission therefore launched a public investigation into this subject in 2004. Out of the 38 responses received, some criticized the way in which access to the network operates and the conditions for market opening while others raised questions falling outside the direct scope of the public investigation. The CRE's answers to these observations are explained in this article

  7. Numerical Study of Compact Plate-Fin Heat Exchanger for Rotary-Vane Gas Refrigeration Machine

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2017-10-01

    Full Text Available Plate-fin heat exchangers are widely used in refrigeration technique. They are popular because of their compactness and excellent heat transfer performance. Here we present a numerical model for the development, research and optimization of a plate-fin heat exchanger for a rotary-vane gas refrigeration machine. The method of analysis by graphic method of plate - fin heat exchanger is proposed. The model describes the effects of secondary parameters such as axial thermal conductivity through a metal matrix of the heat exchanger. The influence of geometric parameters and heat transfer coefficient is studied. Graphs of dependences of length, efficiency of a fin and pressure drop in a heat exchanger on the thickness of the fin and the number of fins per meter are obtained. To analyze the results of numerical simulation, the heat exchanger was designed in the Aspen HYSYS program. The simulation results show that the total deviation from the proposed numerical model is not more than 15%. 

  8. Aerobic exercise training reduces arterial stiffness in metabolic syndrome.

    Science.gov (United States)

    Donley, David A; Fournier, Sara B; Reger, Brian L; DeVallance, Evan; Bonner, Daniel E; Olfert, I Mark; Frisbee, Jefferson C; Chantler, Paul D

    2014-06-01

    The metabolic syndrome (MetS) is associated with a threefold increase risk of cardiovascular disease (CVD) mortality partly due to increased arterial stiffening. We compared the effects of aerobic exercise training on arterial stiffening/mechanics in MetS subjects without overt CVD or type 2 diabetes. MetS and healthy control (Con) subjects underwent 8 wk of exercise training (ExT; 11 MetS and 11 Con) or remained inactive (11 MetS and 10 Con). The following measures were performed pre- and postintervention: radial pulse wave analysis (applanation tonometry) was used to measure augmentation pressure and index, central pressures, and an estimate of myocardial efficiency; arterial stiffness was assessed from carotid-femoral pulse-wave velocity (cfPWV, applanation tonometry); carotid thickness was assessed from B-mode ultrasound; and peak aerobic capacity (gas exchange) was performed in the seated position. Plasma matrix metalloproteinases (MMP) and CVD risk (Framingham risk score) were also assessed. cfPWV was reduced (P Exercise training reduced (P exercise training, thereby lowering their cardiovascular risk. Copyright © 2014 the American Physiological Society.

  9. Exercise attenuates intermittent hypoxia-induced cardiac fibrosis associated with sodium-hydrogen exchanger-1 in rats

    Directory of Open Access Journals (Sweden)

    Tsung-I Chen

    2016-10-01

    Full Text Available Purpose: To investigate the role of sodium–hydrogen exchanger-1 (NHE-1 and exercise training on intermittent hypoxia-induced cardiac fibrosis in obstructive sleep apnea (OSA, using an animal model mimicking the intermittent hypoxia of OSA. Methods: Eight-week-old male Sprague–Dawley rats were randomly assigned to control (CON, intermittent hypoxia (IH, exercise (EXE or IH combined with exercise (IHEXE groups. These groups were randomly assigned to subgroups receiving either a vehicle or the NHE-1 inhibitor cariporide. The EXE and IHEXE rats underwent exercise training on an animal treadmill for 10 weeks (5 days/week, 60 minutes/day, 24–30 m/minute, 2–10% grade. The IH and IHEXE rats were exposed to 14 days of IH (30 seconds of hypoxia - nadir of 2-6% O2 - followed by 45 seconds of normoxia for 8 hours/day. At the end of 10 weeks, rats were sacrificed and then hearts were removed to determine the myocardial levels of fibrosis index, oxidative stress, antioxidant capacity and NHE-1 activation. Results: Compared to the CON rats, IH induced higher cardiac fibrosis, lower myocardial catalase and superoxidative dismutase activities, higher myocardial lipid and protein peroxidation and higher NHE-1 activation (p < 0.05 for each, which were all abolished by cariporide. Compared to the IH rats, lower cardiac fibrosis, higher myocardial antioxidant capacity, lower myocardial lipid and protein peroxidation and lower NHE-1 activation were found in the IHEXE rats (p < 0.05 for each. Conclusion: IH-induced cardiac fibrosis was associated with NHE-1 hyperactivity. However, exercise training and cariporide exerted an inhibitory effect to prevent myocardial NHE-1 hyperactivity, which contributed to reduced IH-induced cardiac fibrosis. Therefore, NHE-1 plays a critical role in the effect of exercise on IH-induced increased cardiac fibrosis.

  10. Hypertension is associated with greater heat exchange during exercise recovery in a hot environment.

    Science.gov (United States)

    Fonseca, S F; Teles, M C; Ribeiro, V G C; Magalhães, F C; Mendonça, V A; Peixoto, M F D; Leite, L H R; Coimbra, C C; Lacerda, A C R

    2015-12-01

    Individuals with systemic arterial hypertension have a higher risk of heat-related complications. Thus, the aim of this study was to examine the thermoregulatory responses of hypertensive subjects during recovery from moderate-intensity exercise performed in the heat. A total of eight essential hypertensive (H) and eight normotensive (N) male subjects (age=46.5±1.3 and 45.6±1.4 years, body mass index=25.8±0.8 and 25.6±0.6 kg/m2, mean arterial pressure=98.0±2.8 and 86.0±2.3 mmHg, respectively) rested for 30 min, performed 1 h of treadmill exercise at 50% of maximal oxygen consumption, and rested for 1 h after exercise in an environmental chamber at 38°C and 60% relative humidity. Skin and core temperatures were measured to calculate heat exchange parameters. Mean arterial pressure was higher in the hypertensive than in the normotensive subjects throughout the experiment (Phypertensive subjects stored less heat (H=-24.23±3.99 W·m-2vs N=-13.63±2.24 W·m-2, P=0.03, unpaired t-test), experienced greater variations in body temperature (H=-0.62±0.05°C vsN=-0.35±0.12°C, P=0.03, unpaired t-test), and had more evaporated sweat (H=-106.1±4.59 W·m-2vs N=-91.15±3.24 W·m-2, P=0.01, unpaired t-test) than the normotensive subjects during the period of recovery from exercise. In conclusion, essential hypertensive subjects showed greater sweat evaporation and increased heat dissipation and body cooling relative to normotensive subjects during recovery from moderate-intensity exercise performed in hot conditions.

  11. The American Foreign Exchange Option in Time-Dependent One-Dimensional Diffusion Model for Exchange Rate

    International Nuclear Information System (INIS)

    Rehman, Nasir; Shashiashvili, Malkhaz

    2009-01-01

    The classical Garman-Kohlhagen model for the currency exchange assumes that the domestic and foreign currency risk-free interest rates are constant and the exchange rate follows a log-normal diffusion process.In this paper we consider the general case, when exchange rate evolves according to arbitrary one-dimensional diffusion process with local volatility that is the function of time and the current exchange rate and where the domestic and foreign currency risk-free interest rates may be arbitrary continuous functions of time. First non-trivial problem we encounter in time-dependent case is the continuity in time argument of the value function of the American put option and the regularity properties of the optimal exercise boundary. We establish these properties based on systematic use of the monotonicity in volatility for the value functions of the American as well as European options with convex payoffs together with the Dynamic Programming Principle and we obtain certain type of comparison result for the value functions and corresponding exercise boundaries for the American puts with different strikes, maturities and volatilities.Starting from the latter fact that the optimal exercise boundary curve is left continuous with right-hand limits we give a mathematically rigorous and transparent derivation of the significant early exercise premium representation for the value function of the American foreign exchange put option as the sum of the European put option value function and the early exercise premium.The proof essentially relies on the particular property of the stochastic integral with respect to arbitrary continuous semimartingale over the predictable subsets of its zeros. We derive from the latter the nonlinear integral equation for the optimal exercise boundary which can be studied by numerical methods

  12. Apneic oxygenation combined with extracorporeal arteriovenous carbon dioxide removal provides sufficient gas exchange in experimental lung injury

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Kjærgaard, Benedict; Nielsen, Jakob Koefoed

    In this porcine lung injury model, apneic oxygenation with arteriovenous CO2 removal provided sufficient gas exchange and stable hemodynamics, indicating that the method might have a potential in the treatment of severe ARDS.   Acknowledgements The membrane lungs were kindly provided by Novalung GmbH, Germany.......Background and aim of study We hypothesized that continuous high airway pressure without ventilatory movements (apneic oxygenation), using an open lung approach, combined with extracorporeal, pumpless, arterio-venous, carbon dioxide (CO2) removal would provide adequate gas exchange in acute lung...

  13. Underwater photosynthesis and respiration in leaves of submerged wetland plants: gas films improve CO2 and O2 exchange

    DEFF Research Database (Denmark)

    Colmer, Timothy David; Pedersen, Ole

    2007-01-01

    (N) was enhanced up to sixfold. Gas films on submerged leaves enable continued gas exchange via stomata and thus bypassing of cuticle resistance, enhancing exchange of O(2) and CO(2) with the surrounding water, and therefore underwater P(N) and respiration.......Many wetland plants have gas films on submerged leaf surfaces. We tested the hypotheses that leaf gas films enhance CO(2) uptake for net photosynthesis (P(N)) during light periods, and enhance O(2) uptake for respiration during dark periods. Leaves of four wetland species that form gas films......, and two species that do not, were used. Gas films were also experimentally removed by brushing with 0.05% (v/v) Triton X. Net O(2) production in light, or O(2) consumption in darkness, was measured at various CO(2) and O(2) concentrations. When gas films were removed, O(2) uptake in darkness was already...

  14. Tracers of air-sea gas exchange

    International Nuclear Information System (INIS)

    Liss, P.S.

    1988-01-01

    The flux of gas across the air-sea interface is determined by the product of the interfacial concentration difference driving the exchange and a rate constant, often termed the transfer velocity. The concentration-difference term is generally obtained by direct measurement, whereas more indirect approaches are required to estimate the transfer velocity and its variation as a function of controlling parameters such as wind and sea state. Radioactive tracers have proved particularly useful in the estimation of air-sea transfer velocities and, recently, stable purposeful tracers have also started to be used. In this paper the use of the following tracers to determine transfer velocities at the sea surface is discussed: natural and bomb-produced 14 C, dissolved oxygen, 222 Rn and sulphur hexafluoride. Other topics covered include the relation between transfer velocity and wind speed as deduced from tracer and wind-tunnel studies, and the discrepancy between transfer velocities determined by using tracers and from eddy correlation measurements in the atmosphere. (author)

  15. Gas-exchange patterns of Mediterranean fruit fly Pupae (Diptera: Tephritidae): A tool to forecast developmental stage

    International Nuclear Information System (INIS)

    Nestel, D.; Nemny-Lavy, E.; Alchanatis, V.

    2007-01-01

    The pattern of gas-exchange (CO 2 emission) was investigated for developing Mediterranean fruit fly (medfly) Ceratitis capitata (Wiedemann) pupae incubated at different temperatures. This study was undertaken to explore the usefulness of gas-exchange systems in the determination of physiological age in developing pupae that are mass produced for sterile insect technique projects. The rate of CO 2 emission was measured in a closed flow-through system connected to commercial infrared gas analysis equipment. Metabolic activity (rate of CO 2 emission) was related to pupal eye-color, which is the current technique used to determine physiological age. Eye-color was characterized digitally with 3 variables (Hue, Saturation and Intensity), and color separated by discriminant analysis. The rate of CO 2 emission throughout pupal development followed a U-shape, with high levels of emission during pupariation, pupal transformation and final pharate adult stages. Temperature affected the development time of pupae, but not the basic CO 2 emission patterns during development. In all temperatures, rates of CO 2 emission 1 and 2 d before adult emergence were very similar. After mid larval-adult transition (e.g., phanerocephalic pupa), digital eye-color was significantly correlated with CO 2 emission. Results support the suggestion that gas-exchange should be explored further as a system to determine pupal physiological age in mass production of fruit flies. (author) [es

  16. Insulin resistance, exercise capacity and body composition in subjects with two hypertensive parents

    DEFF Research Database (Denmark)

    Andersen, U B; Dige-Petersen, H; Ibsen, H

    1999-01-01

    -ray absorptiometry; (4) an exercise test with gas exchange analysis; and (5) investigation of composition of usual diet by diet registration for 5 days. RESULTS: The 24-h diastolic blood pressure was higher in subjects predisposed to hypertension compared with the controls: 78.1 versus 74.0 mmHg (confidence interval...... for the difference between the means; -0.5; -7.9), but the insulin sensitivity index was similar: 312 versus 362 I(2) min(-1) pmol(-1) kg(-1) (28; -129). The two groups were similar in terms of body composition, exercise capacity and composition of usual diet. Resting and 24-h diastolic blood pressures were...

  17. Water status and gas exchange of umbu plants (Spondias tuberosa Arr. Cam.) propagated by seeds and stem cuttings.

    OpenAIRE

    LIMA FILHO, J. M. P.

    2008-01-01

    The experiment was carried out at the Embrapa Semi-Árido, Petrolina-PE, Brazil, in order to study the physiological responses of umbu plants propagated by seeds and by stem cuttings under water stress conditions, based on leaf water potential and gas exchange measurements. Data were collected in one-year plants established in pots containing 30 kg of a sandy soil and submitted to twenty-day progressive soil water deficit. The evaluations were based on leaf water potential and gas exchange dat...

  18. Preheating of manure utilizing heat exchanger and flue gas. Forvarmning af gylle ved varmeveksling med roeggas

    Energy Technology Data Exchange (ETDEWEB)

    Weber, J.

    1987-07-15

    It has been shown that preheating of manures in biomass conversion plants to a temperature of 50-60 deg. C, before the anaerobic digestion takes place at a temperature of 35-45 deg. C, results in an increase of methane production. But the method normally involves an increase in energy consumption. The aim of the project was to develope methods of utilizing heat from flue gas emitted from the boiler connected to the plant, with the help of a heat exchanger. The heat thus recovered would be used to preheat the manure. The chosen method was to inject the flue gas directly into the manure mass, following this up with heat exchanging and condensing. In order to mix the flue gas thoroughly into the manure an ejector was used, this was driven by the manure flow. Results were satisfactory. (AB).

  19. Investigation of gas flow characteristics in proton exchange membrane fuel cell

    International Nuclear Information System (INIS)

    Kwac, Lee Ku; Kim, Hong Gun

    2008-01-01

    An investigation of electrochemical behavior of PEMFC (proton exchange membrane fuel cell) is performed by using a single-phase two-dimensional finite element analysis. Equations of current balance, mass balance, and momentum balance are implemented to simulate the behavior of PEMFC. The analysis results for the co-flow and counterflow mode of gas flow direction are examined in detail in order to compare how the gas flow direction affects quantitatively. The characteristics of internal properties, such as gas velocity distribution, mass fraction of the reactants, fraction of water and current density distribution in PEMFC are illustrated in the electrode and GDL (gas diffusion layer). It is found that the dry reactant gases can be well internally humidified and maintain high performance in the case of the counter-flow mode without external humidification while it is not advantageous for highly humidified or saturated reactant gases. It is also found that the co-flow mode improves the current density distribution with humidified normal condition compared to the counter-flow mode

  20. [To exercise caution in developing intraocular lens exchange].

    Science.gov (United States)

    Song, X D; Wang, X Z; Qian, J

    2018-05-11

    Nowadays cataract extraction combined intraocular lens (IOL) implantation has become the conventional treatment for cataract. Numbers of IOL exchange after cataract extraction combined IOL implantation have been increasing in recent years. As a non-routine surgery, IOL exchange is normally combined with other surgeries and accompanied by some complications to various extents. Is IOL exchange necessary for all abnomal IOLs? Can IOL exchange be avoided? How to avoid IOL exchange? The purpose of this article is to stress the importance of indication of IOL exchange and how to avoid IOL exchange. (Chin J Ophthalmol, 2018, 54: 324-327) .

  1. Vibrations in water-gas heat exchangers. Design and tests

    International Nuclear Information System (INIS)

    Alexandre, M.; Allard, G.; Vangedhen, A.

    1981-01-01

    It is shown on an example how to make a complete list of the possible vibrations and how to use the data of tests and technical literature to predict damaging vibrations. The water-heavy gas tubular heat-exchanger in case is briefly described. The sources of mechanical excitations are a compressor and earthquake loadings. The various eigenmodes are described and it is shown that no resonance is possible with the compressor and that the effect of the earthquake is negligible. The excitation of the tubes by the gas flow is examined by means of Connors stability criterion; and there is no resonance with the Benard-von Karman vortices. The magnification of this latter excitation by acoustical waves is not to be feared. Satisfactory tests have been carried successively on tubes, on the casing, on the casing plus part of the tubes, on a complete prototype in workshop and in operation on site [fr

  2. Heat Exchange and Fouling Analysis on a Set of Hydrogen Sulphide Gas Coolers

    Directory of Open Access Journals (Sweden)

    Andrés Adrian Sánchez-Escalona

    2017-07-01

    Full Text Available The sulphide acid coolers are tube and shell jacketed heat exchangers designed to cool down the produced gas from 416,15 K to 310,15 K in addition to separate the sulphur carried over by the outlet gas from the reactor tower. The investigation was carried out by applying the passive experimentation process in an online cooler set in order to determine the heat transfer rates and fouling based on heat resistance. It was corroborated that the operation of this equipment outside design parameters increases outlet gas temperature and liquid sulphur carryovers. Efficiency loss is caused by fouling elements in the fluid, which results in changes in the overall heat transfer rate. The linear tendency of the fouling heat resistance based on time for three gas flowrates.

  3. Atmospheric deposition and air-sea gas exchange fluxes of DDT and HCH in the Yangtze River Estuary, East China Sea

    Science.gov (United States)

    Li, Zhongxia; Lin, Tian; Li, Yuanyuan; Jiang, Yuqing; Guo, Zhigang

    2017-07-01

    The Yangtze River Estuary (YRE) is strongly influenced by the Yangtze River and lies on the pathway of the East Asian Monsoon. This study examined atmospheric deposition and air-sea gas exchange fluxes of dichlorodiphenyltrichloroethane (DDT) and hexachlorocyclohexane (HCH) to determine whether the YRE is a sink or source of selected pesticides at the air-water interface under the influences of river input and atmospheric transport. The air-sea gas exchange of DDT was characterized by net volatilization with a marked difference in its fluxes between summer (140 ng/m2/d) and the other three seasons (12 ng/m2/d), possibly due to the high surface seawater temperatures and larger riverine input in summer. However, there was no obvious seasonal variation in the atmospheric HCH deposition, and the air-sea gas exchange reached equilibrium because of low HCH levels in the air and seawater after the long-term banning of HCH and the degradation. The gas exchange flux of HCH was comparable to the dry and wet deposition fluxes at the air-water interface. This suggests that the influences from the Yangtze River input and East Asian continental outflow on the fate of HCH in the YRE were limited. The gas exchange flux of DDT was about fivefold higher than the total dry and wet deposition fluxes. DDT residues in agricultural soil transported by enhanced riverine runoff were responsible for sustaining such a high net volatilization in summer. Moreover, our results indicated that there were fresh sources of DDT from the local environment to sustain net volatilization throughout the year.

  4. Temperature- and body mass-related variation in cyclic gas exchange characteristics and metabolic rate of seven weevil species: Broader implications.

    Science.gov (United States)

    Klok, C J; Chown, S L

    2005-07-01

    The influence of temperature on metabolic rate and characteristics of the gas exchange patterns of flightless, sub-Antarctic Ectemnorhinus-group species from Heard and Marion islands was investigated. All of the species showed cyclic gas exchange with no Flutter period, indicating that these species are not characterized by discontinuous gas exchange cycles. Metabolic rate estimates were substantially lower in this study than in a previous one of a subset of the species, demonstrating that open-system respirometry methods provide more representative estimates of standard metabolic rate than do many closed-system methods. We recommend that the latter, and especially constant-pressure methods, either be abandoned for estimates of standard metabolic rate in insects, or have their outputs subject to careful scrutiny, given the wide availability of the former. V(.)CO(2) increase with an increase in temperature (range: 0-15 degrees C) was modulated by an increase in cycle frequency, but typically not by an increase in burst volume. Previous investigations of temperature-related changes in cyclic gas exchange (both cyclic and discontinuous) in several other insect species were therefore substantiated. Interspecific mass-scaling of metabolic rate (ca. 0.466-0.573, excluding and including phylogenetic non-independence, respectively) produced an exponent lower than 0.75 (but not distinguishable from it or from 0.67). The increase of metabolic rate with mass was modulated by an increase in burst volume and not by a change in cycle frequency, in keeping with investigations of species showing discontinuous gas exchange. These findings are discussed in the context of the emerging macrophysiological metabolic theory of ecology.

  5. Aqueous turbulence structure immediately adjacent to the air - water interface and interfacial gas exchange

    Science.gov (United States)

    Wang, Binbin

    Air-sea interaction and the interfacial exchange of gas across the air-water interface are of great importance in coupled atmospheric-oceanic environmental systems. Aqueous turbulence structure immediately adjacent to the air-water interface is the combined result of wind, surface waves, currents and other environmental forces and plays a key role in energy budgets, gas fluxes and hence the global climate system. However, the quantification of turbulence structure sufficiently close to the air-water interface is extremely difficult. The physical relationship between interfacial gas exchange and near surface turbulence remains insufficiently investigated. This dissertation aims to measure turbulence in situ in a complex environmental forcing system on Lake Michigan and to reveal the relationship between turbulent statistics and the CO2 flux across the air-water interface. The major objective of this dissertation is to investigate the physical control of the interfacial gas exchange and to provide a universal parameterization of gas transfer velocity from environmental factors, as well as to propose a mechanistic model for the global CO2 flux that can be applied in three dimensional climate-ocean models. Firstly, this dissertation presents an advanced measurement instrument, an in situ free floating Particle Image Velocimetry (FPIV) system, designed and developed to investigate the small scale turbulence structure immediately below the air-water interface. Description of hardware components, design of the system, measurement theory, data analysis procedure and estimation of measurement error were provided. Secondly, with the FPIV system, statistics of small scale turbulence immediately below the air-water interface were investigated under a variety of environmental conditions. One dimensional wave-number spectrum and structure function sufficiently close to the water surface were examined. The vertical profiles of turbulent dissipation rate were intensively studied

  6. V02 'overshoot' during moderate-intensity exercise in endurance-trained athletes: the influence of exercise modality.

    Science.gov (United States)

    Kilding, Andrew E; Jones, Andrew M

    2008-02-01

    The purpose of this study was to investigate the influence of exercise modality on the 'overshoot' in V(O2) that has been reported following the onset of moderate-intensity (below the gas exchange threshold, GET) exercise in endurance athletes. Seven trained endurance cyclists and seven trained endurance runners completed six square-wave transitions to a work-rate or running speed requiring 80% of mode-specific GET during both cycle and treadmill running exercise. The kinetics of V(O2) was assessed using non-linear regression and any overshoot in V(O2) was quantified as the integrated volume (IV) of O(2) consumed above the steady-state requirement. During cycling, an overshoot in V(O2) was evident in all seven cyclists (IV = 136 +/- 41 ml) and in four runners (IV = 81 +/- 94 ml). During running, an overshoot in V(O2) was evident in four runners (IV = 72 +/- 61 ml) but no cyclists. These data challenge the notion that V(O2) always rises towards a steady-state with near-exponential kinetics in this exercise intensity domain. The greater incidence of the V(O2) overshoot during cycling (11/14 subjects) compared to running (4/14 subjects) indicates that the overshoot phenomenon is related to an interaction between high levels of aerobic fitness and exercise modality. We speculate that a transient loss in muscle efficiency as a consequence of a non-constant ATP requirement following the onset of constant-work-rate exercise or an initially excessive recruitment of motor units (relative to the work-rate) might contribute to the overshoot phenomenon.

  7. Numerical Investigation on the Flow and Heat Transfer Characteristics of Supercritical Liquefied Natural Gas in an Airfoil Fin Printed Circuit Heat Exchanger

    OpenAIRE

    Zhongchao Zhao; Kai Zhao; Dandan Jia; Pengpeng Jiang; Rendong Shen

    2017-01-01

    As a new kind of highly compact and efficient micro-channel heat exchanger, the printed circuit heat exchanger (PCHE) is a promising candidate satisfying the heat exchange requirements of liquefied natural gas (LNG) vaporization at low and high pressure. The effects of airfoil fin arrangement on heat transfer and flow resistance were numerically investigated using supercritical liquefied natural gas (LNG) as working fluid. The thermal properties of supercritical LNG were tested by utilizing t...

  8. Exercise tolerance in mitral stenosis and chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Uenami, Atsushi; Mizuno, Toshikazu; Chiba, Hiroshi; Ohno, Masanori; Wakino, Kouichi; Sawada, Yoshihiro; Ohno, Joichi; Kume, Kiyoshi.

    1986-01-01

    Serial radionuclide ventriculography was performed using a newly developed ''real-time'' system, and left ventricular ejection fraction (LVEF), right ventricular ejection fraction (RVEF), stroke volume (SV), and cardiac output (CO) were measured during graded supine exercise in five patients with mitral stenosis (MS), in five patients with chronic obstructive pulmonary disease (COPD) and in five healthy subjects. Simultaneous pulmonary gas exchange analysis permitted determining the anaerobic threshold, which is the point during incremental exercise when lactate begins to accumulate in the blood. LVEF at the anaerobic threshold was not significantly changed in any patient groups and in healthy subjects, but RVEF at the anaerobic threshold was lower in COPD and MS patients as compared with healthy subjects. In MS, SV during exercise was reduced at the anaerobic threshold, but not in COPD or in healthy subjects. In conclusion, reduced working capacity is related to decreased RVEF in both COPD and MS, but the inhibited increase in CO during exercise is also important for the working capacity in MS. (author)

  9. Study of plasma off-gas treatment from spent ion exchange resin pyrolysis.

    Science.gov (United States)

    Castro, Hernán Ariel; Luca, Vittorio; Bianchi, Hugo Luis

    2017-03-23

    Polystyrene divinylbenzene-based ion exchange resins are employed extensively within nuclear power plants (NPPs) and research reactors for purification and chemical control of the cooling water system. To maintain the highest possible water quality, the resins are regularly replaced as they become contaminated with a range of isotopes derived from compromised fuel elements as well as corrosion and activation products including 14 C, 60 Co, 90 Sr, 129 I, and 137 Cs. Such spent resins constitute a major proportion (in volume terms) of the solid radioactive waste generated by the nuclear industry. Several treatment and conditioning techniques have been developed with a view toward reducing the spent resin volume and generating a stable waste product suitable for long-term storage and disposal. Between them, pyrolysis emerges as an attractive option. Previous work of our group suggests that the pyrolysis treatment of the resins at low temperatures between 300 and 350 °C resulted in a stable waste product with a significant volume reduction (>50%) and characteristics suitable for long-term storage and/or disposal. However, another important issue to take into account is the complexity of the off-gas generated during the process and the different technical alternatives for its conditioning. Ongoing work addresses the characterization of the ion exchange resin treatment's off-gas. Additionally, the application of plasma technology for the treatment of the off-gas current was studied as an alternative to more conventional processes utilizing oil- or gas-fired post-combustion chambers operating at temperatures in excess of 1000 °C. A laboratory-scale flow reactor, using inductively coupled plasma, operating under sub-atmospheric conditions was developed. Fundamental experiments using model compounds have been performed, demonstrating a high destruction and removal ratio (>99.99%) for different reaction media, at low reactor temperatures and moderate power consumption

  10. Parameterization of Leaf-Level Gas Exchange for Plant Functional Groups From Amazonian Seasonal Tropical Rain Forest

    Science.gov (United States)

    Domingues, T. F.; Berry, J. A.; Ometto, J. P.; Martinelli, L. A.; Ehleringer, J. R.

    2004-12-01

    Plant communities exert strong influence over the magnitude of carbon and water cycling through ecosystems by controlling photosynthetic gas exchange and respiratory processes. Leaf-level gas exchange fluxes result from a combination of physiological properties, such as carboxylation capacity, respiration rates and hydraulic conductivity, interacting with environmental drivers such as water and light availability, leaf-to-air vapor pressure deficit, and temperature. Carbon balance models concerned with ecosystem-scale responses have as a common feature the description of eco-physiological properties of vegetation. Here we focus on the parameterization of ecophysiological gas-exchange properties of plant functional groups from a pristine Amazonian seasonally dry tropical rain forest ecosystem (FLONA-Tapajós, Santarém, PA, Brazil). The parameters were specific leaf weight, leaf nitrogen content, leaf carbon isotope ratio, maximum photosynthetic assimilation rate, photosynthetic carboxylation capacity, dark respiration rates, and stomatal conductance to water vapor. Our plant functional groupings were lianas at the top of the canopy, trees at the top of the canopy, mid-canopy trees and undestory trees. Within the functional groups, we found no evidence that leaves acclimated to seasonal changes in precipitation. However, there were life-form dependent distinctions when a combination of parameters was included. Top-canopy lianas were statistically different from top-canopy trees for leaf carbon isotope ratio, maximum photosynthetic assimilation rate, and stomatal conductance to water vapor, suggesting that lianas are more conservative in the use of water, causing a stomatal limitation on photosynthetic assimilation. Top-canopy, mid canopy and understory groupings were distinct for specific leaf weight, leaf nitrogen content, leaf carbon isotope ratio, maximum photosynthetic assimilation rate, and photosynthetic carboxylation capacity. The recognition that plant

  11. Bottom-up design of a gas futures market in East Asia: Lessons from the Dojima rice exchange

    Directory of Open Access Journals (Sweden)

    Xunpeng Shi

    2016-10-01

    Full Text Available The natural gas market in East Asia remains fragmented without a functioning benchmark price to duly reflect the dynamics of demand and supply forces in the region. A functional regional gas futures market, which is highly dependent on the presence of well-developed physical spot trading, is yet to be established. Since the intra-regional pipeline connection is largely non-existent in East Asia, it is the LNG spot cargo trading that is likely to become the basis for the regional gas futures market. This paper offers a novel approach to understanding the development of such a market by analyzing the experience of a different commodity market – the Dojima Rice Exchange (DRE – and identifying potentially transferrable lessons in the market design and the role of government regulations. Based on the case study analysis, implications for the development of natural gas trading hubs in East Asia are offered and an LNG futures exchange design is put forward.

  12. Oxygen isotope exchange between refractory inclusion in allende and solar nebula Gas

    Science.gov (United States)

    Yurimoto; Ito; Nagasawa

    1998-12-04

    A calcium-aluminum-rich inclusion (CAI) from the Allende meteorite was analyzed and found to contain melilite crystals with extreme oxygen-isotope compositions ( approximately 5 percent oxygen-16 enrichment relative to terrestrial oxygen-16). Some of the melilite is also anomalously enriched in oxygen-16 compared with oxygen isotopes measured in other CAIs. The oxygen isotopic variation measured among the minerals (melilite, spinel, and fassaite) indicates that crystallization of the CAI started from oxygen-16-rich materials that were probably liquid droplets in the solar nebula, and oxygen isotope exchange with the surrounding oxygen-16-poor nebular gas progressed through the crystallization of the CAI. Additional oxygen isotope exchange also occurred during subsequent reheating events in the solar nebula.

  13. Non-exchangeability of running vs. other exercise in their association with adiposity, and its implications for public health recommendations.

    Directory of Open Access Journals (Sweden)

    Paul T Williams

    Full Text Available Current physical activity recommendations assume that different activities can be exchanged to produce the same weight-control benefits so long as total energy expended remains the same (exchangeability premise. To this end, they recommend calculating energy expenditure as the product of the time spent performing each activity and the activity's metabolic equivalents (MET, which may be summed to achieve target levels. The validity of the exchangeability premise was assessed using data from the National Runners' Health Study.Physical activity dose was compared to body mass index (BMI and body circumferences in 33,374 runners who reported usual distance run and pace, and usual times spent running and other exercises per week. MET hours per day (METhr/d from running was computed from: a time and intensity, and b reported distance run (1.02 MET • hours per km.When computed from time and intensity, the declines (slope±SE per METhr/d were significantly greater (P<10(-15 for running than non-running exercise for BMI (slopes±SE, male: -0.12 ± 0.00 vs. 0.00±0.00; female: -0.12 ± 0.00 vs. -0.01 ± 0.01 kg/m(2 per METhr/d and waist circumference (male: -0.28 ± 0.01 vs. -0.07±0.01; female: -0. 31±0.01 vs. -0.05 ± 0.01 cm per METhr/d. Reported METhr/d of running was 38% to 43% greater when calculated from time and intensity than distance. Moreover, the declines per METhr/d run were significantly greater when estimated from reported distance for BMI (males: -0.29 ± 0.01; females: -0.27 ± 0.01 kg/m(2 per METhr/d and waist circumference (males: -0.67 ± 0.02; females: -0.69 ± 0.02 cm per METhr/d than when computed from time and intensity (cited above.The exchangeability premise was not supported for running vs. non-running exercise. Moreover, distance-based running prescriptions may provide better weight control than time-based prescriptions for running or other activities. Additional longitudinal studies and randomized clinical trials are

  14. Oxygen exchange at gas/oxide interfaces: how the apparent activation energy of the surface exchange coefficient depends on the kinetic regime.

    Science.gov (United States)

    Fielitz, Peter; Borchardt, Günter

    2016-08-10

    In the dedicated literature the oxygen surface exchange coefficient KO and the equilibrium oxygen exchange rate [Fraktur R] are considered to be directly proportional to each other regardless of the experimental circumstances. Recent experimental observations, however, contradict the consequences of this assumption. Most surprising is the finding that the apparent activation energy of KO depends dramatically on the kinetic regime in which it has been determined, i.e. surface exchange controlled vs. mixed or diffusion controlled. This work demonstrates how the diffusion boundary condition at the gas/solid interface inevitably entails a correlation between the oxygen surface exchange coefficient KO and the oxygen self-diffusion coefficient DO in the bulk ("on top" of the correlation between KO and [Fraktur R] for the pure surface exchange regime). The model can thus quantitatively explain the range of apparent activation energies measured in the different regimes: in the surface exchange regime the apparent activation energy only contains the contribution of the equilibrium exchange rate, whereas in the mixed or in the diffusion controlled regime the contribution of the oxygen self-diffusivity has also to be taken into account, which may yield significantly higher apparent activation energies and simultaneously quantifies the correlation KO ∝ DO(1/2) observed for a large number of oxides in the mixed or diffusion controlled regime, respectively.

  15. Analyzing transient closed chamber effects on canopy gas exchange for optimizing flux calculation timing

    NARCIS (Netherlands)

    Langensiepen, M.; Kupisch, M.; Wijk, van M.T.; Ewert, F.

    2012-01-01

    Transient type canopy chambers are still the only currently available practical solution for rapid screening of gas-exchange in agricultural fields. The technique has been criticized for its effect on canopy microclimate during measurement which affects the transport regime and regulation of plant

  16. Modelling non-steady-state isotope enrichment of leaf water in a gas-exchange cuvette environment.

    Science.gov (United States)

    Song, Xin; Simonin, Kevin A; Loucos, Karen E; Barbour, Margaret M

    2015-12-01

    The combined use of a gas-exchange system and laser-based isotope measurement is a tool of growing interest in plant ecophysiological studies, owing to its relevance for assessing isotopic variability in leaf water and/or transpiration under non-steady-state (NSS) conditions. However, the current Farquhar & Cernusak (F&C) NSS leaf water model, originally developed for open-field scenarios, is unsuited for use in a gas-exchange cuvette environment where isotope composition of water vapour (δv ) is intrinsically linked to that of transpiration (δE ). Here, we modified the F&C model to make it directly compatible with the δv -δE dynamic characteristic of a typical cuvette setting. The resultant new model suggests a role of 'net-flux' (rather than 'gross-flux' as suggested by the original F&C model)-based leaf water turnover rate in controlling the time constant (τ) for the approach to steady sate. The validity of the new model was subsequently confirmed in a cuvette experiment involving cotton leaves, for which we demonstrated close agreement between τ values predicted from the model and those measured from NSS variations in isotope enrichment of transpiration. Hence, we recommend that our new model be incorporated into future isotope studies involving a cuvette condition where the transpiration flux directly influences δv . There is an increasing popularity among plant ecophysiologists to use a gas-exchange system coupled to laser-based isotope measurement for investigating non-steady state (NSS) isotopic variability in leaf water (and/or transpiration); however, the current Farquhar & Cernusak (F&C) NSS leaf water model is unsuited for use in a gas-exchange cuvette environment due to its implicit assumption of isotope composition of water vapor (δv ) being constant and independent of that of transpiration (δE ). In the present study, we modified the F&C model to make it compatible with the dynamic relationship between δv and δE as is typically associated

  17. Effects of Fusarium circinatum on Disease Development and Gas Exchange in the Seedlings of Pinus spp.

    Directory of Open Access Journals (Sweden)

    Kwan-Soo Woo

    2011-08-01

    Full Text Available Four-year-old seedlings of Pinus thunbergii, Pinus densiflora and Pinus rigida were inoculated with Fusarium circinatum isolate (FT-7, the pitch canker fungus, from P. thunbergii, to evaluate the effects of the pathogen on disease development and gas exchange rate. Needle dehydration was evident on 2 of 10 seedlings of P. thunbergii and P. rigida at 18 and 21 days after inoculation, respectively, while no symptoms were observed in P. densiflora seedlings throughout the experiment. Gas exchange stopped completely in 4 of 5 measured seedlings of P. thunbergii and 2 of 5 measured seedlings of P. rigida at 25 days after inoculation, and in the remaining 3 seedlings of P. rigida at 39 days after inoculation. Disease development in P. thunbergii seedlings was faster than that in P. rigida seedlings. By the time, the experiment was ended at 78 days after inoculation, 9 of 10 seedlings of P. rigida and 8 of 10 seedlings of P. thunbergii seedlings treated with FT-7 was almost dead, but all seedlings of P. densiflora were still healthy. We suggest that P. densiflora is resistant to F. circinatum in the current study, and gas exchange rate of the species after inoculation does not differ significantly compared to that of untreated control.

  18. Comparative gas-exchange in leaves of intact and clipped, natural and planted cherrybark oak (Quercus pagoda Raf.) seedlings

    Science.gov (United States)

    Brian R. Lockhart; John D. Hodges

    2005-01-01

    Gas-exchange measurements, including C022-exchange rate (net photosynthesis), stomatal conductance, and transpiration, were conducted on intact and clipped cherrybark oak (Quercus pagoda Raf.) seedlings growing in the field and in a nursery bed. Seedlings in the field, released from midstory and understory woody competition,...

  19. [Effects of captopril on hemodynamics, gas exchange and exercise capacity in patients with pulmonary hypertension secondary to chronic obstructive pulmonary disease].

    Science.gov (United States)

    Paitl, C E; Nery, L E; Romaldini, H; Herrmann, J L; Portugal, O P; dos Santos, M L; Martinez Filho, E E

    1989-02-01

    Captopril, a potent inhibitor of angiotensin converting enzyme, was tested in patients with COPD (means forced expired volume in the first second--FEV1 = 0.73 l) and pulmonary hypertension (PAP = 41.3 mmHg). In the first phase of the experiment, patients underwent and incremental exercise test to the limit of tolerance. These were double blind, randomized, cross-over studies, where the patients received oral placebo (Pl) or captopril (Cp) 25 mg, on different days. In a second phase, the patients were submitted to hemodynamic and gasometric studies in the supine position, before placebo, the 60 min after and immediately after exercise (cycling-like leg movements). After 30 min of rest the same protocol was repeated with oral administration of 25 mg of captopril. In the metabolic evaluation (cycloergometry) captopril increased significantly exercise tolerance (means VO2-uptake at maximal exercise: CP = 0.81 vs Pl = 0.73 1/min), associated with a slower heart rate and higher O2-pulse at maximal exercise. In the hemodynamic study, when the effects of Cp and Pl were compared, the mean values of pulmonary artery pressure (PAP) and pulmonary vascular resistance (PVR) were similar at rest, but significantly lower during exercise, after captopril (means PAP Cp = 41.3 vs Pl = 51.2 mmHg; XPVR Cp = 278 vs Pl = 392 dyn. sec. cm5). There were similar systemic hemodynamic effects after Cp, but these were more intense in the pulmonary circulation (lower PVR/SVR ratio post-Cp in relation to post-Pl, during exercise). The cardiac index, systemic O2 transport and arterial and mixed venous blood gases were similar at rest and during exercise, with Pl or Cp.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Gas exchange and hydraulics in seedlings of Hevea brasiliensis during water stress and recovery.

    Science.gov (United States)

    Chen, Jun-Wen; Zhang, Qiang; Li, Xiao-Shuang; Cao, Kun-Fang

    2010-07-01

    The response of plants to drought has received significant attention, but far less attention has been given to the dynamic response of plants during recovery from drought. Photosynthetic performance and hydraulic capacity were monitored in seedlings of Hevea brasiliensis under water stress and during recovery following rewatering. Leaf water relation, gas exchange rate and hydraulic conductivity decreased gradually after water stress fell below a threshold, whereas instantaneous water use efficiency and osmolytes increased significantly. After 5 days of rewatering, leaf water relation, maximum stomatal conductance (g(s-max)) and plant hydraulic conductivity had recovered to the control levels except for sapwood area-specific hydraulic conductivity, photosynthetic assimilation rate and osmolytes. During the phase of water stress, stomata were almost completely closed before water transport efficiency decreased substantially, and moreover, the leaf hydraulic pathway was more vulnerable to water stress-induced embolism than the stem hydraulic pathway. Meanwhile, g(s-max) was linearly correlated with hydraulic capacity when water stress exceeded a threshold. In addition, a positive relationship was shown to occur between the recovery of g(s-max) and of hydraulic capacity during the phase of rewatering. Our results suggest (i) that stomatal closure effectively reduces the risk of xylem dysfunction in water-stressed plants at the cost of gas exchange, (ii) that the leaf functions as a safety valve to protect the hydraulic pathway from water stress-induced dysfunction to a larger extent than does the stem and (iii) that the full drought recovery of gas exchange is restricted by not only hydraulic factors but also non-hydraulic factors.

  1. Fluoroplastic materials for pressure tubes in flue gas heat exchangers under corrosive conditions of flue gas desulfurisation plants; Fluorkunststoffe fuer Druckrohre in Rauchgaswaermetauschern unter korrosiven Bedingungen fuer die Rauchgasentschwefelung

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk-Gaudig, Gabriele [Dyneon GmbH, Burgkirchen (Germany); Broda, Siegfried [Heatec Co., Ltd., Chonburi (Thailand); Adamczyk, Frank; Kreilos, Klaus [Babcock Borsig Service GmbH, Oberhausen (Germany). Bereich Waermenutzung

    2010-07-01

    Since the 1980s, power plants have been required to have flue gas desulphurising plants. For the cooling of flue gases to below the acid dew point and subsequent reheating, corrosion-resistant gas-gas heat exchanger systems had already been developed at this time by what is now Babcock Borsig Service GmbH (BBS). The best results were achieved using 100 % plastic piping as a vital component. In addition to the development of the plastic heat exchangers and the differences in design relative to alternative models, the various types of fluoroplastics will be discussed, and in particular the difference between PFA and PTFE. (orig.)

  2. Spill exercise 1980: an LLNL emergency training exercise

    International Nuclear Information System (INIS)

    Morse, J.L.; Gibson, T.A.; Vance, W.F.

    1981-01-01

    An emergency training exercise at Lawrence Livermore National Laboratory (LLNL) demonstrated that off-hours emergency personnel can respond promptly and effecively to an emergency situation involving radiation, hazardous chemicals, and injured persons. The exercise simulated an explosion in a chemistry laboratory and a subsequent toxic-gas release

  3. Modeling the effects of temperature and relative humidity on gas exchange of prickly pear cactus (Opuntia spp.) stems

    NARCIS (Netherlands)

    Guevara-Arauza, J.C.; Yahia, E.M.; Cedeno, L.; Tijskens, L.M.M.

    2006-01-01

    A model to estimate gas profile of modified atmosphere packaged (MAP) prickly pear cactus stems was developed and calibrated. The model describes the transient gas exchange taking in consideration the effect of temperature (T) and relative humidity (RH) on film permeability (FPgas), respiration rate

  4. Surviving floods: leaf gas films improve O₂ and CO₂ exchange, root aeration, and growth of completely submerged rice.

    Science.gov (United States)

    Pedersen, Ole; Rich, Sarah Meghan; Colmer, Timothy David

    2009-04-01

    When completely submerged, the leaves of some species retain a surface gas film. Leaf gas films on submerged plants have recently been termed 'plant plastrons', analogous with the plastrons of aquatic insects. In aquatic insects, surface gas layers (i.e. plastrons) enlarge the gas-water interface to promote O₂ uptake when under water; however, the function of leaf gas films has rarely been considered. The present study demonstrates that gas films on leaves of completely submerged rice facilitate entry of O₂ from floodwaters when in darkness and CO₂ entry when in light. O₂ microprofiles showed that the improved gas exchange was not caused by differences in diffusive boundary layers adjacent to submerged leaves with or without gas films; instead, reduced resistance to gas exchange was probably due to the enlarged water-gas interface (cf. aquatic insects). When gas films were removed artificially, underwater net photosynthesis declined to only 20% of the rate with gas films present, such that, after 7 days of complete submergence, tissue sugar levels declined, and both shoot and root growth were reduced. Internal aeration of roots in anoxic medium, when shoots were in aerobic floodwater in darkness or when in light, was improved considerably when leaf gas films were present. Thus, leaf gas films contribute to the submergence tolerance of rice, in addition to those traits already recognized, such as the shoot-elongation response, aerenchyma and metabolic adjustments to O₂ deficiency and oxidative stress. © 2009 The Authors. Journal compilation © 2009 Blackwell Publishing Ltd.

  5. Effects of High-Intensity Interval Exercise versus Moderate Continuous Exercise on Glucose Homeostasis and Hormone Response in Patients with Type 1 Diabetes Mellitus Using Novel Ultra-Long-Acting Insulin.

    Science.gov (United States)

    Moser, Othmar; Tschakert, Gerhard; Mueller, Alexander; Groeschl, Werner; Pieber, Thomas R; Obermayer-Pietsch, Barbara; Koehler, Gerd; Hofmann, Peter

    2015-01-01

    We investigated blood glucose (BG) and hormone response to aerobic high-intensity interval exercise (HIIE) and moderate continuous exercise (CON) matched for mean load and duration in type 1 diabetes mellitus (T1DM). Seven trained male subjects with T1DM performed a maximal incremental exercise test and HIIE and CON at 3 different mean intensities below (A) and above (B) the first lactate turn point and below the second lactate turn point (C) on a cycle ergometer. Subjects were adjusted to ultra-long-acting insulin Degludec (Tresiba/ Novo Nordisk, Denmark). Before exercise, standardized meals were administered, and short-acting insulin dose was reduced by 25% (A), 50% (B), and 75% (C) dependent on mean exercise intensity. During exercise, BG, adrenaline, noradrenaline, dopamine, cortisol, glucagon, and insulin-like growth factor-1, blood lactate, heart rate, and gas exchange variables were measured. For 24 h after exercise, interstitial glucose was measured by continuous glucose monitoring system. BG decrease during HIIE was significantly smaller for B (p = 0.024) and tended to be smaller for A and C compared to CON. No differences were found for post-exercise interstitial glucose, acute hormone response, and carbohydrate utilization between HIIE and CON for A, B, and C. In HIIE, blood lactate for A (p = 0.006) and B (p = 0.004) and respiratory exchange ratio for A (p = 0.003) and B (p = 0.003) were significantly higher compared to CON but not for C. Hypoglycemia did not occur during or after HIIE and CON when using ultra-long-acting insulin and applying our methodological approach for exercise prescription. HIIE led to a smaller BG decrease compared to CON, although both exercises modes were matched for mean load and duration, even despite markedly higher peak workloads applied in HIIE. Therefore, HIIE and CON could be safely performed in T1DM. ClinicalTrials.gov NCT02075567 http://www.clinicaltrials.gov/ct2/show/NCT02075567.

  6. Effects of High-Intensity Interval Exercise versus Moderate Continuous Exercise on Glucose Homeostasis and Hormone Response in Patients with Type 1 Diabetes Mellitus Using Novel Ultra-Long-Acting Insulin.

    Directory of Open Access Journals (Sweden)

    Othmar Moser

    Full Text Available We investigated blood glucose (BG and hormone response to aerobic high-intensity interval exercise (HIIE and moderate continuous exercise (CON matched for mean load and duration in type 1 diabetes mellitus (T1DM.Seven trained male subjects with T1DM performed a maximal incremental exercise test and HIIE and CON at 3 different mean intensities below (A and above (B the first lactate turn point and below the second lactate turn point (C on a cycle ergometer. Subjects were adjusted to ultra-long-acting insulin Degludec (Tresiba/ Novo Nordisk, Denmark. Before exercise, standardized meals were administered, and short-acting insulin dose was reduced by 25% (A, 50% (B, and 75% (C dependent on mean exercise intensity. During exercise, BG, adrenaline, noradrenaline, dopamine, cortisol, glucagon, and insulin-like growth factor-1, blood lactate, heart rate, and gas exchange variables were measured. For 24 h after exercise, interstitial glucose was measured by continuous glucose monitoring system.BG decrease during HIIE was significantly smaller for B (p = 0.024 and tended to be smaller for A and C compared to CON. No differences were found for post-exercise interstitial glucose, acute hormone response, and carbohydrate utilization between HIIE and CON for A, B, and C. In HIIE, blood lactate for A (p = 0.006 and B (p = 0.004 and respiratory exchange ratio for A (p = 0.003 and B (p = 0.003 were significantly higher compared to CON but not for C.Hypoglycemia did not occur during or after HIIE and CON when using ultra-long-acting insulin and applying our methodological approach for exercise prescription. HIIE led to a smaller BG decrease compared to CON, although both exercises modes were matched for mean load and duration, even despite markedly higher peak workloads applied in HIIE. Therefore, HIIE and CON could be safely performed in T1DM.ClinicalTrials.gov NCT02075567 http://www.clinicaltrials.gov/ct2/show/NCT02075567.

  7. Evaluation of off-gas characteristics in vitrification process of ion-exchange resin

    International Nuclear Information System (INIS)

    Park, S. C.; Kim, H. S.; Yang, K. H.; Yun, C. H.; Hwang, T. W.; Shin, S. W.

    2001-01-01

    The properties of off-gas generated from vitrification process of ion-exchange resin were characterized. Theoretical composition and flow rate of the off-gas were calculated based on chemical composition of resin and it's burning condition inside CCM. The calculated off-gas flow rate was 67.9 Nm 3 /h at the burning rate of 40 kg/h. And the composition of off-gas was evaluated as CO 2 (41.4%), Steam (40.0%), O 2 (13.3%), NO (3.6%), and SO 2 (1.6%) in order. Then, actual flow rate and composition of off-gas were measured during pilot-scale demonstration tests and the results were compared with theoretical values. The actual flow rate of off-gas was about 1.6 times higher than theoretical one. The difference between theoretical and actual flow rates was caused by the in-leakage of air to the system, and the in-leakage rate was evaluated as 36.3 Nm 3 /h. Because of continuous change in the combustion parameters inside CCM, during demonstration tests, the concentration of toxic gases showed wide fluctuation. However, the concentration of CO, a barometer of incompleteness of combustion inside CCM, was stabilized soon. The result showed quasi-equilibrium state was achieved two hours after feeding of resin. (author)

  8. The General Adaptation Syndrome: Potential misapplications to resistance exercise.

    Science.gov (United States)

    Buckner, Samuel L; Mouser, J Grant; Dankel, Scott J; Jessee, Matthew B; Mattocks, Kevin T; Loenneke, Jeremy P

    2017-11-01

    Within the resistance training literature, one of the most commonly cited tenets with respect to exercise programming is the "General Adaptation Syndrome" (GAS). The GAS is cited as a central theory behind the periodization of resistance exercise. However, after examining the original stress research by Hans Selye, the applications of GAS to resistance exercise may not be appropriate. To examine the original work of Hans Selye, as well as the original papers through which the GAS was established as a central theory for periodized resistance exercise. We conducted a review of Selye's work on the GAS, as well as the foundational papers through which this concept was applied to resistance exercise. The work of Hans Selye focused on the universal physiological stress responses noted upon exposure to toxic levels of a variety of pharmacological agents and stimuli. The extrapolations that have been made to resistance exercise appear loosely based on this concept and may not be an appropriate basis for application of the GAS to resistance exercise. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. The hydraulic conductance of Fraxinus ornus leaves is constrained by soil water availability and coordinated with gas exchange rates.

    Science.gov (United States)

    Gortan, Emmanuelle; Nardini, Andrea; Gascó, Antonio; Salleo, Sebastiano

    2009-04-01

    Leaf hydraulic conductance (Kleaf) is known to be an important determinant of plant gas exchange and photosynthesis. Little is known about the long-term impact of different environmental factors on the hydraulic construction of leaves and its eventual consequences on leaf gas exchange. In this study, we investigate the impact of soil water availability on Kleaf of Fraxinus ornus L. as well as the influence of Kleaf on gas exchange rates and plant water status. With this aim, Kleaf, leaf conductance to water vapour (gL), leaf water potential (Psileaf) and leaf mass per area (LMA) were measured in F. ornus trees, growing in 21 different sites with contrasting water availability. Plants growing in arid sites had lower Kleaf, gL and Psileaf than those growing in sites with higher water availability. On the contrary, LMA was similar in the two groups. The Kleaf values recorded in sites with two different levels of soil water availability were constantly different from each other regardless of the amount of precipitation recorded over 20 days before measurements. Moreover, Kleaf was correlated with gL values. Our data suggest that down-regulation of Kleaf is a component of adaptation of plants to drought-prone habitats. Low Kleaf implies reduced gas exchange which may, in turn, influence the climatic conditions on a local/regional scale. It is concluded that leaf hydraulics and its changes in response to resource availability should receive greater attention in studies aimed at modelling biosphere-atmosphere interactions.

  10. Predicting liquid water saturation through differently structured cathode gas diffusion media of a proton exchange Membrane Fuel Cell

    NARCIS (Netherlands)

    Akhtar, N.; Kerkhof, P.J.A.M.

    2012-01-01

    The role of gas diffusion media with differently structured properties have been examined with emphasis on the liquid water saturation within the cathode of a proton exchange membrane fuel cell (PEMFC). The cathode electrode consists of a gas diffusion layer (GDL), a micro-porous layer and a

  11. Effect of hormone replacement on exercise cardiopulmonary reserve and recovery performance in subclinical hypothyroidism

    Directory of Open Access Journals (Sweden)

    M.R.M. Mainenti

    2010-11-01

    Full Text Available Subclinical hypothyroidism (SH patients present cardiopulmonary, vascular and muscle dysfunction, but there is no consensus about the benefits of levothyroxine (L-T4 intervention on cardiopulmonary performance during exercise. The aim of the present study was to investigate the effects of L-T4 on cardiopulmonary exercise reserve and recovery in SH patients. Twenty-three SH women, 44 (40-50 years old, were submitted to two ergospirometry tests, with an interval of 6 months of normalization of thyroid-stimulating hormone (TSH levels (L-T4 replacement group or simple observation (TSH = 6.90 μIU/mL; L-T4 = 1.02 ng/dL. Patients with TSH >10 μIU/mL were excluded from the study to assure that they would receive treatment in this later stage of SH. Twenty 30- to 57-year-old women with no thyroid dysfunction (TSH = 1.38 μIU/mL; L-T4 = 1.18 ng/dL were also evaluated. At baseline, lower values of gas exchange ratio reserve (0.24 vs 0.30; P < 0.05 were found for SH patients. The treated group presented greater variation than the untreated group for pulmonary ventilation reserve (20.45 to 21.60 L/min; median variation = 5.2 vs 25.09 to 22.45 L/min; median variation = -4.75, respectively and for gas exchange ratio reserve (0.19 to 0.27; median variation = 0.06 vs 0.28 to 0.18; median variation = -0.08, respectively. There were no relevant differences in cardiopulmonary recovery for either group at baseline or after follow-up. In the sample studied, L-T4 replacement improved exercise cardiopulmonary reserve, but no modification was found in recovery performance after exercise during this period of analysis.

  12. Microsoft Exchange 2013 cookbook

    CERN Document Server

    Van Horenbeeck, Michael

    2013-01-01

    This book is a practical, hands-on guide that provides the reader with a number of clear, step-by-step exercises.""Microsoft Exchange 2013 Cookbook"" is targeted at network administrators who deal with the Exchange server in their day-to-day jobs. It assumes you have some practical experience with previous versions of Exchange (although this is not a requirement), without being a subject matter expert.

  13. Effect of furosemide on pulmonary blood flow distribution in resting and exercising horses

    Science.gov (United States)

    Erickson, H. H.; Bernard, S. L.; Glenny, R. W.; Fedde, M. R.; Polissar, N. L.; Basaraba, R. J.; Walther, S. M.; Gaughan, E. M.; McMurphy, R.; Hlastala, M. P.

    1999-01-01

    We determined the spatial distribution of pulmonary blood flow (PBF) with 15-micron fluorescent-labeled microspheres during rest and exercise in five Thoroughbred horses before and 4 h after furosemide administration (0.5 mg/kg iv). The primary finding of this study was that PBF redistribution occurred from rest to exercise, both with and without furosemide. However, there was less blood flow to the dorsal portion of the lung during exercise postfurosemide compared with prefurosemide. Furosemide did alter the resting perfusion distribution by increasing the flow to the ventral regions of the lung; however, that increase in flow was abated with exercise. Other findings included 1) unchanged gas exchange and cardiac output during rest and exercise after vs. before furosemide, 2) a decrease in pulmonary arterial pressure after furosemide, 3) an increase in the slope of the relationship of PBF vs. vertical height up the lung during exercise, both with and without furosemide, and 4) a decrease in blood flow to the dorsal region of the lung at rest after furosemide. Pulmonary perfusion variability within the lung may be a function of the anatomy of the pulmonary vessels that results in a predominantly fixed spatial pattern of flow distribution.

  14. Gas exchange recovery following natural drought is rapid unless limited by loss of leaf hydraulic conductance: evidence from an evergreen woodland.

    Science.gov (United States)

    Skelton, Robert P; Brodribb, Timothy J; McAdam, Scott A M; Mitchell, Patrick J

    2017-09-01

    Drought can cause major damage to plant communities, but species damage thresholds and postdrought recovery of forest productivity are not yet predictable. We used an El Niño drought event as a natural experiment to test whether postdrought recovery of gas exchange could be predicted by properties of the water transport system, or if metabolism, primarily high abscisic acid concentration, might delay recovery. We monitored detailed physiological responses, including shoot sapflow, leaf gas exchange, leaf water potential and foliar abscisic acid (ABA), during drought and through the subsequent rehydration period for a sample of eight canopy and understory species. Severe drought caused major declines in leaf water potential, elevated foliar ABA concentrations and reduced stomatal conductance and assimilation rates in our eight sample species. Leaf water potential surpassed levels associated with incipient loss of leaf hydraulic conductance in four species. Following heavy rainfall gas exchange in all species, except those trees predicted to have suffered hydraulic impairment, recovered to prestressed rates within 1 d. Recovery of plant gas exchange was rapid and could be predicted by the hydraulic safety margin, providing strong support for leaf vulnerability to water deficit as an index of damage under natural drought conditions. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  15. In-vitro evaluation of limitations and possibilities for the future use of intracorporeal gas exchangers placed in the upper lobe position.

    Science.gov (United States)

    Schumer, Erin; Höffler, Klaus; Kuehn, Christian; Slaughter, Mark; Haverich, Axel; Wiegmann, Bettina

    2018-03-01

    The lack of donor organs has led to the development of alternative "destination therapies", such as a bio-artificial lung (BA) for end-stage lung disease. Ultimately aiming at a fully implantable BA, general capabilities and limitations of different oxygenators were tested based on the model of BA positioning at the right upper lobe. Three different-sized oxygenators (neonatal, paediatric, and adult) were tested in a mock circulation loop regarding oxygenation and decarboxylation capacities for three respiratory pathologies. Blood flows were imitated by a roller pump, and respiration was imitated by a mechanical ventilator with different FiO 2 applications. Pressure drops across the oxygenators and the integrity of the gas-exchange hollow fibers were analyzed. The neonatal oxygenator proved to be insufficient regarding oxygenation and decarboxylation. Despite elevated pCO 2 levels, the paediatric and adult oxygenators delivered comparable sufficient oxygen levels, but sufficient decarboxylation across the oxygenators was ensured only at flow rates of 0.5 L min. Only the adult oxygenator indicated no significant pressure drops. For all tested conditions, gas-exchange hollow fibers remained intact. This is the first study showing the general feasibility of delivering sufficient levels of gas exchange to an intracorporeal BA via patient's breathing, without damaging gas-exchange hollow fiber membranes.

  16. Comparison of extracapillary and endocapillary blood flow oxygenators for open heart surgery in dogs: efficiency of gas exchange and platelet conservation.

    Science.gov (United States)

    Hoshi, Katsuichiro; Tanaka, Ryou; Shibazaki, Akira; Nagashima, Yukiko; Hirao, Hidehiro; Namiki, Ryosuke; Takashima, Kazuaki; Noishiki, Yasuharu; Yamane, Yoshihisa

    2003-03-01

    The goal of the current study was to compare the efficiency of gas exchange and platelet conservation of a new extracapillary blood flow oxygenator versus an endocapillary blood flow oxygenator during open heart surgery with extracorporeal circulation in dogs. Dilation and remodeling of the right ventricular outflow tract of dogs was performed using a patch graft technique to simulate pulmonary stenosis. Sequential pre- and post-operative blood analysis revealed that gas exchange efficiency and platelet conservation was significantly greater with the extracapillary blood flow oxygenator than with the endocapillary blood flow oxygenator. However, the priming volume of the extracapillary blood flow oxygenator was significantly greater, leading to hemodilution. We conclude that while the extracapillary blood flow oxygenator provided benefits in terms of gas exchange and platelet conservation, development of a smaller extracapillary blood flow type oxygenator to reduce hemodilution effects would be beneficial.

  17. GROWTH, GAS EXCHANGE AND YIELD OF CORN WHEN FERTIGATED WITH BOVINE BIOFERTILIZER

    OpenAIRE

    THALES VINÍCIUS DE ARAÚJO VIANA; JOÃO GUILHERME ARAÚJO LIMA; GEOCLEBER GOMES DE SOUSA; LUIS GONZAGA PINHEIRO NETO; BENITO MOREIRA DE AZEVEDO

    2014-01-01

    The bovine biofertilizer applied through irrigation water in the soil (bio fertigation), can be a viable organic source to maintain fertility levels in agricultural production systems. So, this work was aimed at evaluating the effects of different concentrations of bovine biofertilizer applied by fertigation on corn growth, gas exchange and yield. The experiment was conducted under full sun exposure, in Fortaleza, Ceara, in 100 liter (100 L) vessels. The experimental design was that of random...

  18. Laparoscopic cholecystectomy using abdominal wall retraction. Hemodynamics and gas exchange, a comparison with conventional pneumoperitoneum

    NARCIS (Netherlands)

    Meijer, D. W.; Rademaker, B. P.; Schlooz, S.; Bemelman, W. A.; de Wit, L. T.; Bannenberg, J. J.; Stijnen, T.; Gouma, D. F.

    1997-01-01

    BACKGROUND: Disadvantages related to CO2 pneumoperitoneum have led to development of the abdominal wall retractor (AWR), a device designed to facilitate laparoscopic surgery without conventional pneumoperitoneum (15 mmHg CO2). We investigated the effects of the AWR on hemodynamics and gas exchange

  19. Experimental studies on hydrogen isotopic deuterium from gas to liquid phase by catalytic exchange

    International Nuclear Information System (INIS)

    Luo Yangming; Wang Heyi; Liu Jun; Fu Zhonghua; Wang Changbin; Han Jun; Xia Xiulong; Tang Lei

    2005-01-01

    The experimental studies on hydrogen isotopic deuterium from gas to liquid phase were completed by mixed ratio 1:4 of Pt-SDB hydrophobic catalyst and hydrophilic packing. The influencing factors on number of transfer units (NTU) and transformation efficiencies of deuterium were researched. The results show that preferable NTU can be obtained by choosing suitable operational temperature and flux of exchange gas. The transformation rate increases with increasing liquid flux, but it cannot obviously be improved when liquid flux attains some level. The length of catalytic column has an obvious influence on transformation rate and 90% of transformation rate is obtained by 4 m column length at gas flux with 2 m 3 /h, liquid flux with 1-2 kg/h and 45 degree C. (author)

  20. The effect of additional dead space on respiratory exchange ratio and carbon dioxide production due to training.

    Science.gov (United States)

    Smolka, Lukasz; Borkowski, Jacek; Zaton, Marek

    2014-01-01

    The purpose of the study was to investigate the effects of implementing additional respiratory dead space during cycloergometry-based aerobic training. The primary outcome measures were respiratory exchange ratio (RER) and carbon dioxide production (VCO2). Two groups of young healthy males: Experimental (Exp, n = 15) and Control (Con, n = 15), participated in this study. The training consisted of 12 sessions, performed twice a week for 6 weeks. A single training session consisted of continuous, constant-rate exercise on a cycle ergometer at 60% of VO2max which was maintained for 30 minutes. Subjects in Exp group were breathing through additional respiratory dead space (1200ml), while subjects in Con group were breathing without additional dead space. Pre-test and two post-training incremental exercise tests were performed for the detection of gas exchange variables. In all training sessions, pCO2 was higher and blood pH was lower in the Exp group (p exchange ratio and carbon dioxide production.In all training sessions, respiratory acidosis was gained by experimental group only.No significant difference in RER and VCO2 between experimental and control group due to the trainings.The lack of difference in post-training values of RER and VCO2 between groups means absence of inhibition in glycolysis and glycogenolysis during exercise with additional dead space.

  1. [Effects of different water potentials on leaf gas exchange and chlorophyll fluorescence parameters of cucumber during post-flowering growth stage].

    Science.gov (United States)

    Lin, Lu; Tang, Yun; Zhang, Ji-tao; Yan, Wan-li; Xiao, Jian-hong; Ding, Chao; Dong, Chuan; Ji, Zeng-shun

    2015-07-01

    Impacts of different substrate water potentials (SWP) on leaf gas exchange and chlorophyll fluorescence parameters of greenhouse cucumber during its post-flowering growth stage were analyzed in this study. The results demonstrated that -10 and -30 kPa were the critical values for initiating stomatal and non-stomatal limitation of drought stress, respectively. During the stage of no drought stress (-10 kPa gas exchange parameters and chlorophyll fluorescence parameters were not different significantly among treatments. During the stage of stomatal limitation of drought stress (-30 kPawater use efficiency (WUEi) and non-photochemical quenching (qN) increased. In this stage, gas exchange parameters changed faster than chlorophyll fluorescence parameters and differed significantly among treatments. During the stage of non-stomatal limitation of drought stress (-45 kPa≤SWP ≤ -30 kPa), with the decrease of SWP, light saturation point (LSP), Rd, CE, Vcmax, VTPU, LS, WUEi, ΦpPSII, Fv/Fm and qp decreased, while CCP, Ci and qN increased. In this stage, chlorophyll fluorescence parameters changed faster than gas exchange parameters and differed significantly among treatments. In production of greenhouse cucumber, -10 and -5 kPa should be the lower and upper limit value of irrigation, respectively. The stomatal limitation of drought stress could be relieved by irrigation before SWP decreased to -30 kPa. While, the non-stomatal injury of drought stress would be unrecoverable once SWP decreased to lower than -30 kPa.

  2. Gas exchange rates measured using a dual-tracer (SF6 and3he) method in the coastal waters of Korea

    Science.gov (United States)

    Lee, Hyun-Woo; Lee, Kitack; Kaown, Duk-In

    2008-03-01

    Over a period of 5 days between August 12 and 17, 2005, we performed a gas exchange experiment using the dual tracer method in a tidal coastal ocean located off the southern coast of Korea. The gas exchange rate was determined from temporal changes in the ratio of3He to SF6 measured daily in the surface mixed layer. The measured gas exchange rate ( k CO 2), normalized to a Schmidt number of 600 for CO2 in fresh water at 20°C, was approximately 5.0 cm h-1 at a mean wind speed of 3.9 m s-1 during the study period. This value is significantly less than those obtained from floating chamber-based experiments performed previously in estuarine environments, but is similar in magnitude to values obtained using the dual tracer method in river and tidal coastal waters and values predicted on the basis of the relationship between the gas exchange rate and wind speed (Wanninkhof 1992), which is generally applicable to the open ocean. Our result is also consistent with the relationship of Raymond and Cole (2001), which was derived from experiments carried out in estuarine environments using222Rn and chlorofluorocarbons along with measurements undertaken in the Hudson River, Canada, using SF6 and3He. Our results indicate that tidal action in a microtidal region did not discernibly enhance the measured k CO 2 value.

  3. Extracorporeal gas exchange with the DeltaStream rotary blood pump in experimental lung injury.

    Science.gov (United States)

    Dembinski, Rolf; Kopp, Rüdger; Henzler, Dietrich; Hochhausen, Nadine; Oslender, Nicole; Max, Martin; Rossaint, Rolf; Kuhlen, Ralf

    2003-06-01

    In most severe cases of the acute respiratory distress syndrome, veno-venous extracorporeal membrane oxygenation (ECMO) can be used to facilitate gas exchange. However, the clinical use is limited due to the size and the concomitant risk of severe adverse events of conventionally-used centrifugal blood pumps with high extracorporeal blood volumes. The DeltaStream blood pump is a small-sized rotary blood pump that may reduce extracorporeal blood volume, foreign surfaces, contact activation of the coagulation system, and blood trauma. The aim of the present study was to test the safety and efficacy of the DeltaStream pump for ECMO in animals with normal lung function and experimental acute lung injury (ALI). Therefore, veno-venous ECMO was performed for 6 hours in mechanically ventilated pigs with normal lung function (n=6) and with ALI induced by repeated lung lavage (n=6) with a blood flow of 30% of the cardiac output. Gas flow with a FiO2 of 1.0 was set to equal blood flow. With a mean activated clotting time of 121 +/- 22 s, no circulatory impairment or thrombus formation was revealed during ECMO. Furthermore, free plasma Hb did not increase. In controls, hemodynamics and gas exchange remained unchanged. In animals with ALI, hemodynamics remained stable and gas transfer across the extracorporeal oxygenators was optimal, but only in 2 animals was a marked increase in PaO2 observed. CO2 removal was efficacious in all animals. We concluded that the DeltaStream blood pump may be used for veno-venous ECMO without major blood damage or hemodynamic impairment.

  4. Differential Effects of Endotracheal Suctioning on Gas Exchanges in Patients with Acute Respiratory Failure under Pressure-Controlled and Volume-Controlled Ventilation

    Directory of Open Access Journals (Sweden)

    Xiao-Wei Liu

    2015-01-01

    Full Text Available This study was conducted to evaluate the effects of open endotracheal suctioning on gas exchange and respiratory mechanics in ARF patients under the modes of PCV or VCV. Ninety-six ARF patients were treated with open endotracheal suctioning and their variations in respiratory mechanics and gas exchange after the suctions were compared. Under PCV mode, compared with the initial level of tidal volume (VT, ARF patients showed 30.0% and 27.8% decrease at 1 min and 10 min, respectively. Furthermore, the initial respiratory system compliance (Crs decreased by 29.6% and 28.5% at 1 min and 10 min, respectively. Under VCV mode, compared with the initial level, 38.6% and 37.5% increase in peak airway pressure (PAP were found at 1 min and 10 min, respectively. Under PCV mode, the initial PaO2 increased by 6.4% and 10.2 % at 3 min and 10 min, respectively, while 18.9% and 30.6% increase of the initial PaO2 were observed under VCV mode. Summarily, endotracheal suctioning may impair gas exchange and decrease lung compliance in ARF patients receiving mechanical ventilation under both PCV and VCV modes, but endotracheal suctioning effects on gas exchange were more severe and longer-lasting under PCV mode than VCV.

  5. Exchange between the stagnant and flowing zone in gas-flowing solids-fixed bed contactors

    Directory of Open Access Journals (Sweden)

    ALEKSANDAR P. DUDUKOVIC

    2005-02-01

    Full Text Available In countercurrent gas – flowing solids – fixed bed contactors, a fraction of the flowing solids is in motion (dynamic holdup, while the other fraction is resting on the fixed bed elements. In this study it was experimentally proved that the stagnant zone should not be considered as a dead part of the column, but that there is a dynamic exchange between these two portions of flowing solids particles. Combining a mathematical model with tracer experiments, the rate of exchange was determined and it was shown that only a small part (ca. 20 % of the stagnant region should be considered as a dead one.

  6. Alveolar­–capillary reserve during exercise in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Behnia M

    2017-10-01

    (range: 0.8–4.8. Ventilatory efficiency plateaued at 37±5 during exercise, partial pressure of mix expired CO2/partial pressure of end tidal CO2 ratio ranged from 0.63 to 0.67, while a noninvasive index of pulmonary capacitance, O2 pulse × PetCO2 (GxCap rose to 138%. The exercise IBDLCO/Qc ratio was related to O2 pulse (VO2/HR, r=0.58, p<0.01, and subjects with the highest exercise IBDLCO/Qc ratio or the greatest rise from rest had the highest peak VO2 values (r=0.65 and 0.51, respectively, p<0.05. Of the noninvasive gas exchange measures of pulmonary vascular function, GxCap was most closely associated with DLCO, DLCO/Qc, and VO2 peak.Conclusion: COPD patients who can expand gas exchange surface area as assessed with DLCO during exercise relative to pulmonary blood flow have a more preserved exercise capacity. Keywords: airflow limitation, exercise intolerance, lung gas transfer, dyspnea, COPD, diffusion capacity, cardiopulmonary exercise testing

  7. Two Inexpensive and Non-destructive Techniques to Correct for Smaller-Than-Gasket Leaf Area in Gas Exchange Measurements

    Directory of Open Access Journals (Sweden)

    Andreas M. Savvides

    2018-04-01

    Full Text Available The development of technology, like the widely-used off-the-shelf portable photosynthesis systems, for the quantification of leaf gas exchange rates and chlorophyll fluorescence offered photosynthesis research a massive boost. Gas exchange parameters in such photosynthesis systems are calculated as gas exchange rates per unit leaf area. In small chambers (<10 cm2, the leaf area used by the system for these calculations is actually the internal gasket area (AG, provided that the leaf covers the entire AG. In this study, we present two inexpensive and non-destructive techniques that can be used to easily quantify the enclosed leaf area (AL of plant species with leaves of surface area much smaller than the AG, such as that of cereal crops. The AL of the cereal crop species studied has been measured using a standard image-based approach (iAL and estimated using a leaf width-based approach (wAL. iAL and wAL did not show any significant differences between them in maize, barley, hard and soft wheat. Similar results were obtained when the wAL was tested in comparison with iAL in different positions along the leaf in all species studied. The quantification of AL and the subsequent correction of leaf gas exchange parameters for AL provided a precise quantification of net photosynthesis and stomatal conductance especially with decreasing AL. This study provides two practical, inexpensive and non-destructive solutions to researchers dealing with photosynthesis measurements on small-leaf plant species. The image-based technique can be widely used for quantifying AL in many plant species despite their leaf shape. The leaf width-based technique can be securely used for quantifying AL in cereal crop species such as maize, wheat and barley along the leaf. Both techniques can be used for a wide range of gasket shapes and sizes with minor technique-specific adjustments.

  8. Gas exchange in the Pee Dee River based on 222Rn evasion

    International Nuclear Information System (INIS)

    Moore, W.S.; Elsinger, R.J.

    1983-01-01

    Excess 222 Rn concentrations decrease downstream in the fresh water section of the Pee Dee River. Ground water is the primary source of the excess 222 Rn to the River. Using the radon concentration gradients determined during four sampling periods, gas exchange rates based on the stagnant film model are calculated. Stagnant film thicknesses range from 19 μm to 48 μm and mass transfer coefficients range from 2.1 m/d to 4.1 m/d

  9. Dynamics of leaf gas exchange, xylem and phloem transport, water potential and carbohydrate concentration in a realistic 3-D model tree crown.

    Science.gov (United States)

    Nikinmaa, Eero; Sievänen, Risto; Hölttä, Teemu

    2014-09-01

    Tree models simulate productivity using general gas exchange responses and structural relationships, but they rarely check whether leaf gas exchange and resulting water and assimilate transport and driving pressure gradients remain within acceptable physical boundaries. This study presents an implementation of the cohesion-tension theory of xylem transport and the Münch hypothesis of phloem transport in a realistic 3-D tree structure and assesses the gas exchange and transport dynamics. A mechanistic model of xylem and phloem transport was used, together with a tested leaf assimilation and transpiration model in a realistic tree architecture to simulate leaf gas exchange and water and carbohydrate transport within an 8-year-old Scots pine tree. The model solved the dynamics of the amounts of water and sucrose solute in the xylem, cambium and phloem using a fine-grained mesh with a system of coupled ordinary differential equations. The simulations predicted the observed patterns of pressure gradients and sugar concentration. Diurnal variation of environmental conditions influenced tree-level gradients in turgor pressure and sugar concentration, which are important drivers of carbon allocation. The results and between-shoot variation were sensitive to structural and functional parameters such as tree-level scaling of conduit size and phloem unloading. Linking whole-tree-level water and assimilate transport, gas exchange and sink activity opens a new avenue for plant studies, as features that are difficult to measure can be studied dynamically with the model. Tree-level responses to local and external conditions can be tested, thus making the approach described here a good test-bench for studies of whole-tree physiology.

  10. Effect of PEEP and inhaled nitric oxide on pulmonary gas exchange during gaseous and partial liquid ventilation with small volumes of perfluorocarbon.

    Science.gov (United States)

    Max, M; Kuhlen, R; Falter, F; Reyle-Hahn, M; Dembinski, R; Rossaint, R

    2000-04-01

    Partial liquid ventilation, positive end-expiratory pressure (PEEP) and inhaled nitric oxide (NO) can improve ventilation/perfusion mismatch in acute lung injury (ALI). The aim of the present study was to compare gas exchange and hemodynamics in experimental ALI during gaseous and partial liquid ventilation at two different levels of PEEP, with and without the inhalation of nitric oxide. Seven pigs (24+/-2 kg BW) were surfactant-depleted by repeated lung lavage with saline. Gas exchange and hemodynamic parameters were assessed in all animals during gaseous and subsequent partial liquid ventilation at two levels of PEEP (5 and 15 cmH2O) and intermittent inhalation of 10 ppm NO. Arterial oxygenation increased significantly with a simultaneous decrease in cardiac output when PEEP 15 cmH2O was applied during gaseous and partial liquid ventilation. All other hemodynamic parameters revealed no relevant changes. Inhalation of NO and instillation of perfluorocarbon had no additive effects on pulmonary gas exchange when compared to PEEP 15 cmH2O alone. In experimental lung injury, improvements in gas exchange are most distinct during mechanical ventilation with PEEP 15 cmH2O without significantly impairing hemodynamics. Partial liquid ventilation and inhaled NO did not cause an additive increase of PaO2.

  11. Influence of a Gas Exchange Correction Procedure on Resting Metabolic Rate and Respiratory Quotient in Humans.

    Science.gov (United States)

    Galgani, Jose E; Castro-Sepulveda, Mauricio A

    2017-11-01

    The aim of this study was to determine the influence of a gas exchange correction protocol on resting metabolic rate (RMR) and respiratory quotient (RQ), assessed by a Vmax Encore 29n metabolic cart (SensorMedics Co., Yorba Linda, California) in overnight fasted and fed humans, and to assess the predictive power of body size for corrected and uncorrected RMR. Healthy participants (23 M/29 F; 34 ± 9 years old; 26.3 ± 3.7 kg/m 2 ) ingested two 3-hour-apart glucose loads (75 g). Indirect calorimetry was conducted before and hourly over a 6-hour period. Immediately after indirect calorimetry assessment, gas exchange was simulated through high-precision mass-flow regulators, which permitted the correction of RMR and RQ values. Uncorrected and corrected RMR and RQ were directly related at each time over the 6-hour period. However, uncorrected versus corrected RMR was 6.9% ± 0.5% higher (128 ± 7 kcal/d; P exchange in humans over a 6-hour period is feasible and provides information of improved accuracy. © 2017 The Obesity Society.

  12. Gas exchange and heart rate in the harbour porpoise, Phocoena phocoena

    DEFF Research Database (Denmark)

    Reed, J.Z.; Chambers, C.; Hunter, C.J.

    2000-01-01

    a comparatively high minute rate of gas exchange. Oxygen consumption under these experimental conditions (247 +/- 13.8 ml O-2. min(-1)) was 1.9- fold higher than predicted by standard scaling relations. These data together with an estimate of the total oxygen stores predicted an aerobic dive limit of 5.4 min......The respiratory physiology, heart rates and metabolic rates of two captive juvenile male harbour porpoises (both 28 kg) were measured using a rapid-response respiratory gas analysis system in the laboratory. Breath-hold durations in the laboratory (12 +/- 0.3 s, mean +/- SEM) were shorter than...... field observations. although a few breath-holds of over 40 s were recorded. The mean percentage time spent submerged was 89 +/- 0.4%. Relative to similarly-sized terrestrial mammals, the respiratory frequency was low (4.9 +/- 0.19 breaths min(-1)) but with high tidal volumes (1.1 +/- 0.01 l), enabling...

  13. Gas exchange in fruits related to skin condition and fruit ripening studied with diode laser spectroscopy.

    Science.gov (United States)

    Huang, Jing; Zhang, Hao; Lin, Huiying; Li, Tianqi; Mei, Liang; Svanberg, Katarina; Svanberg, Sune

    2016-12-01

    The concentration of the biologically active molecular oxygen gas is of crucial importance for fruits in the metabolic respiration, maturation, and ripening processes. In our study, oxygen content and oxygen transport in fruits, exemplified by apples and guavas, were studied noninvasively by gas in scattering media absorption spectroscopy. The technique is based on the fact that free gases typically have 10,000 times narrower absorption features than the bulk material. The technique was demonstrated in studies of the influence of the fruit skin in regulating the internal oxygen balance, by observing the signal response of the internal oxygen gas to a transient change in the ambient gas concentration on peeled and unpeeled fruits. In addition, the gas exchange rate at different ripening stages was also studied in intact guavas.

  14. Gas exchange in fruits related to skin condition and fruit ripening studied with diode laser spectroscopy

    Science.gov (United States)

    Huang, Jing; Zhang, Hao; Lin, Huiying; Li, Tianqi; Mei, Liang; Svanberg, Katarina; Svanberg, Sune

    2016-12-01

    The concentration of the biologically active molecular oxygen gas is of crucial importance for fruits in the metabolic respiration, maturation, and ripening processes. In our study, oxygen content and oxygen transport in fruits, exemplified by apples and guavas, were studied noninvasively by gas in scattering media absorption spectroscopy. The technique is based on the fact that free gases typically have 10,000 times narrower absorption features than the bulk material. The technique was demonstrated in studies of the influence of the fruit skin in regulating the internal oxygen balance, by observing the signal response of the internal oxygen gas to a transient change in the ambient gas concentration on peeled and unpeeled fruits. In addition, the gas exchange rate at different ripening stages was also studied in intact guavas.

  15. The 2008 intercomparison exercise for radon gas measurement instruments at PSI; Die Vergleichsmessung 2008 fuer Radongasmessgeraete am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2010-09-15

    Sixteen radon measurement services participated in the 2008 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) during August 28{sup th} to September 7{sup th}, 2008 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (etched-track, electronic and electret ionisation chambers) and instruments (ionization chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 627 Bq m{sup -3} leading to a radon gas exposure of 155 kBq h m{sup -3}. One measuring instrument participating for testing purposes stored values for part of the exposure interval (30.8. - 7.9.2008). The exposure during this partial interval was 117 kBq h m{sup -3} at an average radon gas concentration of 624 Bq m{sup -3}. The exposure of 155 kBq h m{sup -3} was the lowest used at the PSI intercomparisons down to the present day. Especially the LLT electret ionisation chambers used by some of the laboratories reached the lower end of their measurement range with this exposure. Unexpected deviations of instruments of the same model seem to show a dependence on the serial number and thus production date. (authors)

  16. Air/sea DMS gas transfer in the North Atlantic: evidence for limited interfacial gas exchange at high wind speed

    Science.gov (United States)

    Bell, T. G.; De Bruyn, W.; Miller, S. D.; Ward, B.; Christensen, K.; Saltzman, E. S.

    2013-05-01

    Shipboard measurements of eddy covariance DMS air/sea fluxes and seawater concentration were carried out in the North Atlantic bloom region in June/July 2011. Gas transfer coefficients (k660) show a linear dependence on mean horizontal wind speed at wind speeds up to 11 m s-1. At higher wind speeds the relationship between k660 and wind speed weakens. At high winds, measured DMS fluxes were lower than predicted based on the linear relationship between wind speed and interfacial stress extrapolated from low to intermediate wind speeds. In contrast, the transfer coefficient for sensible heat did not exhibit this effect. The apparent suppression of air/sea gas flux at higher wind speeds appears to be related to sea state, as determined from shipboard wave measurements. These observations are consistent with the idea that long waves suppress near surface water side turbulence, and decrease interfacial gas transfer. This effect may be more easily observed for DMS than for less soluble gases, such as CO2, because the air/sea exchange of DMS is controlled by interfacial rather than bubble-mediated gas transfer under high wind speed conditions.

  17. Assessment of salt tolerance of some newly developed and candidate wheat (triticum aestivum l.) cultivars using gas exchange and chlorophyll fluorescence attributes

    International Nuclear Information System (INIS)

    Kanwal, H.; Shahbaz, M.; Ashraf, M.

    2011-01-01

    The present study was aimed to assess salt tolerance of some newly developed and candidate cultivars of wheat using gas exchange and chlorophyll fluorescence parameters. Ten wheat cultivars including five newly developed (S-24, Saher-2006, Fsd-2008, Lasani and Inqlab-91) and five candidate (P .B-18, M.P-65, S.H-20, AARI-10 and G.A-20) were grown in sand culture. Salt stress (150 mM NaCl in Hoagland's nutrient solution) was applied at the seedling stage. A significant reduction in plant biomass production was recorded in all wheat cultivars. Cultivars S-24, Saher-2006 and Fsd-2008 showed less reduction in biomass production as compared with the other cultivars. Different gas exchange attributes such as leaf net photosynthetic rate (A), transpiration rate ( E), and stomatal conductance (gs) were also adversely affected due to salt stress and were positively associated with the plant biomass production of the genotypes under saline stress. More negative effects in relation to these gas exchange attributes were recorded in cvs. Lasani, G.A-20 and ARRI-10 than those in the other cultivars. Leaf maximum chlorophyll fluorescence (Fm), maximum fluorescence at steady state (Fms ), and photochemical fluorescence quenching (Qp) increased while maximum quantum yield (Fv/Fm), quantum yield of electron transport (Qp), electron transport rate ( ETR ) and non-photochemical quenching (Qn) decreased due to imposition of salt stress. The adverse effects of salt stress on these chlorophyll fluorescence attributes were minimum in cultivars S-24, Saher-2006 and Fsd-2008. A significant positive correlation was recorded between biomass production, different gas exchange attributes and chlorophyll fluorescence parameters. Overall, cvs. S-24, Saher-2006 and Fsd-2008 were ranked as salt tolerant on the basis of their performance in biomass production, gas exchange attributes and chlorophyll fluorescence parameters. (author)

  18. A Numerical Study on Using Air Cooler Heat Exchanger for Low Grade Energy Recovery from Exhaust Flue Gas in Natural Gas Pressure Reduction Stations

    OpenAIRE

    Mansoor Naderi; Ghasem Zargar; Ebrahim Khalili

    2018-01-01

    Heat EXchangers (HEX) that are used in City Gate Station (CGS) systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the cooling fluid. Then, the effects of sizes and numbers of fins and tube rows on recovered heat rate were in...

  19. Process for removing a mixture containing iodine and alkyl iodine compounds from a gas phase or aqueous solution with ion-exchange resins

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, H; Mizuuchi, A; Yokoyama, F

    1968-10-04

    Iodine and alkyl iodine compounds are removed from a gas phase or aqueous solution containing salts, iodine and iodine compounds, such as the ambient gas in a reactor, if an accident should occur. The process comprises contacting the phase or solution: (a) with a hydrogen type strongly acidic cationic exchange resin, (b) with an anionic exchange resin containing quarternary ammonium and (c) with an anionic exchange resin containing free basic type tertiary amine, in this order or by reversing the order of the two anionic exchange resins. Although no problems arise in the liquid phase reaction, the ion-exchange resins in the gas phase reaction are desired in the moist state in order to stable maintain the migration speed of the materials to be removed regardless of the relative humidity of the amibent gas. In example I, Amberlite IRA-900 of 200 mm thickness as the lowermost bed, Amberlite IRA93 of 200 mm thickness as the middle bed and Amberlite 200 of 200 mm thickness as the uppermost bed were filled respectively, in a methacrylate resin cylinder with an inner diameter of 25 mm. A solution containing 15.9 mg/1 of iodine, 41.2 mg/1 of methyl iodide and 550 mg/1 of sodium carbonate flows at a rate of 15 liter/hr downward through the beds. As a result of testing, no iodine, iodine ions, iodic acid ions and methyl iodine were detected. The amount of water the beds could treat was 60 times the total quantity of the filled resins.

  20. Responses to water stress of gas exchange and metabolites in Eucalyptus and Acacia spp.

    Science.gov (United States)

    Warren, Charles R; Aranda, Ismael; Cano, F Javier

    2011-10-01

    Studies of water stress commonly examine either gas exchange or leaf metabolites, and many fail to quantify the concentration of CO₂ in the chloroplasts (C(c)). We redress these limitations by quantifying C(c) from discrimination against ¹³CO₂ and using gas chromatography-mass spectrometry (GC-MS) for leaf metabolite profiling. Five Eucalyptus and two Acacia species from semi-arid to mesic habitats were subjected to a 2 month water stress treatment (Ψ(pre-dawn) = -1.7 to -2.3 MPa). Carbohydrates dominated the leaf metabolite profiles of species from dry areas, whereas organic acids dominated the metabolite profiles of species from wet areas. Water stress caused large decreases in photosynthesis and C(c), increases in 17-33 metabolites and decreases in 0-9 metabolites. In most species, fructose, glucose and sucrose made major contributions to osmotic adjustment. In Acacia, significant osmotic adjustment was also caused by increases in pinitol, pipecolic acid and trans-4-hydroxypipecolic acid. There were also increases in low-abundance metabolites (e.g. proline and erythritol), and metabolites that are indicative of stress-induced changes in metabolism [e.g. γ-aminobutyric acid (GABA) shunt, photorespiration, phenylpropanoid pathway]. The response of gas exchange to water stress and rewatering is rather consistent among species originating from mesic to semi-arid habitats, and the general response of metabolites to water stress is rather similar, although the specific metabolites involved may vary. © 2011 Blackwell Publishing Ltd.

  1. A technique to simulate a tube break in a high-pressure gas/cooling water heat exchanger - HTR2008-58161

    International Nuclear Information System (INIS)

    Antwerpen, H. J. V.; Mulder, E. J.

    2008-01-01

    The gas cycles of most High Temperature Gas-Cooled Reactors (HTR's) reject heat to water at some stage. In the helium/water heat exchangers of HTR's with direct Brayton cycles, the helium is usually at a much higher pressure than the water. If the pressure boundary between the helium and the water fails inside the heat exchanger. the effect on the rest of the water system has to be established in order to do a proper system design. This can be done most efficiently by using a system simulation code, however, very few system simulation codes has the capability to do gas/liquid interface tracking as required for this problem. This study describes a calculation method with which a gas/liquid heat exchanger tube rupture can be calculated in a simulation code without interface tracking. The course of events after tube rupture is described and appropriate calculation models derived. A mathematical model for a pressure relief valve (PRV) was also created. The calculation models were implemented in the system simulation software Flownex and used to study a tube rupture on a 5000 kPa helium/water heat exchanger. The assembled calculation network solved stable and within reasonable time. The simulation provided insight into the course of events following the tube break. It was shown that the acceleration of water out of the helium cooler, by choked-flow helium, caused the main pressure pulses during the event. The maximum pressure in the water loop occurs on the opposite side of the helium cooler due to constructive interference of the initial pressure wave with itself. It was also shown that by changing only pipe lengths, the system could become prone to severe oscillations after a tube rupture event. (authors)

  2. Dry deposition and soil-air gas exchange of polychlorinated biphenyls (PCBs) in an industrial area.

    Science.gov (United States)

    Bozlaker, Ayse; Odabasi, Mustafa; Muezzinoglu, Aysen

    2008-12-01

    Ambient air and dry deposition, and soil samples were collected at the Aliaga industrial site in Izmir, Turkey. Atmospheric total (particle+gas) Sigma(41)-PCB concentrations were higher in summer (3370+/-1617 pg m(-3), average+SD) than in winter (1164+/-618 pg m(-3)), probably due to increased volatilization with temperature. Average particulate Sigma(41)-PCBs dry deposition fluxes were 349+/-183 and 469+/-328 ng m(-2) day(-1) in summer and winter, respectively. Overall average particulate deposition velocity was 5.5+/-3.5 cm s(-1). The spatial distribution of Sigma(41)-PCB soil concentrations (n=48) showed that the iron-steel plants, ship dismantling facilities, refinery and petrochemicals complex are the major sources in the area. Calculated air-soil exchange fluxes indicated that the contaminated soil is a secondary source to the atmosphere for lighter PCBs and as a sink for heavier ones. Comparable magnitude of gas exchange and dry particle deposition fluxes indicated that both mechanisms are equally important for PCB movement between air and soil in Aliaga.

  3. The Iġnik Sikumi Field Experiment, Alaska North Slope: Design, operations, and implications for CO2−CH4 exchange in gas hydrate reservoirs

    Science.gov (United States)

    Boswell, Ray; Schoderbek, David; Collett, Timothy S.; Ohtsuki, Satoshi; White, Mark; Anderson, Brian J.

    2017-01-01

    The Iġnik Sikumi Gas Hydrate Exchange Field Experiment was conducted by ConocoPhillips in partnership with the U.S. Department of Energy, the Japan Oil, Gas and Metals National Corporation, and the U.S. Geological Survey within the Prudhoe Bay Unit on the Alaska North Slope during 2011 and 2012. The primary goals of the program were to (1) determine the feasibility of gas injection into hydrate-bearing sand reservoirs and (2) observe reservoir response upon subsequent flowback in order to assess the potential for CO2 exchange for CH4 in naturally occurring gas hydrate reservoirs. Initial modeling determined that no feasible means of injection of pure CO2 was likely, given the presence of free water in the reservoir. Laboratory and numerical modeling studies indicated that the injection of a mixture of CO2 and N2 offered the best potential for gas injection and exchange. The test featured the following primary operational phases: (1) injection of a gaseous phase mixture of CO2, N2, and chemical tracers; (2) flowback conducted at downhole pressures above the stability threshold for native CH4 hydrate; and (3) an extended (30-days) flowback at pressures near, and then below, the stability threshold of native CH4 hydrate. The test findings indicate that the formation of a range of mixed-gas hydrates resulted in a net exchange of CO2 for CH4 in the reservoir, although the complexity of the subsurface environment renders the nature, extent, and efficiency of the exchange reaction uncertain. The next steps in the evaluation of exchange technology should feature multiple well applications; however, such field test programs will require extensive preparatory experimental and numerical modeling studies and will likely be a secondary priority to further field testing of production through depressurization. Additional insights gained from the field program include the following: (1) gas hydrate destabilization is self-limiting, dispelling any notion of the potential for

  4. Extended high-frequency partial liquid ventilation in lung injury: gas exchange, injury quantification, and vapor loss.

    Science.gov (United States)

    Doctor, Allan; Al-Khadra, Eman; Tan, Puay; Watson, Kenneth F; Diesen, Diana L; Workman, Lisa J; Thompson, John E; Rose, Charles E; Arnold, John H

    2003-09-01

    High-frequency oscillatory ventilation with perflubron (PFB) reportedly improves pulmonary mechanics and gas exchange and attenuates lung injury. We explored PFB evaporative loss kinetics, intrapulmonary PFB distribution, and dosing strategies during 15 h of high-frequency oscillation (HFO)-partial liquid ventilation (PLV). After saline lavage lung injury, 15 swine were rescued with high-frequency oscillatory ventilation (n = 5), or in addition received 10 ml/kg PFB delivered to dependent lung [n = 5, PLV-compartmented (PLV(C))] or 10 ml/kg distributed uniformly within the lung [n = 5, PLV(U)]. In the PLV(C) group, PFB vapor loss was replaced. ANOVA revealed an unsustained improvement in oxygenation index in the PLV(U) group (P = 0.04); the reduction in oxygenation index correlated with PFB losses. Although tissue myeloperoxidase activity was reduced globally by HFO-PLV (P PFB distribution optimized gas exchange during HFO-PLV; additionally, monitoring PFB evaporative loss appears necessary to stabilize intrapulmonary PFB volume.

  5. An Excel tool for deriving key photosynthetic parameters from combined gas exchange and chlorophyll fluorescence: theory and practice.

    Science.gov (United States)

    Bellasio, Chandra; Beerling, David J; Griffiths, Howard

    2016-06-01

    Combined photosynthetic gas exchange and modulated fluorometres are widely used to evaluate physiological characteristics associated with phenotypic and genotypic variation, whether in response to genetic manipulation or resource limitation in natural vegetation or crops. After describing relatively simple experimental procedures, we present the theoretical background to the derivation of photosynthetic parameters, and provide a freely available Excel-based fitting tool (EFT) that will be of use to specialists and non-specialists alike. We use data acquired in concurrent variable fluorescence-gas exchange experiments, where A/Ci and light-response curves have been measured under ambient and low oxygen. From these data, the EFT derives light respiration, initial PSII (photosystem II) photochemical yield, initial quantum yield for CO2 fixation, fraction of incident light harvested by PSII, initial quantum yield for electron transport, electron transport rate, rate of photorespiration, stomatal limitation, Rubisco (ribulose 1·5-bisphosphate carboxylase/oxygenase) rate of carboxylation and oxygenation, Rubisco specificity factor, mesophyll conductance to CO2 diffusion, light and CO2 compensation point, Rubisco apparent Michaelis-Menten constant, and Rubisco CO2 -saturated carboxylation rate. As an example, a complete analysis of gas exchange data on tobacco plants is provided. We also discuss potential measurement problems and pitfalls, and suggest how such empirical data could subsequently be used to parameterize predictive photosynthetic models. © 2015 John Wiley & Sons Ltd.

  6. Effects of prior short multiple-sprint exercises with different intersprint recoveries on the slow component of oxygen uptake during high-intensity exercise.

    Science.gov (United States)

    Lanzi, Stefano; Borrani, Fabio; Wolf, Martin; Gojanovic, Boris; Malatesta, Davide

    2012-12-01

    This study compares the effects of two short multiple-sprint exercise (MSE) (6 × 6 s) sessions with two different recovery durations (30 s or 180 s) on the slow component of oxygen uptake ([Formula: see text]O(2)) during subsequent high-intensity exercise. Ten male subjects performed a 6-min cycling test at 50% of the difference between the gas exchange threshold and [Formula: see text]O(2peak) (Δ50). Then, the subjects performed two MSEs of 6 × 6 s separated by two intersprint recoveries of 30 s (MSE(30)) and 180 s (MSE(180)), followed 10 min later by the Δ50 (Δ50(30) and Δ50(180), respectively). Electromyography (EMG) activities of the vastus medialis and lateralis were measured throughout each exercise bout. During MSE(30), muscle activity (root mean square) increased significantly (p ≤ 0.04), with a significant leftward-shifted median frequency of the power density spectrum (MDF; p ≤ 0.01), whereas MDF was significantly rightward-shifted during MSE(180) (p = 0.02). The mean [Formula: see text]O(2) value was significantly higher in MSE(30) than in MSE(180) (p motor units recruitment profile (i.e., change in the type of muscle fibers recruited) and (or) an improved muscle O(2) delivery during subsequent exercise.

  7. Effects of Increased Respiratory Resistance on Maximal O2 Uptake and Anaerobic Threshold during Incremental Exercise Tests

    OpenAIRE

    ÖZÇELİK, Oğuz

    2014-01-01

    This study was undertaken to assess whether maximal O2 uptake (VO2max) can be used as an index of measuring aerobic capacity under the condition of increased respiratory resistance. Seven male subjects performed two incremental exercise tests on a cycle ergometer on different days: one control (C) and one breathing through an 8 mm bore diameter respiratory resistance (R). Ventilatory and gas exchange responses were measured with a turbine volume transducer and mass spectrometry, and processed...

  8. Influence of current velocity and wind speed on air-water gas exchange in a mangrove estuary

    Science.gov (United States)

    Ho, David T.; Coffineau, Nathalie; Hickman, Benjamin; Chow, Nicholas; Koffman, Tobias; Schlosser, Peter

    2016-04-01

    Knowledge of air-water gas transfer velocities and water residence times is necessary to study the fate of mangrove derived carbon exported into surrounding estuaries and ultimately to determine carbon balances in mangrove ecosystems. For the first time, the 3He/SF6 dual tracer technique, which has been proven to be a powerful tool to determine gas transfer velocities in the ocean, is applied to Shark River, an estuary situated in the largest contiguous mangrove forest in North America. The mean gas transfer velocity was 3.3 ± 0.2 cm h-1 during the experiment, with a water residence time of 16.5 ± 2.0 days. We propose a gas exchange parameterization that takes into account the major sources of turbulence in the estuary (i.e., bottom generated shear and wind stress).

  9. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  10. Optical Pumping Spin Exchange 3He Gas Cells for Magnetic Resonance Imaging

    Science.gov (United States)

    Kim, W.; Stepanyan, S. S.; Kim, A.; Jung, Y.; Woo, S.; Yurov, M.; Jang, J.

    2009-08-01

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the 3He-N2 mixture. The cells could be refilled. The 3He reaches around 50% polarization in 5-15 hours.

  11. Efficiency enhancement of a gas turbine cycle using an optimized tubular recuperative heat exchanger

    International Nuclear Information System (INIS)

    Sayyaadi, Hoseyn; Mehrabipour, Reza

    2012-01-01

    A simple gas turbine cycle namely as the Kraftwerk Union AG unit including a Siemens gas turbine model V93.1 with 60 MW nominal power and 26.0% thermal efficiency utilized in the Fars power plant located is considered for the efficiency enhancement. A typical tubular vertical recuperative heat exchanger is designed in order to integrate into the cycle as an air pre-heater for thermal efficiency improvement. Thermal and geometric specifications of the recuperative heat exchanger are obtained in a multi-objective optimization process. The exergetic efficiency of the gas cycle is maximized while the payback time for the capital investment of the recuperator is minimized. Combination of these objectives and decision variables with suitable engineering and physical constraints makes a set of the MINLP optimization problem. Optimization programming is performed using the NSGA-II algorithm and Pareto optimal frontiers are obtained in three cases including the minimum, average and maximum ambient air temperatures. In each case, the final optimal solution has been selected using three decision-making approaches including the fuzzy Bellman-Zadeh, LINMAP and TOPSIS methods. It has been shown that the TOPSIS and LINMAP decision-makers when applied on the Pareto frontier which is obtained at average ambient air temperature yields best results in comparison to other cases. -- Highlights: ► A simple Brayton gas cycle is considered for the efficiency improvement by integrating of a recuperator. ► Objective functions based on thermodynamic and economic analysis are obtained. ► The payback time for the capital investment is minimized and the exergetic efficiency of the system is maximized. ► Pareto optimal frontiers at various site conditions are obtained. ► A final optimal configuration is found using various decision-making approaches.

  12. Plant water use efficiency over geological time--evolution of leaf stomata configurations affecting plant gas exchange.

    Science.gov (United States)

    Assouline, Shmuel; Or, Dani

    2013-01-01

    Plant gas exchange is a key process shaping global hydrological and carbon cycles and is often characterized by plant water use efficiency (WUE - the ratio of CO2 gain to water vapor loss). Plant fossil record suggests that plant adaptation to changing atmospheric CO2 involved correlated evolution of stomata density (d) and size (s), and related maximal aperture, amax . We interpreted the fossil record of s and d correlated evolution during the Phanerozoic to quantify impacts on gas conductance affecting plant transpiration, E, and CO2 uptake, A, independently, and consequently, on plant WUE. A shift in stomata configuration from large s-low d to small s-high d in response to decreasing atmospheric CO2 resulted in large changes in plant gas exchange characteristics. The relationships between gas conductance, gws , A and E and maximal relative transpiring leaf area, (amax ⋅d), exhibited hysteretic-like behavior. The new WUE trend derived from independent estimates of A and E differs from established WUE-CO2 trends for atmospheric CO2 concentrations exceeding 1,200 ppm. In contrast with a nearly-linear decrease in WUE with decreasing CO2 obtained by standard methods, the newly estimated WUE trend exhibits remarkably stable values for an extended geologic period during which atmospheric CO2 dropped from 3,500 to 1,200 ppm. Pending additional tests, the findings may affect projected impacts of increased atmospheric CO2 on components of the global hydrological cycle.

  13. Trace gas exchange above the floor of a deciduous forest: 1. Evaporation and CO2 efflux

    Science.gov (United States)

    Baldocchi, Dennis D.; Meyers, Tilden P.

    1991-04-01

    The eddy correlation method has great potential for directly measuring trace gas fluxes at the floor of a forest canopy, but a thorough validation study has not been yet conducted. Another appeal of the eddy correlation method is its ability to study processes that regulate and modulate gas exchange between the soil/litter complex and the atmosphere that cannot be probed with chambers. In this paper we report on eddy correlation measurements of water vapor, sensible heat, and carbon dioxide exchange that were made at the floor of a deciduous forest. The validity of the eddy correlation method to measure the emission of water vapor and CO2 from a deciduous forest floor is demonstrated by our ability to close the surface energy budget during periods that meet the requirements of the technique. Water vapor fluxes from a dry forest floor are strongly influenced by large-scale turbulent events that penetrate deep into the canopy. The frequency of these turbulent events prevents equilibrium evaporation rates from being achieved because the dynamic time constant for water vapor exchange is longer. Consequently, maximal evaporation rates are capped to rates defined by the product of the driving potential of the atmosphere and the surface conductance. On the other hand, evaporation from a wet forest floor proceeds at rates reaching or exceeding equilibrium evaporation and are highly correlated with static pressure fluctuations. CO2 efflux rates are governed by litter and soil temperature, as expected. But we also find a significant correlation between static pressure fluctuations and soil/litter CO2 exchange rates.

  14. Air-sea dimethylsulfide (DMS) gas transfer in the North Atlantic: evidence for limited interfacial gas exchange at high wind speed

    Science.gov (United States)

    Bell, T. G.; De Bruyn, W.; Miller, S. D.; Ward, B.; Christensen, K.; Saltzman, E. S.

    2013-11-01

    Shipboard measurements of eddy covariance dimethylsulfide (DMS) air-sea fluxes and seawater concentration were carried out in the North Atlantic bloom region in June/July 2011. Gas transfer coefficients (k660) show a linear dependence on mean horizontal wind speed at wind speeds up to 11 m s-1. At higher wind speeds the relationship between k660 and wind speed weakens. At high winds, measured DMS fluxes were lower than predicted based on the linear relationship between wind speed and interfacial stress extrapolated from low to intermediate wind speeds. In contrast, the transfer coefficient for sensible heat did not exhibit this effect. The apparent suppression of air-sea gas flux at higher wind speeds appears to be related to sea state, as determined from shipboard wave measurements. These observations are consistent with the idea that long waves suppress near-surface water-side turbulence, and decrease interfacial gas transfer. This effect may be more easily observed for DMS than for less soluble gases, such as CO2, because the air-sea exchange of DMS is controlled by interfacial rather than bubble-mediated gas transfer under high wind speed conditions.

  15. Control of the exercise hyperpnoea in humans: a modeling perspective.

    Science.gov (United States)

    Ward, S A

    2000-09-01

    Models of the exercise hyperpnoea have classically incorporated elements of proportional feedback (carotid and medullary chemosensory) and feedforward (central and/or peripheral neurogenic) control. However, the precise details of the control process remain unresolved, reflecting in part both technical and interpretational limitations inherent in isolating putative control mechanisms in the intact human, and also the challenges to linear control theory presented by multiple-input integration, especially with regard to the ventilatory and gas-exchange complexities encountered at work rates which engender a metabolic acidosis. While some combination of neurogenic, chemoreflex and circulatory-coupled processes are likely to contribute to the control, the system appears to evidence considerable redundancy. This, coupled with the lack of appreciable error signals in the mean levels of arterial blood gas tensions and pH over a wide range of work rates, has motivated the formulation of innovative control models that reflect not only spatial interactions but also temporal interactions (i.e. memory). The challenge is to discriminate between robust competing control models that: (a) integrate such processes within plausible physiological equivalents; and (b) account for both the dynamic and steady-state system response over a range of exercise intensities. Such models are not yet available.

  16. Experimental study on CO2 frosting and clogging in a brazed plate heat exchanger for natural gas liquefaction process

    Science.gov (United States)

    Wu, Jitan; He, Tianbiao; Ju, Yonglin

    2018-04-01

    The plate-fin heat exchanger (PFHE), which has been widely used in natural gas liquefaction (LNG) industry at present, has some disadvantages such as being sensitive to the impurities in the feed gas, such as water, CO2 and H2S. Compared with the PFHE, the brazed plate heat exchanger (BPHE), which has been applied in some boil off gas (BOG) recycling LNG plants of small to middle size, has simpler inherent structure and higher impurity tolerance. In this study the BPHE is suggested to replace the PFHE to simplify or even omit the massive CO2 purification equipment for the LNG process. A set of experimental apparatus is designed and constructed to investigate the influence of the CO2 concentration of the natural gas on solid precipitation inside a typical BPHE meanly by considering the flow resistance throughout the LNG process. The results show that the maximum allowable CO2 concentration of the natural gas liquefied in the BPHE is two orders of magnitude higher than that in the PFHE under the same condition. In addition, the solid-liquid separation for the CO2 impurity is studied and the reasonable separating temperature is obtained. The solid CO2 should be separated below 135 K under the pressure of 3 MPa.

  17. Isotope exchange between gaseous hydrogen and uranium hydride powder

    International Nuclear Information System (INIS)

    Shugard, Andrew D.; Buffleben, George M.; Johnson, Terry A.; Robinson, David B.

    2014-01-01

    Highlights: • Isotope exchange between hydrogen gas and uranium hydride powder can be rapid and reversible. • Gas–solid exchange rate is controlled by transport within ∼0.7 μm hydride particles. • Gas chromatographic separation of hydrogen isotopes using uranium hydride is feasible. - Abstract: Isotope exchange between gaseous hydrogen and solid uranium hydride has been studied by flowing hydrogen (deuterium) gas through packed powder beds of uranium deuteride (hydride). We used a residual gas analyzer system to perform real-time analysis of the effluent gas composition. We also developed an exchange and transport model and, by fitting it to the experimental data, extracted kinetic parameters for the isotope exchange reaction. Our results suggest that, from approximately 70 to 700 kPa and 25 to 400 °C, the gas-to-solid exchange rate is controlled by hydrogen and deuterium transport within the ∼0.7 μm diameter uranium hydride particles. We use our kinetic parameters to show that gas chromatographic separation of hydrogen and deuterium using uranium hydride could be feasible

  18. Establishment in treeshelter. II. Effect of shelter color on gas exchange and hardiness

    International Nuclear Information System (INIS)

    Kjelgren, R.; Montague, D.T.; Rupp, L.A.

    1997-01-01

    We investigated the microclimate, gas exchange, and growth of feild-grown Norway maple (Acerplatanoides L.) and green ash (Fraxinus pennsylvanica Marsh) trees nonsheltered, and in brown and white shelters. Shelter microclimate-air temperature (Ta), vapor pressure deficit (VPD), and radiation -and tree leaf area, growth in diameter, stomatal conductance (gs), and photosynthesis were measured during the first growing season after bare-root transplanting. Bark temperatures in midwinter were also measured. Treeshelter microclimate was greenhouse-like compared to ambient conditions, as shortwave radiation was lower, and midday Ta and relative humidity were higher. Although trees in shelters had greater shoot elongation and higher gs than trees grown without shelters, photosynthesis was not different. White shelters allowed 25% more shortwave radiation penetration and increased Ta by 2 to 4 degrees C and VPD by 0.5-1 kPa over brown shelters. However, tree growth and gas exchange generally were not affected by shelter color. Winter injury was increased for trees in shelters and varied with species and shelter color. Both species exhibited shoot dieback in shelters the spring following a winter where bark temperatures varied 40 to 50 degrees C diurnally. More new growth died on maple, particularly in white shelters where several trees were killed. These data suggest that supra optimal summer and winter temperatures may reduce vigor and interfere with cold tolerance of some species grown in shelters

  19. Detecting abnormalities in left ventricular function during exercise by respiratory measurement

    International Nuclear Information System (INIS)

    Koike, A.; Itoh, H.; Taniguchi, K.; Hiroe, M.

    1989-01-01

    The degree of exercise-induced cardiac dysfunction and its relation to the anaerobic threshold were evaluated in 23 patients with chronic heart disease. A symptom-limited exercise test was performed with a cycle ergometer with work rate increased by 1 W every 6 seconds. Left ventricular function, as reflected by ejection fraction, was continuously monitored with a computerized cadmium telluride detector after the intravenous injection of technetium-labeled red blood cells. The anaerobic threshold (mean, 727 ± 166 ml/min) was determined by the noninvasive measurement of respiratory gas exchange. As work rate rose, the left ventricular ejection fraction increased but reached a peak value at the anaerobic threshold and then fell below resting levels. Ejection fraction at rest, anaerobic threshold, and peak exercise were 41.4 ± 11.3%, 46.5 ± 12.0%, and 37.2 ± 11.0%, respectively. Stroke volume also increased from rest (54.6 ± 17.0 ml/beat) to the point of the anaerobic threshold (65.0 ± 21.2 ml/beat) and then decreased at peak exercise (52.4 ± 18.7 ml/beat). The slope of the plot of cardiac output versus work rate decreased above the anaerobic threshold. The anaerobic threshold occurred at the work rate above which left ventricular function decreased during exercise. Accurate determination of the anaerobic threshold provides an objective, noninvasive measure of the oxygen uptake above which exercise-induced deterioration in left ventricular function occurs in patients with chronic heart disease

  20. A dynamic leaf gas-exchange strategy is conserved in woody plants under changing ambient CO2: evidence from carbon isotope discrimination in paleo and CO2 enrichment studies

    Science.gov (United States)

    Rising atmospheric [CO2], ca, is expected to affect stomatal regulation of leaf gas-exchange of woody plants, thus influencing energy fluxes as well as carbon (C), water and nutrient cycling of forests. Researchers have reported that stomata regulate leaf gas-exchange around “set...

  1. Greenhouse Gas Exchange in Small Arctic Thaw Ponds

    Science.gov (United States)

    Laurion, I.; Bégin, P. N.; Bouchard, F.; Preskienis, V.

    2014-12-01

    Arctic lakes and ponds can represent up to one quarter of the land surface in permafrost landscapes, particularly in lowland tundra landscapes characterized by ice wedge organic polygons. Thaw ponds can be defined as the aquatic ecosystems associated to thawing of organic soils, either resulting from active layer processes and located above low-center peat polygons (hereafter low-center polygonal or LCP ponds), or resulting from thermokarst slumping above melting ice wedges linked to the accelerated degradation of permafrost (hereafter ice-wedge trough or IWT ponds). These ponds can merge together forming larger water bodies, but with relatively stable shores (hereafter merged polygonal or MPG ponds), and with limnological characteristics similar to LCP ponds. These aquatic systems are very small and shallow, and present a different physical structure than the larger thermokarst lakes, generated after years of development and land subsidence. In a glacier valley on Bylot Island, Nunavut, Canada, thermokarst and kettle lakes together represent 29% of the aquatic area, with a thermal profile resembling those of more standard arctic lakes (mixed epilimnion). The IWT ponds (44% of the area) are stratified for a large fraction of the summer despite their shallowness, while LCP and MPG ponds (27% of the area) show a more homogeneous water column. This will affect gas exchange in these diverse aquatic systems, in addition to their unique microbiota and organic carbon lability that control the production and consumption rates of greenhouse gases. The stratification in IWT ponds generates hypoxic conditions at the bottom, and together with the larger availability of organic carbon, stimulates methanogenesis and limits the mitigating action of methanotrophs. Overall, thaw ponds are largely supersaturated in methane, with IWT ponds dominating the emissions in this landscape (92% of total aquatic emissions estimated for the same valley), and they present large variations in

  2. Gas exchange and growth responses to nutrient enrichment in invasive Glyceria maxima and native New Zealand Carex species

    DEFF Research Database (Denmark)

    Sorrell, Brian Keith; Brix, Hans; Fitridge, Isla

    2012-01-01

    We compared photosynthetic gas exchange, the photosynthesis-leaf nitrogen (N) relationship, and growth response to nutrient enrichment in the invasive wetland grass Glyceria maxima (Hartman) Holmburg with two native New Zealand Carex sedges (C. virgata Boott and C. secta Boott), to explore...... the ecophysiological traits contributing to invasive behaviour. The photosynthesis-nitrogen relationship was uniform across all three species, and the maximum light-saturated rate of photosynthesis expressed on a leaf area basis (Amaxa) did not differ significantly between species. However, specific leaf area (SLA...... the sedges, but correlations between leaf N, gas exchange parameters (Amaxa, Amaxm, Rd and gs) and RGR were all highly significant in G. maxima, whereas they were weak or absent in the sedges. Allocation of biomass (root:shoot ratio, leaf mass ratio, root mass ratio), plant N and P content, and allocation...

  3. Energy metabolism of medium-chain triglycerides versus carbohydrates during exercise.

    Science.gov (United States)

    Décombaz, J; Arnaud, M J; Milon, H; Moesch, H; Philippossian, G; Thélin, A L; Howald, H

    1983-01-01

    Medium-chain triglycerides (MCT) are known to be rapidly digested and oxidized. Their potential value as a source of dietary energy during exercise was compared with that of maltodextrins (MD). Twelve subjects exercised for 1 h on a bicycle ergometer (60% VO2 max), 1 h after the test meal (1MJ). The metabolism of MCT was followed using 1-13C-octanoate (Oc) as tracer and U-13C-glucose (G) was added to the 13C-naturally enriched MD. After MCT ingestion no insulin peak was observed with some accumulation of ketone bodies (KB), blood levels not exceeding 1 mM. Total losses of KB during exercise in urine, sweat and as breath acetone were small (less than 0.2 mmol X h-1). Hence, the influence of KB loss and storage on gas exchange data was negligible. The partition of fat and carbohydrate utilization during exercise as obtained by indirect calorimetry was practically the same after the MCT and the CHO meals. Oxidation over the 2-h period was 30% of dose for Oc and 45% for G. Glycogen decrements in the Vastus lateralis muscle were equal. It appears that with normal carbohydrate stores, a single meal of MCT or CHO did not alter the contribution of carbohydrates during 1 h of high submaximal exercise. The moderate ketonemia after MCT, despite substantial oxidation of this fat, led to no difference in muscle glycogen sparing between the diets.

  4. Deriving C4 photosynthetic parameters from combined gas exchange and chlorophyll fluorescence using an Excel tool: theory and practice.

    Science.gov (United States)

    Bellasio, Chandra; Beerling, David J; Griffiths, Howard

    2016-06-01

    The higher photosynthetic potential of C4 plants has led to extensive research over the past 50 years, including C4 -dominated natural biomes, crops such as maize, or for evaluating the transfer of C4 traits into C3 lineages. Photosynthetic gas exchange can be measured in air or in a 2% Oxygen mixture using readily available commercial gas exchange and modulated PSII fluorescence systems. Interpretation of these data, however, requires an understanding (or the development) of various modelling approaches, which limit the use by non-specialists. In this paper we present an accessible summary of the theory behind the analysis and derivation of C4 photosynthetic parameters, and provide a freely available Excel Fitting Tool (EFT), making rigorous C4 data analysis accessible to a broader audience. Outputs include those defining C4 photochemical and biochemical efficiency, the rate of photorespiration, bundle sheath conductance to CO2 diffusion and the in vivo biochemical constants for PEP carboxylase. The EFT compares several methodological variants proposed by different investigators, allowing users to choose the level of complexity required to interpret data. We provide a complete analysis of gas exchange data on maize (as a model C4 organism and key global crop) to illustrate the approaches, their analysis and interpretation. © 2015 John Wiley & Sons Ltd. © 2016 John Wiley & Sons Ltd.

  5. Factors controlling sulfur gas exchange in Sphagnum-dominated wetlands

    Science.gov (United States)

    Demello, William Zamboni; Hines, Mark E.; Bayley, Suzanne E.

    1992-01-01

    Atmosphere-peatland exchange of reduced sulfur gases was determined seasonally in fen in NH, and in an artificially-acidified fen at the Experimental Lakes Area (ELA) in Canada. Dimethyl sulfide (DMS) dominated gas fluxes at rates as high as 400 nmol/m(sup -2)hr(sup -1). DMS fluxes measured using enclosures were much higher than those calculated using a stagnant-film model, suggesting that Sphagnum regulated efflux. Temperature controlled diel and seasonal variability in DMS emissions. Use of differing enclosure techniques indicated that vegetated peatlands consume atmospheric carbonyl sulfide. Sulfate amendments caused DMS and methane thiol concentrations in near-surface pore waters to increase rapidly, but fluxes of these gases to the atmosphere were not affected. However, emission data from sites experiencing large differences in rates of sulfate deposition from the atmosphere suggested that chronic elevated sulfate inputs enhance DMS emissions from northern wetlands.

  6. Influence of extreme pedal rates on pulmonary O(2) uptake kinetics during transitions to high-intensity exercise from an elevated baseline.

    Science.gov (United States)

    Dimenna, Fred J; Wilkerson, Daryl P; Burnley, Mark; Bailey, Stephen J; Jones, Andrew M

    2009-10-31

    We used extreme pedal rates to investigate the influence of muscle fibre recruitment on pulmonary V(O)(2) kinetics during unloaded-to-moderate-intensity (U-->M), unloaded-to-high-intensity (U-->H), and moderate-intensity to high-intensity (M-->H) cycling transitions. Seven healthy men completed transitions to 60% of the difference between gas-exchange threshold and peak V(O)(2) from both an unloaded and a moderate-intensity (95% GET) baseline at cadences of 35 and 115rpm. Pulmonary gas exchange was measured breath-by-breath and iEMG of the m. vastus lateralis and m. gluteus maximus was measured during all tests. At 35rpm, the phase II time constant (tau(p)) values for U-->M, U-->H, and M-->H were 26+/-7, 31+/-7 and 36+/-8s with the value for M-->H being longer than for U-->M (PM, U-->H, and M-->H were 29+/-8, 48+/-16 and 53+/-20s with the value for U-->M being shorter than for the other two conditions (Pinfluenced by an interaction of exercise intensity and pedal rate and are consistent with the notion that changes in muscle fibre recruitment are responsible for slower phase II V(O)(2) kinetics during high-intensity and work-to-work exercise transitions.

  7. Differential leaf gas exchange performance of mango cultivars infected by different isolates of Ceratocystis fimbriata

    Directory of Open Access Journals (Sweden)

    Wilka Messner da Silva Bispo

    2016-04-01

    Full Text Available ABSTRACT Caused by the vascular fungus Ceratocystis fimbriata, mango wilt is considered to be one of the most serious threats in mango-producing regions worldwide. However, changes in leaf gas exchange level and the mechanisms underlying host responses to this fungal infection remain poorly described. This study aimed to evaluate potential changes in the leaf gas exchange of different mango cultivars (Ubá, Espada, Haden and Tommy Atkins in response to two Brazilian isolates of C. fimbriata (CEBS15 and MSAK16 to non-invasively assess cultivar variability in relation to the basal level of resistance to mango wilt. Both isolates, regardless of the cultivar, caused reductions in stomatal conductance and, thus, a reduction in CO2 assimilation via diffusive limitations. Taking into account the full length of the internal lesion and the radial colonization of the stem tissues, both isolates showed equivalent aggressiveness when inoculated into the Haden and Tommy Atkins cultivars. Conversely, when compared to the CEBS15 isolate of C. fimbriata, the MSAK16 isolate was more aggressive in cv. Espada and less aggressive in cv. Ubá.

  8. Disruption of stomatal lineage signaling or transcriptional regulators has differential effects on mesophyll development, but maintains coordination of gas exchange.

    Science.gov (United States)

    Dow, Graham J; Berry, Joseph A; Bergmann, Dominique C

    2017-10-01

    Stomata are simultaneously tasked with permitting the uptake of carbon dioxide for photosynthesis while limiting water loss from the plant. This process is mainly regulated by guard cell control of the stomatal aperture, but recent advancements have highlighted the importance of several genes that control stomatal development. Using targeted genetic manipulations of the stomatal lineage and a combination of gas exchange and microscopy techniques, we show that changes in stomatal development of the epidermal layer lead to coupled changes in the underlying mesophyll tissues. This coordinated response tends to match leaf photosynthetic potential (V cmax ) with gas-exchange capacity (g smax ), and hence the uptake of carbon dioxide for water lost. We found that different genetic regulators systematically altered tissue coordination in separate ways: the transcription factor SPEECHLESS (SPCH) primarily affected leaf size and thickness, whereas peptides in the EPIDERMAL PATTERNING FACTOR (EPF) family altered cell density in the mesophyll. It was also determined that interlayer coordination required the cell-surface receptor TOO MANY MOUTHS (TMM). These results demonstrate that stomata-specific regulators can alter mesophyll properties, which provides insight into how molecular pathways can organize leaf tissues to coordinate gas exchange and suggests new strategies for improving plant water-use efficiency. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  9. Design of Plant Gas Exchange Experiments in a Variable Pressure Growth Chamber

    Science.gov (United States)

    Corey, Kenneth A.

    1996-01-01

    Sustainable human presence in extreme environments such as lunar and martian bases will require bioregenerative components to human life support systems where plants are used for generation of oxygen, food, and water. Reduced atmospheric pressures will be used to minimize mass and engineering requirements. Few studies have assessed the metabolic and developmental responses of plants to reduced pressure and varied oxygen atmospheres. The first tests of hypobaric pressures on plant gas exchange and biomass production at the Johnson Space Center will be initiated in January 1996 in the Variable Pressure Growth Chamber (VPGC), a large, closed plant growth chamber rated for 10.2 psi. Experiments were designed and protocols detailed for two complete growouts each of lettuce and wheat to generate a general database for human life support requirements and to answer questions about plant growth processes in reduced pressure and varied oxygen environments. The central objective of crop growth studies in the VPGC is to determine the influence of reduced pressure and reduced oxygen on the rates of photosynthesis, dark respiration, evapotranspiration and biomass production of lettuce and wheat. Due to the constraint of one experimental unit, internal controls, called pressure transients, will be used to evaluate rates of CO2 uptake, O2 evolution, and H2O generation. Pressure transients will give interpretive power to the results of repeated growouts at both reduced and ambient pressures. Other experiments involve the generation of response functions to partial pressures of O2 and CO2 and to light intensity. Protocol for determining and calculating rates of gas exchange have been detailed. In order to build these databases and implement the necessary treatment combinations in short time periods, specific requirements for gas injections and removals have been defined. A set of system capability checks will include determination of leakage rates conducted prior to the actual crop

  10. Apparatus for concentrating by dual temperature exchange

    International Nuclear Information System (INIS)

    Spevack, J.S.

    1975-01-01

    The dual temperature exchange apparatus, with a dual temperature stage having a hot processing tower and a cold processing tower, is provided with means for transferring heat from the hot processed gas to both liquid and gas being delivered to the hot processing tower. The heat exchange system provides means for effecting direct contact between the hot processed gas and the cold processed liquid being delivered to the hot tower, means for establishing a circulation of the resulting heated processed liquid, and means including an indirect contact exchanger for transferring heat from said circulation to condition the gas being supplied to the hot processing tower. The reactants in the example given are hydrogen sulfide gas and liquid water

  11. A two-dimensional microscale model of gas exchange during photosynthesis in maize (Zea mays L.) leaves

    NARCIS (Netherlands)

    Retta, Moges; Ho, Quang Tri; Yin, Xinyou; Verboven, Pieter; Berghuijs, Herman N.C.; Struik, Paul C.; Nicolaï, Bart M.

    2016-01-01

    CO2 exchange in leaves of maize (Zea mays L.) was examined using a microscale model of combined gas diffusion and C4 photosynthesis kinetics at the leaf tissue level. Based on a generalized scheme of photosynthesis in NADP-malic enzyme type C4 plants, the model

  12. Effect of Magnesium on Gas Exchange and Photosynthetic Efficiency of Coffee Plants Grown under Different Light Levels

    Directory of Open Access Journals (Sweden)

    Kaio Gonçalves de Lima Dias

    2017-09-01

    Full Text Available The aim of the present study was to investigate the effects of magnesium on the gas exchange and photosynthetic efficiency of Coffee seedlings grown in nutrient solution under different light levels. The experiment was conducted under controlled conditions in growth chambers and nutrient solution at the Department of Plant Pathology of the Federal University of Lavras. The treatments consisted of five different Mg concentrations (0, 48, 96, 192 and 384 mg·L−1 and four light levels (80, 160, 240 and 320 µmol photon m−2·s−1. Both the Mg concentration and light levels affected gas exchange in the coffee plants. Photosynthesis increased linearly with the increasing light, indicating that the light levels tested were low for this crop. The highest CO2 assimilation rate, lowest transpiration, and highest water use efficiency were observed with 250 mg·Mg·L−1, indicating that this concentration was the optimal Mg supply for the tested light levels.

  13. Influence of a custom-made maxillary mouthguard on gas exchange parameters during incremental exercise in amateur road cyclists.

    Science.gov (United States)

    Piero, Malpezzi; Simone, Uliari; Jonathan, Myers; Maria, Spiridonova; Giulio, Grossi; Francesco, Terranova; Gabriella, Collini; Laura, Amabile; Eva, Bernardi; Gianni, Mazzoni; Francesco, Conconi; Giovanni, Grazzi

    2015-03-01

    Mouthguards are frequently used for protection purposes, particularly by athletes competing in contact sports. However, there is increasing evidence supporting their use for improving performance. Studies have focused their use in athletes who do not traditionally use mouthguards and who may be looking for a performance edge. The aim of the current study was to evaluate the influence of a custom-made mouthguard (Parabite Malpezzi, PM) on maximal and submaximal physiological parameters related to performance in road cycling. Ten well-trained amateur road cyclists (34 ± 6 years) performed an incremental cardiopulmonary exercise test to exhaustion on a frictional braked cycle ergometer. Work rate (WR), heart rate, oxygen consumption ((Equation is included in full-text article.)), carbon dioxide production, and ventilation at the lactate threshold, at the respiratory compensation point (RCP), and at maximal exercise (MAX) were determined in normal conditions (C) and wearing PM. Cycling economy was also evaluated by analyzing the slope of the (Equation is included in full-text article.)/WR (Δ(Equation is included in full-text article.)/ΔWR, in milliliters per watt per minute) relationship during the test. Wearing the PM compared with C resulted in significant increases in WR at RCP (281 ± 32 vs. 266 ± 19 W, p = 0.04) and at MAX (353 ± 44 vs. 339 ± 38 W, p = 0.004). The PM also resulted in an average 8% lower Δ(Equation is included in full-text article.)/ΔWR (9.5 ± 1.1 vs. 10.3 ± 1.1 ml·W·min, p = 0.06) but did not significantly modify any of the other measured parameters at LT, RCP and MAX. To the best of our knowledge, this study is the first to evaluate the effects of a dentistry-designed mouthguard on physical performance of road cyclists. These results provide support for cyclists to correct jaw posture that may improve their exercise performance.

  14. Gas exchange at the air-sea interface: a technique for radon measurements in seawater

    International Nuclear Information System (INIS)

    Queirazza, G.; Roveri, M.

    1991-01-01

    The rate of exchange of various gas species, such as O 2 , CO 2 etc. across the air-water interface can be evaluated from the 222 Rn vertical profiles in the water column. Radon profiles were measured in 4 stations in the NW Adriatic Sea, in September 1990, using solvent extraction and liquid scintillation counting techniques, directly on board the ship. The radiochemical procedure is described in detail. The lower limit of detection is approximately 0.4 mBq 1 -1 . The radon deficiency in the profiles gives estimates of the gas transfer rate across the air-sea interface ranging from 0.9 to 7.0 m d -1 . The suitability of the radon deficiency method in shallow water, enclosed seas is briefly discussed. (Author)

  15. Ventilation and gas exchange management after cardiac arrest.

    Science.gov (United States)

    Sutherasan, Yuda; Raimondo, Pasquale; Pelosi, Paolo

    2015-12-01

    For several decades, physicians had integrated several interventions aiming to improve the outcomes in post-cardiac arrest patients. However, the mortality rate after cardiac arrest is still as high as 50%. Post-cardiac arrest syndrome is associated with high morbidity and mortality due to not only poor neurological outcome and cardiovascular failure but also respiratory dysfunction. To minimize ventilator-associated lung injury, protective mechanical ventilation by using low tidal volume ventilation and driving pressure may decrease pulmonary complications and improve survival. Low level of positive end-expiratory pressure (PEEP) can be initiated and titrated with careful cardiac output and respiratory mechanics monitoring. Furthermore, optimizing gas exchange by avoiding hypoxia and hyperoxia as well as maintaining normocarbia may improve neurological and survival outcome. Early multidisciplinary cardiac rehabilitation intervention is recommended. Minimally invasive monitoring techniques, that is, echocardiography, transpulmonary thermodilution method measuring extravascular lung water, as well as transcranial Doppler ultrasound, might be useful to improve appropriate management of post-cardiac arrest patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Performance test of miniature heat exchangers with microchannels

    International Nuclear Information System (INIS)

    Hong, Yong Ju; Koh, Deuk Yong

    2005-01-01

    Etched microchannel heat exchanger, a subfield within MEMS, has high heat flux capability. This capability makes microchannels well-suited for a wide variety of application of cooling and chemical reaction. In this study, counter flow type miniature heat exchangers, which have flat metal plates with chemically etched microchannels, were manufactured by brazing method. Four type of the heat exchangers, which have straight microchannels, wavy shape microchannels, pin-fin channels and serpentine shape microchannels, were investigated to compare their thermal and hydraulic performance. Gas to gas heat exchange experiments were performed to measure the pressure drop and effectiveness of the heat exchangers at given gas flow rates and temperature difference

  17. Adults with initial metabolic syndrome have altered muscle deoxygenation during incremental exercise.

    Science.gov (United States)

    Machado, Alessandro da Costa; Barbosa, Thales Coelho; Kluser Sales, Allan Robson; de Souza, Marcio Nogueira; da Nóbrega, Antonio Claudio Lucas; Silva, Bruno Moreira

    2017-02-01

    Reduced aerobic power is independently associated with metabolic syndrome (MetS) incidence and prevalence in adults. This study investigated whether muscle deoxygenation (proxy of microvascular O 2 extraction) during incremental exercise is altered in MetS and associated with reduced oxygen consumption ( V˙O 2peak ). Twelve men with initial MetS (no overt diseases and medication-naive; mean ± SD, age 38 ± 7 years) and 12 healthy controls (HCs) (34 ± 7 years) completed an incremental cycling test to exhaustion, in which pulmonary ventilation and gas exchange (metabolic analyzer), as well as vastus lateralis deoxygenation (near infrared spectroscopy), were measured. Subjects with MetS, in contrast to HCs, showed lower V˙O 2peak normalized to total lean mass, similar V˙O 2 response to exercise, and earlier break point (BP) in muscle deoxygenation. Consequently, deoxygenation slope from BP to peak exercise was greater. Furthermore, absolute V˙O 2peak was positively associated with BP in correlations adjusted for total lean mass. MetS, without overt diseases, altered kinetics of muscle deoxygenation during incremental exercise, particularly at high-intensity exercise. Therefore, the balance between utilization and delivery of O 2 within skeletal muscle is impaired early in MetS natural history, which may contribute to the reduction in aerobic power. © 2017 The Obesity Society.

  18. A novel pump-driven veno-venous gas exchange system during extracorporeal CO2-removal.

    Science.gov (United States)

    Hermann, Alexander; Riss, Katharina; Schellongowski, Peter; Bojic, Andja; Wohlfarth, Philipp; Robak, Oliver; Sperr, Wolfgang R; Staudinger, Thomas

    2015-10-01

    Pump-driven veno-venous extracorporeal CO2-removal (ECCO2-R) increasingly takes root in hypercapnic lung failure to minimize ventilation invasiveness or to avoid intubation. A recently developed device (iLA activve(®), Novalung, Germany) allows effective decarboxylation via a 22 French double lumen cannula. To assess determinants of gas exchange, we prospectively evaluated the performance of ECCO2-R in ten patients receiving iLA activve(®) due to hypercapnic respiratory failure. Sweep gas flow was increased in steps from 1 to 14 L/min at constant blood flow (phase 1). Similarly, blood flow was gradually increased at constant sweep gas flow (phase 2). At each step gas transfer via the membrane as well as arterial blood gas samples were analyzed. During phase 1, we observed a significant increase in CO2 transfer together with a decrease in PaCO2 levels from a median of 66 mmHg (range 46-85) to 49 (31-65) mmHg from 1 to 14 L/min sweep gas flow (p gas flow rates. During phase 2, oxygen transfer significantly increased leading to an increase in PaO2 from 67 (49-87) at 0.5 L/min to 117 (66-305) mmHg at 2.0 L/min (p gas flow results in effective CO2-removal, which can be further reinforced by raising blood flow. The clinically relevant oxygenation effect in this setting could broaden the range of indications of the system and help to set up an individually tailored configuration.

  19. Market evaluation and investment planning in natural gas industry in Brazil: development of the net distribution pipeline; Avaliacao de mercado e planejamento de investimentos na industria de gas natural no Brasil: perspectivas de crescimento da malha de gasodutos de distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Pedro L.; Pamplona, Edson O. [Universidade Federal de Itajuba (UNIFEI), MG (Brazil)

    2008-07-01

    This paper proposes to develop a real options model to decision-making investments in flexible technologies. As a result, finding a closed-form solution, derived from the partial differential equation of the value of flexibility provided by alternative fuels. However, you can present and analysis the results of a practical application using the method to solve real options problems known as binomial model. Initially presents a brief explanation on the method of discounted cash flow, its failures and changes to the real options analysis. In the sequence chart an overview of the natural gas industry on Brazil, emphasizing the need for consistent investments evaluations in the sector. The next section shows the proposed development of mathematical model for assessing the flexibility to choose, obtained by the exchange of fuel for transport of gas pipeline distribution of natural gas. The model takes as the case scenario where the flexible pipeline can carry both natural gas and hydrogen, and the evaluation of the option of exchanging input gives more value to the investment opportunity, and consider the optimum conditions where the option to be exercised. Keywords: Decision Making, Real Options; Natural Gas, Flexible Technology. (author)

  20. The determinants of real exchange rate volatility in Nigeria | Ajao ...

    African Journals Online (AJOL)

    This study recommends that the central monetary authority should institute policies that will minimize the magnitude of exchange rate volatility while the federal government exercises control of viable macroeconomic variables which have direct influence on exchange rate fluctuation. Keywords: Exchange Rate, Volatility, ...

  1. Dissolution without disappearing: multicomponent gas exchange for CO2 bubbles in a microfluidic channel.

    Science.gov (United States)

    Shim, Suin; Wan, Jiandi; Hilgenfeldt, Sascha; Panchal, Prathamesh D; Stone, Howard A

    2014-07-21

    We studied the dissolution dynamics of CO2 gas bubbles in a microfluidic channel, both experimentally and theoretically. In the experiments, spherical CO2 bubbles in a flow of a solution of sodium dodecyl sulfate (SDS) first shrink rapidly before attaining an equilibrium size. In the rapid dissolution regime, the time to obtain a new equilibrium is 30 ms regardless of SDS concentration, and the equilibrium radius achieved varies with the SDS concentration. To explain the lack of complete dissolution, we interpret the results by considering the effects of other gases (O2, N2) that are already dissolved in the aqueous phase, and we develop a multicomponent dissolution model that includes the effect of surface tension and the liquid pressure drop along the channel. Solutions of the model for a stationary gas bubble show good agreement with the experimental results, which lead to our conclusion that the equilibrium regime is obtained by gas exchange between the bubbles and liquid phase. Also, our observations from experiments and model calculations suggest that SDS molecules on the gas-liquid interface form a diffusion barrier, which controls the dissolution behaviour and the eventual equilibrium radius of the bubble.

  2. Vascular recruitment in forearm muscles during exercise

    DEFF Research Database (Denmark)

    Palm, T; Nielsen, S L; Lassen, N A

    1983-01-01

    a more massive recruitment of exchange area during exercise (a factor 12) than suspected on the basis of ultrafiltration in animals made with the prolonged venous stasis technique (showing a factor 2-5). The estimated variability in exchange surface area indicates, that animal studies of muscle...

  3. Exercise tolerance in mitral stenosis and chronic obstructive pulmonary disease. Evaluation by anaerobic threshold and radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Uenami, Atsushi; Mizuno, Toshikazu; Chiba, Hiroshi; Ohno, Masanori; Wakino, Kouichi; Sawada, Yoshihiro; Ohno, Joichi; Kume, Kiyoshi

    1986-06-01

    Serial radionuclide ventriculography was performed using a newly developed ''real-time'' system, and left ventricular ejection fraction (LVEF), right ventricular ejection fraction (RVEF), stroke volume (SV), and cardiac output (CO) were measured during graded supine exercise in five patients with mitral stenosis (MS), in five patients with chronic obstructive pulmonary disease (COPD) and in five healthy subjects. Simultaneous pulmonary gas exchange analysis permitted determining the anaerobic threshold, which is the point during incremental exercise when lactate begins to accumulate in the blood. LVEF at the anaerobic threshold was not significantly changed in any patient groups and in healthy subjects, but RVEF at the anaerobic threshold was lower in COPD and MS patients as compared with healthy subjects. In MS, SV during exercise was reduced at the anaerobic threshold, but not in COPD or in healthy subjects. In conclusion, reduced working capacity is related to decreased RVEF in both COPD and MS, but the inhibited increase in CO during exercise is also important for the working capacity in MS.

  4. Is the rate of whole-body nitrogen elimination influenced by exercise?

    Science.gov (United States)

    Pendergast, D R; Senf, C; Lundgren, C E G

    2012-01-01

    Because it has earlier been shown that exercise 24 or two hours pre-dive may suppress the appearance of venous gas bubbles (VGB) in connection with the dive, we studied whether exercise before or during N2 elimination would influence the rate of the latter. Nitrogen elimination was recorded in eight volunteers breathing a normoxic O2+argon mixture for two hours. The N2 washout was preceded two (Condition A) or 24 hours (Condition B) earlier, by one hour of exercise at 85% VO2max (two hours of exercise interspersed with two hours of rest). In separate experiments, exercise at -40% of VO2max was performed throughout the two-hour washout (Condition C), and control experiments (Condition D) with denitrogenation without exercise were also performed. There were no significant differences among conditions for the total N2 eliminated (904 +/- 196 mL). The half-times of N2 washout for A (35.2 +/- 10.8 minutes) and B (31.9 +/- 8.6 minutes) did not differ from control washouts. The rate of washout in C increased 14% compared to D (half-time: 30.4 +/- 7.6 vs. 34.5 +/- 7.8 minutes, p = 0.002), and correlated with cardiac output. Exercise 24 or two hours pre-N2 washout did not affect it, suggesting that the decreased VGB scores noted by others in dives preceded by conditions similar to A and B are not due to changes in nitrogen exchange but rather to factors related to bubble formation and/or appearance. That N2 elimination is enhanced by concomitant exercise makes physiological sense but does not necessarily explain the observation by others of a reduced risk of decompression sickness with exercise before diving.

  5. Auxiliary Heat Exchanger Flow Distribution Test

    International Nuclear Information System (INIS)

    Kaufman, J.S.; Bressler, M.M.

    1983-01-01

    The Auxiliary Heat Exchanger Flow Distribution Test was the first part of a test program to develop a water-cooled (tube-side), compact heat exchanger for removing heat from the circulating gas in a high-temperature gas-cooled reactor (HTGR). Measurements of velocity and pressure were made with various shell side inlet and outlet configurations. A flow configuration was developed which provides acceptable velocity distribution throughout the heat exchanger without adding excessive pressure drop

  6. The Determinants of Real Exchange Rate Volatility in Nigeria

    African Journals Online (AJOL)

    Rahel

    magnitude of exchange rate volatility while the federal government exercises control of ... objectives in the area of price stability and economic growth. Volatile real ..... Exchange rate shocks and instability is a common feature of emerging.

  7. Hypoxia and hypercarbia in endophagous insects: Larval position in the plant gas exchange network is key.

    Science.gov (United States)

    Pincebourde, Sylvain; Casas, Jérôme

    2016-01-01

    Gas composition is an important component of any micro-environment. Insects, as the vast majority of living organisms, depend on O2 and CO2 concentrations in the air they breathe. Low O2 (hypoxia), and high CO2 (hypercarbia) levels can have a dramatic effect. For phytophagous insects that live within plant tissues (endophagous lifestyle), gas is exchanged between ambient air and the atmosphere within the insect habitat. The insect larva contributes to the modification of this environment by expiring CO2. Yet, knowledge on the gas exchange network in endophagous insects remains sparse. Our study identified mechanisms that modulate gas composition in the habitat of endophagous insects. Our aim was to show that the mere position of the insect larva within plant tissues could be used as a proxy for estimating risk of occurrence of hypoxia and hypercarbia, despite the widely diverse life history traits of these organisms. We developed a conceptual framework for a gas diffusion network determining gas composition in endophagous insect habitats. We applied this framework to mines, galls and insect tunnels (borers) by integrating the numerous obstacles along O2 and CO2 pathways. The nature and the direction of gas transfers depended on the physical structure of the insect habitat, the photosynthesis activity as well as stomatal behavior in plant tissues. We identified the insect larva position within the gas diffusion network as a predictor of risk exposure to hypoxia and hypercarbia. We ranked endophagous insect habitats in terms of risk of exposure to hypoxia and/or hypercarbia, from the more to the less risky as cambium mines>borer tunnels≫galls>bark mines>mines in aquatic plants>upper and lower surface mines. Furthermore, we showed that the photosynthetically active tissues likely assimilate larval CO2 produced. In addition, temperature of the microhabitat and atmospheric CO2 alter gas composition in the insect habitat. We predict that (i) hypoxia indirectly favors

  8. Tritium labelled nucleotides: Heterogeneous metal catalyzed exchange labelling of ATP with tritium gas

    International Nuclear Information System (INIS)

    Jaiswal, D.K.; Morimoto, H.; Williams, P.G.; Wemmer, D.E.

    1991-09-01

    Adenosine 5' triphosphate (ATP) in aqueous solution has been labeled by exchange with tritium gas in the presence of palladium oxide catalyst. Comparison with our experiments using Pd/BaSO 4 as the catalyst shows that we have obtained product with higher specific activity and improved chemical purity. 3 H NMR spectroscopy of the tritiated ATP shows labelling in both the C-8 and C-2 positions, and the integral ratio of these positions was found to vary from 3:1 to 1:1 under different reaction conditions. 5 refs., 1 fig., 2 tabs

  9. Fat utilization during exercise

    DEFF Research Database (Denmark)

    Helge, Jørn Wulff; Watt, Peter W.; Richter, Erik

    2001-01-01

    1. This study was carried out to test the hypothesis that the greater fat oxidation observed during exercise after adaptation to a high-fat diet is due to an increased uptake of fat originating from the bloodstream. 2. Of 13 male untrained subjects, seven consumed a fat-rich diet (62 % fat, 21...... % carbohydrate) and six consumed a carbohydrate-rich diet (20 % fat, 65 % carbohydrate). After 7 weeks of training and diet, 60 min of bicycle exercise was performed at 68 +/- 1 % of maximum oxygen uptake. During exercise [1-(13)C]palmitate was infused, arterial and venous femoral blood samples were collected......, and blood flow was determined by the thermodilution technique. Muscle biopsy samples were taken from the vastus lateralis muscle before and after exercise. 3. During exercise, the respiratory exchange ratio was significantly lower in subjects consuming the fat-rich diet (0.86 +/- 0.01, mean +/- S.E.M.) than...

  10. Decomposing method for ion exchange resin

    International Nuclear Information System (INIS)

    Sako, Takeshi; Sato, Shinshi; Akai, Yoshie; Moniwa, Shinobu; Yamada, Kazuo

    1998-01-01

    The present invention concerns a method of decomposing ion exchange resins generated in a nuclear power plant to carbon dioxide reliably in a short period of time. (1) The ion exchange resins are mixed with water, and then they are kept for a predetermined period of time in the presence of an inert gas at high temperature and high pressure exceeding the critical point of water to decompose the ion exchange resins. (2) The ion exchange resins is mixed with water, an oxidant is added and they are kept for a predetermined time in the presence of an inert gas at a high temperature and a high pressure exceeding a critical point of water of an inert gas at a high temperature to decompose the ion exchange resins. (3) An alkali or acid is added to ion exchange resins and water to control the hydrogen ion concentration in the solution and the ion exchange resins are decomposed in above-mentioned (1) or (2). Sodium hydroxide is used as the alkali and hydrochloric acid is used as the acid. In addition, oxygen, hydrogen peroxide or ozone is used as an oxidant. (I.S.)

  11. Gas Hydrate Storage of Natural Gas

    Energy Technology Data Exchange (ETDEWEB)

    Rudy Rogers; John Etheridge

    2006-03-31

    Environmental and economic benefits could accrue from a safe, above-ground, natural-gas storage process allowing electric power plants to utilize natural gas for peak load demands; numerous other applications of a gas storage process exist. A laboratory study conducted in 1999 to determine the feasibility of a gas-hydrates storage process looked promising. The subsequent scale-up of the process was designed to preserve important features of the laboratory apparatus: (1) symmetry of hydrate accumulation, (2) favorable surface area to volume ratio, (3) heat exchanger surfaces serving as hydrate adsorption surfaces, (4) refrigeration system to remove heat liberated from bulk hydrate formation, (5) rapid hydrate formation in a non-stirred system, (6) hydrate self-packing, and (7) heat-exchanger/adsorption plates serving dual purposes to add or extract energy for hydrate formation or decomposition. The hydrate formation/storage/decomposition Proof-of-Concept (POC) pressure vessel and supporting equipment were designed, constructed, and tested. This final report details the design of the scaled POC gas-hydrate storage process, some comments on its fabrication and installation, checkout of the equipment, procedures for conducting the experimental tests, and the test results. The design, construction, and installation of the equipment were on budget target, as was the tests that were subsequently conducted. The budget proposed was met. The primary goal of storing 5000-scf of natural gas in the gas hydrates was exceeded in the final test, as 5289-scf of gas storage was achieved in 54.33 hours. After this 54.33-hour period, as pressure in the formation vessel declined, additional gas went into the hydrates until equilibrium pressure/temperature was reached, so that ultimately more than the 5289-scf storage was achieved. The time required to store the 5000-scf (48.1 hours of operating time) was longer than designed. The lower gas hydrate formation rate is attributed to a

  12. Exchange of availability/performance data on base-load gas turbine and combined cycle plant

    Energy Technology Data Exchange (ETDEWEB)

    Jesuthasan, D.K.; Kaupang, B.M. (Tenaga Nasional Berhad (Malaysia))

    1992-09-01

    This paper describes the recommendations developed to facilitate the international exchange of availability performance data on base-load gas turbines and combined cycle plant. Standardized formats for the collection of plant availability statistics, recognizing the inherent characteristics of gas turbines in simple and combined cycle plants are presented. The formats also allow for a logical expansion of the data collection detail as that becomes desirable. To assist developing countries in particular, the approach includes basic formats for data collection needed for international reporting. In addition, the participating utilities will have a meaningful database for internal use. As experience is gained with this data colletion system, it is expected that additional detail may be accommodated to enable further in-depth performance analysis on the plant and on the utility level. 2 refs., 2 tabs., 11 apps.

  13. Polarization of stable and radioactive noble gas nuclei by spin exchange with laser pumped alkali atoms

    International Nuclear Information System (INIS)

    Calaprice, F.; Happer, W.; Schreiber, D.

    1984-01-01

    The nuclei of noble gases can be strongly polarized by spin exchange with sufficiently dense optically pumped alkali vapors. Only a small fraction of the spin angular momentum of the alkali atoms is transferred to the nuclear spin of the noble gas. Most of the spin angular momentum is lost to translational angular momentum of the alkali and noble gas atoms about each other. For heavy noble gases most of the angular momentum transfer occurs in alkali-noble-gas van der Waals molecules. The transfer efficiency depends on the formation and breakup rates of the van der Waals molecules in the ambient gas. Experimental methods to measure the spin transfer efficiencies have been developed. Nuclei of radioactive noble gases have been polarized by these methods, and the polarization has been detected by observing the anisotropy of the radioactive decay products. Very precise measurements of the magnetic moments of the radioactive nuclei have been made. 12 references, 9 figures

  14. CFD and FEM thermo-mechanical design of a recuperative-dissipative heat exchanger for a laboratory water gas shift reactor

    Energy Technology Data Exchange (ETDEWEB)

    Michele Vascellari; Stefano Sollai; Pier Francesco Orru; Giorgio Cau [University of Cagliari, Cagliari (Italy). Department of Mechanical Engineering

    2007-07-01

    A small scale test rig based on a two-stage reactor for testing water gas shift conversion processes has been set up at the Department of Mechanical Engineering at the University of Cagliari, chiefly for the purpose of supporting a pilot plant operation for high sulphur (Sulcis) coal gasification, gas cleaning and treatment, CO{sub 2} separation, hydrogen and electricity production. The laboratory test rig comprises two packed-bed reactors in series to be operated at different temperatures and has been designed for testing CO-shift conversion processes using a variety of catalysts for different syngas temperatures (up to 500{sup o}C) and compositions. One critical component of the system is a recuperative-dissipative heat exchanger placed between the two reactors. The heat exchanger, which preheats the syngas prior to entering the high temperature reactor and cools the shifted gas exiting there from, prior to its entering the low temperature reactor, is subjected to severe thermo-mechanical stress. Thus the design and analysis of this component, described herein, is a critical issue. A full 3D conjugate heat transfer CFD analysis of the tubular heat exchanger has been performed, considering different geometries. Based on the CFD results we were able to verify the preliminary design of the component, carried out using simple thermal correlations and to predict wall temperature distribution for the thermo-structural analysis. 10 refs., 10 figs., 2 tabs.

  15. Estimating CO2 gas exchange in mixed age vegetable plant communities grown on soil-like substrates for life support systems

    Science.gov (United States)

    Velichko, V. V.; Tikhomirov, A. A.; Ushakova, S. A.

    2018-02-01

    If soil-like substrate (SLS) is to be used in human life support systems with a high degree of mass closure, the rate of its gas exchange as a compartment for mineralization of plant biomass should be understood. The purpose of this study was to compare variations in CO2 gas exchange of vegetable plant communities grown on the soil-like substrate using a number of plant age groups, which determined the so-called conveyor interval. Two experimental plant communities were grown as plant conveyors with different conveyor intervals. The first plant community consisted of conveyors with intervals of 7 days for carrot and beet and 14 days for chufa sedge. The conveyor intervals in the second plant community were 14 days for carrot and beet and 28 days for chufa sedge. This study showed that increasing the number of age groups in the conveyor and, thus, increasing the frequency of adding plant waste to the SLS, decreased the range of variations in CO2 concentration in the "plant-soil-like substrate" system. However, the resultant CO2 gas exchange was shifted towards CO2 release to the atmosphere of the plant community with short conveyor intervals. The duration of the conveyor interval did not significantly affect productivity and mineral composition of plants grown on the SLS.

  16. Gas-phase ion/molecule isotope-exchange reactions: methodology for counting hydrogen atoms in specific organic structural environments by chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Hunt, D.F.; Sethi, S.K.

    1980-01-01

    Ion/molecule reactions are described which facilitate exchange of hydrogens for deuteriums in a variety of different chemical environments. Aromatic hydrogens in alkylbenzenes, oxygenated benzenes, m-toluidine, m-phenylenediamine, thiophene, and several polycyclic aromatic hydrocarbons and metallocenes are exchanged under positive ion CI conditions by using either D 2 O, EtOD, or ND 3 as the reagent gas. Aromatic hydrogens, benzylic hydrogens, and hydrogens on carbon adjacent to carbonyl groups suffer exchange under negative ion CI conditions in ND 3 , D 2 O, and EtOD, respectively. A possible mechanism for the exchange process is discussed. 1 figure, 2 tables

  17. Exchange functional by a range-separated exchange hole

    International Nuclear Information System (INIS)

    Toyoda, Masayuki; Ozaki, Taisuke

    2011-01-01

    An approximation to the exchange-hole density is proposed for the evaluation of the exact exchange energy in electronic structure calculations within the density-functional theory and the Kohn-Sham scheme. Based on the localized nature of density matrix, the exchange hole is divided into the short-range (SR) and long-range (LR) parts by using an adequate filter function, where the LR part is deduced by matching of moments with the exactly calculated SR counterpart, ensuring the correct asymptotic -1/r behavior of the exchange potential. With this division, the time-consuming integration is truncated at a certain interaction range, largely reducing the computation cost. The total energies, exchange energies, exchange potentials, and eigenvalues of the highest-occupied orbitals are calculated for the noble-gas atoms. The close agreement of the results with the exact values suggests the validity of the approximation.

  18. Combined Effects of Ventilation Mode and Positive End-Expiratory Pressure on Mechanics, Gas Exchange and the Epithelium in Mice with Acute Lung Injury

    Science.gov (United States)

    Thammanomai, Apiradee; Hamakawa, Hiroshi; Bartolák-Suki, Erzsébet; Suki, Béla

    2013-01-01

    The accepted protocol to ventilate patients with acute lung injury is to use low tidal volume (VT) in combination with recruitment maneuvers or positive end-expiratory pressure (PEEP). However, an important aspect of mechanical ventilation has not been considered: the combined effects of PEEP and ventilation modes on the integrity of the epithelium. Additionally, it is implicitly assumed that the best PEEP-VT combination also protects the epithelium. We aimed to investigate the effects of ventilation mode and PEEP on respiratory mechanics, peak airway pressures and gas exchange as well as on lung surfactant and epithelial cell integrity in mice with acute lung injury. HCl-injured mice were ventilated at PEEPs of 3 and 6 cmH2O with conventional ventilation (CV), CV with intermittent large breaths (CVLB) to promote recruitment, and a new mode, variable ventilation, optimized for mice (VVN). Mechanics and gas exchange were measured during ventilation and surfactant protein (SP)-B, proSP-B and E-cadherin levels were determined from lavage and lung homogenate. PEEP had a significant effect on mechanics, gas exchange and the epithelium. The higher PEEP reduced lung collapse and improved mechanics and gas exchange but it also down regulated surfactant release and production and increased epithelial cell injury. While CVLB was better than CV, VVN outperformed CVLB in recruitment, reduced epithelial injury and, via a dynamic mechanotransduction, it also triggered increased release and production of surfactant. For long-term outcome, selection of optimal PEEP and ventilation mode may be based on balancing lung physiology with epithelial injury. PMID:23326543

  19. Effect of multi-stream heat exchanger on performance of natural gas liquefaction with mixed refrigerant

    Science.gov (United States)

    Chang, Ho-Myung; Lim, Hye Su; Choe, Kun Hyung

    2012-12-01

    A thermodynamic study is carried out to investigate the effect of multi-stream heat exchanger on the performance of natural gas (NG) liquefaction with mixed refrigerant (MR). A cold stream (low-pressure MR) is in thermal contact with opposite flow of two hot streams (high-pressure MR and NG feed) at the same time. In typical process simulation with commercial software (such as Aspen HYSYS®), the liquefaction performance is estimated with a method of minimum temperature approach, simply assuming that two hot streams have the same temperature. In this study, local energy balance equations are rigorously solved with temperature-dependent properties of MR and NG feed, and are linked to the thermodynamic cycle analysis. The figure of merit (FOM) is quantitatively examined in terms of UA (the product of overall heat transfer coefficient and heat exchange area) between respective streams. In a single-stage MR process, it is concluded that the temperature profile from HYSYS is difficult to realize in practice, and the FOM value from HYSYS is an over-estimate, but can be closely achieved with a proper heat-exchanger design. It is also demonstrated that there exists a unique optimal ratio in three UA's, and no direct heat exchanger between hot streams is recommended.

  20. Exchange Bias Optimization by Controlled Oxidation of Cobalt Nanoparticle Films Prepared by Sputter Gas Aggregation

    Directory of Open Access Journals (Sweden)

    Ricardo López Antón

    2017-03-01

    Full Text Available Porous films of cobalt nanoparticles have been obtained by sputter gas aggregation and controllably oxidized by air annealing at 100 °C for progressively longer times (up to more than 1400 h. The magnetic properties of the samples were monitored during the process, with a focus on the exchange bias field. Air annealing proves to be a convenient way to control the Co/CoO ratio in the samples, allowing the optimization of the exchange bias field to a value above 6 kOe at 5 K. The occurrence of the maximum in the exchange bias field is understood in terms of the density of CoO uncompensated spins and their degree of pinning, with the former reducing and the latter increasing upon the growth of a progressively thicker CoO shell. Vertical shifts exhibited in the magnetization loops are found to correlate qualitatively with the peak in the exchange bias field, while an increase in vertical shift observed for longer oxidation times may be explained by a growing fraction of almost completely oxidized particles. The presence of a hummingbird-like form in magnetization loops can be understood in terms of a combination of hard (biased and soft (unbiased components; however, the precise origin of the soft phase is as yet unresolved.

  1. Improved Arterial–Ventricular Coupling in Metabolic Syndrome after Exercise Training

    Science.gov (United States)

    Fournier, Sara B.; Donley, David A.; Bonner, Daniel E.; DeVallance, Evan; Olfert, I. Mark; Chantler, Paul D.

    2014-01-01

    Purpose The metabolic syndrome (MetS) is associated with a three-fold increase risk of cardiovascular (CV) morbidity and mortality, which is in part, due to a blunted CV reserve capacity, reflected by a reduced peak exercise left ventricular contractility and aerobic capacity, and a blunted peak arterial-ventricular coupling. To date, no study has examined whether aerobic exercise training in MetS can reverse the peak exercise CV dysfunction. Further, examining how exercise training alters CV function in a group of individuals with MetS prior to the development of diabetes and/or overt CVD, can provide insights into whether some of the pathophysiological changes to the CV can be delayed/reversed, lowering their CV risk. The objective of this study was to examine the effects of 8 weeks of aerobic exercise training in individuals with MetS on resting and peak exercise CV function. Methods Twenty MetS underwent either 8 weeks of aerobic exercise training (MetS-ExT; n=10) or remained sedentary (MetS-NonT; n=10) during this time period. Resting and peak exercise CV function was characterized using Doppler echocardiography and gas exchange. Results Exercise training did not alter resting left ventricular diastolic or systolic function and arterial-ventricular coupling in MetS. In contrast, at peak exercise an increase in LV contractility (40%, p<0.01), cardiac output (28%, p<0.05) and aerobic capacity (20%, p<0.01), while a reduction in vascular resistance (30%, p<0.05) and arterial-ventricular coupling (27%, p<0.01), were noted in the MetS-ExT but not the MetS-NonT group. Further, an improvement in Lifetime Risk Score was also noted in the MetS-ExT group. Conclusions These findings have clinical importance as they provide insight that some of the pathophysiological changes associated with MetS can be improved and lower the risk of CVD. PMID:24870568

  2. The influence of water stress on plant hydraulics, gas exchange, berry composition and quality of Pinot Noir wines in Switzerland

    Directory of Open Access Journals (Sweden)

    Vivian Zufferey

    2017-04-01

    Full Text Available Aims : The aims of this study were to investigate the physiological behavior (plant hydraulics, gas exchange of the cultivar Pinot Noir in the field under progressively increasing conditions of water stress and analyze the effects of drought on grape and wine quality. Methods and results : Grapevines of the variety Vitis vinifera L. cv. Pinot Noir (clone 9-18, grafted onto 5BB were subjected to different water regimes (irrigation treatments over the growing season. Physiological indicators were used to monitor plant water status (leaf and stem water potentials and relative carbon isotope composition (d13C in must sugars. Leaf gas exchange (net photosynthesis A and transpiration E, leaf stomatal conductance (gs, specific hydraulic conductivity in petioles (Kpetiole, yield components, berry composition at harvest, and organoleptic quality of wines were analyzed over a 7-year period, between 2009 and 2015, under relatively dry conditions in the canton of Wallis, Switzerland. A progressively increasing water deficit, observed throughout the season, reduced the leaf gas exchange (A and E and gs in non-irrigated vines. The intrinsic water use efficiency (WUEi, A/gs increased during the growing season and was greater in water-stressed vines than in well-watered vines (irrigated vines. This rise in WUEi was correlated with an increase in d13C in must sugars at harvest. Drought led to decreases in Kpetiole, E and sap flow in stems. A decrease in vine plant vigor was observed in vines that had been subjected to water deficits year after year. Moderate water stress during ripening favored sugar accumulation in berries and caused a reduction in total acidic and malic contents in must and available nitrogen content (YAN. Wines produced from water-stressed vines had a deeper color and were richer in anthocyanins and phenol compounds compared with wines from well-watered vines with no water stress. The vine water status greatly influenced the organoleptic

  3. Data acquisition and quantitative analysis of stable hydrogen isotope in liquid and gas in the liquid phase catalytic exchange process

    International Nuclear Information System (INIS)

    Choi, H. J.; Lee, H. S.; Kim, K. R.; Cheong, H. S.; Ahn, D. H.; Lee, S. H.; Paek, S. W.; Kang, H. S.; Kim, J. G.

    2001-01-01

    A pilot plant for the Liquid Phase Catalytic Exchange process was built and has been operating to test the hydrophobic catalyst developed to remove the tritium generated at the CANDU nuclear power plants. The methods of quantitative analysis of hydrogen stable isotope were compared. Infrared spectroscopy was used for the liquid samples, and gas chromatography with hydrogen carrier gas showed the best result for gas samples. Also, a data acquisition system was developed to record the operation parameters. This record was very useful to investigate the causes of the system trip

  4. Aerobic fitness in patients with fibrositis. A controlled study of respiratory gas exchange and 133-xenon clearance from exercising muscle

    International Nuclear Information System (INIS)

    Bennett, R.M.; Clark, S.R.; Goldberg, L.; Nelson, D.; Bonafede, R.P.; Porter, J.; Specht, D.

    1989-01-01

    Aerobic fitness was evaluated in 25 women with fibrositis, by having them exercise to volitional exhaustion on an electronically braked cycle ergometer. Compared with published standards, greater than 80% of the fibrositis patients were not physically fit, as assessed by maximal oxygen uptake. Compared with matched sedentary controls, fibrositis patients accurately perceived their level of exertion in relation to oxygen consumption and attained a similar level of lactic acidosis, as assessed by their respiratory quotient and ventilatory threshold. Exercising muscle blood flow was estimated by 133-xenon clearance in a subgroup of 16 fibrositis patients and compared with that in 16 matched sedentary controls; the fibrositis patients exhibited reduced 133-xenon clearance. These results indicate a need to include aerobic fitness as a matched variable in future controlled studies of fibrositis and suggest that the detraining phenomenon may be of relevance to the etiopathogenesis of the disease

  5. Effect of sedation with detomidine and butorphanol on pulmonary gas exchange in the horse.

    Science.gov (United States)

    Nyman, Görel; Marntell, Stina; Edner, Anna; Funkquist, Pia; Morgan, Karin; Hedenstierna, Göran

    2009-05-07

    Sedation with alpha2-agonists in the horse is reported to be accompanied by impairment of arterial oxygenation. The present study was undertaken to investigate pulmonary gas exchange using the Multiple Inert Gas Elimination Technique (MIGET), during sedation with the alpha2-agonist detomidine alone and in combination with the opioid butorphanol. Seven Standardbred trotter horses aged 3-7 years and weighing 380-520 kg, were studied. The protocol consisted of three consecutive measurements; in the unsedated horse, after intravenous administration of detomidine (0.02 mg/kg) and after subsequent butorphanol administration (0.025 mg/kg). Pulmonary function and haemodynamic effects were investigated. The distribution of ventilation-perfusion ratios (VA/Q) was estimated with MIGET. During detomidine sedation, arterial oxygen tension (PaO2) decreased (12.8 +/- 0.7 to 10.8 +/- 1.2 kPa) and arterial carbon dioxide tension (PaCO2) increased (5.9 +/- 0.3 to 6.1 +/- 0.2 kPa) compared to measurements in the unsedated horse. Mismatch between ventilation and perfusion in the lungs was evident, but no increase in intrapulmonary shunt could be detected. Respiratory rate and minute ventilation did not change. Heart rate and cardiac output decreased, while pulmonary and systemic blood pressure and vascular resistance increased. Addition of butorphanol resulted in a significant decrease in ventilation and increase in PaCO2. Alveolar-arterial oxygen content difference P(A-a)O2 remained impaired after butorphanol administration, the VA/Q distribution improved as the decreased ventilation and persistent low blood flow was well matched. Also after subsequent butorphanol no increase in intrapulmonary shunt was evident. The results of the present study suggest that both pulmonary and cardiovascular factors contribute to the impaired pulmonary gas exchange during detomidine and butorphanol sedation in the horse.

  6. Effect of sedation with detomidine and butorphanol on pulmonary gas exchange in the horse

    Directory of Open Access Journals (Sweden)

    Morgan Karin

    2009-05-01

    Full Text Available Abstract Background Sedation with α2-agonists in the horse is reported to be accompanied by impairment of arterial oxygenation. The present study was undertaken to investigate pulmonary gas exchange using the Multiple Inert Gas Elimination Technique (MIGET, during sedation with the α2-agonist detomidine alone and in combination with the opioid butorphanol. Methods Seven Standardbred trotter horses aged 3–7 years and weighing 380–520 kg, were studied. The protocol consisted of three consecutive measurements; in the unsedated horse, after intravenous administration of detomidine (0.02 mg/kg and after subsequent butorphanol administration (0.025 mg/kg. Pulmonary function and haemodynamic effects were investigated. The distribution of ventilation-perfusion ratios (VA/Q was estimated with MIGET. Results During detomidine sedation, arterial oxygen tension (PaO2 decreased (12.8 ± 0.7 to 10.8 ± 1.2 kPa and arterial carbon dioxide tension (PaCO2 increased (5.9 ± 0.3 to 6.1 ± 0.2 kPa compared to measurements in the unsedated horse. Mismatch between ventilation and perfusion in the lungs was evident, but no increase in intrapulmonary shunt could be detected. Respiratory rate and minute ventilation did not change. Heart rate and cardiac output decreased, while pulmonary and systemic blood pressure and vascular resistance increased. Addition of butorphanol resulted in a significant decrease in ventilation and increase in PaCO2. Alveolar-arterial oxygen content difference P(A-aO2 remained impaired after butorphanol administration, the VA/Q distribution improved as the decreased ventilation and persistent low blood flow was well matched. Also after subsequent butorphanol no increase in intrapulmonary shunt was evident. Conclusion The results of the present study suggest that both pulmonary and cardiovascular factors contribute to the impaired pulmonary gas exchange during detomidine and butorphanol sedation in the horse.

  7. Growth, gas exchange, foliar nitrogen content, and water use of subirrigated and overhead irrigated Populus tremuloides Michx. seedlings

    Science.gov (United States)

    Anthony S. Davis; Matthew M. Aghai; Jeremiah R. Pinto; Kent G. Apostal

    2011-01-01

    Because limitations on water used by container nurseries has become commonplace, nursery growers will have to improve irrigation management. Subirrigation systems may provide an alternative to overhead irrigation systems by mitigating groundwater pollution and excessive water consumption. Seedling growth, gas exchange, leaf nitrogen (N) content, and water use were...

  8. Mechanisms underlying gas exchange alterations in an experimental model of pulmonary embolism

    Directory of Open Access Journals (Sweden)

    J.H.T. Ferreira

    2006-09-01

    Full Text Available The aim of the present study was to determine the ventilation/perfusion ratio that contributes to hypoxemia in pulmonary embolism by analyzing blood gases and volumetric capnography in a model of experimental acute pulmonary embolism. Pulmonary embolization with autologous blood clots was induced in seven pigs weighing 24.00 ± 0.6 kg, anesthetized and mechanically ventilated. Significant changes occurred from baseline to 20 min after embolization, such as reduction in oxygen partial pressures in arterial blood (from 87.71 ± 8.64 to 39.14 ± 6.77 mmHg and alveolar air (from 92.97 ± 2.14 to 63.91 ± 8.27 mmHg. The effective alveolar ventilation exhibited a significant reduction (from 199.62 ± 42.01 to 84.34 ± 44.13 consistent with the fall in alveolar gas volume that effectively participated in gas exchange. The relation between the alveolar ventilation that effectively participated in gas exchange and cardiac output (V Aeff/Q ratio also presented a significant reduction after embolization (from 0.96 ± 0.34 to 0.33 ± 0.17 fraction. The carbon dioxide partial pressure increased significantly in arterial blood (from 37.51 ± 1.71 to 60.76 ± 6.62 mmHg, but decreased significantly in exhaled air at the end of the respiratory cycle (from 35.57 ± 1.22 to 23.15 ± 8.24 mmHg. Exhaled air at the end of the respiratory cycle returned to baseline values 40 min after embolism. The arterial to alveolar carbon dioxide gradient increased significantly (from 1.94 ± 1.36 to 37.61 ± 12.79 mmHg, as also did the calculated alveolar (from 56.38 ± 22.47 to 178.09 ± 37.46 mL and physiological (from 0.37 ± 0.05 to 0.75 ± 0.10 fraction dead spaces. Based on our data, we conclude that the severe arterial hypoxemia observed in this experimental model may be attributed to the reduction of the V Aeff/Q ratio. We were also able to demonstrate that V Aeff/Q progressively improves after embolization, a fact attributed to the alveolar ventilation redistribution

  9. The Life Science Exchange: a case study of a sectoral and sub-sectoral knowledge exchange programme.

    Science.gov (United States)

    Perkins, Brian Lee; Garlick, Rob; Wren, Jodie; Smart, Jon; Kennedy, Julie; Stephens, Phil; Tudor, Gwyn; Bisson, Jonathan; Ford, David V

    2016-04-27

    Local and national governments have implemented sector-specific policies to support economic development through innovation, entrepreneurship and knowledge exchange. Supported by the Welsh Government through the European Regional Development Fund, The Life Science Exchange® project was created with the aim to increase interaction between stakeholders, to develop more effective knowledge exchange mechanisms, and to stimulate the formation and maintenance of long-term collaborative relationships within the Welsh life sciences ecosystem. The Life Science Exchange allowed participants to interact with other stakeholder communities (clinical, academic, business, governmental), exchange perspectives and discover new opportunities. Six sub-sector focus groups comprising over 200 senior stakeholders from academia, industry, the Welsh Government and National Health Service were established. Over 18 months, each focus group provided input to inform healthcare innovation policy and knowledge mapping exercises of their respective sub-sectors. Collaborative projects identified during the focus groups and stakeholder engagement were further developed through sandpit events and bespoke support. Each sub-sector focus group produced a report outlining the significant strengths and opportunities in their respective areas of focus, made recommendations to overcome any 'system failures', and identified the stakeholder groups which needed to take action. A second outcome was a stakeholder-driven knowledge mapping exercise for each area of focus. Finally, the sandpit events and bespoke support resulted in participants generating more than £1.66 million in grant funding and inward investment. This article outlines four separate outcomes from the Life Science Exchange programme. The Life Science Exchange process has resulted in a multitude of collaborations, projects, inward investment opportunities and special interest group formations, in addition to securing over ten times its own

  10. The Gas Sampling Interval Effect on V˙O2peak Is Independent of Exercise Protocol.

    Science.gov (United States)

    Scheadler, Cory M; Garver, Matthew J; Hanson, Nicholas J

    2017-09-01

    There is a plethora of gas sampling intervals available during cardiopulmonary exercise testing to measure peak oxygen consumption (V˙O2peak). Different intervals can lead to altered V˙O2peak. Whether differences are affected by the exercise protocol or subject sample is not clear. The purpose of this investigation was to determine whether V˙O2peak differed because of the manipulation of sampling intervals and whether differences were independent of the protocol and subject sample. The first subject sample (24 ± 3 yr; V˙O2peak via 15-breath moving averages: 56.2 ± 6.8 mL·kg·min) completed the Bruce and the self-paced V˙O2max protocols. The second subject sample (21.9 ± 2.7 yr; V˙O2peak via 15-breath moving averages: 54.2 ± 8.0 mL·kg·min) completed the Bruce and the modified Astrand protocols. V˙O2peak was identified using five sampling intervals: 15-s block averages, 30-s block averages, 15-breath block averages, 15-breath moving averages, and 30-s block averages aligned to the end of exercise. Differences in V˙O2peak between intervals were determined using repeated-measures ANOVAs. The influence of subject sample on the sampling effect was determined using independent t-tests. There was a significant main effect of sampling interval on V˙O2peak (first sample Bruce and self-paced V˙O2max P sample Bruce and modified Astrand P sampling intervals followed a similar pattern for each protocol and subject sample, with 15-breath moving average presenting the highest V˙O2peak. The effect of manipulating gas sampling intervals on V˙O2peak appears to be protocol and sample independent. These findings highlight our recommendation that the clinical and scientific community request and report the sampling interval whenever metabolic data are presented. The standardization of reporting would assist in the comparison of V˙O2peak.

  11. Isotope exchange reaction on solid breeder materials

    International Nuclear Information System (INIS)

    Baba, A.; Nishikawa, M.; Eguchi, T.; Kawagoe, T.

    2000-01-01

    Lithium ceramic materials such as Li 2 O, LiAlO 2 , Li 2 ZrO 3 , Li 2 TiO 3 and Li 4 SiO 4 are considered to be as candidate for the tritium breeding material in a deuterium-tritium (D-T) fusion reactor. In the recent blanket designs, helium gas with hydrogen or deuterium is planned to be used as the blanket purge gas to reduce tritium inventory and promote tritium release from the breeding material. In addition, the rate of isotope exchange reaction between hydrogen isotopes in the purge gas and tritium on the surface of the breeding material is necessary to analyze the tritium release behavior from the breeding materials. However, the rate of isotope exchange reactions between hydrogen isotopes in the purge gas and tritium on the surface of those materials has not been quantified until recently. Recently, the present authors quantified the rate of isotope exchange reaction on Li 2 O and Li 2 ZrO 3 . The overall mass transfer coefficients representing the isotope exchange reaction between H 2 and D 2 O on breeding materials or the same between D 2 and H 2 O are experimentally obtained in this study. Comparison to isotope exchange reaction rates on various breeding materials is also performed in this study. Discussions about the effects of temperature, concentration of hydrogen in the purge gas or flow rate of the purge gas on the conversion of tritiated water to tritium gas are also performed

  12. An investigation of heat exchanger fouling in dust suspension cooling systems using graphite powder and carbon dioxide gas

    International Nuclear Information System (INIS)

    Garton, D.A.; Hawes, R.I.; Rose, P.W.

    1966-01-01

    Some experiments have been performed to study the fouling of heat exchanger surfaces where heat is being transferred from a heated fluid to a cooled surface. The fluid studied was a suspension of 4-5 microns mean diameter graphite powder in carbon dioxide gas at near atmospheric pressures. The solids loading range covered was from 5 to 30 lb. graphite/lb. carbon dioxide, and gas Reynolds numbers from 6000 to 16000. Temperature gradients across the cooler of from 20 to 120 deg. C were obtained. The heat transfer ratio is correlated to show the dependence upon the solids loading ratio of the suspension, the gas Reynolds number and the temperature gradient across the cooler. The results have demonstrated that stringent precautions are necessary to ensure complete dryness of the graphite powder and the loop flow surfaces before any quantitative fouling data can be obtained, as the presence of entrained moisture will accelerate the deposition of material on the cold walls of the heat exchanger and can result in plugging. The heat transfer coefficient showed no obvious dependency upon either the gas Reynolds number or the temperature gradient across the cooler over the range investigated. The measured heat transfer coefficient was considerably lower than that obtained when the heat is transferred from a hot wall to a cooler fluid. At a solids loading of 30 lb, graphite/lb. carbon dioxide, the heat transfer coefficient was only 50% of that for heat transfer from a heated wall. At solids loadings below 7 lb/lb., the heat transfer was less than that for a gas alone. (author)

  13. Excess postexercise oxygen consumption is unaffected by the resistance and aerobic exercise order in an exercise session.

    Science.gov (United States)

    Oliveira, Norton L; Oliveira, Jose

    2011-10-01

    The main purpose of this study was to compare the magnitude and duration of excess postexercise oxygen consumption (EPOC) after 2 exercise sessions with different exercise mode orders, resistance followed by aerobic exercise (R-A); aerobic by resistance exercise (A-R). Seven young men (19.6 ± 1.4 years) randomly underwent the 2 sessions. Aerobic exercise was performed on a treadmill for 30 minutes (80-85% of reserve heart rate). Resistance exercise consisted of 3 sets of 10 repetition maximum on 5 exercises. Previous to the exercise sessions, V(O2), heart rate, V(CO2), and respiratory exchange rate (RER) were measured for 15 minutes and again during recovery from exercise for 60 minutes. The EPOC magnitude was not significantly different between R-A (5.17 ± 2.26 L) and A-R (5.23 ± 2.48 L). Throughout the recovery period (60 minutes), V(O2) and HR values were significantly higher than those observed in the pre-exercise period (p better to start a training session.

  14. Asymmetrical effects of mesophyll conductance on fundamental photosynthetic parameters and their relationships estimated from leaf gas exchange measurements

    Science.gov (United States)

    Most previous analyses of leaf gas exchange measurements assumed an infinite value of mesophyll conductance (gm) and thus equaled CO2 partial pressures in the substomatal cavity and chloroplast. Yet an increasing number of studies have recognized that gm is finite and there is a drawdown of CO2 part...

  15. A dynamic leaf gas-exchange strategy is conserved in woody plants under changing ambient CO2: evidence from carbon isotope discrimination in paleo and CO2 enrichment studies

    Science.gov (United States)

    Voelker, Steven L.; Brooks, J. Renée; Meinzer, Frederick C.; Anderson, Rebecca D.; Bader, Martin K.-F.; Battipaglia, Giovanna; Becklin, Katie M.; Beerling, David; Bert, Didier; Betancourt, Julio L.; Dawson, Todd E.; Domec, Jean-Christophe; Guyette, Richard P.; Körner, Christian; Leavitt, Steven W.; Linder, Sune; Marshall, John D.; Mildner, Manuel; Ogée, Jérôme; Panyushkina, Irina P.; Plumpton, Heather J.; Pregitzer, Kurt S.; Saurer, Matthias; Smith, Andrew R.; Siegwolf, Rolf T.W.; Stambaugh, Michael C.; Talhelm, Alan F.; Tardif, Jacques C.; Van De Water, Peter K.; Ward, Joy K.; Wingate, Lisa

    2016-01-01

    Rising atmospheric [CO2], ca, is expected to affect stomatal regulation of leaf gas-exchange of woody plants, thus influencing energy fluxes as well as carbon (C), water, and nutrient cycling of forests. Researchers have proposed various strategies for stomatal regulation of leaf gas-exchange that include maintaining a constant leaf internal [CO2], ci, a constant drawdown in CO2(ca − ci), and a constant ci/ca. These strategies can result in drastically different consequences for leaf gas-exchange. The accuracy of Earth systems models depends in part on assumptions about generalizable patterns in leaf gas-exchange responses to varying ca. The concept of optimal stomatal behavior, exemplified by woody plants shifting along a continuum of these strategies, provides a unifying framework for understanding leaf gas-exchange responses to ca. To assess leaf gas-exchange regulation strategies, we analyzed patterns in ci inferred from studies reporting C stable isotope ratios (δ13C) or photosynthetic discrimination (∆) in woody angiosperms and gymnosperms that grew across a range of ca spanning at least 100 ppm. Our results suggest that much of the ca-induced changes in ci/ca occurred across ca spanning 200 to 400 ppm. These patterns imply that ca − ci will eventually approach a constant level at high ca because assimilation rates will reach a maximum and stomatal conductance of each species should be constrained to some minimum level. These analyses are not consistent with canalization toward any single strategy, particularly maintaining a constant ci. Rather, the results are consistent with the existence of a broadly conserved pattern of stomatal optimization in woody angiosperms and gymnosperms. This results in trees being profligate water users at low ca, when additional water loss is small for each unit of C gain, and increasingly water-conservative at high ca, when photosystems are saturated and water loss is large for each unit C gain.

  16. Effect of Menthol on Respiratory and Perceptual Responses to Exercise in Firefighter Protective Gear

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2015-09-01

    Full Text Available Impaired respiration reduces firefighters’ work capacity. This study evaluated the effect of menthol lozenge on respiratory and perceptual responses during exercise in a hot environment. Ten participants wearing firefighter protective gear performed two repeated exercise and rest trials in a counter-balanced order. Exercise consisted of two bouts of 20-min treadmill exercise at 60% of maximal oxygen uptake and one bout of 20-min stepping exercise at a wet bulb global temperature of 35°C. Participants either took 10-mg menthol or control lozenges prior to the beginning of each exercise bout. Respiratory gas exchange, heart rate, thermal sensation, and breathing comfort were continuously recorded. Menthol lozenges significantly increased pulmonary ventilation (menthol: 45.0±6.6 L•min-1 vs. control: 41.4±5.8 L•min-1 and menthol: 52.7±9.7 L•min-1 vs. control: 46.5±7.0 L•min-1, for the 1st and 2nd treadmill exercise, respectively and oxygen consumption (menthol: 26.7±2.0 ml•kg-1•min-1 vs. control: 25.2±2.3 ml•kg-1•min-1 and menthol: 28.8±2.3 ml•kg-1•min-1 vs. control: 26.9±1.9 ml•kg-1•min-1, for the 1st and 2nd treadmill exercise, respe¬cti¬ve¬ly (p0.05. The ventilatory equivalents though were not different throughout the exercise (p>0.05. Ratings of thermal sensation and breathing comfort were not different (p>0.05. It was concluded that menthol could alter breathing pattern and increase respiratory responses during strenuous exercise in the heat. There was no favorable effect of menthol on respiratory or perceptual responses under exercise-heat stress.

  17. Intercomparison of radon gas detectors 1999 and 2000 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck, Gernot

    2000-10-01

    This report describes the results of two radon intercomparison exercises performed by the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut from Sep 9th to Oct 6th, 1999, and from March 21st to 28th, 2000. Radon gas detectors and instruments were exposed in the PSI Radon Chamber in reference atmospheres to 1060 kBqhm -3 radon gas exposure at an average radon gas concentration of 6400 Bqm -3 and to 2050 kBqhm -3 radon gas exposure at an average radon gas concentration of 12500 Bqm -3 , respectively. These intercomparison exercises determined the performance of electret ionisation chambers, track etch detectors and measuring instruments at high humidity (1999 Intercomparison Exercise) and at a high radon gas exposure (2000 Intercomparison Exercise). In the 1999 Intercomparison Exercise, electret ionisation chambers revealed an influence on high humidity. This effect may be due to impurities on a microscopic scale on the electrets of these detectors. With few exceptions, in both the 1999 and the 2000 Radon Intercomparison Exercise the deviations of the measurement results to the reference radon gas concentration values were less than 15% (traceability criterion) and the standard deviation of the results of five detectors less than 15% (reproducibility criterion). (author) [de

  18. Gas diffusion layer for proton exchange membrane fuel cells - A review

    Energy Technology Data Exchange (ETDEWEB)

    Cindrella, L. [Fuel Cell Research Laboratory, Department of Engineering Technology, Arizona State University, Mesa, AZ 85212 (United States); Department of Chemistry, National Institute of Technology, Tiruchirappalli 620015 (India); Kannan, A.M.; Lin, J.F.; Saminathan, K. [Fuel Cell Research Laboratory, Department of Engineering Technology, Arizona State University, Mesa, AZ 85212 (United States); Ho, Y. [Department of Biotechnology, College of Health Science, Asia University, Taichung 41354 (China); Lin, C.W. [Department of Chemical Engineering, National Yunlin University of Science and Technology, Yunlin 640 (China); Wertz, J. [Hollingsworth and Vose Co., A.K. Nicholson Research Lab, 219 Townsend Road, West Groton, MA 01472 (United States)

    2009-10-20

    Gas diffusion layer (GDL) is one of the critical components acting both as the functional as well as the support structure for membrane-electrode assembly in the proton exchange membrane fuel cell (PEMFC). The role of the GDL is very significant in the H{sub 2}/air PEM fuel cell to make it commercially viable. A bibliometric analysis of the publications on the GDLs since 1992 shows a total of 400+ publications (>140 papers in the Journal of Power Sources alone) and reveals an exponential growth due to reasons that PEMFC promises a lot of potential as the future energy source for varied applications and hence its vital component GDL requires due innovative analysis and research. This paper is an attempt to pool together the published work on the GDLs and also to review the essential properties of the GDLs, the method of achieving each one of them, their characterization and the current status and future directions. The optimization of the functional properties of the GDLs is possible only by understanding the role of its key parameters such as structure, porosity, hydrophobicity, hydrophilicity, gas permeability, transport properties, water management and the surface morphology. This paper discusses them in detail to provide an insight into the structural parts that make the GDLs and also the processes that occur in the GDLs under service conditions and the characteristic properties. The required balance in the properties of the GDLs to facilitate the counter current flow of the gas and water is highlighted through its characteristics. (author)

  19. Biomass and leaf-level gas exchange characteristics of three African savanna C4 grass species under optimum growth conditions

    NARCIS (Netherlands)

    Mantlana, K.B.; Veenendaal, E.M.; Arneth, A.; Grispen, V.; Bonyongo, C.M.; Heitkönig, I.M.A.; Lloyd, J.

    2009-01-01

    C4 savanna grass species, Digitaria eriantha, Eragrostis lehmanniana and Panicum repens, were grown under optimum growth conditions with the aim of characterizing their above- and below-ground biomass allocation and the response of their gas exchange to changes in light intensity, CO2 concentration

  20. Growth and gas exchange in white pitaya under different concentrations of potassium and calcium

    Directory of Open Access Journals (Sweden)

    João Paulo Cajazeira

    Full Text Available ABSTRACT Agriculture in Brazil has improved at a fast pace in recent years, given the growing demand for quality and the need for new products. In this respect, white pitaya [Hylocereus undatus (Haw. Britton & Rose] has become a feasible alternative for Northeast farmers. The limiting factors include a small amount of data on plant mineral nutrition and crop growth (phenology. Therefore, this study goal was to evaluate the effect of different concentrations of potassium (K and calcium (Ca on crop development and gas exchange in white pitaya grown in the coastal region of the state of Ceará, in Brazil. Sixteen treatments with three repetitions were organized in a completely randomized block design and a 4 × 4 factorial arrangement. Treatments consisted of various concentrations of K (0; 125; 250 and 375 mg dm-3 and Ca (0, 53, 106, and 159 mg dm-3. Biometric characteristics and gas exchange were determined after 270 and 240 days of treatment, respectively. For morphometric characteristics, the most significant nutrient combination was 250 mg dm-3 of K and 159 mg dm-3 of Ca. Net photosynthesis was higher at the dose of 125 mg dm-3 of K and 0 mg dm-3 of Ca. Our results indicate that, for the environmental conditions under which the test was conducted, an optimum nutrient combination for the analyzed variables was 250 mg dm-3 K and 159 mg dm-3 Ca.

  1. Quantitative variation in water-use efficiency across water regimes and its relationship with circadian, vegetative, reproductive, and leaf gas-exchange traits.

    Science.gov (United States)

    Edwards, Christine E; Ewers, Brent E; McClung, C Robertson; Lou, Ping; Weinig, Cynthia

    2012-05-01

    Drought limits light harvesting, resulting in lower plant growth and reproduction. One trait important for plant drought response is water-use efficiency (WUE). We investigated (1) how the joint genetic architecture of WUE, reproductive characters, and vegetative traits changed across drought and well-watered conditions, (2) whether traits with distinct developmental bases (e.g. leaf gas exchange versus reproduction) differed in the environmental sensitivity of their genetic architecture, and (3) whether quantitative variation in circadian period was related to drought response in Brassica rapa. Overall, WUE increased in drought, primarily because stomatal conductance, and thus water loss, declined more than carbon fixation. Genotypes with the highest WUE in drought expressed the lowest WUE in well-watered conditions, and had the largest vegetative and floral organs in both treatments. Thus, large changes in WUE enabled some genotypes to approach vegetative and reproductive trait optima across environments. The genetic architecture differed for gas-exchange and vegetative traits across drought and well-watered conditions, but not for floral traits. Correlations between circadian and leaf gas-exchange traits were significant but did not vary across treatments, indicating that circadian period affects physiological function regardless of water availability. These results suggest that WUE is important for drought tolerance in Brassica rapa and that artificial selection for increased WUE in drought will not result in maladaptive expression of other traits that are correlated with WUE.

  2. Estimating the effect of lung collapse and pulmonary shunt on gas exchange during breath-hold diving: the Scholander and Kooyman legacy.

    Science.gov (United States)

    Fahlman, A; Hooker, S K; Olszowka, A; Bostrom, B L; Jones, D R

    2009-01-01

    We developed a mathematical model to investigate the effect of lung compression and collapse (pulmonary shunt) on the uptake and removal of O(2), CO(2) and N(2) in blood and tissue of breath-hold diving mammals. We investigated the consequences of pressure (diving depth) and respiratory volume on pulmonary shunt and gas exchange as pressure compressed the alveoli. The model showed good agreement with previous studies of measured arterial O(2) tensions (Pa(O)(2)) from freely diving Weddell seals and measured arterial and venous N(2) tensions from captive elephant seals compressed in a hyperbaric chamber. Pulmonary compression resulted in a rapid spike in Pa(O)(2) and arterial CO(2) tension, followed by cyclical variation with a periodicity determined by Q(tot). The model showed that changes in diving lung volume are an efficient behavioural means to adjust the extent of gas exchange with depth. Differing models of lung compression and collapse depth caused major differences in blood and tissue N(2) estimates. Our integrated modelling approach contradicted predictions from simple models, and emphasised the complex nature of physiological interactions between circulation, lung compression and gas exchange. Overall, our work suggests the need for caution in interpretation of previous model results based on assumed collapse depths and all-or-nothing lung collapse models.

  3. HTO deposition through gas exchange between soil and atmosphere

    International Nuclear Information System (INIS)

    Feinhals, J.

    1988-06-01

    Theoretical considerations show that the ratio of HTO/H 2 O molecules, i.e. the specific activity, is not the same in atmospheric humidity and moisture absorption but differs by the so-called specific activity coefficient k. On this basis a computer model (ATHOS) was developed which allowed the calculation of both the surface contamination of the soil due to the gas exchange with a contaminated atmosphere and the depth-specific distribution of the soil acitvity. On the one hand the equations base on a modified Philip-de Vries theory, and on the other hand on a large number of soil column experiments which served the examination of the influence of parameters of microclimate and soil physics on the absorption and diffusion of tritiated water vapour under simulated conditions Above all the individual capability of each soil type to absorb moisture must be taken into consideration in connection with the HTO transfer. In this context theoretical and experimental examinations were carried out indicating a practice-related possibility to determine the soil-specific absorption capability. (orig./DG) [de

  4. Possible techniques for decontamination of natural gas from gas wells stimulated by a nuclear explosion

    Energy Technology Data Exchange (ETDEWEB)

    Wethington, Jr, John A [Lawrence Radiation Laboratory, University of California, Livermore, CA (United States)

    1970-05-15

    Decontamination of the products from gas wells stimulated by nuclear explosions requires the removal of T, present as HT, CH{sub 3}T, C{sub 2}H{sub 5}T, etc., and {sup 85}Kr from the production stream. Flaring of large volumes of gas from the Gasbuggy well led to the replacement of radioactive cavity gas with inactive formation gas, but this would not be a satisfactory production procedure because it releases T and {sup 85}Kr into the atmosphere and wastes large amounts of product gas. Exchange reactions appear to offer promise for removing the tritium. For example, water or steam flowing countercurrent to tritiated gas in the presence of a suitable catalyst can participate in the exchange reactions CH{sub 3}T + H{sub 2}O {r_reversible} CH{sub 4} + HTO, HT + H{sub 2}O {r_reversible} H{sub 2} + HTO, resulting in the transfer of T from gas into water. Other possibilities for utilizing exchange reactions include exchange of the gas with ethylene glycol used in the gas dryer, with silicate rocks introduced into the gas stream, or with a countercurrent stream of NH{sub 3} or H{sub 2}S. As another approach, use of the contaminated gas for the manufacture of ammonia synthesis gas has potential for removal of both T and {sup 85}Kr. (author)

  5. Modeling of the Process of Three-Isotope (H, D, T) Exchange Between Hydrogen Gas and Water Vapour on Pt-SDBC Catalyst over a Wide Range of Deuterium Concentration

    International Nuclear Information System (INIS)

    Fedorchenko, O.A.; Alekseev, I.A.; Tchijov, A.S.; Uborsky, V.V.

    2005-01-01

    The large scale studies of Combined Electrolysis and Catalytic Exchange (CECE) process in Petersburg Nuclear Physics Institute showed a complicated influence of various factors on the process caused by the presence of two simultaneous isotope exchange sub processes: counter-current phase exchange (between liquid water and water vapour) and co-current catalytic exchange (between hydrogen gas and water vapour). A laboratory scale set-up of glass made apparatuses was established in such a way that it allows us to study phase and catalytic exchange apart. A computer model of the set-up has been developed.The catalytic isotope exchange model formulation is presented. A collection of reversible chemical reactions is accompanied by diffusion of the gaseous reactants and reaction products in the pores of catalyst carrier. This has some interesting features that are demonstrated. Thus it was noted that the flow rates ratio (gas to vapour - λ = G/V) as well as the concentrations of reactants exert influence on the process efficiency

  6. Atmospheric concentrations and air–soil gas exchange of polycyclic aromatic hydrocarbons (PAHs) in remote, rural village and urban areas of Beijing–Tianjin region, North China

    Science.gov (United States)

    Wang, Wentao; Simonich, Staci; Giri, Basant; Chang, Ying; Zhang, Yuguang; Jia, Yuling; Tao, Shu; Wang, Rong; Wang, Bin; Li, Wei; Cao, Jun; Lu, Xiaoxia

    2013-01-01

    Forty passive air samplers were deployed to study the occurrence of gas and particulate phase PAHs in remote, rural village and urban areas of Beijing–Tianjin region, North China for four seasons (spring, summer, fall and winter) from 2007 to 2008. The influence of emissions on the spatial distribution pattern of air PAH concentrations was addressed. In addition, the air–soil gas exchange of PAHs was studied using fugacity calculations. The median gaseous and particulate phase PAH concentrations were 222 ng/m3 and 114 ng/m3, respectively, with a median total PAH concentration of 349 ng/m3. Higher PAH concentrations were measured in winter than in other seasons. Air PAH concentrations measured at the rural villages and urban sites in the northern mountain region were significantly lower than those measured at sites in the southern plain during all seasons. However, there was no significant difference in PAH concentrations between the rural villages and urban sites in the northern and southern areas. This urban–rural PAH distribution pattern was related to the location of PAH emission sources and the population distribution. The location of PAH emission sources explained 56%–77% of the spatial variation in ambient air PAH concentrations. The annual median air–soil gas exchange flux of PAHs was 42.2 ng/m2/day from soil to air. Among the 15 PAHs measured, acenaphthylene (ACY) and acenaphthene (ACE) contributed to more than half of the total exchange flux. Furthermore, the air–soil gas exchange fluxes of PAHs at the urban sites were higher than those at the remote and rural sites. In summer, more gaseous PAHs volatilized from soil to air because of higher temperatures and increased rainfall. However, in winter, more gaseous PAHs deposited from air to soil due to higher PAH emissions and lower temperatures. The soil TOC concentration had no significant influence on the air–soil gas exchange of PAHs. PMID:21669328

  7. Atmospheric concentrations and air-soil gas exchange of polycyclic aromatic hydrocarbons (PAHs) in remote, rural village and urban areas of Beijing-Tianjin region, North China.

    Science.gov (United States)

    Wang, Wentao; Simonich, Staci; Giri, Basant; Chang, Ying; Zhang, Yuguang; Jia, Yuling; Tao, Shu; Wang, Rong; Wang, Bin; Li, Wei; Cao, Jun; Lu, Xiaoxia

    2011-07-01

    Forty passive air samplers were deployed to study the occurrence of gas and particulate phase PAHs in remote, rural village and urban areas of Beijing-Tianjin region, North China for four seasons (spring, summer, fall and winter) from 2007 to 2008. The influence of emissions on the spatial distribution pattern of air PAH concentrations was addressed. In addition, the air-soil gas exchange of PAHs was studied using fugacity calculations. The median gaseous and particulate phase PAH concentrations were 222 ng/m³ and 114 ng/m³, respectively, with a median total PAH concentration of 349 ng/m³. Higher PAH concentrations were measured in winter than in other seasons. Air PAH concentrations measured at the rural villages and urban sites in the northern mountain region were significantly lower than those measured at sites in the southern plain during all seasons. However, there was no significant difference in PAH concentrations between the rural villages and urban sites in the northern and southern areas. This urban-rural PAH distribution pattern was related to the location of PAH emission sources and the population distribution. The location of PAH emission sources explained 56%-77% of the spatial variation in ambient air PAH concentrations. The annual median air-soil gas exchange flux of PAHs was 42.2 ng/m²/day from soil to air. Among the 15 PAHs measured, acenaphthylene (ACY) and acenaphthene (ACE) contributed to more than half of the total exchange flux. Furthermore, the air-soil gas exchange fluxes of PAHs at the urban sites were higher than those at the remote and rural sites. In summer, more gaseous PAHs volatilized from soil to air because of higher temperatures and increased rainfall. However, in winter, more gaseous PAHs deposited from air to soil due to higher PAH emissions and lower temperatures. The soil TOC concentration had no significant influence on the air-soil gas exchange of PAHs. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Intricate but tight coupling of spiracular activity and abdominal ventilation during locust discontinuous gas exchange cycles.

    Science.gov (United States)

    Talal, Stav; Gefen, Eran; Ayali, Amir

    2018-03-15

    Discontinuous gas exchange (DGE) is the best studied among insect gas exchange patterns. DGE cycles comprise three phases, which are defined by their spiracular state: closed, flutter and open. However, spiracle status has rarely been monitored directly; rather, it is often assumed based on CO 2 emission traces. In this study, we directly recorded electromyogram (EMG) signals from the closer muscle of the second thoracic spiracle and from abdominal ventilation muscles in a fully intact locust during DGE. Muscular activity was monitored simultaneously with CO 2 emission, under normoxia and under various experimental oxic conditions. Our findings indicate that locust DGE does not correspond well with the commonly described three-phase cycle. We describe unique DGE-related ventilation motor patterns, coupled to spiracular activity. During the open phase, when CO 2 emission rate is highest, the thoracic spiracles do not remain open; rather, they open and close rapidly. This fast spiracle activity coincides with in-phase abdominal ventilation, while alternating with the abdominal spiracle and thus facilitating a unidirectional air flow along the main trachea. A change in the frequency of rhythmic ventilation during the open phase suggests modulation by intra-tracheal CO 2 levels. A second, slow ventilatory movement pattern probably serves to facilitate gas diffusion during spiracle closure. Two flutter-like patterns are described in association with the different types of ventilatory activity. We offer a modified mechanistic model for DGE in actively ventilating insects, incorporating ventilatory behavior and changes in spiracle state. © 2018. Published by The Company of Biologists Ltd.

  9. High-Temperature Structural Analysis Model of the Process Heat Exchanger for Helium Gas Loop (II)

    International Nuclear Information System (INIS)

    Song, Kee Nam; Lee, Heong Yeon; Kim, Chan Soo; Hong, Seong Duk; Park, Hong Yoon

    2010-01-01

    PHE (Process Heat Exchanger) is a key component required to transfer heat energy of 950 .deg. C generated in a VHTR (Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established the helium gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype to be tested in the loop. In this study, as part of the high temperature structural-integrity evaluation of the PHE prototype, which is scheduled to be tested in the helium gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal expansion analysis of the PHE prototype. The results obtained in this study will be used to design the performance test setup for the PHE prototype

  10. The Respiratory Exchange Ratio is Associated with Fitness Indicators Both in Trained and Untrained Men: A Possible Application for People with Reduced Exercise Tolerance

    Directory of Open Access Journals (Sweden)

    Arnulfo Ramos-Jiménez

    2008-01-01

    Full Text Available Background The respiratory exchange ratio (RER indirectly shows the muscle's oxidative capacity to get energy. Sedentarism, exercise and physically active lifestyles modify it. For that reason, this study evaluates the associations between RER during sub-maximum exercise and other well established fitness indicators (body fat, maximum heart rate, maximum O 2 uptake, workload, and lactate threshold, in physically active trained and untrained men. Methods The RER, O 2 uptake and blood lactate were measured in eight endurance trained and eight untrained men (age, 22.9 ± 4.5 vs. 21.9 ± 2.8 years; body mass, 67.1 ± 5.4 vs. 72.2 ± 7.7 kg; body fat, 10.6 ± 2.4% vs. 16.6 ± 3.8% and maximum O2 uptake, 68.9 ± 6.3 vs. 51.6 ± 5.8 ml · kg −1 · min −1 , during maximum exercise test and during three different sub-maximum exercises at fixed workload: below, within or above the lactate threshold. Results Endurance trained men presented higher O 2 uptake, lower blood lactate concentrations and lower RER values than those in untrained men at the three similar relative workloads. Even though with these differences in RER, a strong association (p < 0.05 of RER during sub-maximum exercise with the other well established fitness indicators was observed, and both maximum O 2 uptake and lactate threshold determined more than 57% of its variance (p < 0.05. Conclusions These data demonstrate that RER measurement under sub-maximum exercise conditions was well correlated with other established physical fitness indicators, despite training condition. Furthermore, the results suggest that RER could help obtain an easy approach of fitness status under low exercise intensity and could be utilized in subjects with reduced exercise tolerance.

  11. Mycorrhizal stimulation of leaf gas exchange in relation to root colonization, shoot size, leaf phosphorus and nitrogen: a quantitative analysis of the literature using meta-regression

    Directory of Open Access Journals (Sweden)

    Robert M. Augé

    2016-07-01

    Full Text Available Arbuscular mycorrhizal (AM symbiosis often stimulates gas exchange rates of the host plant. This may relate to mycorrhizal effects on host nutrition and growth rate, or the influence may occur independently of these. Using meta-regression, we tested the strength of the relationship between AM-induced increases in gas exchange, and AM size and leaf mineral effects across the literature. With only a few exceptions, AM stimulation of carbon exchange rate (CER, stomatal conductance (gs and transpiration rate (E has been significantly associated with mycorrhizal stimulation of shoot dry weight, leaf phosphorus, leaf nitrogen: phosphorus ratio and percent root colonization. The sizeable mycorrhizal stimulation of CER, by 49% over all studies, has been about twice as large as the mycorrhizal stimulation of gs and E (28% and 26%, respectively. Carbon exchange rate has been over twice as sensitive as gs and four times as sensitive as E to mycorrhizal colonization rates. The AM-induced stimulation of CER increased by 19% with each AM-induced doubling of shoot size; the AM effect was about half as large for gs and E. The ratio of leaf N to leaf P has been more closely associated with mycorrhizal influence on leaf gas exchange than leaf P alone. The mycorrhizal influence on CER has declined markedly over the 35 years of published investigations.

  12. Phenotypic plasticity of gas exchange pattern and water loss in Scarabaeus spretus (Coleoptera: Scarabaeidae): deconstructing the basis for metabolic rate variation.

    Science.gov (United States)

    Terblanche, John S; Clusella-Trullas, Susana; Chown, Steven L

    2010-09-01

    Investigation of gas exchange patterns and modulation of metabolism provide insight into metabolic control systems and evolution in diverse terrestrial environments. Variation in metabolic rate in response to environmental conditions has been explained largely in the context of two contrasting hypotheses, namely metabolic depression in response to stressful or resource-(e.g. water) limited conditions, or elevation of metabolism at low temperatures to sustain life in extreme conditions. To deconstruct the basis for metabolic rate changes in response to temperature variation, here we undertake a full factorial study investigating the longer- and short-term effects of temperature exposure on gas exchange patterns. We examined responses of traits of gas exchange [standard metabolic rate (SMR); discontinuous gas exchange (DGE) cycle frequency; cuticular, respiratory and total water loss rate (WLR)] to elucidate the magnitude and form of plastic responses in the dung beetle, Scarabaeus spretus. Results showed that short- and longer-term temperature variation generally have significant effects on SMR and WLR. Overall, acclimation to increased temperature led to a decline in SMR (from 0.071+/-0.004 ml CO(2) h(-1) in 15 degrees C-acclimated beetles to 0.039+/-0.004 ml CO(2) h(-1) in 25 degrees C-acclimated beetles measured at 20 degrees C) modulated by reduced DGE frequency (15 degrees C acclimation: 0.554+/-0.027 mHz, 20 degrees C acclimation: 0.257+/-0.030 mHz, 25 degrees C acclimation: 0.208+/-0.027 mHz recorded at 20 degrees C), reduced cuticular WLRs (from 1.058+/-0.537 mg h(-1) in 15 degrees C-acclimated beetles to 0.900+/-0.400 mg h(-1) in 25 degrees C-acclimated beetles measured at 20 degrees C) and reduced total WLR (from 4.2+/-0.5 mg h(-1) in 15 degrees C-acclimated beetles to 3.1+/-0.5 mg h(-1) in 25 degrees C-acclimated beetles measured at 25 degrees C). Respiratory WLR was reduced from 2.25+/-0.40 mg h(-1) in 15 degrees C-acclimated beetles to 1.60+/-0.40 mg h

  13. The Effect of Water Stress on the Gas Exchange Parameters, Productivity and Seed Health of Buckwheat (Fagopyrum esculentum Moench

    Directory of Open Access Journals (Sweden)

    Agnieszka Pszczółkowska

    2012-12-01

    Full Text Available The present pot experiment studied the effect of different soil moisture contents (60 - 70% CWC (capillary water capacity - control; 30 - 35% CWC - water stress on buckwheat productivity, the gas exchange parameters and health of buckwheat nuts. It was found that water deficit affected adversely certain biometric features investigated (plant height, number of nuts per cluster and caused a decrease in seed weight per plant. It was also shown that water stress reduced the values of the investigated gas exchange parameters (photosynthesis rate, transpiration rate, intercellular-space CO2 concentration, and stomatal conductance relative to the control treatment. Different soil moisture contents did not have a clear effect on fungal colonization of seeds. The multiplex PCR assays did not enable the detection of the genes responsible for mycotoxin synthesis. Under water deficit conditions, an increase was found in the content of albumin and globulin fractions as well as of glutelin fractions.

  14. Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge

    International Nuclear Information System (INIS)

    Churchill, R. M.; Theiler, C.; Lipschultz, B.; Dux, R.; Pütterich, T.; Viezzer, E.

    2013-01-01

    A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique

  15. Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge

    Energy Technology Data Exchange (ETDEWEB)

    Churchill, R. M.; Theiler, C.; Lipschultz, B. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Dux, R.; Pütterich, T.; Viezzer, E. [Max-Planck-Institut für Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany); Collaboration: Alcator C-Mod Team; ASDEX Upgrade Team

    2013-09-15

    A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique.

  16. Whole Plant and Leaf Steady State Gas Exchange during Ethylene Exposure in Xanthium strumarium L.

    Science.gov (United States)

    Woodrow, L; Jiao, J; Tsujita, M J; Grodzinski, B

    1989-05-01

    The effects of ethylene evolved from ethephon on leaf and whole plant photosynthesis in Xanthium strumarium L. were examined. Ethylene-induced epinasty reduced light interception by the leaves of ethephon treated plants by up to 60%. Gas exchange values of individual, attached leaves under identical assay conditions were not inhibited even after 36 hours of ethylene exposure, although treated leaves required a longer induction period to achieve steady state photosynthesis. The speed of translocation of recently fixed (11)C-assimilate movement was not seriously impaired following ethephon treatment; however, a greater proportion of the assimilate was partitioned downward toward the roots. Within 24 hours of ethephon treatment, the whole plant net carbon exchange rate expressed on a per plant basis or a leaf area basis had dropped by 35%. The apparent inhibition of net carbon exchange rate was reversed by physically repositioning the leaves with respect to the light source. Ethylene exposure also inhibited expansion of young leaves which was partially reversed when the leaves were repositioned. The data indicated that ethylene indirectly affected net C gain and plant growth through modification of light interception and altered sink demand without directly inhibiting leaf photosynthesis.

  17. Nitrogen availability effects on gas exchange measurements in field-grown maize (Zea mays L.) under irrigated Mediterranean conditions

    Energy Technology Data Exchange (ETDEWEB)

    Isla, R.; Guillén, M.; Salmerón, M.

    2016-07-01

    There are limited studies about the effect of nitrogen (N) deficiency on leaf growth, N status, and photosynthetic capacity of maize grown under field conditions in a Mediterranean climate. The objective of this work was to evaluate the effect of different levels of mineral N availability on leaf gas exchange parameters of sprinkler irrigated maize. The experiment was conducted in a conventional maize field located in the central part of the Ebro valley (Spain) during two seasons. Using a portable LICOR-6400 equipment, instantaneous measurements and light response curves to gas exchange were conducted in plots with different levels of N supply ranging from deficient (no fertilized) to over-fertilized (300 kg N/ha). In addition to gas exchange measurements, mineral soil N content, chlorophyll meter readings (CMR), leaf N content, and grain yield were measured in the different plots. Results showed that grain yield reached a plateau (14.5 Mg/ha) when the mineral N available was about 179 kg/ha. CMR were linearly and highly related to total N in ear leaves. The relationship between light-saturated leaf photosynthesis measurements and CMR was significant but very weak (R2=0.13) at V8 and V14 stages but increased later in the growing season (R2=0.52). Plants with intermediate levels of N supply (48

  18. Nitrogen availability effects on gas exchange measurements in field-grown maize (Zea mays L.) under irrigated Mediterranean conditions

    International Nuclear Information System (INIS)

    Isla, R.; Guillén, M.; Salmerón, M.

    2016-01-01

    There are limited studies about the effect of nitrogen (N) deficiency on leaf growth, N status, and photosynthetic capacity of maize grown under field conditions in a Mediterranean climate. The objective of this work was to evaluate the effect of different levels of mineral N availability on leaf gas exchange parameters of sprinkler irrigated maize. The experiment was conducted in a conventional maize field located in the central part of the Ebro valley (Spain) during two seasons. Using a portable LICOR-6400 equipment, instantaneous measurements and light response curves to gas exchange were conducted in plots with different levels of N supply ranging from deficient (no fertilized) to over-fertilized (300 kg N/ha). In addition to gas exchange measurements, mineral soil N content, chlorophyll meter readings (CMR), leaf N content, and grain yield were measured in the different plots. Results showed that grain yield reached a plateau (14.5 Mg/ha) when the mineral N available was about 179 kg/ha. CMR were linearly and highly related to total N in ear leaves. The relationship between light-saturated leaf photosynthesis measurements and CMR was significant but very weak (R2=0.13) at V8 and V14 stages but increased later in the growing season (R2=0.52). Plants with intermediate levels of N supply (48< CMR<54) tended to have slightly higher assimilation rates than plants with higher CMR readings. As the available N increased, the saturation point, the light compensation point and significant increases of dark respiration rate were observed. Under the conditions of the study, leaf N contents of 1.9% in the ear leaf were enough to maximize leaf assimilation rates with no need to over-fertilize the maize crop.

  19. Discontinuous gas exchange in a tracheate arthropod, the pseudoscorpion Garypus californicus: Occurrence, characteristics and temperature dependence

    Directory of Open Access Journals (Sweden)

    John R.B. Lighton

    2002-11-01

    Full Text Available The discontinuous gas exchange cycle of the pseudoscorpion Garypus californicus, mean mass 5.9 mg, is rudimentary and is characterized by bursts of CO2 at frequencies ranging from 3.6 mHz at 15 °C to 13.3 mHz at 35 °C. The mean volume of CO2 emitted per burst is 3.6 µl g-1 at 25 °C, about a tenth of the amount emitted by tracheate arthropods with a well developed discontinuous gas exchange cycle. Interburst CO2 emission is high and increases with temperature, reaching near 45% of total CO2 production rate at 35 °C. No fluttering spiracle phase is evident. The metabolic rate of G. californicus at 25 °C (8.4 µW is typical of other arthropods. We infer from the high rate of interburst CO2 emission in G. californicus that trans-spiracular O2 partial pressure gradients are small and that spiracular conductance is correspondingly high, which may lead to high rates of respiratory water loss relative to arthropods with more stringent spiracular control and higher CO2 buffering capacity. The typical moist, hypogeal environments and small body sizes of pseudoscorpions correlate well with their respiratory physiology

  20. Externally fired gas turbine cycles with high temperature heat exchangers utilising Fe-based ODS alloy tubing

    International Nuclear Information System (INIS)

    Olsson, F.; Svensson, S.-A.; Duncan, R.

    2001-01-01

    This work is part of the BRITE / EuRAM Project 'Development of Torsional Grain Structures to Improve Biaxial Creep Performance of Fe-based ODS Alloy Tubing for Biomass Power Plant'. The main goal of this project is to heat exchanger tubes working at 1100 o C and above. The paper deals with design implications of a biomass power plant, using an indirectly fired gas turbine with a high temperature heat exchanger containing Fe-based ODS alloy tubing. In the current heat exchanger design, ODS alloy tubing is used in a radiant section, using a bayonet type tube arrangement. This enables the use of straight sections of ODS tubing and reduces the amount of material required. In order to assess the potential of the power plant system, thermodynamic calculations have been conducted. Both co-generation and condensing applications are studied and results so far indicate that the electrical efficiency is high, compared to values reached by conventional steam cycle power plants of the same size (approx. 5 MW e ). (author)

  1. LES of Gas Exchange in IC Engines

    Directory of Open Access Journals (Sweden)

    Mittal V.

    2013-10-01

    Full Text Available As engine technologies become increasingly complex and engines are driven to new operating points, understanding transient phenomena is important to ensure reliable engine operation. Unlike Reynolds Averaged Navier-Stokes (RANS studies that only provide cycle-averaged information, Large Eddy Simulation (LES studies are capable of simulating cycle-to-cycle dynamics. In this work, a finite difference based structured methodology for LES of IC engines is presented. This structured approach allows for an efficient mesh generation process and provides potential for higher order numerical accuracy. An efficient parallel scalable block decomposition is done to overcome the challenges associated with the low ratio of fluid elements to overall mesh elements. The motion of the valves and piston is handled using a dynamic cell blanking approach and the Arbitrary Lagrangian Eulerian (ALE method, respectively. Modified three-dimensional Navier-Stokes Characteristic Boundary Conditions (NSCBC are used in the simulation to prescribe conditions in the manifolds. The accuracy of the simulation framework is validated using various canonical configurations. Flow bench simulations of an axisymmetric configuration and an actual engine geometry are done with the LES methodology. Simulations of the gas exchange in an engine under motored conditions are also performed. Overall, good agreement is obtained with experiments for all the cases. Therefore, this framework can be used for LES of engine simulations. In the future, reactive LES simulations will be performed using this framework.

  2. Positive pressure ventilation with the open lung concept optimizes gas exchange and reduces ventilator-induced lung injury in newborn piglets

    NARCIS (Netherlands)

    van Kaam, Anton H.; de Jaegere, Anne; Haitsma, Jack J.; van Aalderen, Wim M.; Kok, Joke H.; Lachmann, Burkhard

    2003-01-01

    Previous studies demonstrated that high-frequency oscillatory ventilation using the open lung concept (OLC resulted in superior gas exchange and a reduction in ventilator-induced lung injury (VILI). We hypothesized that these beneficial effects could also be achieved by applying the OLC during

  3. Ion Mobility Spectrometry-Mass Spectrometry Coupled with Gas-Phase Hydrogen/Deuterium Exchange for Metabolomics Analyses

    Science.gov (United States)

    Maleki, Hossein; Karanji, Ahmad K.; Majuta, Sandra; Maurer, Megan M.; Valentine, Stephen J.

    2018-02-01

    Ion mobility spectrometry-mass spectrometry (IMS-MS) in combination with gas-phase hydrogen/deuterium exchange (HDX) and collision-induced dissociation (CID) is evaluated as an analytical method for small-molecule standard and mixture characterization. Experiments show that compound ions exhibit unique HDX reactivities that can be used to distinguish different species. Additionally, it is shown that gas-phase HDX kinetics can be exploited to provide even further distinguishing capabilities by using different partial pressures of reagent gas. The relative HDX reactivity of a wide variety of molecules is discussed in light of the various molecular structures. Additionally, hydrogen accessibility scoring (HAS) and HDX kinetics modeling of candidate ( in silico) ion structures is utilized to estimate the relative ion conformer populations giving rise to specific HDX behavior. These data interpretation methods are discussed with a focus on developing predictive tools for HDX behavior. Finally, an example is provided in which ion mobility information is supplemented with HDX reactivity data to aid identification efforts of compounds in a metabolite extract.

  4. Air-sea exchange and gas-particle partitioning of polycyclic aromatic hydrocarbons over the northwestern Pacific Ocean: Role of East Asian continental outflow

    Science.gov (United States)

    Wu, Z.; Guo, Z.

    2017-12-01

    We measured 15 parent polycyclic aromatic hydrocarbons (PAHs) in atmosphere and water during a research cruise from the East China Sea (ECS) to the northwestern Pacific Ocean (NWP) in the spring of 2015 to investigate the occurrence, air-sea gas exchange, and gas-particle partitioning of PAHs with a particular focus on the influence of East Asian continental outflow. The gaseous PAH composition and identification of sources were consistent with PAHs from the upwind area, indicating that the gaseous PAHs (three- to five-ring PAHs) were influenced by upwind land pollution. In addition, air-sea exchange fluxes of gaseous PAHs were estimated to be -54.2 to 107.4 ng m-2 d-1, and was indicative of variations of land-based PAH inputs. The logarithmic gas-particle partition coefficient (logKp) of PAHs regressed linearly against the logarithmic subcooled liquid vapor pressure, with a slope of -0.25. This was significantly larger than the theoretical value (-1), implying disequilibrium between the gaseous and particulate PAHs over the NWP. The non-equilibrium of PAH gas-particle partitioning was shielded from the volatilization of three-ring gaseous PAHs from seawater and lower soot concentrations in particular when the oceanic air masses prevailed. Modeling PAH absorption into organic matter and adsorption onto soot carbon revealed that the status of PAH gas-particle partitioning deviated more from the modeling Kp for oceanic air masses than those for continental air masses, which coincided with higher volatilization of three-ring PAHs and confirmed the influence of air-sea exchange. Meanwhile, significant linear regressions between logKp and logKoa (logKsa) for PAHs were observed for continental air masses, suggesting the dominant effect of East Asian continental outflow on atmospheric PAHs over the NWP during the sampling campaign.

  5. A hierarchy of factors influence discontinuous gas exchange in the grasshopper Paracinema tricolor (Orthoptera: Acrididae).

    Science.gov (United States)

    Groenewald, Berlizé; Chown, Steven L; Terblanche, John S

    2014-10-01

    The evolutionary origin and maintenance of discontinuous gas exchange (DGE) in tracheate arthropods are poorly understood and highly controversial. We investigated prioritization of abiotic factors in the gas exchange control cascade by examining oxygen, water and haemolymph pH regulation in the grasshopper Paracinema tricolor. Using a full-factorial design, grasshoppers were acclimated to hypoxic or hyperoxic (5% O2, 40% O2) gas conditions, or dehydrated or hydrated, whereafter their CO2 release was measured under a range of O2 and relative humidity (RH) conditions (5%, 21%, 40% O2 and 5%, 60%, 90% RH). DGE was significantly less common in grasshoppers acclimated to dehydrating conditions compared with the other acclimations (hypoxia, 98%; hyperoxia, 100%; hydrated, 100%; dehydrated, 67%). Acclimation to dehydrating conditions resulted in a significant decrease in haemolymph pH from 7.0±0.3 to 6.6±0.1 (mean ± s.d., P=0.018) and also significantly increased the open (O)-phase duration under 5% O2 treatment conditions (5% O2, 44.1±29.3 min; 40% O2, 15.8±8.0 min; 5% RH, 17.8±1.3 min; 60% RH, 24.0±9.7 min; 90% RH, 20.6±8.9 min). The observed acidosis could potentially explain the extension of the O-phase under low RH conditions, when it would perhaps seem more useful to reduce the O-phase to lower respiratory water loss. The results confirm that DGE occurrence and modulation are affected by multiple abiotic factors. A hierarchical framework for abiotic factors influencing DGE is proposed in which the following stressors are prioritized in decreasing order of importance: oxygen supply, CO2 excretion and pH modulation, oxidative damage protection and water savings. © 2014. Published by The Company of Biologists Ltd.

  6. Assessment of thermodynamic models for the design, analysis and optimisation of gas liquefaction systems

    DEFF Research Database (Denmark)

    Nguyen, Tuong-Van; Elmegaard, Brian

    2016-01-01

    of their performance. However, the thermodynamic models used for this purpose are characterised by different mathematical formulations, ranges of application and levels of accuracy. This may lead to inconsistent results when estimating hydrocarbon properties and assessing the efficiency of a given process. This paper...... are related to the prediction of the energy flows (up to 7%) and to the heat exchanger conductances (up to 11%), and they are not systematic errors. The results illustrate the superiority of using the GERG-2008 model for designing gas processes in real applications, with the aim of reducing their energy use....... They demonstrate as well that particular caution should be exercised when extrapolating the results of the conventional thermodynamic models to the actual conception of the gas liquefaction chain....

  7. Stomatal kinetics and photosynthetic gas exchange along a continuum of isohydric to anisohydric regulation of plant water status

    Science.gov (United States)

    Frederick C. Meinzer; Duncan D. Smith; David R. Woodruff; Danielle E. Marias; Katherine A. McCulloh; Ava R. Howard; Alicia L. Magedman

    2017-01-01

    Species’ differences in the stringency of stomatal control of plant water potential represent a continuum of isohydric to anisohydric behaviours. However, little is known about how quasi-steady-state stomatal regulation of water potential may relate to dynamic behaviour of stomata and photosynthetic gas exchange in species operating at different positions along this...

  8. Leaf gas exchange and nutrient use efficiency help explain the distribution of two Neotropical mangroves under contrasting flooding and salinity

    Science.gov (United States)

    Cardona-Olarte, Pablo; Krauss, Ken W.; Twilley, Robert R.

    2013-01-01

    Rhizophora mangle and Laguncularia racemosa co-occur along many intertidal floodplains in the Neotropics. Their patterns of dominance shift along various gradients, coincident with salinity, soil fertility, and tidal flooding. We used leaf gas exchange metrics to investigate the strategies of these two species in mixed culture to simulate competition under different salinity concentrations and hydroperiods. Semidiurnal tidal and permanent flooding hydroperiods at two constant salinity regimes (10 g L−1 and 40 g L−1) were simulated over 10 months. Assimilation (A), stomatal conductance (gw), intercellular CO2 concentration (Ci), instantaneous photosynthetic water use efficiency (PWUE), and photosynthetic nitrogen use efficiency (PNUE) were determined at the leaf level for both species over two time periods. Rhizophora mangle had significantly higher PWUE than did L. racemosa seedlings at low salinities; however, L. racemosa had higher PNUE and stomatal conductance and gw, accordingly, had greater intercellular CO2 (calculated) during measurements. Both species maintained similar capacities for assimilation at 10 and 40 g L−1 salinity and during both permanent and tidal hydroperiod treatments. Hydroperiod alone had no detectable effect on leaf gas exchange. However, PWUE increased and PNUE decreased for both species at 40 g L−1 salinity compared to 10 g L−1. At 40 g L−1 salinity, PNUE was higher for L. racemosa than R. mangle with tidal flooding. These treatments indicated that salinity influences gas exchange efficiency, might affect how gases are apportioned intercellularly, and accentuates different strategies for distributing leaf nitrogen to photosynthesis for these two species while growing competitively.

  9. Leaf Gas Exchange and Nutrient Use Efficiency Help Explain the Distribution of Two Neotropical Mangroves under Contrasting Flooding and Salinity

    Directory of Open Access Journals (Sweden)

    Pablo Cardona-Olarte

    2013-01-01

    Full Text Available Rhizophora mangle and Laguncularia racemosa cooccur along many intertidal floodplains in the Neotropics. Their patterns of dominance shift along various gradients, coincident with salinity, soil fertility, and tidal flooding. We used leaf gas exchange metrics to investigate the strategies of these two species in mixed culture to simulate competition under different salinity concentrations and hydroperiods. Semidiurnal tidal and permanent flooding hydroperiods at two constant salinity regimes (10 g L−1 and 40 g L−1 were simulated over 10 months. Assimilation (A, stomatal conductance (gw, intercellular CO2 concentration (Ci, instantaneous photosynthetic water use efficiency (PWUE, and photosynthetic nitrogen use efficiency (PNUE were determined at the leaf level for both species over two time periods. Rhizophora mangle had significantly higher PWUE than did L. racemosa seedlings at low salinities; however, L. racemosa had higher PNUE and gw and, accordingly, had greater intercellular CO2 (calculated during measurements. Both species maintained similar capacities for A at 10 and 40 g L−1 salinity and during both permanent and tidal hydroperiod treatments. Hydroperiod alone had no detectable effect on leaf gas exchange. However, PWUE increased and PNUE decreased for both species at 40 g L−1 salinity compared to 10 g L−1. At 40 g L−1 salinity, PNUE was higher for L. racemosa than R. mangle with tidal flooding. These treatments indicated that salinity influences gas exchange efficiency, might affect how gases are apportioned intercellularly, and accentuates different strategies for distributing leaf nitrogen to photosynthesis for these two species while growing competitively.

  10. Concept development of exchange liquid regeneration

    International Nuclear Information System (INIS)

    Mader, D.L.

    1985-08-01

    Concepts are described for regeneration of the intermediate liquid used for isotope exchange in indirect laser isotope separation processes where the laser operates on a process gas distinct from the feed stream. The specific case of regeneration of an exchange liquid consisting of water, sodium hydroxide, and dimethyl sulfoxide for a process to separate deuterium from hydrogen using laser irradiation of trifluoromethane gas is developed. A water feed stream is converted to steam which rises in a chemical process column where it redeuterates a descending flow of exchange liquid without causing significant changes in its chemical composition

  11. A fractal analytical model for the permeabilities of fibrous gas diffusion layer in proton exchange membrane fuel cells

    International Nuclear Information System (INIS)

    Xiao, Boqi; Fan, Jintu; Ding, Feng

    2014-01-01

    The study of water and gas transport through fibrous gas diffusion layer (GDL) is important to the optimization of proton exchange membrane fuel cells (PEMFCs). In this work, analytical models of dimensionless permeability, and water and gas relative permeabilities of fibrous GDL in PEMFCs are derived using fractal theory. In our models, the structure of fibrous GDL is characterized in terms of porosity, tortuosity fractal dimension (D T ), pore area fractal dimensions (d f ), water phase (d f,w ) and gas phase (d f,g ) fractal dimensions. The predicted dimensionless permeability, water and gas relative permeabilities based on the proposed models are in good agreement with experimental data and predictions of numerical simulations reported in the literature. The model reveals that, although water phase and gas phase fractal dimensions strongly depend on porosity, the water and gas relative permeabilities are independent of porosity and are a function of water saturation only. It is also shown that the dimensionless permeability decreases significantly with the increase of tortuosity fractal dimension. On the other hand, there is only a small decrease in the water and gas relative permeabilities when tortuosity fractal dimension increases. One advantage of the proposed analytical model is that it contains no empirical constant, which is normally required in past models

  12. Book Analysis of Arms and Insecurity in the Persian Gulf.

    Science.gov (United States)

    1988-04-01

    AND P. Exercise induced changes in blood ammonia levels in humans. Eur. VANAmEE. Respiratory alkalosis accompanying ammonia toxicity. J. AppL PhysioL...HA. to ensure uniform exercise intensity. Respiratory gas exchange and ventilation during ex- Submaximal Exercise ercise were measured using a...BTPS, 02 consumption (Vo 2) and CO2 group. Relative exercise intensity (%Vo, mx) was not production converted to STPD, and respiratory exchange

  13. Direct observations of Biogenic Volatile Organic Compound (BVOC) Air-Sea Exchange in the remote North Atlantic from the High-Wind Gas-Exchange Study (HiWinGS)

    Science.gov (United States)

    Kim, M.; Yang, M. X.; Blomquist, B.; Huebert, B. J.; Bertram, T. H.

    2014-12-01

    Biogenic Volatile Organic Compounds (BVOCs) are reactive trace gases that impact both chemistry and climate by regulating oxidant loadings, determining secondary organic aerosol production rates as well as altering particle hygroscopicity. While continental BVOC exchange rates are well studied, global marine flux estimates are poorly constrained. In Fall 2013, a chemical-ionization time-of-flight mass spectrometer (CI-ToF-MS) utilizing benzene cations was deployed as part of the High Wind Gas Exchange Study (HiWinGs) to quantify monoterpenes, isoprene and dimethylsulfide fluxes in the remote North Atlantic. Dimethylsulfide measurements are in strong agreement with those determined by the University of Hawaii's atmospheric pressure ionization mass-spectrometer. In the remote marine boundary layer, positive monoterpene fluxes (i.e. emissions) were observed while isoprene levels rarely exceeded the detection limit.

  14. Influence of Very High Breathing Resistance on Exercise Tolerance, Part 1 - Dry Exercise

    Science.gov (United States)

    2016-01-01

    endurance times. 15. SUBJECT TERMS control of breathing, ventilation, CO2, carbon dioxide, hypercapnia, CO2 retention , dyspnea, exercise, performance...to be near his exercise capacity , until the subject could no longer continue. Subjects were asked to give scores of Relative Perceived Exertion (RPE...span gas (5% CO2 and 16% O2 in nitrogen). The pressure transducer outputs were compared to a water manometer. Data analysis Breath by breath

  15. Quantification of regional early stage gas exchange changes using hyperpolarized {sup 129}Xe MRI in a rat model of radiation-induced lung injury

    Energy Technology Data Exchange (ETDEWEB)

    Doganay, Ozkan, E-mail: ozkan.doganay@oncology.ox.ac.uk [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ (United Kingdom); Stirrat, Elaine [Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8 (Canada); McKenzie, Charles [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Schulte, Rolf F. [General Electric Global Research, Munich 85748 (Germany); Santyr, Giles E. [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G1L7 (Canada)

    2016-05-15

    Purpose: To assess the feasibility of hyperpolarized (HP) {sup 129}Xe MRI for detection of early stage radiation-induced lung injury (RILI) in a rat model involving unilateral irradiation by assessing differences in gas exchange dynamics between irradiated and unirradiated lungs. Methods: The dynamics of gas exchange between alveolar air space and pulmonary tissue (PT), PT and red blood cells (RBCs) was measured using single-shot spiral iterative decomposition of water and fat with echo asymmetry and least-squares estimation images of the right and left lungs of two age-matched cohorts of Sprague Dawley rats. The first cohort (n = 5) received 18 Gy irradiation to the right lung using a {sup 60}Co source and the second cohort (n = 5) was not irradiated and served as the healthy control. Both groups were imaged two weeks following irradiation when radiation pneumonitis (RP) was expected to be present. The gas exchange data were fit to a theoretical gas exchange model to extract measurements of pulmonary tissue thickness (L{sub PT}) and relative blood volume (V{sub RBC}) from each of the right and left lungs of both cohorts. Following imaging, lung specimens were retrieved and percent tissue area (PTA) was assessed histologically to confirm RP and correlate with MRI measurements. Results: Statistically significant differences in L{sub PT} and V{sub RBC} were observed between the irradiated and non-irradiated cohorts. In particular, L{sub PT} of the right and left lungs was increased approximately 8.2% and 5.0% respectively in the irradiated cohort. Additionally, V{sub RBC} of the right and left lungs was decreased approximately 36.1% and 11.7% respectively for the irradiated cohort compared to the non-irradiated cohort. PTA measurements in both right and left lungs were increased in the irradiated group compared to the non-irradiated cohort for both the left (P < 0.05) and right lungs (P < 0.01) confirming the presence of RP. PTA measurements also correlated with the

  16. High altitude pulmonary edema and exercise at 4,400 meters on Mount McKinley. Effect of expiratory positive airway pressure.

    Science.gov (United States)

    Schoene, R B; Roach, R C; Hackett, P H; Harrison, G; Mills, W J

    1985-03-01

    Breathing against positive expiratory pressure has been used to improve gas exchange in many forms of pulmonary edema, and forced expiration against resistance during exercise has been advocated for climbing at high altitude as a method to optimize performance. To evaluate the effect of expiratory positive airway pressure (EPAP) on climbers with high altitude pulmonary edema (HAPE) and on exercise at high altitude, we studied four climbers with HAPE at rest and 13 healthy climbers during exercise on a bicycle ergometer at 4400 m. We measured minute ventilation (VI, L/min), arterial oxygen saturation (SaO2 percent), end-tidal carbon dioxide (PACO2, mm Hg), respiratory rate (RR), and heart rate (HR) during the last minute of a five minute interval at rest in the climbers with HAPE, and at rest, 300, and 600 kpm/minute workloads on a bicycle ergometer in the healthy subjects. The HAPE subjects demonstrated an increased SaO2 percent, no change in HR or VI, and a decrease in RR on EPAP as compared to control. In normal subjects, SaO2 percent, VI, and heart rate were significantly higher on EPAP 10 cm H2O than 0 cm H2O control (p less than 0.01, 0.01, and 0.05, respectively). The RR and PaCO2 were not significantly different. In summary, EPAP improves gas exchange in HAPE subjects at rest. The EPAP in normal subjects at high altitude resulted in a higher SaO2 percent at the expense of a higher VI and higher HR. These results suggest that the work of breathing is higher and the stroke volume lower on EPAP. The positive pressure mask may be an effective temporizing measure for victims of HAPE who cannot immediately go to a lower altitude.

  17. Homeostasis of exercise hyperpnea and optimal sensorimotor integration: the internal model paradigm.

    Science.gov (United States)

    Poon, Chi-Sang; Tin, Chung; Yu, Yunguo

    2007-10-15

    Homeostasis is a basic tenet of biomedicine and an open problem for many physiological control systems. Among them, none has been more extensively studied and intensely debated than the dilemma of exercise hyperpnea - a paradoxical homeostatic increase of respiratory ventilation that is geared to metabolic demands instead of the normal chemoreflex mechanism. Classical control theory has led to a plethora of "feedback/feedforward control" or "set point" hypotheses for homeostatic regulation, yet so far none of them has proved satisfactory in explaining exercise hyperpnea and its interactions with other respiratory inputs. Instead, the available evidence points to a far more sophisticated respiratory controller capable of integrating multiple afferent and efferent signals in adapting the ventilatory pattern toward optimality relative to conflicting homeostatic, energetic and other objectives. This optimality principle parsimoniously mimics exercise hyperpnea, chemoreflex and a host of characteristic respiratory responses to abnormal gas exchange or mechanical loading/unloading in health and in cardiopulmonary diseases - all without resorting to a feedforward "exercise stimulus". Rather, an emergent controller signal encoding the projected metabolic level is predicted by the principle as an exercise-induced 'mental percept' or 'internal model', presumably engendered by associative learning (operant conditioning or classical conditioning) which achieves optimality through continuous identification of, and adaptation to, the causal relationship between respiratory motor output and resultant chemical-mechanical afferent feedbacks. This internal model self-tuning adaptive control paradigm opens a new challenge and exciting opportunity for experimental and theoretical elucidations of the mechanisms of respiratory control - and of homeostatic regulation and sensorimotor integration in general.

  18. State sells oil and gas shares in Norway - Statoil to stock exchange list

    International Nuclear Information System (INIS)

    Kimpanpaeae, M.

    2001-01-01

    After several months debate the government of Norway has decided to sell parts of the national oil-company Staoil as well as state-owned gas and oil shares. The government has stated that in the first stage it would be possible to privatize 20% of the Statoil. The market value of Staoil in summer 1999 was estimated to 120 billion NOK and the value has been estimated to increase ever since. The same proposal includes selling 20% of the national oil and gas shares SDOEE. 15 % would be sold to Statoil before listing the company into the stock exchange and the rest to Norsk Hydro and other national and international companies. The remaining share, the value of which is about 500 billion NOK, will become a part of a new state-owned company. The oil and energy ministry of Norway has estimated that the market value of SDOEE is about 600 billion NOK. Advisory committee decided to increase the share to be sold of SDOEE to 21.5%, the share of other companies being 6.5%. SDOEE was grounded in 1985. Since then a part of the oil and gas income of Statoil has gone into the balances of Statoil and another part directly to the state. Statoil has been responsible for the oil and gas sales of SDOEE. SDOEE's gas and oil reserves have been estimated to be about 9.8 billion barrels, 35% of which is oil and the rest natural gas. A new independent state owned company will be founded for transport of natural gas as a part of the change process. Oil companies and other energy companies will deliver the natural gas also in the future. In addition to the national arrangements, the EU's gas market directive will lead to changes in the Norwegian gas sales. As a part of the European Economic Area Norway will put the EU's gas markets directive into force without any transition period. The directive will decrease the price of natural gas and hence the income of Norway from natural gas is estimated to decrease significantly. At the moment the sales company GFU is responsible for organizing the

  19. Leaf-level gas-exchange uniformity and photosynthetic capacity among loblolly pine (Pinus taeda L.) genotypes of contrasting inherent genetic variation

    Science.gov (United States)

    Michael J. Aspinwall; John S. King; Steven E. McKeand; Jean-Christophe Domec

    2011-01-01

    Variation in leaf-level gas exchange among widely planted genetically improved loblolly pine (Pinus taeda L.) genotypes could impact stand-level water use, carbon assimilation, biomass production, C allocation, ecosystem sustainability and biogeochemical cycling under changing environmental conditions. We examined uniformity in leaf-level light-saturated photosynthesis...

  20. Do chestnut, northern red, and white oak germinant seedlings respond similary to light treatments? II. Gas exchange and chlorophyll responses

    Science.gov (United States)

    Joanne Rebbeck; Amy Scherzer; Kurt. Gottschalk

    2012-01-01

    Understanding differences in physiological and growth strategies in low-light environments among upland oak species may help managers address the challenges of oaks' poor regeneration. Gas exchange and chlorophyll content were measured for northern red oak (Quercus rubra L.), chestnut oak (Quercus prinus L.), and white oak (...

  1. Water stress-induced modifications of leaf hydraulic architecture in sunflower: co-ordination with gas exchange.

    Science.gov (United States)

    Nardini, Andrea; Salleo, Sebastiano

    2005-12-01

    The hydraulic architecture, water relationships, and gas exchange of leaves of sunflower plants, grown under different levels of water stress, were measured. Plants were either irrigated with tap water (controls) or with PEG600 solutions with osmotic potential of -0.4 and -0.8 MPa (PEG04 and PEG08 plants, respectively). Mature leaves were measured for hydraulic resistance (R(leaf)) before and after making several cuts across minor veins, thus getting the hydraulic resistance of the venation system (R(venation)). R(leaf) was nearly the same in controls and PEG04 plants but it was reduced by about 30% in PEG08 plants. On the contrary, R(venation) was lowest in controls and increased in PEG04 and PEG08 plants as a likely result of reduction in the diameter of the veins' conduits. As a consequence, the contribution of R(venation) to the overall R(leaf) markedly increased from controls to PEG08 plants. Leaf conductance to water vapour (g(L)) was highest in controls and significantly lower in PEG04 and PEG08 plants. Moreover, g(L) was correlated to R(venation) and to leaf water potential (psi(leaf)) with highly significant linear relationships. It is concluded that water stress has an important effect on the hydraulic construction of leaves. This, in turn, might prove to be a crucial factor in plant-water relationships and gas exchange under water stress conditions.

  2. O2 uptake kinetics during exercise at peak O2 uptake.

    Science.gov (United States)

    Scheuermann, Barry W; Barstow, Thomas J

    2003-11-01

    Compared with moderate- and heavy-intensity exercise, the adjustment of O2 uptake (VO2) to exercise intensities that elicit peak VO2 has received relatively little attention. This study examined the VO2 response of 21 young, healthy subjects (25 +/- 6 yr; mean +/- SD) during cycle ergometer exercise to step transitions in work rate (WR) corresponding to 90, 100, and 110% of the peak WR achieved during a preliminary ramp protocol (15-30 W/min). Gas exchange was measured breath by breath and interpolated to 1-s values. VO2 kinetics were determined by use of a two- or three-component exponential model to isolate the time constant (tau2) as representative of VO2 kinetics and the amplitude (Amp) of the primary fast component independent of the appearance of any VO2 slow component. No difference in VO2 kinetics was observed between WRs (tau90 = 24.7 +/- 9.0; tau100 = 22.8 +/- 6.7; tau110 = 21.5 +/- 9.2 s, where subscripts denote percent of peak WR; P > 0.05); nor in a subgroup of eight subjects was tau2 different from the value for moderate-intensity (exercise (tau2 = 25 +/- 12 s, P > 0.05). As expected, the Amp increased with increasing WRs (Amp90 = 2,089 +/- 548; Amp100 = 2,165 +/- 517; Amp110 = 2,225 +/- 559 ml/min; Amp90 vs. Amp110, P exercise, the gain of the Vo2 response (as deltaVO2/DeltaWR) is reduced for exercise transitions in the severe-intensity domain, but the approach to this gain is well described by a common time constant that is invariant across work intensities. The lower deltaVO2/deltaWR may be due to an insufficient adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery to the exercising muscles or due to recruitment of motor units with lower oxidative capacity, after the onset of exercise in the severe-intensity domain.

  3. Noninvasive Assisted Ventilation in Pulmonary Gas Exchange Dysfunctions in Cardiac Surgical Patients

    Directory of Open Access Journals (Sweden)

    V. N. Poptsov

    2008-01-01

    Full Text Available Background. Postextubation pulmonary gas exchange dysfunctions are a potential complication in the activation of cardio-surgical patients in the early periods after surgical intervention. Objective: to evaluate the efficiency of noninvasive assisted ventilation (NIAV as a method for correcting the pulmonary gas exchange disturbances developing after early activation of cardiosurgical patients. Subjects and methods. The study included 64 patients (36 males and 28 females aged 21 to 72 (54±2 years who had been operated on under extracorporeal circulation (EC. The duration of EC and myocardial ischemia was 104±6 and 73±4 min, respectively. The indications for NIAV were the clinical manifestations of acute respiratory failure (ARF and/or PaCO2>50 mm Hg and/or PaO2/FiO2Results. During NIAV, there was improvement (p<0.05 of lung oxygenizing function (the increase in PaO2/FiO2 was 23%, a reduction in Qs/Qt from 21.1±1.9 to 13.9±1.0% (p<0.05. NIAV was accompanied by a decrease in PaCO2 (p<0.05. Hypercapnia regressed in 7 patients with isolated lung ventilatory dysfunction (PaCO2>50 mm Hg an hour after initiation of NIAV. During and after NIAV, there were reductions in right atrial pressure, mean pulmonary pressure, indexed total pulmonary vascular resistance (ITPVR (p<0.05. Prior to, during, and following NIAV, mean blood pressure, cardiac index, and indexed total pulmonary vascular resstance did not change greatly. In hypercapnia, the duration of NIAV was significantly less than that in lung oxygenizing function (2.8±0.2 hours versus 4.7±0.5 hours. That of ICU treatment was 23±4 hours. Fifty-two (81% patients were transferred from ICUs to cardiosurgical units on the following day after surgery. Conclusion. In most cases, NIAV promotes a rapid and effective correction of postextubation lung ventilatory and oxygenizing dysfunctions occurring after early activation of cardiosurgical patients. Key words: non-invasive assisted ventilation, early

  4. A two-dimensional microscale model of gas exchange during photosynthesis in maize (Zea mays L.) leaves.

    Science.gov (United States)

    Retta, Moges; Ho, Quang Tri; Yin, Xinyou; Verboven, Pieter; Berghuijs, Herman N C; Struik, Paul C; Nicolaï, Bart M

    2016-05-01

    CO2 exchange in leaves of maize (Zea mays L.) was examined using a microscale model of combined gas diffusion and C4 photosynthesis kinetics at the leaf tissue level. Based on a generalized scheme of photosynthesis in NADP-malic enzyme type C4 plants, the model accounted for CO2 diffusion in a leaf tissue, CO2 hydration and assimilation in mesophyll cells, CO2 release from decarboxylation of C4 acids, CO2 fixation in bundle sheath cells and CO2 retro-diffusion from bundle sheath cells. The transport equations were solved over a realistic 2-D geometry of the Kranz anatomy obtained from light microscopy images. The predicted responses of photosynthesis rate to changes in ambient CO2 and irradiance compared well with those obtained from gas exchange measurements. A sensitivity analysis showed that the CO2 permeability of the mesophyll-bundle sheath and airspace-mesophyll interfaces strongly affected the rate of photosynthesis and bundle sheath conductance. Carbonic anhydrase influenced the rate of photosynthesis, especially at low intercellular CO2 levels. In addition, the suberin layer at the exposed surface of the bundle sheath cells was found beneficial in reducing the retro-diffusion. The model may serve as a tool to investigate CO2 diffusion further in relation to the Kranz anatomy in C4 plants. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. De novo transcriptome analysis of pneumatophores (modified roots in the true mangrove species Avicennia marina and identification of the genes related to root gas exchange

    Directory of Open Access Journals (Sweden)

    Purushothaman Natarajan

    2017-10-01

    Full Text Available Mangroves plants which grow in estuaries naturally tolerate extreme conditions of high salinity (90 ppt and high light intensity. Avicennia marina is a true mangrove tree species with physiological adaptations like modified root system (pneumatophores and salt excretion glands in leaves as its one of the unique features to consider. The pneumatophores are a special type of roots with negative geotropism that project above the water surface or the level of flooded soils [1]. In contact with air these roots develop lenticels, which improve gas exchange between roots and environment [2]. In swamps and wetlands the presence of pneumatophores facilitates oxygen diffusion through the tissues, maintaining levels adequate for cellular respiration [3]. Objective of this study was to perform the whole transcriptome analysis of pneumatophore tissue of A. marina by Illumina sequencing and to identify putative genes involved in process of root gas exchange. We generated 19.73 million of paired-end reads and assembled into 86,856 unigenes with an average length of 772 bp. Further, annotation, tissue specific gene expression and genes related to root gas exchange will be presented.

  6. Study of the Bonham series representation of the Born--Oppenheimer exchange amplitude and the derivation of a local exchange potential

    International Nuclear Information System (INIS)

    Huo, W.M.

    1977-01-01

    The convergence and range of applicability of the Bonham series representation of the Born--Oppenheimer exchange amplitude is investigated. Numerical calculations on 1 1 S→2 3 S and 1 1 S→2 3 P of He by electron impact demonstrate that the first three terms of the Bonham series can provide an adequate representation of the Born--Oppenheimer amplitude from high energies down to near threshold. The three-term Bonham series is then used to represent the Hartree--Fock exchange kernel in momentum space, which has been shown by Lassettre to be proportional to the Born--Oppenheimer amplitude. Inverse Fourier transform, plus an additional approximation of replacing the momentum which appears as an expansion parameter in the Bonham series by its averge value, gives us a local exchange potential. If the averge momentum in the Thomas--Fermi model is used, the first term of the local exchange potential is just the electron gas exchange potential. A second term corresponding to a correction for the inhomogeneity in the electron gas density, is also obtained. No adjustable parameter is involved. Exchange energies of He, Be, and Ne calculated using the local exchange potential agree much better with the Hartree--Fock results than the electron gas model

  7. Protein and Peptide Gas-phase Structure Investigation Using Collision Cross Section Measurements and Hydrogen Deuterium Exchange

    Science.gov (United States)

    Khakinejad, Mahdiar

    Protein and peptide gas-phase structure analysis provides the opportunity to study these species outside of their explicit environment where the interaction network with surrounding molecules makes the analysis difficult [1]. Although gas-phase structure analysis offers a unique opportunity to study the intrinsic behavior of these biomolecules [2-4], proteins and peptides exhibit very low vapor pressures [2]. Peptide and protein ions can be rendered in the gas-phase using electrospray ionization (ESI) [5]. There is a growing body of literature that shows proteins and peptides can maintain solution structures during the process of ESI and these structures can persist for a few hundred milliseconds [6-9]. Techniques for monitoring gas-phase protein and peptide ion structures are categorized as physical probes and chemical probes. Collision cross section (CCS) measurement, being a physical probe, is a powerful method to investigate gas-phase structure size [3, 7, 10-15]; however, CCS values alone do not establish a one to one relation with structure(i.e., the CCS value is an orientationally averaged value [15-18]. Here we propose the utility of gas-phase hydrogen deuterium exchange (HDX) as a second criterion of structure elucidation. The proposed approach incudes extensive MD simulations to sample biomolecular ion conformation space with the production of numerous, random in-silico structures. Subsequently a CCS can be calculated for these structures and theoretical CCS values are compared with experimental values to produce a pool of candidate structures. Utilizing a chemical reaction model based on the gas-phase HDX mechanism, the HDX kinetics behavior of these candidate structures are predicted and compared to experimental results to nominate the best in-silico structures which match (chemically and physically) with experimental observations. For the predictive approach to succeed, an extensive technique and method development is essential. To combine CCS

  8. Diurnal and seasonal variation in air exchange rates and interzonal flows measured by active tracer gas in five Danish homes

    DEFF Research Database (Denmark)

    Clausen, Geo; Bekö, Gabriel; Toftum, Jørn

    2016-01-01

    We measured the air exchange rates (AER) in up to six rooms in five naturally ventilated dwellings across four seasons using active tracer gas. Night time AER was also estimated in all bedrooms based on occupant-generated CO2. Additionally, we studied the pollutant distribution across the dwellin...

  9. Whole Plant and Leaf Steady State Gas Exchange during Ethylene Exposure in Xanthium strumarium L. 1

    Science.gov (United States)

    Woodrow, Lorna; Jiao, Jirong; Tsujita, M. James; Grodzinski, Bernard

    1989-01-01

    The effects of ethylene evolved from ethephon on leaf and whole plant photosynthesis in Xanthium strumarium L. were examined. Ethylene-induced epinasty reduced light interception by the leaves of ethephon treated plants by up to 60%. Gas exchange values of individual, attached leaves under identical assay conditions were not inhibited even after 36 hours of ethylene exposure, although treated leaves required a longer induction period to achieve steady state photosynthesis. The speed of translocation of recently fixed 11C-assimilate movement was not seriously impaired following ethephon treatment; however, a greater proportion of the assimilate was partitioned downward toward the roots. Within 24 hours of ethephon treatment, the whole plant net carbon exchange rate expressed on a per plant basis or a leaf area basis had dropped by 35%. The apparent inhibition of net carbon exchange rate was reversed by physically repositioning the leaves with respect to the light source. Ethylene exposure also inhibited expansion of young leaves which was partially reversed when the leaves were repositioned. The data indicated that ethylene indirectly affected net C gain and plant growth through modification of light interception and altered sink demand without directly inhibiting leaf photosynthesis. Images Figure 1 PMID:16666773

  10. Leaf age affects the responses of foliar injury and gas exchange to tropospheric ozone in Prunus serotina seedlings

    International Nuclear Information System (INIS)

    Zhang Jianwei; Schaub, Marcus; Ferdinand, Jonathan A.; Skelly, John M.; Steiner, Kim C.; Savage, James E.

    2010-01-01

    We investigated the effect of leaf age on the response of net photosynthesis (A), stomatal conductance (g wv ), foliar injury, and leaf nitrogen concentration (N L ) to tropospheric ozone (O 3 ) on Prunus serotina seedlings grown in open-plots (AA) and open-top chambers, supplied with either carbon-filtered or non-filtered air. We found significant variation in A, g wv , foliar injury, and N L (P 3 treatments. Seedlings in AA showed the highest A and g wv due to relatively low vapor pressure deficit (VPD). Older leaves showed significantly lower A, g wv , N L , and higher foliar injury (P wv , and foliar injury to O 3 . Both VPD and N L had a strong influence on leaf gas exchange. Foliar O 3 -induced injury appeared when cumulative O 3 uptake reached 8-12 mmol m -2 , depending on soil water availability. The mechanistic assessment of O 3 -induced injury is a valuable approach for a biologically relevant O 3 risk assessment for forest trees. - Ozone effects on symptom development and leaf gas exchange interacted with leaf age and N-content on black cherry seedlings.

  11. Exercise Training During +Gz Acceleration

    Science.gov (United States)

    Greenleaf, J. E.; Chou, J. L.; Simonson, S. R.; Jackson, C. G. R.; Barnes, P. R.

    1999-01-01

    The overall purpose is to study the effect of passive (without exercise) and active (with exercise) +Gz (head-to-foot) acceleration training, using a short-arm (1.9m radius) centrifuge, on post- training maximal oxygen uptake (VO2 max, work capacity) and 70 deg head-up tilt (orthostatic) tolerance in ambulatory subjects to test the hypothesis that (a) both passive and active acceleration training will improve post-training tilt-tolerance, and (b) there will be no difference in tilt-tolerance between passive and active exercise acceleration training because increased hydrostatic and blood pressures, rather than increased muscular metabolism, will provide the major adaptive stimulus. The purpose of the pilot study was to test the hypothesis that there would be no significant difference in the metabolic responses (oxygen uptake, heart rate, pulmonary ventilation, or respiratory exchange ratio) during supine exercise with moderate +Gz acceleration.

  12. Improved arterial-ventricular coupling in metabolic syndrome after exercise training: a pilot study.

    Science.gov (United States)

    Fournier, Sara B; Donley, David A; Bonner, Daniel E; Devallance, Evan; Olfert, I Mark; Chantler, Paul D

    2015-01-01

    The metabolic syndrome (MetS) is associated with threefold increased risk of cardiovascular (CV) morbidity and mortality, which is partly due to a blunted CV reserve capacity, reflected by a reduced peak exercise left ventricular (LV) contractility and aerobic capacity and a blunted peak arterial-ventricular coupling. To date, no study has examined whether aerobic exercise training in MetS can reverse peak exercise CV dysfunction. Furthermore, examining how exercise training alters CV function in a group of individuals with MetS before the development of diabetes and/or overt CV disease can provide insights into whether some of the pathophysiological CV changes can be delayed/reversed, lowering their CV risk. The objective of this study was to examine the effects of 8 wk of aerobic exercise training in individuals with MetS on resting and peak exercise CV function. Twenty participants with MetS underwent either 8 wk of aerobic exercise training (MetS-ExT, n = 10) or remained sedentary (MetS-NonT, n = 10) during this period. Resting and peak exercise CV function was characterized using Doppler echocardiography and gas exchange. Exercise training did not alter resting LV diastolic or systolic function and arterial-ventricular coupling in MetS. In contrast, at peak exercise, an increase in LV contractility (40%, P < 0.01), cardiac output (28%, P < 0.05), and aerobic capacity (20%, P < 0.01), but a reduction in vascular resistance (30%, P < 0.05) and arterial-ventricular coupling (27%, P < 0.01), were noted in the MetS-ExT but not in the MetS-NonT group. Furthermore, an improvement in lifetime risk score was also noted in the MetS-ExT group. These findings have clinical importance because they provide insight that some of the pathophysiological changes associated with MetS can be improved and can lower the risk of CV disease.

  13. Exchange Rate Expectations, Currency Crises, and the Pricing of American Depositary Receipts

    OpenAIRE

    Eichler, Stefan

    2012-01-01

    I.1 Motivation Exchange rates are a key issue in international economics and politics. While the determinants of exchange rates have been extensively studied in previous works, this dissertation contributes to the literature by deriving exchange rate expectations from stock market (ADR) data and analyzing their determinants. This exercise is done for three cases where one has to resort to exchange rate expectations since the national exchange rate is either manipulated by the central bank...

  14. Quantification of regional early stage gas exchange changes using hyperpolarized "1"2"9Xe MRI in a rat model of radiation-induced lung injury

    International Nuclear Information System (INIS)

    Doganay, Ozkan; Stirrat, Elaine; McKenzie, Charles; Schulte, Rolf F.; Santyr, Giles E.

    2016-01-01

    Purpose: To assess the feasibility of hyperpolarized (HP) "1"2"9Xe MRI for detection of early stage radiation-induced lung injury (RILI) in a rat model involving unilateral irradiation by assessing differences in gas exchange dynamics between irradiated and unirradiated lungs. Methods: The dynamics of gas exchange between alveolar air space and pulmonary tissue (PT), PT and red blood cells (RBCs) was measured using single-shot spiral iterative decomposition of water and fat with echo asymmetry and least-squares estimation images of the right and left lungs of two age-matched cohorts of Sprague Dawley rats. The first cohort (n = 5) received 18 Gy irradiation to the right lung using a "6"0Co source and the second cohort (n = 5) was not irradiated and served as the healthy control. Both groups were imaged two weeks following irradiation when radiation pneumonitis (RP) was expected to be present. The gas exchange data were fit to a theoretical gas exchange model to extract measurements of pulmonary tissue thickness (L_P_T) and relative blood volume (V_R_B_C) from each of the right and left lungs of both cohorts. Following imaging, lung specimens were retrieved and percent tissue area (PTA) was assessed histologically to confirm RP and correlate with MRI measurements. Results: Statistically significant differences in L_P_T and V_R_B_C were observed between the irradiated and non-irradiated cohorts. In particular, L_P_T of the right and left lungs was increased approximately 8.2% and 5.0% respectively in the irradiated cohort. Additionally, V_R_B_C of the right and left lungs was decreased approximately 36.1% and 11.7% respectively for the irradiated cohort compared to the non-irradiated cohort. PTA measurements in both right and left lungs were increased in the irradiated group compared to the non-irradiated cohort for both the left (P < 0.05) and right lungs (P < 0.01) confirming the presence of RP. PTA measurements also correlated with the MRI measurements for both

  15. The study on water ingress mass in the steam generator heat-exchange tube rupture accident of modular high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Wang Yan; Shi Lei; Li Fu; Zheng Yanhua

    2012-01-01

    The steam generator heat-exchange tube rupture (SGTR) accident is an important and particular accident which will result in water ingress to the primary loop of reactor. Water ingress will result in chemical reaction of graphite fuel and structure with water, which may cause overpressure due to generation of explosive gaseous in large quantity. The study on the water ingress accident is significant for the verification of the inherent characteristics of high temperature gas-cooled reactor. The previous research shows that the amount of water ingress mass is the dominant key factor on the severity of the accident consequence. The 200 MWe high temperature gas-cooled reactor (HTR-PM), which is the first modular pebble-bed high temperature gas-cooled reactor in China designed by the Institute of Nuclear and New Energy Technology of Tsinghua University, is selected to be analyzed in this paper. The different DBA accident scenarios of double-ended break of single heat-exchange tube are simulated respectively by the thermal-hydraulic analysis code RETRAN-02. The results show the water ingress mass through the broken heat-exchange tube is related to the break location. The amount of water ingress mass is affected obviously by the capacity of the emptier system. With the balance of safety and economical efficiency, the amount of water ingress mass from the secondary side of steam generator into the primary coolant loop will be reduced by increasing properly the diameter of the draining lines. (authors)

  16. In vivo effects of Aphanizomenon flos-aquae DC-1 aphantoxins on gas exchange and ion equilibrium in the zebrafish gill

    International Nuclear Information System (INIS)

    Zhang, Delu; Liu, Siyi; Zhang, Jing; Zhang, Jian Kong; Hu, Chunxiang; Liu, Yongding

    2016-01-01

    Highlights: • Aphantoxins induce respiratory dysfunction in zebrafish gills. • Changes in LDH and cellular ultrastructure indicate gill damage. • Decreased NKA and CA reflect abnormal ion transport and gas exchange. • Increased ROS and decreased T-AOC suggest oxidative stress in the gills. - Abstract: Aphantoxins, neurotoxins or paralytic shellfish poisons (PSPs) generated by Aphanizomenon flos-aquae, are a threat to environmental safety and human health in eutrophic waters worldwide. The molecular mechanisms of neurotoxin function have been studied; however, the effects of these neurotoxins on oxidative stress, ion transport, gas exchange, and branchial ultrastructure in fish gills are not fully understood. Aphantoxins extracted from A. flos-aquae DC-1 were detected by high-performance liquid chromatography. The major ingredients were gonyautoxins 1 and 5 and neosaxitoxin, which comprised 34.04%, 21.28%, and 12.77% of the total, respectively. Zebrafish (Danio rerio) were administered A. flos-aquae DC-1 aphantoxins at 5.3 or 7.61 μg saxitoxin equivalents (eq)/kg (low and high doses, respectively) by intraperitoneal injection. The activities of Na"+-K"+-ATPase (NKA), carbonic anhydrase (CA), and lactate dehydrogenase (LDH), ultrastructural alterations in chloride and epithelial cells, and reactive oxygen species (ROS) and total antioxidative capacity (T-AOC) were investigated in the gills during the first 24 h after exposure. Aphantoxins significantly increased the level of ROS and decreased the T-AOC in zebrafish gills from 3 to 12 h post-exposure, suggesting an induction of oxidative stress and inhibition of antioxidant capacity. Reduced activities of NKA and CA demonstrated abnormal ion transport and gas exchange in the gills of aphantoxin-treated fish. Toxin administration also resulted in increased LDH activity and ultrastructural alterations in chloride and epithelial cells, suggesting a disruption of function and structure in zebrafish gills. The

  17. In vivo effects of Aphanizomenon flos-aquae DC-1 aphantoxins on gas exchange and ion equilibrium in the zebrafish gill

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Delu, E-mail: deluzh@163.com [Department of Lifescience and Biotechnology, College of Chemistry, Chemical Engineering and Life Sciences, Wuhan University of Technology, Wuhan 430070 (China); Liu, Siyi [Department of Lifescience and Biotechnology, College of Chemistry, Chemical Engineering and Life Sciences, Wuhan University of Technology, Wuhan 430070 (China); Zhang, Jing [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Zhang, Jian Kong [Department of Lifescience and Biotechnology, College of Chemistry, Chemical Engineering and Life Sciences, Wuhan University of Technology, Wuhan 430070 (China); Hu, Chunxiang, E-mail: deluzh@ihb.ac.cn [Key Laboratory of Algal Biology, Institute of Hydrobiology, The Chinese Academy of Sciences, Wuhan 430072 (China); Liu, Yongding [Key Laboratory of Algal Biology, Institute of Hydrobiology, The Chinese Academy of Sciences, Wuhan 430072 (China)

    2016-08-15

    Highlights: • Aphantoxins induce respiratory dysfunction in zebrafish gills. • Changes in LDH and cellular ultrastructure indicate gill damage. • Decreased NKA and CA reflect abnormal ion transport and gas exchange. • Increased ROS and decreased T-AOC suggest oxidative stress in the gills. - Abstract: Aphantoxins, neurotoxins or paralytic shellfish poisons (PSPs) generated by Aphanizomenon flos-aquae, are a threat to environmental safety and human health in eutrophic waters worldwide. The molecular mechanisms of neurotoxin function have been studied; however, the effects of these neurotoxins on oxidative stress, ion transport, gas exchange, and branchial ultrastructure in fish gills are not fully understood. Aphantoxins extracted from A. flos-aquae DC-1 were detected by high-performance liquid chromatography. The major ingredients were gonyautoxins 1 and 5 and neosaxitoxin, which comprised 34.04%, 21.28%, and 12.77% of the total, respectively. Zebrafish (Danio rerio) were administered A. flos-aquae DC-1 aphantoxins at 5.3 or 7.61 μg saxitoxin equivalents (eq)/kg (low and high doses, respectively) by intraperitoneal injection. The activities of Na{sup +}-K{sup +}-ATPase (NKA), carbonic anhydrase (CA), and lactate dehydrogenase (LDH), ultrastructural alterations in chloride and epithelial cells, and reactive oxygen species (ROS) and total antioxidative capacity (T-AOC) were investigated in the gills during the first 24 h after exposure. Aphantoxins significantly increased the level of ROS and decreased the T-AOC in zebrafish gills from 3 to 12 h post-exposure, suggesting an induction of oxidative stress and inhibition of antioxidant capacity. Reduced activities of NKA and CA demonstrated abnormal ion transport and gas exchange in the gills of aphantoxin-treated fish. Toxin administration also resulted in increased LDH activity and ultrastructural alterations in chloride and epithelial cells, suggesting a disruption of function and structure in zebrafish

  18. Biology and air–sea gas exchange controls on the distribution of carbon isotope ratios (δ13C in the ocean

    Directory of Open Access Journals (Sweden)

    A. Schmittner

    2013-09-01

    Full Text Available Analysis of observations and sensitivity experiments with a new three-dimensional global model of stable carbon isotope cycling elucidate processes that control the distribution of δ13C of dissolved inorganic carbon (DIC in the contemporary and preindustrial ocean. Biological fractionation and the sinking of isotopically light δ13C organic matter from the surface into the interior ocean leads to low δ13CDIC values at depths and in high latitude surface waters and high values in the upper ocean at low latitudes with maxima in the subtropics. Air–sea gas exchange has two effects. First, it acts to reduce the spatial gradients created by biology. Second, the associated temperature-dependent fractionation tends to increase (decrease δ13CDIC values of colder (warmer water, which generates gradients that oppose those arising from biology. Our model results suggest that both effects are similarly important in influencing surface and interior δ13CDIC distributions. However, since air–sea gas exchange is slow in the modern ocean, the biological effect dominates spatial δ13CDIC gradients both in the interior and at the surface, in contrast to conclusions from some previous studies. Calcium carbonate cycling, pH dependency of fractionation during air–sea gas exchange, and kinetic fractionation have minor effects on δ13CDIC. Accumulation of isotopically light carbon from anthropogenic fossil fuel burning has decreased the spatial variability of surface and deep δ13CDIC since the industrial revolution in our model simulations. Analysis of a new synthesis of δ13CDIC measurements from years 1990 to 2005 is used to quantify preformed and remineralized contributions as well as the effects of biology and air–sea gas exchange. The model reproduces major features of the observed large-scale distribution of δ13CDIC as well as the individual contributions and effects. Residual misfits are documented and analyzed. Simulated surface and subsurface

  19. Positive end-expiratory pressure improves gas exchange and pulmonary mechanics during partial liquid ventilation.

    Science.gov (United States)

    Kirmse, M; Fujino, Y; Hess, D; Kacmarek, R M

    1998-11-01

    Partial liquid ventilation (PLV) with perflubron (PFB) has been proposed as an adjunct to the current therapies for the acute respiratory distress syndrome (ARDS). Because PFB has been also referred to as "liquid PEEP," distributing to the most gravity-dependent regions of the lung, less attention has been paid to the amount of applied positive end-expiratory pressure (PEEP). We hypothesized that higher PEEP levels than currently applied are needed to optimize gas exchange, and that the lower inflection point (LIP) of the pressure-volume curve could be used to estimate the amount of PEEP needed when the lung is filled with PFB. Lung injury was induced in 23 sheep by repeated lung lavage with warmed saline until the PaO2/FIO2 ratio fell below 150. Five sheep were used to investigate the change of the LIP when the lung was filled with PFB in increments of 5 ml/kg/body weight to a total of 30 ml/kg/body weight. To evaluate the impact of PEEP set at LIP +1 cm H2O we randomized an additional 15 sheep to three groups with different doses (7.5 ml, 15 ml, 30 ml/kg/body weight) of PFB. In random order a PEEP of 5 cm H2O or PEEP at LIP +1 cm H2O was applied. The LIP decreased with incremental filling of PFB to a minimum at 10 ml (p PFB shifts the LIP to the left, and that setting PEEP at LIP +1 cm H2O improves gas exchange at moderate to high doses of PFB.

  20. Gas phase 1H NMR studies and kinetic modeling of dihydrogen isotope equilibration catalyzed by Ru-nanoparticles under normal conditions: dissociative vs. associative exchange.

    Science.gov (United States)

    Limbach, Hans-Heinrich; Pery, Tal; Rothermel, Niels; Chaudret, Bruno; Gutmann, Torsten; Buntkowsky, Gerd

    2018-04-25

    The equilibration of H2, HD and D2 between the gas phase and surface hydrides of solid organic-ligand-stabilized Ru metal nanoparticles has been studied by gas phase 1H NMR spectroscopy using closed NMR tubes as batch reactors at room temperature and 800 mbar. When two different nanoparticle systems, Ru/PVP (PVP ≡ polyvinylpyrrolidone) and Ru/HDA (HDA ≡ hexadecylamine) were exposed to D2 gas, only the release of HD from the hydride containing surface could be detected in the initial stages of the reaction, but no H2. In the case of Ru/HDA also the reverse experiment was performed where surface deuterated nanoparticles were exposed to H2. In that case, the conversion of H2 into gaseous HD was detected. In order to analyze the experimental kinetic and spectroscopic data, we explored two different mechanisms taking into account potential kinetic and equilibrium H/D isotope effects. Firstly, we explored the dissociative exchange mechanism consisting of dissociative adsorption of dihydrogen, fast hydride surface diffusion and associative desorption of dihydrogen. It is shown that if D2 is the reaction partner, only H2 will be released in the beginning of the reaction, and HD only in later reaction stages. The second mechanism, dubbed here associative exchange consists of the binding of dihydrogen to Ru surface atoms, followed by a H-transfer to or by H-exchange with an adjacent hydride site, and finally of the associative desorption of dihydrogen. In that case, in the exchange with D2, only HD will be released in the beginning of the reaction. Our experimental results are not compatible with the dissociative exchange but can be explained in terms of the associative exchange. Whereas the former will dominate at low temperatures and pressures, the latter will prevail around room temperature and normal pressures where transition metal nanoparticles are generally used as reaction catalysts.

  1. Standardized Elemental Basis for Gas-Turbine Engine Heat Exchangers is the Key Factor for Their Cost Reduction

    Institute of Scientific and Technical Information of China (English)

    Soudarev A.V; Soudarev B.V; Kondratiev V.V; Lazarev M.V

    2001-01-01

    The competitiveness of the small gas turbine units (GTUs) (Ne<300 kW) in the world power market is dependent on both the maintenance expenses and the capital costs of production. Reduction in the maintenance expenditures could be achieved by increasing the plant efficiency. This task could be solved by some methods: increasing the cycle inlet temperature TIT, getting the cycle more complex (use of heat regeneration and compressed air intermediate cooling), cutting the power consumption on heat-stressed parts cooling. Putting the above into effect is linked with introduction of novel structural materials, a sharp increase in the mass-size values and the plant manufacture expenditures, in particular, at provision of its self-regulation.In connection with the above, the development of the combined metal-ceramic airheaters and standardization of the elemental basis of the metal gas-gas heat exchangers will promote reduction in the expenditures of the maintenance and the manufacture of the small-size independent power GTEs.

  2. On the accuracy of instantaneous gas exchange rates, energy expenditure and respiratory quotient calculations obtained from indirect whole room calorimetry

    International Nuclear Information System (INIS)

    Gribok, Andrei; Rumpler, William; Hoyt, Reed; Buller, Mark

    2013-01-01

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause–effect relationship where the gaseous exchange rates representing the unknown causes need to be inferred from a known, noisy effect—gaseous concentrations. Two methods of such inference are analyzed. The first method is based on the previously published regularized deconvolution of the molar balance equation and the second one, proposed in this paper, relies on regularized differentiation of gaseous concentrations. It is found that both methods produce similar results for the absolute values of metabolic variables and their accuracy. The uncertainty for O 2 consumption rate is found to be 7% and for CO 2 production-–3.2%. The uncertainties in gaseous exchange rates do not depend on the absolute values of O 2 consumption and CO 2 production. In contrast, the absolute uncertainty in respiratory quotient is a function of the gaseous exchange rates and varies from 9.4% during the night to 2.3% during moderate exercise. The uncertainty in energy expenditure was found to be 5.9% and independent of the level of gaseous exchange. For both methods, closed form analytical formulas for confidence intervals are provided allowing quantification of uncertainty for four major metabolic variables in real world studies. (paper)

  3. On the accuracy of instantaneous gas exchange rates, energy expenditure and respiratory quotient calculations obtained from indirect whole room calorimetry.

    Science.gov (United States)

    Gribok, Andrei; Hoyt, Reed; Buller, Mark; Rumpler, William

    2013-06-01

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause-effect relationship where the gaseous exchange rates representing the unknown causes need to be inferred from a known, noisy effect-gaseous concentrations. Two methods of such inference are analyzed. The first method is based on the previously published regularized deconvolution of the molar balance equation and the second one, proposed in this paper, relies on regularized differentiation of gaseous concentrations. It is found that both methods produce similar results for the absolute values of metabolic variables and their accuracy. The uncertainty for O2 consumption rate is found to be 7% and for CO2 production--3.2%. The uncertainties in gaseous exchange rates do not depend on the absolute values of O2 consumption and CO2 production. In contrast, the absolute uncertainty in respiratory quotient is a function of the gaseous exchange rates and varies from 9.4% during the night to 2.3% during moderate exercise. The uncertainty in energy expenditure was found to be 5.9% and independent of the level of gaseous exchange. For both methods, closed form analytical formulas for confidence intervals are provided allowing quantification of uncertainty for four major metabolic variables in real world studies.

  4. Mycorrhizal Stimulation of Leaf Gas Exchange in Relation to Root Colonization, Shoot Size, Leaf Phosphorus and Nitrogen: A Quantitative Analysis of the Literature Using Meta-Regression.

    Science.gov (United States)

    Augé, Robert M; Toler, Heather D; Saxton, Arnold M

    2016-01-01

    Arbuscular mycorrhizal (AM) symbiosis often stimulates gas exchange rates of the host plant. This may relate to mycorrhizal effects on host nutrition and growth rate, or the influence may occur independently of these. Using meta-regression, we tested the strength of the relationship between AM-induced increases in gas exchange, and AM size and leaf mineral effects across the literature. With only a few exceptions, AM stimulation of carbon exchange rate (CER), stomatal conductance (g s), and transpiration rate (E) has been significantly associated with mycorrhizal stimulation of shoot dry weight, leaf phosphorus, leaf nitrogen:phosphorus ratio, and percent root colonization. The sizeable mycorrhizal stimulation of CER, by 49% over all studies, has been about twice as large as the mycorrhizal stimulation of g s and E (28 and 26%, respectively). CER has been over twice as sensitive as g s and four times as sensitive as E to mycorrhizal colonization rates. The AM-induced stimulation of CER increased by 19% with each AM-induced doubling of shoot size; the AM effect was about half as large for g s and E. The ratio of leaf N to leaf P has been more closely associated with mycorrhizal influence on leaf gas exchange than leaf P alone. The mycorrhizal influence on CER has declined markedly over the 35 years of published investigations.

  5. Using Noble Gas Measurements to Derive Air-Sea Process Information and Predict Physical Gas Saturations

    Science.gov (United States)

    Hamme, Roberta C.; Emerson, Steven R.; Severinghaus, Jeffrey P.; Long, Matthew C.; Yashayaev, Igor

    2017-10-01

    Dissolved gas distributions are important because they influence oceanic habitats and Earth's climate, yet competing controls by biology and physics make gas distributions challenging to predict. Bubble-mediated gas exchange, temperature change, and varying atmospheric pressure all push gases away from equilibrium. Here we use new noble gas measurements from the Labrador Sea to demonstrate a technique to quantify physical processes. Our analysis shows that water-mass formation can be represented by a quasi steady state in which bubble fluxes and cooling push gases away from equilibrium balanced by diffusive gas exchange forcing gases toward equilibrium. We quantify the rates of these physical processes from our measurements, allowing direct comparison to gas exchange parameterizations, and predict the physically driven saturation of other gases. This technique produces predictions that reasonably match N2/Ar observations and demonstrates that physical processes should force SF6 to be ˜6% more supersaturated than CFC-11 and CFC-12, impacting ventilation age calculations.

  6. Alterations of autonomic nervous activity and energy metabolism by capsaicin ingestion during aerobic exercise in healthy men.

    Science.gov (United States)

    Shin, Ki Ok; Moritani, Toshio

    2007-04-01

    We investigated whether capsaicin ingestion (150 mg) enhances substrate oxidation associated with thermogenic sympathetic activity as an energy metabolic modulator without causing prolongation of the cardiac OT interval during aerobic exercise in humans. Ten healthy males [24.4 (4.3) y] volunteered for this study. The cardiac autonomic nervous activities evaluated by means of heart rate variability of power spectral analysis, energy metabolism, and ECG QT interval were continuously measured during 5-min rest and 30-min exercise at 50% of maximal ventilatory threshold (50% VT(max)) on a stationary ergometer with placebo or capsaicin oral administration chosen at random. The results indicated that there were no significant differences in heart rate during rest or exercise between the two trials. Autonomic nervous activity increased in the capsaicin tablet trial during exercise, but the difference did not reach statistical significance. Capsaicin, however, significantly induced a lower respiratory gas exchange ratio [0.92 (0.02) vs. 0.94 (0.02), means (SE), p means (SE), p < 0.05] during exercise. On the other hand, the data on the cardiac OT interval showed no significant difference, indicating that oral administration of capsaicin did not cause any adverse effect on cardiac depolarization-repolarization. In conclusion, it may be considered that capsaicin consumption 1 h before low intensity exercise (50% VT(max)) is a valuable supplement for the treatment of individuals with hyperlipidemia and/or obesity because it improves lipolysis without any adverse effects on the cardiac depolarization and repolarization process.

  7. Low Cost Polymer heat Exchangers for Condensing Boilers

    Energy Technology Data Exchange (ETDEWEB)

    Butcher, Thomas [Brookhaven National Lab. (BNL), Upton, NY (United States); Trojanowski, Rebecca [Brookhaven National Lab. (BNL), Upton, NY (United States); Wei, George [Brookhaven National Lab. (BNL), Upton, NY (United States); Worek, Michael [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-30

    Work in this project sought to develop a suitable design for a low cost, corrosion resistant heat exchanger as part of a high efficiency condensing boiler. Based upon the design parameters and cost analysis several geometries and material options were explored. The project also quantified and demonstrated the durability of the selected polymer/filler composite under expected operating conditions. The core material idea included a polymer matrix with fillers for thermal conductivity improvement. While the work focused on conventional heating oil, this concept could also be applicable to natural gas, low sulfur heating oil, and biodiesel- although these are considered to be less challenging environments. An extruded polymer composite heat exchanger was designed, built, and tested during this project, demonstrating technical feasibility of this corrosion-resistant material approach. In such flue gas-to-air heat exchangers, the controlling resistance to heat transfer is in the gas-side convective layer and not in the tube material. For this reason, the lower thermal conductivity polymer composite heat exchanger can achieve overall heat transfer performance comparable to a metal heat exchanger. However, with the polymer composite, the surface temperature on the gas side will be higher, leading to a lower water vapor condensation rate.

  8. High temperature alloys and ceramic heat exchanger

    International Nuclear Information System (INIS)

    Okamoto, Masaharu

    1984-04-01

    From the standpoint of energy saving, the future operating temperatures of process heat and gas turbine plants will become higher. For this purpose, ceramics is the most promissing candidate material in strength for application to high-temperature heat exchangers. This report deals with a servey of characteristics of several high-temperature metallic materials and ceramics as temperature-resistant materials; including a servey of the state-of-the-art of ceramic heat exchanger technologies developed outside of Japan, and a study of their application to the intermediate heat exchanger of VHTR (a very-high-temperature gas-cooled reactor). (author)

  9. Effect of exercise on insulin action in human skeletal muscle

    DEFF Research Database (Denmark)

    Richter, Erik; Mikines, K J; Galbo, Henrik

    1989-01-01

    The effect of 1 h of dynamic one-legged exercise on insulin action in human muscle was studied in 6 healthy young men. Four hours after one-legged knee extensions, a three-step sequential euglycemic hyperinsulinemic clamp combined with arterial and bilateral femoral vein catheterization...... was performed. Increased insulin action on glucose uptake was found in the exercised compared with the rested thigh at mean plasma insulin concentrations of 23, 40, and 410 microU/ml. Furthermore, prior contractions directed glucose uptake toward glycogen synthesis and increased insulin effects on thigh O2...... consumption and at some insulin concentrations on potassium exchange. In contrast, no change in insulin effects on limb exchange of free fatty acids, glycerol, alanine or tyrosine were found after exercise. Glycogen concentration in rested vastus lateralis muscle did not increase measurably during the clamp...

  10. Air-sea exchange and gas-particle partitioning of polycyclic aromatic hydrocarbons over the northwestern Pacific Ocean: Role of East Asian continental outflow.

    Science.gov (United States)

    Wu, Zilan; Lin, Tian; Li, Zhongxia; Jiang, Yuqing; Li, Yuanyuan; Yao, Xiaohong; Gao, Huiwang; Guo, Zhigang

    2017-11-01

    We measured 15 parent polycyclic aromatic hydrocarbons (PAHs) in atmosphere and water during a research cruise from the East China Sea (ECS) to the northwestern Pacific Ocean (NWP) in the spring of 2015 to investigate the occurrence, air-sea gas exchange, and gas-particle partitioning of PAHs with a particular focus on the influence of East Asian continental outflow. The gaseous PAH composition and identification of sources were consistent with PAHs from the upwind area, indicating that the gaseous PAHs (three-to five-ring PAHs) were influenced by upwind land pollution. In addition, air-sea exchange fluxes of gaseous PAHs were estimated to be -54.2-107.4 ng m -2 d -1 , and was indicative of variations of land-based PAH inputs. The logarithmic gas-particle partition coefficient (logK p ) of PAHs regressed linearly against the logarithmic subcooled liquid vapor pressure (logP L 0 ), with a slope of -0.25. This was significantly larger than the theoretical value (-1), implying disequilibrium between the gaseous and particulate PAHs over the NWP. The non-equilibrium of PAH gas-particle partitioning was shielded from the volatilization of three-ring gaseous PAHs from seawater and lower soot concentrations in particular when the oceanic air masses prevailed. Modeling PAH absorption into organic matter and adsorption onto soot carbon revealed that the status of PAH gas-particle partitioning deviated more from the modeling K p for oceanic air masses than those for continental air masses, which coincided with higher volatilization of three-ring PAHs and confirmed the influence of air-sea exchange. Meanwhile, significant linear regressions between logK p and logK oa (logK sa ) for PAHs were observed for continental air masses, suggesting the dominant effect of East Asian continental outflow on atmospheric PAHs over the NWP during the sampling campaign. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Optimization of UA of heat exchangers and BOG compressor exit pressure of LNG boil-off gas reliquefaction system using exergy analysis

    Science.gov (United States)

    Kochunni, Sarun Kumar; Ghosh, Parthasarathi; Chowdhury, Kanchan

    2015-12-01

    Boil-off gas (BOG) generation and its handling are important issues in Liquefied natural gas (LNG) value chain because of economic, environment and safety reasons. Several variants of reliquefaction systems of BOG have been proposed by researchers. Thermodynamic analyses help to configure them and size their components for improving performance. In this paper, exergy analysis of reliquefaction system based on nitrogen-driven reverse Brayton cycle is carried out through simulation using Aspen Hysys 8.6®, a process simulator and the effects of heat exchanger size with and without related pressure drop and BOG compressor exit pressure are evaluated. Nondimensionalization of parameters with respect to the BOG load allows one to scale up or down the design. The process heat exchanger (PHX) requires much higher surface area than that of BOG condenser and it helps to reduce the quantity of methane vented out to atmosphere. As pressure drop destroys exergy, optimum UA of PHX decreases for highest system performance if pressure drop is taken into account. Again, for fixed sizes of heat exchangers, as there is a range of discharge pressures of BOG compressor at which the loss of methane in vent minimizes, the designer should consider choosing the pressure at lower value.

  12. Fabrication of gas diffusion layer based on x-y robotic spraying technique for proton exchange membrane fuel cell application

    International Nuclear Information System (INIS)

    Sitanggang, Ramli; Mohamad, Abu Bakar; Daud, Wan Ramli Wan; Kadhum, Abdul Amir H.; Iyuke, S.E.

    2009-01-01

    The x-y robotic spraying technique developed in the Universiti Kebangsaan Malaysia is capable of fabricating various sizes of thickness and porosity of gas diffusion layer (GDL) used in the proton exchange membrane fuel cell (PEMFC). These parameters are obtained by varying the characteristic spray numbers of the robotic spraying machine. This investigation results were adequately represented with mathematical equations for hydrogen gas distribution in GDL. Volumetric modulus (M) parameter is used to determine the value of current density produced on the electrode of a single cell PEMFC. Thus the M parameter can be employed as indicator for a successful GDL fabrication. GDL type 4 has three variables of layer design that can be optimized to function as gas distributor, gas storage, flooding preventer on GDL surface, to evacuate water from the electrode and to control the electrical conductivity. The gas distribution in GDL was mathematically represented with average error of 15.5%. The M value of GDL type 4 according to the model was 0.22 cm 3 /s and yielded a current density of 750 A/m 2 .

  13. Measuring the hydrogen/deuterium exchange of proteins at high spatial resolution by mass spectrometry: overcoming gas-phase hydrogen/deuterium scrambling.

    Science.gov (United States)

    Rand, Kasper D; Zehl, Martin; Jørgensen, Thomas J D

    2014-10-21

    acidic conditions where the amide hydrogen exchange rate is slowed by many orders of magnitude). The ability to localize the individual deuterated residues (the spatial resolution) is determined by the size (typically ∼7-15 residues) and the number of peptic peptides. These peptides provide a relatively coarse-grained picture of the protein dynamics. A fundamental understanding of the relationship between protein function/dysfunction and conformational dynamics requires in many cases higher resolution and ultimately single-residue resolution. In this Account, we summarize our efforts to achieve single-residue deuterium levels in proteins by electron-based or laser-induced gas-phase fragmentation methods. A crucial analytical requirement for this approach is that the pattern of deuterium labeling from solution is retained in the gas-phase fragment ions. It is therefore essential to control and minimize any occurrence of gas-phase randomization of the solution deuterium label (H/D scrambling) during the MS experiment. For this purpose, we have developed model peptide probes to accurately measure the onset and extent of H/D scrambling. Our analytical procedures to control the occurrence of H/D scrambling are detailed along with the physical parameters that induce it during MS analysis. In light of the growing use of gas-phase dissociation experiments to measure the HDX of proteins in order to obtain a detailed characterization and understanding of the dynamic conformations and interactions of proteins at the molecular level, we discuss the perspectives and challenges of future high-resolution HDX-MS methodology.

  14. Changes in pulmonary blood flow do not affect gas exchange during intermittent ventilation in resting turtles

    DEFF Research Database (Denmark)

    Wang, Tobias; Hicks, James W.

    2008-01-01

    The breathing pattern of many different air-breathing vertebrates, including lungfish, anuran amphibians, turtles, crocodiles and snakes, is characterized by brief periods of lung ventilation interspersed among apnoeas of variable duration. These intermittent ventilatory cycles are associated...... experimentally. The present study measured pulmonary gas exchange in fully recovered, freely diving turtles, where changes in pulmonary blood flow were prevented by partial occlusion of the pulmonary artery. Prevention of L-R shunt during ventilation did not impair CO2 excretion and overall, oxygen uptake and CO...

  15. Effects of Salinity Stress on Gas Exchange, Growth, and Nutrient Concentrations of Two Citrus Rootstocks

    Directory of Open Access Journals (Sweden)

    D. Khoshbakht

    2015-03-01

    Full Text Available A greenhouse study was undertaken to assess the salt tolerance of two citrus rootstocks, namely, Bakraii (Citrus sp. and Trifoliate orange (Poncirus trifoliata. A factorial experiment through a completely randomized design (CRD with three replications and four levels of salt including 0, 20, 40 and 60 mM NaCl was conducted. After eight weeks of treatment, number of leaves, plant height, leaf area, wet and dry weight of leaf, stem and root, length of root, chlorophyll content, net CO2 assimilation rate (ACO2, stomatal conductance (gs, transpiration (E and water use efficiency (WUE and ion concentrations were measured. Salinity decreased growth and net gas exchange. Trifoliate orange showed the most decrease in growth indices and net gas exchange compared with Bakraii. The ability to limit the transfer of sodium to leaves in low levels of salt was observed in Trifoliate orange, but this ability was not observed in high levels of salt. Results showed that accumulation of chloride in leaves and roots were less in Bakraii compared to the Trifoliate orange. The lower Cl- concentration in leaves of Bakraii than trifoliate orange suggests that the salinity tolerance of Bakraii is associated with less transport of Cl- to the leaves. Salinity increased K+ and decreased Mg2+ and Ca2+ concentrations in leaves of both rootstocks. It is proposed that salt stress effect on plant physiological processes such as changes in plant growth, Cl- and Na+ toxicity, and mineral distribution, decreases chlorophyll content and reduces the photosynthetic efficiency of these citrus species.

  16. Heat exchange apparatus

    International Nuclear Information System (INIS)

    Thurston, G.C.; McDaniels, J.D.; Gertsch, P.R.

    1979-01-01

    The present invention relates to heat exchangers used for transferring heat from the gas cooled core of a nuclear reactor to a secondary medium during standby and emergency conditions. The construction of the heat exchanger described is such that there is a minimum of welds exposed to the reactor coolant, the parasitic heat loss during normal operation of the reactor is minimized and the welds and heat transfer tubes are easily inspectable. (UK)

  17. Experimental and numerical investigation of gas side particulate fouling onto heat exchanger tubes

    International Nuclear Information System (INIS)

    Bailer, Frederic

    1998-01-01

    This work deals with gas side particulate fouling onto heat exchanger tubes. An experimental and numerical investigation was carried out. By means of a new testing loop designed for this study, the deposit kinetics were obtained in dust-controlled conditions at the beginning of the fouling process. Experimental results pointed out the existence of various transport regimes: for sub-micronic particles, convective diffusion augmented by thermophoresis in the presence of a temperature gradient governs the particle deposition; inertial impaction controls the super-micronic particles deposition: in the intermediate granulometric range, combined action of particle inertia and thermophoresis must be considered. Moreover, measurements on an other testing loop using a more concentrated aerosol allowed us to point out the modification of the mechanisms with time and the influence of the deposit shape. A numerical model predicting the particle deposition, based on the TRIO software and an Eulerian-Lagrangian approach, was developed and validated against experimental results from the literature and from our study. Numerical approach gave us an accurate understanding of the phenomena by means of local parameters computations. In this way, the different mechanisms which control particulate deposition onto heat exchangers tubes were identified and modelled, especially before the onset of the inertial impaction. (author) [fr

  18. Exercise reveals impairments in left ventricular systolic function in patients with metabolic syndrome.

    Science.gov (United States)

    Fournier, Sara B; Reger, Brian L; Donley, David A; Bonner, Daniel E; Warden, Bradford E; Gharib, Wissam; Failinger, Conard F; Olfert, Melissa D; Frisbee, Jefferson C; Olfert, I Mark; Chantler, Paul D

    2014-01-01

    Metabolic syndrome (MetS) is the manifestation of a cluster of cardiovascular risk factors and is associated with a threefold increase in the risk of cardiovascular morbidity and mortality, which is suggested to be mediated, in part, by resting left ventricular (LV) systolic dysfunction. However, to what extent resting LV systolic function is impaired in MetS is controversial, and there are no data indicating whether LV systolic function is impaired during exercise. Accordingly, the objective of this study was to examine comprehensively the LV and arterial responses to exercise in individuals with MetS without diabetes and/or overt cardiovascular disease in comparison to a healthy control population. Cardiovascular function was characterized using Doppler echocardiography and gas exchange in individuals with MetS (n = 27) versus healthy control subjects (n = 20) at rest and during peak exercise. At rest, individuals with MetS displayed normal LV systolic function but reduced LV diastolic function compared with healthy control subjects. During peak exercise, individuals with MetS had impaired contractility, pump performance and vasodilator reserve capacity versus control subjects. A blunted contractile reserve response resulted in diminished arterial-ventricular coupling reserve and limited aerobic capacity in individuals with MetS versus control subjects. These findings are of clinical importance, because they provide insight into the pathophysiological changes in MetS that may predispose this population of individuals to an increased risk of cardiovascular morbidity and mortality.

  19. Lower Secondary School Students' Attitudes Toward Computer-Supported Laboratory Exercises

    Directory of Open Access Journals (Sweden)

    Andreja Špernjak

    2010-03-01

    Full Text Available In Science teaching laboratory work is recognized as one of the cornerstones. In school science laboratory work computers can be used as computer supported laboratory (real and as virtual laboratory. In the first case “real” laboratories involve bench top experiments utilizing data acquisition systems while “virtual” laboratory entails interactive simulations and animations. Lower secondary school students in age between 11 and 15 performed three laboratory exercises (Activity of yeast, Gas exchange in breathing, Heart rate as classic, computer-supported and virtual laboratory. As a result of testing we know that all three methods are suitable even for younger students. When they were asked which method they liked the most, their first choice was computer-supported laboratory, followed by classic laboratory, and virtual laboratory at the end. Additionally recognized weak and strong sides of used methods are discussed.

  20. Gas-phase fragmentation of peptides to increase the spatial resolution of the Hydrogen Exchange Mass Spectrometry experiment

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Rand, Kasper Dyrberg

    2016-01-01

    are produced after precursor ion selection and thus do not add complexity to the LC-MS analysis. The key to obtaining optimal spatial resolution in a hydrogen exchange mass spectrometry (HX-MS) experiment is the fragmentation efficiency. This chapter discusses common fragmentation techniques like collision....../D scrambling, thus making them suitable for HX applications. By combining the classic bottom-up HX-MS workflow with gas-phase fragmentation by ETD, detailed information on protein HX can be obtained....

  1. Peach Water Relations, Gas Exchange, Growth and Shoot Mortality under Water Deficit in Semi-Arid Weather Conditions

    OpenAIRE

    Rahmati, Mitra; Davarynejad, Gholam Hossein; G?nard, Michel; Bannayan, Mohammad; Azizi, Majid; Vercambre, Gilles

    2015-01-01

    In this study the sensitivity of peach tree (Prunus persica L.) to three water stress levels from mid-pit hardening until harvest was assessed. Seasonal patterns of shoot and fruit growth, gas exchange (leaf photosynthesis, stomatal conductance and transpiration) as well as carbon (C) storage/mobilization were evaluated in relation to plant water status. A simple C balance model was also developed to investigate sink-source relationship in relation to plant water status at the tree level. The...

  2. Drought limitations to leaf-level gas exchange: results from a model linking stomatal optimization and cohesion-tension theory

    Science.gov (United States)

    Kimberly A. Novick; Chelcy F. Miniat; James M. Vose

    2016-01-01

    We merge concepts from stomatal optimization theory and cohesion–tension theory to examine the dynamics of three mechanisms that are potentially limiting to leaf-level gas exchange in trees during drought: (1) a ‘demand limitation’ driven by an assumption of optimal stomatal functioning; (2) ‘hydraulic limitation’ of water movement from the roots to the leaves...

  3. International exchange of radiological information in emergency conditions

    International Nuclear Information System (INIS)

    De Cort, M.; De Vries, G.; Breitenbach, L.; Fraser, G.; Vade, S.

    1998-01-01

    Description of the current system, experience gained, and expected future developments is given for the ECURIE system and, in particular, the EURDEP European-wide radiological information exchange system. It is concluded that the existing situation continues to be inhomogeneous. Although EURDEP foresees a common format for data exchange, which has been successfully implemented in 9 European countries, and regular exercises for data have been performed for a few years, important efforts will still have to be made to come to a more homogeneous and consistent European system for radiological information exchange. (P.A.)

  4. Improvements in or relating to heat exchangers

    International Nuclear Information System (INIS)

    Graham, L.W.; Sturge, D.W.J.; Ridealgh, F.

    1978-01-01

    A heat exchanger is described that is suitable for use with high temperature gas cooled reactors in which the heat is used as process heat. The construction which is of necessity of large size, is of much lighter weight than current constructions and is better able to withstand the high operating temperature (up to about 1000 0 C). Carbon fibre reinforced carbon materials are employed as constructional materials. A method of fabrication is described. The heat exchanger comprises a tube or bundle of tubes associated with a header plate, and the tube can be of helical form. The carbon materials may be formed by carbonisation of a thermosetting plastic such as a phenolic resin. The exchanger is rendered substantially impermeable to gas by an infiltration treatment of the carbon material using a cracked hydrocarbon gas. (U.K.)

  5. Improvements in or relating to heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Graham, L W; Sturge, D W.J.; Ridealgh, F

    1978-04-05

    A heat exchanger is described that is suitable for use with high temperature gas cooled reactors in which the heat is used as process heat. The construction which is of necessity of large size, is of much lighter weight than current constructions and is better able to withstand the high operating temperature (up to about 1000/sup 0/C). Carbon fibre reinforced carbon materials are employed as constructional materials. A method of fabrication is described. The heat exchanger comprises a tube or bundle of tubes associated with a header plate, and the tube can be of helical form. The carbon materials may be formed by carbonisation of a thermosetting plastic such as a phenolic resin. The exchanger is rendered substantially impermeable to gas by an infiltration treatment of the carbon material using a cracked hydrocarbon gas.

  6. Estimation of bias with the single-zone assumption in measurement of residential air exchange using the perfluorocarbon tracer gas method.

    Science.gov (United States)

    Van Ryswyk, K; Wallace, L; Fugler, D; MacNeill, M; Héroux, M È; Gibson, M D; Guernsey, J R; Kindzierski, W; Wheeler, A J

    2015-12-01

    Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single-zone AER (AER(1z)). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two-zone AER estimate (AER(2z)). In total, 287 daily pairs of AER(2z) and AER(1z) estimates were made from 35 homes across three cities. In 87% of the cases, AER(2z) was higher than AER(1z). Overall, the AER(1z) estimates underestimated AER(2z) by approximately 16% (IQR: 5-32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well-mixed air zone very likely results in an under prediction of the AER. The results of this study suggest that the long-standing assumption that a home represents a single well-mixed air zone may result in a substantial negative bias in air exchange estimates. Indoor air quality professionals should take this finding into consideration when developing study designs or making decisions related to the recommendation and installation of residential ventilation systems. © 2014 Her Majesty the Queen in Right of Canada. Indoor Air published by John Wiley & Sons Ltd Reproduced with the permission of the Minister of Health Canada.

  7. Co-flow anode/cathode supply heat exchanger for a solid-oxide fuel cell assembly

    Science.gov (United States)

    Haltiner, Jr., Karl J.; Kelly, Sean M.

    2005-11-22

    In a solid-oxide fuel cell assembly, a co-flow heat exchanger is provided in the flow paths of the reformate gas and the cathode air ahead of the fuel cell stack, the reformate gas being on one side of the exchanger and the cathode air being on the other. The reformate gas is at a substantially higher temperature than is desired in the stack, and the cathode gas is substantially cooler than desired. In the co-flow heat exchanger, the temperatures of the reformate and cathode streams converge to nearly the same temperature at the outlet of the exchanger. Preferably, the heat exchanger is formed within an integrated component manifold (ICM) for a solid-oxide fuel cell assembly.

  8. Effects of ozone on growth, yield and leaf gas exchange rates of two Bangladeshi cultivars of wheat (Triticum aestivum L.)

    International Nuclear Information System (INIS)

    Akhtar, Nahid; Yamaguchi, Masahiro; Inada, Hidetoshi; Hoshino, Daiki; Kondo, Taisuke; Izuta, Takeshi

    2010-01-01

    To clarify the effects of O 3 on crop plants cultivated in Bangladesh, two Bangladeshi wheat cultivars (Sufi and Bijoy) were grown in plastic boxes filled with Andisol and exposed daily to charcoal-filtered air or O 3 at 60 and 100 nl l -1 (10:00-17:00) from 13 March to 4 June 2008. The whole-plant dry mass and grain yield per plant of the two cultivars at the final harvest were significantly reduced by the exposure to O 3 . Although there was no significant effect of O 3 on stomatal diffusive conductance to H 2 O of flag leaf, net photosynthetic rate of the leaf was significantly reduced by the exposure to O 3. The sensitivity of growth, yield, yield components and leaf gas exchange rates to O 3 was not significantly different between the two cultivars. The results obtained in the present study suggest that ambient levels of O 3 may detrimentally affect wheat production in Bangladesh. - The exposure to ambient levels of ozone decreases growth, yield and leaf gas exchange rates of two Bangladeshi cultivars of wheat.

  9. [Vitrectomy and gas-fluid exchange for the treatment of serous macular detachment due to optic disc pit: long-term evaluation].

    Science.gov (United States)

    Moreira Neto, Carlos Augusto; Moreira Junior, Carlos Augusto

    2013-01-01

    To evaluate 5 patients with serous macular detachment due to optic disc pit that were submitted to pars plana vitrectomy and were followed for at least 7 years. Patients were submitted to pars plana vitrectomy, posterior hyaloid removal, autologous serum injection and gas-fluid exchange, without laser photocoagulation, and were evaluated pre and post-operatively with visual acuity and Amsler grid testing, retinography, and recently, with autofluorescence imaging and high resolution OCT. All 5 eyes improved visual acuity significantly following the surgical procedure maintaining good vision throughout the follow-up period. Mean pre-operative visual acuity was 20/400 and final visual acuity was 20/27 with a mean follow-up time of 13.6 years. No recurrences of serous detachments were observed. OCT examinations demonstrated an attached retina up to the margin of the pit. Serous macular detachments due to optic disc pits were adequately treated with pars plana vitrectomy and gas fluid exchange, without the need for laser photocoagulation, maintaining excellent visual results for a long period of time.

  10. Air Circulation and Heat Exchange Under Reduced Pressures

    Science.gov (United States)

    Rygalov, V.; Wheeler, R.; Dixon, M.; Fowler, P.; Hillhouse, L.

    2010-01-01

    Heat exchange rates decrease non-linearly with reductions in atmospheric pressure. This decrease creates risk of thermal stress (elevated leaf temperatures) for plants under reduced pressures. Forced convection (fans) significantly increases heat exchange rate under almost all pressures except below 10 kPa. Plant cultivation techniques under reduced pressures will require forced convection. The cooling curve technique is a reliable means of assessing the influence of environmental variables like pressure and gravity on gas exchange of plant. These results represent the extremes of gas exchange conditions for simple systems under variable pressures. In reality, dense plant canopies will exhibit responses in between these extremes. More research is needed to understand the dependence of forced convection on atmospheric pressure. The overall thermal balance model should include latent and radiative exchange components.

  11. Surfactant control of air-sea gas exchange from North Sea coastal waters and the Atlantic Meridional Transect

    Science.gov (United States)

    Pereira, R.

    2016-02-01

    Suppression of gas transfer velocity (kw) by surfactants are well established, both in laboratory wind flumes and purposeful oceanic releases. However, the effects on kw of time and space varying concentrations of natural surfactant are inadequately studied. We have developed an automated gas exchange tank for simultaneous high precision measurement of kw in unmodified seawater samples. Here we present data from two studies along a coastal North Sea transect during 2012-2013 and the Atlantic Meridional Transect (AMT) 24 from September to November 2014. Measurements of surfactant activity (SA), CDOM absorbance and chlorophyll-a have enabled us to characterize the effects of variable amounts of natural surfactant on kw. North Sea coastal waters range in k660 (kw normalized to the value for CO2 in freshwater at 20oC) was 6.8-24.5 cm hr-1 (n=20), with the ranges of SA, total CDOM absorbance (200-450 nm) and chlorophyll-a measured in the surface microlayer (SML) of our seawater samples were 0.08-0.38 mg l-1 T-X-100, 0.13-4.7 and 0.09-1.54 µg l-1, respectively. The AMT k660 ranged from 7.0-23.9 cm hr-1 (n=22), with SA measured in the SML and subsurface water (SSW) of our seawater samples ranging from 0.15-1.08 mg l-1 T-X-100 and 0.07-0.43 mg l-1 T-X-100, respectively. Importantly, we found 12-45% (North Sea) and 1-43% (AMT) k660 suppression relative to Milli-Q water that relate to seasonal and spatial differences in SA. The North Sea demonstrated notable seasonal influences on k660 suppression that were related to CDOM absorbance and chlorophyll-a. The degree of k660 suppression was highest in summer consistent with k660 control by natural surfactant. The degree of k660 suppression decreased with distance offshore in the North Sea and displayed a strong relationship with SA (r2 = 0.51-0.64, p = 0.02, n = 20). The AMT demonstrated notable differences in k660 suppression between hemispheres and across the Longhurst Provinces but the overall relationship between k660

  12. A Numerical Study on Using Air Cooler Heat Exchanger for Low Grade Energy Recovery from Exhaust Flue Gas in Natural Gas Pressure Reduction Stations

    Directory of Open Access Journals (Sweden)

    Mansoor Naderi

    2018-01-01

    Full Text Available Heat EXchangers (HEX that are used in City Gate Station (CGS systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the cooling fluid. Then, the effects of sizes and numbers of fins and tube rows on recovered heat rate were investigated under various pump speeds. As the first step in solving the problem, SST k–ω and RNG k–ε suitable viscous models were chosen for these kinds of problems. Secondly, a new HEX is designed at a fixed coolant speed, pipe and fin thickness, and shell dimension because of operational constraints. Finally, the best HEX with the minimum pressure drop (minimum fin number is numerically analyzed, and the new HEX specifications were extracted.

  13. Drought effect on growth, gas exchange and yield, in two strains of local barley Ardhaoui, under water deficit conditions in southern Tunisia.

    Science.gov (United States)

    Thameur, Afwa; Lachiheb, Belgacem; Ferchichi, Ali

    2012-12-30

    Two local barley strains cv. Ardhaoui originated from Tlalit and Switir, sourthern Tunisia were grown in pots in a glasshouse assay, under well-watered conditions for a month. Plants were then either subjected to water deficit (treatment) or continually well-watered (control). Control pots were irrigated several times each week to maintain soil moisture near field capacity (FC), while stress pots experienced soil drying by withholding irrigation until they reached 50% of FC. Variation in relative water content, leaf area, leaf appearance rate and leaf gas exchange (i.e. net CO(2) assimilation rate (A), transpiration (E), and stomatal conductance (gs)) in response to water deficit was investigated. High leaf relative water content (RWC) was maintained in Tlalit by stomatal closure and a reduction of leaf area. Reduction in leaf area was due to decline in leaf gas exchange during water deficit. Tlalit was found to be drought tolerant and able to maintain higher leaf RWC under drought conditions. Water deficit treatment reduced stomatal conductance by 43% at anthesis. High net CO(2) assimilation rate under water deficit was associated with high RWC (r = 0.998; P gas exchange parameters were found, which can give some indications on the degree of drought tolerance. Thus, the ability of the low leaf area plants to maintain higher RWC could explain the differences in drought tolerance in studied barley strains. Results showed that Tlalit showed to be more efficient and more productive than Switir. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Characterizing the drivers of seedling leaf gas exchange responses to warming and altered precipitation: indirect and direct effects.

    Science.gov (United States)

    Smith, Nicholas G; Pold, Grace; Goranson, Carol; Dukes, Jeffrey S

    2016-01-01

    Anthropogenic forces are projected to lead to warmer temperatures and altered precipitation patterns globally. The impact of these climatic changes on the uptake of carbon by the land surface will, in part, determine the rate and magnitude of these changes. However, there is a great deal of uncertainty in how terrestrial ecosystems will respond to climate in the future. Here, we used a fully factorial warming (four levels) by precipitation (three levels) manipulation experiment in an old-field ecosystem in the northeastern USA to examine the impact of climatic changes on leaf carbon exchange in five species of deciduous tree seedlings. We found that photosynthesis generally increased in response to increasing precipitation and decreased in response to warming. Respiration was less sensitive to the treatments. The net result was greater leaf carbon uptake in wetter and cooler conditions across all species. Structural equation modelling revealed the primary pathway through which climate impacted leaf carbon exchange. Net photosynthesis increased with increasing stomatal conductance and photosynthetic enzyme capacity (V cmax ), and decreased with increasing respiration of leaves. Soil moisture and leaf temperature at the time of measurement most heavily influenced these primary drivers of net photosynthesis. Leaf respiration increased with increasing soil moisture, leaf temperature, and photosynthetic supply of substrates. Counter to the soil moisture response, respiration decreased with increasing precipitation amount, indicating that the response to short- (i.e. soil moisture) versus long-term (i.e. precipitation amount) water stress differed, possibly as a result of changes in the relative amounts of growth and maintenance demand for respiration over time. These data (>500 paired measurements of light and dark leaf gas exchange), now publicly available, detail the pathways by which climate can impact leaf gas exchange and could be useful for testing assumptions in

  15. Probing peptide fragment ion structures by combining sustained off-resonance collision-induced dissociation and gas-phase H/D exchange (SORI-HDX) in Fourier transform ion-cyclotron resonance (FT-ICR) instruments.

    Science.gov (United States)

    Somogyi, Arpád

    2008-12-01

    The usefulness of gas-phase H/D exchange is demonstrated to probe heterogeneous fragment and parent ion populations. Singly and multiply protonated peptides/proteins were fragmented by using sustained off-resonance irradiation collision-induced dissociation (SORI-CID). The fragments and the surviving precursor ions then all undergo H/D exchange in the gas-phase with either D(2)O or CD(3)OD under the same experimental conditions. Usually, 10 to 60 s of reaction time is adequate to monitor characteristic differences in the H/D exchange kinetic rates. These differences are then correlated to isomeric ion structures. The SORI-HDX method can be used to rapidly test fragment ion structures and provides useful insights into peptide fragmentation mechanisms.

  16. Process for the production of hydrogen/deuterium-containing gas

    International Nuclear Information System (INIS)

    Nitschke, E.; Desai, A.; Ilgner, H.

    1978-01-01

    A process for the production of hydrogen/deuterium-containing gas is described in which the enriched condensate obtained from the production of a hydrogen/deuterium-containing gas mixture is collected and subjected to a direct exchange of isotopes with the feedsteam admitted to the process. Such condensate can be brought into direct exchange of isotopes with the gas water vapor mixture within the process, viz. ahead of the CO conversion section. The exchange of isotopes may be performed according to the counter-current principle. If it is intended to maintain in the hydrogen/deuterium-containing gas a certain definite content of water vapor whose phase condition is superior to the condition achieved when using normal cooling water, this gas, at least 0.6 kg/m 3 of gas, is subjected to an exchange of isotopes with the water fed additionally into the process

  17. Incremental exercise test performance with and without a respiratory ...

    African Journals Online (AJOL)

    Incremental exercise test performance with and without a respiratory gas collection system. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... Industrial- type mask wear is thought to impair exercise performance through increased respiratory dead space, flow ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  18. Heterogeneous Catalysis: Deuterium Exchange Reactions of Hydrogen and Methane

    Science.gov (United States)

    Mirich, Anne; Miller, Trisha Hoette; Klotz, Elsbeth; Mattson, Bruce

    2015-01-01

    Two gas phase deuterium/hydrogen exchange reactions are described utilizing a simple inexpensive glass catalyst tube containing 0.5% Pd on alumina through which gas mixtures can be passed and products collected for analysis. The first of these exchange reactions involves H[subscript 2] + D[subscript 2], which proceeds at temperatures as low as 77…

  19. Catalytic process for tritium exchange reaction

    International Nuclear Information System (INIS)

    Hansoo Lee; Kang, H.S.; Paek, S.W.; Hongsuk Chung; Yang Geun Chung; Sook Kyung Lee

    2001-01-01

    The catalytic activities for a hydrogen isotope exchange were measured through the reaction of a vapor and gas mixture. The catalytic activity showed to be comparable with the published data. Since the gas velocity is relatively low, the deactivation was not found clearly during the 5-hour experiment. Hydrogen isotope transfer experiments were also conducted through the liquid phase catalytic exchange reaction column that consisted of a catalytic bed and a hydrophilic bed. The efficiencies of both the catalytic and hydrophilic beds were higher than 0.9, implying that the column performance was excellent. (author)

  20. Pulmonary gas exchange impairment following tourniquet deflation: a prospective, single-blind clinical trial.

    Science.gov (United States)

    Lin, Lina; Wang, Liangrong; Bai, Yu; Zheng, Liupu; Zhao, Xiyue; Xiong, Xiangqing; Jin, Lida; Ji, Wei; Wang, Wantie

    2010-06-09

    The tourniquet has been considered as a recognized cause of limb ischemia/reperfusion injury in orthopedic surgery resulting in a transient neutrophil, monocyte activation, and enhanced neutrophil transendothelial migration with potential remote tissue injury. This study investigated the effect of unilateral tourniquet application within a safe time limit on pulmonary function and the roles of lipid peroxidation and systemic inflammatory response. Thirty patients undergoing unilateral lower extremity surgery with or without tourniquet were equally divided into a control group with no tourniquet (Group C) and a tourniquet (Group T). Arterial partial pressure of oxygen (P(a)O(2)), arterial-alveolar oxygen tension ratio (a/A ratio), alveolar-arterial oxygen difference (A-aDO(2)) and respiratory index, plasma malondialdehyde, serum interleukin (IL) -6 and IL-8 levels were measured immediately before and 1 hour after tourniquet inflation/operation beginning, 0.5, 2, 6, and 24 hours after tourniquet deflation/operation ending. The results represented no significant changes in Group C with regard to either blood gas variables or levels of circulating mediators, while blood gas variable changes of greater A-aDO(2) and respiratory index and lower PaO2 and a/A ratio were shown at 6 hours following tourniquet deflation. The levels of malondialdehyde, IL-6, and IL-8 were increased over baseline values from 2 to 24 hours following tourniquet deflation in Group T. We concluded that tourniquet application within a safe time limit may cause pulmonary gas exchange impairment several hours after tourniquet deflation, where lipid peroxidation and systemic inflammatory response may be involved. Copyright 2010, SLACK Incorporated.

  1. Protein structural dynamics at the gas/water interface examined by hydrogen exchange mass spectrometry.

    Science.gov (United States)

    Xiao, Yiming; Konermann, Lars

    2015-08-01

    Gas/water interfaces (such as air bubbles or foam) are detrimental to the stability of proteins, often causing aggregation. This represents a potential problem for industrial processes, for example, the production and handling of protein drugs. Proteins possess surfactant-like properties, resulting in a high affinity for gas/water interfaces. The tendency of previously buried nonpolar residues to maximize contact with the gas phase can cause significant structural distortion. Most earlier studies in this area employed spectroscopic tools that could only provide limited information. Here we use hydrogen/deuterium exchange (HDX) mass spectrometry (MS) for probing the conformational dynamics of the model protein myoglobin (Mb) in the presence of N(2) bubbles. HDX/MS relies on the principle that unfolded and/or highly dynamic regions undergo faster deuteration than tightly folded segments. In bubble-free solution Mb displays EX2 behavior, reflecting the occurrence of short-lived excursions to partially unfolded conformers. A dramatically different behavior is seen in the presence of N(2) bubbles; EX2 dynamics still take place, but in addition the protein shows EX1 behavior. The latter results from interconversion of the native state with conformers that are globally unfolded and long-lived. These unfolded species likely correspond to Mb that is adsorbed to the surface of gas bubbles. N(2) sparging also induces aggregation. To explain the observed behavior we propose a simple model, that is, "semi-unfolded" ↔ "native" ↔ "globally unfolded" → "aggregated". This model quantitatively reproduces the experimentally observed kinetics. To the best of our knowledge, the current study marks the first exploration of surface denaturation phenomena by HDX/MS. © 2015 The Protein Society.

  2. Effect of simultaneously induced environmental stimuli on electrical signalling and gas exchange in maize plants.

    Science.gov (United States)

    Vuralhan-Eckert, Jasmin; Lautner, Silke; Fromm, Jörg

    2018-04-01

    Electrical signalling in response to environmental stimuli is a well-known phenomenon in higher plants. For example, in maize, different stimuli, such as wounding or re-irrigation after drought, incite characteristic electrical signals which have quite particular effects on gas exchange. What is less well understood is how plants (specifically maize) respond when two different environmental stimuli are applied simultaneously. To explore this, a three-stage experiment was designed. In the first stage, drought conditions were simulated by decreasing the soil water content to 30-40 % of field capacity. In these conditions, and in contrast to well-watered plants, the maize exhibited only 60-70% of the original level of stomatal conductance and 50-60 % of the original photosynthesis rate. In the second stage of the experiment the plants were re-irrigated and heat stimulated separately. Re-irrigation led to specific electrical signals followed by a gradual increase of gas exchange. In contrast, after heat stimulation of a leaf an electrical signal was evoked that reduced the net CO 2 -uptake rate as well as stomatal conductance. In the third stage, to elucidate how plants process simultaneous re-irrigation and heat stimulation, the drought-stressed maize plants were re-watered and heat-stimulated at the same time. Results showed a two phase response. In the first phase there was a rapid decrease in both the CO 2 uptake rate and the stomatal conductance, while in the second phase each of these parameters increased gradually. Thus, the results strongly support the view that the responses from both stimuli were combined, indicating that maize plants can process simultaneously applied stimuli. Copyright © 2018 Elsevier GmbH. All rights reserved.

  3. Radiation-use efficiency and gas exchange responses to water and nutrient availability in irrigated and fertilized stands of sweetgum and sycamore

    Science.gov (United States)

    Christopher B. Allen; Rodney E. Will; Robert C. McGravey; David R. Coyle; Mark D. Coleman

    2005-01-01

    We investigated how water and nutrient availability affect radiation-use effeciency (e) and assessed leaf gas exchange as a possible mechanism for shifts in e. We measured aboveground net primary production (ANPP) and annual photosynthetically active radiation (PAR) capture to calculate e as well as leaf-level physiological variables (light-saturated net photosynthesis...

  4. Low-cost photonic sensors for carbon dioxide exchange rate measurement

    Science.gov (United States)

    Bieda, Marcin S.; Sobotka, Piotr; Lesiak, Piotr; Woliński, Tomasz R.

    2017-10-01

    Carbon dioxide (CO2) measurement has an important role in atmosphere monitoring. Usually, two types of measurements are carried out. The first one is based on gas concentration measurement while the second involves gas exchange rate measurement between earth surface and atmosphere [1]. There are several methods which allow gas concentration measurement. However, most of them require expensive instrumentation or large devices (i.e. gas chambers). In order to precisely measure either CO2 concentration or CO2 exchange rate, preferably a sensors network should be used. These sensors must have small dimensions, low power consumption, and they should be cost-effective. Therefore, this creates a great demand for a robust low-power and low-cost CO2 sensor [2,3]. As a solution, we propose a photonic sensor that can measure CO2 concentration and also can be used to measure gas exchange by using the Eddy covariance method [1].

  5. A leaf gas exchange model that accounts for intra-canopy variability by considering leaf nitrogen content and local acclimation to radiation in grapevine (Vitis vinifera L.).

    Science.gov (United States)

    Prieto, Jorge A; Louarn, Gaëtan; Perez Peña, Jorge; Ojeda, Hernán; Simonneau, Thierry; Lebon, Eric

    2012-07-01

    Understanding the distribution of gas exchange within a plant is a prerequisite for scaling up from leaves to canopies. We evaluated whether leaf traits were reliable predictors of the effects of leaf ageing and leaf irradiance on leaf photosynthetic capacity (V(cmax) , J(max) ) in field-grown vines (Vitis vinifera L). Simultaneously, we measured gas exchange, leaf mass per area (LMA) and nitrogen content (N(m) ) of leaves at different positions within the canopy and at different phenological stages. Daily mean leaf irradiance cumulated over 10 d (PPFD(10) ) was obtained by 3D modelling of the canopy structure. N(m) decreased over the season in parallel to leaf ageing while LMA was mainly affected by leaf position. PPFD(10) explained 66, 28 and 73% of the variation of LMA, N(m) and nitrogen content per area (N(a) ), respectively. Nitrogen content per unit area (N(a) = LMA × N(m) ) was the best predictor of the intra-canopy variability of leaf photosynthetic capacity. Finally, we developed a classical photosynthesis-stomatal conductance submodel and by introducing N(a) as an input, the model accurately simulated the daily pattern of gas exchange for leaves at different positions in the canopy and at different phenological stages during the season. © 2012 Blackwell Publishing Ltd.

  6. Capture of elemental and organic iodine from dilute gas streams by silver-exchanged mordenite

    Energy Technology Data Exchange (ETDEWEB)

    Bruffey, S.H.; Jubin, R.T.; Jordan, J.A. [Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831 (United States)

    2016-07-01

    The treatment of off-gas streams arising from reprocessing of used nuclear fuel (UNF) is an area of active study by the U.S. Department of Energy. Such off-gas streams contain volatile fission products, including long-lived {sup 129}I. Although {sup 129}I is released into the off-gas at multiple points within the chemical reprocessing flowsheet, previous research has focused on removal from the dissolver off-gas stream (DOG). The DOG is expected to contain up to 98% of iodine in UNF at ppm levels within the stream. Other off-gas streams will also contain iodine but at substantially lower concentrations. Recent work has shown that compliance with U.S. regulations will likely require capture of iodine from these dilute streams in addition to capture from DOG. In particular, the vessel off-gas (VOG) stream is expected to contain 1-3% of the total iodine inventory at ppb concentrations. A review of literature also indicates that the speciation of iodine in the VOG stream will differ from that of the DOG, with the DOG containing primarily I{sub 2} and the VOG containing a mixture of I{sub 2} and organic iodine species. Silver-exchanged mordenite (AgZ) has been identified for use in the removal of iodine from off-gas streams. It is an effective capture material for I{sub 2} at the concentrations expected in the DOG, but little is known about its performance in gas streams that may contain both I{sub 2} and organic iodides at very dilute concentrations. The experiments to be described were designed to separately characterize the adsorption of I{sub 2} and methyl iodide on AgZ through extended duration testing. Simulated vessel off-gases containing low levels of either I{sub 2} or methyl iodide were contacted with AgZ sorbent beds for up to four months. Through the use of sorbent beds in series and varied sampling times, key parameters such as adsorption rate, decontamination factor, and performance over time could be determined for the capture of each species by AgZ. This

  7. 17 CFR 200.43 - Disposition of business by exercise of authority delegated to individual Commissioner.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false Disposition of business by... Exchanges SECURITIES AND EXCHANGE COMMISSION ORGANIZATION; CONDUCT AND ETHICS; AND INFORMATION AND REQUESTS Disposition of Commission Business § 200.43 Disposition of business by exercise of authority delegated to...

  8. Research of thermal stability of ion exchangers

    International Nuclear Information System (INIS)

    Stuchlik, S.; Srnkova, J.

    1983-01-01

    Prior to the fixation of radioactive ion exchangers into bitumen these exchangers have to be dried. The resulting gaseous products may generate explosive mixtures. An analysis was made of the thermal stability of two types of ion exchangers, the cation exchanger KU-2-8 cS and the anion exchanger AV-17-8 cS which are used in the V-1 nuclear power plant at Jaslovske Bohunice. The thermal stability of the anion exchangers was monitored using gas chromatography at temperatures of 100, 120, 140, 160 and 180 degC and by measuring weight loss by kiln-drying at temperatures of 120, 140, 160 and 180 degC. The ion exchanger was heated for 6 hours and samples were taken continuously at one hour intervals. The thermal stability of the cation exchanger was monitored by measuring the weight loss. Gas chromatography showed the release of trimethylamine from the anion exchanger in direct dependence on temperature. The measurement of weight losses, however, only showed higher losses of released products which are explained by the release of other thermally unstable products. The analysis of the thermal stability of the cation exchanger showed the release of SO 2 and the weight loss (following correction for water content) was found only after the fourth hour of decomposition. The experiment showed that the drying of anion exchanger AV-17-8 cS may cause the formation of explosive mixtures. (J.P.)

  9. Rosatom Corporation at the All-Russian civil defence training exercise

    International Nuclear Information System (INIS)

    Glukhikh, E.N.; Glazunov, A.V.; Tyurin, R.L.

    2012-01-01

    The 80th anniversary of civil defence in Russia was marked by the All-Russian civil defence exercise attended by representatives of federal executive authorities, regional and local executive authorities. During the exercise performance of the following activities was verified: introduction of increased preparedness mode for local air-defence emergency-response forces, activities of emergency-response and fire safety commissions, information collection and exchange during implementation of top-priority civil defence measures, etc. The paper describes the activities carried out during the exercise [ru

  10. Intra- and interspecific differences of 10 barley and 10 tomato cultivars in response to short-time UV-B radiation: A study analysing thermoluminescence, fluorescence, gas-exchange and biochemical parameters

    International Nuclear Information System (INIS)

    Gilbert, Matthias; Poers, Yvonne; Grover, Kirsten; Weingart, Ilka; Skotnica, Jiri; Grimm, Bernhard; Seidlitz, Harald K.; Langebartels, Christian; Wilhelm, Christian

    2009-01-01

    The impact of UV-B radiation on 10 genotypically different barley and tomato cultivars was tested in a predictive study to screen for potentially UV-tolerant accessions and to analyze underlying mechanisms for UV-B sensitivity. Plant response was analyzed by measuring thermoluminescence, fluorescence, gas exchange and antioxidant status. Generally, barley cultivars proved to be much more sensitive against UV-B radiation than tomato cultivars. Statistical cluster analysis could resolve two barley groups with distinct differences in reaction patterns. The UV-B sensitive group showed a stronger loss in PSII photochemistry and a lower gas-exchange performance and regulation after UV-B radiation compared to the more tolerant group. The results indicate that photosynthetic light and dark reactions have to play optimally in concert to render plants more tolerant against UV-B radiation. Hence, measuring thermoluminescence/fluorescence and gas exchange in parallel will have much higher potential in identifying tolerant cultivars and will help to understand the underlying mechanisms. - Mechanisms of UV-B tolerance and sensitivity in crop plants.

  11. Scientific Verification Test of Orbitec Deployable Vegetable Production System for Salad Crop Growth on ISS- Gas Exchange System design and function

    Science.gov (United States)

    Eldemire, Ashleigh

    2007-01-01

    The ability to produce and maintain salad crops during long term missions would be a great benefit to NASA; the renewable food supply would save cargo space, weight and money. The ambient conditions of previous ground controlled crop plant experiments do not reflect the microgravity and high CO2 concentrations present during orbit. It has been established that microgravity does not considerably alter plant growth. (Monje, Stutte, Chapman, 2005). To support plants in a space-craft environment efficient and effective lighting and containment units are necessary. Three lighting systems were previously evaluated for radish growth in ambient air; fluorescent lamps in an Orbitec Biomass Production System Educational (BPSE), a combination of red, blue, and green LED's in a Deployable Vegetable Production System (Veggie), and a combination of red and blue LED's in a Veggie. When mass measurements compared the entire possible growing area vs. power consumed by the respective units, the Veggies clearly exceeded the BPSE indicating that the LED units were a more resource efficient means of growing radishes under ambient conditions in comparison with fluorescent lighting. To evaluate the most productive light treatment system for a long term space mission a more closely simulated ISS environment is necessary. To induce a CO2 dense atmosphere inside the Veggie's and BPSE a gas exchange system has been developed to maintain a range of 1000-1200 ppm CO2 during a 21-day light treatment experiment. This report details the design and function of the gas exchange system. The rehabilitation, trouble shooting, maintenance and testing of the gas exchange system have been my major assignments. I have also contributed to the planting, daily measurements and harvesting of the radish crops 21-day light treatment verification test.

  12. Heat exchanger for coal gasification process

    Science.gov (United States)

    Blasiole, George A.

    1984-06-19

    This invention provides a heat exchanger, particularly useful for systems requiring cooling of hot particulate solids, such as the separated fines from the product gas of a carbonaceous material gasification system. The invention allows effective cooling of a hot particulate in a particle stream (made up of hot particulate and a gas), using gravity as the motive source of the hot particulate. In a preferred form, the invention substitutes a tube structure for the single wall tube of a heat exchanger. The tube structure comprises a tube with a core disposed within, forming a cavity between the tube and the core, and vanes in the cavity which form a flow path through which the hot particulate falls. The outside of the tube is in contact with the cooling fluid of the heat exchanger.

  13. The Driving Forces of Guest Substitution in Gas Hydrates—A Laser Raman Study on CH4-CO2 Exchange in the Presence of Impurities

    Directory of Open Access Journals (Sweden)

    Bettina Beeskow-Strauch

    2012-02-01

    Full Text Available The recovery of CH4 gas from natural hydrate formations by injection of industrially emitted CO2 is considered to be a promising solution to simultaneously access an unconventional fossil fuel reserve and counteract atmospheric CO2 increase. CO2 obtained from industrial processes may contain traces of impurities such as SO2 or NOx and natural gas hydrates may contain higher hydrocarbons such as C2H6 and C3H8. These additions have an influence on the properties of the resulting hydrate phase and the conversion process of CH4-rich hydrates to CO2-rich hydrates. Here we show results of a microscopic and laser Raman in situ study investigating the effects of SO2-polluted CO2 and mixed CH4-C2H6 hydrate on the exchange process. Our study shows that the key driving force of the exchange processes is the establishment of the chemical equilibrium between hydrate phase and the surrounding phases. The exchange rate is also influenced by the guest-to-cavity ratio as well as the thermodynamic stability in terms of p-T conditions of the original and resulting hydrate phase. The most effective molecule exchange is related to structural changes (sI-sII which indicates that hydrate decomposition and reformation processes are the occurring processes.

  14. Effect of stratified inequality of blood flow on gas exchange in liquid-filled lungs.

    Science.gov (United States)

    West, J. B.; Maloney, J. E.; Castle, B. L.

    1972-01-01

    This investigation set out to answer two questions: (1) are the distal alveoli in the terminal lung units less well perfused than the proximal alveoli, i.e., is there stratification of blood flow; and (2) if so, does this enhance gas exchange in the presence of stratified inequality of ventilation. Excised dog lungs were ventilated with saline and perfused with blood. Following single inspirations of xenon 133 in saline and various periods of breath holding, the expired xenon concentration against volume was measured and it confirmed marked stratified inequality of ventilation under these conditions. By measuring the rate of depletion of xenon from alveoli during a period of blood flow, we showed that the alveoli which emptied at the end of expiration had 16% less blood flow than those exhaling earlier. However, by measuring the xenon concentration in pulmonary venous blood, we found that about 10% less tracer was transferred from the alveoli into the blood when the inspired xenon was stratified within the respiratory zone. Thus while stratification of blood flow was confirmed, it was shown to impair rather than enhance the efficiency of gas transfer.

  15. Modelling of the change in national exchange rate model depending on the economic parameters of a natural gas cogeneration system: Turkey case

    International Nuclear Information System (INIS)

    Inan, Aslan; Izgi, Ercan; Ay, Selim

    2009-01-01

    In this paper, to what extent a cogeneration system's fixed and variable costs and profits are affected from the exchange rate model implemented in the country is examined. An autoproductor system, as known, uses a part of its electrical energy production for its own requirements while selling the remaining energy to the regional energy corporation. As a function of the load factor and the fuel cost, the production cost and energy sale income of the system are influenced much by the exchange rate model of the country. A cost analysis of a natural gas cogeneration (autoproductor) system has been performed for the numerical application, based on the monetary program supported by the IMF commenced in January 2000. In order to investigate the effect of the change in exchange rate model (introducing the floating exchange rate model) on the fuel cost, both the characteristics of the IMF program and some various forecasting methods have been utilized

  16. Heat pipe heat exchangers in heat recovery systems

    Energy Technology Data Exchange (ETDEWEB)

    Stulc, P; Vasiliev, L L; Kiseljev, V G; Matvejev, Ju N

    1985-01-01

    The results of combined research and development activities of the National Research Institute for Machine Design, Prague, C.S.S.R. and the Institute for Heat and Mass Transfer, Minsk, U.S.S.R. concerning intensification heat pipes used in heat pipe heat exchangers are presented. This sort of research has been occasioned by increased interest in heat power economy trying to utilise waste heat produced by various technological processes. The developed heat pipes are deployed in construction of air-air, gas-air or gas-gas heat recovery exchangers in the field of air-engineering and air-conditioning. (author).

  17. Atypical blood glucose response to continuous and interval exercise in a person with type 1 diabetes: a case report.

    Science.gov (United States)

    Moser, Othmar; Tschakert, Gerhard; Mueller, Alexander; Groeschl, Werner; Pieber, Thomas R; Koehler, Gerd; Eckstein, Max L; Bracken, Richard M; Hofmann, Peter

    2017-06-30

    Therapy must be adapted for people with type 1 diabetes to avoid exercise-induced hypoglycemia caused by increased exercise-related glucose uptake into muscles. Therefore, to avoid hypoglycemia, the preexercise short-acting insulin dose must be reduced for safety reasons. We report a case of a man with long-lasting type 1 diabetes in whom no blood glucose decrease during different types of exercise with varying exercise intensities and modes was found, despite physiological hormone responses. A Caucasian man diagnosed with type 1 diabetes for 24 years performed three different continuous high-intensity interval cycle ergometer exercises as part of a clinical trial (ClinicalTrials.gov identifier NCT02075567). Intensities for both modes of exercises were set at 5% below and 5% above the first lactate turn point and 5% below the second lactate turn point. Short-acting insulin doses were reduced by 25%, 50%, and 75%, respectively. Measurements taken included blood glucose, blood lactate, gas exchange, heart rate, adrenaline, noradrenaline, cortisol, glucagon, and insulin-like growth factor-1. Unexpectedly, no significant blood glucose decreases were observed during all exercise sessions (start versus end, 12.97 ± 2.12 versus 12.61 ± 2.66 mmol L -1 , p = 0.259). All hormones showed the expected response, dependent on the different intensities and modes of exercises. People with type 1 diabetes typically experience a decrease in blood glucose levels, particularly during low- and moderate-intensity exercises. In our patient, we clearly found no decline in blood glucose, despite a normal hormone response and no history of any insulin insensitivity. This report indicates that there might be patients for whom the recommended preexercise therapy adaptation to avoid exercise-induced hypoglycemia needs to be questioned because this could increase the risk of severe hyperglycemia and ketosis.

  18. Information on the REAL84 exercise

    International Nuclear Information System (INIS)

    Zijp, W.L.; Cullen, D.E.

    1986-01-01

    This document gives information on the interlaboratory exercise REAL84. This exercise has as aim the improvement of the assessment of accuracies in radiation damage predictions by using good quality input data and proper calculation methods. In the exercise integral damage parameters (such as displacements per atom, or produced gas atoms) and spectrum characteristics are calculated for neutron spectra which are adjusted to fit experimental reaction rates obtained with activation spectrometry. The main difference with the preceding exercise REAL80 is that now improved information can be applied in the input data sets of the exercise. The improvement concerns mainly the availability of uncertainty information for the neutron spectrum and cross-section data. All parties interested are encouraged to participate in the exercise and to request from the IAEA the magnetic tape R84, which contains all input information. In order to meet the time schedule (see appendix) fast action is required. (author)

  19. Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.

    Science.gov (United States)

    Prella, Maura; Feihl, François; Domenighetti, Guido

    2002-10-01

    The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration. Prospective, observational study. A multidisciplinary ICU in a nonuniversity, acute-care hospital. Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years). Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones. PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

  20. Air-water oxygen exchange in a large whitewater river

    Science.gov (United States)

    Hall, Robert O.; Kennedy, Theodore A.; Rosi-Marshall, Emma J.

    2012-01-01

    Air-water gas exchange governs fluxes of gas into and out of aquatic ecosystems. Knowing this flux is necessary to calculate gas budgets (i.e., O2) to estimate whole-ecosystem metabolism and basin-scale carbon budgets. Empirical data on rates of gas exchange for streams, estuaries, and oceans are readily available. However, there are few data from large rivers and no data from whitewater rapids. We measured gas transfer velocity in the Colorado River, Grand Canyon, as decline in O2 saturation deficit, 7 times in a 28-km segment spanning 7 rapids. The O2 saturation deficit exists because of hypolimnetic discharge from Glen Canyon Dam, located 25 km upriver from Lees Ferry. Gas transfer velocity (k600) increased with slope of the immediate reach. k600 was -1 in flat reaches, while k600 for the steepest rapid ranged 3600-7700 cm h-1, an extremely high value of k600. Using the rate of gas exchange per unit length of water surface elevation (Kdrop, m-1), segment-integrated k600 varied between 74 and 101 cm h-1. Using Kdrop we scaled k600 to the remainder of the Colorado River in Grand Canyon. At the scale corresponding to the segment length where 80% of the O2 exchanged with the atmosphere (mean length = 26.1 km), k600 varied 4.5-fold between 56 and 272 cm h-1 with a mean of 113 cm h-1. Gas transfer velocity for the Colorado River was higher than those from other aquatic ecosystems because of large rapids. Our approach of scaling k600 based on Kdrop allows comparing gas transfer velocity across rivers with spatially heterogeneous morphology.

  1. Project, construction and assembling of a compact heat exchanger for natural gas generator; Nacionalizacao de um recuperador de calor destinado ao reaproveitamento energetico dos gases de combustao de uma microturbina alimentada com gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Correia, Raphael Chaves; Dutra, Jose Carlos Charamba; Santos, Thiago Victor de Oliveira; Oliveira, Guilherme Lacerda Batista de [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2008-07-01

    The objective of this work is to present the construction of a heat exchanger developed for reuse of hot gases from a natural gas microturbine installed at the Laboratory of Micro-CHP at Federal University of Pernambuco. As in Brazil there was no manufacturer of similar equipment that could be used with this microturbine and imported equipment is very expensive, it, has proposed a project to CNPq for development of a national prototype, capable of replacing imports. The work talks about the design, construction, assembly, instrumentation and operation. The paper presents data taken from heat exchanger in operation. We recorded the temperature of fluids and held thermal exchange, which allowed the calculation of its effectiveness. The results show that the heat exchanger reached a satisfactory performance with maximum effectiveness of 0.8, condition for the full load of microturbine, and that represents a maximum heat recovered around 50 kW. (author)

  2. Parallel changes in the onset of blood lactate accumulation (OBLA) and threshold of psychomotor performance deterioration during incremental exercise after training in athletes.

    Science.gov (United States)

    Chmura, Jan; Nazar, Krystyna

    2010-03-01

    During aerobic exercise with increasing intensities choice reaction time (CRT) progressively shortens up to 60-80% of maximal workload, and then it rapidly increases. The aim of this study was to determine whether workload associated with the shortest CRT operationally called "the psychomotor fatigue threshold" is related to the metabolic response to exercise. Thirteen male soccer players (aged 23.3 + or - 1.0 yrs) participated in this study. Before and after 6 weeks of training in the pre-competition period they underwent treadmill test at 0 grade with running speed increasing every 3 min by 2 km/h starting from 6 km/h until exhaustion. At each stage of exercise CRT, heart rate, respiratory gas exchange and blood lactate [LA] were measured and the workload corresponding to [LA] of 4 mmol/l (OBLA) was recorded. After training, CRT was significantly shortened at rest (from m + or - SEM = 345 + or - 12 to 317 + or - 12 ms) and during exercise (from 304 + or - 10 to 285 + or - 11 ms at the psychomotor fatigue threshold and from 359 + or - 13 to 331 + or - 13 ms, pchanges in OBLA occurring during training and those in psychomotor fatigue threshold (r = 0.88). It is concluded that endurance training not only increases exercise tolerance due to its influence on metabolism but also facilitates psychomotor performance during heavy exercise. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Water-gas exchange of organochlorine pesticides at Lake Chaohu, a large Chinese lake.

    Science.gov (United States)

    Ouyang, Hui-Ling; He, Wei; Qin, Ning; Kong, Xiang-Zhen; Liu, Wen-Xiu; He, Qi-Shuang; Yang, Chen; Jiang, Yu-Jiao; Wang, Qing-Mei; Yang, Bin; Xu, Fu-Liu

    2013-04-01

    Organochlorine pesticides (OCPs), a potential threat to ecosystems and human health, are still widely residual in the environment. The residual levels of OCPs in the water and gas phase were monitored in Lake Chaohu, a large Chinese lake, from March 2010 to February 2011. Nineteen types of OCPs were detected in the water with a total concentration of 7.27 ± 3.32 ng/l. Aldrin, DDTs and HCHs were the major OCPs in the water, accounting for 38.3%, 28.9% and 23.6% of the total, respectively. The highest mean concentration (12.32 ng/l) in the water was found in September, while the lowest (1.74 ng/l) was found in November. Twenty types of gaseous OCPs were detected in the atmosphere with a total concentration of 542.0 ± 636.5 pg/m(3). Endosulfan, DDTs and chlordane were the major gaseous OCPs in the atmosphere, accounting for 48.9%, 22.5% and 14.4% of the total, respectively. The mean concentration of gaseous OCPs was significantly higher in summer than in winter. o,p'-DDE was the main metabolite of DDT in both the water and gas phase. Of the HCHs, 52.3% existed as β-HCH in the water, while α-HCH (37.9%) and γ-HCH (30.9%) were dominant isomers in the gas phase. The average fluxes were -21.11, -3.30, -152.41, -35.50 and -1314.15 ng/(m(2) day) for α-HCH, γ-HCH, HCB, DDT and DDE, respectively. The water-gas exchanges of the five types of OCPs indicate that water was the main potential source of gaseous OCPs in the atmosphere. A sensitivity analysis indicated that the water-gas flux of α-HCH, γ-HCH and DDT is more vulnerable than that of HCB and DDE to the variation of the parameters. The possible source of the HCHs in the water was from the historical usage of lindane; however, that in the air was mainly from the recent usage of lindane. The technical DDT and dicofol might be the source of DDTs in the water and air.

  4. Gas magnetometer

    Science.gov (United States)

    Walker, Thad Gilbert; Lancor, Brian Robert; Wyllie, Robert

    2016-05-03

    Measurement of a precessional rate of a gas, such as an alkali gas, in a magnetic field is made by promoting a non-uniform precession of the gas in which substantially no net magnetic field affects the gas during a majority of the precession cycle. This allows sensitive gases that would be subject to spin-exchange collision de-phasing to be effectively used for extremely sensitive measurements in the presence of an environmental magnetic field such as the Earth's magnetic field.

  5. Dissociation between lactate and proton exchange in muscle during intense exercise in man

    DEFF Research Database (Denmark)

    Bangsbo, Jens; Juel, Carsten; Hellsten, Ylva

    1997-01-01

    1. Transport of lactate, H+ and fluid across muscle sarcolemma was studied in contracting muscles under varying blood acid-base conditions. 2. Subjects performed two-legged submaximal knee-extensor exercise for 29-35 min consisting of warming up for 5 min followed by 10 min of leg exercise (L1...

  6. Tritium stripping by a catalytic exchange stripper

    International Nuclear Information System (INIS)

    Heung, L.K.; Gibson, G.W.; Ortman, M.S.

    1991-01-01

    A catalytic exchange process for stripping elemental tritium from gas streams has been demonstrated. The process uses a catalyzed isotopic exchange reaction between tritium in the gas phase and protium or deuterium in the solid phase on alumina. The reaction is catalyzed by platinum deposited on the alumina. The process has been tested with both tritium and deuterium. Decontamination factors (ration of inlet and outlet tritium concentrations) as high as 1000 have been achieved, depending on inlet concentration. The test results and some demonstrated applications are presented

  7. Recoverying device for sodium vapor in inert gas

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Tamotsu; Nagashima, Ikuo

    1992-11-06

    A multi-pipe type heat exchanger for cooling an inert gas and a mist trap connected to the inert gas exit of the heat exchanger are disposed. A mist filter having bottomed pipes made of an inert gas-permeable sintered metal is disposed in the mist trap, and an inert gas discharge port is disposed at the upper side wall. With such a constitution, a high temperature inert gas containing sodium vapors can be cooled efficiently by the multi-pipe type heat exchanger capable of easy temperature control, thereby converting sodium vapors into mists, and the inert gas containing sodium mists can be flown into the mist trap. Sodium mists are collected by the mist filter and sodium mists flown down are discharged from the discharge port. With such procedures, a great amount of the inert gas containing sodium vapors can be processed continuously. (T.M.).

  8. Leaf age affects the responses of foliar injury and gas exchange to tropospheric ozone in Prunus serotina seedlings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jianwei, E-mail: jianweizhang@fs.fed.u [Environmental Resources Research Institute, Pennsylvania State University, University Park, PA 16802 (United States); School of Forest Resources, Pennsylvania State University, University Park, PA 16802 (United States); Schaub, Marcus; Ferdinand, Jonathan A. [Environmental Resources Research Institute, Pennsylvania State University, University Park, PA 16802 (United States); Skelly, John M. [Department of Plant Pathology, Pennsylvania State University, University Park, PA 16802 (United States); Steiner, Kim C. [School of Forest Resources, Pennsylvania State University, University Park, PA 16802 (United States); Savage, James E. [Department of Plant Pathology, Pennsylvania State University, University Park, PA 16802 (United States)

    2010-08-15

    We investigated the effect of leaf age on the response of net photosynthesis (A), stomatal conductance (g{sub wv}), foliar injury, and leaf nitrogen concentration (N{sub L}) to tropospheric ozone (O{sub 3}) on Prunus serotina seedlings grown in open-plots (AA) and open-top chambers, supplied with either carbon-filtered or non-filtered air. We found significant variation in A, g{sub wv}, foliar injury, and N{sub L} (P < 0.05) among O{sub 3} treatments. Seedlings in AA showed the highest A and g{sub wv} due to relatively low vapor pressure deficit (VPD). Older leaves showed significantly lower A, g{sub wv}, N{sub L}, and higher foliar injury (P < 0.001) than younger leaves. Leaf age affected the response of A, g{sub wv}, and foliar injury to O{sub 3}. Both VPD and N{sub L} had a strong influence on leaf gas exchange. Foliar O{sub 3}-induced injury appeared when cumulative O{sub 3} uptake reached 8-12 mmol m{sup -2}, depending on soil water availability. The mechanistic assessment of O{sub 3}-induced injury is a valuable approach for a biologically relevant O{sub 3} risk assessment for forest trees. - Ozone effects on symptom development and leaf gas exchange interacted with leaf age and N-content on black cherry seedlings.

  9. Effect of body position changes on pulmonary gas exchange in Eisenmenger's syndrome.

    Science.gov (United States)

    Sandoval, J; Alvarado, P; Martínez-Guerra, M L; Gómez, A; Palomar, A; Meza, S; Santos, E; Rosas, M

    1999-04-01

    Preliminary studies on sleep of patients with congenital heart disease and Eisenmenger's syndrome (ES) at our institution demonstrated nocturnal worsening arterial unsaturation, which appeared to be a body position-related phenomenon. To investigate the potential effect of body position on gas exchange in ES, we carried out a prospective study of 28 patients (mean age, 34.8 +/- 11.7 yr) with established ES due to congenital heart disease. In every patient, arterial blood gases were performed during both sitting and supine positions under three different conditions: room air, while breathing 100% oxygen, and after breathing oxygen at a flow rate of 3 L/min through nasal prongs. Alveolar oxygen pressure (PaO2) for the calculation of alveolar-arterial oxygen tension differences (AaPO2) was derived from the alveolar gas equation using PaCO2 and assuming R = 1. We used paired t test, repeated-measures two-way ANOVA with Bonferroni's test, and regression analysis. From sitting to supine position on room air, there was a significant decrease in PaO2 (from 52.5 +/- 7.5 to 47.5 +/- 5.5 mm Hg; p position. A ventilation-perfusion (V/Q) distribution abnormality and/or a diffusion limitation phenomenon rather than an increase in true shunt may be the mechanisms responsible for this finding. The response to nasal O 2 we observed warrants a trial with long-term nocturnal oxygen therapy in these patients.

  10. Timing Foreign Exchange Markets

    Directory of Open Access Journals (Sweden)

    Samuel W. Malone

    2016-03-01

    Full Text Available To improve short-horizon exchange rate forecasts, we employ foreign exchange market risk factors as fundamentals, and Bayesian treed Gaussian process (BTGP models to handle non-linear, time-varying relationships between these fundamentals and exchange rates. Forecasts from the BTGP model conditional on the carry and dollar factors dominate random walk forecasts on accuracy and economic criteria in the Meese-Rogoff setting. Superior market timing ability for large moves, more than directional accuracy, drives the BTGP’s success. We explain how, through a model averaging Monte Carlo scheme, the BTGP is able to simultaneously exploit smoothness and rough breaks in between-variable dynamics. Either feature in isolation is unable to consistently outperform benchmarks throughout the full span of time in our forecasting exercises. Trading strategies based on ex ante BTGP forecasts deliver the highest out-of-sample risk-adjusted returns for the median currency, as well as for both predictable, traded risk factors.

  11. Cardiopulmonary Exercise Testing in Patients with Idiopathic Scoliosis.

    Science.gov (United States)

    Shen, Jianxiong; Lin, Youxi; Luo, Jinmei; Xiao, Yi

    2016-10-05

    reserve (p = 0.014). Overall exercise tolerance was not correlated with the magnitude of the thoracic curve and kyphosis. Some parameters of ventilatory function and pulmonary gas exchange worsened as thoracic curvature increased or kyphosis decreased. Exercise capacity was better in patients who engaged in regular aerobic exercise, and physical activity is recommended for patients with idiopathic scoliosis. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  12. Development of heat transfer calculation program for finned-tune heat exchanger of multi-burner boiler

    International Nuclear Information System (INIS)

    Jang, Sae Byul; Kim, Jong Jin; Ahn, Joon

    2009-01-01

    We develop a heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a Heat Recovery Steam Generator (HRSG). This heat recovery system has 8 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 1 MPa and tested steam pressure is 0.7 MPa. In order to test these heat exchanger modules, we make a 0.5 t/h flue tube boiler (LNG, 40 Nm 3 /h). We tested the heat exchanger module with changing the position of each heat exchanger module. We measured the inlet and outlet temperature of each heat exchanger module and calculated the heat exchange rate. Based on test results, we develop a heat transfer calculation program to predict flue gas. Calculation results show that temperature and temperature difference between measured and calculated flue gas exit temperature is less than 20 .deg. C when flue gas inlet temperature is 620 .deg. C.

  13. Cerebral water and ion balance remains stable when humans are exposed to acute hypoxic exercise

    DEFF Research Database (Denmark)

    Avnstorp, Magnus B; Rasmussen, Peter; Brassard, Patrice

    2015-01-01

    both circumstances. No cerebral net exchange of Na(+) or K(+) was evident. Likewise, no significant net-exchange of water over the brain was demonstrated and the arterial and jugular venous hemoglobin concentrations were similar. CONCLUSION: Challenging exercise in hypoxia for 30 min affected muscle......Avnstorp, Magnus B., Peter Rasmussen, Patrice Brassard, Thomas Seifert, Morten Overgaard, Peter Krustrup, Niels H. Secher, and Nikolai B. Nordsborg. Cerebral water and ion balance remains stable when humans are exposed to acute hypoxic exercise. High Alt Med Biol 16:000-000, 2015.-Background...... intense exercise is carried out in hypoxia and monitored the influence of muscle metabolism for changes in arterial variables. METHODS: On two separate days, in random order, 30 min cycling exercise was performed in either hypoxia (10% O2) or normoxia at an intensity that was exhaustive in the hypoxic...

  14. Combined effects of mild-to-moderate obesity and asthma on physiological and sensory responses to exercise.

    Science.gov (United States)

    Cortés-Télles, Arturo; Torre-Bouscoulet, Luis; Silva-Cerón, Monica; Mejía-Alfaro, Roberto; Syed, Nafeez; Zavorsky, Gerald S; Guenette, Jordan A

    2015-11-01

    Despite the close link between asthma and obesity, there are no studies that have evaluated the sensory and physiological responses to exercise in obese asthmatics. We recently demonstrated that normal weight asthmatics with well controlled disease have preserved cardiorespiratory and sensory responses to exercise relative to non-asthmatic controls. However, these similarities may not hold true in patients with combined obesity and asthma. Accordingly, we sought to determine if combined asthma and obesity was associated with deleterious effects on cardiorespiratory fitness, exercise performance, dyspnoea, and physiological responses to exercise. Fourteen well-controlled obese asthmatics and fourteen age-matched normal weight asthmatics performed routine spirometry and underwent an incremental cardiopulmonary cycle test to assess the ventilatory, pulmonary gas exchange, cardiovascular, and sensory responses to exercise. Groups were well matched for age, height, spirometry, and asthma control. Obese asthmatics had a significantly greater body mass index (33 ± 3 vs. 23 ± 1 kg/m(2), p Obese asthmatics had a significantly lower maximal oxygen uptake (VO(2)) (82 ± 14 vs. 92 ± 10 %predicted) and work rate (75 ± 8 vs. 89 ± 13 %predicted) relative to normal weight asthmatics (p obese asthmatics vs. normal weight asthmatics (54 ± 15 vs. 66 ± 16 %predicted, p exercise with no evidence of a ventilatory limitation in either group. Cardiovascular responses were normal in both groups. Dyspnoea responses were similar but the obese asthmatics experienced greater leg fatigue ratings at submaximal work rates. In conclusion, obese individuals with well controlled asthma have reduced cardiorespiratory fitness and greater leg fatigue ratings relative to normal weight asthmatics. The relatively reduced cardiorespiratory fitness and exercise performance in obese compared to normal weight asthmatics is most likely driven by their more sedentary lifestyle and resultant

  15. Leaf water potential, gas exchange and chlorophyll a fluorescence in acariquara seedlings (Minquartia guianensis Aubl.) under water stress and recovery

    OpenAIRE

    Liberato, Maria Astrid Rocha; Gonçalves, José Francisco de Carvalho; Chevreuil, Larissa Ramos; Nina Junior, Adamir da Rocha; Fernandes, Andreia Varmes; Santos Junior, Ulysses Moreira dos

    2006-01-01

    The physiological performance of acariquara (Minquartia guianensis) seedlings submitted to water deficit and the recovery of physiological parameters during rehydration were investigated in a greenhouse experiment. The analyzed parameters were: leaf water potential, gas exchange and chlorophyll a fluorescence. After thirty-five days, non-irrigated plants exhibited a leaf water potential 70 % lower compared to control plants (irrigated daily) and the stomatal conductance reached values close t...

  16. Control systems for condensing flue-gas coolers related to natural-gas-fired heating plants

    International Nuclear Information System (INIS)

    Krighaar, M.; Paulsen, O.

    1992-01-01

    A theoretical study is made of the enthalpy-efficiency for a water-cooled heat exchanger added to a natural gas-fired boiler. Under varying conditions of both water flow and temperature and flue-gas flow and temperature, both in condensing and non-condensing mode, the efficiency seems to be constant. The result is very useful for comparison between two different working conditions. The efficiency is used to calculate the savings achieved for a district heating plant by using a heat exchanger. The energy economic calculations are also helpful for estimating the most appropriate size of heat exchanger. The annual savings are calculated by means of data regarding heat production, flue gas temperature and water return temperature. The savings achieved by using different connection principles such as bypass, reheating and controlled water temperature are also calculated. (author)

  17. In vivo effects of Aphanizomenon flos-aquae DC-1 aphantoxins on gas exchange and ion equilibrium in the zebrafish gill.

    Science.gov (United States)

    Zhang, Delu; Liu, Siyi; Zhang, Jing; Zhang, Jian Kong; Hu, Chunxiang; Liu, Yongding

    2016-08-01

    Aphantoxins, neurotoxins or paralytic shellfish poisons (PSPs) generated by Aphanizomenon flos-aquae, are a threat to environmental safety and human health in eutrophic waters worldwide. The molecular mechanisms of neurotoxin function have been studied; however, the effects of these neurotoxins on oxidative stress, ion transport, gas exchange, and branchial ultrastructure in fish gills are not fully understood. Aphantoxins extracted from A. flos-aquae DC-1 were detected by high-performance liquid chromatography. The major ingredients were gonyautoxins 1 and 5 and neosaxitoxin, which comprised 34.04%, 21.28%, and 12.77% of the total, respectively. Zebrafish (Danio rerio) were administered A. flos-aquae DC-1 aphantoxins at 5.3 or 7.61μg saxitoxin equivalents (eq)/kg (low and high doses, respectively) by intraperitoneal injection. The activities of Na(+)-K(+)-ATPase (NKA), carbonic anhydrase (CA), and lactate dehydrogenase (LDH), ultrastructural alterations in chloride and epithelial cells, and reactive oxygen species (ROS) and total antioxidative capacity (T-AOC) were investigated in the gills during the first 24h after exposure. Aphantoxins significantly increased the level of ROS and decreased the T-AOC in zebrafish gills from 3 to 12h post-exposure, suggesting an induction of oxidative stress and inhibition of antioxidant capacity. Reduced activities of NKA and CA demonstrated abnormal ion transport and gas exchange in the gills of aphantoxin-treated fish. Toxin administration also resulted in increased LDH activity and ultrastructural alterations in chloride and epithelial cells, suggesting a disruption of function and structure in zebrafish gills. The observed abnormalities in zebrafish gills occurred in a time- and dose-dependent manner. These findings demonstrate that aphantoxins or PSPs may inhibit ion transport and gas exchange, increase LDH activity, and result in ultrastructural damage to the gills through elevations in oxidative stress and reduced

  18. Greenhouse gas exchange of rewetted bog peat extraction sites and a Sphagnum cultivation site in northwest Germany

    Science.gov (United States)

    Beyer, C.; Höper, H.

    2015-04-01

    During the last decades an increasing area of drained peatlands has been rewetted. Especially in Germany, rewetting is the principal treatment on cutover sites when peat extraction is finished. The objectives are bog restoration and the reduction of greenhouse gas (GHG) emissions. The first sites were rewetted in the 1980s. Thus, there is a good opportunity to study long-term effects of rewetting on greenhouse gas exchange, which has not been done so far on temperate cutover peatlands. Moreover, Sphagnum cultivating may become a new way to use cutover peatlands and agriculturally used peatlands as it permits the economical use of bogs under wet conditions. The climate impact of such measures has not been studied yet. We conducted a field study on the exchange of carbon dioxide, methane and nitrous oxide at three rewetted sites with a gradient from dry to wet conditions and at a Sphagnum cultivation site in NW Germany over the course of more than 2 years. Gas fluxes were measured using transparent and opaque closed chambers. The ecosystem respiration (CO2) and the net ecosystem exchange (CO2) were modelled at a high temporal resolution. Measured and modelled values fit very well together. Annually cumulated gas flux rates, net ecosystem carbon balances (NECB) and global warming potential (GWP) balances were determined. The annual net ecosystem exchange (CO2) varied strongly at the rewetted sites (from -201.7 ± 126.8 to 29.7± 112.7g CO2-C m-2 a-1) due to differing weather conditions, water levels and vegetation. The Sphagnum cultivation site was a sink of CO2 (-118.8 ± 48.1 and -78.6 ± 39.8 g CO2-C m-2 a-1). The annual CH4 balances ranged between 16.2 ± 2.2 and 24.2 ± 5.0g CH4-C m-2 a-1 at two inundated sites, while one rewetted site with a comparatively low water level and the Sphagnum farming site show CH4 fluxes close to 0. The net N2O fluxes were low and not significantly different between the four sites. The annual NECB was between -185.5 ± 126.9 and 49

  19. Effect of gamma radiation on wheat plant growth due to impact on gas exchange characteristics and mineral nutrient uptake and utilization

    International Nuclear Information System (INIS)

    Bhupinder Singh; Sumedha Ahuja; Singhal, R.K.; Venu Babu, P.

    2013-01-01

    The experiment was conducted to determine the effect of gamma radiation on plant growth and development, flag leaf gas exchange characteristics such as net photosynthetic rate (P N ), stomatal conductance (g s ), and transpiration rate (E) and activity of key carbon and nitrogen assimilating enzymes like Rubisco, starch synthase (SS) and nitrate reductase (NR) in field grown wheat. Grains of cultivar PBW-343 were exposed to a 60 Co (Cobalt-60) gamma source at a dose range from 0 to 500 Gy (Gray). Gas exchange characteristics of flag leaf were measured using Infrared Gas Analyzer (IRGA), while mineral nutrients were analyzed spectrophotometrically. Our results show that an irradiation treatment, in general, caused an improvement in plant growth and yield characteristics such as shoot and root mass, root length and surface area, leaf area and chlorophyll SPAD index, tiller number and grain yield. However, irradiation exceeding 5 Gy reduced the magnitude of radiation advantage for most of the investigated physiological and biochemical traits. No germination was recorded at 500 Gy irradiation dose. A dose-dependant increase in shoot Fe in radiated plants up to 25 Gy reflected its higher plant root to shoot translocation which may yield micronutrient rich grains. At higher dose of 100 Gy, there was a drastic reduction in flag leaf membrane stability index (MSI), photosynthesis, Rubisco, NR, and nutrients like K, P, Mg, Fe, and Zn. Starch synthase enzyme activity was unaffected by gamma irradiation indicating that the negative effect of high dose (100 Gy) on the grain yield were caused by the adverse effect of radiation on the gas exchange attributes particularly photosynthesis, carbon, and nitrogen assimilation efficiency and the plant uptake of mineral nutrients. The study concludes that gamma radiation at a low dose (25 Gy or lower) stimulates, while a high dose (100 Gy and above) inhibits plant growth and development of wheat. The adverse effect at 100 Gy and beyond

  20. Blind prediction exercise on modeling of PHWR fuel at extended burnup

    International Nuclear Information System (INIS)

    Sah, D.N.; Viswanathan, U.K.; Viswanadham, C.S.; Unnikrishnan, K.; Rath, B.N.

    2008-01-01

    A blind prediction exercise was organised on Indian Pressurised Heavy Water Reactor (PHWR) fuel to investigate the predictive capability of existing codes for their application at extended burnup and to identify areas of improvement. The blind problem for this exercise was based on a PHWR fuel bundle irradiated in Kakrapar Atomic Power Station-I (KAPS-I) up to about 15 000 MWd/tU and subjected to detailed post-irradiation examination (PIE) in the hot cells facility at BARC. Eleven computer codes from seven countries participated in this exercise. The participants provided blind predictions of fuel temperature, fission gas release, internal gas pressure and other performance parameters for the fuel pins. The predictions were compared with the experimental PIE data which included fuel temperature derived from fuel restructuring, fission gas release measured by fuel pin puncturing, internal gas pressure in pin, cladding oxidation and fuel microstructural data. The details of the blind problem and an analysis of the results of blind predictions by the codes vis-a-vis measured data are provided in this paper

  1. Carbon source/sink function of a subtropical, eutrophic lake determined from an overall mass balance and a gas exchange and carbon burial balance

    International Nuclear Information System (INIS)

    Yang Hong; Xing Yangping; Xie Ping; Ni Leyi; Rong Kewen

    2008-01-01

    Although studies on carbon burial in lake sediments have shown that lakes are disproportionately important carbon sinks, many studies on gaseous carbon exchange across the water-air interface have demonstrated that lakes are supersaturated with CO 2 and CH 4 causing a net release of CO 2 and CH 4 to the atmosphere. In order to more accurately estimate the net carbon source/sink function of lake ecosystems, a more comprehensive carbon budget is needed, especially for gaseous carbon exchange across the water-air interface. Using two methods, overall mass balance and gas exchange and carbon burial balance, we assessed the carbon source/sink function of Lake Donghu, a subtropical, eutrophic lake, from April 2003 to March 2004. With the overall mass balance calculations, total carbon input was 14 905 t, total carbon output was 4950 t, and net carbon budget was +9955 t, suggesting that Lake Donghu was a great carbon sink. For the gas exchange and carbon burial balance, gaseous carbon (CO 2 and CH 4 ) emission across the water-air interface totaled 752 t while carbon burial in the lake sediment was 9477 t. The ratio of carbon emission into the atmosphere to carbon burial into the sediment was only 0.08. This low ratio indicates that Lake Donghu is a great carbon sink. Results showed good agreement between the two methods with both showing Lake Donghu to be a great carbon sink. This results from the high primary production of Lake Donghu, substantive allochthonous carbon inputs and intensive anthropogenic activity. Gaseous carbon emission accounted for about 15% of the total carbon output, indicating that the total output would be underestimated without including gaseous carbon exchange. - Due to high primary production, substantive allochthonous carbon inputs and intensive anthropogenic acitivity, subtropical, eutrophic Lake Donghu is a great carbon sink

  2. Estimation of air-water gas exchange coefficient in a shallow lagoon based on 222Rn mass balance.

    Science.gov (United States)

    Cockenpot, S; Claude, C; Radakovitch, O

    2015-05-01

    The radon-222 mass balance is now commonly used to quantify water fluxes due to Submarine Groundwater Discharge (SGD) in coastal areas. One of the main loss terms of this mass balance, the radon evasion to the atmosphere, is based on empirical equations. This term is generally estimated using one among the many empirical equations describing the gas transfer velocity as a function of wind speed that have been proposed in the literature. These equations were, however, mainly obtained from areas of deep water and may be less appropriate for shallow areas. Here, we calculate the radon mass balance for a windy shallow coastal lagoon (mean depth of 6m and surface area of 1.55*10(8) m(2)) and use these data to estimate the radon loss to the atmosphere and the corresponding gas transfer velocity. We present new equations, adapted to our shallow water body, to express the gas transfer velocity as a function of wind speed at 10 m height (wind range from 2 to 12.5 m/s). When compared with those from the literature, these equations fit particularly well with the one of Kremer et al. (2003). Finally, we emphasize that some gas transfer exchange may always occur, even for conditions without wind. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Exercising is like flogging a dead horse

    International Nuclear Information System (INIS)

    Molhoek, W.

    2003-01-01

    Full text: To explore the international aspects of nuclear accidents, the OECD Nuclear Energy Agency initiated and established an international nuclear emergency 'exercise culture', starting with the INEX 1 table-top exercise, the first international nuclear emergency exercise in 1993, followed by the series of real time command-post exercises INEX 2 and INEX 2000 (five exercises between 1996 - 2001). Deficiencies in the area of communication and information exchange were the most significant findings of the INEX 2 series and corrective actions represent a major step forward in nuclear emergency management. The development of a new communication and information exchange strategy, which is currently implemented by various countries as well as by the international community, has strengthened our preparedness and response to nuclear emergencies. In addition, one of these exercises explored for the first time third party liability procedures and compensation after a nuclear accident. Regarding the role of international organizations, the INEX 2 series contributed to a better clarification regarding the roles of relevant international organizations, their obligations and responsibilities, and how their response in the case of a nuclear emergency are co-ordinated and harmonized. On the national level, many countries participating in INEX 1 and INEX 2 exercises used the experiences and lessons learned to modify and improve national procedures for nuclear emergency preparedness and management. Countries also used the outcome of the exercises to update bilateral agreements and arrangements. As an important follow-up of the lessons learned, an OECD/NEA-working group established the report: monitoring and data management strategies for nuclear emergencies. To test the implementation of the features of the outcome of the report, e.g. the effectiveness of developed data matrix and the effectiveness of proposed communication strategies employing new technologies, the INEX-2000

  4. Air-sea gas exchange of HCHs and PCBs and enantiomers of α-HCH in the Kattegat Sea region

    International Nuclear Information System (INIS)

    Sundqvist, Kristina L.; Wingfors, Haakan; Brorstoem-Lunden, Eva; Wiberg, Karin

    2004-01-01

    Concentrations and air-water gas exchange of polychlorinated biphenyls (PCBs) and hexachlorocyclohexanes (HCHs) were determined in nine paired air and water samples. The samples were collected monthly in the Kattegat Sea between December 1998 and November 1999. Average fugacity and flux values indicated that PCBs were oversaturated in the water, while HCHs were net deposited. Variations were large over the year, especially during spring and summer. Air parcel back trajectories suggested that air concentrations over the Kattegat Sea are largely dependent of air mass origin. Seasonal trends were detected for airborne HCHs and for PCBs in water. The air and water enantiomeric compositions of α-HCH indicated that a larger portion of α-HCH in air originated from the underlying water during summer than during winter. - Air-water exchange of PCBs and HCHs is studied in the Kattegat Sea and shows to vary seasonally

  5. Numerical evaluation of various gas and coolant channel designs for high performance liquid-cooled proton exchange membrane fuel cell stacks

    International Nuclear Information System (INIS)

    Sasmito, Agus P.; Kurnia, Jundika C.; Mujumdar, Arun S.

    2012-01-01

    A careful design of gas and coolant channel is essential to ensure high performance and durability of proton exchange membrane (PEM) fuel cell stack. The channel design should allow for good thermal, water and gas management whilst keeping low pressure drop. This study evaluates numerically the performance of various gas and coolant channel designs simultaneously, e.g. parallel, serpentine, oblique-fins, coiled, parallel-serpentine and a novel hybrid parallel-serpentine-oblique-fins designs. The stack performance and local distributions of key parameters are investigated with regards to the thermal, water and gas management. The results indicate that the novel hybrid channel design yields the best performance as it constitutes to a lower pumping power and good thermal, water and gas management as compared to conventional channels. Advantages and limitation of the designs are discussed in the light of present numerical results. Finally, potential application and further improvement of the design are highlighted. -- Highlights: ► We evaluate various gas and coolant channel designs in liquid-cooled PEM fuel cell stack. ► The model considers coupled electrochemistry, channel design and cooling effect simultaneously. ► We propose a novel hybrid channel design. ► The novel hybrid channel design yields the best thermal, water and gas management which is beneficial for long term durability. ► The novel hybrid channel design exhibits the best performance.

  6. High temperature corrosion of advanced ceramic materials for hot gas filters and heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Crossland, C.E.; Shelleman, D.L.; Spear, K.E. [Pennsylvania State Univ., University Park, PA (United States)] [and others

    1996-08-01

    A vertical flow-through furnace has been built to study the effect of corrosion on the morphology and mechanical properties of ceramic hot gas filters. Sections of 3M Type 203 and DuPont Lanxide SiC-SiC filter tubes were sealed at one end and suspended in the furnace while being subjected to a simulated coal combustion environment at 870{degrees}C. X-ray diffraction and electron microscopy is used to identify phase and morphology changes due to corrosion while burst testing determines the loss of mechanical strength after exposure to the combustion gases. Additionally, a thermodynamic database of gaseous silicon compounds is currently being established so that calculations can be made to predict important products of the reaction of the environment with the ceramics. These thermodynamic calculations provide useful information concerning the regimes where the ceramic may be degraded by material vaporization. To verify the durability and predict lifetime performance of ceramic heat exchangers in coal combustion environments, long-term exposure testing of stressed (internally pressurized) tubes must be performed in actual coal combustion environments. The authors have designed a system that will internally pressurize 2 inch OD by 48 inch long ceramic heat exchanger tubes to a maximum pressure of 200 psi while exposing the outer surface of the tubes to coal combustion gas at the Combustion and Environmental Research Facility (CERF) at the Pittsburgh Energy and Technology Center. Water-cooled, internal o-ring pressure seals were designed to accommodate the existing 6 inch by 6 inch access panels of the CERF. Tubes will be exposed for up to a maximum of 500 hours at temperatures of 2500 and 2600{degrees}F with an internal pressure of 200 psi. If the tubes survive, their retained strength will be measured using the high temperature tube burst test facility at Penn State University. Fractographic analysis will be performed to identify the failure source(s) for the tubes.

  7. Air-water gas exchange of chlorinated pesticides in four lakes spanning a 1,205 meter elevation range in the Canadian Rocky Mountains.

    Science.gov (United States)

    Wilkinson, Andrew C; Kimpe, Lynda E; Blais, Jules M

    2005-01-01

    Concentrations of selected persistent organic pollutants (POPs) in air and water were measured from four lakes that transect the Canadian Rocky Mountains. These data were used in combination with wind velocity and temperature-adjusted Henry's law constants to estimate the direction and magnitude of chemical exchange across the air-water interface of these lakes. Bow Lake (1,975 m above sea level [masl]) was studied during the summers of 1998 through 2000; Donald (770 masl) was studied during the summer of 1999; Dixon Dam Lake (946 masl) and Kananaskis Lake (1,667 masl) were studied during the summer of 2000. Hexachlorobenzene (HCB) and dieldrin volatilized from Bow Lake in spring and summer of 1998 to 2000 at a rate of 0.92 +/-1.1 and 0.55+/-0.37 ng m(-2) d(-1), respectively. The alpha-endosulfan deposited to Bow Lake at a rate of 3.4+/-2.2 ng m(-2) d(-1). Direction of gas exchange for gamma-hexachlorocyclohexane (gamma-HCH) changed from net deposition in 1998 to net volatilization in 1999, partly because of a surge in y-HCH concentrations in the water at Bow Lake in 1999. Average gamma-HCH concentrations in air declined steadily over the three-year period, from 0.021 ng m(-3) in 1998, to 0.0023 ng m(-3) in 2000, and to volatilization in 1999 and 2000. Neither the concentrations of organochlorine compounds (OCs) in air and water, nor the direction and rate of air-water gas exchange correlate with temperature or elevation. In general, losses of pesticides by outflow were greater than the amount exchanged across the air-water interface in these lakes.

  8. Does prior acute exercise affect postexercise substrate oxidation in response to a high carbohydrate meal?

    Directory of Open Access Journals (Sweden)

    Hickey Matthew S

    2008-01-01

    Full Text Available Abstract Background Consumption of a mixed meal increases postprandial carbohydrate utilization and decreases fat oxidation. On the other hand, acute endurance exercise increases fat oxidation and decreases carbohydrate utilization during the post-exercise recovery period. It is possible that the resulting post-exercise increase in circulating nonesterified fatty acids could attenuate the ability of ingested carbohydrate to inhibit lipid oxidation. The purpose of this study was to determine whether prior exercise attenuates the usual meal-induced decline in lipid oxidation. Methods Six healthy, physically active young subjects (x age = 26.3 years, 4 males, 2 females completed three treatments in random order after a ~10 h fast: (a Exercise/Carbohydrate (Ex/CHO – subjects completed a bout of exercise at 70% VO2peak (targeted net energy cost of 400 kcals, followed by consumption of a carbohydrate-rich meal; (b Exercise/Placebo (Ex/Placebo – subjects completed an identical bout of exercise followed by consumption of a placebo; and (c No Exercise/Carbohydrate (NoEx/CHO – subjects sat quietly rather than exercising and then consumed the carbohydrate-rich meal. Blood samples were obtained before and during the postprandial period to determine plasma glucose, insulin, and non-esterified fatty acids (NEFA. Respiratory gas exchange measures were used to estimate rates of fat and carbohydrate oxidation. Results Plasma NEFA were approximately two-fold higher immediately following the two exercise conditions compared to the no-exercise condition, while meal consumption significantly increased insulin and glucose in both Ex/CHO and NoEx/CHO. NEFA concentrations fell rapidly during the 2-h postprandial period, but remained higher compared to the NoEx/CHO treatment. Carbohydrate oxidation increased rapidly and fat oxidation decreased in response to the meal, with no differences in the rates of carbohydrate and fat oxidation during recovery between the Ex

  9. Effects on hemodynamics and gas exchange of omega-3 fatty acid-enriched lipid emulsion in acute respiratory distress syndrome (ARDS: a prospective, randomized, double-blind, parallel group study

    Directory of Open Access Journals (Sweden)

    Sacanell Judit

    2008-10-01

    Full Text Available Abstract Introduction We investigated the effects on hemodynamics and gas exchange of a lipid emulsion enriched with omega-3 fatty acids in patients with ARDS. Methods The design was a prospective, randomized, double-blind, parallel group study in our Intensive Medicine Department of Vall d'Hebron University Hospital (Barcelona-Spain. We studied 16 consecutive patients with ARDS and intolerance to enteral nutrition (14 men and 2 women; mean age: 58 ± 13 years; APACHE II score: 17.8 ± 2.3; Lung Injury Score: 3.1 ± 0.5; baseline PaO2/FiO2 ratio: 149 ± 40. Patients were randomized into 2 groups: Group A (n = 8 received the study emulsion Lipoplus® 20%, B.Braun Medical (50% MCT, 40% LCT, 10% ω-3; Group B (n = 8 received the control emulsion Intralipid® Fresenius Kabi (100% LCT. Lipid emulsions were administered during 12 h at a dose of 0.12 g/kg/h. Measurements of the main hemodynamic and gas exchange parameters were made at baseline (immediately before administration of the lipid emulsions, every hour during the lipid infusion, at the end of administration, and six hours after the end of administration lipid infusion. Results No statistically significant changes were observed in the different hemodynamic values analyzed. Likewise, the gas exchange parameters did not show statistically significant differences during the study. No adverse effect attributable to the lipid emulsions was seen in the patients analyzed. Conclusion The lipid emulsion enriched with omega-3 fatty acids was safe and well tolerated in short-term administration to patients with ARDS. It did not cause any significant changes in hemodynamic and gas exchange parameters. Trial registration ISRCTN63673813

  10. Different Techniques of Respiratory Support Do Not Significantly Affect Gas Exchange during Cardiopulmonary Resuscitation in a Newborn Piglet Model.

    Science.gov (United States)

    Mendler, Marc R; Maurer, Miriam; Hassan, Mohammad A; Huang, Li; Waitz, Markus; Mayer, Benjamin; Hummler, Helmut D

    2015-01-01

    There are no evidence-based recommendations on the use of different techniques of respiratory support and chest compressions (CC) during neonatal cardiopulmonary resuscitation (CPR). We studied the short-term effects of different ventilatory support strategies along with CC representing clinical practice on gas exchange [arterial oxygen saturation (SaO2), arterial partial pressure of oxygen (PaO2) and arterial partial pressure of carbon dioxide (PaCO2)], hemodynamics and cerebral oxygenation. We hypothesized that in newborn piglets with cardiac arrest, use of a T-piece resuscitator (TPR) providing positive end-expiratory pressure (PEEP) improves gas exchange as measured by SaO2 during CPR as compared to using a self-inflating bag (SIB) without PEEP. Furthermore, we explored the effects of a mechanical ventilator without synchrony to CC. Thirty newborn piglets with asystole were randomized into three groups and resuscitated for 20 min [fraction of inspired oxygen (FiO2) = 0.21 for 10 min and 1.0 thereafter]. Group 1 received ventilation using a TPR [peak inspiratory pressure (PIP)/PEEP of 20/5 cm H2O, rate 30/min] with inflations interposed between CC (3:1 ratio). Group 2 received ventilation using a SIB (PIP of 20 cm H2O without PEEP, rate 30/min) with inflations interposed between CC (3:1 ratio). Group 3 received ventilation using a mechanical ventilator (PIP/PEEP of 20/5 cm H2O, rate 30/min). CC were applied with a rate of 120/min without synchrony to inflations. We found no significant differences in SaO2 between the three groups. However, there was a trend toward a higher SaO2 [TPR: 28.0% (22.3-40.0); SIB: 23.7% (13.4-52.3); ventilator: 44.1% (39.2-54.3); median (interquartile range)] and a lower PaCO2 [TPR: 95.6 mm Hg (82.1-113.6); SIB: 100.8 mm Hg (83.0-108.0); ventilator: 74.1 mm Hg (68.5-83.1); median (interquartile range)] in the mechanical ventilator group. We found no significant effect on gas exchange using different respiratory support strategies

  11. The hygric hypothesis does not hold water: abolition of discontinuous gas exchange cycles does not affect water loss in the ant Camponotus vicinus.

    Science.gov (United States)

    Lighton, John R B; Turner, Robbin J

    2008-02-01

    The discontinuous gas exchange cycle (DGC) of insects and other tracheate arthropods temporally decouples oxygen uptake and carbon dioxide emission and generates powerful concentration gradients for both gas species between the outside world and the tracheal system. Although the DGC is considered an adaptation to reduce respiratory water loss (RWL) - the "hygric hypothesis" - it is absent from many taxa, including xeric ones. The "chthonic hypothesis" states that the DGC originated as an adaptation to gas exchange in hypoxic and hypercapnic, i.e. underground, environments. If that is the case then the DGC is not the ancestral condition, and its expression is not necessarily a requirement for reducing RWL. Here we report a study of water loss rate in the ant Camponotus vicinus, measured while its DGC was slowly eliminated by gradual hypoxia (hypoxic ramp de-DGCing). Metabolic rate remained constant. The DGC ceased at a mean P(O2) of 8.4 kPa. RWL in the absence of DGCs was not affected until P(O2) declined below 3.9 kPa. Below that value, non-DGC spiracular regulation failed, accompanied by a large increase in RWL. Thus, the spiracular control strategy of the DGC is not required for low RWL, even in animals that normally express the DGC.

  12. ERRICCA radon model intercomparison exercise

    DEFF Research Database (Denmark)

    Andersen, C.E.; Albarracín, D.; Csige, I.

    1999-01-01

    -state diffusive radon profiles in dry and wet soils, (2) steady-state entry of soil gas and radon into a house, (3) time-dependent radon exhalation from abuilding-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive......, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommendedthat additional exercises are carried out....

  13. Nitrite and S-Nitrosohemoglobin Exchange Across the Human Cerebral and Femoral Circulation: Relationship to Basal and Exercise Blood Flow Responses to Hypoxia.

    Science.gov (United States)

    Bailey, Damian M; Rasmussen, Peter; Overgaard, Morten; Evans, Kevin A; Bohm, Aske M; Seifert, Thomas; Brassard, Patrice; Zaar, Morten; Nielsen, Henning B; Raven, Peter B; Secher, Niels H

    2017-01-10

    The mechanisms underlying red blood cell (RBC)-mediated hypoxic vasodilation remain controversial, with separate roles for nitrite () and S-nitrosohemoglobin (SNO-Hb) widely contested given their ability to transduce nitric oxide bioactivity within the microcirculation. To establish their relative contribution in vivo, we quantified arterial-venous concentration gradients across the human cerebral and femoral circulation at rest and during exercise, an ideal model system characterized by physiological extremes of O 2 tension and blood flow. Ten healthy participants (5 men, 5 women) aged 24±4 (mean±SD) years old were randomly assigned to a normoxic (21% O 2 ) and hypoxic (10% O 2 ) trial with measurements performed at rest and after 30 minutes of cycling at 70% of maximal power output in hypoxia and equivalent relative and absolute intensities in normoxia. Blood was sampled simultaneously from the brachial artery and internal jugular and femoral veins with plasma and RBC nitric oxide metabolites measured by tri-iodide reductive chemiluminescence. Blood flow was determined by transcranial Doppler ultrasound (cerebral blood flow) and constant infusion thermodilution (femoral blood flow) with net exchange calculated via the Fick principle. Hypoxia was associated with a mild increase in both cerebral blood flow and femoral blood flow (Pflow during exercise (Pvenous; Parterial; P0.05). These findings suggest that hypoxia and, to a far greater extent, exercise independently promote arterial-venous delivery gradients of intravascular nitric oxide, with deoxyhemoglobin-mediated reduction identified as the dominant mechanism underlying hypoxic vasodilation. © 2016 American Heart Association, Inc.

  14. The heat exchanger of small pellet boiler for phytomass

    Science.gov (United States)

    Mičieta, Jozef; Lenhard, Richard; Jandačka, Jozef

    2014-08-01

    Combustion of pellets from plant biomass (phytomass) causes various troubles. Main problem is slagging ash because of low melting temperature of ash from phytomass. This problem is possible to solve either improving energetic properties of phytomass by additives or modification of boiler construction. A small-scale boiler for phytomass is different in construction of heat exchanger and furnace mainly. We solve major problem - slagging ash, by decreasing combustion temperature via redesign of pellet burner and boiler body. Consequence of lower combustion temperature is also lower temperature gradient of combustion gas. It means that is necessary to design larger heat exchanging surface. We plane to use underfed burner, so we would utilize circle symmetry heat exchanger. Paper deals design of heat exchanger construction with help of CFD simulation. Our purpose is to keep uniform water flux and combustion gas flux in heat exchanger without zone of local overheating and excess cooling.

  15. 77 FR 47902 - Self-Regulatory Organizations; C2 Options Exchange, Incorporated; Notice of Filing and Immediate...

    Science.gov (United States)

    2012-08-10

    ... $0.0015 per contract. The Exchange is adopting an ORF due to substantial increases in resources... surveillance for position limit violations, manipulation, frontrunning, contrary exercise advice violations and... surveillance for position limit violations, manipulation, frontrunning and contrary exercise advice violations...

  16. Effect of surfactant and partial liquid ventilation treatment on gas exchange and lung mechanics in immature lambs: influence of gestational age.

    Science.gov (United States)

    Rey-Santano, Carmen; Mielgo, Victoria; Gastiasoro, Elena; Valls-i-Soler, Adolfo; Murgia, Xabier

    2013-01-01

    Surfactant (SF) and partial liquid ventilation (PLV) improve gas exchange and lung mechanics in neonatal RDS. However, variations in the effects of SF and PLV with degree of lung immaturity have not been thoroughly explored. Experimental Neonatal Respiratory Physiology Research Unit, Cruces University Hospital. Prospective, randomized study using sealed envelopes. 36 preterm lambs were exposed (at 125 or 133-days of gestational age) by laparotomy and intubated. Catheters were placed in the jugular vein and carotid artery. All the lambs were assigned to one of three subgroups given: 20 mL/Kg perfluorocarbon and managed with partial liquid ventilation (PLV), surfactant (Curosurf®, 200 mg/kg) or (3) no pulmonary treatment (Controls) for 3 h. Cardiovascular parameters, blood gases and pulmonary mechanics were measured. In 125-day gestation lambs, SF treatment partially improved gas exchange and lung mechanics, while PLV produced significant rapid improvements in these parameters. In 133-day lambs, treatments with SF or PLV achieved similarly good responses. Neither surfactant nor PLV significantly affected the cardiovascular parameters. SF therapy response was more effective in the older gestational age group whereas the effectiveness of PLV therapy was not gestational age dependent.

  17. Effects of a short-term exercise training program on aerobic fitness, fatigue, health perception and activity level of subjects with multiple sclerosis.

    Science.gov (United States)

    Mostert, S; Kesselring, J

    2002-04-01

    Multiple sclerosis (MS) patients of an inpatient rehabilitation program have been randomly assigned to an exercise training (MS-ET) or nontraining group (MS-NI). Before and after 4 weeks of aerobic exercise training, a graded maximal exercise test with measurement of gas exchange and a lung function test was administered to all 26 patients fulfilling the inclusion criteria. Activity level, fatigue and health perception were measured by means of questionnaires. Twenty-six healthy persons served as control group and were matched in respect of age, gender and activity level. Training intervention consisted of 5x30 min sessions per week of bicycle exercise with individualised intensity. Compared with baseline, the MS training group demonstrated a significant rightward placement of the aerobic threshold (AT) (VO2+13%; work rate [WR])+11%), an improvement of health perception (vitality+46%; social interaction+36%), an increase of activity level (+17%) and a tendency to less fatigue. No changes were observed for the MS-NI group and the control groups. Maximal aerobic capacity and lung function were not changed by either training or nontraining in all four groups. Overall compliance to the training program was quite low (65%), whereas incidence of symptom exacerbation by physical activity has been lower than expected (6%).

  18. Design study of plastic film heat exchanger

    Science.gov (United States)

    Guyer, E. C.; Brownell, D. L.

    1986-02-01

    This report presents the results of an effort to develop and design a unique thermoplastic film heat exchanger for use in an industrial heat pump evaporator system and other energy recovery applications. The concept for the exchanger is that of individual heat exchange elements formed by two adjoining and freely hanging plastic films. Liquid flows downward in a regulated fashion between the films due to the balance of hydrostatic and frictional forces. The fluid stream on the outside of film may be a free-falling liquid film, a condensing gas, or a noncondensing gas. The flow and structural principles are similar to those embodied in an earlier heat exchange system developed for use in waste water treatment systems (Sanderson). The design allows for high heat transfer rates while working within the thermal and structural limitations of thermoplastic materials. The potential of this new heat exchanger design lies in the relatively low cost of plastic film and the high inherent corrosion and fouling resistance. This report addresses the selection of materials, the potential heat transf er performance, the mechanical design and operation of a unit applied in a low pressure steam recovery system, and the expected selling price in comparison to conventional metallic shell and tube heat exchangers.

  19. Exchange reaction between tritiated hydrogen and water vapor

    International Nuclear Information System (INIS)

    Yamada, Koichi; Takano, Kenichi; Watanabe, Tamaki.

    1979-01-01

    Exchange reaction of tritiated hydrogen to water vapor under the condition of tritium gas concentration between 1 μCi/l and 1 mCi/l was studied. Tritium gas with hydrogen gas of 5 Torr and water of 20 mg were enclosed in a Pyrex glass ampule with volume of about 100 ml. The mixed gas with water vapor was heated with electric furnace. The heating time was between 2 and 100 hr, and the temperature was 776, 725, 675, 621, and 570.5 0 K. After heating, tritiated water was trapped with liquid nitrogen, and counted with a liquid scintillation counter. The radioactive concentration of initial tritiated hydrogen was measured with a calibrated ionization chamber. The main results obtained are as follows; 1) the concentration of produced tritiated water is well proportioned to that of initial tritiated hydrogen, 2) the activation energy of exchange reaction from tritiated hydrogen to tritiated water is 26.2 kcal/mol and that of inverse reaction is 27.4 kcal/mol, 3) the reaction rate at room temperature which calculated with activation energy is 1.04 x 10 -13 day -1 , and then exchange reaction at room temperature is negligible. (author)

  20. Seasonal variation in gas exchange by plants of Erythroxylum simonis Plowman

    Directory of Open Access Journals (Sweden)

    João Everthon da Silva Ribeiro

    2018-02-01

    Full Text Available ABSTRACT Erythroxylum simonisis an understory species found in Northeast Brazil. Due to its shaded habitat,E. simonisis subjected to seasonal oscillations of the environment, to which it must respond ecophysiologically. The objective of this study was to evaluate the effects of seasonality on the ecophysiology ofE. simonis in a fragment of Seasonal Semideciduous Forest. Leaf area index, visible sky fraction and photosynthetically active radiation were measured for 10 individuals during the dry and rainy seasons. Soil moisture, temperature and monthly precipitation were measured, as well as photosynthetic rate, stomatal conductance, internal CO2concentration, transpiration, instantaneous water use efficiency, instantaneous carboxylation efficiency and chlorophyll content. Ecophysiological variables were correlated with environmental variables, with a greater association of rainfall and soil moisture with stomatal conductance, transpiration and photosynthetic rate, indicating that water availability has an effect on the ecophysiology ofE. simonis. With the exception of instantaneous carboxylation efficiency, gas exchange exhibited significant differences among the months studied, with the highest values being for months with greater water availability, thus showing that the ecophysiology of the species responds to seasonal changes throughout the year.