WorldWideScience

Sample records for excretory urography doppler

  1. Early report: Comparison of breath-hold MR excretory urography, Doppler ultrasound and isotope renography in evaluation of symptomatic hydronephrosis in pregnancy

    International Nuclear Information System (INIS)

    Spencer, J.A.; Tomlinson, A.J.; Weston, M.J.; Lloyd, S.N.

    2000-01-01

    AIM: To compare assessment by MR excretory urography (MREU), Doppler ultrasound and isotope renography of women with symptomatic hydronephrosis in pregnancy and to define its cause. MATERIALS AND METHODS: Eleven women at 19-34 weeks of gestation were studied prospectively with gadolinium-enhanced breath-hold gradient echo MREU and transabdominal Doppler ultrasound compared with a 'gold standard' of isotope renography employing frusemide challenge. All studies were performed within 24 h, were reported independently in a blinded fashion and employed clearly defined criteria. Obstetric and infant outcomes were obtained. RESULTS: There were no adverse reactions to gadolinium administration in pregnancy and no adverse obstetric or infant outcomes. Three of the 11 women were unable to tolerate the complete MREU protocol. Ultrasound indices could not be used to predict ureteric obstruction as shown by isotope renography. MREU agreed with renographic findings in five of the six cases with obstruction and in two without obstruction. MREU directly demonstrated hydronephrosis to result from extrinsic compression of the ureter between the gravid uterus and iliopsoas muscle. CONCLUSION: MR excretory urography is a promising technique which affords equivalent functional and additional anatomical information to isotope renography. It is more accurate than Doppler ultrasound in the assessment of ureteric obstruction in pregnancy. Spencer, J. A. (2000)

  2. Changing indications for excretory urography

    International Nuclear Information System (INIS)

    Kumar, R.; Schreiber, M.H.

    1985-01-01

    Most individuals suspected of having renovascular hypertension, men with benign prostatic enlargement, women with recurrent infections of the urinary tract or urinary stress incontinence, women undergoing hysterectomy, uremic and diabetic patients, and patients with renal transplant or adult polycystic kidney disease should not, as a rule, undergo routine excretory urography (EU). Possible morbidity and mortality and unwarranted cost do not justify the study, since the majority of individuals in any of these situations do not benefit from the information obtained from the study. Excretory urography must be performed selectively, rather than routinely, in such persons. As the authors emphasize, modified EU, often using only two to three films, may be performed under many clinical situations to reduce radiation exposure, toxic effects, and cost to the patient

  3. Gd-BOPTA-enhanced excretory MR urography without administration of diuretics

    International Nuclear Information System (INIS)

    Allkemper, T.; Tombach, B.; Heindel, W.

    2001-01-01

    Purpose: To evaluate the feasibility and clinical utility of Gd-BOPTA enhanced excretory magnetic resonance urography without additional administration of diuretics in correlation with conventional urography. Method: 15 preoperative patients with pelvic tumors were examined at 1.5 T using a breath-hold high-resolution 3D-FLASH sequence during first-pass as well as 5, 10, 15 minutes after iv. injection of 0.05 mmol/kg BW Gd-BOPTA (MultiHance trademark ) without administration of diuretics. Post-processed coronal and multiplanar MIP reconstructions were compared to conventional excretory urography with regard to morphologic accuracy, anatomic variability, filling defects, cause and level of obstruction or compression, tumor visibility, and time-effectiveness by two independent radiologists. Results: Visualization of the urinary tract by MRU was comparable to conventional excretory urography in 14 of 15 cases. Caliceal fornices were better delineated on conventional urographies, whereas MRU was considered superior in the assessment of the inferior ureter sections, the urinary bladder and obstructive tumors, whose extents could be clearly marked out. Examination times of both techniques were comparable. Conclusion: These first results show that non-diuretic Gd-BOPTA enhanced MRU is comparable to conventional excretory urography for the preoperative diagnosis of pelvic tumors. Further improvements of this technique seem possible by optimization of examination intervals and injection doses. (orig.) [de

  4. Gadolinium-enhanced excretory MR urography: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lee, Jeong Min; Han, Young Min; Cheong, Gyung Ho; Oh, Hee Sul; Kim, Chong Soo; Park, Sung Kwang; Kim, Young Gon

    2000-01-01

    To compare the feasibility of gadolinium-enhanced excretory MR urography (GEMRU) and conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in patients with hydronephrosis or non-visualized kidney. Fifteen patients with hydronephrosis or non-visualized kidney, as demonstrated by ultrasonography or intravenous urography, were enrolled in this study. Nine were men and six were women, and their age ranged from 18 to 77 (mean, 60.6) years. For all MR examinations, a 1.5T MR unit was employed. For breath-hold MR urography, the HASTE technique (MRU) was used, and reconstruction involved the use of a maximum intensity-projection (MIP) algorithm. For gadolinium-enhanced excretory MR urography, the fast low angle shot (FLASH) 3-D method was used and images were obtained at 5, 10, 20, and 30 minutes, and reconstruction again involved the use of MIP algorithm. In some cases, additional GEMRU was obtained 24 hour after contrast material injection, and an MIP algorithm was used for reconstruction. MRU and GEMRU were independently interpreted by two radiologists who for quantitative analysis compared SNR with CNR, and at each anatomic level qualitatively analyzed morphologic accuracy and diagnostic value of the lesions. In quantitative analysis, SNR and CNR differences between the two sequences at the renal pelvis and the level of the ureter were not significant (p greater than 0.05). In qualitative analysis, GEMRU was superior to MRU for the assessment of evaluated ureter at each level (p less than 0.05), anatomic anomaly and intrinsic tumor. Ureteral stones, however, were more easily diagnosed with MRU. For assessment of the ureter GEMRU is superior to MRU and has the advantage of evaluating renal function. We believe that for evaluation of the urinary tract, especially the distal ureter, GEMRU may be a valuable adjunct to routine MR urography. (author)

  5. The evaluation of kidney scan: On comparison with excretory urography

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Yong Kyu; Kim, Chung Kyu; Choi, Byung Sook [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1970-10-15

    The kidney scan and the excretory urography of 21 cases in kidney disease proved clinically or pathologically at Yonsei University, Severance Hospital were reviewed and analysed briefly. Following were the results: 1. In all except 2 cases of pyelonephritis, changes on the kidney scan were noted with generalized motted density and cold area in the kidney, and with diffuse poor or non uptake density and various size or shape of the kidney. 2. On the excretory urogram, the demonstrable findings in the kidney parenchyma were discribed on the only 7 of 21 cases, hypernephroma, tuberculosis kidney, necrotizing papillits, medullary sponge kidney, and stenosis of renal artery. 3. Three of all cases, renal carbuncle, retroperitoneal hematoma with aberrant vessel and angiolipomyoma were no appreciable finding on the pyelography, but on the view of kidney scanning, there were apparently demonstrated abnormal cold area and some enlargement of kidney size. We concluded that the close correlation of the two techniques, kidney scanning and excretory urography on the kidney disease leads to more improved diagnostic accuracy.

  6. The evaluation of kidney scan: On comparison with excretory urography

    International Nuclear Information System (INIS)

    Choe, Yong Kyu; Kim, Chung Kyu; Choi, Byung Sook

    1970-01-01

    The kidney scan and the excretory urography of 21 cases in kidney disease proved clinically or pathologically at Yonsei University, Severance Hospital were reviewed and analysed briefly. Following were the results: 1. In all except 2 cases of pyelonephritis, changes on the kidney scan were noted with generalized motted density and cold area in the kidney, and with diffuse poor or non uptake density and various size or shape of the kidney. 2. On the excretory urogram, the demonstrable findings in the kidney parenchyma were discribed on the only 7 of 21 cases, hypernephroma, tuberculosis kidney, necrotizing papillits, medullary sponge kidney, and stenosis of renal artery. 3. Three of all cases, renal carbuncle, retroperitoneal hematoma with aberrant vessel and angiolipomyoma were no appreciable finding on the pyelography, but on the view of kidney scanning, there were apparently demonstrated abnormal cold area and some enlargement of kidney size. We concluded that the close correlation of the two techniques, kidney scanning and excretory urography on the kidney disease leads to more improved diagnostic accuracy

  7. Diagnostic value of combined static-excretory MR Urography in children with hydroneph

    Directory of Open Access Journals (Sweden)

    Sally Emad-Eldin

    2015-03-01

    Full Text Available The aim of this study was to determine the feasibility, accuracy and diagnostic potential of combined static-excretory MR Urography in children with sonographically detected hydronephrosis. We prospectively evaluated 28 children (11 girls and 17 boys, mean age 8.3 years (range 2 months–16 years. Static-excretory MR Urography was performed in all cases. The results of MR Urography were compared with the results of other imaging modalities, cystoscopy and surgery. In 28 children, 61 renal units were evaluated by MR Urography (the renal unit is the kidney and its draining ureter. The final diagnoses included: normal renal units (n = 23; uretropelvic junction obstruction (n = 14; megaureter (n = 8; midureteric stricture (n = 1, complicated duplicated systems (n = 5, post ESWL non-obstructive dilation (n = 2, extrarenal pelvis (n = 4, dysplastic kidney (n = 4. Complex pathology and more than one disease entity in were found in 7 children. The MRI diagnosis correlated with the final diagnosis in 57 units, with diagnostic accuracy 93.4%. In conclusions static and excretory MRU give both morphological and functional information in a single examination without exposure to ionizing radiation and iodinated contrast agent. It is a valuable imaging technique for children with upper urinary tract dilatation; especially in cases of complex congenital pathologies and severely hydronephrotic kidney.

  8. 99mtechnetium-dimercapto-succinic acid renal scanning and excretory urography in diagnosis of renal scars in children

    International Nuclear Information System (INIS)

    McLorie, G.A.; Aliabadi, H.; Churchill, B.M.; Ash, J.M.; Gilday, D.L.

    1989-01-01

    We compared the ability of excretory urography (without tomography) and 99mtechnetium-dimercapto-succinic acid renal scanning to detect renal scars in 32 children with primary vesicoureteral reflux. These children did not have hydronephrosis, renal failure or urinary tract obstruction. In all cases both studies were conducted within a 10-month period. The findings from both modalities were in agreement for 51 of the 64 renal units evaluated (80%). Evaluation of the excretory urogram indicated 6 cases of diffuse and 2 of focal scarring that were not detected by evaluation of the renal scan. The sensitivity of excretory urography to detect renal scars was 84% and the specificity was 83%. The 99mtechnetium-dimercapto-succinic acid renal scan showed 5 cases of focal renal scarring not detected by excretory urography. The sensitivity of the renal scan to detect renal scars was 77% and the specificity was 75%. We conclude that neither study alone could effectively replace the other for the detection of renal scars, and recommend that both be included in the initial evaluation and followup of patients with renal scars

  9. Diagnostic value of diuretic-enhanced excretory MR urography in patients with obstructive uropathy

    Energy Technology Data Exchange (ETDEWEB)

    Karabacakoglu, Aydin E-mail: radaydin@hotmail.com; Karakose, Serdar; Ince, Ozlem; Cobankara, Osman Ege; Karalezli, Giray

    2004-12-01

    Purpose: Ultrasonography and conventional intravenous urography are most common methods in diagnosis of obstructive uropathies. The disadvantage of ultrasonography is inability of visualizing middle and lower one thirds of ureter, while intravenous urography is using radiation, also functionally extra loading effect on kidneys. In this study, the diagnostic value of MR urography on obstructive uropathy were investigated. Materials and methods: Forty five patients who were suffered from obstructive uropathy examined by ultrasonography, intravenous urography and diuretic-enhanced excretory MR urography by using MR-contrast-agent. Results: MR urography established accuracy rate of 92.8% for stone diseases which formed the largest group in this study, however, in other causes of obstructive uropathy, MR urography provide 100% correct diagnosis. Conclusion: MR urography provide high quality images for diagnosing and determining causes of urinary obstruction defining position and severity of dilatations as well as showing localization of the pathology. We think that MR urography should be a primary investigation in patients with obstructive uropathy who have contrast agent and X-ray contrindication.

  10. Diagnostic value of diuretic-enhanced excretory MR urography in patients with obstructive uropathy

    International Nuclear Information System (INIS)

    Karabacakoglu, Aydin; Karakose, Serdar; Ince, Ozlem; Cobankara, Osman Ege; Karalezli, Giray

    2004-01-01

    Purpose: Ultrasonography and conventional intravenous urography are most common methods in diagnosis of obstructive uropathies. The disadvantage of ultrasonography is inability of visualizing middle and lower one thirds of ureter, while intravenous urography is using radiation, also functionally extra loading effect on kidneys. In this study, the diagnostic value of MR urography on obstructive uropathy were investigated. Materials and methods: Forty five patients who were suffered from obstructive uropathy examined by ultrasonography, intravenous urography and diuretic-enhanced excretory MR urography by using MR-contrast-agent. Results: MR urography established accuracy rate of 92.8% for stone diseases which formed the largest group in this study, however, in other causes of obstructive uropathy, MR urography provide 100% correct diagnosis. Conclusion: MR urography provide high quality images for diagnosing and determining causes of urinary obstruction defining position and severity of dilatations as well as showing localization of the pathology. We think that MR urography should be a primary investigation in patients with obstructive uropathy who have contrast agent and X-ray contrindication

  11. Excretory MR urography using breathhold three-dimensional FISP: comparison with MR urography using HASTE technique

    Energy Technology Data Exchange (ETDEWEB)

    Song, Won Kue; Lee, Jeong Min; Jin, Kong Young; Hwang, Ho keung; Han, Young Min [Chonbuk Narional University Hospital, Chonju (Korea, Republic of); Ym, Seong Hee [Namwon Medical Center, Chonju (Korea, Republic of)

    2000-09-01

    To compare the usefulness of gadolinium-enhanced excretory MR urography using breath-hold three-dimensional fast imaging with steady state precession (3-D FISP) with conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in the evaluation of obstructive uropathy. Twenty-three patients in whom ultrasonography (US) and/or intravenous urography (IVU) revealed signs of urinary obstruction were enrolled in this study. Fifteen were men and eight were women, and their mean age was 54 (range, 21-80) years. All MR images were obtained using a 1.5T MR unit. MR urography using the HASTE technique (MRU) and gadolinium-enhanced excretory MR urography using the 3D-FISP technique were performed, and in all cases, reconstructions involved maximum intensity projection. For contrast-enhanced MR urography(CEMRU), images were obtained 3, 5, 20, and 30 minutes after the administration of intravenous contrast media, and for selected cases, additional images were obtained until 24 hours after contrast media injection. For qualitative analysis, two experienced radiologists compared CEMRU and MRU in terms of their diagnostic value as regards the level and cause of urinary obstruction, and morphologic accuracy. In addition, signal to noise ration(SNR) and contrast to noise ration (CNR) of the urinary tract at each anatomic level were quantitatively analysed. Quantitative analysis showed that in terms of SNR and CNR of the urinary tract at the level of the mid and distal ureter, CEMRU using 3-D FISP was better than MRU using HASTE (p less than 0.05). Qualitative analysis indicated that for the depiction of the whole length of normal ureter, and detection of the level of obstruction, anatomic anomalies and intrinsic tumors, 3-D FISP was superior to HASTE. There was, however, no difference between these two modalities in the diagnosis of ureteral stone and the degree of hydronephrosis. In addition, 3-D FISP was better than HASTE for the

  12. Excretory MR urography using breathhold three-dimensional FISP: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Song, Won Kue; Lee, Jeong Min; Jin, Kong Young; Hwang, Ho keung; Han, Young Min; Ym, Seong Hee

    2000-01-01

    To compare the usefulness of gadolinium-enhanced excretory MR urography using breath-hold three-dimensional fast imaging with steady state precession (3-D FISP) with conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in the evaluation of obstructive uropathy. Twenty-three patients in whom ultrasonography (US) and/or intravenous urography (IVU) revealed signs of urinary obstruction were enrolled in this study. Fifteen were men and eight were women, and their mean age was 54 (range, 21-80) years. All MR images were obtained using a 1.5T MR unit. MR urography using the HASTE technique (MRU) and gadolinium-enhanced excretory MR urography using the 3D-FISP technique were performed, and in all cases, reconstructions involved maximum intensity projection. For contrast-enhanced MR urography(CEMRU), images were obtained 3, 5, 20, and 30 minutes after the administration of intravenous contrast media, and for selected cases, additional images were obtained until 24 hours after contrast media injection. For qualitative analysis, two experienced radiologists compared CEMRU and MRU in terms of their diagnostic value as regards the level and cause of urinary obstruction, and morphologic accuracy. In addition, signal to noise ration(SNR) and contrast to noise ration (CNR) of the urinary tract at each anatomic level were quantitatively analysed. Quantitative analysis showed that in terms of SNR and CNR of the urinary tract at the level of the mid and distal ureter, CEMRU using 3-D FISP was better than MRU using HASTE (p less than 0.05). Qualitative analysis indicated that for the depiction of the whole length of normal ureter, and detection of the level of obstruction, anatomic anomalies and intrinsic tumors, 3-D FISP was superior to HASTE. There was, however, no difference between these two modalities in the diagnosis of ureteral stone and the degree of hydronephrosis. In addition, 3-D FISP was better than HASTE for the

  13. Comparison of excretory phase, helical computed tomography with intravenous urography in patients with painless haematuria

    International Nuclear Information System (INIS)

    O'Malley, M.E.; Hahn, P.F.; Yoder, I.C.; Gazelle, G.S.; McGovern, F.J.; Mueller, P.R.

    2003-01-01

    AIM: To compare excretory phase, helical computed tomography (CT) with intravenous (IV) urography for evaluation of the urinary tract in patients with painless haematuria. MATERIALS AND METHODS: Ninety-one out-patients had IV urography followed by helical CT limited to the urinary tract. Both IV urograms and CT images were evaluated for abnormalities of the urinary tract in a blinded, prospective manner. The clinical significance of abnormalities was scored subjectively and receiver operator characteristic curve analysis was performed. RESULTS: In 69 of 91 patients (76%), no cause of haematuria was identified. In 22 of 91 patients (24%), the cause of haematuria was identified as follows: transitional cell cancer of the bladder (n=15), urinary tract stones (n=3), cystitis (n=2), haemorrhagic pyelitis (n=1) and benign ureteral stricture (n=1). With IV urography, there were 15 true-positive, seven false-negative and three false-positive interpretations. With CT, there were 18 true-positive, four false-negative and two false-positive interpretations. There was no significant difference between IV and CT urography for the significance of the positive interpretations (n=0.47). CONCLUSION: Excretory phase CT urography was comparable with IV urography for evaluation of the urinary tract in patients with painless haematuria. However, the study population did not include any upper tract cancers. O'Malley M. E. et al. (2003). Clinical Radiology 58, 294-300

  14. The diagnostic effectiveness of contrast media in the excretory urography in dogs

    International Nuclear Information System (INIS)

    Velesova, M.; Ledecky, V.

    2005-01-01

    A clinical study was conducted to investigate the use of four different positive contrast media, Omnipaque (Nycomed Imaging As.), Optiray (Maliincrodt Medical GmbH), Ultravist (Schering AG), and Urografin (Schering AG) in normograde excretory urography. Investigations were carried out on thirteen dogs. Each group of dogs was administered a different contrast medium. Radiographs were obtained immediately after the administration of contrast media and after a lapse of 5, 10 and 15 minutes. The effectiveness of the application was evaluated by assessing the radiographs of abdominal cavities in ventro-dorsal and latero-lateral positions. None of the dogs showed pronounced side effect after the application of contrast media. Ectopic ureter was diagnosed in three and a prostate cyst in one of the patients. Our results showed that Omnipaque and Ultravist were the contrast agents most suitable for the examination of the urinary apparatus by intravenous contrast excretory urography. Their advantage is that visualisation of the kidneys and ureters achieved by these media are sufficiently long and contrastive

  15. Excretory urography and ultrasonography in the diagnosis of bilateral ectopic ureters in a foal

    International Nuclear Information System (INIS)

    Blikslager, A.T.; Green, E.M.; MacFadden, K.E.; Fagin, B.; Johnson, G.C.

    1992-01-01

    A 7-week-old Appaloosa filly was admitted for persistent urinary incontinence since birth. Vaginal speculum examination revealed urine flowing from an opening in the right vaginal wall. Cytoscopy demonstrated that the ureters did not terminate at the bladder. The endoscope passed easily from the vagina directly into a dilated right ureter. An excretory urogram confirmed the vaginal termination of at least one ureter, based upon extensive filling of the vagina with contrast media in the absence of bladder filling. Bilateral hydroureter and dilated renal pelves were demonstrated both by excretory urography and by urtrasonography. Euthanasia was required by the owner in lieu of attempted surgical correction. At necroscopy, it was confirmed that the right ureter entered the vagina and the left ureter terminated at the urethra. The diagnosis of bilateral ectopic ureter in this foal was suggested by this history and clinical signs, supported by endoscopy and ultrasonography, and confirmed by excretory urography and necropsy. This case establishes the value of diagnostic imaging techniques in the antemortem diagnosis of ectopic ureter

  16. Excretory urography by subcutaneous injection of iodixanol in Persian squirrel (Sciurus anomalous)

    International Nuclear Information System (INIS)

    Veshkini, A.; Tavana, M.; Haghdost, I.S.; Masouleh, M.N.; Savojbolaghi, S.H.

    2011-01-01

    There are many indications for excretory urography in humans and animals. Intravenous urography (IVU) is the most practical method about other urography techniques are used because of difficulties for finding veins in IVU, due to small size of the patients. This study was performed to evaluate the feasibility of subcutaneous injection of iodixanol in providing a safe and diagnostic urogram in Persian squirrel. Twelve clinically healthy adult Persian squirrels were prepared and kept for two weeks prior to study. Blood tests were performed 7 days prior to the study. After eighteen hour fasting, animals were sedated by using xylazine/diazepam cocktail (xylazine 5mg/kg, diazepam 30mg/kg). Lateral and ventrodorsal control radiographs were taken. Thirteen hundred and 1800 mg iodine per kilogram body weight of iodixanol was injected subcutaneously over shoulder area in Persian squirrels (each dose for six Persian squirrels). Lateral and ventrodorsal radiographs were taken every 5 m

  17. Comprehensive renal scintillation procedures in spinal cord injury: comparison with excretory urography

    International Nuclear Information System (INIS)

    Lloyd, L.K.; Dubovsky, E.V.; Bueschen, A.J.; Witten, D.M.; Scott, J.W.; Kuhlemeier, K.; Stover, S.L.

    1981-01-01

    A 131 iodine orthoiodohippurate comprehensive renal scintillation procedure was performed and compared to results of excretory urography in 200 spinal cord injury patients. No severe urographic abnormalities were undetected by the comprehensive renal scintillation procedure. Only 1.4 per cent of renal units had greater than minimal pyelocaliectasis or ureterectasis in the presence of a normal radionuclide examination. A relatively large number of abnormalities were detected on the renal scintillation procedure when the excretory urogram was normal. Serial followup will be required to determine the significance of these findings but present data suggest that a comprehensive renal scintillation procedure and a plain film of the kidneys, ureters and bladder may be used for screening upper urinary tract abnormalities in lieu of an excretory urogram. This is particularly advantageous for the spinal cord injury population, since there have been no toxic or allergic reactions reported, no bowel preparation or dehydration is required and there is relatively low radiation exposure

  18. [Clinical application of high-pitch excretory phase images during dual-source CT urography with stellar photon detector].

    Science.gov (United States)

    Sun, Hao; Xue, Hua-dan; Jin, Zheng-yu; Wang, Xuan; Chen, Yu; He, Yong-lan; Zhang, Da-ming; Zhu, Liang; Wang, Yun; Qi, Bing; Xu, Kai; Wang, Ming

    2014-10-01

    To retrospectively evaluate the clinical feasibility of high-pitch excretory phase images during dual-source CT urography with Stellar photon detector. Totally 100 patients received dual-source CT high-pitch urinary excretory phase scanning with Stellar photon detector [80 kV, ref.92 mAs, CARE Dose 4D and CARE kV, pitch of 3.0, filter back projection reconstruction algorithm (FBP)] (group A). Another 100 patients received dual-source CT high-pitch urinary excretory phase scanning with common detector(100 kV, ref.140 mAs, CARE Dose 4D, pitch of 3.0, FBP) (group B). Quantitative measurement of CT value of urinary segments (Hounsfield units), image noise (Hounsfield units), and effective radiation dose (millisievert) were compared using independent-samples t test between two groups. Urinary system subjective opacification scores were compared using Mann-Whitney U test between two groups. There was no significant difference in subjective opacification score of intrarenal collecting system and ureters between two groups (all P>0.05). The group A images yielded significantly higher CT values of all urinary segments (all P0.05). The effective radiation dose of group A (1.1 mSv) was significantly lower than that of group B (3.79 mSv) (Ppitch low-tube-voltage during excretory phase dual-source CT urography with Stellar photon detector is feasible, with acceptable image noise and lower radiation dose.

  19. Gd-BOPTA-enhanced excretory MR urography without administration of diuretics; Gd-BOPTA-gestuetzte MR-Ausscheidungsurographie ohne Diuretikagabe

    Energy Technology Data Exchange (ETDEWEB)

    Allkemper, T.; Tombach, B.; Heindel, W. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie

    2001-02-01

    Purpose: To evaluate the feasibility and clinical utility of Gd-BOPTA enhanced excretory magnetic resonance urography without additional administration of diuretics in correlation with conventional urography. Method: 15 preoperative patients with pelvic tumors were examined at 1.5 T using a breath-hold high-resolution 3D-FLASH sequence during first-pass as well as 5, 10, 15 minutes after iv. injection of 0.05 mmol/kg BW Gd-BOPTA (MultiHance {sup trademark}) without administration of diuretics. Post-processed coronal and multiplanar MIP reconstructions were compared to conventional excretory urography with regard to morphologic accuracy, anatomic variability, filling defects, cause and level of obstruction or compression, tumor visibility, and time-effectiveness by two independent radiologists. Results: Visualization of the urinary tract by MRU was comparable to conventional excretory urography in 14 of 15 cases. Caliceal fornices were better delineated on conventional urographies, whereas MRU was considered superior in the assessment of the inferior ureter sections, the urinary bladder and obstructive tumors, whose extents could be clearly marked out. Examination times of both techniques were comparable. Conclusion: These first results show that non-diuretic Gd-BOPTA enhanced MRU is comparable to conventional excretory urography for the preoperative diagnosis of pelvic tumors. Further improvements of this technique seem possible by optimization of examination intervals and injection doses. (orig.) [German] Ziel: Abschaetzung der Durchfuehrbarkeit und des klinischen Nutzens der Gd-BOPTA-gestuetzten MR-Ausscheidungsurographie (MRU) ohne zusaetzliche Diuretikagabe im Vergleich zur konventionellen Ausscheidungsurographie. Methoden: 15 Patienten mit Beckentumoren wurden praeoperativ an einem 1.5 T-Ganzkoerpersystem mit Hilfe einer atemgehaltenen, hochaufloesenden 3D-FLASH-Sequenz unmittelbar nach intra-venoeser Applikation von 0,05 mmol/kg KG Gd-BOPTA (MultiHance {sup

  20. MR-urography and CT-urography: principles, examination techniques, applications

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.; Adam, G.; Staatz, G.; Wildberger, J.

    2003-01-01

    MR-urography (MRU) and CT-urography (CTU) provide refined imaging of the upper urinary tract not achievable with conventional intravenous urography (IVU). The traditional MR-urographic technique utilizes unenhanced, heavily T 2 -weighted turbo spin-echo sequences for obtaining static fluid images of the urinary tract independent of the excretory renal function. T 2 -weighted MR-urograms have proved to be excellent in visualizing the dilated urinary tract, even in non-excreting kidneys. In contrast, T 1 -weighted MRU reflects the excretory renal function and displays the urine flow through the upper tract after renal excretion of an intravenously administered gadolinium chelate. The gadolinium-enhanced urine is visualized with fast T 1 -weighted 3D-gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of gadolinium in the collecting system and for avoiding susceptibility artifacts (T 2 *-effects) in the urine. T 1 -weighted excretory MRU provides impressive urograms of both non-dilated and obstructed collecting systems in patients with normal or moderately impaired renal function. Multislice-CT-urography (MS-CTU) is also an excretory urography like T 1 -weighted MRU. Furthermore, MS-CTU can be combined with low-dose furosemide for accelerated passage of excreted contrast material obviating the need for abdominal compression. CT-urography is limited by its radiation burden and the nephrotoxicity of radiographic contrast media. Combining MRU or MS-CTU with conventional MRI or CT offers several applications, e.g., diagnosis of intrinsic and extrinsic tumors. Meanwhile, MRU has replaced IVU in pediatric uroradiology and is also recommended for the assessment of renal transplants. MS-CTU may provide valuable information in chronic urolithiasis, especially if associated with a distorted urinary tract anatomy. Both MRU and MS-CTU will play an important role in modern uroradiology. (orig

  1. NON-CONTRAST MAGNETIC RESONANCE UROGRAPHY

    Directory of Open Access Journals (Sweden)

    Arpita C

    2016-07-01

    Full Text Available BACKGROUND AND PURPOSE Magnetic Resonance (MR urography with its optimal contrast resolution and lack of ionizing radiation provides a comprehensive examination of the entire urinary tract noninvasively. MR urography is clinically useful in the evaluation of suspected urinary tract obstruction, haematuria, congenital anomalies, and surgically altered anatomy. It is particularly useful in cases of where there is contraindication of ionizing radiation and in paediatric and pregnant patients. The common MR urographic techniques are: Static-fluid MR urography and excretory MR urography. Static-fluid MR urography uses of heavily T2-weighted sequences to image the urinary tract as a static collection of fluid, can be repeated sequentially (Cine MR urography to better demonstrate the ureters in their entirety and to confirm the presence of fixed stenoses. Excretory MR urography is performed during the excretory phase of enhancement after the intravenous administration of gadolinium-based contrast material; thus, the patient must have sufficient renal function to allow the excretion. Static-fluid and excretory MR urography can be combined with conventional MR imaging for comprehensive evaluation of the urinary tract. The limitations are limited availability, high cost, relatively long examination time, low spatial resolution compared to IVU (Intravenous Urogram and CT Urography; sensitivity to motion (breathing and ureteral peristalsis inherent contraindications like patients with pacemakers, claustrophobia, and relative insensitivity for calcification and ureteric calculi. In this article, an attempt has been made to demonstrate the potential of static-fluid MRU to demonstrate a spectrum of urologic pathology involving the kidneys, ureters, and bladder while discussing the limitations. METHODS Thirty patients with urinary tract abnormalities were evaluated with MR urography performed between May 2014 to April 2016 using routine MR sequences and

  2. Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Tacke, J.; Adam, G.B.; Haage, P.; Guenther, R.W. [Univ. of Technology, Aachen (Germany). Dept. of Diagnostic Radiology; Jung, P.; Jakse, G. [Univ. of Technology, Aachen (Germany). Dept. of Urology

    2001-01-01

    The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p < 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. (orig.)

  3. MR-urography and CT-urography: principles, examination techniques, applications; MR-Urographie und CT-Urographie: Prinzipien, Untersuchungstechniken, Anwendungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Adam, G. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Staatz, G.; Wildberger, J. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2003-02-01

    MR-urography (MRU) and CT-urography (CTU) provide refined imaging of the upper urinary tract not achievable with conventional intravenous urography (IVU). The traditional MR-urographic technique utilizes unenhanced, heavily T{sub 2}-weighted turbo spin-echo sequences for obtaining static fluid images of the urinary tract independent of the excretory renal function. T{sub 2}-weighted MR-urograms have proved to be excellent in visualizing the dilated urinary tract, even in non-excreting kidneys. In contrast, T{sub 1}-weighted MRU reflects the excretory renal function and displays the urine flow through the upper tract after renal excretion of an intravenously administered gadolinium chelate. The gadolinium-enhanced urine is visualized with fast T{sub 1}-weighted 3D-gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of gadolinium in the collecting system and for avoiding susceptibility artifacts (T{sub 2}*-effects) in the urine. T{sub 1}-weighted excretory MRU provides impressive urograms of both non-dilated and obstructed collecting systems in patients with normal or moderately impaired renal function. Multislice-CT-urography (MS-CTU) is also an excretory urography like T{sub 1}-weighted MRU. Furthermore, MS-CTU can be combined with low-dose furosemide for accelerated passage of excreted contrast material obviating the need for abdominal compression. CT-urography is limited by its radiation burden and the nephrotoxicity of radiographic contrast media. Combining MRU or MS-CTU with conventional MRI or CT offers several applications, e.g., diagnosis of intrinsic and extrinsic tumors. Meanwhile, MRU has replaced IVU in pediatric uroradiology and is also recommended for the assessment of renal transplants. MS-CTU may provide valuable information in chronic urolithiasis, especially if associated with a distorted urinary tract anatomy. Both MRU and MS-CTU will play an important role in

  4. CT and MR urography

    International Nuclear Information System (INIS)

    Hadjidekov, G.

    2012-01-01

    Full text: Learning objectives:1) To describe the techniques of CT Urography and of MR urography; 2) To illustrate the benefit of the methods in clinical practice; 3)To present typical cases from the daily practice CT has become the mainstay of uroradiology in adults. CT urography is an excellent technique for the evaluation of urinary tract calculi, trauma, infections, complicated cysts, renal masses, having high sensitivity and specificity for both conditions facilitated by the possibilities for multiplanar imaging of the urinary system. It resembles excretory urography and consists of unenhanced, nephrographic, and pyelographic phases and can be used even as routine investigation. MR urography is a new, modern modality for evaluation of various urological abnormalities providing both morphological and functional information by means of different sequences with or without injection of gadolinium. The method is clinically useful in the evaluation of the collecting system, various variants and congenital abnormalities of the kidney, different cases of obstruction of the excretory system, tumors and inflammatory processes, hematuria. Compared to CT urography, MR urography is particularly beneficial in pediatric group or pregnant patients. It can also be performed in patients with renal insufficiency, iodine allergy and other cases of contraindications to the use of ionizing radiation. CT and MR urography are promising diagnostic methods of the wide spectrum of pathological conditions affecting the urinary tract. They are highly informative and overcome a lot of limitations of the other imaging modalities with the potential to become leading modalities to diagnose kidney diseases and other urogenital disorders.

  5. MR urography: examination techniques and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Adam, G.B.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2001-03-01

    Modern MR urography is performed on the basis of two different imaging strategies, which can be used complementarily to cover almost all aspects in the diagnosis of upper urinary tract diseases. The first technique utilizes unenhanced, heavily T2-weighted pulse sequences to obtain static-fluid images of the urinary tract. T2-weighted MR urograms have proved to be excellent in the visualization of the markedly dilated urinary tract, even if the renal excretory function is quiescent. Static-fluid MR urography is less suitable for imaging of disorders that occur in the nondilated collecting system. The second MR urography technique is analogous to the methodology of conventional intravenous pyelography and is, therefore, designated as excretory MR urography. For this purpose, a non-nephrotoxic gadolinium chelate is intravenously administered and after its renal excretion, the gadolinium-enhanced urine is visualized using fast T1-weighted gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of the contrast material inside the entire urinary tract and, secondly, to avoid high endoluminal gadolinium concentrations, which cause signal loss of the urine due to T2{sup *} effects. Gadolinium excretory MR urography allows to obtain high-quality images of both nondilated and obstructed urinary tracts in patients with normal or moderately impaired renal function. This article reviews the principles of T2- and T1-weighted MR urography in detail and informs how to use these techniques safely in potential clinical applications such as chronic urolithiasis, intrinsic and extrinsic tumor diseases, and congenital anomalies. Magnetic resonance urography performed in combination with standard MR imaging offers a potential to reduce the need for invasive retrograde pyelography. Although the economic aspect is still problematic, it is obvious that MR urography will continue to increase its role in

  6. Excretory urogramm with angiotomography: Imaging of the renal arteries by excretory urogramm

    International Nuclear Information System (INIS)

    Binder, G.

    1982-01-01

    Excretory urography permits imaging of the renal arteries up to the intrarenal ramification if the contrast medium is injected as a bolus and the time of circulation between arm vein and abdominal aorta is determined with sufficient accuracy. Imaging of the vessel phase is done using simultaneous tomography. In the experimental part of the paper phantom tests are carried through to establish the contrast medium concentration to be expected in the renal arteries by means of microdensitometry. With the aid of 100 computerized tomograms of the abdomen the layer thickness required was determined to 4.5 cm; further phantom tests provided the necessary layer distances to image renal arteries that do not run in parallel to the plain of the film. The circulation time between arm vein and abdominal aorta was measured in 180 patients using the radioisotope method. It ranges between 9 and 22 seconds. Comparisons with the Decholin-method were made. 739 renal arteries were seen during the evaluation of 343 excretory urographies with angiotomograms, in 83 per cent of the cases these arteries were presented entirely. Provided perfect execution, simultaneous tomography is a very informative method. For 212 patients the side-effects of the bolar contrast medium injection were recorded. The importance of excretory urography with combined angiotomography for the diagnosis of arterial hypertension is discussed. (orig.) [de

  7. Static-dynamic MR urography. Comparison with excretory urography and scintigraphy in experimentally induced urinary tract obstruction (UTO); Statisch-dynamische MR-Urographie. Vergleich mit Ausscheidungsurographie und Szintigraphie bei experimentell induzierter Harntransportstoerung (HTS)

    Energy Technology Data Exchange (ETDEWEB)

    Rohrschneider, W.K.; Wunsch, R.; Troeger, J. [Paediatrische Radiologie, Univ. Heidelberg (Germany); Hoffend, J. [Nuklearmedizinische Klinik, Univ. Heidelberg (Germany); Becker, K. [Inst. fuer Versuchstierkunde, Univ. Heidelberg (Germany); Darge, K.; Clorius, J.H. [Kooperationseinheit Nuklearmedizin, Deutsches Krebsforschungszentrum, Heidelberg (Germany); Kooijman, H. [Philips Medizin-Systeme, Hamburg (Germany)

    2001-02-01

    Purpose: To assess the diagnostic value of combined static-dynamic MR urography (MRU) for the functional-morphological evaluation of experimentally induced urinary tract obstruction. Methods: Static-dynamic MRU - combination study with a respiratory-triggered 3D-IR-TSE sequence and a dynamic 2D-FFE sequence after Gd-DTPA and furosemide - was obtained in comparison with {sup 99m}Tc-MAG3 diuretic renal scintigraphy (DRS), excretory urography (EU) and ultrasound (US) in 29 healthy piglets and in 20 piglets with surgically induced ureteric stenosis (total of 50 postoperative examination blocks). Results: MRU allowed complete depiction of the urinary tract in all controls, in operated piglets the stenosis was always correctly identified. Quality of MRU was superior to EU in 36 to 43 comparative studies. Calculation of single kidney function from parenchymal renograms, and assessment of urinary excretion from whole-kidney renograms resulted in a highly significant agreement of MRU with DRS. Conclusion: Static-dynamic MR urography allows excellent depiction of experimentally induced urinary tract obstruction, and reliable assessment of individual renal function and urinary excretion. Two advantages of the method stand out, it does not require radiation and it permits a functional-morphological correlation. (orig.) [German] Ziel: Einschaetzung der Wertigkeit der kombinierten statisch-dynamischen MR-Urographie (MRU) zur umfassenden funktionell-morphologischen Diagnostik tierexperimentell induzierter Harntransportstoerungen. Methodik: Die statisch-dynamische MRU-Kombination aus einer atemgetriggerten 3D-IR-TSE-Sequenz und einer dynamischen 2D-FFE-Sequenz nach Gd-DTPA und Furosemid - wurde im Vergleich zu {sup 99m}Tc-MAG3-Diurese-Nierenszintigraphie (DNS), Ultraschall (US) und Ausscheidungsurographie (AUG) bei 29 gesunden Ferkeln sowie bei 20 Ferkeln mit operativ indizierter Harnwegsstenose (insgesamt 50 postoperative Untersuchungsbloecke) durchgefuehrt. Ergebnisse: Die MRU

  8. Efficacy of the excretory urogram in the staging of gynecologic malignancies

    International Nuclear Information System (INIS)

    Hillman, B.J.; Clark, R.L.; Babbitt, G.

    1984-01-01

    It is common for patients suspected of having a gynecologic malignancy to be referred for excretory urography as part of their preoperative staging evaluation. This study investigated the efficacy of this practice using prospective and experimental retrospective interpretations of 88 urograms obtained for this clinical indication. The results indicate that excretory urography reliably depicts the ureters in most cases. However, the urogram is quite insensitive in demonstrating the extention of malignancy. The excretory urogram is useful for locating the position of the ureters and demonstrating the presence of obstruction or unsuspected urinary tract abnormalities. Nonetheless, this information also may be obtained by computed tomography, which can more accurately assess the primary mass and indicate the presence of malignant extension

  9. MDCT urography: experience with a bi-phasic excretory phase examination protocol

    International Nuclear Information System (INIS)

    Meindl, Thomas; Coppenrath, Eva; Degenhart, Christoph; Reiser, Maximilian F.; Mueller-Lisse, Ullrich G.; Mueller-Lisse, Ulrike L.

    2007-01-01

    The benefit of multidetector computed tomographic urography (MDCTU) for visualising early and late excretory phase (EP) upper urinary tract (UUT) opacification has been studied. UUT opacification was retrospectively evaluated in 45 bi-phasic four-row MDCTU examinations. The UUT was divided into intrarenal collecting system (IRCS), proximal, middle and distal ureter. Two independent readers rated opacification: 1, none; 2, partial; 3, complete. Numbers of segments and percentages of UUTs at each score were calculated for each EP and two EPs combined. Results of a single EP and of combined EPs were compared by Wilcoxon matched-pairs signed-ranks. IRCS and proximal ureter were at least partially opacified in each EP in >95%. The middle ureter was at least partially opacified in the early and late EP in 85% and 93%, respectively. The distal ureter was opacified in 65% (49/75) in the early EP and in 78% (59/75) in the late EP. Combining two EPs, non-opacified distal segments decreased to 9% (7/75). Significant improvement between a single EP and combining two EPs were found for the middle and distal ureter (P < 0.03). Bi-phasic MDCTU substantially improved opacification of the middle and distal ureter. IRCS and proximal ureter are reliably opacified with one EP. (orig.)

  10. Low tube voltage computed tomography urography using low-concentration contrast media: Comparison of image quality in conventional computed tomography urography.

    Science.gov (United States)

    Hwang, Inpyeong; Cho, Jeong Yeon; Kim, Sang Youn; Oh, Seung-June; Ku, Ja Hyeon; Lee, Joongyup; Kim, Seung Hyup

    2015-12-01

    The aim of the present study was to investigate the feasibility and image quality of excretory CT urography performed using low iodine-concentration contrast media and low tube voltage. This prospective study enrolled 63 patients who undergoing CT urography. The subjects were randomized into two groups of an excretory phase CT urography protocol and received either 240 mg I/mL of contrast media and 80 kVp of tube voltage (low-concentration protocol, n=32) or 350 mg I/mL and 120 kVp (conventional protocol, n=31). Two readers qualitatively evaluated images for sharpness of the urinary tract, image noise, streak artifact and overall diagnostic acceptability. The mean attenuation, signal-to-noise ratio, contrast-to-noise ratio and figure of merit were measured in the urinary tract. The non-inferiority test assessed the diagnostic acceptability between the two protocol groups. The low-concentration protocol showed a significantly lower effective radiation dose (3.44 vs. 5.70 mSv, Pcontrast-to-noise ratio and figure of merit were significantly higher in the low-concentration protocol along the entire urinary tract (Pcontrast media, 80 kVp tube voltage and an iterative reconstruction algorithm is beneficial to reduce radiation dose and iodine load, and its objective image quality and subjective diagnostic acceptability is not inferior to that of conventional CT urography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Renal ultrasound and excretory urography in infants and young children with urinary tract infection

    International Nuclear Information System (INIS)

    Kenda, R.; Kenig, T.; Silc, M.; Zupancic, Z.

    1989-01-01

    The main purpose of the study was to see whether excretory urography (EU) can be safely replaced by ultrasound (US) in children with urinary tract infection (UTI) younger than 6 years. 101 hospitalised children were admitted to the prospective study. They were all diagnosed as having UTI and were treated accordingly. All children had voiding cystography (VCU), EU and US done. US and EU correlated well in 94% of the cases. In all 6 cases with discrepancy between EU and US, the VCU was abnormal. Our results confirm the data from other authors, that VCU and US should be sufficient as an initial work-up on children with UTI, while EU should be done only in the cases with abnormal findings on either one or both of the former investigations. However, it should be kept in mind that some cases of parenchymal involvement or mild subpelvic stenosis can be missed using this protocol. If EU is obtained only in the cases with abnormal US and/or VCU, only 55 children (54%) in our group would have had an EU done. (orig.)

  12. Urinary stone detection and characterisation with dual-energy CT urography after furosemide intravenous injection: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Botsikas, Diomidis; Hansen, Catrina; Stefanelli, Salvatore; Becker, Christoph D.; Montet, Xavier [Geneva University Hospital, Radiology Department, Geneva (Switzerland)

    2014-03-15

    To investigate the added advantage of IV furosemide injection and the subsequent urine dilution in the detection of urinary calculi in the excretory phase of dual-source dual-energy (DE) computed tomography (CT) urography, and to investigate the feasibility of characterising the calculi through diluted urine. Twenty-three urinary calculi were detected in 116 patients who underwent DECT urography for macroscopic haematuria with a split bolus two- or three-acquisition protocol, including a true unenhanced series and at least a mixed nephrographic excretory phase. Virtual unenhanced images were reconstructed from contrast-enhanced DE data. Calculi were recorded on all series and characterised based on their X-ray absorption characteristics at 100 kVp and 140 kVp in both true unenhanced and nephrographic excretory phase series. All calculi with a diameter more than 2 mm were detected in the virtual unenhanced phase and in the nephrographic excretory phase. Thirteen of these calculi could be characterised in the true unenhanced phase and in the mixed nephrographic excretory phase. The results were strictly identical for both phases, six of them being recognised as non-uric acid calculi and seven as uric acid calculi. Mixed nephrographic excretory phase DECT after furosemide administration allows both detection and characterisation of clinically significant calculi, through the diluted urine. (orig.)

  13. CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Korobkin, M. [Dept. of Radiology, Univ. of Michigan, Ann Arbor, MI (United States)

    2005-11-15

    With the advent of multidetector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract - the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mmin diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination - MDCTU. (orig.)

  14. Single-phase dual-energy CT urography in the evaluation of haematuria

    International Nuclear Information System (INIS)

    Ascenti, G.; Mileto, A.; Gaeta, M.; Blandino, A.; Mazziotti, S.; Scribano, E.

    2013-01-01

    Aim: To assess the value of a single-phase dual-energy computed tomography (DECT) urography protocol with synchronous nephrographic–excretory phase enhancement and to calculate the potential dose reduction by omitting the unenhanced scan. Materials and methods: Eighty-four patients referred for haematuria underwent CT urography using a protocol that included single-energy unenhanced and dual-energy contrast-enhanced with synchronous nephrographic–excretory phase scans. DECT-based images [virtual unenhanced (VUE), weighted average, and colour-coded iodine overlay] were reconstructed. Opacification degree by contrast media of the upper urinary tract, and image quality of virtual unenhanced images were independently evaluated using a four-point scale. The diagnostic accuracy in detecting urothelial tumours on DECT-based images was determined. The dose of a theoretical dual-phase single-energy protocol was obtained by multiplying the effective dose of the unenhanced single-energy acquisition by two. Radiation dose saving by omitting the unenhanced scan was calculated. Results: The degree of opacification was scored as optimal or good in 86.9% of cases (k = 0.72); VUE image quality was excellent or good in 83.3% of cases (k = 0.82). Sensitivity, specificity, positive predictive value, and negative predictive value for urothelial tumours detection were 85.7, 98.6, 92.3, and 97.1%. Omission of the unenhanced scan led to a mean dose reduction of 42.7 ± 5%. Conclusion: Single-phase DECT urography with synchronous nephrographic–excretory phase enhancement represents an accurate “all-in-one’’ approach with a radiation dose saving up to 45% compared with a standard dual-phase protocol.

  15. Appearances of the circumcaval ureter on excretory urography and MR urography: A single-center case series

    Directory of Open Access Journals (Sweden)

    Prakash Muthusami

    2013-01-01

    Full Text Available Objectives: To describe Magnetic Resonance Urography (MRU appearances of the circumcaval ureter, a rare congenital cause of hydronephrosis. Materials and Methods: Seven cases of circumcaval ureter, suspected on intravenous urography (IVU, underwent subsequent static MRU using heavily T2-weighted sequences. Results: The various appearances of circumcaval ureter on IVU and MRU were studied and compared. The circumcaval portion of the ureter was especially well seen on axial MRU sections, though this portion was routinely not visualized on IVU. In one case with a ureteric calculus, MRU also depicted a circumcaval course of the ureter, thus providing a complete diagnosis. In yet another case, where a circumcaval ureter was suspected on IVU, MRU proved the actual cause of ureteric obstruction to be a crossing vessel. Conclusion: Static MRU using heavily T2-weighted coronal and axial sequences can make or exclude the diagnosis of circumcaval ureter unequivocally.

  16. Single-phase dual-energy CT urography in the evaluation of haematuria.

    Science.gov (United States)

    Ascenti, G; Mileto, A; Gaeta, M; Blandino, A; Mazziotti, S; Scribano, E

    2013-02-01

    To assess the value of a single-phase dual-energy computed tomography (DECT) urography protocol with synchronous nephrographic-excretory phase enhancement and to calculate the potential dose reduction by omitting the unenhanced scan. Eighty-four patients referred for haematuria underwent CT urography using a protocol that included single-energy unenhanced and dual-energy contrast-enhanced with synchronous nephrographic-excretory phase scans. DECT-based images [virtual unenhanced (VUE), weighted average, and colour-coded iodine overlay] were reconstructed. Opacification degree by contrast media of the upper urinary tract, and image quality of virtual unenhanced images were independently evaluated using a four-point scale. The diagnostic accuracy in detecting urothelial tumours on DECT-based images was determined. The dose of a theoretical dual-phase single-energy protocol was obtained by multiplying the effective dose of the unenhanced single-energy acquisition by two. Radiation dose saving by omitting the unenhanced scan was calculated. The degree of opacification was scored as optimal or good in 86.9% of cases (k = 0.72); VUE image quality was excellent or good in 83.3% of cases (k = 0.82). Sensitivity, specificity, positive predictive value, and negative predictive value for urothelial tumours detection were 85.7, 98.6, 92.3, and 97.1%. Omission of the unenhanced scan led to a mean dose reduction of 42.7 ± 5%. Single-phase DECT urography with synchronous nephrographic-excretory phase enhancement represents an accurate "all-in-one'' approach with a radiation dose saving up to 45% compared with a standard dual-phase protocol. Copyright © 2012 The Royal College of Radiologists. All rights reserved.

  17. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  18. Delineation of upper urinary tract segments at MDCT urography in patients with extra-urinary mass lesions: retrospective comparison of standard and low-dose protocols for the excretory phase of imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, Ulrike L. [University of Munich, Department of Urology, Munich (Germany); University of Munich Medical School, Department of Urology, Muenchen (Germany); Coppenrath, Eva M.; Meindl, Thomas; Degenhart, Christoph; Scherr, Michael K.; Reiser, Maximilian F.; Mueller-Lisse, Ullrich G. [University of Munich, Department of Radiology, Munich (Germany); Stief, Christian G. [University of Munich, Department of Urology, Munich (Germany)

    2011-02-15

    Excretory-phase CT urography (CTU) may replace excretory urography in patients without urinary tumors. However, radiation exposure is a concern. We retrospectively compared upper urinary tract (UUT) delineation in low-dose and standard CTU. CTU (1-2 phases, 120 KV, 4 x 2.5 mm, pitch 0.875, i.v. non-ionic contrast media, iodine 36 g) was obtained with standard (14 patients, n = 27 UUTs, average 175.6 mAs/slice, average delay 16.8 min) or low-dose (26 patients, n = 86 UUTs, 29 mAs/slice, average delay 19.6 min) protocols. UUT was segmented into intrarenal collecting system (IRCS), upper, middle, and lower ureter (UU,MU,LU). Two independent readers (R1,R2) graded UUT segments as 1-not delineated, 2-partially delineated, 3-completely delineated (noisy margins), 4-completely delineated (clear margins). Chi-square statistics were calculated for partial versus complete delineation and complete delineation (clear margins), respectively. Complete delineation of UUT was similar in standard and low-dose CTU (R1, p > 0.15; R2, p > 0.2). IRCS, UU, and MU clearly delineated similarly often in standard and low-dose CTU (R1, p > 0.25; R2, p > 0.1). LU clearly delineated more often in standard protocols (R1, 18/6 standard, 38/31 low-dose, p > 0.1; R2 18/6 standard, 21/48 low-dose, p < 0.05). Low-dose CTU sufficiently delineated course of UUT and may locate obstruction/dilation, but appears unlikely to find intraluminal LU lesions. (orig.)

  19. The changing scene of radiology: Value of urography as initial examination in infectious and hypertensive disease, hematuria and malignant disease

    International Nuclear Information System (INIS)

    Goethlin, J.H.; Gadeholt, G.; Hoeiem, L.; Aslaksen, A.

    1988-01-01

    Four to 20% positive findings were found in a review of 1913 excretory urographics. Possibly relevant findings were 20% in patients referred for infectious disease, 10% in hypertensive disease, 6% in hematuria and 4% in neoplasms. Urography influenced treatment mainly in the 2 groups with few positive findings. The costs for positive findings may be acceptable in patients with hematuria or suspicion of neoplasms, but are too high in the other groups. Until ultrasonography can replace intravenous urography as the first screening method in upper urinary tract disease, the patient selection for urography in infectious and hypertensive disease should be improved. (orig.)

  20. Digital radiography versus conventional radiography during excretory urography: our experience

    International Nuclear Information System (INIS)

    Cervi, P.M.; Bighi, S.; Merlo, L.; Lupi, L.; Vita, G.

    1990-01-01

    The authors describe a computed radiographic system employed to generate and archive digital images in intravenous urography. For each exposure the system produces two digital images: the first (left image) simulates a conventional screen-film radiograph, the second (right image); enhances some spatial frequencies and emphasizes the margins of the structures. These images can be modified in their chief parameters and then printed by a laser-printer and archived on optical disks. Four experienced radiologists evaluated digital images with regard to some chief diagnostic parameters and, in 50 patients, they compared digital images with conventional screen-film radiographs and submitted the results to statistical analysis. For some of the chosen parameters, particularly for the evaluation of renal margins before and after contrast medium injection, digital images gave statistically better results than conventional films, while, no statistically significant different was observed for the other parameters. From the results of this preliminary study digital radiography was found to be useful in intravenous urography by reducing the patient's exposition dose, by always obtaining images of good quality, and by enhancing some particular features of the standard image; on the other hand there were many unsolved problems regarding the communicating and archiving system (PACS), because of the slowness of the image transfer procedure, difficulties in data transmission and complexity of referential procedures

  1. Functional MR urography in patients with renal transplants

    International Nuclear Information System (INIS)

    Knopp, M.V.; Doersam, J.; Oesingmann, N.; Piesche, S.; Hawighorst, H.; Wiesel, M.; Schad, L.R.; Kaick, G. van

    1997-01-01

    Purpose: To assess the value of functional magnetic resonance urography for the noninvasive postoperative evaluation of renal transplants. Methods: A saturation inversion projection sequence allows the selective imaging of strongly T1 weighted signal from the MR contrast agent. A coronal slab leads to images comparable to conventional urography which can be acquired as a sequence with four images per minute. Results: 15 patients with urologic questionable findings after renal transplantation were studied. FMRU revealed in 6 patients normal findings, in 6 moderate dilatation of the renal pelvis without any urodynamic relevant obstruction. 3 pathologic findings, ureteral leak, ureteropelvic-junction obstruction and ureteral stenosis were diagnosed and consequently surgically treated. The imaging quality in all studies was diagnostic and urologically relevant. Conclusion: FMRU can be used as a noninvasive technique for the assessment of renal transplant in cases with suspicion of complication in the excretory system. (orig.) [de

  2. CT urography in women with primary or recurrent pelvic tumors. Background and initial experiences; CT-Urographie bei Frauen mit primaeren oder rezidivierenden Beckentumoren. Hintergrund und erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Seifert, S.; Mueller-Lisse, U.G.; Degenhart, C.; Mourched, F.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Innenstadt, Institut fuer Klinische Radiologie, Muenchen (Germany); Jundt, K. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Innenstadt, Klinik und Poliklinik fuer Gynaekologie und Geburtshilfe, Muenchen (Germany); Stief, C.G.; Mueller-Lisse, U.L. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Innenstadt, Klinik und Poliklinik fuer Urologie, Muenchen (Germany)

    2011-07-15

    Malignant tumors of the female pelvis account for 12-13% of newly diagnosed solid neoplasms among women in the USA and Germany. German guidelines advocate diagnostic imaging for local recurrence and metastasis while there are no recommendations for primary tumors. As excretory urography has been replaced by the excretory phase of computed tomography urography (CTU) in many institutions, two independent observers retrospectively evaluated CTUs of primary or recurrent female pelvic tumors to rule out associations between CTU findings and subsequent urologic measures. Among 31 CTUs of 27 women (age 29-84 years, mean 57 years) with 15 primary and 13 recurrent tumors, 83-100% of unremarkable proximal, middle and distal ureter segments were completely delineated in the excretory phase (delay 6-29 min, mean 16 min). The most common pathological findings included distal ureter obstruction (n=19, 61%), bladder compression (n=13, 42%) and bladder invasion (n=8, 26%). Out of 20 pathologically altered urinary tracts 8 were subsequently subjected to urologic measures (2-tailed Fisher exact test, p=0.0215) but none of the 10 unremarkable urinary tracts were treated. It appears that CTU is a sensible pre-therapeutic test for the urinary tract for primary and recurrent female pelvic tumors. (orig.) [German] Maligne Beckentumoren stellen 12-13% aller neu diagnostizierten soliden Neoplasien bei Frauen in den USA und in Deutschland dar. Deutsche Leitlinien befuerworten bildgebende Untersuchungen bei Lokalrezidiven und Metastasen; fuer Primaertumoren gibt es keine einschlaegigen Empfehlungen. Da das Ausscheidungsurogramm durch die Ausscheidungsaufnahme der CT-Urographie (CTU) weitgehend abgeloest ist, wurde bei weiblichen Beckentumoren oder deren Rezidive der Zusammenhang zwischen CTU-Befunden und nachfolgenden operativen urologischen Massnahmen retrospektiv von 2 unabhaengigen Auswertern geprueft. Bei 31 CTUs von 27 Frauen (Alter 29-84, Median 57 Jahre) mit 15 Primaertumoren und 13

  3. Magnetic resonance urography in the assessment of hydronephrosis and hydroureter in children

    International Nuclear Information System (INIS)

    Hadjidekov, V.

    2011-01-01

    MR urography is a new, modern modality for evaluation of various urological abnormalities in children. The goal of this article is to describe the role of MR urography in the assessment of hydronephrosis and hydroureters. MRU is most commonly applied to the evaluation of hydronephrosis and provides valuable insight into a wide range of obstructive uropathies. In our study we investigate 96 children with suspected abnormalities of the upper urinary tract. Using static and excretory MRU we obtain both morphological and functional information by means of different sequences with or without injection of gadolinium. MR urography is promising diagnostic method of wide spectrum of pathological conditions affecting the urinary tract with potential to revolutionize uroradiology imaging in children. It integrates exquisite anatomical information with a variety of functional data and avoids ionizing radiation. MRU is increasingly employed as a problem solver when conventional imaging studies remain inconclusive and overcomes a lot of their limitations with the potential to become in the future leading modality to diagnose diseases of the kidney especially in newborns and children. (authors)

  4. Experiences in excretion urography using iohexol

    Energy Technology Data Exchange (ETDEWEB)

    Russmann, D

    1986-07-14

    The non-ionic contrast medium Iohexol (Omnipaque 300) was used on 125 patients during intravenous excretory urography within the framework of a multicentric study. One third of the patients had already, according to careful anamnesis, experienced allergic reactions; 8% of these had experienced incompatibility after application of a contrast medium. After a short 50 ml or 100 ml infusion, an insignificant general reaction in only one patient could be observed, which abated after a short period. The other 124 patients remained completely free of symptoms. The contrast density achieved was good throughout, during which a mean contrast quantity of approx. 75 ml proved to be the optimum dosage, taking into consideration certain questions and constitution parameters of the patients.

  5. Comparison of post contrast CT urography phases in bladder cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Helenius, Malin; Dahlman, Par; Lonnemark, Maria; Magnusson, Anders [Uppsala University Hospital, Department of Surgical Sciences, Section of Radiology, Uppsala (Sweden); Brekkan, Einar [Uppsala University Hospital, Department of Surgical Sciences, Section of Urology, Uppsala (Sweden); Wernroth, Lisa [Uppsala University Hospital, Uppsala Clinical Research Center, Uppsala (Sweden)

    2016-02-15

    The aim of this study was to investigate which post-contrast phase(s) in a four-phase CT urography protocol is (are) most suitable for bladder cancer detection. The medical records of 106 patients with visible haematuria who underwent a CT urography examination, including unenhanced, enhancement-triggered corticomedullary (CMP), nephrographic (NP) and excretory (EP) phases, were reviewed. The post-contrast phases (n = 318 different phases) were randomized into an evaluation order and blindly reviewed by two uroradiologists. Twenty-one patients were diagnosed with bladder cancer. Sensitivity for bladder cancer detection was 0.95 in CMP, 0.83 in NP and 0.81 in EP. Negative predictive value (NPV) was 0.99 in CMP, 0.96 in NP and 0.95 in EP. The sensitivity was higher in CMP than in both NP (p-value 0.016) and EP (p-value 0.0003). NPV was higher in CMP than in NP (p-value 0.024) and EP (p-value 0.002). In the CT urography protocol with enhancement-triggered scan, sensitivity and NPV were highest in the corticomedullary phase, and this phase should be used for bladder assessment. (orig.)

  6. Comparison of post contrast CT urography phases in bladder cancer detection

    International Nuclear Information System (INIS)

    Helenius, Malin; Dahlman, Par; Lonnemark, Maria; Magnusson, Anders; Brekkan, Einar; Wernroth, Lisa

    2016-01-01

    The aim of this study was to investigate which post-contrast phase(s) in a four-phase CT urography protocol is (are) most suitable for bladder cancer detection. The medical records of 106 patients with visible haematuria who underwent a CT urography examination, including unenhanced, enhancement-triggered corticomedullary (CMP), nephrographic (NP) and excretory (EP) phases, were reviewed. The post-contrast phases (n = 318 different phases) were randomized into an evaluation order and blindly reviewed by two uroradiologists. Twenty-one patients were diagnosed with bladder cancer. Sensitivity for bladder cancer detection was 0.95 in CMP, 0.83 in NP and 0.81 in EP. Negative predictive value (NPV) was 0.99 in CMP, 0.96 in NP and 0.95 in EP. The sensitivity was higher in CMP than in both NP (p-value 0.016) and EP (p-value 0.0003). NPV was higher in CMP than in NP (p-value 0.024) and EP (p-value 0.002). In the CT urography protocol with enhancement-triggered scan, sensitivity and NPV were highest in the corticomedullary phase, and this phase should be used for bladder assessment. (orig.)

  7. Imaging

    International Nuclear Information System (INIS)

    Kellum, C.D.; Fisher, L.M.; Tegtmeyer, C.J.

    1987-01-01

    This paper examines the advantages of the use of excretory urography for diagnosis. According to the authors, excretory urography remains the basic radiologic examination of the urinary tract and is the foundation for the evaluation of suspected urologic disease. Despite development of the newer diagnostic modalities such as isotope scanning, ultrasonography, CT, and magnetic resonsance imaging (MRI), excretory urography has maintained a prominent role in ruorradiology. Some indications have been altered and will continue to change with the newer imaging modalities, but the initial evaluation of suspected urinary tract structural abnormalities; hematuria, pyuria, and calculus disease is best performed with excretory urography. The examination is relatively inexpensive and simple to perform, with few contraindictions. Excretory urography, when properly performed, can provide valuable information about the renal parenchyma, pelvicalyceal system, ureters, and urinary bladder

  8. Prolonged CT urography in duplex kidney.

    Science.gov (United States)

    Gong, Honghan; Gao, Lei; Dai, Xi-Jian; Zhou, Fuqing; Zhang, Ning; Zeng, Xianjun; Jiang, Jian; He, Laichang

    2016-05-13

    Duplex kidney is a common anomaly that is frequently associated with multiple complications. Typical computed tomography urography (CTU) includes four phases (unenhanced, arterial, parenchymal and excretory) and has been suggested to considerably aid in the duplex kidney diagnosi. Unfortunately, regarding duplex kidney with prolonged dilatation, the affected parenchyma and tortuous ureters demonstrate a lack of or delayed excretory opacification. We used prolonged-delay CTU, which consists of another prolonged-delay phase (1- to 72-h delay; mean delay: 24 h) to opacify the duplicated ureters and affected parenchyma. Seventeen patients (9 males and 8 females; age range: 2.5-56 y; mean age: 40.4 y) with duplex kidney were included in this study. Unenhanced scans did not find typical characteristics of duplex kidney, except for irregular perirenal morphology. Duplex kidney could not be confirmed on typical four-phase CTU, whereas it could be easily diagnosed in axial and CT-3D reconstruction using prolonged CTU (prolonged-delay phase). Between January 2005 and October 2010, in this review board-approved study (with waived informed consent), 17 patients (9 males and 8 females; age range: 2.5 ~ 56 y; mean age: 40.4 y) with suspicious duplex kidney underwent prolonged CTU to opacify the duplicated ureters and confirm the diagnosis. Our results suggest the validity of prolonged CTU to aid in the evaluation of the function of the affected parenchyma and in the demonstration of urinary tract malformations.

  9. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  10. CT urography in the diagnosis of renal masses in patients with hematuria

    International Nuclear Information System (INIS)

    Warshauer, D.M.; Street, L.; McCarthy, S.M.; Glickman, M.G.; Ritcher, J.; Rosenfield, A.T.

    1987-01-01

    The optimal method for the diagnosis of renal masses in patients with hematuria has been in question since the introduction of axial imaging techniques. A prospective study comparing excretory urography and nephrotomography (EU) with limited renal CT was undertaken. Results showed EU able to detect approximately 75% of CT-confirmed masses greater than 2 cm, but less than 10% of CT masses smaller than 2 cm. These results suggest that a combination study of CT/EU utilizing a single contrast injection with EU for imaging the collecting system and CT for renal parenchymal evaluation would be the best screening study in patients with hematuria

  11. Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method

    Energy Technology Data Exchange (ETDEWEB)

    You, Shan [Hebei North University, Department of Graduate, Zhangjiakou City, Hebei Province (China); Ma, XianWu; Zhang, ChangZhu; Li, Qiang [Qiqihar Chinese Medicine Hospital, Department of Radiology, Qigihar City, Heilongjiang Province (China); Shi, WenWei; Zhang, Jing; Yuan, XiaoDong [The 309th Hospital of Chinese People' s Liberation Army, Department of Radiology, Beijing (China)

    2018-03-15

    To present a single-kidney CT-GFR measurement and compare it with the renal dynamic imaging Gates-GFR. Thirty-six patients with hydronephrosis referred for CT urography and 99mTc-DTPA renal dynamic imaging were prospectively included. Informed consent was obtained from all patients. The CT urography protocol included non-contrast, nephrographic, and excretory phase imaging. The total CT-GFR was calculated by dividing the CT number increments of the total urinary system between the nephrographic and excretory phase by the products of iodine concentration in the aorta and the elapsed time, then multiplied by (1- Haematocrit). The total CT-GFR was then split into single-kidney CT-GFR by a left and right kidney proportionality factor. The results were compared with single-kidney Gates-GFR by using paired t-test, correlation analysis, and Bland-Altman plots. Paired difference between single-kidney CT-GFR (45.02 ± 13.91) and single-kidney Gates-GFR (51.21 ± 14.76) was 6.19 ± 5.63 ml/min, p<0.001, demonstrating 12.1% systematic underestimation with ±11.03 ml/min (±21.5%) measurement deviation. A good correlation was revealed between both measurements (r=0.87, p<0.001). The proposed single-kidney CT-GFR correlates and agrees well with the reference standard despite a systematic underestimation, therefore it could be a one-stop-shop for evaluating urinary tract morphology and split renal function. (orig.)

  12. Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method

    International Nuclear Information System (INIS)

    You, Shan; Ma, XianWu; Zhang, ChangZhu; Li, Qiang; Shi, WenWei; Zhang, Jing; Yuan, XiaoDong

    2018-01-01

    To present a single-kidney CT-GFR measurement and compare it with the renal dynamic imaging Gates-GFR. Thirty-six patients with hydronephrosis referred for CT urography and 99mTc-DTPA renal dynamic imaging were prospectively included. Informed consent was obtained from all patients. The CT urography protocol included non-contrast, nephrographic, and excretory phase imaging. The total CT-GFR was calculated by dividing the CT number increments of the total urinary system between the nephrographic and excretory phase by the products of iodine concentration in the aorta and the elapsed time, then multiplied by (1- Haematocrit). The total CT-GFR was then split into single-kidney CT-GFR by a left and right kidney proportionality factor. The results were compared with single-kidney Gates-GFR by using paired t-test, correlation analysis, and Bland-Altman plots. Paired difference between single-kidney CT-GFR (45.02 ± 13.91) and single-kidney Gates-GFR (51.21 ± 14.76) was 6.19 ± 5.63 ml/min, p<0.001, demonstrating 12.1% systematic underestimation with ±11.03 ml/min (±21.5%) measurement deviation. A good correlation was revealed between both measurements (r=0.87, p<0.001). The proposed single-kidney CT-GFR correlates and agrees well with the reference standard despite a systematic underestimation, therefore it could be a one-stop-shop for evaluating urinary tract morphology and split renal function. (orig.)

  13. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  14. Comparison of excretory urographic contrast effects of dimeric and monomeric non-ionic iodinated contrast media in dogs

    International Nuclear Information System (INIS)

    Kishimoto, M.; Yamada, K.; Watanabe, A.; Miyamoto, K.; Iwasaki, T.; Miyake, Y.

    2007-01-01

    In excretory urography, the osmolarity of contrast media has rarely been treated as important in veterinary medicine. In this study, the contrast effect of two contrast media (monomeric iohexol and dimeric iodixanol) in the renal cortex and aorta were compared using computed tomography (CT). Five beagle dogs were used and the study employed a cross-over method for each contrast media. The results showed that there was no difference between the media in the aorta, but iodixanol showed higher CT value and a longer contrast effect than iohexol in the renal cortex, in spite of having the same iodine dosage. It is believed that iodixanol, with its low osmolarity, is diluted less by osmotic diuresis than monomeric iohexol. It is important to consider the osmolarity of the contrast media when evaluating the contrast effect, and it is essential to use the same contrast media for each examination, or the renal excretory speed will be under/overestimated

  15. Ultrasonography versus intravenous urography

    International Nuclear Information System (INIS)

    Aslaksen, A.

    1991-01-01

    The present study was performed to compare the clinical value of urography and ultrasonography in a non-selected group of patients referred for urography to a university hospital. The conslusions and clinical implications of the study are as follows: Intravenous urography remains the cornerstone imaging examination in the evaluation of ureteral calculi. Ultrasonography is a valuable adjunct in cases of non- visualization of the kidneys, in distal obstruction and known contrast media allergy. When women with recurrent urinary tract infection are referred for imaging of the urinary tract, ultrasonography should be used. Ultrasonography should replace urography for screening of non-acute hydronephrosis like in female genital cancer and benign prostate hyperplasia. There is good correlation between urography and ultrasonography in assessing the degree of hydronephrosis. However, more researh on the relationship between hydronephrosis and obstruction is necessary. Ultrasonography should be used as the only imaging method of the upper urinary tract in patients with microscopic hematuria. In patients less than 50 years with macroscopic hematuria, ultrasonography should be used as the only imaging of the upper urinary tract, and an examination of the urinary bladder should be included. In patients over 50 years, urography supplied with ultrasonography should be used, but more research is necessary on the subject of imaging method and age. 158 refs

  16. Predictive value of excretory urography, ultrasonography, computerized tomography, and liver and bone scan in the staging of bilharzial bladder cancer in Saudi Arabia

    International Nuclear Information System (INIS)

    Hanash, K.A.; Bissada, N.K.; Abla, A.; Esmail, D.; Dowling, A.

    1984-01-01

    The role of ultrasonography, computed tomography (CT), and radioisotopic scanning in the staging of bilharzial bladder cancer has not been reported previously. Forty patients with invasive bladder cancer seen at the King Faisal Specialist Hospital and Research Centre between January 1978 and June 1981 underwent complete preoperative workup for staging of their tumors prior to radical cystectomy. The preoperative radiologic investigations included excretory urography (IVP), ultrasonography (US), CT of the pelvis, and liver and bone scans. The results of these investigations were compared with the operative and pathologic staging. Ninety-three percent of the patients with bilharzial cancer had evidence of ureteric obstruction on IVP compared with 22% of the nonbilharzial cancer patients. The presence of ureteric obstruction in these patients did not correlate with the stage of the disease with 83% of the patients with superficial tumors (T1 and T2) having hydroureteronephrosis. Ultrasonography and CT had an 83% accuracy in the staging of superficial tumors. Stage T3 tumors were understaged in 14% of the cases. Ultrasonography did not differentiate Stages T3 and T4 tumors while CT scan differentiated these two stages in 57% of the cases. Bone scan failed to reveal evidence of metastatic disease in any of the bilharzial cancer patients. Liver scan was suspicious for liver metastases in two patients with bilharzial cancers in whom open liver biopsy revealed only hepatic bilharziasis. Of all the radiographic studies, US or preferably CT scan seem to be of some value in the staging of bilharzial tumors localized to the bladder. Bone and liver scans are probably of no cost effective benefit

  17. The effect of CT urography in the diagnosis of non-calculous urinary obstruction diseases

    International Nuclear Information System (INIS)

    Zhang Zhuiyang; Shen Yuanliang; Li Xin; Cao Rongmei; Xu Xiqi; Dong Jian; Hua Dongying

    2004-01-01

    Objective: To evaluate the diagnostic effect of CT urography (CTU) in patients with non-calculous obstructive diseases of urinary tract. Methods: Forty cases with non-calculous urinary obstruction underwent helical CT during nephrographic and excretory phases. Three dimensional CTU was obtained with the reconstruction of excretory phase axial images through the workstation. Results: 24 of 40 cases with benign obstruction had a slight or severe urinary dilation. Among them,18 congenital urinary malformations showed specific findings. Four ureteric inflammations revealed a gradual taper of the lumen just like a beak, and another two prostatic hypertrophy appeared oval impression upon the middle of the posterior bladder. Six intrinsic and 10 extrinsic tumors were seen irregular filling defects of the urinary tracts as well as soft tissue mass surrounding the obstructive site, accompanied by the middle urinary dilation in 12 cases and severe in four. Meanwhile, bilateral ureterohydronephroses were also found in four extrinsic tumors. In six patients with unilateral nonfunctioning urinary tracts, CTU could be imaged with minimum intensity projection (MinIP) and then be merged with contralateral maximum intensity projection (MaxIP). Conclusion: CTU is an effective modality in the evaluation of non-calculous urinary obstruction diseases. (authors)

  18. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W.

    2010-01-01

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p ≤ 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p ≤ 0.001) and continuous opacification of the urinary tract (p ≤ 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  19. Assaying the character and stenosis of the pyeloureteric segment in nephrolithiasis through pharmacologic modification of the imaging methods

    International Nuclear Information System (INIS)

    Yudin, L.; Reznichenko, A.; Budkevich, Yu.; Shejretova, E.

    1994-01-01

    The study is performed with 17 patients presenting nephrolithiasis and 6 - hydronephrosis with stenosis of the pyeloureteric segment, confirmed intraoperatively. The character of stenosis (reversible or irreversible) is determined by ultrasonography with furosemide, dynamic scintigraphy with furosemide and progesterone, and excretory urography with progesterone. As shown by the obtained results, the pharmacologic modifications of imaging methods prove more informative in hydronephrosis, and to a lesser extent in nephrolithiasis patients. Dynamic scintigraphy with furosemide and excretory urography with progesterone yields less information, in comparison to ultrasonography with forosemid and excretory urography with progesterone. However, the comparatively limited number of patients investigated should be borne in mind. 2 tabs., 5 refs

  20. MR urography of obstructive uropathy: diagnostic value of the method in selected clinical groups

    Energy Technology Data Exchange (ETDEWEB)

    Zielonko, J.; Studniarek, M. [Department of Radiology, Institute of Radiology and Nuclear Medicine, Medical University of Gdansk, Debinki 7, 80-211 Gdansk (Poland); Markuszewski, M. [Department of Radiology, Clinical Hospital No. 3, Kieturakisa 1, 80-742 Gdansk (Poland)

    2003-04-01

    The aim of the study was to evaluate the role of MR urography (MRU) in the diagnosis of obstructive uropathy in selected groups of patients. The groups involved following pathologies: calculi; strictures of ureteropelvic junction (UPJ); benign and malignancy-induced ureterostenosis. Sixty patients with clinical diagnosis of obstructive uropathy were subjected to static fluid MRU (sMRU) with the use of 3D turbo spin echo (TSE) sequence in a 0.5-T magnet. The examination was completed with conventional MR sequences and in 12 cases additionally with sequences after the administration of Gd-DTPA and excretory MRU. The results were compared with intravenous urography (IVU), CT, US, clinical and histopathological data. The degree of the urinary tract dilatation as well as the level and type of obstruction were estimated. In patients with urolithiasis sMRU correctly depicted the degree of ureterohydronephrosis in 85%, in cases of UPJ stenosis and malignancy-induced ureterostenosis in 100% and in the group of benign ureterostenosis in 91% of patients. Determination of obstruction level in patients with stones was adequate in 92% and in cases of non-calculous ureteral strictures in 100% of patients. The sMRU sequence alone could not specify the nature of obstruction except 1 case of bladder carcinoma. Filling defects in ureters visible on MR urograms were verified with IVU or CT to exclude intrinsic tumours. Completed with conventional MR sequences sMRU enabled the depiction of solid mass or infiltration in 83% cases of malignancy-induced ureterostenosis, and in the remaining groups of patients neoplastic process was excluded in 91%. In conjunction with excretory MRU and conventional MR images sMRU appears to be a highly useful technique in assessment of obstructive uropathy, especially that of non-calculous origin. Among different clinical applications MRU is superior in the evaluation of dilated urinary tract in altered anatomical conditions (e.g. in patients with ileal

  1. Imaging of hematuria.

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-10-01

    OBJECTIVE: In this article, we will discuss the current status of imaging in patients with hematuria of urologic origin. Issues impacting evaluation of these patients with radiography, excretory urography, retrograde pyelography, and sonography will be discussed. CONCLUSION: Conventional radiography has no role in the detection of renal or urothelial carcinoma. Low-dose CT offers much greater sensitivities for the detection of urinary tract calculi than radiography at doses equivalent to conventional radiography. Ultrasound alone is insufficient for imaging of hematuria. Using ultrasound alone, it is often difficult to differentiate renal transitional cell carcinoma from other causes of filling defects of the renal collecting system such as blood clots, sloughed papillae, or fungus balls. The prominence of the role of excretory urography in the evaluation of patients with hematuria has diminished, and MDCT urography is now preferred to excretory urography in most cases.

  2. Combined static-dynamic MR urography for the simultaneous evaluation of morphology and function in urinary tract obstruction. II. Findings in experimentally induced ureteric stenosis

    International Nuclear Information System (INIS)

    Rohrschneider, W.K.; Becker, K.; Hoffend, J.; Clorius, J.H.; Darge, K.; Kooijman, H.; Troeger, J.

    2000-01-01

    Purpose. To assess the diagnostic value of combined static-dynamic MR urography (MRU) for the functional-morphological evaluation of experimentally induced urinary tract obstruction in the piglet. Materials and methods. In 20 piglets unilateral ureteric stenosis was created operatively. Post-surgery repeated comparative examinations were obtained with MRU, diuretic renal scintigraphy (DRS), excretory urography (EU) and ultrasound (US). MRU was performed as a combination study with a static 3D-IR-TSE sequence and a dynamic 2D-FFE sequence after Gd-DTPA with frusemide administration. Results. MRU allowed complete depiction of the prestenotic urinary tract and of the stenosis in all cases. In 43 comparative studies MRU was superior to EU in 36, EU to MRU in 2. When single kidney function was calculated with both MRU and DRS, results were highly correlated (r = 0.92). When urinary excretion was compared, significant agreement was achieved with concordant findings in 86 % and slightly discordant results in 12 %. Conclusions. Static-dynamic MR urography permits excellent depiction of experimentally induced urinary tract obstruction in piglets and reliable assessment of individual renal function and urinary excretion. Two advantages of the method stand out - it does not require radiation and it permits functional-morphological correlation. (orig.)

  3. Drug-induced MR urography: the effects of furosemide and intravenous saline injection on MR urography of obstructed and non-obstructed urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Ha; Lee, Myung Jun; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    2001-10-01

    To determine the usefulness of MR urography technique for the evaluation of urinary systems in patients with obstructed urinary tract and normal volunteers with non-obstructed urinary tract after intravenous normal saline and diuretic injection. Three normal volunteers and 12 patients with urinary tract obstruction [ureteral calculi (n=8), extraurinary mass (n=1), ureteral tumor invasion (n=3)] underwent MR urography using a 1.0T scanner and a 2D non-breath-hold heavily T2-weighted fast spin-cho sequence. These acquisition were post-processed with a maximum intensity projection (MIP) algorithm. Two acquisitions were performed, the first prior to saline solution infusion following standard MR urography procedures, and the second, within 2-3 minutes of the infusion of 250 ml saline solution followed by 20 mg of Lasix administered intravenously. For this latter, drug-induced MR urography procedures were followed. In healthy volunteer (n=3) and those experiencing partial obstruction (n=4) by a urinary stone, drug-induced MR urography provided better images of the urinary tract than did standard MR urography. In those in whom a urinary stone or tumor had caused complete obstruction (n=8), standard MR urography provided good images, as did drug-induced MR urography. In patients with a partially or non-obstructed urinary tract, drug-induced MR urography provided better anatomic and functional details of the kidney and urinary tract than did standard MR urography. In those experiencing complete obstruction of the urinary tract, however, standard or drug-induced MR urography permitted very adequate evaluation of the tract, and drug-induced MR urography was unnecessary.

  4. Feasibility of MR urography in patients with urinary diversion

    International Nuclear Information System (INIS)

    Battal, Bilal; Kocaoglu, Murat; Ilica, Turan; Akgun, Veysel; Aydur, Emin; Dayanc, Murat

    2011-01-01

    The aims of this study were to determine the diagnostic value of MR urography and to compare the T2- and T1-weighted MR urography techniques in patients with urinary diversion. We retrospectively reviewed 19 MR urograms in 14 patients (13 male and one female, 8–77 years old, mean age: 54.2) with urinary diversion. Magnetic resonance urography examinations were performed with 1.5-T MR scanners. In addition to T2- and T1-weighted MR urography techniques, conventional T1- and T2-weighted axial and coronal sequences were also obtained. Collecting systems were evaluated in five segments (right proximal and distal collecting system, left proximal and distal collecting system and conduit or reservoir). Imaging features of the urinary collecting systems were evaluated with T2- and T1-weighted MR urography images. The clinical, laboratory data and follow-up imaging findings were regarded as standard. A cross table was formed to determine sensitivity, specificity and accuracy of MR urography techniques. T2-weighted MR urography, T1-weighted MR urography and combination of these two techniques could demonstrate 89.01, 87.65 and 93.83% of all collecting system segments, respectively. For the detection of the pathologic urinary segments, sensitivity, specificity and accuracy were 100, 95.29 and 95.6% in T2-weighted MR urography and 100, 93.42 and 93.82% in T1-weighted MR urography, respectively. Sensitivity, specificity and accuracy were 100% in combined T2- and T1-weighted MR urography technique. Magnetic resonance urography is an effective imaging method for the evaluation of the urinary system in patients with urinary diversion. T2-weighted MR urography alone has high sensitivity, specificity and accuracy, does not require intravenous contrast medium and can be obtained in 3–5 min. However, T1-weighted MR urography may provide additional information in some cases.

  5. Multidetector computed tomography has replaced conventional intravenous excretory urography in imaging of the kidneys: A scoping review of multidetector computed tomography findings in renal tuberculosis

    Directory of Open Access Journals (Sweden)

    Ntombizakhona B.A. Mthalane

    2018-02-01

    Full Text Available Background: Tuberculosis (TB is a worldwide infectious disease burden, especially in non-developed countries, with increased morbidity and mortality among human immunodeficiency virus (HIV-infected patients. Extrapulmonary TB is rare and renal TB is one of the commonest manifestations. The end result of renal TB is end-stage renal disease; however, this can be avoided if the diagnosis is made early. The diagnosis of renal TB is challenging because of the non-specific presentation and low sensitivity of clinical tests. Although the sequel of TB infection in the kidney causes varying manifestations depending on the stage of the disease, multidetector computed tomography (MDCT is capable of demonstrating early findings. We performed a 20-year scoping review of MDCT findings in renal TB to promote awareness. Aim: To identify specific MDCT imaging characteristics of renal TB, promote early diagnosis and increase awareness of the typical imaging features. Methods and material: We searched published and unpublished literature from 1997 to 2017 using a combination of search terms on electronic databases. We followed the Joanna Briggs Institute guidelines. Results: A total of 150 articles were identified, of which 145 were found through electronic search engines and 5 were obtained from grey literature. Seventy-nine articles that fulfilled our inclusion criteria were reviewed. These included original research, case reports, literature review, organisational reports and grey literature. Conclusion: Multidetector computed tomography can reproduce images comparable with intravenous excretory urography; together with advantages of being able to better assess the renal parenchyma and surrounding spaces, it is important in suggesting the diagnosis of renal TB and clinicians should consider including MDCT when investigating patients with recurrent urinary tract infection not responding to usual antimicrobial therapy.

  6. Combined static-dynamic MR urography for the simultaneous evaluation of morphology and function in urinary tract obstruction. I. Evaluation of the normal status in an animal model

    International Nuclear Information System (INIS)

    Rohrschneider, W.K.; Hoffend, J.; Becker, K.; Clorius, J.H.; Darge, K.; Kooijman, H.; Troeger, J.

    2000-01-01

    Objective. A new approach, combined static-dynamic MR urography is evaluated to determine its potential utility for the functional-morphological diagnosis of paediatric urinary tract obstruction. In this initial investigation we sought to evaluate the procedure by imaging the urinary tract of piglets. Materials and methods. Twenty-nine healthy piglets were studied with MR urography (MRU), 99 m Tc-MAG3 diuretic renal scintigraphy (DRS), ultrasound (US) and excretory urography (EU). The functional and morphological findings were compared. For MRU we combined a respiration-triggered 3D-IR-TSE sequence and a dynamic 2D-FFE sequence after Gd-DTPA injection. Results. MRU depicted the complete urinary tract with superior image quality compared to EU. Calculation of time-intensity curves from the dynamic sequence permitted determination of single kidney function from parenchymal ROIs and urinary excretion using the whole kidney ROI. MRU and DRS showed significant agreement in the assessment of both single kidney function and urinary excretion. Disturbances of urinary drainage were generally caused by an overfilled bladder. Conclusions. Combined static-dynamic MRU is well suited for the depiction of the complete urinary tract and for the determination of individual kidney function and urinary excretion in the piglet. (orig.)

  7. Intraosseous Urography Compared with Intravenous Urography: An Experimental Study in the Rabbit Model

    OpenAIRE

    SAĞLAM, Mutlu; UĞUREL, Şahin

    2014-01-01

    This study was performed to evaluate the feasibility of bone injection gun assisted intraosseous administration of contrast media as an alternative to the intravenous route for urography. Intravenous urographies were obtained in 6 rabbits. Urographic examinations by the intraosseous route were performed in the same animals 48 h later. After adequate anesthesia, the retroauricular vein was punctured for intravenous injection and a bone injection gun was used for intraosseous injections to the ...

  8. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  9. CT urography in the urinary bladder: To compare excretory phase images using a low noise index and a high noise index with adaptive noise reduction filter

    International Nuclear Information System (INIS)

    Takeyama, Nobuyuki; Hayashi, Takaki; Ohgiya, Yoshimitsu

    2011-01-01

    Background: Although CT urography (CTU) is widely used for the evaluation of the entire urinary tract, the most important drawback is the radiation exposure. Purpose: To evaluate the effect of a noise reduction filter (NRF) using a phantom and to quantitatively and qualitatively compare excretory phase (EP) images using a low noise index (NI) with those using a high NI and postprocessing NRF (pNRF). Material and Methods: Each NI value was defined for a slice thickness of 5 mm, and reconstructed images with a slice thickness of 1.25 mm were assessed. Sixty patients who were at high risk of developing bladder tumors (BT) were divided into two groups according to whether their EP images were obtained using an NI of 9.88 (29 patients; group A) or an NI of 20 and pNRF (31 patients; group B). The CT dose index volume (CTDI vol ) and the contrast-to-noise ratio (CNR) of the bladder with respect to the anterior pelvic fat were compared in both groups. Qualitative assessment of the urinary bladder for image noise, sharpness, streak artifacts, homogeneity, and the conspicuity of polypoid or sessile-shaped BTs with a short-axis diameter greater than 10 mm was performed using a 3-point scale. Results: The phantom study showed noise reduction of approximately 40% and 76% dose reduction between group A and group B. CTDI vol demonstrated a 73% reduction in group B (4.6 ± 1.1 mGy) compared with group A (16.9 ± 3.4 mGy). The CNR value was not significantly different (P = 0.60) between group A (16.1 ± 5.1) and group B (16.6 ± 7.6). Although group A was superior (P < 0.01) to group B with regard to image noise, other qualitative analyses did not show significant differences. Conclusion: EP images using a high NI and pNRF were quantitatively and qualitatively comparable to those using a low NI, except with regard to image noise

  10. MR urography evaluation of obstructive uropathy

    International Nuclear Information System (INIS)

    Grattan-Smith, J.D.; Jones, Richard A.; Little, Stephen B.

    2008-01-01

    Hydronephrosis and the evaluation of obstructive uropathy are the most common indications for MR urography in our practice. Typically our patients fall into one of two groups: infants with antenatal hydronephrosis and older children who present with abdominal pain, hematuria or urinary tract infection. Obstruction in children is usually chronic and partial. Intermittent episodes of increased pressure occur when the urine production exceeds the capacity for drainage. MR urography uses a fluid and diuretic challenge to assess the hydronephrotic kidney. High-quality anatomic images provide a morphologic assessment of the hydronephrotic system. Although it is relatively straightforward to determine if a system is not obstructed on the basis of the renal transit time (RTT), no single parameter is adequate to fully characterize obstruction. By evaluating the changes in signal intensity in the renal parenchyma following contrast administration, the hydronephrotic systems are classified as compensated or decompensated. Delayed RTT and the presence of urine-contrast levels indicate stasis. Calyceal transit time and the difference between the volumetric and the Patlak differential renal function (vDRF-pDRF) are measures of the physiologic changes within the kidney. Additionally, MR urography provides prognostic information by assessing the quality of the renal parenchyma and identifying uropathy preoperatively. MR urography combines both anatomic and functional information in a single test and is capable of providing a comprehensive evaluation of obstructive uropathy that could ultimately help select those patients most likely to benefit from surgical intervention. (orig.)

  11. MR urography evaluation of obstructive uropathy

    Energy Technology Data Exchange (ETDEWEB)

    Grattan-Smith, J.D.; Jones, Richard A. [Emory University School of Medicine, Department of Radiology, Children' s Healthcare of Atlanta, Atlanta, GA (United States); Little, Stephen B. [Children' s Healthcare of Atlanta, Department of Radiology, Atlanta, GA (United States)

    2008-01-15

    Hydronephrosis and the evaluation of obstructive uropathy are the most common indications for MR urography in our practice. Typically our patients fall into one of two groups: infants with antenatal hydronephrosis and older children who present with abdominal pain, hematuria or urinary tract infection. Obstruction in children is usually chronic and partial. Intermittent episodes of increased pressure occur when the urine production exceeds the capacity for drainage. MR urography uses a fluid and diuretic challenge to assess the hydronephrotic kidney. High-quality anatomic images provide a morphologic assessment of the hydronephrotic system. Although it is relatively straightforward to determine if a system is not obstructed on the basis of the renal transit time (RTT), no single parameter is adequate to fully characterize obstruction. By evaluating the changes in signal intensity in the renal parenchyma following contrast administration, the hydronephrotic systems are classified as compensated or decompensated. Delayed RTT and the presence of urine-contrast levels indicate stasis. Calyceal transit time and the difference between the volumetric and the Patlak differential renal function (vDRF-pDRF) are measures of the physiologic changes within the kidney. Additionally, MR urography provides prognostic information by assessing the quality of the renal parenchyma and identifying uropathy preoperatively. MR urography combines both anatomic and functional information in a single test and is capable of providing a comprehensive evaluation of obstructive uropathy that could ultimately help select those patients most likely to benefit from surgical intervention. (orig.)

  12. Evaluation of urogenital fistulas by magnetic resonance urography

    International Nuclear Information System (INIS)

    Mamere, Augusto Elias; Coelho, Rafael Darahem Souza; Cecin, Alexandre Oliveira; Feltrin, Leonir Terezinha; Lucchesi, Fabiano Rubiao; Seabra, Daniel

    2008-01-01

    Objective: Vesicovaginal and ureterovaginal fistulas are unusual complications secondary to pelvic surgery or pelvic diseases. The therapeutic success in these cases depends on an appropriate preoperative evaluation for diagnosis and visualization of the fistulous tract. The present study is aimed at demonstrating the potential of magnetic resonance urography for the diagnosis of vesicovaginal and ureterovaginal fistulas as well as for defining the fistulous tracts. Materials And Methods: Seven female patients clinically diagnosed with vesicovaginal or ureterovaginal fistulas had their medical records, radiological and magnetic resonance images retrospectively reviewed. Magnetic resonance urography included 3D-HASTE sequences with fat saturation. Results: Six patients presented vesicovaginal fistulas and, in one patient, a right-sided ureterovaginal fistula was diagnosed. Magnetic resonance urography allowed the demonstration of the fistulous tract in six (85.7%) of the seven patients evaluated in the present study, without the need of bladder catheterization or contrast injection. Conclusion: This study demonstrates both the potential and applicability of magnetic resonance urography in the evaluation of these types of fistulas. (author)

  13. Artificial hydroureteronephrosis to facilitate MR urography during pregnancy.

    LENUS (Irish Health Repository)

    Connolly, S S

    2012-02-01

    INTRODUCTION: Insertion of a percutaneous nephrostomy (PCN) catheter decompresses the upper urinary tract, thereby removing the hydroureteronephrosis upon which magnetic resonance (MR) urography is dependent for diagnosing the precise level and cause of ureteric obstruction. METHOD: We present the case of a young woman who required PCN insertion during pregnancy. RESULT: Only when unenhanced T2-weighted MR urography was repeated after the creation of an artificial hydronephrosis by an injection of sterile saline via the PCN catheter was the diagnosis of stone in the mid-ureter later made possible. CONCLUSION: This case highlights an easy solution to a limitation with the use of MR urography during pregnancy, when a physiological hydroureteronephrosis has been relieved by the insertion of a PCN catheter.

  14. Role of static fluid MR urography in detecting post urinary diversion complications

    Directory of Open Access Journals (Sweden)

    Amr Farouk Ibrahim Moustafa

    2018-06-01

    Full Text Available Aim of work: The aim of the study was to assess the diagnostic performance of static MR urography in detection of post cystectomy complications & the ability of static fluid MR urography in visualization of urinary tract segments. Material & methods: We prospectively reviewed 21 MR urograms with urinary diversion. The most common surgical procedures included Ileal conduit & Ileocecal neobladder diversion.Magnetic resonance urography examinations were performed with 1.5-T MR scanners. T2 weighted (static fluid MR urography techniques were done, in addition to conventional T1- and T2-weighted axial and coronal sequences. Urinary tract was divided in different parts: pelvicalyceal systems, upper, mid and lower ureteric segments & the reservoir or conduit Imaging features of the urinary collecting systems were evaluated for their visualization and complications detection. Results: T2-weighted MR urography could demonstrate 95% of urinary tract segments & together with conventional MR sequences all urinary tract segments can be visualized. Urinary diversion related complications were encountered included in 15 patients (71.4% & no urological complications were seen in 6 patients (28.6%. Conclusion: Comprehensive T2-weighted MR urography is an effective imaging method for the visualization of the urinary system and detection of early and late postoperative complications in patients with urinary diversion. Keywords: MR urography, Urinary diversion, Cancer bladder

  15. CT urography and hematuria

    DEFF Research Database (Denmark)

    Bretlau, Thomas; Hansen, Rasmus H; Thomsen, Henrik S

    2015-01-01

    BACKGROUND: Computed tomography (CT) urography is now used in the work-up of patients with hematuria. The dose of contrast medium and radiation varies considerably between the different CT protocols. PURPOSE: To study the disease prevalence in a consecutive group of patients with hematuria...

  16. Prediction of vesico-ureteral reflux in children from intravenous urography films

    International Nuclear Information System (INIS)

    Lanning, P.; Seppaenen, U.; Huttunen, N.P.; Uhari, M.

    1979-01-01

    Intravenous urography and voiding urethrocystography were performed on 255 children with urinary tract infection. Eighty-six (34%) of these children has some kind of abnormality of the urinary tract. Vesico-ureteral reflux was observed to 96 ureters (19%) in 69 children (27%). The prediction of vesic-ureteral reflux by two radiologists from urography films only gave 46 (48%) and 51 (53%) false negative results respectively. In cases of clinically important reflux (III to V 0 ), however, the rate of false negative prediction was 0/18 and 1/18 (6%) respectively. The rate for false positive predictions were 45/413 (11%) for both radiologist. In view of the number of pathological findings in this series i.v. urography is recommended as a routine in children undergoing urological work-up after their first urinary tract infection. As the clinically important vesico-ureteral reflux seems to be predictable from urography films alone, voiding urethrocystography seems not to be justified in children with negative i.v. urography, and can be postponed and carried out later if the urinary tract infection recurs. (author)

  17. The value of HASTE MR urography in the diagnosis of the chronic nephrogenic flank pain

    International Nuclear Information System (INIS)

    Werel, D.; Tarasow, E.; Dzienis, W.; Ustymowicz, A.; Orzechowska-Bobkiewicz, A.; Walecki, J.; Darewicz, B.

    2004-01-01

    To asses the usefulness of the projectional HASTE sequence in the diagnosis of chronic flank pain caused by obstructive uropathy in comparison with conventional urography. 28 patients with chronic flank pain and hydronephrosis on ultrasound underwent conventional urography and HASTE sequence of static MR urography. The methods were evaluated for image quality, presence, agree, level and cause of urinary tract dilatation. The image quality of the urinary tract on HASTE was good in 57.1% and satisfactory in 42.9%; in conventional urography - good in 28.6%, satisfactory in 42.8% and poor in 28.6%. HASTE demonstrated hydronephrosis and degree of hydronephrosis in all the cases and conventional urography in 25 (83.3%). HASTE identified correctly the site of obstruction in 29 cases (96.7%), and conventional urography in 21 cases (70%). The sensitivity of HASTE in diagnosis of the intrinsic and extrinsic causes of obstruction was 73.7% and 80%, accuracy 73.3% and that of conventional urography 68.4%, 40% and 56.7%, respectively. HASTE is a valuable method in the diagnostics of chronic obstructive uropathy. It allows to evaluate the degree of hydronephrosis, the level and in many cases the cause of obstruction. When the urinary tract is not visualized in conventional urography, static MR urography is especially useful. (author)

  18. The clinical application of the digital imaging in urography

    International Nuclear Information System (INIS)

    Zhu Yuelong; Xie Sumin; Zhang Li; Li Huayu

    2003-01-01

    Objective: To evaluate the clinical application of the digital imaging in the urography. Methods: In total 112 patients underwent digital urography, including intravenous pyelography (IVP) in 38 cases and retrograde pyelography in 74 cases. Results: the entire urinary tract was better shown on digital imaging, which was accurate in locating the obstruction of urinary tract and helped the qualitative diagnosis. Digital urography was especially valuable in detecting urinary calculus. In 38 cases of IVP, the results were normal in 5 patients, renal stone in 12, ureteral stone in 13, ureteral stenosis in 6 and nephroblastom in 2. In the 74 cases of retrograde pyelography, benign ureteral stenosis was found in 31 patients, ureteral stone in 27, ureteral polyp in 2, urethral stone in 8 and benign urethral stenosis in 6. Conclusion: Digital imaging technique is of big value in the diagnosis of urinary tract lesions

  19. Multi-slice computed tomography urography after diuretic injection in children with urinary tract dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Kosucu, P.; Ahmetoglu, A.; Imamoglu, M.; Cay, A.; Ozdemir, O.; Dinc, H.; Kosucu, M.; Sari, A.; Saruhan, H.; Gumele, H.R. [Farabi Hospital, Trabzon (Turkey). Dept. of Radiology

    2004-02-01

    To evaluate the potential use of multi-slice computed tomography urography (MSCTU) after diuretic injection in children with urinary tract dilatation. MSCTU was performed in 19 patients (11 boys, 8 girls, mean age 5.4 years) with suspicion of urinary tract obstruction and dilatation. Furosemide, 1 mg/kg, was injected 3 min before contrast material administration and followed by a bolus of 30 ml of physiologic saline solution immediately after application of contrast material. Excretory-phase images were obtained through the abdomen and pelvis beginning 10 min after initiation of the injection of contrast material. Maximum intensity projection (MIP) and volume rendering (VR) images were post-processed to obtain urographic views. MSCTU revealed pathology in 16 of 19 patients, while 3 patients had normal findings. Ureteropelvic obstruction was found in 4 patients, obstructive megaureter in 8. Both ureteropelvic obstruction and obstructive megaureter were disclosed in 1 patient, partial ureteral duplication in 1 patient, and both complete ureteral duplication and ureterocele in 2 patients. In all patients, MIP and VR images could satisfactorily show the pathologies of the urinary tract. The estimated effective average doses of MSCTU were higher than IVU. Preliminary results of furosemide-enhanced MSCTU demonstrated consistently dilated urinary tracts, obstruction levels, and underlying pathologies better than US and IVU.

  20. Renal malignancies with normal excretory urograms

    International Nuclear Information System (INIS)

    Kass, D.A.; Hricak, H.; Davidson, A.J.

    1983-01-01

    Four patients with malignant renal masses showed no abnormality of excretory urograms with tomography. Of the four lesions, two were primary renal cell carcinomas, one was a metastatic focus from a contralateral renal cell carcinoma, and one was a metastatic lesion from rectal adenocarcinoma. A normal excretory urogram should not be considered sufficient to exclude a clinically suspected malignant renal mass. In such an instance, diagnostic evaluation should be pursued using a method capable of topographic anatomic display, such as computed tomography or sonography

  1. Clinical application of a triombrin in urology, a new Soviet radiographic contrast agent

    International Nuclear Information System (INIS)

    Perel'man, V.M.

    1980-01-01

    A water-soluble radiographic contrast agent triombrin which is a methylglucosamine sodium salt mixture of diatrizoate was studied. The analysis is based on the observation of 175 patients subjected to 186 tests, mainly excretory urography with the double dose of the contrast agent. The correlation between the quality of the picture obtained and the individual features of the patients has been established. Assessment of urograms obtained with the use of hypaque, urografin, verografin, urotrast and triombrin has revealed results similar to those with triombrin. Allergic reactions and complications have been noted in 23 (14%) of 164 patients after excretory and infusion urography. Satisfactory contrast and a good tolerance of the agent allowed recommending triombrin for wide use in medical practice

  2. Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Mitsuru, E-mail: m2rbimn@gmail.com [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Kawai, Tatsuya; Ito, Masato; Ogawa, Masaki [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Ohashi, Kazuya [Nagoya City University Hospital, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Hara, Masaki; Shibamoto, Yuta [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan)

    2012-11-15

    Purpose: To prospectively evaluate the feasibility of dual-energy (DE) split-bolus CT-urography (CTU) and the quality of virtual non-enhanced images (VNEI) and DE combined nephrographic-excretory phase images (CNEPI), and to estimate radiation dose reduction if true non-enhanced images (TNEI) could be omitted. Patients and methods: Between August and September 2011, 30 consecutive patients with confirmed or suspected urothelial cancer or with hematuria underwent DE CT. Single-energy TNEI and DE CNEPI were obtained. VNEI was reconstructed from CNEPI. Image quality of CNEPI and VNEI was evaluated using a 5-point scale. The attenuation of urine in the bladder on TNEI and VNEI was measured. The CT dose index volume (CTDI (vol)) of the two scans was recorded. Results: The mean image quality score of CNEPI and VNEI was 4.7 and 3.3, respectively. The mean differences in urine attenuation between VNEI and TNEI were 14 {+-} 15 [SD] and -16 {+-} 29 in the anterior and posterior parts of the bladder, respectively. The mean CTDI (vol) for TNEI and CNEPI was 11.8 and 10.9 mGy, respectively. Omission of TNEI could reduce the total radiation dose by 52%. Conclusion: DE split-bolus CTU is technically feasible and can reduce radiation exposure; however, an additional TNEI scan is necessary when the VNEI quality is poor or quantitative evaluation of urine attenuation is required.

  3. Feasibility of MR urography in neonates and infants with anomalies of the upper urinary tract

    International Nuclear Information System (INIS)

    Riccabona, M.; Ruppert-Kohlmayr, A.; Fotter, R.; Simbrunner, J.; Ebner, F.; Ring, E.

    2002-01-01

    The aim of this study was to evaluate the feasibility and diagnostic potential of dynamic MR urography (MRU) in neonates and infants with sonographically detected abnormalities of the upper urinary tract. Thirty infants (age range 5 days to 3 years, mean age 7.9 months; male:female: 22:8) underwent MRU using T2 and contrast-enhanced dynamic T1-weighted sequences. The results were compared with the findings of ultrasound (n=30), intravenous urography (IVU, n=19) and/or scintigraphy (n=25) based on the criteria suggestive of obstructive uropathy. Oral sedation was sufficient to perform MRU with diagnostic quality in 20 of 21 patients younger than 1 year; 9 older patients needed intravenous sedation. Diagnosis of the 66 renal units (58 kidneys, 29 successful examinations) included normal systems (contralateral units), duplex systems, vesico-ureteral reflux, obstructive megaureter, ureteropelvic junction obstruction and accompanying renal parenchymal disease, with complex pathology in 10 patients. Magnetic resonance urography demonstrated anatomy better than IVU, particularly the renal parenchyma, (ectopic) ureters, and poorly functioning dilated systems. Magnetic resonance urography was superior to US in showing ureteral pathology. Tiny cysts in dysplastic kidneys were better seen by US. Gadolinium-enhanced dynamic MRU allowed accurate assessment of obstruction applying IVU criteria. Here MRU matched IVU results, and most of the scintigraphic findings. Magnetic resonance urography can be performed in young infants with diagnostic quality using oral sedation. Magnetic resonance urography correctly depicts anatomy and allows assessment of the urinary tract better than US and IVU, with additional functional information. Magnetic resonance urography thus has the potential to replace IVU for many indications. (orig.)

  4. Uroradiographic manifestations of Burkitt's lymphoma in children

    International Nuclear Information System (INIS)

    Fernbach, S.K.; Glass, R.B.

    1986-01-01

    The radiological studies of 18 children with biopsy proved Burkitt's lymphoma were analyzed retrospectively. Before therapy the genitourinary tract was evaluated in 15 children by excretory urography, sonography, computerized tomography and/or gallium citrate scintigraphy. Genitourinary abnormalities were detected in 9 children. Changes due to tumor included renal or ureteral displacement in 4 children, hydronephrosis in 3 and intraparenchymal masses in 4. Extrinsic compression of the bladder causing no compromise of function was seen in only 2 children. Gonadal involvement occurred in 2 boys and 1 girl. The modality of choice for evaluating the genitourinary tract in patients with Burkitt's lymphoma has been excretory urography. Since ultrasound and computerized tomography provide more direct information about tumor deposits within the kidney and retroperitoneum, either should be performed in this population before initiation of chemotherapy

  5. Renal cell carcinoma in childhood

    International Nuclear Information System (INIS)

    Zanier, J.F.C.; Ramos, C.O.P.; Pereira, A.A.

    1990-01-01

    The authors present five cases of renal cell carcinoma in children, describing its aspects on excretory urography, ultra-sonography and computerized tomography. The clinical, pathological and radiological features are compared with those of the literature. (author)

  6. Evaluation of DMSA scintigraphy and urography in assessing both acute and permanent renal damage in children

    Energy Technology Data Exchange (ETDEWEB)

    Stokland, E.; Jacobsson, B. [Dept. of Pediatric Radiology, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden).; Hellstroem, M. [Dept. of Radiology, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden); Jodal, U. [Dept. of Pediatrics, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden); Sixt, R. [Dept. of Pediatric Clinical Physiology, Sahlgrenska Univ. Hospital, Goeteborg Univ. (Sweden)

    1998-07-01

    Purpose: To evaluate dimercaptosuccinic acid (DMSA) scintigraphy and urography in the detection of renal involvement in children with urinary tract infection (UTI) in order to identify patients with a high risk of developing renal damage. Material and Methods: A total of 157 children (median age 0.4 years, range 5 days to 5.8 years) with first-time symptomatic UTI were examined scintigraphy (with an assessment of renal area involvement) and urography at the time of UTI and 1 year later. All evaluations were made blindly. Results: Of the total 314 kidneys, 80 (25%) were abnormal at initial scintigraphy. Of these 80 kidneys, 44 (55%) had normalized at follow-up. Of the 234 initially normal kidneys, 29 (12%) were abnormal at follow-up. One year after UTI, abnormalities were seen in 59 children at scintigraphy and in 18 children at urography. Renal area involvement was larger and split function abnormalities more common in kidneys that were abnormal at both scintigraphy and urography than in kidneys with only scintigraphic abnormalities. Conclusion: Quantitation of renal area involvement and split renal function at early scintigraphy would seem to be useful in identifying patients at risk of developing renal damage. Urography at 1 year after infection identified mainly those with the most severe scintigraphic abnormalities. The clinical importance of scintigraphic abnormalities that are not confirmed by urography is not known. (orig.)

  7. Evaluation of DMSA scintigraphy and urography in assessing both acute and permanent renal damage in children

    International Nuclear Information System (INIS)

    Stokland, E.; Jacobsson, B.; Jodal, U.; Sixt, R.

    1998-01-01

    Purpose: To evaluate dimercaptosuccinic acid (DMSA) scintigraphy and urography in the detection of renal involvement in children with urinary tract infection (UTI) in order to identify patients with a high risk of developing renal damage. Material and Methods: A total of 157 children (median age 0.4 years, range 5 days to 5.8 years) with first-time symptomatic UTI were examined scintigraphy (with an assessment of renal area involvement) and urography at the time of UTI and 1 year later. All evaluations were made blindly. Results: Of the total 314 kidneys, 80 (25%) were abnormal at initial scintigraphy. Of these 80 kidneys, 44 (55%) had normalized at follow-up. Of the 234 initially normal kidneys, 29 (12%) were abnormal at follow-up. One year after UTI, abnormalities were seen in 59 children at scintigraphy and in 18 children at urography. Renal area involvement was larger and split function abnormalities more common in kidneys that were abnormal at both scintigraphy and urography than in kidneys with only scintigraphic abnormalities. Conclusion: Quantitation of renal area involvement and split renal function at early scintigraphy would seem to be useful in identifying patients at risk of developing renal damage. Urography at 1 year after infection identified mainly those with the most severe scintigraphic abnormalities. The clinical importance of scintigraphic abnormalities that are not confirmed by urography is not known. (orig.)

  8. Imaging of hematuria.

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2012-02-03

    Hematuria may have a number of causes, of which the more common are urinary tract calculi, urinary tract infection, urinary tract neoplasms (including renal cell carcinoma and urothelial tumors), trauma to the urinary tract, and renal parenchymal disease. This article discusses the current status of imaging of patients suspected of having urologic causes of hematuria. The role of all modalities, including plain radiography, intravenous urography or excretory urography, retrograde pyelography, ultrasonography, and multidetector computed tomography (MDCT) in evaluation of these patients is discussed. The article highlights the current status of MDCT urography in imaging of patients with hematuria, and discusses various-often controversial-issues, such as optimal protocol design, accuracy of the technique in imaging of the urothelium, and the significant issue of radiation dose associated with MDCT urography.

  9. Secondary hypertension: Place of imaging techniques

    International Nuclear Information System (INIS)

    Marichez, M.; Jeunemaitre, X.; Despres, E.; Plouin, P.F.; Melki, J.P.; Taleb, A.

    1987-01-01

    To determine and illustrate the place of various imaging techniques in the diagnosis of arterial hypertension, a retrospective study of 4,530 patients examined during the past 2 years at Broussals and Saint Joseph Hospitals in Paris was undertaken. Between 1975 and 1984, only 20% of our patients underwent surgery, but in the past 2 years, 6% of patients with hypertension underwent either surgery or transluminal angioplasty. At our institution, imaging studies performed were Doppler US, excretory urography, CT, MR imaging, scintigraphy, adrenal venography, and arteriography. The authors encountered over 156 cases of renovascular hypertension, 23 Conn adenomas, 13 pheochromocytomas, four adrenal carcinomas, and 46 parenchymatous renal anomalies. This paper presents the modalities and the pitfalls of each imaging technique. The authors also indicate the strategies used in the diagnostic approach and the results the authors obtained

  10. Diuretic urography in the assessment of obstruction of the pelvi-ureteric junction

    International Nuclear Information System (INIS)

    Nilson, A.E.; Aurell, M.; Bratt, C.G.; Nilsson, S.

    1980-01-01

    Twenty adult patients with urographic evidence of unilateral, moderately wide renal pelves were examined by routine and diuretic urography. Planimetry of the corresponding calyx system of the two examinations was performed. An increase in size by more than 20 per cent following osmotic diuresis indicated an obstruction of the pelvi-ureteric junction in kidneys with moderately wide renal pelves. Diuretic urography may be useful to diagnose obstruction as a cause of moderately wide renal pelves and to assess operative results. (Auth.)

  11. MR urography: Anatomical and quantitative information on ...

    African Journals Online (AJOL)

    Background and Aim: Magnetic resonance urography (MRU) is considered to be the next step in uroradiology. This technique combines superb anatomical images and functional information in a single test. In this article, we aim to present the topic of MRU in children and how it has been implemented in Northern Greece so ...

  12. Experiences of using a single post-contrast CT scan of the urinary tract after triphasic contrast injection

    Directory of Open Access Journals (Sweden)

    Phillip Carl Pretorius

    2011-12-01

    Full Text Available I was alerted to an article in Radiology Vol. 255 No. 2 (May 20101 by a colleague. The article, entitled ‘Kidney and urinary tract imaging: Triple-bolus multidetector CT urography as a one-stop shop – Protocol design, opacification, and image quality analysis’, clearly describes the technique, while the quotation below, from the article, summarises the findings: ‘We have shown that triple-bolus multidetector CT urography allowed visualization of renal parenchymal, excretory, and vascular contrast-enhancement phases in a single dose-efficient acquisition and provided sufficient opacification of the UUT, with simultaneous and adequate image quality of renal parenchyma and vascular anatomy.’ The main emphasis on this technique is to reduce the number of unnecessary CT scans when assessing the urinary tract. Our previous protocol for scanning the urinary tract for pathology included four phases: a pre-contrast, corticomedullary, nephrographic and delay excretory phase.

  13. Impact of magnetic resonance urography and ultrasonography on ...

    African Journals Online (AJOL)

    Background: (1) To evaluate the diagnostic value of magnetic resonance urography (MRU) in comparison with ultrasonography (US) to determine the extent of upper urinary tract dilation and (2) to evaluate the impact of MRU on therapy management. Materials and Methods: From January 2005 to December 2010, ...

  14. A Comparative Study of 131I-Hippuran Renogram, 131I-Hippuran Urinary Excretion Test and Intravenous Pyelogram in Obstructive Uropathy due to Cancerous Invasion

    International Nuclear Information System (INIS)

    Park, Kee Bok; Rhee, Chong Heon; Hong, Chang Gi; Park, Soo Seong; Koh, Chang Soon

    1968-01-01

    A comparative study of 131 I-hippuran renogram, 131 I-hippuran excretion test and intravenous pyelogram were performed in 61 cases of gynecological cancer. The following were the results: 1) Among 40 cases of cervix cancer showing normal excretory urography 7 cases (17.5%) were found to have unilateral or bilateral delayed excretory pattern on 131 I-hippuran renogram and on the contrary only 2 cases (5.7%) showed a mild caliectatic change on excretory urography among 35 cases of gynecological cancer showing normal pattern of 131 I-hippuran renogram. 2) In the group showing unilateral of bilateral delayed excretory pattern of 131 I-hippuran renogram there was a reduction of 131 I-hippuran excretion in the first 20 minutes, but there was no significant difference of 131 I-hippuran excretion in 60 minutes compared with that of normal renogram group. 3) In the group showing unilateral non-functioning pattern of 131 I-hippuran renogram in one side and normal pattern in the other side there was found to be no difference in 131 I-hippuran excretion amount compared with that of normal renogram group. 4) It was evident from these experimental study that 131 I-hippuran renogram was considered as a good examination method for the evaluation of obstructive uropathy, and if one side kidney was intact it might compensate for the other diseased kidney so far as to renal excretory function. It was also shown that the more severe the cancerous spread in the pelvic wall the more changes on 131 I-hippuran renogram.

  15. Antigenic analyses of tissues and excretory and secretory products from Strongylus vulgaris.

    Science.gov (United States)

    Wynne, E; Slocombe, J O; Wilkie, B N

    1981-07-01

    Rabbit antisera were prepared against veronal buffered saline extracts of L4 and L5 Strongylus vulgaris, adult S. vulgaris and adult Strongylus equinus retrieved from naturally infected horses. In agar gel diffusion with these antisera, adult S vulgaris and S. equinus each appeared to have at least one unique antigen; larval S. vulgaris appeared to have two species-specific and two stage-specific antigens. There were several common antigens. Excretory and secretory products were collected also from L4 and L5 an maintained over several days in tissue culture fluid. In agar gel diffusion against the above rabbit antisera, a stage-specific antigen was found also in excretory and secretory products. In addition, excretory and secretory products had three antigens in common with adult and larval S. vulgaris, but only one of these was common to adult S. equinus. The excretory and secretory products appear, therefore, to have two species-specific and one stage-specific antigens.

  16. MR urography for the preoperative evaluation of living renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, Jeannette; Kort, Gerard A.P. de; Lo, Rob; Gils, A.P.G. van; Beek, Frederik J.A. [Department of Radiology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Hene, Ronald J. [Department of Nephrology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Lock, Tycho M.T.W. [Department of and Urology, University Hospital Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Burger, Huib [Julius Center for Patient Oriented Research, University of Utrecht, 3584 CX Utrecht (Netherlands)

    2002-08-01

    The purpose of this study was to assess the image quality and diagnostic value of MR urography in detecting abnormalities of the urinary collecting system relevant for the preoperative evaluation of living renal donors. Study subjects were selected from the existing intravenous urography (IVU) reports: 18 consecutive patients with a duplication or another abnormality of the collecting system and 20 consecutive patients with normal anatomy. They underwent a respiratory-triggered 3D T2-weighted fast spin-echo acquisition after oral administration of furosemide, without and with abdominal compression. The MR images were evaluated by two independent blinded observers. The IVU was used as the standard of reference. Image quality of the MR urograms with compression was overall better than those without compression, and the former were regarded as adequate for the evaluation of small filling defects and deformities of the pelvis and calyces in 76-81% of the kidneys and 74-79% of the patients. Both observers correctly diagnosed all 13 kidneys with a partial or complete duplication. The image quality of MR urography was inadequate to evaluate the calyces and pelvis for small filling defects or deformities in approximately 25% of the patients; however, the technique was accurate in the detection of abnormalities of the urinary collecting system relevant for the preoperative evaluation of living renal donors. (orig.)

  17. Gd-DTPA-enhanced T{sub 1}-weighted excretory MR urography after low-dose diuretic injection; T{sub 1}-gewichtete MR-Ausscheidungsurographie mittels Gd-DTPA und vorheriger niedrigdosierter Gabe eines Diuretikums

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Buecker, A.; Adam, G.; Neuerburg, J.; Guenther, R.W. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1997-09-01

    Purpose: Assessment of the morphology of the urinary tract by gadolinium(Gd)-enhanced T{sub 1}-weighted MR-urography (MRU) and precontrast diuretic injection. Methods: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T{sub 1}-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. Results: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. (orig./AJ) [Deutsch] Ziel: Darstellung der Morphologie der ableitenden Harnwege mittels T{sub 1}-gewichteter MR-Urographie (MRU) nach Gabe eines nierengaengigen Gadolinium(Gd)-Chelates und vorheriger Diuretikumapplikation. Methoden: Der Harntrakt von 5 Patienten wurde nach Injektion von Gd-DTPA mit koronaren T{sub 1}-gewichteten 3D-Gradienten-Echo-Sequenzen unterschiedlicher Ortsaufloesung untersucht. Vor der Kontrastmittelgabe wurden jeweils 10 mg Furosemid intravenoes verabreicht. Ergebnisse: Nach initialer Steigerung des Harnflusses durch Furosemidgabe wurden Uebersichtsurogramme mit vollstaendig durchzeichnenden Ureteren bereits 10 min nach Gd-Injektion erzielt. Maximumintensitaetsprojektionen ermoeglichten die Beurteilung des dreidimensionalen Verlaufes der Ureteren ohne Blasenueberlagerung. Eine genauere anatomische Darstellung der Nierenkelche erforderte neben einem guten Fuellungszustand eine moeglichst hohe Sequenzaufloesung, die mit Uebersichtsurogrammen allein nicht zu erreichen war. (orig./AJ)

  18. The value of computed tomography-urography in predicting the ...

    African Journals Online (AJOL)

    Background The natural course of pelviureteric junction (PUJ) obstruction is variable. Of those who require surgical intervention, there is no definite reliable preoperative predictor of the likely postoperative outcome. We evaluated the value of preoperative computed tomography (CT)-urography in predicting the ...

  19. Genito-urinary tuberculosis - experience with 52 urology inpatients

    African Journals Online (AJOL)

    ism. Fifty patients underwent excretory urography and the findings were very varied. Patients were treated priInarily with antituberculosis drugs, but. 58% also required some form. ofsurgery; nephrec- tomy was the commonest operation. Ureteral strictures developed in over 50% of cases with renal involvement. We conclude ...

  20. Urothelial carcinoma in a pyelocaliceal diverticulum discovered by magnetic resonance urography[

    Energy Technology Data Exchange (ETDEWEB)

    Akatsuka, Jun; Suzuki, Yasutomo; Hamasaki, Tsutomu; Kimura, Go; Kondo, Yukihiro, E-mail: s00-001@nms.ac.jp [Departments of Urology, Nippon Medical School, Bunkyo-ku, Tokyo (Japan)

    2014-03-15

    Neither computed tomography (CT) nor intravenous pyelography (IVP) alone can diagnose tumors of renal pelvic diverticula, but magnetic resonance urography (MRU) can obtain accurate preoperative information. (author)

  1. DIAGNOSTICS AND TREATMENT OF EXCRETORY DEFICIENCY OF PANCREAS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    S.V. Bel’mer

    2009-01-01

    Full Text Available Excretory pancreatic insufficiency is relatively frequent pathology in pediatric and therapeutic practice. It can be divided to primary and secondary, inborn and acquired, absolute and relative one. The causes of primary pancreatic insufficiency are agenesia or hypoplasia of pancreas, cystic fibrosis, Shwachman–Diamond syndrome. Secondary excretory pancreatic insufficiency can be caused by resection of pancreas, pancreatitis, pathology of mucous tunic of small intestine, abnormality of antitrypsinactivation with enterokinase deficiency, inactivation of enzymes by acid of duodenal contents in the presence of gastric hyper secretion and others. Excretory pancreatic deficiency has determined clinical signs and can be relatively easily diagnosed by simple laboratory methods: coprogramm and detection of elastase 1 in stool. The ways of its correction are determined by causes of disease, but modern high-active pancreatic enzymes medications must be necessary component of treatment in all cases.Key words: children, pancreatic insufficiency, celiac disease, pancreatic enzymes medications.(Voprosy sovremennoi pediatrii — Current Pediatrics. 2009;8(2:114-118

  2. Urothelial carcinoma in a pyelocaliceal diverticulum discovered by magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Jun Akatsuka

    2014-04-01

    Full Text Available Neither computed tomography (CT nor intravenous pyelography (IVP alone can diagnose tumors of renal pelvic diverticula, but magnetic resonance urography (MRU can obtain accurate preoperative information.

  3. Iohexol compared with metrizoate in urography

    International Nuclear Information System (INIS)

    Levorstad, K.; Kolbenstvedt, A.; Loeyning, E.W.

    1983-01-01

    Urography was performed in 20 patients using the new non-ionic contrast medium iohexol (Omnipaque) and in 22 patients using the conventional ionic medium metrizoate (Isopaque) in a randomized, double blind comparison. Iohexol caused significantly less subjective reactions and less tachycardia than metrizoate. No significant difference between the contrast media was observed regarding the influence on blood pressure, hematologic parameters, or clinical chemical parameters in blood and urine. Urographic films of similar and high quality were obtained with both contrast media. (Auth.)

  4. Circumcaval ureter with synchronous ipsilateral transitional cell ...

    African Journals Online (AJOL)

    We report a case of concomitant transitional cell carcinoma (TCC) in a circumcaval ureter and invasive bladder cancer. The diagnosis was based on the findings of excretory urography (IVU) and contrast-enhanced computed tomography (CT). IVU showed a typical J-shaped deformity in the dilated right proximal ureteric ...

  5. Static fluid magnetic resonance urography in evaluation of ureteral ...

    African Journals Online (AJOL)

    Introduction: Ectopic ureters are often very difficult to diagnose with conventional imaging modalities especially in children. Magnetic resonance urography (MRU) has been recently investigated as a problem-solving tool for the evaluation of various congenital urogenital anomalies with favorable results. Aim of the work: To ...

  6. Comparison of radiography and ultrasonography in the evaluation of renal lesions in the dog

    International Nuclear Information System (INIS)

    Konde, L.J.; Park, R.D.; Wrigley, R.H.; Lebel, J.L.

    1986-01-01

    Survey abdominal radiographs, excretory urograms, and nephrosonograms were obtained from 14 dogs with renal lesions. Renal enlargement was suspected on survey radiographs and confirmed by excretory urography in 13 dogs. Radiographic differentiation between a solid and cystic renal lesion was not possible in 9 dogs. Ultrasonography determined the presence of solid masses in 12 dogs, established the presence of a renal cyst in the opposite kidney in 1 dog, and revealed hydronephrosis in 2 dogs. Ultrasonography appeared to be more sensitive than radiography in differentiating the internal characteristics of renal lesions

  7. A Comparative Study of {sup 131}I-Hippuran Renogram, {sup 131}I-Hippuran Urinary Excretion Test and Intravenous Pyelogram in Obstructive Uropathy due to Cancerous Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kee Bok; Rhee, Chong Heon; Hong, Chang Gi; Park, Soo Seong; Koh, Chang Soon [Radiological Research Institue, Seoul (Korea, Republic of)

    1968-03-15

    A comparative study of {sup 131}I-hippuran renogram, {sup 131}I-hippuran excretion test and intravenous pyelogram were performed in 61 cases of gynecological cancer. The following were the results: 1) Among 40 cases of cervix cancer showing normal excretory urography 7 cases (17.5%) were found to have unilateral or bilateral delayed excretory pattern on {sup 131}I-hippuran renogram and on the contrary only 2 cases (5.7%) showed a mild caliectatic change on excretory urography among 35 cases of gynecological cancer showing normal pattern of {sup 131}I-hippuran renogram. 2) In the group showing unilateral of bilateral delayed excretory pattern of {sup 131}I-hippuran renogram there was a reduction of {sup 131}I-hippuran excretion in the first 20 minutes, but there was no significant difference of {sup 131}I-hippuran excretion in 60 minutes compared with that of normal renogram group. 3) In the group showing unilateral non-functioning pattern of {sup 131}I-hippuran renogram in one side and normal pattern in the other side there was found to be no difference in {sup 131}I-hippuran excretion amount compared with that of normal renogram group. 4) It was evident from these experimental study that {sup 131}I-hippuran renogram was considered as a good examination method for the evaluation of obstructive uropathy, and if one side kidney was intact it might compensate for the other diseased kidney so far as to renal excretory function. It was also shown that the more severe the cancerous spread in the pelvic wall the more changes on {sup 131}I-hippuran renogram.

  8. Contribution of abdoscan using MR cholangio-pancreatography and MR urography

    International Nuclear Information System (INIS)

    Lecesne, R.; Drouillard, J.; Cisse, R.; Schiratti, M.

    1998-01-01

    MR cholangio-pancreatography (MRCP) and MR Urography (MRU) are promising recent imaging modalities. Oral magnetic particles (Abdoscan, Nycomed SA, Oslo, Norway) is an negative contrast agent eliminating signal intensity of the gastro-intestinal tract thus improvising image quality at MRCP and MRU. (author)

  9. MR urography in children. Pt. 2. How to use ImageJ MR urography processing software

    Energy Technology Data Exchange (ETDEWEB)

    Vivier, Pierre-Hugues; Dacher, Jean-Nicolas [University Hospital of Rouen, Department of Radiology, Rouen (France); University of Rouen, LITIS Laboratory EA 4108, School of Medicine and Pharmacy, Rouen (France); Dolores, Michael [University Hospital of Rouen, Department of Radiology, Rouen (France); Taylor, Melissa [Department of Paediatrics, Ambroise Pare Hospital, Boulogne Billancourt (France)

    2010-05-15

    MR urography (MRU) is an emerging technique particularly useful in paediatric uroradiology. The most common indication is the investigation of hydronephrosis. Combined static and dynamic contrast-enhanced MRU (DCE-MRU) provides both morphological and functional information in a single examination. However, specific post-processing must be performed and to our knowledge, dedicated software is not available in conventional workstations. Investigators involved in MRU classically use homemade software that is not freely accessible. For these reasons, we have developed a software program that is freely downloadable on the National Institute of Health (NIH) website. We report and describe in this study the features of this software program. (orig.)

  10. Analysis of the effect of renal excretory system cooling during thermal radiofrequency ablation in an animal model

    Directory of Open Access Journals (Sweden)

    Andre Meireles

    2014-01-01

    Full Text Available Objective: Analysis of renal excretory system integrity and efficacy of radiofrequency ablation with and without irrigation with saline at 2 o C (SF2. Materials and Methods: The median third of sixteen kidneys were submitted to radiofrequency (exposition of 1 cm controlled by intra-surgical ultrasound, with eight minutes cycles and median temperature of 90 o C in eight female pigs. One excretory renal system was cooled with SF2, at a 30ml/min rate, and the other kidney was not. After 14 days of post-operatory, the biggest diameters of the lesions and the radiological aspects of the excretory system were compared by bilateral ascending pyelogram and the animals were sacrificed in order to perform histological analysis. Results: There were no significant differences between the diameters of the kidney lesions whether or not exposed to cooling of the excretory system. Median diameter of the cooled kidneys and not cooled kidneys were respectively (in mm: anteroposterior: 11.46 vs. 12.5 (p = 0.23; longitudinal: 17.94 vs. 18.84 (p = 0.62; depth: 11.38 vs. 12.25 (p = 0.47. There was no lesion of the excretory system or signs of leakage of contrast media or hydronephrosis at ascending pyelogram. Conclusion: Cooling of excretory system during radiofrequency ablation does not significantly alter generated coagulation necrosis or affect the integrity of the excretory system in the studied model.

  11. Role of magnetic resonance urography in diagnosis of duplex renal system: Our initial experience at a tertiary care institute

    Directory of Open Access Journals (Sweden)

    Milind P Joshi

    2009-01-01

    Full Text Available Aim: To determine diagnostic value of magnetic resonance urography in cases of duplex renal system. Method: Twenty cases between five month to nine years with suspected or known duplex renal system were evaluated by ultrasound (USG, micturating cystourethrography (MCU, intravenous urography (IVU and magnetic resonance urography (MRU. The findings of these diagnostic imaging studies were then compared with each other and against the results of final diagnosis established at surgery. Results: Duplex renal system could be identified in two of these cases on USG, was diagnosed in four in IVU and could be diagnosed in all cases with MRU. Conclusion: MRU is superior and far accurate than IVU, MCU and USG in diagnosing duplex renal system.

  12. [Peculiarities of ultrastructure of excretory system in Bothrioplana semperi (Platyhelminthes, Turbellaria)].

    Science.gov (United States)

    Kornakova, E E

    2010-01-01

    Ultrastructural study of morphology of cirtocytes and excretory channels was performed in the free living turbellaria Bothrioplana semperi (Turbellaria, Seriata). It has been shown that cirtocytes of this species are formed by two cells--the terminal and the proximal cells of the channel. The fan is composed of two rod rows. The external row goes out from the terminal cell, the internal one is a derivate of the channel proximal cell. Inside each rod of the external row there runs a bundle of microfilaments; it originates in the cytoplasm of the channel proximal cell distal to bases of the external rods. On the internal rod membranes there are noted small electrondense granules disposed separately or fused in the solid layer continuing into a dense "membrane" connecting rods of the external and internal rows. Rare internal leptotrichiae go out from the cirtocyte cavity bottom. External leptotrichiae are absent. The septate desmosome at the level of the terminal cell is absent, but is present in the channel proximal cell at the level of terminal of cilia. The apical surface of the channel cell carries rare short microvilli. The basement membrane of cells of excretory channels forms deep invaginations almost reaching the apical membrane. Epithelium of excretory channels is deprived of cilia. Ultrastructure of cirtocytes and excretory channels of B. semperi is similar to those in representatives of the suborder Proseriata (Seriata). The significance of ultrastructure of the Proseriata cirtocytes, especially of the order of formation of versh, for construction of phylogeny of Platyhelminthes is discussed.

  13. MR urography in children. Pt. 1. How we do the F0 technique

    Energy Technology Data Exchange (ETDEWEB)

    Vivier, Pierre-Hugues; Dacher, Jean-Nicolas [University Hospital of Rouen, Department of Radiology, Rouen (France); University of Rouen, LITIS Laboratory EA 4108, School of Medicine and Pharmacy, Rouen (France); Dolores, Michael [University Hospital of Rouen, Department of Radiology, Rouen (France); Taylor, Melissa [Ambroise Pare Hospital, Department of Paediatrics, Boulogne Billancourt (France); Elbaz, Frederic; Liard, Agnes [University Hospital of Rouen, Department of Pediatric Surgery, Rouen (France)

    2010-05-15

    MR urography (MRU) has been widely accepted as a substitute to intravenous urography for investigating children with a dilated urinary tract after preliminary assessment by US and voiding cystourethrography. Hydronephrosis is by far the main indication for MRU because upper tract dilatation is a frequent condition in infants and children. Recent advances in technology have allowed MR to go beyond morphology and to assess renal function parameters such as split renal function and drainage. In this article we report our routine practice of the F0 MRU technique. The main advantages of our protocol are no requirement for general anaesthesia, no bladder catheterization, use of low-dose gadolinium-based contrast agent (0.05-0.1 mmol/kg) and total acquisition time of 30 min or less. (orig.)

  14. Virtual endoscopy of the upper urinary tract based on contrast material-enhanced MR urography data sets; Virtuelle Endoskopie des oberen Harntraktes auf der Basis kontrastangehobener MR-Urographie Datensaetze

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Krombach, G.; Staatz, G.; Kilbinger, M.; Adam, G.B.; Guenther, R.W. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1999-06-01

    Purpose: To investigate the feasibility of reconstructing a virtual endoscopy from MR imaging data sets of the upper urinary tract. Method: The data obtained from 28 contrast-enhanced MR urographic examinations (5 normal; 23 pathologic) were post-processed to reconstruct a virtual ureterorenoscopy (VURS) using a threshold image segmentation. The visualization of the upper urinary tract was based on the acquisition of T{sub 1}-weighted 3D gradient-echo sequences after intravenous administration of gadolinium-DTPA and a prior injection of low-dose furosemide. Results: The employed MR urography technique created in all 28 cases a complete and strong contrast enhancement of the urinary tract. These 3D sequence data allowed the reconstruction of a VURS, even when the collecting system was not dilated. The best accuracy was provided by the MR urography sequences with the smallest voxel size. Moreover, the data acquisition based on a breath-hold technique has proved superior to that using a respiratory gating. Inside the renal pelvis, all calices could be assessed by turning the virtual endoscope in the appropriate direction. The visualization of the ureteral orifices in the bladder was also possible. All filling defects that were diagnosed by MR urography could be evaluated from the endoluminal view using the VURS. The exact characterization of the lesions based only on the assessment of the surface structure was difficult. Conclusion: A virtual endoscopy of the upper urinary tract can be successfully reconstructed using the data sets of high-resolution 3D MR urography sequences. (orig.) [Deutsch] Ziel: Untersuchungen zur Anwendung der virtuellen Endoskopie auf MR-tomographische Datensaetze des oberen Harntraktes. Methoden: Die Daten von 28 kontrastangehobenen MR-Urographien (5 normal; 23 pathologisch) wurden zur Erstellung einer virtuellen Ureterorenoskopie (VURS) mittels Schwellenwert-Bildsegmentierung nachverarbeitet. Als Grundlage fuer die Darstellung des Harntraktes

  15. Congenital pyeloureteral junction stenosis -postoperative follow-up with MDCT urography

    International Nuclear Information System (INIS)

    Al-Amin, M.

    2012-01-01

    Full text: 30-year-old male patient with asymptomatic congenital hydronephrosis of the left kidney detected on routine ultrasound investigation in relation to haematemesis 7 years ago. It is established a pyeloureteral junction stenosis and has made a resection of the stenotic part of the segment with a further plastic by Anderson - Haynes - Kuester. The histological analysis of resected area found expressed muscle layer and chronic inflammatory infiltrates as same as the in miofibroepithel disembriogenesis. After that, there was a recidive of the hydronephrosis and a further replastic and endopyeloplastic surgery performed in Germany in 2008. Two years after that with multislice computed tomography and computed tomography urography showing recurrence of the disease. Hydronephrosis is nonobstructive, asymptomatic, with no gallstones visualized along the left ureter. There is a delayed drainage function of the left kidney, which does not separate contrast medium in the 60th minute of computed tomography urography. The diagnosis of the condition is a nonobstructive hydronephrosis recidive of the left kidney. There are no aberrant renal arteries or renal arteries stenosis on postprocessing imaging

  16. A designated centre for people with disabilities operated by Praxis Care, Co. Dublin

    LENUS (Irish Health Repository)

    Moloney, Fiachra

    2014-01-01

    This paper discusses the current status of imaging in the investigation of patients with haematuria. The physician must rationalize imaging so that serious causes such as malignancy are promptly diagnosed while at the same time not exposing patients to unnecessary investigations. There is currently no universal agreement about the optimal imaging work up of haematuria. The choice of modality to image the urinary tract will depend on individual patient factors such as age, the presence of risk factors for malignancy, renal function, a history of calculus disease and pregnancy, and other factors, such as local policy and practice, cost effectiveness and availability of resources. The role of all modalities, including conventional radiography, intravenous urography\\/excretory urography, ultrasonography, retrograde pyelography, multidetector computed tomography urography (MDCTU), and magnetic resonance urography, is discussed. This paper highlights the pivotal role of MDCTU in the imaging of the patient with haematuria and discusses issues specific to this modality including protocol design, imaging of the urothelium, and radiation dose. Examination protocols should be tailored to the patient while all the while optimizing radiation dose.

  17. Haematuria: an imaging guide.

    LENUS (Irish Health Repository)

    Moloney, Fiachra

    2014-01-01

    This paper discusses the current status of imaging in the investigation of patients with haematuria. The physician must rationalize imaging so that serious causes such as malignancy are promptly diagnosed while at the same time not exposing patients to unnecessary investigations. There is currently no universal agreement about the optimal imaging work up of haematuria. The choice of modality to image the urinary tract will depend on individual patient factors such as age, the presence of risk factors for malignancy, renal function, a history of calculus disease and pregnancy, and other factors, such as local policy and practice, cost effectiveness and availability of resources. The role of all modalities, including conventional radiography, intravenous urography\\/excretory urography, ultrasonography, retrograde pyelography, multidetector computed tomography urography (MDCTU), and magnetic resonance urography, is discussed. This paper highlights the pivotal role of MDCTU in the imaging of the patient with haematuria and discusses issues specific to this modality including protocol design, imaging of the urothelium, and radiation dose. Examination protocols should be tailored to the patient while all the while optimizing radiation dose.

  18. Bilateral congenital midureteric strictures associated with multicystic dysplastic kidney and hydronephrosis: evaluation with MR urography

    Energy Technology Data Exchange (ETDEWEB)

    Grattan-Smith, J.D.; Little, Stephen [Children' s Healthcare of Atlanta, Department of Radiology, Atlanta, GA (United States); Jones, Richard A. [Children' s Healthcare of Atlanta, Department of Radiology, Atlanta, GA (United States); Emory University School of Medicine, Department of Radiology, Atlanta, GA (United States); Kirsch, Andrew J. [Emory University School of Medicine, Department of Pediatric Urology, Atlanta, GA (United States)

    2011-01-15

    We report a case of bilateral congenital midureteric strictures diagnosed using MR urography. The severity of obstruction differed in the two ureters, resulting in a multicystic dysplastic kidney (MCDK) with an atretic ureter on one side and hydronephrosis that worsened over time due to progressive stenosis on the other. Although midureteric strictures are usually misdiagnosed as ureteropelvic junction (UPJ) or ureterovesical junction (UVJ) obstruction on conventional imaging, MR urography was able to clearly demonstrate both the anatomical and functional abnormalities. Additionally, because of the excellent anatomical resolution, similarities in the underlying pathological lesions could be contrasted with the severity of the pathophysiological impact upon each kidney. (orig.)

  19. Nonvisualized ('Phantom') renal calyx: Causes and radiological approach to diagnosis

    International Nuclear Information System (INIS)

    Brennan, R.E.; Pollack, H.M.

    1979-01-01

    A calyx which fails completely to opacify on excretory urography (phantom calyx) is often the harbinger of serious underlying renal disease. Causes of a phantom calyx include tuberculosis, tumor, calculus, ischemia, trauma, and congenital anomaly. The pathololgic basis for the radiographic findings in each of these entities is described and an overall approach to diagnosis is set forth. (orig.) [de

  20. 1-3-7 minute intravenous urography

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Yoon, Sei Chul; Lee, Myung Hee

    1980-01-01

    Intravenous urography (IVU) as it is used widely today was probably started in early 1950's after the introduction of triiodobenzoic acid compounds as contrast media. This long cherished traditional method consists of taking radiograms at 5, 15 and 25 minutes after the injection of contrast medium. There are a few modifications of this standard urographic examination such as five minute IVU (Woodruff, 1959), minute-sequence pyelogram (Maxwell et al., 1964), drip infusion pyelography (Schencker, 1964) and nephrotomography (Evans et al., 1955). The present study has been undertaken to test if the conventional standard IVU can be more rapidly performed without losing essential informational contents of urograms. In this new clinical trial, urograms were taken at the end of 1, 3 and 7 minutes instead of 5, 15 and 25 minutes after the intravenous injection of contrast medium. We injected 40 ml of meglumine diatrizoate solution within 30 seconds using an 18G iv needle. (The amount of injected contrast medium has been reduced recently to ordinary single dose of 20 ml for subjects weighing less than 8 kg). Upon viewing the 7 minute film in front of an automatic processor, the examination was terminated after obtaining an upright view unless any further radiogram was indicated. As shown in Tables and Figures, our new 1-3-7 minute method has been proven to provide us with as much essential and useful information as conventional 5-15-25 minute urography. Thus, we were able to finish one examination within 10 minutes without losing any necessary diagnostic information. In some of patients with obstructive uropathy such as stone the examination was extended as long as it was desired. Side reactions were occasional nausea, flushing and rare mild vomiting which never prevented the examination

  1. Comparison of CT urography and intravenous urography in patients with hematuria

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Guen Young; Kang, Byung Chul; Hwang, Ji Young [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2006-12-15

    We wanted to compare CT urography (CTU) with using multi-detector row CT (MDCT) and intravenous urography (IVU) for diagnosing the causes of hematuria. From January 2003 to March 2004, IVU and CTU were obtained in 48 patients. We evaluated the causes of hematuria in 34 of 48 patients. The IVU images were obtained by the conventional method. The CTU images were routinely obtained before intravenous contrast injection, and at 2 and 5 minutes after intravenous contrast injection. In case of delayed excretion of contrast by the kidneys, the delayed CT scans were obtained at 120 minutes after contrast injection. All the CT images, including the axial and 3D coronal reformatted CTUs with using software as well as conventional IVU images, were reviewed by two radiologists working in consensus. We decided if urinary stone existed or not and we looked for the indirect signs such as hydronephrosis or delayed excretion, etc. We also observed if it was possible to determine the mass, ureteral stricture and enhancement of the ureteral wall, etc. We calculated sensitivity, specificity, positive predictive value and negative predictive value for each modality to diagnose urinary stone. We compared the detection rate according to the phases of CTU. We confirmed the presence of urinary tract stones in 27 of 34 patients who had undergone both IVU and CTU. We diagnosed ureteritis in 1, transitional cell carcinoma in 5 and acute pyelonephritis in 1 of the remaining 7 patients. The urinary stones were detected in fifteen patients on both IVU and CTU (15/27, 55.6%). We detected the urinary stones on CTU, but not IVU, in twelve patients (12/27, 44.5%). The sensitivity to detect the urinary stones was 100% (27/27) on CTU and 55.6% (12/27) on IVU respectively. The specificity was 100% (7/7) on IVU and CTU, respectively. The positive predictive value was 100% (15/15) on IVU and 100% (27/27) on CTU, respectively. The negative predictive value was 36.8% (7/19) on IVU and 100% (7/7) on CTU

  2. Evaluation of UPJ obstruction before and after pyeloplasty using MR urography

    International Nuclear Information System (INIS)

    Little, Stephen B.; Jones, Richard A.; Grattan-Smith, J.D.

    2008-01-01

    This article builds on the previous article in this symposium and shows how MR urography contributes to the postoperative evaluation of children with UPJ obstruction. By analyzing the postoperative results, we derived new insights into their preoperative evaluation. With MR urography we combine simultaneous physiological and anatomic evaluation that enables us to identify changes in renal pathophysiology that occur in association with impaired drainage and obstruction. We studied 35 children before and after pyeloplasty. The pyeloplasty was considered successful in 30 and unsuccessful in 5. Both anatomic and functional criteria were used. The anatomic parameters included the degree of hydronephrosis, the appearance of the renal parenchyma, the quality of the nephrogram and the presence of crossing vessels. The functional criteria included the renal transit time, the calyceal transit time, the volumetric differential function, the Patlak differential function, the difference between the volumetric and Patlak differential function and the Patlak number per milliliter of renal tissue. No single parameter was sufficient to fully characterize UPJ obstruction, but by synthesizing all the information we were able to subdivide UPJ obstruction into compensated, decompensated and uropathic kidneys. Decompensated systems had the most significant improvement following successful pyeloplasty. Compensated systems showed little improvement in renal function, and uropathic kidneys were associated with a poor prognosis. It is clear that not all UPJ obstructions are the same, and it seems logical that treatment should be individually tailored rather than using a standard approach for all cases. Because MR urography can identify pathophysiological differences in children with UPJ obstruction that are occult to renal scintigraphy, it has an important potential role in identifying those who will benefit most from pyeloplasty and those who are probably best observed. (orig.)

  3. Evaluation of UPJ obstruction before and after pyeloplasty using MR urography

    Energy Technology Data Exchange (ETDEWEB)

    Little, Stephen B. [Children' s Healthcare of Atlanta, Department of Radiology, Atlanta, GA (United States); Jones, Richard A. [Emory University School of Medicine, Children' s Healthcare of Atlanta, Department of Radiology, Atlanta, GA (United States); Grattan-Smith, J.D. [Children' s Healthcare of Atlanta, Department of Radiology, Atlanta, GA (United States); Emory University School of Medicine, Children' s Healthcare of Atlanta, Department of Radiology, Atlanta, GA (United States)

    2008-01-15

    This article builds on the previous article in this symposium and shows how MR urography contributes to the postoperative evaluation of children with UPJ obstruction. By analyzing the postoperative results, we derived new insights into their preoperative evaluation. With MR urography we combine simultaneous physiological and anatomic evaluation that enables us to identify changes in renal pathophysiology that occur in association with impaired drainage and obstruction. We studied 35 children before and after pyeloplasty. The pyeloplasty was considered successful in 30 and unsuccessful in 5. Both anatomic and functional criteria were used. The anatomic parameters included the degree of hydronephrosis, the appearance of the renal parenchyma, the quality of the nephrogram and the presence of crossing vessels. The functional criteria included the renal transit time, the calyceal transit time, the volumetric differential function, the Patlak differential function, the difference between the volumetric and Patlak differential function and the Patlak number per milliliter of renal tissue. No single parameter was sufficient to fully characterize UPJ obstruction, but by synthesizing all the information we were able to subdivide UPJ obstruction into compensated, decompensated and uropathic kidneys. Decompensated systems had the most significant improvement following successful pyeloplasty. Compensated systems showed little improvement in renal function, and uropathic kidneys were associated with a poor prognosis. It is clear that not all UPJ obstructions are the same, and it seems logical that treatment should be individually tailored rather than using a standard approach for all cases. Because MR urography can identify pathophysiological differences in children with UPJ obstruction that are occult to renal scintigraphy, it has an important potential role in identifying those who will benefit most from pyeloplasty and those who are probably best observed. (orig.)

  4. Imaging of a supernumerary kidney

    International Nuclear Information System (INIS)

    Koureas, A.P.; Panourgias, E.C.; Gouliamos, A.D.; Trakadas, S.J.; Vlahos, L.J.

    2000-01-01

    A 33-year-old female patient was investigated for a right lower quadrant pain. The investigation, which included an excretory urography and a computed tomography examination, revealed a normal kidney on the right side and another two normal sized, complete kidneys on the left side, which appeared to have a small parenchymal bridge. The patient was treated surgically for a cyst of the right ovary. (orig.)

  5. Imaging of a supernumerary kidney

    Energy Technology Data Exchange (ETDEWEB)

    Koureas, A.P.; Panourgias, E.C.; Gouliamos, A.D.; Trakadas, S.J.; Vlahos, L.J. [Dept. of Radiology, Areteion Hospital, Athens (Greece)

    2000-11-01

    A 33-year-old female patient was investigated for a right lower quadrant pain. The investigation, which included an excretory urography and a computed tomography examination, revealed a normal kidney on the right side and another two normal sized, complete kidneys on the left side, which appeared to have a small parenchymal bridge. The patient was treated surgically for a cyst of the right ovary. (orig.)

  6. Magnetic resonance urography in duplex kidney with ectopic ureteral insertion

    Directory of Open Access Journals (Sweden)

    Conjeevaram Rajendrarao Thambidorai

    2011-01-01

    Full Text Available This is a report on the use of magnetic resonance urography (MRU in a 6-year-old girl who presented with urinary incontinence. She had a left duplex kidney with poorly functioning upper moiety and ectopic insertion of the dilated upper pole ureter. MRU has been shown to be superior to conventional imaging techniques in delineating poorly functioning moieties of duplex kidneys and ectopic ureters.

  7. Magnetic resonance urography: application in urinary tract obstruction

    International Nuclear Information System (INIS)

    Martin, J.; Malet, A.; Rue, M.; Villajos, M.; Martin, C.; Garcia, D.; Prats, J.

    1999-01-01

    To compare magnetic resonance urography (MRU) and conventional intravenous urography (IVU) in the assessment of the upper urinary tract in patients with obstructive uropathy. Twenty-three patients suspected of having urinary tract obstruction were examined by IVU and MRU, MRU imaging was performed with a 1.0 Tesla multicoil unit. The images were obtained with two MR sequences: a) half-Fourier single shot turbo spin echo (HASTE), and b) highly T2-weighted turbo spin echo (TSE) based on fast acquisition with the relaxation and enhancement (RARE) method. The images were examined independently by four radiologists. Two radiologists reviewed the IVU images by consensus and two reviewed the MRU images by consensus. The incidencences of dilatation and of stricture were calculated and the McNemar test was used to compare the two techniques. The mean duration of MRU was 11 minutes (range: 7 to 25 minutes), while the mean duration of IVU was 363 minutes (range: 45 to 2,160 minutes). IVU took more than 150 minutes to complete in over 50% of the patients. Twenty.one patients presented dilatation of the pyelocaliceal system. MRU disclosed the urinary tract dilatation in all 21 cases, while IVU detected it in 15 (65%: p=0.03). The causes of obstruction were neoplasm (n=9), calculi (n=6) and extrinsic stricture (n=6). MRU is much more reliable and rapid in the detection of dilatation and the site of obstruction in patients with obstructive uropathy, and could be used as an alternative to IVU in certain cases. (Author) 13 refs

  8. Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography.

    Directory of Open Access Journals (Sweden)

    Mazen Sudah

    Full Text Available To prospectively compare the diagnostic performance and the visualization of the upper urinary tract (UUT using a comprehensive 3.0T- magnetic resonance urography (MRU protocol versus triple-phase computed tomography urography (CTU.During the study period (January-2014 through December-2015, all consecutive patients in our tertiary university hospital scheduled by a urologist for CTU to exclude UUT malignancy were invited to participate. Diagnostic performance and visualization scores of 3.0T-MRU were compared to CTU using Wilcoxon matched-pairs test.Twenty patients (39 UUT excreting units were evaluated. 3.0T-MRU and CTU achieved equal diagnostic performances. The benign etiology of seven UUT obstructions was clarified equally with both methods. Another two urinary tract malignant tumors and one benign extraurinary tumor were detected and confirmed. Diagnostic visualization was slightly better in the intrarenal cavity areas with CTU but worsened towards distal ureter. MRU showed consistently slightly better visualization of the ureter. In the comparison, full 100% visualizations were detected in all areas in 93.6% (with 3.0T-MRU and 87.2% (with CTU and >75% visualization in 100% (3.0T-MRU and 93.6% (CTU. Mean CTU effective radiation dose was 9.2 mSv.Comprehensive 3.0T-MRU is an accurate imaging modality achieving comparable performance with CTU; since it does not entail exposure to radiation, it has the potential to become the primary investigation technique in selected patients.ClinicalTrials.gov NCT02606513.

  9. Accuracy of repeated kidney size estimation by ultrasonography and urography in children

    International Nuclear Information System (INIS)

    Hederstroem, E.; Forsberg, L.

    1985-01-01

    The accuracy of repeated sonographic and urographic kidney length measurements in kidney size evaluation was investigated in 80 children 0 to 14 years of age, mean age 4.5 years. At sonography 250 kidney lengths were compared. A difference of 0 to 1.0 cm in repeated length measurement was considered to be good accuracy and 94 per cent of right and 96 per cent of left kidney length were found within this interval-a better result than for urography with 76 per cent of repeated right kidney and 79 per cent of kidney lengths within the same interval (94 lengths). Both methods display a variation of kidney lengths which may lead to under- and overestimation of kidney size and growth. The investigation thus indicates good accuracy for repeated sonographic kidney size assessment which should be repeated often enough to estabilish a growth chart displaying the trend rather than rely too much on single measurements. Sonography can be highly recommended as a convenient and harmless alternative to urography. (orig.)

  10. Modern diagnostic assessment of the upper urinary tract using multislice CT urography; Moderne Diagnostik des oberen Harntraktes mittels Mehrschicht-CT-Urographie

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Adam, G.; Nolte-Ernsting, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-11-15

    The advent of Multislice Computed Tomography (MSCT) has made evaluation of the entire urinary tract with high-resolution sections during a single breath-hold a reality. Acquisition of multiple thin overlapping slices provides excellent two-dimensional (2D) and three-dimensional (3D) reformations of the urinary tract. The concept of 'Multislice CT Urography (MSCTU)' has emerged from this technical improvement. As a result, a wide range of pathologies inside and outside the urinary tract can be identified. During the last several years, MSCTU has challenged intravenous urography (IVU) in the evaluation of urinary tract abnormalities. Compared with IVU, MSCT(U) is more sensitive and specific in the detection and characterization of a variety of urinary tract disorders, including renal masses and urolithiasis. The main advantage of IVU has been its ability to offer excellent delineation of kidney basin cup system and ureteral anatomy and to depict subtle uroepithelial abnormalities. MSCTU has already shown promising results for overcoming this challenge. Optimal opacification and distension appear to be an essential requirement for a thorough evaluation of the collecting system. Dedicated preparation strategies have been developed to meet these technical difficulties. The biggest disadvantage of MSCTU is the significant radiation exposure. For broad routine clinical application, there is still a need for dose reduction protocols despite the ongoing technical developments in MSCTU. In this article, we outline the different concepts of technical processing for MSCTU and summarize the current role of MSCTU in the evaluation of the upper urinary tract. (orig.)

  11. Roentgenological criteria od assessment of stages of hydronephrosis in children

    International Nuclear Information System (INIS)

    Pavlova, M.K.

    1988-01-01

    A new parenchymatous index was proposed in order to raise the resolving power of excretory urography, and 3 stages of hydronephrosis were defined on the basis of quantitative indices. X-ray criteria were defined to prevent surgery in a group of children with the initial stage of disease. A group of patients with the terminal stage of hydronephrosis was subdivided into 2 groups: 1) sparing operation, 2) nephrectomy

  12. Contrast-induced nephropathy following intravenous urography with Iopromid

    International Nuclear Information System (INIS)

    Krysteva, R.; Andreev, E.; Kirojcheva, M.; Kundurdzhiev, A.; Kiperova, B.

    1997-01-01

    In retrospective studies the incidence of contrast-induced nephropathy is less than 1 per cent, while in prospective ones it may reach up to 10 per cent. Thirty-nine patients (9 men and 30 women at mean age 46.6 ± 16.5 years, range 15 - 75) undergo prospective study by iv urography with Iopramid (Ultravist 370) administered at mean dose 0.9 ± 0.1 ml/kg b.w. The patients are distributed in 3 groups: group I - with normal renal function free of diabetes mellitus (33 cases), group II - with normal renal function and diabetes mellitus, group III - with renal failure free of diabetes mellitus (plasma creatinine concentration (Pcr) > 140 μmol/l). Pcr is evaluated prior to (baseline) and 48 hours after urography. Dehydration is precluded and none of the patients is given nephrotoxic drugs. In group I Pcr shows a more than 25 per cent increase in 4 patients, but remains below 140 μmol/l. In 2 patients of the same group Pcr levels exceed the reference values: from 51 to 205, and from 105 to 196 μmol/l in two women aged 70 and 74 years, respectively. Renal function impairment is reversible, with Pcr returning to normal within a week. In groups II and III no changes in Pcr level are noted. A slight elevation of serum creatinine pointing to contrast-induced nephrotoxicity is documented in 4 patients with previously normal renal function. A reversible renal failure is observed in two instances. The obtained results demonstrate an incidence rate of contrast-induced nephropathy amounting to 15.4 per cent, or in 6/39 patients (author)

  13. Virtual cystoscopy, computed tomography urography and optical cystoscopy for the detection and follow-up for bladder cancer.

    Science.gov (United States)

    Ibáñez Muñoz, D; Quintana Martínez, I; Fernández Militino, A; Sánchez Zalabardo, D; Sarria Octavio de Toledo, L; Cozcolluela Cabrejas, R

    To evaluate the utility of virtual cystoscopy (VC) performed with CT urography in patients being studied under gross hematuria or patients being followed-up after a previous bladder cancer and compare the results with those obtained with gold standard technique (optical cystoscopy). Retrospective study of 117 patients who were referred for VC by the Urology Department between May 2014 and May 2015. Those patients presented with gross hematuria or they were previously treated patients from bladder cancer being followed up. These patients were evaluated with MDCT and virtual cystoscopy after distending the bladder with air. The results were compared with those obtained with optical cystoscopy which was performed no more than a week after. The global sensitivity and specificity of VC were 81,8 and 92,1%. Aditional findings detected in CT urography were an aortic dissection, urinary lithiasis and colonic metastasis. VC seems an useful technique in the diagnosis and follow-up for bladder cancer with a good correlation with OC. The main limitations are the impossibility of biopsy during the procedure and the detection of erythematous lesions. Collateral findings can be detected performed with CT urography although the high radiation exposure does not recommend their combined use. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Intravenous urography in children and youth

    International Nuclear Information System (INIS)

    Pedersen, H.K.; Gudmundsen, T.E.; Oestensen, H.; Pape, J.F.

    1987-01-01

    This report derives from Tromsoe in northern Norway. In a retrospective study of the indications for intravenous urography (IU) and the findings at IU in 740 patients (451 girls and 289 boys) aged 0-19 years, we found that urinary tract infections accounted for 69.4% of the IU in females and 30.1% of the IU in males, most often seen in the youngest patients. The pathological findings most frequently seen were anomalies (17 females and 10 males) and urinary tract obstruction (3 females and 15 males). The present study indicates the following: first, that the yield of IU in the primary investigation of children and youth suffering from enuresis and non-specific abdominal disturbancies is small; and second, that the use of IU in children and youth with urinary tract infection and haematuria should be questioned and reconsidered. (orig.)

  15. Hidronefrosis prenatal en doble sistema excretor Prenatal hydronephrosis in double excretory system

    Directory of Open Access Journals (Sweden)

    Sandalio Durán Álvarez

    2007-12-01

    hydronephrosis were studied. The maternofetal ultrasound showed a double excretory system. To this end, all the newborns and infants with prenatally detected hydronephrosis and double excretory system diagnosed before or after birth were followed up by evolutive renal ultrasonography, micturition urethrocystography, static or dynamic scintigraphy and, in some cases, by excretory urogram. Double excretory system was found in 7 of the 182 patients (3.8 % with abnormalities of the urinary tract diagnosed before birth. Diagnosis was prenatal in just one of the fetuses (31 weeks of pregnancy. Hydronephrotic dilatation was mild in two fetuses and severe in five. Hydronephrosis had different causes. Upper polar nephrectomy was performed in those cases of ureteral ectopy and obstructed upper ureter, reimplantation in one ureterocele, whereas in another it was confirmed the spontaneous rupture by endoscopy. The rest of the patients were symptomatically treated. The hydronephrosis detected before birth by maternofetal ultrasonography may be associated with a double excretory system. Hydronephrotic dilatation associated with a double excretory system may have different causes, and it is necessary to study carefully and systematically these children and to treat them adequately, since each of them may need a different conduct.

  16. Study of Pelvicaliceal Anatomy by Helical Computerized Tomography

    International Nuclear Information System (INIS)

    Al-Qahtani, Fahd N.; Ali, Gaber A.; Kamal, Baher A.; Taha, Saud A.

    2003-01-01

    To evaluate the role of 3-dimensional images produced by computerized tomography (CT), using intravenous contrast, to study pelvicaliceal anatomy.This might be of help in endourological procedure. The study was conducted in the King Fahd Hospital of the University, King Faisal University. Dammam,Kingdom of Saudi Arabia. The study took place from July 2002 through to October 2002 .Helical CT was carried for patients who were investigated using excretory urography for any reason. A CT was carried out to the kidneys only within 10 minutes ( between 5 and 15 minute films of excretory urography).Images were reprocessed by 3-dimension construction after subtracting all structures except for the palvicaliceal system. Thity-six normal kidneys were studied. The upper pole was drained by a single caliceal infundibulum in all 36(100%) kidneys.the middle segement of the kidney was drained by 2 infundibula in 32 (89%) kidneys. Four (11%) kidneys have no middle caliceal infudibula. The lower pole was drained by 2 caliceal infundibula in 23 (64%) and a single infundibulum in 13 (36%) kidneys. The minor calices draining each renal segment were seen clearly. Three-dimensional images derived by helical CT are feasible for evaluating the anatomy of palvicaliceal system,and, can be of help in endourological procedures. (author)/

  17. Indications and new diagnostic techniques in micturating cystourethrographic studies

    International Nuclear Information System (INIS)

    Schuster, W.; Bruenger, J.

    1978-01-01

    Urological radiographic procedures on children are of great importance. The frequency of examinations is comparable to the number of Gl tract studies. In diagnosing chronically recurrent urinary tract infections, micturating cystourethrography is a valuable addition to excretory urography. Indications and performance of micturating cystourethrography at juvenile age are described. All measures reducing radiation exposure must be taken into consideration. New technological devices grant improved diagnostic information with a minimal radiation exposure for patients. (orig.) [de

  18. MR urography: the future gold standard in paediatric urogenital imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Borthne, A.; Nordshus, T.; Reiseter, T. [Department of Paediatric Radiology, Ullevaal University Hospital, Oslo (Norway); Geitung, J.T. [Department of General Radiology, Ullevaal University Hospital, Oslo (Norway); Gjesdal, K.I. [Department of Medical Physics and Techniques, Ullevaal University Hospital, Oslo (Norway); Babovic, A. [Department of Nuclear Medicine, Ullevaal University Hospital, Oslo (Norway); Bjerre, A. [Department of Paediatrics, Ullevaal University Hospital, Oslo (Norway); Loe, B. [Department of Paediatric Surgery, Ullevaal University Hospital, Oslo (Norway)

    1999-09-01

    Background. Examination of the paediatric urogenital tract is traditionally performed using methods that utilise ionising radiation, such as intravenous urography (IVU), computerised tomography (CT), voiding cystourethrography (VCU), and scintigraphy, in addition to ultrasound (US). Objective. To determine the potential and effectiveness of MR urography (MRU) in infants and children. Materials and methods. 44 MRU examinations were prospectively performed in 39 patients (21 infants, mean age 3.5 months, and 18 children, mean age 6 years 2 months) with known or suspected pathology of the urinary tract. Non-enhanced, fast spin-echo sequences (TSE) were performed in all patients. In 70 % of the patients a contrast-enhanced, fast gradient-echo sequence (TFE) was included. The dynamic sequence was prolonged and supplemented with furosemide provocation in some patients with suspected urinary-tract obstruction. Results. Nine percent of examinations were non-diagnostic or interrupted due to movement. MRU contributed additional information in 66 %. Nine patients with suspected urinary-tract obstruction were examined with both contrast-enhanced MRU and scintigraphy. Three MRU examinations were less informative and one equal to scintigraphy when obstruction was the diagnosis. When using a technique with a prolonged dynamic sequence, including frusemide provocation, four MRU examinations were equal and one was superior to scintigraphy. Conclusions. MRU has the potential to replace traditional diagnostic methods which use ionising radiation in paediatric patients. Further studies are needed before definite conclusions can be drawn. (orig.) With 6 figs., 3 tabs., 34 refs.

  19. Magnetic resonance urography in children – when and why?

    International Nuclear Information System (INIS)

    Vegar-Zubovic, Sandra; Kristic, Spomenka; Lincender, Lidija

    2011-01-01

    The aim of the study was to determine the potential of magnetic resonance urography (MRU) in evaluation of paediatric urinary tract pathologies. Twenty-one paediatric urological patients were evaluated with T1, T2 prior and after and 3D gradient echo sequences after the contrast administration. Results were compared with findings obtained with ultrasound which was performed to all of patients, intravenous urography performed to 14 patients with the diagnosis of hydronephrosis and voiding cystouretrography performed to 6 patients where hydronephrosis was suspected to be caused by vesicoureteral reflux (VUR). MRU not only established the cause of hydronephrosis in all 14 cases (5 ureteropelvic junction (UPJ) stenosis, 1 functional stenosis, 3 residual hydronephrosis, 1 combination of UPJ and vesico-ureteric junction (VUJ) stenosis with hydromegaureter, 2 fetal ureters and 3 insufficient broad ureteral orifices), but gave additional information about existing pathological conditions in all of patients compared to other previously performed examination (1 caliceal lithiasis, 4 UPJ stenosis, 1 VUJ stenosis, 1 neurogenic bladder, 1 hypotonic ureter, 1 urinary infection, 1 duplication of pelvis and ureter, 1 urinary retention and 1 fetal ureter). Other MRU findings were: 3 polycystic kidney disease, 1 caliceal cyst, 2 simple renal cysts, 1 long hypotonic twisted ureters and 1 hypertrophied column of Bertini. Because of the ability to acquire high contrast and spatial resolution images of the whole urinary tract in any orthogonal plane, MRU enables a precise detection and differentiation of pathological urological conditions. We believe that in the future, because of its advantages, MRU will replace traditional methods in the evaluation of urinary tract pathologies

  20. Role of vegetative nervous system in regulation of excretory function of irradiated dog stomach

    International Nuclear Information System (INIS)

    Kostesha, N.Ya.

    1989-01-01

    Dogs and rats were exposed to γ/neutron- and X-radiation. The anterior part of dog's stomach was exposed to 10 Gy and 13 Gy respectively; rats were subjected to whole-body irradiation with absolutely lethal doses. Prior to irradiation, various parts of the vegetative nervous system of both types of animals were switched off pharmocologically. In addition to clinical investigation of radiation sickness the excretory function of the stomach was studied by the excretion of intravenously injected neutral red. The switching-off of the parasympathetic nervous system prior to irradiation stabilized the excretory processes in the stomach, increased the resistance of animals, and, vice wersa, the switching-off of the sympathetic nervous system destabilized the excetory processes and decreased the resistance of the organism

  1. Quality of urography with Iopamidol and diuretic agents

    International Nuclear Information System (INIS)

    Stacul, F.; Bazzocchi, M.; Zanella, F.; Abbona, M.; Ukovich, W.

    1987-01-01

    The results obtained in four successive trials based on the analysis of urography performed on patients with normal kidney function are reported. The scores obtained with a non-ionic contrast (Iopamidol) were compared with those produced after injecting the same contrast medium with the addition of various diuretics (furosemide, various quantitives of 5% glucose solution, 20% mannitol). The results obtained by injecting the diuretic together with the Iopamidol were usually unsatisfactory. Injection of diuretic 15 ms after the Iopamidol gave better results in the lower urinary tract, particularly the bladder. The best results were obtained by injecting 250 ml, 20% mannitol, after 15 ms. However this technique is not applicable to patients requiring a voiding cystourethrogram due to the inadequate opacification of the urethra it provides

  2. Chronic pyelonephritis as false interpretation in the excretory urogram

    International Nuclear Information System (INIS)

    Rieden, K.; Weber, M.

    1985-01-01

    Chronic pyelonephritis, which is largely diagnosed via imaging procedures, is characterised by defined parenchymal scars that become manifest in the excretory urogram as contour recessions of the kidney and result in deformations of the calyces and papillae. The authors describe other renal diseases, dysplasias, variations from the standard, and artifacts resulting in similar signs on X-ray film, thus leading to the wrong diagnosis of chronic pyelonephritis. The essential differential diagnostic criteria are explained. (orig.) [de

  3. Diagnostic value of 64-slice spiral computed tomography imaging of the urinary tract during the excretory phase for urinary tract obstruction.

    Science.gov (United States)

    Zhao, De-Li; Jia, Guang-Sheng; Chen, Peng; Liu, Xin-Ding; Shu, Sheng-Jie; Ling, Zai-Sheng; Fan, Ting-Ting; Shen, Xiu-Fen; Zhang, Jin-Ling

    2017-11-01

    The present study aimed to assess the diagnostic value of 64-slice spiral computed tomography (CT) imaging of the urinary tract during the excretory phase for urinary tract obstruction. CT imaging of the urinary tract during the excretory phase was performed in 46 patients that had been diagnosed with urinary tract obstruction by B-mode ultrasound imaging or clinical manifestations. It was demonstrated that out of the 46 patients, 18 had pelvic and ureteral calculi, 12 cases had congenital malformations, 3 had ureteral stricture caused by urinary tract infection and 13 cases had malignant tumors of the urinary tract. The average X-ray dose planned for the standard CT scan of the urinary tract group 1 was 14.11±5.45 mSv, while the actual X-ray dose administered for the CT scan during the excretory phase group 2 was 9.01±4.56 mSv. The difference between the two groups was statistically significant (t=15.36; Purinary tract during the excretory phase has a high diagnostic value for urinary tract obstruction.

  4. The usefulness of T2-weighted MR urography and contrast enhanced MR urography in the evaluation of obstructive uropathy: comparisonal study with antegrade pyelography

    International Nuclear Information System (INIS)

    Oh, Chang Hoon; Lee, Jeong Min; Jin, Kong Yong; Chung, Gyung Ho; Cho, Seung Il; Lee, Sang Hun; Kim, Young Kon; Oh, Gyung Jae

    2002-01-01

    To compare the efficacy of contrast-enhanced and T2-weighted magnetic resonance urography (MRU) for the depiction of obstruction and evaluation of the causes of obstructive uropathy with that of antegrade pyelography. Twenty-five patients with obstructive uropathy who underwent percutaneous nephrostomy (PCN) and antegrade pyelography( AGP) were included in the study. We performed MR urography, comprising half-Fourier acquisition single-shot turbo spin-echo (HASTE) T2- weighted imaging and 3-D fast imaging with steady state precession (3-D FISP) T1-weighted imaging after gadolinium enhancement and compared the quality of the images of both the HASTE and 3-D FISP MRU technique in terms of their depiction of the dilated pelvocalyceal system, and the level, type, and causes of obstruction. In terms of anatomical depiction of the pelvocalyceal system (p=0.002) and the causes of obstruction (p=0.003). T1-weighted MRU using 3D-FISP was significantly better than T2-weighted MRU using the HASTE sequence. Regarding level of obstruction, T2-weighted MRU using the HASTE sequence and contrast enhanced T1-weighted MRU using 3D-FISP showed an accuracy of 76% (19/25) and 84% (21/25), respectively. In terms of type of obstruction, the accuracy of T2-weighted MRU and T1-weighted CEMRU was 72% (18/25) and 88% (22/25), respectively. T2-weighted MRU and Ta-weighted CEMRU provided both anatomical information and that relating to impaired renal function. The two modelities played a complementary role and their use could decrease the unnecessary use of invasive diagnostic examination for the evaluation of obstructive uropathy

  5. Intravenous urography and voiding cystoureterography in northern Norway: A retrospective study

    International Nuclear Information System (INIS)

    Pedersen, H.K.; Pape, J.F.; Gudmundsen, T.E.; Ostensen, H.; Tromsoe Univ.

    1986-01-01

    Intravenous urography (IU) was performed in 489 patients aged 0-9 years during 1980-1983. A total of 35 (7.2%), 19 (13.1%) boys and 16 (4.7%) girls had pathological changes at IU. Of these, 11 boys and 5 girls had findings with therapeutic consequences. We have analysed the results of IU and voiding cystoureterography (VC) in 62 patients and show that a normal IU does not exclude vesicoureteral reflux into the renal pelvis. By performing only VC hydronephrosis, pyelonephritic scarring and anomalies may be missed. (orig.)

  6. Congenital upper urinary tract abnormalities: new images of the same diseases

    Energy Technology Data Exchange (ETDEWEB)

    Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta dos [Clinica de Medicina Nuclear e Radiologia de Maceio (MedRadiUS), AL (Brazil); Miranda, Christiana Maia Nobre Rocha de; Farias, Lucas de Padua Gomes de; Padilha, Igor Gomes, E-mail: maiachristiana@globo.com [Universidade Federal de Alagoas (UFAL), Maceio, AL (Brazil)

    2013-01-15

    Congenital upper urinary tract abnormalities imply a variable clinical spectrum of morphofunctional changes ranging from asymptomatic conditions to renal failure and incompatibility with life. Computed tomography, which has overcome excretory urography imaging, has been playing a key role in the diagnosis of congenital anomalies, serving as a better guidance in the therapeutic and surgical decision-making process, besides acting as an essential tool in the identification of associated complications and aiding in the performance of minimally invasive surgery techniques. (author)

  7. Absorbed Doses to Embryo from Intravenous Urography at Selected Radiological Departments in Slovakia

    International Nuclear Information System (INIS)

    Karkus, R.; Nikodemova, D.; Horvathova, M.

    2003-01-01

    Actual legislation used in radiological protection requires quality assurance program for decreasing radiation load of patients from radiological examinations. The information about irradiation of pregnant women is very important, because the embryo is more radiosensitive as adult organism. On the basis of absence of unified calculations or measurements of absorbed doses to embryo from various radiological examinations in Slovakia we present in this study the values of absorbed doses to embryo from intravenous urography at selected radiological departments in Slovakia. Absorbed doses to embryo were obtained by measurement and calculation using the simulation of irradiation of pregnant woman by intravenous urography. The results of our study indicate, that absorbed doses to embryo were at various radiological departments considerably different, depending on type of X-ray machine and different settings of technical parameters of X-ray machine. In accordance with worldwide trend it is necessary to decrease radiation load of patients as low as possible level. Differences in radiation load between radiological departments indicate, that it is necessary to continue in solving of this problem and perform measurements and calculations of absorbed doses to embryo at different types of X-ray machines and at different examinations, where the embryo is in direct beam of X-ray. (author)

  8. Clonorchis sinensis excretory-secretory products regulate migration and invasion in cholangiocarcinoma cells via extracellular signal-regulated kinase 1/2/nuclear factor-κB-dependent matrix metalloproteinase-9 expression.

    Science.gov (United States)

    Pak, Jhang Ho; Shin, Jimin; Song, In-Sung; Shim, Sungbo; Jang, Sung-Wuk

    2017-01-01

    Matrix metalloproteinase-9 plays an important role in the invasion and metastasis of various types of cancer cells. We have previously reported that excretory-secretory products from Clonorchis sinensis increases matrix metalloproteinase-9 expression. However, the regulatory mechanisms through which matrix metalloproteinase-9 expression affects cholangiocarcinoma development remain unclear. In the current study, we examined the potential role of excretory-secretory products in regulating the migration and invasion of various cholangiocarcinoma cell lines. We demonstrated that excretory-secretory products significantly induced matrix metalloproteinase-9 expression and activity in a concentration-dependent manner. Reporter gene and chromatin immunoprecipitation assays showed that excretory-secretory products induced matrix metalloproteinase-9 expression by enhancing the activity of nuclear factor-kappa B. Moreover, excretory-secretory products induced the degradation and phosphorylation of IκBα and stimulated nuclear factor-kappa B p65 nuclear translocation, which was regulated by extracellular signal-regulated kinase 1/2. Taken together, our findings indicated that the excretory-secretory product-dependent enhancement of matrix metalloproteinase-9 activity and subsequent induction of IκBα and nuclear factor-kappa B activities may contribute to the progression of cholangiocarcinoma. Copyright © 2016 Australian Society for Parasitology. Published by Elsevier Ltd. All rights reserved.

  9. Functional analysis in MR urography - made simple

    Energy Technology Data Exchange (ETDEWEB)

    Khrichenko, Dmitry; Darge, Kassa [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2010-02-15

    MR urography (MRU) has proved to be a most advantageous imaging modality of the urinary tract in children, providing one-stop comprehensive morphological and functional information, without the utilization of ionizing radiation. The functional analysis of the MRU scan still requires external post-processing using relatively complex software. This has proved to be a limiting factor in widespread routine implementation of MRU functional analysis and use of MRU functional parameters similar to nuclear medicine. We present software, developed in a pediatric radiology department, that not only enables comprehensive automated functional analysis, but is also very user-friendly, fast, easily operated by the average radiologist or MR technician and freely downloadable Virtual Machine is required for the installation, which is obtained at no charge. The analysis software, known as ''CHOP-fMRU,'' has the potential to help overcome the obstacles to widespread use of functional MRU in children. (orig.)

  10. Comparison between the efficacy of dimeric and monomeric non-ionic contrast media (iodixanol vs iopromide) in urography in patients with macroscopic haematuria

    International Nuclear Information System (INIS)

    Stacul, F.; Cova, M.; Pravato, M.; Floriani, I.

    2003-01-01

    Non-ionic dimers induce less diuresis than non-ionic monomers, resulting in increased opacification of the urinary tract in intravenous urography. This trial compared the diagnostic efficacy of iodixanol and iopromide in patients with macroscopic haematuria. One hundred consecutive patients with normal renal function and macroscopic haematuria entered a double blind, comparative, randomised, parallel trial. Contrast media were given with bolus injection in doses of 300 mgI/kg b.w. Radiographs were blindly evaluated by three radiologists who analysed different parameters (calyceal density and filling, papillary blush detection, delineation of collecting ducts, renal pelvis opacification, visualisation of ureters, bladder density, bladder distention) and estimated the diagnostic confidence (whether abnormal findings were definitely absent, probably absent, doubtful, probably present or certainly present). Radiological diagnoses were compared with final diagnoses. Results were summarised as the ratio of the odds of having a worse performance of iopromide vs iodixanol. Iodixanol showed a significantly better calyceal density and filling [odds ratio (OR): 1.96; 95% confidence interval (CI): 1.60-2.41], a significantly better pelvis opacification (OR 2.91; CI 2.02-4.18) and a significantly more frequent papillary blush detection (OR 1.95; CI 1.29-2.95). Iopromide showed a significantly better ureteral visualisation (OR 0.67; CI 0.48-0.92) and a significantly higher bladder distention (OR 0.59; CI 0.36-0.99). Iodixanol allowed a significantly higher diagnostic confidence as to calyceal evaluation (OR 1.35; CI 1.01-1.79). No significant differences were found with regard to other parameters. The results confirmed theoretical expectations. The higher opacification provided by iodixanol allowed better results and a higher diagnostic confidence in the upper excretory pathway. (orig.)

  11. Multidetector computed tomography urography for diagnosing upper urinary tract urothelial tumour.

    Science.gov (United States)

    Cowan, Nigel C; Turney, Ben W; Taylor, Nia J; McCarthy, Catherine L; Crew, Jeremy P

    2007-06-01

    To evaluate multidetector computed tomography urography (MDCTU) for diagnosing upper urinary tract (UUT) urothelial tumour by comparison with retrograde ureteropyelography (RUP). MDCTU and RUP were used in a selected series of adult patients presenting with haematuria. Entry criteria were based on findings on intravenous urography and were chosen to ensure a high prevalence of UUT urothelial tumour to allow a valid retrospective comparison of the diagnostic techniques. MDCTU and RUP studies were scored for the presence and absence of UUT urothelial tumour by two radiologists, retrospectively and independently, and while unaware of the demographic and clinical information. The reference standards were the histopathology and clinical follow-up. MDCTU and RUP were used in 106 patients over a 24-month period. RUP was attempted in 151 of 212 UUTs; the corresponding MDCTU for each UUT was reviewed. MDCTU was a true-positive (TP) for urothelial tumour in 31, true-negative (TN) in 111, false-positive (FP) in eight and false-negative (FN) in one UUT, giving a sensitivity of 0.97, a specificity of 0.93, a positive predictive value (PPV) of 0.79 and a negative PV (NPV) of 0.99. RUP was technically successful and diagnostic in 96% of the UUTs (143/151). For diagnosing urothelial tumour, RUP was TP in 26, TN in 112, FP in four and FN in one UUT, giving a sensitivity of 0.97, specificity of 0.93, a PPV of 0.79 and NPV of 0.99. This study validates quantitatively the use of MDCTU for diagnosing UUT urothelial tumour.

  12. Comparison of computed tomographic urography, magnetic resonance urography and the combination of diffusion weighted imaging in diagnosis of upper urinary tract cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Guang-yu; Lu, Qing; Wu, Lian-ming [Department of Radiology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, No. 1630, Dongfang Road, Pudong, Shanghai 200120 (China); Zhang, Jin [Department of Urinary Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, No. 1630, Dongfang Road, Pudong, Shanghai 200120 (China); Chen, Xiao-xi [Department of Radiology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, No. 1630, Dongfang Road, Pudong, Shanghai 200120 (China); Xu, Jian-rong, E-mail: renjixujr@163.com [Department of Radiology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, No. 1630, Dongfang Road, Pudong, Shanghai 200120 (China)

    2014-06-15

    Purpose: To evaluate the performance of computed tomographic urography (CTU), static-fluid magnetic resonance urography (static-fluid MRU) and combinations of CTU, static-fluid MRU and diffusion weighted imaging (DWI) in the diagnosis of upper urinary tract cancer. Material and Methods: Between January 2010 and June 2011, patients with suspected UUT cancer underwent CTU, static-fluid MRU and DWI (b = 1000 s/mm{sup 2}) within a 1-week period. The diagnostic performances of CTU, static-fluid MRU and combinations of CTU, static-fluid MRU and DWI for upper urinary tract cancer were prospectively evaluated. The ureteroscopic and histopathologic findings were compared with the imaging findings. Results: Compared to static-fluid MRU alone (sensitivity: 76/75%, reader 1/reader 2), combining DWI with MRI can increase the sensitivity (sensitivity: 84/84%, p = 0.031/p = 0.016) of upper urinary tract cancer diagnosis. CTU had greater sensitivity (95/94%) and accuracy (92/91%) than both static-fluid MRU (sensitivity: p < 0.001/p < 0.001 and accuracy: 83/81%, p = 0.001/p < 0.001) and static-fluid MRU with DWI (sensitivity: p = 0.023/p = 0.039 and accuracy: 87/85%, p = 0.042/p = 0.049) for the diagnosis of upper urinary tract cancers. Compared with CTU alone, CTU with DWI did not significantly increase sensitivity, specificity or accuracy. However, the diagnostic confidence was improved when the combined technique was used (p = 0.031/p = 0.024). Moreover, there was no significant change in sensitivity, specificity, accuracy or diagnostic confidence when static-fluid MRU was used in combination with CTU and DWI. Conclusion: Although there is a potential role for static-fluid MRU and static-fluid MRU with DWI in urinary tract imaging, CTU is still the better choice for the diagnosis of upper urinary tract cancer. Combining DWI with CTU can help improve confidence in upper urinary tract cancer diagnoses.

  13. Computed tomography urography in non malignant kidney diseases – how to overcome one of the disadvantages?

    International Nuclear Information System (INIS)

    Al-Amin, M.

    2013-01-01

    Full text: Introduction: Computed tomography urography is among the fastest growing imaging directions, indications of which continue to change. Radiation dose is one of its main disadvantages. There are a number of literary publications regarding how to reduce radiation dose: by voltage, by mA or by reducing the number of phases. What you will learn: We present the initial experience in the diagnosis of non-malignant kidney disease with three low-dose study protocol: a standard low dose, low dose and low dose introduced by us. Our research is based on three groups of patients. The first of 36 men and 22 women viewed with repetitive low-dose protocol: 120 kV / 219 effective milliampere. The second and third group of 16 men and 9 women, respectively: 100/ 163 and 80/115 . Discussion: There have been a number of studies to reduce the radiation dose that is considered one of the main disadvantages of computed tomography urography. Reducing mA (≤ 30 mAs), leads to the radiation dose similar to that of an overview abdominal radiography. Reducing of 140 kV to 120, reducing the dosage of the skin by about 33 % and decreasing it to 80 kilovolts, the result is about 70 %. Another technology to reduce radiation exposure is by reducing the number of phases of the study, but studies have shown that the removal of the native phase is not desirable. Conclusion: We believe that computed tomography urography is a detailed study that should be applied in certain clinical indications. Its major disadvantage is the radiation dose. Images obtained with low-dose protocols are newly comparable image quality to the standard, but with much lower radiation exposure

  14. Diagnostic imaging in children with urinary tract infection: the role of intravenous urography

    DEFF Research Database (Denmark)

    Hansen, A; Wagner, A A; Lavard, L D

    1995-01-01

    Ninety children referred to hospital with urinary tract infection (UTI) were investigated by iv urography (IVU), ultrasonography (US) and 99mTc dimercaptosuccinic acid scan (DMSA). Fifty-eight children also underwent micturating cystourethrography (MCUG). In 36 (40%) of the children, at least one...... important for treatment or prognosis. IVU is an important supplement to US and DMSA in investigation programs for children with UTI. IVU should be performed in cases of renal scars, dilatations or in children with recurrent infections....

  15. Computed tomography-urography for upper urinary tract imaging: is it required for all patients who present with hematuria?

    NARCIS (Netherlands)

    Cauberg, Evelyne C. C.; Nio, C. Y.; de la Rosette, Jean M. C. H.; Laguna, M. Pilar; de Reijke, Theo M.

    2011-01-01

    To define in which patients who present with microscopic or macroscopic hematuria CT urography (CTU) is indicated as an imaging mode for the upper urinary tract (UUT). We conducted a prospective study on consecutive patients who attended a modern protocol-driven hematuria clinic from January 2006 to

  16. Endoscopic placement of ureteral stents for treatment of congenital bilateral ureteral stenosis in a dog.

    Science.gov (United States)

    Lam, Nathaniel K; Berent, Allyson C; Weisse, Chick W; Bryan, Christine; Mackin, Andrew J; Bagley, Demetrius H

    2012-04-15

    A 5-year-old 8.6-kg (18.9-lb) spayed female Pug was evaluated because of chronic hematuria and recurrent urinary tract infections. Excretory urography, ultrasonography, and excretory CT urography were performed. Results indicated that the dog had bilateral hydronephrosis and hydroureter and suspected proximal ureteral stenosis. Retrograde ureteropyelography confirmed the presence of stenosis at the ureteropelvic junction of each ureter, along with a large amount of endoluminal ureteral debris. Clinical findings suggested that the dog had a congenital bilateral anomaly of the upper urinary tract. The dog was anesthetized, and 2 double-pigtail ureteral stents were placed cystoscopically with fluoroscopic guidance for immediate relief of the ureteropelvic junction obstructions. Each stent extended from the left or right renal pelvis to the urinary bladder. The procedures and the patient's recovery from anesthesia were uncomplicated. Continuing improvements in severity of hydronephrosis, hydroureter, and dysuria were evident during routine follow-up examinations at 2, 4, 12, 16, and 45 weeks after stent placement. Over the subsequent 12 months, all clinical signs remained resolved other than a urinary tract infection that was successfully treated with antimicrobials. Ureteral stenosis should be considered as a differential diagnosis for hydronephrosis in dogs, particularly when urinary tract calculi or neoplasia is not present. Chronic hematuria and recurrent urinary tract infections can be associated with this condition. Placement of ureteral stents may be a successful treatment option for ameliorization of congenital ureteral obstructions.

  17. Radiation Doses in Intravenous Urography And Potentials For Optimization

    International Nuclear Information System (INIS)

    Halato, M.A.; Badawi, A.; Gassom, G.A.; Barsham, M.A.; Ibrahim, A.F.; Suliman, I.I.; Sulieman, A.A.

    2011-01-01

    In this study radiation doses in IVU clinical examinations were measured in three public hospitals and a sample of 44 patients. In each room the machine output was measured for different peak tube voltages. Patient's data such as (age and weight) and exposure parameters (kVp) and mAs) were recorded. Entrance Surface Air Kerma (ESAK) for patients was determined by using the tube output and the patient exposure parameters. The ESAK ranged from 0.76 to 6.75 mGy. The cumulative ESAK ranged from 3.5 to 34.6 mGy. In conclusion, the obtained results are in agreement with the standard reference ESAK levels. The study showed that the cumulative ESAK can approach a level known to increase the probability of stochastic effect. Keywords: Patient dose, intravenous Urography, radiation protection

  18. Accuracy of intermediate dose of furosemide injection to improve multidetector row CT urography

    International Nuclear Information System (INIS)

    Roy, Catherine; Jeantroux, Jeremy; Irani, Farah G.; Sauer, Benoit; Lang, Herve; Saussine, Christian

    2008-01-01

    Objective: Evaluate the usefulness of intermediate dose furosemide to improve visualization of the intrarenal collecting system and ureter using MDCTU. Materials and methods: Two groups of 100 patients without urinary tract disease or major abdominal pathology underwent MDCTU. Group I (various abdominal indications) was performed without any additional preparation and Group II (suspicion of urinary tract disease) 10 min after injection of furosemide (20 mg). MIP images of the excretory phase were post-processed. Maximal short-axis diameter of the pelvis and ureter were measured on axial images for all phases. Visualization of the collecting system wall and the identification of the whole ureter were assessed. Results: Mean pelvic diameter before contrast was (7.4 mm, S.D. ± 2.7; 13.4 mm, S.D. ± 4.1), on cortico-medullary phase (8.4 mm, S.D. ± 4.2; 14.3 mm, S.D. ± 4), on nephrographic phase (8.1 mm, S.D. ± 2.5; 14.8 mm, S.D. ± 4) and on excretory phase (9.7 mm, S.D. ± 3.4; 14.9 mm, S.D. ± 4.5), respectively, for Groups I and II. Intrarenal collecting system wall was clearly identified on both corticomedullary and nephrographic phases in 91% of Group II against 20% of Group I. Opacification of the entire ureter was excellent on excretory phase in 96% of Group II against 13% of Group I. The difference between the mean values for the two groups was statistically significant for all phases (p -9 ). Conclusion: Intermediate-dose furosemide (20 mg) before MDCTU is a very simple add-on for accurate depiction of pelvicalyceal details and collecting system wall without artefacts. The procedure is associated with a constant and complete visualisation of the entire urete

  19. Accuracy of intermediate dose of furosemide injection to improve multidetector row CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Catherine [Department of Radiology B, Universitary Hospital of Strasbourg-Civil Hospital, 1, Place de l' hopital BP 426, 67091 Strasbourg Cedex (France)], E-mail: catherine.roy@chru-strasbourg.fr; Jeantroux, Jeremy; Irani, Farah G.; Sauer, Benoit [Department of Radiology B, Universitary Hospital of Strasbourg-Civil Hospital, 1, Place de l' hopital BP 426, 67091 Strasbourg Cedex (France); Lang, Herve; Saussine, Christian [Department of Urology, Universitary Hospital of Strasbourg-Civil Hospital, 1, Place de l' hopital BP 426, 67091 Strasbourg Cedex (France)

    2008-05-15

    Objective: Evaluate the usefulness of intermediate dose furosemide to improve visualization of the intrarenal collecting system and ureter using MDCTU. Materials and methods: Two groups of 100 patients without urinary tract disease or major abdominal pathology underwent MDCTU. Group I (various abdominal indications) was performed without any additional preparation and Group II (suspicion of urinary tract disease) 10 min after injection of furosemide (20 mg). MIP images of the excretory phase were post-processed. Maximal short-axis diameter of the pelvis and ureter were measured on axial images for all phases. Visualization of the collecting system wall and the identification of the whole ureter were assessed. Results: Mean pelvic diameter before contrast was (7.4 mm, S.D. {+-} 2.7; 13.4 mm, S.D. {+-} 4.1), on cortico-medullary phase (8.4 mm, S.D. {+-} 4.2; 14.3 mm, S.D. {+-} 4), on nephrographic phase (8.1 mm, S.D. {+-} 2.5; 14.8 mm, S.D. {+-} 4) and on excretory phase (9.7 mm, S.D. {+-} 3.4; 14.9 mm, S.D. {+-} 4.5), respectively, for Groups I and II. Intrarenal collecting system wall was clearly identified on both corticomedullary and nephrographic phases in 91% of Group II against 20% of Group I. Opacification of the entire ureter was excellent on excretory phase in 96% of Group II against 13% of Group I. The difference between the mean values for the two groups was statistically significant for all phases (p < 10{sup -9}). Conclusion: Intermediate-dose furosemide (20 mg) before MDCTU is a very simple add-on for accurate depiction of pelvicalyceal details and collecting system wall without artefacts. The procedure is associated with a constant and complete visualisation of the entire urete.

  20. Pediatric ureteropelvic junction obstruction: can magnetic resonance urography identify crossing vessels?

    Energy Technology Data Exchange (ETDEWEB)

    Parikh, Kushal R.; Kraft, Kate H.; Ivancic, Vesna; Smith, Ethan A.; Dillman, Jonathan R. [Section of Pediatric Radiology, Mott Children' s Hospital, Department of Radiology, University of Michigan Health System, Ann Arbor, MI (United States); Hammer, Matthew R. [University of Texas Southwestern, Department of Radiology, Dallas, TX (United States)

    2015-11-15

    MR Urography (MRU) is an increasingly used imaging modality for the evaluation of pediatric genitourinary obstruction. To determine whether pediatric MR urography (MRU) reliably detects crossing vessels in the setting of suspected ureteropelvic junction (UPJ) obstruction. The clinical significance of these vessels was also evaluated. We identified pediatric patients diagnosed with UPJ obstruction by MRU between May 2009 and June 2014. MRU studies were evaluated by two pediatric radiologists for the presence or absence of crossing vessels. Ancillary imaging findings such as laterality, parenchymal thinning/scarring, trapped fluid in the proximal ureter, and presence of renal parenchymal edema were also evaluated. Imaging findings were compared to surgical findings. We used the Mann-Whitney U test to compare continuous data and the Fisher exact test to compare proportions. Twenty-four of 25 (96%) UPJ obstructions identified by MRU were surgically confirmed. MRU identified crossing vessels in 10 of these cases, with 9 cases confirmed intraoperatively (κ = 0.92 [95% CI: 0.75, 1.0]). Crossing vessels were determined to be the primary cause of UPJ obstruction in 7/9 children intraoperatively, while in two children the vessels were deemed incidental and noncontributory to the urinary tract obstruction. There was no significant difference in age or the proportions of ancillary findings when comparing children without and with obstructing vessels. MRU allows detection of crossing vessels in pediatric UPJ obstruction. Although these vessels are the primary cause of obstruction in some children, they are incidental and non-contributory in others. Our study failed to convincingly identify any significant predictors (e.g., age or presence of renal parenchymal edema) that indicate when a crossing vessel is the primary cause of obstruction. (orig.)

  1. CT urography: a comparison of strategies for upper urinary tract opacification

    Energy Technology Data Exchange (ETDEWEB)

    Sanyal, Rupan; Deshmukh, Amol; Singh Sheorain, Virender; Taori, Kishor [Government Medical College, Department of Radiology, Nagpur (India)

    2007-05-15

    A consensus is yet to be reached regarding the best strategy for ensuring maximum ureteric delineation during CT urography (CTU). In this study we have compared various CTU protocols to try to establish the best method for ureteric delineation. Saline infusion in the supine position, saline infusion in the prone position, furosemide administration (10 mg, iv) and buscopan administration (20 mg iv) with saline infusion in the prone position were tried in four groups, each having 15 patients who were undergoing CTU. The pelvicalyceal system and ureter were divided into six segments, to each of which an opacification score was assigned (0, unopacified segment; 1, less than 50% opacified segment; 2, 50-99% of the segment opacified; or 3, completely opacified segment) and the results compared. Furosemide administration resulted in complete opacification of 93% of the ureters (28 of 30). In the distal (below the sciatic notch) ureter, the mean score with furosemide was 2.9, while that with saline, supine and prone positioning was 1.87 and 1.83, respectively, and this difference was highly significant (P = 0.0002 and P = 0.0001). It was also significantly higher than the buscopan group (score 2.3, P = 0.002). Also in the lower (the iliac crest to the sciatic notch) and upper (above the iliac crest) ureter, furosemide had significantly higher scores than saline infusion in either position. Saline infusion in the supine and prone positions had very similar scores in all segments that were less than the buscopan group, but this difference was not statistically significant. During CT urography, furosemide administration in low doses is the most effective and convenient technique for ureteric opacification. (orig.)

  2. CT urography: a comparison of strategies for upper urinary tract opacification

    International Nuclear Information System (INIS)

    Sanyal, Rupan; Deshmukh, Amol; Singh Sheorain, Virender; Taori, Kishor

    2007-01-01

    A consensus is yet to be reached regarding the best strategy for ensuring maximum ureteric delineation during CT urography (CTU). In this study we have compared various CTU protocols to try to establish the best method for ureteric delineation. Saline infusion in the supine position, saline infusion in the prone position, furosemide administration (10 mg, iv) and buscopan administration (20 mg iv) with saline infusion in the prone position were tried in four groups, each having 15 patients who were undergoing CTU. The pelvicalyceal system and ureter were divided into six segments, to each of which an opacification score was assigned (0, unopacified segment; 1, less than 50% opacified segment; 2, 50-99% of the segment opacified; or 3, completely opacified segment) and the results compared. Furosemide administration resulted in complete opacification of 93% of the ureters (28 of 30). In the distal (below the sciatic notch) ureter, the mean score with furosemide was 2.9, while that with saline, supine and prone positioning was 1.87 and 1.83, respectively, and this difference was highly significant (P = 0.0002 and P = 0.0001). It was also significantly higher than the buscopan group (score 2.3, P = 0.002). Also in the lower (the iliac crest to the sciatic notch) and upper (above the iliac crest) ureter, furosemide had significantly higher scores than saline infusion in either position. Saline infusion in the supine and prone positions had very similar scores in all segments that were less than the buscopan group, but this difference was not statistically significant. During CT urography, furosemide administration in low doses is the most effective and convenient technique for ureteric opacification. (orig.)

  3. Liver excretory function in patients with inflammatory diseases of the bile duct as reflected by radioimmunoassays of choleglycine

    International Nuclear Information System (INIS)

    Buyanov, V.M.; Orduyan, S.L.; Gidzev, M.Sh.; Kasimov, A.O.

    1989-01-01

    Radioimmunoassays of holeglycine in 41 healthy donors, 37 patients with gastroduodenal diseases and 41 ones with inflammatory diseases of the bile ducts have revealed that impaired excretory function of the liver is associated with a reduced coefficient of the bile acid extraction and a decreased bactericidal activity of the bile. The latter fact is conductive to active growth of microorganisms in the bile and thus promotes postoperative septic complications. Early detection of cholestasis resultant froom impaired excretory function with the use of choleglycine radioimmunoassays permits administration of early measures to restore the bile passage and of rational antibacterial therapy to prevent postoperative pyoseptic complications

  4. Intravenous digital subtraction angiography of transplanted kidney artery

    International Nuclear Information System (INIS)

    Tessier, J.P; Teyssou, H.; Verdier, J.P.; Tison, E.; Meyblum, J.; Marchal, M.

    1986-01-01

    Results of 351 intravenous digital subtraction angiographs (AN) of transplanted kidneys emphasized reliability of this examination for detection of renal artery stenosis. A prospective study of 219 patients (188 interpretable AN) showed significant stenosis of grafted artery in 22% of cases: 17% of the 126 patients with normal blood pressure and 34% of the 62 cases of hypertension. Digital subtraction allows, with a single injection, assessment of renal artery, nephrogram and excretory cavities, but it is not a substitute for conventional intravenous urography 1 to 2 months after grafting [fr

  5. Medullary sponge kidney on axial computed tomography

    International Nuclear Information System (INIS)

    Ginalski, J.-M.; Schnyder, Pierre; Portmann, Luc; Jaeger, Philippe

    1991-01-01

    To evaluate features of medullary sponge kidney (MSK) on computed tomography (CT), 4-mm-thick axial slices without intravenous contrast material were 1st made in 13 patients through 24 kidneys which showed images of MSK on excretory urograms. On CT, papillary calcifications were found in 11 kidneys. In 5 of these, the calcifications were not detectable on plain films. Some hyperdense papillae (attenuation value 55-70 Hounsfield units) without calcification were found in 4 other kidneys. 9 kidneys appeared normal. 10 of the 14 kidneys were reexamined by a 2nd series of 4-mm-thick axial slices, 5 min after intravenous injection of 50 ml of Urografin. Images suggesting possible ectasia of precaliceal tubules were found in only 4 kidneys. These images appear much less obvious and characteristic on CT than on excretory urogram and do nothing more than suggest the possibility of MSK. In conclusion, the sensitivity of CT in the detection of MSK is markedly lower than that of excretory urography. In the most florid cases of the disease, CT can only show images suggesting the possibility of MSK. On the other hand, CT appears much more sensitive than plain films and tomograms of excretory in the detection of papillary calcifications, the most frequent complication of MSK. (author). 13 refs.; 3 figs

  6. Comparison of Excretory-Secretory and Somatic Antigens of Ornithobilharzia turkestanicum in Agar Gel Diffusion Test

    Directory of Open Access Journals (Sweden)

    H Miranzadeh

    2008-12-01

    Full Text Available Background: Ornithobilharziosis as one of the parasitic infections may give rise to serious economic problems in animal husbandry. The Aim of the study was to prepare and compare the somatic and excretory-secretory (ES antigens of O. tur­kestanicum in gel diffusion test. Methods: Excretory-secretory (ES and somatic antigens of Ornithobilharzia turkestanicum were prepared from collected worms from mesentric blood vessels of infected sheep. The laboratory bred rabbits were immunized with antigens and then antisera were prepared. The reaction of antigens and antisera was observed in gel diffusion test. Results: ES antigens of this species showed positive reaction with antisera raised against ES and also somatic antigens. Somatic antigens also showed positive reaction with antisera raised against somatic and also ES antigens. Conclusion: The antigenicity of O. turkestanicum ES and somatic antigens is the same in gel diffusion test.

  7. Measurement of patient radiation doses in certain urography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Zailae, A.; Abuderman, A.; Theodorou, K.

    2015-01-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urological procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethrogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. (authors)

  8. Single-phase DECT with VNCT compared with three-phase CTU in patients with haematuria

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Jae; Park, Byung Kwan; Kim, Chan Kyo [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-10-15

    To retrospectively evaluate the diagnostic performance of single-phase dual-energy CT (DECT) with virtual non-contrast CT (VNCT) compared with three-phase CT urography (CTU) in patients with haematuria. A total of 296 patients underwent three-phase CTU (NCT at 120 kVp; nephrographic phase and excretory phase DECTs at 140 kVp and 80 kVp) owing to haematuria. Diagnostic performances of CT scans were compared for detecting urothelial tumours and urinary stones. Dose-length product (DLP) was compared in relation to single-phase DECT and three-phase CTU Dose-length product (DLP) was compared in relation to single-phase DECT and three-phase CTU. Sensitivity and specificity for tumour were 95 % (19/20) and 98.9 % (273/276) on CTU, 95 % (19/20) and 98.2 % (271/276) on nephrographic phase DECT, and 90 % (18/20) and 98.2 % (271/276) on excretory phase DECT (P > 0.1). Of the 148 stones detected on NCT, 108 (73 %) and 100 (67.6 %) were detected on nephrographic phase and excretory phase VNCTs, respectively. The mean size of stones undetected on nephrographic and excretory VNCTs was measured as 1.5 ± 0.5 mm and 1.6 ± 0.6 mm, respectively. The mean DLPs of three-phase CTU, nephrographic phase DECT and excretory phase DECT were 1076 ± 248 mGy . cm, 410 ± 98 mGy . cm, and 360 ± 87 mGy . cm, respectively (P < 0.001). Single-phase DECT has a potential to replace three-phase CTU for detecting tumours with a lower radiation dose. (orig.)

  9. Rapid contrast infusion of bolus injection for i.v. urography

    International Nuclear Information System (INIS)

    Kaltenborn, H.; Klose, P.; Klose, K.; Schmiedel, E.

    1993-01-01

    The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the use of bolus injections but pressure injections are unnecessary from a diagnostic point view. (orig.) [de

  10. Antigenic analyses of tissues and excretory and secretory products from Strongylus vulgaris.

    OpenAIRE

    Wynne, E; Slocombe, J O; Wilkie, B N

    1981-01-01

    Rabbit antisera were prepared against veronal buffered saline extracts of L4 and L5 Strongylus vulgaris, adult S. vulgaris and adult Strongylus equinus retrieved from naturally infected horses. In agar gel diffusion with these antisera, adult S vulgaris and S. equinus each appeared to have at least one unique antigen; larval S. vulgaris appeared to have two species-specific and two stage-specific antigens. There were several common antigens. Excretory and secretory products were collected als...

  11. MRI of cul-de-sac endometriosis

    International Nuclear Information System (INIS)

    Balestrini, Maria A.; Martin, Eduardo; Gomez Sanetta, Santiago; De Lucas, Federico; Bruno, Claudio; Sanchez Marull, Ricardo; Villamayor, Irene

    2000-01-01

    The endometriosis is a gynecological disorder characterized by the presence of ectopic functioning endometrial tissue. According to different studies, the incidence of endometriosis in fertile women oscillates between 10% and 15%. There are many theories (Sampson or menstrual blood transport, coelomic methaplasia, lymphatic dissemination, blood, etc.) that take part in the ethiopatogenic explanation of the disease. The findings obtained by excretory urography, computed tomography (CT), magnetic resonance imaging (MRI), cytology and histology in a 31 years old patient with cul-de-sac endometriosis is presented. MRI was the imaging method of choice for diagnosis and follow-up after treatment of this condition. (author)

  12. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  13. Pediatric excretory MR urography: comparative study of enhanced and non-enhanced techniques

    Energy Technology Data Exchange (ETDEWEB)

    Borthne, Arne S. [Department of Pediatric Radiology, Kirkeveien 166, Ullevaal University Hospital, 0407 Oslo (Norway); Pierre-Jerome, Claude [Department of Central Radiology, Ullevaal University Hospital, Kirkeveien 166, 0407 Oslo (Norway); Gjesdal, Kjell I.; Storaas, Tryggve; Courivaud, Frederic [Department of Medical Physics, Ullevaal University Hospital, Kirkeveien 166, 0407 Oslo (Norway); Eriksen, Morten [Institute of Experimental Research, Ullevaal University Hospital, Kirkeveien 166, 0407 Oslo (Norway)

    2003-06-01

    Our purpose was to compare the quality of ureteral imaging in pediatric patients using two different MR sequences: the non-enhanced heavily T2-weighted (W) turbo spin-echo sequence (TSE) and the gadolinium-enhanced T1W fast-field-echo sequence (T1 FFE). An experimental study on three pigs was first performed. The TSE, before and after furosemide injection, was followed by the T1 FFE sequence. The clinical study included 11 infants and 10 children. With some modifications the same MR parameters and techniques were used as in the animal study. The TSE with TR 8000 ms and TE 650 ms implied 6 radial stacks each of 40 mm thickness. The T1 FFE included TR 18 ms, TE 2.9 ms, flip angle 60, and 50 slices with thickness 0.7 mm. After post-processing, image reconstructions qualitative and quantitative analysis were performed. Complete visualization of the ureters was achieved in 35 of 42 (83%) cases. Seventy-four percent of the ureters were completely visualized with T1 FFE compared with only 19% with TSE. Sixty-nine percent of the ureters were better imaged with T1 FFE than TSE and 21% equally well imaged. Four ureters (10%), either obstructed or due to poor renal function, were better imaged with TSE. The two sequences are complementary. Visualization of non-obstructed ureters is excellent with T1 FFE and the sequence is superior to TSE. The TSE, however, may be equal to or even better than T1 FFE in visualizing obstructed ureters or ureters draining malfunctioning kidneys. (orig.)

  14. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  15. Effects of cryopreservation on excretory function, cellular adhesion molecules and vessel lumen formation in human umbilical vein endothelial cells.

    Science.gov (United States)

    Cai, Guoping; Lai, Binbin; Hong, Huaxing; Lin, Peng; Chen, Weifu; Zhu, Zhong; Chen, Haixiao

    2017-07-01

    Cryopreservation is widely used in regenerative medicine for tissue preservation. In the present study, the effects of cryopreservation on excretory function, cellular adhesion molecules and vessel lumen formation in human umbilical vein endothelial cells (HUVECs) were investigated. After 0, 4, 8, 12 or 24 weeks of cryopreservation in liquid nitrogen, the HUVECs were thawed. The excretory functions markers (endothelin‑1, prostaglandin E1, von Willebrand factor and nitric oxide) of HUVECs were measured by ELISA assay. The expression of intercellular adhesion molecule‑1 (ICAM‑1) in HUVECs was analyzed using flow cytometry. An angiogenesis assay was used to determine the angiogeneic capabilities of the thawed HUVECs. The results demonstrated that cryopreserved/thawed and recultivated HUVECs were unsuitable for tissue‑engineered microvascular construction. Specifically, the excretory function of the cells was significantly decreased in the post‑cryopreserved HUVECs at 24 weeks. In addition, the level of ICAM‑1 in HUVECs was significantly upregulated from the fourth week of cryopreservation. Furthermore, the tube‑like structure‑forming potential was weakened with increasing cryopreservation duration, and the numbers of lumen and the length of the pipeline were decreased in the thawed HUVECs, in a time‑dependent manner. In conclusion, the results of the present study revealed that prolonged cryopreservation may lead to HUVEC dysfunction and did not create stable cell lines for tissue‑engineered microvascular construction.

  16. Computed tomography as a supplement to urography in the evaluation of suspected neuroblastoma

    International Nuclear Information System (INIS)

    Siegel, M. J.; Sagel, S.S.

    1982-01-01

    Eleven children in whom a retropertioneal neuroblastoma was suspected on the basis of plain radiographic or urographic findings underwent computed tomography (CT). CT identified and localized a neurogenic tumor in eight patients. Calcifications were demonstrated by CT in six lesions, but by urography in only four. One neuroblastoma detected by CT was not seen on the urogram; in five patients greater extent of the tumor was defined by CT than by conventional radiologic procedures. In three patients CT excluded a neuroblastoma, but diagnosed other disorders (hepatic tumor, pancreatitis, and retrocaval ureter). Our results confirm that CT is a simple and accurate method for diagnosis, delineation of extent, or exclusion of neuroblastoma

  17. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  18. Characterization of the effects of erythromycin estolate and erythromycin base on the excretory function of the isolated rat liver

    International Nuclear Information System (INIS)

    Gaeta, G.B.; Utili, R.; Adinolfi, L.E.; Abernathy, C.O.; Giusti, G.

    1985-01-01

    To investigate the mechanisms of erythromycin cholestasis, the effects of erythromycin estolate (EE) on the excretory function of the isolated perfused rat liver and on liver plasma membrane (LM) preparations were studied and compared to those of erythromycin base (EB) and lauryl sulfate (LS), added alone or in combination. EE (at 125 to 200 microM) caused dose-dependent reductions of bile and perfusate flows, bile acid (BA) excretion, and biliary BA concentration. The alterations of the excretory function were only in part due to the decreased perfusate flow. In contrast, both 200 and 300 microM concentrations of EB elicited similar choleretic responses, which were presumably related to the osmotic activity of the drug excreted in the bile. LS did not affect hepatic excretory functions. However, the simultaneous addition of EB and LS resulted in a rate of bile flow lower than that observed with EB alone. EE, but not EB, increased canalicular permeability to [ 14 C]sucrose as measured by bile to plasma (B:P) ratio. Neither drugs altered [ 14 C]erythritol B:P ratio. In LM preparations both Na+,K+- and Mg2+-ATPase activities were inhibited in a dose-dependent manner by EE, but not by EB. The data suggest that EE could affect bile flow by inhibiting cotransport of Na+ and BA and by altering LM permeability and support the view that the effect of erythromycins on the liver may be related to their surface activity

  19. Patient preparation for intravenous urography: are we practising evidence-based medicine?

    International Nuclear Information System (INIS)

    Singh, S.; Reddicliffe, N.; Parker, D.A.

    2008-01-01

    Aim: To identify the current practice of patient preparation prior to intravenous urography (IVU) in England and Wales. Methods: Seventy-two hospitals were contacted to request details regarding the duration of fluid restriction, adherence to a low-residue diet, or use of laxatives for patient preparation before IVU examinations. Results: Results showed that out of 45 hospitals that still use IVU, only six (13.3%) did not follow a patient-preparation regime. The vast majority of the hospitals contacted (87.6%), implemented either fluid and/or food restriction, or prescribed laxatives. The duration of fluid and food restriction varied from 2-12 h duration, and some departments advocated 48 h of laxatives. Conclusion: A large proportion of hospitals are not practising evidence-based medicine in relation to IVU, and we suggest that the practice of patient preparation should be abandoned

  20. Simple ectopic kidney in three dogs.

    Science.gov (United States)

    Choi, Jiyoung; Lee, Heechun; Lee, Youngwon; Choi, Hojung

    2012-10-01

    Simple ectopic kidney was diagnosed in three dogs by means of radiography and ultrasonography. A 2-year-old castrated male Schnauzer, a 13-year-old female Schnauzer and a 9-year-old male Jindo were referred with vomiting, hematuria and ocular discharge, respectively. In all three dogs, oval-shaped masses with soft tissue density were observed in the mid to caudal abdomen bilaterally or unilaterally, and kidney silhouettes were not identified at the proper anatomic places on abdominal radiographs. Ultrasonography confirmed the masses were malpositioned kidney. The ectopic kidneys had relatively small size, irregular shape and short ureter but showed normal function on excretory urography.

  1. Dynamic CT of the renal parenchyma

    International Nuclear Information System (INIS)

    Ohyama, Yukio; Imanishi, Yoshimasa; Ishikawa, Tohru; Fujii, Masamichi; Uji, Teruyuki

    1985-01-01

    Normal renal dynamic CT findings of 57 cases were analysed in termes of sequential change of renal parenchymal CT image. Cortex, outer medulla and inner medulla were delineated and their sequential CT image was well correlated with the anatomicophysiological character of the kidney. Dynamic CT of 32 abnormal cases showed abnormal sequential CT findings explaining the mechanism of the abnormalities. Especially, delayed enhancement of renal cortex was noted in 17 of 19 kidneys with arterial obstruction and delayed enhancement of renal medulla in 22 of 25 cases with renal dysfunction. Compaired with excretory urography in 11 cases with renal dysfunction, advantage of dynamic CT were noted. (author)

  2. Techniques and indications in radiology

    International Nuclear Information System (INIS)

    Lange, S.

    1987-01-01

    The stated purpose of this book is to review modern radiologic diagnostic techniques as applied to the study of the kidney and urinary tract, and their pertinent indications. This goal is partially accomplished in the first two segments of the book, which consist of about 100 pages. These include a synoptic description of various techniques - including classic uroradiologic studies such as excretory urography and retrograde pyelography, plus sonography, computed tomography, angiography, and nuclear medicine. The diagnostic signs and the differential diagnoses are fairly well described, aided by a profusion of tables and diagrams. The overall quality of the reproduction of the illustrations is good

  3. Incomplete urethral duplication with cyst formation in a dog

    International Nuclear Information System (INIS)

    Duffey, M.H.; Barnhart, M.D.; Barthez, P.Y.; Smeak, D.D.

    1998-01-01

    Incomplete urethral duplication with cyst formation was diagnosed in a dog that had soft, fluctuant, subcutaneous swellings in the ventral perineal and penile areas and a history of nocturia and incontinence during recumbency that were unresponsive to treatment with antibiotics. Retrograde urethrocystography, voiding urethrography, double-contrast cystography, radiography after direct administration of contrast medium into cystic structures, and excretory urography were performed to evaluate the urinary tract. Communication between the cysts and the urethra was demonstrated radiographically only after intralesional injection of contrast medium. Nocturia and incontinence resolved after surgical removal of the urethral duplication and cysts. The dog was clinically normal 1 year after surgery

  4. The value and significance of genito-urography in the diagnosis of intersex and other malformations of the urogenital tract

    International Nuclear Information System (INIS)

    Grabenwoeger, F.; Grabenwoeger, M.; Dock, W.; Gherardini, R.; Karnel, F.

    1988-01-01

    The accuracy of genito-urography in the diagnosis of intersex and for the demonstration of the internal genitalia has been studied in 16 patients. If was found tat the radiological appearances agreed in all cases with the surgical findings. Individual malformations of the genitals have been considered with reference to the classification of Shopfner and Prader and the advantages and disadvantages of various examination techniques are discussed. (orig.) [de

  5. Renal morphology and function immediately after extracorporeal shock-wave lithotripsy

    Energy Technology Data Exchange (ETDEWEB)

    Kaude, J.V.; Williams, C.M.; Millner, M.R.; Scott, K.N.; Finlayson, B.

    1985-08-01

    The acute effects of extracorporeal shock-wave lithotripsy (ESWL) on morphology and function of the kidney were evaluated by excretory urography, quantitative radionuclide renography (QRR), and magnetic resonance imaging (MRI) in 33 consecutive patients. Excretory urograms demonstrated an enlarged kidney in seven (18%) of 41 treatments and partial or complete obstruction of the ureter by stone fragments after 15 (37%) of 41 treatments. Total effective renal plasma flow (ERPF) was not changed after ESWL, but the percentage ERPF of the treated kidney was decreased by more than 5% in 10 (30%) of 33 cases. QRR images showed partial parenchymal obstruction in 10 (25%) of 41 teated kidneys and total parenchymal obstruction in 9 (22%). MRI disclosed one or more abnormalities in 24 (63%) of 38 treated kidneys. Treated kidneys were normal by all three imaging methods in 26% and abnormal by one or more tests in 74% of cases. The morphologic and functional changes are attributed to renal contusion resulting in edema and extravasation of urine and blood into the interstitial, subcapsular, and perirenal spaces.

  6. Anatomical study of the renal excretory system in pigs. A review of its characteristics as compared to its human counterpart.

    Science.gov (United States)

    Gómez, F A; Ballesteros, L E; Estupiñán, H Y

    2017-01-01

    Despite the importance of the pyelocalyceal system in the pig as an experimental model, there is little information about this particular anatomical subject. We determined the morphological characteristics of the renal excretory system in pigs. This descriptive cross-sectional study evaluated 130 pairs of kidneys of pigs destined to slaughter. The pyelocalyceal system was subjected to injection technique - corrosion by infusion of polyester resin (85% Palatal and 15% Styrene) and subsequent infusion in potassium hydroxide (KOH) for 10 days. The significance level used was p renal excretory system is characterised by the presence of type A major cranial and caudal calyxes seen in 34.3% of the kidneys (type A1 in 30% and type A2 in 4.3%). type B calyxes, corresponding to minor calyxes draining directly into the renal pelvis, were present in 65.7% of the specimens (type B1 59.2%; type B2 6.5% of the cases). The number of minor calyxes in the collector system was 7.9 ± 2.27 with statistically significant differences in side (p = 0.0047). The morphometric characteristics of the kidneys in this study are slightly smaller than reported in humans. Similarly, the incidence of type A renal excretory system distribution is highest in humans and lowest in pigs. Due to its few morphological differences, the pig kidney is an excellent model for teaching- -learning processes, for research purposes, and for training of urologic applications.

  7. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  8. Reduction method of the radiation dose for the urography in children

    International Nuclear Information System (INIS)

    Ohtake, Kazuo; Chiba, Nobuyuki; Terashima, Kazumitsu

    1976-01-01

    An Al-Filter corresponding to the half value layer of exposure voltage was used at the lower abdomen to protect the sexual gland, when the urography was done. In I.V.P., the picture was taken by covering the site lower than the illiac region with an Al-Filter, Supposing that an ovary is located at the one-half of the thickness of the abdomen, exposure dose to the sexual gland was determined using the Mix D P phantom. The dose exposed at 56 kv, 2mAs was 5.2 mRad in the skin. On the other hand, it was decreased to one-half dose (2.6 mRad) in the skin by exposured with filter. The exposure dose to the sexual gland was decreased to about 20% of non-filter exposure. It was decreased to 45% at 72 kv, 8 mA. Therefore, the Al-Filter can reasonably reduce exposure dose to the sexual gland. (serizawa, K.)

  9. Magnetic resonance urography in pediatrics: utilization of ultrafast single-shot spin echo sequences

    International Nuclear Information System (INIS)

    Martin, C.; Martin, J.; Duran, C.; Rigol, S.; Rojo, J. C.

    1999-01-01

    To determine the value of magnetic resonance urography (MRU) using ultrafast single-shot (SS) rapid acquisition with relaxation enhancement (RARE) and half-Fourier (HF) SS-RARE (SS-HF-RARE or HASTE) in the evaluation of congenital urinary tract anomalies in pediatric patients, and their possible application as alternatives to intravenous urography (IVU). Eighteen children (11 boys and 7 girls) aged 2 months to 15 years (mean: 5 years) with a total of 19 congenital urinary tract anomalies were studies by MU using SS-RARE and HASTE sequences in a 1 Tesla scanner. All the patients had previously been studies by ultrasound (US) and IVU. Twelve patients required anesthesia. The images were acquired by means of a HASTE sequence with multisection technique (TR, infinite; TE e f, 87 msec; echo train, 128; interval between echoes, 10.9 msec; total acquisition time, 13 sections/12 seconds), and SS-RARE (TR, infinite; TE e f, 1.100 msec; echo train, 240, and acquisition time, 7 seconds). Four radiologists evaluated the images independently; two who reviewed the IV images in consensus and two who reviewed the MRU images in consensus. The images were evaluated to assess the dilatation of the urinary tract and their utility in detecting the level and cause of the obstruction. MRU images revealed the urinary tract dilation, the level of the obstruction and the type of anomaly in 18 patients (100%), while IVU provided this information in only 10 [ sensitivity, 53%, 95% confidence interval (29%, 76%)]. The mean time required for MRU was 20 minutes (range: 7 to 30 minutes), while that of IVU was 1,242 minutes (range: 45 to 1,440 minutes). MRU using ultrafast single-short spin echo sequences is a rapid and effective technique that permits and excellent evaluation of congenital urinary tract anomalies in pediatric patients and does not require the administration of contrast media or ionizing radiation. (Author) 10 refs

  10. Detailed evaluation of the upper urinary tract in patients with prune belly syndrome using magnetic resonance urography.

    Science.gov (United States)

    Garcia-Roig, M L; Grattan-Smith, J D; Arlen, A M; Smith, E A; Kirsch, A J

    2016-04-01

    Magnetic resonance urography (MRU) has proven to be useful in the setting of complex urologic anatomy. Prune belly syndrome (PBS) patients are known to have malformed and highly variable urinary tract anatomy due to significant dilation and renal dysplasia. To further characterize the renal and ureteral anatomy and renal function in patients with PBS via MRU. Children with PBS undergoing MRU (2006-2011) were identified. Studies were performed to evaluate severe hydronephrosis in all patients. Demographics, previous imaging, and MRU findings were collected. A single radiologist reviewed all studies. MRU was performed on 13 boys, with a median age of 29.3 months (IQR 6-97). Two patients underwent >1 study for ureteropelvic junction obstruction (UPJ obstruction) and calyceal diverticulum with a solitary kidney, respectively. Hydroureteronephrosis (HUN) was identified in 12 boys (92%), while one (8%) did not have ureteral dilation. All patients demonstrated morphologic abnormalities beyond HUN as follows: five (38%) renal dysplasia; five (38%) scarring; four (31%) calyceal diverticula; and three (23%) thickened bladder. The median renal transit time (RTT) was 6 min (IQR 3.5-10.5), and >8 min (range 8.5-35) in six patients; one patient was ultimately diagnosed with obstruction. The mean serum creatinine was 0.5 ± 0.3 mg/dl. This summary figure is a coronal excretory phase T1 MRU image demonstrating absence of well-defined calyces and a 5-cm calyceal diverticulum (white arrow). This study reports significant anatomic and functional findings on MRU that were not readily apparent when using standard imaging for children with PBS. The high-resolution images and functional data obtained with MRU allowed for visualization of calyceal diverticula and abnormal renal pelvic anatomy not previously described in PBS. In addition, renal dysplasia could be identified with MRU, which is badly characterized in the PBS population outside of renal biopsy studies. Potential limitations

  11. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  12. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  13. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  14. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  15. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  16. Extended radionuclide urography (ERU). A new diagnostic technique in urinary tract infection in children

    International Nuclear Information System (INIS)

    Mueller-Brand, J.; Fliegel, C.; Leititis, J.

    1982-01-01

    Radionuclide renal studies with 99m-Tc-diethylene-triamine-pentaacetate (99m-Tc-DTPA) are commonly used to assess renal perfusion, glomerular filtration and excretion. One of the two remaining problems in pediatric urology is the difficulty in determining the significance of upper urinary tract dilatation. The second is the need for a safe, non-invasive and reliable method to detect and quantify vesicoureteral reflux. Using Extended Radionuclide Urography (ERU) it is possible to distinguish between obstructive and dilated non obstructive hydronephrosis analysing activity time curves before and after furosemide injection. Furthermore, the miction part of the study can detect a vesicoureteral reflux without catheterisation. The method is non-invasive, saving radiation and costs and suitable for follow-up after surgical correction

  17. Renal transitional cell carcinoma: a sonographic and radiological correlation

    International Nuclear Information System (INIS)

    Prando, A.; Marins, J.L.C.; Prando, D.; Pereira, R.M.

    1984-01-01

    A sonographic study was performed on nine patients with renal transitional cell carcinoma and the findings correlated with those of excretory urography, retrograde and/or antegrade pyelography. In six patients the correct diagnosis was considered mainly by the radiological features. In the remaining three patients, due to its unusual manifestations, this diagnosis was accomplished only by sonography. A small echogenic mass at the peryphery of a chronic hydronephrotic kidney, a huge complex mass due to a multiple arborescent papilary tumor and a demonstration of a mass in a presumptive renal pelvic inflammatory disease, respectively, represented these uncommon aspects. The spectrum of features of this entity and the related differential diagnosis are also presented. (Author) [pt

  18. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  19. Functional MR urography in infants and children. Indications, techniques and requirements; Funktionelle MR-Urografie (fMRU) bei Kindern und Jugendlichen. Indikationen, Techniken und Anforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Martin; Mentzel, Hans-Joachim [Universitaetsklinikum Jena (Germany). Sektion Paediatrische Radiologie; Darge, Kassa [Children' s Hospital, Philadelphia, PA (United States). Section ' ' Body Imaging' ' ; John, Ulrike [Universitaetsklinikum Jena (Germany). Sektion Paediatrische Nephrologie

    2013-03-15

    Congenital anomalies of the kidney and urinary tract (CAKUT) need to be diagnosed correctly in early life in order to avoid the need for dialysis and renal transplantation. Traditionally, X-ray, fluoroscopy, computed tomography, and ultrasonography are the imaging methods to assess kidneys and the urinary tract. In infants and children, however, ultrasonography is the imaging method of first choice. In order to analyse the renal, to be more precise, the split renal function, MR urography has the potential for giving that information. More easily, information on morphology and dynamics of urinary flow in the upper renal tract can be obtained, too. Up to now, there is no commercial solution for obtaining split renal function with MR machines, however, two freeware solutions exist (''CHOP-fMRU'' and ''MR Urography''), that fill the gap. This article gives detailed information on patient selection, patient preparation, dedicated MR sequence technique, moreover discusses installation, use, and interpretation of the functional part using the ''CHOP-fMRU'' software. (orig.)

  20. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  1. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  2. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  3. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  4. Effect of mammals’ excretory function on aspartate aminotransferase activity in Glechoma hederacea leaves in conditions of Cd pollution

    Directory of Open Access Journals (Sweden)

    O. M. Vasilyuk

    2014-07-01

    Full Text Available The paper includes analysis of research of Cd impact on the activity of the enzyme of aspartate aminotransferase (AST nitrogen metabolism and the content of water-soluble protein fraction (albumin in Glechoma hederacea L. leaves, which dominated in the research area (in natural floodplain oak forest with Stellaria holostea L.. Cd was introduced in the form of salts of Cd(NO32 in the range of concentrations of: 0.25, 1.25, 2.5 g/m2, equivalent to the inclusion of Cd in 1, 5, 10 doses of MAC. Increase (P < 0.05 in the activity of AST 2.6–3.0 times (with adding Cd salts at a dose of 1 and 5 МAС and albumin content by 37% (with adding Cd salts at a dose of 10 МAС compared to control (the area without Cd pollution and excretory activity of mammals was shown. Using of excreta of some representatives of mammals (for example, Capreolus capreolus L. contributed to reduction of Cd toxic effects and restoring of the functional metabolic activity of AST by 23% (with Cd 1 МAС and by 34% (Cd 5 МAС. It is the evidence of protective function of mammals and their normalization effect at the above concentrations of Cd. Whereas the adding of Cd salts at a dose of 10 МAС led to 3 times’ inhibition of AST activity, the toxic effect of metal by excretory function of mammals was not reduced. Observations revealed the albumin content normalization by 22% in the presence of Cd 1MAC respectively (with the introduction of C. capreolus excreta and to the control level (the area without Cd pollution and excretory activity of mammals with the excreta of Sus scrofa L. in the setting of Cd 10 MAC. It proves the need to use the different mammal species for integrated and comprehensive normalization of ecosystems under conditions of uncontrolled anthropogenic pollution.

  5. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  6. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  7. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  8. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  9. In vivo thermoluminescent dosimetry in studies of helicoid computed tomography and excretory urogram

    International Nuclear Information System (INIS)

    Cruz C, D.; Azorin N, J.; Saucedo A, V.M.; Barajas O, J.L.

    2005-01-01

    The dosimetry is the field of measurement of the ionizing radiations. It final objective is to determine the 'absorbed dose' for people. The dosimetry is vital in the radiotherapy, the radiological protection and the treatment technologies by irradiation. Presently work, we develop 'In vivo' dosimetry, in exposed patients to studies of helical computed tomography and excretory urogram. The dosimetry 'in vivo' was carried out in 20 patients selected aleatorily, for each medical study. The absorbed dose was measured in points of interest located in crystalline, thyroid, chest and abdomen of each patient, by means of thermoluminescent dosemeters (TLD) LiF: Mg,Cu,P + Ptfe of national fabrication. Also it was quantified the dose in the working area. (Author)

  10. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  11. On the structure of fish gill, with special reference to its absorptive and excretory function

    International Nuclear Information System (INIS)

    Oguri, Mikio

    1981-01-01

    The gill of fish is not only the respiratory organ, but also the absorptive and excretory one of various substances, such as pesticides, anesthetics and minerals including radionuclides. Branchial absorption of Ca, Cr, Zn, Sr and Hg, and dieldrin (a pesticide) has been demonstrated by the gill-perfusion experiments using eel and rainbow trout. Also, branchial excretion of Cl, Ca and Sr has been ascertained by the same method using eel. Therefore, the gill is an important organ in relation to the accumulation and metabolism of radionuclides in fishes. Compared with the kidney, another excretory organ in fish, the structure of fish gill is rather simple. Histologically, the gill lamella, main functional portion of gill, is enveloped with simple squamous epithelium on each side. Between these two thin layers, pilaster cells and lacuna of branchial capillary are recognized as tissue components. In the gills of marine fishes, well-developed salt-secreting cells are detectable at the basal area of gill lamella. The cytoplasm of these cells are acidophilic and abundant in mitochondria and tubular endoplasmic reticulum. The cells are also called chloride cells and said to be involved in the extra-renal excretion of Na and Cl took in by marine fishes. The important problem is whether the salt-secreting cells in marine fishes are also concerned with the branchial excretion of another minerals such as Ca, Sr, I and so on, or these minerals are excreted across the ordinal epithelial cells of gill lamella. To elucidate this, detailed investigatios are awaited with interest. (author)

  12. Diagnostic potential of low molecular weight excretory secretory proteins of Paramphistomum epiclitum for caprine amphistomosis.

    Science.gov (United States)

    Jaiswal, Amit Kumar; Shanker, Daya; Sudan, Vikrant; Singh, Amit

    2018-06-15

    In the present study, the 75% alcoholic fractionation of excretory-secretory (ES) antigen isolated from 200 to 300 live P. epiclitum was assessed for its diagnostic potential for the detection of caprine amphistomosis by using antibody detection enzyme immunoassay. Prior to enzyme immunoassay, 75% alcoholic fractionation of excretory-secretory (ES) antigen was subjected to SDS- PAGE and western blot analysis for the presence of immunoreactive polypeptides. SDS-PAGE analysis of ES antigen resolved a total 7 polypeptides bands of size 56, 27, 25, 22.5, 12, 11 and 10 kDa. Western blot analysis revealed only two immunoreactive polypeptides (11 kDa and 12 kDa) when polypeptides resolved in SDS-PAGE were probed with known positive pooled serum. None of the polypeptides showed reactions with pooled known negative serum. The working dilutions of antigen, sera and conjugates were determined by checkerboard titration for employing ELISA and cut-off O.D. was calculated 0.616 by using the mean absorbance value of 11 negative kid sera. The sensitivity and specificity of ELISA was found to be 100% and 86.76%, respectively. As per kappa value estimation, the strength of agreement was found to be good. Antibodies to 75% alcoholic fractionation of ES antigen was detected in 20% goats (n = 160) of either sex, although faecal examination detected 10.6% goats to be infected with amphistomosis. The study confirmed that 75% alcoholic fractionation of ES antigen of P. epiclitum based ELISA had good value for serodiagnosis of caprine amphistomosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. The connection of hydronephrosis and microcirculation deterioration

    Directory of Open Access Journals (Sweden)

    Vorobets Dmytro

    2016-09-01

    Full Text Available In this study, we have analyzed the influence of hydronephrosis upon the microcirculation system, in situations of pyeloureteral junction obstruction. Herein, bulbar conjunctiva has been chosen as the object of this biomicroscopic study because of its simplicity and the method availability in clinic practice. In fulfilling this work, we ascertained the connections between extravascular, intravascular, vascular and general conjunctival indices of the patients before radical and paliatic correction of the pyeloureteral junction obstruction (i.e. by open and laparoscopic pyeloplasty, endopyelotomy, laser resection and balloon dilatation. We concluded that, apart from the proved deterioration of kidney function, systemic deteriorations of microcirculation may be observed in situations of clinically marked hydronephrosis, according to the results of radioisotope renography and excretory urography.

  14. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  15. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  16. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  17. Role of magnetic resonance urography in pediatric renal fusion anomalies

    International Nuclear Information System (INIS)

    Chan, Sherwin S.; Ntoulia, Aikaterini; Khrichenko, Dmitry; Back, Susan J.; Darge, Kassa; Tasian, Gregory E.; Dillman, Jonathan R.

    2017-01-01

    Renal fusion is on a spectrum of congenital abnormalities that occur due to disruption of the migration process of the embryonic kidneys from the pelvis to the retroperitoneal renal fossae. Clinically, renal fusion anomalies are often found incidentally and associated with increased risk for complications, such as urinary tract obstruction, infection and urolithiasis. These anomalies are most commonly imaged using ultrasound for anatomical definition and less frequently using renal scintigraphy to quantify differential renal function and assess urinary tract drainage. Functional magnetic resonance urography (fMRU) is an advanced imaging technique that combines the excellent soft-tissue contrast of conventional magnetic resonance (MR) images with the quantitative assessment based on contrast medium uptake and excretion kinetics to provide information on renal function and drainage. fMRU has been shown to be clinically useful in evaluating a number of urological conditions. A highly sensitive and radiation-free imaging modality, fMRU can provide detailed morphological and functional information that can facilitate conservative and/or surgical management of children with renal fusion anomalies. This paper reviews the embryological basis of the different types of renal fusion anomalies, their imaging appearances at fMRU, complications associated with fusion anomalies, and the important role of fMRU in diagnosing and managing children with these anomalies. (orig.)

  18. Role of magnetic resonance urography in pediatric renal fusion anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Sherwin S. [Children' s Mercy Hospital, Department of Radiology, Kansas City, MO (United States); Ntoulia, Aikaterini; Khrichenko, Dmitry [The Children' s Hospital of Philadelphia, Division of Body Imaging, Department of Radiology, Philadelphia, PA (United States); Back, Susan J.; Darge, Kassa [The Children' s Hospital of Philadelphia, Division of Body Imaging, Department of Radiology, Philadelphia, PA (United States); University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA (United States); Tasian, Gregory E. [University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA (United States); The Children' s Hospital of Philadelphia, Division of Urology, Department of Surgery, Philadelphia, PA (United States); Dillman, Jonathan R. [Cincinnati Children' s Hospital Medical Center, Division of Thoracoabdominal Imaging, Department of Radiology, Cincinnati, OH (United States)

    2017-12-15

    Renal fusion is on a spectrum of congenital abnormalities that occur due to disruption of the migration process of the embryonic kidneys from the pelvis to the retroperitoneal renal fossae. Clinically, renal fusion anomalies are often found incidentally and associated with increased risk for complications, such as urinary tract obstruction, infection and urolithiasis. These anomalies are most commonly imaged using ultrasound for anatomical definition and less frequently using renal scintigraphy to quantify differential renal function and assess urinary tract drainage. Functional magnetic resonance urography (fMRU) is an advanced imaging technique that combines the excellent soft-tissue contrast of conventional magnetic resonance (MR) images with the quantitative assessment based on contrast medium uptake and excretion kinetics to provide information on renal function and drainage. fMRU has been shown to be clinically useful in evaluating a number of urological conditions. A highly sensitive and radiation-free imaging modality, fMRU can provide detailed morphological and functional information that can facilitate conservative and/or surgical management of children with renal fusion anomalies. This paper reviews the embryological basis of the different types of renal fusion anomalies, their imaging appearances at fMRU, complications associated with fusion anomalies, and the important role of fMRU in diagnosing and managing children with these anomalies. (orig.)

  19. Distal ureteral calculi: the usefulness of transrectal ultrasound and comparison with intravenous urography

    International Nuclear Information System (INIS)

    Choi, Moon Hae; Yoon, Dae Young; Shim, Joo Eun; Kim, Ho Chul; Yi, Jeong Geun; Choi, Chul Sun; Bae, Sang Hoon; Kim, Ha Young

    1996-01-01

    To determine the usefulness of transrectal ultrasound (TRUS) and to compare TRUS with intravenous urography (IVU) in the evaluation of distal ureteral calculi. TRUS and IVU were performed in 24 patients with distal ureteral calculi. Using TRUS, we evaluated the presence and size of calculus, type of ureteral jet at the affected site and diameter of ureter proximal to calculus, and using IVU evaluated the presence and size of calculus, degree of ureteral obstruction, and degree of hydroureter. TRUS and IVU findings, were compared. In each patient, TRUS detected calculus of the distal ureter;in only 18 cases (75%), were the calculi demonstrated with IVU. In 18 cases where calculi were detected by both modalities, average calculus size was 4.5x3.0mm (longest and shortest dimensions) by IVU, and 6.1x3.7mm by TRUS. Between TRUS and IVU(p 0.05). TRUS appears to be a useful adjunctive method for the evaluation of distal ureteral calculus

  20. Is there need for both intravenous urography and voiding cystography in the evaluation of children with recurrent urinary tract infections?

    DEFF Research Database (Denmark)

    Nielsen, K K; Qvist, N; Jensen, K M

    1986-01-01

    In a prospective study 33 children (aged 6-14 years) consecutively referred for recurrent urinary tract infections (RUTI), underwent intravenous urography (IVU) as well as voiding cystography (VC). Seven children had unilateral and two children had bilateral renal scarring, while ten children had...... and the current theories on the significance of patient age and grade of VUR, we conclude that in case of a normal IVU in children with RUTI and age of at least 6 years, there is no reason to supplement the pre-treatment evaluation with VC....

  1. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  2. UNDESIRED REACTIONS AT THE UROGRAPHY IN THE CORRELATION OF THE IODIC AND THE NON-TODIC CONTRAST MEDIA

    Directory of Open Access Journals (Sweden)

    Rade R. Babić

    2000-07-01

    Full Text Available The paper analyzes the undesired reactions at 6053 urographies (IVU in thecorrelation of the iodic and the non-iodic contrast media (ICM.Depending on the allergological status the ICM (iodic or non-iodic is chosenfor the sake of carrying out an urographic examination as well as the necessarypremedication measures.The undesired reactions to the TCM are registered in 4,87% (1:20 TVU,namely in 5,6% (1:17 TVU to the iodic and in 2,39% (1:41 IVU to the non-iodicICM.At the intravenous application of the iodic ICM at the IVU the undesiredreactions are registered for2,4 times more often than at the application of the non-iodicICM.

  3. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  4. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  5. Imaging of transitional cell carcinomas of the urinary tracts

    International Nuclear Information System (INIS)

    Ozmen, M.

    2012-01-01

    Full text: Transitional cell carcinoma (TCC) is the most common urothelial neoplasm to involve the upper urinary tract and bladder. Prognosis significantly worsens with deeper invasion. The role of imaging is to detect the tiniest urothelial neoplasms while still potentially resectable and curable. In case of advance disease, imaging should identify the extent of disease. Intravenous or retrograde urography, ultrasonography, computed tomography or magnetic resonance imaging have been used for diagnosis of TCC. The diagnostic performances of these imaging modalities differ from each other. A recent review regarding imaging of TCC by Razavi et al states that the retrieved sensitivity/specificity for the detection of TCC of upper urinary tract for CT urography (CTU), MR urography, excretory urography, and retrograde urography were 96%/99%, 69%/97%, 80%/81%, and 96%/96%, respectively. For detecting bladder cancer, the retrieved sensitivity/specificity for CT cystography, MR cystography, and ultrasonography were 94%/98%, 91%/95%, and 78%/96%, respectively. They conclude that CT urography is the best imaging technique for confirming or excluding malignancy in the upper urinary tract, whereas CT cystography has the best diagnostic performance for diagnosing bladder cancer. While cystoscopy is still considered by most to be the gold-standard for evaluation of the urinary bladder, CTU is playing an increasing role in the detection of urinary bladder urothelial neoplasms. As with the upper urinary tract, bladder urothelial neoplasms typically present as a filling defect, a focal mass, or an area of abnormal focal wall thickening. Magnetic resonance imaging is superior for evaluation of the depth of tumour invasion into the bladder wall, but this knowledge may not ultimately affect treatment as feasibility for radical cystectomy depends on staging by a combination of clinical, histopathological and imaging findings. Radical cystectomy may include resection of adjacent organs

  6. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  7. Multi-slice CT urography after diuretic injection: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Wildberger, J.E.; Schmitz-Rode, T.; Guenther, R.W. [Technische Univ. Aachen (Germany). Dept. of Diagnostic Radiology; Borchers, H. [Technische Univ. Aachen (Germany). Dept. of Urology

    2001-03-01

    Purpose: To investigate the feasibility of CT urography (CTU) using a multi-slice (MS) scanner and to find out whether a low-dose diuretic injection is advantageous for the opacification of the urinary tract. Methods: MS-CTU was performed in 21 patients with urologic diseases. In 5/21 patients, 250 ml of physiologic saline solution were injected. In 16/21 patients, 10 mg of furosemide were injected 3-5 min before contrast material administration. A 4x2.5 mm collimation with a pitch of 1.25 and a tube curent of 100-150 mA were used. Scan time was 12-16 sec. 3 mm thin axial images with an overlap of 67% were reconstructed. Multiplanar maximum intensity projection (MIP) images were postprocessed to obtain urographic views. Bone structures were eliminated using the volume-of-interest method. Results: Furosemide-enhanced MS-CTU achieved either near complete or complete opacification in 30/32 (94%) ureters and in 32/32 (100%) pelvicaliceal systems up to a serum creatinine of 150 {mu}mol/l. In our series, only one CTU scan per patient was needed to obtain a diagnostic urogram after 10 min of contrast material injection. Ureteral compression was not necessary. When physiologic saline solution was used instead of furosemide, the radiopacity inside the enhanced pelvicalices was 4-5 times higher and more inhomogeneous. Diuretic-enhanced MS-CTU was more accurate in the depiction of pelvicaliceal details. In combination with furosemide, calculi were well identified inside the opacified urine and were safely differentiated from phleboliths. Postprocessing times of up to 20 minutes were problematic as were contrast-enhanced superimposing bowel loops on MIP images. Conclusion: Preliminary results demonstrate a good feasibility of furosemide-enhanced MS-CTU for obtaining detailed visualization of the entire upper urinary tract. (orig.) [German] Ziel: Untersuchung zur Durchfuehrbarkeit der CT Urographie (CTU) mit einem Multidetektor(MD)-Computertomographen und ob eine

  8. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  9. Incontinence due to an infrasphincteric ectopic ureter: why the delay in diagnosis and what the radiologist can do about it

    Energy Technology Data Exchange (ETDEWEB)

    Carrico, C.; Lebowitz, R.L. [Children`s Hospital Medical Center, Boston, MA (United States). Dept. of Radiology

    1998-12-01

    Purpose. To determine (1) the reasons for the frequently long delay in the diagnosis of an infrasphincteric ectopic ureter in girls, and (2) what role the radiologist can play in decreasing the delay. Materials and methods. Twelve girls were referred to our hospital from June 1994 until April 1997 for evaluation of constant urinary dribbling and/or vaginal discharge. Available imaging studies, radiology reports, and clinic notes were reviewed. Results. Mean age at the time of diagnosis was 6 years 7 months (range 2 years 10 months to 11 years 11 months). Mean delay until diagnosis after presentation was 2 years 5 months. Excluding the one girl whose ectopic ureter was diagnosed while she was still in diapers, mean age at the time of the first parental ``complaint`` was 4 years 9 months. The significance of the classic history of constant urinary dribbling was not recognized by physicians in 7 girls for 4 months to 7 years 10 months after presentation. Physical exam was not meticulously performed, as the ectopic orifice was visible in 8 of 12 girls. Imaging studies were ineffectively utilized: no imaging was done (for 2 years in 2 girls), inappropriate studies were done (ultrasound and voiding cystourethrography) and were misleading, studies were called normal when they were not (ultrasound and excretory urography), or perinatal imaging led to the incorrect assumption of a congenitally absent kidney in one girl and a multicystic dysplastic kidney in another. Excretory urography (EU) was diagnostic in all 10 girls with a duplex kidney, and computed tomography (CT) was supportive in 2 with a dysplastic kidney. CT was an adjunct in 3 girls; a Tc-99m-dimercaptosuccinic acid (DMSA) scan was needed in 2. Conclusion. The classic history of constant urinary dribbling in a successfully toilet-trained girl should immediately lead to an imaging search for the portion of kidney (or entire kidney) drained by an infrasphincteric ectopic ureter. EU should usually be the first

  10. Incontinence due to an infrasphincteric ectopic ureter: why the delay in diagnosis and what the radiologist can do about it

    International Nuclear Information System (INIS)

    Carrico, C.; Lebowitz, R.L.

    1998-01-01

    Purpose. To determine (1) the reasons for the frequently long delay in the diagnosis of an infrasphincteric ectopic ureter in girls, and (2) what role the radiologist can play in decreasing the delay. Materials and methods. Twelve girls were referred to our hospital from June 1994 until April 1997 for evaluation of constant urinary dribbling and/or vaginal discharge. Available imaging studies, radiology reports, and clinic notes were reviewed. Results. Mean age at the time of diagnosis was 6 years 7 months (range 2 years 10 months to 11 years 11 months). Mean delay until diagnosis after presentation was 2 years 5 months. Excluding the one girl whose ectopic ureter was diagnosed while she was still in diapers, mean age at the time of the first parental ''complaint'' was 4 years 9 months. The significance of the classic history of constant urinary dribbling was not recognized by physicians in 7 girls for 4 months to 7 years 10 months after presentation. Physical exam was not meticulously performed, as the ectopic orifice was visible in 8 of 12 girls. Imaging studies were ineffectively utilized: no imaging was done (for 2 years in 2 girls), inappropriate studies were done (ultrasound and voiding cystourethrography) and were misleading, studies were called normal when they were not (ultrasound and excretory urography), or perinatal imaging led to the incorrect assumption of a congenitally absent kidney in one girl and a multicystic dysplastic kidney in another. Excretory urography (EU) was diagnostic in all 10 girls with a duplex kidney, and computed tomography (CT) was supportive in 2 with a dysplastic kidney. CT was an adjunct in 3 girls; a Tc-99m-dimercaptosuccinic acid (DMSA) scan was needed in 2. Conclusion. The classic history of constant urinary dribbling in a successfully toilet-trained girl should immediately lead to an imaging search for the portion of kidney (or entire kidney) drained by an infrasphincteric ectopic ureter. EU should usually be the first

  11. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  12. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  13. Clinical comparison of high-speed rare-earth screen and par-speed screen for diagnostic efficacy and radiation dosage

    International Nuclear Information System (INIS)

    Robinson, T.; Becker, J.A.; Olson, A.P.

    1982-01-01

    One hundred patients underwent excretory urography and a comparison was made of ten-minute, well-collimated images that were obtained with both par-speed and rare-earth screens, the latter being 6.5 times faster than the par-speed calcium tungstate screens. Radiation dose was greatly reduced with the rare-earth screens. There were fewer inferior examinations, even though fine detail was imaged poorly, and there was a slightly increased quantum mottle, which was only a minor problem at this low 65 kVp. Since quantum mottle increases with kVp, however, our results are not applicable to higher kVp examinations. Despite reduced detail and increased mottle, the overall image quality obtained with the rare-earth screen was superior to the image quality obtained with the par-speed screen

  14. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  15. Effect of Fasciola gigantica excretory secretory antigen on rat hematological indices

    Science.gov (United States)

    Ganga, G.; Sharma, R. L.

    2006-01-01

    The present study was undertaken to investigate the effect of Fasciola gigantica excretory secretory antigen (Fg-ESA) on rat hematological indices. Fg-ESA was prepared by keeping thoroughly washed 40 F. gigantica flukes in 100 ml phosphate buffer saline (PBS) for 2 h at 37℃, and centrifuging the supernatant at 12,000 g at 4℃ for 30 min. The protein content of Fg-ESA was adjusted to 1.8 mg/ml. The rats were randomly divided into two groups of six rats each. Rats in group A received 0.5 ml of Fg-ESA intraperitoneally (i.p.) for 7 days, whereas control rats in group B received 0.5 ml of PBS i.p. for 7 days. Hemograms of both groups were studied initially and on days 0, 2, 4, 14 and 21 after the final injection of Fg-ESA or PBS. Progressive and significant (p 0.05) changes in the values of mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, or mean corpuscular volume in group A. Thus, we conclude that Fg-ESA induces normocytic normochromic anemia in rats. PMID:16645335

  16. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  17. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  18. The roles of supernatant of macrophage treated by excretory-secretory products from muscle larvae of Trichinella spiralis on the differentiation of C2C12 myoblasts

    Science.gov (United States)

    The excretory-secretory products (ESPs) released by the muscle-larvae (ML) stage of Trichinella spiralis have been suggested to be involved in nurse cell formation. However, the molecular mechanisms by which ML-ESPs modulate nurse cell formation remain unclear. Macrophages exert either beneficial or...

  19. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  20. Radiological findings after endoscopic incision of ureterocele

    International Nuclear Information System (INIS)

    Cheon, Jung Eun; Kim, In One; Seok, Eul Hye; Cha, Joo Hee; Choi, Gook Myung; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Kwang Myung; Choi, Hwang; Cheon, Jung Eun; Seok, Eul Hye; Cha, Joo Hee; Choi, Guk Myung

    2001-01-01

    Endoscopic incision of ureterocele is considered a simple and safe method for decompression of urinary tract obstruction above ureterocele. The purpose of this study was to evaluate the radiological findings after endoscopic incision of ureterocele. We retrospectively reviewed the radiological findings (ultrasonography (US), intravenous urography, and voiding cystourethrography(VCU)) in 16 patients with ureterocele who underwent endoscopic incision (mean age at surgery, 15 months; M:F 3:13; 18 ureteroceles). According to the postoperative results, treatment was classified as successful when medical treatment was still required, and second operation when additional surgical treatment was required. Postoperative US (n=10) showed that in all patients, urinary tract obstruction was relieved: the kidney parenchima was thicker and the ureterocele was smaller. Intravenous urography (n=8), demonstrated that in all patients, urinary tract obstruction and the excretory function of the kidney had improved. Postoperative VCU indicated that in 92% of patients (12 of 13), endoscopic incision of the ureterocele led to vesicoureteral reflux(VUR). Of these twelve, seven (58%) showed VUR of more than grade 3, while newly developed VUR was seen in five of eight patients (63%) who had preoperative VCU. Surgery was successful in four patients (25%), partially successful in three (19%), and a second operation-on account of recurrent urinary tract infection and VUR of more than grase 3 during the follow-up period-was required by nine (56%). Although endoscopic incision of a ureterocele is a useful way of relieving urinary tract obstruction, an ensuing complication may be VUR. Postoperative US and intravenous urography should be used to evaluate parenchymal change in the kidney and improvement of uronary tract obstructon, while to assess the extend of VUR during the follow-up period , postoperative VCU is required

  1. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  2. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  3. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  4. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  5. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  6. Comparative assay of glutathione S-transferase (GSTs) activity of excretory-secretory materials and somatic extract of Fasciola spp parasites.

    Science.gov (United States)

    Alirahmi, Heshmatollah; Farahnak, Ali; Golmohamadi, Taghi; Esharghian, Mohammad Reza

    2010-01-01

    Fascioliasis is a worldwide parasitic disease in human and domestic animals. The causative agents of fascioliasis are Fasciola hepatica and Fasciola gigantica. In the recent years, fasciola resistance to drugs has been reported in the many of publications. Fasciola spp has detoxification system including GST enzyme which may be responsible for its resistance. Therefore , the aim of the study was to assay of GST enzyme activity in fasciola parasites. Fasciola gigantica and Fasciola hepatica helminths were collected from abattoir as a live and cultured in buffer media for 4 h at 37 °C. Excretory-Secretory products were collected and stored in -80◦C. F. gigantica and Fasciola hepatica were homogenized with homogenizing buffer in a glass homogenizer to prepare of somatic extract. Suspension was then centrifuged and supernatant was stored at -80°C. In order to assay the enzyme activity, excretory-secretory and somatic extracts in the form of cocktails (potassium phosphate buffer, reduced glutathione and 1-chloro-2,4-dinitrobenzene substrates) were prepared and their absorbance recorded for 5 minutes at 340 nm. The total and specific GST activity of F. gigantica somatic and ES products were obtained as 2916.00, 272.01 micromole/minute and 1.33, 1.70 micromole/minute/mg protein, respectively. Fasciola hepatica also showed 2705.00, 276.86 micromole/minute and 1.33, 1.52 micromole/minute/mg protein, respectively. These results are important for analysis of parasite survival / resistance to drugs which use for treatment of fascioliasis.

  7. Intraindividual comparison of image quality in MR urography at 1.5 and 3 Tesla in an animal model

    Energy Technology Data Exchange (ETDEWEB)

    Regier, M.; Adam, G.; Kemper, J. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Nolte-Ernsting, C. [Klinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2008-10-15

    Purpose: experimental evaluation of image quality of the upper urinary tract in MR urography (MRU) at 1.5 and 3 Tesla in a porcine model. Materials and methods: in this study four healthy domestic pigs, weighing between 71 and 80 kg (mean 73.6 kg), were examined with a standard T 1w 3D-GRE and a high-resolution (HR) T 1w 3D-GRE sequence at 1.5 and 3 Tesla. Additionally, at 3 Tesla both sequences were performed with parallel imaging (SENSE factor 2). The MR urographic scans were performed after intravenous injection of gadolinium-DTPA (0.1 mmol/kg body weight (bw)) and low-dose furosemide (0.1 mg/kg bw). Image evaluation was performed by two independent radiologists blinded to sequence parameters and field strength. Image analysis included grading of image quality of the segmented collecting system based on a five-point grading scale regarding anatomical depiction and artifacts observed (1: the majority of the segment (> 50%) was not depicted or was obscured by major artifacts; 5: the segment was visualized without artifacts and had sharply defined borders). Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined. Statistical analysis included {kappa}-statistics, Wilcoxon and paired student t-test. Results: the mean scores for MR urographies at 1.5 Tesla were 2.83 for the 3D-GRE and 3.48 for the HR 3D-GRE sequence. Significantly higher values were determined using the corresponding sequences at 3 Tesla, averaging 3.19 for the 3D-GRE (p = 0.047) and 3.92 for the HR 3D-GRE (p = 0.023) sequence. Delineation of the pelvicaliceal system was rated significantly higher at 3 Tesla compared to 1.5 Tesla (3D-GRE: p = 0.015; HR 3D-GRE: p = 0.006). At 3 Tesla the mean SNR and CNR were significantly higher (p < 0.05). A {kappa} of 0.67 indicated good interobserver agreement. (orig.)

  8. Intraindividual comparison of image quality in MR urography at 1.5 and 3 Tesla in an animal model

    International Nuclear Information System (INIS)

    Regier, M.; Adam, G.; Kemper, J.; Nolte-Ernsting, C.

    2008-01-01

    Purpose: experimental evaluation of image quality of the upper urinary tract in MR urography (MRU) at 1.5 and 3 Tesla in a porcine model. Materials and methods: in this study four healthy domestic pigs, weighing between 71 and 80 kg (mean 73.6 kg), were examined with a standard T 1w 3D-GRE and a high-resolution (HR) T 1w 3D-GRE sequence at 1.5 and 3 Tesla. Additionally, at 3 Tesla both sequences were performed with parallel imaging (SENSE factor 2). The MR urographic scans were performed after intravenous injection of gadolinium-DTPA (0.1 mmol/kg body weight (bw)) and low-dose furosemide (0.1 mg/kg bw). Image evaluation was performed by two independent radiologists blinded to sequence parameters and field strength. Image analysis included grading of image quality of the segmented collecting system based on a five-point grading scale regarding anatomical depiction and artifacts observed (1: the majority of the segment (> 50%) was not depicted or was obscured by major artifacts; 5: the segment was visualized without artifacts and had sharply defined borders). Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined. Statistical analysis included κ-statistics, Wilcoxon and paired student t-test. Results: the mean scores for MR urographies at 1.5 Tesla were 2.83 for the 3D-GRE and 3.48 for the HR 3D-GRE sequence. Significantly higher values were determined using the corresponding sequences at 3 Tesla, averaging 3.19 for the 3D-GRE (p 0.047) and 3.92 for the HR 3D-GRE (p = 0.023) sequence. Delineation of the pelvicaliceal system was rated significantly higher at 3 Tesla compared to 1.5 Tesla (3D-GRE: p = 0.015; HR 3D-GRE: p = 0.006). At 3 Tesla the mean SNR and CNR were significantly higher (p < 0.05). A κ of 0.67 indicated good interobserver agreement. (orig.)

  9. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  10. Quantitative parameters of seminiferous epithelium in secretory and excretory oligoazoospermia.

    Science.gov (United States)

    Francavilla, S; Martini, M; Properzi, G; Cordeschi, G

    1990-01-01

    Testicular biopsy specimens from infertile men (sperm count, less than 10(6)/ml) were evaluated on 1-micron thick sections, and counts of stem cells and differentiated spermatogonia, primary spermatocytes, early and late spermatids, and Sertoli cells were compared to counts in six fertile men. Biopsy specimens were also compared for the appearance of seminiferous tubule wall, blood vessels, and interstitium. Infertile men were grouped according to the following diagnoses: hypospermatogenesis (n = 5), spermatocyte arrest of spermatogenesis (n = 5), and obstruction of the genital tract (n = 7). A low productivity of spermatogenesis in cases of hypospermatogenesis appeared to be due to an exaggerated degeneration of primary spermatocytes and to a yield of abnormal spermatids. A block of meiosis in spermatocyte arrest was associated with a degeneration of primary spermatocytes and with a reduced number of staminal spermatogonia. Abnormal spermiogenesis was observed in cases of obstruction of the genital tract and was associated with an increase in stem cell spermatogonia. A thickening of seminiferous tubule and blood vessel walls could be responsible for the limited functional capacity of Sertoli cells, causing altered spermiogenesis in cases of excretory azoospermia. A severe primitive failure of Sertoli cells in secretory oligoazoospermia could account for a deranged maturation and degeneration of premeiotic and postmeiotic germ cells.

  11. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  12. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  13. Re-Normalization Method of Doppler Lidar Signal for Error Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Park, Nakgyu; Baik, Sunghoon; Park, Seungkyu; Kim, Donglyul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Dukhyeon [Hanbat National Univ., Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, we presented a re-normalization method for the fluctuations of Doppler signals from the various noises mainly due to the frequency locking error for a Doppler lidar system. For the Doppler lidar system, we used an injection-seeded pulsed Nd:YAG laser as the transmitter and an iodine filter as the Doppler frequency discriminator. For the Doppler frequency shift measurement, the transmission ratio using the injection-seeded laser is locked to stabilize the frequency. If the frequency locking system is not perfect, the Doppler signal has some error due to the frequency locking error. The re-normalization process of the Doppler signals was performed to reduce this error using an additional laser beam to an Iodine cell. We confirmed that the renormalized Doppler signal shows the stable experimental data much more than that of the averaged Doppler signal using our calibration method, the reduced standard deviation was 4.838 Χ 10{sup -3}.

  14. Maximisation of the Doppler effect in thermal reactors

    International Nuclear Information System (INIS)

    Bende, E.E.

    1998-03-01

    Increase of the fuel temperature in a nuclear reactor leads, or can lead, to (1) A Doppler broadening of the resonances of the nuclides in the fuel; (2) An expansion of the fuel; and (3) A shift of the Maxwellian part of the spectrum to higher energies. These processes together introduce a certain amount of reactivity, which can be expressed in the so-called fuel temperature reactivity coefficient. The reactivity effect of the third process is very small, because the Maxwell spectrum is to a major extent determined by the moderator temperature. Moreover, the reactivity effect due to an expansion of the fuel is small too, for most thermal systems. When the second and third processes can be neglected, the fuel temperature reactivity effect is fully determined by the Doppler effect. The fuel temperature reactivity coefficient is then called the Doppler coefficient of reactivity. The Doppler broadening of the resonances causes an increase of resonance absorption, due to a decrease of self-shielding. The competition between resonance fission at the one hand and resonance capture at the other hand determines the sign and magnitude of the reactivity induced by an increase of the fuel temperature. In well-designed nuclear reactors the Doppler effect due to resonance capture by fertile nuclides exceeds the Doppler effect due to resonance fission, which implies that an increase of the fuel temperature causes a negative reactivity effect and a correspondingly negative Doppler coefficient. Since the Doppler effect is a prompt effect, occurring simultaneously with the dissipation of kinetic energy of the fission products into temperature, it is very important in the study of rapid power transients. In this report, the Doppler coefficient of reactivity is defined in chapter 2. Chapter 3 discusses the geometry of the unit-cell for which the calculations are performed and describes the fuel types that have been investigated. In chapter 4 the 'Doppler efficiency' is introduced and

  15. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Directory of Open Access Journals (Sweden)

    Lawrence H. Lin

    Full Text Available Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: “Gestational trophoblastic disease AND Ultrasonography, Doppler.” Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1 Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2 There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3 Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4 Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. CONCLUSION: Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  16. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Science.gov (United States)

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-12-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  17. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  18. Doppler speedometer for micro-organisms

    International Nuclear Information System (INIS)

    Penkov, F.; Tuleushev, A.; Lisitsyn, V.; Kim, S.; Tuleushev, Yu.

    1996-01-01

    Objective of Investigations: Development and creation of the Doppler speedometer for micro-organisms which allows to evaluate, in a real temporal scale, variations in the state of water suspension of micro-organisms under the effect of chemical, physical and other external actions. Statement of the Problem The main problem is absence of reliable, accessible for users and simple, in view of application, Doppler speedometers for micro-organisms. Nevertheless, correlation Doppler spectrometry in the regime of heterodyning the supporting and cell-scattered laser radiation is welt known. The main idea is that the correlation function of photo-current pulses bears an information on the averages over the assembly of cell velocities. For solving the biological problems, construction of auto-correlation function in the real-time regime with the delay time values comprising, function in the real-time regime with the delay time values comprising, nearly, 100 me (10 khz) or higher is needed. Computers of high class manage this problem using but the program software. Due to this, one can simplify applications of the proposed techniques provided he creates the Doppler speedometer for micro-organism on a base of the P entium . Expected Result Manufactured operable mock-up of the Doppler speedometer for micro-organisms in a form of the auxiliary computer block which allows to receive an information, in the real time scale, on the results of external effects of various nature on the cell assembly in transparent medium with a small volume of the studied cell suspension

  19. Transitional neonatal hydronephrosis: fact or fantasy

    International Nuclear Information System (INIS)

    Homsy, Y.L.; Williot, P.; Danais, S.

    1986-01-01

    Hydronephrosis secondary to an anomalous ureteropelvic junction was detected antenatally in more than 60 neonatal renal units Those 21 units that exhibited partial obstruction or dilatation without obstruction were selected for this study. They were assessed and followed by serial diuretic isotope renography (99mtechnetium-diethylenetriaminepentaacetic acid augmented with furosemide) and ultrasonography. Excretory urography was used selectively. Of the 17 renal units that could be assessed 88 per cent demonstrated labile ureteropelvic junctions. Indeed, in 3 to 6 months, when the definitive status seemed to be attained, 41 per cent (7 units) had deteriorated, 12 per cent (2 units) remained stable and 47 per cent (8 units) underwent spontaneous improvement. We recommend a 3 to 6-month observation period for patients with hydronephrosis secondary to ureteropelvic junction anomalies when definite obstruction cannot be confirmed by isotope renography

  20. Unilateral perinephric pseudocyst of undetermined origin in a dog

    International Nuclear Information System (INIS)

    Miles, K.G.; Jergens, A.E.

    1992-01-01

    Unilateral perinephric pseudocyst of undetermined origin was diagnosed in a 131/2 year old dog with a history of recurrent urinary tract infections. A presumptive diagnosis of pseudocyst was based on radiographic and sonographic findings. In survey radiographs, asymmetrical unilateral renomegaly was seen. The mass was anechoic. There was absence of opacification of the mass during excretory urography. A celiotomy was performed for removal of the perinephric mass, and histologic review of this structure confirmed it to be a pseudocyst. Perinephric accumulation of fluid is a rare condition in domestic animals. Seven examples of perinephric pseudocysts have been previously reported in the cat. Predominant clinical findings include progressive abdominal distension and nonspecific signs of renal disease. The presence of unilateral or bilateral renomegaly is a characteristic radiographic feature. This clinical report describes the first case of perinephric pseudocyst diagnosed in the dog

  1. Correlating intravenous radiographic contrast media reactions with the allergic profile

    International Nuclear Information System (INIS)

    Chua-Lim, A.; Enright, T.; Duda, E.; Lim, D.T.

    1987-01-01

    To determine the relevance of allergy as a predisposing factor in reactions to radiographic contrast media, the authors investigated the incidence of allergy among 100 randomly selected patients undergoing intravenous excretory urography and CT. The study population consisted of 50 reactors and 50 nonreactos to radiographic contrast media. All 100 subjects completed an allergy history, percutaneous allergy tests, and an in vitro specific IgE assay to common allergens. Thirty-four of 50 reactors had a positive allergy history, in contrast to 15 of 50 nonreactors (P < .001). Twenty-seven reactors had positive skin tests, in contrast to 12 of 50 nonreactors (P < .005). In vitro IgE assay results are pending. The results indicate that patients with positive histories or positive skin tests or both are at an increased risk for reactions to radiographic contrast media

  2. [X-ray evaluation of renal function in children with hydronephrosis as a criterion in the selection of therapeutic tactics].

    Science.gov (United States)

    Bosin, V Iu; Murvanidze, D D; Sturua, D G; Nabokov, A K; Soloshenko, V N

    1989-01-01

    The anatomic parameters of the kidneys and the rate of glomerular filtration were measured in 77 children with unilateral hydronephrosis and in 27 children with nonobstructive diseases of the urinary tract according to the clearance of an opaque medium during excretory urography. Alterations in the anatomic parameters of the kidneys in obstructive affection did not reflect the gravity of functional disorders. It has been established that there is a possibility of carrying out a separate assessment of filtration function of the hydronephrotic and contralateral kidneys. A new diagnostic criterion is offered, namely an index of relative clearance, which enables one to measure the degree of compensatory phenomena in the preserved glomeruli and the extent of sclerotic process. It has been demonstrated that accurate measurement of the functional parameters of the affected kidney should underlie the treatment choice in children with unilateral hydronephrosis.

  3. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    accurate measurement of aircraft location to resample the time signal to account for the compression and expansion of acoustic wavefronts. Correcting...AFRL-RH-WP-TR-2017-0043 DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS Frank Mobley, PhD 711 HPW/RHCB Wright-Patterson AFB OH...TITLE AND SUBTITLE DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  4. Calculation of the Doppler broadening function using Fourier analysis;Calculo da funcao de alargamento Doppler utilizando analise de Fourier

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da Cruz

    2010-07-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function {psi}(x,{zeta}) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for {psi}(x,{zeta}), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  5. Functional-anatomic evaluation of dilated uropathies in children using combined MR-nephrography and MR-urography compared to renal scintigraphy; Funktionell-anatomische Diagnostik dilatierter Uropathien bei Kindern mit kombinierter MR-Nephrographie und MR-Urographie im Vergleich zur renalen Isotopennephrographie

    Energy Technology Data Exchange (ETDEWEB)

    Reither, M. [Abt. fuer bildgebende Diagnostik am Kinderkrankenhaus Park Schoenfeld, Kassel (Germany); Tuerkay, S. [GE Medical Systems Deutschland GmbH, Solingen (Germany)

    2004-02-01

    Purpose: to evaluate MR-tomographic assessment of split renal function and degree of obstruction compared to diuretic renal scintigraphy, and pathoanatomic imaging of the urinary tract as all in one exam. Patients and methods: in a prospective study 62 children, aged 1 month to 9.5 years, mean 2.8 years, underwent diuretic renal scintigraphy and dynamic MR-nephrography at the same day except for 7 patients with a time interval of 1 day. In all patients we did T2w (water-technique) MR-urography additionally. Results: comparing spilt renal function we found a very close correlation in 54 out of 62 patients (correlation coefficient = 0.95). Due to technical failures 8 cases couldn't be calculated. Comparing degrees of obstruction there was an agreement in 57 out of 62 patients, 3 studies were gradually over-, 2 underestimated. All but one morphologic diagnoses in advance obtained by ultrasound and completed by other imaging modalities later on were confirmed MR-urographically. Though correctly imaged the functionless upper moiety in a renal duplication with ureterocele was misinterpreted at a first glance. (orig.) [German] Ziel: Es sollte geprueft werden, ob die Berechnung der seitengetrennten Nierenfunktion, die Bestimmung des Obstruktionsgrades und die pathoanatomische Darstellung des Harntraktes im Vergleich zur Diurese-Szintigraphie in einem Untersuchungsgang MR-tomographisch zuverlaessig moeglich ist. Patienten und Methode: In einer prospektiven Studie wurden bei 62 Kindern im Alter von 1 Monat bis 9,5 Jahren, Mittelwert 2,8 Jahre, ein Diurese-Szintigramm und eine dynamische MR-Nephrographie am gleichen Tag durchgefuehrt; lediglich bei 7 Patienten lag 1 Tag zwischen beiden Untersuchungen. Alle Patienten erhielten zusaetzlich eine T2w-MR-Urographie in ''Wasserbild''-Technik. Ergebnisse: Beim Vergleich der seitengetrennten Nierenfunktion fand sich eine sehr enge Korrelation bei 54 von insgesamt 62 Patienten (Korrelationskoeffizient = 0

  6. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  7. The phenomenon of Doppler

    International Nuclear Information System (INIS)

    Stoll, I.; Seidlerova, I.; Schwippel, J.; Poss, O.; Solc, M.

    1992-01-01

    The book is devoted to the life and work of Christian Doppler and particularly to his links to Prague and to the Slovak town of Banska Stiavnica. Many historical facts concerning Doppler's activities as well as the history of physics and astronomy are collected. Information is also presented about the Czech Technical University, the Society of Czechoslovak Mathematicians and Physicists, the Czechoslovak Astronomical Society, the Czechoslovak Spectroscopic Society and the Czechoslovak Society for the History of Science and Technology. The publication is amply supplemented with historical pictorial material (M.D.). 92 figs., 82 refs

  8. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  9. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  10. New Insights from Inside-Out Doppler Tomography

    Directory of Open Access Journals (Sweden)

    E. J. Kotze

    2015-02-01

    Full Text Available We present preliminary results from our investigation into using an “inside-out” velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  11. Measurement of ventricular function using Doppler ultrasound

    International Nuclear Information System (INIS)

    Teague, S.M.

    1986-01-01

    Doppler has wide application in the evaluation of valvular heart disease. The need to know ventricular function is a much more common reason for an echocardiographic evaluation. Interestingly, Doppler examinations can assess ventricular function from many perspectives. Description of ventricular function entails measurement of the timing, rate and volume of ventricular filling and ejection. Doppler ultrasound examination reveals all of these aspects of ventricular function noninvasively, simply, and without great expense or radiation exposure, as described in this chapter

  12. MP3 compression of Doppler ultrasound signals.

    Science.gov (United States)

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  13. Analysis of Doppler effect with JAERI-Fast set

    International Nuclear Information System (INIS)

    Takano, Hideki; Matsui, Yasushi.

    1977-07-01

    Temperature dependence of group cross sections in the JAERI-Fast set versions I, IR, II and IIR has been tested from the analysis of Doppler experiments performed with two different methods. One is Doppler reactivity measurement for the whole core of SEFOR assembly, and the other sample Doppler reactivity measurement for natural UO 2 in FCA assemblies V-1, V-2, VI-1 and VI-2, ZPR-6-7, ZPR-3-47, and ZPPR-2 and 3. Doppler effects were calculated with one- and two-dimensional diffusion 1-st order perturbation code DOPP2D. The results calculated with the JAERI-Fast set versions II and IIR are in good agreement with the experimental ones. In these calculation, resonance heterogeneity effect, stainless-stell buffer effect and plate heterogeneity effect are considered, and these effects contribute significantly to Doppler effect. (auth.)

  14. Comparative Assay of Glutathione S- Transferase (GSTs Activity of Excretory-Secretory Materials and Somatic Extract of Fasciola spp Parasites

    Directory of Open Access Journals (Sweden)

    Heshmatollah Alirahmi

    2010-12-01

    Full Text Available Fascioliasis is a worldwide parasitic disease in human and domestic animals. The causative agents of fascioliasis are Fasciola hepatica and Fasciola gigantica. In the recent years, fasciola resistance to drugs has been reported in the many of publications. Fasciola spp has detoxification system including GST enzyme which may be responsible for its resistance. Therefore , the aim of the study was to assay of GST enzyme activity in fasciola parasites. Fasciola gigantica and Fasciola hepatica helminths were collected from abattoir as a live and cultured in buffer media for 4 h at 37 °C. Excretory-Secretory products were collected and stored in -80◦C. F. gigantica and Fasciola hepatica were homogenized with homogenizing buffer in a glass homogenizer to prepare of somatic extract. Suspension was then centrifuged and supernatant was stored at -80°C. In order to assay the enzyme activity, excretory-secretory and somatic extracts in the form of cocktails (potassium phosphate buffer, reduced glutathione and 1-chloro-2,4-dinitrobenzene substrates were prepared and their absorbance recorded for 5 minutes at 340 nm. The total and specific GST activity of F. gigantica somatic and ES products were obtained as 2916.00, 272.01 micromole/minute and 1.33, 1.70 micromole/minute/mg protein, respectively. Fasciola hepatica also showed 2705.00, 276.86 micromole/minute and 1.33, 1.52 micromole/minute/mg protein, respectively. These results are important for analysis of parasite survival / resistance to drugs which use for treatment of fascioliasis.

  15. Comparative Assay of Glutathione S- Transferase (GSTs Activity of Excretory-Secretory Materials and Somatic Extract of Fasciola spp Parasites

    Directory of Open Access Journals (Sweden)

    Taghi Golmohamadi

    2010-11-01

    Full Text Available Fascioliasis is a worldwide parasitic disease in human and domestic animals. The causative agents of fascioliasis are Fasciola hepatica and Fasciola gigantica. In the recent years, fasciola resistance to drugs has been reported in the many of publications. Fasciola spp has detoxification system including GST enzyme which may be responsible for its resistance. Therefore , the aim of the study was to assay of GST enzyme activity in fasciola parasites. Fasciola gigantica and Fasciola hepatica helminths were collected from abattoir as a live and cultured in buffer media for 4 h at 37 °C. Excretory-Secretory products were collected and stored in -80◦C. F. gigantica and Fasciola hepatica were homogenized with homogenizing buffer in a glass homogenizer to prepare of somatic extract. Suspension was then centrifuged and supernatant was stored at -80°C. In order to assay the enzyme activity, excretory-secretory and somatic extracts in the form of cocktails (potassium phosphate buffer, reduced glutathione and 1-chloro-2,4-dinitrobenzene substrates were prepared and their absorbance recorded for 5 minutes at 340 nm. The total and specific GST activity of F. gigantica somatic and ES products were obtained as 2916.00, 272.01 micromole/minute and 1.33, 1.70 micromole/minute/mg protein, respectively. Fasciola hepatica also showed 2705.00, 276.86 micromole/minute and 1.33, 1.52 micromole/minute/mg protein, respectively. These results are important for analysis of parasite survival / resistance to drugs which use for treatment of fascioliasis.

  16. Computer-aided detection of bladder wall thickening in CT urography (CTU)

    Science.gov (United States)

    Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon Z.; Gordon, Marshall N.; Samala, Ravi K.

    2018-02-01

    We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). Bladder wall thickening is a manifestation of bladder cancer and its detection is more challenging than the detection of bladder masses. We first segmented the inner and outer bladder walls using our method that combined deep-learning convolutional neural network with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensity-projection-based method. The non-contrast region was smoothed and gray level threshold was applied to the contrast and non-contrast regions separately to extract the bladder wall and potential lesions. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify regions of wall thickening candidates. Volume-based features of the wall thickening candidates were analyzed with linear discriminant analysis (LDA) to differentiate bladder wall thickenings from false positives. A data set of 112 patients, 87 with wall thickening and 25 with normal bladders, was collected retrospectively with IRB approval, and split into independent training and test sets. Of the 57 training cases, 44 had bladder wall thickening and 13 were normal. Of the 55 test cases, 43 had wall thickening and 12 were normal. The LDA classifier was trained with the training set and evaluated with the test set. FROC analysis showed that the system achieved sensitivities of 93.2% and 88.4% for the training and test sets, respectively, at 0.5 FPs/case.

  17. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  18. Complex regression Doppler optical coherence tomography

    Science.gov (United States)

    Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2018-04-01

    We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.

  19. Cross-correlation Doppler global velocimetry (CC-DGV)

    Science.gov (United States)

    Cadel, Daniel R.; Lowe, K. Todd

    2015-08-01

    A flow velocimetry method, cross-correlation Doppler global velocimetry (CC-DGV), is presented as a robust, simplified, and high dynamic range implementation of the Doppler global/planar Doppler velocimetry technique. A sweep of several gigahertz of the vapor absorption spectrum is used for each velocity sample, with signals acquired from both Doppler-shifted scattered light within the flow and a non-Doppler shifted reference beam. Cross-correlation of these signals yields the Doppler shift between them, averaged over the duration of the scan. With presently available equipment, velocities from 0 ms-1 to over 3000 ms-1 can notionally be measured simultaneously, making the technique ideal for high speed flows. The processing routine is shown to be robust against large changes in the vapor pressure of the iodine cell, benefiting performance of the system in facilities where ambient conditions cannot be easily regulated. Validation of the system was performed with measurements of a model wind turbine blade boundary layer made in a 1.83 m by 1.83 m subsonic wind tunnel for which laser Doppler velocimetry (LDV) measurements were acquired alongside the CC-DGV results. CC-DGV uncertainties of ±1.30 ms-1, ±0.64 ms-1, and ±1.11 ms-1 were determined for the orthogonal stream-wise, transverse-horizontal, and transverse-vertical velocity components, and root-mean-square deviations of 2.77 ms-1 and 1.34 ms-1 from the LDV validation results were observed for Reynolds numbers of 1.5 million and 2 million, respectively. Volumetric mean velocity measurements are also presented for a supersonic jet, with velocity uncertainties of ±4.48 ms-1, ±16.93 ms-1, and ±0.50 ms-1 for the orthogonal components, and self-validation done by collapsing the data with a physical scaling.

  20. Editorial special issue on "Laser Doppler vibrometry"

    Science.gov (United States)

    Vanlanduit, Steve; Dirckx, Joris

    2017-12-01

    The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).

  1. MDCT urography: retrospective determination of optimal delay time after intravenous contrast administration

    International Nuclear Information System (INIS)

    Meindl, Thomas; Coppenrath, Eva; Kahlil, Rami; Reiser, Maximilian F.; Mueller-Lisse, U.G.; Mueller-Lisse, Ulrike L.

    2006-01-01

    The optimal delay time after intravenous (i.v.) administration of contrast medium (CM) for opacifcation of the upper urinary tract (UUT) for multidetector computed tomography urography (MDCTU) was investigated. UUT opacification was retrospectively evaluated in 36 four-row MDCTU examinations. Single- (n=10) or dual-phase (n=26) MDCTU was performed with at least 5-min delay after i.v. CM. UUT was divided into four sections: intrarenal collecting system (IRCS), proximal, middle and distal ureter. Two independent readers rated UUT opacification: 1, none; 2, partial; 3, complete. Numbers and percentages of scores, and the 5%, 25%, 50%, 75% and 95% percentiles of delay time were calculated for each UUT section. After removing diseased segments, 344 segments were analysed. IRCS, proximal and middle ureter were completely opacified in 94% (81/86), 93% (80/86) and 77% (66/86) of cases, respectively. Median delay time was 15 min for complete opacification. The distal ureter was completely opacified in 37% (32/86) of cases and not opacified in 26% (22/86). Median delay time for complete opacification was 11 min with 25% and 75% percentiles of 10 and 16 min, respectively. At MDCTU, opacification of the IRCS, proximal and middle ureter was hardly sensitive to delay time. Delay times between 10 and 16 min were favourable in the distal ureter. (orig.)

  2. Glare Spot Phase Doppler Anemometry

    OpenAIRE

    Hespel, Camille; Ren, Kuan Fang; Gréhan, Gérard; Onofri, Fabrice

    2006-01-01

    International audience; The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index is also necessary since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemo...

  3. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  4. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  5. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  6. Trichinella britovi human infection in Spain : antibody response to surface, excretory/secretory and somatic antigens

    Directory of Open Access Journals (Sweden)

    Rodríguez-Osorio M.

    2003-06-01

    Full Text Available A third outbreak of Trichinella britovi with 140 people involved, occurred in Granada Spain (December 1998. The source of infection was sausage made from uninspected wild boar meat. Fifty-two patients agreed to participated in this study. An elevated eosinophil level (> 5 % was detected in 59.6 % of patients, and persisted in most of these cases for two months. A moderate IgG response was observed. At the onset of symptoms, Western blot (WB test detected more positive cases than Enzyme linked immunosorbent assay (ELISA and indirect immunofluorescence (IIF. Six months from infection, ELISA revealed fewer positive cases than the other two tests. It would appear that the response to somatic antigens starts earlier than those to cuticular and excretory/secretory (ES antigens and that the response to ES antigens is the first to decrease.

  7. Longitudinal study of aortic isthmus Doppler in appropriately grown and small-for-gestational-age fetuses with normal and abnormal umbilical artery Doppler.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-04-01

    To establish reference ranges using longitudinal data for aortic isthmus (AoI) Doppler indices in appropriate-for-gestational-age (AGA) fetuses and to document the longitudinal trends in a cohort of small-for-gestational-age (SGA) fetuses with normal umbilical artery Doppler and in fetuses with intrauterine growth restriction (IUGR) and abnormal umbilical artery Doppler.

  8. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  9. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  10. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  11. Low osmolar (non-ionic) contrast media versus high osmolar (ionic) contrast media in intravenous urography and enhanced computerized tomography: a cost-effectiveness analysis.

    Science.gov (United States)

    Wangsuphachart, S

    1991-12-01

    The cost-effectiveness of three alternative policies for the use of intravenous contrast media for urography and enhanced computerized tomography (CT) are analyzed. Alternative #1 is to use high osmolar contrast media (HOCM) in all patients, the historical policy. Alternative #2 is to replace it with low osmolar contrast media (LOCM) in all patients. Alternative #3 is to use LOCM only in the high risk patients. Data on the 6,242 patients who underwent intravenous urography and enhanced CT at the Department of Radiology, Chulalongkorn Hospital in 1989 were used. Both societal and hospital viewpoints were analyzed. The incremental cost-effectiveness (ICE) between #2 and #1 was 26,739 Baht (US$1,070) per healthy day saved (HDS), while the ICE between #3 and #1 was 12,057 Baht (US$482) per HDS. For fatal cases only, ICE between #2 and #1 was 35,111 Baht (US$1,404) per HDS, while the ICE between #3 and #1 was 18,266 Baht (US$731) per HDS. The incremental cost (IC) per patient was 2,341 Baht (US$94) and 681 Baht (US$27) respectively. For the hospital viewpoint the ICE between #2 and #1 was 13,744 (US$550) and between #3 and #1 was 6,127 Baht (US$245) per HDS. The IC per patient was 1,203 Baht (US$48) and 346 Baht (US$14), respectively. From the sensitivity analysis, #3 should be used if the LOCM price is reduced more than 75% (equal to 626 Baht or less) and more than 80% of the patients are able to pay for the contrast media.

  12. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  13. Analysis of Radar Doppler Signature from Human Data

    Directory of Open Access Journals (Sweden)

    M. ANDRIĆ

    2014-04-01

    Full Text Available This paper presents the results of time (autocorrelation and time-frequency (spectrogram analyses of radar signals returned from the moving human targets. When a radar signal falls on the human target which is moving toward or away from the radar, the signals reflected from different parts of his body produce a Doppler shift that is proportional to the velocity of those parts. Moving parts of the body causes the characteristic Doppler signature. The main contribution comes from the torso which causes the central Doppler frequency of target. The motion of arms and legs induces modulation on the returned radar signal and generates sidebands around the central Doppler frequency, referred to as micro-Doppler signatures. Through analyses on experimental data it was demonstrated that the human motion signature extraction is better using spectrogram. While the central Doppler frequency can be determined using the autocorrelation and the spectrogram, the extraction of the fundamental cadence frequency using the autocorrelation is unreliable when the target is in the clutter presence. It was shown that the fundamental cadence frequency increases with increasing dynamic movement of people and simultaneously the possibility of its extraction is proportional to the degree of synchronization movements of persons in the group.

  14. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  15. Sequential hepato-biliary scintigraphy of the patients with constitutional jaundices and ICG excretory defect disease with sup(99m)Tc-HIDA and sup(99m)Tc-PI

    International Nuclear Information System (INIS)

    Ueda, Hideo; Asahara, Akira; Hishinuma, Sanpei; Toogin, Masayuki; Takagi, Masao

    1979-01-01

    The hepato-biliary scintigraphy with sup(99m)Tc-HIDA and sup(99m)Tc-PI and the measurement of hepatic clearance have been studied on constitutional hyperbilirubinemia and ICG excretory defect disease. The results obtained are as follows: 1) In Dubin-Johnson's syndrome cases, the hepatic uptake of sup(99m)Tc-HIDA was faster, but the excretion was extremely slower than in normal cases. 2) Hepatic uptake and excretion of sup(99m)Tc-PI were both almost normal in Dubin-Johnson's syndrome. 3) In Rotor's disease, hepatic uptake of sup(99m)Tc-HIDA was very poor, showing almost no hepatic image. 4) In Gilbert's disease and ICG excretory defect disease, hepatic uptake and excretion of sup(99m)Tc-HIDA were both within normal limit. From these results it can be presumed that Dubin-Johnson's syndrome and Rotor's disease differ in morbid condition. Dubin-Johnson's syndrome, Rotor's disease and Gilbert's disease show the different patterns between hepatic uptake and excretion on sup(99m)Tc-HIDA hepatoscintigraphy and the patterns contribute to the differential diagnosis of constitutional jaundice. (author)

  16. Sub-Doppler laser cooling of potassium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Landini, M. [LENS and Dipartimento di Fisica e Astronomia, Universita di Firenze, I-50019 Sesto Fiorentino (Italy); INFN, Sezione di Firenze, I-50019 Sesto Fiorentino (Italy); Dipartimento di fisica, Universita di Trento, I-38123 Povo (Trento) (Italy); Roy, S.; Carcagni, L.; Trypogeorgos, D. [LENS and Dipartimento di Fisica e Astronomia, Universita di Firenze, I-50019 Sesto Fiorentino (Italy); Fattori, M.; Inguscio, M.; Modugno, G. [LENS and Dipartimento di Fisica e Astronomia, Universita di Firenze, I-50019 Sesto Fiorentino (Italy); INFN, Sezione di Firenze, I-50019 Sesto Fiorentino (Italy)

    2011-10-15

    We investigate the sub-Doppler laser cooling of bosonic potassium isotopes, whose small hyperfine splitting has so far prevented cooling below the Doppler temperature. We find instead that the combination of a dark optical molasses scheme that naturally arises in this kind of system and an adiabatic ramping of the laser parameters allows us to reach sub-Doppler temperatures for small laser detunings. We demonstrate temperatures as low as 25{+-}3 {mu}K and 47{+-}5 {mu}K in high-density samples of the two isotopes {sup 39}K and {sup 41}K, respectively. Our findings should find application to other atomic systems.

  17. Sub-Doppler laser cooling of potassium atoms

    International Nuclear Information System (INIS)

    Landini, M.; Roy, S.; Carcagni, L.; Trypogeorgos, D.; Fattori, M.; Inguscio, M.; Modugno, G.

    2011-01-01

    We investigate the sub-Doppler laser cooling of bosonic potassium isotopes, whose small hyperfine splitting has so far prevented cooling below the Doppler temperature. We find instead that the combination of a dark optical molasses scheme that naturally arises in this kind of system and an adiabatic ramping of the laser parameters allows us to reach sub-Doppler temperatures for small laser detunings. We demonstrate temperatures as low as 25±3 μK and 47±5 μK in high-density samples of the two isotopes 39 K and 41 K, respectively. Our findings should find application to other atomic systems.

  18. Methodology for obtaining wind gusts using Doppler lidar

    DEFF Research Database (Denmark)

    Suomi, Irene; Gryning, Sven-Erik; O'Connor, Ewan J.

    2017-01-01

    reduced the bias in the Doppler lidar gust factors from 0.07 to 0.03 and can be improved further to reduce the bias by using a realistic estimate of turbulence. Wind gust measurements are often prone to outliers in the time series, because they represent the maximum of a (moving-averaged) horizontal wind...... detection also outperformed the traditional Doppler lidar quality assurance method based on carrier-to-noise ratio, by removing additional unrealistic outliers present in the time series.......A new methodology is proposed for scaling Doppler lidar observations of wind gusts to make them comparable with those observed at a meteorological mast. Doppler lidars can then be used to measure wind gusts in regions and heights where traditional meteorological mast measurements are not available...

  19. Corruption of radio metric Doppler due to solar plasma dynamics: S/X dual-frequency Doppler calibration for these effects

    Science.gov (United States)

    Winn, F. B.; Reinbold, S. R.; Yip, K. W.; Koch, R. E.; Lubeley, A.

    1975-01-01

    Doppler data from Mariner 6, 7, 9, and 10 and Pioneer 10 and 11 were discussed and the rms noise level for various sun-earth-probe angles were shown. The noise levels of both S- and X-band Doppler data for sun-earth-probe angles smaller than 20 deg were observed to be orders of magnitude greater than nominal. Such solar plasma-related Doppler degradation reduced the Mariner 10-Mercury 11 encounter navigation accuracy by nearly a factor of 10. Furthermore, this degradation was shown to be indirectly related to plasma dynamics and not a direct measure of the dynamics.

  20. Clinical study of retrocaval ureter diagnosed by CT scan

    International Nuclear Information System (INIS)

    Kiriyama, Isao; Hata, Ryosuke; Amemiya, Hiroshi

    1987-01-01

    Although retrocaval ureter is relatively uncommon congenital anomaly, surgical intervention is often necessary to alleviate the clinical signs and symptoms of the patients. Vena cavography has been indispensable imaging modality for the definitive diagnosis of this anomaly. Recently, however, CT scan in addition to excretory urography (IVP) and retrograde pyelography(RP) has been utilized in many reported cases in the diagnosis of retrocaval ureter. We have experienced 3 cases of retrocaval ureter consecutively. In this paper we report these 3 cases of retrocaval ureter, in which CT scan enabled us to confirm the definitive diagnosis. We also report another case of pelviureteric stenosis that was taken for retrocaval ureter by CT scan. Causes of the misdiagnosis is discussed. In conclusion CT scan is useful diagnostic modality in the diagnosis of retrocaval ureter and this lesser invasive technique might lessen the need for vena cavography. (author)

  1. Extracorporeal shock wave lithotripsy: Involvement and impact on radiology at a kidney stone center

    International Nuclear Information System (INIS)

    Cochran, S.T.; Barbaric, Z.L.; Mindell, H.; Chaussy, C.D.; Fuchs, G.J.

    1986-01-01

    Of 1,222 extracorporeal shock wave lithotripsy (ECSW) procedures performed on 925 patients (600 males, 325 females), 85% were unilateral and 35% were bilateral treatments. Treated were 446 calyceal, 345 pelvic, 172 uretral, and 108 staghorn calculi. The impact of this new technology to the radiology department was studied. An average of 6.3 KUB studies and 1.2 renal US studies were performed per treatment session. Six percent of patients required post-ESWL excretory urography of CT; 10% required percutaneous nephrostomy. Patients with treated staghorn calculi required the most radiologic procedures (34% performed for partial staghorn calculi, 56% for complete staghorn calculi). By comparison, 3%, 8%, and 11% of radiologic procedures were performed for calyceal, pelvic, and ureteral stones, respectively. The impact of ESWL on the radiology department can be substantial. When staghorn calculi are treated by ESWL, a radiologist skilled in interventional techniques is essential

  2. The urinary tract

    International Nuclear Information System (INIS)

    Thornbury, J.R.; Weiss, S.L.

    1987-01-01

    Introduction of new methods and enhancement of traditional radiologic methods have greatly influenced the use of imaging to diagnose and treat patients who have urinary tract disease. In the past, plain films of the abdomen and excretory urography were the starting point in the diagnostic imaging process. Today, either computed tomography (CT) or ultrasonography may be requested initially. Choosing the appropriate method has become more complex because of the variety that confronts the physician. If physicians think critically about the selection of patients before requesting an imaging examination, they can improve their use of such examinations. First, the physician must hypothesize a differential diagnosis. Particularly important is the action of linking the use of the diagnostic test to the choice of treatment. The following paragraphs present the most frequently used (or most useful) examinations for the specific diagnostic problem situations that are discussed subsequently

  3. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  4. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The EDOP provides vertically profiled reflectivity and Doppler velocity at aircraft nadir along the flight track. The ER-2 Doppler radar (EDOP) is an X-band (9.6...

  5. Gold nanorods as a contrast agent for Doppler optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Bo Wang

    Full Text Available To investigate gold nanorods (GNRs as a contrast agent to enhance Doppler optical coherence tomography (OCT imaging of the intrascleral aqueous humor outflow.A serial dilution of GNRs was scanned with a spectral-domain OCT device (Bioptigen, Durham, NC to visualize Doppler signal. Doppler measurements using GNRs were validated using a controlled flow system. To demonstrate an application of GNR enhanced Doppler, porcine eyes were perfused at constant pressure with mock aqueous alone or 1.0×10(12 GNR/mL mixed with mock aqueous. Twelve Doppler and volumetric SD-OCT scans were obtained from the limbus in a radial fashion incremented by 30°, forming a circular scan pattern. Volumetric flow was computed by integrating flow inside non-connected vessels throughout all 12 scans around the limbus.At the GNR concentration of 0.7×10(12 GNRs/mL, Doppler signal was present through the entire depth of the testing tube without substantial attenuation. A well-defined laminar flow profile was observed for Doppler images of GNRs flowing through the glass capillary tube. The Doppler OCT measured flow profile was not statistically different from the expected flow profile based upon an autoregressive moving average model, with an error of -0.025 to 0.037 mm/s (p = 0.6435. Cross-sectional slices demonstrated the ability to view anterior chamber outflow ex-vivo using GNR-enhanced Doppler OCT. Doppler volumetric flow measurements were comparable to flow recorded by the perfusion system.GNRs created a measureable Doppler signal within otherwise silent flow fields in OCT Doppler scans. Practical application of this technique was confirmed in a constant pressure ex-vivo aqueous humor outflow model in porcine eyes.

  6. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  7. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  8. Influence of drugs with antioxidant properties on the state of the sperm antioxidant system in men with excretory-toxic forms of infertility

    Directory of Open Access Journals (Sweden)

    O.K. Onufrovych

    2013-10-01

    Full Text Available Since the development of many disorders of the reproductive function in men involves processes of free radical oxidation, the purpose of this study was to form an evaluation of the pro- and antioxidant status of sperm and to restore its biological usefulness in men with excretory-toxic forms of infertility by using drugs with antioxidant properties. It is shown that excretory-toxic forms of infertility in men are mostly caused by such infectious agents as Chlamydia (22%, Chlamydia + Ureaplasma (16%, Chlamydia + Trichomonas (13%, Ureaplasma (10%. This reduces the total number of sperm in the ejaculate by 2.7 times, and motility by 1.8 times. The number of abnormal forms increases by 1.75 times. With the development of chronic inflammation of the male sex organs sperm lipid peroxidation increases by 1.3 times while the activity of glutathione peroxidase decreases (by 2.3 times and that of glutathione reductase (by 1.7 times. We observed a close correlation between the low biological quality of sperm (low concentration, low number and motility of sperm in the ejaculate with activation of lipid peroxidation and inhibition of activity of the glutathione antioxidant system. In the case of superoxide dismutase, the negative impact of reactive oxygen species on this enzyme was not observed. A course of drugs with antioxidant properties – vitamin E, vitamin C and zinc sulfate leads to improvement in the indicators on the spermagram (mostly sperm mobility and morphology, to reduction of the number of peroxide compounds and activation of the glutathione antioxidant system. In this case, the activity of glutathione peroxidase is increased by 1.5 times and the activity of glutathione reductase by 1.3 times. The activity of superoxide dismutase at the same time approaches the norm for zoospermia. The data obtained show that one of the pathogenic factors of the chronic inflammation of male sex organs, considered as a main developmental reason for infertility

  9. Integrated imaging (ultrasound, computed tomography, intravenous urography) in diagnosing renal tumors and tumor-like formations

    International Nuclear Information System (INIS)

    Drudi, F.M.; Capanna, G.; Poggi, R.; Occhiato, R.; Iannicelli, E.; Nardo, R.; di Passariello, R.

    1994-01-01

    This is an assessment of semiologic imaging criteria based on computerised tomography, ultrasound diagnosis and intravenous urography in renal tumors. The purpose is to obtain differential diagnostic data capable to modify the treatment approach. Over the last three years, a total of 570 cases of kidney tumors are observed. In 490 of them (86%) the imaging patterns obtained by either of the three techniques leads to correct diagnosis. In 62 of the remaining 80 patients, the integration of two techniques allows to unveil the neoplastic nature of the disease (27 cases), or the presence of a benign process (35 cases). In 15 of the remaining 18 cases only integration of the three techniques results in diagnosing renal tumors or tumor-like conditions (3 adeno-carcinomas, 5 abscesses, 3 cases of tuberculosis, 2 - pyeloxanthogranulomatosis, 2 dysmorphisms). In the last three cases definite diagnosis is made on the basis of needle biopsy. The radiological diagnosis is confirmed intraoperatively or during clinical follow-up study. The obtained data underscore the clinical relevance of imaging integration in evaluating renal lesions. This is particularly valid whenever the clinical data are nonspecific or misleading. 15 refs., 3 figs., 5 tabs. (orig.)

  10. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  11. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    Science.gov (United States)

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  12. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  13. MR urography versus retrograde pyelography/ureteroscopy for the exclusion of upper urinary tract malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.S., E-mail: kslee@bidmc.harvard.ed [Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Zeikus, E. [Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States); DeWolf, W.C. [Department of Surgery, Division of Urology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Rofsky, N.M.; Pedrosa, I. [Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States)

    2010-03-15

    Aim: To evaluate the diagnostic performance of magnetic resonance urography (MRU) versus retrograde pyelography and/or ureteroscopy (RPU) in the detection of upper urinary tract neoplasms. Materials and methods: This retrospective study included 35 patients with suspected upper urinary tract malignancy who underwent MRU and RPU within 6-months in our institution during the study period (February 2002 to January 2007). MRU and RPU reports were reviewed and results recorded. For each patient, the urinary tract was sub-divided into four regions for analysis: left kidney/renal pelvis, left ureter, right kidney/renal pelvis, and right ureter. MRU and RPU results for each patient were compared to a reference standard and the diagnostic performance of both techniques was compared. Results: A total of 113 regions were analysed on MRU and 90 regions on RPU. Nineteen neoplasms were identified. Sensitivity, specificity, positive predictive value, and negative predictive value for the detection of urinary tract neoplasms were 63, 91, 60, and 92% for MRU, respectively, and 53, 97, 83, and 88% for RPU, respectively. These differences were not statistically significant (p > 0.05). Conclusion: The high negative predictive value of MRU in the present series supports its use as a non-invasive screening examination for excluding the presence of upper urinary tract malignancy.

  14. The diagnostic value of magnetic resonance urography using a balanced turbo field echo sequence

    Energy Technology Data Exchange (ETDEWEB)

    Cifci, Egemen; Coban, Goekcen [Baskent University Faculty of Medicine, Department of Radiology, Konya (Turkey); Cicek, Tufan; Goenuelalan, Umut [Baskent University Faculty of Medicine, Department of Urology, Konya (Turkey)

    2016-12-15

    The aim of the study was to compare the inter-observer variability and the accuracy of magnetic resonance urography (MRU) using a thin sectional balanced-turbo field echo (B-TFE) sequence for detecting ureteral calculi and to determine the effect of additional factors (size, density and location of the calculus) on the sensitivity and specificity of the MRU. MRU and CT images were evaluated independently by two radiologists according to presence, density and localization of calculi. The degrees of inter-rater agreement for categorical items were evaluated by the Kappa coefficient. According to the 1st and 2nd observers, the sensitivity of MRU was 65.9 %, 71.8 % and the specificity of MRU was 95.9 %, 100 %, respectively. Inter-observer agreement was 84.6 % for stone detection. The larger size had a better effect on detectability (p < 0.05). Also, the higher density had a better impact on detectability (p < 0.05). Our study has shown that B-TFE MRU was useful to detect ureteral calculi. However, B-TFE MRU has low sensitivity and high specificity in comparison with CT images. MRU is a reasonable alternative imaging technique for follow-up periods of selective groups like patients with large urinary stones, children or pregnant patients when ionizing radiation is undesirable. (orig.)

  15. Temporal Doppler Effect and Future Orientation: Adaptive Function and Moderating Conditions.

    Science.gov (United States)

    Gan, Yiqun; Miao, Miao; Zheng, Lei; Liu, Haihua

    2017-06-01

    The objectives of this study were to examine whether the temporal Doppler effect exists in different time intervals and whether certain individual and environmental factors act as moderators of the effect. Using hierarchical linear modeling, we examined the existence of the temporal Doppler effect and the moderating effect of future orientation among 139 university students (Study 1), and then the moderating conditions of the temporal Doppler effect using two independent samples of 143 and 147 university students (Studies 2 and 3). Results indicated that the temporal Doppler effect existed in all of our studies, and that future orientation moderated the temporal Doppler effect. Further, time interval perception mediated the relationship between future orientation and the motivation to cope at long time intervals. Finally, positive affect was found to enhance the temporal Doppler effect, whereas control deprivation did not influence the effect. The temporal Doppler effect is moderated by the personality trait of future orientation and by the situational variable of experimentally manipulated positive affect. We have identified personality and environmental processes that could enhance the temporal Doppler effect, which could be valuable in cases where attention to a future task is necessary. © 2016 Wiley Periodicals, Inc.

  16. Filarial excretory-secretory products induce human monocytes to produce lymphangiogenic mediators.

    Directory of Open Access Journals (Sweden)

    Tiffany Weinkopff

    2014-07-01

    Full Text Available The nematodes Wuchereria bancrofti and Brugia spp. infect over 120 million people worldwide, causing lymphedema, elephantiasis and hydrocele, collectively known as lymphatic filariasis. Most infected individuals appear to be asymptomatic, but many exhibit sub-clinical manifestations including the lymphangiectasia that likely contributes to the development of lymphedema and elephantiasis. As adult worm excretory-secretory products (ES do not directly activate lymphatic endothelial cells (LEC, we investigated the role of monocyte/macrophage-derived soluble factors in the development of filarial lymphatic pathology. We analyzed the production of IL-8, IL-6 and VEGF-A by peripheral blood mononuclear cells (PBMC from naïve donors following stimulation with filarial ES products. ES-stimulated PBMCs produced significantly more IL-8, IL-6 and VEGF-A compared to cells cultured in medium alone; CD14(+ monocytes appear to be the primary producers of IL-8 and VEGF-A, but not IL-6. Furthermore, IL-8, IL-6 and VEGF-A induced in vitro tubule formation in LEC Matrigel cultures. Matrigel plugs supplemented with IL-8, IL-6, VEGF-A, or with supernatants from ES-stimulated PBMCs and implanted in vivo stimulated lymphangiogenesis. Collectively, these data support the hypothesis that monocytes/macrophages exposed to filarial ES products may modulate lymphatic function through the secretion of soluble factors that stimulate the vessel growth associated with the pathogenesis of filarial disease.

  17. Calculation of the Doppler broadening function using Fourier analysis

    International Nuclear Information System (INIS)

    Goncalves, Alessandro da Cruz

    2010-01-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function ψ(x,ζ) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for ψ(x,ζ), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  18. Interest of 99mTc-DMSA in the exploration of non-functional kidneys in the intravenous urography; report of 20 cases

    International Nuclear Information System (INIS)

    Ghfir, I.; Ouboukdir, R.; Ben Rais, N.

    2008-01-01

    Introduction The renal scintigraphy using 99m Tc-DMSA constitutes a non-invasive and functional method that is of appreciable interest in the qualitative study of renal parenchyma and the evaluation of the separate renal function. Material and methods We report, through this work, the observation of 20 patients presenting a unilateral renal muteness to the intravenous urography (I.V.U.). A 99m Tc-DMSA scintigraphy was carried out among all our patients by means of a gamma-camera with large field equipped with a parallel collimator of weak energy and high-resolution. The evaluation of images obtained consisted of a qualitative study of parenchyma as well as an estimate of the functional value separated from the two kidneys obtained by the calculation of geometric mean. Results On the 20 studied cases, the sex-ratio was equal to 1.16; the average age was 29.72 years with extremes spanning from 18 months to 70 years. The renal muteness reported on intravenous urography was due among 12 patients (60% of cases) to a lithiasis origin, in six patients (30% of cases), to an ureteral-pelvic junction, in one patient (5% of cases), to a chronic pyelonephritis and in another patient (5% of cases) to a mega urethra. The separated renal function of the non functional kidneys to the I.V.U., obtained from the renal 99m Tc-DMSA scintigraphy varied from 11% to 31% with an average of 20.6%. Discussion Through our series, 99m Tc-DMSA scintigraphy allowed to alleviate the limits of I.V.U. in the evaluation of the precise functional value of pathologic kidneys. Indeed, in the 20 studied cases where the I.V.U. had reported a renal muteness, the 99m Tc-DMSA scintigraphy allowed a better appreciation of the renal function which varied from 11% to 31% thus calling into question the accuracy of I.V.U. in the exploration of renal function at an advanced stage of uropathy. (N.C.)

  19. New clutter-rejection algorithm for Doppler ultrasound

    Science.gov (United States)

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2002-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): a time-varying low frequency component (type 1), covering systole and early diastole, and short transient clutter signals (type 2), distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted until the signal-to-clutter (S/C) ratio reached a maximum. For the type 1 clutter signal, the improvement in the S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient type 2 clutter signal, exactly 10 atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  20. Inline Ultrasonic Rheometry by Pulsed Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  1. Molecules cooled below the Doppler limit

    Science.gov (United States)

    Truppe, S.; Williams, H. J.; Hambach, M.; Caldwell, L.; Fitch, N. J.; Hinds, E. A.; Sauer, B. E.; Tarbutt, M. R.

    2017-12-01

    Magneto-optical trapping and sub-Doppler cooling have been essential to most experiments with quantum degenerate gases, optical lattices, atomic fountains and many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A magneto-optical trap (MOT) has been demonstrated for a single molecular species, SrF, but the sub-Doppler temperatures required for many applications have not yet been reached. Here we demonstrate a MOT of a second species, CaF, and we show how to cool these molecules to 50 μK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study collisions and chemistry between atoms and molecules at ultracold temperatures.

  2. Comparison of excretory-secretory antigen and positive faecal supernatant antigen in the detection of Echinococcus granulosus infection in dogs by CIEP

    Directory of Open Access Journals (Sweden)

    P. R. Prathiush

    Full Text Available Coproantigen detection of Echinococcosis in dogs by counter immunoelectrophoresis was standardized. Adult Echinococcus granulosus worms were obtained from intestine of a necropsied positive dog. Excretory-secretory antigen was prepared by culturing adult worms in Medium 199 (pH 7.4. Faeces of positive dog were collected and fecal supernatant was prepared and used for coproantigen detection. CIEP was carried out using tris-borate buffer (pH 8.0 at a constant current of 8mA/slide for 60 minutes. CIEP detected infection with both the antigens. [Vet World 2009; 2(11.000: 421-422

  3. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  4. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  5. Contrast-enhanced power Doppler US in the characterization of renal masses; Power Doppler con mezzo di contrasto nella caratterizzazione delle masse renali

    Energy Technology Data Exchange (ETDEWEB)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E. [Messina Univ., Messina (Italy). Ist. di Scienze Radiologiche

    2000-09-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts. [Italian] Scopo di questo articolo e' quello di riportare i risultati di uno studio prospettico finalizzato ad individuare le potenzialita' del power Doppler con mdc ecografico nella caratterizzazione delle lesioni espansive del rene. Dal 1997 al 30 ottobre 1999 sono state studiate 59 lesioni renali (28 maligne, 31 benigne) in 48 pazienti (eta' media 55 anni, intervallo 10

  6. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  7. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  8. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  9. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking

    Directory of Open Access Journals (Sweden)

    Armstrong J. W.

    2006-01-01

    Full Text Available This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (~millihertz gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity $2 Delta v/c = Delta u/ u_0$, where $Delta u$ is the Doppler shift and $ u_0$ is the radio link carrier frequency. A gravitational wave having strain amplitude $h$ incident on the earth-spacecraft system causes perturbations of order $h$ in the time series of $Delta u/ u_0$. Unlike other detectors, the ~1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series, some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  10. Laser Doppler measurements in two-phase flows

    International Nuclear Information System (INIS)

    Durst, F.; Zare, M.

    1976-01-01

    Basic theory for laser-Doppler velocity measurements of large reflecting or refracting surfaces is provided. It is shown that the Doppler-signals contain information of the velocity and size of the large bodies, and relationships for transforming velocity and radius of curvature of moving spheres are presented. Preliminary experiments verified the analytical findings and demonstrated the applicability of the method to some two-phase flows

  11. Transversal Doppler-Fizeau effect

    International Nuclear Information System (INIS)

    Subacius, E.

    1981-01-01

    The relativistic calculation of the Doppler-Fizeau effect foresees a second grade redshift due to the proper time dilation of a moving object. The relevance of this relativistic effect on astrophysical observation is discussed, herein. (Auhor) [pt

  12. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  13. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    The authors searched all ... quasar, where the contribution of the Doppler motion is relatively small. ..... might contribute to the Doppler redshift distribution. 5. ... out accounting for the contamination of intervening absorption systems, which can.

  14. Settings and artefacts relevant for Doppler ultrasound in large vessel vasculitis

    DEFF Research Database (Denmark)

    Terslev, L; Diamantopoulos, A P; Døhn, U Møller

    2017-01-01

    Ultrasound is used increasingly for diagnosing large vessel vasculitis (LVV). The application of Doppler in LVV is very different from in arthritic conditions. This paper aims to explain the most important Doppler parameters, including spectral Doppler, and how the settings differ from those used...

  15. [Diagnostic value of power Doppler ultrasonography for Sirenomelia Seguence in prenatal].

    Science.gov (United States)

    Yan, Xia-yu; Yang, Tai-zhu; Luo, Hong; Tian, Yu; Yang, Fan

    2011-11-01

    To study and discuss the diagnostic value and ultrasonographic characteristics of power doppler ultrasound in the prenatal diagnosis of Sirenomelia Seguence. The abdominal aorta in two fetuses with sirenomelia seguence fetuses and in ten with nomal was reviewed and compared with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound in prenatal. The abdominal aorta were showed to divid into renal arteries in the kidney level while two common iliac arteries in the pelvis in nomal fetuses with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound; compared with the nomal, the abdominal aorta and whose branches in sirenomelia seguence were demonstrated as follows: 1) a large and deformed vascular coming from the high abdominal aorta, which was found to act as a umbilical artery by careful examination; 2) no bifurcation of renal arteries identified; 3) no bifurcation of two common iliac arteries identified; 4) the abdominal aorta changing into a narrow vascular after one deformed vascular separating from. Sirenomelia seguence fetuses has a characteristic change in two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound, which is helpful to improve the prenatal diagnosis of sirenomelia seguence.

  16. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    International Nuclear Information System (INIS)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon

    2002-01-01

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  17. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  18. Pediatric hypertension: An approach to imaging

    International Nuclear Information System (INIS)

    Diament, M.J.; Stanley, P.; Gilsanz, V.; Boechat, M.I.; Kangarloo, H.; Lieberman, E.R.

    1986-01-01

    Since 1981, we have made diagnoses of secondary hypertension using state of art imaging equipment in 18 pediatric patients. The most valuable tests were ultrasound identifying renal parenchymal disease, computed body tomography for adrenal tumors and intra-arterial renal angiography for renovascular disorders. Based on our experience, we have formulated an algorithm for the evaluation of the hypertensive pediatric patient. The initial step is careful clinical and laboratory screening to identify those patients that are likely to have essential hypertension and who should not undergo imaging tests. In the cases where there is a possible secondary etiology, renal ultrasound is usually performed first to identify parenchymal disease. If catecholamines are elevated, then abdominal computed tomography is the initial test. If no etiology is identified from these noninvasive studies, then direct intraarterial renal angiography is performed. The authors do not feel that excretory urography, radionuclide renography, intravenous digital subtraction angiography or selective renal vein sampling for renin are useful or practical screening tests for renovascular hypertension. (orig.)

  19. Pediatric hypertension: An approach to imaging

    Energy Technology Data Exchange (ETDEWEB)

    Diament, M J; Stanley, P; Gilsanz, V; Boechat, M I; Kangarloo, H; Lieberman, E R

    1986-09-01

    Since 1981, we have made diagnoses of secondary hypertension using state of art imaging equipment in 18 pediatric patients. The most valuable tests were ultrasound identifying renal parenchymal disease, computed body tomography for adrenal tumors and intra-arterial renal angiography for renovascular disorders. Based on our experience, we have formulated an algorithm for the evaluation of the hypertensive pediatric patient. The initial step is careful clinical and laboratory screening to identify those patients that are likely to have essential hypertension and who should not undergo imaging tests. In the cases where there is a possible secondary etiology, renal ultrasound is usually performed first to identify parenchymal disease. If catecholamines are elevated, then abdominal computed tomography is the initial test. If no etiology is identified from these noninvasive studies, then direct intraarterial renal angiography is performed. The authors do not feel that excretory urography, radionuclide renography, intravenous digital subtraction angiography or selective renal vein sampling for renin are useful or practical screening tests for renovascular hypertension.

  20. Teardrop bladder: additional considerations

    International Nuclear Information System (INIS)

    Wechsler, R.J.; Brennan, R.E.

    1982-01-01

    Nine cases of teardrop bladder (TDB) seen at excretory urography are presented. In some of these patients, the iliopsoas muscles were at the upper limit of normal in size, and additional evaluation of the perivesical structures with computed tomography (CT) was necessary. CT demonstrated only hypertrophied muscles with or without perivesical fat. The psoas muscles and pelvic width were measured in 8 patients and compared with the measurements of a control group of males without TDB. Patients with TDB had large iliopsoas muscles and narrow pelves compared with the control group. The psoas muscle width/pelvic width ratio was significantly greater (p < 0.0005) in patients with TDB than in the control group, with values of 1.04 + 0.05 and 0.82 + 0.09, respectively. It is concluded that TDB is not an uncommon normal variant in black males. Both iliopsoas muscle hypertrophy and a narrow pelvis are factors that predispose a patient to TDB

  1. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  2. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    International Nuclear Information System (INIS)

    Showman, Adam P.; Lewis, Nikole K.; Fortney, Jonathan J.; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation—and Doppler signature—of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the ∼2 km s –1 blueshift inferred on HD 209458b may require drag time constants as short as 10 4 -10 6 s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  3. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  4. Doppler-musical instrument

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.J. [National Research Institute for Metals, Tsukuba, Ibaraki (Japan); Watanabe, N. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Shibata, K. [Institute for Materials Research, Tohoku Univ., Sendai, Miyagi (Japan)

    2001-03-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 {mu}eV, even when the ultra-high energy resolution of {delta}E{approx}0.03 {mu}eV is attained. (author)

  5. Trans-skull ultrasonic Doppler system aided by fuzzy logic

    Science.gov (United States)

    Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto

    2012-06-01

    This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.

  6. Spectroscopic Doppler analysis for visible-light optical coherence tomography

    Science.gov (United States)

    Shu, Xiao; Liu, Wenzhong; Duan, Lian; Zhang, Hao F.

    2017-12-01

    Retinal oxygen metabolic rate can be effectively measured by visible-light optical coherence tomography (vis-OCT), which simultaneously quantifies oxygen saturation and blood flow rate in retinal vessels through spectroscopic analysis and Doppler measurement, respectively. Doppler OCT relates phase variation between sequential A-lines to the axial flow velocity of the scattering medium. The detectable phase shift is between -π and π due to its periodicity, which limits the maximum measurable unambiguous velocity without phase unwrapping. Using shorter wavelengths, vis-OCT is more vulnerable to phase ambiguity since flow induced phase variation is linearly related to the center wavenumber of the probing light. We eliminated the need for phase unwrapping using spectroscopic Doppler analysis. We split the whole vis-OCT spectrum into a series of narrow subbands and reconstructed vis-OCT images to extract corresponding Doppler phase shifts in all the subbands. Then, we quantified flow velocity by analyzing subband-dependent phase shift using linear regression. In the phantom experiment, we showed that spectroscopic Doppler analysis extended the measurable absolute phase shift range without conducting phase unwrapping. We also tested this method to quantify retinal blood flow in rodents in vivo.

  7. A study of doppler waveform using pulsatile flow model

    International Nuclear Information System (INIS)

    Chung, Hye Won; Chung, Myung Jin; Park, Jae Hyung; Chung, Jin Wook; Lee, Dong Hyuk; Min, Byoung Goo

    1997-01-01

    Through the construction of a pulsatile flow model using an artificial heart pump and stenosis to demonstrate triphasic Doppler waveform, which simulates in vivo conditions, and to evaluate the relationship between Doppler waveform and vascular compliance. The flow model was constructed using a flowmeter, rubber tube, glass tube with stenosis, and artificial heart pump. Doppler study was carried out at the prestenotic, poststenotic, and distal segments;compliance was changed by changing the length of the rubber tube. With increasing proximal compliance, Doppler waveforms show decreasing peak velocity of the first phase and slightly delayed acceleration time, but the waveform itself did not change significantly. Distal compliance influenced the second phase, and was important for the formation of pulsus tardus and parvus, which without poststenotic vascular compliance, did not develop. The peak velocity of the first phase was inversely proportional to proximal compliance, and those of the second and third phases were directly proportional to distal compliance. After constructing this pulsatile flow model, we were able to explain the relationship between vascular compliance and Doppler waveform, and also better understand the formation of pulsus tardus and parvus

  8. Response of a Doppler canceling system to plane gravitational waves

    International Nuclear Information System (INIS)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-canceled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences

  9. Micro-Doppler Ambiguity Resolution Based on Short-Time Compressed Sensing

    Directory of Open Access Journals (Sweden)

    Jing-bo Zhuang

    2015-01-01

    Full Text Available When using a long range radar (LRR to track a target with micromotion, the micro-Doppler embodied in the radar echoes may suffer from ambiguity problem. In this paper, we propose a novel method based on compressed sensing (CS to solve micro-Doppler ambiguity. According to the RIP requirement, a sparse probing pulse train with its transmitting time random is designed. After matched filtering, the slow-time echo signals of the micromotion target can be viewed as randomly sparse sampling of Doppler spectrum. Select several successive pulses to form a short-time window and the CS sensing matrix can be built according to the time stamps of these pulses. Then performing Orthogonal Matching Pursuit (OMP, the unambiguous micro-Doppler spectrum can be obtained. The proposed algorithm is verified using the echo signals generated according to the theoretical model and the signals with micro-Doppler signature produced using the commercial electromagnetic simulation software FEKO.

  10. Korea-China Joint R and D on Doppler Lidar Technology

    International Nuclear Information System (INIS)

    Cha, Hyung Ki; Kim, D. H.; Kwon, S. O.; Yang, K. H.; Song, I. K.

    2009-03-01

    Doppler lidar technology is to monitor atmospheric wind velocity by measuring the light scattering signals between a laser and aerosol particles or molecules existing in the atmosphere. When the particles (or molecules) in the atmosphere are moving by wind force, the frequency of backscattering light is shifted by doppler effect, so that the wind velocity profile can be obtained by measurement of the shifted frequencies. When the laser radiation is scanned in four different direction, three dimensional wind profiles are obtained. The Anhui Institute of Optics and Fine Mechanics under the China Academy of Sciences has developed and operated the doppler lidar system for long time. In this project we want to developed a new technologies adopted to the chinese doppler system and to test the updated In the process of collaboration between China and Korea research teams, we want to learn the state-of-art technology involved in the doppler lidar system

  11. A prospective survey of delayed adverse reactions to iohexol in urography and computed tomography

    International Nuclear Information System (INIS)

    Munechika, Hirotsugu; Hiramatsu, Yoshihiro; Kudo, Sho; Sugimura, Kazuro; Hamada, Chikuma; Yamaguchi, Koichi; Katayama, Hitoshi

    2003-01-01

    We investigated 7505 inpatients who underwent intravenous urography or contrast-enhanced computed tomography to assess risk factors for delayed adverse drug reactions to iohexol, a non-ionic iodinated contrast medium. Focusing on delayed adverse reactions, all adverse events were prospectively investigated for 7 days after injection of iohexol. To explore the relevant risk factors, the relationship between occurrence of adverse reactions to iohexol and 17 different variables was evaluated by logistic regression analysis. To assess the influence of seasonal factors, adverse reactions were separately evaluated during two periods: February to April (the pollinosis period in Japan) and July to September (the non-pollinosis period). The prevalence of delayed adverse events and delayed adverse reactions was 3.5 and 2.8%, respectively, whereas the prevalence of adverse events and adverse reactions was 5.7 and 5.0%, respectively. Multivariate analysis showed that six parameters had a significant influence on delayed adverse reactions to iohexol, including (a) a history of allergy, (b) season, (c) radiographic procedure, (d) age, (e) concomitant surgery or other invasive procedures, and (f) concomitant medication. The prevalence of delayed reactions was lower than in previous large-scale studies. Significant risk factors included a history of allergy and performance of radiography during the pollinosis period, suggesting that allergy was involved in delayed adverse reactions. The type of radiographic procedure also had an influence. (orig.)

  12. The effectiveness of Doppler controlled hemorrhoidal artery ligation ...

    African Journals Online (AJOL)

    In this work, we discuss the preliminary results of the effectiveness of the hemorrhoidal artery ligation under control Doppler as a new technique for the treatment of hemorrhoids. We report the results of patients with hemorrhoids we have followed over a period of one year who were treated with HAL Doppler. The intra-and ...

  13. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  14. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  15. Lorentz invariance and the rotor Doppler shift experiments

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1984-01-01

    It is shown that 'Rotor Doppler shift Experiments' provide a way to distinguish Einstein's Special Relativity (SR) from Lorentz's Aether Theory (LAT). Misconceptions in previous papers involving the Doppler shift experiments are examined. The theoretical and experimental data available on rotor Doppler shift experiments are analysed. Two models of SR violating theories are used to predict the output of a recently proposed experiment by Torr and Kolen. The first one corresponds to (strict) LAT and the other to an extended form of LAT Contrary to the first, the second theory leads to results in agreement with the preliminary experimental data of Torr et al indicating a breakdown both of SR and strict LAT. (Author) [pt

  16. Lorentz invariance and the rotor Doppler shift experiments

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1984-01-01

    It is shown that 'Rotor Doppler shift Experiments' provide a way to distinguish Einstein's Special Relativity (SR) from Lorentz's Aether Theory (LAT). Misconceptions in previous papers involving the Doppler shift experiments are examined. The theoretical and experimental data available on rotor Doppler shift experiments are analysed. Two models of SR violating theories are used to predict the output of a recently proposed experiment by Torr and Kolen. The first one corresponds to (strict) LAT and the other to an extended form of LAT. Contrary to the first, the second theory leads to results in agreement with the preliminary experimental data of Torr et al indicating a breakdown both of SR and strict LAT. (Author) [pt

  17. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  18. Análisis de perforantes de la epigástrica inferior profunda con Angio TC 3D, Eco Doppler color y Doppler simple de ultrasonidos en colgajo DIEP: resultados preliminares Analysis of deep inferior epigastric perforating vessels with 3D CT angiography, color Doppler ultrasonography and Doppler in diep flaps: preliminary results

    Directory of Open Access Journals (Sweden)

    J. Castro García

    2008-09-01

    Full Text Available Nuestro objetivo es la validación de la Angio TC tridimensional como herramienta de planificación de los colgajos DIEP, comparándolo con el Doppler de ultrasonidos (US y eco Doppler color. Entre enero de 2006 y marzo de 2007 se realiza en 11 pacientes (13 DIEP un estudio comparativo prospectivo entre el Doppler de US, eco Doppler color y Angio TC con reconstrucción tridimensional, utilizando como dato de referencia los hallazgos intraoperatorios. En dicho proceso se localiza la mejor perforante que pueda servir como pedículo al colgajo DIEP en función de su localización, calibre, trayecto y relaciones anatómicas con respecto al músculo. La Angio TC con reconstrucción tridimensional, demuestra una especificidad del 100% (IC 95% 75.3-100 lo que le convierte en una prueba con un alto valor predictivo positivo y una excelente herramienta en la planificación de los colgajos de perforantes. El eco Doppler color determinó, que tan sólo en un 46,1% (IC 95% 19,2-74,9 de los pacientes, la perforante seleccionada por la prueba de forma preoperatoria, coincidía con la perforante elegida en quirófano. Con el Doppler de US, en un 30,8 % (IC 95% 9,1-61,4 de los colgajos estudiados, coincidía la mejor perforante escogida de forma preoperatoria, con los hallazgos obtenidos tras la disección del colgajo. En el presente estudio, la Angio TC tridimensional se ha mostrado como una técnica con una gran especificidad que proporciona valiosa información, sólo comparable con la disección anatómica y por delante de pruebas como el Doppler de ultrasonidos y el eco Doppler color.The aim of this report, is to validate the Angio-CT technique with three-dimentional reconstruction as a preoperative planning tool, after comparison with Doppler ultrasound and color- Duplex. Between january 2006 and march 2007, we studied 11 consecutive patients (13 DIEP in whom a prospective comparative followed up was performed comparing, the findings observed using

  19. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  20. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  1. Studies on the influence on the excretory kinetics of 125I-Adipiodon

    International Nuclear Information System (INIS)

    Koenig, H.

    1982-01-01

    The possibility of influencing distribution and elimination of 125 I-Adipiodon ( 125 I-iodipamide meglumine) by a preceding administration of Falignost (iomeglamic acid) as well as by dose-time variants of the mechanic intravenous application of contrast medium was tested in 55 anicteric and 2 icteric patients within clinically indicated cholegraphic examination with the aim of methodical optimization. For the detection of principal regularities comparative studies with 125 I-Adipiodon and Falignost in rats as well as examinations of protein binding of 125 I-Adipiodon in the plasm of rats and in the plasm and in mixed serum (application in vitro) of patients by gel filtration with Epidex B 2 coarse and batch operation on more than 1,200 samples were additionally carried out. For combined cholecystography with intravenous infusion of Adipiodon in immediate temporal connection with the administration of Falignost a reduced visibility of the biliary tract in the X-ray picture is not to be expected as the consequence of the mutual influence of the contrast media. For intact excretory function of liver and kidneys the combined cholecystography can be recommended. The effects of a dose increase, of protracted infusion of Adipiodon and of the intravenous administration of 0.01 g metroclopramide on the demonstration of the biliary tract in the intravenous cholegram are outlined. (author)

  2. Characterisation of proteolytic activity of excretory-secretory products from adult Strongylus vulgaris.

    Science.gov (United States)

    Caffrey, C R; Ryan, M F

    1994-04-01

    An excretory-secretory (ES) preparation derived from adult Strongylus vulgaris in vitro was assessed for proteolytic activity using azocasein and synthetic, fluorogenic, peptide substrates. Fractionation was by molecular sieve fast protein liquid chromatography (molecular sieve FPLC) and resolution by gelatin-substrate sodium dodecyl sulphate-polyacrylamide gel electrophoresis (gelatin-substrate SDS-PAGE). The cysteine proteinase activator, dithiothreitol (DTT), enhanced azocaseinolysis and hydrolysis of carbobenzoxy-phenylalanyl-arginine-7-amido-4-methylcoumarin (Z-Phe-Arg-NMec) by the ES preparation and was a requirement for the detection of carbobenzoxy-arginyl-arginine-7-amido-4-methylcoumarin (Z-Arg-Arg-NMec) hydrolysis. Assays of FPLC-eluted fractions, with DTT, detected a broad peak of azocaseinolytic activity (22-24 kDa) and two peaks (24 and 18 kDa) of hydrolysis using the synthetic substrates. Hydrolysis by these peaks of Z-Phe-Arg-NMec was 50-fold greater than that of Z-Arg-Arg-NMec suggesting that their specificities are more like papain or cathepsin L rather than cathepsin B. In gelatin-substrate SDS-PAGE, DTT was required to detect proteolysis by the ES preparation which was optimal at pH 6.0 and resolved into eight bands (87-29 kDa). Cysteine proteinase inhibitors were the most effective in all assays. Collectively, these data indicate that cysteine-class proteolytic activity predominates in the ES preparation of adult S. vulgaris.

  3. Doppler electron velocimetry : notes on creating a practical tool.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.; Milster, Tom (University of Arizona)

    2008-11-01

    The Doppler electron velocimeter (DEV) has been shown to be theoretically possible. This report attempts to answer the next logical question: Is it a practical instrument? The answer hinges upon whether enough electrons are available to create a time-varying Doppler current to be measured by a detector with enough sensitivity and bandwidth. The answer to both of these questions is a qualified yes. A target Doppler frequency of 1 MHz was set as a minimum rate of interest. At this target a theoretical beam current signal-to-noise ratio of 25-to-1 is shown for existing electron holography equipment. A detector is also demonstrated with a bandwidth of 1-MHz at a current of 10 pA. Additionally, a Linnik-type interferometer that would increase the available beam current is shown that would offer a more flexible arrangement for Doppler electron measurements over the traditional biprism.

  4. Micro-Doppler classification of riders and riderless horses

    Science.gov (United States)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  5. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  6. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  7. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    Science.gov (United States)

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  8. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... include signal analysis and display equipment, patient and equipment supports, component parts, and...

  9. Noise Studies of Externally Dispersed Interferometry for Doppler Velocimetry

    International Nuclear Information System (INIS)

    Erskine, D J; Edelstein, J; Lloyd, J; Muirhead, P

    2006-01-01

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. Both regular and high-frequency spectral components can be recovered from the data--the moire component carries additional information that increases the signal to noise for velocimetry and spectroscopy. Here we present simulations and theoretical studies of the photon limited Doppler velocity noise in an EDI. We used a model spectrum of a 1600K temperature star. For several rotational blurring velocities 0, 7.5, 15 and 25 km/s we calculated the dimensionless Doppler quality index (Q) versus wavenumber v. This is the normalized RMS of the derivative of the spectrum and is proportional to the photon-limited Doppler signal to noise ratio

  10. Applications of Doppler in the first trimester

    International Nuclear Information System (INIS)

    Taylor, K.J.W.; Ramirez, B.; Grannum, P.

    1986-01-01

    Fifty patients have been studied by duplex Doppler US imaging in the first trimester. In normal gestations, luteal flow, characterized by a low pulsatility index (PI), can be seen in at least one ovary. Failure to detect luteal flow indicates a nonviable pregnancy. Six ectopic pregnancies demonstrated luteal flow and extrauterine heartbeat, detected by Doppler US. High PI values in the uterine artery are seen in the first trimester. Low PI values in the uterine arteries were found in patients with trophoblastic disease

  11. Christian Andreas Doppler--the man and his legacy.

    Science.gov (United States)

    Coman, I M

    2005-01-01

    Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.

  12. Effects of excretory/secretory products from Anisakis simplex (Nematoda) on immune gene expression in rainbow trout (Oncorhynchus mykiss)

    DEFF Research Database (Denmark)

    Bahlool, Qusay Zuhair Mohammad; Skovgaard, Alf; Kania, Per Walter

    2013-01-01

    Excretory/secretory (ES) products are molecules produced by parasitic nematodes, including larval Anisakis simplex, a parasite occurring in numerous marine fish hosts. The effects of these substances on host physiology have not been fully described. The present work elucidates the influence of ES...... substances on the fish immune system by measuring immune gene expression in spleen and liver of rainbow trout (Oncorhynchus mykiss) injected intraperitoneally with ES products isolated from A. simplex third stage larvae. The overall gene expression profile of exposed fish showed a generalized down....... This type of hydrolytic enzyme activity may play a role in nematode penetration of host tissue. In addition, based on the notion that A. simplex ES products may have an immune-depressive effect (by minimizing immune gene expression) it could also be suggested that worm enzymes directly target host immune...

  13. Fetal Cardiac Doppler Signal Processing Techniques: Challenges and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Saeed Abdulrahman Alnuaimi

    2017-12-01

    Full Text Available The fetal Doppler Ultrasound (DUS is commonly used for monitoring fetal heart rate and can also be used for identifying the event timings of fetal cardiac valve motions. In early-stage fetuses, the detected Doppler signal suffers from noise and signal loss due to the fetal movements and changing fetal location during the measurement procedure. The fetal cardiac intervals, which can be estimated by measuring the fetal cardiac event timings, are the most important markers of fetal development and well-being. To advance DUS-based fetal monitoring methods, several powerful and well-advanced signal processing and machine learning methods have recently been developed. This review provides an overview of the existing techniques used in fetal cardiac activity monitoring and a comprehensive survey on fetal cardiac Doppler signal processing frameworks. The review is structured with a focus on their shortcomings and advantages, which helps in understanding fetal Doppler cardiogram signal processing methods and the related Doppler signal analysis procedures by providing valuable clinical information. Finally, a set of recommendations are suggested for future research directions and the use of fetal cardiac Doppler signal analysis, processing, and modeling to address the underlying challenges.

  14. Doppler sonographic evaluation of ophthalmic arterial flow pattern in hypertensive patients

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Young Goo

    1994-01-01

    To compare the Doppler velocity waveform pattern of ophthalmic artery of hypertensive patients with that of normotensive subjects. Doppler velocity waveform was obtained from ophthalmic artery in 45 hypertensive patients and 60 normotensive subjects. Both hypertensives and normotensive subjects were classified according to age into those younger than and those older than 45 years. Doppler indices(pulsatility index(PI), resistance index(RI), the first systolic peak/the second systolic peak(S1/S2), the first systolic peak/diastolic peak(S1/D)) measured in hypertensive patients were compared with normotensive subjects. Among the various doppler indices, only S1/S2 showed significant difference(P < 0.05) between the hypertensive patients and normotensive subjects younger than 45 years. Doppler velocity waveform of hypertensive patients older than 45 years showed no significant difference from that of normotensive subjects with corresponding age. Doppler velocity waveform of ophthalmic artery in hypertensive patients younger than 45 years shows pattern with S2 higher than that of normotensive subjects. High S2 component(reflective-wave) may represent increased vascular impedance due to vasococonstriction of retinal arterioles in hypertensive patients

  15. Magnetic angioresonance of the carotid artery: correlation with color Doppler ultrasound

    International Nuclear Information System (INIS)

    Cotilla, J.; Miralles, M.; Cairols, M.C.; Dolz, J.L.; Vilanova, J.C.; Capdevila, A.

    1998-01-01

    To determine the value of magnetic angioresonance (MAR) in grading carotid stenosis, comparing it with color Doppler and intraarterial digital subtraction angiography (IADSA). A comparative study using color Doppler and MAR was carried out in 84 patients with coratid lesions. Fifty-two of the patients underwent angiographic study as well. The comparison of MAR versus arteriography in discriminating stenosis of more than 70%, expressed in terms of sensitivity specificity, overall precision and the kappa concordance index, gave values of 87.2, 90.8, 89.4 and 0.78%, respectively. When MAR was compared with color Doppler, the results were 86.8, 85.9, 86.3 and 0.72%, respectively. The results of the comparison between color Doppler and arteriography were 82.2, 86.2, 84.6 and 0.68%, respectively. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability of this imaging technique. (Author) 29 refs

  16. Use of TRIGA-pulsed irradiations for high-temperature Doppler measurements

    Energy Technology Data Exchange (ETDEWEB)

    Foell, W K; Cashwell, R J; Bhattacharyya, S K [Argonne National Laboratory, Argonne, IL (United States); Russell, G J [Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1974-07-01

    Conventional activation and reactivity measurements of the nuclear Doppler Effect have been limited to temperatures of about 2000{sup o}K because of problems with furnace equipment. There is a need for Doppler data at higher temperatures for design of reactors and analysis of reactor accidents. To fill this need, a novel technique using pulsed-mode operation of a TRIGA reactor has been developed at the University of Wisconsin. This new method, the Pulsed Activation Doppler (PAD) technique, has been used successfully for high temperature Doppler measurements of UO{sub 2} fuel pellets. In the PAD technique, UO{sub 2} test pellets were doped with varying amounts of U-235, with fissile enrichments varying from 0.22% to 12% by weight. The pellets were encapsulated in individual irradiation cells and electrically preheated to predetermined temperatures. Pyrofoam-graphite heaters were used to give preheat temperatures of up to 1720 deg. K. The cells were then positioned in the University of Wisconsin TRIGA reactor core and pulse-irradiated. During the rapid irradiation, adiabatic fission energy deposition occurred in the pellets and very high temperatures (over 3115 deg, K) were attained. Corresponding resonance neutron captures occurred at the elevated temperatures. The Doppler Ratio was deduced from the gamma activities of the Np-239 in the heated and unheated reference pellets. UO{sub 2} pellets of two nominal diameters, 210 mils (a surface-to-mass ratio, s/m = 1.1 cm{sup 2} /gm) and 360 mils (s/m = 0.63 cm{sup 2}/gm), were used for the experiments. For the 210 mil diameter pellets there was very good agreement between experimental results and Doppler ratios predicted both from extrapolations of the Hellstrand low-temperature resonance integral correlations and from GAROL calculations. Significantly, the agreement was good even for those pellets which experienced extensive melting. For the 360 mil diameter pellets the theoretical predictions were 10-15% lower than

  17. Doppler ultrasound scan during normal gestation: umbilical circulation

    International Nuclear Information System (INIS)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J.

    2002-01-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs

  18. Dispersed single-phase-step Michelson interferometer for Doppler imaging using sunlight.

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian

    2012-09-15

    A Michelson interferometer is dispersed with a fiber array-fed spectrograph, providing 59 Doppler sensing channels using sunlight in the 510-570 nm wavelength region. The interferometer operates at a single-phase-step mode, which is particularly advantageous in multiplexing and data processing compared to the phase-stepping mode of other interferometer spectrometer instruments. Spectral templates are prepared using a standard solar spectrum and simulated interferometer modulations, such that the correlation function with a measured 1D spectrum determines the Doppler shift. Doppler imaging of a rotating cylinder is demonstrated. The average Doppler sensitivity is ~12 m/s, with some channels reaching ~5 m/s.

  19. An elementary approach to the gravitational Doppler shift

    International Nuclear Information System (INIS)

    Wörner, C H; Rojas, Roberto

    2017-01-01

    In college physics courses, treatment of the Doppler effect is usually done far from the first introduction to kinematics. This paper aims to apply a graphical treatment to describe the gravitational redshift, by considering the Doppler effect in two accelerated reference frames and exercising the equivalence principle. This approach seems appropriate to discuss with beginner students and could serve to enrich the didactic processes. (paper)

  20. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  1. Superimposed noninterfering probes to extend the capabilities of phase Doppler anemometry.

    Science.gov (United States)

    Onofri, Fabrice; Lenoble, Anne; Radev, Stefan

    2002-06-20

    We propose using multiple superimposed noninterfering probes (SNIPs) of the same wavelength but different beam angles to extend the capabilities of phase Doppler anemometry. When a particle is moving in a SNIP the Doppler signals that are produced exhibit multiple Doppler frequencies and phase shifts. The resolution of the measurements of particle size (i.e., by fringe spacing and Doppler frequency) increases with beam angle. Then, with the solution proposed, even with only two detectors several measurements of size can be obtained for the same particle with increasing resolution if we consider higher frequencies in the signal. Several optical solutions to produce SNIPs as well as a signal-processing algorithm to treat the multiple-frequency Doppler signals are proposed. Experimental validations of the sizing of spherical and cylindrical particles demonstrate the applicability of this technique for particle measurement. We believe that this new technique can be of great interest when high resolution of size, velocity, and even refractive index is required.

  2. Correlation between Spectral Index and Doppler Factor for a ...

    Indian Academy of Sciences (India)

    Abstract. Relativistic beaming effect is important for blazars. In a very recent work, γ-ray Doppler factors were calculated for a sample of Fermi blazars (Fan et al. 2013). In this work, we investigated the correlation between the Doppler factor and the effective spectral index, αOX, and found an anticorrelation between them.

  3. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  4. Application of coincidence Doppler-broadening spectroscopy to different carbon phases

    International Nuclear Information System (INIS)

    Ito, Y.; Djourelov, N.; Suzuki, T.; Kondo, K.; Ito, Y.; Shantarovich, V.; Onoe, J.

    2004-01-01

    Coincidence Doppler-broadening spectroscopy was applied to C60 and C70 fullerenes and other carbon phases, such as nanotubes and graphites. Remarkable differences were observed in the Doppler-broadening of the positron annihilation γ-rays in these materials, which reflect the different densities distribution of the momentum for electrons annihilated with positrons. This would be caused by the different composition of the π and σ electrons in annihilation with positrons. This result shows the sensitivity of the coincidence Doppler-broadening method to determine the density distribution of electrons sampled by positrons. (orig.)

  5. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    Science.gov (United States)

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  6. Comparative analysis of pulsed doppler ultrasonography of portal vein vs indirect photography

    International Nuclear Information System (INIS)

    Chang, Jae Chun; Kwon, Huck Po; Hwang, Mi Soo; Kim, Sun Youn; Park, Bok Hwan; Lee, Hyun Ju; Kim, Hong Jin

    1990-01-01

    There are some limitation of interpretation in indirect photography via superior mesenteric artery. In order to supplement and predict indirect photography, we compared indirect photographic findings with pulsed doppler flowmetry in 38 hepatobiliary patients, and the results were as follow: 1. In case of normal main portal vein(MPV) filling, Pulsed Doppler always showed antegrade, continuous parabolic wave form and cases of abnormal MPV filling, showed unusual wave form and flow direction. 2. In normal filling case of proximal right portal vein, Pulsed Doppler almost showed normal continuous parabolic wave form but in normal filling cases of proximal left portal vein, occasionally showed undulating wave form. 3. In each side proximal portal vein abnormal filling case, we could observe abnormal doppler wave form and could obtain additional information using doppler wave form. 4. Mean portal flow velocity was significantly increased in higher photography grade(p=0.01) and congestion index was significantly decreased in higher photography grade(p=0.01). 5. We concluded that doppler ultrasonography could supplement incomplete indirect photography

  7. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2009-12-15

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  8. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    International Nuclear Information System (INIS)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee; Kim, Sam Soo

    2009-01-01

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  9. Synthesis and evaluation of nanoglobule-cystamine-(Gd-DO3A, a biodegradable nanosized magnetic resonance contrast agent for dynamic contrast-enhanced magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Rongzuo Xu

    2010-09-01

    Full Text Available Rongzuo Xu1, Todd Lyle Kaneshiro1, Eun-Kee Jeong2, Dennis L Parker2, Zheng-Rong Lu31Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, USA; 2Department of Radiology, University of Utah, Salt Lake City, UT, USA; 3Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USAAbstract: Dynamic contrast-enhanced magnetic resonance imaging has been recently shown to be effective for diagnostic urography. High-resolution urographic images can be acquired with T1 contrast agents for the kidney and urinary tract with minimal noise in the abdomen. Currently, clinical contrast agents are low molecular weight agents and can rapidly extravasate from blood circulation, leading to slow contrast agent elimination through kidney and consequently providing limited contrast enhancement in urinary tract. In this study, a new biodegradable macromolecular contrast agent, nanoglobule-G4-cystamine-(Gd-DO3A, was prepared by conjugating Gd-DO3A chelates on the surface of a generation 4 nanoglobule, poly-l-lysine octa(3-aminopropylsilsesquioxane dendrimer, via a disulfide spacer, where the carrier had a precisely defined nanosize that is far smaller than the renal filtration threshold. The in vivo contrast enhancement and dynamic imaging of the urinary tract of the agent was evaluated in nude mice using a low molecular weight agent Gd(DTPA-BMA as a control. The agent eliminated rapidly from blood circulation and accumulated more abundantly in urinary tract than Gd(DTPA-BMA. The fast elimination kinetics is ideal for functional evaluation of the kidneys. The morphology of the kidneys and urinary tract was better visualized by the biodegradable nanoglobular contrast agent than Gd(DTPA-BMA. The agent also resulted in low liver contrast enhancement, indicating low nonspecific tissue deposition. These features render the G4 nanoglobule-cystamine-(Gd-DO3A conjugate a promising contrast agent for magnetic

  10. Moving Target Detection With Compact Laser Doppler Radar

    Science.gov (United States)

    Sepp, G.; Breining, A.; Eisfeld, W.; Knopp, R.; Lill, E.; Wagner, D.

    1989-12-01

    This paper describes an experimental integrated optronic system for detection and tracking of moving objects. The system is based on a CO2 waveguide laser Doppler ra-dar with homodyne receiver and galvanometer mirror beam scanner. A "hot spot" seeker consisting of a thermal imager with image processor transmits the coordinates of IR-emitting, i.e. potentially powered, objects to the laser radar scanner. The scanner addresses these "hot" locations operating in a large field-of-view (FOV) random ac-cess mode. Hot spots exhibiting a Doppler shifted laser signal are indicated in the thermal image by velocity-to-colour encoded markers. After switching to a small FOV scanning mode, the laser Doppler radar is used to track fast moving objects. Labora-tory and field experiments with moving objects including rotating discs, automobiles and missiles are described.

  11. Three-dimensional laser cooling at the Doppler limit

    Science.gov (United States)

    Chang, R.; Hoendervanger, A. L.; Bouton, Q.; Fang, Y.; Klafka, T.; Audo, K.; Aspect, A.; Westbrook, C. I.; Clément, D.

    2014-12-01

    Many predictions of Doppler-cooling theory of two-level atoms have never been verified in a three-dimensional geometry, including the celebrated minimum achievable temperature ℏ Γ /2 kB , where Γ is the transition linewidth. Here we show that, despite their degenerate level structure, we can use helium-4 atoms to achieve a situation in which these predictions can be verified. We make measurements of atomic temperatures, magneto-optical trap sizes, and the sensitivity of optical molasses to a power imbalance in the laser beams, finding excellent agreement with Doppler theory. We show that the special properties of helium, particularly its small mass and narrow transition linewidth, prevent effective sub-Doppler cooling with red-detuned optical molasses. This discussion can be generalized to identify when a given species is likely to be subject to the same limitation.

  12. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  13. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  14. [The value of Doppler sonography in the detection of fetal hypoxia].

    Science.gov (United States)

    Aranyosi, János; Zatik, János; Juhász, A Gábor; Fülesdi, Béla; Major, Tamás

    2002-10-27

    Doppler ultrasound has become a part of routine antenatal fetal surveillance during the past two decades. It provides insight into the utero-placental and fetal arterial, venous circulation non-invasively. Doppler examination has a key role in the detection of hypoxic risk since abnormal blood flow patterns can be demonstrated before the clinical manifestation of fetal disorder. Doppler velocimetry facilitates judgment in the diagnosis, monitoring fetal well-being during pregnancy and labor, scheduling antenatal tests and timing delivery. Authors review the effects of chronic and acute hypoxia on fetal hemodynamics. On the basis of the present knowledge and experience a brief summary is given about the role of Doppler velocimetry in the early detection of hypoxic fetal jeopardy during pregnancy and labor.

  15. Doppler Centroid Estimation for Airborne SAR Supported by POS and DEM

    Directory of Open Access Journals (Sweden)

    CHENG Chunquan

    2015-05-01

    Full Text Available It is difficult to estimate the Doppler frequency and modulating rate for airborne SAR by using traditional vector method due to instable flight and complex terrain. In this paper, it is qualitatively analyzed that the impacts of POS, DEM and their errors on airborne SAR Doppler parameters. Then an innovative vector method is presented based on the range-coplanarity equation to estimate the Doppler centroid taking the POS and DEM as auxiliary data. The effectiveness of the proposed method is validated and analyzed via the simulation experiments. The theoretical analysis and experimental results show that the method can be used to estimate the Doppler centroid with high accuracy even in the cases of high relief, instable flight, and large squint SAR.

  16. Doppler velocity measurements from large and small arteries of mice

    Science.gov (United States)

    Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.

    2011-01-01

    With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013

  17. Pulsed-wave transmitral Doppler do not diagnose moderate acute rejection after heart transplantation

    NARCIS (Netherlands)

    Mannaerts, H. F.; Simoons, M. L.; Balk, A. H.; Tijssen, J.; van der Borden, S. G.; Zondervan, P. E.; Mochtar, B.; Weimar, W.; Roelandt, J. R.

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  18. PULSED-WAVE TRANSMITRAL DOPPLER DO NOT DIAGNOSE MODERATE ACUTE REJECTION AFTER HEART-TRANSPLANTATION

    NARCIS (Netherlands)

    MANNAERTS, HF; SIMOONS, ML; BALK, AH; TIJSSEN, J; VANDERBORDEN, SG; ZONDERVAN, PE; MOCHTAR, B; WEIMAR, W; ROELANDT, [No Value

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  19. CT urography of urinary diversions with enhanced CT digital radiography: preliminary experience.

    Science.gov (United States)

    Sudakoff, Gary S; Guralnick, Michael; Langenstroer, Peter; Foley, W Dennis; Cihlar, Krista L; Shakespear, Jonathan S; See, William A

    2005-01-01

    The purpose of this study was to determine if 3D-rendered CT urography (CTU) depicts both normal and abnormal findings in patients with urinary diversions and if the addition of contrast-enhanced CT digital radiography (CTDR) improves opacification of the urinary collecting system. Thirty CTU and contrast-enhanced CTDR examinations were performed in 24 patients who underwent cystectomy for bladder cancer. Indications for evaluation included hematuria, tumor surveillance, or suspected diversion malfunction. All examinations were evaluated without knowledge of the stage or grade of a patient's tumor and were compared with the clinical records. Opacification of the urinary collecting system was evaluated with 3D CTU alone, contrast-enhanced CTDR alone, and combined CTU and CTDR. Nine abnormalities were identified including distal ureteral strictures (n = 4), vascular compression of the mid left ureter (n = 1), scarring of the mid right pole infundibulum (n = 1), bilateral hydronephrosis and hydroureter (n = 1), urinary reservoir calculus (n = 1), and tumor recurrence invading the afferent limb of the neobladder (n = 1). Eight of the nine detected abnormalities were surgically or pathologically confirmed. All abnormalities were identified on all three imaging techniques but were best seen on 3D CTU and enhanced CTDR images. Incomplete opacification of the urinary collecting system occurred in 17 patients with CTU alone, 12 patients with contrast-enhanced CTDR alone, and nine patients with combined CTU and contrast-enhanced CTDR. Compared with CTU alone, the combined technique of 3D CTU and contrast-enhanced CTDR improved opacification by a statistically significant difference (p = 0.037). CTU with 3D rendering can accurately depict both normal and abnormal postoperative findings in patients with urinary diversions. Adding enhanced CTDR can improve visualization of the urinary collecting system.

  20. Evaluation of multidetector computed tomography urography and ultrasonography for diagnosing bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Knox, M.K. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Cowan, N.C. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Department of Radiology, Churchill Hospital, Oxford OX3 7LJ (United Kingdom)], E-mail: nigel.cowan@nds.ox.ac.uk; Rivers-Bowerman, M.D.; Turney, B.W. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom)

    2008-12-15

    Aim: To evaluate and compare the diagnostic accuracy of multidetector computed tomography urography (CTU) and ultrasonography (US) for diagnosing bladder cancer. Materials and methods: A consecutive series of 143 patients over 40-years of age, presenting with macroscopic haematuria and without urinary tract infection underwent same-day CTU, US, and flexible cystoscopy. CTU and US were independently rated on a five-point scale for the presence of bladder cancer without knowledge of the reference standard of flexible or rigid cystoscopy and/or biopsy results. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analysis and likelihood ratios. Results: For CTU, a rating of 5 (definitely tumour) was highly specific for bladder cancer (96.5%, 95%CI: 91.3-99%), effectively confirming diagnosis (positive likelihood ratio 25.6, 95%CI: 9.7-67.4). For US, specificity was also high (94.7%, 95%CI: 88.9-98%) with a positive likelihood ratio of 13.1 (95%CI: 5.8-29.6). Sensitivity at this rating was substantially higher for CTU (89.7%, 95%CI: 72.7-97.8%) than US (69%, 95%CI: 49.2-84.7%). Standardized partial area (A{sub z}) under the ROC curve between 95-100% specificity, representing the average sensitivity in this range, was significantly greater (0.88 versus 0.61, p < 0.05) for CTU than US. Conclusion: The specificities of CTU and US for the diagnosis of bladder cancer were similar, but CTU was more sensitive. Although the sensitivity of CTU was not high enough to replace flexible cystoscopy in the diagnostic pathway, the high specificity enables direct referral to rigid cystoscopy, bypassing flexible cystoscopy and expediting diagnosis and treatment in those patients testing positive.

  1. Evaluation of multidetector computed tomography urography and ultrasonography for diagnosing bladder cancer

    International Nuclear Information System (INIS)

    Knox, M.K.; Cowan, N.C.; Rivers-Bowerman, M.D.; Turney, B.W.

    2008-01-01

    Aim: To evaluate and compare the diagnostic accuracy of multidetector computed tomography urography (CTU) and ultrasonography (US) for diagnosing bladder cancer. Materials and methods: A consecutive series of 143 patients over 40-years of age, presenting with macroscopic haematuria and without urinary tract infection underwent same-day CTU, US, and flexible cystoscopy. CTU and US were independently rated on a five-point scale for the presence of bladder cancer without knowledge of the reference standard of flexible or rigid cystoscopy and/or biopsy results. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analysis and likelihood ratios. Results: For CTU, a rating of 5 (definitely tumour) was highly specific for bladder cancer (96.5%, 95%CI: 91.3-99%), effectively confirming diagnosis (positive likelihood ratio 25.6, 95%CI: 9.7-67.4). For US, specificity was also high (94.7%, 95%CI: 88.9-98%) with a positive likelihood ratio of 13.1 (95%CI: 5.8-29.6). Sensitivity at this rating was substantially higher for CTU (89.7%, 95%CI: 72.7-97.8%) than US (69%, 95%CI: 49.2-84.7%). Standardized partial area (A z ) under the ROC curve between 95-100% specificity, representing the average sensitivity in this range, was significantly greater (0.88 versus 0.61, p < 0.05) for CTU than US. Conclusion: The specificities of CTU and US for the diagnosis of bladder cancer were similar, but CTU was more sensitive. Although the sensitivity of CTU was not high enough to replace flexible cystoscopy in the diagnostic pathway, the high specificity enables direct referral to rigid cystoscopy, bypassing flexible cystoscopy and expediting diagnosis and treatment in those patients testing positive

  2. Compressive sensing for high resolution profiles with enhanced Doppler performance

    NARCIS (Netherlands)

    Anitori, L.; Hoogeboom, P.; Chevalier, F. Le; Otten, M.P.G.

    2012-01-01

    In this paper we demonstrate how Compressive Sensing (CS) can be used in pulse-Doppler radars to improve the Doppler performance while preserving range resolution. We investigate here two types of stepped frequency waveforms, the coherent frequency bursts and successive frequency ramps, which can be

  3. Study on Zero-Doppler Centroid Control for GEO SAR Ground Observation

    Directory of Open Access Journals (Sweden)

    Yicheng Jiang

    2014-01-01

    Full Text Available In geosynchronous Earth orbit SAR (GEO SAR, Doppler centroid compensation is a key step for imaging process, which could be performed by the attitude steering of a satellite platform. However, this zero-Doppler centroid control method does not work well when the look angle of radar is out of an expected range. This paper primarily analyzes the Doppler properties of GEO SAR in the Earth rectangular coordinate. Then, according to the actual conditions of the GEO SAR ground observation, the effective range is presented by the minimum and maximum possible look angles which are directly related to the orbital parameters. Based on the vector analysis, a new approach for zero-Doppler centroid control in GEO SAR, performing the attitude steering by a combination of pitch and roll rotation, is put forward. This approach, considering the Earth’s rotation and elliptical orbit effects, can accurately reduce the residual Doppler centroid. All the simulation results verify the correctness of the range of look angle and the proposed steering method.

  4. Precise Doppler shift compensation in the hipposiderid bat, Hipposideros armiger.

    Science.gov (United States)

    Schoeppler, Diana; Schnitzler, Hans-Ulrich; Denzinger, Annette

    2018-03-15

    Bats of the Rhinolophidae and Hipposideridae families, and Pteronotus parnellii, compensate for Doppler shifts generated by their own flight movement. They adjust their call frequency such that the frequency of echoes coming from ahead fall in a specialized frequency range of the hearing system, the auditory fovea, to evaluate amplitude and frequency modulations in echoes from fluttering prey. Some studies in hipposiderids have suggested a less sophisticated or incomplete Doppler shift compensation. To investigate the precision of Doppler shift compensation in Hipposideros armiger, we recorded the echolocation and flight behaviour of bats flying to a grid, reconstructed the flight path, measured the flight speed, calculated the echo frequency, and compared it with the resting frequency prior to each flight. Within each flight, the average echo frequency was kept constant with a standard deviation of 110 Hz, independent of the flight speed. The resting and reference frequency were coupled with an offset of 80 Hz; however, they varied slightly from flight to flight. The precision of Doppler shift compensation and the offset were similar to that seen in Rhinolophidae and P. parnellii. The described frequency variations may explain why it has been assumed that Doppler shift compensation in hipposiderids is incomplete.

  5. Renal Power Doppler Ultrasonographic Evaluation of Children With Acute Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Ali Pahlusi

    2011-10-01

    Full Text Available Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.82.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  6. Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer

    International Nuclear Information System (INIS)

    Alexander, Archie A.; Palazzo, Juan P.; Ahmad, Neelofur R.; Liu, J.-B.; Forsberg, Flemming; Marks, John

    1996-01-01

    Purpose: To correlate the endosonographic and color Doppler flow imaging alterations observed in irradiated rectal cancers with the pathologic features of radiation response, and to evaluate the potential impact of altered blood flow on the integrity of the surgical anastamosis. Methods and Materials: Endosonography with color and pulsed wave Doppler was performed on 20 rectal cancer masses before and after high dose preoperative radiation (XRT). Pre- and post-XRT observations included comparing alterations in tumor size, sonographic echotexture, color Doppler flow, and pulsatility indices. Comparisons were made with pathologic findings in the irradiated specimens and with the incidence of anastomotic failure. Results: Compared to pre-XRT observations, irradiated rectal cancers decreased in size and became either mixed in echogenicity with less apparent color Doppler flow (16 of 20) or unchanged in color Doppler flow and echotexture (4 of 20). Those with less flow (16 of 20) were imaged later (mean = 90.2 ± 12.1 days) than those without change in color Doppler flow (mean = 21.7 ± 2.7 days). Pathologically, the group of four without change in color Doppler signal had features of acute inflammation which were not observed in 16 of 20 imaged later. Based on pulsatility index measurements, both high and low resistance vessels were detected and confirmed by immunohistochemical staining, and features of postradiation obliterative vasculitis were observed. Only one primary anastomosis in 14 patients with decreased flow failed. Conclusions: The sonographic and color Doppler flow imaging alterations observed within irradiated rectal cancer correlated with changes of postradiation obliterative vasculitis. The apparent diminished local blood flow within high and low resistance vessels post-XRT did not result in an increased incidence of anastomotic failures

  7. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  8. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  9. Development of indirect sandwich ELISA for determination of excretory-secretory antigens of Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Libertad Alzamora-Gonzales

    2016-05-01

    Full Text Available Fasciolosis is a cosmopolitan parasitosis medical-veterinary importance caused by Fasciola hepatica, which affects sheep, goats and cattle; and it affects man accidentally causing an epidemic-endemic infection difficult to diagnose. The aim was to develop an indirect sandwich ELISA with 3 antibodies for detecting excretory-secretory antigens of Fasciola hepatica (ESFh. For the development of indirect sandwich ELISA were used, as capture antibody, mouse polyclonal antibodies anti ESFh and polyclonal antibodies rabbit anti-ESFh as detection antibody, at the concentrations of 10 and 5 µg/mL respectively. The conjugate used was mouse monoclonal anti- total immunoglobulins rabbit linked to peroxidase (1/1000. Were analized 31 sheep fecal samples, and the results were compared with those obtained by direct coproparasitological examination (DC and counterimmunoelectrophoresis (CIEP. The detection limit obtained for indirect sandwich ELISA was 100 ng/mL. The test had a 100% sensitivity, 96.6% specificity, positive and negative predictive values of 50% and 96.6% respectively, in relation to DC test. Comparing with CIEP the specificity obtained for indirect sandwich ELISA was 93.5% and a negative predictive value of 100%. We concluded that indirect sandwich ELISA designed is able to detect metabolic antigens in ovine feces samples and can be used for Fasciola hepatica diagnosis.

  10. TORSION TESTIS : ROLE OF COLOR DOPPLER : A STUDY OF 50 CASES

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND: T orsion testis is one of the catast r ophic conditions in children and young a d u lts. Traditionally the diagnosis was made clinical presentation and suspicion. Critical decision making is essential to save the testis . OBJECTIVE: To study the usefu lness and efficacy of Doppler ultrasound in correctly diagnosing acute scrotal conditions in children and young adults to save the testis and to avoid negative explorations. METHODS: Over a period of two years 50 patients with acute scrotum were admitted i n general surgery department who underwent Doppler ultrasound scrotum and its efficacy in correctly diagnosing the pathology was analysed. RESULTS: 50 patients with age group <25 years were included in study. Scrotal pain was the most frequent presenting s ymptom of acute scrotum (98% followed by Swelling of the hemiscrolum on the involved side present in 86% of the patients. Doppler ultrasound showed torsion of testis in 18 patients. On Scrotal exploration, torsion of spermatic cord was confirmed in 16 pat ients, one patient had torsion of appendix of testis and the other had Epididymo - orchitis. Thus the sensitivity and specificity of Doppler ultrasonography for testicular torsion was 86.9% and 92.6% respectively. 2 patients with equivocal Doppler findings, but strong clinical suspicion of testicular torsion were explored, and testis was found to be torsed in both two patients. Doppler ultrasonography showed Epididymo - orchitis in 22 patients, torsion of testicular appendage in 2 patients, Idiopathic scrotal edema in one, and in 5 pts no significant pathology found. All twenty patients of epididymo - orchitis, two patients of torsion of testicular appendage, and one patient of idiopathic scrotal edema were managed conservatively. At three weeks follow up, all th e patients were free of symptoms. The sensitivity and specificity of Doppler ultrasonography for epididymo - orchitis was 95% and 100% respectively. CONCLUSIONS: color

  11. High-frequency Doppler ultrasound transducer for the peripheral circulatory system

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Youngmin; Yang, Jeongwon; Kang, Uk; Kim, Guanghoon [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2011-12-15

    A Doppler ultrasound transducer was designed and implemented to measure the blood flow velocity in tiny vessels near the skin of hands or feet. The geometric parameters of the transducer for defining the observation volume were derived and implemented with an acoustic window made of polystyrene. The observation volume designed in this study was located 6.5 mm from the transducer, which was comparable to the value predicted geometrically. The two-way insertion loss of the transducer was -11.3 dB on ultrasound frequency of 20 MHz, and the 3-dB bandwidth was approximately 2 MHz. In addition, the Doppler shift in the frequency measured by using a Doppler device composed of the transducer and a Doppler signal processing unit was proportional to the flow velocity generated by a homemade flowing system. Finally, we concluded that the transducer could be applied to measure the blood flow velocity in hands or feet.

  12. High-frequency Doppler ultrasound transducer for the peripheral circulatory system

    International Nuclear Information System (INIS)

    Bae, Youngmin; Yang, Jeongwon; Kang, Uk; Kim, Guanghoon

    2011-01-01

    A Doppler ultrasound transducer was designed and implemented to measure the blood flow velocity in tiny vessels near the skin of hands or feet. The geometric parameters of the transducer for defining the observation volume were derived and implemented with an acoustic window made of polystyrene. The observation volume designed in this study was located 6.5 mm from the transducer, which was comparable to the value predicted geometrically. The two-way insertion loss of the transducer was -11.3 dB on ultrasound frequency of 20 MHz, and the 3-dB bandwidth was approximately 2 MHz. In addition, the Doppler shift in the frequency measured by using a Doppler device composed of the transducer and a Doppler signal processing unit was proportional to the flow velocity generated by a homemade flowing system. Finally, we concluded that the transducer could be applied to measure the blood flow velocity in hands or feet.

  13. Proposed protocols for peripheral and renal Doppler

    International Nuclear Information System (INIS)

    Fonseca Portuguez, Adriana

    2009-01-01

    A literature review was performed in order to prepare a summary of the important concepts of Doppler and applications in peripheral vascular evaluation and renal. The normal characteristics are summarized and explained in each vascular system and diagnostic criteria of the disorders frequently encountered in practice. Requested more studies have been identified and proposed protocols and report sheets have been developed to standardize the methodology of realization of several Doppler studies. The variability between operators has been treated to reduce as much as possible and follow-up studies have provided in patients who need. (author) [es

  14. Doppler broadening of cross sections

    International Nuclear Information System (INIS)

    Buckler, P.A.C.; Pull, I.C.

    1962-12-01

    Expressions for temperature dependent cross-sections in terms of resonance parameters are obtained, involving generalisations of the conventional Doppler functions, ψ and φ. Descriptions of Fortran sub-routines, which calculate broadened cross-sections in accordance with the derived formulae, are included. (author)

  15. A simplified study of trans-mitral Doppler patterns

    Directory of Open Access Journals (Sweden)

    Thomas George

    2008-11-01

    Full Text Available Abstract Background Trans-mitral Doppler produces complex patterns with a great deal of variability. There are several confusing numerical measures and indices to study these patterns. However trans-mitral Doppler produces readymade data visualization by pattern generation which could be interpreted by pattern analysis. By following a systematic approach we could create an order and use this tool to study cardiac function. Presentation of the hypothesis In this new approach we eliminate the variables and apply pattern recognition as the main criterion of study. Proper terminologies are also devised to avoid confusion. In this way we can get some meaningful information. Testing the hypothesis Trans-mitral Doppler should be seen as patterns rather than the amplitude. The hypothesis can be proven by logical deduction, extrapolation and elimination of variables. Trans-mitral flow is also analyzed vis-à-vis the Starling's Law applied to the left atrium. Implications of the hypothesis Trans-mitral Doppler patterns are not just useful for evaluating diastolic function. They are also useful to evaluate systolic function. By following this schema we could get useful diagnostic information and therapeutic options using simple pattern recognition with minimal measurements. This simplified but practical approach will be useful in day to day clinical practice and help in understanding cardiac function better. This will also standardize research and improve communication.

  16. Radar Micro-Doppler Feature Extraction Using the Singular Value Decomposition

    NARCIS (Netherlands)

    Wit, J.J.M. de; Harmanny, R.I.A.; Molchanov, P.

    2014-01-01

    Abstract—The micro-Doppler spectrogram depends on parts of a target moving and rotating in addition to the main body motion (e.g., spinning rotor blades) and is thus characteristic for the type of target. In this study, the micro-Doppler spectrogram is exploited to distinguish between birds and

  17. Acoustic doppler methods for remote measurements of ocean flows - a review

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The evolution of acoustic doppler methods for remote measurements of ocean flows has been briefly reviewed in historical perspective. Both Eulerian and profiling methods have been discussed. Although the first acoustic Doppler current meter has been...

  18. Developments in target micro-Doppler signatures analysis: radar imaging, ultrasound and through-the-wall radar

    OpenAIRE

    Clemente, C.; Balleri, A.; Woodbridge, K.; Soraghan, J. J.

    2013-01-01

    Target motions, other than the main bulk translation of the target, induce Doppler modulations around the main Doppler shift that form what is commonly called a target micro-Doppler signature. Radar micro-Doppler signatures are generally both target and action speci c and hence can be used to classify and recognise targets as well as to identify possible threats. In recent years, research into the use of micro-Doppler signatures for target classi cation to address many defence and security ch...

  19. Numerical stud of glare spot phase Doppler anemometry

    OpenAIRE

    Hespel , Camille; Ren , Kuan Fang; Gréhan , Gérard; Onofri , Fabrice

    2008-01-01

    International audience; The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The i...

  20. Transcranial Doppler ultrasound and cerebral angiography - alternative or complementary

    International Nuclear Information System (INIS)

    Bockenheimer, S.; Lorey, N.

    1985-01-01

    Transcranial Doppler ultrasound is a noninvasive method of recording the flow velocity of larger intracranial vessels. The impact on diagnosis of cerebravascular occlusive disease is not yet evaluated. We present 15 patients, age range 39-73 years, who suffered from completed stroke. The findings of transcranial Doppler ultrasound and of cerebral angiography are presented. The value of both methods in treatment strategy is discussed. (orig.) [de

  1. Predictable progressive Doppler deterioration in IUGR: does it really exist?

    LENUS (Irish Health Repository)

    Unterscheider, Julia

    2013-12-01

    An objective of the Prospective Observational Trial to Optimize Pediatric Health in IUGR (PORTO) study was to evaluate multivessel Doppler changes in a large cohort of intrauterine growth restriction (IUGR) fetuses to establish whether a predictable progressive sequence of Doppler deterioration exists and to correlate these Doppler findings with respective perinatal outcomes.

  2. The use ofDoppler velocitnetry ofthe utnbilical artery before 24 ...

    African Journals Online (AJOL)

    growth retardation with umbilical artery Doppler ultrasonography. BM] 1989; 298: 631-635. 12. Schulman H, Winter D, Farmakides G, er al. Pregnancy surveil- lance with Doppler velocimerry of the uterine and umbilical arter- ies. Am] Obstet Gyneco11989; 160: 192-196. 13. Hanrerry KP, Primrose MH, Neilson JP, Whittle MJ.

  3. [Doppler echocardiography of tricuspid insufficiency. Methods of quantification].

    Science.gov (United States)

    Loubeyre, C; Tribouilloy, C; Adam, M C; Mirode, A; Trojette, F; Lesbre, J P

    1994-01-01

    Evaluation of tricuspid incompetence has benefitted considerably from the development of Doppler ultrasound. In addition to direct analysis of the valves, which provides information about the mechanism involved, this method is able to provide an accurate evaluation, mainly through use of the Doppler mode. In addition to new criteria being evaluated (mainly the convergence zone of the regurgitant jet), some indices are recognised as good quantitative parameters: extension of the regurgitant jet into the right atrium, anterograde tricuspid flow, laminar nature of the regurgitant flow, analysis of the flow in the supra-hepatic veins, this is only semi-quantitative, since the calculation of the regurgitation fraction from the pulsed Doppler does not seem to be reliable; This accurate semi-quantitative evaluation is made possible by careful and consistent use of all the criteria available. The authors set out to discuss the value of the various evaluation criteria mentioned in the literature and try to define a practical approach.

  4. Contrast-enhanced power Doppler US in the characterization of renal masses

    International Nuclear Information System (INIS)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E.

    2000-01-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts [it

  5. Micro-Doppler Ambiguity Resolution for Wideband Terahertz Radar Using Intra-Pulse Interference.

    Science.gov (United States)

    Yang, Qi; Qin, Yuliang; Deng, Bin; Wang, Hongqiang; You, Peng

    2017-04-29

    Micro-Doppler, induced by micro-motion of targets, is an important characteristic of target recognition once extracted via parameter estimation methods. However, micro-Doppler is usually too significant to result in ambiguity in the terahertz band because of its relatively high carrier frequency. Thus, a micro-Doppler ambiguity resolution method for wideband terahertz radar using intra-pulse interference is proposed in this paper. The micro-Doppler can be reduced several dozen times its true value to avoid ambiguity through intra-pulse interference processing. The effectiveness of this method is proved by experiments based on a 0.22 THz wideband radar system, and its high estimation precision and excellent noise immunity are verified by Monte Carlo simulation.

  6. A Comprehensive Radial Velocity Error Budget for Next Generation Doppler Spectrometers

    Science.gov (United States)

    Halverson, Samuel; Ryan, Terrien; Mahadevan, Suvrath; Roy, Arpita; Bender, Chad; Stefansson, Guomundur Kari; Monson, Andrew; Levi, Eric; Hearty, Fred; Blake, Cullen; hide

    2016-01-01

    We describe a detailed radial velocity error budget for the NASA-NSF Extreme Precision Doppler Spectrometer instrument concept NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy). Such an instrument performance budget is a necessity for both identifying the variety of noise sources currently limiting Doppler measurements, and estimating the achievable performance of next generation exoplanet hunting Doppler spectrometers. For these instruments, no single source of instrumental error is expected to set the overall measurement floor. Rather, the overall instrumental measurement precision is set by the contribution of many individual error sources. We use a combination of numerical simulations, educated estimates based on published materials, extrapolations of physical models, results from laboratory measurements of spectroscopic subsystems, and informed upper limits for a variety of error sources to identify likely sources of systematic error and construct our global instrument performance error budget. While natively focused on the performance of the NEID instrument, this modular performance budget is immediately adaptable to a number of current and future instruments. Such an approach is an important step in charting a path towards improving Doppler measurement precisions to the levels necessary for discovering Earth-like planets.

  7. Carotid Doppler ultrasound findings in patients with left ventricular assist devices.

    Science.gov (United States)

    Cervini, Patrick; Park, Soon J; Shah, Dipesh K; Penev, Irina E; Lewis, Bradley D

    2010-12-01

    Left ventricular assist devices (LVADs) have been used to treat advanced heart failure refractory to medical management, as bridge therapy to myocardial recovery, as bridge therapy to cardiac transplantation, or as destination therapy for patients with unfavorable transplant candidacy. Neurologic complications are some of the most common and devastating complications in these patients. Preoperative carotid ultrasound is, therefore, a standard evaluation in patients at risk for cerebrovascular disease. Postoperative carotid artery Doppler sonography is performed in those patients with neurologic symptoms. It is likely, therefore, that sonographers, radiologists, and other physicians working in a center where LVADs are implanted will likely encounter a carotid artery Doppler study in this patient group. To our knowledge, the carotid Doppler findings in these patients have never been published. We review the Doppler ultrasound findings in 6 patients after LVAD insertion.

  8. Narrowing of electromagnetically induced transparency resonance in a Doppler-broadened medium

    International Nuclear Information System (INIS)

    Javan, Ali; Kocharovskaya, Olga; Lee Hwang; Scully, Marlan O.

    2002-01-01

    We derive an analytic expression for the linewidth of electromagnetically induced transparency (EIT) resonance in a Doppler-broadened system. It is shown here that for relatively low intensity of the driving field the EIT linewidth is proportional to the square root of intensity and is independent of the Doppler width, similar to the laser-induced line narrowing effect described by Feld and Javan. In the limit of high intensity we recover the usual power-broadening case where the EIT linewidth is proportional to the intensity and inversely proportional to the Doppler width

  9. Theoretical study of electromagnetically induced transparency in a five-level atom and application to Doppler-broadened and Doppler-free Rb atoms

    International Nuclear Information System (INIS)

    Bhattacharyya, Dipankar; Ray, Biswajit; Ghosh, Pradip N

    2007-01-01

    We report theoretical studies of a Λ-type five-level atomic system. The density matrix equations are set up and solved numerically to obtain the probe absorption line shape of Rb D 2 transitions for cold (Doppler-free) and room temperature (Doppler-broadened) atoms. Simulated spectra for Doppler-broadened systems lead to four velocity-selective dips along with an electromagnetic induced transparency (EIT) peak as observed earlier from the co-propagating pump-probe spectroscopy of Rb D 2 transitions. Effects of pump power and spontaneous decay rate from the upper levels on the simulated spectra are also studied. For cold atoms a very pronounced EIT peak is observed when the pump frequency is on resonance with one allowed transition. We find that lower pump power leads to a much sharper EIT signal in this case. A simulated dispersion curve shows a rapid variation of the refractive index that may lead to a sharp reduction of the group velocity of photons

  10. Ultrasonic intrusion sensor using the Doppler effect; Choonpa Doppler hoshiki shinnyu sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kani, H; Iwasaki, N; Goto, M [Nippon Soken, Inc., Tokyo (Japan); Tsuzuki, T; Nakamura, T [Denso Corp., Aichi (Japan)

    1997-10-01

    For vehicle anti-theft alarm systems which cope with vehicle and car component theft, EU initiated vehicle security regulations from Jan 1997. Also, the insurance industry has instituted the insurance certification of vehicle anti-theft alarm systems. We have developed an ultrasonic intrusion sensor using the doppler effect for vehicle anti-theft alarm systems specifically for these EU regulations and insurance certification. 2 refs., 7 figs., 1 tab.

  11. Imaging doppler lidar for wind turbine wake profiling

    Science.gov (United States)

    Bossert, David J.

    2015-11-19

    An imaging Doppler lidar (IDL) enables the measurement of the velocity distribution of a large volume, in parallel, and at high spatial resolution in the wake of a wind turbine. Because the IDL is non-scanning, it can be orders of magnitude faster than conventional coherent lidar approaches. Scattering can be obtained from naturally occurring aerosol particles. Furthermore, the wind velocity can be measured directly from Doppler shifts of the laser light, so the measurement can be accomplished at large standoff and at wide fields-of-view.

  12. Radar micro-Doppler of wind turbines : Simulation and analysis using rotating linear wire structures

    NARCIS (Netherlands)

    Krasnov, O.A.; Yarovoy, A.

    2015-01-01

    A simple electromagnetic model of wind-turbine's main structural elements as the linear wired structures is developed to simulate the temporal patterns of observed radar return Doppler spectra (micro-Doppler). Using the model, the micro-Doppler for different combinations of the turbines rotation

  13. Stage- and gender-specific proteomic analysis of Brugia malayi excretory-secretory products.

    Directory of Open Access Journals (Sweden)

    Yovany Moreno

    Full Text Available INTRODUCTION: While we lack a complete understanding of the molecular mechanisms by which parasites establish and achieve protection from host immune responses, it is accepted that many of these processes are mediated by products, primarily proteins, released from the parasite. Parasitic nematodes occur in different life stages and anatomical compartments within the host. Little is known about the composition and variability of products released at different developmental stages and their contribution to parasite survival and progression of the infection. METHODOLOGY/PRINCIPAL FINDINGS: To gain a deeper understanding on these aspects, we collected and analyzed through 1D-SDS PAGE and LC-MS/MS the Excretory-Secretory Products (ESP of adult female, adult male and microfilariae of the filarial nematode Brugia malayi, one of the etiological agents of human lymphatic filariasis. This proteomic analysis led to the identification of 228 proteins. The list includes 76 proteins with unknown function as well as also proteins with potential immunoregulatory properties, such as protease inhibitors, cytokine homologues and carbohydrate-binding proteins. Larval and adult ESP differed in composition. Only 32 proteins were shared between all three stages/genders. Consistent with this observation, different gene ontology profiles were associated with the different ESP. CONCLUSIONS/SIGNIFICANCE: A comparative analysis of the proteins released in vitro by different forms of a parasitic nematode dwelling in the same host is presented. The catalog of secreted proteins reflects different stage- and gender-specific related processes and different strategies of immune evasion, providing valuable insights on the contribution of each form of the parasite for establishing the host-parasite interaction.

  14. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  15. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    International Nuclear Information System (INIS)

    Sun, Gang; Li, Min; Jiang, Xiang-sen; Li, Li; Peng, Zhao-hui; Mu, Nan-nan

    2012-01-01

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality

  16. Principles of doppler tomography

    International Nuclear Information System (INIS)

    Juhlin, P.

    1992-08-01

    This paper shows how the radon transform can be used to determine vector fields. A scheme to determine the velocity field of a moving fluid by measurements with a continuous doppler signal is suggested. When the flow is confined to a bounded domain, as is the case in most applications, it can be uniquely decomposed into one gradiental and one rotational part. The former vanishes if the fluid is incompressible and source-free, and the latter can be completely reconstructed by the methods proposed in this paper if the domain is simply connected. Special attention is paid to laminar flow in a long cylindrical vessel with circular cross-section. Under such conditions the flow profile becomes parabolic, which makes the vessel recognizable as a typical 'N-shaped' pattern in an image describing the rotation of the velocity field. The vessel yields the same doppler tomographic pattern, no matter how it is sectioned. The ideas presented should be applicable also when studying the flow in blood vessels, even if the flow profile in these is not quite parabolic. The discrepancies only make the 'N-shape' somewhat distorted

  17. Analysis of Doppler effect measurement in FCA cores using JENDL-3.2 library

    International Nuclear Information System (INIS)

    Okajima, Shigeaki

    1996-01-01

    For the evaluation of the calculation accuracy of the 238 U Doppler effect using JENDL-3.2 library, the previously measured Doppler reactivity worths in the FCA were systematically analyzed. In the analysis the Doppler reactivity worth was calculated by a first order perturbation theory. The calculated results were compared with those using JENDL-3.1 library. The JENDL-3.2 calculation in MOX fuel mock-up cores agrees well with the experimental values within the experimental error. In U-235/Pu fuel cores, the JENDL-3.2 calculation gives 12-15% larger Doppler reactivity worths than the JENDL-3.1 calculation. (author)

  18. Development of Rayleigh Doppler lidar for measuring middle atmosphere winds

    Science.gov (United States)

    Raghunath, K.; Patra, A. K.; Narayana Rao, D.

    Interpretation of most of the middle and upper atmospheric dynamical and chemical data relies on the climatological description of the wind field Rayleigh Doppler lidar is one instrument which monitors wind profiles continuously though continuity is limited to clear meteorological conditions in the middle atmosphere A Doppler wind lidar operating in incoherent mode gives excellent wind and temperature information at these altitudes with necessary spectral sensitivity It observes atmospheric winds by measuring the spectral shift of the scattered light due to the motions of atmospheric molecules with background winds and temperature by spectral broadening The presentation is about the design and development of Incoherent Doppler lidar to obtain wind information in the height regions of 30-65 km The paper analyses and describes various types of techniques that can be adopted viz Edge technique and Fringe Imaging technique The paper brings out the scientific objectives configuration simulations error sources and technical challenges involved in the development of Rayleigh Doppler lidar The presentation also gives a novel technique for calibrating the lidar

  19. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  20. Determination of intestinal viability by Doppler ultrasonography in venous infarction.

    Science.gov (United States)

    Cooperman, M; Martin, E W; Carey, L C

    1980-01-01

    The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability. PMID:7352777

  1. Effectiveness of Pulse Oximetry Versus Doppler for Tourniquet Monitoring.

    Science.gov (United States)

    Wall, Piper L; Buising, Charisse M; Grulke, Lisa; Troester, Alexander; Bianchina, Nicholas; White, Shannon; Freymark, Rosemarie; Hassan, Ali; Hopkins, James W; Renner, Catherine Hackett; Sahr, Sheryl M

    Pulse oximeters are common and include arterial pulse detection as part of their methodology. The authors investigated the possible usefulness of pulse oximeters for monitoring extremity tourniquet arterial occlusion. Tactical Ratcheting Medical Tourniquets were tightened to the least Doppler-determined occluding pressure at mid-thigh or mid-arm locations on one limb at a time on all four limbs of 15 volunteers. A randomized block design was used to determine the placement locations of three pulse oximeter sensors on the relevant digits. The times and pressures of pulsatile signal absences and returns were recorded for 200 seconds, with the tourniquet being tightened only when the Doppler ultrasound and all three pulse oximeters had pulsatile signals present (pulsatile waveform traces for the pulse oximeters). From the first Doppler signal absence to tourniquet release, toe-located pulse oximeters missed Doppler signal presence 41% to 50% of the times (discrete 1-second intervals) and missed 39% to 49% of the pressure points (discrete 1mmHg intervals); fingerlocated pulse oximeters had miss rates of 11% to 15% of the times and 13% to 19% of the pressure points. On toes, the pulse oximeter ranges of sensitivity and specificity for Doppler pulse detection were 71% to 90% and 44% to 51%, and on fingers, the respective ranges were 65% to 77% and 78% to 83%. Use of a pulse oximeter to monitor limb tourniquet effectiveness will result in some instances of an undetected weak arterial pulse being present. If a pulse oximeter waveform is obtained from a location distal to a tourniquet, the tourniquet should be tightened. If a pulsatile waveform is not detected, vigilance should be maintained. 2017.

  2. The Doppler paradigm and the APEX-EPOS-ORANGE quandary

    International Nuclear Information System (INIS)

    Griffin, J.J.

    1995-01-01

    The experimental detection of the sharp lines of the (e + e - ) Puzzle is viewed as a struggle against Doppler broadening. Gedanken experiments which are realistic in zeroth order of detail are analyzed to show that the ORANGE and EPOS/I geometries select narrower slices of a Doppler broadened line than spherically inclusive (APEX and EPOS/II -like) apparati. Roughly speaking, the latter require event-by-event Doppler reconstruction simply to regain an even footing with the former. This suggests that APEX' or EPOS/II's coincident pair distributions must be statistically superior to those of EPOS/I or ORANGE in order to support a comparable inference about sharp structure. Under such circumstances, independent alternative data is invaluable. Therefore, a corroboration of Sakai's 330.1 keV ( + or e - bombardments of U and Th targets could prove crucial

  3. Genitourinary MR: Kidneys and adrenal glands

    International Nuclear Information System (INIS)

    Krestin, G.P.

    1999-01-01

    Due to its high tissue contrast and multiplanar imaging capabilites, MRI provides a detailed display of renal and adrenal anatomy. Recent technical developments overcoming the problem of respiration induced motion artifacts and the use of paramagnetic contrast agents have further improved the performance of MRI which has now evolved as an alternative or complementary imaging modality to ultrasound, excretory urography and computed tomography. Dynamic contrast-enhanced studies will usually allow to detect even small enhancing solid areas within the cyst wall. Use of a fast (turbo) spoiled gradient echo sequence allows for assessment of contrast enhancement dynamics in renal and adrenal masses. For tumor staging, the multiplanar imaging capabilities of MRI are advantageous. Perinephric extent is best detected using opposed-phase GRE images resulting in an artifical accentuation of renal contours. Extension into venous structures is best diagnosed by using a GRE sequence allowing for distinction between flowing blood and tumor thrombus. Noninvasive differentiation of adrenal lesions can be performed with an unprecedented accuracy using chemical-shift imaging. (orig.)

  4. Doppler reactivity uncertainties and their effect upon a hypothetical LOF accident

    International Nuclear Information System (INIS)

    Malloy, D.J.

    1976-01-01

    The statistical uncertainties and the major methodological errors which contribute to the Doppler feedback uncertainty were reviewed and investigated. Improved estimates for the magnitudes of each type of uncertainty were established. The generally applied reactivity feedback methodology has been extended by explicitly treating the coupling effect which exists between the various feedback components. The improved methodology was specifically applied to the coupling of Doppler and sodium void reactivities. In addition, the description of the temperature dependence of the Doppler feedback has been improved by the use of a two-constant formula on a global and regional basis. Feedback and coupling coefficients are presented as a first comparison of the improved and the currently applied methods. Further, the energy release which results from hypothetical disassembly accidents was simulated with a special response surface in the parametric safety evaluation code PARSEC. The impact of the improved feedback methodology and of Doppler coefficient uncertainties was illustrated by the usual parametric relationship between available work-energy and the Doppler coefficient. The work-energy was calculated with the VENUS-II disassembly code and was represented as a response surface in PARSEC. Additionally, the probability distribution for available work-energy, which results from the statistical uncertainty of the Doppler coefficient, was calculated for the current and the improved feedback methodology. The improved feedback description yielded about a 16 percent higher average value for the work-energy. A substantially larger increase is found on the high-yield end of the spectrum: the probability for work-energy above 500 MJ was increased by about a factor of ten

  5. Applications of Doppler-free saturation spectroscopy for edge physics studies (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Martin, E. H., E-mail: martineh@ornl.gov; Caughman, J. B. O.; Isler, R. C.; Bell, G. L. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Zafar, A. [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2016-11-15

    Doppler-free saturation spectroscopy provides a very powerful method to obtain detailed information about the electronic structure of the atom through measurement of the spectral line profile. This is achieved through a significant decrease in the Doppler broadening and essentially an elimination of the instrument broadening inherent to passive spectroscopic techniques. In this paper we present the technique and associated physics of Doppler-free saturation spectroscopy in addition to how one selects the appropriate transition. Simulations of H{sub δ} spectra are presented to illustrate the increased sensitivity to both electric field and electron density measurements.

  6. The role of Doppler ultrasonography in the evaluation of the renal function

    International Nuclear Information System (INIS)

    Krasteva, R.; Kiperova, B.; Andreev, E.; Kostadinova, I.; Petrov, T.; Hadjidekov, V.; Simeonova, A.

    2008-01-01

    The purpose of the study was to evaluate Doppler ultrasonography in the detection of the renal function. Sixty six patients with unilateral kidney changes were enrolled in this prospective study. 16 had hypoplastic kidney, 24 had hypofunctioned kidney and 26 had afunctioned kidney. 15 healthy potential donors were controls. A dynamic renal scintigraphy was performed with 74-111 MBq 99mTc-MAG3. The Color, Pulsed and Power Doppler were performed. The Vp and δVp derived from the spectrum of the segmental arteries were measured during Pulsed Doppler examination. There are not any difference between kidneys of health and hypoplastic kidneys on color and Power Doppler. The hypofunctioning kidneys had reduced blood flow and afunctioning kidneys had markedly reduced blood flow. The Vp of donors (48.8±7.6) and Vp of hypoplastic kidneys (49.9±4.8) were significantly higher compared to Vp of hypofunctioning kidneys (31.6±10.0) and to Vp of afunctioning kidneys (26.6±9.1), (p 14.5 cm/s in 93%, and from hypofunctioning kidney by delta Vp>10.5 cm/s in 87%. The Doppler ultrasonography is very useful in the evaluation of renal function. The changes of the Doppler parameters accurately marked the loss of function which can not be detected by elevation of the creatinine level. (authors)

  7. Doppler derived gradient of ST Jude Mechanical Prosthesis, early postoperative assessment

    International Nuclear Information System (INIS)

    Shaikh, A.H.; Hanif, B.; Adil, A.; Hashimi, S.; Qazi, H.A.; Mujtaba, I.

    2010-01-01

    Objective: To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. Methods: Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute, between March 2006 to December 2008 were reviewed. Doppler derived mean gradients were assessed predischarge and recorded. Results: There were 98 (51.5%) males and 92 (48.5%) females in the study cohort. The mean age was 40 +- 14 years. Of the total, 101 (53%) had mitral, 46 (24.2%) had aortic and 43 (22.6%) patients had dual valve replacement. Doppler derived mean gradient was assessed across 144 mitral and 89 aortic St Jude mechanical prosthesis. Doppler derived mean gradient for St Jude mitral prosthesis was 3.5 mm Hg and for St Jude aortic prosthesis was 10.2 mm Hg. Conclusions: The study determines baseline gradients across mitral and aortic St Jude mechanical prosthesis in our population. These can be used as reference gradients to assess St Jude prosthetic valve function in patients who did not have early postoperative doppler assessment. (author)

  8. Toll-Like Receptor-Mediated Free Radical Generation in Clonorchis sinensis Excretory-Secretory Product-Treated Cholangiocarcinoma Cells.

    Science.gov (United States)

    Bahk, Young Yil; Pak, Jhang Ho

    2016-10-01

    Clonorchiasis, caused by direct contact with Clonorchis sinensis worms and their excretory-secretory products (ESPs), is associated with chronic inflammation, malignant changes in bile ducts, and even cholangiocarcinogenesis. Our previous report revealed that intracellular free radicals enzymatically generated by C. sinensis ESPs cause NF-κB-mediated inflammation in human cholangiocarcinoma cells (HuCCT1). Therefore, the present study was conducted to examine the role of upstream Toll-like receptors (TLRs) on the initial host innate immune responses to infection. We found that treatment of HuCCT1 cells with native ESPs induced changes in TLR mRNA levels in a time-dependent manner, concomitant with the generation of free radicals. ESP-mediated free radical generation was markedly attenuated by preincubation of the cells with TLR1-4-neutralizing antibodies, indicating that at least TLR1 through 4 participate in stimulation of the host innate immune responses. These findings indicate that free radicals triggered by ESPs are critically involved in TLR signal transduction. Continuous signaling by this pathway may function in initiating C. sinensis infection-associated inflammation cascades, a detrimental event leading to progression to more severe hepatobiliary diseases.

  9. Three types of gall-bladder motility at men with chronic cholecystitis and pyelonephritis and accompanying their parameters of kidney excretory function as well as metabolism

    Directory of Open Access Journals (Sweden)

    Oksana M Ivanyts’ka

    2018-04-01

    Full Text Available Background. Previously it has been shown that balneotherapy in the spa Truskavets’ (Ukraїna in men with chronic cholecystitis combined with pyelonephritis causes changes in gall-bladder motility. This is combined with changes in diurese and urinary excretion of metabolites.Individual analysis revealed not only quantitative but also qualitative differences in the postprandial motility of the gall-bladder. The purpose of this study is to identify the parameters of kidney excretory function as well as metabolism under which three types of the gall-bladdermotility skills differ significantly from each other. Materialandmethods. The object of observationwere the same ones 22men aged24-70 years old,who cameto the spaTruskavets’ for the treatment of chronic cholecystitiscombined withpyelonephritis inremission. On thetone and motility of gall-bladder judged byits fasting and postprandial volume (echocamera “Radmir”. In the daily  determined content of oxalate and nitrogen metabolites: creatinine, urea and uric acid, electrolytes: phosphates, chloride, calcium, magnesium, potassium and sodium. Nitrogenous metabolites in plasma of venous blood were determined also. The survey was conducted twice, before and after balneotherapy. Results. The method of cluster analysis has formed three homogeneous cholekinetics groups, namely:normokinesia as well as hypertonic-hyperkinetic and hyperkinetic-hypertonic dyskinesia.The method of discriminatory analysis revealed 13 parameters of daily urine and three parameters of blood, as well as body weight and height, electrokinetic index and Kerdoe’s index, in the totality of which three types of cholekinetics are clearly delineated.Conclusion. The type of postprandial cholekinetics is naturally associated with a number of parameters of the excretory renal function and metabolism.

  10. Analysis of placenta vascularization in patients with uterine altered artery Doppler flow velocity exams.

    Science.gov (United States)

    Gilio, Daniel Bruno; Miranda Corrêa, Rosana Rosa; Souza de Oliveira Guimarães, Camila; Peres, Luiz Cesar; Marques Salge, Ana Karina; Cavellani, Camila Lourencini; de Paula Antunes Teixeira, Vicente; Costa da Cunha Castro, Eumenia

    2009-08-01

    One of the frequent questions in obstetric practice is to determine placental vascular changes that may account for abnormal Doppler flow velocity alterations in maternal uterine vessels from women and fetuses without pregnancy pathology. A retrospective morphometric study was realized using 27 placentas from patients submitted for Doppler flow velocity exam during pregnancy. The placentas were morphologically examined using hematoxylin-eosin staining. Measurements of villi were made with the use of a video camera coupled to a common light microscope and a computer with automatic image analyzing software. Of the 27 placentas, 13 (48%) were of patients showing unaltered Doppler and 14 (52%) showing altered Doppler. The number of stem villi vessels was significantly larger in the placentas of patients with Doppler exam alterations (P = 0.003). This group also presented greater stem villi vessel thickness, although without significant difference. The number of intermediary and terminal villi vessels was greater in the placentas of patients with altered Doppler exams (P < 0.001), and a greater terminal villi area was observed in these cases (P < 0.001). The morphological proof that uterine artery Doppler flow velocity exam alterations are associated with placental vascular alterations demonstrates the importance of this exam during prenatal care, even in the absence of maternal-fetal alterations.

  11. Modeling and processing of laser Doppler reactive hyperaemia signals

    Science.gov (United States)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  12. Explanation of the Inverse Doppler Effect Observed in Nonlinear Transmission Lines

    International Nuclear Information System (INIS)

    Kozyrev, Alexander B.; Weide, Daniel W. van der

    2005-01-01

    The theory of the inverse Doppler effect recently observed in magnetic nonlinear transmission lines is developed. We explain the crucial role of the backward spatial harmonic in the occurrence of an inverse Doppler effect and draw analogies of the magnetic nonlinear transmission line to the backward wave oscillator

  13. Research on Fast-Doppler-Broadening of neutron cross sections

    International Nuclear Information System (INIS)

    Li, S.; Wang, K.; Yu, G.

    2012-01-01

    A Fast-Doppler-Broadening method is developed in this work to broaden Continuous Energy neutron cross-sections for Monte Carlo calculations. Gauss integration algorithm and parallel computing are implemented in this method, which is unprecedented in the history of cross section processing. Compared to the traditional code (NJOY, SIGMA1, etc.), the new Fast-Doppler-Broadening method shows a remarkable speedup with keeping accuracy. The purpose of using Gauss integration is to avoid complex derivation of traditional broadening formula and heavy load of computing complementary error function that slows down the Doppler broadening process. The OpenMP environment is utilized in parallel computing which can take full advantage of modern multi-processor computers. Combination of the two can reduce processing time of main actinides (such as 238 U, 235 U) to an order of magnitude of 1∼2 seconds. This new method is fast enough to be applied to Online Doppler broadening. It can be combined or coupled with Monte Carlo transport code to solve temperature dependent problems and neutronics-thermal hydraulics coupled scheme which is a big challenge for the conventional NJOY-MCNP system. Examples are shown to determine the efficiency and relative errors compared with the NJOY results. A Godiva Benchmark is also used in order to test the ACE libraries produced by the new method. (authors)

  14. Macroscopic effects in electromagnetically-induced transparency in a Doppler-broadened system

    International Nuclear Information System (INIS)

    Pei Li-Ya; Qu Yi-Zhi; Niu Jin-Yan; Wang Ru-Quan; Wu Ling-An; Fu Pan-Ming; Zuo Zhan-Chun

    2015-01-01

    We study the electromagnetically-induced transparency (EIT) in a Doppler-broadened cascaded three-level system. We decompose the susceptibility responsible for the EIT resonance into a linear and a nonlinear part, and the EIT resonance reflects mainly the characteristics of the nonlinear susceptibility. It is found that the macroscopic polarization interference effect plays a crucial role in determining the EIT resonance spectrum. To obtain a Doppler-free spectrum there must be polarization interference between atoms of different velocities. A dressed-state model, which analyzes the velocities at which the atoms are in resonance with the dressed states through Doppler frequency shifting, is employed to explain the results. (paper)

  15. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    Science.gov (United States)

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Testing the relativistic Doppler boost hypothesis for supermassive black hole binary candidates

    Science.gov (United States)

    Charisi, Maria; Haiman, Zoltán; Schiminovich, David; D'Orazio, Daniel J.

    2018-06-01

    Supermassive black hole binaries (SMBHBs) should be common in galactic nuclei as a result of frequent galaxy mergers. Recently, a large sample of sub-parsec SMBHB candidates was identified as bright periodically variable quasars in optical surveys. If the observed periodicity corresponds to the redshifted binary orbital period, the inferred orbital velocities are relativistic (v/c ≈ 0.1). The optical and ultraviolet (UV) luminosities are expected to arise from gas bound to the individual BHs, and would be modulated by the relativistic Doppler effect. The optical and UV light curves should vary in tandem with relative amplitudes which depend on the respective spectral slopes. We constructed a control sample of 42 quasars with aperiodic variability, to test whether this Doppler colour signature can be distinguished from intrinsic chromatic variability. We found that the Doppler signature can arise by chance in ˜20 per cent (˜37 per cent) of quasars in the nUV (fUV) band. These probabilities reflect the limited quality of the control sample and represent upper limits on how frequently quasars mimic the Doppler brightness+colour variations. We performed separate tests on the periodic quasar candidates, and found that for the majority, the Doppler boost hypothesis requires an unusually steep UV spectrum or an unexpectedly large BH mass and orbital velocity. We conclude that at most approximately one-third of these periodic candidates can harbor Doppler-modulated SMBHBs.

  17. Aortic isthmus Doppler velocimetry: role in assessment of preterm fetal growth restriction.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-02-01

    Intrauterine fetal growth restriction (IUGR) is an important pregnancy complication associated with significant adverse clinical outcome, stillbirth, perinatal morbidity and cerebral palsy. To date, no uniformly accepted management protocol of Doppler surveillance that reduces mortality and cognitive morbidity has emerged. Aortic isthmus (AoI) evaluation has been proposed as a potential monitoring tool for IUGR fetuses. In this review, the current knowledge of the relationship between AoI Doppler velocimetry and preterm fetal growth restriction is reviewed. Relevant technical aspects and reproducibility data are reviewed as we discuss AoI Doppler and its place within the existing repertoire of Doppler assessments in placental insufficiency. The AoI is a link between the right and left ventricles which perfuse the lower and upper body, respectively. The clinical use of AoI waveforms for monitoring fetal deterioration in IUGR has been limited, but preliminary work suggests that abnormal AoI impedance indices are an intermediate step between placental insufficiency-hypoxemia and cardiac decompensation. Further prospective studies correlating AoI indices with arterial and venous Doppler indices and perinatal outcome are required before encorporating this index into clinical practice.

  18. Doppler-ultrasonographic finding of air in the portal vein: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon [College of Medicine, Hallym University, Seoul (Korea, Republic of)

    1994-03-15

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography.

  19. Doppler-ultrasonographic finding of air in the portal vein: a case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon

    1994-01-01

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography

  20. Ultrasonographic investigation of the Achilles tendon in elite badminton players using color Doppler.

    Science.gov (United States)

    Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren

    2006-12-01

    The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced

  1. Effect of Doppler flow meter position on discharge measurement in surcharged manholes.

    Science.gov (United States)

    Yang, Haoming; Zhu, David Z; Liu, Yanchen

    2018-02-01

    Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.

  2. Correlation between Doppler flow patterns in growth-restricted fetuses and neonatal circulation

    NARCIS (Netherlands)

    Tanis, J. C.; Boelen, M. R.; Schmitz, D. M.; Casarella, L.; van der Laan, M. E.; Bos, A. F.; Bilardo, C. M.

    Objectives To investigate whether prenatal Doppler parameters in growth-restricted fetuses are correlated with neonatal circulatory changes. Methods In 43 cases of suspected fetal growth restriction (FGR), serial Doppler measurements of umbilical artery (UA) and middle cerebral artery (MCA)

  3. Role of Doppler US and MRI in diagnosis of placenta accreta ...

    African Journals Online (AJOL)

    The aim of this work is to evaluate the role of Doppler US and MRI in the diagnosis of placenta accreta. Patients and methods: During period between 2012 to 2013, 120 pregnant patients with previous cesarean section were investigated by ultrasound and Doppler and then in suspected cases MRI was obtained (10 cases).

  4. Kan Doppler-ultralyd erstatte strain gauge til måling af systolisk ankelblodtryk?

    DEFF Research Database (Denmark)

    Sørensen, T L; Perner, A; Hansen, L

    1992-01-01

    Traditionally, strain gauge technique is used in Denmark to measure ankle blood pressure, a method requiring both time and well-trained personnel. In a study involving 90 limbs in 45 patients, this method was compared with ultrasonic technique using a portable 5 MHz Doppler. The reproducibility...... of Doppler ankle pressure measurement was similar to that found in strain gauge based studies. Two consecutive measurements may differ by 20 mmHg or in terms of ankle-brachial index by 0.15 before this is considered significant. No systematic variation was found between the two methods. Increasing...... difficulties were encountered with the Doppler technique at pressures below 50 mmHg. It is concluded that Doppler is a good alternative to strain gauge for measurement of ankle blood pressure....

  5. Transcranial Doppler Ultrasound in Peninsular Arab Patients With Sickle Cell Disease.

    Science.gov (United States)

    Adekile, Adekunle; Hassan, Meaad; Asbeutah, Akram; Al-Hinai, Mohamed; Trad, Omar; Farhan, Nayef

    2018-05-06

    Transcranial Doppler ultrasound is used to identify patients with sickle cell disease (SCD) at risk for stroke. We performed transcranial Doppler studies in patients from 4 countries in the Arabian Peninsula (Kuwait, Oman, Iraq, and United Arab Emirates) to document the prevalence of abnormal transcranial Doppler findings. The patients were recruited from outpatient clinics and studied in a steady state. Transcranial Doppler examinations were performed with standard equipment by experienced operators. The time-averaged maximum mean velocity (TAMMV) was documented in the arteries of the circle of Willis. The hemoglobin (Hb) genotype was confirmed, and the fetal Hb level and complete blood counts were determined. There were 415 patients in the study, aged 2 to 18 years (mean ± SD, 8.6 ± 3.5 years). None of the patients had an abnormal TAMMV (ie, > 200 cm/s), whereas only 13 (3.1%), all from Iraq, had conditional values (170-200 cm/s) in the right middle cerebral artery and 7 (1.7%) in the left middle cerebral artery. There were no consistent TAMMV differences among male and female patients or in patients with different Hb genotypes (sickle cell anemia, sickle cell β 0- thalassemia, and sickle D). The use of hydroxyurea was associated with a lower TAMMV, whereas a blood transfusion history had no influence. Total hemoglobin, reticulocyte count, serum bilirubin, and fetal Hb values showed varying degrees of association with the TAMMV in the different vessels. This study has demonstrated the rarity of abnormal transcranial Doppler findings among Peninsular Arab patients with SCD. The guidelines for transcranial Doppler screening in this population need further studies and recommendations. © 2018 by the American Institute of Ultrasound in Medicine.

  6. Doppler echocardiographic predictors of mortality in female rats after myocardial infarction.

    Science.gov (United States)

    Santos, Alexandra Alberta; Helber, Izzo; Flumignan, Ronald L G; Antonio, Ednei L; Carvalho, Antonio C; Paola, Angelo A; Tucci, Paulo J; Moises, Valdir A

    2009-03-01

    Doppler echocardiogram is useful for the evaluation of anatomical and functional changes in late myocardial infarction (MI) in rats. However, no studies have evaluated the prognostic value of echocardiographic parameters 1 week after MI. Doppler echocardiogram was performed in 84 female Wistar rats 1 week after MI to determine infarction size, left chambers dimensions, fractional area change (FAC) of the left ventricle (LV), mitral inflow and tissue Doppler, myocardial performance index (MPI), and signs of pulmonary hypertension. The 365-day follow-up showed 53.6% mortality rate. Nonsurvivors showed larger (P or=0.60 (RR 3.49, 95% CI, 1.80-6.76), LV systolic area >or=0.26 cm(2) (RR 4.38, 95% CI, 1.88-10.21), E/E' ratio >or=20.3 (RR 2.12, 95% CI, 1.15-4.34), and E/A ratio associated with FAC (RR 2.99, 95% CI, 1.44-6.18). Some diastolic and systolic Doppler echocardiographic parameters in rats may be able to predict late mortality risk after MI.

  7. Hyperdiagnostic of renal tumor by intravenous urography in patient with adult polycystic disease

    International Nuclear Information System (INIS)

    Djerassi, R.; Lubomirova, M.; Mutafova, I.; Bogov, B.; Gavrikova, V.; Garvanska, G.

    2005-01-01

    Autosomal dominant polycystic kidney disease (ADPKD) is one of the often seen (from 1:400 to 1:1000) inherited renal diseases with serious prognosis. The exact diagnosis, earlier treatment of the urinary tract infections and hypertension were the steps for prevention of the renal disease progression. The abdominal ultrasound is method used for screening. The frequency of the renal tumors in general population was not higher compared to those in patients with ADPKD. We described and discussed the results obtained by different imaging techniques in 23 years old female with family history for ADPKD. She was admitted to the 'Alexandrovska' University Hospital Nephrology Clinic because of the recurrence of the urinary tract infection. The diagnosis of renal tumor was suspected by renal intravenous pyelography (IVP). All the others imaging techniques - Triplex sonography-B-mode, Color, Pulse, Power Doppler, Tissue Doppler as well as contrast computer tomography showed the polycystic kidney disease, without focal changes, with several small cysts based in the medulla near distal calyces. This was probably the reason for the false-positive image made by IVP. The diagnostic values of the different imaging techniques in making the exact diagnosis in patients with polycystic kidney disease were comment, as well as a peculiar ultrasound image of the polycystic kidney in young patients, aged less then 30 years. To make the correct diagnosis of ADPKD the combination of all known imaging techniques was needed. The small kidney tumors were better visualized by tissue-harmonic ultrasound

  8. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  9. Doppler effect measurement in FCA assemblies X-3 and XI-1

    International Nuclear Information System (INIS)

    Okajima, Shigeaki; Mukaiyama, Takehiko

    1984-05-01

    Doppler reactivity worths were measured in FCA assemblies X-3 (mock-up core for JOYO Mark II) and XI-1 (mock-up core for large scale LMFBR) for U-238 and stractural materials of core (iron, stainless steel and nickel). The sample oscillation technique was used to measure the Doppler effect when a sample is heated up to 800 0 C from room temperature. The analysis was made using the 70 group JFS-3-J2 data set, and compared with the measured results. For U-238 samples, the calculation underestimates Doppler effects by 10%, on the other hand for other samples, the agreement between calculated values and measured values is quite good. (author)

  10. Vesico-ureteral reflux: diagnosis and staging with voiding color doppler US Preliminary experience

    International Nuclear Information System (INIS)

    Farina, Renato; Arena, Carmela; Pennisi, Francesco; Di Benedetto, Vincenzo; Politi, Guido; Di Benedetto, Aurelio

    2000-01-01

    Introduction: The aim of this study is to assess the accuracy of a new US examination: 'voiding color Doppler US ' in the early diagnosis and staging of vesico-ureteral reflux (VUR). The contrast agent US was SH U 508A (Levovist, Schering, Berlin), which produces a chromatic accentuation of the signals picked up by the color Doppler US. Eighteen patients (10 females, eight males) were recruited for the study. In two patients a second examination was performed for follow-up after a VUR conservative therapy. All patients were taken under examination for the evaluation of possible VUR. In all patients the voiding color Doppler US was followed by voiding cystourethrography (VCUG) and the data obtained were compared. Materials and methods: A total of 18 patients aged between 3 months and 10 years, were recruited for the study. The results of the examination were the following: urinary tract infections, follow-up of VUR after conservative or surgical therapy, miscellaneous indications. Voiding color Doppler US was performed, followed by a VCUG. The voiding color Doppler US consists in the trans-catheter introduction of a contrast agent SHU 508 A (Levovist, Schering, Ag. Berlin) into the bladder and a subsequent test with the color Doppler US to show or exclude the presence of reflux into the ureters and/or into the pyelo-caliceal cavity of the kidneys. After the introduction of the contrast agent US the ultrasound scanning of the bladder, the ureters and the pyelo-caliceal cavity was performed to examine the reflux degree. The ultrasonographic investigations were perfomed with AU 590 asyncronus US (Esaote Biomedica, Genova) with a 3.5 MHz convex probe. Results: After the trans-catheter introduction of the contrast agent US, vesico-ureteral reflux occured in 13 patients (77.2%). The reflux degree was also measured by means of ultrasound and was later confirmed by VCUG. The mean times of each examination were as follows: initial US, 10 min; catheterization, 8 min; voiding

  11. Application of Energy Window Concept in Doppler Broadening of {sup 238}U Cross Section

    Energy Technology Data Exchange (ETDEWEB)

    Khassnov, Azamat; Choi, Soo Young; Lee, Deok Jung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    Currently, the NJOY code is used for construction and Doppler broadening of microscopic cross sections. There exist several methods or formalisms to produce microscopic cross sections and there are also different methods of Doppler broadening. In this paper, Multi-Level Breit-Wigner (MLBW) formalism and the Psi method are used for generation and Doppler broadening of the resonance cross section. Accuracy of the energy window concept applied MLBW (EW MLBW) Doppler broadened cross section was compared with that of the cross section generated by conventional MLBW (Con MLBW) formalism for {sup 2}38U isotope using MATLAB. The conventional method requires Doppler broadening of all resonances, including resonances far from the target energy point, which do not change much with respect to the temperature change. The energy window concept makes Doppler broadening possible with a smaller number of resonances neighboring to the energy point we are interested in, and just adds up 0 K temperature cross sections of other resonances. Multi-level Breit-Wigner formalism and the Doppler broadening method were used to construct microscopic cross sections of {sup 238}U at different temperatures. The energy window concept was applied only for the 1st resonance energy region (4.5∼11.2 eV). The energy window concept demonstrates high competitiveness because the relative differences were less than 0.0016% for all types of cross sections. The advantage of the energy window concept is that the number of resonances broadened for every energy point is significantly reduced, which allows a reduction of computation time by almost 45 % of Doppler broadening time of the cross section generation at temperatures higher than 0 K.

  12. On the Fly Doppler Broadening Using Multipole Representation

    International Nuclear Information System (INIS)

    Khassenov, Azamat; Choi, Sooyoung; Lee, Deokjung

    2015-01-01

    On the Fly Doppler broadening is the technique to avoid pre-generation of the microscopic cross section, in other words, reduce the amount of storage. Currently, there are different types of formalisms used by NJOY code to generate reaction cross section and accomplish its Doppler broadening. Single-Level Breit-Wigner (SLBW) formalism is limited to well-separated resonances, in other words, it does not consider interference between energy levels. Multi-Level Breit- Wigner formalism (MLBW) was tested as the candidate for the cross section generation in the Monte Carlo code, which is under development in UNIST. According to the results, MLBW method requires huge amount of computational time to produce cross section at certain energy point. Reich-Moore (RM) technique can generate only 0K cross section, which means that it cannot produce broaden cross section directly from resonance parameters. The first step was to convert resonance parameters given in nuclear data file into multipoles. MPR shows very high potential to be used as the formalism in the on-the-fly Doppler broadening module of MCS. One of the main reasons is that comparison of the time cost shown in Table IV supports application of multipole representation

  13. Doppler ultrasound study of penis in men with systemic sclerosis: a correlation with Doppler indices of renal and digital arteries.

    Science.gov (United States)

    Rosato, E; Barbano, B; Gigante, A; Cianci, R; Molinaro, I; Quarta, S; Digiulio, M A; Messineo, D; Pisarri, S; Salsano, F

    2013-01-01

    Erectile dysfunction (ED) prevalence in male systemic sclerosis (SSc) is high and its pathogenesis is unclear. The aim of the study is to assess correlation between Doppler ultrasound indices of penis and kidneys or digital arteries in male systemic sclerosis. Fourteen men with systemic sclerosis were enrolled in this study. Erectile function was investigated by the International Index of Erectile Function-5. Peak systolic velocity, end diastolic velocity, resistive index, pulsative index, and systolic/diastolic ratio were measured on the cavernous arteries at the peno-scrotal junction in the flaccid state, on the interlobar artery of both kidneys and all ten proper palmar digital arteries. Ten (71 percent) patients have an International Index of Erectile Function-5 less than 21. Reduction of penis peak systolic velocity was observed in all SSc subjects. Doppler indices of cavernous arteries correlate with the International Index of Erectile Function-5. The renal and digital arteries resistive index demonstrated a good correlation (p less than 0.0001) with International Index of Erectile Function-5. A positive correlation exists between penis and kidney arteries Doppler indices: end diastolic velocity (p less than 0.05, r=0.54), resistive index (p less than 0.0001, r=0.90), systolic/diastolic ratio (p less than 0.01, r=0.69). A positive correlation was observed between penis and digital arteries Doppler indices: peak systolic velocity (p less than 0.01, r=0.68), end diastolic velocity (p less than 0.01, r=0.75), resistive index (p less than 0.001, r=0.79), systolic/diastolic ratio (p less than 0.05, r=0.59). A correlation exists between arterial impairment of penis and renal or digital arteries.

  14. An ocean current inversion accuracy analysis based on a Doppler spectrum model

    Institute of Scientific and Technical Information of China (English)

    BAO Qingliu; ZHANG Youguang; LIN Mingsen; GONG Peng

    2017-01-01

    Microwave remote sensing is one of the most useful methods for observing the ocean parameters.The Doppler frequency or interferometric phase of the radar echoes can be used for an ocean surface current speed retrieval,which is widely used in spaceborne and airborne radars.While the effect of the ocean currents and waves is interactional.It is impossible to retrieve the ocean surface current speed from Doppler frequency shift directly.In order to study the relationship between the ocean surface current speed and the Doppler frequency shift,a numerical ocean surface Doppler spectrum model is established and validated with a reference.The input parameters of ocean Doppler spectrum include an ocean wave elevation model,a directional distribution function,and wind speed and direction.The suitable ocean wave elevation spectrum and the directional distribution function are selected by comparing the ocean Doppler spectrum in C band with an empirical geophysical model function (CDOP).What is more,the error sensitivities of ocean surface current speed to the wind speed and direction are analyzed.All these simulations are in Ku band.The simulation results show that the ocean surface current speed error is sensitive to the wind speed and direction errors.With VV polarization,the ocean surface current speed error is about 0.15 m/s when the wind speed error is 2 m/s,and the ocean surface current speed error is smaller than 0.3 m/s when the wind direction error is within 20° in the cross wind direction.

  15. Fresh look at the doppler changes in pregnancies with placental-based complications

    Directory of Open Access Journals (Sweden)

    S Dikshit

    2011-01-01

    Full Text Available Placental-based complications of pregnancy can be classified as acute and chronic. An example of acute placental complication is abruptio placenta. The chronic placental complications include pregnancy induced hypertension (PIH and idiopathic Intrauterine growth restriction (IUGR. The fetus is at risk for perinatal complications in both acute and chronic conditions. Here we take a look at the natural history of the Doppler parameters in chronic conditions. The techniques used for assessing the fetal well-being include, clinical methods, biophysical tests, conventional ultrasonography, and fetal Doppler studies. Arterial Doppler studies are used to assess the well-being of the fetus and to determine the timing of delivery. However, arterial Dopplers predict only the subset of fetuses at risk of having perinatal complications. Venous Dopplers have been used to improve upon the prognostication. However, by the time the commonly used venous Doppler signs, that is, ′A′ wave reversal in ductus venosus (DV is present, the fetus is likely to be already compromised. The fetus tries to adapt to the environment of deprivation by making a series of changes in the umbilical artery circulation, cerebral circulation, and hepatic circulation. As a result of these adaptations, the fetus overcomes the state of chronic hypoxia. This article takes a look at these changes and also the effect of these adaptations. It is suggested that serial comparisons of the venous flow characteristics of the DV and inferior vena cava (IVC can provide an early indication of the impending decompensation and can be used to predict the time the delivery.

  16. Proteomic analysis of the excretory/secretory products and antigenic proteins of Echinococcus granulosus adult worms from infected dogs.

    Science.gov (United States)

    Wang, Ying; Xiao, Di; Shen, Yujuan; Han, Xiuming; Zhao, Fei; Li, Xiaohong; Wu, Weiping; Zhou, Hejun; Zhang, Jianzhong; Cao, Jianping

    2015-05-21

    Cystic echinococcosis, which is caused by Echinococcus granulosus, is one of the most widespread zoonotic helminth diseases that affects humans and livestock. Dogs, which harbor adult worms in their small intestines, are a pivotal source of E. granulosus infection in humans and domestic animals. Therefore, novel molecular approaches for the prevention and diagnosis of this parasite infection in dogs need to be developed. In this study, we performed proteomic analysis to identify excretory/secretory products (ES) and antigenic proteins of E. granulosus adult worms using two-dimensional electrophoresis, tandem matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF/TOF), and Western blotting of sera from infected dogs. This study identified 33 ES product spots corresponding to 9 different proteins and 21 antigenic protein spots corresponding to 13 different proteins. Six antigenic proteins were identified for the first time. The present study extended the existing proteomic data of E. granulosus and provides further information regarding host-parasite interactions and survival mechanisms. The results of this study contribute to vaccination and immunodiagnoses for E. granulosus infections.

  17. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  18. Contrast-enhanced power Doppler US of hepatocellular carcinomas: Quantitative analysis

    International Nuclear Information System (INIS)

    Kim, Ah Young; Choi, Byung Ihn; Kim, Tae Kyoung; Lee, Kyoung Ho; Han, Joon Koo

    1999-01-01

    To determine peak time and duration of contrast enhancement of nodular hepatocellular carcinoma (HCC) on contrast-enhancement power Doppler ultrasound (US) with Levovist by quantitative analysis. Twenty eight patients with nodular HCC were prospectively evaluated with power Doppler US by one examiner. Serial images were obtained before and after injection of 300 mg/mL US contrast agent (SH U 508 A, Levovist, Schering) with the injection rate of 0.2 mL/sec. Power Doppler signals on obtained digital images were quantified using 'Ultrasound Imaging Tool Version 1.0' (Seoul, Korea). The grade, peak time and duration of contrast enhancement of the tumors were analyzed. For nodular HCCs, mean peak enhancement time was 60 seconds after injection of Levovist (mean enhanced area 41.6 ± 28.6 %). These tumoral enhancement decreased from 90 seconds and returned to near baseline state at 5 minutes after injection of Levovist. Maximum enhanced areas (%) were variable at a range of 8-98.5% and mean maximum enhanced area was 46.4 ± 28.6%. On contrast-enhanced power Doppler US with Levovist, nodular HCCs showed peak contrast enhancement (41.6± 28.6) at 60 seconds after injection of contrast agent. This tumoral enhancement nearly disappeared at 5 minutes after injection of contrast agent.

  19. Method and system of doppler correction for mobile communications systems

    Science.gov (United States)

    Georghiades, Costas N. (Inventor); Spasojevic, Predrag (Inventor)

    1999-01-01

    Doppler correction system and method comprising receiving a Doppler effected signal comprising a preamble signal (32). A delayed preamble signal (48) may be generated based on the preamble signal (32). The preamble signal (32) may be multiplied by the delayed preamble signal (48) to generate an in-phase preamble signal (60). The in-phase preamble signal (60) may be filtered to generate a substantially constant in-phase preamble signal (62). A plurality of samples of the substantially constant in-phase preamble signal (62) may be accumulated. A phase-shifted signal (76) may also be generated based on the preamble signal (32). The phase-shifted signal (76) may be multiplied by the delayed preamble signal (48) to generate an out-of-phase preamble signal (80). The out-of-phase preamble signal (80) may be filtered to generate a substantially constant out-of-phase preamble signal (82). A plurality of samples of the substantially constant out-of-phase signal (82) may be accumulated. A sum of the in-phase preamble samples and a sum of the out-of-phase preamble samples may be normalized relative to each other to generate an in-phase Doppler estimator (92) and an out-of-phase Doppler estimator (94).

  20. Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths

    DEFF Research Database (Denmark)

    Ammitzboll-Danielsen, Mads; Janta, Iustina; Torp-Pedersen, Søren

    2016-01-01

    interpretation of Doppler signals when diagnosing tenosynovitis. Method Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger...... participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84). Conclusion Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers...

  1. Laser sub-Doppler cooling of atoms in an arbitrarily directed magnetic field

    International Nuclear Information System (INIS)

    Chang, Soo; Kwon, Taeg Yong; Lee, Ho Seong; Minogin, V.G.

    2002-01-01

    We analyze the influence of an arbitrarily directed uniform magnetic field on the laser sub-Doppler cooling of atoms. The analysis is done for a (3+5)-level atom excited by a σ + -σ - laser field configuration. Our analysis shows that the effects of the magnetic field depend strongly on the direction of the magnetic field. In an arbitrarily directed magnetic field the laser cooling configuration produces both the main resonance existing already at zero magnetic field and additional sub-Doppler resonances caused by two-photon and higher-order multiphoton processes. These sub-Doppler resonances are, however, well separated on the velocity scale if the Zeeman shift exceeds the widths of the resonances. This allows one to use the main sub-Doppler resonance for an effective laser cooling of atoms even in the presence of the magnetic field. The effective temperature of the atomic ensemble at the velocity of the main resonance is found to be almost the same as in the absence of the magnetic field. The defined structure of the multiphoton resonances may be of importance for the sub-Doppler laser cooling of atoms, atomic extraction from magneto-optical traps, and applications related to the control of atomic motion

  2. Optimized variational analysis scheme of single Doppler radar wind data

    Science.gov (United States)

    Sasaki, Yoshi K.; Allen, Steve; Mizuno, Koki; Whitehead, Victor; Wilk, Kenneth E.

    1989-01-01

    A computer scheme for extracting singularities has been developed and applied to single Doppler radar wind data. The scheme is planned for use in real-time wind and singularity analysis and forecasting. The method, known as Doppler Operational Variational Extraction of Singularities is outlined, focusing on the principle of local symmetry. Results are presented from the application of the scheme to a storm-generated gust front in Oklahoma on May 28, 1987.

  3. Method and apparatus for Doppler frequency modulation of radiation

    Science.gov (United States)

    Margolis, J. S.; Mccleese, D. J.; Shumate, M. S.; Seaman, C. H. (Inventor)

    1980-01-01

    A method and apparatus are described for frequency modulating radiation, such as from a laser, for optoacoustic detectors, interferometers, heterodyne spectrometers, and similar devices. Two oppositely reciprocating cats-eye retroreflectors are used to Doppler modulate the radiation. By reciprocally moving both retroreflectors, the center of mass is maintained constant to permit smooth operation at many Hertz. By slightly offsetting the axis of one retroreflector relative to the other, multiple passes of a light beam may be achieved for greater Doppler shifts with the same reciprocating motion of the retroreflectors.

  4. Analysis of multiple scattering effects in optical Doppler tomography

    DEFF Research Database (Denmark)

    Yura, H.T.; Thrane, L.; Andersen, Peter E.

    2005-01-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where...... multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed...

  5. Calculation results and experimental testing of doppler feedback coefficients

    International Nuclear Information System (INIS)

    Yang Shunhai

    1989-01-01

    The Doppler feedback coefficients are calculated by the interpolation and group collapsing method from multigroup self-shielding factors and infinite dilution cross sections rather than effective resonance integrals by using resonance data base. Since many updated sets of multigroup data are in existence to be selected, the calculation process can be simplified. The heterogeneous effects are taken into account by equivalence relation. The computer code of Doppler feedback coefficients is created on computer CYBER-825 and PDP-11. The results calculated are in good agreement with the experiments

  6. The use of contrast-enhanced color doppler ultrasound in the differentiation of retinal detachment from vitreous membrane

    International Nuclear Information System (INIS)

    Han, Sang Suk; Chang, Seung Kook; Yoon, Jung Hee; Lee, Young Joon

    2001-01-01

    To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD

  7. Laser Doppler thermometry in flat flames

    NARCIS (Netherlands)

    Maaren, van A.; Goey, de L.P.H.

    1994-01-01

    Laser Doppler Velocimetry measurements are performed in flat flames, stabilized on a newly developed flat-flame burner. It is shown that the velocity component perpendicular to the main flow direction, induced by expansion in the reaction zone and buoyancy in the burnt gas, is significant. A method

  8. Renal duplex Doppler ultrasound findings in diabetics

    International Nuclear Information System (INIS)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon

    1993-01-01

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  9. Renal duplex Doppler ultrasound findings in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1993-12-15

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  10. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  11. Accuracy of doppler ultrasound in diagnosis of endometrial carcinoma

    International Nuclear Information System (INIS)

    Batool, S.; Raza, S.; Manzur, S.

    2013-01-01

    Objective: To determine the accuracy of Doppler ultrasound in the diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding while taking histopathological findings as the gold standard. Methods: The cross-sectional study was done at the Department of Radiology, Bahawal Victoria Hospital, Bahawalpur, from April 1 to September 30, 2009, and comprised 128 patients above 50 years of age having history of post-menopausal bleeding and who were referred to the department. Name, age and hospital registration number were recorded on a proforma. Doppler ultrasound was performed and endometrial thickness and uterine artery resistive index were recorded on transabdominal ultrasonography. Patients with endometrial thickness of more than 5mm and uterine artery resistive index of less than 0.7 were considered to be having endometrial carcinoma. Histopathology findings were also recorded using the hospital registration number of the patient. The findings of Doppler ultrasound scan were validated with the findings of histopathology. Results: Of the 128 patients, 48 (37.5%) were between the ages of 51 and 55 years; 46 (35.93%) were in the 56-60 age group; and 34 (26.57%) were over 65 years. On the basis of Doppler ultrasound findings, 106 (82.8%) patients were diagnosed as having endometrial carcinoma, while 22 (17.19%) were declared negative. Ultrasonography results were compared with histopathology findings. The percentages of true positive, true negative, false positive and false negative were calculated. There were 103 (80.47%) true positive; 12 (9.37%) false positive; 10 (7.81%) true negative; and 3 (2.35%) false negative. Specificity, sensitivity, positive predictive value and negative predictive value were found to be 97.16%, 76%, 89.56% and 76.92% respectively. Conclusion: The use of Doppler ultrasonography in non-invasive diagnosis of endometrial carcinoma in patients presenting with post-menopausal bleeding was quite useful with good

  12. Operator auditory perception and spectral quantification of umbilical artery Doppler ultrasound signals.

    Directory of Open Access Journals (Sweden)

    Ann Thuring

    Full Text Available OBJECTIVE: An experienced sonographer can by listening to the Doppler audio signals perceive various timbres that distinguish different types of umbilical artery flow despite an unchanged pulsatility index (PI. Our aim was to develop an objective measure of the Doppler audio signals recorded from fetoplacental circulation in a sheep model. METHODS: Various degrees of pathological flow velocity waveforms in the umbilical artery, similar to those in human complicated pregnancies, were induced by microsphere embolization of the placental bed (embolization model, 7 lamb fetuses, 370 Doppler recordings or by fetal hemodilution (anemia model, 4 lamb fetuses, 184 recordings. A subjective 11-step operator auditory scale (OAS was related to conventional Doppler parameters, PI and time average mean velocity (TAM, and to sound frequency analysis of Doppler signals (sound frequency with the maximum energy content [MAXpeak] and frequency band at maximum level minus 15 dB [MAXpeak-15 dB] over several heart cycles. RESULTS: WE FOUND A NEGATIVE CORRELATION BETWEEN THE OAS AND PI: median Rho -0.73 (range -0.35- -0.94 and -0.68 (range -0.57- -0.78 in the two lamb models, respectively. There was a positive correlation between OAS and TAM in both models: median Rho 0.80 (range 0.58-0.95 and 0.90 (range 0.78-0.95, respectively. A strong correlation was found between TAM and the results of sound spectrum analysis; in the embolization model the median r was 0.91 (range 0.88-0.97 for MAXpeak and 0.91 (range 0.82-0.98 for MAXpeak-15 dB. In the anemia model, the corresponding values were 0.92 (range 0.78-0.96 and 0.96 (range 0.89-0.98, respectively. CONCLUSION: Audio-spectrum analysis reflects the subjective perception of Doppler sound signals in the umbilical artery and has a strong correlation to TAM-velocity. This information might be of importance for clinical management of complicated pregnancies as an addition to conventional Doppler parameters.

  13. Normal Doppler velocimetry of renal vasculature in Persian cats.

    Science.gov (United States)

    Carvalho, Cibele F; Chammas, Maria C

    2011-06-01

    Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n=50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17±13.46 cm/s and 0.38±0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15±0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17±9.40 cm/s and 0.54±0.07. The RA had a mean ESA of 1.12±1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828±0.296. The IA showed PSV and RI values of 32.16±9.33 cm/s and 0.52±0.06, respectively. The mean ESA of all IAs was 0.73±0.61 m/s(2). The calculated upper limit of the reference value was 2.0m

  14. Low-frequency high-definition power Doppler in visualizing and defining fetal pulmonary venous connections.

    Science.gov (United States)

    Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong

    2014-07-01

    The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.

  15. The value of multi-slice spiral CT in the preoperative assessment of living renal donor

    International Nuclear Information System (INIS)

    Li Qinghai; Yan Fuhua; Xu Pengju; Zhou Meiling; Zhu Tongyu; Xu Ming; Wang Guomin

    2008-01-01

    Objective: The purpose of this study is to assess the value of multi-slice spiral CT (MSCT) in the preoperative evaluation of living renal donor as a all in one modality. Methods: Thirty-six potential living renal donors underwent the examination using a GE light VCT scanner. Informed consent was obtained from all participants. The plain scan, early arterial phase, late arterial phase and excretory phase scans are performed in the former 25 donors (injection rate 5 rolls, total volume 100 mi, tube tension 120 kV). While in the later 11 donors (2 ml/s 40 ml +4 ml/s 60 ml), the scanning protocol included the plain scan ( 100 kV), vascular phase and excretory phase scans (100 kV). The excretory phase data were used in the reconstruction of CT urography in both groups. All images were reviewed by one radiologist and one urologist, and the findings of MSCT were compared with intraoperative findings for 33 donors, to investigate the utilities of MSCT in assessing renal vascularity, urinary tract and lesions of renal parenchyma. When discrepancies are found between the two reviewers, consensus was obtained via discussion. Au data was statiscally processed with SPSS for Windows. Results: MSCT angiography is in accordance with intraoperative findings in demonstrating the anatomy of renal arteries and renal vein trunk, accesary arteries, early branching of renal artery. The findings from CTA are highly in accordance with the intraoperative findings, which facilitate intraoperative ligation and reduce relevant complications. CTU demonstrates the anatomy of urinary, tract in good agreement with the intraoperative findings. The image quality of 3D vascularity and CTU between the two groups, scored 4.4 ± 1.2 vs 4.2 ± 1.3 and 4.6 ± 0.8 vs 4.4 ± 0.9 respectively, no statistical between-groups difference was found (Z=-0.89, -0.47, P>0.05). Conclusion: MSCT multiphase scanning combined with CTA and CTU play a important role in the evaluation of living renal donor, which

  16. Glare Spot Phase Doppler Anemometry

    Science.gov (United States)

    Hespel, Camille; Ren, Kuanfang; Gréhan, Gérard; Onofri, Fabrice

    2007-06-01

    The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index would be also interesting since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemometry which uses two large beams. In this case, the images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes in the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences between two signals, the distance and the intensity ratio of reflected and refracted parts can be obtained and they provide rich information about the particle diameter and its refractive index, as well as its velocity. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  17. Genome analysis of Excretory/Secretory proteins in Taenia solium reveals their Abundance of Antigenic Regions (AAR).

    Science.gov (United States)

    Gomez, Sandra; Adalid-Peralta, Laura; Palafox-Fonseca, Hector; Cantu-Robles, Vito Adrian; Soberón, Xavier; Sciutto, Edda; Fragoso, Gladis; Bobes, Raúl J; Laclette, Juan P; Yauner, Luis del Pozo; Ochoa-Leyva, Adrián

    2015-05-19

    Excretory/Secretory (ES) proteins play an important role in the host-parasite interactions. Experimental identification of ES proteins is time-consuming and expensive. Alternative bioinformatics approaches are cost-effective and can be used to prioritize the experimental analysis of therapeutic targets for parasitic diseases. Here we predicted and functionally annotated the ES proteins in T. solium genome using an integration of bioinformatics tools. Additionally, we developed a novel measurement to evaluate the potential antigenicity of T. solium secretome using sequence length and number of antigenic regions of ES proteins. This measurement was formalized as the Abundance of Antigenic Regions (AAR) value. AAR value for secretome showed a similar value to that obtained for a set of experimentally determined antigenic proteins and was different to the calculated value for the non-ES proteins of T. solium genome. Furthermore, we calculated the AAR values for known helminth secretomes and they were similar to that obtained for T. solium. The results reveal the utility of AAR value as a novel genomic measurement to evaluate the potential antigenicity of secretomes. This comprehensive analysis of T. solium secretome provides functional information for future experimental studies, including the identification of novel ES proteins of therapeutic, diagnosis and immunological interest.

  18. Proteinases in excretory-secretory products of Toxocara canis second-stage larvae: zymography and modeling insights.

    Science.gov (United States)

    González-Páez, Gonzalo Ernesto; Alba-Hurtado, Fernando; García-Tovar, Carlos Gerardo; Argüello-García, Raúl

    2014-01-01

    Components released in excretory-secretory products of Toxocara canis larvae (TES) include phosphatidylethanolamine-binding proteins (TES26), mucins (TES120, MUC2-5), and C-type lectins (TES32, TES70) and their biochemical, immunological, and diagnostic properties have been extensively studied albeit proteinase activities towards physiological substrates are almost unknown. Proteolytic activities in TES samples were first analyzed by gel electrophoresis with gelatin as substrate. Major activities of ~400, 120, and 32 kDa in TES were relatively similar over a broad pH range (5.5-9.0) and all these were of the serine-type as leupeptin abolished gelatinolysis. Further, the ~400 kDa component degraded all physiological substrates tested (laminin, fibronectin, albumin, and goat IgG) and the 120 kDa component degraded albumin and goat IgG while proteinases of lower MW (45, 32, and 26 kDa) only degraded laminin and fibronectin, preferentially at alkaline pH (9.0). By protein modeling approaches using the known sequences of TES components, only TES26 and MUC4 displayed folding patterns significantly related to reference serine proteinases. These data suggest that most of serine proteinase activities secreted in vitro by infective larvae of T. canis have intriguing nature but otherwise help the parasite to affect multiple components of somatic organs and bodily fluids within the infected host.

  19. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  20. Excretory products of the cestode, Schistocephalus solidus, modulate in vitro responses of leukocytes from its specific host, the three-spined stickleback (Gasterosteus aculeatus).

    Science.gov (United States)

    Scharsack, Jörn Peter; Gossens, Anabel; Franke, Frederik; Kurtz, Joachim

    2013-12-01

    Helminth parasites have evolved remarkable strategies to manipulate the immune system of their hosts. During infections of three-spined stickleback (Gasterosteus aculeatus) with the cestode Schistocephalus solidus prominent immunological changes occur, presumably due to manipulative activity of the parasite. We hypothesise that excretory/secretory products of the parasite are involved in the manipulation of the stickleback's immune system and that this may depend on the individual parasite and its origin. We therefore produced S. solidus conditioned cell culture media (SSCM) with parasites from different origins (Norway, Spain and Germany) and exposed head kidney leukocytes (HKL) from un-infected sticklebacks in cell cultures to SSCM. After in vitro culture, HKL were subjected to differential cell counts (granulocytes/lymphocytes) by means of flow cytometry. Leukocyte sub-populations were analysed for cell viability and changes in cell morphology. The respiratory burst activity was measured with a luminescence assay. Exposure of HKL to SSCM induced an up-regulation of respiratory burst activity after already 1 h, which was still elevated at 24 h, but which was in some cases significantly down-regulated after 96 h. Respiratory burst was positively correlated with the number of live granulocytes in the culture, suggesting that the respiratory burst activity was changed by SSCM effects on granulocyte viability. After 1 h and 24 h of HKL culture, no lymphocyte responses to SSCM were detectable, but after 96 h lymphocyte viability was significantly decreased with SSCM from Spanish S. solidus. In these cultures, residual lymphocytes increased in size, suggesting that cell death and activation might have occurred in parallel. The highest respiratory burst activity was induced by SSCM from Spanish parasites, in particular when they were grown in sympatric sticklebacks. The in vitro HKL responses to SSCM depended on the individual parasite and its population of origin