WorldWideScience

Sample records for excimer lasers

  1. excimer laser

    Indian Academy of Sciences (India)

    2014-01-07

    Jan 7, 2014 ... Excimer laser; krypton chloride; UV pre-ionization; gas circulation. PACS No 42.55.Lt. 1. ... active discharge volume is by spark UV radiation created adjacent to both sides of the. Figure 4. Output ... HV electrode, all along its length and spatially modulated to ensure uniform irradiation of the gas volume.

  2. Excimer Laser Technology

    CERN Document Server

    Basting, Dirk

    2005-01-01

    This comprehensive survey on Excimer Lasers investigates the current range of the technology, applications and devices of this commonly used laser source, as well as the future of new technologies, such as F2 laser technology. Additional chapters on optics, devices and laser systems complete this compact handbook. A must read for laser technology students, process application researchers, engineers or anyone interested in excimer laser technology. An effective and understandable introduction to the current and future status of excimer laser technology.

  3. Excimer Laser Etching

    Energy Technology Data Exchange (ETDEWEB)

    Boatner, Lynn A [ORNL; Longmire, Hu Foster [ORNL; Rouleau, Christopher M [ORNL; Gray, Allison S [ORNL

    2008-04-01

    Excimer laser radiation at a wavelength of = 248 nm represents a new etching method for the preparation of metallographic specimens. The method is shown to be particularly effective for enhancing the contrast between different phases in a multiphase metallographic specimen.

  4. Excimer lasers for refractive surgery

    Science.gov (United States)

    Vartapetov, Serge K.

    2003-10-01

    Over the last decade excimer lasers have been broadly used for technological and medical processes. One of the most widespread applications of excimer laser is the clinical use for refractive surgery. Refractive surgery with excimer lasers is the prevalent method for the eye acuity correction. Operation at 193 nanometers, the excimer laser is able to precisely sculpt the corneal surface to correct refractive errors. Both the increase in the accuracy of sculpturing and the predictability of procedures are the key elements of the excimer laser designed for refractive surgery. The novel excimer laser for refractive surgery is offered for small aberration treatment. The excimer laser with both a full aperture Gaussian beam and fly spot system is described. The comparison of different systems of laser correction is reviewed.

  5. Excimer laser drilling of polymers

    Science.gov (United States)

    Chen, Yihong; Zheng, HongYu; Wong, Terence K. S.; Tam, Siu Chung

    1997-08-01

    Laser micro-drilling technology plays a more and more important role in industry, especially in the fabrication of multi-layer electronic packages. In such applications, non- metals are often used as insulators, in which via holes are formed to provide vertical interconnections for densely packed 3D wiring networks. Mechanical punch tools have been the primary means to form holes in ceramic sheets and in polymer boards since the 1970's. As the cost of fabricating punch heads increases drastically and the demand for quick turn around part build becomes more routine, flexible via forming technologies, such as laser drilling, have become more prevalent. In laser drilling, CO2, Nd:YAG, and excimer lasers are often used. Their drilling capabilities, drilling mechanisms, and hole qualities are different because of the different laser beam characteristics such as wavelength and beam energy distribution. In this paper, the mechanisms of laser drilling are briefly reviewed. The results of the experiments on excimer laser drilling of two types of polymer: polyimide and polyethylene terephthalate, are reported. It is found that the etch rate increases with increase of fluence, an the wall angle of drilled holes is dependent on the fluence. The material removal by a laser pulse is highly controllable. There exists an optimal fluence range to obtain clean and smooth edges of quality holes for a given material at a given laser wavelength.

  6. Corneal wound healing after excimer laser keratectomy.

    Science.gov (United States)

    Kaji, Yuichi; Yamashita, Hidetoshi; Oshika, Tetsuro

    2003-03-01

    Excimer laser keratectomy is widely used to correct refractive errors. Several complications of excimer laser keratectomy are reported including corneal infection, regression, corneal haze formation, glare and halo. Most of the complications are closely related to the corneal stromal wound healing process. In order to perform the excimer laser keratectomy with minimum complications, we should understand the mechanism of the corneal stroma wound healing process. In addition, such knowledge will help us to regulate the corneal stromal wound healing process in the future. In the present article, we discuss the molecular mechanism of the corneal stromal wound healing process after excimer laser keratectomy and its regulation by anti-inflammatory agents.

  7. (308 nm) excimer laser

    Indian Academy of Sciences (India)

    The UV lasers with high quantum energy photons directly break the atomic and molecular bonds within material. The photons in this spectral range are also capable of inducing photo- chemical reactions. Most solid materials have high absorption in the UV. The short pulses result in reducing interaction time between laser ...

  8. Excimer laser etching of polyimide

    Science.gov (United States)

    Brannon, J. H.; Lankard, J. R.; Baise, A. I.; Burns, F.; Kaufman, J.

    1985-09-01

    It is reported that thin films of polyimide are efficiently etched in air at pulsed excimer laser wavelengths of 248, 308, and 351 nm. Etch rate versus incident fluence data are found to obey a Beer-Lambert etching relation. Sharp laser fluence thresholds for significant etching are found to correlate with the wavelength-dependent absorption coefficient. The absorbed energy density required to initiate significant etching is found, within experimental error, to be independent of the wavelengths examined. It is felt that this information demonstrates the predominantly thermal nature of the laser etching mechanism. Additionally, infrared spectroscopy and coupled gas chromatography/mass spectroscopy were used to identify several gases evolved during pulsed laser etching of polyimide in both air and vacuum.

  9. Applications of the Excimer Laser: A Review.

    Science.gov (United States)

    Beggs, Sarah; Short, Jack; Rengifo-Pardo, Monica; Ehrlich, Alison

    2015-11-01

    The 308-nm excimer laser has been approved by the Food and Drug Administration for the treatment of psoriasis and vitiligo. Its ability to treat localized areas has led to many studies determining its potential in the treatment of focal diseases with inflammation or hypopigmentation. To review the different applications of the 308-nm excimer laser for treating dermatologic conditions. An extensive literature review was conducted by searching PubMed, MEDLINE, and ClinicalKey to find articles pertaining to dermatologic conditions treated with the 308-nm excimer laser. Articles published that contributed to new applications of the excimer laser were included, as well as initial studies utilizing the excimer laser. The outcomes and results were compiled for different dermatologic conditions treated with the excimer laser. The 308-nm excimer laser has a wide range of uses for focal inflammatory and hypopigmented conditions. Treatment is generally well tolerated, with few adverse reactions. Larger studies and studies evaluating the long-term effects of the 308-nm excimer laser are needed.

  10. Mitomicina C e "Excimer laser" Mitomycin C and Excimer Laser

    Directory of Open Access Journals (Sweden)

    Anelise Dutra Wallau

    2005-12-01

    Full Text Available A mitomicina C é um antimetabólito que atua em nível celular bloqueando a replicação de DNA e RNA e inibindo a síntese protéica. Utilizada em diversas áreas da oftalmologia, recentemente vem sendo empregada como moduladora da resposta cicatricial corneana em cirurgias ópticas/refrativas por "excimer laser". A aplicação única de mitomicina C associada à cirurgia fotoablativa de superfície corneana tem se mostrado opção segura e eficiente para fins terapêuticos em olhos com opacidade corneana pré-existente e/ou profiláticos em olhos com alto risco de desenvolvimento de opacificação corneana pós-operatória. O uso da droga em cirurgia fotoablativa deve ser cauteloso até que seguimento de longo prazo avalie sua inocuidade tardia. O presente texto faz revisão dos principais estudos sobre modulação da resposta cicatricial corneana com uso de mitomicina C em cirurgias ópticas/refrativas de superfície.Mitomycin C is an antimetabolite agent that blocks DNA and RNA replication and protein synthesis. It has been used in several ophthalmologic areas, and recently as a modulator of corneal wound healing in excimer laser surgeries. A single application of mitomycin C during surface corneal photoablative surgery seems a safe and efficient therapeutic option for eyes with corneal opacity and/or as prophylaxis in eyes with high risk for corneal opacity development. The use of this drug in photoablative surgery should be cautious until long-term safety results have been reported. The present text presents a review about corneal wound healing with the use of mitomycin C.

  11. 308-nm excimer laser in endodontics

    Science.gov (United States)

    Liesenhoff, Tim

    1992-06-01

    Root canal preparation was performed on 20 extracted human teeth. After opening the coronal pulp, the root canals were prepared by 308 nm excimer laser only. All root canals were investigated under SEM after separation in the axial direction. By sagittal separation of the mandibles of freshly slaughtered cows, it was possible to get access to the tissues and irradiate under optical control. Under irradiation of excimer laser light, tissue starts to fluoresce. It was possible to demonstrate that each tissue (dentin, enamel, bone, pulpal, and connective tissue) has a characteristic spectral pattern. The SEM analyses showed that it is well possible to prepare root canals safely. All organic soft tissue has been removed by excimer laser irradiation. There was no case of via falsa. The simultaneous spectroscopic identification of the irradiated tissue provides a safe protection from overinstrumentation. First clinical trials on 20 patients suffering of chronical apical parodontitis have been carried out successfully.

  12. Investigation of excimer laser ablation of iron

    Science.gov (United States)

    Jordan, R.; Lunney, J. G.

    1998-05-01

    The excimer ablation of iron at 248 nm has been investigated by measuring the ablation depth and average ion energy as a function of laser fluence. Measurements have also been made of the laser transmission through the ablated vapour above the target. The absolute spectral intensity of the emission from the ablation plasma has been measured in both the vacuum ultraviolet and the visible. All results were compared with a simple numerical model describing the main physical processes involved in laser ablation of metal targets.

  13. Excimer laser irradiation of metal surfaces

    Science.gov (United States)

    Kinsman, Grant

    In this work a new method of enhancing CO2 laser processing by modifying the radiative properties of a metal surface is studied. In this procedure, an excimer laser (XeCl) or KrF) exposes the metal surface to overlapping pulses of high intensity, 10(exp 8) - 10(exp 9) W cm(exp -2), and short pulse duration, 30 nsec FWHM (Full Width Half Maximum), to promote structural and chemical change. The major processing effect at these intensities is the production of a surface plasma which can lead to the formation of a laser supported detonation wave (LSD wave). This shock wave can interact with the thin molten layer on the metal surface influencing to a varying degree surface oxidation and roughness features. The possibility of the expulsion, oxidation and redeposition of molten droplets, leading to the formation of micron thick oxide layers, is related to bulk metal properties and the incident laser intensity. A correlation is found between the expulsion of molten droplets and a Reynolds number, showing the interaction is turbulent. The permanent effects of these interactions on metal surfaces are observed through scanning electron microscopy (SEM), transient calorimetric measurements and Fourier transform infrared (FTIR) spectroscopy. Observed surface textures are related to the scanning procedures used to irradiate the metal surface. Fundamental radiative properties of a metal surface, the total hemispherical emissivity, the near-normal spectral absorptivity, and others are examined in this study as they are affected by excimer laser radiation. It is determined that for heavily exposed Al surface, alpha' (10.6 microns) can be increased to values close to unity. Data relating to material removal rates and chemical surface modification for excimer laser radiation is also discussed. The resultant reduction in the near-normal reflectivity solves the fundamental problem of coupling laser radiation into highly reflective and conductive metals such as copper and aluminum. The

  14. Subpicosecond, high-brightness excimer laser systems

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, A.J.; Gosnell, T.R.; Roberts, J.P.; Lester, C.S.; Gibson, R.B.; Harper, S.E.; Tallman, C.R.

    1988-01-01

    Subpicosecond, high-brightness excimer laser systems are being used to explore the interaction of intense coherent ultraviolet radiation with matter. Applications of current systems include generation of picosecond x-ray pulses, investigation of possible x-ray laser pumping schemes, studies of multiphoton phenomena in atomic species, and time-resolved photochemistry. These systems, based on the amplification of subpicosecond pulses in small aperture (/approximately/1 cm/sup 2/) XeCl or KrF amplifiers, deliver focal spot intensities of /approximately/10/sup 17/ W/cm/sup 2/. Scaling to higher intensities, however, will require an additional large aperture amplifier which preserves near-diffraction-limited beam quality and subpicosecond pulse duration. We describe here both a small aperture KrF system which routinely provides intensities >10/sup 17/ W/cm/sup 2/ to several experiments, and a large aperture XeCl system designed to deliver /approximately/1 J subpicosecond pulses and yield intensities on target in excess of 10/sup 19/W/cm/sup 2/. We also discuss the effects of two-photon absorption on large-aperture, high-brightness excimer lasers. 4 refs., 2 figs.

  15. Electrodeless excimer laser; Laser a eccimeri senza elettrodi

    Energy Technology Data Exchange (ETDEWEB)

    Lisi, N. [ENEA, Divisione Nuovi Materiali, Centro Ricerche Casaccia, Rome (Italy)

    2001-07-01

    In this paper it is proposed how to build an excimer laser based on an electrodeless discharge (or Dielectric Barrier Discharge). Such laser could operate with a low energy per pulse (<100 mJ) and a high repetition rate (<100 kHz). The most relevant advantage an electrodeless DBD laser is the much longer gas mixture lifetime. This feature could allow the operation of a sealed laser emitting higher average power with respect to commercially available excimer lasers. Such discharge scheme could be advantageous in order to excite the F{sub 2} excimer molecule, whose emission wavelength in the VUV range (157 nm) at high reprate is particularly interesting in the micro-lithography field. [Italian] In questo documento viene proposto come costruire un laser a eccimeri basato su una scarica priva di elettrodi, o Dielectric Barrier Discharge. Tale laser puo' funzionare con una bassa energia per impulso (<100 mJ) ad alta frequenza di ripetizione (<100 kHz). Il vantaggio fondamentale di un laser a DBD e quindi privo di elettrodi e' la vita media della miscela gassosa molto piu' alta che potrebbe permettere alla camera laser di operare sigillata ad una potenza media superiore a quella dei laser a eccimeri attuali. Tale schema di pompaggio potrebbe essere particolarmente vantaggioso per eccitare la molecola eccimero F{sub 2} la cui lunghezza di emissione nel VUV (157 nm) ad elevata frequenza di ripetizione presenta un notevole interesse nel campo della produzione di microcircuiti.

  16. Excimer laser phototherapeutic keratectomy for keratoconus nodules.

    Science.gov (United States)

    Elsahn, Ahmed F; Rapuano, Christopher J; Antunes, Victor A; Abdalla, Yasmine F; Cohen, Elisabeth J

    2009-02-01

    To report the outcomes of contact lens-intolerant patients with keratoconus (KCN) with subepithelial nodules treated with excimer laser phototherapeutic keratectomy (PTK). The charts of all contact lens-intolerant patients with KCN who underwent excimer laser PTK for subepithelial nodules were identified using a computer database and were retrospectively reviewed. Preoperative and postoperative visual acuity and method of correction, surgical treatment, epithelial healing, complications, and KCN nodule recurrence were all analyzed. Fifteen eyes of 15 patients with a minimum follow-up of 3 months were reviewed. Mean follow-up time was 23.1 months (SD +/- 42.5 months, range 3-143 months). In 9 eyes, the epithelial defect healed by postoperative day 3 and all eyes healed by postoperative day 6. There was no infection or corneal melting in any of the eyes. After PTK, 11 patients were refit successfully with rigid gas-permeable contact lenses and 4 wore glasses. Three patients had a recurrence of the KCN nodule at 3, 8, and 23 months postoperatively. One of them had a repeat PTK 23 months after the initial surgery, improving to 20/40 with contact lenses at 55 months postoperatively. Another patient decided to have a penetrating keratoplasty, and the third patient is considering repeat PTK or penetrating keratoplasty. PTK effectively removed KCN nodules without recurrences in most patients and can be a successful modality to improve contact lens tolerance and delay or avoid more invasive surgery.

  17. Excimer Lasers With Capacitively Excited Tubular Discharges

    Science.gov (United States)

    Eichler, Hans J.; Herweg, Helmut; de la Rosa, Jose

    1989-04-01

    The excitation of excimer lasers in tubular discharges results in simple and compact devices needing no preionization. Optical output energies are in the millijoule range. We investigated XeF, KrF and ArF lasers for various operating conditions. The lasers consist of capillary glass tubes with two internal electrodes at the ends and an aluminium-foil wrapped around the tube as capacitive electrode. A maximum output energy of 0.3 mJ has been achieved for the XeF laser. The good quality of the discharge is indicated by the observation of spontaneous mode locking. The detailed study of the discharge for different polarities of the electrodes has shown that efficient operation with a high gas lifetime can be obtained by a purely capacitively excited discharge. A gas lifetime of about 10,000 pulses for 3 litres gas mixture has been observed. Using a two stage Marx generator to generate 100 kV excitation voltage a maximum output energy of 0.7 mJ was obtained for a gas mixture of Kr, F2 and He with an efficiency of 0.17%. The KrF laser operates also without the buffer gas. Laser action in ArF has been achieved with 15 μJ pulse energy and 10 ns duration.

  18. [Glycosaminoglycans in subepithelial opacity after excimer laser keratectomy].

    Science.gov (United States)

    Nakayasu, K; Gotoh, T; Ishikawa, T; Kanai, A

    1996-05-01

    We evaluated histochemically the characteristics of glycosaminoglycans and proteoglycans in the corneal subepithelial opacity after excimer laser keratectomy on rabbit corneas. We also performed the same evaluations on the cornea after mechanical keratectomy. Twenty days after the operations, the area immediately subjacent to the epithelium showed strong staining with toluidine blue, alcian blue, and colloidal iron. However, after treatment with chondroitinase ABC or chondroitinase AC, alcian blue staining in this area decreased dramatically. Antilarge proteoglycan antibody also reacted strongly in this area. Histochemical and immunohistochemical examination of the cornea where mechanical keratectomy was done showed basically similar findings with the cornea of excimer laser keratectomy. These results suggest that large-molecula proteoglycans with chondroitine sulfate side chains become localized in the subepithelial area after two different kinds of keratectomies. We presume from histochemical and immunohistochemical observations that the subepithelial opacity observed after excimer laser keratectomy is not a special reaction to excimer laser but simply a corneal scar formed after stromal resection.

  19. Ignition by excimer laser photolysis of ozone

    Science.gov (United States)

    Lucas, D.; Dunn-Rankin, D.; Hom, K.; Brown, N. J.

    1986-10-01

    We have ignited mixtures of hydrogen, oxygen, and ozone in closed cells with 248 nm radiation from a KrF excimer laser. Ozone, the only significant absorber in this system, absorbs a single photon and produces oxygen atoms which initiate combustion. A discretized, time-dependent Beer's law model is used to demonstrate that the radical concentration immediately after photolysis is a function of laser power, ozone concentration, focal length, and separation between the lens and reaction cell. Spark schileren photographs are used to visualize the ignition events and identify the ignition sites. The effects of equivalence ratio, pressure, and the initial gas temperature on the minimum ozone concentration needed to produce ignition are presented, and only the initial temperature has a significant effect. Modelling studies of the ignition process aid in the interpretation of the experimental results, and show that the ignition we observe is not due solely to thermal effects, but is strongly dependent on the number and type of radicals present initially after photolysis. Ignition using other hydrocarbons as fuels was also demonstrated.

  20. The Excimer Laser: Its Impact on Science and Industry

    Science.gov (United States)

    Basting, Dirk

    2010-03-01

    After the laser was demonstrated in 1960, 15 years were required to develop a practical method for extending laser emission into the UV: the Excimer laser. This historical review will describe the challenges with the new medium and provide an insight into the technological achievements. In the transition from Science to Industry it will be shown how start-ups successfully commercialized laboratory prototypes. The pioneers in this rapidly expanding field will be identified and the influence of government-funded research as well as the role of venture capital will be discussed. In scientific applications, the fields of photochemistry and material research were particularly stimulated by the advent of a reliable UV light source. Numerous industrial applications and worldwide research in novel applications were fueled In the early and mid 80's by progress in excimer laser performance and technology. The discovery of ablative photocomposition of polymer materials by Srinivasan at IBM opened the door to a multitude of important excimer applications. Micromachining with extreme precision with an excimer laser enabled the success of the inkjet printer business. Biological materials such as the human cornea can also be ``machined'' at 193nm, as proposed in 1983 by Trokel and Srinivasan. This provided the foundation of a new medical technology and an industry relying on the excimer laser to perform refractive surgery to correct vision Today, by far the largest use of the excimer laser is in photolithography to manufacture semiconductor chips, an application discovered by Jain at IBM in the early 80's. Moore's law of shrinking the size of the structure to multiply the number of transistors on a chip could not have held true for so long without the deep UV excimer laser as a light source. The presentation will conclude with comments on the most recent applications and latest market trends.

  1. Comparative shock wave analysis during corneal ablation with an excimer laser, picosecond laser, and femtosecond laser

    Science.gov (United States)

    Krueger, Ronald R.; Juhasz, Tibor

    1995-05-01

    With the event of topographic steep central islands following excimer laser surgery and the potential damage to the corneal endothelium, shock waves are playing an increasingly important role in laser refractive surgery. With this in mind, we performed a comparative shock wave analysis in corneal tissue using an excimer laser, picosecond laser, and femtosecond laser. We used a Lambda Physik excimer laser at 308 nm wavelength, a Nd:YLF picosecond laser at 1053 nm wavelength and a synchronously pumped linear cavity femtosecond laser at 630 nm wavelength. The pulse widths of the corresponding lasers were 8 ns, 18 ps, 150 fs, respectively. The energy density of irradiation was 2.5 to 8 times the threshold level being 2 J/cm2 (excimer laser), 86 J/cm2 (picosecond laser) and 10.3 J/cm2 (femtosecond laser). Shock wave dynamics were analyzed using time-resolved photography on a nanosecond time scale using the picosecond laser in corneal tissue, water and air. Shock wave dynamics using the femtosecond laser were studied in water only while the excimer laser induced shock wave during corneal ablation was studied in air only. We found the dynamics of shock waves to be similar in water and corneal tissue indicating that water is a good model to investigate shock wave effects in the cornea. The magnitude of the shock wave velocity and pressure decays over time to that of a sound wave. The distance over which it decays is 3 mm in air with the excimer laser and 600 - 700 micrometers in air with the picosecond laser. In water, the picosecond laser shock wave decays over a distance of 150 micrometers compared to the femtosecond laser shock wave which decays over a distance of 30 micrometers . Overall the excimer laser shock wave propagates 5 times further than that of the picosecond laser and the picosecond laser shock wave propagates 5 times further than that of the femtosecond laser. In this preliminary comparison, the time and distance for shock wave decay appears to be directly

  2. Overview on the high power excimer laser technology

    Science.gov (United States)

    Liu, Jingru

    2013-05-01

    High power excimer laser has essential applications in the fields of high energy density physics, inertial fusion energy and industry owing to its advantages such as short wavelength, high gain, wide bandwidth, energy scalable and repetition operating ability. This overview is aimed at an introduction and evaluation of enormous endeavor of the international high power excimer laser community in the last 30 years. The main technologies of high power excimer laser are reviewed, which include the pumping source technology, angular multiplexing and pulse compressing, beam-smoothing and homogenous irradiation, high efficiency and repetitive operation et al. A high power XeCl laser system developed in NINT of China is described in detail.

  3. New Class of Excimer-Pumped Atomic Lasers (XPALS)

    Science.gov (United States)

    2017-01-27

    AFRL-AFOSR-VA-TR-2017-0019 New Class of Excimer-Pumped Atomic Lasers (XPALS) James Eden UNIVERSITY OF ILLINOIS CHAMPAIGN 506 S WRIGHT ST 364 HENRY...TITLE AND SUBTITLE New Class of Excimer-Pumped Atomic Lasers (XPALS) 5a. CONIKA\\.INUMBER FA9550-13- 1-0006 5b.GRANT NUMBER Sc. f’ftOGRAM ELEMENT...cxcitcd state-excited state reaction rates. We ore pleased to report that the main goal orthis program, the viability of nn atomic laser having a

  4. Excimer laser interaction with dentin of the human tooth

    Science.gov (United States)

    Hammond, Ernest C., Jr.; Gilliam, Ruth L.; Baker, George R.

    1989-01-01

    The use an excimer laser produced many unusual conical structures within the dentin of the inner part of the human tooth. By varying the frequency of the laser one can disperse the energy and cause more bleeding in laser surgery, but not destroy the cells associated with the incision. Therefore, the healing process will virtually be without scarring. Whereas, using the infrared laser the blood loss would be less, but the healing process would tend to be longer because cells are being destroyed due to the cauterization effect of the laser. The question is, are these structures produced as an interaction with the laser or are they an intrinsic part of the structure. The effects of the laser interaction upon dentin was studied, and in using electron microscopy the interaction of the excimer laser upon the tooth dentin and other various biological tissue is more clearly understood.

  5. Topographic steep central islands following excimer laser photorefractive keratectomy

    Science.gov (United States)

    Krueger, Ronald R.; McDonnell, Peter J.

    1994-06-01

    The purpose of this study is to demonstrate that topographic irregularities in the form of central islands of higher refractive power can be seen following excimer laser refractive surgery. We reviewed the computerized corneal topographic maps of 35 patients undergoing excimer laser PRK for compound myopic astigmatism or anisometropia from 8/91 to 8/93 at the USC/Doheny Eye Institute. The topographic maps were generated by the Computed Anatomy Corneal Modeling System, and central islands were defined as topographic areas of steepening of at least 3 diopters and 3 mm in diameter. A grading system was developed based on the presence of central islands during the postoperative period. Visually significant topographic steep central islands may be seen in over 50% of patients at 1 month following excimer laser PRK, and persist at 3 months in up to 24% of patients without nitrogen gas blowing. Loss of best corrected visual acuity or ghosting is associated with island formation, and may prolong visual rehabilitation after excimer laser PRK.

  6. HSP47 expression in cornea after excimer laser photoablation.

    Science.gov (United States)

    Kasagi, Yasuo; Yamashita, Hidetoshi

    2002-01-01

    The expression of heat shock protein 47 (HSP47) was observed histologically to investigate the spatial and chronological effects of excimer laser photoablation. HSP47 expression after radial keratotomy (RK) was also investigated and compared with the effects after excimer laser photoablation. Twenty-eight male rabbits were used. The rabbits were divided with two groups and treated with either excimer laser photoablation or four radial incisions to simulate corneal refractive surgery. The chronological and spatial changes in the expression of HSP47 were observed immunohistochemically. In eyes that underwent excimer laser photoablation, HSP47 was detected in the basal layer of the epithelial cells and in the superficial stromal layer 3 days after surgery. After 5 and 7 days, HSP47 expression extended to the deep layer of the stroma and to the endothelial cells. After 14 days, HSP47 was detected only in the deep layer of the stroma and in the endothelial cells. After 28 days, HSP47 expression was reduced. In eyes that underwent RK, HSP47 was detected in the basal layer of the epithelial cells and in the stroma surrounding the wound 1 day after surgery. After 3 and 7 days, HSP47 expression did not expand further. After 28 days, HSP47 expression diminished. Excimer laser photoablation affects the whole layer of the cornea, and may be caused by the shock wave that occurs as a result of photoablation. In addition, interaction among the keratocytes may propagate the stress-induced response to the whole layer of the cornea. With RK, the wound is smaller and deeper. HSP47 expression occurs earlier, but is limited to the area surrounding the wound.

  7. Corrosion resistance improvement of metals by excimer laser surface treatment

    Science.gov (United States)

    Autric, Michel L.; Perrais, Jacqueline; Barreau, Gerard

    2000-02-01

    KrF excimer laser has been used for physical and chemical transformations of metallic materials and coated metal samples. Aluminum alloys, steels and chromium coated mild steel have been treated under excimer laser radiation in order to improve their mechanical properties and their corrosion and oxidation resistance. The laser surface treatment leads, after surface remelting process, to important changes in the topography, the microstructure, the phases and the chemical composition of the near-surface region resulting in different hardness, wear properties and corrosion/oxidation behavior. We focus this paper on aluminum alloys (2000 and 6000 type) and steels irradiated using a krypton fluoride laser (20 ns, 0.5 - 10 J/cm2, up to 200 Hz) in laboratory air. The analysis were carried out by means of scanning electron microscopy, energy dispersive spectroscopy, coupled and low incidence angle X-ray diffraction, microhardness tester and electrochemical test equipments.

  8. Excimer laser assisted chemical machining of SiC ceramic

    Science.gov (United States)

    Hibi, Yuko; Enomoto, Yuji; Kikuchi, Kaoru; Shikata, Nobuo; Ogiso, Hisato

    1995-02-01

    A highly effective method of machining ceramic has been newly developed using a krypton fluoride (KrF) excimer laser with a 248 nm wavelength. The laser was irradiated on SiC in water to form a soft hydrous oxide layer by photochemical reaction. The softened layer was then cut with a diamond tool to form a mirror surface finish. The optimum conditions were found for both high machining rate and better surface integrity of SiC.

  9. Impacts of excimer laser annealing on Ge epilayer on Si

    Science.gov (United States)

    Huang, Zhiwei; Mao, Yichen; Yi, Xiaohui; Lin, Guangyang; Li, Cheng; Chen, Songyan; Huang, Wei; Wang, Jianyuan

    2017-02-01

    The impacts of excimer laser annealing on the crystallinity of Ge epilayers on Si substrate grown by low- and high-temperature two-step approach in an ultra-high vacuum chemical vapor deposition system were investigated. The samples were treated by excimer laser annealing (ELA) at various laser power densities with the temperature above the melting point of Ge, while below that of Si, resulting in effective reduction of point defects and dislocations in the Ge layer with smooth surface. The full-width at half-maximum (FWHM) of X-ray diffraction patterns of the low-temperature Ge epilayer decreases with the increase in laser power density, indicating the crystalline improvement and negligible effect of Ge-Si intermixing during ELA processes. The short laser pulse time and large cooling rate cause quick melting and recrystallization of Ge epilayer on Si in the non-thermal equilibrium process, rendering tensile strain in Ge epilayer as calculated quantitatively with thermal mismatch between Si and Ge. The FWHM of X-ray diffraction patterns is significantly reduced for the two-step grown samples after treated by a combination of ELA and conventional furnace thermal annealing, indicating that the crystalline of Ge epilayer is improved more effectively with pre- annealing by excimer laser.

  10. Lead extraction experience with high frequency excimer laser.

    Science.gov (United States)

    Tanawuttiwat, Tanyanan; Gallego, Daniel; Carrillo, Roger G

    2014-09-01

    A higher frequency Excimer laser sheath using an 80-Hz pulse repetitive rate was approved by the Food and Drug Administration in April 2012. We reported our initial clinical experience with a high-frequency Excimer laser sheath and compared it with lower-frequency laser sheaths which have been previously used. In this single center, retrospective cohort study, we evaluated patients who underwent lead extraction from December 2008 to May 2013. Those who underwent lead removal without using a laser sheath or with approaches other than subclavian were excluded. Primary endpoints included total laser time, number of pulses, and complications. Data on clinical characteristics, lead type, indications, and outcomes were prospectively collected and analyzed. A total of 427 patients were included in the study (72.6% male; age 67.9 ± 15.23 years). Lower frequency and higher frequency laser sheaths were used in 315 and 112 patients, respectively. A total of 821 leads were removed with 765 leads (93.2%) extracted using the Excimer laser sheath. Lead age was 5.71 ± 4.96 years. Complete extraction was seen in all patients. A higher-frequency laser sheath was associated with a lower laser time and a lower total number of laser pulses even after adjustments for the number of leads, type of leads, and lead age. In the higher frequency group, mortality rate was 0.9% and minor complication rate was 3.6%. When compared with the lower-frequency laser sheath, the higher-frequency laser sheath requires less laser times and more efficient amount of pulses for lead extraction with comparable success rate. Due to the rarity of major and minor complications, no statistical significance was found between the two groups. ©2014 Wiley Periodicals, Inc.

  11. Triggering Excimer Lasers by Photoionization from Corona Discharges

    Science.gov (United States)

    Xiong, Zhongmin; Duffey, Thomas; Brown, Daniel; Kushner, Mark

    2009-10-01

    High repetition rate ArF (192 nm) excimer lasers are used for photolithography sources in microelectronics fabrication. In highly attaching gas mixtures, preionization is critical to obtaining stable, reproducible glow discharges. Photoionization from a separate corona discharge is one technique for preionization which triggers the subsequent electron avalanche between the main electrodes. Photoionization triggering of an ArF excimer laser sustained in multi-atmosphere Ne/Ar/F2/Xe gas mixtures has been investigated using a 2-dimensional plasma hydrodynamics model including radiation transport. Continuity equations for charged and neutral species, and Poisson's equation are solved coincident with the electron temperature with transport coefficients obtained from solutions of Boltzmann's equation. Photoionizing radiation is produced by a surface discharge which propagates along a corona-bar located adjacent to the discharge electrodes. The consequences of pulse power waveform, corona bar location, capacitance and gas mixture on uniformity, symmetry and gain of the avalanche discharge will be discussed.

  12. Subjective results of excimer laser correction of myopia. Review

    Directory of Open Access Journals (Sweden)

    V. N. Trubilin

    2012-01-01

    Full Text Available In review presents data of various authors regarding the subjective results excimer laser correction of myopia by LASIK. It was revealed that a group of patients with a high degree of dissatisfaction amounts to 4.6% of the total in all studies. High subjective results are confirmed by the positive dynamics of the «quality of life» of the patient.

  13. Automatic alignment of double optical paths in excimer laser amplifier

    Science.gov (United States)

    Wang, Dahui; Zhao, Xueqing; Hua, Hengqi; Zhang, Yongsheng; Hu, Yun; Yi, Aiping; Zhao, Jun

    2013-05-01

    A kind of beam automatic alignment method used for double paths amplification in the electron pumped excimer laser system is demonstrated. In this way, the beams from the amplifiers can be transferred along the designated direction and accordingly irradiate on the target with high stabilization and accuracy. However, owing to nonexistence of natural alignment references in excimer laser amplifiers, two cross-hairs structure is used to align the beams. Here, one crosshair put into the input beam is regarded as the near-field reference while the other put into output beam is regarded as the far-field reference. The two cross-hairs are transmitted onto Charge Coupled Devices (CCD) by image-relaying structures separately. The errors between intersection points of two cross-talk images and centroid coordinates of actual beam are recorded automatically and sent to closed loop feedback control mechanism. Negative feedback keeps running until preset accuracy is reached. On the basis of above-mentioned design, the alignment optical path is built and the software is compiled, whereafter the experiment of double paths automatic alignment in electron pumped excimer laser amplifier is carried through. Meanwhile, the related influencing factors and the alignment precision are analyzed. Experimental results indicate that the alignment system can achieve the aiming direction of automatic aligning beams in short time. The analysis shows that the accuracy of alignment system is 0.63μrad and the beam maximum restoration error is 13.75μm. Furthermore, the bigger distance between the two cross-hairs, the higher precision of the system is. Therefore, the automatic alignment system has been used in angular multiplexing excimer Main Oscillation Power Amplification (MOPA) system and can satisfy the requirement of beam alignment precision on the whole.

  14. Penetrating Keratoplasty for Keratoconus – Excimer Versus Femtosecond Laser Trephination

    Science.gov (United States)

    Seitz, Berthold; Langenbucher, Achim; Hager, Tobias; Janunts, Edgar; El-Husseiny, Moatasem; Szentmáry, Nora

    2017-01-01

    Background: In case of keratoconus, rigid gas-permeable contact lenses as the correction method of first choice allow for a good visual acuity for quite some time. In a severe stage of the disease with major cone-shaped protrusion of the cornea, even specially designed keratoconus contact lenses are no more tolerated. In case of existing contraindications for intrastromal ring segments, corneal transplantation typically has a very good prognosis. Methods: In case of advanced keratoconus – especially after corneal hydrops due to rupture of Descemet’s membrane – penetrating keratoplasty (PKP) still is the surgical method of first choice. Noncontact excimer laser trephination seems to be especially beneficial for eyes with iatrogenic keratectasia after LASIK and those with repeat grafts in case of “keratoconus recurrences” due to small grafts with thin host cornea. For donor trephination from the epithelial side, an artificial chamber is used. Wound closure is achieved with a double running cross-stitch suture according to Hoffmann. Graft size is adapted individually depending on corneal size („as large as possible – as small as necessary“). Limbal centration will be preferred intraoperatively due to optical displacement of the pupil. During the last 10 years femtosecond laser trephination has been introduced from the USA as a potentially advantageous approach. Results: Prospective clinical studies have shown that the technique of non-contact excimer laser PKP improves donor and recipient centration, reduces “vertical tilt” and “horizontal torsion” of the graft in the recipient bed, thus resulting in significantly less “all-sutures-out” keratometric astigmatism (2.8 vs. 5.7 D), higher regularity of the topography (SRI 0.80 vs. 0.98) and better visual acuity (0.80 vs. 0.63) in contrast to the motor trephine. The stage of the disease does not influence functional outcome after excimer laser PKP. Refractive outcomes of femtosecond laser

  15. Scattered UV irradiation during VISX excimer laser keratorefractive surgery.

    Science.gov (United States)

    Hope, R J; Weber, E D; Bower, K S; Pasternak, J P; Sliney, D H

    2008-04-01

    To evaluate the potential occupational health hazards associated with scattered ultraviolet (UV) radiation during photorefractive keratectomy (PRK) using the VISX Star S3 excimer laser. The Laser Vision Center, National Naval Medical Center, Bethesda, Maryland, USA. Intraoperative radiometric measurements were made with the Ophir Power/Energy Meter (LaserStar Model PD-10 with silicon detector) during PRK treatments as well as during required calibration procedures at a distance of 20.3 cm from the left cornea. These measurements were evaluated using a worst-case scenario for exposure, and then compared with the American Conference of Governmental Industrial Hygeinists (ACGIH) Threshold Value Limits (TVL) to perform a risk/hazard analysis. During the PRK procedures, the highest measured value was 248.4 nJ/pulse. During the calibration procedures, the highest measured UV scattered radiation level was 149.6 nJ/pulse. The maximum treatment time was 52 seconds. Using a worst-case scenario in which all treatments used the maximum power and time, the total energy per eye treated was 0.132 mJ/cm2 and the total UV radiation at close range (80 cm from the treated eye) was 0.0085 mJ/cm2. With a workload of 20 patients, the total occupational exposure at 80 cm to actinic UV radiation in an 8-hour period would be 0.425 mJ/cm2. The scattered actinic UV laser radiation from the VISX Star S3 excimer laser did not exceed occupational exposure limits during a busy 8-hour workday, provided that operating room personnel were at least 80 cm from the treated eye. While the use of protective eyewear is always prudent, this study demonstrates that the trace amounts of scattered laser emissions produced by this laser do not pose a serious health risk even without the use of protective eyewear.

  16. Excimer laser cleaning of mud stained paper and parchment

    Directory of Open Access Journals (Sweden)

    Duarte, J. P.

    1998-04-01

    Full Text Available The main advantage of excimer lasers when processing materials, its the emission of a radiation with wavelength in the ultraviolet region. This characteristic allows an extremely accurate and very well defined shape of material removal as well as total absence of heat affected zone and alterations in the material structure. In excimer laser paper and parchment cleaning, the mud is removed by breaking the physicalchemical bonding between this last one and the material to be cleaned not affecting neither its structure nor the chromatic pigment existing in some samples.

    A principal vantagem dos lasers de excímeros, no processamento de materiais, é a emissão de um feixe luminoso com comprimento de onda compreendido na região do ultravioleta, permitindo urna remoçao do material com precisão muito elevada e excelente definição de bordos, ausência de zona térmicamente afectada e ausência de alterações da estrutura. Na limpeza dos papéis e pergaminhos a lama é removida por quebra das ligações fisico-químicas entre a lama e o papel não se afectando a estrutura deste, assim como não se afectaram os pigmentos cromáticos existentes em algumas amostras.

  17. Recent developments on microablation of glass materials using excimer lasers

    Science.gov (United States)

    Tseng, Ampere A.; Chen, Ying-Tung; Chao, Choung-Lii; Ma, Kung-Jeng; Chen, T. P.

    2007-10-01

    For many years, the development of effective laser machining techniques for making glass-based microcomponents and devices has been a critical factor in the birth of new photonic and biomedical microsystems. In this article, the characteristics and abilities of excimer lasers for micromachining of a wide range of glass materials are reviewed and studied. Following the introduction, the special features of excimer lasers are discussed. The typical micromachining system used for glass materials is presented. Then, the fundamental micromachining parameters and the associated morphologies of machined surfaces are evaluated. The approaches by controlling the ablation rate for making the curve surfaces are specifically formulated. Although a wide range of commercially available glasses is covered in this article, two types of the most widely used glasses, borosilicate glass and fused silica, are thoroughly examined to illustrate the complexity in micromachining the glass materials. The procedures to machine single, arrayed, curved microstructures are described. The utilizations of these procedures for making microneedles, optical waveguides, submicron grating, and microlenses are specifically demonstrated. Finally, recommendations for future efforts are presented.

  18. Vitreoretinal surgery with the 193-nm excimer laser

    Science.gov (United States)

    Palanker, Daniel V.; Hemo, Itzhak; Turovets, Igor; Zauberman, Hanan; Lewis, Aaron

    1994-06-01

    The 193-nm excimer laser is known for its ability to precisely ablate soft biological tissues in the air environment with sub- micron depth control and sub-micron damage zones in the surrounding. The lack of a convenient delivery system and strong absorption of this radiation by biological liquids prevented, until recently, microsurgical applications of this laser. We have constructed special tips that are capable of delivering enough energy for effective removal of soft tissues in a strongly absorbing liquid environment. These tips attach to an articulated arm-based delivery system. This instrument was applied to vitreoretinal membranes removal. The accepted technique for these membranes removal is mechanical peeling and cutting which is associated with strong traction of the retina and this occasionally results in retinal damage. It was demonstrated in this study that the 193-nm excimer laser is capable of safely and precisely cutting and ablating these membranes which enable their removal without exerting any tractional forces on the retina. The effective cutting regime of retina and vitreoretinal membranes occurred at energy fluence of about 250- to 350-mJ/cm2/pulse with a corresponding cutting depth of 50 to 150 micrometers /pulse. The results obtained in this study suggest that this technology could be applicable to a wide variety of intraocular procedures.

  19. Laser drilling of metals with a XeCl excimer laser

    NARCIS (Netherlands)

    Schoonderbeek, A.

    2005-01-01

    This thesis is about laser drilling with a unique excimer laser with a nearly diffraction-limited beam and relatively long optical pulse duration of 175 ns. The combination of high processing speed and high processing quality suitable for industrial applications can be obtained because the excellent

  20. EXCIMER-LASER ABLATION OF SOFT-TISSUE - A STUDY OF THE CONTENT OF RAPIDLY EXPANDING AND COLLAPSING BUBBLES

    NARCIS (Netherlands)

    van Leeuwen, T. G.; Jansen, E. D.; Motamedi, M.; Welch, A. J.; Borst, C.

    1994-01-01

    Both holmium (lambda = 2.09 mum) and excimer (lambda = 308 nm) lasers are used for ablation of tissue. In a previous study, excimer laser ablation of aorta produced rapidly expanding and collapsing vapor bubbles. To investigate whether the excimer-induced bubble is caused by vaporization of (tissue)

  1. Low threshold buried-heterostructure quantum well lasers by excimer laser assisted disordering

    Energy Technology Data Exchange (ETDEWEB)

    Epler, J.E.; Thornton, R.L.; Mosby, W.J.; Paoli, T.L.

    1988-10-17

    Laser assisted disordering based upon a direct-write Ar/sup +/ laser beam has been established as a fabrication technique for high quality optoelectronic devices. In this letter, we report a new form of laser assisted disordering in which an excimer laser beam, photolithographically patterned, is used to define the incorporation of Si impurity into GaAs-AlGaAs heterostructure crystals. During a subsequent thermal anneal the diffusing Si induces layer disordering to a depth of approx.1 ..mu..m. The excimer laser assisted disordering process is characterized as a function of the energy density of the laser beam. Also, this technique is used to fabricate high quality buried-heterostructure lasers. With a reflective rear facet, the typical cw threshold current is 4 mA and the maximum power output is 27 mW. The devices exhibit single fundamental mode operation with subsidiary longitudinal side modes suppressed by 34 dB.

  2. Combination treatment with excimer laser and narrowband UVB light in vitiligo patients.

    Science.gov (United States)

    Shin, Sungsik; Hann, Seung-Kyung; Oh, Sang Ho

    2016-01-01

    For the treatment of vitiligo, narrowband UVB (NBUVB) light is considered the most effective for nonsegmental vitiligo, while excimer laser treatment is commonly used for localized vitiligo. However, treatment areas may potentially be missed with excimer laser treatment. We aimed to evaluate the effect of combinational treatment with NBUVB light and excimer laser on vitiligo. All patients were first treated with NBUVB; excimer laser was then applied in conjunction with NBUVB phototherapy due to a slow response or no further improvement with continuous NBUVB treatment alone. To minimize adverse effects, a fixed dose of NBUVB was administered, and the dose of excimer laser was increased based on patient response. Among 80 patients, 54 patients showed responses after combination with excimer laser; however, 26 patients (32.5%) showed no remarkable change after combination therapy. Of the 26 patients who showed no further response, 12 patients (46.1%) presented with vitiligo on the acral areas, which are known to the least responsive sites. Our study suggests that combined treatment of NBUVB and excimer laser in vitiligo may enhance the treatment response without remarkable side effects, therefore might also increase the compliance of the patients to the treatment. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Excimer laser ablation of polyimide: a 14-year IBM perspective

    Science.gov (United States)

    Brannon, James H.; Wassick, Thomas A.

    1997-05-01

    IBM introduced the first commercial high-end mainframe computer system incorporating laser ablation technology in 1991. This milestone was the culmination of nearly a decade of scientific, engineering, and manufacturing effort. Extensive research and development on 308 nm laser ablation of polyimide lead to the first IBM prototype ablation tool in 1987 for the production of via-holes in thin film packaging structures. This prototype, similar to step and repeat photolithography systems, evolved into full-scale manufacturing tools which utilize sophisticated beam shaping, beam homogenizing, and projection optics. But the maturity of this technology belies the fact that the scientific understanding of the laser ablation process is still far from complete. This paper briefly reviews the engineering and scientific accomplishments, both within and external to IBM, that lead to the commercial utilization of the laser ablation process. Current technical tissues are discussed, in addition to alternative IBM applications of polyimide ablation. The paper concludes by discussing the relative merits of excimer vs. solid-state lasers, and how each may impact future manufacturing technology.

  4. Study on the excimer laser annealed amorphous hydrogenated silicon carbon films deposited by PECVD

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosone, G. [CNR-INFM CRS-Coherentia, Complesso Universitario MSA, Napoli (Italy); Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Complesso Universitario MSA, Napoli (Italy); Basa, D.K. [Utkal University, Bhubaneswar (India); Coscia, U. [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Complesso Universitario MSA, Napoli (Italy); CNISM Unita' di Napoli, Complesso Universitario MSA, Napoli (Italy); Tresso, E.; Celasco, E. [Dipartimento di Scienza dei Materiali ed Ingegneria Chimica, Politecnico di Torino (Italy); Chiodoni, A. [Materials and Microsystems Laboratory, chi-LAB, Politecnico di Torino (Italy); Pinto, N.; Murri, R. [Dipartimento di Fisica, Universita' di Camerino (Italy)

    2010-04-15

    Hydrogenated amorphous silicon carbon films of different carbon content were deposited by plasma enhanced chemical vapour deposition at low substrate temperature (200 C) and were subjected to excimer laser annealing. X-ray diffraction spectra and field emission scanning electron microscopy images demonstrate that carbon content plays an important role in facilitating the crystallization process induced by the excimer laser treatment (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  5. Shadowgraphic imaging of metal drilling with a long pulse excimer laser

    NARCIS (Netherlands)

    Schoonderbeek, A.; Biesheuvel, C.A.; Hofstra, R.M.; Boller, Klaus J.; Meijer, J.; Miyamoto, Isamu; Ostendorf, Andreas; Sugioka, Koji; Helvajian, Henry

    2003-01-01

    A shadowgraphic imaging technique is used for studying the interaction between the laser beam and the material during laser drilling. The used laser is a XeCl excimer laser with a nearly diffraction limited beam and 175 ns pulse length. We studied how and when the material is removed. Holes are

  6. Advanced excimer laser technologies enable green semiconductor manufacturing

    Science.gov (United States)

    Fukuda, Hitomi; Yoo, Youngsun; Minegishi, Yuji; Hisanaga, Naoto; Enami, Tatsuo

    2014-03-01

    "Green" has fast become an important and pervasive topic throughout many industries worldwide. Many companies, especially in the manufacturing industries, have taken steps to integrate green initiatives into their high-level corporate strategies. Governments have also been active in implementing various initiatives designed to increase corporate responsibility and accountability towards environmental issues. In the semiconductor manufacturing industry, there are growing concerns over future environmental impact as enormous fabs expand and new generation of equipments become larger and more powerful. To address these concerns, Gigaphoton has implemented various green initiatives for many years under the EcoPhoton™ program. The objective of this program is to drive innovations in technology and services that enable manufacturers to significantly reduce both the financial and environmental "green cost" of laser operations in high-volume manufacturing environment (HVM) - primarily focusing on electricity, gas and heat management costs. One example of such innovation is Gigaphoton's Injection-Lock system, which reduces electricity and gas utilization costs of the laser by up to 50%. Furthermore, to support the industry's transition from 300mm to the next generation 450mm wafers, technologies are being developed to create lasers that offer double the output power from 60W to 120W, but reducing electricity and gas consumption by another 50%. This means that the efficiency of lasers can be improve by up to 4 times in 450mm wafer production environments. Other future innovations include the introduction of totally Heliumfree Excimer lasers that utilize Nitrogen gas as its replacement for optical module purging. This paper discusses these and other innovations by Gigaphoton to enable green manufacturing.

  7. Microencapsulation of silicon cavities using a pulsed excimer laser

    KAUST Repository

    Sedky, Sherif M.

    2012-06-07

    This work presents a novel low thermal-budget technique for sealing micromachined cavities in silicon. Cavities are sealed without deposition, similar to the silicon surface-migration sealing process. In contrast to the 1100°C furnace anneal required for the migration process, the proposed technique uses short excimer laser pulses (24ns), focused onto an area of 23mm 2, to locally heat the top few microns of the substrate, while the bulk substrate remains near ambient temperature. The treatment can be applied to selected regions of the substrate, without the need for special surface treatments or a controlled environment. This work investigates the effect of varying the laser pulse energy from 400 mJ cm 2to 800 mJ cm 2, the pulse rate from 1Hz to 50Hz and the pulse count from 200 to 3000 pulses on sealing microfabricated cavities in silicon. An analytical model for the effect of holes on the surface temperature distribution is derived, which shows that much higher temperatures can be achieved by increasing the hole density. A mechanism for sealing the cavities is proposed, which indicates how complete sealing is feasible. © 2012 IOP Publishing Ltd.

  8. LASIK ablation centration: an objective digitized assessment and comparison between two generations of an excimer laser.

    Science.gov (United States)

    Kanellopoulos, Anastasios John; Asimellis, George

    2015-03-01

    To objectively define the effective centration of myopic femtosecond laser-assisted LASIK ablation pattern, evaluate the difference between achieved versus planned excimer laser ablation centration, and compare these results from two different generations of an excimer laser system. The study retrospectively evaluated 280 eyes subjected to myopic LASIK. Digital image analysis was performed on Scheimpflug sagittal curvature maps (difference of preoperative to postoperative). Centration was assessed via proprietary software digital analysis of the coordinate displacement between the achieved ablation geometric center and the planned ablation center, which was the corneal vertex. Results from two different excimer laser generations (Eye-Q 400 [140 eyes] and EX500 [140 eyes]; Alcon/WaveLight, Fort Worth, TX) were compared. Radial displacement was on average 360 ± 220 µm (range: 0 to 1,030 µm) in the Eye-Q 400 laser group and 120 ± 110 µm (range: 0 to 580 µm) in the EX500 laser group (P laser group and 4% in the EX500 laser group. Displacement of ablation pattern may depend on the laser platform used. The improvement in the efficiency of centration indicates that newer generation excimer lasers with faster eye tracking and active centration control appear to achieve a significantly more accurate centration of myopic ablation patterns. The authors propose this novel, objective technique for laser refractive surgeon evaluation may point out significant outcome measures not currently used in standard metrics of refractive laser efficiency. Copyright 2015, SLACK Incorporated.

  9. Average power scaling of UV excimer lasers drives flat panel display and lidar applications

    Science.gov (United States)

    Herbst, Ludolf; Delmdahl, Ralph F.; Paetzel, Rainer

    2012-03-01

    Average power scaling of 308nm excimer lasers has followed an evolutionary path over the last two decades driven by diverse industrial UV laser microprocessing markets. Recently, a new dual-oscillator and beam management concept for high-average power upscaling of excimer lasers has been realized, for the first time enabling as much as 1.2kW of stabilized UV-laser average output power at a UV wavelength of 308nm. The new dual-oscillator concept enables low temperature polysilicon (LTPS) fabrication to be extended to generation six glass substrates. This is essential in terms of a more economic high-volume manufacturing of flat panel displays for the soaring smartphone and tablet PC markets. Similarly, the cost-effective production of flexible displays is driven by 308nm excimer laser power scaling. Flexible displays have enormous commercial potential and can largely use the same production equipment as is used for rigid display manufacturing. Moreover, higher average output power of 308nm excimer lasers aids reducing measurement time and improving the signal-to-noise ratio in the worldwide network of high altitude Raman lidar stations. The availability of kW-class 308nm excimer lasers has the potential to take LIDAR backscattering signal strength and achievable altitude to new levels.

  10. Time Evolution of the Excimer State of a Conjugated Polymer Laser

    Directory of Open Access Journals (Sweden)

    Wafa Musa Mujamammi

    2017-11-01

    Full Text Available An excited dimer is an important complex formed in nano- or pico-second time scales in many photophysics and photochemistry applications. The spectral and temporal profile of the excimer state of a laser from a new conjugated polymer, namely, poly (9,9-dioctylfluorenyl-2,7-diyl (PFO, under several concentrations in benzene were investigated. These solutions were optically pumped by intense pulsed third-harmonic Nd:YAG laser (355-nm to obtain the amplified spontaneous emission (ASE spectra of a monomer and an excimer with bandwidths of 6 and 7 nm, respectively. The monomer and excimer ASEs were dependent on the PFO concentration, pump power, and temperature. Employing a sophisticated picosecond spectrometer, the time evolution of the excimer state of this polymer, which is over 400 ps, can be monitored.

  11. Epithelial healing and clinical outcomes in excimer laser photorefractive surgery following three epithelial removal techniques: mechanical, alcohol, and excimer laser.

    Science.gov (United States)

    Lee, Hyung Keun; Lee, Kyung Sub; Kim, Jin Kook; Kim, Hyeon Chang; Seo, Kyung Ryul; Kim, Eung Kweon

    2005-01-01

    To evaluate epithelial healing, postoperative pain, and visual and refractive outcomes after photorefractive keratectomy (PRK) using three epithelial removal techniques. Prospective, nonrandomized, comparative trial. Department of Ophthalmology, Yonsei University College of Medicine and Balgensesang Ophthalmology Clinic, Seoul, Korea. For the PRK procedure, the corneal epithelium was removed in one of three ways: mechanically (conventional PRK [PRK]) in 88 eyes of 44 patients; using excimer laser (transepithelial PRK [tPRK]) in 106 eyes of 53 patients; or using 20% diluted alcohol, laser-assisted subepithelial keratomileusis (LASEK) in 106 eyes of 53 patients. Epithelial healing, postoperative pain, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and remaining refractive error. The mean postoperative pain scores were 4.84 +/- 1.45 for PRK, 4.71 +/- 1.62 for tPRK, and 4.63 +/- 1.52 for LASEK (P = .125). The mean epithelial healing rates were 12.3 +/- 4.6 for PRK, 15.2 +/- 4.9 for tPRK, and 18.1 +/- 5.2 mm2/day for LASEK (P refractive outcomes. Using the same nomogram, tPRK resulted in a slight overcorrection, and LASEK resulted in a slight undercorrection.

  12. All-Solid-State Drivers for High Power Excimer Lasers Used in Projection Gas Immersion Laser Doping

    National Research Council Canada - National Science Library

    Jacob, Jonah

    2001-01-01

    .... P-GILD uses a pulsed, 200-watt-class excimer laser as an illumination source to produce ultra-shallow, low-sheet resistance, box-like and retrograde impurity profiles in silicon without the use...

  13. A comparison of the characteristics of excimer and femtosecond laser ablation of acrylonitrile butadiene styrene (ABS)

    Energy Technology Data Exchange (ETDEWEB)

    See, Tian Long, E-mail: tianlong.see@postgrad.manchester.ac.uk [Corrosion and Protection Centre, School of Materials, The Mill, The University of Manchester, M13 9PL Manchester (United Kingdom); Laser Processing Research Centre, School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL Manchester (United Kingdom); Liu, Zhu [Corrosion and Protection Centre, School of Materials, The Mill, The University of Manchester, M13 9PL Manchester (United Kingdom); Li, Lin [Laser Processing Research Centre, School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL Manchester (United Kingdom); Zhong, Xiang Li [Corrosion and Protection Centre, School of Materials, The Mill, The University of Manchester, M13 9PL Manchester (United Kingdom)

    2016-02-28

    Highlights: • Ablation threshold for excimer laser is lower compared to femtosecond laser. • Effective optical penetration depth for excimer laser is lower compared to femtosecond laser. • Two ablation characteristic regimes are observed for femtosecond laser ablation. • Reduction of C=C bond following excimer or fs laser ablation is observed. • Addition of oxygen- and nitrogen-rich functional groups is observed. - Abstract: This paper presents an investigation on the ablation characteristics of excimer laser (λ = 248 nm, τ = 15 ns) and femtosecond laser (λ = 800 nm, τ = 100 fs) on ABS polymer sheets. The laser–material interaction parameters (ablation threshold, optical penetration depth and incubation factor) and the changes in material chemical properties were evaluated and compared between the two lasers. The work shows that the ablation threshold and effective optical penetration depth values are dependent on the wavelength of laser beam (photon energy) and the pulse width. The ablation threshold value is lower for the excimer laser ablation of ABS (F{sub th} = 0.087 J/cm{sup 2}) than that for the femtosecond laser ablation of ABS (F{sub th} = 1.576 J/cm{sup 2}), demonstrating a more dominating role of laser wavelength than the pulse width in influencing the ablation threshold. The ablation depth versus the logarithmic scale of laser fluence shows two linear regions for the fs laser ablation, not previously known for polymers. The effective optical penetration depth value is lower for excimer laser ablation (α{sup −1} = 223 nm) than that for femtosecond laser ablation (α{sup −1} = 2917 nm). The ablation threshold decreases with increasing number of pulses (NOP) due to the chain scission process that shortens the polymeric chains, resulting in a weaker polymeric configuration and the dependency is governed by the incubation factor. Excimer laser treatment of ABS eliminates the C=C bond completely through the chain scission process whereas

  14. KrF excimer laser precision machining of hard and brittle ceramic biomaterials.

    Science.gov (United States)

    Huang, Yao-Xiong; Lu, Jian-Yi; Huang, Jin-Xia

    2014-06-01

    KrF excimer laser precision machining of porous hard-brittle ceramic biomaterials was studied to find a suitable way of machining the materials into various desired shapes and sizes without distorting their intrinsic structure and porosity. Calcium phosphate glass ceramics (CPGs) and hydroxyapatite (HA) were chosen for the study. It was found that KrF excimer laser can cut both CPGs and HA with high efficiency and precision. The ablation rates of CPGs and HA are respectively 0.081 µm/(pulse J cm(-2)) and 0.048 µm/(pulse  J cm(-2)), while their threshold fluences are individually 0.72 and 1.5 J cm(-2). The cutting quality (smoothness of the cut surface) is a function of laser repetition rate and cutting speed. The higher the repetition rate and lower the cutting speed, the better the cutting quality. A comparison between the cross sections of CPGs and HA cut using the excimer laser and using a conventional diamond cutting blade indicates that those cut by the excimer laser could retain their intrinsic porosity and geometry without distortion. In contrast, those cut by conventional machining had distorted geometry and most of their surface porosities were lost. Therefore, when cutting hard-brittle ceramic biomaterials to prepare scaffold and implant or when sectioning them for porosity evaluation, it is better to choose KrF excimer laser machining.

  15. High efficiency metal marking with CO2 laser and glass marking with excimer laser

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1997-01-01

    with a thoroughly tested ray-tracing model is presented and compared with experimental results. Special emphasis is put on two different applications namely marking in metal with TEA-CO2 laser and marking in glass with excimer laser. The results are evaluated on the basis of the achievable energy enhancement......Today, mask based laser materials processing and especially marking is widely used. However, the energy efficiency in such processes is very low [1].This paper gives a review of the results, that may be obtained using the energy enhancing technique [1]. Results of simulations performed...

  16. Performance characteristics of an excimer laser (XeCl) with single ...

    Indian Academy of Sciences (India)

    Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression suitable for material processing applications are presented here. The laser incorporates in-built compact gas circulation and gas cooling to ensure fresh gas mixture between the electrodes for repetitive operation.

  17. Performance characteristics of an excimer laser (XeCl) with single ...

    Indian Academy of Sciences (India)

    2017-01-10

    Jan 10, 2017 ... Abstract. Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compres- sion suitable for material processing applications are presented here. The laser incorporates in-built compact gas circulation and gas cooling to ensure fresh gas mixture between the electrodes for ...

  18. Mesoscale Laser Processing using Excimer and Short-Pulse Ti: Sapphire Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Shirk, M D; Rubenchik, A M; Gilmer, G H; Stuart, B C; Armstrong, J P; Oberhelman, S K; Baker, S L; Nikitin, A J; Mariella, R P

    2003-07-28

    Targets to study high-energy density physics and inertial confinement fusion processes have very specific and precise tolerances that are pushing the state-of-the-art in mesoscale microsculpting technology. A significant effort is required in order to advance the capabilities to make these targets with very challenging geometries. Ultrashort pulsed (USP) Ti:Sapphire lasers and excimer lasers are proving to be very effective tools in the fabrication of the very small pieces that make up these targets. A brief description of the dimensional and structural requirements of these pieces will be presented, along with theoretical and experimental results that demonstrate to what extent these lasers are achieving the desired results, which include sub-{mu}m precision and RMS surface values well below 100 nm. This work indicates that excimer lasers are best at sculpting the polymer pieces and that the USP lasers work quite well on metal and aerogel surfaces, especially for those geometries that cannot be produced using diamond machining and where material removal amounts are too great to do with focused ion beam milling in a cost effective manner. In addition, the USP laser may be used as part of the procedure to fill target capsules with fusion fuel, a mixture of deuterium and tritium, without causing large perturbations on the surface of the target by keeping holes drilled through 125 {micro}m of beryllium below 5 {micro}m in diameter.

  19. Excimer laser-induced metallization for in situ processing on Si and GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, Michel; Suys, Marc; Tabbal, Maleck; Izquierdo, Ricardo; Yelon, Arthur; Sacher, Edward (Groupe des Couches Minces and Dept. de Genie Physique, Ecole Polytechnique de Montreal, Station ' A' , Montreal, Quebec (Canada))

    1994-05-15

    We have investigated both the large area excimer laser-induced deposition of W and its silicides on GaAs to form thermally stable Schottky contacts, and the reduction of a Cu(I) compound for the deposition of Cu interconnects for Si microelectronics. Using a KrF excimer laser at 25 mJ/cm[sup 2] and a mixture of WF[sub 6], SiH[sub 4] and Ar, metallic W is deposited with an average growth rate of 1 A/pulse. For Cu deposition, the reduction by H[sub 2] of the precursor Cu(hfac)(TMVS) under a KrF excimer laser illumination of 9 mJ/cm[sup 2] gives metallic Cu with a Cu/C ratio of 4.35. For both processes, possible deposition mechanisms are discussed in terms of gas phase and surface reactions

  20. A comparison of the characteristics of excimer and femtosecond laser ablation of acrylonitrile butadiene styrene (ABS)

    Science.gov (United States)

    See, Tian Long; Liu, Zhu; Li, Lin; Zhong, Xiang Li

    2016-02-01

    This paper presents an investigation on the ablation characteristics of excimer laser (λ = 248 nm, τ = 15 ns) and femtosecond laser (λ = 800 nm, τ = 100 fs) on ABS polymer sheets. The laser-material interaction parameters (ablation threshold, optical penetration depth and incubation factor) and the changes in material chemical properties were evaluated and compared between the two lasers. The work shows that the ablation threshold and effective optical penetration depth values are dependent on the wavelength of laser beam (photon energy) and the pulse width. The ablation threshold value is lower for the excimer laser ablation of ABS (Fth = 0.087 J/cm2) than that for the femtosecond laser ablation of ABS (Fth = 1.576 J/cm2), demonstrating a more dominating role of laser wavelength than the pulse width in influencing the ablation threshold. The ablation depth versus the logarithmic scale of laser fluence shows two linear regions for the fs laser ablation, not previously known for polymers. The effective optical penetration depth value is lower for excimer laser ablation (α-1 = 223 nm) than that for femtosecond laser ablation (α-1 = 2917 nm). The ablation threshold decreases with increasing number of pulses (NOP) due to the chain scission process that shortens the polymeric chains, resulting in a weaker polymeric configuration and the dependency is governed by the incubation factor. Excimer laser treatment of ABS eliminates the Cdbnd C bond completely through the chain scission process whereas Cdbnd C bond is partially eliminated through the femtosecond laser treatment due to the difference in photon energy of the two laser beams. A reduction in the Cdbnd C bond through the chain scission process creates free radical carbons which then form crosslinks with each other or react with oxygen, nitrogen and water in air producing oxygen-rich (Csbnd O and Cdbnd O bond) and nitrogen-rich (Csbnd N) functional groups.

  1. Discharge instabilities in high-pressure fluorine based excimer laser gas mixtures

    NARCIS (Netherlands)

    Mathew, D.

    2007-01-01

    Fluorine based excimer lasers such as KrF, ArF and F2 are currently the most powerful sources available in the ultraviolet wavelength range, operating at 248 nm, at 193 nm and at 157 nm, respectively. They are thus of central importance for numerous applications in this range. At these short

  2. A new method for three dimensional excimer laser micromachining, Hole Area Modulation (HAM)

    NARCIS (Netherlands)

    Masuzawa, T.; Olde Benneker, Jeroen; Eindhoven, J.J.C.

    2000-01-01

    A new excimer laser system configuration for three dimensional (3D) micromachining, called Hole Area Modulation (HAM) method, is proposed and the feasibility of the system is experimentally confirmed. In this method, information on the depth of machining is converted to the sizes of small holes in

  3. Saline flush during excimer laser angioplasty: short and long term effects in the rabbit femoral artery

    NARCIS (Netherlands)

    van Leeuwen, T. G.; Velema, E.; Pasterkamp, G.; Post, M. J.; Borst, C.

    1998-01-01

    BACKGROUND AND OBJECTIVE: In this study, the effect of flushing saline on arterial wall damage (medial ruptures and necrosis), intimal hyperplasia, and arterial remodeling was determined. During excimer laser coronary angioplasty saline is flushed to reduce the size of explosive water vapor bubbles

  4. Preionization and gain studies in fluorine based excimer laser gas discharges

    NARCIS (Netherlands)

    Azarov, A.V.

    2008-01-01

    Fluorine-based excimer gas lasers are powerful sources of coherent radiation in the UV and VUV part of the electro-magnetic spectrum. Due to their short wavelengths and high output power they are widely employed in high resolution material processing like micromachining and in lithography. In this

  5. Refractive microlenses produced by excimer laser machining of poly(methyl methacrylate)

    DEFF Research Database (Denmark)

    Jensen, Martin Frøhling; Krühne, Ulrich; H., L.

    2005-01-01

    A method has been developed whereby refractive microlenses can be produced in poly (methyl methacrylate) by excimer laser irradiation at λ = 248 nm. The lenses are formed by a combined photochemical and thermal process. The lenses are formed as depressions in the substrate material (negative foca...

  6. Mechanism of injurious effect of excimer (308 nm) laser on the cell

    Science.gov (United States)

    Nevorotin, Alexey J.; Kallikorm, A. P.; Zeltzer, Gregory L.; Kull, Mart M.; Mihkelsoo, Virgo T.

    1991-06-01

    A Lameta 22710 excimer laser operating at 70 mJ/mm2 per pulse, with pulse duration of 70 nsec, and pulse repetition rate of 10 Hz, equipped with a quartz filament as energy conductor was used to make incisions on rat liver. 2 to 5 sec after irradiation the specimens were fixed and further processed for electron microscopy and histochemical visualization of the endoplasmic reticulum (ER) marker enzyme glucose-6- phosphatase at the ultrastructural level. The additional series were: fixation before irradiation-(A); lasing with Nd:YAG laser (1064 nm, continuous wave mode, 40 J/mm2)-(B); incision with a white-hot steel needle-(C); and incision with an Esto-Rex ultrasound scalpel (66 kHz, 6 Wt, vibration amplitude of 15 micrometers )-(D). The results showed that unlike Series C and B, in which high temperature caused severe damage to all cellular organellae, the excimer action was much more specific. It caused vesiculation of ER without significant injuries to other cellular structures. The analogous effect was noted after US scalpel cutting, thereby allowing a conclusion that a kind of dynamic rather than thermal factor is responsible for the observed phenomenon of vesiculation. The time schedule of vesicle formation and molecular background of membrane transformation is considered in the light of the data of Series A and D, and also on the basis of available information of membrane behavior. Photoablative effect of pulsed excimer laser is thought to be based on chemical decomposition of organic molecules and their ejection from the tissue to the action of high energy photons. Pressure waves (either acoustic or shock) are presumably generated powerful enough to cause tissue and cell damage beyond the site of ablation. Some thermal and fluorescence events are also implicative in biological targets irradiated with excimer lasers. In our previous studies electron histochemistry was employed for the analysis of cellular alterations caused with a continuous wave mode

  7. Preionization and gain studies in fluorine based excimer laser gas discharges

    OpenAIRE

    Azarov, A.V.

    2008-01-01

    Fluorine-based excimer gas lasers are powerful sources of coherent radiation in the UV and VUV part of the electro-magnetic spectrum. Due to their short wavelengths and high output power they are widely employed in high resolution material processing like micromachining and in lithography. In this field pattern sizes several times shorter than the used wavelength can be achieved using an immersion technique. However due to the short duration of the laser pulse (typically of few tens of ns for...

  8. A design of energy detector for ArF excimer lasers

    Science.gov (United States)

    Feng, Zebin; Han, Xiaoquan; Zhou, Yi; Bai, Lujun

    2017-08-01

    ArF excimer lasers with short wavelength and high photon energy are widely applied in the field of integrated circuit lithography, material processing, laser medicine, and so on. Excimer laser single pulse energy is a very important parameter in the application. In order to detect the single pulse energy on-line, one energy detector based on photodiode was designed. The signal processing circuit connected to the photodiode was designed so that the signal obtained by the photodiode was amplified and the pulse width was broadened. The amplified signal was acquired by a data acquisition card and stored in the computer for subsequent data processing. The peak of the pulse signal is used to characterize the single pulse energy of ArF excimer laser. In every condition of deferent pulse energy value levels, a series of data about laser pulses energy were acquired synchronously using the Ophir energy meter and the energy detector. A data set about the relationship between laser pulse energy and the peak of the pulse signal was acquired. Then, by using the data acquired, a model characterizing the functional relationship between the energy value and the peak value of the pulse was trained based on an algorithm of machine learning, Support Vector Regression (SVR). By using the model, the energy value can be obtained directly from the energy detector designed in this project. The result shows that the relative error between the energy obtained by the energy detector and by the Ophir energy meter is less than 2%.

  9. Comparison of femtosecond and excimer laser platforms available for corneal refractive surgery.

    Science.gov (United States)

    Chen, Lisa Y; Manche, Edward E

    2016-07-01

    The evolution of laser technology has left today's refractive surgeon with a choice between multiple laser platforms. The purpose of this review is to compare currently available femtosecond and excimer laser platforms, providing a summary of current evidence. Femtosecond lasers create LASIK flaps with better accuracy, uniformity, and predictability than mechanical microkeratomes. Newer higher-frequency femtosecond platforms elicit less inflammation, producing better visual outcomes. SMILE achieved similar safety, efficacy, and predictability as LASIK with greater preservation of corneal nerves and biomechanical strength. The emergence of wavefront technology has resulted in improved excimer laser treatments. Comparisons of wavefront-guided and wavefront-optimized treatments suggest that there is an advantage to using wavefront-guided platforms in terms of visual acuity and quality of vision. Topography-guided ablations are another well tolerated and effective option, especially in eyes with highly irregular corneas. Advances in femtosecond and excimer laser technology have not only improved the safety and efficacy of refractive procedures, but have also led to the development of promising new treatment modalities, such as SMILE and the use of wavefront-guided and topography-guided ablation. Future studies and continued technological progress will help to better define the optimal use of these treatment platforms.

  10. Excimer laser absorption on PMMA plate and on cornea: a practical approach using volume luminance

    Science.gov (United States)

    Digulescu, Petre P.; Carstocea, Benone D.; Sterian, Livia

    2001-04-01

    Excimer laser refractive surgery used in Ophthalmology in order to treat the human eye refraction problems has been performed over 10 years around the world. However a systematic approach of the physical phenomena and especially of the absorption on the cornea during the laser treatment is missing in the literature and the doctors are usually using empiric nomograms in order to achieve good results. The theoretical approach is difficult because of the complexity of the phenomena interconnected each to the others. The UV excimer laser beam used to controllably ablate the cornea is highly absorbed in the air and also is supplementary absorbed in the plume generated almost instantaneous as consequence of the ablation on the cornea. Because of this non-linear proces the energy of the laser beam delivered to the eye must be calibrated before each intervention on a patient. The purpose of the present work is to develop a mathematical model of the excimer laser absorption on PMMA and on human cornea based on a new physical notion, the Volume Luminance. The Volume Luminance is defined as volume density of the intensity of laser radiation. A brief theory of the Volume Luminance is also presented.

  11. Color-center laser spectroscopy of transient species produced by excimer-laser flash photolysis

    Energy Technology Data Exchange (ETDEWEB)

    Adams, H.; Hall, J.L.; Rusell, L.A.; Kasper, J.V.V.; Tittel, F.K.; Curl, R.F.,JR.

    1985-05-01

    Kinetic spectroscopy based on excimer-laser flash photolysis and color-center-laser (CCL) infrared probing is explored. In simiple absorption, the achievable signal-to-noise ratio (S/N) is not satisfactory even though the signal itself (corresponding to greater than 1 percent absorption) is fairly large. This is due to amplitude fluctuations of the CCL. By using a double-beam detection scheme to balance out these amplitude fluctuations the sensitivity can be improved to the extent that a 1 percent absorption gives a S/N approximately 100. In certain situations transient decreases in absorption of the precursor and transient increases in absorption due to final product formation can produce severe interferinng signals even in simple systems. This problem is overcome without a major loss in sensitivity by a recently developed 45 deg magnetic rotation scheme. These points are illustrated with spectra of Br, OH, and NH2. 21 references.

  12. High Efficiency Mask Based Laser Materials Processing with TEA-CO2 - and Excimer Laser

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1997-01-01

    In general, mask based laser materials processing techniques suffer from a very low energy efficiency. We have developed a simple device called an energy enhancer, which is capable of increasing the energy efficiency of typical mask based laser materials processing systems. A short review of the ...... line marking with TEA-CO2 laser of high speed canning lines. The second one is manufactured for marking or microdrilling with excimer laser.......In general, mask based laser materials processing techniques suffer from a very low energy efficiency. We have developed a simple device called an energy enhancer, which is capable of increasing the energy efficiency of typical mask based laser materials processing systems. A short review...... of the most widely used applications of these systems is given and the potential advantages of the energy enhancer are discussed.The basic principle behind the energy enhancing technique is explained and two new energy enhancers are presented and evaluated. The first one is designed especially for single text...

  13. Curative effects of excimer laser corneal refractive surgery for hyperopic anisometropic amblyopia

    Directory of Open Access Journals (Sweden)

    Xin-Gang Nie

    2017-07-01

    Full Text Available AIM: To investigate curative effects of excimer laser corneal refractive surgery for adults or older adolescent with hyperopic anisometropic amblyopia. METHODS: From March 2014 to March 2016, we selected 26 cases 26 eyes of adults or older adolescent with hyperopic anisometropic amblyopia in our hospital. All eyes underwent laser in situ keratomileusis, observed for the uncorrected visual acuity(UCVA, best corrected visual acuity(BCVA, diopter and stereopsis. RESULTS: At the end of the follow-up, the patient's spherical equivalent and anisometropia were 1.47±0.51D and 1.15±0.22D, were significantly lower than that before operation(PPPCONCLUSION: In adult or older adolescent with hyperopic anisometropic amblyopia, excimer laser corneal refractive surgery has a certain effect.

  14. Transformation of microcrystalline silicon films by excimer-laser-induced crystallization

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, I.-C. [Department of Electrical Engineering, Da-Yeh University, Changhua 515, Taiwan (China); Lien, S.-Y. [Department of Materials Engineering, National Chung Hsing University, 250 Kuo Kuang Rd., Taichung Taiwan 402, (China); Wuu, D.-S. [Department of Materials Engineering, National Chung Hsing University, 250 Kuo Kuang Rd., Taichung Taiwan 402 (China)]. E-mail: dsw@dragon.nchu.edu.tw

    2005-02-01

    We describe the excimer-laser-induced crystallization of microcrystalline silicon films deposited by plasma-enhanced chemical vapor deposition (PECVD). Microcrystalline silicon films containing 2 at.% hydrogen can be used as precursor films for the laser recrystallization process without a dehydrogenation step, and provide a wider laser energy fluence process window than the previous explosive recrystallization for low temperature polysilicon (poly-Si) thin-film transistor (TFT) fabrication. Ellipsometry, transmission electron microscopy (TEM), and atomic force microscopy (AFM) are used to evaluate the laser irradiated films. Specially, we describe using atomic force microscopy to obtain plane-view grain microstructure images.

  15. Application of optical tweezers and excimer laser to study protoplast fusion

    Science.gov (United States)

    Kantawang, Titirat; Samipak, Sompid; Limtrakul, Jumras; Chattham, Nattaporn

    2015-07-01

    Protoplast fusion is a physical phenomenon that two protoplasts come in contact and fuse together. Doing so, it is possible to combine specific genes from one protoplast to another during fusion such as drought resistance and disease resistance. There are a few possible methods to induce protoplast fusion, for example, electrofusion and chemical fusion. In this study, chemical fusion was performed with laser applied as an external force to enhance rate of fusion and observed under a microscope. Optical tweezers (1064 nm with 100X objective N.A. 1.3) and excimer laser (308 nm LMU-40X-UVB objective) were set with a Nikon Ti-U inverted microscope. Samples were prepared by soaking in hypertonic solution in order to induce cell plasmolysis. Elodea Canadensis and Allium cepa plasmolysed leaves were cut and observed under microscope. Concentration of solution was varied to induce difference turgor pressures on protoplasts pushing at cell wall. Free protoplasts in solution were trapped by optical tweezers to study the effect of Polyethylene glycol (PEG) solution. PEG was diluted by Ca+ solution during the process to induced protoplast cell contact and fusion. Possibility of protoplast fusion by excimer laser was investigated and found possible. Here we report a novel tool for plant cell fusion using excimer laser. Plant growth after cell fusion is currently conducted.

  16. Study on the electromagnetic radiation characteristics of discharging excimer laser system

    Science.gov (United States)

    Zhao, Duliang; Liang, Xu; Fang, Xiaodong; Wang, Qingsheng

    2016-10-01

    Excimer laser in condition of high voltage, large current and fast discharge will produce strong electromagnetic pulse radiation and electromagnetic interference on the around electrical equipment. The research on characteristics and distribution of excimer laser electromagnetic radiation could provide important basis for electromagnetic shielding and suppressing electromagnetic interference, and further improving the electromagnetic compatibility of system. Firstly, electromagnetic radiation source is analyzed according to the working principle of excimer laser. The key test points of the electromagnetic radiation, hydrogen thyratron, main discharge circuit and laser outlet, are determined by the mechanical structure and the theory of electromagnetic radiation. Secondly, characteristics of electromagnetic field were tested using a near field probe on the key positions of the vertical direction at 20, 50, and 80 cm, respectively. The main radiation frequencies and the radiation field characteristics in the near field are obtained. The experimental results show that the main radiation frequencies distribute in 47, 65, and 130 MHz for electric field and the main radiation frequencies distribute in 34, 100, and 165 MHz for magnetic field. The intensity of electromagnetic field decreases rapidly with the increase of test distance. The higher the frequency increases, the faster the amplitude attenuate. Finally, several electromagnetic interference suppression measurement methods are proposed from the perspective of electromagnetic compatibility according to the test results.

  17. Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia.

    Science.gov (United States)

    Barsam, Allon; Allan, Bruce D S

    2014-06-17

    Myopia is a condition in which the focusing power (refraction) of the eye is greater than that required for clear distance vision. There are two main types of surgical correction for moderate to high myopia; excimer laser and phakic intraocular lenses (IOLs). Excimer laser refractive surgery for myopia works by removing corneal stroma to lessen the refractive power of the cornea and to bring the image of a viewed object into focus onto the retina rather than in front of it. Phakic IOLs for the treatment of myopia work by diverging light rays so that the image of a viewed object is brought into focus onto the retina rather than in front of the retina. They can be placed either in the anterior chamber of the eye in front of the iris or in the posterior chamber of the eye between the iris and the natural lens. To compare excimer laser refractive surgery and phakic IOLs for the correction of moderate to high myopia by evaluating postoperative uncorrected visual acuity, refractive outcome, potential loss of best spectacle corrected visual acuity (BSCVA) and the incidence of adverse outcomes. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 1), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to February 2014), EMBASE (January 1980 to February 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 11 February 2014. We included randomised controlled trials (RCTs) comparing excimer laser refractive surgery and phakic IOLs for the correction of myopia greater than 6.0 diopters (D) spherical equivalent. Two authors independently

  18. Discharge instabilities in high-pressure fluorine based excimer laser gas mixtures

    OpenAIRE

    Mathew, D

    2007-01-01

    Fluorine based excimer lasers such as KrF, ArF and F2 are currently the most powerful sources available in the ultraviolet wavelength range, operating at 248 nm, at 193 nm and at 157 nm, respectively. They are thus of central importance for numerous applications in this range. At these short wavelengths, reaching the laser threshold for an efficient operation, F2-based lasers require to be pumped, in a controlled manner, with very high power densities. This can practically be achieved only vi...

  19. Excimer Laser Phototherapeutic Keratectomy for the Treatment of Clinically Presumed Fungal Keratitis

    OpenAIRE

    Liang-Mao Li; Li-Quan Zhao; Ling-Hui Qu; Peng Li

    2014-01-01

    This retrospective study was to evaluate treatment outcomes of excimer laser phototherapeutic keratectomy (PTK) for clinically presumed fungal keratitis. Forty-seven eyes of 47 consecutive patients underwent manual superficial debridement and PTK. All corneal lesions were located in the anterior stroma and were resistant to medication therapy for at least one week. Data were collected by a retrospective chart review with at least six months of follow-up data available. After PTK, infected cor...

  20. Electron microscopic and immunohistochemical examination of scarred human cornea re-treated by excimer laser.

    Science.gov (United States)

    Bleckmann, Heinrich; Schnoy, Norbert; Kresse, Hans

    2002-04-01

    To elucidate differences, at the macromolecular level, in corneal tissue subjected to repeated argon fluoride excimer treatment. A light microscopic, electron microscopic, and immunohistochemical study was performed on a scarred human cornea. Keratocytes were enlarged with an expanded endoplasmic reticulum and exhibited a fibroblastic appearance. Amorphous material was observed extracellularly. Collagen fibrils exhibited a disordered arrangement while banding patterns and diameter were normal. Immunohistochemical investigation of several collagen types, of collagen-associated proteoglycans, and of basement membrane components demonstrated an enhanced immunoreactivity of all of them in the scarred area. Type V collagen was found as a normal component of the epithelial basement membrane whereas types I and III collagen were present beneath Bowman's layer. Excimer-laser-treated sections revealed considerably stronger subepithelial staining for collagen types I, III, IV, and V. Laminin-1, a typical component of basement membranes, was detectable throughout the scarred tissue. The small proteoglycans decorin and fibromodulin accumulated in a patch-like manner in the scarred tissue below the epithelium, whereas biglycan was expressed by the epithelium and throughout the stroma. Lumican was expressed most strongly by the epithelium and rather equally distributed in the excimer-laser-treated and in the normal stroma. Effects of argon laser treatment of the cornea must be regarded as a process acting over many months. Intra- and extracellular structures and components are involved and influence the unpredictable shape of the corneal architecture.

  1. Comparison of KrF and ArF excimer laser treatment of biopolymer surface

    Energy Technology Data Exchange (ETDEWEB)

    Michaljaničová, I. [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic); Slepička, P., E-mail: petr.slepicka@vscht.cz [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic); Heitz, J.; Barb, R.A. [Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria); Sajdl, P. [Department of Power Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic); Švorčík, V. [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic)

    2015-06-01

    Highlights: • The influence of ArF and KrF laser on biopolymer surface was determined. • ArF laser acts predominantly on biopolymer surface. • PHB roughness is increased similarly for both applied wavelengths. • Roughness of nanostructures can be precisely controlled. • ArF laser introduces nitrogen on PHB surface. - Abstract: The goal of this work was the investigation of the impact of two different excimer lasers on two biocompatible and biodegradable polymers (poly-L-lactide and poly hydroxybutyrate). Both polymers find usage in medical and pharmaceutical fields. The polymers were modified by KrF and ArF excimer lasers. Subsequently the impact on surface morphology, surface chemistry changes, and thermal properties was studied by means of confocal and AFM microscopy, FTIR and XPS spectroscopy and DSC calorimetry. Under the same conditions of laser treatment it was observed that ArF laser causes more significant changes on surface chemistry, surface morphology and pattern formation on the polymers under investigation. The data obtained in this work can be used for a wide range of possible applications, in tissue engineering or in combination with metallization in electronics, e.g. for biosensors.

  2. Surface ablation of PLLA induced by KrF excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Slepička, P., E-mail: petr.slepicka@vscht.cz [Department of Solid State Engineering, Institute of Chemical Technology Prague, 166 28 Prague (Czech Republic); Michaljaničová, I. [Department of Solid State Engineering, Institute of Chemical Technology Prague, 166 28 Prague (Czech Republic); Sajdl, P. [Department of Power Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Fitl, P. [Department of Physics and Measurements, Faculty of Chemical Engineering, Institute of Chemical Technology Prague, 166 28 Prague (Czech Republic); Švorčík, V. [Department of Solid State Engineering, Institute of Chemical Technology Prague, 166 28 Prague (Czech Republic)

    2013-10-15

    The surface characterization of PLLA (poly-L-lactic-acid) and its ablation due to excimer laser treatment is introduced in this paper. The main focus is to determine surface wettability and morphology changes in combination with changes of surface chemistry. The ablation loss and the determination of ablation threshold were used to study the biopolymer stability when treated to different laser fluences and pulse counts. The surface polarity was estimated using goniometry. AFM (atomic force microscopy) was used to determine the polymer surface morphology and roughness. The excimer laser has a strong effect on the polymer ablation. The thickness loss is strongly dependent on the laser fluence and number of pulses. For the fluences up to 30 mJ cm{sup −2} and 6000 pulses achieved ablation about 5 μm. The glass transition temperature and melting point were determined for the pristine and laser treated films. The increasing pulsed laser fluence leads to the major changes in roughness and morphology. The surface chemistry depends strongly on number of laser pulses.

  3. [Retinal detachment after Excimer laser (myopic LASIK or PRK). A retrospective multicentric study: 15 cases].

    Science.gov (United States)

    Feki, J; Trigui, A; Chaabouni, M; Ben Salah, S; Bouacida, B; Chechia, N; Zayani, A; Nouira, F; Daghfous, F; Ayed, S; Kamoun, M

    2005-05-01

    Refractive surgery by LASIK or photorefractive keratectomy (PRK) generaly aims at a myopic population that has a high probability of developing rhegmatogenous retinal detachment (RD). The authors report a multicenter study with 15 cases of RD appearing after refractive surgery by Excimer laser and discuss the role played by the techniques used. Five centers fitted with nine Excimer laser devices took part in this study. Of 22,700 eyes undergoing refractive myopic surgery during the period 1994-2002, 15 eyes developed rhegmatogenous RD. The average age of the patients with RD was 37 years. The average myopia was 13.5 D. RD occurred a mean of 20 months after refractive laser. Fifteen eyes of 13 patients developed a rhegmatogenous RD, two of which were bilateral. Eight of these cases had LASIK surgery and six had photorefractive keratectomy; one of the latter patients was retreated with LASIK because of substantial regression after PRK. RD was total or subtotal in five eyes, partial superior with a temporal tear in six eyes, and nasal in three eyes. One case with inferior RD, two cases with giant retinal tear and one case with posterior tear were also repaired. Fourteen eyes were suitable for operation. The retina was reattached in 12 cases. Mean postoperative visual acuity was 7/10. The occurrence of rhegmatogenous RD in the myopic population is estimated at 2.2%. It is estimated at 0.1% in the emmetropic population. The Excimer laser, through its thermic effects, shock wave, traumatism undergone by the suction ring at the time of LASIK surgery, could increase this risk in myopic patients. A review of the literature cast doubt on the cause and effect hypothesis. Personal and multicenter studies (including ours) show that the frequency rate of rhegmatogenous RD after Excimer laser is equivalent and even lower than that estimated with an emmetropic population. The low percentage of RD after Excimer surgery found in the literature as well as in our study (surgery, the

  4. Fabrication of SERS Active Surface on Polyimide Sample by Excimer Laser Irradiation

    Directory of Open Access Journals (Sweden)

    T. Csizmadia

    2014-01-01

    Full Text Available A possible application of excimer laser irradiation for the preparation of surface enhanced Raman spectroscopy (SERS substrate is demonstrated. A polyimide foil of 125 μm thickness was irradiated by 240 pulses of focused ArF excimer laser beam (λ = 193 nm, FWHM = 20 ns. The applied fluence was varied between 40 and 80 mJ/cm2. After laser processing, the sample was coated with 40 nm silver by PLD in order to create a conducting layer required for the SERS application. The SERS activity of the samples was tested by Raman microscopy. The Raman spectra of Rhodamine 6G aqueous solution (c=10−3 mol/dm3 were collected from the patterned and metalized areas. For areas prepared at 40–60 mJ/cm2 laser fluences, the measured Raman intensities have shown a linear dependence on the applied laser fluence, while above 60 mJ/cm2 saturation was observed. The morphology of the SERS active surface areas was investigated by scanning electron microscopy. Finite element modeling was performed in order to simulate the laser-absorption induced heating of the polyimide foil. The simulation resulted in the temporal and spatial distribution of the estimated temperature in the irradiated polyimide sample, which are important for understanding the structure formation process.

  5. The development and progress of XeCl Excimer laser system

    Science.gov (United States)

    Zhang, Yongsheng; Ma, Lianying; Wang, Dahui; Zhao, Xueqing; Zhu, Yongxiang; Hu, Yun; Qian, Hang; Shao, Bibo; Yi, Aiping; Liu, Jingru

    2015-05-01

    A large angularly multiplexed XeCl Excimer laser system is under development at the Northwest Institute of Nuclear Technology (NINT). It is designed to explore the technical issues of uniform and controllable target illumination. Short wavelength, uniform and controllable target illumination is the fundamental requirement of high energy density physics research using large laser facility. With broadband, extended light source and multi-beam overlapping techniques, rare gas halide Excimer laser facility will provide uniform target illumination theoretically. Angular multiplexing and image relay techniques are briefly reviewed and some of the limitations are examined to put it more practical. The system consists of a commercial oscillator front end, three gas discharge amplifiers, two electron beam pumped amplifiers and the optics required to relay, encode and decode the laser beam. An 18 lens array targeting optics direct and focus the laser in the vacuum target chamber. The system is operational and currently undergoing tests. The total 18 beams output energy is more than 100J and the pulse width is 7ns (FWHM), the intensities on the target will exceed 1013W/cm2. The aberration of off-axis imaging optics at main amplifier should be minimized to improve the final image quality at the target. Automatic computer controlled alignment of the whole system is vital to efficiency and stability of the laser system, an array of automatic alignment model is under test and will be incorporated in the system soon.

  6. Green synthesis of selenium nanoparticles by excimer pulsed laser ablation in water

    Directory of Open Access Journals (Sweden)

    O. Van Overschelde

    2013-10-01

    Full Text Available Pure selenium nanoparticles were successfully synthesized by Liquid Phase - Pulsed Laser Ablation (LP-PLA in de-ionized water. Excimer laser (248 nm operating at low fluence (F ∼ 1 J/cm2 was used to generate colloidal solutions of selenium nanoparticles. The obtained selenium nanoparticles were characterized by UV-visible spectroscopy, Raman spectroscopy, Dynamic Light Scattering, and Transmission Electron Microscopy. We describe the multi-modal size distributions generated and use the centrifugation method to isolate the smallest nanoparticles (∼60 nm in diameter.

  7. Effects of excimer laser annealing on low-temperature solution based indium-zinc-oxide thin film transistor fabrication

    OpenAIRE

    Chen,Chao-Nan; Huang, Jung-Jie

    2015-01-01

    A Solution Based Indium-Zinc-Oxide thin-film transistor (TFT) with a field-effect mobility of 0.58 cm2/Vs, a threshold voltage of 2.84 V by using pulse laser annealing processes. Indium-zinc-oxide (IZO) films with a low process temperature were deposited by sol-gel solution based method and KrF excimer laser annealing (wavelength of 248 nm). Solution based indium-zinc-oxide (IZO) films usually needs high temperature about 500 °C post annealing in a oven. KrF excimer laser annealing shows adva...

  8. XeCl excimer laser with new prism resonator configurations and its performance characteristics.

    Science.gov (United States)

    Benerji, N S; Singh, A; Varshnay, N; Singh, Bijendra

    2015-07-01

    New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configuration with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.

  9. XeCl excimer laser with new prism resonator configurations and its performance characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Benerji, N. S., E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in; Singh, A.; Varshnay, N.; Singh, Bijendra, E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in [Excimer Laser Section, LMPD, Raja Ramanna Center for Advanced Technology, Indore 452013 (India)

    2015-07-15

    New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configuration with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.

  10. Reconsidering Sequential Double Running Suture Removal After Penetrating Keratoplasty: A Prospective Randomized Study Comparing Excimer Laser and Motor Trephination.

    Science.gov (United States)

    Seitz, Berthold; Hager, Tobias; Langenbucher, Achim; Naumann, Gottfried O H

    2017-12-14

    We assessed the impact of sequential double running suture removal on corneal curvature after penetrating keratoplasty (PK), comparing mechanical and nonmechanical excimer laser trephination. PK was performed in 134 patients (mean age 51 ± 18 yrs) using either the excimer laser [excimer, n = 60 (37 keratoconus and 23 Fuchs dystrophy)] or motor trephination [control, n = 74 (44 keratoconus and 30 Fuchs dystrophy)] and a double running cross-stitch suture. Refractometry, Zeiss keratometry, and Tomey corneal topography were performed before removal of the first suture (15.2 ± 4.2 mo) and immediately before and at least 6 weeks after removal of the second suture (21.4 ± 5.6 mo). Keratometry before removal of the first (-1.7 ± 2.3 D vs. -3.1 ± 2.8 D) and second (-2.3 ± 2.6 D vs. -3.8 ± 2.8 D) sutures showed that the change in the corneal base curve was significantly smaller in the excimer group than the control group (P control groups, respectively, resulting in significantly lower astigmatism in the excimer (3.1 ± 2.1 D) group compared with the control group (6.2 ± 2.9 D) with "all-sutures-out" (P vector-corrected astigmatism (Jaffe) was significantly smaller in the excimer group (4.3 ± 3.5 D) than in the control group (6.9 ± 4.5 D; P motor trephination.

  11. Plume emission, shock wave and surface wave formation during excimer laser ablation of the cornea.

    Science.gov (United States)

    Bor, Z; Hopp, B; Rácz, B; Szabó, G; Ratkay, I; Süveges, I; Füst, A; Mohay, J

    1993-01-01

    Excimer lasers are now used for corneal surgery; however, the physical processes occurring during photoablation of the cornea are incompletely understood. High speed laser-based photographic arrangement was constructed. The temporal resolution was better than 1 ns. The setup could work as a Schlieren arrangement, which is sensitive to the refractive index change caused by the shock wave propagating in the air above the eye. With minor changes the setup was converted into a shadowgraph, which could detect the ablation plume and the waves propagating on the surface of the eye. Due to the impact of the excimer laser pulse onto the surface of the cornea, a shock wave was generated in the air. The shadowgraph clearly showed the ejection of the ablated cornea. The ejection velocity of the plume was found to be over 600 m/s. It was shown for the first time that the recoil forces of the plume are generating a wave on the surface of the eye. The laser-based high speed photographic arrangement is a powerful arrangement in the study of physical effects occurring during photoablation of the cornea.

  12. Changes in gene expression by 193- and 248-nm excimer laser radiation in cultured human fibroblasts.

    Science.gov (United States)

    Rimoldi, D; Flessate, D M; Samid, D

    1992-09-01

    Tissue ablation by ultraviolet excimer lasers results in exposure of viable cells to subablative doses of radiation. To understand the potential biological consequences better, we have studied changes in gene expression in cultured human skin fibroblasts exposed to either 193- or 248-nm laser light. Northern blot analyses revealed that both treatments up-regulate a common set of genes, including interstitial collagenase, tissue inhibitor of metalloprotease, metallothionein, and the proto-oncogene c-fos. Dose-response and kinetic studies of collagenase induction by 193-nm radiation showed a maximal effect with 60 J/m2 and at approximately 24 h. The induction was still persistent 96 h later. In addition to the commonly affected genes, known to be activated also by conventional UV light (254 nm) and tumor-promoting phorbol esters, other genes were found to be selectively induced by the 193-nm radiation. The heat-shock hsp70 mRNA, undetectable in controls and in cultures irradiated at 248 nm, was transiently induced 8 h after exposure to 193-nm radiation. Furthermore, a selective up-regulation of collagen type I expression was observed. The results indicate that the 193- and 248-nm radiations by excimer lasers elicit specific and different cellular responses, in addition to an overlapping pathway of gene activation common also to UV radiation by germicidal lamps. The laser-induced genes could serve as molecular markers in evaluating cell injury in situ.

  13. Investigation of the effects of LIFT printing with a KrF-excimer laser on thermally sensitive electrically conductive adhesives

    NARCIS (Netherlands)

    Perinchery, S.M.; Smits, E.C.P.; Sridhar, A.; Albert, P.; Brand, J. van den; Mandamparambil, R.; Yakimets, I.; Schoo, H.F.M.

    2014-01-01

    Laser induced forward transfer is an emerging material deposition technology. We investigated the feasibility of this technique for printing thermally sensitive, electrically conductive adhesives with and without using an intermediate dynamic release layer. A 248nm KrF-excimer laser was used to

  14. Excimer laser patterning of PEDOT-PSS thin-films on flexible barrier foils: a surface analysis study

    NARCIS (Netherlands)

    Naithani, S.; Schaubroeck, D.; Vercammen, Y.; Mandamparambil, R.; Yakimets, I.; Vaeck, L. van; Steenberge, G. van

    2013-01-01

    Selective laser patterning of thin organic films is an important aspect in the roll-to-roll production of organic electronic devices such as organic light emitting diodes (OLEDs). An excimer laser is well suited for the patterning and structuring of polymer thin films as their UV absorption is

  15. Coloring linens with excimer lasers to simulate the body image of the Turin Shroud

    Science.gov (United States)

    Baldacchini, Giuseppe; di Lazzaro, Paolo; Murra, Daniele; Fanti, Giulio

    2008-03-01

    The body image of the Turin Shroud has not yet been explained by traditional science; so a great interest in a possible mechanism of image formation still exists. We present preliminary results of excimer laser irradiation (wavelength of 308 nm) of a raw linen fabric and of a linen cloth. The permanent coloration of both linens is a threshold effect of the laser beam intensity, and it can be achieved only in a narrow range of irradiation parameters, which are strongly dependent on the pulse width and time sequence of laser shots. We also obtained the first direct evidence of latent images impressed on linen that appear in a relatively long period (one year) after laser irradiation that at first did not generate a clear image. The results are compared with the characteristics of the Turin Shroud, reflecting the possibility that a burst of directional ultraviolet radiation may have played a role in the formation of the Shroud image.

  16. Excimer laser micromachining of oblique microchannels on thin ...

    Indian Academy of Sciences (India)

    The edge roughness of the channels, machined with a square laser spot of side 100lm, is found to be most affected by the fluence–spot overlap interaction, and the channel width by spot-overlap and the angle of tilt of the traversed path. Polymer coated metal films underwent close to ideal machining, aided by the clamping ...

  17. Effect of open ultraviolet germicidal irradiation lamps on functionality of excimer lasers used in cornea surgery.

    Science.gov (United States)

    Belovickis, Jaroslavas; Kurylenka, Aliaksei; Murashko, Vadim

    2017-01-01

    We report on the impact of direct ultraviolet germicidal irradiation (UVGI) on reflective optics, used in the excimer laser system Allegretto Eye-Q. The aim of our work was to confirm our hypothesis based on long-rate observations of obtained anomalies in post-operative results that are attributed to degradation of reflective optics upon ultraviolet radiation. The presence of direct UVGI coupled with humidity in the operating environment caused merging anomalies and unwanted post-operative correction values. Ultraviolet-A radiation caused a similar effect on the reflective cover of the mirrors.

  18. Preliminary results of VISX excimer laser myopic photorefractive keratectomy at Cedars-Sinai Medical Center

    Science.gov (United States)

    Maguen, Ezra I.; Berlin, Michael S.; Hofbauer, John; Macy, Jonathan I.; Nesburn, Anthony B.; Papaioannou, Thanassis; Salz, James J.

    1992-08-01

    Sixty-two eyes underwent excimer laser photorefractive keratectomy (PRK) for the correction of myopia at Cedars-Sinai-Medical-Center. The first group of 12 patients are presented with follow up data of ten months postoperatively. The second group of 50 patients are presented with follow up data of three months postoperatively. An in-depth comparison of pre and postoperative refractive data is presented. Comparisons between pre and postoperative corrected and uncorrected Snellen visual acuities are provided in order to asses the functional visual result of the procedure.

  19. Generation of large-area microscale manifolds using excimer laser ablation

    Science.gov (United States)

    Zhou, Simon; Kilgo, Marvin M., III; Williams, Charles N.

    1999-08-01

    Excimer laser ablation of polymeric materials is a widely used technology for the generation of nozzles and through- holes. Ablation is also a viable process to create more complex fluidic structures such as channels and manifolds. This paper presents recent results of experiments demonstrating the creation of manifolds in 25 micrometers polyimide films. These structures include cross-over points, and channels of various widths. The results presented include photomicrographs and SEMS, and characterization of channel wall taper and width control as well as an assessment of ablation depth uniformity over large fields. The characteristics of projection ablation systems are reviewed, and the experimental system is described in detail.

  20. Important technological problems with stable operation of electron beam pumped KrF excimer laser amplifier

    CERN Document Server

    Ma Wei Yi; Hu Feng Ming; Shan Yu Sheng; Wang Nai Yan

    2002-01-01

    Some important technological problems with stable operation of the two-side electron beam pumped main amplifier used in the 'Heaven-1' high power KrF excimer laser system are described. They are the problems of the electric breakdown of the insulator support for water dielectric transmission lines, anode foil installation of large area electron beam diode, shape of Hibachi ribs that contact the pressure foil, and formation of diode post pulses and their damage to the anode foil and cathode emitter. Emphasis is put on the effect of different main-switch breakdown times on diode post pulses and the determination of the optimal breakdown time

  1. Excimer laser reactive deposition of vanadium nitride thin films

    Science.gov (United States)

    D'Anna, E.; Di Cristoforo, A.; Fernández, M.; Leggieri, G.; Luches, A.; Majni, G.; Mengucci, P.; Nanai, L.

    2002-01-01

    We report on the deposition of thin vanadium nitride films by ablating vanadium targets in low-pressure N 2 atmosphere, and on their characterization. The targets were vanadium foils (purity 99.8%). 3 in. Si(1 1 1) wafers were used as substrates. Film characteristics (composition and crystalline structure) were studied as a function of N 2 pressure (0.5-200 Pa), KrF laser fluence (4.5-19 J/cm 2), substrate temperature (20-750 °C) and target-to-substrate distance (30-70 mm). Vanadium nitride is already formed at low N 2 ambient pressures (1 Pa) and laser fluences (6 J/cm 2) on substrates at room temperature. At the N 2 pressures of 1-10 Pa, the prevalent phase is VN. At higher pressures (100 Pa) and at relatively high laser fluences (16-19 J/cm 2), the dominant phase is V 2N. The crystallinity of the films improves by increasing the substrate temperature. Well-crystallized films are obtained on substrates heated at 500 °C.

  2. New excimer laser technique for the correction of strabismus and diplopia

    Science.gov (United States)

    Azar, Dimitri T.

    1994-06-01

    We used the ArF excimer laser to determine the feasibility of performing prismatic photoablations in model eyes (plastic spheres simulating the eye), and in rabbit corneas. This would correct diplopia and small angles of deviation, and result in minimal refractive alterations. We modified excimer laser delivery system that achieved the desired corneal contour of prismatic ablations. 193-nm argon fluoride laser was used at fluence of 160 mJ/cm2 and ablation rate 5 Hz. 5.0-mm diameter, 40 um corneal epithelial ablation were followed by 5.0- mm diameter, prismatic photokeratectomy (PPK). We were able to achieve prismatic photoablation of PMMA blocks and lenses. No other refractive changes accompanied the prismatic photoablation of PMMA blocks and lenses. No other refractive changes accompanied the prismatic effect. In rabbits re-epithelialization of the 5-mm ablations was complete by day 3, and corneal haze was not observed by gross examination. Epithelial hyperplasia and subepithelial scarring were noted at the deep edges. PPK holds important therapeutic potential for fine-tuning results of conventional strabismus surgery, and for patients with stable diplopia following nerve palsy and ocular surgery.

  3. Photo-triggering and secondary electron produced ionization in electric discharge ArF* excimer lasers

    Science.gov (United States)

    Xiong, Zhongmin; Kushner, Mark J.

    2011-10-01

    Electric discharge excimer lasers are sustained in multi-atmosphere attaching gas mixtures that are typically preionized to enable a reproducible, uniform glow, which maximizes optical quality and gain. This preionization is often accomplished using UV light produced by a corona discharge within the plasma cavity. To quantify the relationship between corona discharge properties and those of the laser discharge, the triggering of electron avalanche by preionizing UV light in an electric discharge-pumped ArF* excimer laser was numerically investigated using a two-dimensional model. The preionizing UV fluxes were generated by a corona-bar discharge driven by the same voltage pulse as the main discharge sustained in a multi-atmospheric Ne/Ar/Xe/F2 gas mixture. The resulting peak photo-electron density in the inter-electrode spacing is around 108 cm-3, and its distribution is biased toward the UV source. The preionization density increases with increasing dielectric constant and capacitance of the corona bar. The symmetry and uniformity of the discharge are, however, improved significantly once the main avalanche develops. In addition to bulk electron impact ionization, the ionization generated by sheath accelerated secondary electrons was found to be important in sustaining the discharge current at experimentally observed values. At peak current, the magnitude of the ionization by sheath accelerated electrons is comparable to that from bulk electron impact in the vicinity of the cathode.

  4. Colouring fabrics with excimer lasers to simulate encoded images: the case of the Shroud of Turin

    Science.gov (United States)

    Di Lazzaro, P.; Baldacchini, G.; Fanti, G.; Murra, D.; Santoni, A.

    2008-10-01

    The faint body image embedded into the Turin Shroud has not yet explained by traditional science. We present experimental results of excimer laser irradiation (wavelengths 308 nm and 193 nm) of a raw linen fabric and of a linen cloth, seeking for a possible mechanism of image formation. The permanent coloration of both linens is a threshold effect on the laser beam intensity and it can be achieved only in a surprisingly narrow range of irradiation parameters: the shorter the wavelength, the narrower the range. We also obtained the first direct evidence of latent images impressed on linen that appear in a relatively long period (one year) after a laser irradiation that at first did not generate a clear image. The results are compared to the characteristics of the Turin Shroud, commenting the possibility that a burst of directional ultraviolet radiation may have played a role in the formation of the Shroud image.

  5. Applicability of KrF excimer laser induced fluorescence in sooting high-pressure flames

    Energy Technology Data Exchange (ETDEWEB)

    Hildenbrandt, F.; Schulz, C.; Sick, V.; Jander, H.; Wagner, H.G.

    1999-07-01

    Laser-induced emissions obtained after excitation with a tunable KrF excimer laser at 248 nm were measured in well-defined sooting laminar high-pressure flames fueled with methane/air and ethylene/air up to 15 bar. A spectral analysis shows that Mie scattering, Raman scattering and laser-induced fluorescence (LIF) signals can be used for detailed flame studies under sooting high-pressure conditions. Mie scattering is correlated with soot, Raman signals can be used to measure spatially-resolved major species concentrations as well as temperatures. A LIF-scheme to measure NO was found to be applicable even under these conditions. The broadband fluorescence in the range from 270 to 290 nm, usually discarded as background, correlates well with the total concentration of polycyclic aromatic hydrocarbons (PAH) as measured via GC-MS methods. (orig.)

  6. Processing of bioglass coatings by excimer laser ablation

    Energy Technology Data Exchange (ETDEWEB)

    Serra, J.; Gonzalez, P.; Chiussi, S.; Leon, B.; Perez-Amor, M. [Vigo Univ. (Spain). Dept. de Fisica Aplicada

    2001-07-01

    Bioglass (BG) coatings have been prepared in different N{sub 2}O atmospheres by pulsed laser deposition (PLD) using a BG target and an ArF laser. Changes in composition and refractive index were observed by Fourier transform infrared spectroscopy (FTIR), energy dispersive spectroscopy (EDS) and single-wavelength ellipsometry. Film thicknesses were measured by profilometry and surface morphology was observed by scanning electron microscopy (SEM). It has been shown that target composition is transferred to the substrate and that films properties can be modified using different N{sub 2}O atmospheres during the growth process. We observed also a gradual variation of the film refractive index with increasing N{sub 2}O pressures and FTIR spectra reveal that the formation of non-bridging oxygen bonds in the coatings can be controlled. It is well-known, that these bond units determine the formation of apatite on the surfaces of bioactive glass coatings (BGCs) after being soaked in simulated body fluid (SBF), which is an essential characteristic of biocompatibility. (orig.)

  7. Regression and wound healing after excimer laser PRK: a histopathological study on human corneas.

    Science.gov (United States)

    Lohmann, C P; Patmore, A; O'Brart, D; Reischl, U; Winkler Mohrenfels, C; Marshall, J

    1997-01-01

    The results of excimer laser PRK are promising as more than 80% of eyes with up to -6.0 diopters of attempted correction have refractive results within 1.0 diopter of emmetropia. However, throughout the dioptric range some unexpected results have been observed with individual patients showing an aggressive wound healing response with excessive myopic regression and severe corneal haze. Unfortunately, only limited data are available about the cellular and extracellular responses in human corneas after PRK and this information is important to establish adequate postoperative pharmaceutical treatment. We made a histopathological and immunohistochemical study on 20 human corneal samples from patients with severe corneal haze and myopic regression. The indirect immunofluorescence method was used for demonstration of collagen types I, III, IV laminin, chondroitin sulphate, dermatan sulphate, and keratin. All corneal specimens showed a hyperplastic epithelium. Histologically, most samples (16/20) showed mainly a loose lamination of extracellular material which could be identified as collagen type IV. The remaining four samples had newly synthesised collagen type III. Our histopathological results indicate that corneal wound healing after excimer laser PRK varies among individuals. In some people epithelial basement proteins, such as collagen type IV, are the main wound healing products, whereas in others mainly collagen type III is found postoperatively, which does not effect the synthesis of collagen type IV. This suggests the need for individually-tailored postoperative pharmaceutical treatment regimens.

  8. Immunofluorescence study of corneal wound healing after excimer laser anterior keratectomy in the monkey eye.

    Science.gov (United States)

    Malley, D S; Steinert, R F; Puliafito, C A; Dobi, E T

    1990-09-01

    We performed anterior keratectomies on six monkey eyes, four by excimer laser large-area ablation at 193 nm and two by mechanical keratectomy. Immunofluorescence was used to study the wound healing response histopathologically. The distribution of fibrinogen, fibronectin, laminin, collagen types III, IV, and VI, and keratan sulfate was determined at postoperative intervals of 24 hours, 6 days, and 1 month. At 24 hours, fibrinogen and fibronectin coated the ablated surface, but corneal epithelial cells had not yet migrated over the wound. By 6 days and persisting at 1 month, an epithelial ingrowth of seven to 10 layers, mild stromal hypercellularity, and new collagen formation were present in the repair region. At 1 month, fibrinogen, fibronectin, laminin, and type III collagen were strongly detected in the repair region. Type VI collagen was present in both normal and healed corneal stroma at all intervals, and type IV collagen was present in Descemet's membrane only. Sulfated keratan sulfate was absent from the newly synthesized collagen stroma at all intervals. Slit-lamp photographs demonstrated corneal haze in the ablation zone in all cases at 24 hours, persisting for 1 month. The fluorescence patterns produced by excimer laser ablation and mechanical keratectomy were qualitatively identical.

  9. A new transepithelial phototherapeutic keratectomy mode using the NIDEK CXIII excimer laser.

    Science.gov (United States)

    Buzzonetti, Luca; Petrocelli, Gianni; Laborante, Antonio; Mazzilli, Emilio; Gaspari, Mario; Valente, Paola; Francia, Elisa

    2009-01-01

    To evaluate epithelial healing, postoperative pain, and best spectacle-corrected visual acuity (BSCVA) after transepithelial photorefractive keratectomy (PRK) performed with a new phototherapeutic keratectomy (PTK) mode using the NIDEK CXIII excimer laser. Fifteen eyes from 10 patients with myopia underwent transepithelial PRK using a multistage program to perform PTK followed by PRK. The PTK incorporated Flex Scan, which accounts for the loss of radial ablation efficiency on the peripheral cornea. The epithelium was removed with the excimer laser by monitoring the disappearance of blue fluorescence during the ablation. Epithelial healing was evaluated by taking slit-lamp photographs every 24 hours until complete reepithelialization. Postoperative pain was measured according to the Faces Pain Rating Scale. All outcomes are reported for 3 months postoperatively. Haze was graded by two ophthalmologists, each masked to the other's result. Mean reepithelialization took 3.50+/-0.85 days, mean pain score was 3.00+/-1.20, and BSCVA was 20/20 for 9 eyes, 20/30 for 3 eyes, and 20/40 for 3 eyes. All patients had haze below grade 2. The outcomes of the preliminary study show that the incorporation of the Flex Scan algorithm in the PTK mode is as safe and effective as conventional PTK algorithms. The primary advantage of this new PTK mode may be more consistent epithelial removal. Additional studies are needed to determine long-term outcomes.

  10. Pain after epithelial removal by ethanol-assisted mechanical versus transepithelial excimer laser debridement.

    Science.gov (United States)

    Kanitkar, K D; Camp, J; Humble, H; Shen, D J; Wang, M X

    2000-01-01

    To compare subjective pain responses between two techniques of epithelial removal prior to photorefractive keratectomy (PRK) treatment: ethanol-soaked pledget with mechanical debridement of the epithelium versus excimer laser transepithelial ablation. Nine patients underwent bilateral PRK. Each had the epithelium in one eye debrided by placing a pledget soaked in 20% ethanol on the cornea for 2 minutes followed by gentle scraping with a blade. The epithelium in the other eye was removed by transepithelial phototherapeutic keratectomy (PTK) treatment. For each eye, PRK was initiated immediately after removal of the epithelium. On postoperative day one, each patient was asked to rate the level of pain suffered over the last 24 hours on a scale of 0 (minimal) to 10 (maximal). Data were analyzed in a masked fashion. Postoperative day one average pain level in the ethanol-assisted mechanically debrided eyes was 3.0 +/- 2.5 and in the transepithelial PTK eyes was 6.8 +/- 1.8. The difference was statistically significant by Student's t-test (P < .01). All epithelial defects healed within 3 days with no clinically significant difference in healing time between the two techniques. In preparation for PRK, ethanol-assisted mechanical debridement of the epithelium caused significantly less postoperative pain than epithelial removal using the excimer laser.

  11. Validade da topografia de córnea na cirurgia refrativa com excimer laser Validity of corneal topography in refractive surgery with excimer laser

    Directory of Open Access Journals (Sweden)

    Orlando da Silva Filho

    2003-12-01

    Full Text Available OBJETIVO: Avaliar os resultados refracionais e a segurança do procedimento cirúrgico PRK (ceratectomia fotorrefrativa com base na topografia de córnea no pré-operatório. MÉTODOS: Participantes - 44 sujeitos que tinham realizado cirurgia refrativa, com o procedimento ceratectomia fotorrefrativa, os quais apresentaram topografias irregulares pré-operatórias. O grupo controle consistiu de 44 sujeitos com topografia regular pré-operatória. Os 88 olhos foram submetidos a ceratectomia fotorrefrativa utilizando-se o "Summit Apex plus Excimer Laser". As topografias irregulares e regulares foram obtidas pelo "Corneal Analysis System"(EyeSys, sendo consideradas como topografias irregulares os seguintes achados: ápice deslocado acima de 1,5 D (AD, asfericidade maior que 0,25 D/mm (AS, obliquidade maior que 15 graus (OB, assimetria inferior-superior igual ou maior que 1,5 D (IS, curvatura maior que 47 D (CU e combinação de 2 critérios (CB. Principal efeito medido: perda de uma ou mais linhas que foram definidas com segurança para o prognóstico. RESULTADOS: Todos os pacientes foram acompanhados por 6 meses. Verificou-se perda significativa de acuidade visual corrigida em pacientes submetidos ao procedimento PRK-AD (pPURPOSE: To evaluate the refractive results and safety of PRK (photorefractive keratectomy based on the preoperative corneal topography. METHODS: 44 operated eyes, using the photorefractive keratectomy process, and which presented preoperative topographical abnormalities. The control group consisted of 44 eyes with preoperative normal corneal topography. Eighty-eight eyes were submitted to the photorefractive keratectomy process using the Summit Apex plus Excimer Laser. Corneal topographies were accessed by the EyeSys Analysis system; the topographic abnormalities which were considered are the following: apex displacement above 1.5D (AD, asphericity above 0.25D/mm (AS, obliquity above 15 degrees (OB, inferior-superior asymmetry

  12. Excimer laser texturing of natural composite polymer surfaces for studying cell-to-substrate specific response

    Science.gov (United States)

    Dinca, V.; Alloncle, P.; Delaporte, P.; Ion, V.; Rusen, L.; Filipescu, M.; Mustaciosu, C.; Luculescu, C.; Dinescu, M.

    2015-10-01

    Surface modifications of biocompatible materials are among the main factors used for enhancing and promoting specific cellular activities (e.g. spreading, adhesion, migration, and differentiation) for various types of medical applications such as implants, microfluidic devices, or tissue engineering scaffolds. In this work an excimer laser at 193 nm was used to fabricate chitosan-collagen roughness gradients. The roughness gradients were obtained in one step by applying single laser pulses and sample tilting. Fourier transform infrared spectroscopy measurements, atomic force microscopy (AFM), scanning electron microscopy (SEM), and spectro-ellipsometry (SE) were used for sample characterization. The goal is to determine the optimal morpho-chemical characteristics of these structures for in vitro tailoring of protein adsorption and cell behavior. The response induced by the roughness gradient onto various cell lines (i.e. L 929 fibroblasts, HEP G2 hepatocytes, OLN 93 oligodendrocytes, M63 osteoblasts) and bovine serum albumin (BSA) protein absorption was investigated.

  13. Time-resolved spectroscopy and fluorescence resonance energy transfer in the study of excimer laser damage of chromatin

    Energy Technology Data Exchange (ETDEWEB)

    Radu, L. [Department of Molecular Genetics and Radiobiology, Babes National Institute, Bucharest (Romania)], E-mail: lilianajradu@yahoo.fr; Mihailescu, I. [Department of Lasers, Laser, Plasma and Radiation Physics Institute, Bucharest (Romania); Radu, S. [Department of Computer Science, Polytechnics University, Bucharest (Romania); Gazdaru, D. [Department of Biophysics, Bucharest University (Romania)

    2007-09-21

    The analysis of chromatin damage produced by a 248 nm excimer laser radiation, for doses of 0.3-3 MJ/m{sup 2} was carried out by time-resolved spectroscopy and fluorescence resonance energy transfer (FRET). The chromatin was extracted from a normal and a tumoral tissue of Wistar rats. The decrease with laser dose of the relative contribution of the excited state lifetimes of ethidium bromide (EtBr) bounded to chromatin constitutes an evidence of the reduction of chromatin deoxyribonucleic acid (DNA) double-strand structure. FRET was performed from dansyl chloride to acridine orange, both coupled to chromatin. The increase of the average distance between these ligands, under the action of laser radiation, reflects a loosening of the chromatin structure. The radiosensitivity of tumor tissue chromatin is higher than that of a normal tissue. The determination of the chromatin structure modification in an excimer laser field can be of interest in laser therapy.

  14. Evaluation of the efficacy of excimer laser ablation of cross-linked porcine cornea.

    Directory of Open Access Journals (Sweden)

    Shihao Chen

    Full Text Available BACKGROUND: Combination of riboflavin/UVA cross-linking (CXL and excimer laser ablation is a promising therapy for treating corneal ectasia. The cornea is strengthened by cross-linking, while the irregular astigmatism is reduced by laser ablation. This study aims to compare the efficacy of excimer laser ablation on porcine corneas with and without cross-linking. METHODS AND FINDINGS: The porcine cornea was de-epithelialized and treated with 0.1% riboflavin solution for 30 minutes. A half of the cornea was exposed to UVA-radiation for another 30 minutes while the controlled half of the cornea was protected from the UVA using a metal shield. Photo therapeutic keratectomy (PTK was then performed on the central cornea. Corneal thickness of 5 paired locations on the horizontal line, ± 0.5, ± 1.0, ± 1.5, ± 2.0, and ± 2.5 mm from the central spot, were measured using optical coherence tomography prior to and after PTK. The ablation depth was then determined by the corneal thickness. There was a 9% difference (P<0.001 in the overall ablation depth between the CXL-half corneas (158 ± 22 µm and the control-half corneas (174 ± 26 µm. The ablation depths of all 5 correspondent locations on the CXL-half were significantly smaller (P<0.001. CONCLUSION: The efficacy of the laser ablation seems to be lower in cross-linked cornea. Current ablation algorithms may need to be modified for cross-linked corneas.

  15. Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty

    Directory of Open Access Journals (Sweden)

    Achim Langenbucher

    2013-03-01

    Full Text Available Purpose: The purpose of the study was to implement a new eye tracking mask which could be used to guide the laser beam in automated non-mechanical excimer laser assisted penetrating keratoplasty. Materials and methods: A new trephination mask design with an elevated surface geometry has been proposed with a step formation between conical and flat interfaces. Two recipient masks of 7.5/8.0 mm have been manufactured and tested. The masks have outer diameter of 12.5 mm, step formation at 10.5 mm, and slope of conical surfaces 15°. Its functionality has been tested in different lateral positions and tilts on a planar surface, and pig eye experiments. After successful validation on porcine eyes, new masks have been produced and tested on two patients. Results: The build-in eye tracking software of the MEL 70 was always able to capture the masks. It has been shown that the unwanted pigmentation/pattern induced by the laser pulses on the mask surface does not influence the eye-tracking efficiency. The masks could be tracked within the 18 × 14 mm lateral displacement and up to 12° tilt. Two patient cases are demonstrated. No complications were observed during the surgery, although it needs some attention for aligning the mask horizontally before trephination. Stability of eye tracking masks is emphasized by inducing on purpose movements of the patient head. Conclusion: Eye-tracking-guided penetrating keratoplasty was successfully applied in clinical practice, which enables robust tracking criteria within an extended range. It facilitates the automated trephination procedure of excimer laser-assisted penetrating keratoplasty.

  16. Effect of preionization, fluorine concentration, and current density on the discharge uniformity in F2 excimer laser gas mixtures

    NARCIS (Netherlands)

    Mathew, D.; Bastiaens, Hubertus M.J.; Boller, Klaus J.; Peters, P.J.M.

    2007-01-01

    The discharge homogeneity in F2-based excimer laser gas mixtures and its dependence on various key parameters, such as the degree of preionization, preionization delay time, F2 concentration and current density, is investigated in a small x-ray preionized discharge chamber. The spatial and temporal

  17. Evaluation and diffusion of excimer laser treatment of myopia in the United States and in the Netherlands

    NARCIS (Netherlands)

    Vondeling, H.; Rosendal, H.; Banta, D.

    1995-01-01

    Excimer laser photorefractive keratectomy (PRK) is an experimental treatment to correct myopia (short-sightedness) that is diffusing into use without convincing evidence of safety and efficacy. It has been claimed that PRK may render conventional methods of correcting myopia, such as wearing glasses

  18. Fabrication of the Long Bragg Grating by Excimer Laser Micro Machining with High-Precision Positioning XXY Platform

    Directory of Open Access Journals (Sweden)

    Jian-Zhong Wu

    2014-03-01

    Full Text Available With the advancement of technology, the application of fiber Bragg grating is widely used as a Bragg grating sensor. Fiber Bragg grating is fabrication using excimer laser machining with the phase masker. The grating length is decided by the width of laser beam. In this paper, we proposed fabrication of the long Bragg grating by excimer Laser micro machining with a high-precision positioning XXY platform. The high-precision positioning XXY platform plays an important role for long FBG. It needs seriously to combine three short FBGs. Therefore, we can obtain a long FBG with 15mm length. This method can provide a solution to fabricate long FBG by using cheap laser with high-precision positioning XXY platform.

  19. Excimer laser cleaning of encrustation on Pentelic marble: procedure and evaluation of the effects

    Science.gov (United States)

    Maravelaki-Kalaitzaki, P.; Zafiropulos, V.; Fotakis, C.

    1999-06-01

    This work focuses on the use and control of excimer lasers (KrF, λ=248 nm and XeCl, λ=308 nm) for the removal of encrustation (black crusts, soil-dust and biological deposits) from Pentelic marble. A number of surface analytical techniques, such as Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) interfaced with microprobe analysis (energy dispersive X-ray analysis: EDX), X-ray diffraction (XRD), laser-induced breakdown spectroscopy (LIBS) and optical microscopy (OM) were used to detect chemical composition and crust morphology, as well as to monitor the effects induced by the laser treatment. SEM and OM providing structural information about the layers of encrustation, LIBS and SEM-EDX providing information on the elemental composition of the ablated material, XRD and FTIR detecting the changes of minerals appear to be particularly effective in assessing the quality of cleaning process. FTIR and XRD showed removal of pollutants from encrustation and partial transformation of calcium sulfate dihydrate (gypsum) to hemihydrate and anhydrite, which have lower specific surface than gypsum. Irradiation conditions creating minimal damaging effects were defined before treatment through surface analysis, ablation rate studies and optimization of laser parameters. On the basis of structural and analytical examinations, both lasers are shown to be appropriate for achieving sufficient removal of unwanted selected layers without modifying the surface morphology and surpassing by far the effectiveness afforded by traditional cleaning techniques.

  20. Fluorescence imaging inside an internal combustion engine using tunable excimer lasers.

    Science.gov (United States)

    Andresen, P; Meijer, G; Schlüter, H; Voges, H; Koch, A; Hentschel, W; Oppermann, W; Rothe, E

    1990-06-01

    Tunable excimer lasers are used to obtain 2-D images of molecular (and some state-specific) density distributions inside a cylinder of a modified four-cylinder in-line engine that has optical access. Natural fluorescence (i.e., without a laser) is used for some OH pictures, normal laser-induced fluorescence (LIF) for those of NO and of the isooctane fuel, and laser-induced predissociative fluorescence (LIPF) for other OH pictures and for those of O(2). Relevant spectroscopy is done to find the laser and fluorescence frequencies needed to measure isolated species. LIPF works well at high pressures, is state specific, and is ideally suited to follow turbulent processes. No similar measurements in engines have been previously reported. Pictures are taken in succeeding engine cycles. Their sequence is either at a particular point of the engine's cycle to show cyclic fluctuations, or at succeeding portions of the cycle to illustrate the progress of the gasdynamics or of the combustion.

  1. Alternatives to excimer laser refractive surgery: UV and mid-infrared laser ablation of intraocular lenses and porcine cornea

    Science.gov (United States)

    Serafetinides, A. A.; Makropoulou, M.; Spyratou, E.; Bacharis, C.

    2007-03-01

    Despite the fact that the laser applications in human ophthalmology are well established, further research is still required, for better and predictable ablation dosimetry on both cornea tissue and intraocular lenses. Further studies for alternative laser sources to the well established excimer lasers, such as UV or mid-infrared solid state lasers, have been proposed for refractive surgery. The precise lens ablation requires the use of laser wavelengths possessing a small optical penetration depth in the cornea and in the synthetic lenses, in order to confine the laser energy deposition to a small volume. In order to eliminate some very well known problems concerning the reshaping of cornea and the modification of the optical properties of the intraocular lenses, ablation experiments of ex vivo porcine cornea, acrylic PMMA and hydrophilic lenses were conducted with an Er:YAG laser (2.94 μm) and the fifth harmonic of a Nd:YAG laser (213 nm). The morphology of cornea was recorded using a cornea topography system before and immediately after the ablation. Histology analysis of the specimens was obtained, in order to examine the microscopic appearance of the ablated craters and the existence of any thermal damage caused by the mid-infrared and UV laser irradiation. The macroscopic morphology of the intraocular lens craters was inspected with an optical transmission microscope. Measurements of the ablation rates of the lenses were performed and simulated by a mathematical model.

  2. Levels of interleukin-6 in tears before and after excimer laser treatment.

    Science.gov (United States)

    Resan, Mirko; Stanojević, Ivan; Petković, Aleksandra; Pajić, Bojan; Vojvodić, Danilo

    2015-04-01

    Immune response and consequent inflammatory process which originate on ocular surface after a trauma are mediated by cytokines. Photoablation of corneal stroma performed by excimer laser causes surgically induced trauma. Interleukin-6 (IL-6) is mostly known as a proinflammatory cytokine. However, it also has regenerative and anti-inflammatory effects. It is supposed that this cytokine is likely to play a significant role in the process of corneal wound healing response after photoablation of stroma carried out by laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) methods. The aim of this study was to determine and compare the levels of IL-6 in tears before and after treatment with LASIK and PRK methods. The study included 68 shortsighted eyes up to -3.0 diopter sphere, i.e. 198 samples of tears (per three samples taken from each of the eyes), divided into two groups according to the kind of excimer laser intervention performed: the group 1--eyes treated by LASIK method (n=31), and the group 2--eyes treated by the PRK method (n=37). The samples of tears were taken from each eye at the following time points: before excimer laser treatment (0 h, the control group), 1 h after the treatment (1 h) and 24 h after the treatment (24 h). The patients did not use anti-inflammatory therapy 24 h after the intervention. Tear samples were collected using microsurgical sponge. Level of IL-6 in tear fluid was determined by the flow cytometry method, applying a commercial test kit which allowed cytokine detection from a small sample volume. Results. The values of IL-6 were detectable in 16% of samples before LASIK treatment and in 30% of samples before PRK treatment. One h after the treatment IL-6 was detectable in 29% of samples for the LASIK group and 43% of samples for the PRK group, and 24 h after the treatment it was detectable in 19% of samples for the LASIK group and in 57% of samples for the PRK group. When we analyzed the dynamics of IL76 production

  3. Excimer-laser-based multifunctional patterning systems for optoelectronics, MEMS, materials processing, and biotechnology

    Science.gov (United States)

    Jain, Kanti

    2003-07-01

    Over the past few years, there has been an increasing impact of microelectronics fabrication technologies on the realization of structures and spatial patterns necessary for advances in optoelectronics, MEMS, materials processing, and biotechnology. These fabrication technologies accelerate the pace of research by enabling the micro-manipulation and patterning of a variety of organic, inorganic, and biological materials (including new polymers, compound semiconductors, DNA, proteins, and others), developing new synthesis techniques, and producing structures and devices previously not deemed possible. In order to facilitate the exploration of these fields, it is desirable to develop processing techniques and cost-effective, multifunctional systems that can handle a wide variety of substrate materials and geometries, including non-planar surfaces. This paper describes recent advances made in excimer-laser-based patterning, photoablation, and photo-crystallization technologies, focusing on how these technologies address the unique requirements of applications for scientific research and for technology development.

  4. Interaction of 308-nm excimer laser light with temporomandibular joint related structures

    Science.gov (United States)

    Liesenhoff, Tim; Funk, Armin

    1994-02-01

    Arthroscopy of TMJ has become a clinically important and more and more accepted method for diagnosis and treatment of TMJ alteration. This minimal invasive method is clearly limited by the anatomical dimensions of the TMJ. A 308 nm excimer laserlight has already found clinical applications in angioplasty, ophthalmology, and dentistry. The aim of the presented study was to find out if it is possible to ablate TMJ related structures under arthroscopic conditions. It also aims to evaluate the energy-threshold for ablation and the maximal possible rate of ablation. Contrary to other laser systems it offers a unique combination of minimal tissue alteration, precise tissue ablation guidability through optical fibers, and a good transmission through water.

  5. The effect of 193 nm excimer laser radiation on the human corneal endothelial cell density

    Energy Technology Data Exchange (ETDEWEB)

    Isager, P.; Hjortdal, J.Oe.; Ehlers, N. [Aarhus Univ. Hospital, Dept. of Ophthalmology, Aarhus (Denmark)

    1996-06-01

    The effect of 193 nm excimer laser radiation on human corneal endothelial cell density was examined. Fifty-five eyes from 35 patients underwent photorefractive keratectomy for myopia. Photomicrographs of the endothelium were taken a short time before the operation and on an average of 7 months postoperatively with a specular microscope. The average endothelial cell densities were preoperatively 3375 {+-} 266 cells/mm{sup 2} (means {+-} SD) and postoperatively 3348 {+-} 287 cells/mm{sup 2}, corresponding to a fall of 27 cells/mm{sup 2} (N = 55). This fall in endothelial cell density was not statistically significant. A significant correlation between the change in cell density and age of the patient was found, with older patients losing more cells (N = 35, 2p < 0.05). The magnification of the specular microscope was found to change with corneal thickness. The importance of correcting the endothelial cell densities for corneal thickness is discussed. (au) 14 refs.

  6. Pre-operative therapeutic eyelid hygiene in the prevention of complications following excimer laser vision correction

    Directory of Open Access Journals (Sweden)

    V. V. Kurenkov

    2012-01-01

    Full Text Available Purpose: to assess the effectiveness of pre-operative therapeutic eyelid hygiene in the prevention and treatment of dry eye and meibomian glands dysfunction following excimer laser vision surgery.Methods: In enrolled 144 patients (288 eyes, ocular surface and meibomian glands functions were evaluated before and following refractive surgery (LASIK and REIK. In pre- and post-operative period, standard ophthalmological studies were performed, including best-corrected visual acuity determination, biomicroscopy, Schirmer’s test and Norn’s test (tear break-up time. In pre-operative pe- riod, ocular surface microbial profile was assessed. Subjective symptoms of impaired tear production were revealed via questioning. In study group (70 patients, 140 eyes, therapeutic eyelid hygiene using Blefarogel 1 or Blefarogel 2 (Ltd. Heltec-Medica, Moscow, Russia was prescribed one week before surgery. In control group, no therapeutic eyelid hygiene was prescribed. All patients were received antibacterial treatment including Vigamox (Alcon, Fort Worth, tX. In both groups, Natural tears and Systane Ultra (Alcon were used as tear replacement therapy.Results: Complex treatment, including therapeutic eyelid hygiene in study group, significantly improved tear film and ocular sur- face health as well as meibomian glands functions. Inflammatory complications rate was estimated as 5.7% in study group and 10.6% in control group.Conclusion: therapeutic eyelid hygiene is highly effective in the prophylaxis and treatment of post-operative complications duу to ocular surface pathology and meibomian glands dysfunction. the procedure is safe and can be recommended as a part of complex preventive treatment before excimer laser vision correction.

  7. Pre-operative therapeutic eyelid hygiene in the prevention of complications following excimer laser vision correction

    Directory of Open Access Journals (Sweden)

    V. V. Kurenkov

    2014-07-01

    Full Text Available Purpose: to assess the effectiveness of pre-operative therapeutic eyelid hygiene in the prevention and treatment of dry eye and meibomian glands dysfunction following excimer laser vision surgery.Methods: In enrolled 144 patients (288 eyes, ocular surface and meibomian glands functions were evaluated before and following refractive surgery (LASIK and REIK. In pre- and post-operative period, standard ophthalmological studies were performed, including best-corrected visual acuity determination, biomicroscopy, Schirmer’s test and Norn’s test (tear break-up time. In pre-operative pe- riod, ocular surface microbial profile was assessed. Subjective symptoms of impaired tear production were revealed via questioning. In study group (70 patients, 140 eyes, therapeutic eyelid hygiene using Blefarogel 1 or Blefarogel 2 (Ltd. Heltec-Medica, Moscow, Russia was prescribed one week before surgery. In control group, no therapeutic eyelid hygiene was prescribed. All patients were received antibacterial treatment including Vigamox (Alcon, Fort Worth, tX. In both groups, Natural tears and Systane Ultra (Alcon were used as tear replacement therapy.Results: Complex treatment, including therapeutic eyelid hygiene in study group, significantly improved tear film and ocular sur- face health as well as meibomian glands functions. Inflammatory complications rate was estimated as 5.7% in study group and 10.6% in control group.Conclusion: therapeutic eyelid hygiene is highly effective in the prophylaxis and treatment of post-operative complications duу to ocular surface pathology and meibomian glands dysfunction. the procedure is safe and can be recommended as a part of complex preventive treatment before excimer laser vision correction.

  8. THE EXPERIENCE OF TREGALOZA BASED LUBRICANT USAGE FOR PATIENTS WHO UNDERWENT EXCIMER LASER SURGERY

    Directory of Open Access Journals (Sweden)

    E. Eskina

    2016-01-01

    Full Text Available Purpose: to evaluate the tregalose based eye drops effectiveness in patients who underwent PRK or TransPRK surgery. patients and methods: 50 patients with moderate myopia were examined before, 7 days and 1 month after PRK or TransPRK surgery made by SCHWIND Amaris excimer laser by the same surgeon. In addition to conventional diagnostics, Schirmer test and tear break up time were performed as well as ODSI questionare and Oxford index of ocular surface disorders were investigated. Patients were divided in two groups, Study group — “Thealos” group and “Control” group. In both groups patients have started using non preservative eye drops based on tregalosa and hyaluronic acid 4-th day after surgery respectively. results: The tear film breakup time was significantly better in “Thealos” group (7,22±3,61 sec 7 days postop and 9,36±3,68 sec 1 month postop in comparison to «Control” group 5,21±0,25 (р<0,01 sec and 7,21±2,85 sec respectively (р<0,05 as well as ocular surface index score in “Thealos” group post surgery was less (0,26±0,38 и 0,85±0,31 marks 7 days postop (р<0,05 and 0,09±0,19 and 0,21±0,4 (р<0,05 1 month postop respectively. There were no other statistically significant differences found in analysed data. Conclusion: Using of “Thealoz” non-preservative eye drops leads to faster recovery after surface excimer laser ablations in terms of dry eye manifestation, those as tearfilm stability and ocular surface index score, measured using “Oxford” scale. Moistening properties of tregaloze solution could be compared with those of hyaluronic acid solution.

  9. Microstructures induced by excimer laser surface melting of the SiCp/Al metal matrix composite

    Science.gov (United States)

    Qian, D. S.; Zhong, X. L.; Yan, Y. Z.; Hashimoto, T.; Liu, Z.

    2017-08-01

    Laser surface melting (LSM) was carried out on the SiCp/Al metal matrix composite (MMC) using a KrF excimer laser with a fluence of 7 J/cm2. The re-solidification microstructure was characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM) equipped with energy dispersive X-ray detector, and X-ray diffraction (XRD) analysis. It was found that a 2.5 μm thick melted layer was formed in the near-surface region, in which dissolution of the intermetallics and removal of the SiC particles occurred. The thermal and material response upon laser irradiation was simulated using three models, i.e. analytical model, finite element model (FEM) and smoothed-particle hydrodynamics (SPH) model. The effect of SiC particles on the LSM process, the mechanism of the SiC removal and the re-solidification microstructures in the melted layer were discussed. The simulation results were in good agreement with the experimental results and contributed to the generic understanding of the re-solidification microstructures induced by ns-pulsed lasers.

  10. Report on the Study of Radiation Damage in Calcium Fluoride and Magnesium Fluoride Crystals for use in Excimer Laser Applications

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    1999-10-04

    A study was performed to investigate the effects of radiation damage in calcium fluoride and magnesium fluoride crystals caused by gamma rays and UV photons from excimer lasers. The purpose was to study and correlate the damage caused by these two different mechanisms in various types of material used for fabricating optical elements in high power excimer lasers and lens systems of lithography tools. These optical systems are easily damaged by the laser itself, and it is necessary to use only the most radiation resistant materials for certain key elements. It was found that a clear correlation exists between the, radiation induced damage caused by high energy gamma rays and that produced by UV photons from the excimer laser. This correlation allows a simple procedure to be developed to select the most radiation resistant material at the ingot level, which would be later used to fabricate various components of the optical system. This avoids incurring the additional cost of fabricating actual optical elements with material that would later be damaged under prolonged use. The result of this screening procedure can result in a considerable savings in the overall cost of the lens and laser system.

  11. Depth-profile investigations of triterpenoid varnishes by KrF excimer laser ablation and laser-induced breakdown spectroscopy

    Science.gov (United States)

    Theodorakopoulos, C.; Zafiropulos, V.

    2009-07-01

    The ablation properties of aged triterpenoid dammar and mastic films were investigated using a Krypton Fluoride excimer laser (248 nm, 25 ns). Ablation rate variations between surface and bulk layers indicated changes of the ablation mechanisms across the depth profiles of the films. In particular, after removal of the uppermost surface varnish layers there was a reduction of the ablation step in the bulk that was in line with a significant reduction of carbon dimer emission beneath the surface layers as detected by laser-induced breakdown spectroscopy. The results are explicable by the generation of condensation, cross-linking and oxidative gradients across the depth profile of triterpenoid varnish films during the aging degradation process, which were recently quantified and established on the molecular level.

  12. Excimer laser texturing of natural composite polymer surfaces for studying cell-to-substrate specific response

    Energy Technology Data Exchange (ETDEWEB)

    Dinca, V., E-mail: dincavalentina@yahoo.com [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania); Alloncle, P.; Delaporte, P. [Aix-Marseille University, CNRS, LP3 Laboratory, Campus de Luminy, 13288 Marseille (France); Ion, V. [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania); Faculty of Physics, University of Bucharest, 077125 Magurele (Romania); Rusen, L.; Filipescu, M. [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania); Mustaciosu, C. [Horia Hulubei National Institute of Physics and Nuclear Engineering – IFIN HH, Magurele, Bucharest (Romania); Luculescu, C.; Dinescu, M. [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania)

    2015-10-15

    Highlights: • Roughness gradients are obtained in one step by applying single laser pulses and sample tilting. • BSA protein and cell dependence behavior onto gradient characteristics was studied. • The degradation of the samples by lysozyme was correlated to its ability to access the textured area. - Abstract: Surface modifications of biocompatible materials are among the main factors used for enhancing and promoting specific cellular activities (e.g. spreading, adhesion, migration, and differentiation) for various types of medical applications such as implants, microfluidic devices, or tissue engineering scaffolds. In this work an excimer laser at 193 nm was used to fabricate chitosan–collagen roughness gradients. The roughness gradients were obtained in one step by applying single laser pulses and sample tilting. Fourier transform infrared spectroscopy measurements, atomic force microscopy (AFM), scanning electron microscopy (SEM), and spectro-ellipsometry (SE) were used for sample characterization. The goal is to determine the optimal morpho-chemical characteristics of these structures for in vitro tailoring of protein adsorption and cell behavior. The response induced by the roughness gradient onto various cell lines (i.e. L 929 fibroblasts, HEP G2 hepatocytes, OLN 93 oligodendrocytes, M63 osteoblasts) and bovine serum albumin (BSA) protein absorption was investigated.

  13. Film forming properties of silicon nanoparticles on SixNy coated substrates during excimer laser annealing

    Science.gov (United States)

    Caninenberg, M.; Kiesler, D.; Benson, N.; Schmechel, R.

    2017-05-01

    In this article we investigate the film forming properties of excimer laser annealed silicon nanoparticles on non-silicon substrates. In contrast to their film forming properties on oxide free silicon substrates, the nanoparticle thin film tends to dewet and form a porous μ-structure on the silicon nitrite covered glass model substrates considered for our investigation. This is quantified using a SEM study in conjunction with image processing software, in order to evaluate the μ-structure size and inter μ-structure distance in dependence of the laser energy density. To generalize our results, the film forming process is described using a COMSOL Multiphysics ® fluid dynamics model, which solves the Navier Stokes equation for incompressible Newtonian fluids. To account for the porous nanoparticle thin film structure in the simulation, an effective medium approach is used by applying a conservative level set one phase method to our mesh. This effort allows us to predict the Si melt film formation ranging from a porous Si μ-structure to a compact 100% density Si thin film in dependence of the substrate / thin film interaction, as well as the laser energy used for the nanoparticle processing.

  14. The effect on the ultrastructure of dental enamel of excimer-dye, argon-ion and CO2 lasers.

    Science.gov (United States)

    Palamara, J; Phakey, P P; Orams, H J; Rachinger, W A

    1992-12-01

    This study aimed to investigate the ultrastructural changes that occur in dental enamel irradiated with pulsed excimer-dye, continuous-wave (CW) argon-ion and CW CO2 lasers. The pulsed excimer-dye laser produced deep craters, rough damaged surfaces with underlying porosity and amorphous vitrified material. The vitrification of the enamel indicated that the temperature in these areas must have been at least in the range 1280 to 1600 degrees C. The CW argon-ion laser irradiation produced a changed non-cratered surface with inter-crystalline porosity and a mixture of small and some large irregularly packed recrystallized enamel crystals. The CW CO2 laser produced shallow craters, surface crazing and lifting off the removal of the surface layer to expose the underlying roughened enamel. The ultrastructure revealed inter- and intra-crystalline porosity, a mixture of small but variable size irregularly packed recrystallized enamel crystals and also well packed large crystals which indicated further grain growth. The porosity in lased enamel was overall very similar to that seen in enamel heated in an electric furnace to a temperature of 600 degrees C. The presence of recrystallized enamel crystals indicated a temperature rise of approximately 1000 degrees C and the grain growth indicated that a temperature > or = 1000 degrees C existed for some time after the laser irradiation. In general the excimer-dye laser produced most surface destruction because of its higher power density and shorter interaction time and the argon-ion laser produced least damage. These results indicated that the lasers used in this study require much more refinement before they can find therapeutic application to dental enamel, and this may well be the case for other lasers being investigated for clinical dental practise.

  15. Krypton Gas for High Quality Single Wall Carbon Nanotubes Synthesis by KrF Excimer Laser Ablation

    Directory of Open Access Journals (Sweden)

    Jasim Al-Zanganawee

    2015-01-01

    Full Text Available We report for the first time the production of single wall carbon nanotubes (SWCNTs by KrF excimer laser ablation method under the krypton gas atmosphere. For the ablation experiment 450 mJ energy and 30 Hz repetition rate KrF excimer laser was used, and the target was prepared with the following composition: 0.6% Ni, 0.6% Co, and 98.8% C (atomic percentage. The ablation product was characterized by confocal Raman microspectroscopy, transmission electron microscopy (TEM, scanning electron microscopy (SEM, and thermogravimetric analysis (TGA. The SWCNTs obtained are a mixture of semiconducting and metallic types with narrow diameters distribution of 1.26 to 1.49 nm, are micrometers long, and contain low amount of graphite and amorphous carbon.

  16. Des lasers à excimères pour cristalliser le silicium des écrans plats : pourquoi ? comment ?

    Science.gov (United States)

    Prat, C.

    2003-06-01

    Les contraintes techniques et économiques de la fabrication d'écrans plats à cristaux liquides à matrice active ont suscité de nombreuses études de procédés de cristallisation de couches minces de silicium par laser à excimères, exploitant principalement trois types de phénomènes physiques, dans le but d'obtenir des cristaux micrométriques les plus uniformes possible.

  17. Wettability characteristics of carbon steel modified with CO2, Nd:YAG, Excimer and high power diode lasers

    OpenAIRE

    Lawrence, Jonathan; Li, Lin

    2000-01-01

    Interaction of CO2, Nd:YAG, excimer and high power diode laser (HPDL) radiation with the surface of a common mild steel (EN8) was found to effect changes in the wettability characteristics of the steel, namely changes in the measured contact angle. These modifications are related to changes in the surface roughness, changes in the surface oxygen content and changes in the surface energy of the mild steel. The wettability characteristics of the selected mild steel could be controll...

  18. Excimer laser doping technique for application in an integrated CdTe imaging device

    CERN Document Server

    Mochizuki, D; Aoki, T; Tomita, Y; Nihashi, T; Hatanaka, Y

    1999-01-01

    CdTe is an attractive semiconductor material for applications in solid-state high-energy X-ray and gamma-ray imaging systems because of its high absorption coefficient, large band gap, good mobility lifetime product of holes and stability at normal atmospheric conditions. We propose a new concept for fabricating an integrated CdTe with monolithic circuit configuration for two-dimensional imaging systems suitable for medical, research or industrial applications and operation at room temperature. A new doping technique has been recently developed that employs excimer laser radiation to diffuse impurity atoms into the semiconductor. Accordingly, heavily doped n- and p-type layers with resistivities less than 1 OMEGA cm can be formed on the high resistive CdTe crystals. We have further extended this technique for doping with spatial pattern. We will present the laser doping technique and various results thus obtained. Spatially patterned doping is demonstrated and we propose the use of these doping techniques for...

  19. Excimer laser assisted very fast exfoliation and reduction of graphite oxide at room temperature under air ambient for Supercapacitors electrode

    Science.gov (United States)

    Malek Hosseini, S. M. B.; Baizaee, S. M.; Naderi, Hamid Reza; Dare Kordi, Ali

    2018-01-01

    Excimer laser was used for reduction and exfoliation of graphite oxide (GO) at room temperature under air ambient. The prepared excimer laser reduced graphite oxide (XLRGO) is characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), nitrogen adsorption/desorption (BET method), X-ray diffraction (XRD), X-ray photoemission spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR) and UV-vis absorption techniques for surface, structural functional groups and band gap analysis. Electrochemical properties are investigated using cyclic voltammetry, galvanostatic charge-discharge, electrochemical impedance spectroscopy (EIS) and continues cyclic voltammetry (CCV) in 0.5 M Na2SO4 as electrolyte. Electrochemical investigations revealed that XLRGO electrode has enhanced supercapacitive performance including specific capacitance of 299 F/g at a scan rate of 2 mV/s. Furthermore, CCV measurement showed that XLRGO electrode kept 97.8% of its initial capacitance/capacity after 4000 cycles. The obtained results from electrochemical investigations confirm that the reduction of GO by using an excimer laser produces high-quality graphene for supercapacitor applications without the need for additional operations.

  20. Combined Excimer Laser Photoablation and Amniotic Membrane Overlay for Relief of Symptomatic Discomfort in Gelatinous Drop-like Corneal Dystrophy.

    Science.gov (United States)

    Alex, Anne F; Eter, Nicole; Uhlig, Constantin E

    2015-10-01

    To describe the efficacy of combined excimer laser photoablation and amniotic overlay membrane in the relief of symptomatic discomfort in a 17-year-old patient who had gelatinous drop-like corneal dystrophy. The best-corrected visual acuity (BCVA) was measured with Snellen letters. Slit-lamp examination of the ocular surface and anterior chamber was performed at baseline. Results were photodocumented. Excimer laser photoablation was performed and subsequently 2 amniotic membranes were transconjunctivally fixated with 10.0 nylon sutures. Investigations and documentation were performed at baseline, every 2 months in the first year, and then every 6 months. The duration of follow-up was 22 months. At baseline, the BCVA was 20/70 in the right eye and 20/200 in the left eye. The patient reported distinct photophobia. Slit-lamp examination was difficult because of blepharospasm. Although gelatinous drops developed again and the BCVA decreased to 2/200, the patient reported significant relief after both microsurgical treatments and remained comfortable at 20 and 22 months. Excimer laser photocoagulation combined with amniotic membrane overlay does not stop the development of gelatinous drop-like corneal dystrophy but may improve subjective comfort. Such treatment does not hinder subsequent lamellar or penetrating grafts and is helpful in providing the necessary time for preparation of matched keratoplasties.

  1. Microstructures induced by excimer laser surface melting of the SiC{sub p}/Al metal matrix composite

    Energy Technology Data Exchange (ETDEWEB)

    Qian, D.S., E-mail: Daishu.qian@postgrad.manchester.ac.uk; Zhong, X.L.; Yan, Y.Z.; Hashimoto, T.; Liu, Z.

    2017-08-01

    Highlights: • Microstructural analysis of the excimer laser-melted SiC{sub p}/AA2124;. • Analytical, FEM, and SPH simulation of the laser-material interaction;. • Mechanism of the formation of the laser-induced microstructure. - Abstract: Laser surface melting (LSM) was carried out on the SiC{sub p}/Al metal matrix composite (MMC) using a KrF excimer laser with a fluence of 7 J/cm{sup 2}. The re-solidification microstructure was characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM) equipped with energy dispersive X-ray detector, and X-ray diffraction (XRD) analysis. It was found that a 2.5 μm thick melted layer was formed in the near-surface region, in which dissolution of the intermetallics and removal of the SiC particles occurred. The thermal and material response upon laser irradiation was simulated using three models, i.e. analytical model, finite element model (FEM) and smoothed-particle hydrodynamics (SPH) model. The effect of SiC particles on the LSM process, the mechanism of the SiC removal and the re-solidification microstructures in the melted layer were discussed. The simulation results were in good agreement with the experimental results and contributed to the generic understanding of the re-solidification microstructures induced by ns-pulsed lasers.

  2. Influence of corneal collagen crosslinking with riboflavin and ultraviolet-a irradiation on excimer laser surgery.

    Science.gov (United States)

    Kampik, Daniel; Ralla, Bernhard; Keller, Sabine; Hirschberg, Markus; Friedl, Peter; Geerling, Gerd

    2010-08-01

    Riboflavin/ultraviolet A (UVA) cross-linking (CXL) of corneal collagen is a novel method of stabilizing corneal mechanical properties and preventing progression of keratectasias. This study was conducted to investigate whether CXL influences ablation rate, flap thickness, and refractive results of excimer laser procedures ex vivo. Corneal epithelium was removed from enucleated porcine eyes, and CXL was performed with riboflavin 0.1% and UVA radiation (365 nm, 3 mW/cm(2)) for 30 minutes. Control eyes received epithelial abrasion only. Diffusion of riboflavin through the cornea was assessed by using infrared-excited, two-photon microscopy of riboflavin autofluorescence, combined with second-harmonic generation of fibrillar collagen. During phototherapeutic keratectomy, corneal thickness was measured by optical coherence pachymetry. During LASIK for myopia, the flap thickness of microkeratome cuts was measured and the induced refractive change assessed by Placido topography. Data were analyzed by Shapiro-Wilk test and Student's t-test. Multiphoton imaging showed a rapid (30-minute) and even distribution of riboflavin throughout the corneal stroma. No difference in ablation rate was measured in treated and untreated corneas (P = 0.90). Mean flap thickness was increased by 44% in cross-linked corneas (P refractive change was reduced in CXL-treated eyes by 20.1% (P refractive change after LASIK for myopia. Although the laser ablation rate is unaffected, CXL results in an increased flap thickness. This study suggests the need for adjustment of microkeratome and laser parameters for LASIK after CXL and indirectly endorses the theory of a direct stiffening effect of CXL.

  3. Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System

    CERN Document Server

    Gentile, C A; Hartfield, J W; Hawryluk, R J; Hegeler, F; Heitzenroeder, P J; Jun, C H; Ku, L P; Lamarche, P H; Myers, M C; Parker, J J; Parsells, R F; Payen, M; Raftopoulos, S; Sethian, J D

    2002-01-01

    The Princeton Plasma Physics Laboratory (PPPL), in collaboration with the Naval Research Laboratory (NRL), is currently investigating various novel materials (single crystal silicon, , and ) for use as electron-beam transmission windows in a KrF excimer laser system. The primary function of the window is to isolate the active medium (excimer gas) from the excitation mechanism (field-emission diodes). Chosen window geometry must accommodate electron energy transfer greater than 80% (750 keV), while maintaining structural integrity during mechanical load (1.3 to 2.0 atm base pressure differential, approximate 0.5 atm cyclic pressure amplitude, 5 Hz repetition rate) and thermal load across the entire hibachi area (approximate 0.9 W centre dot cm superscript ''-2''). In addition, the window must be chemically resistant to attack by fluorine free-radicals (hydrofluoric acid, secondary). In accordance with these structural, functional, and operational parameters, a 22.4 mm square silicon prototype window, coated w...

  4. Results of excimer laser photorefractive keratectomy for the correction of myopia at Cedars-Sinai Medical Center: 1993

    Science.gov (United States)

    Maguen, Ezra I.; Salz, James J.; Nesburn, Anthony B.; Warren, Cathy; Macy, Jonathan I.; Papaioannou, Thanassis; Hofbauer, John; Berlin, Michael S.

    1994-06-01

    This report summarizes the authors' 3-year experience with excimer laser photorefractive keratectomy (PRK) on 240 eyes of 161 patients. With constant laser emission parameters, nitrogen (N2) flow across the cornea was used on 79 eyes while 161 eyes had no N2 flow. 74 eyes were operated on without fixation with a suction ring. Postoperative pain management included patching and oral analgesics in 77 eyes and the use of topical Diclofenac or Ketorolac, and a therapeutic soft contact lens in 163 eyes. Follow up ranged from 1 month (206 eyes) to 36 months (10 eyes).

  5. Terraced copper growth deposited onto Teflon AF1600 by the excimer laser irradiation of Cu(hfac)TMVS

    Energy Technology Data Exchange (ETDEWEB)

    Popovici, D.; Piyakis, K.; Sacher, E.; Meunier, M. [Ecole Polytechnique, Montreal, Quebec (Canada)

    1996-12-31

    The authors are studying the feasibility of constructing Cu/fluoropolymer multilayer devices, in an effort to reduce both metal R and insulator C, a necessary condition in VLSI and GSI microelectronic applications. The laser chemical vapor deposition (LCVD) of the organometallic precursor Cu(hfac)TMVS (hexafluoroacetylacetonate)(trimethylvinylsilane) is used to grow copper films on a Teflon AF1600 substrate. Exposure to excimer laser radiation at 248 nm results in a terraced copper growth. A simple model, based on interference effects in the Teflon and copper layers, is presented to account for this structure.

  6. Hydroxyapatite and bioactive glass surfaces for fiber reinforced composite implants via surface ablation by Excimer laser.

    Science.gov (United States)

    Kulkova, Julia; Moritz, Niko; Huhtinen, Hannu; Mattila, Riina; Donati, Ivan; Marsich, Eleonora; Paoletti, Sergio; Vallittu, Pekka K

    2017-11-01

    In skeletal reconstructions, composites, such as bisphenol-A-glycidyldimethacrylate resin reinforced with glass fibers, are potentially useful alternatives to metallic implants. Recently, we reported a novel method to prepare bioactive surfaces for these composites. Surface etching by Excimer laser was used to expose bioactive glass granules embedded in the resin. The purpose of this study was to analyze two types of bioactive surfaces created by this technique. The surfaces contained bioactive glass and hydroxyapatite granules. The selected processing parameters were adequate for the creation of the surfaces. However, the use of porous hydroxyapatite prevented the complete exposure the granules. In cell culture, for bioactive glass coatings, the pattern of proliferation of MG63 cells was comparable to that in the positive control group (Ti6Al4V) while inferior cell proliferation was observed on the surfaces containing hydroxyapatite granules. Scanning electron microscopy revealed osteointegration of implants with both types of surfaces. The technique is suitable for the exposure of solid bioactive glass granules. However, the long-term performance of the surfaces needs further assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Excimer laser phototherapeutic keratectomy for the treatment of clinically presumed fungal keratitis.

    Science.gov (United States)

    Li, Liang-Mao; Zhao, Li-Quan; Qu, Ling-Hui; Li, Peng

    2014-01-01

    This retrospective study was to evaluate treatment outcomes of excimer laser phototherapeutic keratectomy (PTK) for clinically presumed fungal keratitis. Forty-seven eyes of 47 consecutive patients underwent manual superficial debridement and PTK. All corneal lesions were located in the anterior stroma and were resistant to medication therapy for at least one week. Data were collected by a retrospective chart review with at least six months of follow-up data available. After PTK, infected corneal lesions were completely removed and the clinical symptoms resolved in 41 cases (87.2%). The mean ablation depth was 114.39 ± 45.51  μ m and diameter of ablation was 4.06 ± 1.07 mm. The mean time for healing of the epithelial defect was 8.8 ± 5.6 days. Thirty-four eyes (82.9%) showed an improvement in best spectacle-corrected visual acuity of two or more lines. PTK complications included mild to moderate corneal haze, hyperopic shift, irregular astigmatism, and thinning cornea. Six eyes (12.8%) still showed progressed infection, and conjunctival flap covering, amniotic membrane transplantation, or penetrating keratoplasty were given. PTK is a valuable therapeutic alternative for superficial infectious keratitis. It can effectively eradicate lesions, hasten reepithelialization, and restore and preserve useful visual function. However, the selection of surgery candidates should be conducted carefully.

  8. Intraoperative videokeratography in penetrating keratoplasty and excimer laser-assisted lamellar keratoplasty for keratoconus.

    Science.gov (United States)

    Spadea, Leopoldo; Fiasca, Arianna; Federici, Simone

    2010-09-01

    To evaluate the usefulness of intraoperative computerized corneal topographic data in excimer laser-assisted lamellar keratoplasty (ELLK) and penetrating keratoplasty (PK). Prospective, comparative, interventional case series. Intra- and postoperative videokeratography (Keratron Scout) evaluation was performed on 30 eyes of 30 consecutive patients affected by keratoconus (16 men and 14 women; mean age 32.63±8.02 years) submitted to ELLK (15 eyes) using 16 interrupted 10-0 nylon stitches or to PK (15 eyes) using a 12-bite 10-0 nylon double-running continuous suture. In the ELLK group, the mean intraoperative keratometric astigmatism was 12.06±4.86 diopters (D), which changed to 5.19±2.51 D after topography-guided intraoperative suture adjustment. In the PK group, intraoperative keratometric astigmatism was 10.18±3.88 D, which changed to 3.49±0.41 D. After 24 months (sutures out), the mean videokeratographic keratometric astigmatism was 3.35±1.96 D in the ELLK group and 3.37±0.92 D in the PK group. The Alpins method of vector analysis showed some significant changes especially in the ELLK group. In keratoplasty surgery, videokeratography is useful for suture adjustment. In the PK group, using a double-running suture technique, the postoperative astigmatism (after all sutures were removed) was similar to the astigmatism measured intraoperatively by videokeratography. Copyright 2010, SLACK Incorporated.

  9. Insight into excimer laser crystallization exploiting ellipsometry: Effect of silicon film precursor

    Energy Technology Data Exchange (ETDEWEB)

    Losurdo, Maria [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR and INSTM sez. Bari, Via Orabona 4, 70125 Bari (Italy)], E-mail: maria.losurdo@ba.imip.cnr.it; Giangregorio, Maria M.; Sacchetti, Alberto; Capezzuto, Pio; Bruno, Giovanni [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR and INSTM sez. Bari, Via Orabona 4, 70125 Bari (Italy); Mariucci, Luigi; Fortunato, Guglielmo [IFN-CNR, Via Cineto Romano, 42 - 00156 Rome (Italy)

    2007-07-16

    The optical diagnostic of spectroscopic ellipsometry is shown to be an effective tool to investigate the mechanism of excimer laser crystallization (ELC) of silicon thin films. A detailed spectroscopic ellipsometric investigation of the microstructures of polycrystalline Si films obtained on SiO{sub 2}/Si wafers by ELC of a-Si:H and nc-Si films deposited, respectively, by SiH{sub 4} plasma enhanced chemical vapor deposition (PECVD) and SiF{sub 4}-PECVD is presented. It is shown that ellipsometric spectra of the pseudodielectric function of polysilicon thin films allows to discern the three different ELC regimes of partial melting, super lateral growth and complete melting. Exploiting ellipsometry and atomic force microscopy, it is shown that ELC of nc-Si has very low energy density threshold of 95 mJ/cm{sup 2} for complete melting, and that re-crystallization to large grains of {approx} 2 {mu}m can be achieved by multi-shot irradiation at an energy density as low as 260 mJ/cm{sup 2} when using nc-Si when compared to 340 mJ/cm{sup 2} for the ELC of a-Si films.

  10. Excimer Laser Phototherapeutic Keratectomy for the Treatment of Clinically Presumed Fungal Keratitis

    Directory of Open Access Journals (Sweden)

    Liang-Mao Li

    2014-01-01

    Full Text Available This retrospective study was to evaluate treatment outcomes of excimer laser phototherapeutic keratectomy (PTK for clinically presumed fungal keratitis. Forty-seven eyes of 47 consecutive patients underwent manual superficial debridement and PTK. All corneal lesions were located in the anterior stroma and were resistant to medication therapy for at least one week. Data were collected by a retrospective chart review with at least six months of follow-up data available. After PTK, infected corneal lesions were completely removed and the clinical symptoms resolved in 41 cases (87.2%. The mean ablation depth was 114.39±45.51 μm and diameter of ablation was 4.06±1.07 mm. The mean time for healing of the epithelial defect was 8.8±5.6 days. Thirty-four eyes (82.9% showed an improvement in best spectacle-corrected visual acuity of two or more lines. PTK complications included mild to moderate corneal haze, hyperopic shift, irregular astigmatism, and thinning cornea. Six eyes (12.8% still showed progressed infection, and conjunctival flap covering, amniotic membrane transplantation, or penetrating keratoplasty were given. PTK is a valuable therapeutic alternative for superficial infectious keratitis. It can effectively eradicate lesions, hasten reepithelialization, and restore and preserve useful visual function. However, the selection of surgery candidates should be conducted carefully.

  11. [193 excimer laser trepanation in perforating keratoplasty. Report of 70 patients].

    Science.gov (United States)

    Naumann, G O; Seitz, B; Lang, G K; Langenbucher, A; Kus, M M

    1993-10-01

    In penetrating keratoplasty, trephination with the 193 nm excimer laser may help avoid the differences in the deformation of the donor and recipient wound margins which occur with the conventional procedure. By varying the shape of the "open metal mask", other cut configurations can be achieved besides circular. Thus, "vertical tilt" and "horizontal torsion", both potential reasons for persistent long-term astigmatism after PK, may be minimized. Following experimental studies, the authors present the results obtained in their first 70 consecutive patients. 38 women and 32 men were treated (mean age 60.6 years, range 17 to 89 years). Indications were corneal processes without vascularization: Fuchs' dystrophy (n = 32), other stromal dystrophies (n = 5), secondary corneal endothelial decompensation (n = 6), keratoconus (n = 15), nonvascularized corneal scars (n = 4) and miscellaneous (n = 8 ). We used elliptical metal masks with/without orientation teeth and circular masks with four and eight orientation teeth, respectively. The HeNe aiming beam was manually controlled by a micromanipulator ("joystick"). The technical data of the laser were as follows: spot mode, 1.5 x 1.5 mm; repetition rate 30/sec and 25/sec, respectively; pulse energy 15-25 mJ; mean number of pulses 6407 (recipient) and 9150 (donor). With an elliptical outline, wound closure was usually achieved with single sutures. With a circular outline with orientation teeth, wound closure was most commonly achieved with a double running suture. Patients were prospectively documented using modified Erlangen record sheets. Follow-up ranged from 3 months to 3.4 years (mean 11.4 months). With two exceptions, penetration of the anterior chamber with the 193 nm excimer laser was accomplished without deformation of the cut edges. The elliptical outline facilitated fitting of the graft into the recipient wound bed, and the orientation teeth made fitting even easier. Initial intraoperative complications due to

  12. Comparison of 3D surfaces produced by 248-nm and 193-nm excimer laser radiation

    Science.gov (United States)

    Toenshoff, Hans K.; Graumann, Christoph; Rinke, Marcus; Hesener, Hanno; Kulik, Christian

    1998-10-01

    Currently there is a strong demand for refractive optical elements made from glass in 21/2D and 3D-structures. Due to the characteristics of brittle materials like glass, only a limited number of manufacturing methods can be used to machine these materials with sub-micron resolution. Thus, current microstructures made out of glass are mainly manufactured by photolithography and etching process. Lithography techniques are only for economic purposes for a series production, but is not suitable for manufacturing prototypes or a small series. Micromachining done with Excimer Lasers in combination with high precision CNC- controlled handling systems offers flexible design possibilities for optical components. Due to the limitations of conventional machining techniques for brittle materials, a new laser machining system for material processing at a wavelength of 193 nm has been designed and built. The better absorption of 193 nm compared to 248 nm or larger wavelengths leads to damage free microstructuring of most glasses. Data generation for the volume to be ablated starts with the mathematical description of the surface shape of the optical component. The contour can be derived from a mathematical function or individual xyz-data point information from any CAD-program. A pre-processor calculates the CNC-data for laser triggering, xyz-table and the CNC- mask control. Each laser pulse leads to a material removal, defined by the illuminated surface on the workpiece as well as the energy density. Superposition or overlapping of pulses allows the creation of the desired surface. The surface roughness is determined by the wavelength as well as the chosen ablation strategy. To achieve best results, the process has to be carefully adjusted for a specific material. This technique is a sufficient method for structuring grooves in ceramics or glass as well as producing aspherical transparent optical surfaces or micro lens arrays. This paper shall describe the potential of 193 nm

  13. Effect of time sequences in scanning algorithms on the surface temperature during corneal laser surgery with high-repetition-rate excimer laser.

    Science.gov (United States)

    Mrochen, Michael; Schelling, Urs; Wuellner, Christian; Donitzky, Christof

    2009-04-01

    To investigate the influence of temporal and spatial spot sequences on the ocular surface temperature increase during corneal laser surgery with a high-repetition-rate excimer laser. Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland, and WaveLight AG, Erlangen, Germany. An argon-fluoride excimer laser system working at a repetition rate of 1050 Hz was used to photoablate bovine corneas with various myopic, hyperopic, and phototherapeutic ablation profiles. The temporal distribution of ablation profiles was modified by 4 spot sequences: line, circumferential, random, and an optimized scan algorithm. The increase in ocular surface temperature was measured using an infrared camera. The maximum and mean ocular surface temperature increases depended primarily on the spatial and temporal distribution of the spots during photoablation and the amount of refractive correction. The highest temperature increases were with the line and circumferential scan sequences. Significant lower temperature increases were found with the optimized and random scan algorithms. High-repetition-rate excimer laser systems require spot sequences with optimized temporal and spatial spot distribution to minimize the increase in ocular surface temperature. An ocular surface temperature increase will always occur depending on the amount of refractive correction, the type of ablation profile, the radiant exposure, and the repetition rate of the laser system.

  14. Excimer laser-assisted recanalisation of femoral arterial stenosis or occlusion caused by the use of Angio-Seal

    Energy Technology Data Exchange (ETDEWEB)

    Steinkamp, H.J.; Werk, M.; Beck, A.; Teichgraeber, U.; Haufe, M.; Felix, R. [Dept. of Radiology, Humboldt Univ. Berlin (Germany)

    2001-08-01

    The aim of this study was to demonstrate the effect of excimer laser and balloon angioplasty of femoral artery stenosis and occlusion after use of a haemostatic puncture closure device. A haemostatic puncture closure device (Angio-Seal) was used in 6000 patients after diagnostic or therapeutic artery catheterisation. In 34 of those patients symptoms of peripheral artery disease occurred. Sixteen of those 34 cases were transferred to our clinic for excimer laser angioplasty. All 16 patients presented with symptoms of acute peripheral artery disease within 1-14 days: superficial femoral artery (SFA) occlusions (4 cases); superficial femoral artery stenosis (3 cases); high-grade stenosis of the common femoral artery (CFA; 3 cases); high-grade stenosis of CFA; SFA and profund femoral artery (PFA; 3 cases); and occlusions of CFA, SFA and PFA (3 cases). Before any procedure was performed, informed consent was given by the patient, which included the use of the Angio-Seal closure device. Every patient who had to undergo recanalisation procedures gave additional informed consent which especially included the usage of the excimer laser for recanalisation. A measurement of the walking distance, ankle-brachial systolic pressure index (ABI) and diagnostic angiography was performed in 13 cases before and immediate after as well as 3 and 6 months after therapeutic percutaneous transluminal laser angioplasty followed by balloon angioplasty (PTLA/PTA). In 3 patients the risks of PTLA/PTA was considered too high; those patients underwent surgical repair. Angiographic and clinical improvement was achieved in 13 of 13 patients. The mean walking distance increased from 81 to >400 m. The average ankle-brachial systolic pressure index (ABI) increased from 0.47 to 0.84. One patient developed a dissection of the SFA, and in 1 case a peripheral embolisation was seen. The PTLA/PTA technique is a successful therapeutic option for patients with femoral artery occlusion or high-grade stenosis

  15. Effects of excimer laser annealing on low-temperature solution based indium-zinc-oxide thin film transistor fabrication

    Directory of Open Access Journals (Sweden)

    Chao-Nan Chen

    2015-04-01

    Full Text Available A Solution Based Indium-Zinc-Oxide thin-film transistor (TFT with a field-effect mobility of 0.58 cm2/Vs, a threshold voltage of 2.84 V by using pulse laser annealing processes. Indium-zinc-oxide (IZO films with a low process temperature were deposited by sol-gel solution based method and KrF excimer laser annealing (wavelength of 248 nm. Solution based indium-zinc-oxide (IZO films usually needs high temperature about 500 °C post annealing in a oven. KrF excimer laser annealing shows advantages of low temperature process, the less process time deceases to only few seconds was used to replace the high temperature process. IZO thin films suffering laser irradiation still keeps the amorphous film quality by transmission electron microscopy (TEM diffraction pattern analysis. It could be expected this technology to large-area flexible display, in the future.

  16. A comparative study of via drilling and scribing on PEN and PET substrates for flexible electronic applications using excimer and Nd:YAG laser sources

    NARCIS (Netherlands)

    Mandamparambil, R.; Fledderus, H.; Brand, J. van den; Saalmink, M.; Kusters, R.; Podprocky, T.; Steenberge, G. van; Baets, J. de; Dietzel, A.H.

    2009-01-01

    A study on via drilling and channel scribing on PEN and PET substrates for flexible electronic application is discussed in this paper. For the experiments, both KIF excimer laser (248 nm) and frequency tripled Nd:YAG (355 nm) laser are used. Different measurement techniques like optical microscopy,

  17. Corneal haze induced by excimer laser photoablation in rabbits is reduced by preserved human amniotic membrane graft

    Science.gov (United States)

    Wang, Ming X.; Gray, Trevor; Prabhasawat, Pinnita; Ma, Xiong; Culbertson, William; Forster, Richard; Hanna, Khalil; Tseng, Scheffer C. G.

    1998-06-01

    We conducted a study to determine if preserved human amniotic membrane can reduce corneal haze induced by excimer laser photoablation. Excimer photoablation was performed bilaterally on 40 New Zealand white rabbits with a 6 mm ablation zone and 120 micrometer depth (PTK) using the VISX Star. One eye was randomly covered with a preserved human amniotic membrane and secured using four interrupted 10 - 0 nylon sutures; the other eye served as control. The amniotic membranes were removed at one week, and the corneal haze was graded with a slit-lamp biomicroscopy by three masked corneal specialists (WC, KH and RF) biweekly for the ensuing 12 weeks. Histology and in situ TUNEL staining (for fragmented DNA as an index for apoptosis) was performed at days 1, 3 and 7 and at 12 weeks. One week after excimer photoablation, the amniotic membrane-covered corneas showed more anterior stromal edema, which resolved at the second week. A consistent grading of organized reticular corneal haze was noted among the three masked observers. Such corneal haze peaked at the seventh week in both groups. The amniotic membrane-covered group showed statistically significant less corneal haze (0.50 plus or minus 0.15) than the control groups (1.25 plus or minus 0.35) (p less than 0.001). The amniotic membrane-covered corneas had less inflammatory response at days 1 and 3, showing nearly nil DNA fragmentation on keratocytes on the ablated anterior stromal and less stromal fibroblast activation. There is less altered epithelial cell morphology and less epithelial hyperplasia at 1 week in these amniotic membrane-treated eyes. We concluded from this study that amniotic membrane matrix is effective in reducing corneal haze induced by excimer photoablation in rabbits and may have clinical applications.

  18. Single application on iris localization technology in excimer laser for astigmatism

    Directory of Open Access Journals (Sweden)

    Jun-Hua Hao

    2014-06-01

    Full Text Available AIM:To discuss the single application on iris localization technology in excimer laser for the treatment of astigmatism. METHODS:Totally 203 cases(406 eyesof laser in situ keratomileusis(LASIKin the treatment of compound myopic astigmatism patients were operated from November 2011 to November 2012 in our hospital. They were divided into two groups. One was observation group using iris localization and the other was control group using routine operation. Patients in the observation group of 100 cases(200 eyes, aged 18-43 years old, spherical diopter was -1.25 to -8.75D, astigmatism was -1.0 to -3.25D. In control group, 103 patients(206 eyes, aged 19-44 years old, spherical diopter was -1.75-9.50D, astigmatism was -1.0 to -3.25D. The patients in the observation group before the application of WaveScan aberrometer check for iris image, spherical lens, cylindrical lens and astigmatism axis data operation, only single application of iris location, without using wavefront aberration guided technology, laser cutting patterns for conventional LASIK model, spherical, cylindrical mirror and astigmatism axis data source to preoperative wavefront aberration results. The control group received routine LASIK. It was applicated comprehensive optometry optometry respectively to examine astigmatism and axial, based on the computer analysis during the preoperative, 1wk after the operation, and 6mo. Analysis of using SPSS 17 statistical software, it was independent-sample t test between the two groups of residual astigmatism and astigmatism axis. RESULTS:Postoperative residual astigmatism, the observation group was significantly better than the control group. Astigmatism axial measurement after operation, the observation group was significantly less than that of the control group. Postoperative visual acuity at 6mo, the observation group was better than that of the control group. The difference was statistically significant. CONCLUSION: For patients who cannot

  19. Pigmentation above the constitutive level: an indicator of excimer laser radiation-induced erythema in Koreans.

    Science.gov (United States)

    Choi, Jee-Woong; Na, Se-Young; Chung, Mi-Young; Na, Jung-Im; Huh, Chang-Hun; Youn, Sang-Woong; Kang, Hee-Young; Park, Kyoung-Chan

    2012-07-01

    Ultraviolet (UV) irradiation induces skin erythema, but it is not clear which factors have the greatest effects on UV sensitivity. Six healthy Korean adult men were enrolled and their melanin index (MI) and increment of erythema index (ΔEI) were measured. In each individual, 12 different sites were selected and 36 spots were irradiated with a single shot of monochromatic excimer laser with a dose of 350 mJ/cm(2) . The sites were categorized into three groups based on the cumulative sun exposure: UZ, unexposed zones; FEZ, frequently exposed zones; and IEZ, intermittently exposed zones. The sun exposure indexes (SEI) were also calculated based on previously described methods. ΔEI, MI and SEI were measured and calculated. The ΔEI of UZ was significantly higher than that of FEZ, but lower than that of IEZ. In general, there was a significant relationship between ΔEI and MI (R(2) = 0.135). However, IEZ did not show significant results. In contrast, there was a stronger relationship between ΔEI and SEI (R(2) = 0.344). Overall, the values were significantly higher for the SEI (0.541 [UZ], 0.281 [IEZ] and 0.228 [FEZ]) than for MI (0.311 [UZ], 0.011 [IEZ] and 0.073 [FEZ]). There were significant site variations in UV sensitivity along with skin pigmentation. In addition, significant differences were observed according to the exposure frequency. The SEI was found to be strongly correlated with UV sensitivity. These results suggest that the induced level of pigmentation above the constitutive level will be a better indicator for UV sensitivity than baseline MI. © 2012 Japanese Dermatological Association.

  20. Excimer laser micropatterning of freestanding thermo-responsive hydrogel layers for cells-on-chip applications

    Science.gov (United States)

    Santaniello, Tommaso; Martello, Federico; Tocchio, Alessandro; Gassa, Federico; Webb, Patrick; Milani, Paolo; Lenardi, Cristina

    2012-10-01

    We report a novel reliable and repeatable technologic manufacturing protocol for the realization of micro-patterned freestanding hydrogel layers based on thermo-responsive poly-(N-isopropyl)acrylamide (PNIPAAm), which have potential to be employed as temperature-triggered smart surfaces for cells-on-chip applications. PNIPAAm-based films with controlled mechanical properties and different thicknesses (100-300 µm thickness) were prepared by injection compression moulding at room temperature. A 9 × 9 array of 20 µm diameter through-holes is machined by means of the KrF excimer laser on dry PNIPAAm films which are physically attached to flat polyvinyl chloride (PVC) substrates. Machining parameters, such as fluence and number of shots, are optimized in order to achieve highly resolved features. Micro-structured freestanding films are then easily obtained after hydrogels are detached from PVC by gradually promoting the film swelling in ethanol. In the PNIPAAm water-swollen state, the machined holes’ diameter approaches a slight larger value (30 µm) according to the measured hydrogel swelling ratio. Thermo-responsive behaviour and through-hole tapering characterization are carried out by metrology measurements using an optical inverted and confocal microscope setup, respectively. After the temperature of freestanding films is raised above 32 °C, we observe that the shrinkage of the whole through-hole array occurs, thus reducing the holes’ diameter to less than a half its original size (about 15 µm) as a consequence of the film dehydration. Different holes’ diameters (10 and 30 µm) are also obtained on dry hydrogel employing suitable projection masks, showing similar shrinking behaviour when hydrated and undergone thermo-response tests. Thermo-responsive PNIPAAm-based freestanding layers could then be integrated with other suitable micro-fabricated thermoplastic components in order to preliminary test their feasibility in operating as temperature

  1. Influence of laser beam’s image-plane position on geometry of through-holes in percussion-drilled glass using excimer laser

    Directory of Open Access Journals (Sweden)

    Ales Babnik

    2013-01-01

    Full Text Available We study the influence of a laser beam’s image-plane position relative to the processed surface for the deep-hole, laser-microdrilling of soda-lime glass with an excimer 308-nm laser and mask-projection technique. It is demonstrated that the image-plane position has a significant influence on the hole’s tapering and final depth. Holes with exit diameters up to 10 times smaller than the mask-image diameter are produced in the case of perforation during the appropriate process phase determined by the formation of the plasma plume.

  2. Wettability characteristics of a modified mild steel with CO2, Nd:YAG, excimer and high power diode lasers

    OpenAIRE

    Lawrence, Jonathan; Li, Lin

    1999-01-01

    Interaction of CO2, Nd:YAG, excimer and high-power diode laser radiation with the surface of a common mild steel (EN8) was found to effect changes in the wettability characteristics of the steel, namely changes in the measured contact angle of certain liquids. Such changes were identified as being due to modifications to (i) the surface roughness, (ii) changes in the surface oxygen content and (iii) changes in the surface energy of the mild steel. However, it was found that changes in the wet...

  3. Controllable Change of Photoluminescence Spectra of Silicone Rubber Modified by 193 nm ArF Excimer Laser

    Science.gov (United States)

    Okoshi, Masayuki; Iyono, Minako; Inoue, Narumi

    2009-12-01

    Photoluminescence spectra of silicone rubber ([SiO(CH3)2]n) photochemically modified by a 193 nm ArF excimer laser was found to be controllable. Compared with the modification in air, the photoluminescence spectra could be blueshifted by the modification in vacuum or the additional irradiation of ArF excimer laser in vacuum after the modification in air. To redshift, on the other hand, the additional irradiation of a 157 nm F2 laser in air after the modification in air, the modification in oxygen gas, or the postannealing after the modification in oxygen gas was effective. The blue and redshifts of the photoluminescence were essentially due to the acceleration of reduction and oxidation reactions of silicone rubber, respectively, because the photoluminescence derives its origin from oxygen deficiency centers and peroxy centers of the silica structure in the modified silicone rubber. On the basis of the spectra changes, colorful light-guiding sheets made of silicone rubber under illumination of a 375 nm light-emitting diode were successfully fabricated for cellular phone use.

  4. Corneal lathing using the excimer laser and a computer-controlled positioning system: Part I--Lathing of epikeratoplasty lenticules.

    Science.gov (United States)

    Altmann, J; Grabner, G; Husinsky, W; Mitterer, S; Baumgartner, I; Skorpik, F; Asenbauer, T

    1991-01-01

    Precise lathing of epikeratoplasty lenticules is difficult to achieve with the cryolathe due to unpredictable expansion of the lathing tools and the corneal tissue during the freezing process. In addition, the procedure destroys all viable cells in the transplant thereby possibly contributing to the prolonged period of visual rehabilitation. Non-freezing techniques using the microkeratome or the rotor-trephine, on the other hand, are technically demanding, can cause mechanical damage during cutting or fixation, and, have not given consistently reproducible refractive results. A new system is presented that allows a variable laser ablation of donor corneas into lenticules for aphakic and myopic epikeratoplasty, as well as for lamellar keratoplasty. With the help of a computer-controlled positioning system that uses high-precision micropositioning elements (both translation and rotational stages) the donor cornea is moved, epithelial side down, in a holding device in front of a focused excimer laser beam (ArF, lambda = 193 nm). This photoablation lathing process assures the viability of the stromal cells in the lenticule in close approximation to the treated surface. The user friendly computer software allows the fast and convenient selection of a variety of parameters, such as the diameter of the optical zone, the shape of the wing zone, the refractive power, the central thickness of the lenticule and the overall contour of the transplant. The first laboratory data of lenticules prepared from human corneas with this "Excimer Laser Corneal Shaping System" are presented.

  5. Corneal lathing using the excimer laser and a computer-controlled positioning system: Part II--Variable trephination of corneal buttons.

    Science.gov (United States)

    Husinsky, W; Mitterer, S; Altmann, J; Grabner, G; Baumgartner, I; Skorpik, F; Asenbauer, T

    1991-01-01

    A new system is presented that allows a variable trephination of donor corneas for the preparation of corneal buttons used in penetrating keratoplasty. With the help of a computer-controlled positioning system that uses high-precision micropositioning elements (both translation and rotational stages) the donor cornea is removed, epithelial side up, in a fixation device in front of a focused excimer laser beam (ArF, lambda = 193 nm). User friendly computer software allows the surgeon to select a variety of parameters (diameter, shape, angle of trephination) of the corneal graft. Histological and electron microscopical data of human corneas trephined with this "Excimer Laser Corneal Shaping System" are presented.

  6. Update on excimer laser photorefractive keratectomy (PRK) at Cedars-Sinai Medical Center: two-year experience

    Science.gov (United States)

    Maguen, Ezra I.; Salz, James J.; Warren, Cathy; Papaioannou, Thanassis; Nesburn, Anthony B.; Macy, Jonathan I.; Hofbauer, John; Grundfest, Warren S.

    1993-06-01

    Our two year experience with excimer laser photorefractive keratectomy for the correction of myopia on 160 eyes of 128 patients is described. All eyes were treated with a VISX Twenty- Twenty excimer laser, with the following parameters: radiant exposure 160 mJ/cm2, frequency 5 Hz, ablation zone diameter 5.0 to 5.5 mm, and stromal ablation rate 0.18 to 0.33 (mu) /pulse. A suction fixation ring was used in all cases either with nitrogen flow (79 eyes) or without nitrogen flow (81 eyes) across the cornea. Follow-up ranged from one month (152 eyes) to 24 months (12 eyes). The results are stable between 3 and 24 months with less than 0.25 D change in the mean postoperative spherical equivalents. In eyes with a follow-up of 6 to 24 months, 77% to 100% were 20/40 or better uncorrected, and 84% to 92% were corrected to within +/- 1 D of emmetropia. Further follow-up is needed to assess the long term safety and efficacy of the procedure.

  7. Formation of periodic microswelling structures on silicone rubber surface using ArF excimer laser to realize superhydrophobic property

    Science.gov (United States)

    Nojiri, Hidetoshi; Setyo Pambudi, Wisnu; Okoshi, Masayuki

    2017-07-01

    Periodic microswelling structures were photochemically induced on a silicone rubber surface using a 193 nm ArF excimer laser. Microspheres made of silica glass (SiO2) of 2.5 µm diameter were aligned on the silicone rubber surface during laser irradiation; the laser beam was focused on the silicone surface underneath each microsphere. The height and diameter of the formed microswelling structures were found to be controllable by changing the Ar gas flow rate, single-pulse laser fluence, and laser irradiation time. The chemical bonding of the laser-irradiated sample did not change and thus remained to be a silicone, as analyzed by X-ray photoelectron spectroscopy. As a result, microswelling structures of approximately 1.3 µm height and 1.3 µm diameter were successfully obtained. The contact angles of water on the microstructured silicone were measured to be 150° and larger, clearly indicating superhydrophobicity. The mechanism by which the microswellings form their shape was discussed on the basis of the changes in the focal point and spot size during laser irradiation through the SiO2 microsphere.

  8. Determination of the melting threshold of TiO{sub 2} thin films processed by excimer laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Van Overschelde, O. [Chimie des Interactions Plasma-Surface, Universite de Mons, 23, Place du Parc, 7000 Mons (Belgium); Delsate, T. [Service de Physique Theorique et Mathematique, Universite de Mons, 6 Avenue du champ de Mars, 7000 Mons (Belgium); Snyders, R. [Chimie des Interactions Plasma-Surface, Universite de Mons, 23, Place du Parc, 7000 Mons (Belgium); Materia Nova Research Center, 1 Avenue Copernic, 7000 Mons (Belgium)

    2012-06-15

    Processing surfaces by laser needs an understanding of the mechanisms generated by irradiation. In this work, to gain understanding of the mechanisms occurring during irradiation of TiO{sub 2} thin films by means of KrF excimer laser, we have performed infrared time resolved reflectivity measurements. This experimental investigation revealed modifications of the heating/cooling cycle as a function of the fluence (F). These modifications start appearing for a fluence value of about {approx}0.25 J/cm{sup 2} which is associated with the melting threshold of the film. Additionally, we have solved numerically the heat equation of the system with specific boundary conditions. From these calculations, we have established the thermal history of the film during the 25 ns irradiation pulse. The data reveal that a part of the medium liquefies around a fluence of 0.23 J/cm{sup 2} in good agreement with the experimental data.

  9. Scattered ultraviolet emissions during refractive surgery using a high-frequency, wavefront-optimized excimer laser platform.

    Science.gov (United States)

    Bower, Kraig S; Edwards, Jayson D; Ryan, Denise Sediq; Coe, Charles D; Hope, Robert J; Sliney, David H

    2010-08-01

    To evaluate occupational ultraviolet (UV) exposure during photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) with the Allegretto Wave Eye-Q 400 Hz excimer laser. Walter Reed Center for Refractive Surgery, Washington, DC, USA. Intraoperative UV measurements were performed during PRK with epithelial removal using an Amoils brush, PRK with epithelial removal using 20% ethanol, or femtosecond LASIK. A LaserStar power/energy meter with a silicone detector (model PD-10) was used for the measurements. The maximum pulse energy 25.4 cm from the corneal surface was recorded for each surgical procedure. Measurements were evaluated using a worst-case scenario for exposure of operating room personnel, and the results were compared with the occupational exposure limit set by the International Commission on Non-Ionizing Radiation Protection. Measurements were taken during 15 cases of each procedure. The mean maximum exposure was 129.38 nJ/pulse +/- 79.48 (SD) during brush PRK, 69.72 +/- 68.80 nJ/pulse during ethanol PRK, and 29.17 +/- 13.82 nJ/pulse during LASIK. The mean maximum exposure per eye was 0.085 mJ/cm(2), 0.046 mJ/cm(2), and 0.01 mJ/cm(2), respectively. The worst-case cumulative exposure during a heavy workday of 20 patients (40 eyes) was calculated at 3.92 mJ/cm(2), 1.51 mJ/cm(2), and 0.79 mJ/cm(2) for brush PRK, ethanol PRK, and LASIK, respectively. Results indicate that the excimer laser platform used in the study may yield greater UV exposure than previous systems; however, the levels did not exceed occupational exposure limits. No author has a financial or proprietary interest in any material or method mentioned. Published by Elsevier Inc.

  10. Improving the ablation efficiency of excimer laser systems with higher repetition rates through enhanced debris removal and optimized spot pattern.

    Science.gov (United States)

    Arba-Mosquera, Samuel; Klinner, Thomas

    2014-03-01

    To evaluate the reasons for the required increased radiant exposure for higher-repetition-rate excimer lasers and determine experimentally possible compensations to achieve equivalent ablation profiles maintaining the same single-pulse energies and radiant exposures for laser repetition rates ranging from 430 to 1000 Hz. Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany. Experimental study. Poly(methyl methacrylate) (PMMA) plates were photoablated. The pulse laser energy was maintained during all experiments; the effects of the flow of the debris removal, the shot pattern for the correction, and precooling the PMMA plates were evaluated in terms of achieved ablation versus repetition rate. The mean ablation performance ranged from 88% to 100%; the variability between the profile measurements ranged from 1.4% to 6.2%. Increasing the laser repetition rate from 430 Hz to 1000 Hz reduced the mean ablation performance from 98% to 91% and worsened the variability from 1.9% to 4.3%. Increasing the flow of the debris removal, precooling the PMMA plates to -18°C, and adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the variability. Only adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the mean ablation performance. The ablation performance of higher-repetition-rate excimer lasers on PMMA improved with improvements in the debris removal systems and shot pattern. More powerful debris removal systems and smart shot patterns in terms of thermal response improved the performance of these excimer lasers. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Species-resolved laser-probing investigations of the hydrodynamics of KrF excimer and copper vapor laser ablation processing of materials

    Science.gov (United States)

    Ventzek, Peter L. G.; Gilgenbach, Ronald M.; Ching, Chi H.; Lindley, R. A.

    1993-06-01

    Hydrodynamic phenomena from KrF excimer laser ablation (10-3-20 J/cm2) of polyimide, polyethyleneterephthalate, and aluminum are diagnosed by laser beam deflection, schlieren photography, shadowgraphy, laser-induced-fluorescence and dye-laser- resonance absorption photography (DLRAP). Experiments were performed in vacuum and gaseous environments (10-5 to 760 Torr). In vacuum, the DLRAP diagnostic shows species-resolved plume expansion which is consistent with that of a reflected rarefaction wave. Increasing the background gas pressure reveals the formation of sound/shock compared to CN in the laser-ablated polyimide (Vespel) plume/shock in inert (e.g. argon) and reactive (e.g. air) gases. At low pressures (less than 10 Torr) Al and CN species are in close contact with the shock front. As the pressure increases, the species front tends to recede, until at high pressures (over 200 Torr) the species are restrained to only a few mm above the target surface. After sufficient expansion, Al and CN are no longer detectable; only the shadowgraph of the hot gas plume remains. Since CN is observable in both inert and reactive environments, it can be concluded that CN is not a reaction product between the background gas and the ablated species. By way of comparison to excimer laser ablation processing of materials, copper vapor laser machined polyimide and polymethylmethacrylate (transparent to green and yellow copper vapor laser light) are also investigated. The two polymers are observed to have markedly different machined surfaces. Hydrodynamic effects for the copper vapor laser machined materials are investigated using HeNe laser beam deflection.

  12. Excimer laser phototherapeutic keratectomy : Indications, results and its role in the Indian scenario

    Directory of Open Access Journals (Sweden)

    Rao Srinivas

    1999-01-01

    Full Text Available PURPOSE: To report indications, technique, and results of excimer phototherapeutic keratectomy (PTK, and describe possible reasons for the small numbers of such procedures performed in a referral institute in India. METHODS: Retrospective review of case records of 10 patients (11 eyes who underwent excimer PTK at our institute between February 1994 and September 1997. RESULTS: Corneal scars were the most common indication for treatment. Best-corrected visual acuity (BCVA improved in 6 eyes (mean: 2 lines of Snellen acuity. All eyes had BCVA > or = 6/12 after treatment. None of the patients experienced loss of BCVA after treatment. Unaided visual acuity improved in 3 eyes and decreased in 2 eyes. Change in spherical equivalent refraction > or = 1 diopter occurred in 77.8% of eyes after treatment. Treating central corneal scars resulted in a significant hyperopic shift in refraction. CONCLUSIONS: Excimer PTK is a safe and effective procedure for the treatment of superficial corneal opacities. Post-treatment ametropia may require further correction with optical aids. Inappropriate referrals, deep corneal scars, and cost of the procedure could have contributed to the small numbers of PTK performed at our institute. Improved understanding of procedural strengths and limitations could lead to increased use of this procedure, with satisfying results in selected patients.

  13. Effects of 308 nanometer excimer laser energy on 316 L stainless-steel stents: implications for laser atherectomy of in-stent restenosis.

    Science.gov (United States)

    Burris, N; Lippincott, R A; Elfe, A; Tcheng, J E; O'Shea, J C; Reiser, C

    2000-11-01

    To determine the effects of the incidental exposure of stents to pulsed 308 nanometer ultraviolet excimer laser energy. Five types of 316 L stainless-steel coronary stents were subjected to two types of study. First, for endurance testing, sixty stents were deployed in 3.0Eth 4.0 mm polymer tubes in three geometries. Up to 1,000 laser pulses were delivered while advancing a 2.0 mm eccentric catheter through the lumen of the stent. These stents were next subjected to 400 million simulated heartbeats and then analyzed for metal etching and fatigue. Second, six additional stents were irradiated with 1,000 pulses underwater and then analyzed for particulates, anions and cations liberated from the stent. Photomicroscopy revealed surface etching on a number of stents. Two stent models exhibited multiple strut fractures at the strut joints in both test samples and controls. In no case was a break observed at the site of laser-stent interaction. Breakage frequency was not significantly different between lazed stents and controls. Lazed stents produced a mean of 14 micrograms of sodium and 4 micrograms of iron more than controls. No excess particulates were detected. Under model conditions typical of clinical use, excimer laser treatment does not alter stainless-steel stent endurance or liberate clinically significant material from the stent.

  14. AFM study of excimer laser patterning of block-copolymer: Creation of ordered hierarchical, hybrid, or recessed structures

    Energy Technology Data Exchange (ETDEWEB)

    Švanda, Jan; Siegel, Jakub; Švorčík, Vaclav; Lyutakov, Oleksiy, E-mail: lyutakoo@vscht.cz

    2016-05-15

    Highlights: • Combination of bottom-up (BCP separation) and top-down (laser patterning) technologies allows obtaining hierarchical structures. • Surface morphologies were determined by the order of patterning steps (laser modification, annealing, surface reconstruction). • Tuning the order of steps enables the reorientation of BCP domain at large scale, fabrication of hierarchical, hybrid or recessed structures. • The obtained structures can find potential applications in nanotechnology, plasmonics, information storage, sensors and smart surfaces. - Abstract: We report fabrication of the varied range of hierarchical structures by combining bottom-up self-assembly of block copolymer poly(styrene-block-vinylpyridine) (PS-b-P4VP) with top-down excimer laser patterning method. Different procedures were tested, where laser treatment was applied before phase separation and after phase separation or phase separation and surface reconstruction. Laser treatment was performed using either polarized laser light with the aim to create periodical pattern on polymer surface or non-polarized light for preferential removing of polystyrene (PS) part from PS-b-P4VP. Additionally, dye was introduced into one part of block copolymer (P4VP) with the aim to modify its response to laser light. Resulting structures were analyzed by XPS, UV–vis and AFM techniques. Application of polarized laser light leads to creation of structures with hierarchical, recessed or hybrid geometries. Non-polarized laser beam allows pronouncing the block copolymer phase separated structure. Tuning the order of steps or individual step conditions enables the efficient reorientation of block-copolymer domain at large scale, fabrication of hierarchical, hybrid or recessed structures. The obtained structures can find potential applications in nanotechnology, photonics, plasmonics, information storage, optical devices, sensors and smart surfaces.

  15. Electronic and crystalline structure of Si/SiO 2 interface modified by ArF excimer laser

    Science.gov (United States)

    Cháb, V.; Lukeš, I.; Ondřejček, M.; Jiříček, P.

    The native oxide layers on Si(100) surface were irradiated under UHV conditions by an ArF excimer laser pulses with energy density varied between melting and evaporating thresholds. The resulting changes were studied by LEED, AES and UPS. The increase of the energy density up to evaporation threshold results in the recrystallisation of native oxide layer. The pulses with energy densities just above the evaporation threshold ablate the top layer leaving an ordered and atomicaly clean surface. The observed (1x1) surface reconstruction is probably stabilised by strains introduced during rapid melting and quenching of the topmost layers. The surface electronic structure is dominated by random satisfaction of dangling bonds swearing a well defined surface states observed on (2x1)Si(100) surface.

  16. Synthesis and properties of Ag/ZnO core/shell nanostructures prepared by excimer laser ablation in liquid

    Directory of Open Access Journals (Sweden)

    Yan Zhao

    2015-08-01

    Full Text Available Ag/ZnO core/shell nanostructure was synthesised by a 248-nm KrF excimer pulsed laser ablation in a liquid solution for the first time. It was found that the surface plasma resonance absorption of the Ag/ZnO core/shell nanostructures can be tuned by the thickness of the ZnO shell, which is in agreement with the finite difference in the time domain simulation. Furthermore, the ultraviolet emission spectrum of the Ag/ZnO core/shell nanostructures was stronger and blue-shifted compared with that of pure ZnO nanoparticles. This interesting photoluminescent phenomenon is analysed in detail and a possible explanation is proposed.

  17. Efficacy and safety of ab interno excimer laser trabeculotomy in primary open-angle glaucoma: two years of follow-up.

    Science.gov (United States)

    Babighian, Silvia; Rapizzi, Emilio; Galan, Alessandro

    2006-01-01

    Ab interno trabeculotomy was performed using the recently developed XeCl excimer laser in 21 eyes of 21 patients with primary open-angle glaucoma refractory to medical therapy. The patients were followed at the Eye Department of S. Antonio Hospital in Padova, for an average of 25.3 +/- 1.3 months. Intraocular pressure (IOP), visual acuity and ocular complications were evaluated. The laser procedure was quick and relatively easy, with minimal manipulation of tissues; complications were clinically insignificant. At the last follow-up, a marked IOP-lowering effect compared to baseline was observed (from 24.8 +/- 2.0 to 16.9 +/- 2.1 mm Hg; -31.8%, p interno excimer laser trabeculotomy seems effective to decrease IOP, serves to reduce the number of antiglaucoma medications and is relatively safe, proving to be a promising therapeutic option in glaucoma surgery. Copyright 2006 S. Karger AG, Basel.

  18. ArF excimer laser-induced deposition of Ag/C nanocomposite thin films in the presence of n-Hexane

    Energy Technology Data Exchange (ETDEWEB)

    Gondal, Mohammed Ashraf, E-mail: magondal@kfupm.edu.sa [Laser Research Group, Physics Department and Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Fajgar, Radek [Institute of Chemical Process Fundamentals, 16502 Prague (Czech Republic); Chang, Xiaofeng [Laser Research Group, Physics Department and Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Institute of Chemical Process Fundamentals, 16502 Prague (Czech Republic); College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211100 (China); Shen, Kai [College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211100 (China); Xu, Qingyu [Department of Physics, Southeast University, Nanjing 211189 (China)

    2014-08-30

    Highlights: • A new excimer laser ablation process was proposed to fabricate Ag/C thin film. • The size of Ag nanoparticles is ranging from 5 to 20 nm. • The ratios of Ag to C can be controlled by adjusting the pressure of n-Hexane. • The graphite-like structure of carbonaceous products was confirmed. - Abstract: Ag/C nanocomposite thin films with different Ag/C molar ratios have been prepared using ArF excimer laser-induced ablation process and silver target under n-Hexane atmosphere. The morphology, crystal structure and composition of as-deposited Ag/C nanocomposite thin films were investigated with high resolution electronic microscopic techniques (including scanning electron microscopy and transmission electron microscopy) and energy-dispersive X-ray spectroscopy, respectively. Laser Raman spectroscopy and Fourier transform infrared spectroscopy techniques were also applied to characterize the final carbonaceous products generated from n-Hexane under laser ablation process. The optical emission of the plume caused by the interaction between excimer laser and silver target in the presence of n-Hexane was studied to understand the possible reaction process. The UV–vis absorption of as-deposited Ag/C thin films, which is attributed to the surface plasmonic excitation, was also investigated in the present work.

  19. Surface studies on benzophenone doped PDMS microstructures fabricated using KrF excimer laser direct write lithography

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Madhushree Bute; Shinde, Shashikant D. [Department of Physics, University of Pune, Pune 411007 (India); Bodas, Dhananjay [Centre for Nanobioscience, Agharkar Research Institute, Agharkar road, Pune 411004 (India); Patil, K.R. [Center for Materials Characterization, National Chemical Laboratories, Pune 411008 (India); Sathe, V.G. [UGC DAE Inter University Consortium, Indore 452017 (India); Adhi, K.P. [Department of Physics, University of Pune, Pune 411007 (India); Gosavi, S.W., E-mail: swg@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411007 (India)

    2014-09-30

    Graphical abstract: - Highlights: • Use of KrF Laser micromachining for Lab-On-Chip applications at lower fluence. • Addition of Benzophenone in PDMS enhances its self development sensitivity. • Benzophenone helps efficient energy transfer for equal density of bond scissioning. • Correlation of chemical composition with laser dose and microstructure. • Microstructures with well defined clean sidewalls. - Abstract: This paper discusses microfabrication process for benzophenone doped polydimethylsiloxane (PDMS) using laser lithography. KrF excimer laser of 248 nm with 20 ns pulse width at repetition rate of 1 Hz was used for microfabrication of undoped and benzophenone doped PDMS. The doped-PDMS shows sensitivity below 365 nm, permitting processing under ambient light. The analysis of etch depth revealed that doped PDMS shows self developable sensitivity at lower fluence of ∼250 mJ/cm{sup 2}. The unexposed and exposed surface was studied using Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and Scanning electron microscopy (SEM). Spectrocopic analysis indicated increase in C-O, C=O, Si-O{sub 3} and Si-O{sub 4} bonding at the expense of Si-C and Si-O{sub 2} bonds of PDMS. In case of laser exposed doped-PDMS, removal of benzophenone from probe depth of spectroscopy was observed. Whereas the surface morphology of exposed and unexposed doped-PDMS was observed to be same, indicating clean development of PDMS micropatterns. The present study indicates that addition of 3.0 wt.% benzophenone in PDMS enhance self development sensitivity of PDMS. The self developable results on doped-PDMS are quite encouraging for its potential use in point of care Lab-On-Chip applications, for fabricating micropatterns using direct write laser lithography technology.

  20. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio [Montevergine Clinic, Mercogliano (Italy); Golino, Luca, E-mail: lucagolino.jazz@alice.it [Montevergine Clinic, Mercogliano (Italy); Moriggia-Pelascini Hospital, Gravedona, Como (Italy); Casafina, Alfredo; Schiano, Vittorio [Montevergine Clinic, Mercogliano (Italy); Gabrielli, Gabriele [University Hospital Ospedali Riuniti, Ancona (Italy); Ettori, Federica; Chizzola, Giuliano [Spedali Civili University Hospital, Brescia (Italy); Bernardi, Guglielmo; Spedicato, Leonardo [University Hospital S. Maria Misericordia, Udine (Italy); Armigliato, Pietro [Istituto Italiano Ricerche Mediche, Verona (Italy); Spampanato, Carmine [Telethon Institute of Genetics and Medicine (TIGEM), Naples (Italy); Furegato, Martina [Istituto Italiano Ricerche Mediche, Verona (Italy)

    2015-04-15

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  1. Measurement of radiation and temperature of cathod spots in excimer laser discharge; Ekishima reza reiki hodennai ni fukumareru inkyoku kiten no kogakuteki kansoku to ondo no sokutei

    Energy Technology Data Exchange (ETDEWEB)

    Minamitani, Y.; Nakatani, H. [Mitsubishi Electric Corp., Tokyo (Japan)

    1996-08-20

    Excimer laser is used in various fields such as luminous source for steppers, annealing treatment, ablation process, nuclear fusion and so on. In this paper, the radiation timing and gas temperature of cathode spots, streamer discharges and glow discharges in KrF excimer are measured by observing the radiating spectra thereof. The following conclusions are obtained from the results of the present study. Cathode spots begin to radiate at about 20ns after the discharge initiation, then the first and second radiation peaks are observed respectively when the discharge current reversing after passing zero point and the reserved discharged current approaching zero point. Streamer discharge makes flashover between electrodes at the second radiation peak of cathode spots, while the glow discharges almost disappear when streamer discharges occurring. The temperatures of cathode spots and glow discharge as 5500K and 2600K respectively are almost constant and independent upon the discharging voltage of laser. 14 refs., 12 figs.

  2. Multifocal Corneal Excimer Femtosecond Laser in situ Keratomileusis following Radial Keratotomy: A Case Report with Six Months of Follow-Up

    Directory of Open Access Journals (Sweden)

    Iraklis Vastardis

    2014-12-01

    Full Text Available We report the case of a 46-year-old female patient who was referred to our clinic (Orasis Eye Clinic, Reinach, Switzerland seeking improvement of her distance and near visual acuity. Radial keratotomy (RK was performed at a younger age on both eyes to correct -5 D myopia. The patient underwent a bilateral same-session multifocal corneal excimer femtosecond laser (Supracor keratomileusis correction. We introduce a new correction approach, possibly suitable for presbyopic patients previously treated with RK, and we present several potential novel advantages such as enhanced near, intermediate vision, and improvement in quality of life. This is the first report of a bilateral excimer laser treatment attempt of presbyopia following RK.

  3. Chaînes laser intenses à contraste élevé par amplification directe dans un milieu gazeux à excimères*

    Science.gov (United States)

    Uteza, O.; Tcheremiskine, V.; Clady, R.; Coustillier, G.; Gastaud, M.; Sentis, M.; Mikheev, L. D.; Chambaret, J. P.

    2006-12-01

    Cet article présente l'intérêt du concept de laser hybride (solide/gaz) et de l'amplification directe de puissance dans un milieu à excimères pour les chaînes laser de puissance ultrabrèves à contraste élevé. L'architecture d'une chaîne laser multiterawatt basée sur l'emploi du milieu amplificateur XeF(C-A) pompé par voie photolytique est ensuite détaillée, ainsi que les perspectives de dimensionnement de cette approche au niveau PWetEW.

  4. Morphological and structural modifications induced in a-Si{sub 1-x} C{sub x}:H films by excimer laser annealing

    Energy Technology Data Exchange (ETDEWEB)

    Coscia, U. [CNISM Unita' di Napoli, Complesso Universitario MSA, Napoli (Italy); Universita di Napoli ' Federico II' , Dipartimento di Scienze Fisiche, Napoli (Italy); Ambrosone, G. [Universita di Napoli ' Federico II' , Dipartimento di Scienze Fisiche, Napoli (Italy); CNR-SPIN, Napoli (Italy); Basa, D.K. [Utkal University, Department of Physics, Bhubaneswar (India); Tresso, E. [Politecnico di Torino, Dipartimento di Scienza dei Materiali ed Ingegneria Chimica, Turin (Italy); Chiodoni, A. [IIT rate at POLITO - Center for Space Human Robotics, Turin (Italy); Pinto, N.; Murri, R. [Universita' di Camerino, Dipartimento di Fisica, Camerino (Italy)

    2010-09-15

    Hydrogenated amorphous silicon carbon films of different carbon content deposited by plasma enhanced chemical vapour deposition on Corning glass and crystalline silicon substrates have been irradiated by an excimer (KrF) laser. The properties of these samples were investigated by X-ray diffraction, field emission scanning electron microscopy and Fourier transform infrared spectroscopy before and after laser treatment, in order to understand the role of the carbon content as well as the substrate in the structural modifications. It has been demonstrated that the changes induced in the films by the laser treatment are independent of the substrate but depend on the carbon content which facilitates the crystallization process. (orig.)

  5. INDEPENDENT EVALUATION OF THE GAM EX5ALN MINIATURE LINE-NARROWED KRF EXCIMER LASER

    Science.gov (United States)

    2017-06-01

    Bookmark not defined. 2: Ex5ALN KrF laser wavelength study. The laser output was recorded at 248.7 nm relative to the Hg atomic emission at 253.7 nm...Error! Bookmark not defined. 3: Ex5ALN KrF laser pulse width versus accumulated pulses for 14 kV discharge at 100 Hz...Error! Bookmark not defined. 4: Ex5ALN KrF laser timing jitter of laser

  6. Numerical study of threshold intensity dependence on gas pressure in the breakdown of molecular hydrogen induced by excimer laser

    Science.gov (United States)

    Gamal, Yosr E. E.-D.; Nassef, O. Aied

    2017-10-01

    In the present work, a numerical analysis is performed to investigate the threshold intensity dependence on gas pressure in laser spark ignition of the H2 plasma. The analysis considered the experimental measurements that were carried out by Yagi and Huo [Appl. Opt. 35, 3183 (1996)]. In their experiment, H2 in a pressure range of 150-3000 Torr is irradiated by a focused excimer laser source using a 96 cm lens at a wavelength of 248 nm and a pulse duration of 20 ns. The study, based on a modified electron cascade model [K. A. Hamam et al., J. Mod. Phys. 4, 311 (2013)], solves numerically a time-dependent energy equation for the distribution of the electron energy as well as a set of rate equations that describe the change in the formed excited molecule population. This model enabled the determination of the threshold intensity as a function of gas pressure. The validity of the model was tested by comparing the calculated thresholds with the experimentally measured ones. Moreover, the calculation of the electron energy distribution function and its parameters justified the role of the electron gain and loss processes in controlling the value of threshold intensity in relation to the gas pressure. The effect of loss processes on the threshold intensity is also presented.

  7. NC-controlled production of smooth 3D surfaces in brittle materials with 193-nm excimer laser

    Science.gov (United States)

    Toenshoff, Hans K.; Graumann, Christoph; Hesener, Hanno; Rinke, Marcus

    1998-08-01

    Micromachining performed by Excimer Lasers in conjunction with NC-controlled machines offer flexible production possibilities for 3-D-surfaces. Due to the limitations of conventional micromachining technology for brittle transparent materials in the micro range, a new laser machining beam guiding and data handling system was designed and built. The data handling starts with the mathematical description of the surface shape to be machined. The contour can be derived from a mathematical function or individual xyz-data point information from any CAD-program. A pre-processor calculates the nc-data for laser triggering, xyz-motion and the nc-mask control. Each laser pulse leads to a material removal, defined by the illuminated surface on the work piece as well as the energy density. The principal of superposition of pulses allows the creation of the desired contour. The chosen ablation strategy determines the surface roughness and the process speed. To achieve best results, it has to be carefully adjusted for a specific material. This technique does not require prefabricated tools such as semiconductor masks. This is a sufficient method for structuring grooves in ceramics, diamonds or glass as well as aspherical transparent optical surfaces or micro lens arrays. The excellent absorption of 193 nm compared to 248 nm or larger wavelengths leads to damage free structuring of most brittle materials. The optimized surface ablation process requires spot sizes and energy densities on the work piece which can not be realized with a mirror based beam guidance system. To eliminate these restrictions, a new mirror free machining concept with a gas flushed beam guiding system mounted on a granite vibration reduction table with air bearing positioning system was build. This paper describes the potential of 193 nm treatment of 3-D micro surfaces with a process optimized machine and data handling system.

  8. Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes

    Energy Technology Data Exchange (ETDEWEB)

    Keates, R.H.; Bloom, R.T.; Schneider, R.T.; Ren, Q.; Sohl, J.; Viscardi, J.J. (Univ. of California, Irvine (USA))

    1990-11-01

    Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by a factor of 10 after traveling the first 5.5 mm. However, we observed that the material in the eye fluoresces, meaning the 308 nm is transformed into other (longer) wavelengths that travel through the total eye with minimal absorption. Conclusions drawn from this experiment are that the use of the 308-nm wavelength may have undesirable side effects, while the use of the 193-nm wavelength should be consistent with ophthalmic use on both the cornea and the lens.

  9. LASEK for the correction of hyperopia with mitomycin C using SCHWIND AMARIS excimer laser: one-year follow-up

    Directory of Open Access Journals (Sweden)

    Khosrow Jadidi

    2015-11-01

    Full Text Available AIM: To evaluate the efficacy, safety and predictability of laser-assisted sub-epithelial keratectomy(LASEKfor the correction of hyperopia using the SCHWIND AMARIS platform.METHODS: This retrospective single-surgeon study includes 66 eyes of 33 patients with hyperopia who underwent LASEK with mitomycin C(MMC. The median age of patients was 35.42±1.12y(ranging 18 to 56y. In each patient LASEK was performed using SCHWIND AMARIS excimer laser. Postoperatively clinical outcomes were evaluated in terms of predictability, safety, efficacy, subjective and objective refractions, uncorrected visual acuity(UCVA, best spectacle-corrected visual acuity(BSCVAand adverse events. RESULTS: The mean baseline refraction was 3.2±1.6 diopters(D(ranging 0 to 7 D. The mean pre-operative and postoperative spherical equivalent(SEwere 2.34±1.76(ranging -1.25 to 7 Dand 0.30±0.84(ranging -0.2 to 0.8 Drespectively(P=0.001. The mean hyperopia was 0.63±0.84 D(ranging -1.75 to 2.76 D6 to 12mo postoperatively. Likewise, the mean astigmatism was 0.68±0.43 D(range 0 to 2 Dwith 51(77.3%and 15(22.7%eyes within ±1 and ±0.50 D respectively. The safety index and efficacy index were 1.08 and 1.6 respectively.CONCLUSION:LASEK using SCHWIND AMARIS with MMC yields good visual and refractive results for hyperopia. Moreover, there were no serious complications.

  10. Chitosan- and polypropylene-oriented surface modification using excimer laser and their biocompatibility study.

    Science.gov (United States)

    Khaledian, Mohammad; Jiroudhashemi, Faeze; Biazar, Esmaeil

    2017-02-01

    Surface modification of medical polymers is carried out to improve biocompatibility. In this study, conventional polymers (chitosan and polypropylene) were modified to laser at different features (oriented and non-oriented) to create a vast range of physicochemical characteristics on the surface of polymers and investigate their effects on biocompatibility of treated surfaces. Atomic force microscope (AFM) was applied to study the morphology of treated samples in comparison with those of the untreated PS. Contact angle analyses were used to evaluate the wettability and surface energy of the treated films. AFM studies showed that after laser treatment, some distinctive nanostructures are created on the surface of polymers. The data from contact angle measurements demonstrated that laser irradiation created surfaces with a vast range of properties in the wettability point of view. The cellular results revealed that after surface modification by laser irradiation, biocompatibility of polymeric films, especially oriented films was enhanced.

  11. H and Au diffusion in high mobility a-InGaZnO thin-film transistors via low temperature KrF excimer laser annealing

    Science.gov (United States)

    Bermundo, Juan Paolo S.; Ishikawa, Yasuaki; Fujii, Mami N.; Ikenoue, Hiroshi; Uraoka, Yukiharu

    2017-03-01

    We report the fabrication of high mobility amorphous InGaZnO (a-IGZO) thin-film transistors (TFTs) irradiated by a single shot of a 248 nm KrF excimer laser. Very high mobilities (μ) of up to 43.5 cm2/V s were obtained after the low temperature excimer laser annealing (ELA) process. ELA induces high temperatures primarily in the upper layers and maintains very low temperatures of less than 50 °C in the substrate region. Scanning Transmission Electron micrographs show no laser induced damage and clear interfaces after the laser irradiation. In addition, several characterization studies were performed to determine the μ improvement mechanism. The analysis of Secondary Ion Mass Spectrometry and X-ray Photoelectron Spectroscopy suggests incorporation of H mainly from the hybrid passivation layer into the channel. Moreover, Energy-dispersive X-ray Spectroscopy results show that Au diffused into the channel after ELA. Both KrF ELA-induced H and Au diffusion contributed to the higher μ. These results demonstrate that ELA can greatly enhance the electrical properties of a-IGZO TFTs for promising applications in large area, transparent, and flexible electronics.

  12. Mitomycin-C in corneal surface excimer laser ablation techniques: a report by the American Academy of Ophthalmology.

    Science.gov (United States)

    Majmudar, Parag A; Schallhorn, Steven C; Cason, John B; Donaldson, Kendall E; Kymionis, George D; Shtein, Roni M; Verity, Steven M; Farjo, Ayad A

    2015-06-01

    To review the published literature assessing the efficacy and safety of mitomycin-C (MMC) as an adjunctive treatment in corneal surface excimer laser ablation procedures. Literature searches of the PubMed and Cochrane Library databases were last conducted on August 19, 2014, without language or date limitations. The searches retrieved a total of 239 references. Of these, members of the Ophthalmic Technology Assessment Committee Refractive Management/Intervention Panel selected 26 articles that were considered to be of high or medium clinical relevance, and the panel methodologist rated each article according to the strength of evidence. Ten studies were rated as level I evidence, 5 studies were rated as level II evidence, and the remaining 11 studies were rated as level III evidence. The majority of the articles surveyed in this report support the role of MMC as an adjunctive treatment in surface ablation procedures. When MMC is applied in the appropriate concentration and confined to the central cornea, the incidence of post-surface ablation haze is decreased. Although a minority of studies that evaluated endothelial cell density (ECD) reported an MMC-related decrease in ECD, no clinical adverse outcomes were reported. Over the past 15 years, the use of MMC during surgery in surface ablation has become widespread. There is good evidence of the effectiveness of MMC when used intraoperatively as prophylaxis against haze in higher myopic ablations. Although there are reports of decreased endothelial counts after the administration of MMC during surgery, the clinical significance of this finding remains uncertain, because no adverse outcomes were reported with as much as 5 years of follow-up. Optimal dosage, effectiveness as prophylaxis in lower myopic and hyperopic ablations, and long-term safety, particularly in eyes with reduced corneal endothelial cell counts from prior intraocular surgery, have yet to be established. Copyright © 2015 American Academy of

  13. Laser in situ keratomileusis with a scanning excimer laser for the correction of low to moderate myopia with and without astigmatism.

    Science.gov (United States)

    Balazsi, G; Mullie, M; Lasswell, L; Lee, P A; Duh, Y J

    2001-12-01

    To evaluate the safety and effectiveness of and patient satisfaction with laser in situ keratomileusis (LASIK) performed with a scanning excimer laser by experienced surgeons to correct low and moderate levels of myopia and astigmatism. Clinique Laservue, Montreal, Quebec, Canada. A consecutive series of 125 patients (236 eyes) with myopia of -0.5 to -7.0 diopters (D) and cylinder less than 2.5 D were enrolled in this single-center prospective clinical trial. The patients were treated with LASIK and followed for 6 months. The System-ALK Automated Corneal Shaper microkeratome (Bausch & Lomb Surgical) with a 180 microm thickness plate and the Technolas 217 excimer laser (Bausch & Lomb Surgical) with PlanoScan software for the stromal ablation were used in all procedures. Since this version of PlanoScan tended to undercorrect, a mean of 14.7% was added to the standard nomogram. Patient satisfaction was assessed by questionnaires administered preoperatively and 1 and 6 months postoperatively. Retreatments for enhancement were not performed during the 6-month follow-up. Six months after LASIK (86.4% follow-up), the mean postoperative manifest spherical equivalent was +0.02 D +/- 0.64 (SD) compared with a preoperative mean of -4.01 +/- 1.59 D. The uncorrected visual acuity was 20/40 or better in 94.6% of eyes and 20/20 or better in 81.9%. A total of 91.2% were within +/-1.0 D of emmetropia and 73.0% were within +/-0.5 D. Only 2 eyes were overcorrected by >1.0 D. Of the eyes with astigmatic myopia, 86.8% were within +/-1.0 D of the intended cylinder correction (by vector analysis) and 73.0% were within +/-0.5 D. The refractions were generally stable after 1 month, and the change in refraction between postoperative examinations was within +/-0.5 D in 88.0% of eyes. A 1-line decrease in best spectacle-corrected visual acuity was seen in 11.3% of eyes, and no eye lost more than 1 line. An increase of 1 or 2 lines was seen in 45.1%. No intraoperative problems occurred, and

  14. Biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery: is there a difference between advanced surface ablation and sub-Bowman's keratomileusis?

    Science.gov (United States)

    Dawson, Daniel G; Grossniklaus, Hans E; McCarey, Bernard E; Edelhauser, Henry F

    2008-01-01

    To describe the biomechanical and wound healing characteristics of corneas after excimer laser keratorefractive surgery. Histologic, ultrastructural, and cohesive tensile strength evaluations were performed on 25 normal human corneal specimens, 206 uncomplicated LASIK specimens, 17 uncomplicated sub-Bowman's keratomileusis (SBK) specimens, 4 uncomplicated photorefractive keratectomy (PRK) specimens, 2 uncomplicated advanced surface ablation (ASA) specimens, 5 keratoconus specimens, 12 postoperative LASIK ectasia specimens, and 1 postoperative PRK ectasia specimen and compared to previously published studies. Histologic and ultrastructural studies of normal corneas showed significant differences in the direction of collagen fibrils and/or the degree of lamellar interweaving in Bowman's layer, the anterior third of the corneal stroma, the posterior two-thirds of the corneal stroma, and Descemet's membrane. Cohesive tensile strength testing directly supported these morphologic findings as the stronger, more rigid regions of the cornea were located anteriorly and peripherally. This suggests that PRK and ASA, and secondarily SBK, should be biomechanically safer than conventional LASIK with regard to risk for causing keratectasia after surgery. Because adult human corneal stromal wounds heal slowly and incompletely, all excimer laser keratorefractive surgical techniques still have some distinct disadvantages due to inadequate reparative wound healing. Despite reducing some of the risk for corneal haze compared to conventional PRK, ASA cases still can develop corneal haze or breakthrough haze from the hypercellular fibrotic stromal scarring. In contrast, similar to conventional LASIK, SBK still has the short- and long-term potential for interface wound complications from the hypocellular primitive stromal scar. Ophthalmic pathology and basic science research show that SBK and ASA are improvements in excimer laser keratorefractive surgery compared to conventional LASIK or

  15. Photosensitivity and stress changes of Ge-free Bi-Al doped silica optical fibers under ArF excimer laser irradiation.

    Science.gov (United States)

    Ban, Christian; Limberger, Hans G; Mashinsky, Valery; Dianov, Evgeny

    2011-12-19

    The photosensitivity of germanium free Bi-Al-doped silica fibers with different bismuth concentrations was investigated using ArF excimer laser radiation at 193 nm and fiber grating formation. For the fiber with the highest bismuth concentration maximum refractive index changes of 2.2 × 10(-3) and 2.0 × 10(-4) were obtained for hydrogen loaded and unloaded fibers, respectively. Irradiation induced tensile stress changes were observed in the fiber core of H(2)-loaded and unloaded fibers. The results indicate a contribution of compaction to the total refractive index change in both cases.

  16. Surface modification of an Al2O3/SiO2 based ceramic treated with CO2, Nd:YAG, excimer and high power diode lasers for altered wettability characteristics

    OpenAIRE

    Lawrence, Jonathan; Li, Lin; Spencer, Julian T.

    1998-01-01

    Interaction of CO2, Nd:YAG, excimer and high power diode laser (HPDL) radiation with the surface of an Al2O3/SiO2 based ceramic was found to affect significant changes in the wettability characteristics of the material. It was observed that interaction with CO2, Nd:YAG and HPDL radiation reduced the enamel contact angle from 1180 to 310, 340 and 330 respectively. In contrast, interaction with excimer laser radiation resulted an increase in the contact angle to 1210. Such changes were identifi...

  17. Comparison of boron diffusion in silicon during shallow p{sup +}/n junction formation by non-melt excimer and green laser annealing

    Energy Technology Data Exchange (ETDEWEB)

    Aid, Siti Rahmah; Matsumoto, Satoru [Department of Electronics and Electrical Engineering, Keio University, 3-14-1 Hiyoshi, Kouhoku-ku, Yokohama, Kanagawa 223-8522 (Japan); Fuse, Genshu [SEN Corporation, SBS Tower 9F, 4-10-1 Yoga, Setagaya-ku, Tokyo 158-0097 (Japan); Sakuragi, Susumu [Sumitomo Heavy Industries Ltd., 19 Natsushima-cho, Yokosuka, Kanagawa 237-8555 (Japan)

    2011-12-15

    The combination of Ge pre-amorphization implantation, low-energy boron implantation, and non-melt laser annealing is a promising method for forming ultrashallow p{sup +}/n junctions in silicon. In this study, shallow p{sup +}/n junctions were formed by non-melt annealing implanted samples using a green laser (visible laser). The dopant diffusion, activation, and recrystallization of an amorphous silicon layer were compared with those obtained in our previous study in which non-melt annealing was performed using a KrF excimer laser (UV laser). The experimental results reveal that only slight diffusion of boron in the tail region occurred in green-laser-annealed samples. In contrast, remarkable boron diffusion occurred in KrF-laser-annealed samples for very short annealing times. Recrystallization of the amorphous silicon layer was slower in green-laser-annealed samples than in KrF-laser-annealed samples. We consider the penetration depth and the pulse duration are important factors that may affect boron diffusion. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Some optical and electron microscope comparative studies of excimer laser-assisted and nonassisted molecular-beam epitaxically grown thin GaAs films on Si

    Science.gov (United States)

    Lao, Pudong; Tang, Wade C.; Rajkumar, K. C.; Guha, S.; Madhukar, A.; Liu, J. K.; Grunthaner, F. J.

    1990-01-01

    The quality of GaAs thin films grown via MBE under pulsed excimer laser irradiation on Si substrates is examined in both laser-irradiated and nonirradiated areas using Raman scattering, Rayleigh scattering, and by photoluminescence (PL), as a function of temperature, and by TEM. The temperature dependence of the PL and Raman peak positions indicates the presence of compressive stress in the thin GaAs films in both laser-irradiated and nonirradiated areas. This indicates incomplete homogeneous strain relaxation by dislocations at the growth temperature. The residual compressive strain at the growth temperature is large enough such that even with the introduction of tensile strain arising from the difference in thermal expansion coefficients of GaAs and Si, a compressive strain is still present at room temperature for these thin GaAs/Si films.

  19. Fabrication of functional fibronectin patterns by nanosecond excimer laser direct write for tissue engineering applications.

    Science.gov (United States)

    Grigorescu, S; Hindié, M; Axente, E; Carreiras, F; Anselme, K; Werckmann, J; Mihailescu, I N; Gallet, O

    2013-07-01

    Laser direct write techniques represent a prospective alternative for engineering a new generation of hybrid biomaterials via the creation of patterns consisting of biological proteins onto practically any type of substrate. In this paper we report on the characterization of fibronectin features obtained onto titanium substrates by UV nanosecond laser transfer. Fourier-transform infrared spectroscopy measurements evidenced no modification in the secondary structure of the post-transferred protein. The molecular weight of the transferred protein was identical to the initial fibronectin, no fragment bands being found in the transferred protein's Western blot migration profile. The presence of the cell-binding domain sequence and the mannose groups within the transferred molecules was revealed by anti-fibronectin monoclonal antibody immunolabelling and FITC-Concanavalin-A staining, respectively. The in vitro tests performed with MC3T3-E1 osteoblast-like cells and Swiss-3T3 fibroblasts showed that the cells' morphology and spreading were strongly influenced by the presence of the fibronectin spots.

  20. High-efficient discharge-pumped ArF (193 nm) excimer laser with a TPI thyratron as a high-voltage switch

    Science.gov (United States)

    Razhev, Alexander M.; Zhupikov, Andrey A.; Churkin, Dmitry S.

    2007-06-01

    The results of using the thyratron of the TPI series (pseudo spark gap) as a high-voltage switch in the excitation system of ArF (193 nm) excimer laser are presented. The excitation system of the LC-inverter type based on TPI 10k/20 thyratron in absence of any non-linear elements was developed. An experimental investigation of the energy and temporal parameters of the pumping and lasing for ArF laser on the He:Ar:F II mixture with excitation system developed was carried out. The comparative analysis of the ArF laser pumping and radiation parameters in dependence of the high-voltage switch type such as a standard spark gap RU-65, and thyratron TPI 10k/20 was performed. The output radiation energy for a laser with thyratron TPI 10k/20 was obtained to be of 1.4 times higher than that with standard spark gap RU-65 at the same pumping conditions. Such increase the output energy was shown to be achieving owing to higher level of the pumping intensity due to higher voltage on the discharge gap that occurs due to lower energy losses into TPI thyratron in comparison with the RU- 65 spark gap and leads to more efficient energy transfer from storage to discharge circuit. As a result for ArF laser with TPI thyratron in He:Ar:F II mixture the output radiation energy of 1.0 J with the total efficiency of 1.7% has been achieved. The advantages of using the TPI thyratron in the excitation system of the ArF excimer laser over spark gap are described.

  1. FEM for modelling 193 nm excimer laser treatment of SiO{sub 2}/Si/Si{sub (1-x)}Ge{sub x} heterostructures on SOI substrates

    Energy Technology Data Exchange (ETDEWEB)

    Conde, J.C.; Chiussi, S.; Gontad, F.; Gonzalez, P. [Dpto. Fisica Aplicada, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, 36310 Vigo (Spain); Martin, E. [Dpto. de Mecanica, Maquinas, Motores Termicos y Fluidos, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, 36310 Vigo (Spain)

    2011-03-15

    Research on epitaxial crystalline silicon (c-Si) and silicon-germanium (Si{sub 1-x}Ge{sub x}) alloys growth and annealing for microelectronic purposes, such as Micro- or Nano-Electro-Mechanical Systems (MEMS or NEMS) and Silicon-On-Nothing (SON) devices is continuously in progress. Laser assisted annealing techniques using commercial ArF Excimer Laser sources are based on ultra-rapid heating and cooling cycles induced by the 193 nm pulses of 20 ns, which are absorbed in the near surface region of the heterostructures. During and after the absorption of these laser pulses, complex physical processes appear that strongly depend on sample structure and applied laser pulse energy densities. The control of the experimental parameters is therefore a key task for obtaining high quality alloys. The Finite ElementsMethod (FEM) is a powerful tool for the optimization of such treatments, because it provides the spatial and temporal temperature fields that are produced by the laser pulses. In this work, we have used a FEM commercial software, to predict the temperatures gradients induced by ArF excimer laser over a wide energy densities range, 0.1<{phi}<0.4 J/cm{sup 2}, on different SiO{sub 2}/Si/Si{sub (1-x)}Ge{sub (x)} thin films deposited on SOI substrate. These numerical results allow us to predict the threshold energies needed to reach the melting point (MP) of the Si and SiGe alloy without oxidation of the thin films system. Therefore, it is possible to optimize the conditions to achieve high quality epitaxy films. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. XeCl excimer laser-induced autofluorescence spectroscopy for human cerebral tumor diagnosis: preliminary study

    Science.gov (United States)

    Avrillier, Sigrid; Hor, Frederic; Desgeorges, Michel; Ettori, Dominique; Sitbon, Jean R.

    1993-09-01

    Three-hundred-eight nm laser-induced autofluorescence spectra of the normal human brain, astrocytoma grade IV and glioblastoma grade IV specimens, have been recorded in vitro two hours after surgical resection. Typical fluorescence spectra for normal (N) and malignant (M) tissue show 4 maxima at about 352, 362, 383, and 460 nm. These spectra are analyzed in detail. Subtle differences in normalized spectra of N and M tissues appear to be large enough for diagnosis. Several criteria such as maxima and minima absolute intensity and intensity ratios at typical wavelengths are computed and used to classify the tissue. This preliminary study shows that fluorescence spectroscopy with 308 nm UV excitation could be a valid technique for discriminating tumor types. However, it should be noted that these measurements are made in vitro. Living tissues may have different spectral characteristics, therefore future in vivo investigations must be performed.

  3. Low temperature high-mobility InZnO thin-film transistors fabricated by excimer laser annealing

    NARCIS (Netherlands)

    Fujii, M.; Ishikawa, Y.; Ishihara, R.; Van der Cingel, J.; Mofrad, M.R.T.; Horita, M.; Uraoka, Y.

    In this study, we successfully achieved a relatively high field-effect mobility of 37.7?cm2/Vs in an InZnO thin-film transistor (TFT) fabricated by excimer layer annealing (ELA). The ELA process allowed us to fabricate such a high-performance InZnO TFT at the substrate temperature less than 50?°C

  4. Low temperature high-mobility InZnO thin-film transistors fabricated by excimer laser annealing

    NARCIS (Netherlands)

    Fujii, M.; Ishikawa, Y.; Ishihara, R.; Van der Cingel, J.; Mofrad, M.R.T.; Horita, M.; Uraoka, Y.

    2013-01-01

    In this study, we successfully achieved a relatively high field-effect mobility of 37.7?cm2/Vs in an InZnO thin-film transistor (TFT) fabricated by excimer layer annealing (ELA). The ELA process allowed us to fabricate such a high-performance InZnO TFT at the substrate temperature less than 50?°C

  5. Effects of closed immersion filtered water flow velocity on the ablation threshold of bisphenol A polycarbonate during excimer laser machining

    Energy Technology Data Exchange (ETDEWEB)

    Dowding, Colin, E-mail: c.f.dowding@lboro.ac.uk [Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom); Lawrence, Jonathan [Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom)

    2010-04-01

    A closed flowing thick film filtered water immersion technique ensures a controlled geometry for both the optical interfaces of the flowing liquid film and allows repeatable control of flow-rate during machining. This has the action of preventing splashing, ensures repeatable machining conditions and allows control of liquid flow velocity. To investigate the impact of this technique on ablation threshold, bisphenol A polycarbonate samples have been machined using KrF excimer laser radiation passing through a medium of filtered water flowing at a number of flow velocities, that are controllable by modifying the liquid flow-rates. An average decrease in ablation threshold of 7.5% when using turbulent flow velocity regime closed thick film filtered water immersed ablation, compared to ablation using a similar beam in ambient air; however, the use of laminar flow velocities resulted in negligible differences between closed flowing thick film filtered water immersion and ambient air. Plotting the recorded threshold fluence achieved with varying flow velocity showed that an optimum flow velocity of 3.00 m/s existed which yielded a minimum ablation threshold of 112 mJ/cm{sup 2}. This is attributed to the distortion of the ablation plume effected by the flowing immersion fluid changing the ablation mechanism: at laminar flow velocities Bremsstrahlung attenuation decreases etch rate, at excessive flow velocities the plume is completely destroyed, removing the effect of plume etching. Laminar flow velocity regime ablation is limited by slow removal of debris causing a non-linear etch rate over 'n' pulses which is a result of debris produced by one pulse remaining suspended over the feature for the next pulse. The impact of closed thick film filtered water immersed ablation is dependant upon beam fluence: high fluence beams achieved greater etch efficiency at high flow velocities as the effect of Bremsstrahlung attenuation is removed by the action of the fluid on

  6. Long-term efficacy of excimer laser in situ keratomileusis in the management of children with high anisometropic amblyopia.

    Science.gov (United States)

    Lin, Xiao-Ming; Yan, Xiao-He; Wang, Zheng; Yang, Bin; Chen, Qi-Wen; Su, Jin-Ai; Ye, Xue-Lian

    2009-04-05

    Children with anisometropic amblyopia are often noncompliant with traditional treatment including spectacules and contact lenses. This study was to evaluate the long-term efficacy of excimer laser in situ keratomileusis (LASIK) for children with high anisometropic amblyopia. A retrospective analysis of 24 children with high unilateral anisometropic amblyopia, who underwent LASIK during the period between August 2000 and September 2005 in our hospital, was conducted. The mean age of these children was (7.4 +/- 1.9) years (range 5 - 14 years) and the mean follow-up period was (33.3 +/- 14.2) months (range 18.5 - 74.2 months). After LASIK, visual acuity, refraction and far or near stereoacuity were analyzed. Near stereoacuity was measured by the random-dot butterfly stereogram and the pre-school random-dot stereogram, while far stereoacuity was measured by the synoptophore with Yan's random-dot stereogram. Mean preoperative uncorrected visual acuity was 0.06 +/- 0.05, while mean postoperative uncorrected visual acuity was elevated to 0.43 +/- 0.33. Mean preoperative best-corrected visual acuity was 0.26 +/- 0.22, while mean postoperative best-corrected visual acuity was elevated to 0.67 +/- 0.40. For patients with myopic anisometropia, preoperative mean spherical equivalent refraction was (-8.01 +/- 2.70) D while postoperative value significantly reduced to (-1.32 +/- 2.47) D. For patients with hyperopic anisometropia, preoperative mean spherical equivalent refraction was (+7.35 +/- 1.55) D while postoperative value significantly reduced to (+3.30 +/- 0.86) D. These results demonstrated that there was statistical difference in these parameters between preoperative and postoperative tests. At the last follow-up, 20 patients had near stereoacuity, and the mean near stereoacuities measured by the random-dot butterfly stereogram and the preschool random-dot stereogram were (149.00 +/- 152.93)'' and (201.05 +/- 235.94)'', respectively. In contrast, 11 patients had far

  7. Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.

    Directory of Open Access Journals (Sweden)

    Kaevalin Lekhanont

    Full Text Available The purpose of this study was to investigate the agreement between the clinical history method (CHM, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery. Fifty five patients who had myopic LASIK/PRK were recruited into this study. One eye of each patient was randomly selected by a computer-generated process. At 6 months after surgery, postoperative corneal power was calculated from the CHM, Orbscan IIz total optical power at the 3.0 and 4.0 mm zones, and Pentacam equivalent keratometric readings (EKRs at 3.0, 4.0, and 4.5 mm. Statistical analyses included multilevel models, Pearson's correlation test, and Bland-Altman plots. The Orbscan IIz 3.0-mm and 4.0 mm total optical power, and Pentacam 3.0-mm, 4.0-mm, and 4.5-mm EKR values had strong linear positive correlations with the CHM values (r = 0.90-0.94, P = <0.001, for all comparisons, Pearson's correlation. However, only Pentacam 3.0-mm EKR was not statistically different from CHM (P = 0.17, multilevel models. The mean 3.0- and 4.0-mm total optical powers of the Orbscan IIz were significantly flatter than the values derived from CHM, while the average EKRs of the Pentacam at 4.0 and 4.5 mm were significantly steeper. The mean Orbscan IIz 3.0-mm total optical power was the lowest keratometric reading compared to the other 5 values. Large 95% LoA was observed between each of these values, particularly EKRs, and those obtained with the CHM. The width of the 95% LoA was narrowest for Orbscan IIz 3.0-mm total optical power. In conclusion, the keratometric values extracted from these 3 methods were disparate, either because of a statistically significant difference in the mean values or moderate agreement between them. Therefore, they are not considered equivalent and cannot be used interchangeably.

  8. Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platform

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2012-06-01

    Full Text Available Anastasios John KanellopoulosDepartment of Ophthalmology, New York University Medical School, New York, NY, and LaserVision.gr Eye Institute, Athens, GreeceBackground: The purpose of this study was to evaluate the safety and efficacy of topography-guided ablation using the WaveLight 400 Hz excimer laser in laser-assisted in situ keratomileusis (LASIK for hyperopia and/or hyperopic astigmatism.Methods: We prospectively evaluated 208 consecutive LASIK cases for hyperopia with or without astigmatism using the topography-guided platform of the 400 Hz Eye-Q excimer system. The mean preoperative sphere value was +3.04 ± 1.75 (range 0.75–7.25 diopters (D and the mean cylinder value was –1.24 ± 1.41 (–4.75–0 D. Flaps were created either with Intralase FS60 (AMO, Irvine, CA or FS200 (Alcon, Fort Worth, TX femtosecond lasers. Parameters evaluated included age, preoperative and postoperative refractive error, uncorrected distance visual acuity, corrected distance visual acuity, flap diameter and thickness, topographic changes, higher order aberration changes, and low contrast sensitivity. These measurements were repeated postoperatively at regular intervals for at least 24 months.Results: Two hundred and two eyes were available for follow-up at 24 months. Uncorrected distance visual acuity improved from 5.5/10 to 9.2/10. At 24 (8–37 months, 75.5% of the eyes were in the ±0.50 D range and 94.4% were in the ±1.00 D range of the refractive goal. Postoperatively, the mean sphere value was –0.39 ± 0.3 and the cylinder value was –0.35 ± 0.25. Topographic evidence showed that ablation was made in the visual axis and not in the center of the cornea, thus correlating with the angle kappa. No significant complications were encountered in this small group of patients.Conclusion: Hyperopic LASIK utilizing the topography-guided platform of the 400 Hz Eye-Q Allegretto excimer and a femtosecond laser flap appears to be safe and effective for

  9. Formation of densely populated SiOx microtree-like structures on the Si (100) surface using excimer laser irradiation in air

    Science.gov (United States)

    Yang, De-Quan; Sacher, Edward; Meunier, Michel

    2004-10-01

    SiOx microforest-like structures have been produced on Si (100) surfaces by pulsed excimer laser irradiation in air. Scanning electron microscopic observations have indicated these structures, which are composed of aggregated nanoparticles, to be 1-5 μm in diameter and 10-20 μm high, and to have the appearance of trees. XPS analysis has shown them to be composed of a-SiOx (1laser irradiation, our microforest-like trees have many sharp nanoscale branches, which may require lower emission voltages in application such as field-emission sources in plasma displays.

  10. Fabrication of an integrated optical Mach-Zehnder interferometer based on refractive index modification of polymethylmethacrylate by krypton fluoride excimer laser radiation

    Science.gov (United States)

    Koerdt, Michael; Vollertsen, Frank

    2011-04-01

    It is known that deep ultraviolet (UV) radiation induces a refractive index increase in the surface layer of polymethylmethacrylate (PMMA) samples. This effect can be used for the fabrication of integrated optical waveguides. PMMA is of considerable interest for bio and chemical sensing applications because it is biocompatible and can be micromachined by several methods, e.g. structuring by photolithography, ablation and hot embossing. In the presented work direct UV irradiation of a common PMMA substrate by a krypton fluoride excimer laser beam through a contact mask has been used to write integrated optical Mach-Zehnder interferometers (MZI). MZI are used as sensitive bio and chemical sensors. The aim was to determine contact mask design and laser irradiation parameters for fabricating single-mode MZI for the infrared region from 1.30 μm to 1.62 μm. Straight and curved waveguides have been generated and characterized to determine the optical losses. The generation of channel waveguide structures has been optimized by a two step irradiation process to minimize the lithographic writing time and optical loss. By flood exposure to UV laser radiation in the first step the optical absorption of PMMA can be increased in the irradiated region. The required refractive index profile is then achieved with a second lithographic irradiation. The spectral behaviour of an unbalanced, integrated optical MZI fabricated by this excimer laser based contact mask method is shown for the first time. Further the optical intensity at the output port of a MZI has been measured while the optical path length difference was tuned by creating a temperature difference between the two arms of the MZI.

  11. Fabrication of an integrated optical Mach-Zehnder interferometer based on refractive index modification of polymethylmethacrylate by krypton fluoride excimer laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    Koerdt, Michael, E-mail: koerdt@bias.de [BIAS - Bremer Institut fuer angewandte Strahltechnik GmbH, Klagenfurter Strasse 2, D-28359 Bremen (Germany); Vollertsen, Frank [BIAS - Bremer Institut fuer angewandte Strahltechnik GmbH, Klagenfurter Strasse 2, D-28359 Bremen (Germany)

    2011-04-01

    It is known that deep ultraviolet (UV) radiation induces a refractive index increase in the surface layer of polymethylmethacrylate (PMMA) samples. This effect can be used for the fabrication of integrated optical waveguides. PMMA is of considerable interest for bio and chemical sensing applications because it is biocompatible and can be micromachined by several methods, e.g. structuring by photolithography, ablation and hot embossing. In the presented work direct UV irradiation of a common PMMA substrate by a krypton fluoride excimer laser beam through a contact mask has been used to write integrated optical Mach-Zehnder interferometers (MZI). MZI are used as sensitive bio and chemical sensors. The aim was to determine contact mask design and laser irradiation parameters for fabricating single-mode MZI for the infrared region from 1.30 {mu}m to 1.62 {mu}m. Straight and curved waveguides have been generated and characterized to determine the optical losses. The generation of channel waveguide structures has been optimized by a two step irradiation process to minimize the lithographic writing time and optical loss. By flood exposure to UV laser radiation in the first step the optical absorption of PMMA can be increased in the irradiated region. The required refractive index profile is then achieved with a second lithographic irradiation. The spectral behaviour of an unbalanced, integrated optical MZI fabricated by this excimer laser based contact mask method is shown for the first time. Further the optical intensity at the output port of a MZI has been measured while the optical path length difference was tuned by creating a temperature difference between the two arms of the MZI.

  12. Excimer Laser Research

    Science.gov (United States)

    1976-10-01

    ORGANIZATION N ATTETSTTF»UUHLJJ* Avco Everett Research Laboratory, Inc. 2385 Revere Beach Parkway Everett, Massachusetts 02149 REPORT...apparently enhanced by a large reactive c -oss section for producing excited species by chemica ’ reactions of the type Xe« I F,-XeF* • F. (1

  13. The applicability of the Sedov - Taylor scaling during material removal of metals and oxide layers with pulsed ? and excimer laser radiation

    Science.gov (United States)

    Aden, M.; Kreutz, E. W.; Schlüter, H.; Wissenbach, K.

    1997-03-01

    For the removal of material with pulsed laser radiation the distance travelled by the shock or blast wave and the amount of energy released in the plasma state due to the absorption of laser radiation are determined experimentally and theoretically. The distance travelled by the blast wave is detected by schlieren photography, the released energy by monitoring the transmitted laser radiation during the removal process. The theoretical evaluation is performed by numerical simulation using a model incorporating the laser-induced vaporization process and the dynamics of the plasma state. The results obtained from the experiments and the model are compared with that of the Sedov - Taylor scaling. The removal of the oxide layer from austenitic steel is investigated with 0022-3727/30/6/011/img8 laser radiation produced by a TEA and a high-power 0022-3727/30/6/011/img8 laser device. For the TEA laser with fluences of 5 and 10 J 0022-3727/30/6/011/img10 50 - 80% of the pulse energy is released into the plasma state and the Sedov - Taylor scaling describes the distance travelled by the blast wave in agreement with data from the experiments and the simulation. For the high-power 0022-3727/30/6/011/img8 laser with a fluence of 50 J 0022-3727/30/6/011/img10, 6% of the pulse energy is released into the plasma state and the Sedov - Taylor scaling does not describe the data of the simulation. The process of removal of copper and aluminium material is simulated for excimer laser radiation with fluences of 15 and 30 J 0022-3727/30/6/011/img10. For copper 15 - 30% of the pulse energy is released into the plasma state and the Sedov - Taylor scaling is applicable. For aluminium, less than 2% of the pulse energy is released into the plasma state and the Sedov - Taylor scaling is only applicable for the higher fluence.

  14. Assessment of expressions of heat shock protein (HSP 72) and apoptosis after ArF excimer laser ablation of the cornea.

    Science.gov (United States)

    Ishihara, Miya; Sato, Masato; Sato, Shunichi; Arai, Tsunenori; Obara, Minoru; Kikuchi, Makoto

    2004-01-01

    We immunohistochemically studied expressions of inducible heat shock protein 70 (HSP 72) and apoptosis of corneas ablated with an ArF excimer laser. The temperature of corneal surfaces and laser-induced optical emission spectra were measured in real time as direct physical parameters related to the ablation mechanism. To the best of the authors' knowledge, there have been no experimental studies regarding the influence of physical parameters directly related to the ablation mechanism on corneal reactions at the cell level after laser ablation. The expression of HSP 72 was mainly localized in the regenerative epithelium, which was confirmed to be caused by laser ablation. The HSP 72 positive cell ratios had a correlation with thermal dose, which was derived from the measured time courses of temperature. Expressions of both HSP 72 and apoptosis depended on the thermal dose and elapsed time after ablation. HSP 72 and apoptosis could be seen up to a few hundred micrometers into the stroma, only at a fluence with an optical breakdown emission. This could have been caused by shock waves induced by the optical breakdown. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

  15. O impacto da cirurgia de ceratectomia fotorrefrativa (PRK e ceratomileuse assistida por excimer laser in situ (LASIK na qualidade visual e de vida em pacientes com ametropias The impact of photorefractive excimer laser keratectomy (PRK and laser in situ keratomileusis (LASIK on visual quality and life in patients with ametropias

    Directory of Open Access Journals (Sweden)

    Ricardo Belfort

    2008-02-01

    Full Text Available OBJETIVO: Avaliar a qualidade de vida e de visão e o estresse de pacientes portadores de ametropias submetidos a procedimentos cirúrgicos. MÉTODOS: Estudo longitudinal observacional em que foram estudados 100 pacientes; 54 usuários de óculos, 21 usuários de lentes de contato interessados no procedimento cirúrgico e 25 controles usuários de óculos ou lentes de contato, mas que não desejavam ser operados no período de um ano. Os questionários aplicados foram o National Eye Institute Visual Function Questionnaire (NEI-VFQ-25 de qualidade de vida e o Self Reporting Questionnaire - SRQ-20 para avaliação da saúde mental. Os pacientes que se submeteram à cirurgia responderam aos questionários aplicados por uma observadora antes da mesma, três, seis e doze meses após a intervenção. O grupo controle respondeu de forma auto-aplicada no início do estudo, seis e doze meses após a primeira avaliação. RESULTADOS: No grupo da cirugia dos 54 pacientes que usavam óculos 39 fizeram cirurgia de ceratectomia fotorrefrativa por excimer laser(PRK e 15 fizeram ceratomileuse assistida por excimer laserin situ (LASIK e dos 21 que usavam lentes de contato 12 fizeram cirurgia de ceratectomia fotorrefrativa e nove fizeram ceratomileuse assistida por excimer laser in situ (LASIK. O grupo controle esteve estável durante os 12 meses em relação aos instrumentos aplicados. Três meses após a cirurgia o grupo da cirurgia apresentou melhora significante da qualidade de vida e de visão em relação ao pré-operatório independentemente do tipo de cirurgia realizada. Um ano após a cirurgia os índices de qualidade de vida e de saúde mental, foram semelhantes aos do grupo controle. O Self Reporting Questionnaire - SRQ 20 mostrou diminuição significante do índice de sintomas a partir dos três meses de pós-operatório. CONCLUSÃO: A qualidade de visão e de vida dos pacientes submetidos à cirurgia de correção de ametropia mudou

  16. EFFECT OF OPTICAL FIBER HYDROGEN LOADING ON THE INSCRIPTION EFFICIENCY OF CHIRPED BRAGG GRATINGS BY MEANS OF KrF EXCIMER LASER RADIATION

    Directory of Open Access Journals (Sweden)

    Sergey V. Varzhel

    2016-11-01

    Full Text Available Subject of Research.We present comparative results of the chirped Bragg gratings inscription efficiency in optical fiber of domestic production with and without low-temperature hydrogen loading. Method. Chirped fiber Bragg gratings inscription was made by the Talbot interferometer with chirped phase mask having a chirp rate of 2.3 nm/cm used for the laser beam amplitude separation. The excimer laser system Coherent COMPexPro 150T, working with the gas mixture KrF (248 nm, was used as the radiation source. In order to increase the UV photosensitivity, the optical fiber was placed in a chamber with hydrogen under a pressure of 10 MPa and kept there for 14 days at 40 °C. Main Results. The usage of the chirped phase mask in a Talbot interferometer scheme has made it possible to get a full width at half-maximum of the fiber Bragg grating reflection spectrum of 3.5 nm with induced diffraction structure length of 5 mm. By preliminary hydrogen loading of optical fiber the broad reflection spectrum fiber Bragg gratings with a reflectivity close to 100% has been inscribed. Practical Relevance. The resulting chirped fiber Bragg gratings can be used as dispersion compensators in optical fiber communications, as well as the reflective elements of distributed fiber-optic phase interferometric sensors.

  17. Experience in using the excimer laser-assisted nonocclusive anastomosis nonocclusive bypass technique for high-flow revascularization: Mannheim-Helsinki series of 64 patients.

    Science.gov (United States)

    Vajkoczy, Peter; Korja, Miikka; Czabanka, Marcus; Schneider, Ulf C; Reinert, Michael; Lehecka, Martin; Schmiedek, Peter; Hernesniemi, Juha; Kivipelto, Leena

    2012-01-01

    The excimer laser-assisted nonocclusive anastomosis (ELANA) technique enables large-caliber bypass revascularization without temporary occlusion of the parent artery. To present the surgical experience of 2 bypass centers using ELANA in the treatment of complex intracranial lesions. Between July 2002 and December 2007, 64 consecutive patients (37 in Germany and 27 in Finland) were selected for high-flow bypass surgery with ELANA. Modified Rankin Scale, a bypass success rate, and the success rate of the laser arteriotomy were assessed. In 66 surgeries for 64 intent-to-treat patients, 58 ELANA procedures were completed successfully. A favorable outcome (postoperative modified Rankin Scale score less than or equal to preoperative modified Rankin Scale) at 3 months was achieved in 43 of 56 patients (77%) with anterior circulation lesions (37 of the 43 patients had aneurysms, 4 had ischemia, and 2 received a bypass before tumor removal) and only in 2 of 8 patients (25%) with posterior circulation aneurysms. Perioperative (< 7 days) mortality for anterior and posterior circulation aneurysms was 6% and 50%, respectively. At the 3-month follow-up, 12% and 63% of patients with anterior and posterior circulation aneurysms, respectively, were dead. The success rate of the laser arteriotomy was 70%. Another 14% were retrieved manually after a nearly complete laser arteriotomy. The ELANA procedure requires a meticulous and careful operative technique. Morbidity and especially mortality rates, usually unrelated to ELANA, are comparable to those of contemporary series of conventional high-flow revascularization operations. This underscores the overall complexity of treating neurovascular pathologies by high-flow bypasses.

  18. Surface 3D Micro Free Forms: Multifunctional Microstructured Mesoporous α-Alumina by in Situ Slip Casting Using Excimer Laser Ablated Polycarbonate Molds.

    Science.gov (United States)

    Rowthu, Sriharitha; Böhlen, Karl; Bowen, Paul; Hoffmann, Patrik

    2015-11-11

    Ceramic surface microstructuring is a rapidly growing field with a variety of applications in tribology, wetting, biology, and so on. However, there are limitations to large-area microstructuring and fabrication of three-dimensional (3D) micro free forms. Here, we present a route to obtain intricate surface structures through in situ slip casting using polydimethylsiloxane (PDMS) negative molds which are replicated from excimer laser ablated polycarbonate (PC) master molds. PC sheets are ablated with a nanosecond KrF (λ = 248 nm) excimer laser mask projection system to obtain micron-scale 3D surface features over a large area of up to 3 m(2). Complex surface structures that include 3D free forms such as 3D topography of Switzerland, shallow structures such as diffractive optical elements (60 nm step) and conical micropillars have been obtained. The samples are defect-free produced with thicknesses of up to 10 mm and 120 mm diameter. The drying process of the slip cast alumina slurry takes place as a one-dimensional process, through surface evaporation and water permeation through the PDMS membrane. This allows homogeneous one-dimensional shrinkage during the drying process, independent of the sample's lateral dimensions. A linear mass diffusion model has been proposed to predict and explain the drying process of these ceramic colloidal suspensions. The calculated drying time is linearly proportional to the height of the slurry and the thickness of the negatively structured PDMS and is validated by the experimental results. An experimentally observed optimum Sylgard PDMS thickness range of ∼400 μm to 1 mm has achieved the best quality microstructured green compacts. Further, the model predicts that the drying time is independent of the microstructured areas and was validated using experimental observations carried out with microstructured areas of 300 mm(2), 1200 mm(2), and 120 cm(2). Therefore, in principle, the structures can be further replicated in areas up

  19. High-performance p-channel thin-film transistors with lightly doped n-type excimer-laser-crystallized germanium films

    Science.gov (United States)

    Liao, Chan-Yu; Huang, Ching-Yu; Huang, Ming-Hui; Huang, Wen-Hsien; Shen, Chang-Hong; Shieh, Jia-Min; Cheng, Huang-Chung

    2017-06-01

    High-performance polycrystalline-germanium (poly-Ge) thin-film transistors (TFTs) fabricated with lightly doped Ge thin films by excimer laser crystallization (ELC) and counter doping (CD) have been demonstrated. High-quality n-type Ge thin films with a grain size as large as 1 µm were fabricated by ELC in the super lateral-growth regime and CD at a dose of 1 × 1013 cm-2 or higher. Consequently, a superior field-effect mobility of 271 cm2 V-1 s-1 and a high on/off current ratio of 2.7 × 103 have been obtained for p-channel Ge TFTs with the channel width and length of both 0.5 µm fabricated by ELC at 300 mJ/cm2 and CD at a dose of 1 × 1013 cm-2. The effects of ELC conditions and CD dose on the electrical characteristics of p-channel Ge TFTs were also investigated.

  20. Surface analysis of the selective excimer laser patterning of a thin PEDOT:PSS film on flexible polymer films

    Science.gov (United States)

    Schaubroeck, David; De Smet, Jelle; Willems, Wouter; Cools, Pieter; De Geyter, Nathalie; Morent, Rino; De Smet, Herbert; Van Steenbeerge, Geert

    2016-07-01

    Fast patterning of highly conductive polymers like PEDOT:PSS (poly (3,4-ethylene dioxythiophene): polystyrene sulfonate) with lasers can contribute to the development of industrial production of liquid crystal displays on polymer foils. In this article, the selective UV laser patterning of a PEDOT:PSS film on flexible polymer films is investigated. Based on their optical properties, three polymer films are investigated: polyethylene terephthalate (PET), polymethyl methacrylate (PMMA) and cellulose triacetate (TAC). Ablation parameters for a 110 nm PEDOT:PSS film on these polymer films are optimized. A detailed study of the crater depth, topography and surface composition are provided using optical profilometry, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS), respectively. The electrical insulation of the lines is measured and correlated to the crater analyses for different laser settings. Finally, potential ablation parameters for each of the polymer films are derived.

  1. Review of the biocompatibility and blood compatibility properties of polyethersulfone film modified by the excimer and CO2 lasers

    Science.gov (United States)

    Pazokian, H.; Jelvani, S.; Mollabashi, M.; Barzin, J.

    2014-06-01

    In this paper the biocompatibility and blood compatibility changes of polyethersulfone (PES) films following laser irradiation at four different wavelengths of ArF (193 nm), KrF (248 nm), XeCl (308 nm) and CO2 (9.58 µm) lasers are studied. The surface behaviors in contact with platelets and fibroblasts cells are examined and the best irradiation parameters to improve the surface biocompatibility and blood compatibility were found. The biological modifications on the surface were explained by alteration of the surface morphology and chemistry following the irradiation. The results show that a KrF laser is the best choice for treatment of PES film in the biological applications.

  2. FEM numerical analysis of excimer laser induced modification in alternating multi-layers of amorphous and nano-crystalline silicon films

    Energy Technology Data Exchange (ETDEWEB)

    Conde, J.C., E-mail: jconde@uvigo.es [Dpto. Fisica Aplicada, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain); Martin, E. [Dpto. Mecanica, Maquinas, Motores Termicos y Fluidos, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain); Stefanov, S. [Dpto. Fisica Aplicada, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain); Alpuim, P. [Departamento de Fisica, Universidade do Minho, 4800-058 Guimaraes (Portugal); Chiussi, S. [Dpto. Fisica Aplicada, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer nc-Si:H is a material with growing importance for a large-area of nano-electronic, photovoltaic or biomedical devices. Black-Right-Pointing-Pointer UV-ELA technique causes a rapid heating that provokes the H{sub 2} desorption from the Si surface and bulk material. Black-Right-Pointing-Pointer Next, diffusion of P doped nc-Si films and eventually, for high energy densities would be possible to reach the melting point. Black-Right-Pointing-Pointer These multilayer structures consisting of thin alternating a-Si:H(10 nm) and n-doped nc-Si:H(60 nm) films deposited on SiO{sub 2}. Black-Right-Pointing-Pointer To optimize parameters involved in this processing, FEM numerical analysis of multilayer structures have been performed. Black-Right-Pointing-Pointer The numerical results are compared with exhaustive characterization of the experimental results. - Abstract: UV excimer laser annealing (UV-ELA) is an alternative annealing process that, during the last few years, has gained enormous importance for the CMOS nano-electronic technologies, with the ability to provide films and alloys with electrical and optical properties to fit the desired device performance. The UV-ELA of amorphous (a-) and/or doped nano-crystalline (nc-) silicon films is based on the rapid (nanoseconds) formation of temperature profiles caused by laser radiation that is absorbed in the material and lead to crystallisation, diffusion in solid or even in liquid phase. To achieve the desired temperature profiles and to optimize the parameters involved in the processing of hydrogenated nanocrystalline silicon (nc-Si:H) films with the UV-ELA, a numerical analysis by finite element method (FEM) of a multilayer structure has been performed. The multilayer structures, consisting of thin alternating a-Si:H(10 nm) and n-doped nc-Si:H(60 nm) layers, deposited on a glass substrate, has also been experimentally analyzed. Temperature profiles caused by 193 nm radiation with 25

  3. Surface analysis of the selective excimer laser patterning of a thin PEDOT:PSS film on flexible polymer films

    Energy Technology Data Exchange (ETDEWEB)

    Schaubroeck, David, E-mail: David.Schaubroeck@elis.ugent.be [Center for Microsystems Technology (CMST), imec and Ghent University, Technologiepark 15, B-9052 Ghent (Belgium); De Smet, Jelle; Willems, Wouter [Center for Microsystems Technology (CMST), imec and Ghent University, Technologiepark 15, B-9052 Ghent (Belgium); Cools, Pieter; De Geyter, Nathalie; Morent, Rino [Research Unit Plasma Technology (RUPT), Department of Applied Physics, Faculty of Engineering, Ghent University, Sint-Pietersnieuwstraat 41, B-9000 Ghent (Belgium); De Smet, Herbert; Van Steenbeerge, Geert [Center for Microsystems Technology (CMST), imec and Ghent University, Technologiepark 15, B-9052 Ghent (Belgium)

    2016-07-15

    Highlights: • Laser patterning of thin film PEDOT:PSS on polymer foils is characterized in great detail. • PEDOT:PSS does not need to be fully removed to create electrically insulating patterns. • The underlying polymer foil influences the ablation behavior. - Abstract: Fast patterning of highly conductive polymers like PEDOT:PSS (poly (3,4-ethylene dioxythiophene): polystyrene sulfonate) with lasers can contribute to the development of industrial production of liquid crystal displays on polymer foils. In this article, the selective UV laser patterning of a PEDOT:PSS film on flexible polymer films is investigated. Based on their optical properties, three polymer films are investigated: polyethylene terephthalate (PET), polymethyl methacrylate (PMMA) and cellulose triacetate (TAC). Ablation parameters for a 110 nm PEDOT:PSS film on these polymer films are optimized. A detailed study of the crater depth, topography and surface composition are provided using optical profilometry, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS), respectively. The electrical insulation of the lines is measured and correlated to the crater analyses for different laser settings. Finally, potential ablation parameters for each of the polymer films are derived.

  4. Monovisión con láser de excímeros en pacientes présbitas Monovision with Excimer laser surgery in presbyopic patients

    Directory of Open Access Journals (Sweden)

    Patricia Andújar Coba

    2010-01-01

    previstos que caracterizan a la cirugía con láser de excímeros.OBJECTIVES: To describe the refractive results achieved with Excimer laser surgery in presbyopic patients, both hyperopic and myopic, with monovision. METHODS: A prospective, longitudinal and descriptive study was performed on 60 presbyopic patients, 18 myopic and 42 hyperopic, who underwent Excimer laser surgery to correct presbyopia based on the monovision method at the Corneal and Refractive Surgery Service of «Ramón Pando Ferrer» Cuban Institute of Ophthalmology from February 2009 to February 2010. The variables used were pre- and post-operative visual acuity with correction, visual acuity without binocular correction, both near and distant, and spheral equivalents. For presenting this information, the mean and standard deviation were used for all variables. RESULTS: In the preoperative phase, it was observed that average visual acuity improved from 0,1 and 0,3 for myopic and hyperopic patients without correction, to 0,94 and 0,97 binocular visual acuity without correction for the same groups in the postoperative phase, thus correcting their average spherical equivalent of 4,63 D and +2,21 D respectively. Average near visual acuity for both groups was Jeager (J 1 - 2 and average spheral equivalents reached for distant vision were 0,02 ± 0, 27 D for myopic and +0.09 ± 0,34 D for hyperopic patients. For near vision, i.e. in the non- dominant eye, the spheral equivalent values were 1.7 ± 0,22 D for myopic and 1.4 ± 0,38 D for hyperopic patients. CONCLUSIONS: After surgery both myopic and hyperopic patients experienced improvement in their visual acuity without correction for distant as well as for near vision. Spheral equivalents were widely modified in both groups for the dominant and non-dominant eyes, in order to facilitate the final visual result in both distances with the foreseen precision in the visual results that characterizes the Excimer laser surgery.

  5. Preparation of periodic surface structures on doped poly(methyl metacrylate) films by irradiation with KrF excimer laser

    Science.gov (United States)

    Kalachyova, Yevgeniya; Lyutakov, Oleksiy; Slepicka, Petr; Elashnikov, Roman; Svorcik, Vaclav

    2014-10-01

    In this work, we describe laser modification of poly(methyl methacrylate) films doped with Fast Red ITR, followed by dopant exclusion from the bulk polymer. By this procedure, the polymer can be modified under extremely mild conditions. Creation of surface ordered structure was observed already after application of 15 pulses and 12 mJ cm-2 fluence. Formation of grating begins in the hottest places and tends to form concentric semi-circles around them. The mechanism of surface ordered structure formation is attributed to polymer ablation, which is more pronounced in the place of higher light intensity. The smoothness of the underlying substrate plays a key role in the quality of surface ordered structure. Most regular grating structures were obtained on polymer films deposited on atomically `flat' Si substrates. After laser patterning, the dopant was removed from the polymer by soaking the film in methanol.

  6. Low temperature sputter-deposited ZnO films with enhanced Hall mobility using excimer laser post-processing

    Science.gov (United States)

    Tsakonas, C.; Kuznetsov, V. L.; Cranton, W. M.; Kalfagiannis, N.; Abusabee, K. M.; Koutsogeorgis, D. C.; Abeywickrama, N.; Edwards, P. P.

    2017-12-01

    We report the low temperature (T  ZnO thin films (~140 nm) with Hall mobility of up to 17.3 cm2 V‑1 s‑1 making them suitable for thin film transistor (TFT) applications. The films were deposited by rf magnetron sputtering at T  V‑1 s‑1 at a carrier density of 2.3  ×  1018 cm‑3 was measured from a 1 GΩ as deposited and aged film after the laser treatment. We suggest that the aging of non-processed films reduces structural defects mainly at grain boundaries by air species chemisorption, with concomitant increase in thermal conductivity so that laser processing can have an enhancing effect. Such a processing combination can act synergistically and produce suitable active layers for TFT applications with low temperature processing requirements.

  7. Evaluating the interaction of 308-nm xenon chloride excimer laser with human dentin and enamel hard tissues

    Directory of Open Access Journals (Sweden)

    Mahshid Yaghmaeian-Mahabadi

    2017-11-01

    Full Text Available Background: The pulsed output of the 308 nm XeCl laser and its photoablation action rather than photothermal action offers the ability to remove dental hard tissues with minimal generation of heat in the tissue. Materials and Methods: A total of 20 human molar teeth (ten teeth used as enamel samples and ten teeth used as dentin samples after removing the enamel tissue from their crowns were irradiated by the laser. The crown of each sample was regarded as a cube which its lateral sides were exposed in 2Hz frequency without water cooling. Also, 18 holes for all enamel samples and 18 holes for all dentin samples were obtained. Three different amounts of energy were selected as a variable factor with 6 different numbers of pulses in each energy. The images of these holes were prepared by optic and computer combining, and the amounts of the ablation depth and effective ablation area were calculated using the MATLAB software. Results: The amounts of ablation depth were increased with increasing the number of pulses for both enamel and dentin tissues. The amounts of ablation depth were also increased with increasing the amounts of energy for both enamel and dentin tissues. The greater amounts of ablation depth and effective ablation area were observed in the dentin tissue rather than the enamel tissue. The borders of created holes were reported sharp and clear. Conclusion: The application of the XeCl laser for hard tissue removal and cavity preparation can be possible after some certain modifications.

  8. Suppressed intermixing in InAlGaAs/AlGaAs/GaAs and AlGaAs/GaAs quantum well heterostructures irradiated with a KrF excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Genest, J.; Dubowski, J.J.; Aimez, V. [Universite de Sherbrooke, Centre de recherche en Nanofabrication et Nanocaracteriasation (CRN2), Departement de Genie Electrique et Genie Informatique, Sherbrooke, Quebec (Canada)

    2007-11-15

    The influence of gallium arsenide surface modification induced by irradiation with a KrF excimer laser on the magnitude of the quantum well (QW) intermixing effect has been investigated in InAlGaAs/AlGaAs/GaAs QW heterostructures. The irradiation in an air environment with laser pulses of fluences between 60 and 100 mJ/cm{sup 2} has resulted in the formation of a gallium oxide-rich film at the surface. Following the annealing at 900 C, up to 35 nm suppression of the band gap blue shift was observed in all the laser irradiated samples when compared to the non-irradiated samples. The origin of suppression has been discussed in terms of stress controlled diffusion. (orig.)

  9. Controlling the parameters of YBa2Cu3O(7-delta) high-temperature superconductors through excimer laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dovgii, IA.O.; Kityk, I.V.; Lutsiv, R.V.; Malinich, S.Z.; Nosan, A.V.

    1991-02-01

    Single crystals (2x3 sq mm) of YBa2Cu3O(7{minus}{delta}) high-temperature superconductors were irradiated by an XeCl laser pumped by a gas discharge with a voltage of 35 kW and a frequency of 5 Hz. The formation of the superconducting phase was observed at oxygen pressures of 4-8 kbar. With an increase in oxygen pressure to 20 kbar, the transition temperature increased to 90 K. A possible mechanism of the observed phenomenon is examined.

  10. Controlling the parameters of YBa2Cu3O(7-delta) high-temperature superconductors through excimer laser irradiation

    Science.gov (United States)

    Dovgii, Ia. O.; Kityk, I. V.; Lutsiv, R. V.; Malinich, S. Z.; Nosan, A. V.

    1991-02-01

    Single crystals (2x3 sq mm) of YBa2Cu3O(7-delta) high-temperature superconductors were irradiated by an XeCl laser pumped by a gas discharge with a voltage of 35 kW and a frequency of 5 Hz. The formation of the superconducting phase was observed at oxygen pressures of 4-8 kbar. With an increase in oxygen pressure to 20 kbar, the transition temperature increased to 90 K. A possible mechanism of the observed phenomenon is examined.

  11. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2015-01-01

    Purpose: To evaluate and compare long-term outcomes ofafter photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. Methods: Retrospective single-masked follow-up study of patients treated for myopia between 2007 and 2009 with c...... ±1.0 D of intended refraction. Finally, 100% of cPRK patients and 92% of LASEK patients (P=0.87) were satisfied or very satisfied with the surgery at final follow-up. Conclusion: cPRK and LASEK seemed safe and with high patient satisfaction 4 to 7 years after surgery for high myopia. However, c...

  12. The correlation between the laser energy density and the properties of diamond-like carbon films with Nd:YAG (355 nm) excimer laser

    CERN Document Server

    Jung, H S; Pang, S S; Lee, S Y

    1998-01-01

    Diamond-like carbon (DLC) films were deposited using pulsed laser ablation of graphite target. The deposition process was performed with the change of laser energy density from 8 to 17 J/cm sup 2. collected from analytical results, laser energy density is seen to play an important role in the formation of sp sup 3 carbon bondings in films. Also, the optimal deposition condition for DLC films was proposed and correlated with the laser energy density.

  13. Development and numerical solution of a mechanistic model for corneal tissue ablation with the 193 nm argon fluoride excimer laser

    Science.gov (United States)

    Fisher, Brian T.; Hahn, David W.

    2007-02-01

    We detail the development and implementation of a global ablation model that incorporates a dynamically changing tissue absorption coefficient. Detailed spectroscopic measurements rule out plasma-shielding effects during the laser-tissue interaction and thereby support a photochemical mechanism. The model predicts ablation rate behavior that agrees well with a variety of experimental ablation rate data and that substantially deviates from a static Beer-Lambert model. The dynamic model predicts an enhancement in the tissue absorption coefficient of about 25%-50% as compared with the initial, static value. In addition, the model predicts an increase in the tissue ablation rate as corneal hydration increases, which may provide additional insight into variations in refractive surgery outcome.

  14. LASER PHYSICS: Formation of XeCl excimer molecules as a result of mixing of gas streams excited by a continuous discharge

    Science.gov (United States)

    Mikhkel'soo, V. T.; Treshchalov, A. B.; Peét, V. É.; Yalviste, É. Kh; Belokon', A. A.; Braĭnin, B. I.; Khritov, K. M.

    1987-07-01

    A longitudinal continuous discharge in two independent supersonic gas streams, which were subsequently mixed, was used for nonequilibrium electronic excitation of components undergoing reactions and emitting chemiluminescence. Formation of XeCl excimer molecules as a result of mixing of excited He:Xe = 95:5 and He:HCl(Cl2) = 99:1 streams was deduced from the XeCl* fluorescence spectra (B→X and C→A bands). The steady-state concentration of the XeCl molecules in B and C states determined in the mixing region was ~1010 cm-3 when the pump power was 50 W, so that the efficiency of conversion of the input electrical energy into the excimer fluorescence was ~1%.

  15. Seven year follow-up after advanced surface ablation with excimer laser for treatment of myopia: Long-term outcomes of cooling PRK and LASEK

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    , Odense University Hospital. Inclusion criteria: Age 20-50 years at time of surgery, pre-operative CDVA ≤ 0.10 (logMAR) and no other ocular conditions than myopia with or without astigmatism of maximum 3 D. Exclusion criteria: Pregnancy and eyes having undergone re-treatment. A MEL80 flying-spot excimer......, corneal densitometry and patient satisfaction, although the long-term predictability of cPRK seemed better. Financial Disclosures: None...

  16. ArF excimer laser modulation of TNF-alpha and gelatinase B in NIH 3T3 cells; Modulation de l`expression du TNF-alpha et de la gelatinase B, apres irradiation de fibroblastes NIH 3T3 par un laser a excimeres a 193 NM

    Energy Technology Data Exchange (ETDEWEB)

    Naudy-Vives, C.; Courant, D.; Perot, J.C.; Garcia, J.; Fretier, P.; Court, L.; Dormont, D.

    1995-12-31

    The effects on TNF-alpha and gelatinase B activity in mammalian cells induced by 193 nm argon fluoride excimer laser have been investigated. The data show that a secretion of 92 kDa type IV collagenase and TNF-alpha were increased in cell culture supernatants. Moreover, the 193 nm laser radiation produces a decrease of cell proliferation and an increase of cell activation 8 hours after irradiation. The total protein amount increases with the delivered dose. Same, but less effects were obtained after exposure to a conventional UV lamp at 254 nm. (author). 8 refs.

  17. Controlled reshaping of the front surface of the cornea through its full-area ablation outside of the optical zone with a Gaussian ArF excimer laser beam

    Science.gov (United States)

    Semchishen, A. V.; Semchishen, V. A.

    2014-01-01

    We studied in vitro the response of the topography of the cornea to its full-area laser ablation (the laser beam spot diameter is commensurable with the size of the interface) outside of the central zone with an excimer laser having a Gaussian fluence distribution across the beam. Subject to investigation were the topographically controlled surface changes of the anterior cornea in 60 porcine eyes with a 5 ± 1.25-diopter artificially induced astigmatism, the changes being caused by laser ablation of the stromal collagen in two 3.5-mm-dia. circular areas along the weaker astigmatism axis. Experimental relationships are presented between the actual astigmatism correction and the expected correction for the intact optical zones 1, 2, 3, and 4 mm in diameter. The data for each zone were approximated by the least-squares method with the function d = a + bx. The coefficient b is given with the root-mean-square error. The statistical processing of the data yielded the following results: d = (0.14 ± 0.037)x for the 1-mm-dia. optical zone, (1.10 ± 0.036)x for the 2-mm-dia. optical zone, (1.04 ± 0.020)x for the 3-mm-dia. optical zone, and (0.55 ± 0.04)x for the 4-mm-dia. optical zone. Full astigmatism correction was achieved with ablation effected outside of the 3-mm-dia. optical zone. The surface changes of the cornea are shown to be due not only to the removal of the corneal tissue, but also to the biomechanical topographic response of the cornea to its strain caused by the formation of a dense pseudomembrane in the ablation area.

  18. Spectrum characteristic study of sodium-ethane excimer pairs

    Science.gov (United States)

    Hu, Shu; Gai, Baodong; Wang, Pengyuan; Li, Hui; Tan, Yannan; Liu, Jinbo; Guo, Jingwei

    2017-01-01

    Excimer pumped sodium laser (XPNaL) can accurately achieve lasing at 589.16 nm without any complicated control system to reduce the wavelength error, so XPNaL will provide a novel technical system for sodium beacon laser. In this paper, we studied the Na-C2H6 system, which was an efficient excimer pair. We excited the Na-C2H6 system using a pulsed dye laser with wavelength of 553 nm, and measured lifetime of sodium D2 line based on the fluorescence spectra. Meanwhile, we have also detected strong amplified spontaneous emission (ASE) signal in Na-C2H6 system, through the experimental study, the Na-C2H6 system is considered to own the potential to be utilized in high power XPNaL.

  19. Excimer Ladar Pointer Trackers

    Science.gov (United States)

    Grossman, Jon; Brindley, William E.

    Spaceborne optical pointing and tracking systems have historically used passive sensors. With the advent of space based laser programs ,such as submarine laser communication ( SLC SAT ) and laser atmospheric wind sounder ( LAWS ), it is now possible to conceive of laser based active pointing and tracking systems. In this paper we present some the advantages of going to an active pointer-tracker, the advantages of going to a short wavelength system, and what the performance of this system would be based on current technology.

  20. Development mechanism of high pressure argon plasma produced by irradiation of excimer laser. Ekishima reza ni yori seiseishita koatsuryoku arugon purazuma no seicho kiko

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, J.; Tsuda, N.; Uchida, Y.; Furuhashi, H. (Aichi Inst. of Technology, Aichi (Japan)); Sahashi, T. (Daido Inst. of Technology, Aichi (Japan))

    1994-04-20

    The studies of a high temperature and high density laser plasma are being carried out centering around solid targets, but a high density plasma can be generated also by focused irradiation of a laser light onto a high pressure gas target. However, in this case, studies on a high pressure laser plasma using the ultra-violet beam are seldom conducted. In this paper, the generation mechanism of a plasma generated mainly behind the focal point of the lens is mentioned in case when the ultra violet laser beam is focused and irradiated onto a high pressure argon gas, and it has been compared for study with the plasma generated by a ruby laser. Part of the obtained results is as follows; it has been elucidated that the plasma generated behind the focal point by focusing and irradiating an ultra violet laser beam onto a high pressure argon gas is growing simultaneously by the radiation supported shock wave and the breakdown wave, same as the case of a visible laser beam. When the ultra violet beam with frequency higher than the plasma frequency is irradiated, a plasma grows in front of the focal point too. 6 refs., 9 figs.

  1. Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline

    NARCIS (Netherlands)

    Gijsbers, G. H.; van den Broecke, D. G.; Sprangers, R. L.; van Gemert, M. J.

    1992-01-01

    The effect of force applied to a 430 micron single fiber, delivering 60 pulses of 308 nm XeCl laser radiation at 20 Hz, on the ablation depth in porcine aortic tissue under saline has been investigated. Energy densities of 8, 15, 25, 28, 31, 37, and 45 mJ/mm2 were used. Force was applied by adding

  2. Effects of excimer laser irradiation on the expression of Th17, Treg, TGF-beta1, and IL-6 in patients with psoriasis vulgaris

    Science.gov (United States)

    Xiong, Guo-Xin; Li, Xin-Zhong

    2017-11-01

    The effects of laser irradiation on the expression of T helper 17 (Th17) and regulatory T (Treg) cells and their related cytokines, transforming growth factor beta 1 (TGF-β1) and interleukin-6 (IL-6), respectively, in the peripheral blood of patients with psoriasis vulgaris were investigated. 38 patients with psoriasis vulgaris in the stable state were selected as the treatment group that was treated twice a week for eight weeks. Another 38 healthy persons were chosen as the control group. Before and after treatment, the percentages of Th17 cells and Treg cells in the patients’ peripheral blood were detected using flow cytometry, the content of TGF-β1 and IL-6 in the patients’ sera were detected using enzyme-linked immunosorbent assay, and the extent and severity of lesions were determined by weighing the psoriasis area and severity index (PASI). After laser treatment, the percentage of Th17 cells, the Th17/Treg cell ratio and the level of IL-6 in the peripheral blood of patients with psoriasis in the treatment group were significantly lower than those of the same patients before the treatment (P  psoriasis vulgaris was 84.21%, and the PASI score was significantly lower (P  psoriasis vulgaris.

  3. Discharge-current characteristics in UV-preionized Kr/He, F2/He gas-mixtures and KrF excimer laser gas. Shigaisen yobi denri Kr/He, F2/He kongo kitai hoden oyobi KrF laser reiki hoden no denryu tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, N.; Kawakami, H.; Yukimura, K. (Doshisha University, Kyoto (Japan))

    1992-08-15

    In order to study effects of Kr and F2 on discharge characteristics of KrF excimer laser gas, gap phenomena in Kr/He and F2/He gas-mixtures were observed and discharge current (I[sub d]) was measured. In the range where Kr concentration was over 10% in Kr/He gas, in which production of filamentation as well as glow discharge started, discontinuous change in I[sub d] in the second or third half cycle was observed. According to the results of experiments and model analyses, it was considered that the discontinuity of the current showed the transition point to filamentation. When F2 concentration was in the range between 0.1 and 0.3% in F2/He mixture gas, filamentation and arc with glow were observed. Sine-waveform I[sub d] ended in the first half cycle, and began to flow again after cessation or had almost constant current due to arc and others. When F2 was over 0.4%, only are discharge was observed. It was thus found that F2 has a large effect on discharge characteristics of KrF laser gas. 18 refs., 9 figs.

  4. Pressure and gap length dependence of gap breakdown voltage and discharge current of discharge-pumped KrF excimer laser. Hoden reiki KrF laser no zetsuen hakai den prime atsu to reiki denryu no atsuryoku, gap cho izon sei

    Energy Technology Data Exchange (ETDEWEB)

    Yukimura, K.; Kawakami, H. (Doshisha Univ., Tokyo (Japan)); Hitomi, K. (Kyoto Polytechnic College, Kyoto (Japan))

    1991-04-20

    On the gap destruction characteristics of UV-preionized discharge-pumped KrF excimer laser (charge transfer type) and the electric characteristics of the excited discharge, studies were made by changing the pressure (1.5-3 atm) and the discharge gap length (14-21 mm) of the discharge medium. (1) Gap breakdown voltage and the maximum current of the excited discharge give a similarity by a product of pressure and the gap length at the charge volatge. (2) Insulation breakdown of the gap occurs at the wave front of the applied voltage and the breakdown time gets delayed by the decreasing voltage applied. By setting the ionization index at constant value 20, the gap breakdown voltage is estimated at the error within 10%. (3) The relation between the maximum current, pressure and the gap length product changes the characteristics by the charge voltage of the primary condenser. With the result combined with the standardization of voltage/current of the excited discharge, the electric characteristics at the specific pressure and gap length can be readily known. 10 refs., 10 figs.

  5. High power lasers in manufacturing

    OpenAIRE

    Chatwin, Chris R

    2017-01-01

    Lecture covers a brief history of lasers and the important beam parameters for manufacturing applications. It introduces the main laser types that are appropriate for manufacturing: carbon dioxide lasers, Nd YAG, Diode and fibre lasers, excimer lasers. It then looks at applications to different products and also micro-engineering

  6. Selective irradiation of radicals for biomedical treatment using vacuum ultraviolet light from an excimer lamp

    Science.gov (United States)

    Ono, Ryo; Tokumitsu, Yusuke; Zen, Shungo; Yonemori, Seiya

    2014-10-01

    In plasma medicine, radicals are considered to play important roles. However, the medical effect of each radical, such as OH and O, is unknown. To examine the effect of each radical, selective production of radicals is needed. We developed selective production of radicals for biomedical treatment using a vacuum ultraviolet (VUV) light emitted from an excimer lamp. Selective irradiation of OH radicals can be achieved by irradiating the 172-nm VUV light from a Xe2 excimer lamp to a humid helium flow in a quartz tube. The water molecules are strongly photodissociated by the VUV light to produce OH radicals. A photochemical simulation for the selective OH production is developed to calculate the OH density. The calculated OH density is compared with OH density measured using laser-induced fluorescence (LIF). Selective production of other radicals than OH is also discussed.

  7. EVALUATION OF SKIN-CANCER RISK RESULTING FROM LONG-TERM OCCUPATIONAL EXPOSURE TO RADIATION FROM ULTRAVIOLET-LASERS IN THE RANGE FROM 190 TO 400 NM

    NARCIS (Netherlands)

    Sterenborg, H. J.; de Gruijl, F. R.; Kelfkens, G.; van der Leun, J. C.

    1991-01-01

    The relative risk of occupational exposure to radiation from UV lasers was estimated using a mathematical model based on both epidemiological data and animal experiments. Calculations were performed for the 193 nm ArF excimer laser cornea shaping, the 308 nm XeCl excimer laser for coronary

  8. Testing relativity again, laser, laser, laser, laser

    NARCIS (Netherlands)

    Einstein, A.

    2015-01-01

    laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser,

  9. Refraction Measurements Of Excimer Area Ablated Animal Corneas Using A Modified Autorefractor

    Science.gov (United States)

    Clapham, Terrance N.; Herekar, Satish; Koons, Stephen

    1988-06-01

    Developing refractive surgery techniques usually requires pre-clinical trials with animals before human clinicals are performed. In order to assess the results of the surgery, an accurate and repeatable measurement of the resultant refraction must be made. Normal techniques such as retinoscopy, subjective examinations, and conventional autorefractions all run into problems when animals are involved. The authors have modified a conventional autorefractor and have made measurements on rabbits and monkeys both before and after refractive surgery treatments with an excimer laser. The results showed refractive changes with degrees of myopic correction.

  10. Laser in ophthalmology. Laser i oftalmologien

    Energy Technology Data Exchange (ETDEWEB)

    Syrdalen, P. (Rikshospitalet, Oslo (Norway))

    1991-09-01

    The article presents a brief history of the use of laser in ophthalmology in Norway, from the introduction of the first argon-photocoalulator in 1972 to the excimer laser in 1990. The argon-photocoagulator is in daily us in all Eye Departments in Norway and the main group of patients treated are those with diabetic retionopathy. Glaucoma has been treated with argon-laser with good results for the last ten years. YAG-laser, introduced in Norway in 1985, is used to treat secondary cataracts which occur after extracapsular cataract extractions and implantation of artificial lenses. In 1990, the excimer laser was introduced for refractive surgery (myopia, astigmatism). 4 refs., 6 figs., 1 tab.

  11. Deposition and characterization of ITO films produced by laser ablation at 355 nm

    DEFF Research Database (Denmark)

    Holmelund, E.; Thestrup Nielsen, Birgitte; Schou, Jørgen

    2002-01-01

    and at high substrate temperatures, the specific resistivity of the films, 2–3×10-4 Ω cm, is comparable to values obtained with excimer lasers, whereas the resistivities obtained at room temperature are somewhat higher than those of films produced by excimer lasers. The transmission coefficient of visible...... light, about 0.9, is also comparable to values for films deposited by excimer lasers. The crystalline structure of films produced at 355 nm is similar to that of samples produced by these lasers.......Indium tin oxide (ITO) films have been deposited by pulsed laser deposition (PLD) at 355 nm. Even though the absorption of laser light at the wavelength 355 nm is much smaller than that of the standard excimer lasers for PLD at 248 nm and 193 nm, high-quality films can be produced. At high fluence...

  12. The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 2: the consequences of treating astigmatism on an incorrect axis via excimer laser

    Directory of Open Access Journals (Sweden)

    Motwani M

    2017-05-01

    Full Text Available Manoj Motwani Motwani LASIK Institute, San Diego, CA, USA Purpose: To show how an incorrect manifest astigmatism axis can cause an abnormal induced astigmatism on a new axis. Patients and methods: Four eyes of three patients were treated primarily with WaveLight® EX500 wavefront optimized (WFO treatments for astigmatism. All four eyes needed enhancements and were analyzed retrospectively via WaveLight® Contoura to determine the reason for the incorrect astigmatism treatment. Two of the eyes were retreated with topographic-guided ablation, and two were treated with WFO correction. Results: The eyes that had an incorrect manifest axis resulted in a new abnormal induced astigmatism on a wholly new axis. Treatment with topographic-guided ablation completely eliminated the newly induced astigmatism. Treatment with WFO of an abnormal induced astigmatism corrected the refraction but still left topographic evidence of the abnormal astigmatism behind. One eye was incorrectly treated for astigmatism due to coma affecting refraction when the patient was dilated. This eye had a normal induced astigmatism on a perpendicular axis and was corrected using WFO. The use of manifest refraction with WaveLight® Contoura topographic-guided ablation will lead to incorrect astigmatism correction when the manifest astigmatism and axis differ from the WaveLight® Contoura measured. Conclusion: Correction of an incorrect manifest refraction astigmatic axis does not simply create undercorrection of the astigmatism but induces an entirely new abnormal astigmatism on a different axis. Manifest refraction is less accurate and can lead to abnormal astigmatism when laser ablation is performed. Keywords: WaveLight Contoura, astigmatism treatment, asymmetric astigmatism, topographic guide ablation, higher order aberrations, Contoura with LYRA Protocol, LASIK, PRK

  13. Near-infrared laser-induced fluorescence detection in column liquid chromatography. A comparison of various lasers and detection systems. II*. Pulsed lasers.

    NARCIS (Netherlands)

    Mank, A.J.G.; Velthorst, N.H.; Brinkman, U.A.T.; Gooijer, C.

    1995-01-01

    The applicability of two pulsed lasers, a XeCl-excimer/dye laser and a Nd:YAG/dye laser combination, as excitation sources for near-infrared (NIR) laser-induced fluorescence (LIF) detection in column liquid chromatography (LC) is studied. Using gradient LC, the best detection limit for the model

  14. Laser-induced breakdown spectra of Zn2 molecule in the violet region

    Indian Academy of Sciences (India)

    The study of excimer and van der Waals molecules such as Hg2, Cd2 and Zn2 are of current interest as they are potential candidates for the possible development of new high power excimer lasers. Group IIB metal dimers (Hg2, Cd2 and Zn2) have essentially repulsive ground states with very shallow van der Walls minima.

  15. Reversible Femtosecond Laser-Assisted Myopia Correction: A Non-Human Primate Study of Lenticule Re-Implantation after Refractive Lenticule Extraction: e67058

    National Research Council Canada - National Science Library

    Andri K Riau; Romesh I Angunawela; Shyam S Chaurasia; Wing S Lee; Donald T Tan; Jodhbir S Mehta

    2013-01-01

      LASIK (laser-assisted in situ keratomileusis) is a common laser refractive procedure for myopia and astigmatism, involving permanent removal of anterior corneal stromal tissue by excimer ablation beneath a hinged flap...

  16. Reversible femtosecond laser-assisted myopia correction: a non-human primate study of lenticule re-implantation after refractive lenticule extraction

    National Research Council Canada - National Science Library

    Riau, Andri K; Angunawela, Romesh I; Chaurasia, Shyam S; Lee, Wing S; Tan, Donald T; Mehta, Jodhbir S

    2013-01-01

    LASIK (laser-assisted in situ keratomileusis) is a common laser refractive procedure for myopia and astigmatism, involving permanent removal of anterior corneal stromal tissue by excimer ablation beneath a hinged flap...

  17. Excimer laser surface ablation: a review of recent literature

    National Research Council Canada - National Science Library

    O'Brart, David PS

    2014-01-01

    ...‐epithelial keratomileusis ( LASEK ), microkeratome‐assisted PRK (epi‐ LASIK ) and trans‐epithelial (laser‐assisted) PRK , to help elucidate where and how surface ablation may best fit into current refractive surgical practice...

  18. Optical engineering of an excimer laser ophthalmic surgery system

    Science.gov (United States)

    Yoder, Paul R., Jr.

    1991-04-01

    We outline the interrelationships between the various major subsystems of an apparatus being developed in the USA for in vivo surgical recontouring of the human cornea to correct refractive errors and/or to remove damaged tissue. We then discuss five significant optical engineering problems that had to be solved during the design of this apparatus in order for the overall system to function properly.

  19. Laser materials processing with diode lasers

    OpenAIRE

    Li, Lin; Lawrence, Jonathan; Spencer, Julian T.

    1996-01-01

    Laser materials processing is currently dominated by CO2, Nd-YAG and Excimer lasers. Continuous advances in semiconductor laser technology over the last decade have increased the average power output of the devices annualy by two fold, resulting in the commercial availability of the diode lasers today with delivery output powers in excess of 60W in CW mode and 5kW in qasi-CW mode. The advantages of compactness, high reliability, high efficiency and potential low cost, due to the mass producti...

  20. Mechanisms of tissue damage during ArF excimer endolaser microsurgery

    Science.gov (United States)

    Palanker, Daniel V.; Turovets, Igor; Lewis, Aaron

    1996-05-01

    The novel fiberoptic delivery system for the 193 nm excimer laser has been developed for vitreoretinal microsurgery. During the application of this laser in a liquid environment both the short-living cavitation bubbles and hydrogen gas-containing insoluble bubbles are produced. In present work we study the influence of these bubbles generated in free liquid on membranous tissue. Damage zones resulting from application of pulse trains at various repetition rates were investigated using vital stains which indicate the increase of cell membrane permeability. Cavitation bubbles were created by laser above the tissue in a highly absorbing liquid--Hartmann's solution with an addition of 7% albumin. These conditions simulate a situation in which a thin membrane separated from the underlying retina by layer of liquid is cut. After application of 50 pulses at 20 Hz at energy levels varying from 14 to 68 (mu) J per pulse we have detected cell damage at corresponding distances varying from 100 to 1200 microns. In Hartmann's solution (physiological medium), where the cavitation bubbles could not be formed at the same applied energies, the laser damage has been detected only at the distances varying from 150 to 200 microns. Penetration depth of the laser radiation in this solution is about 50 microns. The cells damage in this case probably has a photochemical nature. The difference in damage distance obtained at 1 and 20 Hz repetition rates can be explained by the influence of insoluble gas bubbles that grow at the tip exit and play a role of a transparent medium for the laser radiation. This effect probably determines the minimal distance at which the surgeon can apply the laser in standard physiological medium without being concerned with underlying cells damage. On the other hand, this phenomenon enable to destroy the upper level of cells in tissue without the deep penetrating mechanical influence associated with cavitation bubble-based tissue removal.

  1. Pulsed laser ablation of LaSrCoO

    NARCIS (Netherlands)

    Span, E.A.F.; Roesthuis, Frank J.G.; Blank, David H.A.; Rogalla, Horst

    1999-01-01

    The ablation process of La0.5Sr0.5CoO3 by a spatial uniform 248 nm excimer laser beam has been characterized. Ablation rates, changes in the target surface morphology and composition have been studied as a function of the laser fluence. The dependence of the ablation rate on the laser fluence has

  2. Effects of laser wavelength and fluence on the growth of ZnO thin films by pulsed laser deposition

    NARCIS (Netherlands)

    Craciun, V.; Amirhaghi, S.; Craciun, D.; Elders, J.; Gardeniers, Johannes G.E.; Boyd, Ian W.

    Transparent, electrically conductive and c-axis oriented ZnO thin films have been grown by the pulsed laser deposition (PLD) technique on silicon and Corning glass substrates employing either a KrF excimer laser (λ = 248 nm) or a frequency-doubled Nd:YAG laser (λ = 532 nm). The crystalline

  3. Shadowgraphic imaging of material removal during laser drilling with a long pulse eximer laser

    NARCIS (Netherlands)

    Schoonderbeek, A.; Biesheuvel, C.A.; Hofstra, R.M.; Boller, Klaus J.; Meijer, J.

    2005-01-01

    After the development of a novel XeCl excimer laser with a nearly diffraction-limited beam and 175 ns pulse length, research was done on different industrial applications of this laser. Hole drilling, one of these applications, was studied extensively. A better understanding of the drilling process

  4. Internal Dynamics of Dendritic Molecules Probed by Pyrene Excimer Formation

    Directory of Open Access Journals (Sweden)

    Jean Duhamel

    2012-01-01

    Full Text Available This review exposes the current poor understanding of the internal segmental chain dynamics of dendrimers in solution probed by monitoring the process of excimer formation between pyrene labels covalently attached to the chain ends of dendrimers. The review begins by covering the bases of fluorescence and the kinetics of pyrene excimer formation before describing a procedure based on the Model Free (MF analysis that is used to analyze quantitatively the fluorescence decays acquired for dendrimers, the ends of which have been fully and covalently labeled with pyrene. Comparison of the various trends obtained by different research groups describing the efficiency of pyrene excimer formation with the generation number of dendrimers illustrates the lack of consensus between the few studies devoted to the topic. One possible reason for this disagreement might reside in the presence of minute amounts of unattached pyrene labels which act as potent fluorescent impurities and affect the analysis of the fluorescence spectra and decays in an uncontrolled manner. The review points out that the MF analysis of the fluorescence decays acquired with pyrene-labeled dendrimers enables one to account for the presence of unattached pyrene and to retrieve information about the internal segmental dynamics of the dendrimer. It provides guidelines that should enable future studies on pyrene-labeled dendrimers to yield results that are more straightforward to interpret.

  5. A review and meta-analysis of corneal cross-linking for post-laser vision correction ectasia

    Directory of Open Access Journals (Sweden)

    Qi Wan

    2017-09-01

    Conclusion: The study showed that CXL is a promising treatment to stabilize the keratectasia after Excimer Laser Refractive Surgery. Further long-term follow-up studies are necessary to assess the persistence of the effect of the CXL.

  6. Laser in operative dentistry

    Directory of Open Access Journals (Sweden)

    E. Yasini

    1994-06-01

    Full Text Available Today laser has a lot of usage in medicine and dentistry. In the field of dentistry, laser is used in soft tissue surgery, sterilization of canals (in root canal therapy and in restorative dentistry laser is used for cavity preparation, caries removal, sealing the grooves (in preventive dentistry, etching enamel and dentin, composite polymerization and removal of tooth sensitivity. The use of Co2 lasers and Nd: YAG for cavity preparation, due to creating high heat causes darkness and cracks around the region of laser radiation. Also due to high temperature of these lasers, pulp damage is inevitable. So today, by using the Excimer laser especially the argon floride type with a wavelength of 193 nm, the problem of heat stress have been solved, but the use of lasers in dentistry, especially for cavity preparation needs more researches and evaluations.

  7. International Symposium on Gas Flow and Chemical Lasers, 8th, Madrid, Spain, Sept. 10-14, 1990, Proceedings

    Science.gov (United States)

    Orza, Jose M.; Domingo, C.

    1991-03-01

    Papers are presented on current research developments and applications related to high-powered lasers. Recent advances in excimer laser technology, electron-beam-pumped excimer lasers, discharge technology for excimer lasers, and pulsed XeF lasers are examined. Consideration is given to short-wavelength lasers, chemical oxygen iodine lasers, and vibrational chemical lasers. Papers are presented on CO2, CO, N2O lasers, coupled CO2 lasers, laser induced perturbation in pulsed CO2 lasers, construction of sealed-off CO2 lasers, and computer modeling of discharge-excited CO gas flow. Topics discussed include gas-dynamic lasers, discharge and flow effects, matrix and laser optics and laser beam parameters. Laser-matter interactions, laser-induced surface plasma, plasma motion velocity along laser beams and thermocapillary effects are also discussed. Applications of laser technology are examined and high-speed laser welding, welding results, laser ablation, laser steel processing, and numerical modeling of laser-matter interaction in high-intensity laser applications are considered. (For individual items see A93-26381 to A93-26422)

  8. Intramolecular excimer and exciplex emission of 1,4-dipyrenyl substituted cyclohexasilane

    NARCIS (Netherlands)

    van Walree, C.A.; Kaats-Richters, V.E.M.; Jenneskens, L.W.; Williams, R.M.; van Stokkum, I.H.M.

    2002-01-01

    Intramolecular excimer emission is observed for cis-1,4-di(1-pyrenyl)decamethylcyclohexasilane in nonpolar solvents. Time-resolved fluorescence spectroscopy and kinetic modelling indicate that the driving force of excimer formation is very small, and that the process is governed by the flexibility

  9. Applications of lasers and electro-optics

    Science.gov (United States)

    Tan, B. C.; Low, K. S.; Chen, Y. H.; Ahmad, Harith; Tou, T. Y.

    Supported by the IRPA Programme on Laser Technology and Applications, many types of lasers have been designed, constructed and applied in various areas of science, medicine and industries. Amongst these lasers constructed were high power carbon dioxide lasers, rare gas halide excimer lasers, solid state Neodymium-YAG lasers, nitrogen lasers, flashlamp pumped dye lasers and nitrogen and excimer laser pumped dye lasers. These lasers and the associated electro-optics system, some with computer controlled, are designed and developed for the following areas of applications: (1) industrial applications of high power carbon dioxide lasers for making of i.c. components and other materials processing purposes -- prototype operational systems have been developed; (2) Medical applications of lasers for cancer treatment using the technique of photodynamic therapy -- a new and more effective treatment protocol has been proposed; (3) agricultural applications of lasers in palm oil and palm fruit-fluorescence diagnostic studies -- fruit ripeness signature has been developed and palm oil oxidation level were investigated; (4) development of atmospheric pollution monitoring systems using laser lidar techniques -- laboratory scale systems were developed; and (5) other applications of lasers including laser holographic and interferometric methods for the non destructive testing of materials.

  10. Photo-induced growth of dielectrics with excimer lamps

    Science.gov (United States)

    Boyd, Ian W.; Zhang, Jun-Ying

    2001-08-01

    The underlying principles and properties of vacuum ultraviolet (VUV) and ultraviolet (UV) radiation (excimer lamps), generated by a dielectric barrier discharge in a rare-gas (Rg) or a mixture of Rg and halogen, are discussed. Compared with conventional sources, these excimer lamps offer narrow-band radiation at various wavelengths from 108-354 nm and over large areas with high efficiencies and high power densities. The variety of available wavelengths offers an enormous potential for new industrial applications in materials processing. Previously, photo-oxidation of silicon, germanium and silicon-germanium and photo-deposition of single- and multi-layered films of silicon oxide, silicon nitride, and silicon oxynitride have been demonstrated by using excimer lamps. This paper reviews the progress on excimer lamp-assisted growth of high dielectric constant (Ta2O5, TiO2 and PZT) and low dielectric constant (polyimide and porous silica) thin films by photo-CVD and sol-gel processing, summarizes the properties of photo-induced growth of Ta2O5 films and discusses the effect and mechanism of low temperature UV annealing with 172 nm radiation. Metal oxide semiconductor capacitors based on the photo-induced Ta2O5 films grown directly on Si at low temperatures exhibit excellent electrical properties. Leakage current densities as low as 5.2×10-7 A cm-2 and 2.41×10-7 A cm-2 at 1 MV cm-1 have been achieved for the as-grown Ta2O5 films deposited by photo-induced sol-gel processing and photo-CVD, respectively-several orders of magnitude lower than for any other as-grown films prepared by any other technique. A subsequent low temperature (400°C) UV annealing step improves these to 10-8 A cm-2. These values are comparable to those only previously achieved for films annealed at high temperatures between 600°C and 1000°C. These properties make the photo-induced growth of Ta2O5 layers suitable alternative to SiO2 for high density DRAM application.

  11. Excimer Emission using 20keV Electron Beam Excitation

    Science.gov (United States)

    Wieser, J.; Ulrich, A.; Murnick, D. E.

    1996-10-01

    A small, continuously emitting rare gas excimer light source has been developed. The gas is excited by a 20keV dc-electron beam. A 300nm thick, 1×1mm^2 SiNx foil sustaining a pressure difference up to 2bar, separates the target volume from the high vacuum part of the electron gun. Spectra of the rare gases Ar, Kr, and Xe have been studied. The monochromator detector system was intensity calibrated in the wavelength range from 115nm to 320nm. Electron beam currents of typically 1μA were used for excitation. When used as a VUV lamp on the second excimer continua, energy conversion efficiencies of 30% were obtained. Emissions originating from the so called left turning points have been clearly observed at 155, 173, and 222nm in Ar_2^*, Kr_2^*, and Xe_2^*, respectively. The so called third continua between 185nm and 240nm (Ar), 220nm and 250nm (Kr), and at 270nm (Xe) have been studied. A new continuum in Xe at 280nm was found. (Funded by the A.v.Humboldt Foundation and NSF (CTS 94-19440). The authors acknowledge support by H. Huggins, A. Liddle and W.L. Brown (Bell Laboratories, Lucent Technologies))

  12. Smartphone-enabled filterless fluorescence assay utilizing the pyrene excimer

    Science.gov (United States)

    Goertz, John P.; White, Ian M.

    2015-03-01

    Fluorescence microscopy offers a number of advantages for cell- and biomarker-based diagnostics with regards to ease of use and interpretation, sensitivity, and specificity. However, its use in low-resource settings is often hindered by the need for bulky microscopes with expensive excitation and filter setups. While many advances have been made towards utilizing smartphones as microscopes, there remains a reliance on complex attachments to facilitate fluorescence microscopy. Here, we report progress towards a filter-less fluorescent assay utilizing ultraviolet light, an unmodified smartphone, and pyrene-labeled aptamers. The pyrene monomer is excited at a wavelength of 350 nm and emits at approximately 390 nm; when two pyrene molecules are brought into close proximity, however, they form an excimer which emits at approximately 490 nm. We have engineered pyrene-conjugated DNA sequences such that the fluorophores, normally in monomeric configuration, are brought into proximity upon binding of the DNA to its target. The large Stokes shift between excitation and emission of the excimer allows us to detect such biorecognition events with an unfiltered smartphone camera, enabling the use of this assay in low-resource settings where portability and easeof- use are paramount.

  13. 193nm high power lasers for the wide bandgap material processing

    Science.gov (United States)

    Fujimoto, Junichi; Kobayashi, Masakazu; Kakizaki, Koji; Oizumi, Hiroaki; Mimura, Toshio; Matsunaga, Takashi; Mizoguchi, Hakaru

    2017-02-01

    Recently infrared laser has faced resolution limit of finer micromachining requirement on especially semiconductor packaging like Fan-Out Wafer Level Package (FO-WLP) and Through Glass Via hole (TGV) which are hard to process with less defect. In this study, we investigated ablation rate with deep ultra violet excimer laser to explore its possibilities of micromachining on organic and glass interposers. These results were observed with a laser microscopy and Scanning Electron Microscope (SEM). As the ablation rates of both materials were quite affordable value, excimer laser is expected to be put in practical use for mass production.

  14. Investigation of Pyrene Excimer formation in various manufacturing processes and ionic structures

    Science.gov (United States)

    Jang, Hyun-Sook; Nieh, Mu-Ping

    2013-03-01

    Electrospun pyrene (Py)/polystyrene/tetrabutylammonium hexafluorophosphate (TBAPF6) thin films can provide high-sensitivity and high-selectivity detection of nitro-aromatic explosives through fluorescence quenching of the Py excimers. However, we have found that the formation of Py excimers in Py/PS/TBAPF6 thin films depends greatly on the manufacturing processes. Our results indicate that high solvent vapor pressure promotes the Py excimer fluorescence, while high temperature (around or greater than Tg of the PS) has an opposite effect in absence of solvent - reducing the Py excimer fluorescence. Moreover, we have found that salts structure such as cation chain length, anion strength can significantly affect the formation of Py excimer both in solution and solid state, presumably due to self-aggregation of the salts and electrostatic interactions between ions and pyrene excimer. 13C-NMR and steady-state fluorescence result indicate that the salt induces peak shift to the downfield in the spectra and quenches the Py excimer intensity drastically. Ph.D. Candidate, Institute of Material Science, Polymer program

  15. A Review of Luminescent Anionic Nano System: d10 Metallocyanide Excimers and Exciplexes in Alkali Halide Hosts

    Directory of Open Access Journals (Sweden)

    Howard H. Patterson

    2013-06-01

    Full Text Available Dicyanoaurate, dicyanoargentate, and dicyanocuprate ions in solution and doped in different alkali halide hosts exhibit interesting photophysical and photochemical behavior, such as multiple emission bands, exciplex tuning, optical memory, and thermochromism. This is attributed to the formation of different sizes of nanoclusters in solution and in doped hosts. A series of spectroscopic methods (luminescence, UV-reflectance, IR, and Raman as well as theoretical calculations have confirmed the existence of excimers and exciplexes. This leads to the tunability of these nano systems over a wide wavelength interval. The population of these nanoclusters varies with temperature and external laser irradiation, which explains the thermochromism and optical memory. DFT calculations indicate an MLCT transition for each nanocluster and the emission energy decreases with increasing cluster size. This is in agreement with the relatively long life-time for the emission peaks and the multiple emission peaks dependence upon cluster concentration.

  16. Power and pulse energy scaling for high-volume UV-laser microprocessing

    Science.gov (United States)

    Delmdahl, Ralph; Haupt, Oliver; Bragin, Igor; Albrecht, Hans-Stephan

    2017-02-01

    In industrial laser micro processing, throughput is as important as process quality. Treating large areas in minimum time is pivotal in achieving reduced unit costs in high-volume production. Excimer lasers meet the requirements for clean and precise structuring and enable the smallest structures in an efficient way. The latest technical developments in high power excimer lasers is bound to take cost-efficient UV-laser micro processing to the next level and bridges the gap between achievable precision and achievable throughput. New excimer laser developments and beam concepts together with latest performance data for upscaling both UV power and UV pulse energy will be the topic of this paper against the background of upcoming market trends and high volume applications.

  17. Laser Ablation for Medical Applications

    Science.gov (United States)

    Hayashi, Ken-Ichi

    Medical applications of laser are measurement, laser surgery, in-situ monitoring, and processing of medical devices. In this paper, author briefly reviews the trends of medical applications, describes some new applications, and then discuss about the future trends and problems of medical applications. At present, the domestic market of laser equipment for medical applications is nearly 1/10 of that for industrial applications, which has registered significant growth continuously. Laser surgery as a minimum invasive surgery under arthroscope is expected to decrease the pain of patients. Precise processing such as cutting and welding is suitable for manufacturing medical devices. Pulsed laser deposition has been successfully applied to the thin film coating. The corneal refractive surgery by ArF excimer laser has been widely accepted for its highly safe operation. Laser ablation for retinal implant in the visual prosthesis is one of the promising applications of laser ablation in medicine. New applications with femtosecond laser are expected in the near future.

  18. Excimer lamp as an effective alternative treatment for severe alopecia areata

    Directory of Open Access Journals (Sweden)

    Tzu-Chien Hsu

    2015-09-01

    Full Text Available The treatment response of alopecia areata (AA is often unpredictable. The aim of this study was to report the efficacy of an excimer lamp in treating AA. Seventeen AA patients were included. The overall response rate was 41.1%, and the satisfactory response rate was 29.4%. In patients with severe AA, the response rate was 50%. The therapeutic effect of the excimer lamp was evident by internal control. The onset of improvement occurred after 2 months, and only mild side effects were noted. Our results suggest that the 308-nm excimer lamp is a safe alternative treatment for AA, including those with severe AA.

  19. Defects of crystal structure of Hg1-xCdxTe thin layers growing by pulsed laser deposition

    NARCIS (Netherlands)

    Virt, IS; Rudyj, IO; Frugynskiji, MS; Kurilo, [No Value; Sagan, P; Zawislak, J; Kuzma, M

    2003-01-01

    Hg1-xCdxTe layers have been obtained by pulsed laser deposition method using two types of lasers: YAG:Nd3+ (tau = 250 mus or 40 ns) and excimer (tau = 25 ns). The crystal structures of layers were investigated by the electron diffraction method. The dependence of the laser beam parameters on the

  20. Monitoring excimer formation of perylene dye molecules within PMMA-based nanofiber via FLIM method

    Science.gov (United States)

    Inci, Mehmet Naci; Acikgoz, Sabriye; Demir, Mustafa Muamer

    2016-04-01

    Confocal fluorescence lifetime imaging microscopy method is used to obtain individual fluorescence intensity and lifetime values of aromatic Perylene dye molecules encapsulated into PMMA based nanofibers. Fluorescence spectrum of aromatic hydrocarbon dye molecules, like perylene, depends on the concentration of dye molecules and these dye molecules display an excimeric emission band besides monomeric emission bands. Due to the dimension of a nanofiber is comparable to the monomer emission wavelength, the presence of nanofibers does not become effective on the decay rates of a single perylene molecule and its lifetime remains unchanged. When the concentration of perylene increases, molecular motion of the perylene molecule is restricted within nanofibers so that excimer emission arises from the partially overlapped conformation. As compared to free excimer emission of perylene, time-resolved experiments show that the fluorescence lifetime of excimer emission of perylene, which is encapsulated into NFs, gets shortened dramatically. Such a decrease in the lifetime is measured to be almost 50 percent, which indicates that the excimer emission of perylene molecules is more sensitive to change in the surrounding environment due to its longer wavelength. Fluorescence lifetime measurements are typically used to confirm the presence of excimers and to construct an excimer formation map of these dye molecules.

  1. Laser Induced Surface Chemical Epitaxy

    Science.gov (United States)

    1990-03-01

    eV was observed in this study for DMTe adlay ,,;s annealed at 423 K, a condition which is likely to produce a metallic Te adlayer , the Cd 3d5 /2...processes were studied by irradiating the adlayer with ultraviolet photons produced by a Questek excimer laser. These were introduced into the deposition...binding energy observed for similarly annealed DMCd adlayers was 405.1 eV. Based on room temperature measurements and ligand shift and electronegativity

  2. Laser characteristics and interferometric process and sensor applications

    Science.gov (United States)

    Glatz, Otto

    2005-04-01

    Begin Fiber Bragg Gratings (FBGs) are basic elements in DWDM technology. They are produced by UV illumination. UV light sources have been steadily improved to meet the demands of FBG writing industry. We want to characterize some parameters of interest of a simple, line-narrowed excimer laser source, its improvements and contribution to interferometric non-proximity FBG writing. Parameters of interest to be discussed are the temporal and spatial coherence length, the beam stability and spectrum control of produced FBG. With a temporal coherence length of ~ 5 mm it is possible to utilize cost efficient excimer laser technology for the interferometric non-proximity FBG writing process. Correspondingly the line-narrowed Excimer laser can replace expensive frequency doubled Argon ion lasers driving interferometric FBG writing set-ups in production and R & D. Beyond it FBGs for sensor applications play an important role. They have the potential for the measurement of strain / deformation and temperature with applications including monitoring of highways, bridges, aerospace components and chemical and biological sensors. We want to discuss the requirements for excimer lasers for this application: The spatial coherence length, beam profile, pointing and energy stability.

  3. UV laser ablation of parylene films from gold substrates

    Energy Technology Data Exchange (ETDEWEB)

    O. R. Musaev, P. Scott, J. M. Wrobel, and M. B. Kruger

    2009-11-19

    Parylene films, coating gold substrates, were removed by laser ablation using 248 nm light from an excimer laser. Each sample was processed by a different number of pulses in one of three different environments: air at atmospheric pressure, nitrogen at atmospheric pressure, and vacuum. The laser-induced craters were analyzed by optical microscopy and x-ray photoelectron spectroscopy. Multi-pulse ablation thresholds of gold and parylene were estimated.

  4. Very Heavily Doped N-Type GaAs Obtained With Pulsed Laser Annealing

    Science.gov (United States)

    Rys, Andrzej; Chin, Tim; Compaan, Alvin; Bhat, Ajit

    1988-08-01

    A study of carrier activation and mobility was performed in pulsed laser annealed samples of GaAs implanted with doses of Si and Se from 2.2x1012 to 6.0x1014 cm-2. The samples were annealed using a pulsed XeCl excimer laser ( λ=308 nm) and a pulsed dye laser ( λ=728 nm) with energy densities from 0.1 to 0.9 J/cm2 and a 10 nsec pulse. Very high carrier concentrations of 3x1019 and 1.5x1019 cm-3 were obtained for best n-type GaAs samples annealed with the dye laser and excimer laser, respectively. Dye laser consistently produced higher activation than excimer laser annealing. A transient reflectivity experiment was performed to identify the GaAs melt threshold and the melt phase dynamics of the GaAs,under the nitride cap. The threshold energies for cap damage were 0.34 and 0.12 J/cm2 for excimer and dye lasers, respectively. High carrier activation, as measured by Van der Pauw method, was achieved even for lightly doped samples although the room temperature Hall mobility was low. Raman spectroscopy was used to identify the threshold energies for the GaAs implant layer recrystallization and for optimum carrier activation.

  5. Lasers.

    Science.gov (United States)

    Passeron, T

    2012-12-01

    Lasers are a very effective approach for treating many hyperpigmented lesions. They are the gold standard treatment for actinic lentigos and dermal hypermelanocytosis, such as Ota nevus. Becker nevus, hyperpigmented mosaicisms, and lentigines can also be successfully treated with lasers, but they could be less effective and relapses can be observed. However, lasers cannot be proposed for all types of hyperpigmentation. Thus, freckles and café-au-lait macules should not be treated as the relapses are nearly constant. Due to its complex pathophysiology, melasma has a special place in hyperpigmented dermatoses. Q-switched lasers (using standard parameters or low fluency) should not be used because of consistent relapses and the high risk of post-inflammatory hyperpigmentation. Paradoxically, targeting the vascular component of the melasma lesion with lasers could have a beneficial effect. However, these results have yet to be confirmed. In all cases, a precise diagnosis of the type of hyperpigmentation is mandatory before any laser treatment, and the limits and the potential side effects of the treatment must be clearly explained to patients. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  6. [Lasers].

    Science.gov (United States)

    Passeron, T

    2012-11-01

    Lasers are a very effective approach for treating many hyperpigmented lesions. They are the gold standard treatment for actinic lentigos and dermal hypermelanocytosis, such as Ota nevus. Becker nevus, hyperpigmented mosaicisms, and lentigines can also be successfully treated with lasers, but they could be less effective and relapses can be observed. However, lasers cannot be proposed for all types of hyperpigmentation. Thus, freckles and café-au-lait macules should not be treated as the relapses are nearly constant. Due to its complex pathophysiology, melasma has a special place in hyperpigmented dermatoses. Q-switched lasers (using standard parameters or low fluency) should not be used because of consistent relapses and the high risk of post-inflammatory hyperpigmentation. Paradoxically, targeting the vascular component of the melasma lesion with lasers could have a beneficial effect. However, these results have yet to be confirmed. In all cases, a precise diagnosis of the type of hyperpigmentation is mandatory before any laser treatment, and the limits and the potential side effects of the treatment must be clearly explained to patients. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  7. Mid-infrared pulsed laser ablation of the arterial wall. Mechanical origin of "acoustic" wall damage and its effect on wall healing

    NARCIS (Netherlands)

    van Erven, L.; van Leeuwen, T. G.; Post, M. J.; van der Veen, M. J.; Velema, E.; Borst, C.

    1992-01-01

    Pulsed mid-infrared lasers are an alternative to excimer lasers for transluminal angioplasty. The mid-infrared lasers, however, were reported to produce "acoustic" wall damage that might impair the immediate and long-term results. To study the immediate and long-term effects on the arterial wall,

  8. Lasers and beam delivery options for polycrystalline thin-film scribing

    Science.gov (United States)

    Compaan, A. D.; Matulionis, I.; Nakade, S.

    1999-03-01

    We have investigated the use of several different types of lasers for scribing of the thin film materials: CdTe, CuInGaSe2, ZnO, SnO2, Mo, Al, and Au. The lasers included several types of Nd: YAG (1064 and 532 nm wavelengths), Cu vapor (511/578 nm), XeCl excimer (308 nm), and KrF excimer (248 nm). Pulse durations ranged from ˜0.1 nsec to ˜250 ns. We found that the Nd: YAG systems work well for almost all of the above materials except for the transparent conductor ZnO, for which the two excimer lasers showed good performance. Pulse duration was found generally not to be critical except for the case of CIGS on Mo where longer pulse durations appear advantageous.

  9. The Advanced Oxidation Process (UV-Ozonation Type) Assisted By Excimer Lamp

    Science.gov (United States)

    Ikematsu, Tomokazu; Hayashi, Nobuya; Ihara, Satoshi; Satoh, Saburoh; Yamabe, Chobei

    2003-10-01

    The advanced oxidation processes utilizing the excimer lamp was developed for water purification. The UV light with the wavelength of 222nm that destructs the hydrogen peroxide to hydroxyl radical realizes the AOPs. In this paper, the KrCl excimer lamp with the wavelength of 222 nm was adopted for UV-ozonation type AOP, in order to treat the water with organic acid (humic acid). The lamp was made of quartz glasses with a coaxial cylindrical shape. The grounded copper electrode was rolled on the outer side of the glass tube. The excimer gas flows in the gap of the glass tube between outer and inner electrodes. The UV light from the discharge was irradiated to ozonated water that flows inside the glass tube. The enhancement of reduction rate of the organic compound dissolved in water was achieved using UV excimer lamp with the wavelength of 222 nm. When the excimer gas pressure was 200 Torr, maximum discharge power was obtained and light emission intensity at 222 nm was highest. The reduction rate of the UV light irradiation (9 kV, 200 Torr) was larger than that of ozonation only, and the reduction rate was improved from 40

  10. Contrasting the beam interaction characteristics of selected lasers with a partially stabilised zirconia (PSZ) bio-ceramic

    OpenAIRE

    Lawrence, Jonathan

    2002-01-01

    Differences in the beam interaction characteristics of a CO2 laser, a Nd:YAG laser, a high power diode laser (HPDL) and an excimer laser with a partially stabilised zirconia (PSZ) bio-ceramic have been studied. A derivative of Beer-Lambert’s law was applied and the laser beam absorption lengths of the four lasers were calculated as 33.55 x 10-3 cm for the CO2 laser, 18.22 x 10-3 cm for the Nd:YAG laser, 17.17 x 10-3 cm for the HPDL and 8.41 x 10-6 cm for the excimer laser. It was determined g...

  11. A quencher-free molecular beacon design based on pyrene excimer fluorescence using pyrene-labeled UNA (unlocked nucleic acid)

    DEFF Research Database (Denmark)

    Karlsen, Kasper Kannegård; Okholm, Anders Hauge; Kjems, Jørgen

    2013-01-01

    A quencher-free molecular beacon capable of generating pyrene excimer fluorescence has been constructed using strategically positioned pyrene-UNA monomers. Hybridization of a fully complementary RNA target was accompanied by a pyrene excimer emission increase of more than 900%, and detection of R...... in living cells was demonstrated....

  12. A quencher-free molecular beacon design based on pyrene excimer fluorescence using pyrene-labeled UNA (unlocked nucleic acid)

    DEFF Research Database (Denmark)

    Karlsen, Kasper Kannegård; Okholm, Anders Hauge; Kjems, Jørgen

    2013-01-01

    A quencher-free molecular beacon capable of generating pyrene excimer fluorescence has been constructed using strategically positioned pyrene-UNA monomers. Hybridization of a fully complementary RNA target was accompanied by a pyrene excimer emission increase of more than 900%, and detection of RNA...

  13. Lasers in endodontics: an overview

    Science.gov (United States)

    Frentzen, Matthias; Braun, Andreas; Koort, Hans J.

    2002-06-01

    The interest in endodontic use of dental laser systems is increasing. Developing laser technology and a better understanding of laser effects widened the spectrum of possible endodontic indications. Various laser systems including excimer-, argon+-, diode-, Nd:YAG-, Er:YAG- and CO2-lasers are used in pulp diagnosis, treatment of hypersensitivity, pulp capping, sterilization of root canals, root canal shaping and obturation or apicoectomy. With the development of new delivery systems - thin and flexible fibers - for many different wavelengths laser applications in endodontics may increase. Since laser devices are still relatively costly, access to them is limited. Most of the clinical applications are laser assisted procedures such as the removing of pulp remnants and debris or disinfection of infected root canals. The essential question is whether a laser can provide improved treatment over conventional care. To perform laser therapy in endodontics today different laser types with adopted wavelengths and pulse widths are needed, each specific to a particular application. Looking into the future we will need endodontic laser equipment providing optimal laser parameters for different treatment modalities. Nevertheless, the quantity of research reports from the last decade promises a genuine future for lasers in endodontics.

  14. Laser scribing of polycrystalline thin films

    Science.gov (United States)

    Compaan, A. D.; Matulionis, I.; Nakade, S.

    2000-07-01

    We have investigated the use of several different types of lasers for scribing of the polycrystalline materials used for thin-film solar cells: CdTe, CuInGaSe 2 (CIGS), ZnO, SnO 2, Mo, Al, and Au. The lasers included four different neodymium-yttrium-aluminum garnet (Nd:YAG) (both 1064 and 532 nm wavelengths), a Cu vapor (511/578 nm), an XeCl excimer (308 nm), and a KrF excimer (248 nm). Pulse durations ranged from ˜0.1 to ˜250 ns. We found that the fundamental and frequency-doubled wavelengths of the Nd:YAG systems work well for almost all of the above materials except for the transparent conductor ZnO. The diode-laser-pumped Nd:YAG was particularly convenient to use. For ZnO the uv wavelengths of the two excimer lasers produced good results. Pulse duration was found generally not to be critical except for the case of CIGS on Mo where longer pulse durations (≥250 ns) are advantageous. The frequently observed problem of ridge formation along the edges of scribe lines in the semiconductor films can be eliminated by control of intensity gradients at the film through adjustment of the focus conditions.

  15. Laser ablation threshold of cultural heritage metals

    Science.gov (United States)

    Lorusso, A.; Nassisi, V.; Buccolieri, A.; Buccolieri, G.; Castellano, A.; Leo, L. S.; di Giulio, M.; Torrisi, L.; Caridi, F.; Borrielli, A.

    The present work has the purpose to evaluate experimentally the ablation threshold fluences of copper, silver, and their alloys in order to induce a safety laser cleaning of the metal artifacts avoiding damages to the bulkE We used two different pulsed lasers: a KrF excimer laser operating at 248 nm, 23 ns pulse duration and a Nd:YAG laser operating at 532 nm (second harmonic), 3 ns pulse. Preliminary experimental results about the laser cleaning of bronze coins will be reported. The laser cleaning consists on the reduction of the chlorine concentration from the surface of the coins. The laser cleaning, carried out by the KrF laser, provides a safe way of removing the chlorine concentration as the Energy Dispersive X-Ray Fluorescence analyses will demonstrate.

  16. Selective laser cleaning of chlorine on ancient coins

    Science.gov (United States)

    Aiello, Domenico; Buccolieri, Alessandro; Buccolieri, Giovanni; Castellano, Alfredo; Di Giulio, Massimo; Leo, Laura Sandra; Lorusso, Antonella; Nassisi, Gloria; Nassisi, Vincenzo; Torrisi, Lorenzo

    2007-05-01

    Results about the efficiency of the laser cleaning on the reduction of corrosion products from the surface of ancient coins are reported. In this work an ancient copper coin datable from 1500 to 1600 A.D. and a UV excimer laser were utilized. The goal of this work consists to study the potentiality of UV laser treatment in the reduction of the chlorine concentration on the coin surface which is the main responsible of the corrosion processes of the ancient coins. We used Energy Dispersive X-Ray Fluorescence (EDXRF) and X-Ray Diffraction (XRD) techniques to estimate the chemical composition of the coin surface, before and after UV excimer laser cleaning. In particular, we measured the chlorine, copper and calcium concentrations. We found that a radiation dose of about 19 J/cm2 was able to reduce the chlorine concentration from 2.3 % w/w to 0.6 % w/w without damaging the metal bulk.

  17. Unique effects of the chain lengths and anions of tetra-alkylammonium salts on quenching pyrene excimer.

    Science.gov (United States)

    Jang, Hyun-Sook; Zhao, Jing; Lei, Yu; Nieh, Mu-Ping

    2014-09-10

    Pyrene (Py) excimer, through its unique fluorescence quenching, exhibits high sensitivity and high selectivity in detecting specific electron-deficient molecules, providing a potential platform for sensing technology, optical switch, and probing hydrophobicity of molecular environment. In solution state, its quenching mechanism has been well-studied. However, there remain many unknown properties regarding the quenching mechanism of the solid-state Py excimer. In this paper, the effects of a series of tetra-alkylammonium salts (with a variety of chain lengths and anions) on Py excimer quenching are investigated to identify the controlling parameters of the fluorescence quenching in the binary system. Several experimental approaches including steady-state fluorescence spectroscopy, UV absorption, (13)C-nuclear magnetic resonance (NMR) spectra, X-ray diffraction, scanning electron microscopy, and time-dependent fluorescence decay are employed to seek for the fundamental understanding of the quenching mechanism. The result indicates a unique quenching effect of tetrabutylammonium cation on the pyrene excimer, and which is not observed in the other cations with different chain lengths (the same associated hexafluorophosphate anions). Meanwhile, hexafluorophosphate anion (in the presence of tetrabutylammonium) is able to effectively retain Py excimer fluorescence when the system is prepared by evaporating solvent at high temperature. It is also confirmed that dynamic quenching is involved in the process. Hydrophobic environment around Py molecules shows strong correlation with the formation of Py excimer. The knowledge obtained in this study provides the insights to how the interaction between salt and Py molecule affects the excimer fluorescence.

  18. Spectroscopic study of laser irradiated chromatin

    Science.gov (United States)

    Radu, Liliana; Mihailescu, I.; Gazdaru, Doina; Preoteasa, V.

    2013-04-01

    The effects of three UV excimer laser radiations, with wavelengths of 193, 248 and 282 nm respectively, on the structure of chromatin (the complex of deoxyribonucleic acid with proteins that exists in eukaryotic cells nuclei) were investigated. The chromatin was extracted from livers of Winstar rats. The spectroscopic methods used are: fluorescence (Förster) resonance energy transfer (FRET), time resolved fluorescence and steady-state fluorescence. A chromatin deoxyribonucleic acid radiolysis, a chromatin proteins damage and a change of the global chromatin structure on lasers action were indicated by this study. It exists some small differences between the actions of these three laser radiations.

  19. Spectroscopic study of laser irradiated chromatin

    Energy Technology Data Exchange (ETDEWEB)

    Radu, Liliana, E-mail: liliana1radu@gmail.com [V. Babes National Institute, Department of Molecular Genetics and Radiobiology (Romania); Mihailescu, I. [National Institute for Lasers, Plasma and Radiation Physics, Department of Lasers (Romania); Gazdaru, Doina [Faculty of Physics, Bucharest University, Department of Biophysics (Romania); Preoteasa, V. [V. Babes National Institute, Department of Molecular Genetics and Radiobiology (Romania)

    2013-04-15

    The effects of three UV excimer laser radiations, with wavelengths of 193, 248 and 282 nm respectively, on the structure of chromatin (the complex of deoxyribonucleic acid with proteins that exists in eukaryotic cells nuclei) were investigated. The chromatin was extracted from livers of Winstar rats. The spectroscopic methods used are: fluorescence (Foerster) resonance energy transfer (FRET), time resolved fluorescence and steady-state fluorescence. A chromatin deoxyribonucleic acid radiolysis, a chromatin proteins damage and a change of the global chromatin structure on lasers action were indicated by this study. It exists some small differences between the actions of these three laser radiations.

  20. Pustular Palmoplantar Psoriasis Successfully Treated with Nb-UVB Monochromatic Excimer Light: A Case-Report

    Directory of Open Access Journals (Sweden)

    Serena Gianfaldoni

    2017-07-01

    Full Text Available Barber’s palmoplantar pustulosis (PPP is a form of localised pustular psoriasis, affecting the palmar and plantar surfaces. It is a chronic disease, with a deep impact on the patients’ quality of life. The Authors discuss a case of Baber Psoriasis successfully treated with monochromatic excimer light.

  1. Long Coherence Length 193 nm Laser for High-Resolution Nano-Fabrication

    Science.gov (United States)

    2008-06-27

    ArF excimer lasers . In this Phase I STTR we have successfully designed and modeled a solid-state laser source that exceeds our target specifications...briefly in section 6. More details of the fiber modeling and analysis work are given in the appendix. The solid-state196 nm laser system is discussed...will limit the pulse energy . Efficiency of the system is another potential problem, as is scalability in power. A third system would use a 946 nm

  2. Novel laser ion sources

    CERN Document Server

    Fournier, P; Kugler, H; Lisi, N; Scrivens, R; Rodríguez, F V; Düsterer, S; Sauerbrey, R; Schillinger, H; Theobald, W; Veisz, L; Tisch, J W G; Smith, R A

    2000-01-01

    Development in the field of high-power laser systems with repetition rates of several Hz and energies of few joules is highly active and opening, giving new possibilities for the design of laser ions sources. Preliminary investigations on the use of four different laser and target configurations are presented: (1) A small CO/sub 2/ laser (100 mJ, 10.6 mu m) focused onto a polyethylene target to produce C ions at 1 Hz repetition rate (CERN). (2) An excimer XeCl laser (6 J, 308 nm) focused onto solid targets (Frascati). (3) A femtosecond Ti: sapphire laser (250 mJ, 800 nm) directed onto a solid targets (Jena). (4) A picosecond Nd: yttrium-aluminum-garnet (0.3 J, 532 nm) focused into a dense medium of atomic clusters and onto solid targets (London). The preliminary experimental results and the most promising schemes will be discussed with respect to the scaling of the production of high numbers of highly charged ions. Different lasers are compared in terms of current density at 1 m distance for each charge state...

  3. DUV high power lasers processing for glass and CFRP

    Science.gov (United States)

    Kobayashi, Masakazu; Kakizaki, Kouji; Oizumi, Hiroaki; Mimura, Toshio; Fujimoto, Junichi; Mizoguchi, Hakaru

    2017-05-01

    A laser processing is widely applied to cutting, drilling, welding, bending and surface treatment in industry. Lasers with a wavelength of 1 μm are mainly used and the processing is realized by melting materials. This thermal process has a high productivity but the processed surface is hard to use for precision machining. This report is focusing on two materials which are classified in wide band gap. Ablation rate was measured with a laser microscope and an optical one. Excimer laser is expected to be a useful tool for these materials

  4. [Subjective visual perception after laser treatment of myopia on two types of lasers].

    Science.gov (United States)

    Kyprianou, G; Machácková, M; Feuermannová, A; Rozsíval, P; Langrová, H

    2010-11-01

    Comparison of subjective evaluation of patients with low and moderate myopia undergoing photorefractive keratectomy (PRK) and Laser in Situ Keratomileusis (LASIK) on two types of excimer lasers: Schwind Esiris and Schwind Amaris. Patients were divided into two groups according to the type of laser that was used. Group A comprised of 23 patients (14 females, 9 males) of average age 33.1 years (range 21-51 years), with an average spherical equivalent before operation of -3.5D. Using the excimer laser Esiris (Schwind, Germany), 10 patients had undergone PRK and 13 LASIK. Group B comprised of 32 patients (21 females, 11 males), of average age 31.9 years (range 22-48 years). Median spherical equivalent before operation was -3.05D. With the excimer laser Amaris (Schwind, Germany) 17 patients had undergone PRK and 15 LASIK. For the subjective evaluation we set up a questioner consisting of 21 questions that were aimed on the quality of vision under various illumination types and intensities, vision under various distances, activities and also questions concerning superficial sensitivity of the anterior segment of the eye. We detected a 100% satisfaction one year after refractive laser treatment with both laser types. Statistical improvement was evident by one month after treatment in both patient groups and upto 12 months it progressively increased. Statistically significant differences were noted one month after treatment, where patients in group B were more satisfied in questions concerning quality of vision, distance vision, while watching TV and driving during daytime and during the night. During further follow-up, results were comparable between both groups. Temporary patient satisfaction treated with laser Amaris is apparently due to the result of a more sparing treatment and thus fewer changes in the corneal stroma.

  5. Discharge instabilities in high-pressure helium-fluorine laser gas mixtures

    NARCIS (Netherlands)

    Mathew, D.; Bastiaens, Hubertus M.J.; Peters, P.J.M.; Boller, Klaus J.

    2005-01-01

    Discharge instabilities in F2 based excimer gas lasers are investigated using a small-scale discharge system. After preionizing the gas volume, a fast rising voltage pulse initiates the discharge. The temporal development of the discharge is monitored via its fluorescence by an intensified CCD

  6. Luminescence quenching of the triplet excimer state by air traces in gaseous argon

    Science.gov (United States)

    Amsler, C.; Boccone, V.; Büchler, A.; Chandrasekharan, R.; Regenfus, C.; Rochet, J.

    2008-02-01

    The influence of air contamination on the VUV scintillation yield in gaseous argon at atmospheric pressure is investigated. We determine with a radioactive α-source the photon yield for various partial air pressures and different reflectors and wavelength shifters. We find that the time constant of the slow scintillation component depends on gas purity and is a good indicator for the total VUV light yield, while the fast component is not affected. This dependence is attributed to impurities destroying the long-lived triplet argon excimer state. The population ratio between the slow and the fast decaying excimer states is determined for α-particles to be 5.5 ± 0.6 in argon gas at 1100 mbar and room temperature. The measured decay time constant of the slow component is 3.140 ± 0.067 μs at a partial air pressure of 2 × 10-6 mbar.

  7. Luminescence quenching of the triplet excimer state by air traces in gaseous argon

    Energy Technology Data Exchange (ETDEWEB)

    Amsler, C; Boccone, V; Buechler, A; Regenfus, C; Rochet, J [Physik-Institut der Universitaet Zuerich, Winterthurerstrasse 190, CH-8057 Zuerich (Switzerland); Chandrasekharan, R [Institute for Particle Physics, ETH-Zuerich, CH-8093 Zuerich (Switzerland)], E-mail: Claude.Amsler@cern.ch

    2008-02-15

    The influence of air contamination on the VUV scintillation yield in gaseous argon at atmospheric pressure is investigated. We determine with a radioactive {alpha}-source the photon yield for various partial air pressures and different reflectors and wavelength shifters. We find that the time constant of the slow scintillation component depends on gas purity and is a good indicator for the total VUV light yield, while the fast component is not affected. This dependence is attributed to impurities destroying the long-lived triplet argon excimer state. The population ratio between the slow and the fast decaying excimer states is determined for {alpha}-particles to be 5.5 {+-} 0.6 in argon gas at 1100 mbar and room temperature. The measured decay time constant of the slow component is 3.140 {+-} 0.067 {mu}s at a partial air pressure of 2 x 10{sup -6} mbar.

  8. Temporal fluctuations in excimer-like interactions between pi-conjugated chromophores

    CERN Document Server

    Stangl, Thomas; Schmitz, Daniela; Remmerssen, Klaas; Henzel, Sebastian; Hoeger, Sigurd; Vogelsang, Jan; Lupton, John M

    2015-01-01

    Inter- or intramolecular coupling processes between chromophores such as excimer formation or H- and J-aggregation are crucial to describing the photophysics of closely packed films of conjugated polymers. Such coupling is highly distance dependent, and should be sensitive to both fluctuations in the spacing between chromophores as well as the actual position on the chromophore where the exciton localizes. Single-molecule spectroscopy reveals these intrinsic fluctuations in well-defined bi-chromophoric model systems of cofacial oligomers. Signatures of interchromophoric interactions in the excited state - spectral red-shifting and broadening, and a slowing of photoluminescence decay - correlate with each other but scatter strongly between single molecules, implying an extraordinary distribution in coupling strengths. Furthermore, these excimer-like spectral fingerprints vary with time, revealing intrinsic dynamics in the coupling strength within one single dimer molecule, which constitutes the starting point ...

  9. High efficiency fluorescent excimer lamps: An alternative to mercury based UVC lamps

    Science.gov (United States)

    Masoud, N. M.; Murnick, D. E.

    2013-12-01

    A high efficiency xenon excimer lamp radiating at 172 nm, with an internal phosphor coating shifting to UVC has been demonstrated, showing the feasibility of a cost effective alternative to UVC mercury lamps. Fluorescent lamps so designed can be fabricated in various geometries with high efficiency. Unlike other xenon excimer lamps based on dielectric barrier discharges this new system is highly compatible with existing and proposed phosphors as it operates in an inert gas environment at modest temperature and is subject only to 172 nm primary radiation. Using a lamp coated with a UVC phosphor we have demonstrated the feasibility of germicidal and curing lamps with 40% energy conversion efficiency and high power density. These lamps are rapidly switchable, have long projected lifetimes and are compatible with dimmers.

  10. High efficiency fluorescent excimer lamps: An alternative to mercury based UVC lamps

    Energy Technology Data Exchange (ETDEWEB)

    Masoud, N. M. [UV Solutions Inc, Newark, New Jersey 07103 (United States); Physics and Chemistry Department, Milwaukee School of Engineering, Milwaukee, Wisconsin 53202 (United States); Murnick, D. E. [UV Solutions Inc, Newark, New Jersey 07103 (United States); Department of Physics, Rutgers University, Newark, New Jersey 07102 (United States)

    2013-12-15

    A high efficiency xenon excimer lamp radiating at 172 nm, with an internal phosphor coating shifting to UVC has been demonstrated, showing the feasibility of a cost effective alternative to UVC mercury lamps. Fluorescent lamps so designed can be fabricated in various geometries with high efficiency. Unlike other xenon excimer lamps based on dielectric barrier discharges this new system is highly compatible with existing and proposed phosphors as it operates in an inert gas environment at modest temperature and is subject only to 172 nm primary radiation. Using a lamp coated with a UVC phosphor we have demonstrated the feasibility of germicidal and curing lamps with 40% energy conversion efficiency and high power density. These lamps are rapidly switchable, have long projected lifetimes and are compatible with dimmers.

  11. One-dimensional modelling of DBDs in NeXe mixtures for excimer lamps

    OpenAIRE

    Belasri, A; Khodja, K; Bendella, S; Harrache, Z

    2010-01-01

    Abstract Dielectric barrier discharges (DBDs) are a promising technology for high-intensity sources of specific UV and VUV radiation. In this work, the microdischarge dynamics in DBDs for Ne?Xe mixtures under the close conditions of excimer lamp working has been investigated. The computer model including the cathode fall, the positive column and the dielectric is composed of two coupled sub-models. The first submodel describes the electrical properties of the discharge and is based on a fl...

  12. Pulsed laser deposition of rare earth compounds

    CERN Document Server

    Stone, L A

    2001-01-01

    Magnetostrictive thin films have been deposited using various techniques such as sputtering and evaporation but the use of laser deposition has been limited. This research presents the results from pulsed laser deposition (PLD) of TbFe sub 2 , DyFe sub 2 and Terfenol-D thin films using an infra red Transversely Excited Atmospheric (TEA) CO sub 2 laser at lambda approx 10.6 mu m and an ultra violet Argon-Fluoride (ArF) excimer laser at lambda approx 193 nm. Results have showed that the TEA CO sub 2 laser under the range of conditions studied is not suitable for the production of magnetostrictive films. The problems experienced are a mixture of mostly fracture debris at low fluences (F approx 20 Jcm sup - sup 2) and melt droplets at high fluences (F approx 60 Jcm sup - sup 2). In all cases the destruction of the target is a major problem, with the Terfenol-D targets being the worst affected. Thin films produced were all iron rich. The use of an excimer laser has proved more successful in providing stoichiometri...

  13. Matrix assisted pulsed laser evaporation processing of triacetate-pullulan polysaccharide thin films for drug delivery systems

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, R. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor, P.O. Box MG-36, RO-077125, Bucharest-Magurele (Romania) and Institute of Physics, Academy of Sciences of Czech Republic, Na Slovance 2, 182 21 Prague 8 (Czech Republic)]. E-mail: rodica.cristescu@inflpr.ro; Dorcioman, G. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor, P.O. Box MG-36, RO-077125, Bucharest-Magurele (Romania); Ristoscu, C. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor, P.O. Box MG-36, RO-077125, Bucharest-Magurele (Romania); Axente, E. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor, P.O. Box MG-36, RO-077125, Bucharest-Magurele (Romania); Grigorescu, S. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor, P.O. Box MG-36, RO-077125, Bucharest-Magurele (Romania); Moldovan, A. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor, P.O. Box MG-36, RO-077125, Bucharest-Magurele (Romania); Mihailescu, I.N. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor, P.O. Box MG-36, RO-077125, Bucharest-Magurele (Romania); Kocourek, T. [Institute of Physics, Academy of Sciences of Czech Republic, Na Slovance 2, 182 21 Prague 8 (Czech Republic); Jelinek, M. [Institute of Physics, Academy of Sciences of Czech Republic, Na Slovance 2, 182 21 Prague 8 (Czech Republic); Albulescu, M. [National Institute for Chemical-Pharmaceutical R and D, 112 Vitan, 74373 Bucharest 3 (Romania); Buruiana, T. [Petru Poni Institute of Macromolecular Chemistry, Iasi 6600 (Romania); Mihaiescu, D. [University of Agriculture Sciences and Veterinary Medicine, 59 Marasti, Bucharest (Romania); Stamatin, I. [University of Bucharest, Faculty of Physics, P.O. Box MG-38, 3 Nano-SAE Research Center, Bucharest-Magurele (Romania); Chrisey, D.B. [US Naval Research Laboratory, Washington, DC 20375-5345 (United States)

    2006-04-30

    We report the first successful deposition of triacetate-pullulan polysaccharide thin films by matrix assisted pulsed laser evaporation. We used a KrF* excimer laser source ({lambda} = 248 nm, {tau} {approx} 20 ns) operated at a repetition rate of 10 Hz. We demonstrated by FTIR that our thin films are composed of triacetate-pullulan maintaining its chemical structure and functionality. The dependence on incident laser fluence of the induced surface morphology is analysed.

  14. Original papers A study on efficacy of 308 nm excimer light therapy in alopecia areata

    Directory of Open Access Journals (Sweden)

    Zo Nun Sanga

    2015-06-01

    Full Text Available Introduction. Alopecia areata (AA is an autoimmune condition characterized by T-cell-mediated attack on hair follicles. Objective. Evaluation of efficacy of 308 nm excimer light in the treatment of alopecia areata. Material and methods. Patches of AA were treated twice weekly, but not on 2 consecutive days, with UVB excimer 308 nm light. In all patients, half of the AA patch was irradiated and the other half was spared, covered with a black rubber shield and taken as a control. Therapy was started with an initial dose of 300 mJ/cm 2 , with an incremental dose of 100 mJ/cm 2 at every sitting until fine erythema appeared. Results. At the end of the treatment, one patient (3.33% at the test site showed > 50% hair regrowth vs. none at the control site. After a 2-month post-treatment period, successful hair regrowth (grades 3 and 4 was seen in 12 patients at test sites and in 2 patients at control sites. The differences were statistically significant (p < 0.05. After 4 months successful hair regrowth (grades 3 and 4 was seen in 16 patients at test sites and in 5 patients at control sites. The differences were statistically significant (p 0.05. Conclusions. Excimer light has the potential to stimulate hair regrowth in patches of alopecia areata.

  15. Development of laser materials processing and laser metrology techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Jung; Chung, Chin Man; Kim, Jeong Mook; Kim, Min Suk; Kim, Kwang Suk; Baik, Sung Hoon; Kim, Seong Ouk; Park, Seung Kyu

    1997-09-01

    The applications of remote laser materials processing and metrology have been investigated in nuclear industry from the beginning of laser invention because they can reduce the risks of workers in the hostile environment by remote operation. The objective of this project is the development of laser material processing and metrology techniques for repairing and inspection to improve the safety of nuclear power plants. As to repairing, we developed our own laser sleeve welding head and innovative optical laser weld monitoring techniques to control the sleeve welding process. Furthermore, we designedand fabricated a 800 W Nd:YAG and a 150 W Excimer laser systems for high power laser materials processing in nuclear industry such as cladding and decontamination. As to inspection, we developed an ESPI and a laser triangulation 3-D profile measurement system for defect detection which can complement ECT and UT inspections. We also developed a scanning laser vibrometer for remote vibration measurement of large structures and tested its performance. (author). 58 refs., 16 tabs., 137 figs.

  16. Molecule-binding dependent assembly of split aptamer and γ-cyclodextrin: A sensitive excimer signaling approach for aptamer biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Fen [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Hubei Key Laboratory of Mine Environmental Pollution Control and Remediation, Environmental Science and Engineering College, Hubei Polytechnic University, Huangshi 435003 (China); Lian, Yan; Li, Jishan; Zheng, Jing; Hu, Yaping; Liu, Jinhua; Huang, Jin [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Yang, Ronghua, E-mail: Yangrh@pku.edu.cn [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China)

    2013-10-17

    Graphical abstract: Adenosine-binding aptamer was splitted into two fragments P2 and P3 which labeled pyrene molecules, mainly produce monomer signal. γ-CD cavity brings P2 and P3 in close proximity, allowing for weak excimer emission. In the presence of target, P2 and P3 are expected to bind ATP and form an aptamer/target complex, leads to large increase of the pyrene excimer fluorescence. -- Highlights: •We assembled split aptamer and γ-cyclodextrin fluorescence biosensors for ATP detection. •The biosensor increased quantum yield and emission lifetime of the excimer. •Time-resolved fluorescence is effective for ATP assay in complicated environment. -- Abstract: A highly sensitive and selective fluorescence aptamer biosensors for the determination of adenosine triphosphate (ATP) was developed. Binding of a target with splitting aptamers labeled with pyrene molecules form stable pyrene dimer in the γ-cyclodextrin (γ-CD) cavity, yielding a strong excimer emission. We have found that inclusion of pyrene dimer in γ-cyclodextrin cavity not only exhibits additive increases in quantum yield and emission lifetime of the excimer, but also facilitates target-induced fusion of the splitting aptamers to form the aptamer/target complex. As proof-of-principle, the approach was applied to fluorescence detection of adenosine triphosphate. With an anti-ATP aptamer, the approach exhibits excimer fluorescence response toward ATP with a maximum signal-to-background ratio of 32.1 and remarkably low detection limit of 80 nM ATP in buffer solution. Moreover, due to the additive fluorescence lifetime of excimer induced by γ-cyclodextrin, time-resolved measurements could be conveniently used to detect as low as 0.5 μM ATP in blood serum quantitatively.

  17. Influence of corneal collagen crosslinking with riboflavin and ultraviolet-a irradiation on excimer laser surgery.

    NARCIS (Netherlands)

    Kampik, D.; Ralla, B.; Keller, S.; Hirschberg, M.; Friedl, P.H.A.; Geerling, G.

    2010-01-01

    PURPOSE: Riboflavin/ultraviolet A (UVA) cross-linking (CXL) of corneal collagen is a novel method of stabilizing corneal mechanical properties and preventing progression of keratectasias. This study was conducted to investigate whether CXL influences ablation rate, flap thickness, and refractive

  18. Corneal ectasia after excimer laser keratorefractive surgery: histopathology, ultrastructure, and pathophysiology.

    Science.gov (United States)

    Dawson, Daniel G; Randleman, J Bradley; Grossniklaus, Hans E; O'Brien, Terrence P; Dubovy, Sander R; Schmack, Ingo; Stulting, R Doyle; Edelhauser, Henry F

    2008-12-01

    To evaluate the histopathology and ultrastructure of corneas developing ectasia after LASIK or photorefractive keratectomy (PRK). Retrospective case series. Thirteen specimens from 12 patients undergoing corneal transplantation for progressive ectasia after LASIK (12 specimens) or PRK (1 specimen) were obtained for histopathologic and ultrastructural evaluation. All 13 ectatic corneas were submitted in formalin for light microscopy. Nine specimens were bisected, and the second half was placed in 2.5% glutaraldehyde for transmission electron microscopy (TEM). Corneal histopathology, ultrastructure, and pathophysiology. Light microscopy of the post-LASIK specimens showed corneal epithelial hypoplasia and occasional foci of epithelial hyperplasia, Bowman's layer breaks, a normal stromal thickness of the LASIK flap, a normal thickness of the hypocellular primitive stromal scar, a thinned residual stromal bed (RSB), and larger than normal artifacteous interlamellar clefts in the RSB of the ectatic region. The post-PRK specimen showed similar findings with the addition of a thinned hypercellular fibrotic stromal scar. TEM showed thinning of the collagen lamellae and loss of lamellar number in the RSB of post-LASIK ectasia corneas or throughout the entire corneal stromal bed in the post-PRK ectasia cornea, with the posterior aspect of the corneal stroma being most affected. Histopathologic and ultrastructural studies suggest that interlamellar and interfibrillar biomechanical slippage occurs when the cornea becomes ectatic after LASIK or PRK in the postoperative stress-bearing regions of the corneal stroma. This 2-phase chronic biomechanical failure process is similar to that seen in keratoconus. Composite sciences classify this chronic biomechanical failure process as interfiber fracture. The authors have no proprietary or commercial interest in any materials discussed in this article.

  19. Clinical observation on photorefractive keratectomy with epithelial removal by excimer laser

    Directory of Open Access Journals (Sweden)

    Dong-Mei Wang

    2016-03-01

    Full Text Available AIM:To investigate the clinical outcomes after photorefractive keratectomy(PRKwith epithelial removal by phototherapeutic keratectomy(PTKfor 1a. METHODS:A prospective analysis for 16 consecutive patients(30 eyeswith myopia and myopic astigmatism from July 2012 to July 2014 in our hospital underwent transepithelial photorefractive keratectomy(T-PRK, PRK with epithelial removal by PTK. Uncorrected distant visual acuity(UCVA, haze formation and remaining manifest refractive spherical equivalent(MRSEwere recorded before and at 1,3,6 and 12mo after operations. RESULTS:There were no significant differences(P>0.05in patients had an postoperative UCVA≥0.5 at 1, 3, 6 and 12mo compared with preoperative best corrected visual acuity(BCVA, and the same as the patients had an UCVA≥1.0(P>0.006. There were significant differences in haze values between different postoperative times(F=16.751, P=0.000. The haze value at 1mo was 0.71±0.25, which was gradually reduced with the time, and no more than 2 grades. Postoperative MRSE at 1mo was 0.9±0.87D, compared with 0.5±0.65D at 3mo, the difference was statistically significant(t=2.017, P=0.048. While the difference was not statistically significant(F=2.389, P=0.098among MRSE at 3, 6(0.5±0.45Dand 12mo(0.25±0.4D.CONCLUSION:The study obtained good clinical visual acuity. It shows slightly hyperopic shift and corneal haze at 1mo postoperatively. Large sample and grouped clinical research should be taken for the long-term stability of refraction and visual quality.

  20. Influence of chemical polymer composition on integrated waveguide formation induced by excimer laser surface irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hessler, S.; Rosenberger, M.; Belle, S. [Applied Laser and Photonics Group, University of Applied Sciences Aschaffenburg, Wuerzburger Strasse 45, 63743 Aschaffenburg (Germany); Schmauss, B. [Institute of Microwaves and Photonics, University of Erlangen-Nuremberg, Cauerstrasse 9, 91058 Erlangen (Germany); Hellmann, R. [Applied Laser and Photonics Group, University of Applied Sciences Aschaffenburg, Wuerzburger Strasse 45, 63743 Aschaffenburg (Germany)

    2015-11-30

    Graphical abstract: - Highlights: • Optical analysis of two different PMMA materials. • Determination of the chemical polymer compositions via {sup 1}H NMR spectroscopy. • Comparison of UV induced refractive index profiles using phase-shifting interferometry. • Optical characterization of the irradiated surface: average roughness, surface compaction. • Cut-back attenuation measurements confirm superior light guiding performance. - Abstract: We show that the chemical composition and the amount of residual monomers in polymethylmethacrylate significantly affect the evolution of optical waveguide formation induced by UV surface irradiation. We employ an interferometric approach in Mach-Zehnder configuration to determine the refractive index depth profile in different planar polymethylmethacrylate materials. Our results reveal a distinctive different surface and buried waveguide formation for materials having different monomer content. In particular, we find that for smaller residual monomer content buried waveguide formation is less pronounced, which is in turn preferential for a selective light guidance in planar polymer structures. Attenuation measurements confirm a difference in attenuation coefficient of 0.5 dB/cm.

  1. A new method of cornea modulation with excimer laser for simultaneous correction of presbyopia and ametropia.

    Science.gov (United States)

    Uthoff, Detlef; Pölzl, Markus; Hepper, Daniel; Holland, Detlef

    2012-11-01

    To investigate the outcomes of simultaneous correction of presbyopia and ametropia by a bi-aspheric cornea modulation technique, based on the creation of a central area hyperpositive for near vision and leaving the pericentral cornea for far vision in hyperopic, emmetropic, and myopic presbyopic patients. Sixty eyes of 30 patients were treated with the PresbyMAX technique by one surgeon (D.U.) at the Eye Hospital Bellevue, Kiel, Germany. Twenty eyes with hyperopic presbyopia, 20 eyes with emmetropic presbyopia, and 20 eyes with myopic presbyopia underwent Femto-Lasik, and were assessed up to 6 months postoperatively. All eyes underwent cornea treatment using the PresbyMAX® software, delivering a bi-aspheric multifocal ablation profile developed by SCHWIND eye-tech-solutions (Kleinostheim, Germany). All flaps were created by Ziemer LDV Femtolaser (Port, Switzerland). The mean binocular distance of uncorrected visual acuity (DUCVA) improved in the hyperopic group from 0.28 ± 0.29 logMAR to -0.04 ± 0.07 logMAR, in the emmetropic group from -0.05 ± 0.07 logMAR to 0.02 ± 0.11 logMAR, and in the myopic group from 0.78 ± 0.27 logMAR to 0.09 ± 0.08 logMAR. The mean binocular near uncorrected visual acuity (NUCVA) increased in the hyperopic group from 0.86 ± 0.62 logRAD to 0.24 ± 0.23 logRAD, and in the emmetropic group from 0.48 ± 0.14 logRAD to 0.18 ± 0.11 logRAD. The myopic presbyopes showed a decrease of the mean binocular NUCVA from 0.04 ± 0.19 logRAD to 0.12 ± 0.18 logRAD. The mean postoperative spherical equivalent for distance refraction was -0.13 ± 0.61 D for the hyperopic presbyopia, -0.43 ± 0.35 D for the emmetropic presbyopia, and -0.68 ± 0.42 D for the myopic presbyopia group, whereas the software took aim at -0.50 D in all groups. In presbyopic patients without symptomatic cataracts, but refractive errors, PresbyMAX® will decrease the presbyopic symptoms and correct far distance refraction in the same treatment, offering spectacle-free vision in daily life in most of the treated patients. Further investigation is necessary to evaluate the overall benefit of this procedure.

  2. Functionally gradient materials of new generation fabricated by ablation and pulsed laser deposition

    Science.gov (United States)

    Major, Boguslaw; Mroz, Waldemar; Wierzchon, Tadeusz; Ebner, Reinhold

    2003-10-01

    Physical basis of desorption and ablation are presented focusing mostly on the primary and secondary mechanisms and short pulses interaction with materials. Facilities used in pulse laser deposition (PLD) are discussed in respect to the PLD system working with an excimer laser which has been just set up at the Institute of Optoelectronics Military University of Technology. Directions of present and future applications are shown on the basis of the Proceedings of the last two Conferences on Laser Ablation COLA i.e. in Germany (1999) and Japan (2001). Own examinations on the PLD layers of FeAl and Ni3Al intermetallics produced using an excimer KrF as well as of TiN deposited by means of a Nd:YAG laser are presented.

  3. Organelle-specific injury to melanin-containing cells in human skin by pulsed laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, G.F.; Shepard, R.S.; Paul, B.S.; Menkes, A.; Anderson, R.R.; Parrish, J.A.

    1983-12-01

    Physical models predict that ultraviolet laser radiation of appropriately brief pulses can selectively alter melanin-containing cellular targets in human skin. Skin of normal human volunteers was exposed to brief (20 nanosecond) 351-nm wave length pulses from a XeF excimer laser, predicting that those cells containing the greatest quantities of melanized melanosomes (lower half of the epidermis) would be selectively damaged. Transmission electron microscopy revealed the earliest cellular alteration to be immediate disruption of melanosomes, both within melanocytes and basal keratinocytes. This disruption was dose dependent and culminated in striking degenerative changes in these cells. Superficial keratinocytes and Langerhans cells were not affected. It was concluded that the XeF excimer laser is capable of organelle-specific injury to melanosomes. These findings may have important clinical implications in the treatment of both benign and malignant pigmented lesions by laser radiations of defined wave lengths and pulse durations.

  4. Selectively deposited copper on laser-treated polyimide using electroless plating

    Science.gov (United States)

    Zhao, Gang; Phillips, Harvey M.; Zheng, HongYu; Tam, Siu Chung; Liu, Wen Qing; Wen, Gongling; Gong, Zhiben; Lam, Yee Loy

    2000-06-01

    Many reviews about the interconnection line fabrication by laser processing method were reported recently. UV laser process polyimide has been studied thoroughly during the past decade. In this report, we discussed the utilization of surface potential changing on polyimide film irradiated by excimer KrF laser and metallized the UV laser treated polyimide surface by electroless copper deposition. A new negatively charged polymer stabilized Pd solution was applied as catalyst in this experiment. We also produced pattern-wised fine line on KrF laser induced PI surface using this method.

  5. Laser Flash Photolysis of Hydrogen Peroxide to Oxidize Protein Solvent-Accessible Residues on the Microsecond Timescale

    National Research Council Canada - National Science Library

    Hambly, David M; Gross, Michael L

    2005-01-01

    ... to unfold, exposing residues that are protected in the native protein. To circumvent this possibility, we developed a method using a 248 nm KrF excimer laser to cleave hydrogen peroxide at low concentrations (15 mM, 0. 04...

  6. Evaluation of the performance of small diode pumped UV solid state (DPSS) Nd:YAG lasers as new radiation sources for atmospheric pressure laser ionization mass spectrometry (APLI-MS).

    Science.gov (United States)

    Kersten, Hendrik; Lorenz, Matthias; Brockmann, Klaus J; Benter, Thorsten

    2011-06-01

    The performance of a KrF* bench top excimer laser and a compact diode pumped UV solid state (DPSS) Nd:YAG laser as photo-ionizing source in LC-APLI MS is compared. The commonly applied bench-top excimer laser, operating at 248 nm, provides power densities of the order of low MW/cm(2) on an illuminated area of 0.5 cm(2) (8 mJ/pulse, 5 ns pulse duration, beam waist area 0.5 cm(2), 3 MW/cm(2)). The DPSS laser, operating at 266 nm, provides higher power densities, however, on a two orders of magnitude smaller illuminated area (60 μJ/pulse, 1 ns pulse duration, beam waist area 2 × 10(-3) cm(2), 30 MW/cm(2)). In a common LC-APLI MS setup with direct infusion of a 10 nM pyrene solution, the DPSS laser yields a significantly smaller ion signal (0.9%) and signal to noise ratio (1.4%) compared with the excimer laser. With respect to the determined low detection limits (LODs) for PAHs of 0.1 fmol using an excimer laser, LODs in DPSS laser LC-APLI MS in the low pmol regime are expected. The advantages of the DPSS laser with respect to applicability (size, cost, simplicity) may render this light source the preferred one for APLI applications not focusing on ultimately high sensitivities. Furthermore, the impact of adjustable ion source parameters on the performance of both laser systems is discussed in terms of the spatial sensitivity distribution described by the distribution of ion acceptance (DIA) measurements. Perspectives concerning the impact on future APLI-MS applications are given.

  7. [Results of residual ametropia correction using CIRCLE technology after femtosecond laser SMILE surgery].

    Science.gov (United States)

    Kostin, O A; Rebrikov, S V; Ovchinnikov, A I; Stepanov, A A; Takhchidi, Kh P

    to evaluate functional results of reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser in cases of regression of the refractive effect after SMILE surgery. We studied a group of post-SMILE patients. In those, who showed regression of the refractive effect at 1 year, reoperation was performed according to the CIRCLE technology and using the VisuMax femtosecond laser. The corneal flap was separated from the stromal bed and turned aside. Excimer laser ablation of the stromal bed was performed with the MEL 80 machine. The corneal flap was then placed back and rinsed from both sides. Uncorrected (UCVA) and corrected (BCVA) visual acuity as well as spherical equivalent (SE) were estimated before reoperation, on day 1, and at 1 month. After reoperation, BCVA and UCVA improved. Patient refraction became close to emmetropia. Specifically, UCVA was 0.23±0.18 at baseline (i.e. 1 year after SMILE) and 0.93±0.11 after the CIRCLE procedure (pCIRCLE, respectively (p0.05). Reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser provides an increase in visual acuity in case of post-SMILE regression of the refractive effect.

  8. Competitive Excimer Formation and Energy Transfer in Zr-Based Heterolinker Metal-Organic Frameworks.

    Science.gov (United States)

    Gutiérrez, Mario; Sánchez, Félix; Douhal, Abderrazzak

    2016-09-05

    The spectroscopy and dynamics of a series of Zr-based MOFs in dichloromethane suspension are reported. These Zr-NADC MOFs were constructed by using different mixtures of 2,6-naphthalenedicarboxylate (NDC) and 4-amino-2,6-naphthalenedicarboxylate (NADC) as organic linkers. The fraction of NADC relative to NDC in these heterolinker MOFs ranges from 2 to 35 %. The results indicate two competitive photoprocesses: NDC excimer formation and an energy transfer (ET) from excited NDC linkers to NADC linkers. Increasing the fraction of NADC linkers in the Zr-NADC nanostructure decreases the mean time constant of NDC excimer formation, while the NADC emission intensity experiences a drop at the highest fraction of this linker in the MOF. The first observation is explained by an increase in the energy-transfer probability between the two linkers, and the second by emission quenching in the NADC linkers due to ultrafast charge transfer assisted by the amino group. Femtosecond time-resolved emission studies showed that the ET process (recorded as decaying and rising components) from excited NDC to NADC takes place in 1.2 ps. Direct excitation of the NADC linkers (at 410 nm) shows a decaying, but not rising, component of 250-480 fs, which could reflect the formation of a nonemissive charge-separation state. The results show that by using MOFs having heterolinkers it is possible to trigger and tune excimer formation and ET processes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Influence of laser wavelength on two-dimensional carbon nanosheet formation from laser-induced exfoliation of naphthalene

    Science.gov (United States)

    Qian, Min; Niu, Yue Ping; Gong, Shang Qing

    2018-01-01

    Pulsed Nd:YAG (532 nm) and Excimer (248 nm) lasers were employed to produce freestanding, two-dimensional (2D), carbon nanosheets (CNSs) from naphthalene, through laser-induced exfoliation. The polymer-to-carbon transition was investigated in terms of laser wavelengths, fluences, as well as target preparations. Continuous and porous CNSs of several nanometers in thickness and micrometers in size were obtained from 532 and 248 nm pulsed laser exfoliation of spin-coated naphthalene films, respectively. The porous morphology is ascribed to the photon-induced dissociation of chemical bonds dominated in 248 nm laser interaction with ablated naphthalene. With the increase of laser fluences from 1 to 5 J cm-2, amorphous carbon and ultrathin CNS structures were obtained in sequence. This work revealed a general mechanism of producing 2D structured carbon materials from pulsed laser exfoliation.

  10. Influence of humidity on photochemical ozone generation with 172nm xenon excimer lamps

    Science.gov (United States)

    Salvermoser, M. J.; Kogelschatz, U.; Murnick, D. E.

    2009-08-01

    The reaction kinetics of photochemical ozone (O{3}) generation in humid air and oxygen (O{2}) using efficient, narrow band vacuum ultra violet (VUV) 172 nm xenon excimer lamps is discussed. Trace amounts of water (H{2}O) vapor in the process gas leads to hydroxyl (OH) and hydroperoxy (HO{2}) radical formation. These radicals drive a catalytic O{3} destruction cycle limiting O{3} saturation concentration. This catalytic O{3} destruction cycle was included into a quantitative kinetic model describing photochemical O{3} production. Experimental O{3} saturation concentrations obtained with coaxial VUV driven photochemical O{3} generators compare satisfactorily with the models predictions.

  11. High excimer-state emission of perylene bisimides and recognition of latent fingerprints.

    Science.gov (United States)

    Wang, Ke-Rang; Yang, Zi-Bo; Li, Xiao-Liu

    2015-04-07

    High excimer-state emission in the H-type aggregate of a novel asymmetric perylene bisimide derivative, 6, with triethyleneglycol chains and lactose functionalization was achieved in water. Furthermore, its application for enhancing the visualization of transfer latent fingerprints from glass slides to the poly(vinylidene fluoride) (PVDF) membrane was explored, which showed clear images of the latent fingerprint in daylight and under 365 nm ultraviolet illumination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Effect of laser pulse duration on damage to metal mirrors for laser IFE

    Science.gov (United States)

    Pulsifer, John E.; Tillack, Mark S.; Harilal, S. S.

    2008-01-01

    A Grazing Incidence Metal Mirror (GIMM) is a chief candidate for beam delivery for Inertial Fusion Energy (IFE). The goal for GIMM survival is greater than 3×10 8 laser pulses with 5 J/cm2 laser fluence normal to the incident beam. Laser-induced damage to metal mirrors is primarily a thermomechanical process. Long-term exposure leads to microstructural evolution analogous to fatigue. We have performed laser-induced damage experiments on high damage threshold aluminum mirrors using commercial KrF excimer (248 nm) lasers. We have studied mirror response to standard, 25 ns long-pulses as well as to IFE prototypic, 5 ns short-pulses achieved using a Pockels Cell. Short-pulse damage fluence was found to be better than predicted using simple thermal diffusion scaling from long-pulse results.

  13. FY 1997 report on the study on cryogenic aggregate target PLD process by multi-laser excitation for using gaseous materials; 1997 nendo chosa hokokusho (kitai genryo riyo no tame no taju laser reiki ni yoru gokuteion gyoshutai target PLD process ni kansuru kenkyu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    This paper reports the result in fiscal 1995 of the study on PLD (pulse laser deposition) thin film formation process having been made since 1993. In fiscal 1995, the effect of irradiation of excimer laser and YGA(SHG) on ablation of aggregates of N2, CH4, Ar, Kr and Xe, and the effect of time-delayed irradiation of YGA(SHG) and KrF excimer laser on ablation of N2 aggregate were studied aiming at exciting ablation by cryogenic aggregate alone. Experimental results by a newly developed multi-laser excitation experiment equipment are as follows. Ablation was not caused by KrF excimer laser irradiation, while caused by YGA(SHG) irradiation. Ablation was caused by 1mm thick N2 or CH4 aggregate alone. Kr target was the most promising among rare gas solid targets expected as seed of ablation occurrence. Multi-irradiation showed a different ablation behavior as compared with single YGA(SHG) irradiation, and in some cases, multi-irradiation not increased scattering of particles. Time-delayed multi- irradiation (YGA(SHG) excitation after excimer excitation) was effective. 23 figs., 4 tabs.

  14. Research of cornea section's shape ablated by 193-nm ArF laser spots

    Science.gov (United States)

    Zhu, Zhiqiang; Yu, Yinshan; Deng, Guoqing

    2005-11-01

    The ablation theory of cornea and biology effect by 193-nm ArF excimer laser are introduced. The ablation tracks model is put forward to make laser spots scan around cornea by many steps and many areas to change cornea curvature. The corneal average ablation curve is calculated by software so as to explain the feasibility of the ablation tracks model. By analyzing the actual ablation shapes of many arbitrary cornea sections, the optimal ablation method for deciding the random position of every laser spot in every ablation track is obtained. Experiments combining the ablation model with the device testify the energy stability of laser spots and the accuracy of rectifying anisometropia.

  15. Pressure dependence of emission intensity of rare-gas excimer light produced by silent discharge; Teikiatsu ryoiki ni okeru musei hoden reiki ki gas excimer hikari shutsuryoku no atsuryoku izonsei

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Y.; Tanaka, M.; Yukimura, K. [Doshisha University, Kyoto (Japan)

    1996-09-20

    To establish the pressure dependence of silent discharge excited rare gas excimer light emission, a vacua ultraviolet light was subjected to spectroscopic analysis at a pressure lower than 20kPa. Researches are under way to apply the discharge excited rare gas excimer lamp as a vacuum ultraviolet light source for the development of new materials and for the conservation of environments. When the pressure is as low as 1.8kPa or 4.4kPa, the emission has peaks at wavelengths centering on 147nm and 149nm, both of which are the resonance lines of the xenon atom. Excimer generation becomes prominent as the pressure increases, with the second continuum of light growing dominant at 35kPa to weaken relatively the resonance lines and the first continuum of light. In the first continuum, emission increases only at a suppressed rate, as compared with emission in the second continuum, due for instance to a collision caused relaxation process in which excimers are lost. In the case of xenon in the vicinity of 10-11kPa, the first continuum of light and the second continuum of light are approximately equal in emission intensity, producing a vacuum ultraviolet light source with a bandwidth relatively large for a single gas spectrum. 14 refs., 11 figs.

  16. Excimer fluorescence compared to depolarization in the flow cytometric characterization of lateral membrane mobility in platelets

    Science.gov (United States)

    Rothe, Gregor; Schaefer, Buerk; Wimmer, Martin S.; Schmitz, Gerd

    1998-04-01

    An altered cellular membrane fluidity secondary to changes of cholesterol metabolism is a potentially important mechanism in the pathogenesis of atherosclerosis. Especially in blood platelets an increased sensitivity for stimulation dependent aggregation which is a risk factor for thrombosis has been experimentally linked to disorders of lipid and lipoprotein metabolism. The goal of this study was the development of a flow cytometric assay for the direct analysis of cellular membrane microviscosity in correlation to activation associated phenotypic changes of platelets in vitro. The analysis of fluorescence polarization following the staining of hydrophobic lipid regions of cell membranes with the fluorescent dye 1,6-diphenyl-1,3,5-hexatriene (DPH) is a well established method for the analysis of membrane fluidity. The extent of fluorescence anisotropy dependent on the rotational mobility of this fluorochrome is indirectly proportional to the microviscosity of the stained membrane subcompartment. In this study, an alternative and more simple method based on the diffusion dependent excimer formation of pyrenedecanoic acid (PDA) (J. Immunol. Methods 96:225-31, 1987) was characterized in comparison to the DPH method as a reference. Human platelets showed a rapid uptake of both DPH and PDA resulting in the staining primarily of the plasma membrane after up to 30 min of incubation. Staining analyzed at 351 nm excitation resulted in a saturation of the depolarization coefficient of DPH at 20 (mu) M but an increase of the excimer to monomer ratio of PDA with increasing dye concentration. A 'membrane fluidity coefficient' which saturated at 5 (mu) M PDA was calculated as the excimer fluorescence divided through the square of monomer fluorescence thereby correcting for the influence of dye concentration on excimer formation. The temperature dependent changes of membrane viscosity were further used as a model for the comparison of both methods. Cells analyzed at temperatures

  17. Selective Determination of tetrabromobisphenol A by liquid chromatography following intramolecular excimer-forming fluorescence derivatization with pyrene-labeling reagent

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, H.; Tsunetomo, S.; Todoroki, K.; Nohta, H.; Yamaguchi, M. [Fukuoka Univ. (Japan); Hayama, T. [Foundation for Kyushu Environmental and Occupational Health, Kurume (Japan); Kuroki, H. [Daiichi College of Pharmaceutical Sciences, Fukuoka (Japan)

    2004-09-15

    A large number of compounds have been used as flame-retardants to protect different products from catching fire, and one of the most widely used flameretardants is tetrabromobisphenol A (TBBPA). Trace amounts of TBBPA have been determined by gas chromatography (GC) with electron-capture detection or GC-mass spectrometry (MS) as reviewed in. Only a few liquid chromatographic (LC) methods have been reported. Recently, we developed highly selective and sensitive determination methods for polyamines and dicarboxylic acids based on intramolecular excimer-forming fluorescence derivatization using pyrene reagents. By the derivatization, the resulting polypyrene-labeled derivatives of polyamines and dicarboxylic acids provided intramolecular excimer fluorescence at the wavelength region of 440 - 520 nm, which was shifted markedly to the higher emission wavelengths as compared to the wavelengths of the pyrene reagent itself and monopyrene-labeled concomitants (360 - 420 nm). This chemistry allowed to selectively analyzing poly-functional compounds even in the complex samples containing monofunctional compounds. More recently, we have found that 4-(1-pyrene)butanoyl chloride (PBC) reacts with not only polyamines, but also phenol compounds such as bisphenols, and the obtained PBC derivatives form strong intramolecular excimers. The aim of this work was to develop an intramolecular excimer-forming derivatization method for fluorimetric determination of halogenated-bisphenols including TBBPA following their derivatization with PBC. The new method allows a highly sensitive and selective determination of tetrabromobisphenol A.

  18. Lasers in clinical ophthalmology

    Science.gov (United States)

    Ribeiro, Paulo A.

    1992-03-01

    The clinical application of lasers in ophthalmology is schematized, showing for each anatomic eye structure, pathologies that may be treated through this procedure. In the cornea, the unusual laser practice for suture removals and the promising possibility of the excimer laser in refractive surgery are discussed. In the iris, the camerular angle, and the ciliary body, the laser application is essentially used to treat the glaucoma and other situations that are not so frequent. The capsulotomy with YAG LASER is used in the treatment of structures related with crystalline and, at least, the treatment of the retina and choroid pathology is expanded. A. A. explained the primordial interest and important of laser in the diabetic retinopathy treatment and some results in patients with more than 5 years of evolution are: 55 of the patients with proliferative diabetic retinopathy (RDP) treated for more than 5 years noticed their vision improved or stabilized; 5 years after treating patients with PDR, 49.3 had their vision stabilized or even improved, provided the diabetics had declared itself more than 20 years ago, versus 61.7 provided the diabetics had declared itself less than 20 years before; finally, 53.8 of the patients under 40-years-old when the diabetics was diagnosed, had their vision improved or at least stabilized 5 years after the beginning of the treatment. On the other side, when patients were over 40 years old when the diabetics was diagnosed percentage increased to 55.9. This study was established in the follow-up of 149 cases over 10 years.

  19. Comparative study on Pulsed Laser Deposition and Matrix Assisted Pulsed Laser Evaporation of urease thin films

    Energy Technology Data Exchange (ETDEWEB)

    Smausz, Tomi, E-mail: tomi@physx.u-szeged.h [Department of Optics and Quantum Electronics, University of Szeged, H-6701 Szeged, P.O. Box 406 (Hungary); Megyeri, Gabor; Kekesi, Renata; Vass, Csaba [Department of Optics and Quantum Electronics, University of Szeged, H-6701 Szeged, P.O. Box 406 (Hungary); Gyoergy, Eniko; Sima, Felix; Mihailescu, Ion N. [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, PO Box MG-54, RO-77125, Bucharest-Magurele (Romania); Hopp, Bela [Hungarian Academy of Sciences and University of Szeged, Research Group on Laser Physics, H-6701 Szeged, P.O. Box 406 (Hungary)

    2009-06-01

    Urease thin films were produced by Matrix Assisted Pulsed Laser Evaporation (MAPLE) and Pulsed Laser Deposition from two types of targets: frozen water solutions of urease with different concentrations (1-10% m/v) and pure urease pellets. The fluence of the ablating KrF excimer laser was varied between 300 and 2200 mJ/cm{sup 2}. Fourier transform infrared spectra of the deposited films showed no difference as compared to the original urease. Morphologic studies proved that the films consist of a smooth 'base' layer with embedded micrometer-sized droplets. Absorption-coefficient measurements contradicted the traditional 'absorptive matrix' model for MAPLE deposition. The laser energy was absorbed by urease clusters leading to a local heating-up and evaporation of the frozen matrix from the uppermost layer accompanied by the release of dissolved urease molecules. Significant enzymatic activity of urease was preserved only during matrix assisted transfer.

  20. Photodynamic Therapy With YAG-OPO Laser for Early Stage Lung Cancer.

    Science.gov (United States)

    Kato, H; Okunaka, T; Konaka, C; Furuse, K; Kusunoki, Y; Horai, T; Takifuji, N; Negoro, S; Fukuoka, M; Yaya, T; Kawase, I

    1997-01-01

    Photodynamic therapy (PDT) utilizing Photofrin is proving to be effective for the treatment of early stage lung cancers. The effect of PDT utilizing YAG-OPO laser as new light source was evaluated in 26 patients (29 lesions) with early stage lung cancers. YAG-OPO laser is solid state tunable laser which is easy to change wavelength between 620 and 670 nm exciting various kinds of photosensitizers. Moreover, YAG-OPO laser is more reliable, smaller and has less consumables than argon-dye laser or excimer-dye laser. As the result of PDT with YAG-OPO laser, complete remission (CR) was obtained in 82.6% of the 29 lesions, partial remission (PR) in 13.8% and no change (NC) was obtained in 3.4%. We conclude that PDT utilizing YAG-OPO laser is efficacious in the treatment of early stage lung cancers and can achieve complete remission.

  1. Photodynamic Therapy With YAG-OPO Laser for Early Stage Lung Cancer

    Directory of Open Access Journals (Sweden)

    Harubumi Kato

    1997-01-01

    Full Text Available Photodynamic therapy (PDT utilizing Photofrin is proving to be effective for the treatment of early stage lung cancers. The effect of PDT utilizing YAG-OPO laser as new light source was evaluated in 26 patients (29 lesions with early stage lung cancers. YAG-OPO laser is solid state tunable laser which is easy to change wavelength between 620 and 670 nm exciting various kinds of photosensitizers. Moreover, YAG-OPO laser is more reliable, smaller and has less consumables than argon-dye laser or excimer-dye laser. As the result of PDT with YAG-OPO laser, complete remission (CR was obtained in 82.6% of the 29 lesions, partial remission (PR in 13.8% and no change (NC was obtained in 3.4%. We conclude that PDT utilizing YAG-OPO laser is efficacious in the treatment of early stage lung cancers and can achieve complete remission.

  2. High frequency excitation waveform for efficient operation of a xenon excimer dielectric barrier discharge lamp

    Science.gov (United States)

    Beleznai, Sz; Mihajlik, G.; Maros, I.; Balázs, L.; Richter, P.

    2010-01-01

    The application of a high frequency (~2.5 MHz) burst (amplitude-modulated sinusoidal) excitation voltage waveform is investigated for driving a fluorescent dielectric barrier discharge (DBD) light source. The excitation waveform presents a novel method for generating spatially stable homogeneous Xe DBD possessing a high conversion efficiency from electrical energy to VUV Xe_{2}^{\\ast} excimer radiation (~172 nm), even at a significantly higher electrical energy deposition than realized by pulsed excitation. Simulation and experimental results predict discharge efficiencies around 60%. Lamp efficacy above 74 lm W-1 has been achieved. VUV emission and loss mechanisms are investigated extensively and the performance of burst and pulsed waveforms is compared both theoretically and experimentally.

  3. High frequency excitation waveform for efficient operation of a xenon excimer dielectric barrier discharge lamp

    Energy Technology Data Exchange (ETDEWEB)

    Beleznai, Sz; Mihajlik, G; Richter, P [Department of Atomic Physics, Budapest University of Technology and Economics, 3-9.Muegyetem rkp., Budapest H-1111 (Hungary); Maros, I; Balazs, L, E-mail: beleznai@dept.phy.bme.h [GE Consumer and Industrial-Lighting, 77 Vaci ut, Budapest H-1344 (Hungary)

    2010-01-13

    The application of a high frequency ({approx}2.5 MHz) burst (amplitude-modulated sinusoidal) excitation voltage waveform is investigated for driving a fluorescent dielectric barrier discharge (DBD) light source. The excitation waveform presents a novel method for generating spatially stable homogeneous Xe DBD possessing a high conversion efficiency from electrical energy to VUV Xe{sub 2}{sup *} excimer radiation ({approx}172 nm), even at a significantly higher electrical energy deposition than realized by pulsed excitation. Simulation and experimental results predict discharge efficiencies around 60%. Lamp efficacy above 74 lm W{sup -1} has been achieved. VUV emission and loss mechanisms are investigated extensively and the performance of burst and pulsed waveforms is compared both theoretically and experimentally.

  4. Intramolecular photoassociation and photoinduced charge transfer in bridged diaryl compounds. 4. Temporal studies of intramolecular triplet excimer formation in dinaphthylmethanes and dinaphthyl ethers

    Energy Technology Data Exchange (ETDEWEB)

    Modiano, S.H.; Dresner, J.; Cai, J.; Lim, E.C. (Univ. of Akron, OH (United States))

    1993-04-08

    Comparisons of the temporal characteristics of the transient absorption with those of the delayed fluorescence for dinaphthylmethanes and dinaphthyl ethers provide compelling kinetic evidence for the formation of intramolecular triplet excimers. 7 refs., 7 figs., 1 tab.

  5. Functional polyethylene glycol derivatives nanostructured thin films synthesized by matrix-assisted pulsed laser evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, R., E-mail: rodica.cristescu@inflpr.ro [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, Bucharest-Magurele (Romania); Popescu, C.; Popescu, A.; Grigorescu, S.; Mihailescu, I.N. [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, Bucharest-Magurele (Romania); Mihaiescu, D. [University of Agriculture Sciences and Veterinary Medicine, 59 Marasti, Bucharest (Romania); Gittard, S.D.; Narayan, R.J. [Biomedical Engineering, University of North Carolina, Chapel Hill, NC (United States); Buruiana, T. [Petru Poni Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda, 41A, Iasi (Romania); Stamatin, I. [University of Bucharest, 3Nano-SAE Research Center, PO Box MG-38, Bucharest-Magurele (Romania); Chrisey, D.B. [Rensselaer Polytechnic Institute, Department of Materials Science and Engineering, Troy, NY (United States)

    2009-09-30

    We report the thin film deposition by matrix-assisted pulsed laser evaporation (MAPLE) of a polymer conjugate with an hydrophilic sequence between metronidazole molecules that was covalently attached to both oligomer ends of carboxylate poly(ethylene glycol) (PEG 1.5-metronidazole). A pulsed KrF* excimer laser was used to deposit the drug-polymer composite films. Fourier transform infrared spectroscopy was used to demonstrate that MAPLE-transferred materials exhibited chemical properties similar to the starting materials. The dependence of the surface morphology on incident laser fluence is given.

  6. Synthesis of ferromagnetic Bi-substituted yttrium iron garnet films by laser ablation

    OpenAIRE

    Kidoh, Hideo; Morimoto, Akiharu; Shimizu, Tastuo

    1991-01-01

    Bismuth‐substituted yttrium iron garnet (Bi:YIG) films were deposited on gadolinium gallium garnet substrate by laser ablation using the ArF excimer laser. This is the first report on the preparation of Bi‐substituted YIG films by laser ablation. Films have a garnet single phase above the substrate temperature of 490 °C, and the film composition does not deviate largely from the target composition and it is almost constant in the temperature range between 490 and 580 °C. The saturation magnet...

  7. Laser Recanalization of Central Venous Occlusion to Salvage a Threated Arteriovenous Fistula.

    Science.gov (United States)

    Rambhia, Sagar; Janko, Matthew; Hacker, Robert I

    2018-02-15

    Central venous occlusion is conventionally managed with balloon angioplasty, stent extension or sharp recanalization. Here we describe recanalization of a chronically occluded innominate vein using excimer laser after conventional techniques were unsuccessful. Patient clinical improvement and fistula patency have been sustained two years post-intervention. This technique may provide new hemodialysis access options for patients who would not otherwise be candidates for hemodialysis access on the ipsilateral side of a central venous occlusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Pulsed-laser-induced nanoscale island formation in thin metal-on-oxide films

    OpenAIRE

    Henley, SJ; Carey, JD; Silva, SRP

    2005-01-01

    he mechanisms controlling the nanostructuring of thin metal-on-oxide films by nanosecond pulsed excimer lasers are investigated. When permitted by the interfacial energetics, the breakup of the metal film into nanoscale islands is observed. A range of metals (Au, Ag, Mo, Ni, Ti, and Zn) with differing physical and thermodynamic properties, and differing tendencies for oxide formation, are investigated. The nature of the interfacial metal-substrate interaction, the thermal conductivity of the ...

  9. Growth of Al doped ZnO thin films by a synchronized two laser system

    Energy Technology Data Exchange (ETDEWEB)

    Gyoergy, E. [Institute of Atomic Physics, P.O. Box MG 36, 77125 Bucharest (Romania) and Consejo Superior de Investigationes Cientificas, Instituto de Ciencia de Materiales, Campus de la UAB, 08193 Bellaterra (Spain)]. E-mail: eniko@ifin.nipne.ro; Santiso, J. [Consejo Superior de Investigationes Cientificas, Instituto de Ciencia de Materiales, Campus de la UAB, 08193 Bellaterra (Spain); Giannoudakos, A. [National Hellenic Research Foundation, Theoretical and Physical Chemistry Institute, Vasileos Konstantinou Ave. 48, 11635 Athens (Greece); Kompitsas, M. [National Hellenic Research Foundation, Theoretical and Physical Chemistry Institute, Vasileos Konstantinou Ave. 48, 11635 Athens (Greece); Mihailescu, I.N. [Institute of Atomic Physics, P.O. Box MG 36, 77125 Bucharest (Romania); Pantelica, D. [National Institute for Physics and Nuclear Engineering, 76900 Bucharest (Romania)

    2005-07-30

    We report the deposition of Al doped ZnO thin films with the aid of a synchronised two laser system. The laser system consists of an ArF* excimer laser ({lambda} = 193 nm, {tau} {approx} 12 ns) and a Nd:YAG laser ({lambda} = 355 nm, {tau} {approx} 10 ns), for the time-matched ablation of the host (Zn) and dopant (Al) targets in oxygen atmosphere. Our approach allows for the independent and accurate setting of the laser fluences of the two lasers, in accordance with the energy requirements of the host and dopant materials. The method proposed by us permits also an in situ change of the doping conditions throughout the thin film growth process. The controlled modification of the dopant profile inside the growing film can be obtained relatively easily by the appropriate variation of the Nd:YAG laser fluence and/or number of pulses applied to the Al dopant target during the deposition process.

  10. Laser-induced fluorescence imaging of coronary arteries for open-heart surgery applications

    Science.gov (United States)

    Taylor, Roderick S.; Gladysz, D.; Brown, Derek W.; Higginson, Lyall A. J.

    1991-07-01

    A technique utilizing laser induced fluorescence has been developed to obtain direct real-time imaging of the coronary artery network for open heart surgery applications. Both excimer pumped dye and cw argon-ion laser radiation transmitted through a fused silica fiber were used as laser sources to irradiate swine, bovine, and human cadaver hearts whose coronary arteries had been injected with strongly fluorescent dyes. The laser induces fluorescence originating from within the coronary arteries and detected by the surgeon's eye, allows the entire coronary network to be directly viewed. A comparison between laser induced fluorescence and the use of direct visual inspection of arteries following injection of the dye Cardio-Green(R) as well as conventional thermal imaging is presented. The limitations imposed on each technique by layers of fat on top of the coronary arteries are also described. The possibility of using these techniques to detect mechanical or laser beam perforations during laser endarterectomy procedures is discussed.

  11. Charge carrier mobility and electronic properties of Al(Op3: impact of excimer formation

    Directory of Open Access Journals (Sweden)

    Andrea Magri

    2015-05-01

    Full Text Available We have studied the electronic properties and the charge carrier mobility of the organic semiconductor tris(1-oxo-1H-phenalen-9-olatealuminium(III (Al(Op3 both experimentally and theoretically. We experimentally estimated the HOMO and LUMO energy levels to be −5.93 and −3.26 eV, respectively, which were close to the corresponding calculated values. Al(Op3 was successfully evaporated onto quartz substrates and was clearly identified in the absorption spectra of both the solution and the thin film. A structured steady state fluorescence emission was detected in solution, whereas a broad, red-shifted emission was observed in the thin film. This indicates the formation of excimers in the solid state, which is crucial for the transport properties. The incorporation of Al(Op3 into organic thin film transistors (TFTs was performed in order to measure the charge carrier mobility. The experimental setup detected no electron mobility, while a hole mobility between 0.6 × 10−6 and 2.1 × 10−6 cm2·V−1·s−1 was measured. Theoretical simulations, on the other hand, predicted an electron mobility of 9.5 × 10−6 cm2·V−1·s−1 and a hole mobility of 1.4 × 10−4 cm2·V−1·s−1. The theoretical simulation for the hole mobility predicted an approximately one order of magnitude higher hole mobility than was observed in the experiment, which is considered to be in good agreement. The result for the electron mobility was, on the other hand, unexpected, as both the calculated electron mobility and chemical common sense (based on the capability of extended aromatic structures to efficiently accept and delocalize additional electrons suggest more robust electron charge transport properties. This discrepancy is explained by the excimer formation, whose inclusion in the multiscale simulation workflow is expected to bring the theoretical simulation and experiment into agreement.

  12. Choice of the laser wavelength for a herpetic keratitis treatment

    Science.gov (United States)

    Razhev, Alexander M.; Bagayev, Sergei N.; Chernikh, Valery V.; Kargapoltsev, Evgeny S.; Trunov, Alexander; Zhupikov, Andrey A.

    2002-06-01

    For the first time the effect of the UV laser radiation to human eye cornea with herpetic keratitis was experimentally investigated. In experiments the UV radiation of ArF (193 nm), KrCl (223 nm), KrF (248 nm) excimer lasers were used. Optimal laser radiation parameters for the treatment of the herpetic keratitis were determined. The immuno-biochemical investigations were carried out and the results of clinical trials are presented. The maximum ablation rate was obtained for the 248 nm radiation wavelength. The process of healing was successful but in some cases the haze on the surface of the cornea was observed. When used the 193 nm radiation wavelength the corneal surface was clear without any hazes but the epithelization process was slower than for 248 nm wavelength and in some cases the relapse was occurred. The best results for herpetic keratitis treatment have been achieved by utilizing the 223 nm radiation wavelength of the KrCl excimer laser. The use of the 223 nm radiation wavelength allows treating the herpetic keratitis with low traumatic process of ablation and provides high quality of corneal surface.

  13. Free Electron Laser Synthesis of Functional Coatings

    Science.gov (United States)

    Schaaf, Peter; Höche, Daniel

    Functional and smart surfaces and coatings play an increasingly decisive role in the applicability and performance of modern materials. From an industrial point of view, there is a great interest with respect to friction, wear, corrosion, and further properties. Many methods have been developed for the improvement of the respective surface and material properties. Traditionally, these treatments range from simple PVD and CVD processes to complicated plasma and hybrid methods. Recently, it has been established that short laser pulses of high energy can induce a direct laser synthesis of functional coatings if the material's surface is irradiated in a reactive atmosphere. The process is based on a complicated combination of laser plasma - gas - material surface interactions. Tests for steel, aluminum, magnesium, titanium, and silicon in nitrogen, methane, and hydrogen atmospheres have been carried out successfully; with these materials, interesting coatings can be produced by direct laser synthesis, for example, AlN and SiC. Various laser types can be used for this purpose: Excimer, Nd:YAG, CO2 Laser, and even the free electron laser (FEL).

  14. 3D microstructuring with F2 lasers

    Science.gov (United States)

    Toenshoff, Hans K.; von Alvensleben, Ferdinand; Ostendorf, Andreas; Koerber, Klaus; Kulik, Christian

    2000-09-01

    F2 lasers emitting radiation with a wavelength (lambda) equals 157 nm allow the direct laser based micro-structuring of materials like PTFE (e.g. Teflon) or quartz glass for MST-applications. This paper reports about the fundamental basis of controlling and modelling the structuring process and about existing tools for the 3-D micron structuring with F2 excimer lasers. The concept of three-dimensional micro-structuring is based on gradual ablation, using single laser pulses. A CNC-controlled precision machining centre with a vacuum encapsulated beam guiding system has been developed. For the material processing with F2 lasers a model of the single ablation size was qualified, which provides an exact description of the laser pulse taking the material properties, the energy density and the lateral dimensions of the single ablation into account. The non- linear characteristics between pulse geometry and process parameters were experimentally determined and implemented into software for automated NC-data generation. A special software tool makes the simulation of manufacturing micro-components possible. It is based on the complex NC-code and on the exact model of the single ablation. Using this simulation, the process parameters can be optimised before processing with a laser micro-machining centre. The described technology was verified by manufacturing 3-D micro-structures in several materials, such as quartz glass and PTFE.

  15. General machining concept for producing micro-optics with high-power UV lasers

    Science.gov (United States)

    Toenshoff, Hans K.; Overmeyer, Ludger; Ostendorf, Andreas; Wais, Johannes

    1997-03-01

    The development of new processes for the micro-treatment of material is the basis for increasing integration and miniaturization of mechanical, optical and electronic components. Pulsed high power excimer lasers offer in combination with a micro-machining system, the possibility of manufacturing highly complex components in different materials like ceramics, glass or metals, Because of the increasing number of technical applications, the need for automatic processing has grown in the last few years. While complete working stations are available for Nd:YAG and CO2 lasers, there is a lack for automatic micro-removal with excimer lasers. For complex microstructures like micro- optics, manual programming of the workpiece handling system becomes uneconomic because of the very high number of laser pulses required. Especially for prototypes and small batches where the workpiece geometries change quickly, the development of a universal and automatic machining concept plays a key role for this technology. For this reason, a general machining concept based on excimer laser removal has been realized beginning with the possibility to construct the workpiece geometry by CAD-design tools. A preprocessor allows to calculate the removal volume based on laser specific ablation volumes. The superposition of each laser pulse removal leads to complex 3D surface structures. Moreover, a general movement strategy optimizes the processing speed. For closing the process chain the realized preprocessor automatically generates the necessary NC-data for the implemented CNC-control system. Functionality of this concept has been proven by manufacturing different two and three dimensional micro-structures like micro-optical components.

  16. Efficacy of fractional lasers in treating alopecia: a literature review.

    Science.gov (United States)

    Perper, Marina; Aldahan, Adam S; Fayne, Rachel A; Emerson, Christopher P; Nouri, Keyvan

    2017-11-01

    Hair loss stemming from different types of alopecia, such as androgenic alopecia and alopecia areata, negatively affects over half the population and, in many circumstances, causes serious psychosocial distress. Current treatment options for alopecia, such as minoxidil, anthralin, and intralesional corticosteroids, vary efficacy and side effect profiles. It is known that low-level laser/light therapies (LLLT), or photobiomodulations, such as the US FDA-cleared HairMax Lasercomb®, He-Ne laser, and excimer laser, are relatively affordable, user-friendly, safe, and effective forms of treatment for hair loss. While less is known about the effectiveness of fractional lasers for combating hair loss, research suggests that by creating microscopic thermal injury zones, fractional lasers may cause an increase in hair growth from a wound healing process, making them potential therapeutic options for alopecia. A literature review was performed to evaluate the effectiveness of fractional lasers on hair regrowth. The specific fractional laser therapies include the 1550-nm nonablative fractional erbium-glass laser, the ablative fractional 2940-nm erbium:YAG laser, and the ablative fractional CO 2 fractional laser. Additional randomized controlled trials are necessary to further evaluate the effectiveness of the lasers, as well as to establish appropriate parameters and treatment intervals.

  17. Biomolecular papain thin films growth by laser techniques.

    Science.gov (United States)

    György, Enikö; Santiso, Jose; Figueras, Albert; Socol, Gabriel; Mihailescu, Ion N

    2007-08-01

    Papain thin films were synthesised by matrix assisted and conventional pulsed laser deposition (PLD) techniques. The targets submitted to laser radiation consisted on a frozen composite obtained by dissolving the biomaterials in distilled water. For the deposition of the thin films by conventional PLD pressed biomaterial powder targets were submitted to laser irradiation. An UV KrF* excimer laser source was used in the experiments at 0.5 J/cm(2) incident fluence value, diminished one order of magnitude as compared to irradiation of inorganic materials. The surface morphology of the obtained thin films was studied by atomic force profilometry and atomic force microscopy. The investigations showed that the growth mode and surface quality of the deposited biomaterial thin films is strongly influenced by the target preparation procedure.

  18. Metal surface nitriding by laser induced plasma

    Science.gov (United States)

    Thomann, A. L.; Boulmer-Leborgne, C.; Andreazza-Vignolle, C.; Andreazza, P.; Hermann, J.; Blondiaux, G.

    1996-10-01

    We study a nitriding technique of metals by means of laser induced plasma. The synthesized layers are composed of a nitrogen concentration gradient over several μm depth, and are expected to be useful for tribological applications with no adhesion problem. The nitriding method is tested on the synthesis of titanium nitride which is a well-known compound, obtained at present by many deposition and diffusion techniques. In the method of interest, a laser beam is focused on a titanium target in a nitrogen atmosphere, leading to the creation of a plasma over the metal surface. In order to understand the layer formation, it is necessary to characterize the plasma as well as the surface that it has been in contact with. Progressive nitrogen incorporation in the titanium lattice and TiN synthesis are studied by characterizing samples prepared with increasing laser shot number (100-4000). The role of the laser wavelength is also inspected by comparing layers obtained with two kinds of pulsed lasers: a transversal-excited-atmospheric-pressure-CO2 laser (λ=10.6 μm) and a XeCl excimer laser (λ=308 nm). Simulations of the target temperature rise under laser irradiation are performed, which evidence differences in the initial laser/material interaction (material heated thickness, heating time duration, etc.) depending on the laser features (wavelength and pulse time duration). Results from plasma characterization also point out that the plasma composition and propagation mode depend on the laser wavelength. Correlation of these results with those obtained from layer analyses shows at first the important role played by the plasma in the nitrogen incorporation. Its presence is necessary and allows N2 dissociation and a better energy coupling with the target. Second, it appears that the nitrogen diffusion governs the nitriding process. The study of the metal nitriding efficiency, depending on the laser used, allows us to explain the differences observed in the layer features

  19. Influence of sputtering conditions on the optical and electrical properties of laser-annealed and wet-etched room temperature sputtered ZnO:Al thin films

    Energy Technology Data Exchange (ETDEWEB)

    Boukhicha, Rym, E-mail: rym.boukhicha@polytechnique.edu [CNRS, LPICM, Ecole Polytechnique, 91128 Palaiseau (France); Charpentier, Coralie [CNRS, LPICM, Ecole Polytechnique, 91128 Palaiseau (France); Total S and M — New Energies Division, R and D Division, Department of Solar Energies EN/BO/RD/SOL, Tour Michelet, 24 cours Michelet, La Défense 10, 92069 Paris La Défense Cedex (France); Prod' Homme, Patricia [Total S and M — New Energies Division, R and D Division, Department of Solar Energies EN/BO/RD/SOL, Tour Michelet, 24 cours Michelet, La Défense 10, 92069 Paris La Défense Cedex (France); Roca i Cabarrocas, Pere [CNRS, LPICM, Ecole Polytechnique, 91128 Palaiseau (France); Lerat, Jean-François; Emeraud, Thierry [Photovoltaic Business Unit, Excico Group NV, Kempische Steenweg 305/2, B-3500 Hasselt (Belgium); Johnson, Erik [CNRS, LPICM, Ecole Polytechnique, 91128 Palaiseau (France)

    2014-03-31

    We explore the influence of the sputtering deposition conditions on the outcome of an excimer laser anneal and chemical etching process with the goal of producing highly textured substrates for thin film silicon solar cells. Aluminum-doped zinc oxide (ZnO:Al) thin films were prepared on glass substrates by radio frequency magnetron sputtering from a ceramic target at room temperature. The effects of the process pressure (0.11–1.2 Pa) and oxygen flow (0–2 sccm) on the optical and electrical properties of ZnO:Al thin films have been studied both before and after an excimer laser annealing treatment followed by a dilute HCl chemical etch. The as-deposited films varied from completely opaque to yellowish. Thin film laser annealing dramatically improves the optical properties of the most opaque thin films. After laser annealing at the optimum fluence, the average transmittance in the visible wavelength range was around 80% for most films, and reasonable electrical performance was obtained for the films deposited at lower pressures and without oxygen flux (7 Ω/□ for films of 1 μm). After etching, all films displayed a dramatic improvement in haze, but only the low pressure, low oxygen films retained acceptable electrical properties (< 11 Ω/□). - Highlights: • Al:ZnO thin films were deposited at room temperature. • The ZnO:Al films were excimer laser annealed and then wet-etched. • The optical and electrical properties were studied in details.

  20. Self-Calibrating Mechanochromic Fluorescent Polymers Based on Encapsulated Excimer-Forming Dyes.

    Science.gov (United States)

    Calvino, Céline; Guha, Anirvan; Weder, Christoph; Schrettl, Stephen

    2018-01-18

    While mechanochemical transduction principles are omnipresent in nature, mimicking these in artificial materials is challenging. The ability to reliably detect the exposure of man-made objects to mechanical forces is, however, of great interest for many applications, including structural health monitoring and tamper-proof packaging. A useful concept to achieve mechanochromic responses in polymers is the integration of microcapsules, which rupture upon deformation and release a payload causing a visually detectable response. Herein, it is reported that this approach can be used to create mechanochromic fluorescent materials that show a direct and ratiometric response to mechanical deformation. This can be achieved by filling poly(urea-formaldehyde) microcapsules with a solution of a photoluminescent aggregachromic cyano-substituted oligo(p-phenylene vinylene) and embedding these particles in poly(dimethylsiloxane). The application of mechanical force by way of impact, incision, or tensile deformation opens the microcapsules and releases the fluorophore in the damaged area. Due to excimer formation, the subsequent aggregation of the dye furnishes a detectable fluorescence color change. With the emission from unopened microcapsules as built-in reference, the approach affords materials that are self-calibrating. This new concept appears to be readily applicable to a range of polymer matrices and allows for the straightforward assessment of their structural integrity. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Photolytic degradation of organic azo dye in aqueous solution using Xe-excimer lamp.

    Science.gov (United States)

    Feng, X; Zhu, S; Hou, H

    2006-02-01

    The photodegradation of organic azo dye C.I. Food Yellow 4 (FY-4) in aqueous solution was achieved, without the addition of oxidants, by 172 nm vacuum ultraviolet (VUV) radiation emitted from the planar Xe-excimer lamp. The degradation was mainly attributed to the impact of HO radicals produced by water absorbing VUV radiation. The dye decolorization followed pseudo-first order kinetics. The initial quantum yields of FY-4 decolorization in O2-saturated solution and N2-saturated solution were respectively 0.151 +/- 0.003 and 0.103 +/- 0.002. Dissolved oxygen in the solution contributed to the increase of the decolorization rate and chemical oxygen demand (COD) removal rate while KCI added as HO radical scavenger decreased the efficiency of the decolorization and COD removal. It was found from the change of the UV-Vis spectra that the degradation of FY-4 was accompanied by both the cleavage of chromophoric group and the opening of aromatic ring. Major intermediates detected were aromatic compounds, some low molecular weight by-products and several organic acids and inorganic ions.

  2. Matrix assisted pulsed laser evaporation of pullulan tailor-made biomaterial thin films for controlled drug delivery systems

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, R [National Institute for Laser, Plasma and Radiation Physics, MG-36, RO-77125, Bucharest (Romania); Jelinek, M [Institute of Physics ASCR, Na Slovance 2, 182 21Prague 8 (Czech Republic); Kocourek, T [Institute of Physics ASCR, Na Slovance 2, 182 21Prague 8 (Czech Republic); Axente, E [National Institute for Laser, Plasma and Radiation Physics, MG-36, RO-77125, Bucharest (Romania); Grigorescu, S [National Institute for Laser, Plasma and Radiation Physics, MG-36, RO-77125, Bucharest (Romania); Moldovan, A [National Institute for Laser, Plasma and Radiation Physics, MG-36, RO-77125, Bucharest (Romania); Mihaiescu, D E [University of Agriculture Sciences and Veterinary Medicine, 59 Marasti, Bucharest (Romania); Albulescu, M [National Institute for Chemical-Pharmaceutical R and D, 112 Vitan, 74373 Bucharest 3 (Romania); Buruiana, T [Petru Poni Institute of Macromolecular Chemistry, Iasi, 6600 (Romania); Dybal, J [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovsky Sq. 2, 16206, Prague 6, Czech Republic (Czech Republic); Stamatin, I [University of Bucharest, Faculty of Physics, PO Box MG-11, 3Nano-SAE Research Center, Bucharest-Magurele (Romania); Mihailescu, I N [National Institute for Laser, Plasma and Radiation Physics, MG-36, RO-77125, Bucharest (Romania); Chrisey, D B [Naval Research Laboratory, Code 6851 Washington, DC 20375 (United States)

    2007-04-15

    We report the first successful deposition of cinnamate-pullulan polysaccharide thin films by Matrix Assisted Pulsed Laser Evaporation (MAPLE). Thin film depositions were performed in vacuum using a KrF* excimer laser source ({lambda} = 248 nm, {tau} {approx} 20 ns) operated at a repetition rate of 10 Hz. The dependence on incident laser fluence of the induced surface morphology is studied. We demonstrated by Raman spectroscopy that our MAPLE-deposited cinnamate-pullulan thin films are composed of starting materials preserving their chemical structures, with no impurities.

  3. Combinatorial screening of halide perovskite thin films and solar cells by mask-defined IR laser molecular beam epitaxy

    OpenAIRE

    Kawashima, Kazuhiro; Okamoto, Yuji; Annayev, Orazmuhammet; Toyokura, Nobuo; Takahashi, Ryota; Lippmaa, Mikk; Itaka, Kenji; Suzuki, Yoshikazu; Matsuki, Nobuyuki; Koinuma, Hideomi

    2017-01-01

    Abstract As an extension of combinatorial molecular layer epitaxy via ablation of perovskite oxides by a pulsed excimer laser, we have developed a laser molecular beam epitaxy (MBE) system for parallel integration of nano-scaled thin films of organic?inorganic hybrid materials. A pulsed infrared (IR) semiconductor laser was adopted for thermal evaporation of organic halide (A-site: CH3NH3I) and inorganic halide (B-site: PbI2) powder targets to deposit repeated A/B bilayer films where the thic...

  4. Intraoperative arrhythmias and tissue damage during transmyocardial laser revascularization.

    Science.gov (United States)

    Kadipaşaoglu, K A; Sartori, M; Masai, T; Cihan, H B; Clubb, F J; Conger, J L; Frazier, O H

    1999-02-01

    Transmyocardial laser revascularization creates transmural channels to improve myocardial perfusion. Different laser sources and ablation modalities have been proposed for transmyocardial laser revascularization. We investigated the incidence of cardiac arrhythmias and laser-tissue interactions during transmyocardial laser revascularization of normal porcine myocardium with three different lasers. We used a continuous-wave, chopped CO2 laser (20 J/pulse, 15 ms/pulse) synchronized with the R wave; a holmium:yttrium aluminum garnet (Ho:YAG) laser (2 J/pulse, 250 micros/pulse, 5 Hz); and a xenon-chloride (excimer, Xe:Cl) laser (35 mJ/pulse, 20 ns/pulse, 30 Hz). Each laser was used 30 times as the sole modality in four consecutive pigs, yielding 120 channels. The average number of pulses needed to create a channel was 1, 11 +/- 4, and 37 +/- 8 for the CO2, Ho:YAG, and Xe:Cl lasers, respectively. All Ho:YAG and Xe:Cl channels had premature ventricular contractions. Ventricular tachycardia occurred in 70% of the Xe:Cl and 60% of the Ho:YAG channels. Only 36% of the CO2 channels had premature ventricular contractions, and only 3% of the CO2 channels had ventricular tachycardia (p CO2 channels were straight and well demarcated. The zone of structural and thermal damage extended over half the channel's diameter, measuring 0.52 +/- 0.25 mm. During transmyocardial laser revascularization, the CO2 laser synchronized with the R wave is significantly less arrhythmogenic than the Ho:YAG and Xe:Cl lasers not synchronized with the R wave. In addition, the interaction of the CO2 laser with porcine cardiac tissue is significantly less traumatic than that of the Ho:YAG and the Xe:Cl lasers.

  5. Nuclear-driven flashlamp pumping of the atomic iodine laser

    Energy Technology Data Exchange (ETDEWEB)

    Miley, G.H.

    1992-03-01

    This report is a study of the atomic iodine laser pumped with nuclear- excited XeBr fluorescence. Preliminary experiments, conducted in the TRIGA reactor investigated the fluorescence of the excimer XeBr under nuclear pumping with {sup 10}B and {sup 3}He, for use as a flashlamp gas to stimulate the laser. These measurements included a determination of the fluorescence efficiency (light emitted in the wavelength region of interest, divided by energy deposited in the gas) of XeBr under nuclear pumping, with varying excimer mixtures. Maximum fluorescence efficiencies were approximately 1%. In order to better understand XeBr under nuclear excitation, a kinetics model of the system was prepared. The model generated the time-dependant concentrations of 20 reaction species for three pulse sizes, a TRIGA pulse, a fast burst reactor pulse, and an e-beam pulse. The modeling results predicted fluorescence efficiencies significantly higher (peak efficiencies of approximately 10%) than recorded in the fluorescence experiments. The cause of this discrepancy was not fully determined. A ray tracing computer model was also prepared to evaluate the efficiency with which nuclear-induced fluorescence generated in one cavity of a laser could be coupled into another cavity containing an iodine lasant. Finally, an experimental laser cell was constructed to verify that nuclear-induced XeBr fluorescence could be used to stimulate a laser. Lasing was achieved at 1.31 micron in the TRIGA using C{sub 3}F{sub 7}I, a common iodine lasant. Peak laser powers were approximately 20 mW. Measured flashlamp pump powers at threshold agreed well with literature values, as did lasant pressure dependency on laser operation.

  6. UV Raman spectroscopy of H2-air flames excited with a narrowband KrF laser

    Science.gov (United States)

    Shirley, John A.

    1990-01-01

    Raman spectra of H2 and H2O in flames excited by a narrowband KrF excimer laser are reported. Observations are made over a porous-plug, flat-flame burner reacting H2 in air, fuel-rich with nitrogen dilution to control the temperature, and with an H2 diffusion flame. Measurements made from UV Raman spectra show good agreement with measurements made by other means, both for gas temperature and relative major species concentrations. Laser-induced fluorescence interferences arising from OH and O2 are observed in emission near the Raman spectra. These interferences do not preclude Raman measurements, however.

  7. Photochemically induced deposition of protective alumina coatings onto UV emitting phosphors for Xe excimer discharge lamps

    Energy Technology Data Exchange (ETDEWEB)

    Broxtermann, Mike, E-mail: mike.b@fh-muenster.de; Jüstel, Thomas, E-mail: tj@fh-muenster.de

    2016-08-15

    Highlights: • A UV-reactor for the pH induced precipitation of inorganic material is described. • The photolysis of Azide (N{sub 3}{sup −}) leads to a steady pH increase used for precipitation. • A UV induced Al(OH){sub 3} precipitation is used to craft Al{sub 2}O{sub 3} coatings onto YPO{sub 4}:Bi. • The influence of Al{sub 2}O{sub 3} coated onto YPO{sub 4}:Bi with different thicknesses is discussed. • SEM, VUV-spectroscopy and ESA measurements were performed on Al{sub 2}O{sub 3} coated samples. - Abstract: This work concerns the particle coating of the UV-C emitting phosphor YPO{sub 4}:Bi, targeting a stability enhancement of the phosphor material for Xe excimer lamp operation. To this end, the material is coated by the wide band gap material Al{sub 2}O{sub 3}. In order to obtain a thin and homogeneous coating layer, a novel process based on the photochemical cleavage of NaN{sub 3} in water was developed. This results in a slow and continuous enhancement of the pH value due to ongoing NaOH formation, which results in the precipitation of Al(OH){sub 3} from an Al{sub 2}(SO{sub 4}){sub 3} {sub ×} 18H{sub 2}O solution. It turned out that the obtained particle coatings are of much better quality, i.e. homogeneity, compared to coatings made from a wet-chemical homogeneous precipitation process. The morphology and electrochemical properties of Al{sub 2}O{sub 3} coated YPO{sub 4}:Bi are discussed on the basis of optical spectroscopy, ESA measurements, and SEM/EDX investigations.

  8. Deposition of tantalum carbide coatings on graphite by laser interactions

    Science.gov (United States)

    Veligdan, James; Branch, D.; Vanier, P. E.; Barietta, R. E.

    1994-01-01

    Graphite surfaces can be hardened and protected from erosion by hydrogen at high temperatures by refractory metal carbide coatings, which are usually prepared by chemical vapor deposition (CVD) or chemical vapor reaction (CVR) methods. These techniques rely on heating the substrate to a temperature where a volatile metal halide decomposes and reacts with either a hydrocarbon gas or with carbon from the substrate. For CVR techniques, deposition temperatures must be in excess of 2000 C in order to achieve favorable deposition kinetics. In an effort to lower the bulk substrate deposition temperature, the use of laser interactions with both the substrate and the metal halide deposition gas has been employed. Initial testing involved the use of a CO2 laser to heat the surface of a graphite substrate and a KrF excimer laser to accomplish a photodecomposition of TaCl5 gas near the substrate. The results of preliminary experiments using these techniques are described.

  9. The Antifibrosis Effects of Peroxisome Proliferator-Activated Receptor δ on Rat Corneal Wound Healing after Excimer Laser Keratectomy

    Directory of Open Access Journals (Sweden)

    Yun Gu

    2014-01-01

    Full Text Available Corneal stromal fibrosis characterized by myofibroblasts and abnormal extracellular matrix (ECM is usually the result of inappropriate wound healing. The present study tested the hypothesis that the ligand activation of peroxisome proliferator-activated receptor (PPAR δ had antifibrosis effects in a rat model of corneal damage. Adult Sprague-Dawley rats underwent bilateral phototherapeutic keratectomy (PTK. The eyes were randomized into four groups: PBS, GW501516 (a selective agonist of PPARδ, GSK3787 (a selective antagonist of PPARδ, or GW501516 combined with GSK3787. The agents were subconjunctivally administered twice a week until sacrifice. The cellular aspects of corneal wound healing were evaluated with in vivo confocal imaging and postmortem histology. A myofibroblast marker (α-smooth muscle actin and ECM production (fibronectin, collagen type III and collagen type I were examined by immunohistochemistry and RT-PCR. At the early stages of wound healing, GW501516 inhibited reepithelialization and promoted angiogenesis. During the remodeling phase of wound healing, GW501516 attenuated the activation and proliferation of keratocytes, which could be reversed by GSK3787. GW501516 decreased transdifferentiation from keratocytes into myofibroblasts, ECM synthesis, and corneal haze. These results demonstrate that GW501516 controls corneal fibrosis and suggest that PPARδ may potentially serve as a therapeutic target for treating corneal scars.

  10. [Effects of amniotic extraction on epithelial wound healing and stromal remodelling after excimer laser keratectomy in rabbit cornea].

    Science.gov (United States)

    Xiao, Qiguo; Chen, Yuan; Du, Juan; Wang, Hua; Li, Wei; Liu, Zuguo

    2014-01-01

    To investigate the effects and mechanism of amniotic extraction on corneal healing after photorefractive keratectomy (PRK). Experimental Study. Thirty-six New Zealand rabbit corneas were performed with PRK models (-10 diopters, 6.5 mm diameter). According to random number table, all eyes were divided into three groups, including treated with amniotic extraction, 0.1% dexamethasone and excipient respectively after operation. Clinical and histopathologic examinations were taken by slit-lamp microscope and light microscope. Corneal epithelium reparation was observed by fluorescent staining. Corneal stroma cell apoptosis was evaluated by terminal deoxyribonucleotidyl transferase-mediated deoxyuridine triphosphate nick end labeling (TUNEL) assay. Myofibroblast generation was evaluated by immunofluorescence checking the expression of alpha-smooth muscle actin (α-SMA). The number of TUNEL and α-SMA positive cells was analyzed to explore the effects on corneal haze. The haze grading was compared between groups using Kruskal-Wallis H test. Mean values for each experiment were compared between groups using a one-way analysis of variance and LSD-t test.Spearman rank analysis was used to evaluate the correlation between the haze grading and the expression of TUNEL positive cells and α-SMA. The corneas of seventy-two eyes reepithelialized in 6 days after operation. The average epithelium repair time of the AE group was (4.12 ± 0.62) d, the dexamethasone group was (5.25 ± 0.78) d, and the excipient group was (4.96 ± 0.73) d. The progression of reepithelialization was significantly faster in the AE group than the other two groups (F = 14.144, P healing of epithelial cell by interacting with the corneal cell factors, reducing the cell apoptosis, corneal wound healing response and rebuilding the corneal matrix with less myofibroblast, collagen and scar and finally reduce the formation of haze.

  11. UV and RIR matrix assisted pulsed laser deposition of organic MEH-PPV films

    DEFF Research Database (Denmark)

    Christensen, Bo Toftmann; Papantonalis, M.R.; Auyeung, R.C.Y.

    2004-01-01

    A comparative study of thin film production based on gentle laser-ablation techniques has been carried out with the luminescent polymer poly [2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenylene vinylene]. Using a free-electron laser films were made by resonant infrared pulsed laser deposition (RIR......-PLD). For the first time resonant infrared matrix assisted pulsed laser evaporation (RIR-MAPLE) was successfully demonstrated on a luminescent polymer system. In addition to this, an excimer laser has been used for UV-MAPLE depositions at 193 and 248-nm irradiation. Films deposited onto NaCl and quartz substrates...... were analyzed by Fourier transform infrared spectroscopy, UV-visible absorbance and photoluminescence. Photoluminescent material was deposited by RIR-MAPLE and 248-nm MAPLE, while the RIR-PLD and 193-nm-MAPLE depositions displayed the smoothest surfaces but did not show photoluminescence. (C) 2003...

  12. Keratin film ablation for the fabrication of brick and mortar skin structure using femtosecond laser pulses

    Science.gov (United States)

    Haq, Bibi Safia; Khan, Hidayat Ullah; Dou, Yuehua; Alam, Khan; Attaullah, Shehnaz; Zari, Islam

    2015-09-01

    The patterning of thin keratin films has been explored to manufacture model skin surfaces based on the "bricks and mortar" view of the relationship between keratin and lipids. It has been demonstrated that laser light is capable of preparing keratin-based "bricks and mortar" wall structure as in epidermis, the outermost layer of the human skin. "Bricks and mortar" pattern in keratin films has been fabricated using an ArF excimer laser (193 nm wavelength) and femtosecond laser (800 and 400 nm wavelength). Due to the very low ablation threshold of keratin, femtosecond laser systems are practical for laser processing of proteins. These model skin structures are fabricated for the first time that will help to produce potentially effective moisturizing products for the protection of skin from dryness, diseases and wrinkles.

  13. Evaluation of the use of four different lasers in oral soft tissue surgery

    Science.gov (United States)

    Gaspar, Lajos

    1995-04-01

    There have been 4032 laser surgical operations for the last 7 years with first generation lasers available CO2, Nd:YAG, Argon, Combo (CO2 + $Nd:YAG). The most important experience, the advantages and disadvantages of application are shown by the evaluation of the results and complications. In oral soft tissue surgery there have been established the most important indicational circles of the use of first generation lasers. The clinical introduction of a second generation of surgical lasers Ho:YAG, ER:YAG, Excimer etc. brings new possibilities in not only hard tissue surgery, but it also widens the advantages of the use of surgical lasers in the surgery of oral soft tissues.

  14. Use of different surgical lasers in oral soft-tissue surgery and dentistry

    Science.gov (United States)

    Gaspar, Lajos

    1994-12-01

    There have been 4,032 laser surgical operations for the last 7 years with available first generation lasers (CO2, Nd:YAG, argon, combo (CO2 + Nd:YAG). The most important experience, the advantages and disadvantages of application are shown by the evaluation of results and complications. In oral soft tissue surgery the most important indicational circles of the use of first generation lasers have been established. The clinical introduction of a second generation of surgical lasers (Ho:YAG, Er:YAG, excimer, etc.) brings new possibilities in not only hard tissue surgery, but it also widens the advantages of the use of surgical lasers in the surgery of oral soft tissues.

  15. Functionalised polyurethane for efficient laser micromachining

    Science.gov (United States)

    Brodie, G. W. J.; Kang, H.; MacMillan, F. J.; Jin, J.; Simpson, M. C.

    2017-02-01

    Pulsed laser ablation is a valuable tool that offers a much cleaner and more flexible etching process than conventional lithographic techniques. Although much research has been undertaken on commercially available polymers, many challenges still remain, including contamination by debris on the surface, a rough etched appearance and high ablation thresholds. Functionalizing polymers with a photosensitive group is a novel way and effective way to improve the efficiency of laser micromachining. In this study, several polyurethane films grafted with different concentrations of the chromophore anthracene have been synthesized which are specifically designed for 248 nm KrF excimer laser ablation. A series of lines etched with a changing number of pulses and fluences by the nanosecond laser were applied to each polyurethane film. The resultant ablation behaviours were studied through optical interference tomography and Scanning Electron Microscopy. The anthracene grafted polyurethanes showed a vast improvement in both edge quality and the presence of debris compared with the unmodified polyurethane. Under the same laser fluence and number of pulses the spots etched in the anthracene contained polyurethane show sharp depth profiles and smooth surfaces, whereas the spots etched in polyurethane without anthracene group grafted present rough cavities with debris according to the SEM images. The addition of a small amount of anthracene (1.47%) shows a reduction in ablation threshold from unmodified polyurethane showing that the desired effect can be achieved with very little modification to the polymer.

  16. Heat generation in laser irradiated tissue.

    Science.gov (United States)

    Welch, A J; Pearce, J A; Diller, K R; Yoon, G; Cheong, W F

    1989-02-01

    Many medical applications involving lasers rely upon the generation of heat within the tissue for the desired therapeutic effect. Determination of the absorbed light energy in tissue is difficult in many cases. Although UV wavelengths of the excimer laser and 10.6 microns wavelength of the CO2 laser are absorbed within the first 20 microns of soft tissue, visible and near infrared wavelengths are scattered as well as absorbed. Typically, multiple scattering is a significant factor in the distribution of light in tissue and the resulting heat source term. An improved model is presented for estimating heat generation due to the absorption of a collimated (axisymmetric) laser beam and scattered light at each point r and z in tissue. Heat generated within tissue is a function of the laser power, the shape and size of the incident beam and the optical properties of the tissue at the irradiation wavelength. Key to the calculation of heat source strength is accurate estimation of the light distribution. Methods for experimentally determining the optical parameters of tissue are discussed in the context of the improved model.

  17. Pilot study of laser induced breakdown spectroscopy for tissue differentiation by monitoring the plume created during laser surgery — An approach on a feedback Laser control mechanism

    Science.gov (United States)

    Kanawade, Rajesh; Mehari, Fanuel; Knipfer, Christian; Rohde, Maximilian; Tangermann-Gerk, Katja; Schmidt, Michael; Stelzle, Florian

    2013-09-01

    This study focuses on tissue differentiation using 'Laser Induced Breakdown Spectroscopy' (LIBS) by monitoring the plasma plume created during laser surgery processes. This technique is aimed at controlling a laser surgery feedback system in real time. An Excimer laser (Ar-F 193 nm) was used for the ablation of tissue samples. Fat, muscle, nerve and skin tissue samples of bisected ex-vivo pig heads were prepared as test objects for the ablation procedure. A single fiber was used to collect emissions and deliver them to a spectrometer. The obtained LIBS spectra in the measured emissions were analyzed to determine each tissue type according to their chemical composition. The elements found in the samples and their emission spectra were in agreement with those described in literature. The collected LIBS spectra were analyzed to differentiate the tissues using statistical data analysis: Principal Component Analysis (PCA), Linear Discriminant Analysis (LDA) and Receiver Operating Characteristics (ROC). The obtained preliminary results suggest a successful differentiation of the target tissues with high sensitivity and specificity. The main goal of this study was to qualitatively identify tissue types during laser ablation, which will provide a real time feedback mechanism for clinical Laser surgery applications to significantly improve the accuracy and safety of laser surgery procedures.

  18. Optical performance of thin films produced by the pulsed laser deposition of SiAlON and Er targets

    Science.gov (United States)

    Camps, I.; Ramírez, J. M.; Mariscal, A.; Serna, R.; Garrido, B.; Perálvarez, M.; Carreras, J.; Barradas, N. P.; Alves, L. C.; Alves, E.

    2015-05-01

    We report the preparation and optical performance of thin films produced by pulsed laser deposition in vacuum at room temperature, by focusing an ArF excimer laser onto two separate targets: a commercial ceramic SiAlON and a metallic Er target. As a result of the alternate deposition Er:SiAlON films were formed. The as grown films exhibited an Er-related emission peaking at 1532 nm. The role of the PLD energy density during deposition on the final matrix film was investigated, in order to achieve an optimized matrix composition with enhanced optical properties, and its effect on the light emission performance.

  19. Morphological studies of laser-induced photoacoustic damage

    Science.gov (United States)

    Flotte, Thomas J.; Yashima, Yutaka; Watanabe, Shinichi; McAuliffe, Daniel J., Sr.; Jacques, Steven L.

    1990-06-01

    Argon-fluoride excimer laser ablation of stratum comeum causes deeper tissue damage than expected for thermal or photochemical mechanisms, suggesting thatphotoacoustic waves have arole in tissue damage. Laserirradiation (193 nm, 14 ns pulses, 1-2 Hz) attworadiantexposures, 60 and 160 mJ/cm2perpulse was usedto ablate the stratumcomeumofskin. Light and electron microscopy ofimmediate biopsies demonstrated damage to fibroblasts as deep as 88 and 220 jun, respectively, below the ablation site. Ablation throughwaterwas usedtoinertially confine the ablation zone. Partial ablationofs.c. through airproducedno damage, whereas partial ablation through water damaged skin to amean depth of 1 14.5 8.8( Full thickness ablation of s.c. through air and water produced damage zones measuring 192.2 16.2 and 293.0 71.6 rim, respectively (p mechanism ofdamage. The depths ofdamage for thelarge spot, line, and small spots were 43 1 164 urn, 269 96xni, andno damage. The spot size dependence ofthedepthofdamage is consistentwiththe geometric attenuation one would expect to be present from a pressure wave related phenomena. Sequential biopsies were taken over a 7 day period for light and transmission electron microscopy. At 24 hours, there was necrosis of the epidermis and papillary dermis subjacent to the ablation site, with neutrophils surrounding and demarcating the affected area. The necrotic zone sloughedby48 hours. Thereepithelializationwas completeby7 days. The sequenceofrepairis similartoknife wound healing which we have previously studied, and is analogous to other wound healing processes. We have used an experimental model of ArF excimer laser ablation of stratum corneum to investigate laser-induced photoacoustic damage. The evidence for the injury being due to pressure transients is indirectbutcompelling. Whether these pressuretransients are acoustic transients orshockwaves has notbeendetermined, although itis ourprejudicethatshockwaves are the predominant force under these

  20. Application of ultrashort laser pulses for intrastromal refractive surgery.

    Science.gov (United States)

    Lubatschowski, H; Maatz, G; Heisterkamp, A; Hetzel, U; Drommer, W; Welling, H; Ertmer, W

    2000-01-01

    Recently, laser systems have become available which generate ultrashort laser pulses with a duration of 100-200 femtoseconds (fs). By generating micro-plasmas inside the corneal stroma with fs pulses, it is possible to achieve a cutting effect inside the tissue while leaving the anterior layers intact. The energy threshold to generate a micro-plasma with fs pulses is some orders of magnitude lower than it is for picosecond or nanosecond pulses. This results in a strong reduction of the thermal and mechanical damage of the surrounding tissue. With a titanium:sapphire fs laser system, the cutting effect on corneal tissue from freshly enucleated porcine eye globes was investigated with different pulse energies. The irradiated samples were examined by light and electron microscopy. The laser-induced pressure transients and the laser-induced bubble formation were analysed with a broadband acoustic transducer and by flash photography. With fs laser pulses, the extent of thermal and mechanical damage of the adjacent tissue is in the order of 1 microm or below and therefore comparable with the tissue alterations after ArF excimer laser ablation. Using pulse energies of approximately 1-2 microJ and a spot diameter of 5-10 microm, intrastromal cuts can be performed very precisely in order to prepare corneal flaps and lenticules. Femtosecond photodisruption has the potential to become an attractive tool for intrastromal refractive surgery.

  1. Laser in situ keratomileusis in myopic patients with congenital nystagmus.

    Science.gov (United States)

    Mahler, Ori; Hirsh, Ami; Kremer, Israel; Barequet, Irina S; Marcovich, Arie L; Nemet, Pinhas; Levinger, Samuel

    2006-03-01

    To evaluate the results of laser in situ keratomileusis (LASIK) and IntraLASIK in the treatment of myopic patients with nystagmus. Eight patients with congenital nystagmus (16 eyes), aged 23 to 49 years, had LASIK surgery. Corneal flaps were created using the Bausch & Lomb Hansatome microkeratome or the IntraLase femtosecond laser. The ablations were performed with the Bausch & Lomb excimer laser with an active tracking system. In some patients, the eyes were fixated with forceps or a fixation ring during laser ablation. The refractive errors were corrected in all cases. There was no decentration or loss of best corrected visual acuity greater than 1 line. In 56% of the eyes, the postoperative uncorrected visual acuity was better than the best spectacle-corrected visual acuity (BSCVA). The BSCVA improved in 62.5% of the eyes. The overall visual performance improved in all patients. One patient who did not drive before surgery became eligible for a driver's license after surgery. Selected patients with myopia and congenital nystagmus may benefit from laser refractive surgery. Laser refractive surgery may be safely and accurately performed using the Hansatome microkeratome or the IntraLase femtosecond laser and an active tracking system with or without mechanical fixation. The BSCVA may improve in certain patients postoperatively.

  2. Frequency doubling of copper lasers using temperature-tuned ADP

    Energy Technology Data Exchange (ETDEWEB)

    Molander, W.A.

    1994-03-01

    The ability to generate high average power uv at 255 nm by frequency doubling the green line (510.6 nm) of copper lasers would greatly extend the utility of copper lasers. Material processing and microlithography are two areas of interest. The frequency-doubled copper laser could replace the KrF excimer laser, which has a similar wavelength (248 nm), in some applications. The frequency-doubled copper laser has a narrow linewidth and excellent beam quality at a competitive cost. Other attractive features are high reliability, low operating costs, and the absence of toxic gases. This paper will report recent progress in high-efficiency, high-average-power harmonic generation of the copper laser green line using noncritical phase matching in ADP. Frequency doubling of the yellow line (578.2 nm) and sum-frequency mixing of the two lines are also of interest. These processes, however, cannot be phase-matched in ADP and, therefore, will not be discussed here. The results reported and the issues identified here would be important in these other processes and also in many other frequency conversion schemes in the uv such as 4{omega} conversion of Nd{sup 3+}:YAG lasers.

  3. Biomolecular urease thin films grown by laser techniques for blood diagnostic applications

    Energy Technology Data Exchange (ETDEWEB)

    Gyoergy, E., E-mail: eniko.gyorgy@inflpr.ro [Consejo Superior de Investigaciones Cientificas, Institut de Ciencia de Materials de Barcelona and Centre d' Investigacions en Nanociencia i Nanotecnologia, Campus UAB, 08193 Bellaterra (Spain); National Institute for Lasers, Plasma and Radiations Physics, P. O. Box MG 36, 77125 Bucharest (Romania); Sima, F.; Mihailescu, I.N. [National Institute for Lasers, Plasma and Radiations Physics, P. O. Box MG 36, 77125 Bucharest (Romania); Smausz, T. [Department of Optics and Quantum Electronics, University of Szeged, H-6720 Szeged, Dom ter 9 (Hungary); Hopp, B. [Hungarian Academy of Sciences and University of Szeged, Research Group on Laser Physics, H-6720 Szeged, Dom ter 9 (Hungary); Predoi, D. [National Institute for Physics of Materials, P.O. Box MG 07, Bucharest, Magurele (Romania); Sima, L.E.; Petrescu, S.M. [Institute of Biochemistry, Romanian Academy, Splaiul Independentei 296, 060031 Bucharest (Romania)

    2010-05-10

    Matrix assisted pulsed laser evaporation (MAPLE) was used for growing urease thin films designed for bio-sensor applications in clinical diagnostics. The targets exposed to laser radiation were made from a frozen composite manufactured by dissolving biomaterials in distilled water. We used a UV KrF* ({lambda} = 248 nm, {tau}{sub FWHM} {approx_equal} 30 ns, {nu} = 10 Hz) excimer source for multipulse laser irradiation of the frozen targets cooled with Peltier elements. The laser source was operated at an incident fluence of 0.4 J/cm{sup 2}. Urease activity and kinetics were assayed by the Worthington method that monitors urea hydrolysis by coupling ammonia production to a glutamate dehydrogenase reaction. A decrease in absorbance was measured at 340 nm and correlated with the enzymatic activity of urease. We show that the urease films obtained by MAPLE techniques remain active up to three months after deposition.

  4. Ultraviolet and laser irradiation effects on various batches of CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.; Islam, M.A.; Abu-Abdoun, I.; Khan, M.A. (King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia))

    1991-01-01

    Different batches of the plastic track detector CR-39 were irradiated with various ultraviolet (UV) sources and an excimer laser ({lambda} = 308). A visible change of color of detectors under heavy doses appeared in both cases. The exposure to ordinary (non-linear) UV light sources resulted in an increase of the track sizes, bulk and track etch rate at two different wavelengths 254 nm and 350 nm. At 300 nm no increase was observed. On the other hand, the exposure to the laser resulted in hardening of the surfaces and therefore a decreasing of track sizes. The laser effect (hardening) was, however, found to saturate above a certain exposure dose. The observed hardening of laser irradiated detectors suggests their possible use in the detection and study of ultra energetic particles without unnecessarily increasing the thickness of the detectors. (author).

  5. Pulse duration and wavelength effects in laser scribing of thin-film polycrystalline PV materials

    Science.gov (United States)

    Compaan, A. D.; Matulionis, I.; Nakade, S.; Jayamaha, U.

    1997-02-01

    This project is focussed on a study of wavelength-dependent effects and pulse-duration effects on laser scribing of polycrystalline thin-film PV materials. The materials studied here are CdTe, CI(G)S, SnO2, ZnO, molybdenum and gold. This paper provides a summary of thresholds and optimum scribing energy densities for two types of Nd:YAG lasers, a 308 nm excimer laser, and a copper vapor laser. A comparison is presented of glass-side vs. film-side scribing. Discussion is also given of scribing of multilayer films such as ZnO/CIS/moly and gold/CdTe/SnO2.

  6. Pilot study of laser induced breakdown spectroscopy for tissue differentiation by monitoring the plume created during laser surgery — An approach on a feedback Laser control mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kanawade, Rajesh, E-mail: Rajesh.Kanawade@aot.uni-erlangen.de [Clinical Photonics Lab, Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Paul-Gordan-Str. 6, 91052 Erlangen (Germany); Institute of Photonics Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Paul-Gordan-Str. 3, 91052 Erlangen (Germany); Mehari, Fanuel [Master Programme in Advanced Optical Technologies (MAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Paul-Gordan-Str. 6, 91052 Erlangen (Germany); Knipfer, Christian; Rohde, Maximilian [Department of Oral and Maxillofacial Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Glueckstrasse 11, 91054 Erlangen (Germany); Tangermann-Gerk, Katja [Bayerisches Laserzentrum GmbH, Konrad-Zuse-Strasse 2-6, 91052 Erlangen (Germany); Schmidt, Michael [Clinical Photonics Lab, Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Paul-Gordan-Str. 6, 91052 Erlangen (Germany); Institute of Photonics Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, Paul-Gordan-Str. 3, 91052 Erlangen (Germany); Bayerisches Laserzentrum GmbH, Konrad-Zuse-Strasse 2-6, 91052 Erlangen (Germany); and others

    2013-09-01

    This study focuses on tissue differentiation using ‘Laser Induced Breakdown Spectroscopy’ (LIBS) by monitoring the plasma plume created during laser surgery processes. This technique is aimed at controlling a laser surgery feedback system in real time. An Excimer laser (Ar-F 193 nm) was used for the ablation of tissue samples. Fat, muscle, nerve and skin tissue samples of bisected ex-vivo pig heads were prepared as test objects for the ablation procedure. A single fiber was used to collect emissions and deliver them to a spectrometer. The obtained LIBS spectra in the measured emissions were analyzed to determine each tissue type according to their chemical composition. The elements found in the samples and their emission spectra were in agreement with those described in literature. The collected LIBS spectra were analyzed to differentiate the tissues using statistical data analysis: Principal Component Analysis (PCA), Linear Discriminant Analysis (LDA) and Receiver Operating Characteristics (ROC). The obtained preliminary results suggest a successful differentiation of the target tissues with high sensitivity and specificity. The main goal of this study was to qualitatively identify tissue types during laser ablation, which will provide a real time feedback mechanism for clinical Laser surgery applications to significantly improve the accuracy and safety of laser surgery procedures. - Graphical abstract: Skin, fat, muscle and nerve tissue differentiation. - Highlights: • Methods to differentiate tissues for the application in a laser surgery feedback control system • Successful differentiation of the target tissues with high sensitivity and specificity for laser surgery application • Real time feedback mechanism for clinical Laser surgery applications • Laser surgery requirements • Biomedical applications of LIBS.

  7. Fiscal 1998 research report on the metal thin film formation by UV laser photodecomposition of adsorbed organic metal compounds; Kyuchaku yuki kinzoku kagobutsu no shigai laser ko bunkai ni yoru usumaku sakuseiho ni kansuru kenkyu 1998 nendo chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Research was made on the new thin film formation method depositing metal or metal compound thin films by excimer laser photodecomposition of organic metal compounds condensed onto substrates at lower temperature. The organic metal compound was condensed onto cooled substrates (glass, semiconductor Si) from gas-phase iron pentacarbonyl below 250K in vacuum. KrF excimer laser was used as UV laser. The thin films with electric conductivity and metallic luster were deposited onto the laser irradiation areas of both substrates below 250K. The thin films were deposited only by proper laser pulse irradiation fluence (energy/unit area), and are composed of iron or its oxide. The deposition rate is estimated to be nearly 0.5nm/s, and precise control of film thicknesses is possible. Formation of pure metal and metal oxide thin films with various film thicknesses and compositions is probably possible by controlling thin film formation conditions. The iron thin film with characteristics of magnetic thin films is applicable to various fields, and is also important as the base for forming alloy films and multi-layered films. (NEDO)

  8. Bioactive glass thin films synthesized by advanced pulsed laser techniques

    Science.gov (United States)

    Mihailescu, N.; Stan, George E.; Ristoscu, C.; Sopronyi, M.; Mihailescu, Ion N.

    2016-10-01

    Bioactive materials play an increasingly important role in the biomaterials industry, and are extensively used in a range of applications, including biodegradable metallic implants. We report on Bioactive Glasses (BG) films deposition by pulsed laser techniques onto biodegradable substrates. The BG coatings were obtained using a KrF* excimer laser source (λ= 248 nm, τFWHM ≤ 25 ns).Their thickness has been determined by Profilometry measurements, whilst their morphology has been analysed by Scanning Electron Microscopy (SEM). The obtained coatings fairly preserved the targets composition and structure, as revealed by Energy Dispersive X-Ray Spectroscopy, Grazing Incidence X-Ray Diffraction, and Fourier Transform Infra-Red Spectroscopy analyses.

  9. Intrastromal refractive sugery with ultrashort laser pulses in living animals

    Science.gov (United States)

    Heisterkamp, Alexander; Mamom, Thanongsak; Kermani, Omid; Drommer, Wolfgang; Welling, Herbert; Ertmer, Wolfgang; Lubatschowski, Holger

    2002-06-01

    In order to perform refractive surgery, fs-laser pulses of 130-fs pulse duration were focused into animal cornea. By focusing the radiation down to spot-sizes of 5 micrometers , very precise cuts could be achieved inside the treated eyes, accompanied with minimum collateral damage to the tissue by thermal or mechanical effects. Due to these low side effects, micrometers -cutting precisions at preparing of corneal flaps and lenticules can be achieved. Thus, animal studies with 8 living rabbits were performed, in which intrastromal lenticules and flaps were created and extracted. Wound healing reactions were studied by histo- pathological analysis of the treated eyes in intervals at one, 7, 14 and 28 days after surgery. The treated eyes showed mild wound healing reactions with comparable results to what is known from Excimer-LASIK. Moreover the use of the fs-laser offered new possibilities in preparation of corneal flaps, providing advantages to the use of the mechanical keratome.

  10. Distinguished Lectureship Award on the Applications of Physics: Illuminating My Career - From Flash Gordon to Laser Surgery

    Science.gov (United States)

    Wynne, James

    2015-03-01

    As a child, I was fascinated by television programs about Flash Gordon. His partner in conquering the universe was Dr. Alexis Zarkov, a physicist, who had invented, among other things, a death ray gun. My personal ``death ray'' was a magnifying glass, focusing sunlight on unsuspecting insects, like crawling ants. I also practiced sneaking up on resting, flying, stinging insects and burning their wings before they could take off and attack me. So I understood something about the power of sunlight. In my senior year of high school, I had a fabulous physics teacher, Lewis E. Love, and I knew after one week that I wanted to be a physicist, not a medical doctor, which is the career my parents wanted me to pursue. It turns out that the first laser functioned on May 16, 1960, just one month before I graduated from high school, and it was inevitable that I would pursue a career working with lasers. My first job as a physicist, during the summer of 1963, was working with lasers at TRG, Inc. a small company whose guru was Gordon Gould, now recognized as the inventor of the laser. After three summers at TRG, I spent three years working on nonlinear optics for my PhD thesis, under the guidance of Prof. Nicolaas Bloembergen, who later won the Nobel Prize in Physics for codifying nonlinear optics. Following completion of my PhD research in 1969, I joined IBM Research, where I have worked ever since. Upon joining the Quantum Electronics group in the Physical Sciences Dept. of the T.J. Watson Research Center, my management told me to ``do something great'' with lasers. After working on atomic spectroscopy with dye lasers through the 1970s, I had the inspiration to acquire an excimer laser for the Laser Physics and Chemistry group. Using this laser, my colleagues and I discovered excimer laser surgery, capable of removing human and animal tissue with great precision, while leaving the underlying and adjacent tissue free of collateral damage. This discovery laid the foundation for

  11. Synthesis and characterization of CdSe/ZnS core-shell quantum dots immobilized on solid substrates through laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gyoergy, E. [Centre d' Investigacions en Nanociencia i Nanotecnologia, Institut Catala de Nanotecnologia, Consejo Superior de Investigaciones Cientificas (CIN2, ICN-CSIC), Bellaterra (Spain); National Institute for Lasers, Plasma and Radiation Physics, Bucharest (Romania); Perez del Pino, A. [Instituto de Ciencia de Materiales de Barcelona, Consejo Superior de Investigaciones Cientificas (ICMAB, CSIC), Bellaterra (Spain); Roqueta, J.; Ballesteros, B. [Centre d' Investigacions en Nanociencia i Nanotecnologia, Institut Catala de Nanotecnologia, Consejo Superior de Investigaciones Cientificas (CIN2, ICN-CSIC), Bellaterra (Spain); Miguel, A.S.; Maycock, C.; Oliva, A.G. [Instituto de Tecnologia Quimica e Biologica, Universidade Nova de Lisboa (ITQB-UNL), Oeiras (Portugal)

    2012-11-15

    CdSe/ZnS core-shell quantum dots (QDs) have been immobilized onto solid substrates by matrix assisted pulsed laser evaporation (MAPLE). An UV KrF* ({lambda} = 248 nm, {tau}{sub FWHM} {approx_equal} 25 ns) excimer laser source was used for irradiations of the composite MAPLE targets. The targets were prepared by the dispersion of the CdSe/ZnS QDs in a solvent with high absorption at the incident laser radiation. The dependence of the surface morphology, crystalline structure, chemical composition, and functional properties of the laser transferred CdSe/ZnS QDs on the processing conditions as incident laser fluence value and ambient atmosphere inside the irradiation chamber was investigated. The possible physical mechanisms implied in the laser ablation process were identified. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Hyperopic laser in situ keratomileusis: comparison of femtosecond laser and mechanical microkeratome flap creation.

    Science.gov (United States)

    Antonios, Rafic; Arba Mosquera, Samuel; Awwad, Shady T

    2015-08-01

    To evaluate and compare the refractive predictability and stability of laser in situ keratomileusis (LASIK) flap creation performed with a femtosecond laser and with a mechanical microkeratome to correct mild to moderate hyperopia. American University of Beirut Medical Center, Beirut, Lebanon. Retrospective case series. Patients who had hyperopic LASIK treatment using the Amaris excimer laser were included. Eyes in which the LDV femtosecond laser was used for flap creation were compared with eyes in which the Moria M2 microkeratome was used. The microkeratome group comprised 53 eyes and the femtosecond laser group, 72 eyes. Baseline characteristics were similar between groups (P > .05). The mean spherical equivalent (SE) deviation from target 1 week postoperatively was -0.08 diopter (D) ± 0.58 (SD) in the femtosecond laser group and -0.06 ± 0.87 D in the microkeratome group (P = .92). Thereafter, the mean SE deviation from target increased gradually and by 6 months postoperatively was +0.30 ± 0.50 D and +0.70 ± 0.71 D, respectively (P = .001). The correlation between the achieved and the attempted SE refraction was better in the femtosecond laser group (R(2) = 0.806) than the microkeratome group (R(2) = 0.671). Using the same nomogram, the short-term refractive outcomes of hyperopic LASIK with flap creation performed with the femtosecond laser were comparable to those for the microkeratome; however, the femtosecond group showed significantly better stability over the 6-month follow-up and better predictability, as reflected by a lower standard deviation and stronger Pearson correlation. Dr. Arba Mosquera is an employee of Schwind eye-tech-solutions GmbH and Co. KG. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Effects of laser irradiation on Trichophyton rubrum growth and ultrastructure.

    Science.gov (United States)

    Xu, Zhi-Li; Xu, Jing; Zhuo, Feng-Lin; Wang, Li; Xu, Wei; Xu, Ying; Zhang, Xiao-Yan; Zhao, Jun-Ying

    2012-10-01

    Trichophyton rubrum (T. rubrum) is the most common causative agent of dermatophytosis worldwide. In this study, we examined the effect of laser irradiation on the growth and morphology of T. rubrum. Colonies of T. rubrum were isolated (one colony per plate), and randomly assigned to 5 treatment groups: Q-switched 694 nm ruby laser treatment, long-pulsed Nd:YAG 1064 nm laser treatment, intense pulsed light (IPL) treatment, 308 nm excimer laser treatment and the blank control group without treatment. Standardized photographs were obtained from grown-up fungal plates prior to treatment. Colonies were then exposed to various wavelengths and fluences of laser light. To compare the growth of colonies, they were re-photographed under identical conditions three and six days post-treatment. To investigate the morphology of T. rubrum, scanning electron microscope (SEM) and transmission electron microscope (TEM) images were obtained from specimens exposed to 24 hours of laser treatment. Growth of T. rubrum colonies was significantly inhibited following irradiation by 694 nm Q-switched and 1064 nm long-pulsed Nd:YAG lasers. Other treatments exerted little or no effect. Q-switched laser irradiation exerted a stronger growth inhibitory effect than long-pulsed Nd:YAG laser irradiation. Following treatment by the Q-switched ruby laser system, T. rubrum hyphae became shrunken and deflated, and SEM images revealed rough, fractured hyphal surfaces, punctured with small destructive holes. TEM images showed that the hyphae were degenerating, as evidenced by the irregular shape of hyphae, rough and loose cell wall, and obscure cytoplasmic texture. Initially high electron density structure was visible in the cell; later, low-density structure appeared as a result of cytoplasmic dissolution. In contrast, the blank control group showed no obvious changes in morphology. The Q-switched 694 nm ruby laser treatment significantly inhibits the growth and changes the morphology of T. rubrum.

  14. Clinical results of 123 femtosecond laser-assisted penetrating keratoplasties.

    Science.gov (United States)

    Birnbaum, Florian; Wiggermann, Antonia; Maier, Philip C; Böhringer, Daniel; Reinhard, Thomas

    2013-01-01

    Postoperative astigmatism following penetrating keratoplasty is a major problem after corneal transplantation. The main goal of new trephination techniques such as femtosecond laser or excimer-laser trephination is to improve refractive and visual outcomes. The femtosecond laser technique makes profiled corneal trephinations such as the top hat or mushroom profile possible. We present the postoperative outcome of femtosecond laser-assisted penetrating keratoplasties. We performed 123 femtosecond laser-assisted penetrating keratoplasties in 119 patients. The main outcome measures were intraoperative specifics, astigmatism, and irregularity in Orbscan corneal topography, as well as the occurrence of immune reactions and side-effects. All sutures have been removed in 49 of these 123 eyes. Their mean follow-up was 13.9 ± 4.5 months. Time to complete suture removal (n = 49) was 12.0 ± 3.7 months in the mushroom group and 9.8 ± 2.1 months in the top hat group. Mean astigmatism in Orbscan topography was 6.4 ± 3.0 diopters in the mushroom and 5.8 ± 4.6 diopters in the top hat group (all sutures out). Femtosecond laser-assisted penetrating keratoplasty is a safe surgical technique. Due to the steps in profiled trephinations, the wound area is larger and theoretically the wound healing is, thus, faster and more stable. Complete suture removal is possible at an earlier time point compared to conventional penetrating keratoplasty. However, refractive results are not superior to those following conventional trephination.

  15. Turnable blue-green LIDAR transmitter demonstration: Injection laser technology

    Science.gov (United States)

    Nighan, W. L.; Rubino, R. A.; Cantor, A. J.; Glenn, W. H.

    1990-08-01

    In collaboration with Rice University, a scaling demonstration was made of the tunable, blue-green XeF(C-A) excimer laser focusing on the general requirements of a sensor for optical discrimination applications. Under separate contract Rice developed a scaled, repetitively pulsed XeF(C-A) laser amplifier. While under the present contract UTRC developed a wavelength agile dye laser as a source of injection control for the Rice amplifier. In late 1989 the UTRC injection laser was successfully integrated with the Rice XeF(C-A) amplifier, resulting in wavelength agile XeF(C-A) laser operation at the 1 J/pulse level, combined with an intrinsic efficiency greater than 1 percent and a pulse repetition rate of 1 Hz. Random sequence wavelength agility on a pulse-to-pulse basis was demonstrated over a 20 nm band, and an over-all efficient tuning range approach 50 nm was demonstrated. The UTRC portion of the program, wavelength-agile injection laser technology is covered.

  16. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK.

    Science.gov (United States)

    Lee, Jimmy K; Chuck, Roy S; Park, Choul Yong

    2015-07-01

    Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.

  17. Nuclear-driven flashlamp pumping of the atomic iodine laser. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Miley, G.H.

    1992-03-01

    This report is a study of the atomic iodine laser pumped with nuclear- excited XeBr fluorescence. Preliminary experiments, conducted in the TRIGA reactor investigated the fluorescence of the excimer XeBr under nuclear pumping with {sup 10}B and {sup 3}He, for use as a flashlamp gas to stimulate the laser. These measurements included a determination of the fluorescence efficiency (light emitted in the wavelength region of interest, divided by energy deposited in the gas) of XeBr under nuclear pumping, with varying excimer mixtures. Maximum fluorescence efficiencies were approximately 1%. In order to better understand XeBr under nuclear excitation, a kinetics model of the system was prepared. The model generated the time-dependant concentrations of 20 reaction species for three pulse sizes, a TRIGA pulse, a fast burst reactor pulse, and an e-beam pulse. The modeling results predicted fluorescence efficiencies significantly higher (peak efficiencies of approximately 10%) than recorded in the fluorescence experiments. The cause of this discrepancy was not fully determined. A ray tracing computer model was also prepared to evaluate the efficiency with which nuclear-induced fluorescence generated in one cavity of a laser could be coupled into another cavity containing an iodine lasant. Finally, an experimental laser cell was constructed to verify that nuclear-induced XeBr fluorescence could be used to stimulate a laser. Lasing was achieved at 1.31 micron in the TRIGA using C{sub 3}F{sub 7}I, a common iodine lasant. Peak laser powers were approximately 20 mW. Measured flashlamp pump powers at threshold agreed well with literature values, as did lasant pressure dependency on laser operation.

  18. Lasers technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    The Lasers Technology Program of IPEN is committed to the development of new lasers based on the research of optical materials and new technologies, as well to laser applications in several areas: Nuclear, Medicine, Dentistry, Industry, Environment and Advanced Research. The Program is basically divided into two main areas: Material and Laser Development and Laser Applications.

  19. A method for the measurement of in line pistachio aflatoxin concentration based on the laser induced fluorescence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Paghaleh, Soodeh Jamali [Vali-e-Asr University of Rafsanjan, Rafsanjan (Iran, Islamic Republic of); Askari, Hassan Ranjbar; Marashi, Seyed Mohammad Bagher [Department of Physics, Faculty of Science, Vali-e-Asr University of Rafsanjan, Rafsanjan (Iran, Islamic Republic of); Rahimi, Mojtaba, E-mail: m_rahimi@vru.ac.ir [Department of Physics, Faculty of Science, Vali-e-Asr University of Rafsanjan, Rafsanjan (Iran, Islamic Republic of); Bahrampour, Ali Reza [Physics Department of Sharif University of Technology, Tehran (Iran, Islamic Republic of)

    2015-05-15

    Contamination of pistachio nuts with aflatoxin is one of the most significant issues related to pistachio health and expert. A fast pistachio aflatoxin concentration measurement method based on the laser induced fluorescence spectroscopy (LIFS) is proposed. The proposed method from theoretical and experimental points of view is analyzed. In our experiments XeCl Excimer laser is employed as an Ultra Violet (UV) source (λ=308 nm) and a UV–visible (UV–vis) spectrometer is used for fluorescent emission detection. Our setup is employed to measure the concentration of different type of Aflatoxins in pistachio nuts. Measurements results obtained by the LIFS method are compared with those are measured by the standard HPLC method. Aflatoxins concentrations are in good agreement with those are obtained by the HPLC method. The proposed laser induced fluorescence spectroscopy can be used as an in line aflatoxins concentrations measurement instrument for industrial applications. - Highlights: • XeCl Excimer laser is employed as an UV source for measurement of AFs in pistachio nuts. • Results are compared with those are measured by the standard HPLC method. • LIFS is an online AFs concentration measurement method for industrial applications.

  20. Laser processing of polyethylene glycol derivative and block copolymer thin films

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, R. [National Institute for Laser, Plasma and Radiation Physics, MG-36, RO-77125, Bucharest (Romania)], E-mail: rodica.cristescu@inflpr.ro; Popescu, C.; Popescu, A.C.; Grigorescu, S.; Duta, L.; Mihailescu, I.N. [National Institute for Laser, Plasma and Radiation Physics, MG-36, RO-77125, Bucharest (Romania); Andronie, A.; Stamatin, I. [University of Bucharest, 3Nano-SAE Research Center, P.O. Box MG-11, Bucharest-Magurele (Romania); Ionescu, O.S.; Mihaiescu, D. [University of Agriculture Sciences and Veterinary Medicine, 59 Marasti, Bucharest (Romania); Buruiana, T. [Petru Poni Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda, 41A, Iasi (Romania); Chrisey, D.B. [Rensselaer Polytechnic Institute, Department of Material Science, 110 8th Street, Troy, NY 12180-3590 (United States)

    2009-03-01

    We report the deposition by MAPLE of: (i) a novel polyethylene glycol derivative with carboxyl functional groups and (ii) a block copolymer: poly(ethylene glycol)methyl ether-block-poly(caprolactone)-block-poly(ethylene glycol)methyl ether. We used a KrF* excimer laser source ({lambda} = 248 nm, {tau} = 25 ns, {nu} = 5 Hz). The laser fluence was set within the 200-700 mJ/cm{sup 2} range. The deposited thin films have been investigated by FTIR and AFM. We have concluded that the main functional groups of starting materials are present in the transferred film. We also examined the influence of laser fluence on both thin film structure and morphology.

  1. Active protein and calcium hydroxyapatite bilayers grown by laser techniques for therapeutic applications.

    Science.gov (United States)

    Motoc, M M; Axente, E; Popescu, C; Sima, L E; Petrescu, S M; Mihailescu, I N; Gyorgy, E

    2013-09-01

    Active protein and bioceramic calcium hydroxyapatite (HA) bilayers were grown by combining conventional pulsed laser deposition (PLD) and matrix-assisted pulsed laser evaporation (MAPLE) techniques. A pulsed UV KrF* excimer laser was used for the irradiations. The HA layers were grown by PLD. Proteins with antimicrobial action were attached to the bioceramic layers using MAPLE. The composite MAPLE targets were obtained by dissolving the proteins powder in distilled water. The crystalline status and chemical composition of the obtained structures were studied by X-ray diffractometry and Fourier transform infrared spectroscopy. The layers were grown for the design of advanced future metal implants coatings, ensuring both enhanced bone formation and localized antimicrobial therapy. Our results demonstrated that protein coatings improve bone cell proliferation in vitro. Immunofluorescence experiments show that actin filaments stretch throughout bone cells and sustain their optimal spreading. Copyright © 2013 Wiley Periodicals, Inc.

  2. Biocompatible and bioactive nanostructured glass coatings synthesized by pulsed laser deposition: In vitro biological tests

    Energy Technology Data Exchange (ETDEWEB)

    Popescu, A.C.; Sima, F.; Duta, L.; Popescu, C.; Mihailescu, I.N. [National Institute for Lasers, Plasma, and Radiation Physics, PO Box MG-54, RO-77125, Bucharest-Magurele (Romania); Capitanu, D. [S.C. Medical SRL, Nasta Hospital, Bucharest (Romania); Mustata, R.; Sima, L.E.; Petrescu, S.M. [Institute of Biochemistry, Romanian Academy, Splaiul Independentei 296, Bucharest (Romania); Janackovic, D. [Faculty of Technology and Metallurgy, Karnegijeva 4, 11000 Belgrade (Serbia)

    2009-03-01

    We report on the synthesis by pulsed laser deposition with a KrF* excimer laser source ({lambda} = 248 nm, {tau} = 25 ns) of bioglass thin films of 6P57 and 6P61 types. Physiology, viability, and proliferation of human osteoblast cells were determined by quantitative in vitro tests performed by flow cytometry on primary osteoblasts cultured on pulsed laser deposited bioglasses. Both types of glass films proved to be appropriate mediums for cell survival and proliferation. In a parallel investigation, cell morphology and adhesion to the surface was studied by fluorescence microscopy and scanning electron microscopy. Strong bonds between the materials and cells were found in both cases, as osteoblast pseudopodes penetrated deep into the material. According to our observations, the 6P57 glass films were superior with respect to viability and proliferation performances.

  3. Diagnostics of plasma plume produced by laser ablation using ICCD imaging and transient electrical probe technique

    Energy Technology Data Exchange (ETDEWEB)

    Mihaila, I; Ursu, C; Gegiuc, A; Popa, G, E-mail: ghpopa@uaic.r [Department of Physics, Faculty of Physics, ' Alexandru Ioan Cuza' University, 700506, Iasi (Romania)

    2010-01-01

    The dynamics of transient plasmas generated by high-fluence nanosecond laser ablation has been investigated by means of fast ICCD imaging and electrical probes in transient regime. Measurements have been carried out on plasmas produced in vacuum (5x 10{sup -6} Torr residual pressure) by a pulsed Excimer laser (20 ns, XeCl, {lambda}= 308 nm) irradiating stainless steel targets. Two plasma expansion velocities were estimated, one from probe measurements and another from recorded ICCD images. Electron plasma temperature (0.1 - 0.3 eV) and density (1 - 5x10{sup 11} cm{sup -3}) were measured by electrical probes for a laser radiation power density of 6x10{sup 8} W/cm{sup 2}.

  4. The spatial thickness distribution of metal films produced by large area pulsed laser deposition

    DEFF Research Database (Denmark)

    Pryds, Nini; Schou, Jørgen; Linderoth, Søren

    2007-01-01

    Thin films of metals have been deposited in the large-area Pulsed Laser Deposition (PLD) Facility at Riso National Laboratory. Thin films of Ag and Ni were deposited with laser pulses from an excimer laser at 248 nm with a rectangular beam spot at a fluence of 10 J/cm(2) on glass substrates of 127...... mm diameter positioned 80 turn from the target in vacuum. We have explored the distribution of deposited material on a stationary substrate from a fixed point of impact on the target relative to the substrate. In all cases the angular distribution of the deposited metal layers shows a distinct "flip...... utilized in an algorithm for production of films over large areas. (c) 2007 Elsevier B.V. All rights reserved....

  5. Deep Level Defects In Ion Implanted Laser Annealed Bulk GaAs

    Science.gov (United States)

    Dlodlo, Mqhele E.; Rys, Andrzej; Ahmed, Akhter U.; Edgar, James H.

    1990-02-01

    In this paper, we report on the carrier activation and deep level crystal defects in pulsed excimer laser (A = 308 nm) anealed samples of GaAs implanted with Si and Se to a dose ranging from 2.2 x 1012 to 6.0 x 10" cm'. The residual defects in the pulsed-laser annealed GaAs have been investigated by means of photo-induced current transient spectroscopy (PITS). The electron concentration and carrier mobility were studied by Hall effect and Van der Pauw measurements. Although the implanted layer recrystallization was good and the sheet carrier concentration was high, the electron mobility was low. The correlation between deep traps, the carrier concentration, the electron mobility, and laser light intensity is presented.

  6. Pulsed laser heating of silicon-nitride capped GaAs: Optical properties at high temperature

    Science.gov (United States)

    Bhat, A.; Yao, H. D.; Compaan, A.; Horak, A.; Rys, A.

    1988-09-01

    The optical properties of silicon nitride and gallium arsenide were studied at temperatures up to and beyond the melting point of GaAs by means of laser heating. XeCl excimer and pulsed dye laser pulses, ˜10 ns in duration, were used to heat the semiconductor under nitride capping layers of varying thickness. The transient reflectivity response at 514.5 nm was used together with a multilayer interference analysis to obtain the optical constants of solid and molten GaAs and of solid Si3N4 near the 1513-K melting point of GaAs. In addition, we report the melt duration as a function of laser pulse energy for GaAs with and without capping layers.

  7. Growth of metal-oxide semiconductor nanocomposite thin films by a dual-laser, dual target deposition system

    Energy Technology Data Exchange (ETDEWEB)

    Kompitsas, M. [Theor. and Phys./Chem. Institute, The National Hellenic Research Foundation, 48, Vasileos Konstantinou Ave., Athens 11635 (Greece)], E-mail: mcomp@eie.gr; Giannoudakos, A. [Theor. and Phys./Chem. Institute, The National Hellenic Research Foundation, 48, Vasileos Konstantinou Ave., Athens 11635 (Greece); Gyoergy, E. [Instituto de Ciencia de Materiales de Barcelona, Consejo Superior de Investigaciones Cientificas, Campus UAB, 08193 Bellaterra (Spain); National Institute for Lasers, Plasmas and Radiation Physics, Lasers Department, Bucharest 77125 (Romania); Sauthier, G.; Figueras, A. [Instituto de Ciencia de Materiales de Barcelona, Consejo Superior de Investigaciones Cientificas, Campus UAB, 08193 Bellaterra (Spain); Mihailescu, I.N. [National Institute for Lasers, Plasmas and Radiation Physics, Lasers Department, Bucharest 77125 (Romania)

    2007-10-15

    Nanocomposite formed by gold nanoparticles embedded in a titanium dioxide matrix thin films have been synthesized by a synchronized two laser system. An ArF* excimer ({lambda} = 193 nm, {tau}{sub FWHM} {approx} 12 ns) laser and a frequency tripled Nd:Yttrium Aluminium Garnet (YAG; {lambda} = 355 nm, {tau}{sub FWHM} {approx} 10 ns) laser were used for the irradiation of titanium dioxide and gold targets. The investigations showed that there exists the possibility for tailoring the optical properties of gold-titanium dioxide nanocomposites by the proper choice of the laser irradiation parameters. The band gap narrowing and additional absorption in the visible spectral region induced by the incorporation of gold in the host TiO{sub 2} matrix allows for the design of nanostructured thin films for new generation of photocatalysts or solar energy converters.

  8. Micro-optic fabrication using laser ablation process

    Science.gov (United States)

    Chang, Won-Seok; Yoon, Kyung-Ku; Kim, Jaegu; Shin, Bosung; Whang, Kyung-Hyun

    2002-09-01

    The feasibility of laser ablation in micro-machining of 3D structure of MEMS (Micro Electro Mechanical Systems) parts, specifically micro optics was studied in this paper. The micro-machining characteristics of polymer such as etching rate vs. energy fluence, number of pulse are investigated experimentally. The threshold energy density of polyurethane is about 30 mJ/cm2 and ablated depth per pulse can be precisely controlled in the range of 0.1-0.8μm by the attenuation of energy fluence. By mask moving technique, the micro prism, cylindrical lens and inclined surface were fabricated. These 3D structures can be used as master in electro-plating mold. This paper also summarized the work on the development of a simulation program for modeling the process of machining quasi-three dimensional shapes with the excimer laser beam on a constant moving polymer. Relatively simple masks of rectangle, triangle and half circle shape are considered. The etching depth is calculated by considering the number of laser pulses and the wavelength of laser beam irradiated on the various specimen surface such as PMMA, polyurethane and PI. It was found that similar shapes as experimental results, mask shape was designed to gain-lens surface which we want. As another method to manufacture micro lens the mask is made circular type and rotated during laser beam illumination. Opened mask area and scanning speed determine the surface shape of lens. Precise control of various parameters is admitted to fabricate micro optics.

  9. Thin-flap laser-assisted in situ keratomileusis.

    Science.gov (United States)

    Slade, Steven G

    2008-07-01

    Concerns regarding the increasing incidence of corneal ectasia following laser in situ keratomileusis procedures, together with increased understanding of the biomechanics of the cornea, has resulted in many refractive surgeons returning to surface ablation techniques such as photorefractive keratectomy. Even if surface ablation techniques offer a higher degree of safety than LASIK, they are associated with more pain and a slower visual recovery in the immediate postoperative period. This highlights the need for alternative procedures that offer the combined advantages of laser in situ keratomileusis and photorefractive keratectomy. Sub-Bowman's keratomileusis is a new procedure that provides the biomechanical stability and associated safety of photorefractive keratectomy with the visual results and reduced pain experience of laser in situ keratomileusis. This technique involves the use of the femtosecond laser to create a customized corneal flap of between 90 and 110 mum with a diameter based on the requirements of the individual patient and the type of excimer laser being used. This review outlines the rationale for sub-Bowman's keratomileusis and describes the efficacy, tolerability and safety of the procedure compared with photorefractive keratectomy.

  10. Synthesis and fluorescence studies of nine 1,5-benzodiazepine-2,4-dione derivatives: Dual emission and excimer fluorescence

    Science.gov (United States)

    Qomi, Hamid Reza; Habibi, Azizollah; Shahcheragh, Seyyed Mohammad

    2017-03-01

    The photophysical properties of nine 1,5-benzodiazepine-2,4-dione (BZD) derivatives were investigated using absorption and fluorescence spectral techniques in dimethyl sulfoxide. The trend of red shifts caused by the substitutions had full compliance with the trend of decreasing the calculated band gap (ΔELUMO-HOMO) by semi-empirical AM1 and DFT/B3LYP/6-311 + G* computational methods. The positive solvatochromism of BZD a demonstrated the π-π* nature of the singlet excited state. Dual fluorescence was observed in the emission spectra of BZD f and g, while their spectrum in different concentration showed only one peak short wavelength (SW) in dilute solutions. The main peak in SW around 370 nm was attributed to the monomer of BZD (f* or g*) and the broader emission shifted to the visible region around 400 nm in middle wavelength (MW) to the intermolecular excimer emission of BZD ([f/f]*or [g/g]*). The observed phenomena, such as solvatochromism, dual fluorescence, some red shifts caused by substitution, and larger Stokes shift indicated the existence of intramolecular charge transfer (ICT) in the BZDs series. The phosphorescence emission of the BZDs demonstrated their intersystem crossing (ISC) process.

  11. A battery-operated, stabilized, high-energy pulsed electron gun for the production of rare gas excimers.

    Science.gov (United States)

    Barcellan, L; Berto, E; Carugno, G; Galet, G; Galeazzi, G; Borghesani, A F

    2011-09-01

    We report on the design of a new type of hot-filament electron gun delivering fairly high current (a few hundreds of μ A) at high voltage (up to 100 kV) in continuous or pulsed mode. Its novel features are that the filament is heated by means of a pack of rechargeable batteries floated atop the high-voltage power supply in order to get rid of bulky isolation transformers, and that the filament current and, hence, the electron gun current, is controlled by a feedback circuit including a superluminescent diode decoupled from the high voltage by means of an optical fiber. This electron gun is intended for general purposes, although we have especially developed it to meet the needs of our experiment on the infrared emission spectroscopy of rare gas excimers. Our experiment requires that the charge injection into the sample is pulsed and constant and stable in time. The new electron gun can deliver several tens of nC per pulse of electrons of energy up to 100 keV into the sample cell. The new design also eliminates ripples in the emission current and ensures up to 12 h of stable performance. © 2011 American Institute of Physics

  12. Laser principles.

    Science.gov (United States)

    Bogdan Allemann, Inja; Kaufman, Joely

    2011-01-01

    Since the construction of the first laser in the 1960s, the role that lasers play in various medical specialities, including dermatology, has steadily increased. However, within the last 2 decades, the technological advances and the use of lasers in the field of dermatology have virtually exploded. Many treatments have only become possible with the use of lasers. Especially in aesthetic medicine, lasers are an essential tool in the treatment armamentarium. Due to better research and understanding of the physics of light and skin, there is now a wide and increasing array of different lasers and devices to choose from. The proper laser selection for each indication and treatment requires a profound understanding of laser physics and the basic laser principles. Understanding these principles will allow the laser operator to obtain better results and help avoid complications. This chapter will give an in-depth overview of the physical principles relevant in cutaneous laser surgery. Copyright © 2011 S. Karger AG, Basel.

  13. Hydroxyapatite thin films grown by pulsed laser deposition and matrix assisted pulsed laser evaporation: Comparative study

    Science.gov (United States)

    Popescu-Pelin, G.; Sima, F.; Sima, L. E.; Mihailescu, C. N.; Luculescu, C.; Iordache, I.; Socol, M.; Socol, G.; Mihailescu, I. N.

    2017-10-01

    Pulsed Laser Deposition (PLD) and Matrix Assisted Pulsed Laser Evaporation (MAPLE) techniques were applied for growing hydroxyapatite (HA) thin films on titanium substrates. All experiments were conducted in a reaction chamber using a KrF* excimer laser source (λ = 248 nm, τFWHM ≈ 25 ns). Half of the samples were post-deposition thermally treated at 500 °C in a flux of water vapours in order to restore crystallinity and improve adherence. Coating surface morphologies and topographies specific to the deposition method were evidenced by scanning electron, atomic force microscopy investigations and profilometry. They were shown to depend on deposition technique and also on the post-deposition treatment. Crystalline structure of the coatings evaluated by X-ray diffraction was improved after thermal treatment. Biocompatibility of coatings, cellular adhesion, proliferation and differentiation tests were conducted using human mesenchymal stem cells (MSCs). Results showed that annealed MAPLE deposited HA coatings were supporting MSCs proliferation, while annealed PLD obtained films were stimulating osteogenic differentiation.

  14. Four-order stiffness variation of laser-fabricated photopolymer biodegradable scaffolds by laser parameter modulation

    Energy Technology Data Exchange (ETDEWEB)

    Farkas, Balázs; Romano, Ilaria; Ceseracciu, Luca; Diaspro, Alberto [Department of Nanophysics, Istituto Italiano di Tecnologia (IIT), Via Morego 30, 16163 Genova (Italy); Brandi, Fernando [Department of Nanophysics, Istituto Italiano di Tecnologia (IIT), Via Morego 30, 16163 Genova (Italy); Istituto Nazionale di Ottica, Via Moruzzi 1, 56124 Pisa (Italy); Beke, Szabolcs, E-mail: szabolcs.beke@iit.it [Department of Nanophysics, Istituto Italiano di Tecnologia (IIT), Via Morego 30, 16163 Genova (Italy)

    2015-10-01

    The effects of various fabrication parameters of our Mask Projection Excimer Laser StereoLithography (MPExSL) system were investigated. We demonstrate that laser parameters directly change the physical properties (stiffness, thermal degradation, and height/thickness) of the poly(propylene fumarate) (PFF) scaffold structures. The tested parameters were the number of pulses, fluence per pulse and laser repetition rate. We present a four-order tuning capability of MPExSL-fabricated structures' stiffness without altering the resin composition or using cumbersome post-treatment procedures. Thermogravimetric analysis and differential scanning calorimetry confirmed this tuning capability. Prototype-segmented scaffold designs are presented and analyzed to further expand the concept and exploit this in situ stiffness tuning capability of the scaffolds for tissue engineering and regenerative medicine applications. - Highlights: • Facile stiffness control of scaffolds is beneficial in tissue engineering. • Four-order tuning capability of structures' stiffness is presented. • Scaffold's stiffness can be tuned in four orders (4 MPa–4 GPa). • All scaffolds have been fabricated from the same polymer resin in a broad stiffness range.

  15. Nanosecond laser nanostructuring of fused silica surfaces assisted by a chromium triangle template

    Science.gov (United States)

    Lorenz, P.; Grüner, C.; Frost, F.; Ehrhardt, M.; Zimmer, K.

    2017-10-01

    The well-reproducible, fast and cost-effective nanostructuring is a big challenge for laser methods. The laser nanostructuring of fused silica assisted by chromium nanotriangles was studied using a KrF excimer laser (λ = 248 nm, Δtp = 25 ns, top hat beam profile). Therefore, a fused silica substrate was covered with periodically ordered polystyrene (PS) spheres with a diameter of 1.59 μm. Subsequently, this system was covered with 30 nm chromium by electron beam evaporation. Afterwards the PS spheres were removed and the bare and resultant periodic Cr triangles were irradiated. The laser irradiation with high laser fluences resulted in a removal of the chromium and in localized modifications of the fused silica like a localized ablation of the fused silica. The resultant structures were studied by scanning electron (SEM) and atomic force microscopy (AFM) as well as the surface composition was analysed by energy-dispersive X-ray spectroscopy (EDX). The laser process allows the production of well-defined periodic hole structures into the fused silica surface where the resultant surface structure depends on the laser parameters. The multi-pulse irradiation of the Cr/SiO2 sample with moderate laser fluences (Φ ∼ 650 mJ/cm2) allows the fabrication of periodic pyramidal-like structures (depth Δz = 130 nm).

  16. Multi-criteria optimization in CO2 laser ablation of multimode polymer waveguides

    Science.gov (United States)

    Tamrin, K. F.; Zakariyah, S. S.; Sheikh, N. A.

    2015-12-01

    High interconnection density associated with current electronics products poses certain challenges in designing circuit boards. Methods, including laser-assisted microvia drilling and surface mount technologies for example, are being used to minimize the impacts of the problems. However, the bottleneck is significantly pronounced at bit data rates above 10 Gbit/s where losses, especially those due to crosstalk, become high. One solution is optical interconnections (OI) based on polymer waveguides. Laser ablation of the optical waveguides is viewed as a very compatible technique with ultraviolet laser sources, such as excimer and UV Nd:YAG lasers, being used due to their photochemical nature and minimal thermal effect when they interact with optical materials. In this paper, the authors demonstrate the application of grey relational analysis to determine the optimized processing parameters concerning fabrication of multimode optical polymer waveguides by using infra-red 10.6 μm CO2 laser micromachining to etch acrylate-based photopolymer (Truemode™). CO2 laser micromachining offers a low cost and high speed fabrication route needed for high volume productions as the wavelength of CO2 lasers can couple well with a variety of polymer substrates. Based on the highest grey relational grade, the optimized processing parameters are determined at laser power of 3 W and scanning speed of 100 mm/s.

  17. Pulsed laser deposition of pepsin thin films

    Energy Technology Data Exchange (ETDEWEB)

    Kecskemeti, G. [Department of Optics and Quantum Electronics, University of Szeged, H-6720 Szeged, Dom ter 9 (Hungary)]. E-mail: kega@physx.u-szeged.hu; Kresz, N. [Department of Optics and Quantum Electronics, University of Szeged, H-6720 Szeged, Dom ter 9 (Hungary); Smausz, T. [Hungarian Academy of Sciences and University of Szeged, Research Group on Laser Physics, H-6720 Szeged, Dom ter 9 (Hungary); Hopp, B. [Hungarian Academy of Sciences and University of Szeged, Research Group on Laser Physics, H-6720 Szeged, Dom ter 9 (Hungary); Nogradi, A. [Department of Ophthalmology, University of Szeged, H-6720, Szeged, Koranyi fasor 10-11 (Hungary)

    2005-07-15

    Pulsed laser deposition (PLD) of organic and biological thin films has been extensively studied due to its importance in medical applications among others. Our investigations and results on PLD of a digestion catalyzing enzyme, pepsin, are presented. Targets pressed from pepsin powder were ablated with pulses of an ArF excimer laser ({lambda} = 193 nm, FWHM = 30 ns), the applied fluence was varied between 0.24 and 5.1 J/cm{sup 2}. The pressure in the PLD chamber was 2.7 x 10{sup -3} Pa. The thin layers were deposited onto glass and KBr substrates. Our IR spectroscopic measurements proved that the chemical composition of deposited thin films is similar to that of the target material deposited at 0.5 and 1.3 J/cm{sup 2}. The protein digesting capacity of the transferred pepsin was tested by adapting a modified 'protein cube' method. Dissolution of the ovalbumin sections proved that the deposited layers consisted of catalytically active pepsin.

  18. Applications of laser lithography on oxide film to titanium micromachining

    Science.gov (United States)

    Chauvy, P.-F.; Hoffmann, P.; Landolt, D.

    2003-03-01

    Due to its good biocompatibility titanium is widely used for dental and orthopaedics implants and for biomedical microsystems. For these applications one needs specific micromachining methods. A new four-step method for electrochemical micromachining of titanium is presented here, which implies anodic oxidation, Excimer laser sensitising irradiation, anodic dissolution, and ultrasonic cleaning. The method is applied to the fabrication of two 3D model structures, surface structuring of a cylinder and machining of a complex two-level architecture. The absence of debris and of a heat affected zone as well as the resulting surface smoothness are the main advantages of the process. Ways to improve the still limited processing speed are discussed with regards to potential applications.

  19. The development of laser surgery and medicine in China

    Science.gov (United States)

    Chen, Mingzhe

    2005-07-01

    acne scar, osmidrosis etc. For ophthalmology, excimer laser are used for myopia or hyperopia; argon green laser, krypton yellow laser are adopted in coagulation for retinal detachment and neovascularization etc. Lasers are often used for the canaliculoplasty in the lacrimal canal. Low level lasers had been used very often on the acupuncture points and for many chronic diseases. Intravascular low level laser irradiation adopting semiconductor lasers and He-Ne laser were reported to use for comatose patients, schizophrenia, vascular dementia, Alzeimer"s disease and coronary disease. Reports from laboratory studies in the field of low level laser demonstrated the stimulation effect on the cells and immunology system; inhibitory effect on proliferation; it improved the biomedical data in hemorrheology; promoted the spinal motor nerve cell function, axonal regeneration; increased epidermal Langerhams cell to improve the antigen function, increased myocardial capillary permeability. Intra-coronary low power red laser irradiation assisted coronary interventional therapy showed its prevention effect on restenosis. Studies about the effects of various kinds of lasers, their wavelength, power densities and doses on various kinds of tissues were reported.

  20. Ultraviolet laser patterning of porous silicon

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Fidel, E-mail: fvega@oo.upc.edu [Departament d' Òptica i Optometria, UPC, Violinista Vellsolà 37, 08222 Terrasa (Spain); Peláez, Ramón J.; Kuhn, Timo; Afonso, Carmen N. [Laser Processing Group, Instituto de Óptica, CSIC, Serrano 121, 28006 Madrid (Spain); Recio-Sánchez, Gonzalo; Martín-Palma, Raúl J. [Departamento de Física Aplicada, UAM, Campus de Cantoblanco, 28049 Madrid (Spain)

    2014-05-14

    This work reports on the fabrication of 1D fringed patterns on nanostructured porous silicon (nanoPS) layers (563, 372, and 290 nm thick). The patterns are fabricated by phase-mask laser interference using single pulses of an UV excimer laser (193 nm, 20 ns pulse duration). The method is a single-step and flexible approach to produce a large variety of patterns formed by alternate regions of almost untransformed nanoPS and regions where its surface has melted and transformed into Si nanoparticles (NPs). The role of laser fluence (5–80 mJ cm{sup −2}), and pattern period (6.3–16 μm) on pattern features and surface structuring are discussed. The results show that the diameter of Si NPs increases with fluence up to a saturation value of 75 nm for a fluence ≈40 mJ cm{sup −2}. In addition, the percentage of transformed to non-transformed region normalized to the pattern period follows similar fluence dependence regardless the period and thus becomes an excellent control parameter. This dependence is fitted within a thermal model that allows for predicting the in-depth profile of the pattern. The model assumes that transformation occurs whenever the laser-induced temperature increase reaches the melting temperature of nanoPS that has been found to be 0.7 of that of crystalline silicon for a porosity of around 79%. The role of thermal gradients across the pattern is discussed in the light of the experimental results and the calculated temperature profiles, and shows that the contribution of lateral thermal flow to melting is not significant for pattern periods ≥6.3 μm.

  1. Detection of Membrane Fluidity in Submitochondrial Particles of Platelets and Erythrocyte Membranes from Mexican Patients with Alzheimer Disease by Intramolecular Excimer Formation of 1,3 Dipyrenylpropane

    Directory of Open Access Journals (Sweden)

    G.G. Ortiz

    2008-01-01

    Full Text Available It has been suggested that mitochondrial dysfunction and defects in membrane structure could be implied in AD pathogenesis. The aim of the present work was the study of membrane fluidity in submitochondrial platelet particles and erythrocyte membranes from Mexican patients. Blood samples were obtained from 30 patients with Alzheimer disease and 30 aged-matched control subjects. Membrane fluidity determinations were done using a very low concentration of the fluorescent dipyrenylpropane probe incorporated in both types of membranes. This probe is able to give excimer and monomer fluorescence, therefore it can be used to monitor fluidity changes in biological membranes.

  2. 158. Extracción quirúrgica de electrodos de marcapasos y desfibrilador asistida con láser excimer

    Directory of Open Access Journals (Sweden)

    V.X. Mosquera Rodríguez

    2012-04-01

    Conclusiones: El láser Excimer se presenta como una alternativa eficaz para la extracción de electrodos intravasculares con resultados excelentes en nuestra serie, permitiendo tratar algunos pacientes que difícilmente podrían ser abordados con otras técnicas existentes. El riesgo de complicaciones cardiovasculares mayores exige que la técnica sea efectuada bajo anestesia general en un quirófano habilitado para cirugía cardíaca.

  3. Surface modification of Sylgard 184 polydimethylsiloxane by 254 nm excimer radiation and characterization by contact angle goniometry, infrared spectroscopy, atomic force and scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Waddell, Emanuel A. [University of Alabama in Huntsville, Huntsville, AL (United States)], E-mail: ewaddell@chemistry.uah.edu; Shreeves, Stephen [University of Alabama in Huntsville, Huntsville, AL (United States); Carrell, Holly; Perry, Christopher [Oakwood College, Huntsville, AL (United States); Reid, Branden A. [Morgan State University, Baltimore, MD (United States); McKee, James [University of Alabama in Birmingham, Birmingham, AL (United States)

    2008-06-30

    The modification of polydimethylsiloxane (PDMS) by narrow band 254 nm excimer radiation under a nitrogen atmosphere was characterized by contact angle goniometry, attenuated total reflectance infrared spectroscopy, atomic force and scanning electron microscopy. UV irradiation results in the formation of the carboxylic acids that influences the wettability of the surface. Continued exposure results in the formation of an inorganic surface (SiO{sub x} (1 < x < 2)) which hinders the ability to continually increase the wettability. The continuity of this inorganic layer is disrupted by the formation of surface cracks. These results have implications in the fabrication and chemical modification of microfluidic or micro-electro-mechanical systems.

  4. Surface modification of Sylgard 184 polydimethylsiloxane by 254 nm excimer radiation and characterization by contact angle goniometry, infrared spectroscopy, atomic force and scanning electron microscopy

    Science.gov (United States)

    Waddell, Emanuel A.; Shreeves, Stephen; Carrell, Holly; Perry, Christopher; Reid, Branden A.; McKee, James

    2008-06-01

    The modification of polydimethylsiloxane (PDMS) by narrow band 254 nm excimer radiation under a nitrogen atmosphere was characterized by contact angle goniometry, attenuated total reflectance infrared spectroscopy, atomic force and scanning electron microscopy. UV irradiation results in the formation of the carboxylic acids that influences the wettability of the surface. Continued exposure results in the formation of an inorganic surface (SiO x (1 < x < 2)) which hinders the ability to continually increase the wettability. The continuity of this inorganic layer is disrupted by the formation of surface cracks. These results have implications in the fabrication and chemical modification of microfluidic or micro-electro-mechanical systems.

  5. Influence of the gas mixture radio on the correlations between the excimer XeCl emission and the sealed gas temperature in dielectric barrier discharge lamps

    CERN Document Server

    Xu Jin Zhou; Ren Zhao Xing

    2002-01-01

    For dielectric barrier discharge lamps filled with various gas mixture ratios, the correlations between the excimer XeCl emission and the sealed gas temperature have been founded, and a qualitative explication is presented. For gas mixture with chlorine larger than 3%, the emission intensity increases with the sealed gas temperature, while with chlorine about 2%, the emission intensity decreases with the increasing in the gas temperature, and could be improved by cooling water. However, if chlorine is less than 1.5%, the discharge appears to be a mixture mode with filaments distributed in a diffused glow-like discharge, and the UV emission is independent on the gas temperature

  6. Laser synthesized super-hydrophobic conducting carbon with broccoli-type morphology as a counter-electrode for dye sensitized solar cells

    Science.gov (United States)

    Gokhale, Rohan; Agarkar, Shruti; Debgupta, Joyashish; Shinde, Deodatta; Lefez, Benoit; Banerjee, Abhik; Jog, Jyoti; More, Mahendra; Hannoyer, Beatrice; Ogale, Satishchandra

    2012-10-01

    A laser photochemical process is introduced to realize superhydrophobic conducting carbon coatings with broccoli-type hierarchical morphology for use as a metal-free counter electrode in a dye sensitized solar cell. The process involves pulsed excimer laser irradiation of a thin layer of liquid haloaromatic organic solvent o-dichlorobenzene (DCB). The coating reflects a carbon nanoparticle-self assembled and process-controlled morphology that yields solar to electric power conversion efficiency of 5.1% as opposed to 6.2% obtained with the conventional Pt-based electrode.A laser photochemical process is introduced to realize superhydrophobic conducting carbon coatings with broccoli-type hierarchical morphology for use as a metal-free counter electrode in a dye sensitized solar cell. The process involves pulsed excimer laser irradiation of a thin layer of liquid haloaromatic organic solvent o-dichlorobenzene (DCB). The coating reflects a carbon nanoparticle-self assembled and process-controlled morphology that yields solar to electric power conversion efficiency of 5.1% as opposed to 6.2% obtained with the conventional Pt-based electrode. Electronic supplementary information (ESI) available: Materials and equipment details, solar cell fabrication protocol, electrolyte spreading time measurement details, XPS spectra, electronic study, film adhesion test detailed analysis and field emission results. See DOI: 10.1039/c2nr32082g

  7. Ellipsometric characterization of AlN films synthesized by Pulsed-Laser-Deposition

    Energy Technology Data Exchange (ETDEWEB)

    Szekeres, A; Vlaikova, E; Cziraki, A; Petrik, P; Socol, G; Ristoscu, C; Mihailescu, I N, E-mail: szekeres@issp.bas.b

    2010-11-01

    AlN films were synthesized on Si(100) by pulsed laser deposition at 800{sup o}C and different incident laser fluences in vacuum and in nitrogen at 0.1 Pa. Two KrF* ({lambda} = 248 nm) excimer laser sources were used generating pulses of 7.4 and 25 ns duration, respectively. The incident laser intensity on target was kept constant in all experiments within (3-4)x10{sup 8} W/cm{sup 2}. The films were studied by ellipsometry (SE) in the spectral range {lambda} = 190 to 900 nm and the optical parameters, such as refractive index, high frequency dielectric constant and single oscillator energies were estimated. The analysis of the SE results revealed that the films, deposited with short laser pulses and low laser fluence (3.7 J/cm{sup 2}) were characterized with refractive index values higher than 2 and an optical band gap energy value of {approx} 5 eV, suggesting that their structure was polycrystalline with cubic crystallites. With longer laser pulses and large fluence the refractive index values decreased and the values of the energetic parameters increased suggesting that the films, deposited in vacuum were polycrystalline with hexagonal phase, while those, deposited in nitrogen at 0.1 Pa were amorphous.

  8. High-repetition rate UV lasers with inductive-capacitive discharge stabilization

    Science.gov (United States)

    Andramanov, A. V.; Kabaev, S. A.; Lazhintsev, B. V.; Nor-Arevyan, V. A.; Pisetskaya, A. V.; Selemir, V. D.

    2007-04-01

    The high repetition rate UV lasers (XeF [1], KrF [2] and N II) with a new electrode unit are investigated. A multisectional discharge gap 25 cm length and 1.2 cm height is formed by 25 pairs of anode-cathode plates. The discharge width is ~ 1 mm. The average specific pump power is ~ 9 MW cm -3. The main aim of the work is the achievement of a maximum pulse repetition rate (f m) with high output energy stability. At a rather low gas flow velociity <= 19 m s -1 the frequencies f as high as 4 kHz in the excimer lasers and 4.5 kHz in a nitrogen laser are realized. The relative rms deviations of the output energy (σ) for XeF and KrF lasers is in the range 1-2% for f <= 3 kHz and 3-4% for f = 4 kHz. For the nitrogen laser σ <= 1.3% is at f <= 4.5 κΓ\\tscy.The average output power 10 (12) W for the XeF (KrF) laser and 1.1 W for the nitrogen laser are reached.

  9. High-fidelity modelling of an exciplex pumped alkali laser with radiative transport

    Energy Technology Data Exchange (ETDEWEB)

    Palla, Andrew D; Carroll, David L; Verdeyen, Joseph T [CU Aerospace, Champaign, IL 61820 (United States); Heaven, Michael C, E-mail: apalla@cuaerospace.com [Department of Chemistry, Emory University, Atlanta, GA 30322 (United States)

    2011-07-14

    The exciplex-pumped alkali laser (XPAL) system has been demonstrated in mixtures of Cs vapour, Ar, and ethane by pumping Cs-Ar atomic collision pairs and subsequent dissociation of diatomic, electronically excited CsAr molecules (exciplexes or excimers). Because of the addition of atomic collision pairs and exciplex states, modelling of the XPAL system is far more complicated than the modelling of the classic diode-pumped alkali laser (DPAL). In this paper, we discuss BLAZE-V time-dependent multi-dimensional modelling of this new laser system including radiative transport and parasitic loss effects. A two-dimensional, time-dependent baseline simulation of a pulsed XPAL is presented and compared to data. Good agreement is achieved on a laser pulse full width at half-maximum and laser pulse rise time. Parametric simulations of pulsed XPAL system configurations similar to that of the baseline case, given both four- and five-level laser operation, are presented in which good agreement is obtained with outcoupled laser energy as a function of absorbed pump energy data. The potential impact of parasitic losses on modelled system configurations is discussed.

  10. Laser-assisted metal deposition from liquid-phase precursors on polymers

    Science.gov (United States)

    Kordás, K.; Békési, J.; Vajtai, R.; Nánai, L.; Leppävuori, S.; Uusimäki, A.; Bali, K.; George, Thomas F.; Galbács, G.; Ignácz, F.; Moilanen, P.

    2001-03-01

    In this work, a short review is presented for results utilizing the technique of laser-assisted metallization of dielectrics. Experimental efforts and results related to the metal (palladium (Pd), copper (Cu) and silver (Ag)) deposition on polymeric materials (polyimide (PI), mylar) are reported. These polymers and metals are chosen due to their growing importance in the rapidly-developing microelectronics packaging industry. The method of laser-induced chemical liquid-phase deposition (LCLD) offers many advantages compared to other techniques such as laser-induced forward transfer (LIFT), pulsed-laser deposition (PLD) and laser-assisted chemical vapor-phase deposition (LCVD). The LCLD is time and cost effective because vacuum tools and special pre-treatments are not required. The consumed chemicals used in precursors are non-harmful and easy to handle due to the liquid phase. For the optimal physical and chemical properties of deposits, the laser and solution parameters are varied. XeCl and KrF excimer and Ar + lasers are employed for executing the palladium, Ag and/or Cu formation on the polymer substrates. Chemical and physical analyses of the formed metal patterns are performed by EDX, XRD, FESEM, SEM, resistance and adhesion measurements.

  11. Visible photo- and electro-luminescence from laser-crystallized a-Si:H and its based multilayers

    Science.gov (United States)

    Chen, Kun-Ji; Wu, Wei; Huang, Xinfan; Li, Zhifeng; Wang, Mingxiang; Xu, Jun; Li, Wei; Feng, Duan

    1996-09-01

    We have reported for the first time on visible photoluminescence (PL) in crystallized a-Si:H/aSiNx:H multilayers structure by CW Ar ion laser annealing treatments. In this paper we present new results on visible PL and electroluminescence (EL) from crystallized a:SiH and its based multilayers by using KrF excimer pulse laser irradiating treatments. Strong and stable PL and EL have been observed by naked eye in both laser irradiated a-Si:H and a-Si:H/aSiNx:H multilayers samples at room temperature. The EL peak of crystallized a-Si:H/a-SiNx:H multilayers is blue shifted from 1.79 eV to 2.00 eV with narrowing the well layer thickness from 4 nm to 2 nm which suggests the origin of the light emission should be related to the quantum size effect.

  12. Antimicrobial activity of biopolymer–antibiotic thin films fabricated by advanced pulsed laser methods

    Energy Technology Data Exchange (ETDEWEB)

    Cristescu, R., E-mail: rodica.cristescu@inflpr.ro [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, P.O. Box MG-36, Bucharest-Magurele (Romania); Popescu, C.; Dorcioman, G.; Miroiu, F.M.; Socol, G.; Mihailescu, I.N. [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, P.O. Box MG-36, Bucharest-Magurele (Romania); Gittard, S.D.; Miller, P.R.; Narayan, R.J. [Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, NC 27599-7575 (United States); Enculescu, M. [National Institute for Materials Physics, PO Box MG-7, Bucharest-Magurele (Romania); Chrisey, D.B. [Tulane University, Department of Physics and Engineering Physics, New Orleans, LA (United States)

    2013-08-01

    We report on thin film deposition by matrix assisted pulsed laser evaporation (MAPLE) of two polymer–drug composite thin film systems. A pulsed KrF* excimer laser source (λ = 248 nm, τ = 25 ns, ν = 10 Hz) was used to deposit composite thin films of poly(D,L-lactide) (PDLLA) containing several gentamicin concentrations. FTIR spectroscopy was used to demonstrate that MAPLE-transferred materials exhibited chemical structures similar to those of drop cast materials. Scanning electron microscopy data indicated that MAPLE may be used to fabricate thin films of good morphological quality. The activity of PDLLA–gentamicin composite thin films against Staphylococcus aureus bacteria was demonstrated using drop testing. The influence of drug concentration on microbial viability was also assessed. Our studies indicate that polymer–drug composite thin films prepared by MAPLE may be used to impart antimicrobial activity to implants, medical devices, and other contact surfaces.

  13. Antimicrobial activity of biopolymer-antibiotic thin films fabricated by advanced pulsed laser methods

    Science.gov (United States)

    Cristescu, R.; Popescu, C.; Dorcioman, G.; Miroiu, F. M.; Socol, G.; Mihailescu, I. N.; Gittard, S. D.; Miller, P. R.; Narayan, R. J.; Enculescu, M.; Chrisey, D. B.

    2013-08-01

    We report on thin film deposition by matrix assisted pulsed laser evaporation (MAPLE) of two polymer-drug composite thin film systems. A pulsed KrF* excimer laser source (λ = 248 nm, τ = 25 ns, ν = 10 Hz) was used to deposit composite thin films of poly(D,L-lactide) (PDLLA) containing several gentamicin concentrations. FTIR spectroscopy was used to demonstrate that MAPLE-transferred materials exhibited chemical structures similar to those of drop cast materials. Scanning electron microscopy data indicated that MAPLE may be used to fabricate thin films of good morphological quality. The activity of PDLLA-gentamicin composite thin films against Staphylococcus aureus bacteria was demonstrated using drop testing. The influence of drug concentration on microbial viability was also assessed. Our studies indicate that polymer-drug composite thin films prepared by MAPLE may be used to impart antimicrobial activity to implants, medical devices, and other contact surfaces.

  14. UV-femtosecond laser ablation of SrTiO3 single crystals

    Science.gov (United States)

    Zoppel, S.; Gray, D.; Farsari, M.; Merz, R.; Reider, G. A.; Fotakis, C.

    2007-04-01

    We have investigated the ablation behaviour of single crystal SrTiO3 with focus on the influence of the pulse duration at a wavelength of 248 nm. The experiments were performed with KrF-excimer lasers with pulse durations of 34 ns and 500 fs, respectively. Femtosecond-ablation turns out to be more efficient by one order of magnitude and to eliminate the known problem of cracking of SrTiO3 during laser machining with longer pulses [1],[2]. In addition, the cavities ablated with femtosecond pulses display a smoother surface with no indication of melting and well-defined, sharp edges. These effects can be explained by the reduced thermal shock effect on the material by using ultrashort pulses.

  15. In situ electron spectroscopic identification of carbon species deposited by laser ablation

    Energy Technology Data Exchange (ETDEWEB)

    Samano, E.C.; Gamietea, A.; Cota, L. [IFUNAM, Ensenada (Mexico). Lab. de Ensenada; Soto, G. [IFUNAM, Ensenada (Mexico). Lab. de Ensenada]|[Centro de Investigacion Cientifica y de Educacion Superior de Ensenada (Mexico). Programa de Posgrado en Fisica de Materiales

    1997-05-01

    Thin carbon films were grown on Si (111) substrates by ablating a graphite target utilizing an excimer pulsed laser in a UHV Riber {copyright} LDM-32 system. Two kinds of films were produced, a highly oriented pyrolytic graphite (HOPG) type and a diamond-like carbon (DLC) type. A relationship of the films microstructure with laser power density and substrate conditions was observed. The HOPG films were homogeneous but the DLC films were heterogeneous, as shown by micrographs. The thin films are monitored and analyzed in situ during the first stages of the deposition process. The monitoring was done by RHEED and the characterization by several surface spectroscopic techniques, AES, XPS and EELS. The formation of a SiC interface was observed for both films due to the reaction of the first carbon species with the substrate surface.

  16. A method of atmospheric density measurements during Shuttle entry using UV laser Rayleigh scattering

    Science.gov (United States)

    Mckenzie, Robert L.

    1987-01-01

    A detailed study is described of the performance capabilities and the hardware requirements for a method in which ambient density is measured along the Space Shuttle flight path using on-board optical instrumentation. The technique relies on Rayleigh scattering of light from a pulsed, ultraviolet, ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing direct measurements of ambient density with an uncertainty of less than 1 percent and with a spatial resolution of 1 km, over an altitude range from 50 to 90 km. In addition, extensions of this concept are discussed that allow measurements of the shock wave location and the density profile within the shock layer. Two approaches are identified that appear to be feasible, in which the same laser system is used for the extended measurements as that required for the ambient density measurements.

  17. Plasmonic response and transformation mechanism upon single laser exposure of metal discontinuous films

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez, C.E. [Laser Processing Group, Instituto de Óptica, CSIC, Serrano 121, 28006 Madrid (Spain); Peláez, R.J., E-mail: rpelaez@io.cfmac.csic.es [Laser Processing Group, Instituto de Óptica, CSIC, Serrano 121, 28006 Madrid (Spain); Afonso, C.N. [Laser Processing Group, Instituto de Óptica, CSIC, Serrano 121, 28006 Madrid (Spain); Riedel, S.; Leiderer, P. [Faculty of Physics, University of Konstanz, Universitätsstraße 10, 78457 Konstanz (Germany); Jimenez-Rey, D.; Font, A. Climent- [Centro de Micro-Análisis de Materiales (CMAM) and Departamento de Física Aplicada, University Autonoma Madrid, 28049 Madrid (Spain)

    2014-05-01

    Ag and Au discontinuous films were exposed to single nanosecond pulses of a homogenized beam of an excimer laser operating at 193 nm. For low fluences, the films convert into big, almost spherical and isolated nanoparticles (NPs) due to laser-induced dewetting. Their optical response exhibits a sharp surface plasmon resonance (SPR) consistent with that of spherical and non-interacting NPs. For higher fluences, the formation of many small NPs and almost no big NPs is observed instead. The SPR features change and the plasmonic response becomes influenced by multipolar interactions among neighbouring NPs. Low and high fluence regimes are respectively related to melting and boiling threshold of the metal, and additionally, craters appear in the latter regime.

  18. Monitoring laser cleaning of titanium alloys by probe beam reflection and emission spectroscopy

    Science.gov (United States)

    Whitehead, D. J.; Crouse, P. L.; Schmidt, M. J. J.; Li, L.; Turner, M. W.; Smith, A. J. E.

    2008-10-01

    Studies have shown excimer laser cleaning to be an effective non-chemical alternative method for removing contaminants from surfaces of titanium alloys in preparation for electron beam welding and diffusion bonding, with reference to aerospace applications. Among several important criteria for process acceptability, is the absence of oxide formation. This paper investigates the viability of using a probe beam reflection (PBR) system and laser plume emission spectroscopy (PES) for detection of incipient oxide formation on three typical aerospace titanium alloys, viz. Ti64, Ti6246, and IMI834. These diagnostic techniques have been shown to be capable of sensing different components in the emission plume and yield quantitative results. Results from this work correlate closely with previously reported cleaning mechanisms. The oxidation threshold, as well as the operating window for successful decontamination, is discussed.

  19. From small aromatic molecules to functional nanostructured carbon by pulsed laser-induced photochemical stitching

    Directory of Open Access Journals (Sweden)

    R. R. Gokhale

    2012-06-01

    Full Text Available A novel route employing UV laser pulses (KrF Excimer, 248 nm to cleave small aromatic molecules and stitch the generated free radicals into functional nanostructured forms of carbon is introduced. The process differs distinctly from any strategies wherein the aromatic rings are broken in the primary process. It is demonstrated that this pulsed laser-induced photochemical stitching (PLPS process when applied to routine laboratory solvents (or toxic chemical wastes when discarded Chlorobenzene and o-Dichlorobenzene yields Carbon Nanospheres (CNSs comprising of graphene-like sheets assembled in onion-like configurations. This room temperature process implemented under normal laboratory conditions is versatile and clearly applicable to the whole family of haloaromatic compounds without and with additions of precursors or other nanomaterials. We further bring out its applicability for synthesis of metal-oxide based carbon nanocomposites.

  20. Interaction of power pulses of laser radiation with glasses containing implanted metal nanoparticles

    CERN Document Server

    Stepanov, A L; Hole, D E; Bukharaev, A A

    2001-01-01

    The sodium-calcium silicate glasses, implanted by the Ag sup + ions with the energy of 60 keV and the dose of 7 x 10 sup 1 sup 6 cm sup - sup 2 by the ion current flux density of 10 mu A/cm sup 2 , are studied. The ion implantation makes it possible to synthesize in the near-the-surface glass area the composite layer, including the silver nanoparticles. The effect of the powerful pulse excimer laser on the obtained composite layer is investigated. It is established that the laser radiation leads to decrease in the silver nanoparticles size in the implanted layer. However nonuniform distribution of particles by size remains though not so wide as before the irradiation. The experimental results are explained by the effect of glass and metallic particles melting in the nanosecond period of time

  1. Overview of commercially available femtosecond lasers in refractive surgery.

    Science.gov (United States)

    Lubatschowski, Holger

    2008-01-01

    To report on four different commercially available femtosecond laser systems used in refractive surgery. Four systems were analyzed: Ziemer DaVinci system, Zeiss VisuMax, IntraLase FS laser, and 20/10 Perfect Vision FEMTEC. The DaVinci system attracts attention with its concept of low laser pulse energy and flexible mirror arm as a beam delivery. The low pulse energy makes it compact and robust, because only an oscillator as a laser source is required. Another important feature of the low energy pulses is the reduced bubble formation during the cutting process. The smaller the bubbles, the more precise the cut can be positioned. However, the compact setup limits the system in its flexibility in cutting geometry. The VisuMax also uses the new generation of femtosecond technology, which should make it more immune to environmental and temperature changes. However, it is a bulky system, and the patient has to be moved to the excimer laser system after the flap is created. The IntraLase is the laser with the most clinical experience by far, which should be an important issue in terms of safety and technical support. On the other hand, it uses older femtosecond laser technology. This technology is sensitive to changes in temperature or humidity, which can be an important factor if the surgical environment is not air conditioned. The 20/10 Perfect Vision FEMTEC system is comparable with the IntraLase with respect to its technical parameters. However, no data are available about the amount of clinical experience. Although the systems are based on the same principle of photodisruption in corneal tissue, differences exist regarding the concept of these devices.

  2. Laser-assisted cavity preparation and adhesion to erbium-lased tooth structure: part 1. Laser-assisted cavity preparation.

    Science.gov (United States)

    De Moor, Roeland Jozef Gentil; Delmé, Katleen Ilse Maria

    2009-12-01

    The use of the ruby laser (693.4 nm) was first described in 1960, and it was applied for hard tissue ablation in 1964. Different wavelengths [Nd:YAG (1.065 microm), CO2 (9.6 microm), Ho:YAG (2.12 microm)] were consequently explored. Due to massive thermal side effects, these wavelengths caused increased temperature in dental pulp, as well as microcracks and carbonization. The use of this laser for dental hard tissue preparation was eventually abandoned. At the end of the 1980s, excimer lasers (ultraviolet) and the erbium laser (infrared) were developed, with the advantages of improved temperature control and smaller penetration depths. With the development of smaller devices and improved knowledge of how to limit damage to the surrounding tissues, new ablation techniques were established in the 1990s. There is still contradiction in the current literature, however, in that different wavelengths are advocated for hard tissue removal, and heterogeneity in laser parameters and power densities remain. In this review, the effects of the wavelengths presently used for cavity preparation are evaluated. We conclude that erbium lasers (Er:YAG and Er,Cr:YSGG) are most efficient and, with the right parameters, the thermal side effects are small. There is a substantial need for "gold standards", although this is difficult to establish in practice owing to different laser parameters (including pulse repetition rate, amount of cooling, energy delivered per pulse, and types of pulses) and target specificity (tissue interaction with sound or decayed enamel or dentin, and the extent of (de)mineralization) which influence tissue interaction.

  3. Lasers technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-01

    The Laser Technology Program of IPEN is developed by the Center for Lasers and Applications (CLA) and is committed to the development of new lasers based on the research of new optical materials and new resonator technologies. Laser applications and research occur within several areas such as Nuclear, Medicine, Dentistry, Industry, Environment and Advanced Research. Additional goals of the Program are human resource development and innovation, in association with Brazilian Universities and commercial partners.

  4. Detection of Membrane Fluidity in Submitochondrial Particles of Platelets and Erythrocyte Membranes from Mexican Patients with Alzheimer Disease by Intramolecular Excimer Formation of 1,3 Dipyrenylpropane

    Science.gov (United States)

    Ortiz, G.G.; Pacheco-Moisés, F.; El Hafidi, M.; Jiménez-Delgado, A.; Macías-Islas, M. A.; Corral, S. A. Rosales; de la Rosa, A. Célis; Sánchez-González, V. J.; Arias-Merino, E. D.; Velázquez-Brizuela, I. E.

    2008-01-01

    It has been suggested that mitochondrial dysfunction and defects in membrane structure could be implied in AD pathogenesis. The aim of the present work was the study of membrane fluidity in submitochondrial platelet particles and erythrocyte membranes from Mexican patients. Blood samples were obtained from 30 patients with Alzheimer disease and 30 aged-matched control subjects. Membrane fluidity determinations were done using a very low concentration of the fluorescent dipyrenylpropane probe incorporated in both types of membranes. This probe is able to give excimer and monomer fluorescence, therefore it can be used to monitor fluidity changes in biological membranes. The data obtained showed that in submitochondrial particles from AD patients, the excimer to monomer fluorescent intensity ratio was lower (0.231 ± 0.008) than aged-matched control subjects (0.363 ± 0.014). Therefore, membrane fluidity was lower in AD samples. On the other hand, we found similar membrane fluidity in erythrocytes from AD patients and aged-matched controls: the fluorescent intensity ratios were 0.312 ± 0.03 and 0.305 ± 0.033, respectively. In addition, lipid peroxidation in submitochondrial particles and erythrocyte membranes was higher in AD samples than in aged-matched controls. These data suggest that submitochondrial platelet particles are more sensitive to oxidative stress than erythrocyte membranes. PMID:18334736

  5. Laser handbook

    CERN Document Server

    Bass, Michael

    1985-01-01

    Volume 4 of the Laser Handbook continues the high standard set by the first three volumes which were widely acclaimed by numerous reviewers in Science, Optical Spectra and Laser Technology, as presenting an outstanding contribution to the field of laser technology.

  6. Microchip Lasers

    Science.gov (United States)

    2016-10-31

    USA E-mail: zayhowski@ll.mit.edu Abstract Microchip lasers are a rich family of solid-state lasers defined by their small size, robust integration...reliability, and potential for low-cost mass production. Continuous-wave microchip lasers cover a wide range of wavelengths, often operate single

  7. Lasers (Rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Hal

    1969-01-01

    A laser is an instrument that produces an enormously intense pencil-thin beam of light. In this booklet we shall learn what there is about the laser that gives it so much promise. We shall investigate what it is, how it works, and the different kinds of lasers there are.

  8. Femtosecond laser versus mechanical microkeratome: a retrospective comparison of visual outcomes at 3 months.

    Science.gov (United States)

    Tanna, Mesha; Schallhorn, Steven C; Hettinger, Keith A

    2009-07-01

    To compare the visual outcomes of LASIK procedures in which flaps were created with a femtosecond laser (IntraLase FS 60Hz, Abbott Medical Optics [AMO]) to procedures in which flaps were created with a mechanical microkeratome (Moria Evo3 One Use-Plus, Moria SA). A retrospective analysis was performed on 2000 eyes treated in 2008 for low myopia and astigmatism (sphere mechanical microkeratome. All eyes received wavefront-guided LASIK treatments performed with a VISX S4 IR Advanced CustomVue excimer laser (AMO). Refractive predictability, change in mean spherical equivalent refraction, postoperative uncorrected visual acuity (UCVA), and loss of best spectacle-corrected visual acuity (BSCVA) were compared at 1 day, 1 week, 1 month, and 3 months following surgery. The refractive accuracy was the same for both groups. At all time points measured, the percentage of eyes that achieved a postoperative UCVA of 20/20 or better was significantly higher in the femtosecond laser group than in the mechanical keratome group. Also, a higher percentage of eyes in the femtosecond laser group achieved a postoperative UCVA of 20/16 at 3 months. Finally, a lower percentage of eyes in the femtosecond laser group lost two or more lines of BSCVA at 1 week and 1 month postoperative. Creating LASIK flaps with the femtosecond laser resulted in faster visual recovery and better UCVA.

  9. Laser induced rapid decontamination of aromatic compound from porous soil simulant

    Science.gov (United States)

    Zheng, Wenjun; Hou, Sichao; Su, Ming

    2017-08-01

    Soil contamination with organic compounds can lead to the loss of farmable and habitable lands and cause long-term human and animal exposure to toxins. This paper reports a new laser based method for in situ soil decontamination at high efficiency, in which a focused excimer laser is used to remove organic contaminants from soil through burning by generating a local high temperature region. An aromatic compound, 1,1-dichloro-2,2-bis(4-chlorophenyl) ethylene, is used as an organic contaminant, and a porous silica plate is used as a soil simulant. A heat transfer model is created to simulate the interaction between the laser and the organic compound. The lithographic mode of operation allows the accurate quantitation of laser effects. The effects of power, speed, frequency, and energy consumption on the efficiency of decontamination have been examined with high accuracy. The decomposition area increases with the increase in the laser power and the decrease in the scan speed and frequency. Given the high energy conversion yield of the high power laser, this method would be promising for large scale in situ soil decontamination.

  10. Laser-printed/structured thick-film electrodes for Li-ion microbatteries

    Science.gov (United States)

    Kim, Heungsoo; Sutto, Thomas E.; Proell, Johannes; Kohler, Robert; Pfleging, Wilhelm; Piqué, Alberto

    2014-03-01

    Laser induced forward transfer (LIFT) process was used to print thick-film electrodes (LiCoO2 cathode and carbon anode) and solid-state polymer membranes for Li-ion microbatteries. Their electrochemical behaviors were characterized by cyclic voltammograms, capacity measurement and cycling performance. Microbatteries based on these laser-printed thick-film electrodes showed significantly higher discharge capacities than those made by sputter-deposited thin film techniques. This enhanced performance is attributed to the high surface area porous structure of the laser-printed electrodes that allows improved diffusion of the Li-ions across the 100 μm-thick electrodes without a significant internal resistance. In addition, a laser structuring process was used to prepare three-dimensional microstructures on the laserprinted thick-film electrodes to further improve battery performance by increasing the active surface area. These results indicate that the laser processing techniques are a viable approach for developing Li-ion microbatteries in microelectronic devices. This paper will show examples of Li-ion microbatteries fabricated with various polymer separators and structured electrodes using a combination of LIFT and excimer laser structuring processes.

  11. Thermodynamic response of soft biological tissues to pulsed infrared-laser irradiation.

    Science.gov (United States)

    Venugopalan, V; Nishioka, N S; Mikić, B B

    1996-06-01

    The physical mechanisms that achieve tissue removal through the delivery of short pulses of high-intensity infrared laser radiation, in a process known as laser ablation, remain obscure. The thermodynamic response of biological tissue to pulsed infrared laser irradiation was investigated by measuring and analyzing the stress transients generated by Q-sw Er:YSGG (lambda = 2.79 microns) and TEA CO2 (lambda = 10.6 microns) laser irradiation of porcine dermis using thin-film piezoelectric transducers. For radiant exposures that do not produce material removal, the stress transients are consistent with thermal expansion of the tissue samples. The temporal structure of the stress transients generated at the threshold radiant exposure for ablation indicates that the onset of material removal is delayed with respect to irradiation. Once material removal is achieved, the magnitude of the peak compressive stress and its variation with radiant exposure are consistent with a model that considers this process as an explosive event occurring after the laser pulse. This mechanism is different from ArF- and KrF-excimer laser ablation where absorption of ultraviolet radiation by the collagenous tissue matrix leads to tissue decomposition during irradiation and results in material removal via rapid surface vaporization. It appears that under the conditions examined in this study, explosive boiling of tissue water is the process that mediates the ablation event. This study provides evidence that the dynamics and mechanism of tissue ablation processes can be altered by targeting tissue water rather than the tissue structural matrix.

  12. Bulk damage and absorption in fused silica due to high-power laser applications

    Science.gov (United States)

    Nürnberg, F.; Kühn, B.; Langner, A.; Altwein, M.; Schötz, G.; Takke, R.; Thomas, S.; Vydra, J.

    2015-11-01

    Laser fusion projects are heading for IR optics with high broadband transmission, high shock and temperature resistance, long laser durability, and best purity. For this application, fused silica is an excellent choice. The energy density threshold on IR laser optics is mainly influenced by the purity and homogeneity of the fused silica. The absorption behavior regarding the hydroxyl content was studied for various synthetic fused silica grades. The main absorption influenced by OH vibrational excitation leads to different IR attenuations for OH-rich and low-OH fused silica. Industrial laser systems aim for the maximum energy extraction possible. Heraeus Quarzglas developed an Yb-doped fused silica fiber to support this growing market. But the performance of laser welding and cutting systems is fundamentally limited by beam quality and stability of focus. Since absorption in the optical components of optical systems has a detrimental effect on the laser focus shift, the beam energy loss and the resulting heating has to be minimized both in the bulk materials and at the coated surfaces. In collaboration with a laser research institute, an optical finisher and end users, photo thermal absorption measurements on coated samples of different fused silica grades were performed to investigate the influence of basic material properties on the absorption level. High purity, synthetic fused silica is as well the material of choice for optical components designed for DUV applications (wavelength range 160 nm - 260 nm). For higher light intensities, e.g. provided by Excimer lasers, UV photons may generate defect centers that effect the optical properties during usage, resulting in an aging of the optical components (UV radiation damage). Powerful Excimer lasers require optical materials that can withstand photon energy close to the band gap and the high intensity of the short pulse length. The UV transmission loss is restricted to the DUV wavelength range below 300 nm and

  13. Surface and morphological features of laser-irradiated silicon under vacuum, nitrogen and ethanol

    Energy Technology Data Exchange (ETDEWEB)

    Hayat, Asma, E-mail: asmahayat@gcu.edu.pk; Bashir, Shazia; Akram, Mahreen; Mahmood, Khaliq; Iqbal, Muhammad Hassan

    2015-12-01

    Highlights: • Laser irradiation effects on Si surface have been explored. • An Excimer Laser was used as a source. • SEM analysis was performed to explore surface morphology. • Raman spectroscopy analysis was carried out to find crystallographical alterations. - Abstract: Laser-induced surface and structural modification of silicon (Si) has been investigated under three different environments of vacuum, nitrogen (100 Torr) and ethanol. The interaction of 1000 pulses of KrF (λ ≈ 248 nm, τ ≈ 18 ns, repetition rate ≈ 30 Hz) Excimer laser at two different fluences of 2.8 J/cm{sup 2} and 4 J/cm{sup 2} resulted in formation of various kinds of features such as laser induced periodic surface structures (LIPSS), spikes, columns, cones and cracks. Surface morphology has been observed by Scanning Electron Microscope (SEM). Whereas, structural modification of irradiated targets is explored by Raman spectroscopy. SEM analysis exhibits a non-uniform distribution of micro-scale pillars and spikes at the central ablated regime of silicon irradiated at low laser fluence of 2.8 J/cm{sup 2} under vacuum. Whereas cones, pits, cavities and ripples like features are seen at the boundaries. At higher fluence of 4 J/cm{sup 2}, laser induced periodic structures as well as micro-columns are observed. In the case of ablation in nitrogen environment, melting, splashing, self-organized granular structures and cracks along with redeposition are observed at lower fluence. Such types of small scaled structures in nitrogen are attributed to confinement and shielding effects of nitrogen plasma. Whereas, a crater with multiple ablative layers is formed in the case of ablation at higher fluence. Significantly different surface morphology of Si is observed in the case of ablation in ethanol. It reveals the formation of cavities along with small scale pores and less redeposition. These results reveal that the growth of surface and morphological features of irradiated Si are strongly

  14. Laser photocoagulation - eye

    Science.gov (United States)

    Laser coagulation; Laser eye surgery; Photocoagulation; Laser photocoagulation - diabetic eye disease; Laser photocoagulation - diabetic retinopathy; Focal photocoagulation; Scatter (or pan retinal) photocoagulation; Proliferative ...

  15. Imaging laser-induced thermal fields and effects

    Science.gov (United States)

    Verdaasdonck, Rudolf M.

    1995-05-01

    Laser light interaction with biological tissues is a combination of optical, thermal and mechanical effects depending on the energy applied per unit of volume per unit of time. Visualization of the phenomena with a high temporal and spatial resolution, contributes to a better understanding of the mechanism of action, especially when pulsed lasers are involved. For this goal, setups were developed based on Schlieren techniques to image the interaction of pulsed (CO2, Holmium and Excimer) and CW (CO2, Nd:YAG, Cu-vapor) lasers with physiological media and biological tissues. In a 'fast' Schlieren setup, images of shock waves and fast expanding and imploding vapor bubbles were captured using very short light flashes (10 ns-10 microseconds). These recordings suggest that these explosive vapor bubbles seem to be the main dynamism for tissue ablation. In a 'color' Schlieren setup, very small changes in optical density of the media induced by temperature gradients, were color coded. Calibration of the color images to absolute temperatures were performed by using calculated temperature distributions and by thermocouple measurements. Cameras with high speed shutters (0.1-50 ms) enabled the recording of dynamic images of the thermal relaxation and heat diffusion in tissues during variation of pulse length and repetition rate. Despite pulse lengths Schlieren techniques were applied to study the thermal characteristics of laser probes, e.g. for the treatment of Benign Prostatic Hyperplasia (BPH). In combination with thermal modeling an optimal therapy might be predicted. Schlieren techniques, generating high-speed and 'thermal' images, can provide a good understanding of the ablation mechanism and the thermo-dynamics during laser-tissue interaction with continuous wave and pulse lasers.

  16. Time-resolved beam profiler for pulsed lasers

    Science.gov (United States)

    Klick, David I.; Knight, Frederick K.

    1993-04-01

    A high-speed imaging device based on a streak camera has been demonstrated, which provides multiple images from non-repeatable transient events of time scale >= 1 ns. It can be employed for pulsed laser beam diagnostics, measuring laser beam spatial and temporal structure on a single-pulse basis. The system currently has angular resolution of 16 X 16 pixels, with a time resolution of 250 ps. The laser beam width is sized to fill the input optic, and the image is dissected by a square array of optical fibers. At the other end of the fiber optic image converter, the 256 fibers form a line array, which is input to the slit of a streak camera. The streak camera sweeps the input line across the output phosphor screen so that position is directly proportional to time. The resulting 2-D image (fiber position vs. time) at the phosphor is read by an intensified (SIT) vidicon TV tube, and the image is digitized and stored. A computer subsequently decodes the image, unscrambling the linear pixels into an angle-angle image at each time. We are left with a series of snapshots, each one depicting the laser beam spatial profile (intensity cross-section) at succeeding moments in time. The system can currently record several hundred images over a span of 25 to 400 ns. This detector can study lasers of pulse width >= 1 ns and with a visible wavelength (200 - 900 nm). Candidate lasers include doubled Nd:YAG, excimer, ruby, nitrogen, metal vapor, and Ti:Sapphire. The system could also be simply configured as an 8 X 8 element wavefront sensor to record the cross-sectional distribution of phase, as well as amplitude. Finally, suggestions for system improvement are detailed, and the ultimate limitations of the method in terms of spatial and temporal resolution are discussed.

  17. A two-color laser photolysis method for determining reaction rates of short-lived intermediates by product analysis: application to the o-quinodimethane problem.

    Science.gov (United States)

    Ouchi, Akihiko; Li, Zhong; Sakuragi, Masako; Majima, Tetsuro

    2003-01-29

    A time-delayed, two-color pulse laser photolysis technique was used for a kinetic study of short-lived transient species through product analysis, the determination of the rate constant of the cycloaddition of o-quinodimethane (1) and maleic anhydride (2) in room-temperature solutions. o-Quinodimethane (1) was generated from 1,2-bis[(phenylseleno)methyl]benzene (3) by the irradiation of a pulse of a KrF excimer laser (248 nm) in the presence of excess 2, and a successive pulse of a XeCl excimer laser (308 nm) was irradiated to the reaction mixture after varied delay times from 0 to 0.1 s for the decomposition of the remaining 1 to quench the cycloaddition reaction. The rate constant of the cycloaddition of 1 and 2 was 2.1 x 10(5) M(-1) s(-1), which was obtained by the analysis of the delay-time dependence of the product yields.

  18. Evaluation of a novel laser-assisted coronary anastomotic connector - the Trinity Clip - in a porcine off-pump bypass model.

    Science.gov (United States)

    Stecher, David; Bronkers, Glenn; Noest, Jappe O T; Tulleken, Cornelis A F; Hoefer, Imo E; van Herwerden, Lex A; Pasterkamp, Gerard; Buijsrogge, Marc P

    2014-11-24

    To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser catheter laser-punches the opening of the anastomosis. Consequently, owing to the complete nonocclusive anastomosis construction, coronary conditioning (i.e., occluding or shunting) is not necessary, in contrast to the conventional anastomotic technique, hence simplifying the off-pump bypass procedure. Prior to clinical application in coronary artery bypass grafting, the safety and quality of this novel connector will be evaluated in a long-term experimental porcine off-pump coronary artery bypass (OPCAB) study. In this paper, we describe how to evaluate the coronary anastomosis in the porcine OPCAB model using various techniques to assess its quality. Representative results are summarized and visually demonstrated.

  19. Energy coupling and plume dynamics during high power laser heating of metals

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, S. [Univ. of California, Berkeley, CA (United States). Dept. of Mechanical Engineering]|[Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technologies Div.

    1997-05-01

    High power laser heating of metals was studied utilizing experimental and numerical methods with an emphasis on the laser energy coupling with a target and on the dynamics of the laser generated vapor flow. Rigorous theoretical modeling of the heating, melting, and evaporation of metals due to laser radiation with a power density below the plasma shielding threshold was carried out. Experimentally, the probe beam deflection technique was utilized to measure the propagation of a laser induced shock wave. The effects of a cylindrical cavity in a metal surface on the laser energy coupling with a solid were investigated utilizing photothermal deflection measurements. A numerical calculation of target temperature and photothermal deflection was performed to compare with the measured results. Reflection of the heating laser beam inside the cavity was found to increase the photothermal deflection amplitude significantly and to enhance the overall energy coupling between a heating laser beam and a solid. Next, unsteady vaporization of metals due to nanosecond pulsed laser heating with an ambient gas at finite pressure was analyzed with a one dimensional thermal evaporation model for target heating and one dimensional compressible flow equations for inviscid fluid for the vapor flow. Lastly, the propagation of a shock wave during excimer laser heating of aluminum was measured with the probe beam deflection technique. The transit time of the shock wave was measured at the elevation of the probe beam above the target surface; these results were compared with the predicted behavior using ideal blast wave theory. The propagation of a gaseous material plume was also observed from the deflection of the probe beam at later times.

  20. Advantages of dual-laser ablation in the growth of multicomponent thin films

    Science.gov (United States)

    Mukherjee, Devajyoti; Hyde, Robert; Mukherjee, Pritish; Witanachchi, Sarath

    2012-07-01

    We report the use of a dual-laser deposition process to grow stoichiometric films of the piezoelectric material PbZr0.52Ti0.48O3 (PZT) and the thermoelectric material Ba8Ga16Ge30. High volatility of Pb and Ba in these materials leads to non-stoichiometric growth in conventional PLD processes. Dual-laser ablation process preserves the Pb and Ba stoichiometry while significantly reducing the thickness variation and particulate density on the deposited films. This lead to the growth of smooth uniform films with enhanced ferroelectric and electrical properties. The dual-laser ablation combines the pulses of a KrF excimer laser (248 nm wavelength, 30 ns pulse width) and a CO2 laser (10.6 μm wavelength, 250 ns pulse width) where the beams are spatially overlapped on the ablation target and temporally delayed. At an optimum delay that is dependent on the physical properties of the material, CO2 pulse energy is coupled into the plume, generating a high temperature plasma (>25,000K). Laser-target interaction studies have shown the evaporation to be stoichiometric. Emission spectroscopy studies have shown ten-fold increase in emission intensities in dual-laser ablation while time-gated 2D ICCD imaging studies revealed the plume expansion to be stoichiometric over a large cone-angle of the plume under these conditions. Time-of-flight investigations in concert with hydrodynamic modeling provided a clear understanding of the mechanism of dual-laser ablation. Furthermore, plasma generated in the process is highly ionized (>75%) leading to films with high density and crystallinity. This paper will show the enhancement in properties attainable by the dual-laser ablation process in comparison to the single laser ablation.

  1. Osseointegration of KrF laser hydroxylapatite films on Ti6A14V alloy by mini-pigs: loaded osseointegration of dental implants

    Science.gov (United States)

    Dostalova, Tatjana; Jelinek, Miroslav; Himmlova, Lucia; Grivas, Christos

    1999-05-01

    Aim of study was to evaluate osseointegration of the KrF laser hydroxyapatite coated titanium alloy Ti6Al4V dental implants. For deposition KrF excimer laser in stainless- steel deposition chamber was used. Thickness of HA films were round 1 μm . Mini-pigs were used in this investigation. Implants were placed vertically into the lower jaw. After 14 weeks unloaded osseointegration the metal ceramic crowns were inserted. the experimental animals were sacrificed (1 year post insertion). The vertical position of implants was controlled with a radiograph. Microscopical sections were cut and ground. Sections were viewed using microscope with CCD camera. 1 year osseointegration in lower jaw confirmed by all implants presence of newly formed bone around the all implants. Laser-deposited coating the layer of fibrous connective tissue was seen only seldom. In the control group (titamium implant without cover) the fibrous connective tissue was seen between implant and newly formed bone.

  2. Biocavity Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Gourley, P.L.; Gourley, M.F.

    2000-10-05

    Laser technology has advanced dramatically and is an integral part of today's healthcare delivery system. Lasers are used in the laboratory analysis of human blood samples and serve as surgical tools that kill, burn or cut tissue. Recent semiconductor microtechnology has reduced the size o f a laser to the size of a biological cell or even a virus particle. By integrating these ultra small lasers with biological systems, it is possible to create micro-electrical mechanical systems that may revolutionize health care delivery.

  3. Laser Materials and Laser Spectroscopy - A Satellite Meeting of IQEC '88

    Science.gov (United States)

    Wang, Zhijiang; Zhang, Zhiming

    1989-03-01

    Highly Excited Vibrational State * Investigation of the Stark Effect in Xenon Autoionizing Rydberg Series with the Use of Coherent Tunable XUV Radiation * Laser Spectroscopy of Autoionising 5 dnf J = 4.5 Rydberg Series of Ba I * Resonance Photoionization Spectroscopy of Atoms: Autoionization and Highly Excited States of Kr and U * Stark Spectra of Strontium and Calcium Atoms * Observation of Bidirectional Stimulated Radiation at 330 nm, 364 nm and 718 nm with 660 nm Laser Pumping in Sodium Vapour * Study of Molecular Rydberg States and their Discriminations in Na2 * The Measurement of the High Excited Spectra of Samarium by using Stepwise Laser Excitation Method * Product Analysis in the Reaction of the Two-photon Excited Xe(5p56p) States with Freons * Photoionization Spectra of Ca and Sr Atoms above the Classical Field-ionization Threshold * Effect of Medium Background on the Hydrogen Spectrum * Photoemission and Photoelectron Spectra from Autoionizing Atoms in Strong Laser Field * Natural Radiative Lifetime Measurements of High-lying States of Samarium * Two-step Laser Excitation of nf Rydberg States in Neutral Al and Observation of Stark Effect * Measurements of Excited Spectra of the Refractory Metal Elements using Discharge Synchronized with the Laser Pulse * Multiphoton Ionization of Atomic Lead at 1.06μ * Kinetic Processes in the Electron-beam pumped KrF Laser * Laser-induced Fluorescence of Zn2 Excimer * Calculation of Transition Intensity in Heteronuclear Dimer NaK: Comparison with Experiment * Laser-induced Fluorescence of CCl2 Carbene * Study of Multiphoton Ionization Spectrum of Benzene and Two-photon Absorption Cross Section * Dicke Narrowing of N2O Linewidth Perturbed by N2 at 10 μm Band * Polyatomic Molecular Ions Studied by Laser Photodissociation Spectroscopy * Transverse-optically Pumped Ultraviolet S2 Laser * Multiphoton Ionization of Propanal by High Power Laser * UV MPI Mass Spectroscopy and Dynamics of Photodissociation of SO2 * Multiphoton

  4. Monochromatic excimer light versus combination of topical steroid with vitamin D3 analogue in the treatment of nonsegmental vitiligo: a randomized blinded comparative study.

    Science.gov (United States)

    Abdel Latif, Azmy Ahmed; Ibrahim, Shady Mahmoud Attia

    2015-01-01

    Vitiligo is a difficult disease to treat, socially stigmatizing its patients. Monochromatic excimer light (MEL) was developed for use in dermatology and adapted for the treatment of vitiligo. Comparing the efficacy of MEL versus topical combination therapy of vitamin D3 analogue and steroid in the treatment of nonsegmental vitiligo. Forty-four patients with localized and stable nonsegmental vitiligo participated in the present study. In each patient, two lesions were selected and divided randomly into two groups, group A was treated with daily topical combination of calcipotriol and betamethasone and group B was treated with biweekly sessions of MEL for 3 months. Efficacy based on repigmentation percentages were blindly evaluated by two independent physicians and patient's satisfaction. There was significant improvement in both treatment modalities at the end of the study, but without significant differences in both groups. There was a significant difference between both groups regarding the onset of repigmentation (p-value vitiligo. © 2015 Wiley Periodicals, Inc.

  5. High power lasers & systems

    OpenAIRE

    Chatwin, Chris; Young, Rupert; Birch, Philip

    2015-01-01

    Some laser history;\\ud Airborne Laser Testbed & Chemical Oxygen Iodine Laser (COIL);\\ud Laser modes and beam propagation;\\ud Fibre lasers and applications;\\ud US Navy Laser system – NRL 33kW fibre laser;\\ud Lockheed Martin 30kW fibre laser;\\ud Conclusions

  6. Generation of metallic arc spectrum of pumping discharge of XeCl laser; XeCl ekishima laser reiki hoden ni okeru arc iko to kinzoku supekutoru no hassei

    Energy Technology Data Exchange (ETDEWEB)

    Koike, H.; Yukimura, K. [Doshisha University, Kyoto (Japan)

    1997-12-20

    An arc generation of a long-pulse spiker-sustainer excimer laser with about 250ns of pulse width , is discussed by using time-varying spectroscopic method. First arcing occurs during a main discharge for laser excitation and shows XeII spectrum, while a glow-like discharge represents only XeI spectrum, the metallic spectrum such as Nil caused by vaporization of electrode material begins to appear just after the termination of the main discharge. Second arcing occurs after about 2{mu}s, which brings strong intensity of Nil spectrum. It means that the reignition arc might be produced in a metallic vapor that appears during the main discharge. Accordingly, it is concluded that the reignition arc is inherently metallic, which is different from the main arc with rare gas plasma. 9 refs., 9 figs.

  7. Evaluation of the Safety and Efficacy of Excimer Laser Keratorefractive Surgery in U.S. Army Soldiers using the latest Battlefield Technologies

    Science.gov (United States)

    2007-04-01

    na.amedd.army.mil). Copyright 2005 by Lippincott Williams & Wilkins 870 Cornea Volume 24, Number 7, October 2005 rust-brown coloration . The line was...Keratokonus und eigenartige Pigmentbildung in der Kornea. München Med Wochenschr. 1906;53:625–626. 2. Hudson AC. A note on certain peculiar pigmentary ...outlined area including the number of pixels (Fig. 2). If the area has distinct borders and is uniform in color , the magic wand tool can be used to

  8. Initial performance metrics of a new custom-designed ArF excimer LA-ICPMS system coupled to a two-volume laser-ablation cell

    OpenAIRE

    Muller, Wolfgang; Shelley, Michael; Miller, Pascal; Broude, Sergey

    2009-01-01

    We measure the performance improvement that force feedback can provide in a virtual environment, through three experiments with, and without the assistance of haptic guidance. Performance measurements were undertaken with haptic, visual and auditory feedback alternatives. The first task investigated the use of haptic guidance mimicking reality, in the form of a simulated touchable surface of an object. The second investigated haptic guidance which waxed and waned as the user violated program ...

  9. Chip design for thin-film deep ultraviolet LEDs fabricated by laser lift-off of the sapphire substrate

    Science.gov (United States)

    Cho, H. K.; Krüger, O.; Külberg, A.; Rass, J.; Zeimer, U.; Kolbe, T.; Knauer, A.; Einfeldt, S.; Weyers, M.; Kneissl, M.

    2017-12-01

    We report on a chip design which allows the laser lift-off (LLO) of the sapphire substrate sustaining the epitaxial film of flip-chip mounted deep ultraviolet light emitting diodes. A nanosecond pulsed excimer laser with a wavelength of 248 nm was used for the LLO. A mechanically stable chip design was found to be the key to prevent crack formation in the epitaxial layers and material chipping during the LLO process. Stabilization was achieved by introducing a Ti/Au leveling layer that mechanically supports the fragile epitaxial film. The electrical and optical characterization of devices before and after the LLO process shows that the device performance did not degrade by the LLO.

  10. Preparation of TiO sub 2 nanoparticles by pulsed laser ablation: Ambient pressure dependence of crystallization

    CERN Document Server

    Matsubara, M; Yamaki, T; Itoh, H; Abe, H

    2003-01-01

    Pulsed laser ablation (PLA) with a KrF excimer laser was used to prepare fine particles of titanium dioxide (TiO sub 2). The ablation in an atmosphere of Ar and O sub 2 (5:5) at total pressures of >= 1 Torr led to the formation of TiO sub 2 nanoparticles composed of anatase and rutile structures without any suboxides. The weight fraction of the rutile/anatase crystalline phases was dependent on the pressure of the Ar/O sub 2 gas. The TiO sub 2 nanoparticles had a spherical shape and their size, ranging from 10 and 14 nm, also appeared to be dependent on the ambient pressure. (author)

  11. Thin films of polymer mimics of cross-linking mussel adhesive proteins deposited by matrix assisted pulsed laser evaporation

    Science.gov (United States)

    Cristescu, R.; Mihailescu, I. N.; Stamatin, I.; Doraiswamy, A.; Narayan, R. J.; Westwood, G.; Wilker, J. J.; Stafslien, S.; Chisholm, B.; Chrisey, D. B.

    2009-03-01

    Mussels secrete specialized adhesives known as mussel adhesive proteins, which allow attachment of the organisms to underwater marine environments. Obtaining large quantities of naturally derived mussel adhesive proteins adhesives has proven to date rather problematic, thus, synthetic analogs of mussel adhesive proteins have recently been developed. We report deposition of 1:100 and 1:1000 poly[(3,4-dihydroxystyrene)-co-styrene)] mussel adhesive protein analogs by matrix assisted pulsed laser evaporation (MAPLE) using an ArF* excimer laser source. The deposited films have been evaluated for their antifouling behavior. The MAPLE-deposited synthetic mussel adhesive protein analog thin films are homogenous and adhesive, making the use of these materials in thin film form a viable option.

  12. Survey of Laser Markets Relevant to Inertial Fusion Energy Drivers, information for National Research Council

    Energy Technology Data Exchange (ETDEWEB)

    Bayramian, A J; Deri, R J; Erlandson, A C

    2011-02-24

    Development of a new technology for commercial application can be significantly accelerated by leveraging related technologies used in other markets. Synergies across multiple application domains attract research and development (R and D) talent - widening the innovation pipeline - and increases the market demand in common components and subsystems to provide performance improvements and cost reductions. For these reasons, driver development plans for inertial fusion energy (IFE) should consider the non-fusion technology base that can be lveraged for application to IFE. At this time, two laser driver technologies are being proposed for IFE: solid-state lasers (SSLs) and KrF gas (excimer) lasers. This document provides a brief survey of organizations actively engaged in these technologies. This is intended to facilitate comparison of the opportunities for leveraging the larger technical community for IFE laser driver development. They have included tables that summarize the commercial organizations selling solid-state and KrF lasers, and a brief summary of organizations actively engaged in R and D on these technologies.

  13. The variation in surface morphology and hardness of human deciduous teeth samples after laser irradiation

    Science.gov (United States)

    Khalid, Arooj; Bashir, Shazia; Akram, Mahreen; Salman Ahmed, Qazi

    2017-11-01

    The variation in surface morphology and hardness of human deciduous teeth samples has been investigated after laser irradiation at different wavelengths and energies. Nd:YAG was employed as a source of irradiation for IR (1064 nm) and visible (532 nm) radiation, whereas an excimer laser was used as the source of UV (248 nm) radiation. Scanning electron microscope (SEM) analysis was carried out to reveal the surface morphological evolution of teeth samples. Vickers microhardness tester was employed to investigate the modifications in the hardness of the laser-treated samples. It is observed from SEM analysis that IR wavelength is responsible for ablation of collagen matrix and intertubular dentine. For visible radiation, the ablation of collagen along with hydroxypatite is observed. With UV radiation, the ablation of peritubular dentine is dominant and is responsible for the sealing of tubules. The decrease in hardness at lower energy for both wavelengths is due to the evaporation of carbon content. With increasing energy, evaporation of water along with carbon content, and resolidification and re-organization of inorganic content causes the increase in hardness of the treated dentine. SEM as well as microhardness analyses reveal that laser wavelengths and energy of laser radiation significantly influence the surface morphology and hardness of samples.

  14. The preparation of iron complex oxide nanoparticles by pulsed-laser ablation

    Science.gov (United States)

    Sasaki, T.; Terauchi, S.; Koshizaki, N.; Umehara, H.

    1998-05-01

    Nanoparticles of a calcium-iron complex oxide were prepared by pulsed laser ablation on silicon wafer substrates placed at off-axial positions against a target. An ArF excimer laser was used to irradiate a CaFe 2O 4 target in atmospheres of Ar and O 2 at room temperature. The effects of ambient pressure and laser pulse energy on size and composition of nanoparticles were investigated using atomic force microscopy and X-ray photoelectron spectroscopy. The nanoparticles obtained were almost spherical and 2 to 26 nm in diameter. The size distributions of the nanoparticles were very narrow and agreed with the log-normal distribution function. The nanoparticle size increased with ambient pressure and pulse energy. The Ca/Fe atomic ratios in the nanoparticles, however, decreased with increasing ambient pressure and were independent of pulse energy. By this technique, the size and composition of nanoparticles can be easily controlled by laser fluence and pressure during the laser ablation.

  15. Ripple polystyrene nano-pattern induced by KrF laser

    Directory of Open Access Journals (Sweden)

    P. Slepicka

    2014-07-01

    Full Text Available The study of excimer laser treatment of polystyrene surface was performed. The influence of laser fluence and number of laser pulses on surface chemistry and morphology was determined. The surface morphology and roughness were studied with atomic force microscopy. Surface wettability and aging studies were characterized by the water contact angle measurements. Surface oxygen concentration and chemistry were evaluated from X-ray photoelectron spectroscopy and zeta potential measurements. The optimal polystyrene treatment parameters for the most regular pattern were determined. The foils with optimal ripple pattern were subsequently sputtered with gold nano-layers of 100 nm thickness. It was found that the surface roughness of PS strongly depends on number of pulses. The aging study revealed that the higher contact angle achieve the samples treated with higher laser fluence. The deposition of gold nano-layer increases the surface roughness of nano-patterned surface. It was proved that the oxygen concentration is significantly influenced by the KrF laser exposure.

  16. Wafer scale integration of reduced graphene oxide by novel laser processing at room temperature in air

    Science.gov (United States)

    Bhaumik, Anagh; Narayan, Jagdish

    2016-09-01

    Physical properties of reduced graphene oxide (rGO) strongly depend on the ratio of sp2 to sp3 hybridized carbon atoms, the presence of different functional groups, and the characteristics of the substrates. This research for the very first time illustrates successful wafer scale integration of 2D rGO with Cu/TiN/Si, employing pulsed laser deposition followed by laser annealing of carbon-doped copper layers using nanosecond excimer lasers. The XRD, SEM, and Raman spectroscopy measurements indicate the presence of large area rGO onto Si having Raman active vibrational modes: D, G, and 2D. A high resolution SEM depicts the morphology and formation of rGO from zone-refined carbon formed after nanosecond laser annealing. Temperature-dependent resistance data of rGO thin films follow the Efros-Shklovskii variable range hopping (VRH) model in the low-temperature region and Arrhenius conduction in the high-temperature regime. The photoluminescence spectra also reveal a less intense and broader blue fluorescence spectra, indicating the presence of miniature sized sp2 domains in the near vicinity of π* electronic states which favor the VRH transport phenomena. This wafer scale integration of rGO with Si employing a laser annealing technique will be useful for multifunctional integrated electronic devices and will open a new frontier for further extensive research in these functionalized 2D materials.

  17. Hyperspectral and gated ICCD imagery for laser irradiated carbon materials

    Science.gov (United States)

    Roberts, Charles D.; Acosta, Roberto A.; Marciniak, Michael A.; Perram, Glen P.

    2013-02-01

    New optical diagnostics for studying laser ablation and induced combustion for carbon materials are key to monitoring the evolving, spatial distribution of the gas plume. We are developing high speed imaging FTIR and gated ICCD imagery for materials processing, manufacture process control, and high energy laser applications. The results from two projects will be discussed. First, an imaging Fourier Transform Spectrometer with a 320 x 256 InSb focal plane array frames at 1.9 kHz with a spatial resolution of 1 mm and spectral resolution of up to 0.25 cm-1. Gas phase plumes above the surface of laser-irradiated black plexiglass, fiberglass and painted thin metals have been spectrally resolved. Molecular emission from CO, CO2, H2O, and hydrocarbons is readily identified. A line-by-line radiative transfer model is used to derive movies for specie concentrations and temperatures. Second, excimer laser pulsed ablation of bulk graphite into low-pressure (0.05 - 1 Torr) argon generates highly ionized, high speed (M>40) plumes. A gated, intensified CCD camera with band pass filtering has been used to generate plume imagery with temporal resolution of 10ns. The Sedov-Taylor shock model characterizes the propagation of the shock front if the dimensionality of the plume is allowed to deviate from ideal spherical expansion. A drag model is more appropriate when the plume approaches extinction (~10 μs) and extends the characterization into the far field. Conversion of laser pulse energy to the shock is efficient.

  18. Lasers technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    The Lasers Technology Program of IPEN is strongly committed to the study of Laser Applications on several areas: Nuclear, Medicine and Dentistry, Industry, Environment and Advanced research, aiming not only research but diffusion and innovation in association with Brazilian universities and commercial partners.

  19. Laser device

    Science.gov (United States)

    Scott, Jill R.; Tremblay, Paul L.

    2008-08-19

    A laser device includes a virtual source configured to aim laser energy that originates from a true source. The virtual source has a vertical rotational axis during vertical motion of the virtual source and the vertical axis passes through an exit point from which the laser energy emanates independent of virtual source position. The emanating laser energy is collinear with an orientation line. The laser device includes a virtual source manipulation mechanism that positions the virtual source. The manipulation mechanism has a center of lateral pivot approximately coincident with a lateral index and a center of vertical pivot approximately coincident with a vertical index. The vertical index and lateral index intersect at an index origin. The virtual source and manipulation mechanism auto align the orientation line through the index origin during virtual source motion.

  20. Laser instrument

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera, R.J.; Eagar, T.W.

    1986-04-08

    An instrument is described for intercepting a carbon dioxide incident laser beam after it has energized a desired surgical target site but before it energizes material adjacent to the surgical target site. The instrument consists of: a substrate means for transmitting energy received from a laser beam away from a surgical target site, the substrate means having a high thermal conductivity and an exterior surface; a coating means for absorbing laser energy at the wavelength of a carbon dioxide laser, the coating means covering substantially the entirety of the exterior surface of the substrate means and having a high absorptivity for energy at the wavelength of the incident laser beam; and, the coating means having thickness which is large enough to provide high absorptivity but small enough to permit absorbed energy to be readily transferred to the high conductivity substrate means, and the thickness of the coating means being not greater than 0.001 inch.

  1. Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creation.

    Science.gov (United States)

    Muñoz, Gonzalo; Albarrán-Diego, César; Ferrer-Blasco, Teresa; García-Lázaro, Santiago; Cerviño-Expósito, Alejandro

    2010-11-01

    To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Private practice refractive surgery center, Valencia, Spain. Comparative case series. Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were computed from the anterior corneal surface measured with topography for 4.0 mm and 6.0 mm pupil diameters before and 48 months after surgery. The study evaluated 50 patients (98 eyes). The root mean square of HOAs increased postoperatively by a factor of approximately 1.9 in both groups and with both pupil diameters. There were no statistically significant differences between the 2 groups in the increase in anterior corneal aberrations, mean postoperative visual acuity, or residual refraction. All visual and optical performance metrics remained stable throughout the 4-year follow-up. There were no complications with flap creation and no postoperative complications. The increase in anterior corneal aberrations after myopic LASIK was similar after mechanical microkeratome and femtosecond laser flap creation. Visual acuity, refraction, and the optical quality of the cornea after LASIK remained stable through 4 years postoperatively in both groups. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Measurement of corneal curvature change after mechanical laser in situ keratomileusis flap creation and femtosecond laser flap creation.

    Science.gov (United States)

    Ortiz, Dolores; Alió, Jorge L; Piñero, David

    2008-02-01

    To compare the change in corneal curvature from the predicted surgical radius (sculpted in the corneal stroma) and the measured postoperative radius of the first surface of the cornea after laser in situ keratomileusis (LASIK) for myopia correction using 2 methods of flap creation: mechanical microkeratome and femtosecond laser. Vissum-Instituto Oftalmológico de Alicante, Alicante, Spain. This retrospective consecutive nonrandomized comparative interventional case series included 85 eyes with myopia or myopic astigmatism treated using the Esiris excimer laser (Schwind). Patients were divided into 2 groups. One group had LASIK with an M2 microkeratome (Moria) (mechanical LASIK group) and the other, with a femtosecond laser (IntraLase FS, IntraLase Corp.) (femtosecond LASIK group). The relationship between the postsurgical corneal radius and the predicted sculpted radius as well as the mean value of the percentage change in the curvature radius were analyzed to obtain the effect on the refractive defect in each group. There were 44 eyes in the mechanical LASIK group and 41 eyes in the femtosecond LASIK group. A high correlation was found between the final corneal radius and the predicted sculpted radius in both groups (r(2) = 0.85). The mean percentage change in the curvature radius was -3.6% in the mechanical LASIK group and -1.6% in the femtosecond LASIK group (Prefractive change was 1.2 diopters (D) and 0.8 D, respectively. The refractive change in corneal curvature, which related to the biomechanical response of the corneal surface after the flap cut and repositioning, was lower after femtosecond laser LASIK than after LASIK performed using a mechanical microkeratome. Estimations of refractive change induced by this response should be taken into account in surgery design.

  3. High throughput laser processing

    Energy Technology Data Exchange (ETDEWEB)

    Harley, Gabriel; Pass, Thomas; Cousins, Peter John; Viatella, John

    2016-12-27

    A solar cell is formed using a solar cell ablation system. The ablation system includes a single laser source and several laser scanners. The laser scanners include a master laser scanner, with the rest of the laser scanners being slaved to the master laser scanner. A laser beam from the laser source is split into several laser beams, with the laser beams being scanned onto corresponding wafers using the laser scanners in accordance with one or more patterns. The laser beams may be scanned on the wafers using the same or different power levels of the laser source.

  4. Selective ablation of photovoltaic materials with UV laser sources for monolithic interconnection of devices based on a-Si:H

    Energy Technology Data Exchange (ETDEWEB)

    Molpeceres, C. [Centro Laser UPM, Univ. Politecnica de Madrid, Crta. de Valencia Km 7.3, 28031 Madrid (Spain)], E-mail: carlos.molpeceres@upm.es; Lauzurica, S.; Garcia-Ballesteros, J.J.; Morales, M.; Guadano, G.; Ocana, J.L. [Centro Laser UPM, Univ. Politecnica de Madrid, Crta. de Valencia Km 7.3, 28031 Madrid (Spain); Fernandez, S.; Gandia, J.J. [Dept. de Energias Renovables, Energia Solar Fotovoltaica, CIEMAT, Avda, Complutense 22, 28040 Madrid (Spain); Villar, F.; Nos, O.; Bertomeu, J. [CeRMAE Dept. Fisica Aplicada i Optica, Universitat de Barcelona, Av. Diagonal 647, 08028 Barcelona (Spain)

    2009-03-15

    Lasers are essential tools for cell isolation and monolithic interconnection in thin-film-silicon photovoltaic technologies. Laser ablation of transparent conductive oxides (TCOs), amorphous silicon structures and back contact removal are standard processes in industry for monolithic device interconnection. However, material ablation with minimum debris and small heat affected zone is one of the main difficulty is to achieve, to reduce costs and to improve device efficiency. In this paper we present recent results in laser ablation of photovoltaic materials using excimer and UV wavelengths of diode-pumped solid-state (DPSS) laser sources. We discuss results concerning UV ablation of different TCO and thin-film silicon (a-Si:H and nc-Si:H), focussing our study on ablation threshold measurements and process-quality assessment using advanced optical microscopy techniques. In that way we show the advantages of using UV wavelengths for minimizing the characteristic material thermal affection of laser irradiation in the ns regime at higher wavelengths. Additionally we include preliminary results of selective ablation of film on film structures irradiating from the film side (direct writing configuration) including the problem of selective ablation of ZnO films on a-Si:H layers. In that way we demonstrate the potential use of UV wavelengths of fully commercial laser sources as an alternative to standard backscribing process in device fabrication.

  5. Effect of laser radiation on multi-wall carbon nanotubes: study of shell structure and immobilization process

    Energy Technology Data Exchange (ETDEWEB)

    Gyoergy, Enikoe, E-mail: egyorgy@icmab.es; Perez del Pino, Angel [Instituto de Ciencia de Materiales de Barcelona, Consejo Superior de Investigaciones Cientificas (ICMAB-CSIC) (Spain); Roqueta, Jaume; Ballesteros, Belen [Centro de Investigaciones en Nanociencia y Nanotecnologia, Consejo Superior de Investigaciones Cientificas (CIN2-CSIC) (Spain); Cabana, Laura; Tobias, Gerard [Instituto de Ciencia de Materiales de Barcelona, Consejo Superior de Investigaciones Cientificas (ICMAB-CSIC) (Spain)

    2013-08-15

    Multi-wall carbon nanotubes (MWCNTs) with diameters between 10 and 15 nm were transferred and immobilized onto SiO{sub 2} glass substrates by ultraviolet matrix assisted pulsed laser evaporation (UV-MAPLE). Toluene was chosen as solvent material for the preparation of the composite MAPLE targets. An UV KrF* ({lambda} = 248 nm, {tau}{sub FWHM} {approx_equal} 25 ns, {nu} = 10 Hz) excimer laser source was used for the irradiation experiments. The effects of incident laser fluence on the structure of the laser transferred MWCNTs was investigated by high resolution transmission electron microscopy and Raman spectroscopy. The surface morphology of the laser processed MWCNTs was investigated by field emission scanning electron microscopy and atomic force microscopy in acoustic (dynamic) configuration. Network-like structures constituted by individual nanotubes and nanotube bundles were created onto solid substrates. Changes in the nanotubes' shell structure can be induced through the tuning of the laser fluence value incident onto the composite MAPLE targets.

  6. Laser spectroscopy

    CERN Document Server

    Demtröder, Wolfgang

    2008-01-01

    Keeping abreast of the latest techniques and applications, this new edition of the standard reference and graduate text on laser spectroscopy has been completely revised and expanded. While the general concept is unchanged, the new edition features a broad array of new material, e.g., frequency doubling in external cavities, reliable cw-parametric oscillators, tunable narrow-band UV sources, more sensitive detection techniques, tunable femtosecond and sub-femtosecond lasers (X-ray region and the attosecond range), control of atomic and molecular excitations, frequency combs able to synchronize independent femtosecond lasers, coherent matter waves, and still more applications in chemical analysis, medical diagnostics, and engineering.

  7. Fatigue Testing of Materials by UV Pulsed Laser Irradiation

    CERN Document Server

    Calatroni, S; Taborelli, M

    2004-01-01

    The energy dissipated by the RF currents in the cavities of pulsed high-power linacs induces cycles of the surface temperature. In the case of the CLIC main linac the expected amplitude of the thermal cycles is above fifty degrees, for a total number of pulses reaching 1011. The differential thermal expansion due to the temperature gradient in the material creates a cyclic stress that can result in surface break-up by fatigue. The materials for cavity fabrication must therefore be selected in order to withstand such constraints whilst maintaining an acceptable surface state. The fatigue behaviour of Cu and CuZr alloy has been tested by inducing larger surface peak temperatures, thus reducing the number of cycles to failure, irradiating the surface with 40 ns pulses of UV light (308 nm) from an excimer laser. Surface break-up is observed after different number of laser shots as a function of the peak temperature. CuZr appears to withstand a much larger number of cycles than Cu, for equal peak temperature. The ...

  8. Laser-assisted immobilization of colloid silver nanoparticles on polyethyleneterephthalate

    Science.gov (United States)

    Siegel, Jakub; Lyutakov, Oleksiy; Polívková, Markéta; Staszek, Marek; Hubáček, Tomáš; Švorčík, Václav

    2017-10-01

    Immobilization of nanoobjects on the surface of underlying material belongs to current issues of material science. Such altered materials exhibits completely exceptional properties exploitable in a broad spectrum of industrially important applications ranging from catalysts up to health-care industry. Here we present unique approach for immobilization of electrochemically synthesized silver nanoparticles on polyethyleneterephthalate (PET) foil whose essence lies in physical incorporation of particles into thin polymer surface layer induced by polarized excimer laser light. Changes in chemical composition and surface structure of polymer after particle immobilization were recorded by wide range of analytical techniques such as ARXPS, EDX, RBS, AAS, Raman, ICP-MS, DLS, UV-vis, SEM, TEM, and AFM. Thorough analysis of both nanoparticles entering the immobilization step as well as modified PET surface allowed revealing the mechanism of immobilization process itself. Silver nanoparticles were physically embedded into a thin surface layer of polymer reaching several nanometers beneath the surface rather than chemically bonded to PET macromolecules. Laser-implanted nanoparticles open up new possibilities especially in the development of the next generation cell-conform antimicrobial coatings of polymeric materials, namely due to the considerable immobilization strength which is strong enough to prevent particle release into the surrounding environment.

  9. LASER PHYSICS: Optical pumping of xenon gas lasers

    Science.gov (United States)

    Zuev, V. S.; Kanaev, A. V.; Mikheev, L. D.

    1987-07-01

    The absolute quantum efficiency of the luminescence emitted by gaseous xenon in the vacuum ultraviolet range was determined as a function of the concentration of the gas and the luminescence wavelength. The main channel for decay of Xe2* excimers after excitation right up to the ionization limit was radiative. The possibility of using xenon-based mixtures as active media was analyzed.

  10. Comparison of DLK incidence after laser in situ keratomileusis associated with two femtosecond lasers: Femto LDV and IntraLase FS60

    Directory of Open Access Journals (Sweden)

    Tomita M

    2013-07-01

    Full Text Available Minoru Tomita,1–3 Yuko Sotoyama,1 Satoshi Yukawa,1 Tadayuki Nakamura1 1Shinagawa LASIK Center, Chiyoda-ku, Tokyo, Japan; 2Department of Ophthalmology, Wenzhou Medical College, Wenzhou, People’s Republic of China; 3Eye Can Cataract Surgery Center, Manila, Philippines Purpose: To compare the incidence of diffuse lamellar keratitis (DLK after laser in situ keratomileusis (LASIK with flap creation using the Femto LDV and IntraLase™ FS60 femtosecond lasers. Methods: A total of 818 consecutive myopic eyes had LASIK performed using either Femto LDV or IntraLase FS60 for flap creation. The same excimer laser, the Allegretto Wave® Eye-Q Laser, was used for correcting refractive errors for all patients. In the preoperative examination, uncorrected distance visual acuity, corrected distance visual acuity, and manifest refraction spherical equivalent were measured. At the postop examination, the same examinations were performed along with a slit-lamp biomicroscopic examination, and patients with DLK were classified into stages. For the statistical analysis of the DLK occurrence rate and the visual and refractive outcomes, the Mann-Whitney’s U-test was used. Results: In the Femto LDV group with 514 eyes, 42 (8.17% had DLK. In the IntraLase FS60 group with 304 eyes, 114 (37.5% had DLK. There was a statistically significant difference in the DLK incidence rate between these groups (P < 0.0001. Both groups had excellent visual and refractive outcomes. Although low levels of DLK were observed for both groups, they did not affect visual acuity. Conclusion: While there were significantly fewer incidences of low level DLK when using Femto LDV, neither femtosecond laser induced high levels of DLK, and any postoperative DLK cleared up within 1 week. Therefore, both lasers provide excellent results, with no clinical differences, and both excel at flap creation for LASIK. Keywords: LASIK, Ziemer, Femto LDV, DLK, IntraLase FS60, femtosecond laser

  11. Combined intrastromal astigmatic keratotomy and laser in situ keratomileusis flap followed by photoablation to correct post-penetrating keratoplasty ametropia and high astigmatism: One-year follow-up.

    Science.gov (United States)

    Shalash, Riad B; Elshazly, Malak I; Salama, Marwa M

    2015-10-01

    To evaluate a new technique combining intrastromal astigmatic keratotomy (AK) with a laser in situ keratomileusis (LASIK) flap followed by excimer laser photoablation to correct post-penetrating keratoplasty (PKP) high astigmatism and ametropia. Kasr El Aini Hospital, Cairo University, Cairo, Egypt. Prospective interventional uncontrolled case series. Patients with post-PKP high astigmatism and ametropia had paired intrastromal AK with LASIK flap using the M2 microkeratome followed 2 to 3 months later by excimer laser photoablation. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), mean refractive spherical equivalent (SE), and mean cylinder after each step and at the 1-year follow-up. The study comprised 20 eyes (20 patients). All parameters were significantly improved in all patients by the last follow-up visit. The mean UDVA improved from 1.07 logMAR ± 0.2 (SD) preoperatively to 0.23 ± 0.18 logMAR (P astigmatism and ametropia following PKP; however, epithelial ingrowth requiring intervention is a complication to be considered. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Optical properties of highly n-doped germanium obtained by in situ doping and laser annealing

    Science.gov (United States)

    Frigerio, J.; Ballabio, A.; Gallacher, K.; Gilberti, V.; Baldassarre, L.; Millar, R.; Milazzo, R.; Maiolo, L.; Minotti, A.; Bottegoni, F.; Biagioni, P.; Paul, D.; Ortolani, M.; Pecora, A.; Napolitani, E.; Isella, G.

    2017-11-01

    High n-type doping in germanium is essential for many electronic and optoelectronic applications especially for high performance Ohmic contacts, lasing and mid-infrared plasmonics. We report on the combination of in situ doping and excimer laser annealing to improve the activation of phosphorous in germanium. An activated n-doping concentration of 8.8  ×  1019 cm‑3 has been achieved starting from an incorporated phosphorous concentration of 1.1  ×  1020 cm‑3. Infrared reflectivity data fitted with a multi-layer Drude model indicate good uniformity over a 350 nm thick layer. Photoluminescence demonstrates clear bandgap narrowing and an increased ratio of direct to indirect bandgap emission confirming the high doping densities achieved.

  13. A method of atmospheric density measurements during space shuttle entry using ultraviolet-laser Rayleigh scattering

    Science.gov (United States)

    Mckenzie, Robert L.

    1988-01-01

    An analytical study and its experimental verification are described which show the performance capabilities and the hardware requirements of a method for measuring atmospheric density along the Space Shuttle flightpath during entry. Using onboard instrumentation, the technique relies on Rayleigh scattering of light from a pulsed ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing density measurements with an uncertainty of less than 1 percent and with a spatial resolution along the flightpath of 1 km, over an altitude range from 50 to 90 km. Experimental verification of the signal linearity and the expected signal-to-noise ratios is demonstrated in a simulation facility at conditions that duplicate the signal levels of the flight environment.

  14. Laser endoscopy.

    Science.gov (United States)

    McElvein, R B

    1981-11-01

    A carbon dioxide laser operating in the invisible infrared range (10.6 mu) generates a beam of energy that is almost completely absorbed by biological tissue with release of intense heat and rapid destruction. A laser attached to a rigid bronchoscope has been used in 18 patients ranging in age from 21 to 62 years to treat a variety of causes of airway obstruction. These include tracheal stenosis and granulation tissue (6 patients), adenoma (1), web (2), and carcinoma (9). The results were good in 15 and poor in 3 patients. However, all patients had an improved airway after laser treatment with the best results occurring in patients with benign, inflammatory disease. The advantages of the laser are a lack of bleeding, minimal edema after treatment, and minimal scar formation. The disadvantages are the expense of the machine, and the need for general anesthesia and direct visualization of the lesion.

  15. Laser Refractography

    CERN Document Server

    Rinkevichyus, B.S; Raskovskaya, I.L

    2010-01-01

    This book describes the basic principles of laser refractography, a flexible new diagnostic tool for measuring optically inhomogeneous media and flows. Laser refractography is based on digital imaging and computer processing of structured laser beam refraction (SLR) in inhomogeneous transparent media. Laser refractograms provide both qualitative and quantitative measurements and can be used for the study of fast and transient processes. In this book, the theoretical basis of refractography is explored in some detail, and experimental setups are described for measurement of transparent media using either 2D (passed radiation) or 3D (scattered radiation) refractograms. Specific examples and applications are discussed, including visualization of the boundary layer near a hot or cold metallic ball in water, and observation of edge effects and microlayers in liquids and gases. As the first book to describe this new and exciting technique, this monograph has broad cross-disciplinary appeal and will be of interest t...

  16. Il laser

    CERN Document Server

    Smith, William V

    1974-01-01

    Verso il 1960, il laser era ancora "una soluzione alla ricerca di un problema", ma fin dagli anni immediatamente successivi si è rivelato uno strumento insostituibile per le applicazioni più svariate.

  17. Green lasers

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin

    2010-01-01

    Well over a dozen papers at this year's Photonics West meeting in San Francisco boasted improvements in harmonic generation to produce visible laser beams, most of them in the green spectral range......Well over a dozen papers at this year's Photonics West meeting in San Francisco boasted improvements in harmonic generation to produce visible laser beams, most of them in the green spectral range...

  18. Laser weapons

    Science.gov (United States)

    Tsipis, K.

    1981-12-01

    The potential for deploying lasers as an effective antimissile system is assessed. High intensity and precise collimation are noted as essential for lasers as weapons, although size and material properties determine the actual performance. Gas-dynamic, electron, and chemical lasers are reviewed as prime weapons candidates. Space-, ground-, and ship-based uses are considered; each demands precision pointing, involving movable mirrors, target tracking and condition sensors, and central processing for target choice, along with large capacity power generation and storage. Laser propagation in the atmosphere is degraded by absorption, scattering, thermal blooming, turbulence (causes diffraction), and plasma formation ahead of the beam. Different modes of damaging missiles are reviewed, and it is found that mirrored surfaces, ablative coatings, and fluid layers have significant abilities to protect a missile in-flight. Destroying an ICBM in the boost phase is calculated to require a one million MW generator, far beyond current power engineering capabilities. Conventional weapons are viewed as more effective than lasers, although high energy laser research may have definite applications in areas such as chemical engineering

  19. Pulsed laser deposition of thin refractory metal nitride films

    Science.gov (United States)

    Fernandez, Manuel; Bereznai, M.; Caricato, A. P.; D'Anna, Emilia; Juhasz, A.; Leggieri, Gilberto; Luches, Armando; Majni, Guiseppe; Martino, Maurizio; Mengucci, Paolo; Nagy, P. M.; Nanai, Laszlo; Toth, Zsolt

    2003-11-01

    We report on the deposition of thin transition metal nitride (TMN) films by ablating Mo, Ta, V and W targets in low-pressure (1, 10 and 100 Pa) nitrogen atmosphere by KrF excimer laser pulses, and on their characterization. The targets were foils of high purity (99.8%). 3" Si(111) wafers wre used as substrates. Film characteristics (composition, crystalline structure, hardness) were studied as a function of N2 pressure, KrF laser fluence (4.5-19 J/cm2), substrate temperature (20-750°C) and target to substrate distance (30-70 mm). Rutherford backscattering spectrometery (RBS) was used to calculate thickness of the films and identification of the composition. TMN films ar formed already at low N2 ambient pressures (1 Pa) and laser fluences (6 J/cm2) on substrates at room temperature. XRD investigations show that films deposited at elevated temperatures are mostly polycrystalline. While Mo, W and Ta nitrides show respectively a γ-Mo2N, β-W2N and δ-TaN phase in almost any deposition condition, vanadium nitride shows a prevalent phase of δ-VN at N2 pressures of 1-10 Pa, while at higher pressures (100 Pa) and at relatively high laser fluences (16-19 J/cm2) the dominant phase is β-V2N. Generally the crystallinity of the films improves by increasing the substrate temperature. Well-crystallinzed films are obtained on substrates heated at 500°C. Surface morphology, microhardness and electrical resistivity of the films are discussed as a function of both the nitrogen pressure and substrate temperature.

  20. Growth of cubic and hexagonal CdTe thin films by pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, S.K. [Solid State Physics Laboratory, Lucknow Road, Timarpur, Delhi 110 054 (India)]. E-mail: 628@ssplnet.org; Tiwari, Umesh [Solid State Physics Laboratory, Lucknow Road, Timarpur, Delhi 110 054 (India); Raman, R. [Solid State Physics Laboratory, Lucknow Road, Timarpur, Delhi 110 054 (India); Prakash, Chandra [Solid State Physics Laboratory, Lucknow Road, Timarpur, Delhi 110 054 (India); Krishna, Vamsi [Centre for Energy Studies, Indian Institute of Technology, New Delhi 110 016 (India); Dutta, Viresh [Centre for Energy Studies, Indian Institute of Technology, New Delhi 110 016 (India); Zimik, K. [Laser Science and Technology Centre, Metcalfe House, Delhi 110 054 (India)

    2005-02-01

    The paper reports the growth of cadmium telluride (CdTe) thin films by pulsed laser deposition (PLD) using excimer laser (KrF, {lambda}=248 nm, 10 Hz) on corning 7059 glass and SnO{sub 2}-coated glass (SnO{sub 2}/glass) substrates at different substrate temperatures (T{sub s}) and at different laser energy pulses. Single crystal target CdTe was used for deposition of thin films. With 30 min deposition time, 1.8- to {approx}3-{mu}m-thick films were obtained up to 200 deg. C substrate temperature. However, the film re-evaporates from the substrate surface at temperatures >275 deg. C. Atomic force microscopy (AFM) shows an average grain size {approx}0.3 {mu}m. X-ray diffraction analysis confirms the formation of CdTe cubic phase at all pulse energies except at 200 mJ. At 200 mJ laser energy, the films show hexagonal phase. Optical properties of CdTe were also investigated and the band gap of CdTe films were found as 1.54 eV for hexagonal phase and {approx}1.6 eV for cubic phase.