WorldWideScience

Sample records for excimer laser light

  1. Combination treatment with excimer laser and narrowband UVB light in vitiligo patients.

    Science.gov (United States)

    Shin, Sungsik; Hann, Seung-Kyung; Oh, Sang Ho

    2016-01-01

    For the treatment of vitiligo, narrowband UVB (NBUVB) light is considered the most effective for nonsegmental vitiligo, while excimer laser treatment is commonly used for localized vitiligo. However, treatment areas may potentially be missed with excimer laser treatment. We aimed to evaluate the effect of combinational treatment with NBUVB light and excimer laser on vitiligo. All patients were first treated with NBUVB; excimer laser was then applied in conjunction with NBUVB phototherapy due to a slow response or no further improvement with continuous NBUVB treatment alone. To minimize adverse effects, a fixed dose of NBUVB was administered, and the dose of excimer laser was increased based on patient response. Among 80 patients, 54 patients showed responses after combination with excimer laser; however, 26 patients (32.5%) showed no remarkable change after combination therapy. Of the 26 patients who showed no further response, 12 patients (46.1%) presented with vitiligo on the acral areas, which are known to the least responsive sites. Our study suggests that combined treatment of NBUVB and excimer laser in vitiligo may enhance the treatment response without remarkable side effects, therefore might also increase the compliance of the patients to the treatment. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Excimer laser applications

    International Nuclear Information System (INIS)

    Fantoni, R.

    1988-01-01

    This lecture deals with laser induced material photoprocessing, especially concerning those processes which are initiated by u.v. lasers (mostly excimer laser). Advantages of using the u.v. radiation emitted by excimer lasers, both in photophysical and photochemical processes of different materials, are discussed in detail. Applications concerning microelectronics are stressed with respect to other applications in different fields (organic chemistry, medicine). As further applications of excimer lasers, main spectroscopic techniques for ''on line'' diagnostics which employ excimer pumped dye lasers, emitting tunable radiation in the visible and near u.v. are reviewed

  3. Excimer Laser Technology

    CERN Document Server

    Basting, Dirk

    2005-01-01

    This comprehensive survey on Excimer Lasers investigates the current range of the technology, applications and devices of this commonly used laser source, as well as the future of new technologies, such as F2 laser technology. Additional chapters on optics, devices and laser systems complete this compact handbook. A must read for laser technology students, process application researchers, engineers or anyone interested in excimer laser technology. An effective and understandable introduction to the current and future status of excimer laser technology.

  4. Excimer Laser Curing Of Polymer Coatings

    Science.gov (United States)

    Klick, David; Akerman, M. Alfred; Paul, George L.; Supurovic, Darko; Tsuda, Haruki

    1988-12-01

    The use of the excimer laser as a source of energy for photo-assisted curing of industrial polymeric coatings was investigated. Presently, UV lamps are sometimes used to excite a photoinitiating molecule mixed with the starting monomers and oligomers of a coating. The resulting polymeric chain reaction multiplies the effect of the initial photons, making economical use of the light source. The high cost of laser photons may thus be justifiable if lasers provide advantages over lamps. A series of visibly transparent 7 μm coatings (a typical thickness for 'slick' magazine coatings) with various photoinitiators, monomers, and oligomers was illuminated with excimer laser light of various wavelengths, fluences, and pulse repetition rates. For the optimum parameters, it was found that the laser had large advantages in curing speed over existing UV lamp processes, due to its monochromaticity. Pigmented coatings (20 μm TiO2 mixtures typical of appliance or automotive finishes) are not easily cured with UV lamps due to the inability of light to penetrate the absorbing and scattering pigmented layer. However, economically-viable cure rates were achieved with certain photoinitiators using a tunable excimer-pumped dye laser. A prototype of such a laser suitable for factory use was built and used to cure these coatings. Results are scaled to a factory situation, and costs are calculated to show the advantages of the laser method over currently used processes.

  5. The Excimer Laser: Its Impact on Science and Industry

    Science.gov (United States)

    Basting, Dirk

    2010-03-01

    After the laser was demonstrated in 1960, 15 years were required to develop a practical method for extending laser emission into the UV: the Excimer laser. This historical review will describe the challenges with the new medium and provide an insight into the technological achievements. In the transition from Science to Industry it will be shown how start-ups successfully commercialized laboratory prototypes. The pioneers in this rapidly expanding field will be identified and the influence of government-funded research as well as the role of venture capital will be discussed. In scientific applications, the fields of photochemistry and material research were particularly stimulated by the advent of a reliable UV light source. Numerous industrial applications and worldwide research in novel applications were fueled In the early and mid 80's by progress in excimer laser performance and technology. The discovery of ablative photocomposition of polymer materials by Srinivasan at IBM opened the door to a multitude of important excimer applications. Micromachining with extreme precision with an excimer laser enabled the success of the inkjet printer business. Biological materials such as the human cornea can also be ``machined'' at 193nm, as proposed in 1983 by Trokel and Srinivasan. This provided the foundation of a new medical technology and an industry relying on the excimer laser to perform refractive surgery to correct vision Today, by far the largest use of the excimer laser is in photolithography to manufacture semiconductor chips, an application discovered by Jain at IBM in the early 80's. Moore's law of shrinking the size of the structure to multiply the number of transistors on a chip could not have held true for so long without the deep UV excimer laser as a light source. The presentation will conclude with comments on the most recent applications and latest market trends.

  6. 308-nm excimer laser in endodontics

    Science.gov (United States)

    Liesenhoff, Tim

    1992-06-01

    Root canal preparation was performed on 20 extracted human teeth. After opening the coronal pulp, the root canals were prepared by 308 nm excimer laser only. All root canals were investigated under SEM after separation in the axial direction. By sagittal separation of the mandibles of freshly slaughtered cows, it was possible to get access to the tissues and irradiate under optical control. Under irradiation of excimer laser light, tissue starts to fluoresce. It was possible to demonstrate that each tissue (dentin, enamel, bone, pulpal, and connective tissue) has a characteristic spectral pattern. The SEM analyses showed that it is well possible to prepare root canals safely. All organic soft tissue has been removed by excimer laser irradiation. There was no case of via falsa. The simultaneous spectroscopic identification of the irradiated tissue provides a safe protection from overinstrumentation. First clinical trials on 20 patients suffering of chronical apical parodontitis have been carried out successfully.

  7. Electrodeless excimer laser

    International Nuclear Information System (INIS)

    Lisi, N.

    2001-01-01

    In this paper it is proposed how to build an excimer laser based on an electrodeless discharge (or Dielectric Barrier Discharge). Such laser could operate with a low energy per pulse ( 2 excimer molecule, whose emission wavelength in the VUV range (157 nm) at high reprate is particularly interesting in the micro-lithography field [it

  8. Excimer laser: a module of the alopecia areata common protocol.

    Science.gov (United States)

    McMichael, Amy J

    2013-12-01

    Alopecia areata (AA) is an autoimmune condition characterized by T cell-mediated attack of the hair follicle. The inciting antigenic stimulus is unknown. A dense perbulbar lymphocytic infiltrate and reproducible immunologic abnormalities are hallmark features of the condition. The cellular infiltrate primarily consists of activated T lymphocytes and antigen-presenting Langerhans cells. The xenon chloride excimer laser emits its total energy at the wavelength of 308 nm and therefore is regarded as a "super-narrowband" UVB light source. Excimer laser treatment is highly effective in psoriasis, another T cell-mediated disorder that shares many immunologic features with AA. The excimer laser is superior in inducing T cell apoptosis in vitro compared with narrowband UVB, with paralleled improved clinical efficacy. The excimer laser has been used successfully in patients with AA. In this context, evaluation of the potential benefit of 308-nm excimer laser therapy in the treatment of AA is clinically warranted. Herein, the use of a common treatment protocol with a specifically designed module to study the outcome of excimer laser treatment on moderate-to-severe scalp AA in adults is described.

  9. Excimer laser corneal surgery and free oxygen radicals.

    Science.gov (United States)

    Bilgihan, K; Bilgihan, A; Akata, F; Hasanreisoğlu, B; Türközkan, N

    1996-01-01

    Corneal photoablation with 193 nm argon fluoride excimer laser is a new technique for the treatment of refractive errors and for removing corneal opacities and irregularities. Ultraviolet radiation and thermal injury induce free radical formation in the tissues. The aim of this study was to confirm the production of free radicals by excimer laser photoablation in rabbits. The thermal changes of the posterior corneal surface were recorded during excimer laser photoablation. The lipid peroxide (LPO) levels and superoxide dismutase (SOD) activities of aqueous humour were measured after excimer laser keratectomy. The aqueous LPO levels were not changed after excimer laser ablation, but both the thermal increase in the cornea during the photoablation and the decreased aqueous SOD activities suggest that free radicals are formed in the cornea during excimer laser keratectomy, and that they may be responsible for some of the complications of excimer laser corneal surgery.

  10. Calculation of high-pressure argon plasma parameters produced by excimer laser

    International Nuclear Information System (INIS)

    Tsuda, Norio; Yamada, Jun

    2000-01-01

    When a XeCl excimer laser light was focused in a high-pressure argon gas up to 150 atm, a dense plasma developed not only backward but also forward. It is important to study on the electron density and temperature of the laser-induced plasma in the high-pressure gas. The electron density and temperature in high-pressure argon plasma produced by XeCl excimer laser has been calculated and compared with the experimental data. (author)

  11. Excimer laser decontamination

    Science.gov (United States)

    Sentis, Marc L.; Delaporte, Philippe C.; Marine, Wladimir; Uteza, Olivier P.

    2000-04-01

    The application of excimer laser ablation process to the decontamination of radioactive surfaces is discussed. This technology is very attractive because it allows to efficiently remove the contaminated particles without secondary waste production. To demonstrate the capability of such technology to efficiently decontaminate large area, we studied and developed a prototype which include a XeCl laser, an optical fiber delivery system and an ablated particles collection cell. The main physical processes taking place during UV laser ablation will be explained. The influence of laser wavelength, pulse duration and absorption coefficient of material will be discussed. Special studies have been performed to understand the processes which limit the transmission of high average power excimer laser through optical fiber, and to determine the laser conditions to optimize the value of this transmission. An in-situ spectroscopic analysis of laser ablation plasma allows the real time control of the decontamination. The results obtained for painting or metallic oxides removal from stainless steel surfaces will be presented.

  12. 308nm Excimer Laser in Dermatology

    Science.gov (United States)

    Mehraban, Shadi

    2014-01-01

    308nm xenon-chloride excimer laser, a novel mode of phototherapy, is an ultraviolet B radiation system consisting of a noble gas and halide. The aim of this systematic review was to investigate the literature and summarize all the experiments, clinical trials and case reports on 308-nm excimer laser in dermatological disorders. 308-nm excimer laser has currently a verified efficacy in treating skin conditions such as vitiligo, psoriasis, atopic dermatitis, alopecia areata, allergic rhinitis, folliculitis, granuloma annulare, lichen planus, mycosis fungoides, palmoplantar pustulosis, pityriasis alba, CD30+ lympho proliferative disorder, leukoderma, prurigo nodularis, localized scleroderma and genital lichen sclerosus. Although the 308-nm excimer laser appears to act as a promising treatment modality in dermatology, further large-scale studies should be undertaken in order to fully affirm its safety profile considering the potential risk, however minimal, of malignancy, it may impose. PMID:25606333

  13. Electrodeless excimer laser; Laser a eccimeri senza elettrodi

    Energy Technology Data Exchange (ETDEWEB)

    Lisi, N. [ENEA, Divisione Nuovi Materiali, Centro Ricerche Casaccia, Rome (Italy)

    2001-07-01

    In this paper it is proposed how to build an excimer laser based on an electrodeless discharge (or Dielectric Barrier Discharge). Such laser could operate with a low energy per pulse (<100 mJ) and a high repetition rate (<100 kHz). The most relevant advantage an electrodeless DBD laser is the much longer gas mixture lifetime. This feature could allow the operation of a sealed laser emitting higher average power with respect to commercially available excimer lasers. Such discharge scheme could be advantageous in order to excite the F{sub 2} excimer molecule, whose emission wavelength in the VUV range (157 nm) at high reprate is particularly interesting in the micro-lithography field. [Italian] In questo documento viene proposto come costruire un laser a eccimeri basato su una scarica priva di elettrodi, o Dielectric Barrier Discharge. Tale laser puo' funzionare con una bassa energia per impulso (<100 mJ) ad alta frequenza di ripetizione (<100 kHz). Il vantaggio fondamentale di un laser a DBD e quindi privo di elettrodi e' la vita media della miscela gassosa molto piu' alta che potrebbe permettere alla camera laser di operare sigillata ad una potenza media superiore a quella dei laser a eccimeri attuali. Tale schema di pompaggio potrebbe essere particolarmente vantaggioso per eccitare la molecola eccimero F{sub 2} la cui lunghezza di emissione nel VUV (157 nm) ad elevata frequenza di ripetizione presenta un notevole interesse nel campo della produzione di microcircuiti.

  14. Excimer laser decomposition of silicone

    International Nuclear Information System (INIS)

    Laude, L.D.; Cochrane, C.; Dicara, Cl.; Dupas-Bruzek, C.; Kolev, K.

    2003-01-01

    Excimer laser irradiation of silicone foils is shown in this work to induce decomposition, ablation and activation of such materials. Thin (100 μm) laminated silicone foils are irradiated at 248 nm as a function of impacting laser fluence and number of pulsed irradiations at 1 s intervals. Above a threshold fluence of 0.7 J/cm 2 , material starts decomposing. At higher fluences, this decomposition develops and gives rise to (i) swelling of the irradiated surface and then (ii) emission of matter (ablation) at a rate that is not proportioned to the number of pulses. Taking into consideration the polymer structure and the foil lamination process, these results help defining the phenomenology of silicone ablation. The polymer decomposition results in two parts: one which is organic and volatile, and another part which is inorganic and remains, forming an ever thickening screen to light penetration as the number of light pulses increases. A mathematical model is developed that accounts successfully for this physical screening effect

  15. Overview on the high power excimer laser technology

    Science.gov (United States)

    Liu, Jingru

    2013-05-01

    High power excimer laser has essential applications in the fields of high energy density physics, inertial fusion energy and industry owing to its advantages such as short wavelength, high gain, wide bandwidth, energy scalable and repetition operating ability. This overview is aimed at an introduction and evaluation of enormous endeavor of the international high power excimer laser community in the last 30 years. The main technologies of high power excimer laser are reviewed, which include the pumping source technology, angular multiplexing and pulse compressing, beam-smoothing and homogenous irradiation, high efficiency and repetitive operation et al. A high power XeCl laser system developed in NINT of China is described in detail.

  16. [Glycosaminoglycans in subepithelial opacity after excimer laser keratectomy].

    Science.gov (United States)

    Nakayasu, K; Gotoh, T; Ishikawa, T; Kanai, A

    1996-05-01

    We evaluated histochemically the characteristics of glycosaminoglycans and proteoglycans in the corneal subepithelial opacity after excimer laser keratectomy on rabbit corneas. We also performed the same evaluations on the cornea after mechanical keratectomy. Twenty days after the operations, the area immediately subjacent to the epithelium showed strong staining with toluidine blue, alcian blue, and colloidal iron. However, after treatment with chondroitinase ABC or chondroitinase AC, alcian blue staining in this area decreased dramatically. Antilarge proteoglycan antibody also reacted strongly in this area. Histochemical and immunohistochemical examination of the cornea where mechanical keratectomy was done showed basically similar findings with the cornea of excimer laser keratectomy. These results suggest that large-molecula proteoglycans with chondroitine sulfate side chains become localized in the subepithelial area after two different kinds of keratectomies. We presume from histochemical and immunohistochemical observations that the subepithelial opacity observed after excimer laser keratectomy is not a special reaction to excimer laser but simply a corneal scar formed after stromal resection.

  17. Tunable excimer lasers

    International Nuclear Information System (INIS)

    Sze, R.C.

    1990-01-01

    The wide bandwidth nature of the rare-gas halide excimer transitions allow reasonable tuning of the laser oscillation wavelength that makes it useful for a number of applications. At the same time this wide bandwidth makes narrow band operation difficult and special techniques are needed to insure narrow frequency lasing as well as absolute frequency resettability. The author discusses briefly some of the classical frequency narrowing techniques and then goes on to some recent work that require lasers of special frequency characteristics for special applications including KrF laser fusion

  18. Laser spectroscopy of the products of photoevaporation with a short-wavelength (λ = 193 nm) excimer laser

    International Nuclear Information System (INIS)

    Gochelashvili, K S; Zemskov, M E; Evdokimova, O N; Mikhkel'soo, V T; Prokhorov, A M

    1999-01-01

    An excimer laser spectrometer was designed and constructed. It consists of a high-vacuum interaction chamber, a short-wavelength (λ = 193 nm) excimer ArF laser used for evaporation, a probe dye laser pumped by an XeCl excimer laser, and a system for recording a laser-induced fluorescence signal. This spectrometer was used to investigate nonthermal mechanisms of photoevaporation of a number of wide-gap dielectrics. (laser applications and other topics in quantum electronics)

  19. Matrix metalloproteinase expression in excimer laser wounded rabbit corneas

    Science.gov (United States)

    Hahn, Taewon; Chamon, Wallace; Akova, Yonja; Stark, Walter J.; Stetler-Stevenson, William G.; Azar, Dimitri T.

    1994-06-01

    This study was performed to obtain information about matrix metalloproteinase (MMP) expression in excimer-wounded corneas and to determine whether MMPs expression correlates with the depth of the ablation. 6-mm excimer keratectomy (60 or 180 micrometers ) was performed using the 193-mm ArF excimer laser on 12 NZW rabbits. Corneas treated with mechanical epithelial debridement and untreated corneas served as controls. Rabbits were killed at 20 and 30 hr after laser ablation. Zymography after SDS extraction was performed on regenerated central epithelium and the central stroma to determine MMPs expression. We observed enzymatic activity of a 92 KDa band in the epithelium of excimer-ablated corneas but not in that following debridement wounds and untreated controls. The expression of the 92 KDa MMP was most pronounced with the deeper excimer ablation. A 72 KDa band of enzymatic activity present in the stroma of all treated and control eyes was also seen in the epithelium of excimer-ablated corneas. These proteolytic enzymes may play an important role in wound healing and remodelling after excimer keratectomy.

  20. Recent advances in excimer laser technology at Los Alamos

    International Nuclear Information System (INIS)

    Bigio, I.J.; Czuchlewski, S.; McCown, A.W.; Taylor, A.J.

    1991-01-01

    This paper reports that current research in excimer laser technology at Los Alamos progresses in two major areas: In the Bright Source program, the development of ultra-high brightness (sub-piosecond) laser systems, based on discharge -pumped excimer laser amplifiers, continues Recently the authors have completed rigorous measurements of the saturation parameter for ultra-short pulses. In the laser fusion program, implementation of the large KrF laser fusion amplifiers have been accompanied by numerous studies of the laser physics and kinetics of large e-beam pumped devices

  1. High power excimer laser

    International Nuclear Information System (INIS)

    Oesterlin, P.; Muckenheim, W.; Basting, D.

    1988-01-01

    Excimer lasers emitting more than 200 W output power are not commercially available. A significant increase requires new technological efforts with respect to both the gas circulation and the discharge system. The authors report how a research project has yielded a laser which emits 0.5 kW at 308 nm when being UV preionized and operated at a repetition rate of 300 Hz. The laser, which is capable of operating at 500 Hz, can be equipped with an x-ray preionization module. After completing this project 1 kW output power will be available

  2. Laser dentistry: A new application of excimer laser in root canal therapy

    International Nuclear Information System (INIS)

    Pini, R.; Salimbeni, R.; Vannini, M.; Barone, R.; Clauser, C.

    1989-01-01

    We report the first study of the application of excimer lasers in dentistry for the treatment of dental root canals. High-energy ultraviolet (UV) radiation emitted by an XeCl excimer laser (308 nm) and delivered through suitable optical fibers can be used to remove residual organic tissue from the canals. To this aim, UV ablation thresholds of dental tissues have been measured, showing a preferential etching of infiltrated dentin in respect to healthy dentin, at laser fluences of 0.5-1.5 J/cm 2 . This technique has been tested on extracted tooth samples, simulating a clinical procedure. Fibers of decreasing core diameters have been used to treat different sections of the root canal down to its apical portion, resulting in an effective, easy, and fast cleaning action. Possible advantages of excimer laser clinical applications in respect to usual procedures are also discussed

  3. Excimer laser surface modification: Process and properties

    Energy Technology Data Exchange (ETDEWEB)

    Jervis, T.R.; Nastasi, M. [Los Alamos National Lab., NM (United States); Hirvonen, J.P. [Technical Research Institute, Espoo (Finland). Metallurgy Lab.

    1992-12-01

    Surface modification can improve materials for structural, tribological, and corrosion applications. Excimer laser light has been shown to provide a rapid means of modifying surfaces through heat treating, surface zone refining, and mixing. Laser pulses at modest power levels can easily melt the surfaces of many materials. Mixing within the molten layer or with the gas ambient may occur, if thermodynamically allowed, followed by rapid solidification. The high temperatures allow the system to overcome kinetic barriers found in some ion mixing experiments. Alternatively, surface zone refinement may result from repeated melting-solidification cycles. Ultraviolet laser light couples energy efficiently to the surface of metallic and ceramic materials. The nature of the modification that follows depends on the properties of the surface and substrate materials. Alloying from both gas and predeposited layer sources has been observed in metals, semiconductors, and ceramics as has surface enrichment of Cr by zone refinement of stainless steel. Rapid solidification after melting often results in the formation of nonequilibrium phases, including amorphous materials. Improved surface properties, including tribology and corrosion resistance, are observed in these materials.

  4. Advances in 193 nm excimer lasers for mass spectrometry applications

    Science.gov (United States)

    Delmdahl, Ralph; Esser, Hans-Gerd; Bonati, Guido

    2016-03-01

    Ongoing progress in mass analysis applications such as laser ablation inductively coupled mass spectrometry of solid samples and ultraviolet photoionization mediated sequencing of peptides and proteins is to a large extent driven by ultrashort wavelength excimer lasers at 193 nm. This paper will introduce the latest improvements achieved in the development of compact high repetition rate excimer lasers and elaborate on the impact on mass spectrometry instrumentation. Various performance and lifetime measurements obtained in a long-term endurance test over the course of 18 months will be shown and discussed in view of the laser source requirements of different mass spectrometry tasks. These sampling type applications are served by excimer lasers delivering pulsed 193 nm output of several mJ as well as fast repetition rates which are already approaching one Kilohertz. In order to open up the pathway from the laboratory to broader market industrial use, sufficient component lifetimes and long-term stable performance behavior have to be ensured. The obtained long-term results which will be presented are based on diverse 193 nm excimer laser tube improvements aiming at e.g. optimizing the gas flow dynamics and have extended the operational life the laser tube for the first time over several billion pulses even under high duty-cycle conditions.

  5. Treatment of alopecia areata with the 308-nm xenon chloride excimer laser: case report of two successful treatments with the excimer laser.

    Science.gov (United States)

    Gundogan, Cuneyt; Greve, Bärbel; Raulin, Christian

    2004-01-01

    Alopecia areata is a common disease of unknown etiology; it causes significant cosmetic and psycho-social distress for most of the people it affects. We report on an innovative form of treatment in two patients with typical alopecia areata on the capillitium. We successfully treated two patients whose alopecia areata had worsened progressively for 3 and 14 weeks. The treatment involved the use of a 308 nm xenon chloride excimer laser (dosage 300-2,300 mJ/cm(2) per session). After 11 and 12 sessions within a 9-week and 11-week period, the entire affected focus showed homogenous and thick regrowth. No relapse was observed during the follow-up period of 5 and 18 months. The use of the excimer laser is an effective, elegant, and safe means of treatment and has good tolerability. Analogous to topical treatment of alopecia areata, the immunosuppressive mechanism of the excimer laser can be interpreted as an induction of T-cell apoptosis. This new means of treatment has yet to be discussed in medical literature. Further studies with greater numbers are needed to assess its potential more precisely and evaluate the excimer laser in treating alopecia areata. Copyright 2004 Wiley-Liss, Inc.

  6. Myopic keratomileusis by excimer laser on a lathe.

    Science.gov (United States)

    Ganem, S; Aron-Rosa, D; Gross, M; Rosolen, S

    1994-01-01

    We designed an excimer laser keratomileusis delivery system to increase the regularity of the refractive cut surface and allow greater precision in the level and shape of the ablated zone. A parallel faced corneal disc was produced by microkeratectomy from six human eyes and surgical keratectomy in 12 beagle corneas. A 193-nanometer excimer laser that was used to project an oval beam onto the corneal disc was rotated on a flat surface to ensure overlapping of the ovally ablated areas between pulses. Electron microscopy of eye bank lenticules demonstrated a circular smooth regularly concave ablation zone. Histological examination of nine clear corneas confirmed thinning of the stroma without fibroblastic reaction and no epithelial hypertrophy. Mean preoperative corneal power of 43.15 +/- 2.18 decreased postoperatively to 33.61 +/- 2.34. The new technique of excimer laser keratomileusis has the advantage of a cut surface smoother and the clear zone is devoid of the stepwise concavity and irregularity seen in diaphragm based photoablation delivery systems.

  7. Green synthesis of selenium nanoparticles by excimer pulsed laser ablation in water

    OpenAIRE

    O. Van Overschelde; G. Guisbiers; R. Snyders

    2013-01-01

    Pure selenium nanoparticles were successfully synthesized by Liquid Phase - Pulsed Laser Ablation (LP-PLA) in de-ionized water. Excimer laser (248 nm) operating at low fluence (F ∼ 1 J/cm2) was used to generate colloidal solutions of selenium nanoparticles. The obtained selenium nanoparticles were characterized by UV-visible spectroscopy, Raman spectroscopy, Dynamic Light Scattering, and Transmission Electron Microscopy. We describe the multi-modal size distributions generated and use the cen...

  8. Optical design of high power excimer laser system

    International Nuclear Information System (INIS)

    Zhang Yongsheng; Zhao Jun; Ma Lianying; Yi Aiping; Liu Jingru

    2011-01-01

    Image relay and angular multiplexing,which should be considered together in the design of high power excimer laser system, is reviewed. It's important to select proper illumination setup and laser beam shaping techniques. Given the complex and special angular multiplexing scheme in high power excimer laser systems, some detailed conceptual layout schemes are given in the paper. After a brief description of lens array and reflective telescope objective, which combine the incoming beams to a common focus, a new schematic layout which uses the final targeting optics and one optical delay line array, to realize multiplexing and de-multiplexing simultaneously is first proposed in the paper. (authors)

  9. Excimer laser technology

    International Nuclear Information System (INIS)

    Mace, P.N.

    1980-01-01

    Scaling presently available excimer laser systems to lasers designed to operate at high average power and high pulse repetition rates for long periods of time requires advances in many areas of engineering technology. For economical application to industrial processes, the efficiency must be increased. This leads to more stringent requirements on preionization techniques, energy delivery systems, and system chemistry. Long life operation (> 10 9 to 10 10 pulses) requires development of new pulse power components, optical elements and flow system components. A broad-based program underway at the Los Alamos Scientific Laboratory is addressing these key technology issues, with the help of advanced component and systems development programs in industry. A prototype XeCl laser meeting all requirements for efficiency, system performance and life is scheduled for completion in 1984

  10. Effect of excimer laser (Arf, 193 nm) on aqueous humor during photorefractive keratectomy biophysical and biochemical study

    International Nuclear Information System (INIS)

    Mahmoud, S.S.; Mahmoud, A.A.

    2004-01-01

    Ultraviolet light (193 nm) produced by an excimer laser has been used to produce precise tissue ablation with minimal thermal damage to adjacent tissue. The present study was designed to investigate the effect of excimer laser during photo refractive keratectomy (PRK) on aqueous humor constituents and also the effect of antioxidant enzyme superoxide dismutase (SOD)- applied topically- on these changes if exist. Five groups of schenchilla rabbits were involved in this study, where four groups underwent corneal stromal ablation using argon fluoride excimer laser (Ar F, 193 nm). Two of these four groups were treated with superoxide dismutase intra operatively. The fifth group was used as control one. The obtained results revealed depletion of aqueous humor ascorbate and glutathione contents. Aqueous humor refractive index, cholesterol, phospholipids, malondialdehyde (MDA) and total protein were measured. In conclusion, the excimer laser can induce changes in aqueous humor constituents during PRK. These changes lasted at least for 24 hours and as the time increased to 4 weeks, these changes became limited. The use of exogenous SOD seems to exert beneficial effect on aqueous humor refractive index and total protein

  11. Excimer laser irradiation of metal surfaces

    Science.gov (United States)

    Kinsman, Grant

    In this work a new method of enhancing CO2 laser processing by modifying the radiative properties of a metal surface is studied. In this procedure, an excimer laser (XeCl) or KrF) exposes the metal surface to overlapping pulses of high intensity, 10(exp 8) - 10(exp 9) W cm(exp -2), and short pulse duration, 30 nsec FWHM (Full Width Half Maximum), to promote structural and chemical change. The major processing effect at these intensities is the production of a surface plasma which can lead to the formation of a laser supported detonation wave (LSD wave). This shock wave can interact with the thin molten layer on the metal surface influencing to a varying degree surface oxidation and roughness features. The possibility of the expulsion, oxidation and redeposition of molten droplets, leading to the formation of micron thick oxide layers, is related to bulk metal properties and the incident laser intensity. A correlation is found between the expulsion of molten droplets and a Reynolds number, showing the interaction is turbulent. The permanent effects of these interactions on metal surfaces are observed through scanning electron microscopy (SEM), transient calorimetric measurements and Fourier transform infrared (FTIR) spectroscopy. Observed surface textures are related to the scanning procedures used to irradiate the metal surface. Fundamental radiative properties of a metal surface, the total hemispherical emissivity, the near-normal spectral absorptivity, and others are examined in this study as they are affected by excimer laser radiation. It is determined that for heavily exposed Al surface, alpha' (10.6 microns) can be increased to values close to unity. Data relating to material removal rates and chemical surface modification for excimer laser radiation is also discussed. The resultant reduction in the near-normal reflectivity solves the fundamental problem of coupling laser radiation into highly reflective and conductive metals such as copper and aluminum. The

  12. Excimer laser for the treatment of psoriasis: safety, efficacy, and patient acceptability

    Directory of Open Access Journals (Sweden)

    Abrouk M

    2016-12-01

    Full Text Available Michael Abrouk,1 Ethan Levin,2 Merrick Brodsky,1 Jessica R Gandy,1 Mio Nakamura,2 Tian Hao Zhu,3 Benjamin Farahnik,4 John Koo,2 Tina Bhutani2 1Irvine School of Medicine, Irvine, 2Department of Dermatology, Psoriasis and Skin Treatment Center, University of California, San Francisco, 3Department of Dermatology, University of Southern California Keck School of Medicine, Los Angeles, CA, 4Department of Dermatology, University of Vermont College of Medicine, Burlington, VT, USA Introduction: The 308 nm excimer laser is a widely used device throughout the field of dermatology for many diseases including psoriasis. Although the laser has demonstrated clinical efficacy, there is a lack of literature outlining the safety, efficacy, and patient acceptability of the excimer laser. Methods: A literature search on PubMed was used with combinations of the terms “excimer”, “excimer laser”, “308 nm”, “psoriasis”, “protocol”, “safety”, “efficacy”, acceptability”, “side effects”, and “dose”. The search results were included if they contained information pertaining to excimer laser and psoriasis treatment and description of the safety, efficacy, and patient acceptability of the treatment. Results: The 308 nm excimer laser is generally safe and well tolerated with minimal side effects including erythema, blistering, and pigmentary changes. It has a range of efficacies depending on the protocol used with several different treatment protocols, including the induration protocol, the minimal erythema dose protocol, and the newer minimal blistering dose protocol. Conclusion: Although the excimer laser is not a first-line treatment, it remains an excellent treatment option for psoriasis patients and has been demonstrated to be an effective treatment with little to no side effects. Keywords: excimer, laser, 308 nm, psoriasis, safety, efficacy

  13. Laser drilling of metals with a XeCl excimer laser

    NARCIS (Netherlands)

    Schoonderbeek, A.

    2005-01-01

    This thesis is about laser drilling with a unique excimer laser with a nearly diffraction-limited beam and relatively long optical pulse duration of 175 ns. The combination of high processing speed and high processing quality suitable for industrial applications can be obtained because the excellent

  14. The development and progress of XeCl Excimer laser system

    Science.gov (United States)

    Zhang, Yongsheng; Ma, Lianying; Wang, Dahui; Zhao, Xueqing; Zhu, Yongxiang; Hu, Yun; Qian, Hang; Shao, Bibo; Yi, Aiping; Liu, Jingru

    2015-05-01

    A large angularly multiplexed XeCl Excimer laser system is under development at the Northwest Institute of Nuclear Technology (NINT). It is designed to explore the technical issues of uniform and controllable target illumination. Short wavelength, uniform and controllable target illumination is the fundamental requirement of high energy density physics research using large laser facility. With broadband, extended light source and multi-beam overlapping techniques, rare gas halide Excimer laser facility will provide uniform target illumination theoretically. Angular multiplexing and image relay techniques are briefly reviewed and some of the limitations are examined to put it more practical. The system consists of a commercial oscillator front end, three gas discharge amplifiers, two electron beam pumped amplifiers and the optics required to relay, encode and decode the laser beam. An 18 lens array targeting optics direct and focus the laser in the vacuum target chamber. The system is operational and currently undergoing tests. The total 18 beams output energy is more than 100J and the pulse width is 7ns (FWHM), the intensities on the target will exceed 1013W/cm2. The aberration of off-axis imaging optics at main amplifier should be minimized to improve the final image quality at the target. Automatic computer controlled alignment of the whole system is vital to efficiency and stability of the laser system, an array of automatic alignment model is under test and will be incorporated in the system soon.

  15. Modification of BSCCO surface by excimer laser annealing

    International Nuclear Information System (INIS)

    Ibi, A.; Akitsu, T.; Matsuzawa, H.

    2002-01-01

    Irradiation of Kr-F excimer laser onto the BSCCO calcined pellets changed their surface to be amorphous. SEM micrographs showed that sintering of the irradiated pellets recrystallized the surface layer and much reduced the intergrain gaps as compared with only sintered pellets, whereas the internal structure of the irradiated pellets remained unchanged. This processing made the surface-layer grains be tightly connected, resulting in the higher critical temperature than the conventionally sintered samples. We can say that excimer laser annealing process is a novel scheme to reduce the surface weak-link of the high Tc superconductors. (author)

  16. Alkali-vapor laser-excimer pumped alkali laser

    International Nuclear Information System (INIS)

    Yue Desheng; Li Wenyu; Wang Hongyan; Yang Zining; Xu Xiaojun

    2012-01-01

    Based on the research internal and overseas, the principle of the excimer pumped alkali laser (XPAL) is explained, and the advantages and disadvantages of the XPAL are analyzed. Taking into consideration the difficulties that the diode pumped alkali laser (DPAL) meets on its development, the ability to solve or avoid these difficulties of XPAL is also analyzed. By summing up the achievements of the XPAL, the possible further prospect is proposed. The XPAL is of possibility to improve the performance of the DPAL. (authors)

  17. Green synthesis of selenium nanoparticles by excimer pulsed laser ablation in water

    Directory of Open Access Journals (Sweden)

    O. Van Overschelde

    2013-10-01

    Full Text Available Pure selenium nanoparticles were successfully synthesized by Liquid Phase - Pulsed Laser Ablation (LP-PLA in de-ionized water. Excimer laser (248 nm operating at low fluence (F ∼ 1 J/cm2 was used to generate colloidal solutions of selenium nanoparticles. The obtained selenium nanoparticles were characterized by UV-visible spectroscopy, Raman spectroscopy, Dynamic Light Scattering, and Transmission Electron Microscopy. We describe the multi-modal size distributions generated and use the centrifugation method to isolate the smallest nanoparticles (∼60 nm in diameter.

  18. Treatment of oral lichen planus using 308-nm excimer laser.

    Science.gov (United States)

    Liu, Wei-Bing; Sun, Li-Wei; Yang, Hua; Wang, Yan-Fei

    2017-09-01

    Oral lichen planus (OLP) is a chronic inflammatory disease, has prolonged courses, repeated attacks and resistance to treatment. The traditional narrow spectrum UVB treatment has an established efficacy on skin lichen planus, and high safety. However, most of ultraviolet phototherapy devices have a huge volume, thereby cannot be used in the treatment of OLP. Lymphocytic infiltration is evident in the lesions of lichen planus, and the direct irradiation of 308-nm excimer laser can induce apoptosis of the T lymphocytes in skin lesions, thereby has a unique therapeutic effect on the diseases involving T lymphocytes. This study aims to investigate the efficacy of 308-nm excimer laser in the treatment of OLP. A total of six OLP patients were enrolled into this study, and further pathological diagnosis was conducted, then 308-nm excimer laser was used in the treatment. The efficacy of 308-nm excimer laser in the treatment of OLP was satisfactory. The clinical symptoms of five patients were significantly improved. In two patients, the erosion surface based on congestion and the surrounding white spots completely disappeared, and clinical recovery was achieved. Three patients achieved partial remission, that is, the erosion surface healed, congestion and white spot area shrunk by more than 1/2 of the primary skin lesions. In the remaining one patient, the erosion surface had not completely healed after treatment, and congestion and white spot area shrunk by less than 1/2 of the primary skin lesions. Only one patients had developed mild pain during the treatment, and this symptom alleviated by itself. The 308-nm excimer laser therapy can serve as a safe and effective treatment for OLP. © 2017 Wiley Periodicals, Inc.

  19. Photochemical and Spectroscopic Effects Resulting from Excimer Laser Excitation.

    Science.gov (United States)

    Wang, Xuan Xiao

    I. Photochemical production of ozone from pure oxygen using excimer lasers. Production of ozone was observed from experiments when oxygen was under a broadband pulsed KrF laser radiation. The production process was found to be autocatalytic. Mechanisms for the ozone formation were proposed. Experimental results over a range of oxygen pressure and laser pulse energy (irradiance) provided evidences in favor of the proposed mechanisms. Experiments were also numerically modeled. Good agreement between the experimental and the numerical results were observed, which provided further evidence to support the proposed mechanisms. Cross sections for some photochemical processes in the mechanisms were estimated. Production of ozone from pure oxygen under a ArF excimer laser radiation (193 nm) was also studied and numerically modeled. Effects of ambient water vapor on ozone production were investigated. Experimental results showed a fast ozone destruction when water vapor was present in the cell. However, numerical results obtained from the well-known OH and HO _2 chain ozone destruction mechanism predicted a slower ozone destruction. Possible reasons for the discrepancy are discussed. II. Resonance-enhanced multiphoton ionization of N_2 at 193 and 248 nm detected by N_sp{2}{+} fluorescence. Using a broadband excimer laser operating at 193 and 248 nm multiphoton ionization at high pressures in air and pure nitrogen has been detected by fluorescence from N_sp{2}{+} in the B-X firstnegative system. Measurements of the fluorescence intensity as a function of beam irradiance indicate resonance in N_2 at the energy of two 193 nm photons (2 + 1 REMPI) and three 248 nm photons (3 + 1 REMPI). Possible intermediate states are discussed. III. Excimer laser-induced fluorescence from some organic solvents. Fluorescence was observed from vapor phase benzene, toluene, p-xylene, benzyl chloride, methyl benzoate, acetic anhydride, ether, methanol, ethyl acetone, acetone, and 2-butanone using

  20. The effect of excimer laser keratectomy on corneal glutathione-related enzymes in rabbits.

    Science.gov (United States)

    Bilgihan, Ayşe; Bilgihan, Kamil; Yis, Ozgür; Yis, Nilgün Safak; Hasanreisoglu, Berati

    2003-04-01

    Glutathione related enzymes are involved in the metabolism and detoxification of cytotoxic and carcinogenic compounds as well as reactive oxygen species. Excimer laser is a very useful tool for the treatment of refractive errors and removing superficial corneal opacities. Previous studies have shown that excimer laser may initiate free radical formation in the cornea. In the present study, we evaluated the effect of excimer laser keratectomy on corneal glutathione-related enzyme activities in rabbits. Animals were divided into five groups, and all groups were compared with the controls (group 1), after epithelial scraping (group 2), transepithelial photorefractive keratectomy (PRK) (group 3), traditional PRK (group 4) and deep traditional PRK (group 5). Corneal glutathione peroxidase (GPx), glutathione S-transferase (GST) and glutathione reductase (GR) activities were measured after 24h. Corneal GPx and GR activities significantly decreased only in group 5 (p < 0.05) but GST activities significantly decreased in all groups when compared with the control group (p < 0.05). In conclusion, excimer laser inhibits the glutathione dependent defense system in the cornea, this effect becomes more prominent after high doses of excimer laser energy and antioxidants may be useful to reduce free radical mediated complications.

  1. 308-nm excimer laser for the treatment of alopecia areata.

    Science.gov (United States)

    Al-Mutairi, Nawaf

    2007-12-01

    Alopecia areata is loss of hair from localized or diffuse areas of hair-bearing area of the skin. Recently there are reports of efficacy of the 308-nm excimer radiation for this condition. To study the effect of the 308-nm excimer laser in the treatment of alopecia areata. Eighteen patients with 42 recalcitrant patches (including 1 adult with alopecia totalis) were enrolled in this study. The lesions were treated with the 308-nm excimer laser twice a week for a period of 12 weeks; one lesion on each patient was left as a control for comparison. There were 7 males and 11 females in this study. Regrowth of hair was observed in 17 (41.5%) patches. Thirteen of the 18 lesions in scalp showed a complete regrowth of hair. The extremity regions failed to show a response. Atopic diatheses had an unfavorable effect on the outcome in our patients. The 308-nm excimer laser is an effective therapeutic option for patchy alopecia areata of the scalp and for some cases with patchy alopecia areata of the beard area. It does not work for patchy alopecia areata of the extremities.

  2. Time Evolution of the Excimer State of a Conjugated Polymer Laser

    Directory of Open Access Journals (Sweden)

    Wafa Musa Mujamammi

    2017-11-01

    Full Text Available An excited dimer is an important complex formed in nano- or pico-second time scales in many photophysics and photochemistry applications. The spectral and temporal profile of the excimer state of a laser from a new conjugated polymer, namely, poly (9,9-dioctylfluorenyl-2,7-diyl (PFO, under several concentrations in benzene were investigated. These solutions were optically pumped by intense pulsed third-harmonic Nd:YAG laser (355-nm to obtain the amplified spontaneous emission (ASE spectra of a monomer and an excimer with bandwidths of 6 and 7 nm, respectively. The monomer and excimer ASEs were dependent on the PFO concentration, pump power, and temperature. Employing a sophisticated picosecond spectrometer, the time evolution of the excimer state of this polymer, which is over 400 ps, can be monitored.

  3. KrF excimer laser precision machining of hard and brittle ceramic biomaterials

    International Nuclear Information System (INIS)

    Huang, Yao-Xiong; Lu, Jian-Yi; Huang, Jin-Xia

    2014-01-01

    KrF excimer laser precision machining of porous hard–brittle ceramic biomaterials was studied to find a suitable way of machining the materials into various desired shapes and sizes without distorting their intrinsic structure and porosity. Calcium phosphate glass ceramics (CPGs) and hydroxyapatite (HA) were chosen for the study. It was found that KrF excimer laser can cut both CPGs and HA with high efficiency and precision. The ablation rates of CPGs and HA are respectively 0.081 µm/(pulse ⋅ J cm −2 ) and 0.048 µm/(pulse ⋅ J cm −2 ), while their threshold fluences are individually 0.72 and 1.5 J cm −2 . The cutting quality (smoothness of the cut surface) is a function of laser repetition rate and cutting speed. The higher the repetition rate and lower the cutting speed, the better the cutting quality. A comparison between the cross sections of CPGs and HA cut using the excimer laser and using a conventional diamond cutting blade indicates that those cut by the excimer laser could retain their intrinsic porosity and geometry without distortion. In contrast, those cut by conventional machining had distorted geometry and most of their surface porosities were lost. Therefore, when cutting hard–brittle ceramic biomaterials to prepare scaffold and implant or when sectioning them for porosity evaluation, it is better to choose KrF excimer laser machining. (paper)

  4. Comparative study of excimer and erbium:YAG lasers for ablation of structural components of the knee

    Science.gov (United States)

    Vari, Sandor G.; Shi, Wei-Qiang; van der Veen, Maurits J.; Fishbein, Michael C.; Miller, J. M.; Papaioannou, Thanassis; Grundfest, Warren S.

    1991-05-01

    This study was designed to compare the efficiency and thermal effect of a 135 ns pulsed-stretched XeCl excimer laser (308 nm) and a free-running Erbium:YAG laser (2940 nm) with 200 microsecond(s) pulse duration for ablation of knee joint structures (hyaline and fibrous cartilage, tendon and bone). The radiant exposure used for tissue ablation ranged from 2 to 15 J/cm2 for the XeCl excimer and from 33 to 120 J/cm2 for Er:YAG. The excimer and Er:YAG lasers were operated at 4 and 5 Hz respectively. The ablative laser energy was delivered to tissue through fibers. Ablation rates of soft tissues (hyaline and fibrous cartilage, tendon) varied from 8.5 to 203 micrometers /pulse for excimer and from 8.2 to 273 micrometers /pulse for Er:YAG lasers. Ablation rates of soft tissues are linearly dependent on the radiant exposure. Within the range of parameters tested all the tissues except the bone could be rapidly ablated by both lasers. Bone ablation was much less efficient, requiring 15 J/cm2 and 110 J/cm2 radiant exposure for excimer and Er:YAG lasers to ablate 9.5 and 8.2 micrometers tissue per pulse. However, excimer laser ablation produced less thermal damage in the tissues studied compared to Er:YAG at the same laser parameters. The authors conclude that both lasers are capable of efficient knee joint tissue ablation. XeCl excimer laser requires an order of magnitude less energy than Er:YAG laser for comparable tissue ablation.

  5. 3-D ASE calculation for high power output XeCl excimer lasers

    International Nuclear Information System (INIS)

    Tu Qinfen; Zhang Jianquan; Wu Baosheng

    1996-01-01

    The 3-dimensional ASE calculation for electron beam pumping XeCl excimer laser is presented by M-C method. In the model wall-reflected ASE is included. This calculation also includes non-saturable absorption and mirror that reflect ASE flux back into the active gain medium. Results show optimum scaling of injected flux. It can provide theoretical basis and experimental references for experiments on excimer lasers, and be extrapolated to any other type of laser

  6. Visual and refractive outcomes of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-q excimer lasers: a prospective, contralateral study.

    Science.gov (United States)

    Mearza, Ali A; Muhtaseb, Mohammed; Aslanides, Ioannis M

    2008-11-01

    To compare the safety, efficacy, and predictability of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer laser platforms. This prospective study comprised 44 eyes of 22 consecutive patients who were treated with LASIK using the Moria M2 microkeratome. One eye was treated with the SCHWIND ESIRIS laser and the fellow eye treated with the WaveLight ALLEGRETTO WAVE Eye-Q laser. All eyes operated with the SCHWIND ESIRIS were treated with standard aspheric ablation, whereas the eyes operated with the WaveLight ALLEGRETTO WAVE Eye-Q received treatment with three different ablation types according to the common practice at our clinic. Outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and proximity to target refraction at 6-month follow-up. At 6 months postoperative, mean decimal UCVA was 0.96+/-0.22 (range: 0.3 to 1.2) for ESIRIS eyes and 0.98+/-0.17 (range: 0.6 to 1.2) for ALLEGRETTO eyes (P=.57). Mean postoperative spherical equivalent refraction was -0.02+/-0.28 diopters (D) (range: -0.75 to +0.75 D) for ESIRIS eyes and 0.11+/-0.91 D (range: -1.00 to +3.88 D) for ALLEGRETTO eyes (P=.49). Of the ESIRIS eyes, 20/22 (91%) were within +/-1.00 D of target refraction and 20/22 (91%) were within +/-0.50 D of target refraction. Of the ALLEGRETTO eyes, 20/22 (91%) and 19/22 (86%) were within +/-1.00 D and +/-0.50 D, respectively, of target refraction. No patient lost > or =2 lines of BSCVA in either group. No differences were seen in safety and efficacy outcome parameters between the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer lasers when used according to a previously established treatment algorithm at our clinic in the treatment of refractive error.

  7. Semiconductor processing with excimer lasers

    International Nuclear Information System (INIS)

    Young, R.T.; Narayan, J.; Christie, W.H.; van der Leeden, G.A.; Rothe, D.E.; Cheng, L.J.

    1983-01-01

    The advantages of pulsed excimer lasers for semiconductor processing are reviewed. Extensive comparisons of the quality of annealing of ion-implanted Si obtained with XeCl and ruby lasers have been made. The results indicate that irrespective of the large differences in the optical properties of Si at uv and visible wavelengths, the efficiency of usage of the incident energy for annealing is comparable for the two lasers. However, because of the excellent optical beam quality, the XeCl laser can provide superior control of the surface melting and the resulting junction depth. Furthermore, the concentrations of electrically active point defects in the XeCl laser annealed region are 2 to 3 orders of magnitude lower than that obtained from ruby or Nd:YAG lasers. All these results seem to suggest that XeCl lasers should be suitable for fabricating not only solar cells but also the more advanced device structures required for VLSI or VHSIC applications

  8. Investigation on gas medium parameters for an ArF excimer laser through orthogonal experimental design

    Science.gov (United States)

    Song, Xingliang; Sha, Pengfei; Fan, Yuanyuan; Jiang, R.; Zhao, Jiangshan; Zhou, Yi; Yang, Junhong; Xiong, Guangliang; Wang, Yu

    2018-02-01

    Due to complex kinetics of formation and loss mechanisms, such as ion-ion recombination reaction, neutral species harpoon reaction, excited state quenching and photon absorption, as well as their interactions, the performance behavior of different laser gas medium parameters for excimer laser varies greatly. Therefore, the effects of gas composition and total gas pressure on excimer laser performance attract continual research studies. In this work, orthogonal experimental design (OED) is used to investigate quantitative and qualitative correlations between output laser energy characteristics and gas medium parameters for an ArF excimer laser with plano-plano optical resonator operation. Optimized output laser energy with good pulse to pulse stability can be obtained effectively by proper selection of the gas medium parameters, which makes the most of the ArF excimer laser device. Simple and efficient method for gas medium optimization is proposed and demonstrated experimentally, which provides a global and systematic solution. By detailed statistical analysis, the significance sequence of relevant parameter factors and the optimized composition for gas medium parameters are obtained. Compared with conventional route of varying single gas parameter factor sequentially, this paper presents a more comprehensive way of considering multivariables simultaneously, which seems promising in striking an appropriate balance among various complicated parameters for power scaling study of an excimer laser.

  9. Excimer lasers utilizing XeF and XeCl molecules

    Energy Technology Data Exchange (ETDEWEB)

    Bychkov, Yu I; Konovalov, I N; Losev, V F; Mesyats, G A; Ryzhov, V V; Tarasenko, V F; Fedorov, A I; Shemyakina, S B; Yastremskii, A G

    1978-12-01

    The results are given of an experimental and theoretical study of XeF (wavelength approx. 350 nm) and XeCl (wavelength approx. 308 nm) lasers excited by an electron beam, a discharge stabilized by an electron beam, and a rapid discharge. These lasers are representative of ones employing halides of noble gases, which are the most powerful sources of stimulated emission in the uv region. The XeCl laser is shown to have good emission characteristics with various methods of excitation. An analysis of the kinetics of processes in the plasma of lasers utilizing halides of noble gases showed that the main channel for the transfer of the beam's energy to the formation of excimer molecules is the ionic channel. An efficiency of about 2.6 percent and a specific radiant energy of 10 J.l/sup -1/ showed that XeCl* is one of the most effective excimer molecules.

  10. Assessment of the suitability of excimer lasers in treating onychomycosis

    International Nuclear Information System (INIS)

    Kymplová, Jaroslava; Dušek, Karel; Jelínek, Miroslav; Urzová, Jana; Mikšovský, Jan; Bauerová, Lenka

    2014-01-01

    Since it is known that UV-C radiation kills fungus, we wanted to verify the hypothesis that the use of excimer laser could be an alternative method for treating onychomycosis - nail fungus. The aim of the first stage of this work was to determine the transmission, reflection and absorption of nails. In the following stage we focused on irradiation of fungi. Our final task is to assess whether it is possible to determine the parameters of radiation (a total dose,a dose per pulse frequency, a repetition rate, a number of pulses) for which the elimination of fungi would be the most effective but without damaging the nail and soft tissue underneath it. The results so far have showed that UV-C radiation does not pass through a fingernail to such an extent that it could damage the soft tissue beneath it. Fungi are destroyed by the application of only small doses of radiation using the excimer laser. Additional measurements will be required to determine the modulation parameters of the excimer laser radiation for the treatment of onychomycosis.

  11. The argon excimer laser

    International Nuclear Information System (INIS)

    Wrobel, W.G.

    1981-02-01

    The electron-beam-pumped argon eximer laser is investigated and tuned for the first time. The electron beam is generated by means of an improved coaxial field emmision diode in which argon gas is excited with power densities of 0.3 GW/cm 3 for 18 ns. The processes in the excited gas of 20 to 65 bar are described in the context of a kinetic model as a sequence of stationary states. Investigations of the amplified spontaneous emission (superfluorescence) confirm the predictions of this model. Only the absorption due to the excited Ar atoms is anomalously high. Reproducible operation of the argon eximer laser was achieved in a wide pressure range with various resonator arrangements. The wavelength of this shortest wavelength of this shortest wavelength excimer laser is 126 nm, the laser line width approx. 1.7 nm, the pulse length 7 to 13 ns, and the laser power 250 kW. The laser emission is tuned from 123.2 nm to 128.4 nm by two different methods (diffraction grating and prism). This tunable laser is thus the one with the shortest wavelength at present. Its line width is 0.25 to 0.4 nm, and the power ue 1.7 kW. (orig.)

  12. Surface modification of polyethylene terephthalate using excimer and CO2 laser

    International Nuclear Information System (INIS)

    Mirzadeh, H.; Dadsetan, M.

    2002-01-01

    Complete text of publication follows. Attempts have been made to evaluate microstructuring which affects cell behaviour, physical and chemical changes produced by laser irradiation onto the polyethylene terephthalate (PET) surface. The surfaces of PET were irradiated using the CO 2 laser and KrF excimer pulsed laser. The changes in chemical and physical properties of the irradiated PET surface were investigated by attenuated total reflectance infrared spectroscopy (ATR-IR) and contact angle measurements. ATR-IR Spectra showed that the crystallinity in the surface region decreased due to the CO 2 laser and excimer laser irradiation. Scanning electron microscopy observations showed that the morphology of the laser irradiated PET surface changed due to laser irradiation. The results obtained from the cell behaviour studies revealed that changes of physico-chemical properties of the laser treated PET film have significantly changed in comparison with the unmodified PET

  13. Surface processing by high power excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Stehle, M [SOPRA, 92 - Bois-Colombes (France)

    1995-03-01

    Surface processing with lasers is a promising field of research and applications because lasers bring substantial advantages : laser beams work at distance, laser treatments are clean in respect of environment consideration and they offer innovative capabilities for surface treatment which cannot be reached by other way. Excimer lasers are pulsed, gaseous lasers which emit in UV spectral range - the most common are XeCl (308 nm), KrF (248 nm), ArF (193 nm). From 1980 up to 1994, many of them have been used for research, medical and industrial applications such as spectroscopy, PRK (photo-refractive keratotomy) and micro-machining. In the last six years, from 1987 up to 1993, efforts have been done in order to jump from 100 W average power up to 1 kW for XeCl laser at {lambda} = 308 nm. It was the aim of AMMTRA project in Japan as EU205 and EU213 Eureka projects in Europe. In this framework, SOPRA developed VEL (Very large Excimer Laser). In 1992, 1 kW (10 J x 100 Hz) millstone has been reached for the first time, this technology is based on X-Ray preionization and large laser medium (5 liters). Surface treatments based on this laser source are the main purpose of VEL Lasers. Some of them are given for instance : (a) Turbine blades made with metallic substrate and ceramic coatings on the top, are glazed in order to increase corrosion resistance of ceramic and metal sandwich. (b) Selective ablation of organic coatings deposited on fragile composite material is investigated in Aerospace industry. (c) Chock hardening of bulk metallic materials or alloys are investigated for automotive industry in order to increase wear resistance. (d) Ablation of thin surface oxides of polluted steels are under investigation in nuclear industry for decontamination. (J.P.N.).

  14. Surface processing by high power excimer laser

    International Nuclear Information System (INIS)

    Stehle, M.

    1995-01-01

    Surface processing with lasers is a promising field of research and applications because lasers bring substantial advantages : laser beams work at distance, laser treatments are clean in respect of environment consideration and they offer innovative capabilities for surface treatment which cannot be reached by other way. Excimer lasers are pulsed, gaseous lasers which emit in UV spectral range - the most common are XeCl (308 nm), KrF (248 nm), ArF (193 nm). From 1980 up to 1994, many of them have been used for research, medical and industrial applications such as spectroscopy, PRK (photo-refractive keratotomy) and micro-machining. In the last six years, from 1987 up to 1993, efforts have been done in order to jump from 100 W average power up to 1 kW for XeCl laser at λ = 308 nm. It was the aim of AMMTRA project in Japan as EU205 and EU213 Eureka projects in Europe. In this framework, SOPRA developed VEL (Very large Excimer Laser). In 1992, 1 kW (10 J x 100 Hz) millstone has been reached for the first time, this technology is based on X-Ray preionization and large laser medium (5 liters). Surface treatments based on this laser source are the main purpose of VEL Lasers. Some of them are given for instance : a) Turbine blades made with metallic substrate and ceramic coatings on the top, are glazed in order to increase corrosion resistance of ceramic and metal sandwich. b) Selective ablation of organic coatings deposited on fragile composite material is investigated in Aerospace industry. c) Chock hardening of bulk metallic materials or alloys are investigated for automotive industry in order to increase wear resistance. d) Ablation of thin surface oxides of polluted steels are under investigation in nuclear industry for decontamination. (J.P.N.)

  15. Photo-triggering and secondary electron produced ionization in electric discharge ArF* excimer lasers

    Science.gov (United States)

    Xiong, Zhongmin; Kushner, Mark J.

    2011-10-01

    Electric discharge excimer lasers are sustained in multi-atmosphere attaching gas mixtures that are typically preionized to enable a reproducible, uniform glow, which maximizes optical quality and gain. This preionization is often accomplished using UV light produced by a corona discharge within the plasma cavity. To quantify the relationship between corona discharge properties and those of the laser discharge, the triggering of electron avalanche by preionizing UV light in an electric discharge-pumped ArF* excimer laser was numerically investigated using a two-dimensional model. The preionizing UV fluxes were generated by a corona-bar discharge driven by the same voltage pulse as the main discharge sustained in a multi-atmospheric Ne/Ar/Xe/F2 gas mixture. The resulting peak photo-electron density in the inter-electrode spacing is around 108 cm-3, and its distribution is biased toward the UV source. The preionization density increases with increasing dielectric constant and capacitance of the corona bar. The symmetry and uniformity of the discharge are, however, improved significantly once the main avalanche develops. In addition to bulk electron impact ionization, the ionization generated by sheath accelerated secondary electrons was found to be important in sustaining the discharge current at experimentally observed values. At peak current, the magnitude of the ionization by sheath accelerated electrons is comparable to that from bulk electron impact in the vicinity of the cathode.

  16. Treatment of onychomycosis using radiation of excimer laser

    Czech Academy of Sciences Publication Activity Database

    Urzová, J.; Jelínek, Miroslav; Mikšovský, Jan; Kymplová, J.

    2013-01-01

    Roč. 647, JAN (2013), s. 636-641 ISSN 1022-6680 R&D Projects: GA MŠk LD12069 Institutional support: RVO:68378271 Keywords : excimer laser * UV-C radiation * nails * onychomycosis Subject RIV: BM - Solid Matter Physics ; Magnetism

  17. XeCl Excimer Laser For Micro - Machining Of Materials: Preliminary Theoretical And Experimental Works.

    Science.gov (United States)

    Iwanejko, Leszek; Pokora, Ludwik; Stefanski, Miroslaw; Ujda, Zbigniew

    1987-10-01

    The paper presents the results of preliminary investigations, both theoretical and experimental, of XeC1 excimer laser pumped by transverse electric discharge with UU preionization. The medium was a mixture of gases He-Xe-HC1. A theoretical model of the XeC1 laser was worked out and a lot of laser parameters calculations were done. In the same time an excimer laser operating on the mixture He-Xe-HC1 was started, the generation of laser radiation was of energy about 20mJ.

  18. A comparison of the characteristics of excimer and femtosecond laser ablation of acrylonitrile butadiene styrene (ABS)

    International Nuclear Information System (INIS)

    See, Tian Long; Liu, Zhu; Li, Lin; Zhong, Xiang Li

    2016-01-01

    Highlights: • Ablation threshold for excimer laser is lower compared to femtosecond laser. • Effective optical penetration depth for excimer laser is lower compared to femtosecond laser. • Two ablation characteristic regimes are observed for femtosecond laser ablation. • Reduction of C=C bond following excimer or fs laser ablation is observed. • Addition of oxygen- and nitrogen-rich functional groups is observed. - Abstract: This paper presents an investigation on the ablation characteristics of excimer laser (λ = 248 nm, τ = 15 ns) and femtosecond laser (λ = 800 nm, τ = 100 fs) on ABS polymer sheets. The laser–material interaction parameters (ablation threshold, optical penetration depth and incubation factor) and the changes in material chemical properties were evaluated and compared between the two lasers. The work shows that the ablation threshold and effective optical penetration depth values are dependent on the wavelength of laser beam (photon energy) and the pulse width. The ablation threshold value is lower for the excimer laser ablation of ABS (F_t_h = 0.087 J/cm"2) than that for the femtosecond laser ablation of ABS (F_t_h = 1.576 J/cm"2), demonstrating a more dominating role of laser wavelength than the pulse width in influencing the ablation threshold. The ablation depth versus the logarithmic scale of laser fluence shows two linear regions for the fs laser ablation, not previously known for polymers. The effective optical penetration depth value is lower for excimer laser ablation (α"−"1 = 223 nm) than that for femtosecond laser ablation (α"−"1 = 2917 nm). The ablation threshold decreases with increasing number of pulses (NOP) due to the chain scission process that shortens the polymeric chains, resulting in a weaker polymeric configuration and the dependency is governed by the incubation factor. Excimer laser treatment of ABS eliminates the C=C bond completely through the chain scission process whereas C=C bond is partially

  19. A comparison of the characteristics of excimer and femtosecond laser ablation of acrylonitrile butadiene styrene (ABS)

    Energy Technology Data Exchange (ETDEWEB)

    See, Tian Long, E-mail: tianlong.see@postgrad.manchester.ac.uk [Corrosion and Protection Centre, School of Materials, The Mill, The University of Manchester, M13 9PL Manchester (United Kingdom); Laser Processing Research Centre, School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL Manchester (United Kingdom); Liu, Zhu [Corrosion and Protection Centre, School of Materials, The Mill, The University of Manchester, M13 9PL Manchester (United Kingdom); Li, Lin [Laser Processing Research Centre, School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL Manchester (United Kingdom); Zhong, Xiang Li [Corrosion and Protection Centre, School of Materials, The Mill, The University of Manchester, M13 9PL Manchester (United Kingdom)

    2016-02-28

    Highlights: • Ablation threshold for excimer laser is lower compared to femtosecond laser. • Effective optical penetration depth for excimer laser is lower compared to femtosecond laser. • Two ablation characteristic regimes are observed for femtosecond laser ablation. • Reduction of C=C bond following excimer or fs laser ablation is observed. • Addition of oxygen- and nitrogen-rich functional groups is observed. - Abstract: This paper presents an investigation on the ablation characteristics of excimer laser (λ = 248 nm, τ = 15 ns) and femtosecond laser (λ = 800 nm, τ = 100 fs) on ABS polymer sheets. The laser–material interaction parameters (ablation threshold, optical penetration depth and incubation factor) and the changes in material chemical properties were evaluated and compared between the two lasers. The work shows that the ablation threshold and effective optical penetration depth values are dependent on the wavelength of laser beam (photon energy) and the pulse width. The ablation threshold value is lower for the excimer laser ablation of ABS (F{sub th} = 0.087 J/cm{sup 2}) than that for the femtosecond laser ablation of ABS (F{sub th} = 1.576 J/cm{sup 2}), demonstrating a more dominating role of laser wavelength than the pulse width in influencing the ablation threshold. The ablation depth versus the logarithmic scale of laser fluence shows two linear regions for the fs laser ablation, not previously known for polymers. The effective optical penetration depth value is lower for excimer laser ablation (α{sup −1} = 223 nm) than that for femtosecond laser ablation (α{sup −1} = 2917 nm). The ablation threshold decreases with increasing number of pulses (NOP) due to the chain scission process that shortens the polymeric chains, resulting in a weaker polymeric configuration and the dependency is governed by the incubation factor. Excimer laser treatment of ABS eliminates the C=C bond completely through the chain scission process whereas

  20. Collagen crosslinking for ectasia following PRK performed in excimer laser-assisted keratoplasty for keratoconus.

    Science.gov (United States)

    Spadea, Leopoldo

    2012-01-01

    To report the results of corneal collagen crosslinking (CXL) in a patient with corneal ectasia developed after excimer laser-assisted lamellar keratoplasty for keratoconus and a secondary photorefractive keratectomy (PRK) for residual refractive error. A 33-year-old woman, who had originally been treated for keratoconus in the right eye by excimer laser-assisted lamellar keratoplasty, subsequently had her residual ametropia treated by topographically guided, transepithelial excimer laser PRK. Five years after PRK, the patient developed corneal ectasia showing concomitant visual changes of best spectacle-corrected visual acuity (BSCVA) reduced to 20/33 with a refraction of -6.00 +6.00 × 30. The minimum corneal thickness at the ectasia apex was 406 µm. A treatment of riboflavin-UVA-induced corneal CXL was performed on the right eye. Two years after the CXL treatment, the right eye improved to 20/20 BSCVA with a refraction of plano +1.00 × 50 while exhibiting a clear lamellar graft. Corneal CXL provided safe and effective management of ectasia developed after excimer laser-assisted lamellar keratoplasty and PRK.

  1. A design of energy detector for ArF excimer lasers

    Science.gov (United States)

    Feng, Zebin; Han, Xiaoquan; Zhou, Yi; Bai, Lujun

    2017-08-01

    ArF excimer lasers with short wavelength and high photon energy are widely applied in the field of integrated circuit lithography, material processing, laser medicine, and so on. Excimer laser single pulse energy is a very important parameter in the application. In order to detect the single pulse energy on-line, one energy detector based on photodiode was designed. The signal processing circuit connected to the photodiode was designed so that the signal obtained by the photodiode was amplified and the pulse width was broadened. The amplified signal was acquired by a data acquisition card and stored in the computer for subsequent data processing. The peak of the pulse signal is used to characterize the single pulse energy of ArF excimer laser. In every condition of deferent pulse energy value levels, a series of data about laser pulses energy were acquired synchronously using the Ophir energy meter and the energy detector. A data set about the relationship between laser pulse energy and the peak of the pulse signal was acquired. Then, by using the data acquired, a model characterizing the functional relationship between the energy value and the peak value of the pulse was trained based on an algorithm of machine learning, Support Vector Regression (SVR). By using the model, the energy value can be obtained directly from the energy detector designed in this project. The result shows that the relative error between the energy obtained by the energy detector and by the Ophir energy meter is less than 2%.

  2. Change of wettability of PTFE surface by sputter etching and excimer laser. Sputter etching oyobi excimer laser ni yoru PTFE hyomen no shinsuika

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, S. (Nitto Denko Corp., Osaka (Japan)); Kubo, U. (Kinki University, Osaka (Japan))

    1994-06-20

    The wettability of PTFE (polytetrafluoroethylene) surfaces was improved by sputter etching and excimer laser irradiation. In sputter etching, the PTFE surface was treated by reactive sputter etching with H2O gas to give active groups on the surface. In laser irradiation, the surface was irradiated in pure water by high-energy KrF excimer laser. As the surface wettability was evaluated with a contact angle to water, the contact angle decreased remarkably in both treatments resulting in a good improvement effect. In sputter etching, various new chemical bonds such as F-C=O, F2C-FC-O, F2C-C-O and C-O were observed because of a decrease in F and incorporation of oxygen. Such chemical bonds could be eliminated by ultraviolet ray irradiation, and the treated surface condition approached the initial condition after irradiation of 200 hours. In laser irradiation, it was suggested that C-F bonds were broken, and OH groups were added to the surface by dissociation of H2O to H and OH. 7 refs., 8 figs., 1 tab.

  3. Offset-gated poly-Si TFTs using in-situ fluorine passivation and excimer laser doping

    International Nuclear Information System (INIS)

    Jung, Sang Hoon; Kim, Cheon Hong; Yoo, Juhn Suk; Han, Min Koo

    2000-01-01

    A new low-temperature poly-Si thin film transistor (TFT) fabrication method employing in-situ fluorine passivation and excimer-laser doping is proposed to fabricate offset-gated poly-Si TFTs. In the new process, the crystallization, the in-situ fluorine passivation of the active layer, and the doping of the source/drain region are performed simultaneously with only one step of excimer laser annealing while the conventional fabrication method requires two laser annealing steps. Employing phosphosilicate glass (PSG) films as a diffusion source, we successfully accomplished excimer laser doping. The subthreshold and the on-state characteristics of the device with in-situ fluorine passivation were considerably improved. This improvement was due to the fluorine passivation effects, which cured dangling bonds and strained bonds in the poly-Si channel, the offset region, and the SiO 2 /poly-Si interface

  4. Offset-gated poly-Si TFTs using in-situ fluorine passivation and excimer laser doping

    CERN Document Server

    Jung, S H; Yoo, J S; Han, M K

    2000-01-01

    A new low-temperature poly-Si thin film transistor (TFT) fabrication method employing in-situ fluorine passivation and excimer-laser doping is proposed to fabricate offset-gated poly-Si TFTs. In the new process, the crystallization, the in-situ fluorine passivation of the active layer, and the doping of the source/drain region are performed simultaneously with only one step of excimer laser annealing while the conventional fabrication method requires two laser annealing steps. Employing phosphosilicate glass (PSG) films as a diffusion source, we successfully accomplished excimer laser doping. The subthreshold and the on-state characteristics of the device with in-situ fluorine passivation were considerably improved. This improvement was due to the fluorine passivation effects, which cured dangling bonds and strained bonds in the poly-Si channel, the offset region, and the SiO sub 2 /poly-Si interface.

  5. Investigation of excimer laser ablation threshold of polymers using a microphone

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, Joerg; Niino, Hiroyuki; Yabe, Akira

    2002-09-30

    KrF excimer laser ablation of polyethylene terephthalate (PET), polyimide (PI) and polycarbonate (PC) in air was studied by an in situ monitoring technique using a microphone. The microphone signal generated by a short acoustic pulse represented the etch rate of laser ablation depending on the laser fluence, i.e., the ablation 'strength'. From a linear relationship between the microphone output voltage and the laser fluence, the single-pulse ablation thresholds were found to be 30 mJ cm{sup -2} for PET, 37 mJ cm{sup -2} for PI and 51 mJ cm{sup -2} for PC (20-pulses threshold). The ablation thresholds of PET and PI were not influenced by the number of pulses per spot, while PC showed an incubation phenomenon. A microphone technique provides a simple method to determine the excimer laser ablation threshold of polymer films.

  6. Triggering Excimer Lasers by Photoionization from Corona Discharges

    Science.gov (United States)

    Xiong, Zhongmin; Duffey, Thomas; Brown, Daniel; Kushner, Mark

    2009-10-01

    High repetition rate ArF (192 nm) excimer lasers are used for photolithography sources in microelectronics fabrication. In highly attaching gas mixtures, preionization is critical to obtaining stable, reproducible glow discharges. Photoionization from a separate corona discharge is one technique for preionization which triggers the subsequent electron avalanche between the main electrodes. Photoionization triggering of an ArF excimer laser sustained in multi-atmosphere Ne/Ar/F2/Xe gas mixtures has been investigated using a 2-dimensional plasma hydrodynamics model including radiation transport. Continuity equations for charged and neutral species, and Poisson's equation are solved coincident with the electron temperature with transport coefficients obtained from solutions of Boltzmann's equation. Photoionizing radiation is produced by a surface discharge which propagates along a corona-bar located adjacent to the discharge electrodes. The consequences of pulse power waveform, corona bar location, capacitance and gas mixture on uniformity, symmetry and gain of the avalanche discharge will be discussed.

  7. Prototype of an excimer laser for microprocessing

    Science.gov (United States)

    Iwanejko, Leszek; Pokora, Ludwik J.; Wolinski, Wieslaw L.

    1991-08-01

    The paper presents a brief description of a prototype of a XeC1 excimer laser for micraprocessing of materials. The planned main parameters of the laserare as follows: wavelength . . . . . . . . . . . . . . . . . . . . . . . . . 308 nm -''energyofapulse. . . . . . . . . . . . . lOOmJ -pulseduration (FWHM) . . . . . . . . . . . . . . . 2Ons repetition frequency . . . . . . . . . . . . . . 1O Hz peak power of a pulse . . . . . . . . . . . . . . . 5 MW With respect to currently carrried works with the prototype we show only preliminary results of testing of a laser head. The obtained maximum laser pulse energy exceeded 90 ml. However it should be pointed out that this value was obtained without any opt i mi z at i on of the 1 aser.

  8. 308-nm excimer laser ablation of human cartilage

    Science.gov (United States)

    Prodoehl, John A.; Rhodes, Anthony L.; Meller, Menachem M.; Sherk, Henry H.

    1993-07-01

    The XeCl excimer laser was investigated as an ablating tool for human fibrocartilage and hyaline cartilage. Quantitative measurements were made of tissue ablation rates as a function of fluence in meniscal fibrocartilage and articular hyaline cartilage. A force of 1.47 Newtons was applied to an 800 micrometers fiber with the laser delivering a range of fluences (40 to 190 mj/mm2) firing at a frequency of 5 Hz. To assess the effect of repetition rate on ablation rate, a set of measurements was made at a constant fluence of 60 mj/mm2, with the repetition rate varying from 10 to 40 Hz. Histologic and morphometric analysis was performed using light microscopy. The results of these studies revealed that the ablation rate was directly proportional to fluence over the range tested. Fibrocartilage was ablated at a rate 2.56 times faster than hyaline cartilage at the maximum fluence tested. Repetition rate had no effect on the penetration per pulse. Adjacent tissue damage was noted to be minimal (10 - 70 micrometers ).

  9. High Efficiency Mask Based Laser Materials Processing with TEA-CO2 - and Excimer Laser

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1997-01-01

    In general, mask based laser materials processing techniques suffer from a very low energy efficiency. We have developed a simple device called an energy enhancer, which is capable of increasing the energy efficiency of typical mask based laser materials processing systems. A short review of the ...... line marking with TEA-CO2 laser of high speed canning lines. The second one is manufactured for marking or microdrilling with excimer laser....

  10. 308-nm excimer laser for the treatment of alopecia areata in children.

    Science.gov (United States)

    Al-Mutairi, Nawaf

    2009-01-01

    Alopecia areata (AA) is a common skin disease which is characterized by nonscarring localized or diffused hair loss. In this study we assessed the efficacy of 308-nm Excimer laser in the treatment of alopecia areata in children. A total of 9 children with 30 recalcitrant patches alopecia areata and two children with alopecia areata totalis were enrolled in this study which included seven male and four female patients, aged between 4 and 14 years and the durations of their disease were between 7 and 25 months. All of these patients had more than one lesion of alopecia areata and at least one of them was left as a control for comparison. The lesions were treated with the 308-nm Excimer laser twice a week for a period of 12 weeks. Regrowth of hair was observed in 18 (60%) alopecia patches in the scalp, while there was no response in the control patches and over the extremities. Only four patients with scalp lesions showed a recurrence of alopecia after 6 months post laser therapy. So, 308-nm Excimer laser is considered an effective safe therapeutic option for patchy alopecia areata in children.

  11. XeCl Excimer Laser with Three- and Four-Component Mixture of Active Gases

    International Nuclear Information System (INIS)

    Iwanejko, L.; Pokora, L.

    1998-01-01

    Selected results of investigations of a XeCl excimer laser employing a new type (four-component)of mixture of gases, He-Kr:Xe-HCl, are presented. The mixture includes, instead of Xe, a mixture of not-separated Kr and Xe gases, much less expensive than pure xenon. A comparison of durations and energies of pulses generated in the XeCl excimer laser using three- or four-component gaseous active medium (He-Xe-HCl or He-Kr:Xe-HCl) is made. The investigations have been carried out with the use of a laser system with UV preionization and self sustained pumping discharge. (author)

  12. Application of optical tweezers and excimer laser to study protoplast fusion

    Science.gov (United States)

    Kantawang, Titirat; Samipak, Sompid; Limtrakul, Jumras; Chattham, Nattaporn

    2015-07-01

    Protoplast fusion is a physical phenomenon that two protoplasts come in contact and fuse together. Doing so, it is possible to combine specific genes from one protoplast to another during fusion such as drought resistance and disease resistance. There are a few possible methods to induce protoplast fusion, for example, electrofusion and chemical fusion. In this study, chemical fusion was performed with laser applied as an external force to enhance rate of fusion and observed under a microscope. Optical tweezers (1064 nm with 100X objective N.A. 1.3) and excimer laser (308 nm LMU-40X-UVB objective) were set with a Nikon Ti-U inverted microscope. Samples were prepared by soaking in hypertonic solution in order to induce cell plasmolysis. Elodea Canadensis and Allium cepa plasmolysed leaves were cut and observed under microscope. Concentration of solution was varied to induce difference turgor pressures on protoplasts pushing at cell wall. Free protoplasts in solution were trapped by optical tweezers to study the effect of Polyethylene glycol (PEG) solution. PEG was diluted by Ca+ solution during the process to induced protoplast cell contact and fusion. Possibility of protoplast fusion by excimer laser was investigated and found possible. Here we report a novel tool for plant cell fusion using excimer laser. Plant growth after cell fusion is currently conducted.

  13. Excimer laser beam profile recording based on electrochemical etched polycarbonate

    International Nuclear Information System (INIS)

    Parvin, P.; Jaleh, B.; Zangeneh, H.R.; Zamanipour, Z.; Davoud-Abadi, Gh.R.

    2008-01-01

    There is no polymeric detector used to register the beam profile of UV lasers. Here, a method is proposed for the measurement of intensive UV beam pattern of the excimer lasers based on the photoablated polycarbonate detector after coherent UV exposure and the subsequent electrochemical etching. UV laser induced defects in the form of self-microstructuring on polycarbonate are developed to replicate the spatial intensity distribution as a beam profiler

  14. Excimer laser beam profile recording based on electrochemical etched polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, P. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of); Laser Research Center, AEOI, P.O. Box 1165-8486, Tehran (Iran, Islamic Republic of)], E-mail: parvin@aut.ac.ir; Jaleh, B. [Physics Department, Bu-Ali Sina University, Postal Code 65174, Hamedan (Iran, Islamic Republic of); Zangeneh, H.R. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of); Zamanipour, Z. [Laser Research Center, AEOI, P.O. Box 1165-8486, Tehran (Iran, Islamic Republic of); Davoud-Abadi, Gh.R. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of)

    2008-08-15

    There is no polymeric detector used to register the beam profile of UV lasers. Here, a method is proposed for the measurement of intensive UV beam pattern of the excimer lasers based on the photoablated polycarbonate detector after coherent UV exposure and the subsequent electrochemical etching. UV laser induced defects in the form of self-microstructuring on polycarbonate are developed to replicate the spatial intensity distribution as a beam profiler.

  15. Automatic alignment of double optical paths in excimer laser amplifier

    Science.gov (United States)

    Wang, Dahui; Zhao, Xueqing; Hua, Hengqi; Zhang, Yongsheng; Hu, Yun; Yi, Aiping; Zhao, Jun

    2013-05-01

    A kind of beam automatic alignment method used for double paths amplification in the electron pumped excimer laser system is demonstrated. In this way, the beams from the amplifiers can be transferred along the designated direction and accordingly irradiate on the target with high stabilization and accuracy. However, owing to nonexistence of natural alignment references in excimer laser amplifiers, two cross-hairs structure is used to align the beams. Here, one crosshair put into the input beam is regarded as the near-field reference while the other put into output beam is regarded as the far-field reference. The two cross-hairs are transmitted onto Charge Coupled Devices (CCD) by image-relaying structures separately. The errors between intersection points of two cross-talk images and centroid coordinates of actual beam are recorded automatically and sent to closed loop feedback control mechanism. Negative feedback keeps running until preset accuracy is reached. On the basis of above-mentioned design, the alignment optical path is built and the software is compiled, whereafter the experiment of double paths automatic alignment in electron pumped excimer laser amplifier is carried through. Meanwhile, the related influencing factors and the alignment precision are analyzed. Experimental results indicate that the alignment system can achieve the aiming direction of automatic aligning beams in short time. The analysis shows that the accuracy of alignment system is 0.63μrad and the beam maximum restoration error is 13.75μm. Furthermore, the bigger distance between the two cross-hairs, the higher precision of the system is. Therefore, the automatic alignment system has been used in angular multiplexing excimer Main Oscillation Power Amplification (MOPA) system and can satisfy the requirement of beam alignment precision on the whole.

  16. Comparing laser induced plasmas formed in diode and excimer pumped alkali lasers.

    Science.gov (United States)

    Markosyan, Aram H

    2018-01-08

    Lasing on the D 1 transition (6 2 P 1/2 → 6 2 S 1/2 ) of cesium can be reached in both diode and excimer pumped alkali lasers. The first uses D 2 transition (6 2 S 1/2 → 6 2 P 3/2 ) for pumping, whereas the second is pumped by photoexcitation of ground state Cs-Ar collisional pairs and subsequent dissociation of diatomic, electronically-excited CsAr molecules (excimers). Despite lasing on the same D 1 transition, differences in pumping schemes enables chemical pathways and characteristic timescales unique for each system. We investigate unavoidable plasma formation during operation of both systems side by side in Ar/C 2 H 6 /Cs.

  17. Performance characteristics of an excimer laser (XeCl) with single ...

    Indian Academy of Sciences (India)

    2017-01-10

    Jan 10, 2017 ... Performance characteristics of an excimer laser (XeCl) with single-stage magnetic ... the stress can increase the lifetime of the switches and ..... work. References. [1] Ying-Tung Chen, Kris Naessens, Roel Bates, Yunn-Shiuan.

  18. Composition of the excimer laser-induced plume produced during LASIK refractive surgery

    Science.gov (United States)

    Glickman, Randolph D.; Liu, Yun; Mayo, George L.; Baribeau, Alan D.; Starck, Tomy; Bankhead, Tom

    2003-07-01

    Because of concerns about potential hazards to surgical personnel of the plume associated with laser refractive surgery, this study was performed to characterize the composition of such plumes. Filter elements were removed from the smoke evacuator of a VISX S3 excimer laser (filter pore size ~0.3 microns) and from a Mastel Clean Room ( filter pore size ~0.2 microns) used with a LADARVISION excimer laser. The filters from both laser systems captured the laser-induced plumes from multiple, routine, LASIK patient procedures. Some filters were processed for scanning electron microscopy, while others were extracted with methanol and chloroform for biochemical analysis. Both the VISX "Final Air" filter and the Mastel "Clean Room" filter captured material that was not observed in filters that had clean operating room air only passed through them. In the VISX system, air flows through the filter unit parallel to the filter matrix. SEM analysis showed these filters captured discrete particles of 0.3 to 3.0 microns in size. In the Mastel Clean Room unit, air flows orthogonally through the filter, and the filter matrix was heavily layered with captured debris so that individual particles were not readily distinguished. Amino acid analysis and gel electrophoresis of extracted material revealed proteinaceous molecules as large as 5000 molecular weight. Such large molecules in the laser plume are not predicted by the existing theory of photochemical ablation. The presence of relatively large biomolecules may constitute a risk of allergenic reactions in personnel exposed to the plume, and also calls into question the precise mechanism of excimer laser photochemical ablation. Supported by the RMG Research Endowment, and Research to Prevent Blindness

  19. Effectiveness of 308-nm Excimer Laser Therapy in Treating Alopecia Areata, Determined by Examining the Treated Sides of Selected Alopecic Patches.

    Science.gov (United States)

    Byun, Ji Won; Moon, Jong Hyuk; Bang, Chan Yl; Shin, Jeonghyun; Choi, Gwang Seong

    2015-01-01

    Some studies have reported the use of 308-nm excimer laser therapy for treating alopecia areata (AA); however, the effectiveness of this therapy on a theoretical basis has not yet been comparatively analyzed. To determine the therapeutic effect of excimer laser therapy on AA. One alopecic patch was divided into control and treated sides in 10 patients with AA. Then, 308-nm excimer laser therapy was administered twice a week for 12 weeks. Photograph and phototrichogram analyses were performed. Photographic assessments by both dermatologists and individuals of the general population showed objective improvements after excimer laser therapy. On the treated side, the hair count and hair diameter had statistically increased after treatment. However, only the hair diameter was found to be significantly high in the treated half when it was compared with the control side. The 308-nm excimer laser has a therapeutic effect on AA, which is proven by photograph and phototrichogram analysis by a side-by-side comparison. © 2015 S. Karger AG, Basel.

  20. Stability of a 1-kW excimer laser with long optical pulses

    NARCIS (Netherlands)

    Timmermans, J.C.M.; Hofmann, T.; Hofmann, Th.; van Goor, F.A.; Witteman, W.J.

    1996-01-01

    For high repetition operation of excimer-lasers care has to be taken of the changing performance of the electrical circuit, gas dynamic effects and contamination of the gas mixture to avoid deterioration of the laser performance. The parameters that influence the stability of the discharge are

  1. X-ray photoelectron spectroscopy study of excimer laser treated alumina films

    Science.gov (United States)

    Georgiev, D. G.; Kolev, K.; Laude, L. D.; Mednikarov, B.; Starbov, N.

    1998-01-01

    Amorphous alumina layers are deposited on a single crystal Si substrate by a e-gun evaporation technique. These films are then thermally annealed in oxygen to be crystallized and, further, irradiated with an excimer laser beam. At each stage of the film preparation, an x-ray photoelectron spectroscopy analysis is performed at the film surface and in depth, upon ion beam grinding. Results give evidence for the formation of an aluminosilicate upon thermal annealing of the film in oxygen. At the surface itself, this compound is observed to decompose upon excimer laser irradiation at energy densities exceeding 1.75 J/cm2, giving rise to free Si atoms and SiO2, however with complete disappearance of Al atoms. Model photochemical reactions are proposed to explain such transformations.

  2. Excimer laser superficial keratectomy for proud nebulae in keratoconus.

    Science.gov (United States)

    Moodaley, L; Liu, C; Woodward, E G; O'Brart, D; Muir, M K; Buckley, R

    1994-06-01

    Contact lens intolerance in keratoconus may be due to the formation of a proud nebula at or near the apex of the cone. Excimer laser superficial keratectomy was performed as an outpatients with proud nebulae as treatment patients with proud nebulae as treatment for their contact lens intolerance. The mean period of contact lens wear before the development of intolerance was 13.4 years (range 2 to 27 years). Following the development of intolerance, three patients abandoned contact lens wear in the affected eye while the remainder experienced a reduction in comfortable wearing time (mean = 3.75 hours; range: 0-14 hours). All patients had good potential Snellen visual acuity with a contact lens of 6/9 (nine eyes) and 6/12 (one eye). The proud nebulae were directly ablated with a 193 nm ArF excimer laser using a 1 mm diameter beam. Between 100-150 pulses were sufficient to ablate the raised area. Patients experienced no pain during the procedure and reported minimal discomfort postoperatively. In all cases flattening of the proud nebulae was achieved. Seven patients were able to resume regular contact lens wear (mean wearing time = 10.17 hours; range 8 to 16 hours). In three patients, resumption of contact lens wear was unsuccessful because of cone steepness. All patients achieved postoperative Snellen visual acuity of 6/12 or better with a contact lens. Four patients experienced a loss of one line in Snellen acuity. The mean follow up period was 8.3 months (range 2 to 17 months). Excimer laser superficial keratectomy is a useful technique for the treatment of contact lens intolerance caused by proud nebulae in patients with keratoconus. Penetrating keratoplasty is thus avoided.

  3. Analyses of surface coloration on TiO2 film irradiated with excimer laser

    International Nuclear Information System (INIS)

    Zheng, H.Y.; Qian, H.X.; Zhou, W.

    2008-01-01

    TiO 2 film of around 850 nm in thickness was deposited on a soda-lime glass by PVD sputtering and irradiated using one pulse of krypton-fluorine (KrF) excimer laser (wavelength of 248 nm and pulse duration of 25 ns) with varying fluence. The color of the irradiated area became darker with increasing laser fluence. Irradiated surfaces were characterized using optical microscopy, scanning electron microscopy, Raman spectroscopy and atomic force microscopy. Surface undergoes thermal annealing at low laser fluence of 400 and 590 mJ/cm 2 . Microcracks at medium laser fluence of 1000 mJ/cm 2 are attributed to surface melting and solidification. Hydrodynamic ablation is proposed to explain the formation of micropores and networks at higher laser fluence of 1100 and 1200 mJ/cm 2 . The darkening effect is explained in terms of trapping of light in the surface defects formed rather than anatase to rutile phase transformation as reported by others. Controlled darkening of TiO 2 film might be used for adjustable filters

  4. Random noise can help to improve synchronization of excimer laser pulses.

    Science.gov (United States)

    Mingesz, Róbert; Barna, Angéla; Gingl, Zoltán; Mellár, János

    2016-02-01

    Recently, we have reported on a compact microcontroller-based unit developed to accurately synchronize excimer laser pulses (Mingesz et al. 2012 Fluct. Noise Lett. 11, 1240007 (doi:10.1142/S021947751240007X)). We have shown that dithering based on random jitter noise plus pseudorandom numbers can be used in the digital control system to radically reduce the long-term drift of the laser pulse from the trigger and to improve the accuracy of the synchronization. In this update paper, we present our new experimental results obtained by the use of the delay-controller unit to tune the timing of a KrF excimer laser as an addition to our previous numerical simulation results. The hardware was interfaced to the laser using optical signal paths in order to reduce sensitivity to electromagnetic interference and the control algorithm tested by simulations was applied in the experiments. We have found that the system is able to reduce the delay uncertainty very close to the theoretical limit and performs well in real applications. The simple, compact and flexible system is universal enough to also be used in various multidisciplinary applications.

  5. High efficiency metal marking with CO2 laser and glass marking with excimer laser

    DEFF Research Database (Denmark)

    Bastue, Jens; Olsen, Flemmming Ove

    1997-01-01

    with a thoroughly tested ray-tracing model is presented and compared with experimental results. Special emphasis is put on two different applications namely marking in metal with TEA-CO2 laser and marking in glass with excimer laser. The results are evaluated on the basis of the achievable energy enhancement......Today, mask based laser materials processing and especially marking is widely used. However, the energy efficiency in such processes is very low [1].This paper gives a review of the results, that may be obtained using the energy enhancing technique [1]. Results of simulations performed...

  6. Scattered UV irradiation during VISX excimer laser keratorefractive surgery.

    Science.gov (United States)

    Hope, R J; Weber, E D; Bower, K S; Pasternak, J P; Sliney, D H

    2008-04-01

    To evaluate the potential occupational health hazards associated with scattered ultraviolet (UV) radiation during photorefractive keratectomy (PRK) using the VISX Star S3 excimer laser. The Laser Vision Center, National Naval Medical Center, Bethesda, Maryland, USA. Intraoperative radiometric measurements were made with the Ophir Power/Energy Meter (LaserStar Model PD-10 with silicon detector) during PRK treatments as well as during required calibration procedures at a distance of 20.3 cm from the left cornea. These measurements were evaluated using a worst-case scenario for exposure, and then compared with the American Conference of Governmental Industrial Hygeinists (ACGIH) Threshold Value Limits (TVL) to perform a risk/hazard analysis. During the PRK procedures, the highest measured value was 248.4 nJ/pulse. During the calibration procedures, the highest measured UV scattered radiation level was 149.6 nJ/pulse. The maximum treatment time was 52 seconds. Using a worst-case scenario in which all treatments used the maximum power and time, the total energy per eye treated was 0.132 mJ/cm2 and the total UV radiation at close range (80 cm from the treated eye) was 0.0085 mJ/cm2. With a workload of 20 patients, the total occupational exposure at 80 cm to actinic UV radiation in an 8-hour period would be 0.425 mJ/cm2. The scattered actinic UV laser radiation from the VISX Star S3 excimer laser did not exceed occupational exposure limits during a busy 8-hour workday, provided that operating room personnel were at least 80 cm from the treated eye. While the use of protective eyewear is always prudent, this study demonstrates that the trace amounts of scattered laser emissions produced by this laser do not pose a serious health risk even without the use of protective eyewear.

  7. Excimer laser beam delivery systems for medical applications

    Science.gov (United States)

    Kubo, Uichi; Hashishin, Yuichi; Okada, Kazuyuki; Tanaka, Hiroyuki

    1993-05-01

    We have been doing the basic experiments of UV laser beams and biotissue interaction with both KrF and XeCl lasers. However, the conventional optical fiber can not be available for power UV beams. So we have been investigating about UV power beam delivery systems. These experiments carry on with the same elements doped quartz fibers and the hollow tube. The doped elements are OH ion, chlorine and fluorine. In our latest work, we have tried ArF excimer laser and biotissue interactions, and the beam delivery experiments. From our experimental results, we found that the ArF laser beam has high incision ability for hard biotissue. For example, in the case of the cow's bone incision, the incision depth by ArF laser was ca.15 times of KrF laser. Therefore, ArF laser would be expected to harden biotissue therapy as non-thermal method. However, its beam delivery is difficult to work in this time. We will develop ArF laser beam delivery systems.

  8. Excimer-laser-induced activation of Mg-doped GaN layers

    International Nuclear Information System (INIS)

    Lin, Y.-J.; Liu, W.-F.; Lee, C.-T.

    2004-01-01

    In this study, we investigated the 248 nm excimer-laser-induced activation of the Mg-doped GaN layers. According to the observed photoluminescence results and the x-ray photoelectron spectroscopy measurements, we found that the dissociation of the Mg-H complexes and the formation of hydrogenated Ga vacancies (i.e., V Ga H 2 ) and/or the Ga vacancies occupied by interstitial Mg during the laser irradiation process, led to an increase in the hole concentration

  9. Comparison of KrF and ArF excimer laser treatment of biopolymer surface

    Energy Technology Data Exchange (ETDEWEB)

    Michaljaničová, I. [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic); Slepička, P., E-mail: petr.slepicka@vscht.cz [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic); Heitz, J.; Barb, R.A. [Institute of Applied Physics, Johannes Kepler University Linz, A-4040 Linz (Austria); Sajdl, P. [Department of Power Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic); Švorčík, V. [Department of Solid State Engineering, University of Chemistry and Technology, 166 28 Prague (Czech Republic)

    2015-06-01

    Highlights: • The influence of ArF and KrF laser on biopolymer surface was determined. • ArF laser acts predominantly on biopolymer surface. • PHB roughness is increased similarly for both applied wavelengths. • Roughness of nanostructures can be precisely controlled. • ArF laser introduces nitrogen on PHB surface. - Abstract: The goal of this work was the investigation of the impact of two different excimer lasers on two biocompatible and biodegradable polymers (poly-L-lactide and poly hydroxybutyrate). Both polymers find usage in medical and pharmaceutical fields. The polymers were modified by KrF and ArF excimer lasers. Subsequently the impact on surface morphology, surface chemistry changes, and thermal properties was studied by means of confocal and AFM microscopy, FTIR and XPS spectroscopy and DSC calorimetry. Under the same conditions of laser treatment it was observed that ArF laser causes more significant changes on surface chemistry, surface morphology and pattern formation on the polymers under investigation. The data obtained in this work can be used for a wide range of possible applications, in tissue engineering or in combination with metallization in electronics, e.g. for biosensors.

  10. Excimer Pumped Pulsed Tunable Dye Laser

    Science.gov (United States)

    Littman, Michael G.

    1988-06-01

    It has been recently shown and reported for the first time at this meeting, that Excimer pumping of a single-mode, short-cavity, grazing-incidence, longitudinally-pumped pulsed dye laser is feasible. In this paper the key concepts upon which this latest development is based are presented and are in a somewhat unusual form. This manuscript describes five specific dye laser examples. The five examples represent a progression from the simplest type of dye laser to the single-mode version mentioned above. The examples thus serve as a tutorial introduction to potential users of dye lasers. The article is organized into five sections or STEPS, each of which describes a different pulsed dye laser. Since the subtle points about dye lasers are best appreciated only after one actually attempts to build a working model, a PROCEDURES category is included in which details about the construction of the particular form of laser are given. As one reads through this category, think of it as looking over the shoulder of the laser builder. The NOTES category which follows is a brief but essential discussion explaining why various components and procedures are used, as well as how laser performance specifications are obtained. This subsection can he viewed as a discussion with the laser builder concerning the reasons for specific actions and choices made in the assembly of the example laser. The last category contains COMMENTS which provide additional related information pertaining to the example laser that goes beyond the earlier annotated discussion. If you like, these are the narrator's comments. At the end of the article, after the five sequential forms of the laser have been presented, there is a brief summation.

  11. Corneal aldehyde dehydrogenase and glutathione S-transferase activity after excimer laser keratectomy in guinea pigs.

    Science.gov (United States)

    Bilgihan, K; Bilgihan, A; Hasanreisoğlu, B; Turkozkan, N

    1998-03-01

    The free radical balance of the eye may be changed by excimer laser keratectomy. Previous studies have demonstrated that excimer laser keratectomy increases the corneal temperature, decreases the superoxide dismutase activity of the aqueous, and induces lipid peroxidation in the superficial corneal stroma. Aldehyde dehydrogenase (ALDH) and glutathione S-transferase (GST) are known to play an important role in corneal metabolism, particularly in detoxification of aldehydes, which are generated from free radical reactions. In three groups of guinea pigs mechanical corneal de-epithelialisation was performed in group I, superficial corneal photoablation in group II, and deep corneal photoablation in group III, and the corneal ALDH and GST activities measured after 48 hours. The mean ALDH and GST activities of group I and II showed no differences compared with the controls (p > 0.05). The corneal ALDH activities were found to be significantly decreased (p < 0.05) and GST activities increased (p < 0.05) in group III. These results suggest that excimer laser treatment of high myopia may change the ALDH and GST activities, metabolism, and free radical balance of the cornea.

  12. Subjective results of excimer laser correction of myopia. Review

    Directory of Open Access Journals (Sweden)

    V. N. Trubilin

    2012-01-01

    Full Text Available In review presents data of various authors regarding the subjective results excimer laser correction of myopia by LASIK. It was revealed that a group of patients with a high degree of dissatisfaction amounts to 4.6% of the total in all studies. High subjective results are confirmed by the positive dynamics of the «quality of life» of the patient.

  13. Ultraviolet excimer laser ablation: the effect of wavelength and repetition rate on in vivo guinea pig skin

    Energy Technology Data Exchange (ETDEWEB)

    Morelli, J.; Kibbi, A.G.; Farinelli, W.; Boll, J.; Tan, O.T.

    1987-06-01

    Multiple dermatologic conditions that are currently treated with traditional cold-knife surgery are amenable to laser therapy. The ideal surgical treatment would be precise and total removal of abnormal tissue with maximal sparing of remaining structures. The ultraviolet (UV) excimer laser is capable of such precise tissue removal due to the penetration depth of 193 nm and 248 nm irradiation of 1 micron per pulse. This type of ablative tissue removal requires a high repetition rate for efficient lesional destruction. Excimer laser radiation at 193 nm is capable of high repetition rates, which are necessary while 248 nm radiation causes increasing nonspecific thermal injury as the laser repetition rate is increased.

  14. Improvement of Anti-TNF-α Antibody-Induced Palmoplantar Pustular Psoriasis Using a 308-nm Excimer Light

    Directory of Open Access Journals (Sweden)

    Natsuko Iga

    2012-11-01

    Full Text Available Anti-tumor necrosis factor (TNF-α antibody is utilized in the treatment of a variety of chronic inflammatory conditions, including psoriasis. However, it can induce paradoxical development and/or exacerbation of psoriasis in the course of anti-TNF-α antibody treatment, which is sometimes refractory to conventional treatments. Herein, we report a case of refractory palmoplantar pustular psoriasis induced by anti-TNF-α antibody treatment, which was improved by treatment with a 308-nm excimer light. The 308-nm excimer light has less long-term risks than narrow-band UVB. The 308-nm excimer light may be a good therapeutic option for refractory psoriatic skin lesions induced by anti-TNF-α antibody therapy because of localized side effects without systemic problems, short length of treatment and low cumulative dosages of UV light.

  15. The application of excimer lasers for corneal sculpturing

    International Nuclear Information System (INIS)

    King, M.C.

    1990-01-01

    Of the broad selection of lasers available for surgery, the argon fluoride excimer laser offers a set of attributes that make it uniquely suited for the removal of corneal tissue. With ultraviolet radiation at 193mm, the energy of an individual photon (6.3 electron volts) is sufficient to break bonds in protein molecules without generating molecular vibration (heat). A single laser pulse is capable of removing 0.25 microns of corneal tissue over a well defined area 80 mm 2 in extent. This excision with a lateral precision to a fraction of a micron causes no discernible damage to neighboring cells. The smooth surface left after the tissue is removed promotes a quick and predictable regrowth of the epithelium. The penetration of radiation into the underlying tissue is the order of a micron so there is no potential harm to the lens or retinal tissue. Insignificant mutagenesis or unscheduled DNA synthesis has been detected as a result of tissue irradiation at this wavelength. In the past few years major progress has been made towards developing ophthalmic procedures which utilize the unique properties of this laser. To date there are FDA IDE's (Investigational Device Exemptions) for the following procedures: Photorefractive Keratectomy (PRK) or corneal reshaping for correcting near-sightedness, far-sightedness and astigmatism without the need for eye glasses, contact lenses or conventional refractive surgery (Radial Keratotomy); Partial Excimer Trabeculectomy for relieving the pressure build-up caused by glaucoma; T-Excisons for reducing astigmatism; Myopic Keratomileusis (MKM) for the refractive correction of severe myopia; superficial Keratectomy (corneal smoothing) for treating various corneal scars, dystrophies, recurrent corneal erosion etc. In this paper the fundamentals of beam tissue interaction at 193nm will be discussed

  16. Krypton excimer laser oscillation by discharge pumping

    International Nuclear Information System (INIS)

    Shirai, Takahiro; Tabe, Yoshitaka; Kubodera, Shoichi; Sasaki, Wataru; Kawanaka, Junji

    2001-01-01

    We have demonstrated vacuum ultraviolet (VUV) laser oscillation of the krypton excimer (Kr 2 *) excited by a compact self-sustained discharge device. We have observed a spectral narrowing of the Kr 2 * emission centered at 147.8 nm. A deconvoluted spectral width is 0.5 nm (FWHM), which reveals a contrast to a 13 nm spectral width of the spontaneous emission. The Kr 2 * intensity has increased one order of magnitude when a charging voltage was increased larger than 29 kV. The success of the lasing in the VUV spectral region has been attributed to the success of a stable glow discharge of Kr at 10 atm. The pulse width of the VUV laser radiation is 400 ns (FWHM). The maximum output energy measured is as large as 150 μJ. (author)

  17. Safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser.

    Science.gov (United States)

    Khoramnia, Ramin; Salgado, Josefina P; Wuellner, Christian; Donitzky, Christof; Lohmann, Chris P; Winkler von Mohrenfels, Christoph

    2012-09-01

    To evaluate the safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser (Concept System 1000; WaveLight GmbH, Erlangen, Germany). LASIK was performed on twenty eyes with myopia or myopic astigmatism (mean spherical equivalent refraction: -3.97±1.72 dioptres (D); mean cylinder: -0.84±0.77 D) using a microkeratome for flap creation and the Concept System 1000 for photoablation. Patients were examined preoperatively as well as 1, 3 and 6 months after the treatment. Manifest sphere and cylinder, uncorrected (UCDVA) and best corrected (BCDVA) distance visual acuity, corneal topography and pachymetry were analysed. We observed no adverse events that might have been associated with the use of a repetition rate of 1000 Hz. All eyes maintained or had improved BCDVA at 6 months after treatment when compared to preoperative values. Six months after LASIK, UCDVA was 20/20 or better in 85% and 20/25 or better in 100% of the eyes. The spherical equivalent refraction was within ±0.50 D in 95% of the eyes at 6 months after surgery. The refraction stayed stable over time; 95% of the eyes changedLASIK with the prototype 1000-Hz excimer laser was safe, efficient and predictable. The postoperative refraction was stable over time. There were no specific clinical side-effects that might be associated with the use of such a high repetition rate. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  18. Putative photoacoustic damage in skin induced by pulsed ArF excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, S.; Flotte, T.J.; McAuliffe, D.J.; Jacques, S.L.

    1988-05-01

    Argon-fluoride excimer laser ablation of guinea pig stratum corneum causes deeper tissue damage than expected for thermal or photochemical mechanisms, suggesting that photoacoustic waves have a role in tissue damage. Laser irradiation (193 nm, 14-ns pulse) at two different radiant exposures, 62 and 156 mJ/cm2 per pulse, was used to ablate the 15-microns-thick stratum corneum of the skin. Light and electron microscopy of immediate biopsies demonstrated damage to fibroblasts as deep as 88 and 220 microns, respectively, below the ablation site. These depths are far in excess of the optical penetration depth of 193-nm light (1/e depth = 1.5 micron). The damage is unlikely to be due to a photochemical mechanism because (a) the photons will not penetrate to these depths, (b) it is a long distance for toxic photoproducts to diffuse, and (c) damage is proportional to laser pulse intensity and not the total dose that accumulates in the residual tissue; therefore, reciprocity does not hold. Damage due to a thermal mechanism is not expected because there is not sufficient energy deposited in the tissue to cause significant heating at such depths. The damage is most likely due to a photoacoustic mechanism because (a) photoacoustic waves can propagate deep into tissue, (b) the depth of damage increases with increasing laser pulse intensity rather than with increasing total residual energy, and (c) the effects are immediate. These effects should be considered in the evaluation of short pulse, high peak power laser-tissue interactions.

  19. Refractive microlenses produced by excimer laser machining of poly(methyl methacrylate)

    DEFF Research Database (Denmark)

    Jensen, Martin Frøhling; Krühne, Ulrich; H., L.

    2005-01-01

    A method has been developed whereby refractive microlenses can be produced in poly (methyl methacrylate) by excimer laser irradiation at λ = 248 nm. The lenses are formed by a combined photochemical and thermal process. The lenses are formed as depressions in the substrate material (negative foca...

  20. [The 308 nm Excimer laser for the treatment of psoriasis and inflammatory skin diseases].

    Science.gov (United States)

    Fritz, K; Salavastru, C

    2018-01-01

    Overall, the 308 nm Excimer laser enables not only a more effective and safer UVB therapy than classical UV phototherapy, but also targeted irradiation in higher doses with a lower cumulative load, which results in faster healing of mainly circumscribed skin changes. This also applies to therapy-resistant residual lesions which, despite systemic therapy, did not diminish. Combination therapies usually improve the result and enable the dose of UVB and systemic medication to be reduced. Excimer laser therapy can be used for an increasing number of skin diseases, especially those that respond to phototherapy or photochemotherapy.

  1. Fabrication of biosynthetic vascular prostheses by 193-nm excimer laser radiation

    Science.gov (United States)

    Husinsky, Wolfgang; Csek, Ch.; Bartel, A.; Grabenwoeger, M.; Fitzal, F.; Wolner, Ernst

    1998-05-01

    This study was undertaken to investigate the feasibility of transmural capillary ingrowth into the inner surface of biosynthetic vascular prostheses (OmniflowTM) through perforations created by an excimer-laser, thus inducing an endothelial cell coverage. The biosynthetic vascular prostheses (10 cm length, 6 mm (phi) ) were perforated with an excimer laser ((phi) of the holes 50 - 100 micrometer, distance 4 mm) and implanted into the carotid arteries of 8 sheep. The laser tissue interaction process of 193 nm radiation ensures minimal thermal damage to the prostheses. They were compared to untreated OmniflowTM prostheses implanted at the contralateral side. Three months after implantation the prostheses were explanted and evaluated by gross morphology, histological examination and scanning electron microscopy. Scanning electron microscopy showed endothelial cells in the midgraft portion of all perforated prostheses, whereas collagen fibers, fibrin meshwork and activated platelets formed the inner layer in 6 out of 8 untreated OmniflowTM prostheses. It can be concluded, that spontaneous endothelialization of biosynthetic vascular prostheses can be achieved by transmural capillary ingrowth through perforations in the wall of the prostheses in an experimental sheep model.

  2. Visual and refractive outcomes following myopic laser-assisted subepithelial keratectomy with a flying-spot excimer laser.

    Science.gov (United States)

    McAlinden, Colm; Skiadaresi, Eirini; Moore, Jonathan E

    2011-05-01

    To investigate the visual and refractive outcomes following laser-assisted subepithelial keratectomy (LASEK) surgery with a flying-spot excimer laser. Private practice, Ireland. Case series. In this prospective study, the mean manifest spherical equivalent (SE), sphere, and cylinder were measured preoperatively. All eyes had LASEK surgery with an aberration-free algorithm with the Schwind Amaris excimer laser. Outcomes measured at 1 month, 6 months, and 1 year were uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity, contrast sensitivity, aberrometry, and complications. Accuracy, efficacy, and safety were evaluated at 1 year. Preoperatively, the mean SE, sphere, and cylinder in the 80 eyes (48 patients) were -3.58 diopters (D) ± 2.00 (SD), -3.23 ± 1.93 D, and -0.85 ± 0.65 D, respectively. One year postoperatively, the mean SE was -0.00 ± 0.22 D; 57 eyes (71%) were within -0.13 to +0.13 D of the SE, and 71 eyes (98%) were within ±0.50 D. The mean UDVA was -0.06 ± 0.07 logMAR, with an efficacy index of 1.04. The postoperative SE was stable between 1 month, 3 months, and 1 year. One eye (1%) had a change in SE by more than 0.50 D at 6 months and 1 year. There were no statistically significant differences in any aberrations at 1 year. The contrast sensitivity improved from 1.66 ± 0.17 log units preoperatively to 1.72 ± 0.15 log units at 1 month postoperatively (P=.0003), which was unchanged at 6 months and 1 year. This study demonstrated the effectiveness of LASEK for the treatment of myopia with this flying-spot excimer laser. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Fabrication of SERS Active Surface on Polyimide Sample by Excimer Laser Irradiation

    Directory of Open Access Journals (Sweden)

    T. Csizmadia

    2014-01-01

    Full Text Available A possible application of excimer laser irradiation for the preparation of surface enhanced Raman spectroscopy (SERS substrate is demonstrated. A polyimide foil of 125 μm thickness was irradiated by 240 pulses of focused ArF excimer laser beam (λ = 193 nm, FWHM = 20 ns. The applied fluence was varied between 40 and 80 mJ/cm2. After laser processing, the sample was coated with 40 nm silver by PLD in order to create a conducting layer required for the SERS application. The SERS activity of the samples was tested by Raman microscopy. The Raman spectra of Rhodamine 6G aqueous solution (c=10−3 mol/dm3 were collected from the patterned and metalized areas. For areas prepared at 40–60 mJ/cm2 laser fluences, the measured Raman intensities have shown a linear dependence on the applied laser fluence, while above 60 mJ/cm2 saturation was observed. The morphology of the SERS active surface areas was investigated by scanning electron microscopy. Finite element modeling was performed in order to simulate the laser-absorption induced heating of the polyimide foil. The simulation resulted in the temporal and spatial distribution of the estimated temperature in the irradiated polyimide sample, which are important for understanding the structure formation process.

  4. Pressure dependence of emission intensity of rare-gas excimer light produced by silent discharge; Teikiatsu ryoiki ni okeru musei hoden reiki ki gas excimer hikari shutsuryoku no atsuryoku izonsei

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Y.; Tanaka, M.; Yukimura, K. [Doshisha University, Kyoto (Japan)

    1996-09-20

    To establish the pressure dependence of silent discharge excited rare gas excimer light emission, a vacua ultraviolet light was subjected to spectroscopic analysis at a pressure lower than 20kPa. Researches are under way to apply the discharge excited rare gas excimer lamp as a vacuum ultraviolet light source for the development of new materials and for the conservation of environments. When the pressure is as low as 1.8kPa or 4.4kPa, the emission has peaks at wavelengths centering on 147nm and 149nm, both of which are the resonance lines of the xenon atom. Excimer generation becomes prominent as the pressure increases, with the second continuum of light growing dominant at 35kPa to weaken relatively the resonance lines and the first continuum of light. In the first continuum, emission increases only at a suppressed rate, as compared with emission in the second continuum, due for instance to a collision caused relaxation process in which excimers are lost. In the case of xenon in the vicinity of 10-11kPa, the first continuum of light and the second continuum of light are approximately equal in emission intensity, producing a vacuum ultraviolet light source with a bandwidth relatively large for a single gas spectrum. 14 refs., 11 figs.

  5. Physical and optical limitations using ArF-excimer and Er:YAG lasers for PRK

    Science.gov (United States)

    Semchishen, Vladimir A.; Mrochen, Michael; Seiler, Theo

    1998-06-01

    The Erbium:YAG laser emitting at a wavelength of 2,94 micrometer have been promised as an alternative laser for the ArF-excimer laser (193 nm) in photorefractive keratectomy (PRK). This report discusses the limitations of laser parameters such as wavelength, energy density and pulse duration for the ablation of the cornea. In addition, the melting process during ablation on the corneal surface roughness may play a role.

  6. Excimer laser processing of inkjet-printed and sputter-deposited transparent conducting SnO2:Sb for flexible electronics

    International Nuclear Information System (INIS)

    Cranton, Wayne M.; Wilson, Sharron L.; Ranson, Robert; Koutsogeorgis, Demosthenes C.; Chi Kuangnan; Hedgley, Richard; Scott, John; Lipiec, Stephen; Spiller, Andrew; Speakman, Stuart

    2007-01-01

    The feasibility of low-temperature fabrication of transparent electrode elements from thin films of antimony-doped tin oxide (SnO 2 :Sb, ATO) has been investigated via inkjet printing, rf magnetron sputtering and post-deposition excimer laser processing. Laser processing of thin films on both glass and plastic substrates was performed using a Lambda Physik 305i excimer laser, with fluences in the range 20-100 mJ cm -2 reducing sheet resistance from as-deposited values by up to 3 orders of magnitude. This is consistent with TEM analysis of the films that shows a densification of the upper 200 nm of laser-processed regions

  7. The effect of microarc oxidation and excimer laser processing on the microstructure and corrosion resistance of Zr–1Nb alloy

    International Nuclear Information System (INIS)

    Yang, Jiaoxi; Wang, Xin; Wen, Qiang; Wang, Xibing; Wang, Rongshan; Zhang, Yanwei; Xue, Wenbin

    2015-01-01

    The main purpose of this research was to investigate the effect of microarc oxidation (MAO) and excimer laser processing on the corrosion resistance of Zr–1Nb alloy in service environment. The pre-oxide film was fabricated on the surface of Zr–1Nb cladding tubes by MAO processing, and then subjected to KrF excimer laser irradiation. The surface morphology of the pre-oxide film was observed using a scanning electron microscope; phase compositions and quantities were determined using an X-ray diffraction; surface roughness was determined using a profilometer; and thermal expansion coefficient was measured using a dilatometer. Autoclave experiments were conducted for 94 days in an aqueous condition of 360 °C under 18.6 MPa in 0.01 mol/L LiOH solutions. The results showed that MAO + laser treatment resulted in a significant increase in the corrosion resistance of Zr–1Nb cladding tubes at high temperatures, because laser melting and etching could lead to a reduction in surface roughness and an increase in compactness of the pre-oxide film, and laser processing could promote the transformation of m-ZrO 2 phase to t-ZrO 2 phase. The best corrosion resistance was obtained when the pulse energy was 500 mJ, scanning speed was 0.13 mm/s, and pulse number was 2400. - Highlights: • Pre-oxide film was fabricated on Zr–1Nb cladding tube by MAO+ excimer laser processing. • Excimer laser processing induced the transformation of m-ZrO 2 to t-ZrO 2 . • The Rietveld quantitative analysis of the pre-oxide film was made. • We investigated the high temperature corrosion and corrosion mechanism of the oxide film. • The parameters of MAO+ excimer laser processing were optimized.

  8. The effect of microarc oxidation and excimer laser processing on the microstructure and corrosion resistance of Zr–1Nb alloy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jiaoxi, E-mail: yangjiaoxi@bjut.edu.cn [Institute of Laser Engineering, Beijing University of Technology, Beijing 100124 (China); Wang, Xin; Wen, Qiang; Wang, Xibing [Institute of Laser Engineering, Beijing University of Technology, Beijing 100124 (China); Wang, Rongshan; Zhang, Yanwei [Suzhou Nuclear Power Research Institute, Suzhou 215004 (China); Xue, Wenbin [College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2015-12-15

    The main purpose of this research was to investigate the effect of microarc oxidation (MAO) and excimer laser processing on the corrosion resistance of Zr–1Nb alloy in service environment. The pre-oxide film was fabricated on the surface of Zr–1Nb cladding tubes by MAO processing, and then subjected to KrF excimer laser irradiation. The surface morphology of the pre-oxide film was observed using a scanning electron microscope; phase compositions and quantities were determined using an X-ray diffraction; surface roughness was determined using a profilometer; and thermal expansion coefficient was measured using a dilatometer. Autoclave experiments were conducted for 94 days in an aqueous condition of 360 °C under 18.6 MPa in 0.01 mol/L LiOH solutions. The results showed that MAO + laser treatment resulted in a significant increase in the corrosion resistance of Zr–1Nb cladding tubes at high temperatures, because laser melting and etching could lead to a reduction in surface roughness and an increase in compactness of the pre-oxide film, and laser processing could promote the transformation of m-ZrO{sub 2} phase to t-ZrO{sub 2} phase. The best corrosion resistance was obtained when the pulse energy was 500 mJ, scanning speed was 0.13 mm/s, and pulse number was 2400. - Highlights: • Pre-oxide film was fabricated on Zr–1Nb cladding tube by MAO+ excimer laser processing. • Excimer laser processing induced the transformation of m-ZrO{sub 2} to t-ZrO{sub 2}. • The Rietveld quantitative analysis of the pre-oxide film was made. • We investigated the high temperature corrosion and corrosion mechanism of the oxide film. • The parameters of MAO+ excimer laser processing were optimized.

  9. AFM study of excimer laser patterning of block-copolymer: Creation of ordered hierarchical, hybrid, or recessed structures

    International Nuclear Information System (INIS)

    Švanda, Jan; Siegel, Jakub; Švorčík, Vaclav; Lyutakov, Oleksiy

    2016-01-01

    Highlights: • Combination of bottom-up (BCP separation) and top-down (laser patterning) technologies allows obtaining hierarchical structures. • Surface morphologies were determined by the order of patterning steps (laser modification, annealing, surface reconstruction). • Tuning the order of steps enables the reorientation of BCP domain at large scale, fabrication of hierarchical, hybrid or recessed structures. • The obtained structures can find potential applications in nanotechnology, plasmonics, information storage, sensors and smart surfaces. - Abstract: We report fabrication of the varied range of hierarchical structures by combining bottom-up self-assembly of block copolymer poly(styrene-block-vinylpyridine) (PS-b-P4VP) with top-down excimer laser patterning method. Different procedures were tested, where laser treatment was applied before phase separation and after phase separation or phase separation and surface reconstruction. Laser treatment was performed using either polarized laser light with the aim to create periodical pattern on polymer surface or non-polarized light for preferential removing of polystyrene (PS) part from PS-b-P4VP. Additionally, dye was introduced into one part of block copolymer (P4VP) with the aim to modify its response to laser light. Resulting structures were analyzed by XPS, UV–vis and AFM techniques. Application of polarized laser light leads to creation of structures with hierarchical, recessed or hybrid geometries. Non-polarized laser beam allows pronouncing the block copolymer phase separated structure. Tuning the order of steps or individual step conditions enables the efficient reorientation of block-copolymer domain at large scale, fabrication of hierarchical, hybrid or recessed structures. The obtained structures can find potential applications in nanotechnology, photonics, plasmonics, information storage, optical devices, sensors and smart surfaces.

  10. Outcomes for Myopic LASIK With the MEL 90 excimer laser.

    Science.gov (United States)

    Reinstein, Dan Z; Carp, Glenn I; Lewis, Tariq A; Archer, Timothy J; Gobbe, Marine

    2015-05-01

    To evaluate the visual outcomes of myopic LASIK performed with the MEL 90 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) using the Triple-A profile with a 500-Hz pulse rate. Retrospective analysis of the first 286 myopic LASIK procedures (147 patients) by two experienced surgeons in which the VisuMax femtosecond laser and MEL 90 excimer laser (Carl Zeiss Meditec) were used following a standardized surgical technique. Inclusion criteria were preoperative spherical equivalent refraction (SEQ) up to -10.38 diopters (D), cylinder up to 5.00 D, and corrected distance visual acuity (CDVA) of 20/25 or better. No nomogram adjustments were made. Patients were observed for 3 months. Flap thickness was between 80 and 110 µm and optical zone was between 6 and 7 mm. Standard outcomes analysis was performed. Preoperatively, mean SEQ was -3.83 ± 1.83 D (range: -0.13 to -10.38 D) and mean cylinder was -0.94 ± 0.86 D (range: 0.00 to -5.00 D). Mean age was 36.4 years (range: 18.2 to 74.1 years) with 50% female patients. Of this population, 138 eyes were treated by one surgeon and 148 eyes by another. The mean predictability of SEQ was -0.13 ± 0.34 D (range: -1.00 to +1.00 D). Postoperative SEQ was ± 0.50 D in 88% and ± 1.00 D in 100% of eyes. Preoperative CDVA was 20/20 or better in 97% of eyes. Postoperative uncorrected distance visual acuity was 20/20 or better in 92% and 20/25 or better in 99% of eyes. One line of CDVA was lost in 6% of eyes and no eyes lost two or more lines. There was statistically significant improvement in mesopic contrast sensitivity (CSV-1000) at 3 (P = .021), 6, 12, and 18 (all P ≤.001) cycles per degree. The MEL 90 excimer laser using the Triple-A ablation profile with a 500-Hz pulse rate was found to achieve a small but real increase in contrast sensitivity and high efficacy for myopia up to -10.00 D and cylinder up to 5.00 D without the need for a nomogram adjustment. Copyright 2015, SLACK Incorporated.

  11. Clinical results of PRK touch-up using Chiron/Technolas Keracor 116 excimer laser

    Science.gov (United States)

    Davidian, Mary E.; Keates, Richard H.; Ren, Qiushi

    1995-05-01

    Regression of effect as well as undercorrection are well established complications of excimer photorefractive keratectomy for the correction of myopia. In thirteen eyes initially treated with the VISX Taunton excimer laser and then retreated with the Chiron Technolas laser, the minimum follow-up time was six months. The mean postoperative refraction at six months was -0.442 +/- 0.996 D (diopters), significantly different from the pretreatment mean of -1.904 +/- 1.297 D. At six months after retreatment (10/13 eyes) 76.9% had an uncorrected visual acuity greater than or equal to 20/40 and (10/13 eyes) 76.9% were within 1 diopter of emmetropia. Only one eye had a significant increase in postoperative haze. The results of this study indicate that the majority of photorefractive keratectomy regressions and undercorrections can be successfully retreated.

  12. SBS pulse compression for excimer inertial fusion energy drivers

    International Nuclear Information System (INIS)

    Linford, G.J.

    1994-01-01

    A key requirement for the development of commercial fusion power plants utilizing inertial confinement fusion (ICF) as a source of thermonuclear power is the availability of reliable, efficient laser drivers. These laser drivers must be capable of delivering UV optical pulses having energies of the order of 5MJ to cryogenic deuterium-tritium (D/T) ICF targets. The current requirements for laser ICF target irradiation specify the laser wavelength, λ ca. 250 nm, pulse duration, τ p ca. 6 ns, bandwidth, Δλ ca. 0.1 nm, polarization state, etc. Excimer lasers are a leading candidate to fill these demanding ICF driver requirements. However, since excimer lasers are not storage lasers, the excimer laser pulse duration, τ pp , is determined primarily by the length of the excitation pulse delivered to the excimer laser amplifier. Pulsed power associated with efficiently generating excimer laser pulses has a time constant, τ pp which falls in the range, 30 τ p pp p . As a consequence, pulse compression is needed to convert the long excimer laser pulses to pulses of duration τ p . These main ICF driver pulses require, in addition, longer, lower power precursor pulses delivered to the ICF target before the arrival of the main pulse. Although both linear and non-linear optical (NLO) pulse compression techniques have been developed, computer simulations have shown that a ''chirped,'' self-seeded, stimulated Brillouin scattering (SBS) pulse compressor cell using SF 6 at a density, ρ ca. 1 amagat can efficiently compress krypton fluoride (KrF) laser pulses at λ=248 nm. In order to avoid the generation of output pulses substantially shorter than τ p , the optical power in the chirped input SBS ''seed'' beams was ramped. Compressed pulse conversion efficiencies of up to 68% were calculated for output pulse durations of τ p ca. ns

  13. Nebulae at keratoconus--the result after excimer laser removal.

    Science.gov (United States)

    Fagerholm, P; Fitzsimmons, T; Ohman, L; Orndahl, M

    1993-12-01

    Ten patients underwent excimer laser ablation due to nebula formation at keratoconus. The nebulae interfered significantly with contact lens fit or wearing time. The mean follow-up time in these patients was 16.5 months. Following surgery all patients could be successfully fitted with a contact lens and thereby obtain good visual acuity. Furthermore, contact lens wearing time was 8 hours or more in all cases. In 2 patients the nebulae recurred but were successfully retreated.

  14. Excimer laser phototherapeutic keratectomy.

    Science.gov (United States)

    Ayres, Brandon D; Rapuano, Christopher J

    2006-10-01

    Anterior corneal pathology, such as corneal scars and corneal stromal dystrophies, can be visually devastating. Over the past decade, there was a shift in treatment of these conditions from corneal transplantation to phototherapeutic keratectomy (PTK) using the 193 nm excimer laser for visual restoration. We have reviewed the recent literature on techniques for performing and refining PTK and also on various pathologic conditions that can be treated with PTK. The primary indications for PTK include anterior corneal dystrophies, such as lattice, granular, and Reis-Bückler's dystrophy. PTK can produce significant visual improvement in these patients, and corneal transplantation or retransplantation can be delayed. Corneal degenerations, such as Salzmann's nodular degeneration, keratoconus nodules, and climatic droplet keratopathy, also can be successfully treated with PTK. Additionally, anterior corneal scars from such etiologies as trauma, corneal ulcers, and prior refractive surgery can have visual improvement with PTK. In summary, PTK is a powerful tool for the management of anterior corneal pathology. In a properly selected and well-counseled patient, PTK can significantly improve vision and quality of life.

  15. Agglomeration of amorphous silicon film with high energy density excimer laser irradiation

    International Nuclear Information System (INIS)

    He Ming; Ishihara, Ryoichi; Metselaar, Wim; Beenakker, Kees

    2007-01-01

    In this paper, agglomeration phenomena of amorphous Si (α-Si) films due to high energy density excimer laser irradiation are systematically investigated. The agglomeration, which creates holes or breaks the continuous Si film up into spherical beads, is a type of serious damage. Therefore, it determines an upper energy limit for excimer laser crystallization. It is speculated that the agglomeration is caused by the boiling of molten Si. During this process, outbursts of heterogeneously nucleated vapor bubbles are promoted by the poor wetting property of molten silicon on the SiO 2 layer underneath. The onset of the agglomeration is defined by extrapolating the hole density as a function of the energy density of the laser pulse. A SiO 2 capping layer (CL) is introduced on top of the α-Si film to investigate its influence on the agglomeration. It is found that effects of the CL depend on its thickness. The CL with a thickness less than 300 nm can be used to suppress the agglomeration. A thin CL acts as a confining layer and puts a constraint on bubble burst, and hence suppresses the agglomeration

  16. XeCl excimer laser with new prism resonator configurations and its performance characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Benerji, N. S., E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in; Singh, A.; Varshnay, N.; Singh, Bijendra, E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in [Excimer Laser Section, LMPD, Raja Ramanna Center for Advanced Technology, Indore 452013 (India)

    2015-07-15

    New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configuration with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.

  17. Excimer-laser-induced permanent electrical conductivity in solid C60 films

    International Nuclear Information System (INIS)

    Ning, D.; Lou, Q.H.; Dong, J.X.; Wei, Y.R.

    1996-01-01

    After being irradiated in air by a XeCl (308 nm) excimer laser, the electrical conductivity of solid thin-film C 60 has been improved by more than six orders of magnitudes. The products resulting from laser irradiation of C 60 films have been investigated by Raman scattering and the onset of conductivity can be attributed to laser-induced oxygenation and disintegration of the fullerene. Irradiated by ∼40 ns laser pulses with different fluence, products with different microstructure were observed. At lower fluence, the Raman features of microcrystalline graphite and fullerene polymer were observed. At a fluence just below the ablation threshold (36 mJ/cm 2 ), the fullerene molecules in the film were disintegrated completely and transformed to amorphous graphite. (orig.). With 5 figs

  18. Study on Laser Induced Plasma Produced in Liquid

    International Nuclear Information System (INIS)

    Tsuda, N.; Yamada, J.

    2003-01-01

    When an intense laser light is focused in liquid, a hot plasma is produced at the focal spot. The breakdown threshold and the transmittance of sodium choroids solution are observed using excimer laser or YAG laser. The breakdown threshold decreases with increasing NaCl concentration. Threshold intensity of plasma produced by YAG laser is lower than excimer laser. The behavior of plasma development is observed by a streak camera. The plasma produced by a YAG laser develops only backward. However, the plasma produced by excimer laser develops not only backward but also forward same as the plasma development in high-pressure gases

  19. SBS pulse compression for excimer inertial fusion energy drivers

    Energy Technology Data Exchange (ETDEWEB)

    Linford, G.J. [TRW Space and Electronics Group, Redondo Beach, CA (United States). Space and Technology Div.

    1994-12-31

    A key requirement for the development of commercial fusion power plants utilizing inertial confinement fusion (ICF) as a source of thermonuclear power is the availability of reliable, efficient laser drivers. These laser drivers must be capable of delivering UV optical pulses having energies of the order of 5MJ to cryogenic deuterium-tritium (D/T) ICF targets. The current requirements for laser ICF target irradiation specify the laser wavelength, {lambda} ca. 250 nm, pulse duration, {tau}{sub p} ca. 6 ns, bandwidth, {Delta}{lambda} ca. 0.1 nm, polarization state, etc. Excimer lasers are a leading candidate to fill these demanding ICF driver requirements. However, since excimer lasers are not storage lasers, the excimer laser pulse duration, {tau}{sub pp}, is determined primarily by the length of the excitation pulse delivered to the excimer laser amplifier. Pulsed power associated with efficiently generating excimer laser pulses has a time constant, {tau}{sub pp} which falls in the range, 30 {tau}{sub p}<{tau}{sub pp}<100{tau}{sub p}. As a consequence, pulse compression is needed to convert the long excimer laser pulses to pulses of duration {tau}{sub p}. These main ICF driver pulses require, in addition, longer, lower power precursor pulses delivered to the ICF target before the arrival of the main pulse. Although both linear and non-linear optical (NLO) pulse compression techniques have been developed, computer simulations have shown that a ``chirped,`` self-seeded, stimulated Brillouin scattering (SBS) pulse compressor cell using SF{sub 6} at a density, {rho} ca. 1 amagat can efficiently compress krypton fluoride (KrF) laser pulses at {lambda}=248 nm. In order to avoid the generation of output pulses substantially shorter than {tau}{sub p}, the optical power in the chirped input SBS ``seed`` beams was ramped. Compressed pulse conversion efficiencies of up to 68% were calculated for output pulse durations of {tau}{sub p} ca. ns.

  20. Topography-guided treatment of irregular astigmatism with the wavelight excimer laser.

    Science.gov (United States)

    Jankov, Mirko R; Panagopoulou, Sophia I; Tsiklis, Nikolaos S; Hajitanasis, Georgos C; Aslanides, loannis M; Pallikaris, loannis G

    2006-04-01

    To evaluate the feasibility, safety, and predictability of correcting high irregular astigmatism in symptomatic eyes with the use of topography-guided photoablation. In a prospective, non-comparative case series, 16 consecutive symptomatic eyes of 11 patients with small hyperopic and myopic excimer laser optical zones, decentered and irregular ablation after corneal graft, and corneal scars were operated. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest and cycloplegic refraction, and corneal topography, with asphericity and regularity, were analyzed. LASIK (n = 10) and photorefractive keratectomy (n = 6) were performed using the ALLEGRETTO WAVE excimer laser and T-CAT software (Topography-guided Customized Ablation Treatment; WaveLight Laser Technologie AG, Erlangen, Germany). In the LASIK group, UCVA improved from 0.81 +/- 0.68 IogMAR (20/130) (range: 0.2 to 2.0) to 0.29 +/- 0.21 logMAR (20/39) (range: 0.1 to 0.7) at 6 months. In the PRK group, mean UCVA improved from 0.89 +/- 0.87 IogMAR (20/157) (range: 0.1 to 2.0) to 0.42 +/- 0.35 logMAR (20/53) (range: 0.1 to 1.0) at 6 months. Best spectacle-corrected visual acuity did not change significantly in either group. One PRK patient lost one line of BSCVA. Refractive cylinder for the LASIK group improved from -2.53 +/- 1.71 diopters (D) (range: -0.75 to -5.75 D) to -1.28 +/- 0.99 D (range: 0 to -2.50 D) at 6 months. Refractive cylinder in the PRK group improved from -2.21 +/- 2.11 D (range: -0.25 to -5.50 D) to -1.10 +/- 0.42 D (range: -0.50 to -1.50 D). Index of surface irregularity showed a decrease from 60 +/- 12 (range: 46 to 89) to 50 +/- 9 (range: 32 to 63) at 6 months in the LASIK group whereas no significant change was noted in the PRK group. Subjective symptoms, such as glare, halos, ghost images, starbursts, and monocular diplopia, were not present postoperatively. Topography-guided LASIK and PRK resulted in a significant reduction of refractive cylinder and

  1. Effect of volatile compounds on excimer laser power delivery.

    Science.gov (United States)

    Van Horn, Stewart D; Hovanesian, John A; Maloney, Robert K

    2002-01-01

    To determine whether vapors from perfume, hairspray, oil-based paint, or water-based paint affect excimer laser beam power delivery at the corneal surface. We measured the power delivery of an Apex Plus laser before, during, and after exposure to vapors from the following volatile compounds: three types of perfume, hair spray, an oil-based paint, and a water-based paint. A digital calorimeter was used to measure the steady-state beam power of the laser during laser discharge at the corneal plane. Multiple trials were run with each compound, and the change in laser energy over time was examined to determine if any of the compounds caused degradation of the laser optics. The presence of a volatile compound in the room caused no change in mean laser energy in comparison to before and after the compound was present. However, perfumes caused a progressive decline in laser beam power throughout the trials. Controlling for this progressive decline, there was no significant difference from perfume to perfume. None of the compounds tested caused a decline in laser beam power while present in the room. However, the presence of any perfume caused a deterioration in beam power over time, suggesting a degradation of the laser optics for all perfumes. Laser centers should consider advising their patients and staff to not wear perfumes in the laser suite.

  2. Time-resolved spectroscopy and fluorescence resonance energy transfer in the study of excimer laser damage of chromatin

    Energy Technology Data Exchange (ETDEWEB)

    Radu, L. [Department of Molecular Genetics and Radiobiology, Babes National Institute, Bucharest (Romania)], E-mail: lilianajradu@yahoo.fr; Mihailescu, I. [Department of Lasers, Laser, Plasma and Radiation Physics Institute, Bucharest (Romania); Radu, S. [Department of Computer Science, Polytechnics University, Bucharest (Romania); Gazdaru, D. [Department of Biophysics, Bucharest University (Romania)

    2007-09-21

    The analysis of chromatin damage produced by a 248 nm excimer laser radiation, for doses of 0.3-3 MJ/m{sup 2} was carried out by time-resolved spectroscopy and fluorescence resonance energy transfer (FRET). The chromatin was extracted from a normal and a tumoral tissue of Wistar rats. The decrease with laser dose of the relative contribution of the excited state lifetimes of ethidium bromide (EtBr) bounded to chromatin constitutes an evidence of the reduction of chromatin deoxyribonucleic acid (DNA) double-strand structure. FRET was performed from dansyl chloride to acridine orange, both coupled to chromatin. The increase of the average distance between these ligands, under the action of laser radiation, reflects a loosening of the chromatin structure. The radiosensitivity of tumor tissue chromatin is higher than that of a normal tissue. The determination of the chromatin structure modification in an excimer laser field can be of interest in laser therapy.

  3. Time-resolved spectroscopy and fluorescence resonance energy transfer in the study of excimer laser damage of chromatin

    International Nuclear Information System (INIS)

    Radu, L.; Mihailescu, I.; Radu, S.; Gazdaru, D.

    2007-01-01

    The analysis of chromatin damage produced by a 248 nm excimer laser radiation, for doses of 0.3-3 MJ/m 2 was carried out by time-resolved spectroscopy and fluorescence resonance energy transfer (FRET). The chromatin was extracted from a normal and a tumoral tissue of Wistar rats. The decrease with laser dose of the relative contribution of the excited state lifetimes of ethidium bromide (EtBr) bounded to chromatin constitutes an evidence of the reduction of chromatin deoxyribonucleic acid (DNA) double-strand structure. FRET was performed from dansyl chloride to acridine orange, both coupled to chromatin. The increase of the average distance between these ligands, under the action of laser radiation, reflects a loosening of the chromatin structure. The radiosensitivity of tumor tissue chromatin is higher than that of a normal tissue. The determination of the chromatin structure modification in an excimer laser field can be of interest in laser therapy

  4. Improving the ablation efficiency of excimer laser systems with higher repetition rates through enhanced debris removal and optimized spot pattern.

    Science.gov (United States)

    Arba-Mosquera, Samuel; Klinner, Thomas

    2014-03-01

    To evaluate the reasons for the required increased radiant exposure for higher-repetition-rate excimer lasers and determine experimentally possible compensations to achieve equivalent ablation profiles maintaining the same single-pulse energies and radiant exposures for laser repetition rates ranging from 430 to 1000 Hz. Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany. Experimental study. Poly(methyl methacrylate) (PMMA) plates were photoablated. The pulse laser energy was maintained during all experiments; the effects of the flow of the debris removal, the shot pattern for the correction, and precooling the PMMA plates were evaluated in terms of achieved ablation versus repetition rate. The mean ablation performance ranged from 88% to 100%; the variability between the profile measurements ranged from 1.4% to 6.2%. Increasing the laser repetition rate from 430 Hz to 1000 Hz reduced the mean ablation performance from 98% to 91% and worsened the variability from 1.9% to 4.3%. Increasing the flow of the debris removal, precooling the PMMA plates to -18°C, and adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the variability. Only adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the mean ablation performance. The ablation performance of higher-repetition-rate excimer lasers on PMMA improved with improvements in the debris removal systems and shot pattern. More powerful debris removal systems and smart shot patterns in terms of thermal response improved the performance of these excimer lasers. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Keratomodelling with low-intensity ultraviolet radiation of excimer laser

    International Nuclear Information System (INIS)

    Vitrishchak, I.B.; Vorontsov, V.V.; Murzin, A.G.; Polikarpov, S.S.; Soms, L.N.

    1990-01-01

    A study was made on possibility of keratomodelling with low-intensive UV-radiation of excimer laser with subablation energy density in a pulse. Model specimens of polymers and cornea tissue were used. It is shown that the range of threshold energy density in a pulse expands with increase of UV-radiation wave length and contracts with increase of pulse repetition frequency. This range appeared to be different for polymers and cornea tissue. It was revealed that cornea tissue represented a complex high-molecular bipolymer with high water content

  6. Optical and electronic properties of HWCVD and PECVD silicon films irradiated using excimer and Nd:Yag lasers

    International Nuclear Information System (INIS)

    Shaikh, M.Z.; O'Neill, K.A.; Anthony, S.; Persheyev, S.K.; Rose, M.J.

    2006-01-01

    Thin silicon film samples were deposited using HWCVD and PECVD techniques to study the influence of laser annealing on their optical and electronic properties. Samples were annealed in air using a XeCl excimer and Nd:Yag lasers. Excimer laser annealing (ELA) at 50 to 222 mJ/cm 2 increased conductivity in PECVD films by 2 to 3 orders of magnitude and in HWCVD films by 1 to 2 orders of magnitude. ELA was also seen to decrease the optical gap in PECVD films by 0.5 eV and HWCVD films by 0.15 eV. Silicon-oxygen bond content was higher in as-deposited HWCVD films than PECVD films. Hydrogen content (at.%) in PECVD films was higher than HWCVD for higher H dilution ratios. A Nd:Yag laser 3-beam interference pattern was used to produce a periodic array of crystals in both PECVD and HWCVD films

  7. Improvement of physical properties of IGZO thin films prepared by excimer laser annealing of sol–gel derived precursor films

    International Nuclear Information System (INIS)

    Tsay, Chien-Yie; Huang, Tzu-Teng

    2013-01-01

    Indium gallium zinc oxide (IGZO) transparent semiconductor thin films were prepared by KrF excimer laser annealing of sol–gel derived precursor films. Each as-coated film was dried at 150 °C in air and then annealed using excimer laser irradiation. The influence of laser irradiation energy density on surface conditions, optical transmittances, and electrical properties of laser annealed IGZO thin films were investigated, and the physical properties of the excimer laser annealed (ELA) and the thermally annealed (TA) thin films were compared. Experimental results showed that two kinds of surface morphology resulted from excimer laser annealing. Irradiation with a lower energy density (≤250 mJ cm −2 ) produced wavy and irregular surfaces, while irradiation with a higher energy density (≥350 mJ cm −2 ) produced flat and dense surfaces consisting of uniform nano-sized amorphous particles. The explanation for the differences in surface features and film quality is that using laser irradiation energy to form IGZO thin films improves the film density and removes organic constituents. The dried IGZO sol–gel films irradiated with a laser energy density of 350 mJ/cm 2 had the best physical properties of all the ELA IGZO thin films. The mean resistivity of the ELA 350 thin films (4.48 × 10 3 Ω cm) was lower than that of TA thin films (1.39 × 10 4 Ω cm), and the average optical transmittance in the visible range (90.2%) of the ELA 350 thin films was slightly higher than that of TA thin films (89.7%). - Highlights: • IGZO semiconductor films were prepared by laser annealing of sol–gel derived films. • Surface roughness and resistivity of ELA samples were affected by energy density. • The ELA 350 IGZO film exhibited the best properties among all of ELA IGZO films. • Transmittance and resistivity of ELA 350 films are greater than those of TA films

  8. Improvement of physical properties of IGZO thin films prepared by excimer laser annealing of sol–gel derived precursor films

    Energy Technology Data Exchange (ETDEWEB)

    Tsay, Chien-Yie, E-mail: cytsay@fcu.edu.tw; Huang, Tzu-Teng

    2013-06-15

    Indium gallium zinc oxide (IGZO) transparent semiconductor thin films were prepared by KrF excimer laser annealing of sol–gel derived precursor films. Each as-coated film was dried at 150 °C in air and then annealed using excimer laser irradiation. The influence of laser irradiation energy density on surface conditions, optical transmittances, and electrical properties of laser annealed IGZO thin films were investigated, and the physical properties of the excimer laser annealed (ELA) and the thermally annealed (TA) thin films were compared. Experimental results showed that two kinds of surface morphology resulted from excimer laser annealing. Irradiation with a lower energy density (≤250 mJ cm{sup −2}) produced wavy and irregular surfaces, while irradiation with a higher energy density (≥350 mJ cm{sup −2}) produced flat and dense surfaces consisting of uniform nano-sized amorphous particles. The explanation for the differences in surface features and film quality is that using laser irradiation energy to form IGZO thin films improves the film density and removes organic constituents. The dried IGZO sol–gel films irradiated with a laser energy density of 350 mJ/cm{sup 2} had the best physical properties of all the ELA IGZO thin films. The mean resistivity of the ELA 350 thin films (4.48 × 10{sup 3} Ω cm) was lower than that of TA thin films (1.39 × 10{sup 4} Ω cm), and the average optical transmittance in the visible range (90.2%) of the ELA 350 thin films was slightly higher than that of TA thin films (89.7%). - Highlights: • IGZO semiconductor films were prepared by laser annealing of sol–gel derived films. • Surface roughness and resistivity of ELA samples were affected by energy density. • The ELA 350 IGZO film exhibited the best properties among all of ELA IGZO films. • Transmittance and resistivity of ELA 350 films are greater than those of TA films.

  9. A review on laser and light-based therapies for alopecia areata.

    Science.gov (United States)

    Mlacker, Stephanie; Aldahan, Adam Souhail; Simmons, Brian James; Shah, Vidhi; McNamara, Colin Andrew; Samarkandy, Sahal; Nouri, Keyvan

    2017-04-01

    Alopecia areata is a form of non-scarring alopecia that results from a hyperactive immune response of T cells against hair follicles. Many patients with visible hair loss experience psychological and emotional distress, as a result of their cosmetic disfigurement, and frequently seek treatment. However, existing treatment methods, such as corticosteroids, topical irritants, sensitizing agents, immunosuppressants, and psoralen plus ultraviolet light A, may result in various adverse effects and often lack efficacy. Laser and light treatments offer a safe and effective alternative. This review aims to provide clinicians with a comprehensive summary of laser and light-based modalities used for the treatment of alopecia areata. Currently, the excimer laser is the most widely studied device and has shown positive results thus far. However, the development of future randomized controlled clinical trials will help determine the appropriate treatment protocols necessary, in order to achieve superior clinical outcomes.

  10. Excimer-laser-irradiation-induced effects in C60 films for photovoltaic applications

    International Nuclear Information System (INIS)

    Narayanan, K.L.; Yamaguchi, M.; Azuma, H.

    2002-01-01

    Thin films of fullerene C 60 deposited by the molecular-beam epitaxy method have been subjected to a 248 nm excimer laser for various timings. Reduction in the electrical resistance of the films and the spectral evolution of the D and G bands in the Raman spectra, due to the sharp tendency towards graphitization accompanied by an increasing level of structural disorder, are observed during laser irradiation. Based on the above results, an attempt has been carried out on these irradiated C 60 films to make a device sandwiched with n-type Si, and the photovoltaic parameters are reported as a function of the laser exposure times

  11. A review of monochromatic light devices for the treatment of alopecia areata.

    Science.gov (United States)

    Darwin, Evan; Arora, Harleen; Hirt, Penelope A; Wikramanayake, Tongyu Cao; Jimenez, Joaquin J

    2018-02-01

    There are many laser technologies that are being tested that claim to support hair regrowth for patients with alopecia areata (AA). In this paper, we will determine whether the body of evidence supports the use of devices using monochromatic light sources to treat AA. Articles were gathered from PubMed, Embase, and the Cochrane database using these keywords: lasers, excimer laser, low-level laser therapy (LLLT), low-level light therapy, alopecia, alopecia areata, and hair loss with a category modifier of English. Ten clinical trials and seven case reports/abstracts were assessed. Eight clinical trials and two case reports demonstrated hair regrowth with the 308-nm excimer laser/light in men, women, and children. One case report demonstrated hair regrowth with the ALBA 355® laser. One clinical trial and two case reports demonstrated hair regrowth with LLLT. While two case reports demonstrated hair regrowth with fractional laser therapy, one clinical trial showed no improvement. The 308-nm excimer laser is a safe and effective treatment for men, women, and children with refractory AA of the scalp and beard. Larger, double-blinded clinical trials should be conducted to compare excimer laser therapy to standard treatments. More data is needed to determine the efficacy of LLLT and fractional laser therapy in the treatment of AA.

  12. Krypton Gas for High Quality Single Wall Carbon Nanotubes Synthesis by KrF Excimer Laser Ablation

    Directory of Open Access Journals (Sweden)

    Jasim Al-Zanganawee

    2015-01-01

    Full Text Available We report for the first time the production of single wall carbon nanotubes (SWCNTs by KrF excimer laser ablation method under the krypton gas atmosphere. For the ablation experiment 450 mJ energy and 30 Hz repetition rate KrF excimer laser was used, and the target was prepared with the following composition: 0.6% Ni, 0.6% Co, and 98.8% C (atomic percentage. The ablation product was characterized by confocal Raman microspectroscopy, transmission electron microscopy (TEM, scanning electron microscopy (SEM, and thermogravimetric analysis (TGA. The SWCNTs obtained are a mixture of semiconducting and metallic types with narrow diameters distribution of 1.26 to 1.49 nm, are micrometers long, and contain low amount of graphite and amorphous carbon.

  13. LASIK for myopia and astigmatism using the SCHWIND AMARIS excimer laser: an international multicenter trial.

    Science.gov (United States)

    Arbelaez, Maria Clara; Aslanides, Ioannis M; Barraquer, Carmen; Carones, Francesco; Feuermannova, Alena; Neuhann, Tobias; Rozsival, Pavel

    2010-02-01

    To assess the efficacy, predictability, and safety of LASIK for the surgical correction of low to moderate myopia with astigmatism using the SCHWIND AMARIS excimer laser. Six international study sites enrolled 358 eyes with a manifest refraction spherical equivalent (MRSE) from -0.50 to -7.38 diopters (D) (mean sphere: -3.13+/-1.58 D) with up to -5.00 D of astigmatism (mean: -0.69+/-0.67 D). All eyes underwent treatment with the nonwavefront-guided aspheric algorithm of the SCHWIND AMARIS excimer laser. All eyes were targeted for emmetropia. Refractive outcomes and corneal higher order aberrations were analyzed pre- and postoperatively. Visual quality was assessed using photopic and mesopic contrast sensitivity. Six-month postoperative outcomes are reported. At 6 months postoperative, the MRSE for all eyes was -0.21+/-0.20 D, and 96% (343/358) of eyes had MRSE within +/-0.50 D. Uncorrected visual acuity was 20/20 or better in 98% (351/358) of eyes, and no eyes lost 2 or more lines of best spectacle-corrected visual acuity. The total corneal higher order aberrations root-mean-square increased by 0.09 microm, spherical aberration increased by 0.08 microm, and coma increased by 0.04 microm postoperatively. Photopic and mesopic contrast sensitivity did not change 6 months postoperatively. Treatment of myopia with astigmatism using the SCHWIND AMARIS excimer laser is safe, efficacious, predictable, and maintains visual quality.

  14. Influence of Selected Parameters of XeCl Excimer Laser System on Characteristics of Radiation Pulses

    International Nuclear Information System (INIS)

    Pokora, L.; Iwanejko, L.

    1998-01-01

    We present the dependences of energy and duration of radiation pulses as well as efficiency of XeCl laser on selected parameters of the laser system such as: C 2 capacitance, the separating inductance, L S , the distance between electrodes in laser's chamber, d K and also the supply voltage, U 0 , composition, and pressure of the active-medium mixture of gases. Results of numerical computations relate to a three-component mixture of gases, He-Xe-HCl, of the active medium of the excimer laser. (author)

  15. Simultaneous determinations of U-Pb age and REE abundances for zircons using AfF excimer laser ablation-ICPMS

    International Nuclear Information System (INIS)

    Iizuka, Tsuyoshi; Hirata, Takafumi

    2004-01-01

    Using a laser-ablation-inductively coupled plasma mass spectrometer (LA-ICPMS), U-Pb age and rare earth element (REE) abundances have been determined simultaneously from a single 20 μm ablation pit of zircon. The laser ablation system utilizing 193 nm wave-length ArF excimer laser produces stable and reproducible signal intensities resulted in good precisions on measurements of element concentrations and isotopic ratios. Because of the higher energy density of the deep ultra-violet laser beam, ablation fractionation between Pb and U were reduced even with the prolonged ablation, and thus accuracy of Pb-U age was improved significantly. A chicane-type ion lens system was applied to a quadrupole-based ICPMS instrument. With the chicane ion lens, higher elemental sensitivity (4 times or light mass range and 3 times for mid to heavy mass range) and lower white background ( 238 U- 206 Pb ages for Nancy standard zircon (Nancy 91500), SHRIMP calibration standard zircon (SL13) and Antarctic zircon (PMA7) obtained in this study were 1064 ± 24 Ma, 569 ± 78 Ma and 2438 ± 101 Ma (2-sigma), respectively. Relative age differences from previous reports were 0.2%, 0.4% and 3.2% respectively, demonstrative of high reliability of the method. The REE abundances in zircon samples were calibrated using a NIST 610 glass standard reference material. The resulting REE abundance data for zircons (Nancy 91500 and SL13) show good agreement with those for literature values within the analytical precision of ∼20%. The matrix effect that may occur between the synthetic glass standard and zircon crystals is obviously smaller than the precision and thus negligible for this precision levels. The data presented here demonstrate clearly that the combination of ArF excimer laser an ICPMS equipped with the chicane ion lens has a potential to become a significant tool for zircon geochemistry. (author)

  16. Structural and morphological transformations of TiO2 nanotube arrays induced by excimer laser treatment

    International Nuclear Information System (INIS)

    Hsu, Ming-Yi; Thang, Nguyen Van; Wang Chih; Leu Jihperng

    2012-01-01

    The structural and morphological transformations of TiO 2 nanotube arrays (TNAs) treated by excimer laser annealing (ELA) were investigated as a function of the laser fluence using parallel and tilted modes. Results showed that the crystallinity of the ELA-treated TNAs reached only about 50% relative to that of TNAs treated by furnace anneal at 400 °C for 1 h. The phase transformation starts from the top surface of the TNAs with surface damage resulting from short penetration depth and limited one-dimensional heat transport from the surface to the bottom under extremely short pulse duration (25 ns) of the excimer laser. When a tilted mode was used, the crystallinity of TNAs treated by ELA at 85° was increased to 90% relative to that by the furnace anneal. This can be attributed to the increased area of the laser energy interaction zone and better heat conduction to both ends of the TNAs. - Highlights: ► We examined the morphology and microstructure of TNAs treated by ELA. ► Crystallinity of parallel ELA-treated TNAs reached ∼50% of furnace anneal. ► Tilted ELA at 85o enhanced the degree of crystallization in TNAs to 90%.

  17. Micro flow-through PCR in a PMMA chip fabricated by KrF excimer laser.

    Science.gov (United States)

    Yao, Liying; Liu, Baoan; Chen, Tao; Liu, Shibing; Zuo, Tiechuan

    2005-09-01

    As the third PCR technology, micro flow-through PCR chip can amplify DNA specifically in an exponential fashion in vitro. Nowadays many academies in the world have successfully amplified DNA using their own-made flow-through PCR chip. In this paper, the ablation principle of PMMA at 248 nm excimer laser was studied, then a PMMA based flow-through PCR chip with 20 cycles was fabricated by excimer laser at 19 kv and 18 mm/min. The chip was bonded together with another cover chip at 105( composite function)C, 160 N and 20 minutes. In the end, it was integrated with electrical thermal thin films and Pt 100 temperature sensors. The temperature controllers was built standard PID digital temperature controller, the temperature control precision was +/- 0.2( composite function)C. The temperature grads between the three temperature zones were 16.5 and 22.2( composite function)C respectively, the gaps between the temperature zones could realize heat insulation.

  18. A pulsed electron injector using a metal photocathode irradiated by an excimer laser

    International Nuclear Information System (INIS)

    Kauppila, T.J.; Builta, L.A.; Crutcher, J.K.; Elliott, J.C.; Moir, D.C.

    1987-01-01

    The hot cathode of an electron gun is replaced by a metallic photocathode driven by an excimer laser. The current, current density, and emittance of the 500-kV electron beam produced by the photoelectron source are presented. In addition, the temperature of the photocathode is varied to study the possibility of a hybrid source

  19. Excimer laser processing of Ti-6Al-4V

    International Nuclear Information System (INIS)

    Folkes, J.A.; Shibata, K.

    1994-01-01

    The effect of the excimer laser on the surface of Ti-6Al-4V is reported. Particular concentration is given to surface modification for potential materials processing applications. Results showed that: (1) there is an optimum energy for smoothing titanium; (2) at this energy density increasing the number of pulses has some, but not a significant, effect on the smoothing process; and (3) relatively smooth surfaces could be achieved at higher energy densities if the sample was processed in a helium atmosphere. Other typical surface modifications and features are also reported, including the effect of different gases on the process

  20. Excimer laser coronary atherectomy in septal collaterals during retrograde recanalization of a chronic total occlusion

    Directory of Open Access Journals (Sweden)

    Bernward Lauer

    2011-09-01

    Full Text Available Management of chronic total occlusions has been refined through the development of a retrograde approach via collateral pathways. We describe the use of Excimer Laser Coronary Atherectomy in the septal collaterals. This appraoch was not yet described in the literature.

  1. Excimer laser assisted very fast exfoliation and reduction of graphite oxide at room temperature under air ambient for Supercapacitors electrode

    Science.gov (United States)

    Malek Hosseini, S. M. B.; Baizaee, S. M.; Naderi, Hamid Reza; Dare Kordi, Ali

    2018-01-01

    Excimer laser was used for reduction and exfoliation of graphite oxide (GO) at room temperature under air ambient. The prepared excimer laser reduced graphite oxide (XLRGO) is characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), nitrogen adsorption/desorption (BET method), X-ray diffraction (XRD), X-ray photoemission spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR) and UV-vis absorption techniques for surface, structural functional groups and band gap analysis. Electrochemical properties are investigated using cyclic voltammetry, galvanostatic charge-discharge, electrochemical impedance spectroscopy (EIS) and continues cyclic voltammetry (CCV) in 0.5 M Na2SO4 as electrolyte. Electrochemical investigations revealed that XLRGO electrode has enhanced supercapacitive performance including specific capacitance of 299 F/g at a scan rate of 2 mV/s. Furthermore, CCV measurement showed that XLRGO electrode kept 97.8% of its initial capacitance/capacity after 4000 cycles. The obtained results from electrochemical investigations confirm that the reduction of GO by using an excimer laser produces high-quality graphene for supercapacitor applications without the need for additional operations.

  2. Microstructures induced by excimer laser surface melting of the SiC{sub p}/Al metal matrix composite

    Energy Technology Data Exchange (ETDEWEB)

    Qian, D.S., E-mail: Daishu.qian@postgrad.manchester.ac.uk; Zhong, X.L.; Yan, Y.Z.; Hashimoto, T.; Liu, Z.

    2017-08-01

    Highlights: • Microstructural analysis of the excimer laser-melted SiC{sub p}/AA2124;. • Analytical, FEM, and SPH simulation of the laser-material interaction;. • Mechanism of the formation of the laser-induced microstructure. - Abstract: Laser surface melting (LSM) was carried out on the SiC{sub p}/Al metal matrix composite (MMC) using a KrF excimer laser with a fluence of 7 J/cm{sup 2}. The re-solidification microstructure was characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM) equipped with energy dispersive X-ray detector, and X-ray diffraction (XRD) analysis. It was found that a 2.5 μm thick melted layer was formed in the near-surface region, in which dissolution of the intermetallics and removal of the SiC particles occurred. The thermal and material response upon laser irradiation was simulated using three models, i.e. analytical model, finite element model (FEM) and smoothed-particle hydrodynamics (SPH) model. The effect of SiC particles on the LSM process, the mechanism of the SiC removal and the re-solidification microstructures in the melted layer were discussed. The simulation results were in good agreement with the experimental results and contributed to the generic understanding of the re-solidification microstructures induced by ns-pulsed lasers.

  3. Levels of interleukin-6 in tears before and after excimer laser treatment

    OpenAIRE

    Resan Mirko; Stanojević Ivan; Petković-Ćurčin Aleksandra; Pajić Bojan; Vojvodić Danilo

    2015-01-01

    Background/Aim. Immune response and consequent inflammatory process which originate on ocular surface after a trauma are mediated by cytokines. Photoablation of corneal stroma performed by excimer laser causes surgically induced trauma. Interleukin-6 (IL-6) is mostly known as a proinflammatory cytokine. However, it also has regenerative and anti-inflammatory effects. It is supposed that this cytokine is likely to play a significant role in the process of co...

  4. In-vitro ablation of fibrocartilage by XeCl excimer laser

    Science.gov (United States)

    Buchelt, Martin; Papaioannou, Thanassis; Fishbein, Michael C.; Peters, Werner; Beeder, Clain; Grundfest, Warren S.

    1991-07-01

    A 308 nm excimer laser was employed for ablation of human fibrocartilage. Experiments were conducted in vitro. The tissue response was investigated with respect to dosimetry (ablation rate versus radiant exposure) and thermal effect (thermographic analysis). Irradiation was performed via a 600 um fiber, with radiant exposures ranging between 20mj/mm2 and 80mj/mm2, at 20Hz. The ablation rates were found to range from 3um/pulse to 80um/pulse depending on the radiant exposure and/or the applied pressure on the delivery system. Thermographic analysis, during ablation, revealed maximum average temperatures of about 65 degree(s)C. Similar measurements performed, for the purpose of comparison, with a CW Nd:YAG and a CW CO2 laser showed higher values, of the order of 200 degree(s)C.

  5. Excimer laser assisted re-oxidation of BaTiO3 thin films on Ni metal foils

    International Nuclear Information System (INIS)

    Bharadwaja, S. S. N.; Ko, S. W.; Qu, W.; Clark, T.; Rajashekhar, A.; Motyka, M.; Podraza, N.; Randall, C. A.; Trolier-McKinstry, S.

    2016-01-01

    Excimer laser assisted re-oxidation for reduced, crystallized BaTiO 3 thin films on Ni-foils was investigated. It was found that the BaTiO 3 can be re-oxidized at an oxygen partial pressure of ∼50 mTorr and substrate temperature of 350 °C without forming a NiO x interface layer between the film and base metal foil. The dielectric permittivity of re-oxidized films was >1000 with loss tangent values <2% at 100 Hz, 30 mV rms excitation signal. Electron Energy Loss Spectroscopy indicated that BaTiO 3 thin films can be re-oxidized to an oxygen stoichiometry close to ∼3 (e.g., stoichiometric). High resolution cross sectional transmission electron microscopy showed no evidence of NiO x formation between the BaTiO 3 and the Ni foil upon excimer laser re-oxidation. Spectroscopic ellipsometry studies on laser re-oxidized [001] C and [111] C BaTiO 3 single crystals indicate that the re-oxidation of BaTiO 3 single crystals is augmented by photo-excitation of the ozone, as well as laser pulse induced temperature and local stress gradients

  6. Excimer laser crystallization of InGaZnO4 on SiO2 substrate

    NARCIS (Netherlands)

    Chen, T.; Wu, M.Y.; Ishihara, R.; Nomura, K.; Kamiya, T.; Hosono, H.; Beenakker, C.I.M.

    2011-01-01

    In this paper, we were able to crystallize InGaZnO4 (IGZO) by excimer laser on SiO2 substrate. It was observed that uniform [0001] textured polycrystalline IGZO film has been obtained without any grain boundaries and oxygen vacancies on SiO2 substrate. This process is very promising in fabricating

  7. ArF Excimer Laser-induced Deposition of Ag/C Nanocomposite Thin Films in the Presence of n-Hexane

    Czech Academy of Sciences Publication Activity Database

    Gondal, M.A.; Fajgar, Radek; Chang, X.; Shen, K.; Xu, Q.

    2014-01-01

    Roč. 311, AUG 30 (2014), s. 95-100 ISSN 0169-4332 Grant - others:NNSFCH(CN) 51172044; NSFJP(CN) BK2011617; KFUPM(CN) RG 1311-1 Institutional support: RVO:67985858 Keywords : ArF excimer laser * nanocomposite * laser deposition Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 2.711, year: 2014

  8. Original papers A study on efficacy of 308 nm excimer light therapy in alopecia areata

    Directory of Open Access Journals (Sweden)

    Zo Nun Sanga

    2015-06-01

    Full Text Available Introduction. Alopecia areata (AA is an autoimmune condition characterized by T-cell-mediated attack on hair follicles. Objective. Evaluation of efficacy of 308 nm excimer light in the treatment of alopecia areata. Material and methods. Patches of AA were treated twice weekly, but not on 2 consecutive days, with UVB excimer 308 nm light. In all patients, half of the AA patch was irradiated and the other half was spared, covered with a black rubber shield and taken as a control. Therapy was started with an initial dose of 300 mJ/cm 2 , with an incremental dose of 100 mJ/cm 2 at every sitting until fine erythema appeared. Results. At the end of the treatment, one patient (3.33% at the test site showed > 50% hair regrowth vs. none at the control site. After a 2-month post-treatment period, successful hair regrowth (grades 3 and 4 was seen in 12 patients at test sites and in 2 patients at control sites. The differences were statistically significant (p < 0.05. After 4 months successful hair regrowth (grades 3 and 4 was seen in 16 patients at test sites and in 5 patients at control sites. The differences were statistically significant (p 0.05. Conclusions. Excimer light has the potential to stimulate hair regrowth in patches of alopecia areata.

  9. Endobronchial Forceps-Assisted and Excimer Laser-Assisted Inferior Vena Cava Filter Removal: The Data, Where We Are, and How It Is Done.

    Science.gov (United States)

    Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William

    2018-06-01

    The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Hydrophilicity and morphological investigation of polycarbonate irradiated by ArF excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Jaleh, B. [Bu-Ali-Sina University, Physics Department, Postal Code 65174, Hamedan (Iran, Islamic Republic of)], E-mail: jaleh@basu.ac.ir; Parvin, P. [Amir Kabir University of Technology, Physics Department, P.O. Box: 15875-4413, Tehran (Iran, Islamic Republic of); Laser Research Center, AEOI, P.O. Box: 11365-8486, Tehran (Iran, Islamic Republic of); Sheikh, N. [Nuclear Science and Technology Research Institute, Radiation Applications Research School, Tehran (Iran, Islamic Republic of); Zamanipour, Z. [Laser Research Center, AEOI, P.O. Box: 11365-8486, Tehran (Iran, Islamic Republic of); Sajad, B. [Azzahra University, Physics Department, Tehran (Iran, Islamic Republic of)

    2007-12-15

    Lasers are used to modify polymeric materials. In this work, a number of polycarbonate (PC) pieces were exposed by ArF excimer laser, 193 nm, at various UV doses from 10 to 100 J/cm{sup 2} with 50-500 mJ/pulse at 10 Hz pulse repetition rate. Morphology of PC has been investigated by scanning electron microscope (SEM) at three regimes pre-ablation, slow and fast ablation. SEM identifies that the conical defects are created on the polymer surface to grow opposite to the direction of laser irradiation. It increases the superficial absorptivity of the material dependent on the ArF laser induced conical microstructure geometry. The contact angle measurement was performed here, in order to determine the hydrophilicity of the irradiated polymer at various coherent doses. It is shown that the contact angle of PC samples which are exposed to the ArF laser significantly alters with UV dose below 7 J/cm{sup 2}.

  11. Measurements of barium photocathode quantum yields at four excimer laser wavelengths

    International Nuclear Information System (INIS)

    Van Loy, M.D.; Young, A.T.; Leung, K.N.

    1992-06-01

    The electron quantum yields from barium cathodes excited by excimer laser radiation at 193, 248, 308, and 351 nm have been determined. Experiments with different cathode surface preparation techniques reveal that deposition of barium film a few microns thick on a clean copper surface under moderate vacuum conditions achieves relatively high quantum efficiencies. Quantum yields measured from surfaces prepared in this manner are 2.3 x 10 -3 at 193 nm, 7.6 x 10 - 4 at 248 nm, 6.1 x 10 -4 at 308 nm, and 4.0 x 10 -4 at 351 nm. Other preparation techniques, such as laser cleaning of a solid barium surface, produced quantum yields that were at least an order of magnitude lower than these values

  12. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    International Nuclear Information System (INIS)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio; Golino, Luca; Casafina, Alfredo; Schiano, Vittorio; Gabrielli, Gabriele; Ettori, Federica; Chizzola, Giuliano; Bernardi, Guglielmo; Spedicato, Leonardo; Armigliato, Pietro; Spampanato, Carmine; Furegato, Martina

    2015-01-01

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  13. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio [Montevergine Clinic, Mercogliano (Italy); Golino, Luca, E-mail: lucagolino.jazz@alice.it [Montevergine Clinic, Mercogliano (Italy); Moriggia-Pelascini Hospital, Gravedona, Como (Italy); Casafina, Alfredo; Schiano, Vittorio [Montevergine Clinic, Mercogliano (Italy); Gabrielli, Gabriele [University Hospital Ospedali Riuniti, Ancona (Italy); Ettori, Federica; Chizzola, Giuliano [Spedali Civili University Hospital, Brescia (Italy); Bernardi, Guglielmo; Spedicato, Leonardo [University Hospital S. Maria Misericordia, Udine (Italy); Armigliato, Pietro [Istituto Italiano Ricerche Mediche, Verona (Italy); Spampanato, Carmine [Telethon Institute of Genetics and Medicine (TIGEM), Naples (Italy); Furegato, Martina [Istituto Italiano Ricerche Mediche, Verona (Italy)

    2015-04-15

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  14. Effect of laser-plasma X-ray irradiation on crystallization of amorphous silicon film by excimer laser annealing

    International Nuclear Information System (INIS)

    Matsuo, Naoto; Uejukkoku, Kazuya; Heya, Akira; Takanashi, Yasuyuki; Amano, Sho; Miyamoto, Shuji; Mochizuki, Takayasu

    2007-01-01

    The effect of laser plasma soft X-ray (LPX) irradiation on crystallization by excimer laser annealing (ELA) was investigated at low ELA energy densities. The crystalline fraction at energy densities of 50 and 60 mJ/cm 2 for LPX followed by ELA is nearly equal to that at 80 to 100 mJ/cm 2 for the ELA method with non-LPX irradiation. The results obtained indicate that LPX irradiation before ELA reduces the critical energy density for the start of crystallization. The combined method of LPX irradiation and ELA will enable us to realize a low-temperature process for ELA crystallization. (author)

  15. Pulse repetition frequency effects in a high average power x-ray preionized excimer laser

    International Nuclear Information System (INIS)

    Fontaine, B.; Forestier, B.; Delaporte, P.; Canarelli, P.

    1989-01-01

    Experimental study of waves damping in a high repetition rate excimer laser is undertaken. Excitation of laser active medium in a subsonic loop is achieved by means of a classical discharge, through transfer capacitors. The discharge stability is controlled by a wire ion plasma (w.i.p.) X-rays gun. The strong acoustic waves induced by the active medium excitation may lead to a decrease, at high PRF, of the energy per pulse. First results of the influence of a damping of induced density perturbations between two successive pulses are presented

  16. Excimer laser correction of hyperopia, hyperopic and mixed astigmatism: past, present, and future.

    Science.gov (United States)

    Lukenda, Adrian; Martinović, Zeljka Karaman; Kalauz, Miro

    2012-06-01

    The broad acceptance of "spot scanning" or "flying spot" excimer lasers in the last decade has enabled the domination of corneal ablative laser surgery over other refractive surgical procedures for the correction of hyperopia, hyperopic and mixed astigmatism. This review outlines the most important reasons why the ablative laser correction of hyperopia, hyperopic and mixed astigmatism for many years lagged behind that of myopia. Most of today's scanning laser systems, used in the LASIK and PRK procedures, can safely and effectively perform low, moderate and high hyperopic and hyperopic astigmatic corrections. The introduction of these laser platforms has also significantly improved the long term refractive stability of hyperopic treatments. In the future, further improvements in femtosecond and nanosecond technology, eye-tracker systems, and the development of new customized algorithms, such as the ray-tracing method, could additionally increase the upper limit for the safe and predictable corneal ablative laser correction ofhyperopia, hyperopic and mixed astigmatism.

  17. Levels of interleukin-6 in tears before and after excimer laser treatment

    Directory of Open Access Journals (Sweden)

    Resan Mirko

    2015-01-01

    Full Text Available Background/Aim. Immune response and consequent inflammatory process which originate on ocular surface after a trauma are mediated by cytokines. Photoablation of corneal stroma performed by excimer laser causes surgically induced trauma. Interleukin-6 (IL-6 is mostly known as a proinflammatory cytokine. However, it also has regenerative and anti-inflammatory effects. It is supposed that this cytokine is likely to play a significant role in the process of corneal wound healing response after photoablation of stroma carried out by laser in situ keratomileusis (LASIK or photorefractive keratectomy (PRK methods. The aim of this study was to determine and compare the levels of IL-6 in tears before and after treatment with LASIK and PRK methods. Methods. The study included 68 shortsighted eyes up to -3.0 diopter sphere, i.e. 198 samples of tears (per three samples taken from each of the eyes, divided into two groups according to the kind of excimer laser intervention performed: the group 1 - eyes treated by LASIK method (n = 31, and the group 2 - eyes treated by the PRK method (n = 37. The samples of tears were taken from each eye at the following time points: before excimer laser treatment (0 h, the control group, 1 h after the treatment (1 h and 24 h after the treatment (24 h. The patients did not use anti-inflammatory therapy 24 h after the intervention. Tear samples were collected using microsurgical sponge. Level of IL-6 in tear fluid was determined by the flow cytometry method, applying a commercial test kit which allowed cytokine detection from a small sample volume. Results. The values of IL-6 were detectable in 16% of samples before LASIK treatment and in 30% of samples before PRK treatment. One h after the treatment IL-6 was detectable in 29% of samples for the LASIK group and 43% of samples for the PRK group, and 24 h after the treatment it was detectable in 19% of samples for the LASIK group and in 57% of samples for the PRK group. When we

  18. Levels of interleukin-6 in tears before and after excimer laser treatment.

    Science.gov (United States)

    Resan, Mirko; Stanojević, Ivan; Petković, Aleksandra; Pajić, Bojan; Vojvodić, Danilo

    2015-04-01

    Immune response and consequent inflammatory process which originate on ocular surface after a trauma are mediated by cytokines. Photoablation of corneal stroma performed by excimer laser causes surgically induced trauma. Interleukin-6 (IL-6) is mostly known as a proinflammatory cytokine. However, it also has regenerative and anti-inflammatory effects. It is supposed that this cytokine is likely to play a significant role in the process of corneal wound healing response after photoablation of stroma carried out by laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) methods. The aim of this study was to determine and compare the levels of IL-6 in tears before and after treatment with LASIK and PRK methods. The study included 68 shortsighted eyes up to -3.0 diopter sphere, i.e. 198 samples of tears (per three samples taken from each of the eyes), divided into two groups according to the kind of excimer laser intervention performed: the group 1--eyes treated by LASIK method (n=31), and the group 2--eyes treated by the PRK method (n=37). The samples of tears were taken from each eye at the following time points: before excimer laser treatment (0 h, the control group), 1 h after the treatment (1 h) and 24 h after the treatment (24 h). The patients did not use anti-inflammatory therapy 24 h after the intervention. Tear samples were collected using microsurgical sponge. Level of IL-6 in tear fluid was determined by the flow cytometry method, applying a commercial test kit which allowed cytokine detection from a small sample volume. Results. The values of IL-6 were detectable in 16% of samples before LASIK treatment and in 30% of samples before PRK treatment. One h after the treatment IL-6 was detectable in 29% of samples for the LASIK group and 43% of samples for the PRK group, and 24 h after the treatment it was detectable in 19% of samples for the LASIK group and in 57% of samples for the PRK group. When we analyzed the dynamics of IL76 production

  19. Update on excimer laser photorefractive keratectomy (PRK) at Cedars-Sinai Medical Center: two-year experience

    Science.gov (United States)

    Maguen, Ezra I.; Salz, James J.; Warren, Cathy; Papaioannou, Thanassis; Nesburn, Anthony B.; Macy, Jonathan I.; Hofbauer, John; Grundfest, Warren S.

    1993-06-01

    Our two year experience with excimer laser photorefractive keratectomy for the correction of myopia on 160 eyes of 128 patients is described. All eyes were treated with a VISX Twenty- Twenty excimer laser, with the following parameters: radiant exposure 160 mJ/cm2, frequency 5 Hz, ablation zone diameter 5.0 to 5.5 mm, and stromal ablation rate 0.18 to 0.33 (mu) /pulse. A suction fixation ring was used in all cases either with nitrogen flow (79 eyes) or without nitrogen flow (81 eyes) across the cornea. Follow-up ranged from one month (152 eyes) to 24 months (12 eyes). The results are stable between 3 and 24 months with less than 0.25 D change in the mean postoperative spherical equivalents. In eyes with a follow-up of 6 to 24 months, 77% to 100% were 20/40 or better uncorrected, and 84% to 92% were corrected to within +/- 1 D of emmetropia. Further follow-up is needed to assess the long term safety and efficacy of the procedure.

  20. Surface morphologies of excimer-laser annealed BF2+ implanted Si diodes

    International Nuclear Information System (INIS)

    Burtsev, A.; Schut, H.; Nanver, L.K.; Veen, A. van; Slabbekoorn, J.; Scholtes, T.L.M.

    2004-01-01

    Laser-induced surface roughness and damage formation in ultra-shallow n + -p and p + -n junctions, formed by low energy (5 keV) As + and BF 2 + implantations in Si, respectively, with a dose of 1 x 10 15 cm -2 have been investigated by atomic force microscopy (AFM) and Positron Annihilation Doppler Broadening (PADB) technique. The Si surface roughness is found to increase with laser energy density, and reaches a value of 3.5 nm after excimer-laser annealing (ELA) at 1100 mJ/cm 2 . However, anomalous behavior is witnessed for BF 2 + -implanted Si sample at 800 mJ/cm 2 , at which energy very high surface protrusions up to 9 nm high are observed. By PADB this behavior is correlated to extensive deep microcavity formation in the Si whereby the volatile F 2 fraction can accumulate and evaporate/out-diffuse, leading to Si surface roughening. The consequences for the diode characteristics and contact resistivity are examined

  1. An experimental study on laser drilling and cutting of composite materials for the aerospace industry using excimer and CO2 sources

    Science.gov (United States)

    dell'Erba, M.; Galantucci, L. M.; Miglietta, S.

    This paper reports on the results of research which investigated the potential for the application of an excimer laser in the field of composite material drilling and cutting, by comparing this technology with that using CO2 sources. In particular, the scope of the work was to check whether the interaction between excimer lasers and composite materials, whose characteristic feature is the absence of thermal transfer, could yield better results than those obtainable with CO2 sources once heat transfer-induced difficulties had been eliminated. The materials selected for the experiments were multilayer composites having an epoxy resin matrix (65 percent in volume), with aramid fiber (Kevlar), carbon fiber and glass fiber as reinforcing materials, all of considerable interest for the aerospace industry. Optimal operational parameters were identified in relation to each source with a view to obtaining undersize holes or through cuts exhibiting severed areas of good quality. A comparison between the two types of processing carried out show that rims processed by excimer lasers are of better quality - particularly so with Kevlar - whereas the ablation rate is undoubtedly rather low compared with the CO2 technology.

  2. Effect of KrF excimer laser irradiation on the surface changes and photoelectric properties of ZnO single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Yong [Institute of Laser Engineering, Beijing University of Technology, Beijing 100124 (China); Beijing Engineering Research Center of 3D Printing for Digital Medical Health, Beijing International Cooperation Base of 3D Printing for Digital MedicalHealth, Beijing University of Technology, Beijing 100124 (China); Zhao, Yan [Institute of Laser Engineering, Beijing University of Technology, Beijing 100124 (China); Jiang, Yijian, E-mail: yjjiang@bjut.edu.cn [Institute of Laser Engineering, Beijing University of Technology, Beijing 100124 (China); Beijing Engineering Research Center of 3D Printing for Digital Medical Health, Beijing International Cooperation Base of 3D Printing for Digital MedicalHealth, Beijing University of Technology, Beijing 100124 (China)

    2016-06-25

    In this paper, the effect of KrF pulsed excimer laser irradiation on the structural, surface morphology, photoluminescence and electrical properties of ZnO single crystal was investigated. Compared to the as-grown sample, at an irradiation energy density of 257 mJ/cm{sup 2}, the ZnO single crystal exhibits a series of phenomenon: XRD and Raman results show that the crystallization of ZnO quality change slightly, resistivity is decreased by two orders of magnitude, carrier concentration is increased by one order of magnitude. After laser irradiation, the surface shows some strip lines and no cracks. Formula calculation and simulation results show that the stripes are not caused by surface melting. We speculate that these stripes are caused by the precipitation of ZnO material inside to the surface. Due to the reduction of oxygen vacancies, UV emission has been enhanced and visible emission has been declined after irradiation. After the laser irradiation, the visible light of ZnO surface can be regulated. The experimental results show that KrF laser irradiation could effectively improve the optical and electrical properties of ZnO single crystal, which is important for the application of high performance of emitting optoelectronic devices. - Highlights: • After laser irradiation, the surface shows some strip lines and no cracks. • The visible light of as-irradiated ZnO surface can be regulated to four colors. • The electrical properties of as-irradiated ZnO has been improved greatly.

  3. Evaluation and diffusion of excimer laser treatment of myopia in the United States and in the Netherlands

    NARCIS (Netherlands)

    Vondeling, H.; Rosendal, H.; Banta, D.

    1995-01-01

    Excimer laser photorefractive keratectomy (PRK) is an experimental treatment to correct myopia (short-sightedness) that is diffusing into use without convincing evidence of safety and efficacy. It has been claimed that PRK may render conventional methods of correcting myopia, such as wearing glasses

  4. Excimer laser-assisted anterior lamellar keratoplasty for keratoconus, corneal problems after laser in situ keratomileusis, and corneal stromal opacities.

    Science.gov (United States)

    Bilgihan, Kamil; Ozdek, Sengül C; Sari, Ayça; Hasanreisoğlu, Berati

    2006-08-01

    To evaluate excimer laser-assisted anterior lamellar keratoplasty to augment thin corneas as in keratoconus ( .05). This technique presents a different modality for the treatment of keratoconus, post-LASIK corneal problems, and other corneal stromal opacities with anterior lamellar keratoplasty. Additional studies with more patients and longer follow-up will help determine the role of this technique as a substitute for penetrating keratoplasty in these patients.

  5. Perspectives and advantages of the use of excimer laser annealing for MOS technology

    International Nuclear Information System (INIS)

    Privitera, V.; Alippi, P.; Camalleri, M.

    2006-01-01

    The integration of excimer laser annealing (ELA) into the MOS device technology has been studied and evaluated within the frame of the IST project FLASH (Fundamentals and applications of laser processing for highly innovative MOS technology), funded by the European Commission. The final aim of the project was to demonstrate that ELA can be applied as a reliable, effective and advantageous process in the context of semiconductor device fabrication. Some of the results of this activity are summarised, relative to the experimental characterization and theoretical modelling. The electrical characterization of the transistor fabricated by ELA is also presented, showing a device yield of 90% on wafer

  6. Advanced excimer laser technologies enable green semiconductor manufacturing

    Science.gov (United States)

    Fukuda, Hitomi; Yoo, Youngsun; Minegishi, Yuji; Hisanaga, Naoto; Enami, Tatsuo

    2014-03-01

    "Green" has fast become an important and pervasive topic throughout many industries worldwide. Many companies, especially in the manufacturing industries, have taken steps to integrate green initiatives into their high-level corporate strategies. Governments have also been active in implementing various initiatives designed to increase corporate responsibility and accountability towards environmental issues. In the semiconductor manufacturing industry, there are growing concerns over future environmental impact as enormous fabs expand and new generation of equipments become larger and more powerful. To address these concerns, Gigaphoton has implemented various green initiatives for many years under the EcoPhoton™ program. The objective of this program is to drive innovations in technology and services that enable manufacturers to significantly reduce both the financial and environmental "green cost" of laser operations in high-volume manufacturing environment (HVM) - primarily focusing on electricity, gas and heat management costs. One example of such innovation is Gigaphoton's Injection-Lock system, which reduces electricity and gas utilization costs of the laser by up to 50%. Furthermore, to support the industry's transition from 300mm to the next generation 450mm wafers, technologies are being developed to create lasers that offer double the output power from 60W to 120W, but reducing electricity and gas consumption by another 50%. This means that the efficiency of lasers can be improve by up to 4 times in 450mm wafer production environments. Other future innovations include the introduction of totally Heliumfree Excimer lasers that utilize Nitrogen gas as its replacement for optical module purging. This paper discusses these and other innovations by Gigaphoton to enable green manufacturing.

  7. Deposition of high Tc superconductor thin films by pulsed excimer laser ablation and their post-synthesis processing

    International Nuclear Information System (INIS)

    Ogale, S.B.

    1992-01-01

    This paper describes the use of pulsed excimer laser ablation technique for deposition of high quality superconductor thin films on different substrate materials such as Y stabilized ZrO 2 , SrTiO 3 , LiNbO 3 , Silicon and Stainless Steels, and dopant incorporation during the film depositions. Processing of deposited films using ion and laser beams for realisation of device features are presented. 28 refs., 16 figs

  8. Preparation of PZT thin films on YBCO electrodes by KrF excimer laser ablation technique

    International Nuclear Information System (INIS)

    Kurogi, H.; Yamagata, Y.; Ebihara, K.

    1998-01-01

    Pb(Zr X Ti 1-X )O 3 (PZT) films have excellent ferroelectric, optical, piezoelectric, and pyroelectric properties. We prepared PZT thin films by the excimer laser ablation technique. A pulsed KrF excimer laser (Lambda Physik LPX305icc, pulse duration of 25 ns, λ=248 nm, 850 mJ Max.) was used to ablate the bulk targets. We investigated the influence of bottom electrode materials on the characteristics of the PZT thin films prepared on Pt and YBCO underlayers. The X-ray diffraction (XRD) patterns showed that the PZT films prepared with a laser fluence of 2 Jcm -2 on YBCO/MgO(100) substrate at a wide temperature range of 550-680 C have a perovskite (001) structure. At the same laser fluence, the PZT films prepared on Pt/MgO(100) substrate have a perovskite (001) structure only at 650 C. The polarization-electric field (P-E) characteristics and fatigue properties of PZT thin films were measured by the Sawyer-Tower circuit. The remnant polarization and coercive field have been found to be P r =15 μC cm -2 , 30 μC cm -2 and E c =200 kV cm -1 , 100 kV cm -1 for Au/PZT/Pt/MgO and Au/PZT/YBCO/MgO correspondingly. The remnant polarization of Au/PZT/YBCO/MgO thin film was reduced to one-half after about 10 8 cycles of switching. (orig.)

  9. Pustular Palmoplantar Psoriasis Successfully Treated with Nb-UVB Monochromatic Excimer Light: A Case-Report

    Directory of Open Access Journals (Sweden)

    Serena Gianfaldoni

    2017-07-01

    Full Text Available Barber’s palmoplantar pustulosis (PPP is a form of localised pustular psoriasis, affecting the palmar and plantar surfaces. It is a chronic disease, with a deep impact on the patients’ quality of life. The Authors discuss a case of Baber Psoriasis successfully treated with monochromatic excimer light.

  10. Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platform

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2012-06-01

    Full Text Available Anastasios John KanellopoulosDepartment of Ophthalmology, New York University Medical School, New York, NY, and LaserVision.gr Eye Institute, Athens, GreeceBackground: The purpose of this study was to evaluate the safety and efficacy of topography-guided ablation using the WaveLight 400 Hz excimer laser in laser-assisted in situ keratomileusis (LASIK for hyperopia and/or hyperopic astigmatism.Methods: We prospectively evaluated 208 consecutive LASIK cases for hyperopia with or without astigmatism using the topography-guided platform of the 400 Hz Eye-Q excimer system. The mean preoperative sphere value was +3.04 ± 1.75 (range 0.75–7.25 diopters (D and the mean cylinder value was –1.24 ± 1.41 (–4.75–0 D. Flaps were created either with Intralase FS60 (AMO, Irvine, CA or FS200 (Alcon, Fort Worth, TX femtosecond lasers. Parameters evaluated included age, preoperative and postoperative refractive error, uncorrected distance visual acuity, corrected distance visual acuity, flap diameter and thickness, topographic changes, higher order aberration changes, and low contrast sensitivity. These measurements were repeated postoperatively at regular intervals for at least 24 months.Results: Two hundred and two eyes were available for follow-up at 24 months. Uncorrected distance visual acuity improved from 5.5/10 to 9.2/10. At 24 (8–37 months, 75.5% of the eyes were in the ±0.50 D range and 94.4% were in the ±1.00 D range of the refractive goal. Postoperatively, the mean sphere value was –0.39 ± 0.3 and the cylinder value was –0.35 ± 0.25. Topographic evidence showed that ablation was made in the visual axis and not in the center of the cornea, thus correlating with the angle kappa. No significant complications were encountered in this small group of patients.Conclusion: Hyperopic LASIK utilizing the topography-guided platform of the 400 Hz Eye-Q Allegretto excimer and a femtosecond laser flap appears to be safe and effective for

  11. Boron distribution in silicon after multiple pulse excimer laser annealing

    International Nuclear Information System (INIS)

    Monakhov, E.V.; Svensson, B.G.; Linnarsson, M.K.; La Magna, A.; Italia, M.; Privitera, V.; Fortunato, G.; Cuscuna, M.; Mariucci, L.

    2005-01-01

    We have studied B redistribution in Si after excimer laser annealing (ELA) with multiple laser pulses. B was implanted with energies of 1 and 10 keV and doses of 1x10 14 and 1x10 15 cm -2 . ELA with the number of pulses from 1 to 100 was performed at room temperature and 450 deg. C in vacuum. Irrespective of the implantation parameters and the ELA conditions used, a pile-up in the B concentration is observed near the maximum melting depth after ten pulses of ELA. Moreover, a detailed study has revealed that B accumulates at the maximum melt depth gradually with the number of ELA pulses. Besides, an increase in the carrier concentration is observed at the maximum melt depth, suggesting electrical activity of the accumulated B. Formation of Si-B complexes and vacancy accumulation during multiple ELA are discussed as possible mechanisms for the B build-up

  12. Improved model for the angular dependence of excimer laser ablation rates in polymer materials

    Science.gov (United States)

    Pedder, J. E. A.; Holmes, A. S.; Dyer, P. E.

    2009-10-01

    Measurements of the angle-dependent ablation rates of polymers that have applications in microdevice fabrication are reported. A simple model based on Beer's law, including plume absorption, is shown to give good agreement with the experimental findings for polycarbonate and SU8, ablated using the 193 and 248 nm excimer lasers, respectively. The modeling forms a useful tool for designing masks needed to fabricate complex surface relief by ablation.

  13. The Improvement of Electrical Characteristics of Pt/Ti Ohmic Contacts to Ga-Doped ZnO by Homogenized KrF Pulsed Excimer Laser Treatment

    Science.gov (United States)

    Oh, Min-Suk

    2018-04-01

    We investigated the effect of KrF excimer laser surface treatment on Pt/Ti ohmic contacts to Ga-doped n-ZnO ( N d = 4.3 × 1017 cm-3). The treatment of the n-ZnO surfaces by laser irradiation greatly improved the electrical characteristics of the metal contacts. The Pt/Ti ohmic layer on the laser-irradiated n-ZnO showed specific contact resistances of 2.5 × 10-4 ˜ 4.8 × 10-4 Ω cm2 depending on the laser energy density and gas ambient, which were about two orders of magnitude lower than that of the as-grown sample, 8.4 × 10-2 Ω cm2. X-ray photoelectron spectroscopy and photoluminescence measurements showed that the KrF excimer laser treatments increased the electron concentration near the surface region of the Ga-doped n-ZnO due to the preferential evaporation of oxygen atoms from the ZnO surface by the laser-induced dissociation of Zn-O bonds.

  14. SF{sub 6} decomposition and layer formation due to excimer laser photoablation of SiO{sub 2} surface at gas-solid system

    Energy Technology Data Exchange (ETDEWEB)

    Sajad, Batool [Physics Department, Amirkabir University, PO Box 15875-4413, Tehran (Iran, Islamic Republic of); Parvin, Parviz [Physics Department, Amirkabir University, PO Box 15875-4413, Tehran (Iran, Islamic Republic of); Bassam, Mohamad Amin [Excimer Laser Lab, Emam Hussain University, PO Box 16575-4347, Tehrann (Iran, Islamic Republic of)

    2004-12-21

    In this work, the effect of an excimer laser has been studied for presenting a method for SF{sub 6} decomposition and simultaneous formation of a SiF{sub 2} layer on amorphous SiO{sub 2}. Though the excimer laser did not establish a gas phase photodissociation, we have shown that UV photoablation leads strongly to molecular decomposition in the SF{sub 6}-SiO{sub 2} system. Moreover, the dependence of the decomposition process on the exposure parameters such as the wavelength and intensity as well as the gas pressure and the focal point distance from the gas-solid interface has been investigated.

  15. Optical coherence tomography following percutaneous coronary intervention with Excimer laser coronary atherectomy

    Energy Technology Data Exchange (ETDEWEB)

    Rawlins, John, E-mail: john.rawlins@doctors.net.uk; Talwar, Suneel; Green, Mark; O’Kane, Peter

    2014-01-15

    The indications for Excimer laser coronary atherectomy (ELCA) have been refined in modern interventional practice. With the expanding role for optical coherence tomography (OCT) providing high-resolution intra-coronary imaging, this article examines the appearance of the coronary lumen after ELCA. Each indication for ELCA is discussed and illustrated with a clinical case, followed by detailed analysis of the OCT imaging pre and post ELCA. The aim of the article is to provide information to interventional cardiologists to facilitate decision making during PCI, when ELCA has been used as part of the interventional strategy.

  16. A 223-nm KrCl excimer laser on a He-Kr-HCl mixture

    International Nuclear Information System (INIS)

    Razhev, A M; Zhupikov, A A; Kargapol'tsev, E S

    2004-01-01

    The results of experimental studies of the parameters of a 223-nm electric-discharge KrCl excimer laser on a He-Kr-HCl mixture depending on the excitation conditions and the composition of the active gaseous medium are presented. To achieve the maximum values of the output energy and the efficiency of the KrCl laser on mixtures with buffer gaseous helium, an excitation system was used that included a circuit with an LC inverter with a high-voltage switch based on an RU-65 spark gap. An output energy of 320 mJ with an efficiency of 0.5% relative to the energy stored in the capacitors is obtained in a KrCl laser with an active medium based on the buffer He gas at a charging voltage of 30 kV. Radiation pulses with a duration of 22±1 ns and a pulse power of 15 MW are obtained. (lasers)

  17. Preparation of PZT thin films on YBCO electrodes by KrF excimer laser ablation technique

    Energy Technology Data Exchange (ETDEWEB)

    Kurogi, H; Yamagata, Y; Ebihara, K [Kumamoto Univ. (Japan). Dept. of Electr. Eng. and Comput. Sci.; Inoue, N [Kyushu Electric Power Co., Inc., Suizenji, 1-6-36, Kumamoto 862 (Japan)

    1998-03-01

    Pb(Zr{sub X}Ti{sub 1-X})O{sub 3} (PZT) films have excellent ferroelectric, optical, piezoelectric, and pyroelectric properties. We prepared PZT thin films by the excimer laser ablation technique. A pulsed KrF excimer laser (Lambda Physik LPX305icc, pulse duration of 25 ns, {lambda}=248 nm, 850 mJ Max.) was used to ablate the bulk targets. We investigated the influence of bottom electrode materials on the characteristics of the PZT thin films prepared on Pt and YBCO underlayers. The X-ray diffraction (XRD) patterns showed that the PZT films prepared with a laser fluence of 2 Jcm{sup -2} on YBCO/MgO(100) substrate at a wide temperature range of 550-680 C have a perovskite (001) structure. At the same laser fluence, the PZT films prepared on Pt/MgO(100) substrate have a perovskite (001) structure only at 650 C. The polarization-electric field (P-E) characteristics and fatigue properties of PZT thin films were measured by the Sawyer-Tower circuit. The remnant polarization and coercive field have been found to be P{sub r}=15 {mu}C cm{sup -2}, 30 {mu}C cm{sup -2} and E{sub c}=200 kV cm{sup -1}, 100 kV cm{sup -1} for Au/PZT/Pt/MgO and Au/PZT/YBCO/MgO correspondingly. The remnant polarization of Au/PZT/YBCO/MgO thin film was reduced to one-half after about 10{sup 8} cycles of switching. (orig.) 7 refs.

  18. DNA damage in cultured human skin fibroblasts exposed to excimer laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    Rimoldi, D.; Miller, A.C.; Freeman, S.E.; Samid, D. (Department of Pathology, Uniformed Services University of the Health Sciences, Bethesda, MD (USA))

    1991-06-01

    Ultraviolet excimer lasers are being considered for use in a variety of refractive and therapeutic procedures, the long-term biologic consequences of which are unknown. The effect of sublethal doses of 193-nm laser radiation on cellular DNA was examined in cultured human skin fibroblasts. In contrast to 248 nm, treatments with the 193-nm laser radiation below 70 J/m2 did not cause significant pyrimidine dimer formation in the skin cells. This was indicated by the lack of excision repair activities (unscheduled DNA synthesis assay), and further demonstrated by direct analysis of pyrimidine dimers in DNA from irradiated cells. However, a low level of unscheduled DNA synthesis could be detected following irradiation at 193 nm with 70 J/m2. Both the 193-nm and 248-nm radiation were able to induce chromosomal aberrations, as indicated by a micronucleus assay. A dose-dependent increase in micronuclei frequency was observed 48 and 72 h after laser irradiation. These results indicate that exposure of actively replicating human skin fibroblasts to sublethal doses of either 193- or 248-nm laser radiation can result in genotoxicity.

  19. Comparative study of efficacy of excimer light therapy vs. intralesional triamcinolone vs. topical 5% minoxidil for alopecia areata: an observational study

    Directory of Open Access Journals (Sweden)

    Zo Nun Sanga

    2015-06-01

    Full Text Available Introduction. Alopecia areata (AA is a chronic inflammatory disease that involves hair follicles, and sometimes nails, caused by a T-cell mediated autoimmune mechanism. Current treatment modalities include corticosteroids (oral, topical or intralesional, minoxidil, contact sensitizers (DNCB, DPCP and SADBE, immunosuppressants (methotrexate or azathioprine, DMARDs (sulfasalazine, and phototherapy. Objective. To compare the efficacy of excimer light therapy, intralesional triamcinolone and 5% topical minoxidil. Material and methods. After taking consent, 40 patients were treated with excimer light, 46 patients with intralesional triamcinolone injection and 14 patients with 5% topical minoxidil. The results were compared by their photographs taken prior to treatment, at 2 months and 6 months of follow-up. Results. Among the excimer group, 21/32 (61.76% patients with a single patch and 1/6 (16.67% with multiple patches achieved > 50% hair regrowth. In the triamcinolone group, 23/30 (76.67% with a single patch and 10/16 (62.5% with multiple patches achieved > 50% hair regrowth, and in the minoxidil group, 4/12 (33.33% with a single patch and none, i.e. 0/2, with multiple patches achieved > 50% regrowth. Conclusions. After comparing the efficacy of excimer light therapy, intralesional triamcinolone and 5% minoxidil, it was concluded that intralesional triamcinolone seems to be the most efficacious. Multiple AA patches were more resistant than a single patch. Scalp response was much better than beard.

  20. Consistent comparison of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided LASIK for myopia by EX500 excimer laser.

    Science.gov (United States)

    Sun, Ming-Shen; Zhang, Li; Guo, Ning; Song, Yan-Zheng; Zhang, Feng-Ju

    2018-01-01

    To evaluate and compare the uniformity of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided ablation of laser in situ keratomileusis (LASIK) by EX500 excimer laser for myopia. Totally 145 cases (290 consecutive eyes )with myopia received LASIK with a target of emmetropia. The ablation for 86 cases (172 eyes) was guided manually based on Oculyzer topography (study group), while the ablation for 59 cases (118 eyes) was guided automatically by Topolyzer Vario topography (control group). Measurement of adjustment values included data respectively in horizontal and vertical direction of cornea. Horizontally, synclastic adjustment between manually actual values (dx manu ) and Oculyzer topography guided data (dx ocu ) accounts 35.5% in study group, with mean dx manu /dx ocu of 0.78±0.48; while in control group, synclastic adjustment between automatically actual values (dx auto ) and Oculyzer topography data (dx ocu ) accounts 54.2%, with mean dx auto /dx ocu of 0.79±0.66. Vertically, synclastic adjustment between dy manu and dy ocu accounts 55.2% in study group, with mean dy manu /dy ocu of 0.61±0.42; while in control group, synclastic adjustment between dy auto and dy ocu accounts 66.1%, with mean dy auto /dy ocu of 0.66±0.65. There was no statistically significant difference in ratio of actual values/Oculyzer topography guided data in horizontal and vertical direction between two groups ( P =0.951, 0.621). There is high consistency in angle Kappa adjustment guided manually by Oculyzer and guided automatically by Topolyzer Vario topography during corneal refractive surgery by WaveLight EX500 excimer laser.

  1. Microencapsulation of silicon cavities using a pulsed excimer laser

    KAUST Repository

    Sedky, Sherif M.

    2012-06-07

    This work presents a novel low thermal-budget technique for sealing micromachined cavities in silicon. Cavities are sealed without deposition, similar to the silicon surface-migration sealing process. In contrast to the 1100°C furnace anneal required for the migration process, the proposed technique uses short excimer laser pulses (24ns), focused onto an area of 23mm 2, to locally heat the top few microns of the substrate, while the bulk substrate remains near ambient temperature. The treatment can be applied to selected regions of the substrate, without the need for special surface treatments or a controlled environment. This work investigates the effect of varying the laser pulse energy from 400 mJ cm 2to 800 mJ cm 2, the pulse rate from 1Hz to 50Hz and the pulse count from 200 to 3000 pulses on sealing microfabricated cavities in silicon. An analytical model for the effect of holes on the surface temperature distribution is derived, which shows that much higher temperatures can be achieved by increasing the hole density. A mechanism for sealing the cavities is proposed, which indicates how complete sealing is feasible. © 2012 IOP Publishing Ltd.

  2. Unscheduled DNA synthesis in human skin after in vitro ultraviolet-excimer laser ablation

    International Nuclear Information System (INIS)

    Green, H.A.; Margolis, R.; Boll, J.; Kochevar, I.E.; Parrish, J.A.; Oseroff, A.R.

    1987-01-01

    DNA damage repaired by the excision repair system and measured as unscheduled DNA synthesis (UDS) was assessed in freshly excised human skin after 193 and 248 nm ultraviolet (UV)-excimer laser ablative incisions. Laser irradiation at 248 nm induced DNA damage throughout a zone of cells surrounding the ablated and heat-damaged area. In contrast, with 193 nm irradiation UDS was not detected in cells adjacent to the ablated area, even though DNA strongly absorbs this wavelength. Our results suggest that the lack of UDS after 193 nm irradiation is due to: ''shielding'' of DNA by the cellular interstitium, membrane, and cytoplasm, DNA damage that is not repaired by excision repair, or thermal effects that either temporarily or permanently inhibit the excision repair processes

  3. The effect of excimer laser keratectomy on corneal glutathione peroxidase activities and aqueous humor selenium levels in rabbits.

    Science.gov (United States)

    Yis, Ozgür; Bilgihan, Ayşe; Bilgihan, Kamil; Yis, Nilgün Safak; Hasanreisoğlu, Berati

    2002-06-01

    The formation of free oxygen radicals has been demonstrated in the corneal tissue after 193 nm laser irradiation. Cornea has several defense mechanisms that protect against oxidative damage. One of them, glutathione peroxidase (GPx), catalyzes the destruction of hydrogen peroxide and lipid hydroperoxide. Selenium is a trace element which is incorporated into the selenoenzyme GPx. In the present study, the effect of excimer laser keratectomy on corneal GPx activities and aqueous humor selenium concentrations in rabbits was evaluated. Animals were divided into five groups, and all groups were compared: controls (group 1), after epithelial scraping (group 2), transepithelial photorefractive keratectomy(PRK; group 3), superficial traditional PRK (50 microm; group 4) and deep traditional PRK (100 microm; group 5). Corneal GPx activities were measured by a modification of the coupled assay procedure. Aqueous humor selenium concentrations were determined using hydride generation atomic absorption spectrometry. Corneal GPx activities were significantly lower only in group 5 ( P<0.05), and the selenium concentration in the aqueous humor did not change in any group. Deep corneal photoablation inhibits GPx enzyme activities in the cornea. Therefore, antioxidants may be useful in reducing free radical-mediated complications after excimer laser corneal photoablation.

  4. Periodic morphological modification developed on the surface of polyethersulfone by XeCl excimer laser photoablation

    International Nuclear Information System (INIS)

    Niino, H.; Nakano, M.; Nagano, S.; Yabe, A.; Miki, T.; Center for Structure Analyses, Teijin Limited, Asahigaoka, Hino, Tokyo, 191 Japan)

    1989-01-01

    Periodic and stable micropatterns appeared on the surface of amorphous polyethersulfone etched with an excimer laser at 308 nm in ambient air and a vacuum. The control of such radiative conditions as fluence and incident angle enables us to modify the spacing and pattern of the microstructures. A topographical investigation with scanning electron microscopy and an experiment with x-ray photoelectron spectroscopy to determine its composition is reported

  5. Surface studies on benzophenone doped PDMS microstructures fabricated using KrF excimer laser direct write lithography

    International Nuclear Information System (INIS)

    Kant, Madhushree Bute; Shinde, Shashikant D.; Bodas, Dhananjay; Patil, K.R.; Sathe, V.G.; Adhi, K.P.; Gosavi, S.W.

    2014-01-01

    Graphical abstract: - Highlights: • Use of KrF Laser micromachining for Lab-On-Chip applications at lower fluence. • Addition of Benzophenone in PDMS enhances its self development sensitivity. • Benzophenone helps efficient energy transfer for equal density of bond scissioning. • Correlation of chemical composition with laser dose and microstructure. • Microstructures with well defined clean sidewalls. - Abstract: This paper discusses microfabrication process for benzophenone doped polydimethylsiloxane (PDMS) using laser lithography. KrF excimer laser of 248 nm with 20 ns pulse width at repetition rate of 1 Hz was used for microfabrication of undoped and benzophenone doped PDMS. The doped-PDMS shows sensitivity below 365 nm, permitting processing under ambient light. The analysis of etch depth revealed that doped PDMS shows self developable sensitivity at lower fluence of ∼250 mJ/cm 2 . The unexposed and exposed surface was studied using Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and Scanning electron microscopy (SEM). Spectrocopic analysis indicated increase in C-O, C=O, Si-O 3 and Si-O 4 bonding at the expense of Si-C and Si-O 2 bonds of PDMS. In case of laser exposed doped-PDMS, removal of benzophenone from probe depth of spectroscopy was observed. Whereas the surface morphology of exposed and unexposed doped-PDMS was observed to be same, indicating clean development of PDMS micropatterns. The present study indicates that addition of 3.0 wt.% benzophenone in PDMS enhance self development sensitivity of PDMS. The self developable results on doped-PDMS are quite encouraging for its potential use in point of care Lab-On-Chip applications, for fabricating micropatterns using direct write laser lithography technology

  6. Excimer laser annealing of shallow As and B doped layers

    International Nuclear Information System (INIS)

    Monakhov, E.V.; Svensson, B.G.; Linnarsson, M.K.; Magna, A. La; Privitera, V.; Camalleri, M.; Fortunato, G.; Mariucci, L.

    2004-01-01

    Excimer laser annealing (ELA) of As-, B- and BF 2 -implanted Si has been studied by secondary ion mass spectrometry (SIMS), spreading resistance probe (SRP) and transmission electron microscopy (TEM). The implantations have been performed in the energy range from 1 to 30 keV with doses of 10 15 -10 16 cm -2 . ELA has been carried out with the energy densities in the range of 600-1200 mJ/cm 2 and the number of laser pulses from 1 to 10. It is shown that ELA results in a more uniform dopant distribution over the doped region with a more abrupt profile edge as compared to those after rapid thermal annealing (RTA). Besides, in contrast to RTA, ELA demonstrates a highly confined annealing effect, where the distribution of dopants below the melting region is not affected. SRP measurements demonstrate almost complete activation of the implanted dopants after ELA, and TEM does not reveal extended defects in the ELA-treated samples. The depth of the doped layers, abruptness of the profiles and the total doping dose as a function of ELA energy density and number of laser pulses are investigated. Computer simulations of ELA show a good agreement with the experimental data

  7. Boron distribution in silicon after excimer laser annealing with multiple pulses

    International Nuclear Information System (INIS)

    Monakhov, E.V.; Svensson, B.G.; Linnarsson, M.K.; La Magna, A.; Italia, M.; Privitera, V.; Fortunato, G.; Cuscuna, M.; Mariucci, L.

    2005-01-01

    We have studied B re-distribution in Si after excimer laser annealing (ELA) with multiple laser pulses. B was implanted using both B and BF 2 ions with energies from 1 to 20 keV and doses of 1 x 10 14 and 1 x 10 15 cm -2 . ELA with the number of pulses from 1 to 100 was performed in vacuum with the sample kept at room temperature and 450 deg. C. Independently of the implantation parameters and the ELA conditions used, a peak in the B concentration is observed near the maximum melting depth after 10 pulses of ELA. A detailed study has revealed that B accumulates at the maximum melt depth gradually with the number of ELA pulses. An increase in the carrier concentration at the maximum melt depth is observed after ELA with 100 pulses. No structural defects have been detected by transmission electron microscopy in the region of the B accumulation

  8. 308-nm excimer lamp for the treatment of alopecia areata: Clinical trial on 16 cases

    Directory of Open Access Journals (Sweden)

    Akiko Ohtsuki

    2013-01-01

    Full Text Available Background: Alopecia areata (AA is considered as a T-cell mediated autoimmune disorder. The 308-nm excimer laser is thought to be capable of inducing T-cell apoptosis in vitro, suggesting that the 308-nm excimer lamp (not laser might be effective for the treatment of AA. We examined the effectiveness of the 308-nm excimer lamp for treating AA. Materials and Methods: We treated 16 patients with single AA and multiple AA (MAA. The lesions were irradiated with a 308-nm excimer lamp at 2-week intervals. Results: Hair regrowth was observed in 14 patients. Among them, 10 patients showed more than 50% hair re-growth. Our results suggested that the 308-nm excimer lamp system is effective and safe for the treatment of single AA and MAA. Conclusion: Our results suggest that the 308-nm excimer lamp is a good therapeutic alternative without serious side effect for treating AA.

  9. Unscheduled DNA synthesis in human skin after in vitro ultraviolet-excimer laser ablation

    Energy Technology Data Exchange (ETDEWEB)

    Green, H.A.; Margolis, R.; Boll, J.; Kochevar, I.E.; Parrish, J.A.; Oseroff, A.R.

    1987-08-01

    DNA damage repaired by the excision repair system and measured as unscheduled DNA synthesis (UDS) was assessed in freshly excised human skin after 193 and 248 nm ultraviolet (UV)-excimer laser ablative incisions. Laser irradiation at 248 nm induced DNA damage throughout a zone of cells surrounding the ablated and heat-damaged area. In contrast, with 193 nm irradiation UDS was not detected in cells adjacent to the ablated area, even though DNA strongly absorbs this wavelength. Our results suggest that the lack of UDS after 193 nm irradiation is due to: ''shielding'' of DNA by the cellular interstitium, membrane, and cytoplasm, DNA damage that is not repaired by excision repair, or thermal effects that either temporarily or permanently inhibit the excision repair processes.

  10. ArF excimer laser modulation of TNF-alpha and gelatinase B in NIH 3T3 cells

    International Nuclear Information System (INIS)

    Naudy-Vives, C.; Courant, D.; Perot, J.C.; Garcia, J.; Fretier, P.; Court, L.; Dormont, D.

    1995-01-01

    The effects on TNF-alpha and gelatinase B activity in mammalian cells induced by 193 nm argon fluoride excimer laser have been investigated. The data show that a secretion of 92 kDa type IV collagenase and TNF-alpha were increased in cell culture supernatants. Moreover, the 193 nm laser radiation produces a decrease of cell proliferation and an increase of cell activation 8 hours after irradiation. The total protein amount increases with the delivered dose. Same, but less effects were obtained after exposure to a conventional UV lamp at 254 nm. (author)

  11. A retrospective comparison of efficacy and safety of 680 consecutive lasik treatments for high myopia performed with two generations of flying-spot excimer lasers.

    Science.gov (United States)

    Gazieva, Lola; Beer, Mette Hjuler; Nielsen, Kim; Hjortdal, Jesper

    2011-12-01

    To compare the visual refractive outcome and complication of laser in situ keratomileusis (LASIK) carried out with a Carl Zeiss-Meditec MEL-70 Excimer laser and a MEL-80 laser for treatment of high myopia. Journal records of 680 consecutive eyes that underwent LASIK with a Schwind Supratome microkeratome and a MEL-70 Excimer laser (Group A), or a Moria M2 microkeratome and a MEL-80 Excimer laser (Group B) were reviewed. Manifest refraction, uncorrected and best spectacle-corrected visual acuity (BSCVA), corneal topography and central corneal thickness (CCT) were recorded before and 3 months after treatment. Pre- and postoperative complications, visual and refractive outcome and frequency of retreatments were registered. Mean preoperative spherical equivalent refraction was -8.52 dioptres (-5.50- -18 dioptres), and the mean attempted laser correction was -8.02 dioptres (-5.50- -11 dioptres). Three months after LASIK, the average treatment error (difference between achieved and attempted correction) was 1.20 (SD=1.19) dioptres of under correction in Group A and 0.52 (SD=1.00) dioptres in Group B. Four eyes lost more than two lines of BSCVA (0.6%). In 110 eyes (16%), a re-LASIK procedure was performed to reduce remaining myopia after the primary procedure. Laser in situ keratomileusis treatment for high myopia can effectively reduce high degrees of myopia. Under correction was observed in both treatment groups but Group B has a slightly better predictability. Significant loss of BSCVA occurs infrequently after LASIK for even considerable grades of myopia (0.6% in each group). © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  12. Comparative study of efficacy of excimer light therapy vs intralesional triamcinolone vs topical 5% minoxidil: an observational study

    Directory of Open Access Journals (Sweden)

    Zonunsanga

    2015-01-01

    Full Text Available Introduction: Alopecia Areota is a chronic inflammatory disease that involves hair follicles, and sometimes nails, caused by T-cell mediated autoimmune mechanism. Current treatment modalities includes corticosteroids (oral, topical or intralesional, Minoxidil, Contact sensitizers like DNCB, DPCP and SADBE, Immunosuppressants like Methotrexate or Azathioprine, DMARDs like Sulfasalazine, and Phototherapy. Materials and methods: After taking consent, 40 patients treated with excimer light, 46 patients treated with triamcinolone injection intralesionally and 14 patients treated with topical minoxidil 5% were compared by their photographs taken prior to treatments, at 2 months and 6 months follow up. Results: Among the excimer group, 21/32 (61.76% with single patch and 1/6 (16.67% with multiple patches achieved >50% hair regrowth. Among Triamcinolone group, 23/30 (76.67% with single patch and 10/16 (62.5% with multiple patches achieved >50% hair regrowth. Among the Minoxidil group, 4/12 (33.33% with single patch and none .i.e 0/2 with multiple patches achieved >50% regrowth. Conclusion: After comparing the efficacy of Excimer light therapy, intralesional triamcinolone and 5% Minoxidil, it was concluded that intralesional triamcinolone seems to be the most efficacious. Multiple patches were more resistant than single patch. Scalp response much better than beard.

  13. A comparative study of via drilling and scribing on PEN and PET substrates for flexible electronic applications using excimer and Nd:YAG laser sources

    NARCIS (Netherlands)

    Mandamparambil, R.; Fledderus, H.; Brand, J. van den; Saalmink, M.; Kusters, R.; Podprocky, T.; Steenberge, G. van; Baets, J. de; Dietzel, A.H.

    2009-01-01

    A study on via drilling and channel scribing on PEN and PET substrates for flexible electronic application is discussed in this paper. For the experiments, both KIF excimer laser (248 nm) and frequency tripled Nd:YAG (355 nm) laser are used. Different measurement techniques like optical microscopy,

  14. Excimer laser sintering of indium tin oxide nanoparticles for fabricating thin films of variable thickness on flexible substrates

    International Nuclear Information System (INIS)

    Park, Taesoon; Kim, Dongsik

    2015-01-01

    Technology to fabricate electrically-conducting, transparent thin-film patterns on flexible substrates has possible applications in flexible electronics. In this work, a pulsed-laser sintering process applicable to indium tin oxide (ITO) thin-film fabrication on a substrate without thermal damage to the substrate was developed. A nanosecond pulsed laser was used to minimize thermal penetration into the substrate and to control the thickness of the sintered layer. ITO nanoparticles (NPs) of ~ 20 nm diameter were used to lower the process temperature by exploiting their low melting point. ITO thin film patterns were fabricated by first spin coating the NPs onto a surface, then sintering them using a KrF excimer laser. The sintered films were characterized using field emission scanning electron microscopy. The electrical resistivity and transparency of the film were measured by varying the process parameters. A single laser pulse could generate the polycrystalline structure (average grain size ~ 200 nm), reducing the electrical resistivity of the film by a factor of ~ 1000. The sintering process led to a minimum resistivity of 1.1 × 10 −4 Ω·m without losing the transparency of the film. The thickness of the sintered layer could be varied up to 150 nm by adjusting the laser fluence. Because the estimated thermal penetration depth in the ITO film was less than 200 nm, no thermal damage was observed in the substrate. This work suggests that the proposed process, combined with various particle deposition methods, can be an effective tool to form thin-film ITO patterns on flexible substrates. - Highlights: • Excimer laser sintering can fabricate ITO thin films on flexible substrates. • The laser pulse can form a polycrystalline structure without thermal damage. • The laser sintering process can reduce the electrical resistivity substantially. • The thickness of the sintered layer can be varied effectively

  15. Excimer laser sintering of indium tin oxide nanoparticles for fabricating thin films of variable thickness on flexible substrates

    Energy Technology Data Exchange (ETDEWEB)

    Park, Taesoon; Kim, Dongsik, E-mail: dskim87@postech.ac.kr

    2015-03-02

    Technology to fabricate electrically-conducting, transparent thin-film patterns on flexible substrates has possible applications in flexible electronics. In this work, a pulsed-laser sintering process applicable to indium tin oxide (ITO) thin-film fabrication on a substrate without thermal damage to the substrate was developed. A nanosecond pulsed laser was used to minimize thermal penetration into the substrate and to control the thickness of the sintered layer. ITO nanoparticles (NPs) of ~ 20 nm diameter were used to lower the process temperature by exploiting their low melting point. ITO thin film patterns were fabricated by first spin coating the NPs onto a surface, then sintering them using a KrF excimer laser. The sintered films were characterized using field emission scanning electron microscopy. The electrical resistivity and transparency of the film were measured by varying the process parameters. A single laser pulse could generate the polycrystalline structure (average grain size ~ 200 nm), reducing the electrical resistivity of the film by a factor of ~ 1000. The sintering process led to a minimum resistivity of 1.1 × 10{sup −4} Ω·m without losing the transparency of the film. The thickness of the sintered layer could be varied up to 150 nm by adjusting the laser fluence. Because the estimated thermal penetration depth in the ITO film was less than 200 nm, no thermal damage was observed in the substrate. This work suggests that the proposed process, combined with various particle deposition methods, can be an effective tool to form thin-film ITO patterns on flexible substrates. - Highlights: • Excimer laser sintering can fabricate ITO thin films on flexible substrates. • The laser pulse can form a polycrystalline structure without thermal damage. • The laser sintering process can reduce the electrical resistivity substantially. • The thickness of the sintered layer can be varied effectively.

  16. Influence of laser fluence in ArF-excimer laser assisted crystallisation of a-SiGe:H films

    International Nuclear Information System (INIS)

    Chiussi, S.; Lopez, E.; Serra, J.; Gonzalez, P.; Serra, C.; Leon, B.; Fabbri, F.; Fornarini, L.; Martelli, S.

    2003-01-01

    Polycrystalline silicon germanium (poly-SiGe) coatings are drawing increasing attention as active layers in solar cells, bolometers and various microelectronic devices. As a consequence, alternative low-cost production techniques, capable to produce such alloys with uniform and controlled grain size, become more and more attractive. Excimer laser assisted crystallisation, already assessed in thin film transistor production, has proved to be a valuable 'low-thermal budget' technique for the crystallisation of amorphous silicon. Main advantages are the high process quality and reproducibility as well as the possibility of tailoring the grain size in both, small selected regions and large areas. The feasibility of this technique for producing poly-SiGe films has been studied irradiating hydrogenated amorphous SiGe films with spatially uniform ArF-laser pulses of different fluences. Surface morphology, structure and chemical composition have been extensively characterised, demonstrating the need of using a 'step-by-step' process and a careful adjustment of both, total number of shots and laser fluence at each 'step' in order to diminish segregation effects and severe damages of the film surface and of segregation effects

  17. Does imiquimod pretreatment optimize 308-nm excimer laser (UVB) therapy in psoriasis patients?

    Science.gov (United States)

    Tacastacas, Joselin D; Oyetakin-White, Patricia; Soler, David C; Young, Andrew; Groft, Sarah; Honda, Kord; Cooper, Kevin D; McCormick, Thomas S

    2017-07-01

    Psoriasis continues to be a debilitating skin disease affecting 1-3% of the United States population. Although the effectiveness of several current biologic therapies have described this pathology as a IL-23, TNF-a and Th17-mediated disease, less invasive approaches are still in use and in need of refinement. One of these is the usage of narrow band-UVB (NB-UVB) therapy to deplete specifically intra-epidermal CD3+, CD4+ and CD8+ cells to clear psoriatic plaques. In order to improve NB-UVB therapy, we sought to determine whether skin pre-treatment with the TLR7 agonist imiquimod (IMQ) would help increase the efficiency of the former at resolving psoriatic plaques. Eucerin ® Original Moisturizing Lotion (topical vehicle) or Aldara ® (imiquimod 5% topical cream) were applied for 5 days once daily to a maximum contiguous area of 25 cm 2 (5 cm × 5 cm area). Patients were provided with sachets containing 12.5 mg of imiquimod each and were instructed to apply imiquimod (I) to two psoriasis plaques (5 sachets of imiquimod allotted to each plaque). A PHAROS excimer Laser EX-308 (Ra Medical Systems, Inc. Carlsbad, CA, USA) with an output of monochromatic 308-nm light and pulse width of 20-50 ns was used for all patients. Punch biopsies of psoriatic lesions (6 mm) were taken at 4 and 48 h after final application of topical treatment with or without excimer laser treatment. Real-time quantitative RT-PCR was performed according to manufacturer's instructions and Inmunohistochemistry was used as described before. Our results suggests that although IMQ seemed to activate the type I interferon pathway as previously described, its concomitant usage with NB-UVB for clearing psoriatic skin was ineffective. Although upregulation of genes MxA, GRAMD1A and DMXL2 suggested that IMQ treatment did induce skin changes in psoriasis patients, more optimal dosing of IMQ and NB-UVB might be necessary to achieve desired treatment responses. The observation that psoriasis involvement was not

  18. Surface studies on benzophenone doped PDMS microstructures fabricated using KrF excimer laser direct write lithography

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Madhushree Bute; Shinde, Shashikant D. [Department of Physics, University of Pune, Pune 411007 (India); Bodas, Dhananjay [Centre for Nanobioscience, Agharkar Research Institute, Agharkar road, Pune 411004 (India); Patil, K.R. [Center for Materials Characterization, National Chemical Laboratories, Pune 411008 (India); Sathe, V.G. [UGC DAE Inter University Consortium, Indore 452017 (India); Adhi, K.P. [Department of Physics, University of Pune, Pune 411007 (India); Gosavi, S.W., E-mail: swg@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411007 (India)

    2014-09-30

    Graphical abstract: - Highlights: • Use of KrF Laser micromachining for Lab-On-Chip applications at lower fluence. • Addition of Benzophenone in PDMS enhances its self development sensitivity. • Benzophenone helps efficient energy transfer for equal density of bond scissioning. • Correlation of chemical composition with laser dose and microstructure. • Microstructures with well defined clean sidewalls. - Abstract: This paper discusses microfabrication process for benzophenone doped polydimethylsiloxane (PDMS) using laser lithography. KrF excimer laser of 248 nm with 20 ns pulse width at repetition rate of 1 Hz was used for microfabrication of undoped and benzophenone doped PDMS. The doped-PDMS shows sensitivity below 365 nm, permitting processing under ambient light. The analysis of etch depth revealed that doped PDMS shows self developable sensitivity at lower fluence of ∼250 mJ/cm{sup 2}. The unexposed and exposed surface was studied using Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and Scanning electron microscopy (SEM). Spectrocopic analysis indicated increase in C-O, C=O, Si-O{sub 3} and Si-O{sub 4} bonding at the expense of Si-C and Si-O{sub 2} bonds of PDMS. In case of laser exposed doped-PDMS, removal of benzophenone from probe depth of spectroscopy was observed. Whereas the surface morphology of exposed and unexposed doped-PDMS was observed to be same, indicating clean development of PDMS micropatterns. The present study indicates that addition of 3.0 wt.% benzophenone in PDMS enhance self development sensitivity of PDMS. The self developable results on doped-PDMS are quite encouraging for its potential use in point of care Lab-On-Chip applications, for fabricating micropatterns using direct write laser lithography technology.

  19. The European answer to the integration issues of excimer laser annealing in MOS technology

    International Nuclear Information System (INIS)

    Privitera, V.; La Magna, A.; Fortunato, G.; Camalleri, M.; Magri, A.; Simon, F.; Svensson, B.G.

    2004-01-01

    Excimer laser annealing (ELA) of MOSFET devices is currently studied and evaluated within the frame of the IST project 'Fundamentals and applications of laser processing for highly innovative MOS technology' (FLASH), funded by the European Commission. This European consortium aim to demonstrate that ELA can be industrialized in the context of semiconductor device fabrication. The technical achievement of homogeneous irradiation of entire wafers by industrial line beam system set up has been combined with device design solutions, in order to avoid the detrimental effects of the laser beam on device structures and tackle the integration issues, main obstacles for the use of ELA in the semiconductor industry. The launch of ELA, to open a new market segment in the semiconductor industry, implies also the availability of reliable process simulation tools. Therefore, a simulation program based on the phase-field method was produced, fully working and available

  20. Properties of the ablation process for excimer laser ablation of Y1Ba2Cu3O7

    International Nuclear Information System (INIS)

    Neifeld, R.A.; Potenziani, E.; Sinclair, W.R.; Hill III, W.T.; Turner, B.; Pinkas, A.

    1991-01-01

    The process of excimer laser ablation has been studied while varying the laser fluence from 0.237 to 19.1 J/cm 2 . Ion time-of-flight, total charge, target etch depth per pulse, and etch volume per pulse have been measured. Results indicate a maximum ablation volume and minimum ionization fraction occur near 5 J/cm 2 . Several of the parameters measured vary rapidly in the 1--5 J/cm 2 range. Variation in these parameters strongly influences the properties of films grown by this technique

  1. Effect of pulsed laser light in patients with dry eye syndrome.

    Science.gov (United States)

    Guilloto Caballero, S; García Madrona, J L; Colmenero Reina, E

    2017-11-01

    The objective of this study was to determine the clinical benefits of pulsed light therapy for the treatment of Dry Eye Syndrome (DES) due to the decrease in aqueous tear production (aqueous deficient DES) and/or excessive tear evaporation (evaporative DES) due to Meibomian Gland Dysfunction (MGD). A study was conducted on 72 eyes corresponding to 36 patients with DES. Out of these 72 eyes, 60 underwent refractive surgery (48 with femtosecond laser, 6 were operated with a mechanical microkeratome, and 6 with refractive photo-keratectomy[RPK], 6 treated with phacoemulsification, and 6 with no previous surgical treatment. Pulsed laser light (Intense Pulsed Light Regulated [IRPL ® ]) was use to stimulate the secretion of the Meibomian glands during 4 sessions, one every 15 days. Patients with aqueous deficient DES did not show any improvement. Eyes with no previous surgery and those treated with phacoemulsification and PRK had a favourable outcome. On the other hand, less conclusive results were observed in the eyes treated with excimer laser. This treatment could be very helpful to treat evaporative DES produced by MGD. On the other hand, it is not helpful for those cases related to an isolated damage in the aqueous phase, or the mucin phase. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. UV excimer laser and low temperature plasma treatments of polyamide materials

    Science.gov (United States)

    Yip, Yiu Wan Joanne

    Polyamides have found widespread application in various industrial sectors, for example, they are used in apparel, home furnishings and similar uses. However, the requirements for high quality performance products are continually increasing and these promote a variety of surface treatments for polymer modification. UV excimer laser and low temperature plasma treatments are ideally suited for polyamide modification because they can change the physical and chemical properties of the material without affecting its bulk features. This project aimed to study the modification of polyamides by UV excimer laser irradiation and low temperature plasma treatment. The morphological changes in the resulting samples were analysed by scanning electron microscopy (SEM) and tapping mode atomic force microscopy (TM-AFM). The chemical modifications were studied by x-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS) and chemical force microscopy (CFM). Change in degree of crystallinity was examined by differential scanning calorimetry (DSC). After high-fluence laser irradiation, topographical results showed that ripples of micrometer size form on the fibre surface. By contrast, sub-micrometer size structures form on the polyamide surface when the applied laser energy is well below its ablation threshold. After high-fluence laser irradiation, chemical studies showed that the surface oxygen content of polyamide is reduced. A reverse result is obtained with low-fluence treatment. The DSC result showed no significant change in degree of crystallinity in either high-fluence or low-fluence treated samples. The same modifications in polyamide surfaces were studied after low temperature plasma treatment with oxygen, argon or tetrafluoromethane gas. The most significant result was that the surface oxygen content of polyamide increased after oxygen and argon plasma treatments. Both treatments induced many hydroxyl (-OH) and carboxylic acid (-COOH

  3. Laser-driven hydrothermal process studied with excimer laser pulses

    Science.gov (United States)

    Mariella, Raymond; Rubenchik, Alexander; Fong, Erika; Norton, Mary; Hollingsworth, William; Clarkson, James; Johnsen, Howard; Osborn, David L.

    2017-08-01

    Previously, we discovered [Mariella et al., J. Appl. Phys. 114, 014904 (2013)] that modest-fluence/modest-intensity 351-nm laser pulses, with insufficient fluence/intensity to ablate rock, mineral, or concrete samples via surface vaporization, still removed the surface material from water-submerged target samples with confinement of the removed material, and then dispersed at least some of the removed material into the water as a long-lived suspension of nanoparticles. We called this new process, which appears to include the generation of larger colorless particles, "laser-driven hydrothermal processing" (LDHP) [Mariella et al., J. Appl. Phys. 114, 014904 (2013)]. We, now, report that we have studied this process using 248-nm and 193-nm laser light on submerged concrete, quartzite, and obsidian, and, even though light at these wavelengths is more strongly absorbed than at 351 nm, we found that the overall efficiency of LDHP, in terms of the mass of the target removed per Joule of laser-pulse energy, is lower with 248-nm and 193-nm laser pulses than with 351-nm laser pulses. Given that stronger absorption creates higher peak surface temperatures for comparable laser fluence and intensity, it was surprising to observe reduced efficiencies for material removal. We also measured the nascent particle-size distributions that LDHP creates in the submerging water and found that they do not display the long tail towards larger particle sizes that we had observed when there had been a multi-week delay between experiments and the date of measuring the size distributions. This is consistent with transient dissolution of the solid surface, followed by diffusion-limited kinetics of nucleation and growth of particles from the resulting thin layer of supersaturated solution at the sample surface.

  4. Surface modification of Al–Si alloy by excimer laser pulse processing

    Energy Technology Data Exchange (ETDEWEB)

    Mahanty, S., E-mail: soumitro@iitk.ac.in; Gouthama

    2016-04-15

    The laser irradiation on Al-Si alloy sample is carried out by excimer laser in ambient conditions for 30 or 45 pulses. Microstructural investigation of laser treated sample is done by OM, SEM and TEM and the surface hardness is evaluated by Vickers micro indentation. Laser treated, samples suggested the dissolution of coarse primary Si and β-AlFeSi particle in α-Al matrix. The SEM/EDS study shows the enhancement of retained Si in α-Al matrix. The interface analysis of laser treated sample suggested the effected modified depth is ∼6 μm. TEM investigation shows the formation of nanocrystalline Si in size ∼2–15 nm. The cellular structures of size range ∼30–50 nm are observed after 45 pulses. The α-Al cells and Si precipitates sizes were considerably refined at higher number of pulses. The fine Si precipitates are found to be dispersed in the intercellular boundaries. An improvement in surface hardness from ∼1.6 to 1.8 is observed 30 and 45 pulse treatment, respectively. The mechanism involves for improvement in surface properties are non-equilibrium solidification, metastable phase formation and microstructural refinement. - Highlights: • Coarse Si and β phase intermetallic are melted and the constituent elements dispersed into the matrix during re-solidification. • The solid solubility of the Si at the surface enhanced after the laser treatment. • The Cellular structure with the size range ∼30–50 nm observed in α-Al after 45 laser pulses. • Si nano particles in size ∼ 2–15 nm were observed in the intercellular region. • Surface hardness increased after laser processing.

  5. Comparison of Placido disc and Scheimpflug image-derived topography-guided excimer laser surface normalization combined with higher fluence CXL: the Athens Protocol, in progressive keratoconus

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2013-07-01

    decreased to -18.35% and the index of height decentration to -39.03%. These reductions indicate that the corneal surface became less irregular (index of surface variance and the “cone” flatter and more central (index of height decentration postoperatively.Conclusion: Of the two sources of primary corneal data, the Scheimpflug rotating camera (Oculyzer™ for topography-guided normalization treatment with the WaveLight excimer laser platform appeared to provide more statistically significant improvement than the Placido disc topographer (Topolyzer™. Overall, the Athens protocol, aiming both to halt progression of keratoconic ectasia and to improve corneal topometry and visual performance, produced safe and satisfactory refractive, keratometric, and topometric results. The observed changes in visual acuity, along with keratometric flattening and topometric improvement, are suggestive of overall postoperative improvement.Keywords: Athens protocol, anterior Pentacam indices, keratoconus, cross-linking, WaveLight/Alcon excimer laser, EX500 excimer laser, higher fluence collagen cross-linking

  6. Latest result of PRK with excimer laser

    Science.gov (United States)

    Okamoto, Shinseiro; Okamoto, Michika

    1996-05-01

    We have in the last two years, performed PRK operation on over 300 human myopic eyes using ArF excimer laser with a Summit 'Omnimed' machine. For the initial 53 myopic eyes we treated, results were very good for those with correction less than minus 6 diopters. However, as previously reported, we also witnessed some regression for those eyes exceeding correction of more than minus 6 diopters. To counter such ill results of PRK we devised and suggested many new procedures for PRK with very good results. One such invention is the 'Okamoto-type' cooling machine for the cornea which reduces and stabilizes cornea temperature at 0 degrees Celsius while simultaneously bathing the cornea with special cooling fluid. After the operation, EGF, fibronectin and hexapeptide were administered using eyedrops. Soft contact lenses were used to protect the cornea, improve delivery of medication to the operated area, prevent infection and inflammation and also promote uniform and faster ephiterium regrowth. We were able to document very good post-operative results using this method, thereby giving us strong assurance that we have reached a significant milestone in PRK operation. Our report today covers post operative results of the 52 eyes we operated on and tracked for more than one year.

  7. Excimer laser recrystallization of nanocrystalline-Si films deposited by inductively coupled plasma chemical vapour deposition at 150 deg. C

    International Nuclear Information System (INIS)

    Park, Joong-Hyun; Han, Sang-Myeon; Park, Sang-Geun; Han, Min-Koo; Shin, Moon-Young

    2006-01-01

    Polycrystalline silicon thin film transistors (poly-Si TFTs) fabricated at low temperature (under 200 deg. C) have been widely investigated for flexible substrate applications such as a transparent plastic substrate. Unlike the conventional TFT process using glass substrate, the maximum process temperature should be kept less than 200 deg. C in order to avoid thermal damage on flexible substrates. We report the characteristics of nanocrystalline silicon (nc-Si) irradiated by an excimer laser. Nc-Si precursors were deposited on various buffer layers by inductively coupled plasma chemical vapour deposition (ICP-CVD) at 150 deg. C. We employed various buffer layers, such as silicon nitride (SiN X ) and silicon dioxide (SiO 2 ), in order to report recrystallization characteristics in connection with a buffer layer of a different thermal conductivity. The dehydrogenation and recrystallization was performed by step-by-step excimer laser annealing (ELA) (XeCl,λ=308 nm) in order to prevent the explosive release of hydrogen atoms. The grain size of the poly-Si film, which was recrystallized on the various buffer layers, was measured by scanning electron microscopy (SEM) at each laser energy density. The process margin of step-by-step ELA employing the SiN X buffer layer is wider than SiO 2 and the maximum grain size slightly increased

  8. Studies of free radicals by ultraviolet excimer laser photolysis. Progress report, 1 April 1980-1 November 1980

    International Nuclear Information System (INIS)

    Leone, S.R.

    1980-01-01

    An experimental technique has been developed to produce and directly study vibrationally excited free radicals. Pulses of light from an ultraviolet excimer laser are used to photodissociate small molecules to generate free radicals with high internal excitation. The radicals are detected directly by the technique of time and wavelength-resolved infrared emission spectroscopy using a background-limited copper-doped germanium infrared detector. New results have been obtained on the CH 3 radical. A complete spectrum of the CH 3 umbrella band reveals for the first time accurate positions of the vibrational progression in this band. Photofragmentation of (CH 3 ) 2 Hg has yielded detailed information on the vibrational distribution, rotational temperature, and deactivation rates of the CH 3 stretch mode. A technique to study chemical chain reactions using low power, radical-specific, laser initiation and realtime kinetics detection had previously been demonstrated. The results provide a general method to study a large number of chain reaction combustion systems in greater detail. New results on more complex chain reactions such as Cl 2 /butane reveal that highly detailed infrared emission spectra of various products of the chain and their time evolution is possible. Partitioning of energy between vibrational degrees of freedom and translational heating is obtained over the course of the combustion

  9. Study on excimer laser irradiation for controlled dehydrogenation and crystallization of boron doped hydrogenated amorphous/nanocrystalline silicon multilayers

    International Nuclear Information System (INIS)

    Gontad, F.; Conde, J.C.; Filonovich, S.; Cerqueira, M.F.; Alpuim, P.; Chiussi, S.

    2013-01-01

    We report on the excimer laser annealing (ELA) induced temperature gradients, allowing controlled crystallization and dehydrogenation of boron-doped a-Si:H/nc-Si:H multilayers. Depth of the dehydrogenation and crystallization process has been studied numerically and experimentally, showing that temperatures below the monohydride decomposition can be used and that significant changes of the doping profile can be avoided. Calculation of temperature profiles has been achieved through numerical modeling of the heat conduction differential equation. Increase in the amount of nano-crystals, but not in their size, has been demonstrated by Raman spectroscopy. Effective dehydrogenation and shape of the boron profile have been studied by time of flight secondary ion mass spectroscopy. The relatively low temperature threshold for dehydrogenation, below the monohydride decomposition temperature, has been attributed to both, the large hydrogen content of the original films and the partial crystallization during the ELA process. The results of this study show that UV-laser irradiation is an effective tool to improve crystallinity and dopant activation in p + -nc-Si:H films without damaging the substrate. - Highlights: • An efficient dehydrogenation is possible through excimer laser annealing. • 140 mJ/cm 2 is enough for dehydrogenation without significant changes in doping profile. • Fluences up to 300 mJ/cm 2 promote partial crystallization of the amorphous structures

  10. Study on excimer laser irradiation for controlled dehydrogenation and crystallization of boron doped hydrogenated amorphous/nanocrystalline silicon multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Gontad, F., E-mail: fran_gontad@yahoo.es [Applied Physics Department, University of Vigo, E.I. Industrial, Campus de As Lagoas, Marcosende, E-36310, Vigo (Spain); Conde, J.C. [Applied Physics Department, University of Vigo, E.I. Industrial, Campus de As Lagoas, Marcosende, E-36310, Vigo (Spain); Filonovich, S.; Cerqueira, M.F.; Alpuim, P. [Department of Physics, University of Minho, Campus de Azurém, 4800-058 Guimarães (Portugal); Chiussi, S. [Applied Physics Department, University of Vigo, E.I. Industrial, Campus de As Lagoas, Marcosende, E-36310, Vigo (Spain)

    2013-06-01

    We report on the excimer laser annealing (ELA) induced temperature gradients, allowing controlled crystallization and dehydrogenation of boron-doped a-Si:H/nc-Si:H multilayers. Depth of the dehydrogenation and crystallization process has been studied numerically and experimentally, showing that temperatures below the monohydride decomposition can be used and that significant changes of the doping profile can be avoided. Calculation of temperature profiles has been achieved through numerical modeling of the heat conduction differential equation. Increase in the amount of nano-crystals, but not in their size, has been demonstrated by Raman spectroscopy. Effective dehydrogenation and shape of the boron profile have been studied by time of flight secondary ion mass spectroscopy. The relatively low temperature threshold for dehydrogenation, below the monohydride decomposition temperature, has been attributed to both, the large hydrogen content of the original films and the partial crystallization during the ELA process. The results of this study show that UV-laser irradiation is an effective tool to improve crystallinity and dopant activation in p{sup +}-nc-Si:H films without damaging the substrate. - Highlights: • An efficient dehydrogenation is possible through excimer laser annealing. • 140 mJ/cm{sup 2} is enough for dehydrogenation without significant changes in doping profile. • Fluences up to 300 mJ/cm{sup 2} promote partial crystallization of the amorphous structures.

  11. Excimer laser processing of ZnO thin films prepared by the sol-gel process

    International Nuclear Information System (INIS)

    Winfield, R.J.; Koh, L.H.K.; O'Brien, Shane; Crean, Gabriel M.

    2007-01-01

    ZnO thin films were prepared on soda-lime glass from a single spin-coating deposition of a sol-gel prepared with anhydrous zinc acetate [Zn(C 2 H 3 O 2 ) 2 ], monoethanolamine [H 2 NC 2 H 4 OH] and isopropanol. The deposited films were dried at 50 and 300 deg. C. X-ray analysis showed that the films were amorphous. Laser annealing was performed using an excimer laser. The laser pulse repetition rate was 25 Hz with a pulse energy of 5.9 mJ, giving a fluence of 225 mJ cm -2 on the ZnO film. Typically, five laser pulses per unit area of the film were used. After laser processing, the hexagonal wurtzite phase of zinc oxide was observed from X-ray diffraction pattern analysis. The thin films had a transparency of greater than 70% in the visible region. The optical band-gap energy was 3.454 eV. Scanning electron microscopy and profilometry analysis highlighted the change in morphology that occurred as a result of laser processing. This comparative study shows that our sol-gel processing route differs significantly from ZnO sol-gel films prepared by conventional furnace annealing which requires temperatures above 450 deg. C for the formation of crystalline ZnO

  12. Aqueous transforming growth factor-beta-I levels in rabbit eyes after excimer laser photoablation.

    Science.gov (United States)

    Bilgihan, K; Gürelik, G; Okur, H; Bilgihan, A; Hasanreisoglu, B; Imir, T

    1997-01-01

    Transforming growth factor beta (TGF-beta) plays an important role in anterior segment wound healing, by controlling the cell proliferation and differentiation, angiogenesis, extracellular matrix composition and mediating the immunosuppressive properties of the aqueous humor. The present study was undertaken to clarify the possible changes of aqueous humor TGF-betaI levels after excimer laser photoablation. Twenty-eight New Zealand rabbits were divided into four groups of 7 rabbits each. Group 1 served as control, the central 7 mm of corneal epithelium was removed in groups 2, 3 and 4. We performed 50-microm corneal photoablation in group 3, and 100-microm ablation in group 4. After 48 h we measured the TGF-betaI levels of the aqueous humor by ELISA method. The mean TGF-betaI value of the aqueous humor was found to be 162.94+/-13.73 pg/ml in the control group. Mechanical deepithelialization did not change the TGF-betaI levels of the aqueous humor (p > 0.05). There was no significant difference between the 50-microm photoablated group and the controls (p > 0.05), but the TGF-betaI levels of the 100-microm photoablated group were found to be significantly higher than those of both the control group and 50-microm photoablated group (p < 0.05). Many factors and cytokines may induce corneal haze and myopic regression after excimer laser photoablation; our study demonstrated that TGF-betaI is one of these factors and there is a positive correlation between the depth of corneal photoablation and aqueous TGF-betaI concentrations.

  13. Advanced excimer-based crystallization systems for production solutions

    International Nuclear Information System (INIS)

    Simon, F.; Brune, J.; Herbst, L.

    2006-01-01

    Line beam excimer laser annealing (ELA) is a well-known technique for thin Si-film crystallization and established in LTPS mass production. With introduction of sequential lateral solidification (SLS) some aspects such as crystalline quality, throughput and flexibility regarding the substrate size could be improved, but for OLED manufacturing still further process development is necessary. This paper discusses line beam ELA and SLS-techniques that might enable process engineers to make polycrystalline-silicon (poly-Si) films with a high degree of uniformity and quality as required for system on glass (SOG) and active matrix organic light emitting displays (AMOLED). Equipment requirements are discussed and compared to previous standards. SEM-images of process examples are shown in order to demonstrate the viability

  14. 80 A/cm2 electron beams from metal targets irradiated by KrCl and XeCl excimer lasers

    Science.gov (United States)

    Beloglazov, A.; Martino, M.; Nassisi, V.

    1996-05-01

    Due to the growing demand for high-current and long-duration electron-beam devices, laser electron sources were investigated in our laboratory. Experiments on electron-beam generation and propagation from aluminium and copper targets illuminated by XeCl (308 nm) and KrCl (222 nm) excimer lasers, were carried out under plasma ignition due to laser irradiation. This plasma supplied a spontaneous accelerating electric field of about 370 kV/m without an external accelerating voltage. By applying the modified one-dimensional Poisson equation, we computed the expected current and we also estimated the plasma concentration during the accelerating process. At 40 kV of accelerating voltage, an output current pulse of about 80 A/cm2 was detected from an Al target irradiated by the shorter wavelength laser.

  15. Excimer laser doping technique for application in an integrated CdTe imaging device

    CERN Document Server

    Mochizuki, D; Aoki, T; Tomita, Y; Nihashi, T; Hatanaka, Y

    1999-01-01

    CdTe is an attractive semiconductor material for applications in solid-state high-energy X-ray and gamma-ray imaging systems because of its high absorption coefficient, large band gap, good mobility lifetime product of holes and stability at normal atmospheric conditions. We propose a new concept for fabricating an integrated CdTe with monolithic circuit configuration for two-dimensional imaging systems suitable for medical, research or industrial applications and operation at room temperature. A new doping technique has been recently developed that employs excimer laser radiation to diffuse impurity atoms into the semiconductor. Accordingly, heavily doped n- and p-type layers with resistivities less than 1 OMEGA cm can be formed on the high resistive CdTe crystals. We have further extended this technique for doping with spatial pattern. We will present the laser doping technique and various results thus obtained. Spatially patterned doping is demonstrated and we propose the use of these doping techniques for...

  16. Investigations of an excimer laser working with a four-component gaseous mixture He-Kr:Xe-HCl

    Science.gov (United States)

    Iwanejko, Leszek; Pokora, Ludwik J.

    1991-08-01

    The paper presnts working conditions of an XCI excimer laser untypical gas mixture based on KrzXe instead of pure Xe. Such a choice was influenced by the necessity of Findin9 the way to replace imported and expensive Xe by gaseous components accesible in Poland. Determining the range of changes of laser extrnal parameters which enables its proper work with the new gas mixture was the aim of same investigations results of which are presented in this paper. The laser pulse output energy and the pulse duration as a Function of supply voltage and the mixture composition are presented. The range of proper conditions for the laser working with the new mixture He-Kr:Xe--HC1 was determined. The analysis of experimental results showed that using the new mixture ensures value of energy and pulse duration comparable with the ones obtained for the mixture He-''Xe--HCl. Spectral investigations showed the lack of influence of Kr presence in the mixture on the generation spectrum of the laser. L.

  17. [Excimer laser therapy of alopecia areata--side-by-side evaluation of a representative area].

    Science.gov (United States)

    Raulin, Christian; Gündogan, Cüneyt; Greve, Bärbel; Gebert, Susanne

    2005-07-01

    We report for the first time on hair regrowth in alopecia areata of the scalp achieved with the 308-nm xenon-chloride excimer laser in a prospective side-by-side trial. The alopecia areata had shown progression over a period of three years, and various treatments had not been effective. Out of a number of affected areas, one representative lesion was chosen; one half of it was treated, the other half remained untreated. After 27 sessions (200 - 4000 mJ/cm2, cumulative dose 52.6 J/cm2) over 3 months, only the treated area showed hair growth; which suggests that this was most probably not a spontaneous remission.

  18. One-kilohertz eye tracker and active intraoperative torsion detection in the NIDEK CXIII and Quest excimer lasers.

    Science.gov (United States)

    Waring, George O

    2009-10-01

    To describe recent technological additions to the NIDEK CXIII and Quest excimer lasers. A summary article with data from previous published studies outlining the benefits of newer technology. The addition of a 1-kHz infrared eye tracker decreased the spread of laser spot placement from a mean of 228.79 microm without a tracker to 38.47 microm with the eye tracker. The addition of real-time torsion error correction produced a statistically significantly lower cylinder dispersion, mean manifest refractive cylinder, and error of angle postoperatively in eyes that underwent LASIK. The incorporation of an ultrahigh speed eye tracker and active cyclotorsion correction surpasses the minimal technology criteria required for accurate wavefront-based ablations. Copyright 2009, SLACK Incorporated.

  19. Impact of Angioscopic Evaluation for Femoropopliteal In-Stent Restenosis Before and After Excimer Laser Atherectomy.

    Science.gov (United States)

    Idemoto, Akiko; Okamoto, Naotaka; Tanaka, Akihiro; Mori, Naoki; Nakamura, Daisuke; Yano, Masamichi; Makino, Nobuhiko; Egami, Yasuyuki; Shutta, Ryu; Tanouchi, Jun; Nishino, Masami

    2017-07-01

    In-stent restenosis (ISR) is a prevalent problem following stenting of femoropopliteal lesions. A potential novel treatment modality for ISR including excimer laser atherectomy (ELA) has become available. We performed ELA for in-stent chronic total occlusion (CTO) of femoropopliteal lesions and evaluated lesion morphology before and after ELA by angioscopy in 2 patients. The angioscopic findings clearly showed removal of in-stent thrombi after ELA. Thus, ELA may be effective for in-stent CTO of femoropopliteal lesions. This is the first report describing the direct visualization of ELA effect for vaporization of thrombi in femoropopliteal in-stent lesions by angioscopy.

  20. Outcomes of excimer laser enhancements in pseudophakic patients with multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Schallhorn SC

    2016-04-01

    Full Text Available Steven C Schallhorn,1–3 Jan A Venter,2 David Teenan,2 Julie M Schallhorn,3 Keith A Hettinger,2 Stephen J Hannan,2 Martina Pelouskova2 1Department of Ophthalmology, University of California, San Francisco, CA, USA; 2Optical Express, Glasgow, UK; 3Department of Ophthalmology, University of Southern California, Los Angeles, CA, USA Purpose: The aim of this study was to assess visual and refractive outcomes of laser vision correction (LVC to correct residual refraction after multifocal intraocular lens (IOL implantation. Patients and methods: In this retrospective study, 782 eyes that underwent LVC to correct unintended ametropia after multifocal IOL implantation were evaluated. Of all multifocal lenses implanted during primary procedure, 98.7% were refractive and 1.3% had a diffractive design. All eyes were treated with VISX STAR S4 IR excimer laser using a convectional ablation profile. Refractive outcomes, visual acuities, patient satisfaction, and quality of life were evaluated at the last available visit. Results: The mean time between enhancement and last visit was 6.3±4.4 months. Manifest spherical equivalent changed from -0.02±0.83 D (-3.38 D to +2.25 D pre-enhancement to 0.00±0.34 D (-1.38 D to +1.25 D post-enhancement. At the last follow-up, the percentage of eyes within 0.50 D and 1.00 D of emmetropia was 90.4% and 99.5%, respectively. Of all eyes, 74.9% achieved monocular uncorrected distance visual acuity 20/20 or better. The mean corrected distance visual acuity remained the same before (-0.04±0.06 logMAR [logarithm of the minimum angle of resolution] and after LVC procedure (-0.04±0.07 logMAR; P=0.70. There was a slight improvement in visual phenomena (starburst, halo, glare, ghosting/double vision following the enhancement. No sight-threatening complications related to LVC occurred in this study. Conclusion: LVC in pseudophakic patients with multifocal IOL was safe, effective, and predictable in a large cohort of

  1. Influence of spatial and temporal spot distribution on the ocular surface quality and maximum ablation depth after photoablation with a 1050 Hz excimer laser system.

    Science.gov (United States)

    Mrochen, Michael; Schelling, Urs; Wuellner, Christian; Donitzky, Christof

    2009-02-01

    To investigate the effect of temporal and spatial distributions of laser spots (scan sequences) on the corneal surface quality after ablation and the maximum ablation of a given refractive correction after photoablation with a high-repetition-rate scanning-spot laser. IROC AG, Zurich, Switzerland, and WaveLight AG, Erlangen, Germany. Bovine corneas and poly(methyl methacrylate) (PMMA) plates were photoablated using a 1050 Hz excimer laser prototype for corneal laser surgery. Four temporal and spatial spot distributions (scan sequences) with different temporal overlapping factors were created for 3 myopic, 3 hyperopic, and 3 phototherapeutic keratectomy ablation profiles. Surface quality and maximum ablation depth were measured using a surface profiling system. The surface quality factor increased (rough surfaces) as the amount of temporal overlapping in the scan sequence and the amount of correction increased. The rise in surface quality factor was less for bovine corneas than for PMMA. The scan sequence might cause systematic substructures at the surface of the ablated material depending on the overlapping factor. The maximum ablation varied within the scan sequence. The temporal and spatial distribution of the laser spots (scan sequence) during a corneal laser procedure affected the surface quality and maximum ablation depth of the ablation profile. Corneal laser surgery could theoretically benefit from smaller spot sizes and higher repetition rates. The temporal and spatial spot distributions are relevant to achieving these aims.

  2. Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System

    CERN Document Server

    Gentile, C A; Hartfield, J W; Hawryluk, R J; Hegeler, F; Heitzenroeder, P J; Jun, C H; Ku, L P; Lamarche, P H; Myers, M C; Parker, J J; Parsells, R F; Payen, M; Raftopoulos, S; Sethian, J D

    2002-01-01

    The Princeton Plasma Physics Laboratory (PPPL), in collaboration with the Naval Research Laboratory (NRL), is currently investigating various novel materials (single crystal silicon, , and ) for use as electron-beam transmission windows in a KrF excimer laser system. The primary function of the window is to isolate the active medium (excimer gas) from the excitation mechanism (field-emission diodes). Chosen window geometry must accommodate electron energy transfer greater than 80% (750 keV), while maintaining structural integrity during mechanical load (1.3 to 2.0 atm base pressure differential, approximate 0.5 atm cyclic pressure amplitude, 5 Hz repetition rate) and thermal load across the entire hibachi area (approximate 0.9 W centre dot cm superscript ''-2''). In addition, the window must be chemically resistant to attack by fluorine free-radicals (hydrofluoric acid, secondary). In accordance with these structural, functional, and operational parameters, a 22.4 mm square silicon prototype window, coated w...

  3. Deposition and characterization of ITO films produced by laser ablation at 355 nm

    DEFF Research Database (Denmark)

    Holmelund, E.; Thestrup Nielsen, Birgitte; Schou, Jørgen

    2002-01-01

    Indium tin oxide (ITO) films have been deposited by pulsed laser deposition (PLD) at 355 nm. Even though the absorption of laser light at the wavelength 355 nm is much smaller than that of the standard excimer lasers for PLD at 248 nm and 193 nm, high-quality films can be produced. At high fluence...

  4. Analysis of excimer laser radiant exposure effect toward corneal ablation volume at LASIK procedure

    Science.gov (United States)

    Adiati, Rima Fitria; Rini Rizki, Artha Bona; Kusumawardhani, Apriani; Setijono, Heru; Rahmadiansah, Andi

    2016-11-01

    LASIK (Laser Asissted In Situ Interlamelar Keratomilieusis) is a technique for correcting refractive disorders of the eye such as myopia and astigmatism using an excimer laser. This procedure use photoablation technique to decompose corneal tissues. Although preferred due to its efficiency, permanency, and accuracy, the inappropriate amount radiant exposure often cause side effects like under-over correction, irregular astigmatism and problems on surrounding tissues. In this study, the radiant exposure effect toward corneal ablation volume has been modelled through several processes. Data collecting results is laser data specifications with 193 nm wavelength, beam diameter of 0.065 - 0.65 cm, and fluence of 160 mJ/cm2. For the medical data, the myopia-astigmatism value, cornea size, corneal ablation thickness, and flap data are taken. The first modelling step is determining the laser diameter between 0.065 - 0.65 cm with 0.45 cm increment. The energy, power, and intensity of laser determined from laser beam area. Number of pulse and total energy is calculated before the radiant exposure of laser is obtained. Next is to determine the parameters influence the ablation volume. Regression method used to create the equation, and then the spot size is substituted to the model. The validation used is statistic correlation method to both experimental data and theory. By the model created, it is expected that any potential complications can be prevented during LASIK procedures. The recommendations can give the users clearer picture to determine the appropriate amount of radiant exposure with the corneal ablation volume necessary.

  5. Structuring of poly ether ether ketone by ArF excimer laser radiation in different atmospheres

    International Nuclear Information System (INIS)

    Feng, Y.; Gottmann, J.; Kreutz, E.W.

    2003-01-01

    Structuring of poly ether ether ketone (PEEK) by 193 nm ArF excimer laser radiation has been investigated. Experiments were carried out in different atmospheres (air, vacuum, Ar, O 2 ) in order to study its influence on the quality of the structures and the formation of the debris. Repetition rate makes little effect on the ablation rate and roughness of the structure in presence of any kind of atmosphere, indicating for the structuring of PEEK by ArF laser radiation a large window of processing. The roughness at the bottom of the structures and the morphology of the side walls are strongly affected by the properties of the atmosphere. The smallest roughness is achieved at 0.6 J/cm 2 for all kinds of processing gases. Debris around the structures can be diminished by structuring in vacuum. Plasma expansion speed has been measured by using high speed photography

  6. Gasochromic performance of WO3-nanorod thin films fabricated with an ArF excimer laser

    International Nuclear Information System (INIS)

    Yaacob, M. H.; Ou, J. Z.; Wlodarski, W.; Kim, C. S.; Lee, J. Y.; Kim, Y. H.; Oh, C. M.; Dhakal, K. P.; Kim, J. Y.; Kang, J. H.

    2012-01-01

    Thin films with tungsten trioxide (WO 3 ) nanorods were fabricated by using an ArF pulsed laser deposition system. Because the ArF excimer laser operates at a very short wavelength of 193 nm, short enough to expect strong absorption of the photons in the semiconductor oxide targets, and because the clusters incoming to the substrates have high momentum, we could build thin films with good surface morphology. Highly homogeneous arrays of nanorods with sizes mostly in the range of 30 - 40 nm were observed. The absorbance response towards hydrogen (H 2 ) gas was investigated for a WO 3 film coated with 25-A-thick palladium (Pd). The Pd/WO 3 -nanorod thin films exhibited excellent gasochromic response when measured in the visible-NIR range (400 - 1000 nm). As low as 0.06% H 2 concentration was clearly sensed. A significant reversible absorbance change and fast recovery ( 2 at different concentrations.

  7. Preparation of PZT/YBCO/YAlO heterostructure thin films by KrF excimer laser ablation

    International Nuclear Information System (INIS)

    Ebihara, Kenji; Kurogi, Hiromitsu; Yamagata, Yukihiko; Ikegami, Tomoaki; Grishin, A.M.

    1998-01-01

    The perovskite oxide YBa 2 Cu 3 O 7-x (YBCO) and Pb(Zr x Ti 1-x )O 3 (PZT) thin films have been deposited for superconducting-ferroelectric devices. KrF excimer laser ablation technique was used at the deposition conditions of 200--600 mTorr O 2 , 2-3J/cm 2 and 5--10 Hz operation frequency. Heterostructures of PZT-YBCO-YAlO 3 :Nd show the zero resistivity critical temperature of 82 K and excellent ferroelectric properties of remnant polarization 32 microC/cm 2 , coercive force of 80 kV/cm and dielectric constant 800. Cycling fatigue characteristics and leakage current are also discussed

  8. Laser Physics and Physics with Lasers - Recent Advances

    International Nuclear Information System (INIS)

    Marowsky, G.

    2008-01-01

    This contribution reviews the development as well as recent technological advances in the field of optics with lasers and laser-related applications. Topics ranging from 'attoscience' to 'zero-modes' shall be dealt with in this presentation. Further reading in the following references is suggested: Springer Handbook of Lasers and Optics (F. Trager, ed.), 2007, ISBN-13: 978-0-387-95579-7; Chapter 11.7, Part C: Ultraviolet Lasers: Excimers, Fluorine (F2), Nitrogen (N2), pp. 764-776; Excimer Laser Technology (D. Basting, G. Marowsky, eds.) 2005, Springer, ISBN-13 978-3-540-20056-7

  9. Study on the surface chemical properties of UV excimer laser irradiated polyamide by XPS, ToF-SIMS and CFM

    International Nuclear Information System (INIS)

    Yip, Joanne; Chan, Kwong; Sin, Kwan Moon; Lau, Kai Shui

    2002-01-01

    Polyamide (nylon 6) was irradiated by a pulsed ultraviolet (UV) excimer laser with a fluence below its ablation threshold. Chemical modifications on laser treated nylon were studied by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (Tof-SIMS) and chemical force microscopy (CFM). XPS study provides information about changes in chemical composition and the chemical-state of atom types on the fiber surface. The high sensitivity of ToF-SIMS to the topmost layers was used to detect crosslinking after the laser treatment. Gold-coated AFM tips modified with -COOH terminated self-assembled alkanethiol monolayers (SAMs) were used to measure adhesion forces on the untreated and laser treated samples. XPS results revealed that the irradiated samples have higher oxygen content than prior to laser irradiation. Tof-SIMS analysis illustrated that carbonyl groups in nylon 6 decrease significantly but hydroxyl groups increase after low-fluence laser irradiation. The adhesion force measurements by CFM showed spatial distribution of hydroxyl groups on nylon 6 after the laser treatment

  10. Evaluation of the performance of small diode pumped UV solid state (DPSS) Nd:YAG lasers as new radiation sources for atmospheric pressure laser ionization mass spectrometry (APLI-MS).

    Science.gov (United States)

    Kersten, Hendrik; Lorenz, Matthias; Brockmann, Klaus J; Benter, Thorsten

    2011-06-01

    The performance of a KrF* bench top excimer laser and a compact diode pumped UV solid state (DPSS) Nd:YAG laser as photo-ionizing source in LC-APLI MS is compared. The commonly applied bench-top excimer laser, operating at 248 nm, provides power densities of the order of low MW/cm(2) on an illuminated area of 0.5 cm(2) (8 mJ/pulse, 5 ns pulse duration, beam waist area 0.5 cm(2), 3 MW/cm(2)). The DPSS laser, operating at 266 nm, provides higher power densities, however, on a two orders of magnitude smaller illuminated area (60 μJ/pulse, 1 ns pulse duration, beam waist area 2 × 10(-3) cm(2), 30 MW/cm(2)). In a common LC-APLI MS setup with direct infusion of a 10 nM pyrene solution, the DPSS laser yields a significantly smaller ion signal (0.9%) and signal to noise ratio (1.4%) compared with the excimer laser. With respect to the determined low detection limits (LODs) for PAHs of 0.1 fmol using an excimer laser, LODs in DPSS laser LC-APLI MS in the low pmol regime are expected. The advantages of the DPSS laser with respect to applicability (size, cost, simplicity) may render this light source the preferred one for APLI applications not focusing on ultimately high sensitivities. Furthermore, the impact of adjustable ion source parameters on the performance of both laser systems is discussed in terms of the spatial sensitivity distribution described by the distribution of ion acceptance (DIA) measurements. Perspectives concerning the impact on future APLI-MS applications are given.

  11. Dopant redistribution and electrical activation in silicon following ultra-low energy boron implantation and excimer laser annealing

    International Nuclear Information System (INIS)

    Whelan, S.; La Magna, A.; Privitera, V.; Mannino, G.; Italia, M.; Bongiorno, C.; Fortunato, G.; Mariucci, L.

    2003-01-01

    Excimer laser annealing (ELA) of ultra-low-energy (ULE) B-ion implanted Si has been performed. High-resolution transmission electron microscopy has been used to assess the as-implanted damage and the crystal recovery following ELA. The electrical activation and redistribution of B in Si during ELA has been investigated as a function of the laser energy density (melted depth), the implant dose, and the number of laser pulses (melt time). The activated and retained dose has been evaluated with spreading resistance profiling and secondary ion mass spectrometry. A significant amount of the implanted dopant was lost from the sample during ELA. However, the dopant that was retained in crystal material was fully activated following rapid resolidification. At an atomic concentration below the thermodynamic limit, the activation efficiency (dose activated/dose implanted into Si material) was a constant for a fixed melt depth, irrespective of the dose implanted and hence the total activated dose was raised as the implant dose was increased. The electrical activation was increased for high laser energy density annealing when the dopant was redistributed over a deeper range

  12. Pulsed Er:YAG- and 308 nm UV-excimer laser: an in vitro and in vivo study of skin-ablative effects

    Energy Technology Data Exchange (ETDEWEB)

    Kaufmann, R.; Hibst, R.

    1989-01-01

    Using a pulsed XeCl excimer laser (308 nm) and a pulsed Er:YAG laser (2,940 nm), we investigated skin ablation as a function of pulse number, radiant energy, and repetition rate. In vitro analysis of lesions performed in freshly excised human skin were consistent with in vivo results obtained from experiments on pig skin. Pulsed 308 nm laser radiation caused considerable nonspecific thermal tissue injury followed by an inflammatory reaction and impaired healing of lesions in vivo. These findings were especially pronounced with higher repetition rates, which would be required for efficient destruction of larger lesions. On the other hand, the 2.94 microns Er:YAG laser radiation produced clean and precise lesions with only minimal adjacent injury. In vivo skin ablation caused intraoperative bleeding with deeper penetration. The Er:YAG laser offers a promising surgical tool for careful removal of superficial epidermal lesions, if higher repetition rates, and an appropriate laser beam delivery system are available for clinical use.

  13. Numerical analysis of temperature profile and thermal-stress during excimer laser induced heteroepitaxial growth of patterned amorphous silicon and germanium bi-layers deposited on Si(100)

    Energy Technology Data Exchange (ETDEWEB)

    Conde, J.C., E-mail: jconde@uvigo.e [Dpto. Fisica Aplicada, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, E-36310 Vigo (Spain); Martin, E. [Dpto. de Mecanica, Maquinas y Motores Termicos y Fluidos, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, E-36310 Vigo (Spain); Gontad, F.; Chiussi, S. [Dpto. Fisica Aplicada, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, E-36310 Vigo (Spain); Fornarini, L. [Enea-Frascati, Via Enrico Fermi 45, I-00044 Frascati (Roma) (Italy); Leon, B. [Dpto. Fisica Aplicada, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, E-36310 Vigo (Spain)

    2010-02-26

    A Finite Element Method (FEM) study of the coupled thermal-stress during the heteroepitaxial growth induced by excimer laser radiation of patterned amorphous hydrogenated silicon (a-Si:H) and germanium (a-Ge:H) bi-layers deposited on a Si(100) wafer is presented. The ArF (193 nm) excimer laser provides high energy densities during very short laser pulse (20 ns) provoking, at the same time, melting and solidification phenomena in the range of several tenths of nanoseconds. These phenomena play an important role during the growth of heteroepitaxial SiGe structures characterized by high Ge concentration buried under a Si rich surface. In addition, the thermal-stresses that appear before the melting and after the solidification processes can also affect to the epitaxial growth of high quality SiGe alloys in these patterned structures and, in consequence, it is necessary to predict their effects. The aim of this work is to estimate the energy threshold and the corresponding thermal-stresses in the interfaces and the borders of these patterned structures.

  14. Numerical analysis of temperature profile and thermal-stress during excimer laser induced heteroepitaxial growth of patterned amorphous silicon and germanium bi-layers deposited on Si(100)

    International Nuclear Information System (INIS)

    Conde, J.C.; Martin, E.; Gontad, F.; Chiussi, S.; Fornarini, L.; Leon, B.

    2010-01-01

    A Finite Element Method (FEM) study of the coupled thermal-stress during the heteroepitaxial growth induced by excimer laser radiation of patterned amorphous hydrogenated silicon (a-Si:H) and germanium (a-Ge:H) bi-layers deposited on a Si(100) wafer is presented. The ArF (193 nm) excimer laser provides high energy densities during very short laser pulse (20 ns) provoking, at the same time, melting and solidification phenomena in the range of several tenths of nanoseconds. These phenomena play an important role during the growth of heteroepitaxial SiGe structures characterized by high Ge concentration buried under a Si rich surface. In addition, the thermal-stresses that appear before the melting and after the solidification processes can also affect to the epitaxial growth of high quality SiGe alloys in these patterned structures and, in consequence, it is necessary to predict their effects. The aim of this work is to estimate the energy threshold and the corresponding thermal-stresses in the interfaces and the borders of these patterned structures.

  15. Properties of the ablation process for excimer laser ablation of Y sub 1 Ba sub 2 Cu sub 3 O sub 7

    Energy Technology Data Exchange (ETDEWEB)

    Neifeld, R.A.; Potenziani, E. (United States Army, Electronics Technology and Devices Laboratory, Fort Monmouth, New Jersey 07703-5000 (US)); Sinclair, W.R. (Martin Goffman Associates, 3 Dellview Drive, Edison, New Jersey 08820-2545 (US)); Hill III, W.T.; Turner, B.; Pinkas, A. (Institute for Physical Science and Technology, University of Maryland, College Park, Maryland 20742 (US))

    1991-01-15

    The process of excimer laser ablation has been studied while varying the laser fluence from 0.237 to 19.1 J/cm{sup 2}. Ion time-of-flight, total charge, target etch depth per pulse, and etch volume per pulse have been measured. Results indicate a maximum ablation volume and minimum ionization fraction occur near 5 J/cm{sup 2}. Several of the parameters measured vary rapidly in the 1--5 J/cm{sup 2} range. Variation in these parameters strongly influences the properties of films grown by this technique.

  16. Excimer lamp pumped by a triggered discharge

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, G.; Bollanti, S.; Di Lazzaro, P.; Flora, F.; Giordano, G.; Letardi, T.; Renieri, A.; Schina, G. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dip. Innovazione; Clementi, G.; Muzzi, F.; Zheng, C.E. [EL.EN. (Electronic Engineering), Florence (Italy)

    1996-11-01

    Radiation characteristics and discharge performances of an excimer lamp are described. The discharge of the HCl/Xe gas mixture at an atmospheric pressure, occurring near the quartz tube wall, is initiated by a trigger wire. A maximum total UV energy of about 0.4 J in a (0.8-0.9) {mu}s pulse, radiated from a 10 cm discharge length, is obtained with a total discharge input energy of 8 J. Excimer lamps are the preferred choice for medical and material processing irradiations, when the monochromaticity or coherence of UV light is not required, due to their low cost, reliability and easy maintenance.

  17. Excimers of organic molecules

    Science.gov (United States)

    Barashkov, Nikolai N.; Sakhno, T. V.; Nurmukhametov, Ravil'N.; Khakhel', O. A.

    1993-06-01

    Studies devoted to excimers in organic systems are surveyed. Processes leading to the excitation of the excimer luminescence are examined. Examples of the excimer-like glow of dimers are described. The relation between the structure of the complexes and their fluorescence properties is demonstrated. The bibliography includes 218 references.

  18. Comparison of boron diffusion in silicon during shallow p{sup +}/n junction formation by non-melt excimer and green laser annealing

    Energy Technology Data Exchange (ETDEWEB)

    Aid, Siti Rahmah; Matsumoto, Satoru [Department of Electronics and Electrical Engineering, Keio University, 3-14-1 Hiyoshi, Kouhoku-ku, Yokohama, Kanagawa 223-8522 (Japan); Fuse, Genshu [SEN Corporation, SBS Tower 9F, 4-10-1 Yoga, Setagaya-ku, Tokyo 158-0097 (Japan); Sakuragi, Susumu [Sumitomo Heavy Industries Ltd., 19 Natsushima-cho, Yokosuka, Kanagawa 237-8555 (Japan)

    2011-12-15

    The combination of Ge pre-amorphization implantation, low-energy boron implantation, and non-melt laser annealing is a promising method for forming ultrashallow p{sup +}/n junctions in silicon. In this study, shallow p{sup +}/n junctions were formed by non-melt annealing implanted samples using a green laser (visible laser). The dopant diffusion, activation, and recrystallization of an amorphous silicon layer were compared with those obtained in our previous study in which non-melt annealing was performed using a KrF excimer laser (UV laser). The experimental results reveal that only slight diffusion of boron in the tail region occurred in green-laser-annealed samples. In contrast, remarkable boron diffusion occurred in KrF-laser-annealed samples for very short annealing times. Recrystallization of the amorphous silicon layer was slower in green-laser-annealed samples than in KrF-laser-annealed samples. We consider the penetration depth and the pulse duration are important factors that may affect boron diffusion. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Boron-enhanced diffusion in excimer laser annealed Si

    International Nuclear Information System (INIS)

    Monakhov, E.V.; Svensson, B.G.; Linnarsson, M.K.; La Magna, A.; Privitera, V.; Fortunato, G.; Mariucci, L.

    2004-01-01

    The effect of excimer laser annealing (ELA) and rapid thermal annealing (RTA) on B redistribution in B-implanted Si has been studied by secondary ion mass spectrometry (SIMS) and spreading resistance probe (SRP). B has been implanted with an energy of 1 keV and a dose of 10 16 cm -2 forming a distribution with a width of 20-30 nm and a peak concentration of ∼5 x 10 21 cm -3 . It has been found that ELA with 10 pulses of the energy density of 850 mJ/cm 2 results in a uniform B distribution over the ELA-molten region with an abrupt profile edge. SRP measurements demonstrate good activation of the implanted B after ELA, with the concentration of the activated fraction (∼10 21 cm -3 ) exceeding the solid solubility level. RTA (30 s at 1100 deg. C) of the as-implanted and ELA-treated samples leads to a diffusion of B with diffusivities exceeding the equilibrium one and the enhancement is similar for both of the samples. It is also found that RTA decreases the activated B in the ELA-treated sample to the solid solubility limit (2 x 10 20 cm -3 ). The similarity of the B diffusivity for the as-implanted and ELA-treated samples suggests that the enhancement of the B diffusivity is due to the so-called boron-enhanced diffusion (BED). Possible mechanisms of BED are discussed

  20. Enabling laser applications in microelectronics manufacturing

    Science.gov (United States)

    Delmdahl, Ralph; Brune, Jan; Fechner, Burkhard; Senczuk, Rolf

    2016-02-01

    In this experimental study, we report on high-pulse-energy excimer laser drilling into high-performance build-up films which are pivotal in microelectronics manufacturing. Build-up materials ABF-GX13 from Ajinomoto as well as ZS-100 from Zeon Corporation are evaluated with respect to their viability for economic excimer laser-based micro-via formation. Excimer laser mask imaging projection at laser wavelengths of 193, 248 and 308 nm is employed to generate matrices of smaller micro-vias with different diameters and via pitches. High drilling quality is achievable for all excimer laser wavelengths with the fastest ablation rates measured in the case of 248 and 308 nm wavelengths. The presence of glass fillers in build-up films as in the ABF-GX13 material poses some limitations to the minimum achievable via diameter. However, surprisingly good drilling results are obtainable as long as the filler dimensions are well below the diameter of the micro-vias. Sidewall angles of vias are controllable by adjusting the laser energy density and pulse number. In this work, the structuring capabilities of excimer lasers in build-up films as to taper angle variations, attainable via diameters, edge-stop behavior and ablation rates will be elucidated.

  1. On the origin of excimer emission in electroluminescence and photoluminescence spectra of polyfluorenes

    International Nuclear Information System (INIS)

    Vacha, Martin; Ha, Jaekook; Sato, Hisaya

    2007-01-01

    We report a study on the differences in red-shifted excimer band in photoluminescence (PL) and electroluminescence (EL) spectra of thin films of a copolymer of dibutylfluorene and butylphenylphenoxazine. The relative intensity of the excimer band in PL spectra increases with temperature above the polymer glass transition, and with the intensity of the excitation light. In EL spectra, on the other hand, the relative excimer intensity is seen to decrease with increasing driving voltage. These opposite trends originate from the different nature of excitations in PL and EL spectra: photoexcitation directly creates singlet excitons while electric excitation proceeds via interaction of injected electrons and holes. In case of electric excitation, the observed results might be due to trap-assisted excimer formation

  2. Application of laser resonance scattering to the study of high-temperature plasma-wall interaction

    International Nuclear Information System (INIS)

    Maeda, Mitsuo; Muraoka, Katsunori; Hamamoto, Makoto; Akazaki, Masanori; Miyazoe, Yasushi

    1981-01-01

    Studies on laser resonance scattering and its application to the study of high-temperature plasma-wall interaction are reviewed. The application of dye laser beam to resonant scattering method has been developed. This method is able to detect low density atoms. The fluorescent photon counts can be estimated for a two-level system and a three-level system. The S/N ratio, Which is in close connection with the detection limit, has been estimated. The doppler effect due to the thermal motion of atoms is taken into consideration. The calibration of the absolute number of atoms is necessary. Tunable coherent light is used as the light source for resonance scattering method. This is able to excite atoms strongly and to increase the detection efficiency. As dye lasers, a N 2 laser, a YAG laser, and a KrF excimer laser have been studied. In VUV region, rare gas or rare gas halide lasers can be used. The strong output power can be expected when the resonance lines of atoms meet the synchronizing region of the excimer laser. The resonance scattering method is applied to the detection of impurity metal atoms in plasma. The studies of laser systems for the detection of hydrogen atoms are also in progress. (Kato, T.)

  3. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2015-01-01

    Purpose: To evaluate and compare long-term outcomes ofafter photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. Methods: Retrospective single-masked follow-up study of patients treated for myopia between 2007 and 2009 with cPRK...... or LASEK, using a high-frequency flying-spot excimer laser with eye-tracker (MEL80; Carl Zeiss, Jena, Germany). One eye of each patient was randomly chosen for analysis. Re-treated eyes were excluded. Results: Forty-six cPRK patients and 35 LASEK patients were included. Spherical equivalent averaged -7.......69 ± 1.47 diopters (D) in cPRK eyes and -7.98 ± 2.06 D in LASEK eyes (P=0.31) before surgery. Average follow-up time was 4.6 years in cPRK patients and 6.0 years in LASEK patients (PPRK eyes and 1 LASEK eye (P=0.46) had lost 2 lines of corrected distance visual acuity...

  4. O impacto da cirurgia de ceratectomia fotorrefrativa (PRK e ceratomileuse assistida por excimer laser in situ (LASIK na qualidade visual e de vida em pacientes com ametropias The impact of photorefractive excimer laser keratectomy (PRK and laser in situ keratomileusis (LASIK on visual quality and life in patients with ametropias

    Directory of Open Access Journals (Sweden)

    Ricardo Belfort

    2008-02-01

    Full Text Available OBJETIVO: Avaliar a qualidade de vida e de visão e o estresse de pacientes portadores de ametropias submetidos a procedimentos cirúrgicos. MÉTODOS: Estudo longitudinal observacional em que foram estudados 100 pacientes; 54 usuários de óculos, 21 usuários de lentes de contato interessados no procedimento cirúrgico e 25 controles usuários de óculos ou lentes de contato, mas que não desejavam ser operados no período de um ano. Os questionários aplicados foram o National Eye Institute Visual Function Questionnaire (NEI-VFQ-25 de qualidade de vida e o Self Reporting Questionnaire - SRQ-20 para avaliação da saúde mental. Os pacientes que se submeteram à cirurgia responderam aos questionários aplicados por uma observadora antes da mesma, três, seis e doze meses após a intervenção. O grupo controle respondeu de forma auto-aplicada no início do estudo, seis e doze meses após a primeira avaliação. RESULTADOS: No grupo da cirugia dos 54 pacientes que usavam óculos 39 fizeram cirurgia de ceratectomia fotorrefrativa por excimer laser(PRK e 15 fizeram ceratomileuse assistida por excimer laserin situ (LASIK e dos 21 que usavam lentes de contato 12 fizeram cirurgia de ceratectomia fotorrefrativa e nove fizeram ceratomileuse assistida por excimer laser in situ (LASIK. O grupo controle esteve estável durante os 12 meses em relação aos instrumentos aplicados. Três meses após a cirurgia o grupo da cirurgia apresentou melhora significante da qualidade de vida e de visão em relação ao pré-operatório independentemente do tipo de cirurgia realizada. Um ano após a cirurgia os índices de qualidade de vida e de saúde mental, foram semelhantes aos do grupo controle. O Self Reporting Questionnaire - SRQ 20 mostrou diminuição significante do índice de sintomas a partir dos três meses de pós-operatório. CONCLUSÃO: A qualidade de visão e de vida dos pacientes submetidos à cirurgia de correção de ametropia mudou

  5. excimer laser

    Indian Academy of Sciences (India)

    2014-01-07

    Jan 7, 2014 ... is necessary to deposit one order higher input electric power into gas medium than ... cross-sectional view of the laser system is shown in figure 2A. The system mainly consists ... Considering the simplicity and reliability of the.

  6. Screening for psychiatric distress and low self-esteem in patients presenting for excimer laser surgery for myopia.

    Science.gov (United States)

    Kidd, B; Stark, C; McGhee, C N

    1997-01-01

    Patients presenting for photorefractive keratectomy (PRK) may have unusual psychological profiles. Certain psychological variables may impact treatment outcome, making early identification crucial. We report a controlled questionnaire study of psychiatric "anxiety/distress" and self-esteem in myopic patients who presented for excimer laser treatment. Ninety consecutive myopic individuals (patients) who presented for excimer laser PRK and 50 consecutive myopic individuals who presented to an optometrist for contact lens fitting (controls) were assessed using two self-completion questionnaires-the GHQ30 and Hudson Index of Self-Esteem ISE. The questionnaires were distributed during assessment for treatment. PRK patients had a 90% response rate for both questionnaires and control patients, 98% for GHQ30 and 100% for Hudson ISE. PRK patients were significantly older (p = 0.000003), had a greater myopic spherical equivalent refraction (p = 0.012) and had better spectacle-corrected visual acuity (p = 0.0096). No significant differences were demonstrated with regard to anxiety/distress in terms of absolute scores (p = 0.07), or the proportion of patients being positive or negative (p = 0.10). Similarly, self-esteem was not significantly different between the two groups (absolute scores p = 0.69; positive/negative p = 0.29). The high response rate shows that the GHQ30 and Hudson ISE are easy to use and well tolerated by myopes in a busy clinic setting. The fact that the patients were older, with a greater refractive error, may partly reflect the onset of contact lens intolerance. The psychological findings suggest that PRK patients cannot be considered more distressed or anxious than other myopic individuals. There is no evidence that their decision to undergo surgery is driven by abnormally low self-esteem.

  7. Excimer PRK testing in the clinic

    Science.gov (United States)

    Forrest, Gary T.

    1994-06-01

    Testing of the excimer lasers used in PRK requires special considerations in terms of ease of use, day-to-day reliability, and high resolution to see details of beam interference effects. SensorPhysics employs a patented photochromic material on a polyester substrate to record permanent, instant records of the laser and laser system output. Since each SensorCard is used only once concerns about detection device deterioration are not an issue. The SensorCards have a demonstrated resolving power on the order of 0.1 micrometers . A small, portable reading device is used to convert the SensorCard optical density to a mJ/cm2 value. Special software also measures beam uniformity to +/- 1% to provide both qualitative and quantitative analysis. Results of use in clinic environments will be presented. In particular detection of exposure `islands' will be demonstrated. The techniques employed are similar to those we developed for UV laser micromachining and lithography four years ago.

  8. Excimer laser texturing of natural composite polymer surfaces for studying cell-to-substrate specific response

    Energy Technology Data Exchange (ETDEWEB)

    Dinca, V., E-mail: dincavalentina@yahoo.com [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania); Alloncle, P.; Delaporte, P. [Aix-Marseille University, CNRS, LP3 Laboratory, Campus de Luminy, 13288 Marseille (France); Ion, V. [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania); Faculty of Physics, University of Bucharest, 077125 Magurele (Romania); Rusen, L.; Filipescu, M. [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania); Mustaciosu, C. [Horia Hulubei National Institute of Physics and Nuclear Engineering – IFIN HH, Magurele, Bucharest (Romania); Luculescu, C.; Dinescu, M. [NILPRP, National Institute for Lasers, Plasma and Radiation Physics, Magurele, Bucharest (Romania)

    2015-10-15

    Highlights: • Roughness gradients are obtained in one step by applying single laser pulses and sample tilting. • BSA protein and cell dependence behavior onto gradient characteristics was studied. • The degradation of the samples by lysozyme was correlated to its ability to access the textured area. - Abstract: Surface modifications of biocompatible materials are among the main factors used for enhancing and promoting specific cellular activities (e.g. spreading, adhesion, migration, and differentiation) for various types of medical applications such as implants, microfluidic devices, or tissue engineering scaffolds. In this work an excimer laser at 193 nm was used to fabricate chitosan–collagen roughness gradients. The roughness gradients were obtained in one step by applying single laser pulses and sample tilting. Fourier transform infrared spectroscopy measurements, atomic force microscopy (AFM), scanning electron microscopy (SEM), and spectro-ellipsometry (SE) were used for sample characterization. The goal is to determine the optimal morpho-chemical characteristics of these structures for in vitro tailoring of protein adsorption and cell behavior. The response induced by the roughness gradient onto various cell lines (i.e. L 929 fibroblasts, HEP G2 hepatocytes, OLN 93 oligodendrocytes, M63 osteoblasts) and bovine serum albumin (BSA) protein absorption was investigated.

  9. Measurement of radiation and temperature of cathod spots in excimer laser discharge; Ekishima reza reiki hodennai ni fukumareru inkyoku kiten no kogakuteki kansoku to ondo no sokutei

    Energy Technology Data Exchange (ETDEWEB)

    Minamitani, Y.; Nakatani, H. [Mitsubishi Electric Corp., Tokyo (Japan)

    1996-08-20

    Excimer laser is used in various fields such as luminous source for steppers, annealing treatment, ablation process, nuclear fusion and so on. In this paper, the radiation timing and gas temperature of cathode spots, streamer discharges and glow discharges in KrF excimer are measured by observing the radiating spectra thereof. The following conclusions are obtained from the results of the present study. Cathode spots begin to radiate at about 20ns after the discharge initiation, then the first and second radiation peaks are observed respectively when the discharge current reversing after passing zero point and the reserved discharged current approaching zero point. Streamer discharge makes flashover between electrodes at the second radiation peak of cathode spots, while the glow discharges almost disappear when streamer discharges occurring. The temperatures of cathode spots and glow discharge as 5500K and 2600K respectively are almost constant and independent upon the discharging voltage of laser. 14 refs., 12 figs.

  10. FEM for modelling 193 nm excimer laser treatment of SiO{sub 2}/Si/Si{sub (1-x)}Ge{sub x} heterostructures on SOI substrates

    Energy Technology Data Exchange (ETDEWEB)

    Conde, J.C.; Chiussi, S.; Gontad, F.; Gonzalez, P. [Dpto. Fisica Aplicada, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, 36310 Vigo (Spain); Martin, E. [Dpto. de Mecanica, Maquinas, Motores Termicos y Fluidos, E.T.S.I.I. University of Vigo, Campus Universitario, Rua Maxwell s/n, 36310 Vigo (Spain)

    2011-03-15

    Research on epitaxial crystalline silicon (c-Si) and silicon-germanium (Si{sub 1-x}Ge{sub x}) alloys growth and annealing for microelectronic purposes, such as Micro- or Nano-Electro-Mechanical Systems (MEMS or NEMS) and Silicon-On-Nothing (SON) devices is continuously in progress. Laser assisted annealing techniques using commercial ArF Excimer Laser sources are based on ultra-rapid heating and cooling cycles induced by the 193 nm pulses of 20 ns, which are absorbed in the near surface region of the heterostructures. During and after the absorption of these laser pulses, complex physical processes appear that strongly depend on sample structure and applied laser pulse energy densities. The control of the experimental parameters is therefore a key task for obtaining high quality alloys. The Finite ElementsMethod (FEM) is a powerful tool for the optimization of such treatments, because it provides the spatial and temporal temperature fields that are produced by the laser pulses. In this work, we have used a FEM commercial software, to predict the temperatures gradients induced by ArF excimer laser over a wide energy densities range, 0.1<{phi}<0.4 J/cm{sup 2}, on different SiO{sub 2}/Si/Si{sub (1-x)}Ge{sub (x)} thin films deposited on SOI substrate. These numerical results allow us to predict the threshold energies needed to reach the melting point (MP) of the Si and SiGe alloy without oxidation of the thin films system. Therefore, it is possible to optimize the conditions to achieve high quality epitaxy films. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis).

    Science.gov (United States)

    Dippel, Eric J; Makam, Prakash; Kovach, Richard; George, Jon C; Patlola, Raghotham; Metzger, D Christopher; Mena-Hurtado, Carlos; Beasley, Robert; Soukas, Peter; Colon-Hernandez, Pedro J; Stark, Matthew A; Walker, Craig

    2015-01-01

    The purpose of this study was to evaluate the safety and efficacy of excimer laser atherectomy (ELA) with adjunctive percutaneous transluminal angioplasty (PTA) versus PTA alone for treating patients with chronic peripheral artery disease with femoropopliteal bare nitinol in-stent restenosis (ISR). Femoropopliteal stenting has shown superiority to PTA for lifestyle-limiting claudication and critical limb ischemia, although treating post-stenting artery reobstruction, or ISR, remains challenging. The multicenter, prospective, randomized, controlled EXCITE ISR (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis) trial was conducted across 40 U.S. centers. Patients with Rutherford Class 1 to 4 and lesions of target lesion length ≥4 cm, vessel diameter 5 to 7 mm were enrolled and randomly divided into ELA + PTA and PTA groups by a 2:1 ratio. The primary efficacy endpoint was target lesion revascularization (TLR) at 6-month follow up. The primary safety endpoint was major adverse event (death, amputation, or TLR) at 30 days post-procedure. Study enrollment was stopped at 250 patients due to early efficacy demonstrated at a prospectively-specified interim analysis. A total of 169 ELA + PTA subjects (62.7% male; mean age 68.5 ± 9.8 years) and 81 PTA patients (61.7% male; mean age 67.8 ± 10.3 years) were enrolled. Mean lesion length was 19.6 ± 12.0 cm versus 19.3 ± 11.9 cm, and 30.5% versus 36.8% of patients exhibited total occlusion. ELA + PTA subjects demonstrated superior procedural success (93.5% vs. 82.7%; p = 0.01) with significantly fewer procedural complications. ELA + PTA and PTA subject 6-month freedom from TLR was 73.5% versus 51.8% (p < 0.005), and 30-day major adverse event rates were 5.8% versus 20.5% (p < 0.001), respectively. ELA + PTA was associated with a 52% reduction in TLR (hazard ratio: 0.48; 95% confidence interval: 0.31 to 0.74). The EXCITE ISR trial is the first large, prospective, randomized study

  12. Lasers '89

    International Nuclear Information System (INIS)

    Harris, D.G.; Shay, T.M.

    1990-01-01

    This book covers the following topics: XUV, X-Ray and Gamma-Ray Lasers, excimer lasers, chemical lasers, nuclear pumped lasers, high power gas lasers, solid state lasers, laser spectroscopy. The paper presented include: Development of KrF lasers for fusion and Nuclear driven solid-state lasers

  13. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System.

    Science.gov (United States)

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-05-25

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction ( p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from -14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant ( p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments.

  14. The effect of excimer laser pretreatment on diffusion and activation of boron implanted in silicon

    International Nuclear Information System (INIS)

    Monakhov, E.V.; Svensson, B.G.; Linnarsson, M.K.; La Magna, A.; Italia, M.; Privitera, V.; Fortunato, G.; Cuscuna, M.; Mariucci, L.

    2005-01-01

    We have investigated the effect of excimer laser annealing (ELA) on transient enhanced diffusion (TED) and activation of boron implanted in Si during subsequent rapid thermal annealing (RTA). It is observed that ELA with partial melting of the implanted region causes reduction of TED in the region that remains solid during ELA, where the diffusion length of boron is reduced by a factor of ∼4 as compared to the as-implanted sample. This is attributed to several mechanisms such as liquid-state annealing of a fraction of the implantation induced defects, introduction of excess vacancies during ELA, and solid-state annealing of the defects beyond the maximum melting depth by the heat wave propagating into the Si wafer. The ELA pretreatment provides a substantially improved electrical activation of boron during subsequent RTA

  15. Acute effects of pulsed-laser irradiation on the arterial wall

    Science.gov (United States)

    Nakamura, Fumitaka; Kvasnicka, Jan; Lu, Hanjiang; Geschwind, Herbert J.; Levame, Micheline; Bousbaa, Hassan; Lange, Francoise

    1992-08-01

    Pulsed laser coronary angioplasty with an excimer or a holmium-yttrium-aluminum-garnet (Ho:YAG) laser may become an alternative treatment for patients with coronary artery disease. However, little is known about its acute consequences on the normal arterial wall. This study was designed to examine the acute histologic consequences of these two pulsed lasers on the arterial wall of normal iliac arteries in rabbits. Irradiation with each laser was performed in 15 normal iliac sites on eight male New Zealand white rabbits. The excimer laser was operated at 308 nm, 25 Hz, 50 mJ/mm2/pulse, and 135 nsec/pulse and the Ho:YAG laser was operated at 2.1 micrometers , 3/5 Hz, 400 mJ/pulse, and 250 microsecond(s) ec/pulse. The excimer and Ho:YAG laser were coupled into a multifiber wire-guided catheter of 1.4 and 1.5 mm diameter, respectively. The sites irradiated with excimer or Ho:YAG laser had the same kinds of histologic features, consisting of exfoliation of the endothelium, disorganization of internal elastic lamina, localized necrosis of vascular smooth muscle cells, and fissures in the medial layer. However, the sites irradiated with excimer laser had lower grading scores than those irradiated with Ho:YAG laser (p vascular injury.

  16. Plastic scintillators based on polymers with eliminated excimer forming

    Energy Technology Data Exchange (ETDEWEB)

    Adadurov, A.F., E-mail: adadurov@isma.kharkov.u [Institute for Scintillating Materials NAN of Ukraine, 60 Lenin Ave, 61001 Kharkov (Ukraine); Yelyseev, D.A.; Titskaya, V.D.; Lebedev, V.N.; Zhmurin, P.N. [Institute for Scintillating Materials NAN of Ukraine, 60 Lenin Ave, 61001 Kharkov (Ukraine)

    2011-05-15

    Plastic scintillators (PS) were made based on benzyl methacrylate and methyl-methacrylate P(BzMA + MMA) copolymer in which the excimer forming rate is by two order lesser than that in polystyrene-based polymer matrix. Studying of these PS light yield demonstrates the importance of migration processes comparing to excimer formation. It is found that to obtain PS with high scintillation efficiency it is necessary to use the polymer base (matrix) in which excimer forming is eliminated but the migration process along the chromophores is maximally favored. To explain the accelerated energy transfer between phenyl chromophores it is proposed to use a mechanism of exchange of that virtual excitons that can propagate along a one-dimensional back-bone of polymer molecule. Clearing the details of mechanism of interaction between chromophores of polymer molecules which is responsible for accelerated radiationless energy transfer enable will determine in future the way of effective plastic scintillators designing.

  17. Suppression of dewetting phenomena during excimer laser melting of thin metal films on SiO2

    International Nuclear Information System (INIS)

    Kline, J.E.; Leonard, J.P.

    2005-01-01

    Pulsed excimer laser irradiation has been used to fully melt 200 nm films of elemental Au and Ni on SiO 2 substrates. With the use of a capping layer of SiO 2 and line irradiation via projection optics, the typical liquid-phase dewetting processes associated with these metals on SiO 2 has been suppressed. In a series of experiments varying line widths and fluence, a process region is revealed immediately above the complete melting threshold for which the films remain continuous and smooth after melting and resolidification. Simple energetic arguments for mechanisms leading to initiation of dewetting support these observations, and a gas-mediated model is proposed to describe the process conditions that are necessary for the suppression of dewetting

  18. Modeling of excimer laser radiation induced defect generation in fluoride phosphate glasses

    International Nuclear Information System (INIS)

    Natura, U.; Ehrt, D.

    2001-01-01

    Fluoride phosphate (FP) glasses with low phosphate content are high-transparent in the deep ultraviolet (UV) range and attractive candidates for UV-optics. Their optical properties are complementary to fluoride crystals. The anomalous partial dispersion makes them desirable for optical lens designs to reduce the secondary spectrum. Their UV transmission is limited by trace impurities introduced by raw materials and decreases when exposed to UV-radiation (lamps, lasers). The experiments of the paper published previously in this journal were used in order to separate radiation induced absorption bands in the fluoride phosphate glass FP10. In this paper the generation mechanism of the phosphorus-oxygen related hole center POHC 2 is investigated in detail in glasses of various compositions (various phosphate and impurity contents) in order to predict the transmission loss in case of long-time irradiation. Experiments were carried out using ArF- and KrF-excimer lasers (ns-pulses). POHC 2 generation strongly depends on the phosphate content and on the content of Pb 2+ . A model was developed on these terms. Rate equations are formulated, incorporating the influence of the Pb 2+ -content on the defect generation, a two-step creation term including an energy transfer process and a one-photon bleaching term. This results in a set of coupled nonlinear differential equations. Absorption coefficients and lifetimes of the excited states were calculated as well. Experimental results compared well with the numerical analysis of the theoretical rate equations

  19. Gasochromic performance of WO{sub 3}-nanorod thin films fabricated with an ArF excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Yaacob, M. H. [RMIT University, Melbourne (Australia); Universiti Putra Malaysia, Selangor (Malaysia); Ou, J. Z.; Wlodarski, W. [RMIT University, Melbourne (Australia); Kim, C. S.; Lee, J. Y. [KAIST, Daejon (Korea, Republic of); Kim, Y. H. [KIST, Seoul (Korea, Republic of); Oh, C. M.; Dhakal, K. P.; Kim, J. Y.; Kang, J. H. [University of Incheon, Incheon (Korea, Republic of)

    2012-02-15

    Thin films with tungsten trioxide (WO{sub 3}) nanorods were fabricated by using an ArF pulsed laser deposition system. Because the ArF excimer laser operates at a very short wavelength of 193 nm, short enough to expect strong absorption of the photons in the semiconductor oxide targets, and because the clusters incoming to the substrates have high momentum, we could build thin films with good surface morphology. Highly homogeneous arrays of nanorods with sizes mostly in the range of 30 - 40 nm were observed. The absorbance response towards hydrogen (H{sub 2}) gas was investigated for a WO{sub 3} film coated with 25-A-thick palladium (Pd). The Pd/WO{sub 3}-nanorod thin films exhibited excellent gasochromic response when measured in the visible-NIR range (400 - 1000 nm). As low as 0.06% H{sub 2} concentration was clearly sensed. A significant reversible absorbance change and fast recovery (<2 min) were observed when the films were exposed to H{sub 2} at different concentrations.

  20. Corneal ablation depth readout of the MEL 80 excimer laser compared to Artemis three-dimensional very high-frequency digital ultrasound stromal measurements.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Gobbe, Marine

    2010-12-01

    To evaluate the accuracy of the ablation depth readout for the MEL 80 excimer laser (Carl Zeiss Meditec). Artemis 1 very high-frequency digital ultrasound measurements were obtained before and at least 3 months after LASIK in 121 eyes (65 patients). The Artemis-measured ablation depth was calculated as the maximum difference in stromal thickness before and after treatment. Laser in situ keratomileusis was performed using the MEL 80 excimer laser and the Hansatome microkeratome (Bausch & Lomb). The Aberration Smart Ablation profile was used in 56 eyes and the Tissue Saving Ablation profile was used in 65 eyes. All ablations were centered on the corneal vertex. Comparative statistics and linear regression analysis were performed between the laser readout ablation depth and Artemis-measured ablation depth. The mean maximum myopic meridian was -6.66±2.40 diopters (D) (range: -1.50 to -10.00 D) for Aberration Smart Ablation-treated eyes and -6.50±2.56 D (range: -1.34 to -11.50 D) for Tissue Saving Ablation-treated eyes. The MEL 80 readout was found to overestimate the Artemis-measured ablation depth by 20±12 μm for Aberration Smart Ablation and by 21±12 μm for Tissue Saving Ablation profiles. The accuracy of ablation depth measurement was improved by using the Artemis stromal thickness profile measurements before and after surgery to exclude epithelial changes. The MEL 80 readout was found to overestimate the achieved ablation depth. The linear regression equations could be used by MEL 80 users to adjust the ablation depth for predicted residual stromal thickness calculations without increasing the risk of ectasia due to excessive keratectomy depth as long as a suitable flap thickness bias is included. Copyright 2010, SLACK Incorporated.

  1. Development in high speed and high quality laser cutting process in fiber reinforced plastics; FRP no laser ni yoru kosoku, kohinshitsu setsudan gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Ishide, T.; Shirota, H.; Matsumoto, O. [Mitsubishi Heavy Industries, Ltd., Tokyo (Japan)

    1996-06-01

    Trimming was performed and studied by cutting KFRP, an epoxy matrix with Kevlar fiber woven thereinto, using various laser beams. The CO2 laser is capable of high-speed cutting but the product is low in quality. The surface of a cut by the YAG laser is not high in quality even with its peak output elevated. The thermally affected area is smaller under the excimer laser but it is low in cutting speed. The ablation properties of the excimer laser were investigated and the beam was shaped into a linear beam for another experiment, but it failed to attain the target speed of cutting. Next, a combination of excimer laser and CO2 laser was used for cutting. It was so designed that the preceding CO2 laser cuts the KFRP at a high speed to leave behind a carbonized layer, which is followed by a linear beam which vaporizes the carbonized layer for removal. An optical system is adopted for reshaping the excimer oscillated beam into a tube-like beam. Optical conditions were determined for a fluence value required for the removal of the carbonized layer. When the CO2 laser was set at 160W and the excimer laser at 20W, a 1mm-thick sheet was successfully cut at a speed of 16.7mm/sec. 3 refs., 7 figs.

  2. Some optical and electron microscope comparative studies of excimer laser-assisted and nonassisted molecular-beam epitaxically grown thin GaAs films on Si

    Science.gov (United States)

    Lao, Pudong; Tang, Wade C.; Rajkumar, K. C.; Guha, S.; Madhukar, A.; Liu, J. K.; Grunthaner, F. J.

    1990-01-01

    The quality of GaAs thin films grown via MBE under pulsed excimer laser irradiation on Si substrates is examined in both laser-irradiated and nonirradiated areas using Raman scattering, Rayleigh scattering, and by photoluminescence (PL), as a function of temperature, and by TEM. The temperature dependence of the PL and Raman peak positions indicates the presence of compressive stress in the thin GaAs films in both laser-irradiated and nonirradiated areas. This indicates incomplete homogeneous strain relaxation by dislocations at the growth temperature. The residual compressive strain at the growth temperature is large enough such that even with the introduction of tensile strain arising from the difference in thermal expansion coefficients of GaAs and Si, a compressive strain is still present at room temperature for these thin GaAs/Si films.

  3. Simulation of beam pointing stability on targeting plane of high power excimer laser system

    International Nuclear Information System (INIS)

    Wang Dahui; Zhao Xueqing; Zhang Yongsheng; Zheng Guoxin; Hu Yun; Zhao Jun

    2011-01-01

    Based on characteristics of image-relaying structure in high power excimer MOPA laser system, simulation and analysis software of targeting beam's barycenter stability was designed by using LABVIEW and MATLAB. Simulation was made to measured results of every optical component in laboratory environment. Simulation and validation of budget values for optical components was and optimization of error budget of system was accomplished via post-allocation for several times. It is shown that targeting beam's barycenter stability in the condition of current laboratory environment can't satisfy needs and index of high demand optical components can be allotted to 1.7 μrad when index of low demand optical components have some stability margin. These results can provide a guide to construction of system and design and machining of optical components and optimization of system. Optical components of laboratory on work can satisfy optimized distributed index, which reduce the demand of structure to some extent. (authors)

  4. Post-growth annealing of germanium-tin alloys using pulsed excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lanxiang; Wang, Wei; Zhou, Qian; Yeo, Yee-Chia, E-mail: yeo@ieee.org [Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117582 (Singapore); Pan, Jisheng; Zhang, Zheng [Institute of Materials Research and Engineering, A*STAR (Agency for Science, Technology and Research), Singapore 117602 (Singapore); Tok, Eng Soon [Department of Physics, National University of Singapore, Singapore 117551 (Singapore)

    2015-07-14

    We investigate the impact of pulsed excimer laser anneal on fully strained germanium-tin alloys (Ge{sub 1−x}Sn{sub x}) epitaxially grown on Ge substrate by molecular beam epitaxy. Using atomic force microscopy, X-ray diffraction, transmission electron microscopy, and X-ray photoelectron spectroscopy, the morphological and compositional evolution of Ge{sub 1−x}Sn{sub x} with Sn content up to 17% after annealing using various conditions is studied. Ge{sub 0.83}Sn{sub 0.17} samples annealed at 80 mJ/cm{sup 2} or 150 mJ/cm{sup 2} have no observable changes with respect to the as-grown sample. However, Ge{sub 0.83}Sn{sub 0.17} samples annealed at 250 mJ/cm{sup 2} or 300 mJ/cm{sup 2} have Sn-rich islands on the surface, which is due to Sn segregation in the compressively strained epitaxial film. For Ge{sub 0.89}Sn{sub 0.11}, significant Sn redistribution occurs only when annealed at 300 mJ/cm{sup 2}, indicating that it has better thermal stability than Ge{sub 0.83}Sn{sub 0.17}. A mechanism is proposed to explain the formation of Sn-rich islands and Sn-depleted regions.

  5. Excimer-mediated photoionization of covalently-linked diaryl compounds: Energy thresholds for excimer formation and excimer-assisted photoionization of jet-cooled bis (9-Fluorenyl) methane

    International Nuclear Information System (INIS)

    Lee, Jae Kwang; Kang, Heun Kag; Cho, Han Joung; Boo, Bong Hyun; Lim, Edward C.

    2001-01-01

    Diarylakanes capable of adopting a face-to face arrangement of the two aromatic rings are ideal systems in which to probe the excited-state dynamics leading to excimer formation and the role of the singlet excimer in the photoionization of covalently linked bichromophoric molecules. Bis (9-eluorenyl) methane, BFM, is a good example of such diaryl compounds. Boo and co-workers have shown that BFM exhibits excrimer fluorescence in solution at ambient temperatures. An Arrhenius plot of the temperature-dependent excimer formation rate yielded activation energy of about 15 kJ·mol -1 . It has been proposed that the activation energy is related to the barrier for transforming the initial S 1 geometry to the face-to face (sandwich-pair) geometry of the intramolecular singlet excimer. This is accord with the study of an intramolecular excimer formation in jet-cooled 1, 3-diphenylpropane (DPP), and that of an intramolecular exciplex formation in 1-(9-anthryl)-3-(4-N, N-dimethylaniline) propane, which indicate that the energy threshold for such conformational changes is about 11 kJ·mol -1 .

  6. Insight into excimer laser crystallization exploiting ellipsometry: Effect of silicon film precursor

    Energy Technology Data Exchange (ETDEWEB)

    Losurdo, Maria [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR and INSTM sez. Bari, Via Orabona 4, 70125 Bari (Italy)], E-mail: maria.losurdo@ba.imip.cnr.it; Giangregorio, Maria M.; Sacchetti, Alberto; Capezzuto, Pio; Bruno, Giovanni [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR and INSTM sez. Bari, Via Orabona 4, 70125 Bari (Italy); Mariucci, Luigi; Fortunato, Guglielmo [IFN-CNR, Via Cineto Romano, 42 - 00156 Rome (Italy)

    2007-07-16

    The optical diagnostic of spectroscopic ellipsometry is shown to be an effective tool to investigate the mechanism of excimer laser crystallization (ELC) of silicon thin films. A detailed spectroscopic ellipsometric investigation of the microstructures of polycrystalline Si films obtained on SiO{sub 2}/Si wafers by ELC of a-Si:H and nc-Si films deposited, respectively, by SiH{sub 4} plasma enhanced chemical vapor deposition (PECVD) and SiF{sub 4}-PECVD is presented. It is shown that ellipsometric spectra of the pseudodielectric function of polysilicon thin films allows to discern the three different ELC regimes of partial melting, super lateral growth and complete melting. Exploiting ellipsometry and atomic force microscopy, it is shown that ELC of nc-Si has very low energy density threshold of 95 mJ/cm{sup 2} for complete melting, and that re-crystallization to large grains of {approx} 2 {mu}m can be achieved by multi-shot irradiation at an energy density as low as 260 mJ/cm{sup 2} when using nc-Si when compared to 340 mJ/cm{sup 2} for the ELC of a-Si films.

  7. PRK by Er:YAG laser: in-vitro studies and first in-vivo experiences

    Science.gov (United States)

    Steiner, Rudolf W.; Leiacker, Richard; Russ, Detlef; Seiler, Theo

    1996-01-01

    Photorefractive keratectomy (PRK) is usually performed by an excimer laser at 193 nm wavelength. Ablatio of corneal tissue is, however, not only possible in the UV region of the optical spectrum but also in the IR where water is an excellent absorber. Therefore, an Er:YAG laser was used at 2.94 micrometer wavelength as an alternative laser light source to perform in vitro studies of corneal ablation and also first clinical experiments to correct myopia of patients with blind eyes.

  8. Excimer laser phototherapeutic keratectomy : Indications, results and its role in the Indian scenario

    Directory of Open Access Journals (Sweden)

    Rao Srinivas

    1999-01-01

    Full Text Available PURPOSE: To report indications, technique, and results of excimer phototherapeutic keratectomy (PTK, and describe possible reasons for the small numbers of such procedures performed in a referral institute in India. METHODS: Retrospective review of case records of 10 patients (11 eyes who underwent excimer PTK at our institute between February 1994 and September 1997. RESULTS: Corneal scars were the most common indication for treatment. Best-corrected visual acuity (BCVA improved in 6 eyes (mean: 2 lines of Snellen acuity. All eyes had BCVA > or = 6/12 after treatment. None of the patients experienced loss of BCVA after treatment. Unaided visual acuity improved in 3 eyes and decreased in 2 eyes. Change in spherical equivalent refraction > or = 1 diopter occurred in 77.8% of eyes after treatment. Treating central corneal scars resulted in a significant hyperopic shift in refraction. CONCLUSIONS: Excimer PTK is a safe and effective procedure for the treatment of superficial corneal opacities. Post-treatment ametropia may require further correction with optical aids. Inappropriate referrals, deep corneal scars, and cost of the procedure could have contributed to the small numbers of PTK performed at our institute. Improved understanding of procedural strengths and limitations could lead to increased use of this procedure, with satisfying results in selected patients.

  9. Stability of iodinated contrast media in UV-laser irradiation and toxicity of photoproducts

    International Nuclear Information System (INIS)

    Groenewaeller, E.F.; Kehlbach, R.; Claussen, C.D.; Duda, S.H.; Wahl, H.G.; Rodemann, H.P.

    1998-01-01

    Purpose: In XeCl-Excimer laser angioplasty, unintended and possibly harmful interaction of the UV-laser light and the contrast media may occur due to the high concentration of contrast medium proximal to the occlusion or subtotal stenosis. Methods: One ml of three nonionic monomeric contrast agents (iopromide, iomeprol, iopamidol), one nonionic dimetric (jotrolane), and one ionic monomeric (amidotrizoate) X-ray contrast agent were irradiated with a XeCl excimer laser (λ=308 nm, pulse duration 120 ns, 50 Hz) using a 9 French multifiber catheter (12 sectors). Up to 20 000 pulses (106 J) were applied. Using high performance liquid chromatography the amount of liberated iodide as well as the fraction of unchanged contrast media were measured. Cytotoxicity of the photoproducts was tested in a colony formation assay of human skin fibroblasts. The contrast agents were irradiated with 2000 pulses/ml (5.3 mJ/pulse; 10.6 J) and then added to the cell cultures for a period of three hours in a concentration of 10%. Results: Excimer laser irradiation induced iodide liberation of up to 3.3 mg iodide/ml. Up to 19% of the contrast agents changed their original molecular structure. Incubation of irradiated contrast agents resulted in a significantly decreased potential for colony formation (p values ranging from 0.0044 to 0.0102) with significantly higher toxicity of amidotrizoate and iomeprol in comparison to iopromide, iotrolan, and iopamidol. Discussion: Due to the cytotoxic photoproducts and the high level of liberated iodide, it is recommended to flush the artery with physiological saline solution before applying a pulsed excimer laser in human arterial obstructions in order to reduce the contrast agent concentration at the site of irradiation. (orig.) [de

  10. Excimer UV curing in printing

    International Nuclear Information System (INIS)

    Mehnert, R.

    1999-01-01

    It is the aim of this study to investigate the potential of 308 run excimer UV curing in web and sheet fed offset printing and to discuss its present status. Using real-time FTIR-ATR and stationary or pulsed monochromatic (313 nm) irradiation chemical and physical factors affecting the curing speed of printing inks such as nature and concentration of photo-initiators, reactivity of the ink binding system, ink thickness and pigmentation, irradiance in the curing plane, oxygen concentration and nitrogen inerting, multiple pulse exposure, the photochemical dark reaction and temperature dependence were studied. The results were used to select optimum conditions for excimer UV curing in respect to ink reactivity, nitrogen inerting and UV exposure and to build an excimer UV curing unit consisting of two 50 W/cm 308 run excimer lamps, power supply, cooling and inerting unit. The excimer UV curing devices were tested under realistic conditions on a web offset press zirkon supra forte and a sheet fed press Heidelberg GTO 52. Maximum curing speeds of 300 m/min in web offset and 8000 sheets per hour in sheet fed offset were obtained

  11. A general excimer signaling approach for aptamer sensors.

    Science.gov (United States)

    Wu, Cuichen; Yan, Ling; Wang, Chunming; Lin, Haoxue; Wang, Chi; Chen, Xi; Yang, Chaoyong James

    2010-06-15

    Simple, fast and direct analysis or monitoring of significant molecules in complex biological samples is important for many biological study, clinical diagnosis and forensic investigations. Herein we highlight a general method to tailor aptamer sequence into functional subunits to design target-induced light-switching excimer sensors for rapid, sensitive and selective detection of important molecules in complex biological fluids. Our approach is to split one single strand aptamer into two pieces and each terminally labeled with a pyrene molecule while maintaining their binding affinity to target molecules. In the presence of target molecules, two aptamer fragments are induced to self-assemble to form aptamer-target complex and bring two pyrene molecules into a close proximity to form an excimer, resulting in fluorescent switching from approximately 400 nm to 485 nm. With an anti-cocaine sensor, as low as 1 microM of cocaine can be detected using steady-state fluorescence assays and more importantly low picomole level of target can be directly visualized with naked eyes. Because the excimer has a long fluorescence lifetime, time-resolved measurements were used to directly detect as low as 5 microM cocaine in urine samples quantitatively without any sample pretreatment. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Single application on iris localization technology in excimer laser for astigmatism

    Directory of Open Access Journals (Sweden)

    Jun-Hua Hao

    2014-06-01

    Full Text Available AIM:To discuss the single application on iris localization technology in excimer laser for the treatment of astigmatism. METHODS:Totally 203 cases(406 eyesof laser in situ keratomileusis(LASIKin the treatment of compound myopic astigmatism patients were operated from November 2011 to November 2012 in our hospital. They were divided into two groups. One was observation group using iris localization and the other was control group using routine operation. Patients in the observation group of 100 cases(200 eyes, aged 18-43 years old, spherical diopter was -1.25 to -8.75D, astigmatism was -1.0 to -3.25D. In control group, 103 patients(206 eyes, aged 19-44 years old, spherical diopter was -1.75-9.50D, astigmatism was -1.0 to -3.25D. The patients in the observation group before the application of WaveScan aberrometer check for iris image, spherical lens, cylindrical lens and astigmatism axis data operation, only single application of iris location, without using wavefront aberration guided technology, laser cutting patterns for conventional LASIK model, spherical, cylindrical mirror and astigmatism axis data source to preoperative wavefront aberration results. The control group received routine LASIK. It was applicated comprehensive optometry optometry respectively to examine astigmatism and axial, based on the computer analysis during the preoperative, 1wk after the operation, and 6mo. Analysis of using SPSS 17 statistical software, it was independent-sample t test between the two groups of residual astigmatism and astigmatism axis. RESULTS:Postoperative residual astigmatism, the observation group was significantly better than the control group. Astigmatism axial measurement after operation, the observation group was significantly less than that of the control group. Postoperative visual acuity at 6mo, the observation group was better than that of the control group. The difference was statistically significant. CONCLUSION: For patients who cannot

  13. Laser/Light Therapy for Birthmarks

    Science.gov (United States)

    ... for Every Season How to Choose the Best Skin Care Products In This Section Dermatologic Surgery What is dermatologic ... for Every Season How to Choose the Best Skin Care Products Laser/Light Therapy for Birthmarks In laser/light ...

  14. UV laser micromachining of ceramic materials: formation of columnar topographies

    International Nuclear Information System (INIS)

    Oliveira, V.; Vilar, R.; Conde, O.

    2001-01-01

    Laser machining is increasingly appearing as an alternative for micromachining of ceramics. Using ceramic materials using excimer lasers can result in smooth surfaces or in the formation of cone-like or columnar topography. Potential applications of cone-shaped or columnar surface topography include, for example, light trapping in anti-reflection coatings and improvement of adhesion bonding between ceramic materials. In this communication results of a comparative study of surface topography change during micromachining of several ceramic materials with different ablation behaviors are reported. (orig.)

  15. Preparation of the La0.8Sr0.2MnO3 films on STO and LAO substrates by excimer laser-assisted metal organic deposition using the KrF laser

    International Nuclear Information System (INIS)

    Tsuchiya, T.; Daoudi, K.; Manabe, T.; Yamaguchi, I.; Kumagai, T.

    2007-01-01

    La 0.8 Sr 0.2 MnO 3 films were prepared on SrTiO 3 (STO) and LaAlO 3 (LAO) substrates using excimer laser-assisted metal organic deposition (ELAMOD). For the LAO substrate, no epitaxial La 0.8 Sr 0.2 MnO 3 film was obtained by laser irradiation in the fluence range from 60 to 110 mJ/cm 2 with heating at 500 deg. C. On the other hand, an epitaxial La 0.8 Sr 0.2 MnO 3 film on the STO substrate was formed by laser irradiation in the fluence range from 60 to 100 mJ/cm 2 with heating at 500 deg. C. To optimize the electrical properties for an IR sensor, the effects of the laser fluence, the irradiation time and the film thickness on the temperature dependence of the resistance and temperature coefficient of resistance (TCR: defined as 1/R.(dR/dT)) of the LSMO films were investigated. An LSMO film on the STO substrate that showed the maximum TCR of 3.9% at 265 K was obtained by the ELAMOD process using the KrF laser

  16. Contrasting the beam interaction characteristics of selected lasers with a partially stabilized zirconia bio-ceramic

    International Nuclear Information System (INIS)

    Lawrence, J.

    2002-01-01

    Differences in the beam interaction characteristics of a CO 2 laser, a Nd:YAG laser, a high power diode laser (HPDL) and an excimer laser with a partially stabilized zirconia bio-ceramic have been studied. A derivative of Beer-Lambert's law was applied and the laser beam absorption lengths of the four lasers were calculated as 33.55x10 -3 cm for the CO 2 laser, 18.22x10 -3 cm for the Nd : YAG laser, 17.17x10 -3 cm for the HPDL and 8.41x10 -6 cm for the excimer laser. It was determined graphically that the fluence threshold values at which significant material removal was effected by the CO 2 laser, the Nd:YAG laser, the HPDL and the excimer laser were 52 J cm -2 , 97 J cm -2 , 115 J cm -2 and 0.48 J cm -2 , respectively. The thermal loading value for the CO 2 laser, the Nd : YAG laser, the HPDL and the excimer laser were calculated as being 1.55 kJ cm -3 , 5.32 kJ cm 3 , 6.69 kJ cm -3 and 57.04 kJ cm -3 , respectively. (author)

  17. Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System

    International Nuclear Information System (INIS)

    Gentile, C.A.; Fan, H.M.; Hartfield, J.W.; Hawryluk, R.J.; Hegeler, F.; Heitzenroeder, P.J.; Jun, C.H.; Ku, L.P.; LaMarche, P.H.; Myers, M.C.; Parker, J.J.; Parsells, R.F.; Payen, M.; Raftopoulos, S.; Sethian, J.D.

    2002-01-01

    The Princeton Plasma Physics Laboratory (PPPL), in collaboration with the Naval Research Laboratory (NRL), is currently investigating various novel materials (single crystal silicon, , and ) for use as electron-beam transmission windows in a KrF excimer laser system. The primary function of the window is to isolate the active medium (excimer gas) from the excitation mechanism (field-emission diodes). Chosen window geometry must accommodate electron energy transfer greater than 80% (750 keV), while maintaining structural integrity during mechanical load (1.3 to 2.0 atm base pressure differential, approximate 0.5 atm cyclic pressure amplitude, 5 Hz repetition rate) and thermal load across the entire hibachi area (approximate 0.9 W · cm superscript ''-2''). In addition, the window must be chemically resistant to attack by fluorine free-radicals (hydrofluoric acid, secondary). In accordance with these structural, functional, and operational parameters, a 22.4 mm square silicon prototype window, coated with 500 nm thin-film silicon nitride (Si 3 N 4 ), has been fabricated. The window consists of 81 square panes with a thickness of 0.019 mm ± 0.001 mm. Stiffened (orthogonal) sections are 0.065 mm in width and 0.500 mm thick (approximate). Appended drawing (Figure 1) depicts the window configuration. Assessment of silicon (and silicon nitride) material properties and CAD modeling and analysis of the window design suggest that silicon may be a viable solution to inherent parameters and constraints

  18. Thermonuclear fusion plasma produced by lasers

    International Nuclear Information System (INIS)

    Yamanaka, C.; Yokoyama, M.; Nakai, S.; Sasaki, T.; Yoshida, K.; Matoba, M.; Yamabe, C.; Tschudi, T.; Yamanaka, T.; Mizui, J.; Yamaguchi, N.; Nishikawa, K.

    1975-01-01

    Recently, much attention has been focused on laser fusion schemes using high-density plasmas produced by implosion. Scientific-feasibility laser-fusion experiments are now in time. But the physics of interaction between laser and plasma, the high-compression technique and the development of high-power lasers are still important problems to be solved if laser fusion is to make some progress. In the field of laser-plasma coupling, experiments were carried out in which hydrogen and deuterium sticks were bombarded by laser beams; in these experiments, a glass-laser system, LETKKO-I, with an energy of 50 J in a nanosecond pulse, and a double-discharge TEA CO 2 laser system with an energy of 100 J in a 100-ns pulse were used. A decrease in reflectivity occurred at a laser intensity one order of magnitude higher than the parametric-instability threshold. Self-phase modulation of scattered light due to modulational instability was found. A Brillouin-backscattering isotope effect due to the hydrogen and deuterium plasma has also been observed in the red-side part of the SHG-light. Preliminary compression experiments have been carried out using a glass-laser system LETKKO-II, with an energy of 250-1000 J in a ns-pulse. A hologram has been used to study shock waves in the plasma due to the SHG-light converted from the main laser beam. Development of high-power lasers has been promoted, such as disc-glass lasers, E-beam CO 2 lasers and excimer lasers. (author)

  19. F2 excimer laser (157 nm) radiation modification and surface ablation of PHEMA hydrogels and the effects on bioactivity: Surface attachment and proliferation of human corneal epithelial cells

    International Nuclear Information System (INIS)

    Zainuddin; Chirila, Traian V.; Barnard, Zeke; Watson, Gregory S.; Toh, Chiong; Blakey, Idriss; Whittaker, Andrew K.; Hill, David J.T.

    2011-01-01

    Physical and chemical changes at the surface of poly(2-hydroxyethyl methacrylate) (PHEMA) hydrogels modified by ablation with an F 2 excimer laser were investigated experimentally. An important observation was that only the outer exposed surface layers of the hydrogel were affected by the exposure to 157 nm radiation. The effect of the surface changes on the tendency of cells to adhere to the PHEMA was also investigated. A 0.5 cm 2 area of the hydrogel surfaces was exposed to laser irradiation at 157 nm to fluences of 0.8 and 4 J cm -2 . The changes in surface topography were analysed by light microscopy and atomic force microscopy, while the surface chemistry was characterized by attenuated total reflection infrared and X-ray photoelectron spectroscopies. Cell-interfacial interactions were examined based on the proliferation of human corneal limbal epithelial (HLE) cells cultured on the laser-modified hydrogels, and on the unexposed hydrogels and tissue culture plastic for comparison. It was observed that the surface topography of laser-exposed hydrogels showed rippled patterns with a surface roughness increasing at the higher exposure dose. The changes in surface chemistry were affected not only by an indirect effect of hydrogen and hydroxyl radicals, formed by water photolysis, on the PHEMA, but also by the direct action of laser radiation on PHEMA if the surface layers of the gel become depleted of water. The laser treatment led to a change in the surface characteristics, with a lower concentration of ester side-chains and the formation of new oxygenated species at the surface. The surface also became more hydrophobic. Most importantly, the surface chemistry and the newly created surface topographical features were able to improve the attachment, spreading and growth of HLE cells.

  20. Excimer Laser Phototherapeutic Keratectomy for the Treatment of Clinically Presumed Fungal Keratitis

    Directory of Open Access Journals (Sweden)

    Liang-Mao Li

    2014-01-01

    Full Text Available This retrospective study was to evaluate treatment outcomes of excimer laser phototherapeutic keratectomy (PTK for clinically presumed fungal keratitis. Forty-seven eyes of 47 consecutive patients underwent manual superficial debridement and PTK. All corneal lesions were located in the anterior stroma and were resistant to medication therapy for at least one week. Data were collected by a retrospective chart review with at least six months of follow-up data available. After PTK, infected corneal lesions were completely removed and the clinical symptoms resolved in 41 cases (87.2%. The mean ablation depth was 114.39±45.51 μm and diameter of ablation was 4.06±1.07 mm. The mean time for healing of the epithelial defect was 8.8±5.6 days. Thirty-four eyes (82.9% showed an improvement in best spectacle-corrected visual acuity of two or more lines. PTK complications included mild to moderate corneal haze, hyperopic shift, irregular astigmatism, and thinning cornea. Six eyes (12.8% still showed progressed infection, and conjunctival flap covering, amniotic membrane transplantation, or penetrating keratoplasty were given. PTK is a valuable therapeutic alternative for superficial infectious keratitis. It can effectively eradicate lesions, hasten reepithelialization, and restore and preserve useful visual function. However, the selection of surgery candidates should be conducted carefully.

  1. Reaction analysis of initial oxidation of silicon by UV-light-excited ozone and the application to rapid and uniform SiO2 film growth

    International Nuclear Information System (INIS)

    Tosaka, Aki; Nonaka, Hidehiko; Ichimura, Shingo; Nishiguchi, Tetsuya

    2007-01-01

    UV-light-excited O 3 prepared by irradiation of nearly 100% pure O 3 with a KrF excimer laser (λ=248 nm, irradiated area=30x10 mm 2 ) was utilized for low-temperature Si oxidation. The initial oxidation rate was determined, and the activation energy was shown to be almost zero (0.049 eV). To clarify the optimum oxidation conditions, the dependence of the SiO 2 film growth rate on the total photon number and the photon density was investigated. The evolution of O 3 density after UV-light irradiation was experimentally measured, and the O( 1 D) density change is discussed. O( 1 D) density changes are successfully explained by using a second-order reaction model, indicating that a pulse supply of oxygen atoms is essential in the initial oxidation process. The uniform oxidation of 8 in. Si wafer has been carried out using a wafer-transfer type chamber by irradiating the wafer with KrF excimer laser light expanded linearly to the wafer width by a concave lens

  2. Laser plasmas as x-ray sources for lithographic imaging of submicron structures

    International Nuclear Information System (INIS)

    Bijkerk, F.; van Dorssen, G.E.; van der Wiel, M.J.

    1988-01-01

    Laser radiation can be used efficiently to generate x-rays for lithographic imaging of submicron patterns, e.g., for VLSI device fabrication. Due to their short wavelength and high average power, excimer lasers show much potential for this application. Results are presented of scaling studies for high repetition rate excimer laser application, using the frequency doubled output of a low repetition rate Nd:YAG/Glass laser. Spectral and spatial characteristics of x-ray emission of the laser plasma are shown. The power density in the laser focus was 3 x 10 12 W/cm 2 . With this source Si x-ray masks with submicron Au absorber profiles are imaged into high sensitivity x-ray photoresist. For the exposures 80 laser shots sufficed to yield high quality submicron structures. Extrapolation of the results to a high power excimer laser reduces the exposure time of the photoresists to several seconds, enabling a wafer throughput at an industrial level

  3. Characterization of the excimers of poly(N-vinylcarbazole) using TRANES

    International Nuclear Information System (INIS)

    Ghosh, Debanjana; Chattopadhyay, Nitin

    2011-01-01

    Time-resolved emission spectra (TRES) and time-resolved area normalized emission spectra (TRANES) are exploited to characterize the excimers of poly(N-vinylcarbazole) (PNVC) in toluene and water. The time-resolved study together with the steady state measurements, decipher the fluorescence of the system containing pendant carbazole moieties in the polymer backbone unambiguously. Isoemissive point in the TRANES establishes that there are only two excimers of PNVC, the partially overlapped excimer emitting at high energy and the sandwich type excimer emitting at lower energy, and they are formed exclusively in the photoexcited state. The study substantiates an equilibrium between the two excimers. - Graphical Abstract: Highlights: → TRES and TRANES are exploited to decipher the emission of PNVC in toluene and water. → The emission comes from two excimers: partially overlapped and sandwich type. → TRANES shows single isoemissive point establishing presence of two excimers only. → Sandwich excimer is formed from the partially overlapped one in the excited state. → Existence of an equilibrium is established.

  4. New laser research and development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    New types of lasers must be developed to provide the desired energy per pulse, pulse length, pulse shape, wavelength, and efficiency for laser-fusion applications. This advanced laser research has focused on rare-gas oxides and on Hg 2 excimers

  5. Diode laser probe of CO2 vibrational excitation produced by collisions with hot deuterium atoms from the 193 nm excimer laser photolysis D2S

    International Nuclear Information System (INIS)

    O'Neill, J.A.; Cai, J.Y.; Flynn, G.W.; Weston, R.E. Jr.

    1986-01-01

    The 193 nm excimer laser photolysis of D 2 S in D 2 S/CO 2 mixtures produces fast deuterium atoms (E/sub TR/approx.2.2 eV) which vibrationally excite CO 2 molecules via inelastic translation--vibration/rotation (T--V/R) energy exchange processes. A high resolution (10 -3 cm -1 ) cw diode laser probe was used to monitor the excitation of ν 3 (antisymmetric stretch) and ν 2 (bend) vibrations in CO 2 . The present results are compared with previous experiments involving hot hydrogen atom excitation of CO 2 in H 2 S/CO 2 mixtures as well as with theoretical calculations of the excitation probability. The probability for excitation of a ν 3 quantum in CO 2 is about 1%--2% per gas kinetic D/CO 2 collision. Bending (ν 2 ) quanta are produced about eight times more efficiently than antisymmetric stretching (ν 3 ) quanta. The thermalization rate for cooling hot D atoms below the threshold for production of a ν 3 vibrational quantum corresponds to less than 2 D*/D 2 S collisions or 15 D*/CO 2 collisions

  6. Excimer laser ablation of the cornea

    Science.gov (United States)

    Pettit, George H.; Ediger, Marwood N.; Weiblinger, Richard P.

    1995-03-01

    Pulsed ultraviolet laser ablation is being extensively investigated clinically to reshape the optical surface of the eye and correct vision defects. Current knowledge of the laser/tissue interaction and the present state of the clinical evaluation are reviewed. In addition, the principal findings of internal Food and Drug Administration research are described in some detail, including a risk assessment of the laser-induced-fluorescence and measurement of the nonlinear optical properties of cornea during the intense UV irradiation. Finally, a survey is presented of the alternative laser technologies being explored for this ophthalmic application.

  7. High-energy krypton fluoride lasers for inertial fusion.

    Science.gov (United States)

    Obenschain, Stephen; Lehmberg, Robert; Kehne, David; Hegeler, Frank; Wolford, Matthew; Sethian, John; Weaver, James; Karasik, Max

    2015-11-01

    Laser fusion researchers have realized since the 1970s that the deep UV light from excimer lasers would be an advantage as a driver for robust high-performance capsule implosions for inertial confinement fusion (ICF). Most of this research has centered on the krypton-fluoride (KrF) laser. In this article we review the advantages of the KrF laser for direct-drive ICF, the history of high-energy KrF laser development, and the present state of the art and describe a development path to the performance needed for laser fusion and its energy application. We include descriptions of the architecture and performance of the multi-kilojoule Nike KrF laser-target facility and the 700 J Electra high-repetition-rate KrF laser that were developed at the U.S. Naval Research Laboratory. Nike and Electra are the most advanced KrF lasers for inertial fusion research and energy applications.

  8. Optics, light and lasers

    CERN Document Server

    Meschede, Dieter

    2008-01-01

    Starting from the concepts of classical optics, Optics, Light and Lasers introduces in detail the phenomena of linear and nonlinear light matter interaction, the properties of modern laser sources, and the concepts of quantum optics. Several examples taken from the scope of modern research are provided to emphasize the relevance of optics in current developments within science and technology. The text has been written for newcomers to the topic and benefits from the author's ability to explain difficult sequences and effects in a straightforward and easily comprehensible way. To this second, c

  9. Clinical results of excimer laser photorefractive keratectomy: a multicenter study of 265 eyes.

    Science.gov (United States)

    Aron-Rosa, D S; Colin, J; Aron, B; Burin, N; Cochener, B; Febraro, J L; Gallinaro, C; Ganem, S; Valdes, R

    1995-11-01

    Efficacy, predictability, and safety of excimer laser photorefractive keratectomy were evaluated at centers in Paris and Brest, France. Photoablation was performed with the VISX laser on 265 eyes (151 at the Paris center and 114 at the Brest center). The eyes were clinically and statistically evaluated over a six month follow-up. Initial myopia ranged from -0.7 to -19.4 diopters (D) (mean spherical equivalent [SE] -5.9 D) in the Paris center and from -0.9 to -14.5 D (SE -4.5 D) in the Brest center. At both centers, the mean uncorrected visual acuity was worse than 20/200; over 90% of cases in each center had a best uncorrected visual acuity of 20/100 or worse. Results are reported globally and for subgroups of myopia: Group A, SE better than or equal to -3.0 D; Group B, SE worse than -3.0 D and better than or equal to -7.0 D; Group C, SE worse than -7.0 D. Uncorrected visual acuity was significantly improved in the patients followed for six months; 64% of Paris cases and 62% of Brest cases obtained an uncorrected visual acuity of 20/40 or better. Predictability of the treatment was good; 67% of Paris eyes and 74% of Brest eyes were less than 1.0 D from the intended correction after six months. The data suggest that the initial myopia affected the efficacy and predictability of the treatment; results in the mild to moderate myopia eyes were significantly better than results in the severe myopia eyes. One case of visual acuity regression (less than one line) was observed in the two groups. This was associated with corneal haze of moderate intensity.

  10. Fiscal 2000 survey report. Research on laser-aided photolysis of environmental pollutant in liquid phase system; 2000 nendo ekisokei ni okeru kankyo osen busshitsu no laser hikari bunkai gijutsu ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Experiments were conducted on laser-aided decomposition and removal of chemical substances in liquid phase systems on the assumption that there existed chemical pollutants in wastewater or water after washing burned ash. The aim of the research was to split carbon-chlorine bonds and break benzene rings, the two being the cause of harmfulness, and experiments were conducted using chlorophenol. The photolytic lasers were ArF excimer laser and KrF excimer laser. It was found that the reduction rate of chlorophenol in a water solution under excimer laser irradiation was 1.7 times higher under KrF laser than under ArF laser. For mediums other than water, isopropanol was used, more convenient than chlorophenol in separating organic pollutants from burned ash and the like. In this case, organochlorine compounds were generated at the beginning, but they disappeared when irradiation was prolonged. It was demonstrated that the laser-aided environmental cleaning technology would find a very wide scope of application as an effective photolytic means. (NEDO)

  11. Threshold Characteristics of Slow-Light Photonic Crystal Lasers

    DEFF Research Database (Denmark)

    Xue, Weiqi; Yu, Yi; Ottaviano, Luisa

    2016-01-01

    The threshold properties of photonic crystal quantum dot lasers operating in the slow-light regime are investigated experimentally and theoretically. Measurements show that, in contrast to conventional lasers, the threshold gain attains a minimum value for a specific cavity length. The experimental...... results are explained by an analytical theory for the laser threshold that takes into account the effects of slow light and random disorder due to unavoidable fabrication imperfections. Longer lasers are found to operate deeper into the slow-light region, leading to a trade-off between slow-light induced...

  12. ArF excimer laser modulation of TNF-alpha and gelatinase B in NIH 3T3 cells; Modulation de l`expression du TNF-alpha et de la gelatinase B, apres irradiation de fibroblastes NIH 3T3 par un laser a excimeres a 193 NM

    Energy Technology Data Exchange (ETDEWEB)

    Naudy-Vives, C.; Courant, D.; Perot, J.C.; Garcia, J.; Fretier, P.; Court, L.; Dormont, D.

    1995-12-31

    The effects on TNF-alpha and gelatinase B activity in mammalian cells induced by 193 nm argon fluoride excimer laser have been investigated. The data show that a secretion of 92 kDa type IV collagenase and TNF-alpha were increased in cell culture supernatants. Moreover, the 193 nm laser radiation produces a decrease of cell proliferation and an increase of cell activation 8 hours after irradiation. The total protein amount increases with the delivered dose. Same, but less effects were obtained after exposure to a conventional UV lamp at 254 nm. (author). 8 refs.

  13. Laser materials processing with diode lasers

    OpenAIRE

    Li, Lin; Lawrence, Jonathan; Spencer, Julian T.

    1996-01-01

    Laser materials processing is currently dominated by CO2, Nd-YAG and Excimer lasers. Continuous advances in semiconductor laser technology over the last decade have increased the average power output of the devices annualy by two fold, resulting in the commercial availability of the diode lasers today with delivery output powers in excess of 60W in CW mode and 5kW in qasi-CW mode. The advantages of compactness, high reliability, high efficiency and potential low cost, due to the mass producti...

  14. Efficient and stable laser-driven white lighting

    Directory of Open Access Journals (Sweden)

    Kristin A. Denault

    2013-07-01

    Full Text Available Laser-based white lighting offers a viable option as an efficient and color-stable high-power solid-state white light source. We show that white light generation is possible using blue or near-UV laser diodes in combination with yellow-emitting cerium-substituted yttrium aluminum garnet (YAG:Ce or a mixture of red-, green-, and blue-emitting phosphors. A variety of correlated color temperatures (CCT are achieved, ranging from cool white light with a CCT of 4400 K using a blue laser diode to a warm white light with a CCT of 2700 K using a near-UV laser diode, with respective color rendering indices of 57 and 95. The luminous flux of these devices are measured to be 252 lm and 53 lm with luminous efficacies of 76 lm/W and 19 lm/W, respectively. An estimation of the maximum efficacy of a device comprising a blue laser diode in combination with YAG:Ce is calculated and the results are used to optimize the device.

  15. Simple laser-driven, metal photocathodes as cold, high-current electron sources

    International Nuclear Information System (INIS)

    Saunders, J.D.; Ringler, T.J.; Builta, L.A.; Kauppila, T.J.; Moir, D.C.; Downey, S.W.

    1987-01-01

    Recent developments in excimer laser design have made near ultraviolet light intensities of several MWcm 2 possible in unfocused beams. These advances and recent experiments indicate that high-current, simple-metal photoemissive electron guns are now feasible. Producing more than 50 Acm 2 of illuminated cathode surface, the guns could operate at vacuums of 10 -6 torr with no complicated system components inside the vacuum enclosure. The electron beam produced by such photoemission guns would have very low emittance and high brightness. This beam would also closely follow the temporal characteristics of the laser pulse, making fast risetime, ultrashort electron beam pulses possible

  16. Laser and intense pulsed light hair removal technologies

    DEFF Research Database (Denmark)

    Haedersdal, M; Beerwerth, F; Nash, J F

    2011-01-01

    Light-based hair removal (LHR) is one of the fastest growing, nonsurgical aesthetic cosmetic procedures in the United States and Europe. A variety of light sources including lasers, e.g. alexandrite laser (755 nm), pulsed diode lasers (800, 810 nm), Nd:YAG laser (1064 nm) and broad-spectrum intense...

  17. Comparación de la medición del grosor corneal central medido con el paquímetro incluido en el Wavelight® Ex500 Excimer Laser y el tomógrafo de cámara de Scheimpflug Pentacam® en sujetos sanos

    Directory of Open Access Journals (Sweden)

    Manuel Garza León

    2017-01-01

    Conclusiones: Nuestros resultados demuestran que el paquímetro incluido en el Wavelight® Ex500 Excimer Laser es una buena alternativa para la medición del grosor corneal central al Pentacam® en pacientes sanos.

  18. Applying low-energy multipulse excimer laser annealing to improve charge retention of Au nanocrystals embedded MOS capacitors

    International Nuclear Information System (INIS)

    Shen, Kuan-Yuan; Chen, Hung-Ming; Liao, Ting-Wei; Kuan, Chieh-Hsiung

    2015-01-01

    The low-energy multipulse excimer laser annealing (LEM-ELA) is proposed to anneal the nanostructure of nanocrystal (NC) embedded in a SiO 2 thin film without causing atomic diffusion and damaging the NCs, since the LEM-ELA combining the advantages of laser annealing and UV curing features rapid heating and increasing oxide network connectivity. A Fourier transform infrared spectroscopy (FTIR) characterization of SiO 2 thin films annealed using LEM-ELA indicated that the quality was improved through the removal of water-related impurities and the reconstruction of the network Si–O–Si bonds. Then, LEM-ELA was applied to a SiO 2 thin film embedded with Au NCs, which were fabricated as MOS capacitors. The charge retention was greatly improved and the percentage of retained charges was about 10% after 3  ×  10 8  s. To investigate and differentiate the effects of LEM-ELA on charges stored in both oxide traps and in the Au NCs, a double-mechanism charge relaxation analysis was performed. The results indicated that the oxide traps were removed and the confinement ability of Au NCs was enhanced. The separated memory windows contributed from the charges in Au NCs and those in oxide traps were obtained and further confirmed that the LEM-ELA removed oxide traps without damaging the Au NCs. (paper)

  19. Excimer laser development for fusion

    International Nuclear Information System (INIS)

    Giovanielli, D.

    1985-01-01

    The future utility of inertial confinement fusion requires a new driver. Successful experiments coupling laser energy to targets, and our understanding of fuel capsule behavior strongly suggest that a laboratory thermonuclear source is attainable and power production may be considered if a suitable driver with high efficiency, high repetition rate, and most importantly, low capital cost, can be identified. No adequate driver exists today; however, the krypton fluoride laser holds great promise. By the end of this decade, driver development can be brought to the point that a technically justifiable choice can be made for the future direction of ICF

  20. Future Solid State Lighting using LEDs and Diode Lasers

    DEFF Research Database (Denmark)

    Petersen, Paul Michael

    2014-01-01

    applications. Within the coming years, it is expected that the efficiency of blue laser diodes will approach the efficiency of infrared diode lasers. This will enable high efficiency white light generation with very high lumen per watt values. SSL today is mainly based on phosphor converted blue light emitting......Lighting accounts for 20% of all electrical energy usage. Household lighting and commercial lighting such as public and street lighting are responsible for significant greenhouse gas emissions. Therefore, currently many research initiatives focus on the development of new light sources which shows...... significant savings. Solid state lighting (SSL) based on LEDs is today the most efficient light source for generation of high quality white light. Diode lasers, however, have the potential of being more efficient than LEDs for the generation of white light. A major advantage using diode lasers for solid state...

  1. Ablation of polymers by ultraviolet pulsed laser

    International Nuclear Information System (INIS)

    Brezini, A.; Benharrats, N.

    1993-08-01

    The surface modifications of different polymers treated by far UV-Excimer laser (λ = 193mn, 248, 308nm) are analysed by X-Ray Photoelectrons Spectroscopy. The main feature observed depends strongly on the absorption coefficients. For the high absorbing polymers such (PVC, PS, PI,...) the mechanism of the UV-Excimer Laser interaction appears to be governed by an ablative photodecomposition process (APD) with an APD threshold. In the other limit, i.e. low absorbing polymer the interaction leads to a photothermal process. (author). 51 refs, 24 figs, 7 tabs

  2. 193nm high power lasers for the wide bandgap material processing

    Science.gov (United States)

    Fujimoto, Junichi; Kobayashi, Masakazu; Kakizaki, Koji; Oizumi, Hiroaki; Mimura, Toshio; Matsunaga, Takashi; Mizoguchi, Hakaru

    2017-02-01

    Recently infrared laser has faced resolution limit of finer micromachining requirement on especially semiconductor packaging like Fan-Out Wafer Level Package (FO-WLP) and Through Glass Via hole (TGV) which are hard to process with less defect. In this study, we investigated ablation rate with deep ultra violet excimer laser to explore its possibilities of micromachining on organic and glass interposers. These results were observed with a laser microscopy and Scanning Electron Microscope (SEM). As the ablation rates of both materials were quite affordable value, excimer laser is expected to be put in practical use for mass production.

  3. High incidence of rainbow glare after femtosecond laser assisted-LASIK using the upgraded FS200 femtosecond laser.

    Science.gov (United States)

    Zhang, Yu; Chen, Yue-Guo

    2018-03-05

    To compare the incidence of rainbow glare (RG) after femtosecond laser assisted-LASIK (FS-LASIK) using the upgraded FS200 femtosecond laser with different flap cut parameter settings. A consecutive series of 129 patients (255 eyes) who underwent FS-LASIK for correcting myopia and/or astigmatism using upgraded WaveLight FS200 femtosecond laser with the original settings was included in group A. Another consecutive series of 129 patients (255 eyes) who underwent FS-LASIK using upgraded WaveLight FS200 femtosecond laser with flap cut parameter settings changed (decreased pulse energy, spot and line separation) was included in group B. The incidence and fading time of RG, confocal microscopic image and postoperative clinical results were compared between the two groups. There were no differences between the two groups in age, baseline refraction, excimer laser ablation depth, postoperative uncorrected visual acuity and refraction. The incidence rate of RG in group A (35/255, 13.73%) was significantly higher than that in group B (4/255, 1.57%) (P  0.05).The confocal microscopic images showed wider laser spot spacing in group A than group B. The incidence of RG was significantly correlated with age and grouping (P laser with original flap cut parameter settings could increase the incidence of RG. The narrower grating size and lower pulse energy could ameliorate this side effect.

  4. A review of laser and light therapy in melasma

    Directory of Open Access Journals (Sweden)

    M.K. Trivedi, BS, BA

    2017-03-01

    Full Text Available Melasma is a dysregulation of the homeostatic mechanisms that control skin pigmentation and excess pigment is produced. Traditional treatment approaches with topical medications and chemical peels are commonly used but due to the refractory and recurrent nature of melasma, patients often seek alternative treatment strategies such as laser and light therapy. Several types of laser and light therapy have been studied in the treatment of melasma. Intense pulsed light, low fluence Q-switched lasers, and non-ablative fractionated lasers are the most common lasers and light treatments that are currently performed. They all appear effective but there is a high level of recurrence with time and some techniques are associated with an increased risk for postinflammatory hyper- or hypopigmentation. The number and frequency of treatments varies by device type but overall, Q-switched lasers require the greatest number of treatment applications to see a benefit. Vascular-specific lasers do not appear to be effective for the treatment of melasma. Ablative fractionated lasers should be used with caution because they have a very high risk for postinflammatory hypo- and hyperpigmentation. The use of nonablative fractionated laser treatments compared with other laser and light options may result in slightly longer remission intervals. Picosecond lasers, fractional radiofrequency, and laser-assisted drug delivery are promising future approaches to treat melasma. The goal of this review is to summarize the efficacy and safety of the most commonly used laser and light therapies to treat melasma, briefly present future laser-based treatment options for patients with melasma, and provide recommendations for treatment on the basis of the reviewed information.

  5. Nuclear-driven flashlamp pumping of the atomic iodine laser

    International Nuclear Information System (INIS)

    Miley, G.H.

    1992-03-01

    This report is a study of the atomic iodine laser pumped with nuclear- excited XeBr fluorescence. Preliminary experiments, conducted in the TRIGA reactor investigated the fluorescence of the excimer XeBr under nuclear pumping with 10 B and 3 He, for use as a flashlamp gas to stimulate the laser. These measurements included a determination of the fluorescence efficiency (light emitted in the wavelength region of interest, divided by energy deposited in the gas) of XeBr under nuclear pumping, with varying excimer mixtures. Maximum fluorescence efficiencies were approximately 1%. In order to better understand XeBr under nuclear excitation, a kinetics model of the system was prepared. The model generated the time-dependant concentrations of 20 reaction species for three pulse sizes, a TRIGA pulse, a fast burst reactor pulse, and an e-beam pulse. The modeling results predicted fluorescence efficiencies significantly higher (peak efficiencies of approximately 10%) than recorded in the fluorescence experiments. The cause of this discrepancy was not fully determined. A ray tracing computer model was also prepared to evaluate the efficiency with which nuclear-induced fluorescence generated in one cavity of a laser could be coupled into another cavity containing an iodine lasant. Finally, an experimental laser cell was constructed to verify that nuclear-induced XeBr fluorescence could be used to stimulate a laser. Lasing was achieved at 1.31 micron in the TRIGA using C 3 F 7 I, a common iodine lasant. Peak laser powers were approximately 20 mW. Measured flashlamp pump powers at threshold agreed well with literature values, as did lasant pressure dependency on laser operation

  6. Ultraviolet light imaging technology and applications

    Science.gov (United States)

    Yokoi, Takane; Suzuki, Kenji; Oba, Koichiro

    1991-06-01

    Demands on the high-quality imaging in ultraviolet (UV) light region have been increasing recently, especially in fields such as forensic investigations, laser experiments, spent fuel identification, and so on. Important requirements on the UV imaging devices in such applications are high sensitivity, excellent solar blindness, and small image distortion, since the imaging of very weak UV images are usually carried out under natural sunlight or room illuminations and the image data have to be processed to produce useful two-dimensional quantitative data. A new photocathode has been developed to meet these requirements. It is specially made of RbTe on a sapphire window and its quantum efficiency is as high as 20% with the solar blindness of 10,000. The tube is specially designed to meet UV light optics and to minimize image distortion. It has an invertor type image intensifier tube structure and intensifies the incident UV light up to approximately 10,000 times. The distortion of the output image is suppressed less than 1.8%, because of a specially designed electron optic lens system. The device has shown excellent results in the observation of such objects as fingerprints and footprints in forensic investigations, the Cherenkov light produced by the spent fuels stored in a cooling water pool in the nuclear power station, and UV laser beam path in excimer laser experiments. Furthermore, many other applications of the UV light imaging will be expected in various fields such as semiconductors, cosmetics, and electrical power.

  7. Transformation of medical grade silicone rubber under Nd:YAG and excimer laser irradiation: First step towards a new miniaturized nerve electrode fabrication process

    International Nuclear Information System (INIS)

    Dupas-Bruzek, C.; Robbe, O.; Addad, A.; Turrell, S.; Derozier, D.

    2009-01-01

    Medical grade silicone rubber, poly-dimethylsiloxane (PDMS) is a widely used biomaterial. Like for many polymers, its surface can be modified in order to change one or several of its properties which further allow this surface to be functionalized. Laser-induced surface modification of PDMS under ambient conditions is an easy and powerful method for the surface modification of PDMS without altering its bulk properties. In particular, we profit from both UV laser inducing surface modification and of UV laser micromachining to develop a first part of a new process aiming at increasing the number of contacts and tracks within the same electrode surface to improve the nerve selectivity of implantable self sizing spiral cuff electrodes. The second and last part of the process is to further immerse the engraved electrode in an autocatalytic Pt bath leading in a selective Pt metallization of the laser irradiated tracks and contacts and thus to a functionalized PDMS surface. In the present work, we describe the different physical and chemical transformations of a medical grade PDMS as a function of the UV laser and of the irradiation conditions used. We show that the ablation depths, chemical composition, structure and morphology vary with (i) the laser wavelength (using an excimer laser at 248 nm and a frequency-quadrupled Nd:YAG laser at 266 nm), (ii) the conditions of irradiation and (iii) the pulse duration. These different modified properties are expected to have a strong influence on the nucleation and growth rates of platinum which govern the adhesion and the thickness of the Pt layer on the electrodes and thus the DC resistance of tracks.

  8. Advances in solid state laser technology for space and medical applications

    Science.gov (United States)

    Byvik, C. E.; Buoncristiani, A. M.

    1988-01-01

    Recent developments in laser technology and their potential for medical applications are discussed. Gas discharge lasers, dye lasers, excimer lasers, Nd:YAG lasers, HF and DF lasers, and other commonly used lasers are briefly addressed. Emerging laser technology is examined, including diode-pumped lasers and other solid state lasers.

  9. Effect of excimer laser annealing on a-InGaZnO thin-film transistors passivated by solution-processed hybrid passivation layers

    Science.gov (United States)

    Bermundo, Juan Paolo; Ishikawa, Yasuaki; Fujii, Mami N.; Nonaka, Toshiaki; Ishihara, Ryoichi; Ikenoue, Hiroshi; Uraoka, Yukiharu

    2016-01-01

    We demonstrate the use of excimer laser annealing (ELA) as a low temperature annealing alternative to anneal amorphous InGaZnO (a-IGZO) thin-film transistors (TFTs) passivated by a solution-processed hybrid passivation layer. Usually, a-IGZO is annealed using thermal annealing at high temperatures of up to 400 °C. As an alternative to high temperature thermal annealing, two types of ELA, XeCl (308 nm) and KrF (248 nm) ELA, are introduced. Both ELA types enhanced the electrical characteristics of a-IGZO TFTs leading to a mobility improvement of ~13 cm2 V-1 s-1 and small threshold voltage which varied from ~0-3 V. Furthermore, two-dimensional heat simulation using COMSOL Multiphysics was used to identify possible degradation sites, analyse laser heat localization, and confirm that the substrate temperature is below 50 °C. The two-dimensional heat simulation showed that the substrate temperature remained at very low temperatures, less than 30 °C, during ELA. This implies that any flexible material can be used as the substrate. These results demonstrate the large potential of ELA as a low temperature annealing alternative for already-passivated a-IGZO TFTs.

  10. Laser light scattering instrument advanced technology development

    Science.gov (United States)

    Wallace, J. F.

    1993-01-01

    The objective of this advanced technology development (ATD) project has been to provide sturdy, miniaturized laser light scattering (LLS) instrumentation for use in microgravity experiments. To do this, we assessed user requirements, explored the capabilities of existing and prospective laser light scattering hardware, and both coordinated and participated in the hardware and software advances needed for a flight hardware instrument. We have successfully breadboarded and evaluated an engineering version of a single-angle glove-box instrument which uses solid state detectors and lasers, along with fiber optics, for beam delivery and detection. Additionally, we have provided the specifications and written verification procedures necessary for procuring a miniature multi-angle LLS instrument which will be used by the flight hardware project which resulted from this work and from this project's interaction with the laser light scattering community.

  11. Laser induced white lighting of tungsten filament

    Science.gov (United States)

    Strek, W.; Tomala, R.; Lukaszewicz, M.

    2018-04-01

    The sustained bright white light emission of thin tungsten filament was induced under irradiation with focused beam of CW infrared laser diode. The broadband emission centered at 600 nm has demonstrated the threshold behavior on excitation power. Its intensity increased non-linearly with excitation power. The emission occurred only from the spot of focused beam of excitation laser diode. The white lighting was accompanied by efficient photocurrent flow and photoelectron emission which both increased non-linearly with laser irradiation power.

  12. Laser warning receiver to identify the wavelength and angle of arrival of incident laser light

    Science.gov (United States)

    Sinclair; Michael B.; Sweatt, William C.

    2010-03-23

    A laser warning receiver is disclosed which has up to hundreds of individual optical channels each optically oriented to receive laser light from a different angle of arrival. Each optical channel has an optical wedge to define the angle of arrival, and a lens to focus the laser light onto a multi-wavelength photodetector for that channel. Each multi-wavelength photodetector has a number of semiconductor layers which are located in a multi-dielectric stack that concentrates the laser light into one of the semiconductor layers according to wavelength. An electrical signal from the multi-wavelength photodetector can be processed to determine both the angle of arrival and the wavelength of the laser light.

  13. Slow-light effects in photonic crystal membrane lasers

    DEFF Research Database (Denmark)

    Xue, Weiqi; Yu, Yi; Ottaviano, Luisa

    2015-01-01

    In this paper, we present a systematic investigation of photonic crystal cavity laser operating in the slow-light regime. The dependence of lasing threshold on the effect of slow-light will be particularly highlighted.......In this paper, we present a systematic investigation of photonic crystal cavity laser operating in the slow-light regime. The dependence of lasing threshold on the effect of slow-light will be particularly highlighted....

  14. Mass-Selective Laser Photoionization.

    Science.gov (United States)

    Smalley, R. E.

    1982-01-01

    Discusses the nature and applications of mass-selective laser photoionization. The ionization can be done with a single intense laser pulse lasting a few billionths of a second with no molecular fragmentation. Applications focus on: (1) benzene clusters, excimers, and exciplexes; (2) metal clusters; and (3) triplet formation and decay. (Author/JN)

  15. Instantaneous three-dimensional visualization of concentration distributions in turbulent flows with crossed-plane laser-induced fluorescence imaging

    Science.gov (United States)

    Hoffmann, A.; Zimmermann, F.; Scharr, H.; Krömker, S.; Schulz, C.

    2005-01-01

    A laser-based technique for measuring instantaneous three-dimensional species concentration distributions in turbulent flows is presented. The laser beam from a single laser is formed into two crossed light sheets that illuminate the area of interest. The laser-induced fluorescence (LIF) signal emitted from excited species within both planes is detected with a single camera via a mirror arrangement. Image processing enables the reconstruction of the three-dimensional data set in close proximity to the cutting line of the two light sheets. Three-dimensional intensity gradients are computed and compared to the two-dimensional projections obtained from the two directly observed planes. Volume visualization by digital image processing gives unique insight into the three-dimensional structures within the turbulent processes. We apply this technique to measurements of toluene-LIF in a turbulent, non-reactive mixing process of toluene and air and to hydroxyl (OH) LIF in a turbulent methane-air flame upon excitation at 248 nm with a tunable KrF excimer laser.

  16. Necessary conditions for the homogeneous formation of a volume avalanche discharge with specific applications to rare gas-halide excimer laser discharges

    International Nuclear Information System (INIS)

    Levatter, J.I.

    1979-01-01

    Self-sustained/avalanche discharges are an efficient method of rare gas-halide excimer laser excitation in small systems. However, with the exceptions of the work reported here, experiments attempting to increase the laser energy output by scaling up the discharge volume and/or pulse duration have not been successful. The major problem encountered in scaling experiments has been the formation of arc channels in the discharge volume. The presence of arcing can totally disrupt proper laser operation. This problem stems from a general lack of understanding of high pressure avalanche discharge phenomena. Therefore, clarifying the basic discharge formation process and establishing a set of criteria under which a homogeneous avalanche discharge can be obtained is of central importance in defining the scaling limits of avalanche discharge lasers. The work presented here reviews the phenomena involved in high E/n (electric field to gas number density ratio) breakdown and its relationship to the formation of spatially homogeneous discharges. This relationship was first explored by A.J. Palmer in 1974. The basic requirement of his model was that the preionization density be large enough to cause an appreciable overlap of the primary electron avalanches and hence smooth out the ensuing space-charge fields to the extent that individual streamer formation would be prevented. This is the same basic model used in the more detailed discharge formation analysis developed here except that the effects of a time varying electric field caused by a finite voltage rise time and the effects due to the various electrochemical properties of the gas mixture are property taken into consideration

  17. Laser annealed HWCVD and PECVD thin silicon films. Electron field emission

    International Nuclear Information System (INIS)

    O'Neill, K.A.; Shaikh, M.Z.; Lyttle, G.; Anthony, S.; Fan, Y.C.; Persheyev, S.K.; Rose, M.J.

    2006-01-01

    Electron Field Emission (FE) properties of various laser annealed thin silicon films on different substrates were investigated. HWCVD microcrystalline and PECVD amorphous silicon films were irradiated with Nd : YAG and XeCl Excimer lasers at varying energy densities. Encouraging FE results were mainly from XeCl Excimer laser processed PECVD and HWCVD films on metal backplanes. FE measurements were complemented by the study of film surface morphology. Geometric field enhancement factors from surface measurements and Fowler-Nordheim Theory (FNT) were compared. FE properties of the films were also found to be particularly influenced by the backplane material

  18. Separation of nitrogen isotopes by laser light

    Energy Technology Data Exchange (ETDEWEB)

    Izawa, Y; Noguchi, Y; Yamanaka, C [Osaka Univ., Suita (Japan). Faculty of Engineering

    1976-06-01

    The separation experiment on nitrogen isotopes by laser light was made. First, the nitrogen isotopes of /sup 14/N and /sup 15/N in NH/sub 3/ molecules were separated by CO/sub 2/ laser and UV light. The separation factor and the enrichment factor were calculated. It was shown that their pressure dependence was in good agreement with the measured values. The separation factor of about 2% was obtained with UV light of 10/sup 6/W/cm/sup 2/.

  19. Decontamination by excimer laser

    International Nuclear Information System (INIS)

    2001-01-01

    The process developed in collaboration with the C.N.R.S. has reached the industrial stage. The transport by optical fibre beam has been perfected and allows to work from a distance of 20 m from the source. Demonstration has been made with a laser of a 500 watt power which allows a 5 to 10 m 2 /hour etching efficiency. This process is in the course of qualification in collaboration with the different organisations: C.E.A., COGEMA and E.D.F. This qualification concerns 25 different materials and zircaloy fuel claddings. (author)

  20. Effect of UV laser irradiation on tissue

    International Nuclear Information System (INIS)

    Nakayama, Takeyoshi; Kubo, Uichi

    1992-01-01

    Laser-tissue interactions have been investigated through Electron Probe Micro Analysis (EPMA), UV-visible optical absorption and Fourier Transform Infrared Spectroscopy (FTIR). Three excimer lasers, ArF, KrF and XeCl, were used to irradiate tissue; cow thighbone and gelatin thin film. Features of UV laser irradiation are described. (author)

  1. Light/laser therapy in the treatment of acne vulgaris.

    Science.gov (United States)

    Nouri, Keyvan; Villafradez-Diaz, L Magaly

    2005-12-01

    Acne vulgaris is one of the most prevalent skin diseases known. As common as this condition is, the social and psychological consequences are limitless. Although current treatments are available and include topical or oral antibiotics, it is crucial to develop a less risky and more effective therapy such as light/laser therapy. This article focuses specifically on the benefits of the light/laser treatment on acne vulgaris. Porphyrins accumulated in the bacteria, Propionibacterium acnes, one of the etiologic factors involved in the pathogenesis, allows phototherapy to be a successful modality. They have specific absorption peaks at which lasers have optimal effects. The longer the wavelength of the light is, the deeper its penetration and thus the greater its damage to the sebaceous glands. Although blue light is best for the activation of porphyrins, red light is best for deeper penetration and an anti-inflammatory effect. Ultraviolet (UV) light, although it may have initial an anti-inflammatory effects, has been proven to be potentially carcinogenic and have adverse effects such as aging (by UV-A) and burning (by UV-B). Previous studies indicate successful long-term intervention and selective damage of the sebaceous glands by using a diode laser with indocyanine green (ICG) dye. Mid-infrared lasers have been found to decrease lesion counts while also reducing the oiliness of skin and the scarring process. Nonablative laser treatment of acne scars using the Er:YAG laser with a short-pulsed mode has been successful in reducing the appearance of scars by stimulating neocollagenesis. The light/laser therapy has started to be explored with promising results in highly selected patients that require further investigation in greater populations and well-designed protocols.

  2. Pulsed UV laser technologies for ophthalmic surgery

    International Nuclear Information System (INIS)

    Razhev, A M; Bagayev, S N; Churkin, D S; Kargapol’tsev, E S; Chernykh, V V; Iskakov, I A; Ermakova, O V

    2017-01-01

    The paper provides an overview of the results of multiyear joint researches of team of collaborators of Institute of Laser Physics SB RAS together with NF IRTC “Eye Microsurgery” for the period from 1988 to the present, in which were first proposed and experimentally realized laser medical technologies for correction of refractive errors of known today as LASIK, the treatment of ophthalmic herpes and open-angle glaucoma. It is proposed to carry out operations for the correction of refractive errors the use of UV excimer KrCl laser with a wavelength of 222 nm. The same laser emission is the most suitable for the treatment of ophthalmic herpes, because it has a high clinical effect, combined with many years of absence of recrudescence. A minimally invasive technique of glaucoma operations using excimer XeCl laser (λ=308 nm) is developed. Its wavelength allows perform all stages of glaucoma operations, while the laser head itself has high stability and lifetime, will significantly reduce operating costs, compared with other types of lasers. (paper)

  3. FY 1997 report on the study on cryogenic aggregate target PLD process by multi-laser excitation for using gaseous materials; 1997 nendo chosa hokokusho (kitai genryo riyo no tame no taju laser reiki ni yoru gokuteion gyoshutai target PLD process ni kansuru kenkyu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    This paper reports the result in fiscal 1995 of the study on PLD (pulse laser deposition) thin film formation process having been made since 1993. In fiscal 1995, the effect of irradiation of excimer laser and YGA(SHG) on ablation of aggregates of N2, CH4, Ar, Kr and Xe, and the effect of time-delayed irradiation of YGA(SHG) and KrF excimer laser on ablation of N2 aggregate were studied aiming at exciting ablation by cryogenic aggregate alone. Experimental results by a newly developed multi-laser excitation experiment equipment are as follows. Ablation was not caused by KrF excimer laser irradiation, while caused by YGA(SHG) irradiation. Ablation was caused by 1mm thick N2 or CH4 aggregate alone. Kr target was the most promising among rare gas solid targets expected as seed of ablation occurrence. Multi-irradiation showed a different ablation behavior as compared with single YGA(SHG) irradiation, and in some cases, multi-irradiation not increased scattering of particles. Time-delayed multi- irradiation (YGA(SHG) excitation after excimer excitation) was effective. 23 figs., 4 tabs.

  4. Laser light scattering basic principles and practice

    CERN Document Server

    Chu, Benjamin

    1994-01-01

    Geared toward upper-level undergraduate and graduate students, this text introduces the interdisciplinary area of laser light scattering, focusing chiefly on theoretical concepts of quasielastic laser scattering.

  5. LASEK for the correction of hyperopia with mitomycin C using SCHWIND AMARIS excimer laser: one-year follow-up

    Directory of Open Access Journals (Sweden)

    Khosrow Jadidi

    2015-11-01

    Full Text Available AIM: To evaluate the efficacy, safety and predictability of laser-assisted sub-epithelial keratectomy(LASEKfor the correction of hyperopia using the SCHWIND AMARIS platform.METHODS: This retrospective single-surgeon study includes 66 eyes of 33 patients with hyperopia who underwent LASEK with mitomycin C(MMC. The median age of patients was 35.42±1.12y(ranging 18 to 56y. In each patient LASEK was performed using SCHWIND AMARIS excimer laser. Postoperatively clinical outcomes were evaluated in terms of predictability, safety, efficacy, subjective and objective refractions, uncorrected visual acuity(UCVA, best spectacle-corrected visual acuity(BSCVAand adverse events. RESULTS: The mean baseline refraction was 3.2±1.6 diopters(D(ranging 0 to 7 D. The mean pre-operative and postoperative spherical equivalent(SEwere 2.34±1.76(ranging -1.25 to 7 Dand 0.30±0.84(ranging -0.2 to 0.8 Drespectively(P=0.001. The mean hyperopia was 0.63±0.84 D(ranging -1.75 to 2.76 D6 to 12mo postoperatively. Likewise, the mean astigmatism was 0.68±0.43 D(range 0 to 2 Dwith 51(77.3%and 15(22.7%eyes within ±1 and ±0.50 D respectively. The safety index and efficacy index were 1.08 and 1.6 respectively.CONCLUSION:LASEK using SCHWIND AMARIS with MMC yields good visual and refractive results for hyperopia. Moreover, there were no serious complications.

  6. Lasers '90: Proceedings of the 13th International Conference on Lasers and Applications, San Diego, CA, Dec. 10-14, 1990

    International Nuclear Information System (INIS)

    Harris, D.G.; Herbelin, J.

    1991-01-01

    The general topics considered are: x-ray lasers; FELs; solid state lasers; techniques and phenomena of ultrafast lasers; optical filters and free space laser communications; discharge lasers; tunable lasers; applications of lasers in medicine and surgery; lasers in materials processing; high power lasers; dynamics gratings, wave mixing, and holography; up-conversion lasers; lidar and laser radar; laser resonators; excimer lasers; laser propagation; nonlinear and quantum optics; blue-green technology; imaging; laser spectroscopy; chemical lasers; dye lasers; and lasers in chemistry

  7. Keratin film ablation for the fabrication of brick and mortar skin structure using femtosecond laser pulses

    Science.gov (United States)

    Haq, Bibi Safia; Khan, Hidayat Ullah; Dou, Yuehua; Alam, Khan; Attaullah, Shehnaz; Zari, Islam

    2015-09-01

    The patterning of thin keratin films has been explored to manufacture model skin surfaces based on the "bricks and mortar" view of the relationship between keratin and lipids. It has been demonstrated that laser light is capable of preparing keratin-based "bricks and mortar" wall structure as in epidermis, the outermost layer of the human skin. "Bricks and mortar" pattern in keratin films has been fabricated using an ArF excimer laser (193 nm wavelength) and femtosecond laser (800 and 400 nm wavelength). Due to the very low ablation threshold of keratin, femtosecond laser systems are practical for laser processing of proteins. These model skin structures are fabricated for the first time that will help to produce potentially effective moisturizing products for the protection of skin from dryness, diseases and wrinkles.

  8. Low temperature high-mobility InZnO thin-film transistors fabricated by excimer laser annealing

    NARCIS (Netherlands)

    Fujii, M.; Ishikawa, Y.; Ishihara, R.; Van der Cingel, J.; Mofrad, M.R.T.; Horita, M.; Uraoka, Y.

    2013-01-01

    In this study, we successfully achieved a relatively high field-effect mobility of 37.7?cm2/Vs in an InZnO thin-film transistor (TFT) fabricated by excimer layer annealing (ELA). The ELA process allowed us to fabricate such a high-performance InZnO TFT at the substrate temperature less than 50?°C

  9. Effect of laser-diode light on growth of Lactuca sativa L

    International Nuclear Information System (INIS)

    Yamazaki, A.; Tsuchiya, H.; Miyajima, H.; Honma, T.; Kan, H.

    2000-01-01

    Development of an effective, high-power, low-cost, artificial light source for use in plant-growing facilities would be very beneficial for plant production. Recently, the laser-diode lamp was proposed as a new type of light source for plant production. The advantages of the laser-diode lamp over conventional light sources are its high electrical-to-optical power conversion efficiency, low thermal radiation, easy set-up for high power and pulse irradiation, small weight and small volume for mounting, and selectivity for proper wavelength. Because laser light itself differs from the light sources presently used in plant growing, we confirmed the possibility of growing plants under the laser-diode light using lettuces. Lettuce seedlings with 5-6 leaves were grown under a laser-diode lamp panel with 30 pieces of high-power and high-efficiency AlGaInP laser-diodes. The power of each laser-diode lamp was 500 mW, and the wavelength was 680 nm, which was efficient for photosynthesis. The lettuce plants were able to grow under the laser-diode light. However, plants were lighter and had thinner leaves than those grown under high-pressure sodium lamps. (author)

  10. Excimer laser phototherapeutic keratectomy in conjunction with mitomycin C in corneal macular and granular dystrophies.

    Science.gov (United States)

    Yuksel, Erdem; Cubuk, Mehmet Ozgur; Eroglu, Hulya Yazıcı; Bilgihan, Kamil

    2016-04-01

    To evaluate the visual outcomes, recurrence patterns, safety, and efficacy of excimer laser phototherapeutic keratectomy (PTK) in conjunction with mitomycin C (MMC) for corneal macular and granular diystrophies. The patients were divided into two groups. Group 1 included patients with macular corneal dystrophy (MCD) that caused superficial corneal plaque opacities, and Group 2 included patients with granular corneal dystrophy (GCD). Patients in both groups were pre-, peri-, and postoperatively evaluated. The groups were compared in terms of uncorrected visual acuity (VA), best spectacle-corrected VA, presence of mild or significant recurrence, and time of recurrence. Eighteen eyes (nine with MCD and nine with GCD) of 18 patients (10 men and eight women) were included. PTK was performed for each eye that was included in this study. The mean ablation amount was 117.8 ± 24.4 µm and 83.5 ± 45.7 µm in MCD and GCD, respectively, (p=0.18). The postoperative improvement of the mean VA was similar between the two groups before recurrences (p>0.43) and after recurrences (p>0.71). There were no statistically significant differences in the recurrence rate and the recurrence-free period for any recurrence type. PTK was an effective, safe, and minimally invasive procedure for patients with MCD and GCD. PTK in conjunction with MMC was similarly effective for both groups in terms of recurrence and visual outcomes.

  11. Phenylethynylpyrene excimer forming hybridization probes for fluorescence SNP detection

    DEFF Research Database (Denmark)

    Prokhorenko, Igor A.; Astakhova, Irina V.; Momynaliev, Kuvat T.

    2009-01-01

    Excimer formation is a unique feature of some fluorescent dyes (e.g., pyrene) which can be used for probing the proximity of biomolecules. Pyrene excimer fluorescence has previously been used for homogeneous detection of single nucleotide polymorphism (SNP) on DNA. 1-Phenylethynylpyrene (1-1-PEPy...

  12. Magnetic field generation by circularly polarized laser light and inertial plasma confinement in a miniature 'Magnetic Bottle' induced by circularly polarized laser light

    International Nuclear Information System (INIS)

    Kolka, E.

    1993-07-01

    A new concept of hot plasma confinement in a miniature magnetic bottle induced by circularly polarized laser light is suggested in this work. Magnetic fields generated by circularly polarized laser light may be of the order of megagauss. In this configuration the circularly polarized laser light is used to get confinement of a plasma contained in a good conductor vessel. The poloidal magnetic field induced by the circularly polarized laser and the efficiency of laser absorption by the plasma are calculated in this work. The confinement in this scheme is supported by the magnetic forces and the Lawson criterion for a DT plasma might be achieved for number density n=5*10 21 cm -3 and confinement time τ= 20 nsec. The laser and the plasma parameters required to get an energetic gain are calculated. (authors)

  13. Effect of excimer laser annealing on a-InGaZnO thin-film transistors passivated by solution-processed hybrid passivation layers

    International Nuclear Information System (INIS)

    Bermundo, Juan Paolo; Ishikawa, Yasuaki; Fujii, Mami N; Uraoka, Yukiharu; Nonaka, Toshiaki; Ishihara, Ryoichi; Ikenoue, Hiroshi

    2016-01-01

    We demonstrate the use of excimer laser annealing (ELA) as a low temperature annealing alternative to anneal amorphous InGaZnO (a-IGZO) thin-film transistors (TFTs) passivated by a solution-processed hybrid passivation layer. Usually, a-IGZO is annealed using thermal annealing at high temperatures of up to 400 °C. As an alternative to high temperature thermal annealing, two types of ELA, XeCl (308 nm) and KrF (248 nm) ELA, are introduced. Both ELA types enhanced the electrical characteristics of a-IGZO TFTs leading to a mobility improvement of ∼13 cm 2 V −1 s −1 and small threshold voltage which varied from ∼0–3 V. Furthermore, two-dimensional heat simulation using COMSOL Multiphysics was used to identify possible degradation sites, analyse laser heat localization, and confirm that the substrate temperature is below 50 °C. The two-dimensional heat simulation showed that the substrate temperature remained at very low temperatures, less than 30 °C, during ELA. This implies that any flexible material can be used as the substrate. These results demonstrate the large potential of ELA as a low temperature annealing alternative for already-passivated a-IGZO TFTs. (paper)

  14. Lasers, light-atom interaction

    International Nuclear Information System (INIS)

    Cagnac, B.; Faroux, J.P.

    2002-01-01

    This book has a double purpose: first to explain in a way as simple as possible the interaction processes occurring between atoms and light waves, and secondly to help any scientist that needs further information to improve his knowledge of lasers. The content of this book has been parted into 3 more or less independent sections: 1) effect of an electromagnetic field on a 2-quantum state system, 2) operating mode of lasers in the framework of transition probabilities, and 3) calculation of the emitted wave. Einstein's phenomenological hypothesis has led to probability equations called rate equations, these equations do not give a true representation of the interaction process at the scale of the atom but this representation appears to be true on an average over a large population of atoms. Only quantum mechanics can describe accurately the light-atom interaction but at the cost of a far higher complexity. In the first part of the book quantum mechanics is introduced and applied under 2 simplifying hypothesis: -) the atom system has only 2 non-degenerate states and -) the intensity of the light wave is high enough to involve a large population of photons. Under these hypothesis, Rabi oscillations, Ramsey pattern and the splitting of Autler-Townes levels are explained. The second part is dedicated to the phenomenological model of Einstein that gives good results collectively. In the third part of the book, Maxwell equations are used to compute field spatial distribution that are currently found in experiments involving lasers. (A.C.)

  15. LIGHT: Towards a laser-based accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Busold, Simon; Deppert, Oliver; Roth, Markus [Technical University of Darmstadt, Institute for Nuclear Physics, Schlossgartenstrasse 9, 64289 Darmstadt (Germany); Brabetz, Christian [Goethe University Frankfurt am Main, Institute for Applied Physics, Max von Laue Strasse 1, 60438 Frankfurt (Germany); Burris-Mog, Trevor; Joost, Martin; Cowan, Tom [Helmholtz Center Dresden-Rossendorf, Bautzner Landstrasse 400, 01328 Dresden (Germany); Blazevic, Abel; Bagnoud, Vincent [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Zielbauer, Bernhard [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Helmholtz Institute Jena, Helmholtzweg 4, 07743 Jena (Germany); Kester, Oliver [GSI Helmholtz Center for Heavy Ion Research, Planckstrasse 1, 64291 Darmstadt (Germany); Goethe University Frankfurt am Main, Institute for Applied Physics, Max von Laue Strasse 1, 60438 Frankfurt (Germany)

    2012-07-01

    Proton acceleration by ultrashort, high intensity laser pulses has been a fast growing field of research during the last decade. The most intensely investigated acceleration mechanism is the TNSA mechanism (Target Normal Sheath Acceleration), providing protons in the multi-MeV-range. For many possible applications, however, the full energy spread and large beam divergence are major draw-backs. Therefore, a pulsed high-field solenoid was used for collimation and energy-selection and is now integrated in a full test stand for a laser-based accelerator at GSI Helmholtz Center, Darmstadt, namely the LIGHT project (Laser Ion Generation, Handling and Transport), which is a collaboration between TU Darmstadt, GSI, HZDR, JWGU Frankfurt and HI Jena. An overview of the new infrastructure, the goals of the LIGHT project, and first experimental results are presented.

  16. Visible Lasers and Emerging Color Converters for Lighting and Visible Light Communications

    KAUST Repository

    Shen, Chao

    2017-10-30

    GaN-based lasers are promising for white lighting and visible-light communication (VLC). The advances of III-nitride photonic integration, and the application of YAG crystal and perovskite-based phosphors to lighting and VLC will be discussed.

  17. Visible Lasers and Emerging Color Converters for Lighting and Visible Light Communications

    KAUST Repository

    Shen, Chao

    2017-01-01

    GaN-based lasers are promising for white lighting and visible-light communication (VLC). The advances of III-nitride photonic integration, and the application of YAG crystal and perovskite-based phosphors to lighting and VLC will be discussed.

  18. [Reduction of decentration after LASIK using a modified eye tracker ring for the MEL-70 excimer laser].

    Science.gov (United States)

    Schulze, S; Nietgen, G; Sekundo, W

    2004-07-01

    The aim of this study was to determine and compare the rate of eccentric laser ablation after LASIK depending on the eye tracker ring used. All LASIK treatments were carried out using the MEL-70 flying spot excimer laser (Zeiss-Meditec, Jena). The flap was produced using a Corneal Shaper trade mark or Hansatome trade mark Microkeratome (B and L Surgical, Heidelberg). Initially we used an 11 mm eye tracker ring without hinge protector. At the end of February 2001 this ring was replaced by a 10 mm and a 9.5 mm ring with built-in hinge protector. An additional modification was introduced by us: at 1 mm separations little teeth-like spikes were engraved into the eyeward side of the ring, thus stabilising the position of the ring on the globe and allowing free liquid to flow through the spaces between each spike. The built-in calibration system of the corneal topography (TMS 3, Tomey, Erlangen) from patients with a follow-up of one month or longer was used to determine the distance between the centre of the ablation zone from the fixation point. In group I patients (old ring) 42 eyes were treated. In 4 eyes ablation was perfect, in 21 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 11 eyes 0.51 to 0.99 mm and in 5 eyes 1.1 to 1.49 mm whereas one eye showed a decentred ablation of 1.53 mm. In group II (new ring) 42 eyes were investigated also. In 11 eyes ablation was perfect, in 20 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 10 eyes 0.5 to 0.99 mm and one eye had an eccentric ablation of 1.28 mm from the fixation point. The further development of our eye tracker ring for the MEL-70 laser considerably reduced the rate of decentred ablations. An enhanced grip of the ring onto the globe reduces a slow slide during the laser procedure.

  19. [Light, laser and PDT therapy for acne].

    Science.gov (United States)

    Borelli, C; Merk, K; Plewig, G; Degitz, K

    2005-11-01

    In recent years, a number of studies have evaluated the treatment of acne using electromagnetic waves, such as lasers, photodynamic therapy, visible light or radio waves. While the efficacy of laser treatment is still uncertain, photodynamic therapy shows promising results, but with marked side-effects, as destruction of sebaceous glands. Treatment with blue light (405-420 nm wavelength) also appears effective and can be regarded as an treatment option for inflammatory acne.

  20. Identification of photoacoustic transients during pulsed laser ablation of the human temporal bone: an experimental model.

    Science.gov (United States)

    Wong, B J; Dickinson, M R; Berns, M W; Neev, J

    1996-12-01

    Laser ablation of hard tissues during neurotologic operations has been accomplished with continuous-wave (CW) lasers in the visible and midinfrared spectrum. The mechanism of ablation at these wavelengths is secondary to photothermal-induced tissue destruction. As a result, significant thermal damage to surrounding tissue may occur. Pulsed ultraviolet (UV) lasers have been suggested as an alternative to the argon, KTP-532, and CO2 lasers currently used in clinical practice. The pulse length of Excimer lasers are considerably shorter than the thermal diffusion time of bone tissue, and as a consequence thermal injury is minimal. This makes pulsed lasers an attractive tool for tissue ablation in the ear: in essence a "cold knife." However, the short pulse width of Excimer lasers (typically 10-150 ns) can create large thermoelastic stresses in the ablation specimen. This study identifies the presence of these photoacoustic waves during the Excimer laser treatment of the cadaveric human temporal bone. A XeCl (lambda = 308 nm, tau p = 12 ns) excimer laser was used to ablate hard tissue surrounding the oval window and facial ridge with energies of 75, 45, 25, and 12 mJ/pulse. Spot size was estimated to be 0.5 mm2. Custom high-frequency polyvinyldifluoride (PVDF) piezoelectric film transducers were fabricated and attached to the promontory, round window niche, and facial ridges. The signals were amplified using a low-noise preamplifier and recorded on a digitizing oscilloscope. Photoacoustic waves were clearly identified. Notably, large acoustic waves were measured on the promontory and on both sides of the facial ridge. The implications and clinical relevance of these findings is discussed and compared to findings obtained from a model system.

  1. Optimization of laser scribing for thin-film PV modules. Final technical progress report, 12 April 1995--11 October 1997

    Energy Technology Data Exchange (ETDEWEB)

    Compaan, A.D.; Matulionis, I.; Nakade, S. [Univ. of Toledo, OH (United States)

    1998-06-01

    This report covers the work done by the University of Toledo under this subcontract. Researchers determined the threshold power densities for the onset of ablation from thin films of CdTe, CuInSe{sub 2}, SnO{sub 2}:F, ZnO:Al, gold, and molybdenum for 12 different wavelength laser systems using wide variations of laser pulse durations. Optimum energy density for the most efficient removal of material during scribing strongly depends on the wavelength of the laser and, to a smaller extent, on the pulse duration. The optimum energy densities range from 0.5 J/sq cm for the 532-nm, 8-nsec YAG pulse on CdTe to 0.2 J/sq cm for the excimer laser at 308 nm on CIS. Poor scribing of CdTe was seen with the 1064-nm beam, ZnO was scribed poorly by all lasers except for the excimer laser. Excellent scribe profiles were observed with the 308-nm excimer lasers on all materials including ZnO.

  2. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia.

    Science.gov (United States)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob; Grønbech, Keea Treu; Vestergaard, Anders Højslet

    2015-07-01

    We aimed to evaluate and compare outcomes after photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. This was a retrospective, single-masked follow-up study of patients treated for myopia between 2007 and 2009 with cPRK or LASEK, using a high-frequency flying-spot excimer laser with eye-tracker (MEL80; Carl Zeiss, Jena, Germany). One eye of each patient was randomly chosen for analysis. Re-treated eyes were excluded. Forty-six cPRK patients and 35 LASEK patients were included. Spherical equivalent averaged -7.69 ± 1.47 diopters (D) in cPRK eyes and -7.98 ± 2.06 D in LASEK eyes (p = 0.31) before surgery. The average follow-up time was 4.6 years in cPRK patients and 6.0 years in LASEK patients (p < 0.05). At final follow-up, no cPRK eyes and one LASEK eye (p = 0.46) had lost two lines of corrected distance visual acuity (CDVA). No eyes had significant haze at final follow-up, although trace haze was found in four cPRK eyes and six LASEK eyes (p = 0.44). However, at 6 weeks after surgery, zero cPRK eyes and nine LASEK eyes (p < 0.05) had significant haze. At final follow-up, 63 % of cPRK eyes and 35 % of LASEK eyes (p = 0.17) were within ±1.0 D of intended refraction. Finally, 100 % of cPRK patients and 92 % of LASEK patients (p = 0.87) were satisfied or very satisfied with the surgery at final follow-up. cPRK and LASEK seemed safe and with high patient satisfaction 4 to 7 years after surgery for high myopia. However, cPRK was more effective than LASEK in reducing initial significant corneal haze.

  3. Self-phase modulation of laser light in laser produced plasma

    International Nuclear Information System (INIS)

    Yamanaka, C.; Yamanaka, T.; Mizui, J.; Yamaguchi, N.

    1975-02-01

    A spectrum broadening due to the self-phase modulation of a laser light was observed in the laser produced deuterium and hydrogen plasma. Qualitative treatments of the density modulation due to the self-focusing process and the modulational instability were discussed. The theoretical estimation of spectrum broadening fairly accorded with the experimental results. (auth.)

  4. Optical laser systems at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Minitti, Michael P.; Robinson, Joseph S.; Coffee, Ryan N.; Edstrom, Steve; Gilevich, Sasha; Glownia, James M.; Granados, Eduardo; Hering, Philippe; Hoffmann, Matthias C.; Miahnahri, Alan; Milathianaki, Despina; Polzin, Wayne; Ratner, Daniel; Tavella, Franz; Vetter, Sharon; Welch, Marc; White, William E.; Fry, Alan R., E-mail: alanfry@slac.stanford.edu [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-22

    This manuscript serves as a reference to describe the optical laser sources and capabilities at the Linac Coherent Light Source. Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump–probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump–probe experiments to be performed at LCLS.

  5. Effect of basic fibroblast growth factor and cytochrome c peroxidase combination in transgenic mice corneal epithelial healing process after excimer laser photoablation

    Directory of Open Access Journals (Sweden)

    Sergio Zaccaria Scalinci

    2011-02-01

    Full Text Available Sergio Zaccaria Scalinci1, Lucia Scorolli1, Alessandro Meduri2, Pier Luigi Grenga3, Giulia Corradetti1, Cristian Metrangolo11Low Vision Center – University of Bologna, Bologna, Italy; 2Department of Surgical Specialities, Ophthalmology Clinic, University of Messina, Messina, Italy; 3Department of Ophthalmology, University of Rome "La Sapienza", Rome, ItalyPurpose: To evaluate the role of prepared basic fibroblast growth factor (bFGF and cytochrome c peroxidase (CCP combination eyedrops in corneal epithelial healing of transgenic mice (B6(A-Rperd12/J after excimer laser photoablation. Materials and methods: In this prospective study, 216 eyes of 108 mice underwent bilateral photorefractive keratectomy. We considered 4 groups: A, B, C, and D. Group A received standard topical postoperative therapy with tobramycin, diclofenac, and dexamethasone eyedrops plus CCP at 3 drops per day for a week or until corneal re-epithelialization was achieved. Group B received standard topical postoperative therapy plus bFGF eyedrops and phosphate-buffered saline (PBS 3 drops per day for a week or until corneal re-epithelialization was complete. In group C, 1 eye received standard topical postoperative therapy plus CCP eyedrops, bFGF eyedrops, and PBS 3 drops per day for a week or until corneal re-epithelialization was complete. Control eyes (group D received a standard topical postoperative therapy plus placebo eyedrops. Mice were followed-up for a week from the day after the surgery to evaluate the rate of corneal re-epithelialization.Results: Data were analyzed by ANOVA using the XLSTAT 2010 software. Eyes in group A, B, and C healed completely before the fifth postoperative day, achieving, respectively, a re-epithelialization time of 92 hours ± 10 SD, 90 hours ± 12 SD, and 86 hours ± 12 SD. Group D had a re-epithelialization time of 121 hours ± 8 SD (P < 0.05. No side effects or toxic effects were documented.Conclusions: Results suggest that re

  6. Light-material interactions in laser material processing

    International Nuclear Information System (INIS)

    Chiang, S.; Albright, C.E.

    1989-01-01

    The authors discusses how light interactions with materials in laser material processing operations occur by a variety of mechanisms depending on the material being processed, the wavelength of the laser light, the gaseous environment, and the physical state of the material surface. The high reflectivity of metals limits the fraction of the beam power absorbed by the solid metal surface. For metals in the solid state, reflectivity increases as the wavelength of the laser light and the electrical conductivity of the metal increase. The reflectivity of metals is reduced upon heating to the melting point, and further reduced upon melting. At high power densities the liquid metal surface is heated so quickly that very rapid vaporization occurs. The recoil force produced by the evaporation causes a depression in the liquid/vapor interface. The keyhole resulting from this depression allows for multiple reflections and thus increases beam absorption in the liquid

  7. Laser driven white light source for BRDF measurement

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    In this paper, we will present a setup with laser driven light source (LDLS) for measuring a 2D bidirectional reflectance distribution function (BRDF). We have carried out measurements to acquire the BRDF of different samples based on our setup: which consists of a new laser driven broadband light...... source (UV-VIS-NIR), spectroradiometer and sample holder stepper motor in a dark UV-protected environment. Here, we introduced a special kind of light source which has a bright, stable, broad spectral range and well collimated light output to give a very good angular resolution. The experimental results...

  8. Tritium decontamination from co-deposited layer on tungsten substrate by ultra violet lamp and laser

    International Nuclear Information System (INIS)

    Oya, Yasuhisa; Tadokoro, Takahiro; Shu, Wataru; Hayashi, Takumi; O'hira, Shigeru; Nishi, Masataka

    2001-01-01

    Tritium decontamination using ultra violet (UV) lamp and laser was performed. Simulated co-deposited layer on tungsten substrate was deposited by C 2 H 2 or C 2 D 2 glow discharge. The co-deposited layer was irradiated to UV lights from a xenon excimer lamp (172 nm) or ArF excimer laser (193 nm) and the in-situ decontamination behavior was evaluated by a mass spectrometer. After the UV irradiation, the hydrogen concentration in the co-deposited layer was evaluated by elastic recoil detection analysis (ERDA) and the depth profile was analyzed by secondary ion mass spectrometry (SIMS). For the co-deposited layer formed by C 2 D 2 glow discharge, it was found that M/e 3 (HD) gas was released mainly during the UV lamp irradiation while both M/e 3 (HD) and M/e 4 (D 2 ) gases were detected during the UV laser irradiation. Though the co-deposited layer was not removed by UV lamp irradiation, almost all the co-deposited layer was removed by UV laser irradiation within 1 min. The ratio of hydrogen against carbon in the co-deposited layer was estimated to be 0.53 by ERDA and the number of photon needed for removing 1 μm thick co-deposited layer was calculated to be 3.7x10 18 cm -2 for the UV laser by SIMS measurement. It is concluded that C-H (C-D) bond on the co-deposited layer were dissociated by irradiation of UV lamp while the co-deposited layer itself was removed by the UV laser irradiation. (author)

  9. New lasers and light sources - old and new risks?

    DEFF Research Database (Denmark)

    Paasch, Uwe; Schwandt, Antje; Seeber, Nikolaus

    2017-01-01

    Recent developments (new wavelengths, treatment concepts, and combinations) in the field of lasers, intense pulsed light (IPL), LED, as well as new energy and light sources have opened up new therapeutic options that extend beyond mere aesthetic indications. Thus, while fractional lasers used...

  10. Development laser light facility for uranium isotope separation

    International Nuclear Information System (INIS)

    Dickinson, G.J.

    1992-01-01

    A laser light facility has been built and successfully commissioned as part of a programme to explore the economic potential of Laser Isotope Separation of Uranium. The laser systems are comprised of tunable dye lasers pumped by copper vapour lasers. The requirements for optical beam stability, alignment of lasers in chains, and protection of optical coatings have made challenging demands on the engineering design and operation of the facility. (Author)

  11. Remarkable enhancement on elimination reaction of side groups in excimer laser ablation of mixture targets of perylene derivatives with metal powder

    International Nuclear Information System (INIS)

    Nishio, Satoru; Tamura, Kazuyuki; Tsujine, Yukari; Fukao, Tomoko; Nakano, Masayoshi; Matsuzaki, Akiyoshi; Sato, Hiroyasu

    2002-01-01

    Films are deposited on substrates at 20 deg.C by excimer laser ablation (ELA) of mixture targets of 3,4,9,10-perylenetetracarboxylic dianhydride (PTCDA) with metal powder, PTCDA/M (M=Co, Ni, Fe, W, Cu and Ag) using XeCl and ArF beams. Large amount of fragments with ''naked'' perylene skeletons can be produced owing to effective elimination of carboxylic dianhydride groups by ELA of PTCDA/Co both with XeCl and ArF beams under optimized ablation conditions. Elimination reaction of side groups of PTCDA is observed for ELA of the targets with metal powder of the iron group, Co, Fe and Ni, especially remarkable for Co and Fe. The film from PTCDA/Ni consists of small particles with the various diameters ranging from 10 to 100 nm as well as that from PTCDA/Co. Morphology like petal of rose can be seen everywhere for the film from PTCDA/Fe

  12. New lasers and light sources - old and new risks?

    DEFF Research Database (Denmark)

    Paasch, Uwe; Schwandt, Antje; Seeber, Nikolaus

    2017-01-01

    Recent developments (new wavelengths, treatment concepts, and combinations) in the field of lasers, intense pulsed light (IPL), LED, as well as new energy and light sources have opened up new therapeutic options that extend beyond mere aesthetic indications. Thus, while fractional lasers used to ...

  13. NASA Laser Light Scattering Advanced Technology Development Workshop, 1988

    Science.gov (United States)

    Meyer, William V. (Editor)

    1989-01-01

    The major objective of the workshop was to explore the capabilities of existing and prospective laser light scattering hardware and to assess user requirements and needs for a laser light scattering instrument in a reduced gravity environment. The workshop addressed experimental needs and stressed hardware development.

  14. Applications of lasers and electro-optics

    International Nuclear Information System (INIS)

    Tan, B.C.; Low, K.S.; Chen, Y.H.; Harith bin Ahmad; Tou, T.Y.

    1994-01-01

    Supported by the IRPA Programme on Laser Technology and Applications, many types of lasers have been designed, constructed and applied in various areas of science, medicine and industries. Amongst these lasers constructed were high power carbon dioxide lasers, rare gas halide excimer lasers, solid state Neodymium-YAG lasers, nitrogen lasers, flashlamp pumped dye lasers and nitrogen and excimer laser pumped dye lasers. These lasers and the associated electro-optics system, some with computer controlled, are designed and developed for the following areas of applications: 1. Industrial applications of high power carbon dioxide lasers for making of i.c. components and other materials processing purposes. Prototype operational systems have been developed. 2. Medical applications of lasers for cancer treatment using the technique of photodynamic therapy. A new and more effective treatment protocol has been proposed. 3. Agricultural applications of lasers in palm oil and palm fruit-fluorescence diagnostic studies. Fruit ripeness signature has been developed and palm oil oxidation level were investigated. 4. Development of atmospheric pollution monitoring systems using laser lidar techniques. Laboratory scale systems were developed. 5. Other applications of lasers including laser holographic and interferometric methods for the non destructive testing of materials. The activities of the group (from 1988-1990) have resulted in the submission of a patent for a laser device, publication of many research paper sin local and overseas journals and conference proceedings, completion of 1 Ph.D. dissertation and 6 M. Phil theses. Currently (1991), a total of 3 Ph.D., 6 M. Phil research programmes are involved in this research and development programme

  15. Excimer laser phototherapeutic keratectomy in conjunction with mitomycin C in corneal macular and granular dystrophies

    Directory of Open Access Journals (Sweden)

    Erdem Yuksel

    2016-04-01

    Full Text Available ABSTRACT Purpose: To evaluate the visual outcomes, recurrence patterns, safety, and efficacy of excimer laser phototherapeutic keratectomy (PTK in conjunction with mitomycin C (MMC for corneal macular and granular diystrophies. Methods: The patients were divided into two groups. Group 1 included patients with macular corneal dystrophy (MCD that caused superficial corneal plaque opacities, and Group 2 included patients with granular corneal dystrophy (GCD. Patients in both groups were pre-, peri-, and postoperatively evaluated. The groups were compared in terms of uncorrected visual acuity (VA, best spectacle-corrected VA, presence of mild or significant recurrence, and time of recurrence. Results: Eighteen eyes (nine with MCD and nine with GCD of 18 patients (10 men and eight women were included. PTK was performed for each eye that was included in this study. The mean ablation amount was 117.8 ± 24.4 µm and 83.5 ± 45.7 µm in MCD and GCD, respectively, (p=0.18. The postoperative improvement of the mean VA was similar between the two groups before recurrences (p>0.43 and after recurrences (p>0.71. There were no statistically significant differences in the recurrence rate and the recurrence-free period for any recurrence type. Conclusion: PTK was an effective, safe, and minimally invasive procedure for patients with MCD and GCD. PTK in conjunction with MMC was similarly effective for both groups in terms of recurrence and visual outcomes.

  16. Theoretical interpretations of enhanced laser light absorption

    International Nuclear Information System (INIS)

    Kruer, W.L.

    1975-01-01

    Intense laser light is not efficiently absorbed classically but can be absorbed by its conversion to electron plasma waves near the critical density. The physical mechanisms for this conversion are discussed, and some simple estimates for heating by plasma waves are applied to some recent experiments. Several effects which strongly influence the absorption of high intensity light are emphasized, including a nonlinear steepening of the plasma density profile which is demonstrated in computer simulations. Finally the possibility of an induced reflection of laser light due to instabilities in the underdense plasma before the critical density is also discussed. Such stimulated reflection can be particularly important in plasmas with very long density gradients. (U.S.)

  17. How to harvest efficient laser from solar light

    Science.gov (United States)

    Zhao, Changming; Guan, Zhe; Zhang, Haiyang

    2018-02-01

    Solar Pumped Solid State Lasers (SPSSL) is a kind of solid state lasers that can transform solar light into laser directly, with the advantages of least energy transform procedure, higher energy transform efficiency, simpler structure, higher reliability, and longer lifetime, which is suitable for use in unmanned space system, for solar light is the only form of energy source in space. In order to increase the output power and improve the efficiency of SPSSL, we conducted intensive studies on the suitable laser material selection for solar pump, high efficiency/large aperture focusing optical system, the optimization of concave cavity as the second focusing system, laser material bonding and surface processing. Using bonded and grooved Nd:YAG rod as laser material, large aperture Fresnel lens as the first stage focusing element, concave cavity as the second stage focusing element, we finally got 32.1W/m2 collection efficiency, which is the highest collection efficiency in the world up to now.

  18. Laser Structuring of Thin Layers for Flexible Electronics by a Shock Wave-induced Delamination Process

    Science.gov (United States)

    Lorenz, Pierre; Ehrhardt, Martin; Zimmer, Klaus

    The defect-free laser-assisted structuring of thin films on flexible substrates is a challenge for laser methods. However, solving this problem exhibits an outstanding potential for a pioneering development of flexible electronics. Thereby, the laser-assisted delamination method has a great application potential. At the delamination process: the localized removal of the layer is induced by a shock wave which is produced by a laser ablation process on the rear side of the substrate. In this study, the thin-film patterning process is investigated for different polymer substrates dependent on the material and laser parameters using a KrF excimer laser. The resultant structures were studied by optical microscopy and white light interferometry (WLI). The delamination process was tested at different samples (indium tin oxide (ITO) on polyethylene terephthalate (PET), epoxy-based negative photoresist (SU8) on polyimide (PI) and indium tin oxide/copper indium gallium selenide/molybdenum (ITO/CIGS/Mo) on PI.

  19. Multi-MJ KrF laser driver for a 2050 IFE reactor

    International Nuclear Information System (INIS)

    Linford, G.J.C.

    1992-01-01

    This paper reports on a new design of a multi-megajoule KrF laser driver for the Prometheus inertial fusion energy (IFE) reactor c. year 2050 which has been developed exploiting advances achieved in non-linear optics (NLO) during the past decade. Optimized excimer e-beam sustained electric-discharge lasers (EBSEDLs) are predicted to produce output energies too low (∼4 kJ) with pulses too long (∼500 ns) to meet IFE target irradiation requirements ΔE target ∼ 5 MJ, τ target (∼ 6 ns). The NLO devices used in this design permit the independent optimization of excimer laser modules while providing the important functions of coherent beam combination, intensity smoothing, and temporal pulse compression at high efficiencies

  20. Laser etching of polymer masked leadframes

    Science.gov (United States)

    Ho, C. K.; Man, H. C.; Yue, T. M.; Yuen, C. W.

    1997-02-01

    A typical electroplating production line for the deposition of silver pattern on copper leadframes in the semiconductor industry involves twenty to twenty five steps of cleaning, pickling, plating, stripping etc. This complex production process occupies large floor space and has also a number of problems such as difficulty in the production of rubber masks and alignment, generation of toxic fumes, high cost of water consumption and sometimes uncertainty on the cleanliness of the surfaces to be plated. A novel laser patterning process is proposed in this paper which can replace many steps in the existing electroplating line. The proposed process involves the application of high speed laser etching techniques on leadframes which were protected with polymer coating. The desired pattern for silver electroplating is produced by laser ablation of the polymer coating. Excimer laser was found to be most effective for this process as it can expose a pattern of clean copper substrate which can be silver plated successfully. Previous working of Nd:YAG laser ablation showed that 1.06 μm radiation was not suitable for this etching process because a thin organic and transparent film remained on the laser etched region. The effect of excimer pulse frequency and energy density upon the removal rate of the polymer coating was studied.

  1. [Results of residual ametropia correction using CIRCLE technology after femtosecond laser SMILE surgery].

    Science.gov (United States)

    Kostin, O A; Rebrikov, S V; Ovchinnikov, A I; Stepanov, A A; Takhchidi, Kh P

    to evaluate functional results of reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser in cases of regression of the refractive effect after SMILE surgery. We studied a group of post-SMILE patients. In those, who showed regression of the refractive effect at 1 year, reoperation was performed according to the CIRCLE technology and using the VisuMax femtosecond laser. The corneal flap was separated from the stromal bed and turned aside. Excimer laser ablation of the stromal bed was performed with the MEL 80 machine. The corneal flap was then placed back and rinsed from both sides. Uncorrected (UCVA) and corrected (BCVA) visual acuity as well as spherical equivalent (SE) were estimated before reoperation, on day 1, and at 1 month. After reoperation, BCVA and UCVA improved. Patient refraction became close to emmetropia. Specifically, UCVA was 0.23±0.18 at baseline (i.e. 1 year after SMILE) and 0.93±0.11 after the CIRCLE procedure (pstatistically significant - from 0.95±0.1 to 0.93±0.11 (p>0.05). Reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser provides an increase in visual acuity in case of post-SMILE regression of the refractive effect.

  2. Laser-induced breakdown spectra of Zn2 molecule in the violet region

    Indian Academy of Sciences (India)

    The study of excimer and van der Waals molecules such as Hg2, Cd2 and Zn2 are of current interest as they are potential candidates for the possible development of new high power excimer lasers. Group IIB metal dimers (Hg2, Cd2 and Zn2) have essentially repulsive ground states with very shallow van der Walls minima.

  3. Laser assisted modification and chemical metallization of electron-beam deposited ceria thin films

    International Nuclear Information System (INIS)

    Krumov, E.; Starbov, N.; Starbova, K.; Perea, A.; Solis, J.

    2009-01-01

    Excimer laser processing is applied for tailoring the surface morphology and phase composition of CeO 2 ceramic thin films. E-beam evaporation technique is used to deposit samples on stainless steel and silicate glass substrates. The films are then irradiated with ArF* excimer laser pulses under different exposure conditions. Scanning electron microscopy, optical spectrophotometry, X-ray diffractometry and EDS microanalysis are used to characterize the non-irradiated and laser-processed films. Upon UV laser exposure there is large increase of the surface roughness that is accompanied by photo-darkening and ceria reduction. It is shown that the laser induced changes in the CeO 2 films facilitate the deposition of metal nano-aggregates in a commercial copper electroless plating bath. The significance of laser modification as a novel approach for the production of CeO 2 based thin film catalysts is discussed.

  4. Laser assisted modification and chemical metallization of electron-beam deposited ceria thin films

    Energy Technology Data Exchange (ETDEWEB)

    Krumov, E., E-mail: emodk@clf.bas.bg [Central Laboratory of Photoprocesses ' Acad. Jordan Malinowski' , Bulgarian Academy of Sciences, Acad. Georgy Bonchev Str., bl. 109, 1113 Sofia (Bulgaria); Starbov, N.; Starbova, K. [Central Laboratory of Photoprocesses ' Acad. Jordan Malinowski' , Bulgarian Academy of Sciences, Acad. Georgy Bonchev Str., bl. 109, 1113 Sofia (Bulgaria); Perea, A.; Solis, J. [Instituto de Optica ' Daza de Valdes' , CSIC, 28006 Madrid (Spain)

    2009-11-15

    Excimer laser processing is applied for tailoring the surface morphology and phase composition of CeO{sub 2} ceramic thin films. E-beam evaporation technique is used to deposit samples on stainless steel and silicate glass substrates. The films are then irradiated with ArF* excimer laser pulses under different exposure conditions. Scanning electron microscopy, optical spectrophotometry, X-ray diffractometry and EDS microanalysis are used to characterize the non-irradiated and laser-processed films. Upon UV laser exposure there is large increase of the surface roughness that is accompanied by photo-darkening and ceria reduction. It is shown that the laser induced changes in the CeO{sub 2} films facilitate the deposition of metal nano-aggregates in a commercial copper electroless plating bath. The significance of laser modification as a novel approach for the production of CeO{sub 2} based thin film catalysts is discussed.

  5. Configuration of organic dye excimers in nanoporous SiO2 matrices

    International Nuclear Information System (INIS)

    Sorokin, A.V.; Gnap, B.A.; Bespalova, I.I.; Yefimova, S.L.; Malyukin, Yu.V.

    2016-01-01

    The effect of cyanine dye 3,3′-dioctadecyloxacarbocyanine perchlorate (DiO) and benzimidazole dye 4-dimethylamino-1,8-naphthoylene-1′,2′-benzimidazole (DNBI) accumulation in nanoporous silica matrices on the dyes luminescence properties has been studied. For both dyes, ground state dimer formation with perpendicular transition dipoles at high dye concentrations has been considered as a result of restricted geometry of the nanoscale pores. The dimer excitation leads to excimer formation revealing by appearance of new long-wavelength luminescence band and shortening the dye luminescence lifetime. In the excimer luminescence excitation spectra two additional bands have been observed, one of which is bathochromically shifted relatively to the absorption band and another one is hypsocromically shifted. Using the Kasha exciton model it was shown that the excimers possess oblique transition dipoles configuration. - Highlights: • Organic dye molecules are efficiently accumulated in nanoporous silica matrices. • Restricted geometry of SiO 2 nanopores provokes excimerization of both cyanine and benzimidazole dyes. • The excimers reveal configuration of oblique dimers. • The excimers are originated from ground state dimers with a perpendicular arrangement of transition dipoles.

  6. Efficacy of fractional lasers in treating alopecia: a literature review.

    Science.gov (United States)

    Perper, Marina; Aldahan, Adam S; Fayne, Rachel A; Emerson, Christopher P; Nouri, Keyvan

    2017-11-01

    Hair loss stemming from different types of alopecia, such as androgenic alopecia and alopecia areata, negatively affects over half the population and, in many circumstances, causes serious psychosocial distress. Current treatment options for alopecia, such as minoxidil, anthralin, and intralesional corticosteroids, vary efficacy and side effect profiles. It is known that low-level laser/light therapies (LLLT), or photobiomodulations, such as the US FDA-cleared HairMax Lasercomb®, He-Ne laser, and excimer laser, are relatively affordable, user-friendly, safe, and effective forms of treatment for hair loss. While less is known about the effectiveness of fractional lasers for combating hair loss, research suggests that by creating microscopic thermal injury zones, fractional lasers may cause an increase in hair growth from a wound healing process, making them potential therapeutic options for alopecia. A literature review was performed to evaluate the effectiveness of fractional lasers on hair regrowth. The specific fractional laser therapies include the 1550-nm nonablative fractional erbium-glass laser, the ablative fractional 2940-nm erbium:YAG laser, and the ablative fractional CO 2 fractional laser. Additional randomized controlled trials are necessary to further evaluate the effectiveness of the lasers, as well as to establish appropriate parameters and treatment intervals.

  7. Laser applications in the electronics and optoelectronics industry in Japan

    Science.gov (United States)

    Washio, Kunihiko

    1999-07-01

    This paper explains current status and technological trends in laser materials processing applications in electronics and optoelectronics industry in Japan. Various laser equipment based on solid state lasers or gas lasers such as excimer lasers or CO2 lasers has been developed and applied in manufacturing electronic and optoelectronic devices to meet the strong demands for advanced device manufacturing technologies for high-performance, lightweight, low power-consumption portable digital electronic appliances, cellular mobile phones, personal computers, etc. Representative applications of solid-state lasers are, opaque and clear defects repairing of photomasks for LSIs and LCDs, trimming of thick-film chip resistors and low resistance metal resistors, laser cutting and drilling of thin films for high-pin count semiconductor CSP packages, laser patterning of thin-film amorphous silicon solar cells, and laser welding of electronic components such as hard-disk head suspensions, optical modules, miniature relays and lithium ion batteries. Compact and highly efficient diode- pumped and Q-switched solid-state lasers in second or third harmonic operation mode are now being increasingly incorporated in various laser equipment for fine material processing. Representative applications of excimer lasers are, sub-quarter micron design-rule LSI lithography and low- temperature annealing of poly-silicon TFT LCD.

  8. Nanoparticles and their tailoring with laser light

    International Nuclear Information System (INIS)

    Hubenthal, Frank

    2009-01-01

    Monodisperse noble metal nanoparticles are of tremendous interest for numerous applications, such as surface-enhanced Raman spectroscopy, catalysis or biosensing. However, preparation of monodisperse metal nanoparticles is still a challenging task, because typical preparation methods yield nanoparticle ensembles with broad shape and/or size distributions. To overcome this drawback, tailoring of metal nanoparticles with laser light has been developed, which is based on the pronounced shape- and size-dependent optical properties of metal nanoparticles. I will demonstrate that nanoparticle tailoring with ns-pulsed laser light is a suitable method to prepare nanoparticle ensembles with a narrow shape and/or size distribution. While irradiation with ns-pulsed laser light during nanoparticle growth permits a precise shape tailoring, post-grown irradiation allows a size tailoring. For example, the initial broad Gaussian size distribution of silver nanoparticles on quartz substrates with a standard deviation of σ= 30% is significantly reduced to as little as σ= 10% after tailoring. This paper addresses teachers of undergraduate and advanced school level as well as students. It assumes some fundamental knowledge in solid-state physics, thermodynamics and resonance vibration.

  9. Corneal photoablation in vivo with the erbium:YAG laser: first report

    Science.gov (United States)

    Jean, Benedikt J.; Bende, Thomas; Matallana, Michael; Kriegerowski, Martin

    1995-05-01

    As an alternative to far-UV lasers for corneal refractive surgery, the Erbium:YAG laser may be used in TEM00 mode. The resulting gaussian beam profile leads to a certain amount of myopic correction per laser pulse. Although animal data suggest that the clinical outcome should be comparable to the UV-lasers, no human data were available until now. We performed Erbium:YAG laser areal ablation in 5 blind human eyes. In TEM00 mode, the laser parameters were: effective diameter of laser spot equals 3.4 mm, fluence equals 380 mJ/cm2, pulse duration equals 250 microsecond(s) , Repetition rate equals 4 Hz, Number of applied laser pulses equals 15. Four patients with no light perception, one with intact light projection on one eye (some of them scheduled for enucleation) were treated under topical anaesthesia. Patient selection and informed consent were agreed to by the University's independent Ethics Committee. Prior to laser irradiation, corneal epithelium was removed. A postoperative silicone cast of the cornea was analyzed with a confocal laser micro-topometer for the ablation profile. The eyes were treated with antibiotic ointment until the epithelium was closed. Clinical appearance and, where possible, profilometry of the ablated area was observed. The ablation profile in cornea was gaussian shaped with a maximal depth of 30 micrometers . During laser treatment, the corneal surface becomes opaque, clearing in a matter of seconds. Epithelial healing and clinical appearance was similar to excimer laser treatment. However, during the first week, the irradiated area shows subepithelial irregularities, resembling small bubbles, disappearing thereafter.

  10. How predictable are the results of excimer laser photorefractive keratectomy? A review.

    Science.gov (United States)

    Grosvenor, T

    1995-10-01

    At the close of 1994, the AOA News reported that at least 14 companies were preparing to market equipment for excimer laser photorefractive keratectomy (PRK). More than a dozen PRK centers had been formed for the purpose of recruiting optometrists to co-manage PRK patients. Because the surgery is a "no-touch" computer-driven procedure whose duration is measured in seconds, the preoperative and postoperative care of PRK patients will assume major importance. Optometrists who will be asked to take part in the management of PRK patients must be able to counsel patients on matters such as the predictability of the procedure in terms of postoperative refractive error and visual acuity, as well as the possibility of unintended consequences such as difficulty in night driving. Information currently available, mainly as a result of studies conducted in other countries, shows that the results of PRK are highly predictable for preoperative myopia up to about -3.00 D and somewhat less predictable for myopia between -3.00 and -6.00 D, whereas for myopia greater than -6.00 D the probability of achieving a full correction decreases rapidly with increasing amounts of myopia. As compared to radial keratotomy (RK) in which the postoperative refractive error drifts relentlessly in the hyperopic direction, PRK brings about an initial hyperopic shift followed by regression leading to increasing myopia. Researchers disagree on the cause of the postoperative hyperopic shift and regression, and on the value of various methods of controlling regression including the use of wider and deeper ablation profiles and the postoperative use of corticosteroids and nonsteroid anti-inflammatory drugs. It is too early to determine whether the myopic creep in PRK will be as persistent as the hyperopic creep in RK, but it is likely that whereas presbyopic post-RK patients may have adequate distance vision but require corrective lenses for reading, presbyopic post-PRK patients may be sufficiently myopic

  11. Laser wakefield accelerator based light sources: potential applications and requirements

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). NIF and Photon Sciences; Thomas, A. G. [Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering and Radiological Sciences; Mangles, S. P.D. [Imperial College, London (United Kingdom). Blackett Lab.; Banerjee, S. [Univ. of Nebraska, Lincoln, NE (United States); Corde, S. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Flacco, A. [ENSTA, CNRS, Ecole Polytechnique, Palaiseau (France); Litos, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Neely, D. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Viera, J. [Univ. of Lisbon (Portugal). GoLP-Inst. de Plasmas e Fusao Nuclear-Lab. Associado; Najmudin, Z. [Imperial College, London (United Kingdom). Blackett Lab.; Bingham, R. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Joshi, C. [Univ. of California, Los Angeles, CA (United States). Dept. of Electrical Engineering; Katsouleas, T. [Duke Univ., Durham, NC (United States). Platt School of Engineering

    2015-01-15

    In this article we review the prospects of laser wakefield accelerators as next generation light sources for applications. This work arose as a result of discussions held at the 2013 Laser Plasma Accelerators Workshop. X-ray phase contrast imaging, X-ray absorption spectroscopy, and nuclear resonance fluorescence are highlighted as potential applications for laser-plasma based light sources. We discuss ongoing and future efforts to improve the properties of radiation from plasma betatron emission and Compton scattering using laser wakefield accelerators for these specific applications.

  12. Modes in light wave propagating in semiconductor laser

    Science.gov (United States)

    Manko, Margarita A.

    1994-01-01

    The study of semiconductor laser based on an analogy of the Schrodinger equation and an equation describing light wave propagation in nonhomogeneous medium is developed. The active region of semiconductor laser is considered as optical waveguide confining the electromagnetic field in the cross-section (x,y) and allowing waveguide propagation along the laser resonator (z). The mode structure is investigated taking into account the transversal and what is the important part of the suggested consideration longitudinal nonhomogeneity of the optical waveguide. It is shown that the Gaussian modes in the case correspond to spatial squeezing and correlation. Spatially squeezed two-mode structure of nonhomogeneous optical waveguide is given explicitly. Distribution of light among the laser discrete modes is presented. Properties of the spatially squeezed two-mode field are described. The analog of Franck-Condon principle for finding the maxima of the distribution function and the analog of Ramsauer effect for control of spatial distribution of laser emission are discussed.

  13. Plasmas and intense laser light

    International Nuclear Information System (INIS)

    Kennedy, E.T.

    1984-01-01

    The present article begins with a description of the laser technology required to reach the high irradiances of interest and provides a brief outline of the more important diagnostic techniques used in investigating the plasmas. An introduction to plasma waves is given and the linear and nonlinear excitation of waves is discussed. The remainder of the article describes some of the experimental evidence supporting the interpretation of the plasma behaviour at high laser-light intensities in terms of the excitation of plasma waves and the subsequent heating of plasma by these waves. (author)

  14. Intramolecular excimer and exciplex emission of 1,4-dipyrenyl substituted cyclohexasilane

    NARCIS (Netherlands)

    van Walree, C.A.; Kaats-Richters, V.E.M.; Jenneskens, L.W.; Williams, R.M.; van Stokkum, I.H.M.

    2002-01-01

    Intramolecular excimer emission is observed for cis-1,4-di(1-pyrenyl)decamethylcyclohexasilane in nonpolar solvents. Time-resolved fluorescence spectroscopy and kinetic modelling indicate that the driving force of excimer formation is very small, and that the process is governed by the flexibility

  15. CO2 laser-fabricated cladding light strippers for high-power fiber lasers and amplifiers.

    Science.gov (United States)

    Boyd, Keiron; Simakov, Nikita; Hemming, Alexander; Daniel, Jae; Swain, Robert; Mies, Eric; Rees, Simon; Andrew Clarkson, W; Haub, John

    2016-04-10

    We present and characterize a simple CO2 laser processing technique for the fabrication of compact all-glass optical fiber cladding light strippers. We investigate the cladding light loss as a function of radiation angle of incidence and demonstrate devices in a 400 μm diameter fiber with cladding losses of greater than 20 dB for a 7 cm device length. The core losses are also measured giving a loss of cladding light stripping of a 300 W laser diode with minimal heating of the fiber coating and packaging adhesives.

  16. Modeling of photoluminescence in laser-based lighting systems

    Science.gov (United States)

    Chatzizyrli, Elisavet; Tinne, Nadine; Lachmayer, Roland; Neumann, Jörg; Kracht, Dietmar

    2017-12-01

    The development of laser-based lighting systems has been the latest step towards a revolution in illumination technology brought about by solid-state lighting. Laser-activated remote phosphor systems produce white light sources with significantly higher luminance than LEDs. The weak point of such systems is often considered to be the conversion element. The high-intensity exciting laser beam in combination with the limited thermal conductivity of ceramic phosphor materials leads to thermal quenching, the phenomenon in which the emission efficiency decreases as temperature rises. For this reason, the aim of the presented study is the modeling of remote phosphor systems in order to investigate their thermal limitations and to calculate the parameters for optimizing the efficiency of such systems. The common approach to simulate remote phosphor systems utilizes a combination of different tools such as ray tracing algorithms and wave optics tools for describing the incident and converted light, whereas the modeling of the conversion process itself, i.e. photoluminescence, in most cases is circumvented by using the absorption and emission spectra of the phosphor material. In this study, we describe the processes involved in luminescence quantum-mechanically using the single-configurational-coordinate diagram as well as the Franck-Condon principle and propose a simulation model that incorporates the temperature dependence of these processes. Following an increasing awareness of climate change and environmental issues, the development of ecologically friendly lighting systems featuring low power consumption and high luminous efficiency is imperative more than ever. The better understanding of laser-based lighting systems is an important step towards that aim as they may improve on LEDs in the near future.

  17. The role of lasers and intense pulsed light technology in dermatology

    Directory of Open Access Journals (Sweden)

    Husain Z

    2016-02-01

    Full Text Available Zain Husain,1 Tina S Alster1,2 1Department of Dermatology, Georgetown University Hospital, 2Washington Institute of Dermatologic Laser Surgery, Washington, DC, USA Abstract: The role of light-based technologies in dermatology has expanded dramatically in recent years. Lasers and intense pulsed light have been used to safely and effectively treat a diverse array of cutaneous conditions, including vascular and pigmented lesions, tattoos, scars, and undesired hair, while also providing extensive therapeutic options for cosmetic rejuvenation and other dermatologic conditions. Dermatologic laser procedures are becoming increasingly popular worldwide, and demand for them has fueled new innovations and clinical applications. These systems continue to evolve and provide enhanced therapeutic outcomes with improved safety profiles. This review highlights the important roles and varied clinical applications that lasers and intense pulsed light play in the dermatologic practice. Keywords: laser, intense pulsed light, treatment, dermatology, technology

  18. Rapid prototyping of reflectors for vehicle lighting using laser activated remote phosphor

    Science.gov (United States)

    Lachmayer, Roland; Kloppenburg, Gerolf; Wolf, Alexander

    2015-03-01

    Bright white light sources are of significant importance for automotive front lighting systems. Today's upper class vehicles mainly use HID or LED as light source. As a further step in this development laser diode based systems offer high luminance, efficiency and allow the realization of new styling concepts and new dynamic lighting functions. These white laser diode systems can either be realized by mixing different spectral sources or by combining diodes with specific phosphors. Based on the approach of generating light using a laser and remote phosphor, lighting modules are manufactured. Four blue laser diodes (450 nm) are used to activate a phosphor coating and thus to achieve white light. A segmented paraboloid reflector generates the desired light distribution for an additional car headlamp. We use high speed milling and selective laser melting to build the reflector system for this lighting module. We compare the spectral reflection grade of these materials. Furthermore the generated modules are analyzed regarding their efficiency and light distribution. The use of Rapid Prototyping technologies allows an early validation of the chosen concept and is supposed to reduce cost and time in the product development process significantly. Therefor we discuss costs and times of the applied manufacturing technologies.

  19. Excimer Formation Dynamics of Dipyrenyldecane in Structurally Different Ionic Liquids.

    Science.gov (United States)

    Yadav, Anita; Pandey, Siddharth

    2017-12-07

    Ionic liquids, being composed of ions alone, may offer alternative pathways for molecular aggregation. These pathways could be controlled by the chemical structure of the cation and the anion of the ionic liquids. Intramolecular excimer formation dynamics of a bifluorophoric probe, 1,3-bis(1-pyrenyl)decane [1Py(10)1Py], where the fluorophoric pyrene moieties are separated by a long decyl chain, is investigated in seven different ionic liquids in 10-90 °C temperature range. The long alkyl separator allows for ample interaction with the solubilizing milieu prior to the formation of the excimer. The ionic liquids are composed of two sets, one having four ionic liquids of 1-butyl-3-methylimidazolium cation ([bmim + ]) with different anions and the other having four ionic liquids of bis(trifluoromethylsulfonyl)imide anion ([Tf 2 N - ]) with different cations. The excimer-to-monomer emission intensity ratio (I E /I M ) is found to increase with increasing temperature in sigmoidal fashion. Chemical structure of the ionic liquid controls the excimer formation efficiency, as I E /I M values within ionic liquids with the same viscosities are found to be significantly different. The excited-state intensity decay kinetics of 1Py(10)1Py in ionic liquids do not adhere to a simplistic Birk's scheme, where only one excimer conformer forms after excitation. The apparent rate constants of excimer formation (k a ) in highly viscous ionic liquids are an order of magnitude lower than those reported in organic solvents. In general, the higher the viscosity of the ionic liquid, the more sensitive is the k a to the temperature with higher activation energy, E a . The trend in E a is found to be similar to that for activation energy of the viscous flow (E a,η ). Stokes-Einstein relationship is not followed in [bmim + ] ionic liquids; however, with the exception of [choline][Tf 2 N], it is found to be followed in [Tf 2 N - ] ionic liquids suggesting the cyclization dynamics of 1Py(10)1Py

  20. Ponderomotive and thermal filamentation of laser light

    International Nuclear Information System (INIS)

    Kruer, W.L.

    1985-01-01

    As targets are irradiated with longer, more energetic pulses of laser light, longer-scalelength plasmas are produced. Filamentation is a potentially important process in such plasmas. In this instability, perturbations in the intensity profile of an incident light beam grow in amplitude, causing the beam to break up into intense filaments. The instability arises when a local increase in the light intensity creates a depression in plasma density either directly, via the ponderomotive force, or indirectly, via enhanced collisional absorption and subsequent plasma expansion. The density depression refracts the light into the lower-density region, enhancing the intensity perturbations. The instability is termed either ponderomotive or thermal filamentation, depending on which mechanism generates the density depression. The analogous process involving the entire beam is called self-focusing. Filamentation can significantly affect laser-plasma coupling. Intensity enhancements can introduce or modify other instabilities, change the location of the energy deposition, and possibly aggravate deleterious collective effects such as hot-electron generation

  1. EFFECT OF OPTICAL FIBER HYDROGEN LOADING ON THE INSCRIPTION EFFICIENCY OF CHIRPED BRAGG GRATINGS BY MEANS OF KrF EXCIMER LASER RADIATION

    Directory of Open Access Journals (Sweden)

    Sergey V. Varzhel

    2016-11-01

    Full Text Available Subject of Research.We present comparative results of the chirped Bragg gratings inscription efficiency in optical fiber of domestic production with and without low-temperature hydrogen loading. Method. Chirped fiber Bragg gratings inscription was made by the Talbot interferometer with chirped phase mask having a chirp rate of 2.3 nm/cm used for the laser beam amplitude separation. The excimer laser system Coherent COMPexPro 150T, working with the gas mixture KrF (248 nm, was used as the radiation source. In order to increase the UV photosensitivity, the optical fiber was placed in a chamber with hydrogen under a pressure of 10 MPa and kept there for 14 days at 40 °C. Main Results. The usage of the chirped phase mask in a Talbot interferometer scheme has made it possible to get a full width at half-maximum of the fiber Bragg grating reflection spectrum of 3.5 nm with induced diffraction structure length of 5 mm. By preliminary hydrogen loading of optical fiber the broad reflection spectrum fiber Bragg gratings with a reflectivity close to 100% has been inscribed. Practical Relevance. The resulting chirped fiber Bragg gratings can be used as dispersion compensators in optical fiber communications, as well as the reflective elements of distributed fiber-optic phase interferometric sensors.

  2. Excimer fluorescence of liquid crystalline systems

    Science.gov (United States)

    Sakhno, Tamara V.; Khakhel, Oleg A.; Barashkov, Nikolay N.; Korotkova, Irina V.

    1996-04-01

    The method of synchronous scanning fluorescence spectroscopy shows a presence of dimers of pyrene in a polymeric matrix. The results suggest that excimer formation takes place with dimers in liquid crystalline systems.

  3. Annual report to the Laser Facility Committee 1984

    International Nuclear Information System (INIS)

    1984-01-01

    The report describes the work carried out at, or in association with, the Central Laser Facility (CLF), during the year ending March 1984. The CLF programme is divided into three main sections. The first, the glass laser scientific programme, is concerned with applications of the high power Nd glass laser. The second, the ultra violet radiation facility scientific programme, involves the excimer pumped frequency tunable lasers. The last, high power KrF laser development, describes Research and development work on this laser. (U.K.)

  4. Tunable lasers for waste management photochemistry applications

    International Nuclear Information System (INIS)

    Finch, F.T.

    1978-09-01

    A review of lasers with potential photochemical applications in waste management indicates that dye lasers, as a class, can provide tunable laser output through the visible and near-uv regions of the spectrum of most interest to photochemistry. Many variables can affect the performance of a specific dye laser, and the interactions of these variables, at the current state of the art, are complex. The recent literature on dye-laser characteristics has been reviewed and summarized, with emphasis on those parameters that most likely will affect the scaling of dye lasers in photochemical applications. Current costs are reviewed and correlated with output power. A new class of efficient uv lasers that appear to be scalable in both energy output and pulse rate, based on rare-gas halide excimers and similar molecules, is certain to find major applications in photochemistry. Because the most important developments are too recent to be adequately described in the literature or are the likely outcome of current experiments, the basic physics underlying the class of excimer lasers is described. Specific cost data are unavailable, but these new gas lasers should reflect costs similar to those of existing gas lasers, in particular, the pulsed CO 2 lasers. To complete the survey of tunable-laser characteristics, the technical characteristics of the various classes of lasers in the ir are summarized. Important developments in ir laser technology are being accelerated by isotope-separation research, but, initially at least, this portion of the spectrum is least likely to receive emphasis in waste-management-oriented photochemistry

  5. UV laser engraving of high temperature polymeric materials

    International Nuclear Information System (INIS)

    Martinez, D.; Laude, L.D.; Kolev, K.; Hanus, F.

    1999-01-01

    Among emerging technologies, those associated with laser sources as surface processing tools are quite promising. In the present work, a UV pulsed (excimer) laser source is experimented for engraving (or ablating) polymeric materials based on three high temperature polymers: polyethylene terephtalate (PET), polyethersulfone (PES) and polyphenylene sulfide (PPS). The ablation phenomenon is demonstrated on all these polymers and evaluated by stylus profilometry upon varying the laser fluence at impact. For each polymer, results give evidence for three characteristic quantities: an ablation threshold E sub 0, a maximum ablation depth per pulse z sub 0 and an initial rate of ablation α, just above threshold. A simple ablation model is presented which describes correctly the observed behaviours and associates closely the above quantities to the polymer formulation, thus providing for the first time a rational basis to polymer ablation. The model may be extended to parent plastic materials whenever containing the same polymers. It may also be used to predict the behaviours of other polymers when subjected to excimer laser irradiation

  6. Bulk damage and absorption in fused silica due to high-power laser applications

    Science.gov (United States)

    Nürnberg, F.; Kühn, B.; Langner, A.; Altwein, M.; Schötz, G.; Takke, R.; Thomas, S.; Vydra, J.

    2015-11-01

    Laser fusion projects are heading for IR optics with high broadband transmission, high shock and temperature resistance, long laser durability, and best purity. For this application, fused silica is an excellent choice. The energy density threshold on IR laser optics is mainly influenced by the purity and homogeneity of the fused silica. The absorption behavior regarding the hydroxyl content was studied for various synthetic fused silica grades. The main absorption influenced by OH vibrational excitation leads to different IR attenuations for OH-rich and low-OH fused silica. Industrial laser systems aim for the maximum energy extraction possible. Heraeus Quarzglas developed an Yb-doped fused silica fiber to support this growing market. But the performance of laser welding and cutting systems is fundamentally limited by beam quality and stability of focus. Since absorption in the optical components of optical systems has a detrimental effect on the laser focus shift, the beam energy loss and the resulting heating has to be minimized both in the bulk materials and at the coated surfaces. In collaboration with a laser research institute, an optical finisher and end users, photo thermal absorption measurements on coated samples of different fused silica grades were performed to investigate the influence of basic material properties on the absorption level. High purity, synthetic fused silica is as well the material of choice for optical components designed for DUV applications (wavelength range 160 nm - 260 nm). For higher light intensities, e.g. provided by Excimer lasers, UV photons may generate defect centers that effect the optical properties during usage, resulting in an aging of the optical components (UV radiation damage). Powerful Excimer lasers require optical materials that can withstand photon energy close to the band gap and the high intensity of the short pulse length. The UV transmission loss is restricted to the DUV wavelength range below 300 nm and

  7. Influence of laser surface modifying of polyethylene terephthalate on fibroblast cell adhesion

    International Nuclear Information System (INIS)

    Mirzadeh, H.; Dadsetan, M.

    2003-01-01

    Attempts have been made to evaluate the changes in physical and chemical properties of the polyethylene terephthalate (PET) surface due to laser irradiation. These changes have been investigated from viewpoints of microstructuring and its effect on fibroblast cell behavior. The surfaces of PET were irradiated using CO 2 and KrF excimer pulsed laser. The changes were characterized by attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, scanning electron microscopy (SEM) and contact angle measurements. The data from ATR-FTIR spectra showed that the crystallinity in the surface region decreased due to the CO 2 and excimer laser irradiation. SEM observations showed that specific microstructures were created on the PET surface due to laser irradiation. In order to study biocompatibility and cell behavior, we utilized standard in vitro L929-fibroblast cell culture system. Fibroblast cell adhesion and spreading were significantly correlated to the morphology and wettability of the laser irradiated PET surface

  8. Study of laser plasma emission from doped targets

    Czech Academy of Sciences Publication Activity Database

    Velardi, L.; Krása, Josef; Velyhan, Andriy; Nassisi, V.

    2012-01-01

    Roč. 83, č. 2 (2012), , "02B911-1"-"02B911-3" ISSN 0034-6748 R&D Projects: GA MŠk(CZ) 7E09092; GA MŠk(CZ) LC528 EU Projects: European Commission(XE) 228334 - LASERLAB-EUROPE Institutional research plan: CEZ:AV0Z10100523 Keywords : copper * excimer lasers * ion mobility * krypton compounds * laser ablation Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.602, year: 2012

  9. Ultraviolet-laser ablation of skin

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R.J.; Linsker, R.; Wynne, J.J.; Torres, A.; Geronemus, R.G.

    1985-05-01

    The authors report on the use of pulsed ultraviolet-laser irradiation at 193 nm from an argon-fluoride laser and at 248 nm from a krypton-fluoride laser to ablate skin. In vitro, both wavelengths performed comparably, removing tissue precisely and cleanly, and leaving minimal thermal damage to the surrounding tissue. In vivo, the 193-nm laser radiation failed to remove tissue after bleeding began. The 248-nm radiation, however, continued to remove tissue despite bleeding and left a clean incision with only minimal thermal damage. The krypton-fluoride excimer laser beam at 248 nm, which should be deliverable through a quartz optical fiber, has great potential as a surgical instrument.

  10. Excimer laser micropatterning of freestanding thermo-responsive hydrogel layers for cells-on-chip applications

    International Nuclear Information System (INIS)

    Santaniello, Tommaso; Milani, Paolo; Lenardi, Cristina; Martello, Federico; Tocchio, Alessandro; Gassa, Federico; Webb, Patrick

    2012-01-01

    We report a novel reliable and repeatable technologic manufacturing protocol for the realization of micro-patterned freestanding hydrogel layers based on thermo-responsive poly-(N-isopropyl)acrylamide (PNIPAAm), which have potential to be employed as temperature-triggered smart surfaces for cells-on-chip applications. PNIPAAm-based films with controlled mechanical properties and different thicknesses (100–300 µm thickness) were prepared by injection compression moulding at room temperature. A 9 × 9 array of 20 µm diameter through-holes is machined by means of the KrF excimer laser on dry PNIPAAm films which are physically attached to flat polyvinyl chloride (PVC) substrates. Machining parameters, such as fluence and number of shots, are optimized in order to achieve highly resolved features. Micro-structured freestanding films are then easily obtained after hydrogels are detached from PVC by gradually promoting the film swelling in ethanol. In the PNIPAAm water-swollen state, the machined holes’ diameter approaches a slight larger value (30 µm) according to the measured hydrogel swelling ratio. Thermo-responsive behaviour and through-hole tapering characterization are carried out by metrology measurements using an optical inverted and confocal microscope setup, respectively. After the temperature of freestanding films is raised above 32 °C, we observe that the shrinkage of the whole through-hole array occurs, thus reducing the holes’ diameter to less than a half its original size (about 15 µm) as a consequence of the film dehydration. Different holes’ diameters (10 and 30 µm) are also obtained on dry hydrogel employing suitable projection masks, showing similar shrinking behaviour when hydrated and undergone thermo-response tests. Thermo-responsive PNIPAAm-based freestanding layers could then be integrated with other suitable micro-fabricated thermoplastic components in order to preliminary test their feasibility in operating as temperature

  11. Changes of retinal light sensitivity after YAG-laser capsulotomy

    International Nuclear Information System (INIS)

    Pahor, D.; Gracner, B.

    2003-01-01

    The aim of this prospective study was to investigate the changes of retinal light sensitivity of central visual field in patients with posterior capsule opacification (PCO) after YAG-laser capsulotomy. Our study includes 18 eyes ( 18 patients) with PCO after phacoemulsification and intraocular lens implantation. In all patients YAG-laser capsulotomy was performed. In all patients, a threshold visual field analysis was carried out with the C 30-2 program of the automated Humphrey Field Analyzer before and one month after the procedure. In all patients a significant improvement of visual acuity was observed one month after capsulotomy (p 0.00004). One month after YAG-laser treatment, a significant improvement of retinal light sensitivity in the central visual field was also observed. The average MD (mean deviation) before the procedure was -6.88 db (±3.9, max. -11.7, min. 2.17) and after the procedure --4.58 db (±4.37, max. -10.87, min. +0.51). The improvement in MD was statistically significant (p = 0.00475). No correlation was established between the improvement of retinal light sensitivity and patient age or the size of capsulotomy. Our study shows that the improvement of retinal light sensitivity is significant after YAG-laser capsulotomy and does not depend on patient age or capsulotomy size. (author)

  12. Two-photon equivalent weighting of spatial excimer laser beam profiles

    Science.gov (United States)

    Eva, Eric; Bauer, Harry H.; Metzger, K.; Pfeiffer, A.

    2001-04-01

    Damage in optical materials for semiconductor lithography applications caused by exposure to 248 or 193 nm light is usually two-photon driven, hence it is a nonlinear function of incident intensity. Materials should be tested with flat- topped temporal and spatial laser beam profiles to facilitate interpretation of data, but in reality this is hard to achieve. Sandstrom provided a formula that approximates any given temporal pulse shape with a two- photon equivalent rectangular pulse (Second Symposium on 193 nm Lithography, Colorado Springs 1997). Known as the integral-square pulse duration, this definition has been embraced as an industry standard. Originally faced with the problem of comparing results obtained with pseudo-Gaussian spatial profiles to literature data, we found that a general solution for arbitrarily inhomogeneous spatial beam profiles exists which results in a definition much similar to Sandstrom's. In addition, we proved the validity of our approach in experiments with intentionally altered beam profiles.

  13. Effects of DC gate and drain bias stresses on the degradation of excimer laser crystallized polysilicon thin film transistors

    International Nuclear Information System (INIS)

    Kouvatsos, D N; Michalas, L; Voutsas, A T; Papaioannou, G J

    2005-01-01

    The effects of gate and drain bias stresses on thin film transistors fabricated in polysilicon films crystallized using the advanced sequential lateral solidification excimer laser annealing (SLS ELA) process, which yields very elongated polysilicon grains and allows the fabrication of TFTs without grain boundary barriers to current flow, are investigated as a function of the active layer thickness and of the TFT orientation relative to the grains. The application of hot carrier stress, with a condition of V GS = V DS /2, was determined to induce threshold voltage, subthreshold swing and transconductance degradation for TFTs in thicker polysilicon films and the associated stress-induced increase in the active layer trap density was evaluated. However, this device degradation was drastically reduced for TFTs fabricated in ultra-thin films. Furthermore, the application of the same stress condition to TFTs oriented vertically to the elongated grains resulted in similar threshold voltage shift but in substantially decreased subthreshold swing and transconductance degradation. The immunity of ultra-thin active layer devices to degradation under hot carrier stress clearly suggests the implementation of ultra thin SLS ELA polysilicon films for the fabrication of TFTs exhibiting not only high performance but, especially, the high reliability needed for integrated systems on panel

  14. Impact of mismatched and misaligned laser light sheet profiles on PIV performance

    Science.gov (United States)

    Grayson, K.; de Silva, C. M.; Hutchins, N.; Marusic, I.

    2018-01-01

    The effect of mismatched or misaligned laser light sheet profiles on the quality of particle image velocimetry (PIV) results is considered in this study. Light sheet profiles with differing widths, shapes, or alignment can reduce the correlation between PIV images and increase experimental errors. Systematic PIV simulations isolate these behaviours to assess the sensitivity and implications of light sheet mismatch on measurements. The simulations in this work use flow fields from a turbulent boundary layer; however, the behaviours and impacts of laser profile mismatch are highly relevant to any fluid flow or PIV application. Experimental measurements from a turbulent boundary layer facility are incorporated, as well as additional simulations matched to experimental image characteristics, to validate the synthetic image analysis. Experimental laser profiles are captured using a modular laser profiling camera, designed to quantify the distribution of laser light sheet intensities and inform any corrective adjustments to an experimental configuration. Results suggest that an offset of just 1.35 standard deviations in the Gaussian light sheet intensity distributions can cause a 40% reduction in the average correlation coefficient and a 45% increase in spurious vectors. Errors in measured flow statistics are also amplified when two successive laser profiles are no longer well matched in alignment or intensity distribution. Consequently, an awareness of how laser light sheet overlap influences PIV results can guide faster setup of an experiment, as well as achieve superior experimental measurements.

  15. Formation and control of excimer of a coumarin derivative in Langmuir–Blodgett films

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Santanu; Bhattacharjee, D.; Hussain, Syed Arshad, E-mail: sa_h153@hotmail.com

    2014-01-15

    In this communication we report the formation and control of excimer of a coumerin derivative 7-Hydroxy-N-Octadecyl Coumarin-3-Carboxamide (7HNO3C) assembled onto Langmuir–Blodgett (LB) films. Surface pressure–area per molecule isotherm revealed that 7HNO3C formed stable Langmuir monolayer at the air–water interface. Spectroscoipic characterizations confirmed the formation of excimer of 7HNO3C in the LB film prepared at 20 mN/m surface pressure. The excimer band remains present even when 7HNO3C molecules are diluted with a long chain fatty acid stearic acid in LB films. The excimer formation of 7HNO3C can be controlled by incorporating clay particle laponite in the LB film. The excimer band is totally absent in the hybrid 7HNO3C–laponite LB films. In-situ fluorescence imaging microscopy and atomic force microscopy confirmed the incorporation of clay laponite onto LB films. -- Highlights: • Formation of Langmuir monolayer and Langmuir–Blodgett (LB) film of a coumarin derivative. • Presence of excimeric species in the LB film lifted at 20 mN/m surface pressure is confirmed from the spectroscopic studies. • Control of excimer formation by incorporating clay particle laponite on to the LB film. • In-situ fluorescence imaging microscopy and atomic force microscopy confirmed the incorporation of clay laponite onto LB films.

  16. Perovskite Materials for Light-Emitting Diodes and Lasers.

    Science.gov (United States)

    Veldhuis, Sjoerd A; Boix, Pablo P; Yantara, Natalia; Li, Mingjie; Sum, Tze Chien; Mathews, Nripan; Mhaisalkar, Subodh G

    2016-08-01

    Organic-inorganic hybrid perovskites have cemented their position as an exceptional class of optoelectronic materials thanks to record photovoltaic efficiencies of 22.1%, as well as promising demonstrations of light-emitting diodes, lasers, and light-emitting transistors. Perovskite materials with photoluminescence quantum yields close to 100% and perovskite light-emitting diodes with external quantum efficiencies of 8% and current efficiencies of 43 cd A(-1) have been achieved. Although perovskite light-emitting devices are yet to become industrially relevant, in merely two years these devices have achieved the brightness and efficiencies that organic light-emitting diodes accomplished in two decades. Further advances will rely decisively on the multitude of compositional, structural variants that enable the formation of lower-dimensionality layered and three-dimensional perovskites, nanostructures, charge-transport materials, and device processing with architectural innovations. Here, the rapid advancements in perovskite light-emitting devices and lasers are reviewed. The key challenges in materials development, device fabrication, operational stability are addressed, and an outlook is presented that will address market viability of perovskite light-emitting devices. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Temporally coherent x-ray laser with the high order harmonic light

    International Nuclear Information System (INIS)

    Hasegawa, Noboru; Kawachi, Tetsuya; Kishimoto, Maki; Sukegawa, Kouta; Tanaka, Momoko; Ochi, Yoshihiro; Nishikino, Masaharu; Kawazome, Hayato; Nagashima, Keisuke

    2005-01-01

    We obtained the neon-like manganese x-ray laser with the injection of the high order harmonic light as the seed x-ray at the wavelength of 26.9 nm for the purpose of generation of the temporally coherent x-ray laser. The x-ray amplifier, which has quite narrow spectral width, selected and amplified the temporally coherent mode of the harmonic light. The temporal coherence of the mode selected harmonic light was nearly transform limited pulse, and the obtained x-ray laser with the seed x-ray expected to be nearly temporally coherent x-ray. (author)

  18. Preliminary results of tracked photorefractive keratectomy (T-PRK) for mild to moderate myopia with the autonomous technologies excimer laser at Cedars-Sinai Medical Center

    Science.gov (United States)

    Maguen, Ezra I.; Salz, James J.; Nesburn, Anthony B.

    1997-05-01

    Preliminary results of the correction of myopia up to -7.00 D by tracked photorefractive keratectomy (T-PRK) with a scanning and tracking excimer laser by Autonomous Technologies are discussed. 41 eyes participated (20 males). 28 eyes were evaluated one month postop. At epithelization day mean uncorrected vision was 20/45.3. At one month postop, 92.8 of eyes were 20/40 and 46.4% were 20/20. No eye was worse than 20/50. 75% of eyes were within +/- 0.5 D of emmetropia and 82% were within +/- 1.00 D of emmetropia. Eyes corrected for monovision were included. One eye lost 3 lines of best corrected vision, and had more than 1.00 D induced astigmatism due to a central corneal ulcer. Additional complications included symptomatic recurrent corneal erosions which were controlled with topical hypertonic saline. T-PRK appears to allow effective correction of low to moderate myopia. Further study will establish safety and efficacy of the procedure.

  19. Investigation of rf plasma light sources for dye laser excitation

    International Nuclear Information System (INIS)

    Kendall, J.S.; Jaminet, J.F.

    1975-06-01

    Analytical and experimental studies were performed to assess the applicability of radio frequency (rf) induction heated plasma light sources for potential excitation of continuous dye lasers. Experimental efforts were directed toward development of a continuous light source having spectral flux and emission characteristics approaching that required for pumping organic dye lasers. Analytical studies were performed to investigate (1) methods of pulsing the light source to obtain higher radiant intensity and (2) methods of integrating the source with a reflective cavity for pumping a dye cell. (TFD)

  20. EMERGING TECHNOLOGY PROJECT BULLETIN: LASER INDUCED PHOTOCHEMICAL OXIDATIVE DESTRUCTION

    Science.gov (United States)

    The process developed by Energy and Environmental Engineering, Incorporated, is designed to photochemically oxidize organic compounds in wastewater by applying ultraviolet radiation using an Excimer laser. The photochemical reactor can destroy low to moderate concentrations...

  1. Laser in operative dentistry

    Directory of Open Access Journals (Sweden)

    E. Yasini

    1994-06-01

    Full Text Available Today laser has a lot of usage in medicine and dentistry. In the field of dentistry, laser is used in soft tissue surgery, sterilization of canals (in root canal therapy and in restorative dentistry laser is used for cavity preparation, caries removal, sealing the grooves (in preventive dentistry, etching enamel and dentin, composite polymerization and removal of tooth sensitivity. The use of Co2 lasers and Nd: YAG for cavity preparation, due to creating high heat causes darkness and cracks around the region of laser radiation. Also due to high temperature of these lasers, pulp damage is inevitable. So today, by using the Excimer laser especially the argon floride type with a wavelength of 193 nm, the problem of heat stress have been solved, but the use of lasers in dentistry, especially for cavity preparation needs more researches and evaluations.

  2. The 'Magic Light': A Discussion on Laser Ethics.

    Science.gov (United States)

    Stylianou, Andreas; Talias, Michael A

    2015-08-01

    Innovations in technology and science form novel fields that, although beneficial, introduce new bio-ethical issues. In their short history, lasers have greatly influenced our everyday lives, especially in medicine. This paper focuses particularly on medical and para-medical laser ethics and their origins, and presents the complex relationships within laser ethics through a three-dimensional matrix model. The term 'laser' and the myth of the 'magic light' can be identified as landmarks for laser related ethical issues. These ethical issues are divided into five major groups: (1) media, marketing, and advertising; (2) economic outcomes; (3) user training; (4) the user-patient/client relationship; and (5) other issues. In addition, issues arising from two of the most common applications of lasers, laser eye surgery and laser tattoo removal, are discussed. The aim of this paper is to demonstrate that the use of medical and para-medical lasers has so greatly influenced our lives that the scientific community must initiate an earnest discussion of medical laser ethics.

  3. High coupling efficiency of foam spherical hohlraum driven by 2ω laser light

    Science.gov (United States)

    Chen, Yao-Hua; Lan, Ke; Zheng, Wanguo; Campbell, E. M.

    2018-02-01

    The majority of solid state laser facilities built for laser fusion research irradiate targets with third harmonic light (0.35 μm) up-converted from the fundamental Nd wavelength at 1.05 μm. The motivation for this choice of wavelength is improved laser-plasma coupling. Significant disadvantages to this choice of wavelength are the reduced damage threshold of optical components and the efficiency of energy conversion to third harmonic light. Both these issues are significantly improved if second harmonic (0.53 μm) radiation is used, but theory and experiments have shown lower optical to x-ray energy conversion efficiency and increased levels of laser-plasma instabilities, resulting in reduced laser-target coupling. In this letter, we propose to use a 0.53 μm laser for the laser ignition facilities and use a low density foam wall to increase the coupling efficiency from the laser to the capsule and present two-dimensional radiation-hydrodynamic simulations of 0.53 μm laser light irradiating an octahedral-spherical hohlraum with a low density foam wall. The simulations show that the reduced optical depth of the foam wall leads to an increased laser-light conversion into thermal x-rays and about 10% higher radiation flux on the capsule than that achieved with 0.35 μm light irradiating a solid density wall commonly used in laser indirect drive fusion research. The details of the simulations and their implications and suggestions for wavelength scaling coupled with innovative hohlraum designs will be discussed.

  4. Pulsed laser deposition of semiconductor-ITO composite films on electric-field-applied substrates

    International Nuclear Information System (INIS)

    Narazaki, Aiko; Sato, Tadatake; Kawaguchi, Yoshizo; Niino, Hiroyuki; Yabe, Akira; Sasaki, Takeshi; Koshizaki, Naoto

    2002-01-01

    The DC electric-field effect on the crystallinity of II-VI semiconductor in composite systems has been investigated for CdS-ITO films fabricated via alternative pulsed laser deposition (PLD) of CdS and indium tin oxide (ITO) on electric-field-applied substrates. The alternative laser ablation was performed under irradiation of ArF excimer laser in mixture gas of helium and oxygen. The application of electric-field facilitated the preferential crystal-growth of CdS in nanometer scale at low pressure, whereas all the films grown without the field were amorphous. There is a large difference in the crystallization between the films grown on field-applied and heated substrates; the latter showed the crystal-growth with random orientations. This difference indicates that the existence of electric-field has an influence on the transformation from amorphous to crystalline phase of CdS. The driving force for the field-induced crystallization is also discussed in the light of the Joule heat

  5. Spectral blueshifts in laser light scattered from argon-gas-cluster plasmas

    International Nuclear Information System (INIS)

    Singhal, H.; Arora, V.; Naik, P.A.; Gupta, P.D.

    2005-01-01

    An experimental study is presented on scattering of laser light from argon gas clusters irradiated by multipicosecond Nd:glass laser pulses at moderate intensity of 10 15 W/cm 2 . Space-resolved side-scattered laser light has a predominantly blueshifted and broadened spectrum (up to ∼8 nm). The scattered signal intensity and average blueshift exhibit a marked dependence on the backing pressure of the gas. The results are explained by self-phase modulation of the laser radiation due to changing polarizability as the heated clusters pass through resonance at 3 times the critical density during which intense absorption and scattering occurs. The observed blueshift may be useful in diagnostics of this important phase of laser-cluster interactions

  6. Organelle-specific injury to melanin-containing cells in human skin by pulsed laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, G.F.; Shepard, R.S.; Paul, B.S.; Menkes, A.; Anderson, R.R.; Parrish, J.A.

    1983-12-01

    Physical models predict that ultraviolet laser radiation of appropriately brief pulses can selectively alter melanin-containing cellular targets in human skin. Skin of normal human volunteers was exposed to brief (20 nanosecond) 351-nm wave length pulses from a XeF excimer laser, predicting that those cells containing the greatest quantities of melanized melanosomes (lower half of the epidermis) would be selectively damaged. Transmission electron microscopy revealed the earliest cellular alteration to be immediate disruption of melanosomes, both within melanocytes and basal keratinocytes. This disruption was dose dependent and culminated in striking degenerative changes in these cells. Superficial keratinocytes and Langerhans cells were not affected. It was concluded that the XeF excimer laser is capable of organelle-specific injury to melanosomes. These findings may have important clinical implications in the treatment of both benign and malignant pigmented lesions by laser radiations of defined wave lengths and pulse durations.

  7. Laser Thomson scattering diagnostics of non-equilibrium high pressure plasmas

    International Nuclear Information System (INIS)

    Muraoka, K.; Uchino, K.; Bowden, M.D.; Noguchi, Y.

    2001-01-01

    For various applications of non-equilibrium high pressure plasmas, knowledge of electron properties, such as electron density, electron temperature and/or electron energy distribution function (eedf), is prerequisite for any rational approach to understanding physical and chemical processes occurring in the plasmas. For this purpose, laser Thomson scattering has been successfully applied for the first time to measure the electron properties in plasmas for excimer laser pumping and in microdischarges. Although this diagnostic technique is well established for measurements in high temperature plasmas, its applications to these glow discharge plasmas have had various inherent difficulties, such as a presence of high density neutral particles (>10 21 m -3 ) in the excimer laser pumping discharges and an extremely small plasma size (<0.1 mm) and the presence of nearby walls for microdischarges. These difficulties have been overcome and clear signals have been obtained. The measured results are presented and their implications in the respective discharge phenomena are discussed

  8. Suppressed speckle contrast of blue light emission out of white lamp with phosphors excited by blue laser diodes for high-brightness lighting applications

    Science.gov (United States)

    Kinoshita, Junichi; Ikeda, Yoshihisa; Takeda, Yuji; Ueno, Misaki; Kawasaki, Yoji; Matsuba, Yoshiaki; Heike, Atsushi

    2012-11-01

    The speckle contrast of blue light emission out of high-brightness white lamps using phosphors excited by InGaN/GaN blue laser diodes is evaluated as a measure of coherence. As a result, speckle contrast of as low as 1.7%, the same level as a blue light emitting diode, is obtained. This implies that the original blue laser light can be converted into incoherent light through lamp structures without any dynamic mechanisms. This unique speckle-free performance is considered to be realized by multiple scattering inside the lamp structure, the multi-longitudinal mode operation of the blue laser diodes, and the use of multiple laser diodes. Such almost-incoherent white lamps can be applied for general lighting without any nuisance of speckle noise and should be categorized as lamps rather than lasers in terms of laser safety regulation.

  9. Laser subepithelial keratomileusis for myopia of -6 to -10 diopters with astigmatism with the MEL60 laser.

    Science.gov (United States)

    Bilgihan, Kamil; Hondur, Ahmet; Hasanreisoglu, Berati

    2004-01-01

    To evaluate the efficacy, predictability, and safety of laser subepithelial keratomileusis (LASEK) for treatment of high myopia with astigmatism. LASEK was performed in 61 eyes of 36 consecutive patients with myopic spherical equivalent refraction of -6.00 to -10.00 D using the Aesculap-Meditec MEL60 excimer laser. Data were collected prospectively with a follow-up of 6 to 17 months. Main outcome measures recorded were UCVA, BSCVA, residual refractive error, corneal haze, and complications. Ninety-six percent of eyes achieved 20/40 or better UCVA at 1 month. At 12 months, 64% of eyes achieved 20/20 and 92% achieved 20/40 or better UCVA. Two eyes lost 2 lines of BSCVA at 6 or 12 months. Accuracy of correction was +/- 0.50 D from emmetropia in 82% of eyes, and +/- 1.00 D in 90% at 12 months. No eye showed more than grade 1 haze. Grade 1 haze was observed in three eyes at 12 months. One patient had mild postoperative keratitis, which was successfully treated. LASEK with the Aesculap-Meditec MEL60 excimer laser appeared to be safe, effective, and highly predictable in treating high myopia.

  10. Development of laser materials processing and laser metrology techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Chung, Chin Man; Kim, Jeong Mook; Kim, Min Suk; Kim, Kwang Suk; Baik, Sung Hoon; Kim, Seong Ouk; Park, Seung Kyu

    1997-09-01

    The applications of remote laser materials processing and metrology have been investigated in nuclear industry from the beginning of laser invention because they can reduce the risks of workers in the hostile environment by remote operation. The objective of this project is the development of laser material processing and metrology techniques for repairing and inspection to improve the safety of nuclear power plants. As to repairing, we developed our own laser sleeve welding head and innovative optical laser weld monitoring techniques to control the sleeve welding process. Furthermore, we designed and fabricated a 800 W Nd:YAG and a 150 W Excimer laser systems for high power laser materials processing in nuclear industry such as cladding and decontamination. As to inspection, we developed an ESPI and a laser triangulation 3-D profile measurement system for defect detection which can complement ECT and UT inspections. We also developed a scanning laser vibrometer for remote vibration measurement of large structures and tested its performance. (author). 58 refs., 16 tabs., 137 figs

  11. Chromatin damage induced by fast neutrons or UV laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    Radu, L.; Constantinescu, B.; Gazdaru, D.; Mihailescu, I

    2002-07-01

    Chromatin samples from livers of Wistar rats were subjected to fast neutron irradiation in doses of 10-100 Gy or to a 248 nm excimer laser radiation, in doses of 0.5-3 MJ.m{sup -2}. The action of the radiation on chromatin was monitored by chromatin intrinsic fluorescence and fluorescence lifetimes (of bound ethidium bromide to chromatin) and by analysing fluorescence resonance energy transfer between dansyl chloride and acridine orange coupled to chromatin. For the mentioned doses of UV excimer laser radiation, the action on chromatin was more intense than in the case of fast neutrons. The same types of damage are produced by the two radiations: acidic and basic destruction of chromatin protein structure, DNA strand breaking and the increase of the distance between DNA and proteins in chromatin. (author)

  12. Chromatin damage induced by fast neutrons or UV laser radiation

    International Nuclear Information System (INIS)

    Radu, L.; Constantinescu, B.; Gazdaru, D.; Mihailescu, I.

    2002-01-01

    Chromatin samples from livers of Wistar rats were subjected to fast neutron irradiation in doses of 10-100 Gy or to a 248 nm excimer laser radiation, in doses of 0.5-3 MJ.m -2 . The action of the radiation on chromatin was monitored by chromatin intrinsic fluorescence and fluorescence lifetimes (of bound ethidium bromide to chromatin) and by analysing fluorescence resonance energy transfer between dansyl chloride and acridine orange coupled to chromatin. For the mentioned doses of UV excimer laser radiation, the action on chromatin was more intense than in the case of fast neutrons. The same types of damage are produced by the two radiations: acidic and basic destruction of chromatin protein structure, DNA strand breaking and the increase of the distance between DNA and proteins in chromatin. (author)

  13. Laser light scattering in Brownian medium

    International Nuclear Information System (INIS)

    Suwono; Santoso, Budi; Baiquni, A.

    1983-01-01

    The principle of laser light scattering in Brownian medium and photon correlation spectroscopy are described in detail. Their application to the study of the behaviour of a polystyrene latex solution are discussed. The auto-correlation function of light scattered by the polystyrene latex solution in various angle, various temperature and in various sample times, have been measured. Information on the translation diffusion coefficient and size on the particle can be obtained from the auto-correlation function. Good agreement between the available data and experiment is shown. (author)

  14. Comparison of efficacy, safety, and predictability of laser in situ keratomileusis using two laser suites

    Directory of Open Access Journals (Sweden)

    Meidani A

    2016-08-01

    Full Text Available Alexandra Meidani,1–3 Chara Tzavara3 1Hypervision Laser Centre, 2Eye Day Clinic, 3Department of Hygiene, University of Athens Medical School, Centre for Health Services Research, Epidemiology and Medical Statistics, Athens, Greece Purpose: The main aim of this study was to compare the efficacy, safety, and predictability of femtosecond laser-assisted in situ keratomileusis performed by two different laser suites in the treatment of myopia for up to 6 months.Methods: In this two-site retrospective nonrandomized study, myopic eyes that underwent laser-assisted in situ keratomileusis using IntraLase FS 60 kHz formed group 1 and those using WaveLight FS200 femtosecond laser system formed group 2. Ablation was performed with Visx Star S4 IR and WaveLight EX500 Excimer lasers, respectively, in groups 1 and 2. Both groups were well matched for age, sex, and mean level of preoperative refractive spherical equivalent (MRSE. Uncorrected distance visual acuity, corrected distance visual acuity, and MRSE were evaluated preoperatively and at 1 week, 1 month, and 6 months after treatment.Results: Fifty-six eyes of 28 patients were included in the study. At 6-month follow-up postop, 78.6% of eyes in group 1 and 92.8% of eyes in group 2 achieved an uncorrected distance visual acuity of 20/20 or better (P=0.252. 35.7% and 50% in group 1 and group 2, respectively, gained one line (P=0.179. No eye lost lines of corrected distance visual acuity. Twenty-five eyes in group 1 (92.7% and 27 eyes in group 2 (96.3% had MRSE within ±0.5 D in the 6-month follow-up (P>0.999. The mean efficacy index at 6 months was similar in group 1 and group 2 (mean 1.10±0.12 [standard deviation] vs 1.10±0.1 (P=0.799. The mean safety index was similar in group 1 and group 2 (mean 1.10±0.10 [standard deviation] vs 1.10±0.09 (P=0.407.Conclusion: The outcomes were excellent between the two laser suites. There were no significant differences at 6-month follow-up postop between the two

  15. Self-sustaining nuclear pumped laser-fusion reactor experiment

    International Nuclear Information System (INIS)

    Boody, F.P.; Choi, C.K.; Miley, G.H.

    1977-01-01

    The features of a neutron feedback nuclear pumped (NFNP) laser-fusion reactor equipment were studied with the intention of establishing the feasibility of the concept. The NFNP laser-fusion concept is compared schematically to electrically pumped laser fusion. The study showed that, once a method of energy storage has been demonstrated, a self-sustaining fusion-fission hybrid reactor with a ''blanket multiplication'' of two would be feasible using nuclear pumped Xe F* excimer lasers having efficiencies of 1 to 2 percent and D-D-T pellets with gains of 50 to 100

  16. The role of lasers and intense pulsed light technology in dermatology

    Science.gov (United States)

    Husain, Zain; Alster, Tina S

    2016-01-01

    The role of light-based technologies in dermatology has expanded dramatically in recent years. Lasers and intense pulsed light have been used to safely and effectively treat a diverse array of cutaneous conditions, including vascular and pigmented lesions, tattoos, scars, and undesired hair, while also providing extensive therapeutic options for cosmetic rejuvenation and other dermatologic conditions. Dermatologic laser procedures are becoming increasingly popular worldwide, and demand for them has fueled new innovations and clinical applications. These systems continue to evolve and provide enhanced therapeutic outcomes with improved safety profiles. This review highlights the important roles and varied clinical applications that lasers and intense pulsed light play in the dermatologic practice. PMID:26893574

  17. Investigation of saturation effects in ceramic phosphors for laser lighting

    DEFF Research Database (Denmark)

    Krasnoshchoka, Anastasiia; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    We report observation of saturation effects in a Ce:LuAG and Eu-doped nitride ceramic phosphor for conversion of blue laser light for white light generation. The luminous flux from the phosphors material increases linearly with the input power until saturation effects limit the conversion....... It is shown, that the temperature of the phosphor layer influences the saturation power level and the conversion efficiency. It is also shown that the correlated color temperature (CCT), phosphor conversion efficiency and color rendering index (CRI) are dependent both on incident power and spot size diameter...... of the illumination. A phosphor conversion efficiency up to 140.8 lm/W with CRI of 89.4 was achieved. The saturation in a ceramic phosphor, when illuminated by high intensity laser diodes, is estimated to play the main role in limiting the available luminance from laser based lighting systems....

  18. 准分子激光角膜表层切削术后的止痛措施%Pain control after excimer laser corneal surface ablation

    Institute of Scientific and Technical Information of China (English)

    曾原; 黄一飞; 高建华

    2014-01-01

    准分子激光角膜表层切削术因降低角膜膨隆的风险和避免准分子激光原位角膜磨镶术( LASIK)角膜瓣相关的并发症而受到青睐。但术后严重疼痛不适为表层切削的主要缺陷,因此表层切削术后疼痛不适的控制显得尤其重要。我们总结了表层切削术后疼痛的机制以及降低术后疼痛的措施的进展。%By reshaping the cornea without the creation of a stromal flap, excimer laser corneal surface ablation eliminates flap-related complications and avoids the risk of ectasia that may occur after laser assisted in situ keratomileusis ( LASIK ) . Post-operative pain is one of the most significant disadvantages of surface ablation and thus the management of pain and discomfort following surface ablation is of great importance. We summarize mechanism of corneal pain and current approaches to pain management after surface ablation.

  19. Spectrum of reflected light by self-focusing of light in a laser plasma

    International Nuclear Information System (INIS)

    Gorbunov, L.M.

    1983-01-01

    The spectrum of the radiation reflected by a laser-produced plasma is considered. In this situation, self-focusing occurs and a region of low density (caviton) is formed. It is shown that the process leads to a considerable broadening of the spectrum on the ''red'' side, and to the appearance of a line structure in the spectrum. The results can explain data for the reflected light spectrum [L. M. Gorbunov et al., FIAN Preprint No. 126 (1979)] as being due to the nonstationary self-focusing of light in a laser-produced plasma that has recently been observed [V. L. Artsimovich et al., FIAN Preprint No. 252 (1981); Sov. Phys. Doklady 27, 618 (1982)

  20. The laser: a concentrate of light. From the creation of a beam to its applications

    International Nuclear Information System (INIS)

    2005-04-01

    The first lasers were developed in the 1960's. The name LASER is an acronym for 'Light Amplification by the Stimulated Emission of Radiation'. The almost magical properties of laser light soon led to their use in a variety of applications. We use lasers every day in our CD players and in the bar-code readers used in supermarkets. Laser light shows create beautiful patterns of light in the air. Lasers are also precision workers in industry. They are used to cut, weld and drill materials. They are used in medicine to repair or burn away diseased tissue without harming healthy tissue nearby. Straight and narrow laser beams are also used to align roads and tunnels. But why is it that lasers can do all these things while ordinary light from the Sun or from a light bulb cannot? 'Lasers are everywhere - in medicine, in industry, and at the heart of our daily lives'. CEA has worked on all types of lasers for many years. CEA researchers use them in their work in all the traditional ways (alignment, drilling, welding, cutting, etc.), but they also develop new types of lasers for specific applications. They use very high power lasers to study the interaction between high energies and matter. Lasers are essential tools in many applications, but we must never forget the risks that are associated with them. The CEA is studying the effects of lasers on the body. There is still much research to be done in the field of laser technology. We expect more and more applications in the next few years. (authors)

  1. Blue laser diode (LD) and light emitting diode (LED) applications

    International Nuclear Information System (INIS)

    Bergh, Arpad A.

    2004-01-01

    The family of blue LEDs, edge emitting and surface emitting lasers, enable a number of applications. Blue lasers are used in digital applications such as optical storage in high density DVDs. The resolution of the spot size and hence the storage density is diffraction limited and is inversely proportional to the square of the wavelength of the laser. Other applications include printing, optical scanners, and high-resolution photo-lithography. As light emitters, blue LEDs are used for signaling and in direct view large area emissive displays. They are also making inroads into signage and LCD back-lighting, mobile platforms, and decorative accent lighting in curtains, furniture, etc. Blue LEDs produce white light either with phosphor wavelength converters or in combination with red and green LEDs. The full potential of LED light sources will require three devices to enable complete control over color and intensity. Sensing and medical/bio applications have a major impact on home security, on monitoring the environment, and on health care. New emerging diagnostic and therapeutic applications will improve the quality and reduce the cost of health care. (copyright 2004 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. Blue laser diode (LD) and light emitting diode (LED) applications

    Energy Technology Data Exchange (ETDEWEB)

    Bergh, Arpad A [Optoelectronics Industry Development Association (OIDA), 1133 Connecticut Avenue, NW, Suite 600, Washington, DC 20036-4329 (United States)

    2004-09-01

    The family of blue LEDs, edge emitting and surface emitting lasers, enable a number of applications. Blue lasers are used in digital applications such as optical storage in high density DVDs. The resolution of the spot size and hence the storage density is diffraction limited and is inversely proportional to the square of the wavelength of the laser. Other applications include printing, optical scanners, and high-resolution photo-lithography. As light emitters, blue LEDs are used for signaling and in direct view large area emissive displays. They are also making inroads into signage and LCD back-lighting, mobile platforms, and decorative accent lighting in curtains, furniture, etc. Blue LEDs produce white light either with phosphor wavelength converters or in combination with red and green LEDs. The full potential of LED light sources will require three devices to enable complete control over color and intensity. Sensing and medical/bio applications have a major impact on home security, on monitoring the environment, and on health care. New emerging diagnostic and therapeutic applications will improve the quality and reduce the cost of health care. (copyright 2004 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. The spatial thickness distribution of metal films produced by large area pulsed laser deposition

    DEFF Research Database (Denmark)

    Pryds, Nini; Schou, Jørgen; Linderoth, Søren

    2007-01-01

    Thin films of metals have been deposited in the large-area Pulsed Laser Deposition (PLD) Facility at Riso National Laboratory. Thin films of Ag and Ni were deposited with laser pulses from an excimer laser at 248 nm with a rectangular beam spot at a fluence of 10 J/cm(2) on glass substrates of 127...

  4. FEM numerical analysis of excimer laser induced modification in alternating multi-layers of amorphous and nano-crystalline silicon films

    International Nuclear Information System (INIS)

    Conde, J.C.; Martín, E.; Stefanov, S.; Alpuim, P.; Chiussi, S.

    2012-01-01

    Highlights: ► nc-Si:H is a material with growing importance for a large-area of nano-electronic, photovoltaic or biomedical devices. ► UV-ELA technique causes a rapid heating that provokes the H 2 desorption from the Si surface and bulk material. ► Next, diffusion of P doped nc-Si films and eventually, for high energy densities would be possible to reach the melting point. ► These multilayer structures consisting of thin alternating a-Si:H(10 nm) and n-doped nc-Si:H(60 nm) films deposited on SiO 2 . ► To optimize parameters involved in this processing, FEM numerical analysis of multilayer structures have been performed. ► The numerical results are compared with exhaustive characterization of the experimental results. - Abstract: UV excimer laser annealing (UV-ELA) is an alternative annealing process that, during the last few years, has gained enormous importance for the CMOS nano-electronic technologies, with the ability to provide films and alloys with electrical and optical properties to fit the desired device performance. The UV-ELA of amorphous (a-) and/or doped nano-crystalline (nc-) silicon films is based on the rapid (nanoseconds) formation of temperature profiles caused by laser radiation that is absorbed in the material and lead to crystallisation, diffusion in solid or even in liquid phase. To achieve the desired temperature profiles and to optimize the parameters involved in the processing of hydrogenated nanocrystalline silicon (nc-Si:H) films with the UV-ELA, a numerical analysis by finite element method (FEM) of a multilayer structure has been performed. The multilayer structures, consisting of thin alternating a-Si:H(10 nm) and n-doped nc-Si:H(60 nm) layers, deposited on a glass substrate, has also been experimentally analyzed. Temperature profiles caused by 193 nm radiation with 25 ns pulse length and energy densities ranging from 50 mJ/cm 2 to 400 mJ/cm 2 have been calculated. Numerical results allowed us to estimate the dehydrogenation

  5. Carbon nanotube formation by laser direct writing

    International Nuclear Information System (INIS)

    Wu, Y.-T.; Su, H.-C.; Tsai, C.-M.; Liu, K.-L.; Chen, G.-D.; Huang, R.-H.; Yew, T.-R.

    2008-01-01

    This letter presents carbon nanotube (CNT) formation by laser direct writing using 248 nm KrF excimer pulsed laser in air at room temperature, which was applied to irradiate amorphous carbon (a-C) assisted by Ni catalysts underneath for the transformation of carbon species into CNTs. The CNTs were synthesized under appropriate combination of laser energy density and a-C thickness. The growth mechanism and key parameters to determine the success of CNT formation were also discussed. The demonstration of the CNT growth by laser direct writing in air at room temperature opens an opportunity of in-position CNT formation at low temperatures

  6. Basic study of charring detection at the laser catheter-tip using back scattering light measurement during therapeutic laser irradiation in blood.

    Science.gov (United States)

    Takahashi, Mei; Ito, Arisa; Kajihara, Takuro; Matsuo, Hiroki; Arai, Tsunenori

    2010-01-01

    The purpose of this study is to investigate transient process of the charring at the laser catheter-tip in blood during therapeutic laser irradiation by the back scattering light measurement to detect precursor state of the charring. We took account of using photodynamic therapy for arrhythmia in blood through the laser catheter. We observed the influence of the red laser irradiation (λ=663 nm) upon the shape of red blood cells (RBCs). The RBCs aggregation, round formation, and hemolysis were took place sequentially before charring. With a model blood sandwiched between glass plates simulated as a catheter-tip boundary, we measured diffuse-reflected-light power and transmitted-light power simultaneously and continuously by a microscopic optics during the laser irradiation. We found that measured light power changes were originated with RBCs shape change induced by temperature rise due to the laser irradiation. A gentle peak following a slow descending was observed in the diffuse-reflected-light power history. This history might indicate the precursor state of the charring, in which the hemolysis might be considered to advance rapidly. We think that the measurement of diffuse-reflected-light power history might be able to detect precursor state of charring at the catheter-tip in blood.

  7. Laterally injected light-emitting diode and laser diode

    Science.gov (United States)

    Miller, Mary A.; Crawford, Mary H.; Allerman, Andrew A.

    2015-06-16

    A p-type superlattice is used to laterally inject holes into an III-nitride multiple quantum well active layer, enabling efficient light extraction from the active area. Laterally-injected light-emitting diodes and laser diodes can enable brighter, more efficient devices that impact a wide range of wavelengths and applications. For UV wavelengths, applications include fluorescence-based biological sensing, epoxy curing, and water purification. For visible devices, applications include solid state lighting and projection systems.

  8. Phosphorous Diffuser Diverged Blue Laser Diode for Indoor Lighting and Communication

    KAUST Repository

    Chi, Yu-Chieh; Hsieh, Dan-Hua; Lin, Chung-Yu; Chen, Hsiang-Yu; Huang, Chia-Yen; He, Jr-Hau; Ooi, Boon S.; DenBaars, Steven P.; Nakamura, Shuji; Kuo, Hao-Chung; Lin, Gong-Ru

    2015-01-01

    An advanced light-fidelity (Li-Fi) system based on the blue Gallium nitride (GaN) laser diode (LD) with a compact white-light phosphorous diffuser is demonstrated for fusing the indoor white-lighting and visible light communication (VLC

  9. Singly-resonant sum frequency generation of visible light in a semiconductor disk laser

    DEFF Research Database (Denmark)

    Andersen, Martin Thalbitzer; Schlosser, P.J.; Hastie, J.E.

    2009-01-01

    In this paper a generic approach for visible light generation is presented. It is based on sum frequency generation between a semiconductor disk laser and a solid-state laser, where the frequency mixing is achieved within the cavity of the semiconductor disk laser using a singlepass of the solid......-state laser light. This exploits the good beam quality and high intra-cavity power present in the semiconductor disk laser to achieve high conversion efficiency. Combining sum frequency mixing and semiconductor disk lasers in this manner allows in principle for generation of any wavelength within the visible...

  10. Kinetic studies following state-selective laser excitation

    International Nuclear Information System (INIS)

    Keto, J.W.

    1991-01-01

    During the past year, we have made measurements of state-to-state energy transfer cross sections and radiative lifetimes for Xe*(6p,6p',7p) and Kr*(5p) states in xenon and krypton buffer gases. These results are relevant to kinetic models of both excimer lasers and the infrared xenon laser; and they are a significant improvement in the precision of the known radiative lifetimes. 3 refs., 2 figs., 2 tabs

  11. Shaping laser accelerated ions for future applications – The LIGHT collaboration

    International Nuclear Information System (INIS)

    Busold, S.; Almomani, A.; Bagnoud, V.; Barth, W.; Bedacht, S.; Blažević, A.; Boine-Frankenheim, O.

    2014-01-01

    The generation of intense ion beams from high-intensity laser-generated plasmas has been the focus of research for the last decade. In the LIGHT collaboration the expertise of heavy ion accelerator scientists and laser and plasma physicists has been combined to investigate the prospect of merging these ion beams with conventional accelerator technology and exploring the possibilities of future applications. We report about the goals and first results of the LIGHT collaboration to generate, handle and transport laser driven ion beams. This effort constitutes an important step in research for next generation accelerator technologies

  12. Shaping laser accelerated ions for future applications – The LIGHT collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Busold, S., E-mail: s.busold@gsi.de [Institut für Kernphysik, Technische Universität Darmstadt, Schloßgartenstraße 9, D-64289 Darmstadt (Germany); Almomani, A. [Institut für angewandte Physik, Johann-Wolfgang-Goethe-Universität Frankfurt, Max von Laue Straße 1, D-60438 Frankfurt (Germany); Bagnoud, V. [GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, D-64291 Darmstadt (Germany); Helmholtz Institut Jena, Fröbelstieg 3, D-07734 Jena (Germany); Barth, W. [GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, D-64291 Darmstadt (Germany); Bedacht, S. [Institut für Kernphysik, Technische Universität Darmstadt, Schloßgartenstraße 9, D-64289 Darmstadt (Germany); Blažević, A. [GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, D-64291 Darmstadt (Germany); Helmholtz Institut Jena, Fröbelstieg 3, D-07734 Jena (Germany); Boine-Frankenheim, O. [GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, D-64291 Darmstadt (Germany); Institut für Theorie Elektromagnetischer Felder, Technische Universität Darmstadt, Schloßgartenstraße 8, D-64289 Darmstadt (Germany); and others

    2014-03-11

    The generation of intense ion beams from high-intensity laser-generated plasmas has been the focus of research for the last decade. In the LIGHT collaboration the expertise of heavy ion accelerator scientists and laser and plasma physicists has been combined to investigate the prospect of merging these ion beams with conventional accelerator technology and exploring the possibilities of future applications. We report about the goals and first results of the LIGHT collaboration to generate, handle and transport laser driven ion beams. This effort constitutes an important step in research for next generation accelerator technologies.

  13. Lasers and intense pulsed light (IPL) association with cancerous lesions.

    Science.gov (United States)

    Ash, Caerwyn; Town, Godfrey; Whittall, Rebecca; Tooze, Louise; Phillips, Jaymie

    2017-11-01

    The development and use of light and lasers for medical and cosmetic procedures has increased exponentially over the past decade. This review article focuses on the incidence of reported cases of skin cancer post laser or IPL treatment. The existing evidence base of over 25 years of laser and IPL use to date has not raised any concerns regarding its long-term safety with only a few anecdotal cases of melanoma post treatment over two decades of use; therefore, there is no evidence to suggest that there is a credible cancer risk. Although laser and IPL technology has not been known to cause skin cancer, this does not mean that laser and IPL therapies are without long-term risks. Light therapies and lasers to treat existing lesions and CO 2 laser resurfacing can be a preventative measure against BCC and SCC tumour formation by removing photo-damaged keratinocytes and encouraged re-epithelisation from stem cells located deeper in the epidermis. A review of the relevant literature has been performed to address the issue of long-term IPL safety, focussing on DNA damage, oxidative stress induction and the impact of adverse events.

  14. Amplification of picosecond pulse by electron-beam pumped KrF laser amplifiers. Denshi beam reiki KrF laser zofukuki ni yoru piko byo pulse no zofuku

    Energy Technology Data Exchange (ETDEWEB)

    Okuda, I.; Tomie, T.; Owadano, Y.; Yano, M. (Electrotechnical Laboratory, Tsukuba (Japan))

    1991-08-20

    Experiments on the amplification of a picosecond pulse by electron-beam pumped KrF laser amplifiers were carried out for the purpose of its application to the field such as excitation light source for soft X-ray laser which requires large energy besides peak power. The picosecond pulse was amplified by a discharge pumped KrF amplifier and two electron-beam pumped KrF amplifiers(at the middle stage and the final stage). The energy of 4J, which was the largest energy for short pulse excimer laser so far, was obtained by these devices. About 90% of the window area of the final amplifier with 29cm diameter was filled by the input beam, and energy density of the picosecond beam reached 3.9 times saturation energy density. Measured energy of amplified spontaneous emission(ASE) showed good agreement with the theoretically estimated value. Most of ASE was derived from the discharge pumped laser as the first amplifier. As for the focused power density, the power density ratio of the picosecond pulse to ASE was estimated to be as large as 10{sup 5}. 11 refs., 4 figs.

  15. Laser- and UV-assisted modification of polystyrene surfaces for control of protein adsorption and cell adhesion

    International Nuclear Information System (INIS)

    Pfleging, Wilhelm; Torge, Maika; Bruns, Michael; Trouillet, Vanessa; Welle, Alexander; Wilson, Sandra

    2009-01-01

    An appropriate choice of laser and process parameters enables new approaches for the fabrication of polymeric lab-on-chip devices with integrated functionalities. We will present our current research results in laser-assisted modification of polystyrene (PS) with respect to the fabrication of polymer devices for cell culture applications. For this purpose laser micro-patterning of PS and subsequent surface functionalization was investigated as function of laser and process parameters. A high power ArF-excimer laser radiation source with a pulse length of 19 ns as well as a high repetition ArF-excimer laser source with a pulse length of 5 ns were used in order to study the influence of laser pulse length on laser-induced surface oxidation. The change in surface chemistry was characterized by X-ray photoelectron spectroscopy and contact angle measurements. The difference between laser-assisted modification versus UV-lamp assisted modification was investigated. A photolytic activation of specific areas of the polymer surface and subsequent oxidization in oxygen or ambient air leads to a chemically modified polymer surface bearing carboxylic acid groups well-suited for controlled competitive protein adsorption or protein immobilization. Finally, distinct areas for cell growth and adhesion are obtained

  16. Tritium recovery from co-deposited layers using 193-nm laser

    Science.gov (United States)

    Shu, W. M.; Kawakubo, Y.; Nishi, M. F.

    Recovery of tritium from co-deposited layers formed in deuterium-tritium plasma operations of the TFTR (Tokamak Fusion Test Reactor) was investigated by the use of an ArF excimer laser operating at the wavelength of 193 nm. At the laser energy density of 0.1 J/cm2, a transient spike of the tritium-release rate was observed at initial irradiation. Hydrogen isotopes were released in the form of hydrogen-isotope molecules during the laser irradiation in vacuum, suggesting that tritium can be recovered readily from the released gases. In a second experiment, hydrogen (tritium) recovery from the co-deposited layers on JT-60 tiles that had experienced hydrogen-plasma operations was investigated by laser ablation with a focused beam of the excimer laser. The removal rate of the co-deposited layers was quite low when the laser energy density was smaller than the ablation threshold (1.0 J/cm2), but reached 1.1 μm/pulse at the laser energy density of 7.6 J/cm2. The effective absorption coefficient in the co-deposited layers at the laser wavelength was determined to be 1.9 μm-1. The temperature of the surface during the irradiation at the laser energy density of 0.5 J/cm2 was measured on the basis of Planck's law of radiation, and the maximum temperature during the irradiation decreased from 3570 K at the initial irradiation to 2550 K at the 1000th pulse of the irradiation.

  17. Growth and development of Arabidopsis thaliana under single-wavelength red and blue laser light

    KAUST Repository

    Ooi, Amanda Siok Lee

    2016-09-23

    Indoor horticulture offers a sensible solution for sustainable food production and is becoming increasingly widespread. However, it incurs high energy and cost due to the use of artificial lighting such as high-pressure sodium lamps, fluorescent light or increasingly, the light-emitting diodes (LEDs). The energy efficiency and light quality of currently available horticultural lighting is suboptimal, and therefore less than ideal for sustainable and cost-effective large-scale plant production. Here, we demonstrate the use of high-powered single-wavelength lasers for indoor horticulture. They are highly energy-efficient and can be remotely guided to the site of plant growth, thus reducing on-site heat accumulation. Furthermore, laser beams can be tailored to match the absorption profiles of different plant species. We have developed a prototype laser growth chamber and demonstrate that plants grown under laser illumination can complete a full growth cycle from seed to seed with phenotypes resembling those of plants grown under LEDs reported previously. Importantly, the plants have lower expression of proteins diagnostic for light and radiation stress. The phenotypical, biochemical and proteome data show that the single-wavelength laser light is suitable for plant growth and therefore, potentially able to unlock the advantages of this next generation lighting technology for highly energy-efficient horticulture.

  18. Characterization of superconducting thin films deposited by laser ablation. Caracterisation de films minces supraconducteurs deposes par ablation laser

    Energy Technology Data Exchange (ETDEWEB)

    Sentis, M; Delaporte, P [I.M.F.M., 13 - Marseille (FR); Gerri, M; Marine, W [Aix-Marseille-2 Univ., 13-Marseille (FR). Centre Universitaire de Luminy

    1991-05-01

    Thin films of YBa{sub 2}Cu{sub 3}O{sub 7} are deposited by laser ablation on MgO and YSZ substrates. Deposits by infrared (I.R.) Nd: YAG are non stoechiometric. The films having the best superconductor qualities are deposited by ablation with an excimer U.V. laser ({lambda} = 308 nm). These films are epitaxiated with the c axis perpendicular to the substrate. The film quality depends on the substrate temperature, oxygen pressure and cooling speed.

  19. Laser coupling to reduced-scale targets at Nif Early Light

    Energy Technology Data Exchange (ETDEWEB)

    Hinkel, D.E.; Schneider, M.B.; Young, B.K.; Holder, J.P.; Langdon, A.B.; Bonanno, G.; Bower, D.E.; Bruns, H.C.; Campbell, K.M.; Celeste, J.R.; Compton, S.; Costa, R.L.; Dewald, E.L.; Dixit, S.N.; Eckart, M.J.; Eder, D.C.; Edwards, M.J.; Ellis, A.D.; Emig, J.A.; Froula, D.H.; Glenzer, S.H.; Hargrove, D.; Haynam, C.A.; Heeter, R.F.; Henesian, M.A.; Holtmeier, G.; James, D.L.; Jancaitis, K.S.; Kalantar, K.H.; Kamperschroer, J.H.; Kauffman, R.L.; Kimbrough, J.; Kirkwood, R.K.; Koniges, A.E.; Landen, O.L.; Landon, M.; Lee, F.D.; MacGowan, B.J.; Mackinnon, A.J.; Manes, K.R.; Marshall, C.; May, M.J.; McDonald, J.W.; Menapace, J.; Moses, S.E.I.; Munro, D.H.; Murray, J.R.; Niemann, C.; Power, G.D.; Rekow, V.; Ruppe, J.A.; Schein, J.; Shepherd, R.; Singh, M.S.; Springer, P.T.; Still, C.H.; Suter, L.J.; Tietbohl, G.L.; Turner, R.E.; VanWonterghem, B.M.; Wallace, R.J.; Warrick, A.; Weber, F.; Wegner, P.J.; Williams, E.A.; Young, P.E. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Baldis, H.A. [California at Davis Univ., CA (United States); Pellinen, D.; Watts, P. [Bechtel Nevada Corporation, Livermore, CA (United States)

    2006-06-15

    Deposition of maximum laser energy into a small, high-Z enclosure in a short laser pulse creates a hot environment. Such targets were recently included in an experimental campaign using the first four of the 192 beams of the National Ignition Facility (NIF) under construction at the University of California Lawrence Livermore National Laboratory. These targets demonstrate good laser coupling, reaching a radiation temperature of 340 eV. In addition, the Raman backscatter spectrum contains features consistent with Brillouin backscatter of Raman forward scatter. Also, NIF Early Light diagnostics indicate that 20% of the direct backscatter from these reduced-scale targets is in the polarization orthogonal to that of the incident light. (authors)

  20. Time-resolved diagnostics of excimer laser-generated ablation plasmas used for pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Geohegan, D.B.

    1994-09-01

    Characteristics of laser plasmas used for pulsed laser deposition (PLD) of thin films are examined with four in situ diagnostic techniques: Optical emission spectroscopy, optical absorption spectroscopy, ion probe studies, and gated ICCD (intensified charge-coupled-device array) fast photography. These four techniques are complementary and permit simultaneous views of the transport of ions, excited states, ground state neutrals and ions, and hot particulates following KrF laser ablation of YBCO, BN, graphite and Si in vacuum and background gases. The implementation and advantages of the four techniques are first described in order to introduce the key features of laser plasmas for pulsed laser deposition. Aspects of the interaction of the ablation plume with background gases (i.e., thermalization, attenuation, shock formation) and the collision of the plasma plume with the substrate heater are then summarized. The techniques of fast ICCD photography and gated photon counting are then applied to investigate the temperature, velocity, and spatial distribution of hot particles generated during KrF ablation of YBCO, BN, Si and graphite. Finally, key features of fast imaging of the laser ablation of graphite into high pressure rare gases are presented in order to elucidate internal reflected shocks within the plume, redeposition of material on a surface, and formation of hot nanoparticles within the plume.

  1. Time-resolved diagnostics of excimer laser-generated ablation plasmas used for pulsed laser deposition

    International Nuclear Information System (INIS)

    Geohegan, D.B.

    1994-01-01

    Characteristics of laser plasmas used for pulsed laser deposition (PLD) of thin films are examined with four in situ diagnostic techniques: Optical emission spectroscopy, optical absorption spectroscopy, ion probe studies, and gated ICCD (intensified charge-coupled-device array) fast photography. These four techniques are complementary and permit simultaneous views of the transport of ions, excited states, ground state neutrals and ions, and hot particulates following KrF laser ablation of YBCO, BN, graphite and Si in vacuum and background gases. The implementation and advantages of the four techniques are first described in order to introduce the key features of laser plasmas for pulsed laser deposition. Aspects of the interaction of the ablation plume with background gases (i.e., thermalization, attenuation, shock formation) and the collision of the plasma plume with the substrate heater are then summarized. The techniques of fast ICCD photography and gated photon counting are then applied to investigate the temperature, velocity, and spatial distribution of hot particles generated during KrF ablation of YBCO, BN, Si and graphite. Finally, key features of fast imaging of the laser ablation of graphite into high pressure rare gases are presented in order to elucidate internal reflected shocks within the plume, redeposition of material on a surface, and formation of hot nanoparticles within the plume

  2. Design of fiber optic probes for laser light scattering

    Science.gov (United States)

    Dhadwal, Harbans S.; Chu, Benjamin

    1989-01-01

    A quantitative analysis is presented of the role of optical fibers in laser light scattering. Design of a general fiber optic/microlens probe by means of ray tracing is described. Several different geometries employing an optical fiber of the type used in lightwave communications and a graded index microlens are considered. Experimental results using a nonimaging fiber optic detector probe show that due to geometrical limitations of single mode fibers, a probe using a multimode optical fiber has better performance, for both static and dynamic measurements of the scattered light intensity, compared with a probe using a single mode fiber. Fiber optic detector probes are shown to be more efficient at data collection when compared with conventional approaches to measurements of the scattered laser light. Integration of fiber optic detector probes into a fiber optic spectrometer offers considerable miniaturization of conventional light scattering spectrometers, which can be made arbitrarily small. In addition static and dynamic measurements of scattered light can be made within the scattering cell and consequently very close to the scattering center.

  3. Discharge-current characteristics in UV-preionized Kr/He, F2/He gas-mixtures and KrF excimer laser gas. Shigaisen yobi denri Kr/He, F2/He kongo kitai hoden oyobi KrF laser reiki hoden no denryu tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, N.; Kawakami, H.; Yukimura, K. (Doshisha University, Kyoto (Japan))

    1992-08-15

    In order to study effects of Kr and F2 on discharge characteristics of KrF excimer laser gas, gap phenomena in Kr/He and F2/He gas-mixtures were observed and discharge current (I[sub d]) was measured. In the range where Kr concentration was over 10% in Kr/He gas, in which production of filamentation as well as glow discharge started, discontinuous change in I[sub d] in the second or third half cycle was observed. According to the results of experiments and model analyses, it was considered that the discontinuity of the current showed the transition point to filamentation. When F2 concentration was in the range between 0.1 and 0.3% in F2/He mixture gas, filamentation and arc with glow were observed. Sine-waveform I[sub d] ended in the first half cycle, and began to flow again after cessation or had almost constant current due to arc and others. When F2 was over 0.4%, only are discharge was observed. It was thus found that F2 has a large effect on discharge characteristics of KrF laser gas. 18 refs., 9 figs.

  4. Preliminary design and estimate of capital and operating costs for a production scale application of laser decontamination technology

    International Nuclear Information System (INIS)

    Pang, Ho-ming; Edelson, M.C.

    1994-01-01

    The application of laser ablation technology to the decontamination of radioactive metals, particularly the surfaces of equipment, is discussed. Included is information related to the design, capital and operating costs, and effectiveness of laser ablation technology, based on commercial excimer and Nd:YAG lasers, for the decontamination of production scale equipment

  5. Choice of the laser wavelength for a herpetic keratitis treatment

    Science.gov (United States)

    Razhev, Alexander M.; Bagayev, Sergei N.; Chernikh, Valery V.; Kargapoltsev, Evgeny S.; Trunov, Alexander; Zhupikov, Andrey A.

    2002-06-01

    For the first time the effect of the UV laser radiation to human eye cornea with herpetic keratitis was experimentally investigated. In experiments the UV radiation of ArF (193 nm), KrCl (223 nm), KrF (248 nm) excimer lasers were used. Optimal laser radiation parameters for the treatment of the herpetic keratitis were determined. The immuno-biochemical investigations were carried out and the results of clinical trials are presented. The maximum ablation rate was obtained for the 248 nm radiation wavelength. The process of healing was successful but in some cases the haze on the surface of the cornea was observed. When used the 193 nm radiation wavelength the corneal surface was clear without any hazes but the epithelization process was slower than for 248 nm wavelength and in some cases the relapse was occurred. The best results for herpetic keratitis treatment have been achieved by utilizing the 223 nm radiation wavelength of the KrCl excimer laser. The use of the 223 nm radiation wavelength allows treating the herpetic keratitis with low traumatic process of ablation and provides high quality of corneal surface.

  6. Exotic behavior of molecules in intense laser light fields. New research directions

    Energy Technology Data Exchange (ETDEWEB)

    Yamanouchi, Kaoru [Tokyo Univ., Department of Chemistry, Tokyo (Japan)

    2002-08-01

    The recent investigation of the dynamical behavior of molecules and clusters in intense laser fields has afforded us invaluable opportunities to understand fundamentals of the interaction between molecular species and light fields as well as to manipulate molecules and their dynamical pathways by taking advantage of characteristics of coherent ultrashort laser light fields. In the present report, new directions of this rapidly growing interdisciplinary research fields called molecular science in intense laser fields are discussed by referring to our recent studies. (author)

  7. LIGHT - from laser ion acceleration to future applications

    Science.gov (United States)

    Roth, Markus; Light Collaboration

    2013-10-01

    Creation of high intensity multi-MeV ion bunches by high power lasers became a reliable tool during the last 15 years. The laser plasma source provides for TV/m accelerating field gradients and initially sub-ps bunch lengths. However, the large envelope divergence and the continuous exponential energy spectrum are substential drawbacks for many possible applications. To face this problem, the LIGHT collaboration was founded (Laser Ion Generation, Handling and Transport). The collaboration consists of several university groups and research centers, namely TU Darmstadt, JWGU Frankfurt, HI Jena, HZDR Dresden and GSI Darmstadt. The central goal is building a test beamline for merging laser ion acceleration with conventional accelerator infrastructure at the GSI facility. In the latest experiments, low divergent proton bunches with a central energy of up to 10 MeV and containing >109 particles could be provided at up to 2.2 m behind the plasma source, using a pulsed solenoid. In a next step, a radiofrequency cavity will be added to the beamline for phase rotation of these bunches, giving access to sub-ns bunch lengths and reaching highest intensities. An overview of the LIGHT objectives and the recent experimental results will be given. This work was supported by HIC4FAIR.

  8. Growth experiment in lettuce [Lactuca sativa] using laser light

    International Nuclear Information System (INIS)

    Mori, Y.; Takatsuji, M.

    2001-01-01

    Photosynthetic rate, relative growth rate and vitamin C contents were measured in lettuce cultivated under red and blue lasers and the results were compared with those cultivated under light emitting diodes (LED). It was found that lettuce grew fairly healthily under red laser diode (650 nm) and blue laser (442 nm) with R/B ratio 10. However, both photosynthetic rate and growth rate rather diminished compared with LED cases. As for vitamin C contents, the result was about the same as LED cases

  9. Silicon light-emitting diodes and lasers photon breeding devices using dressed photons

    CERN Document Server

    Ohtsu, Motoichi

    2016-01-01

    This book focuses on a novel phenomenon named photon breeding. It is applied to realizing light-emitting diodes and lasers made of indirect-transition-type silicon bulk crystals in which the light-emission principle is based on dressed photons. After presenting physical pictures of dressed photons and dressed-photon phonons, the principle of light emission by using dressed-photon phonons is reviewed. A novel phenomenon named photon breeding is also reviewed. Next, the fabrication and operation of light emitting diodes and lasers are described The role of coherent phonons in these devices is discussed. Finally, light-emitting diodes using other relevant crystals are described and other relevant devices are also reviewed.

  10. Fabrication of versatile cladding light strippers and fiber end-caps with CO2 laser radiation

    Science.gov (United States)

    Steinke, M.; Theeg, T.; Wysmolek, M.; Ottenhues, C.; Pulzer, T.; Neumann, J.; Kracht, D.

    2018-02-01

    We report on novel fabrication schemes of versatile cladding light strippers and end-caps via CO2 laser radiation. We integrated cladding light strippers in SMA-like connectors for reliable and stable fiber-coupling of high-power laser diodes. Moreover, the application of cladding light strippers in typical fiber geometries for high-power fiber lasers was evaluated. In addition, we also developed processes to fuse end-caps to fiber end faces via CO2 laser radiation and inscribe the fibers with cladding light strippers near the end-cap. Corresponding results indicate the great potential of such devices as a monolithic and low-cost alternative to SMA connectors.

  11. Advanced lasers for fusion

    International Nuclear Information System (INIS)

    Krupke, W.F.; George, E.V.; Haas, R.A.

    1979-01-01

    Laser drive systems' performance requirements for fusion reactors are developed following a review of the principles of inertial confinement fusion and of the technical status of fusion research lasers (Nd:glass; CO 2 , iodine). These requirements are analyzed in the context of energy-storing laser media with respect to laser systems design issues: optical damage and breakdown, medium excitation, parasitics and superfluorescence depumping, energy extraction physics, medium optical quality, and gas flow. Three types of energy-storing laser media of potential utility are identified and singled out for detailed review: (1) Group VI atomic lasers, (2) rare earth solid state hybrid lasers, and (3) rare earth molecular vapor lasers. The use of highly-radiative laser media, particularly the rare-gas monohalide excimers, are discussed in the context of short pulse fusion applications. The concept of backward wave Raman pulse compression is considered as an attractive technique for this purpose. The basic physics and device parameters of these four laser systems are reviewed and conceptual designs for high energy laser systems are presented. Preliminary estimates for systems efficiencies are given. (Auth.)

  12. Laser-assisted immobilization of colloid silver nanoparticles on polyethyleneterephthalate

    Czech Academy of Sciences Publication Activity Database

    Siegel, J.; Lyutakov, O.; Polívková, M.; Staszek, M.; Hubáček, Tomáš; Švorčík, V.

    2017-01-01

    Roč. 420, OCT (2017), s. 661-668 ISSN 0169-4332 R&D Projects: GA MŠk LM2015075 Institutional support: RVO:60077344 Keywords : silver nanoparticles * polyethyleneterephthalate * excimer laser * immobilization Subject RIV: JJ - Other Materials OBOR OECD: Materials engineering Impact factor: 3.387, year: 2016

  13. III-nitride Photonic Integrated Circuit: Multi-section GaN Laser Diodes for Smart Lighting and Visible Light Communication

    KAUST Repository

    Shen, Chao

    2017-01-01

    The past decade witnessed the rapid development of III-nitride light-emitting diodes (LEDs) and laser diodes (LDs), for smart lighting, visible-light communication (VLC), optical storage, and internet-of-things. Recent studies suggested that the Ga

  14. Mid-infrared pulsed laser ablation of the arterial wall. Mechanical origin of "acoustic" wall damage and its effect on wall healing

    NARCIS (Netherlands)

    van Erven, L.; van Leeuwen, T. G.; Post, M. J.; van der Veen, M. J.; Velema, E.; Borst, C.

    1992-01-01

    Pulsed mid-infrared lasers are an alternative to excimer lasers for transluminal angioplasty. The mid-infrared lasers, however, were reported to produce "acoustic" wall damage that might impair the immediate and long-term results. To study the immediate and long-term effects on the arterial wall,

  15. Laser-produced plasma-extreme ultraviolet light source for next generation lithography

    International Nuclear Information System (INIS)

    Nishihara, Katsunobu; Nishimura, Hiroaki; Gamada, Kouhei; Murakami, Masakatsu; Mochizuki, Takayasu; Sasaki, Akira; Sunahara, Atsushi

    2005-01-01

    Extreme ultraviolet (EUV) lithography is the most promising candidate for the next generation lithography for the 45 nm technology node and below. EUV light sources under consideration use 13.5 nm radiations from multicharged xenon, tin and lithium ions, because Mo/Si multiplayer mirrors have high reflectivity at this wavelength. A review of laser-produced plasma (LPP) EUV light sources is presented with a focus on theoretical and experimental studies under the auspices of the Leading Project promoted by MEXT. We discuss three theoretical topics: atomic processes in the LPP-EUV light source, conversion efficiency from laser light to EUV light at 13.5 nm wave-length with 2% bound width, and fast ion spectra. The properties of EUV emission from tin and xenon plasmas are also shown based on experimental results. (author)

  16. Enhanced light scattering in Si nanostructures produced by pulsed laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Sberna, P. M.; Scapellato, G. G.; Boninelli, S.; Miritello, M.; Crupi, I.; Bruno, E.; Privitera, V.; Simone, F.; Mirabella, S. [MATIS IMM-CNR and Dipartimento di Fisica e Astronomia, Università di Catania, via S. Sofia 64, 95123 Catania (Italy); Piluso, N. [IMM-CNR, VIII strada 5, 95121 Catania (Italy)

    2013-11-25

    An innovative method for Si nanostructures (NS) fabrication is proposed, through nanosecond laser irradiation (λ = 532 nm) of thin Si film (120 nm) on quartz. Varying the laser energy fluences (425–1130 mJ/cm{sup 2}) distinct morphologies of Si NS appear, going from interconnected structures to isolated clusters. Film breaking occurs through a laser-induced dewetting process. Raman scattering is enhanced in all the obtained Si NS, with the largest enhancement in interconnected Si structures, pointing out an increased trapping of light due to multiple scattering. The reported method is fast, scalable and cheap, and can be applied for light management in photovoltaics.

  17. Coherent laser phase retrieval in the presence of measurement imperfections and incoherent light

    DEFF Research Database (Denmark)

    Hansen, Anders Kragh

    2017-01-01

    -plane Gerchberg–Saxton algorithm and demonstrate that it is highly successful at extracting the intensity profile and wavefront of the spatially coherent part of the light from various lasers, including tapered laser diodes, at a very high fidelity despite the presence of incoherent light and noise....

  18. Alopecia: a review of laser and light therapies.

    Science.gov (United States)

    Rangwala, Sophia; Rashid, Rashid M

    2012-02-15

    Since the 1980s, laser technology has become increasingly popular to treat a variety of cutaneous conditions. Its successful use as an epilator comes with the rare but interesting side effect of paradoxical hypertrichosis. In this review, we summarize cases describing hair growth after photoepilation, as well as studies testing laser and light sources as treatment for alopecia, particularly androgenetic alopecia and alopecia areata. We also discuss the possible biologic mechanisms by which phototherapy induces hair regeneration.

  19. A method of atmospheric density measurements during Shuttle entry using UV laser Rayleigh scattering

    Science.gov (United States)

    Mckenzie, Robert L.

    1987-01-01

    A detailed study is described of the performance capabilities and the hardware requirements for a method in which ambient density is measured along the Space Shuttle flight path using on-board optical instrumentation. The technique relies on Rayleigh scattering of light from a pulsed, ultraviolet, ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing direct measurements of ambient density with an uncertainty of less than 1 percent and with a spatial resolution of 1 km, over an altitude range from 50 to 90 km. In addition, extensions of this concept are discussed that allow measurements of the shock wave location and the density profile within the shock layer. Two approaches are identified that appear to be feasible, in which the same laser system is used for the extended measurements as that required for the ambient density measurements.

  20. On stimulated scattering of laser light in inertial fusion energy targets

    International Nuclear Information System (INIS)

    Nikolic, Lj; Skoric, M.M.; Ishiguro, S.; Sato, T.

    2002-11-01

    Propagation of a laser light through regions of an underdense plasma is an active research topic in laser fusion. In particular, a large effort has been invested in studies of stimulated Raman scattering (SRS) and stimulated Brillouin scattering (SBS) which can reflect laser energy and produce energetic particles to preheat a fusion energy target. Experiments, theory and simulations agree on a complex interplay between various laser-plasma instabilities. By particle-in-cell simulations of an underdense electron-plasma, we have found, apart from the standard SRS, a strong backscattering near the electron plasma frequency at densities beyond the quarter critical. This novel instability, recognized in recent experiments as stimulated laser scattering on a trapped electron-acoustic mode (SEAS), is absent from a classical theory of laser-parametric instabilities. A parametric excitation of SEAS instability, is explained by a three-wave resonant decay of the incident laser light into a standing backscattered wave and a slow trapped electron acoustic wave (ω p ). Large SEAS pulsations, eventually suppressed by relativistic heating of electrons, are observed in our simulations. This phenomenon seems relevant to future hohlraum target and fast ignition experiments. (author)

  1. In situ reflectivity investigations of solid/liquid interface during laser backside etching

    International Nuclear Information System (INIS)

    Boehme, R.; Otto, T.; Zimmer, K.

    2006-01-01

    In situ reflectivity measurements of the solid/liquid interface with a pump-probe setup were performed during laser-induced backside wet etching (LIBWE) of fused silica with KrF excimer laser using toluene as absorbing liquid. The intensity, the temporal shape, and the duration of the reflected light measured in dependence on the laser fluence are discussed referring to the surface modification and the bubble formation. The vaporisation of the superheated liquid at the solid interface causes a considerable increase of the reflectivity and gives information about the bubble lifetime. The alterations of the reflectivity after bubbles collapse can be explained with the changed optical properties due to surface modifications of the solid surface. Comparative studies of the reflectivity at different times and the etch rate behaviour in dependence on the laser fluence show that the in situ measured surface modification begins just at the etch threshold fluence and correlates further with etch rate behaviour and the etched surface appearance. The already observed surface modification at LIBWE due to a carbon deposition and structural changes of the near surface region are approved by the changes of the interface reflectivity and emphasizes the importance of the modified surface region in the laser-induced backside wet etching process

  2. The efficiency of photovoltaic cells exposed to pulsed laser light

    Science.gov (United States)

    Lowe, R. A.; Landis, G. A.; Jenkins, P.

    1993-01-01

    Future space missions may use laser power beaming systems with a free electron laser (FEL) to transmit light to a photovoltaic array receiver. To investigate the efficiency of solar cells with pulsed laser light, several types of GaAs, Si, CuInSe2, and GaSb cells were tested with the simulated pulse format of the induction and radio frequency (RF) FEL. The induction pulse format was simulated with an 800-watt average power copper vapor laser and the RF format with a frequency-doubled mode-locked Nd:YAG laser. Averaged current vs bias voltage measurements for each cell were taken at various optical power levels and the efficiency measured at the maximum power point. Experimental results show that the conversion efficiency for the cells tested is highly dependent on cell minority carrier lifetime, the width and frequency of the pulses, load impedance, and the average incident power. Three main effects were found to decrease the efficiency of solar cells exposed to simulated FEL illumination: cell series resistance, LC 'ringing', and output inductance. Improvements in efficiency were achieved by modifying the frequency response of the cell to match the spectral energy content of the laser pulse with external passive components.

  3. Through-transmission laser welding of glass fibre composite: Experimental light scattering identification

    Science.gov (United States)

    Cosson, Benoit; Asséko, André Chateau Akué; Dauphin, Myriam

    2018-05-01

    The purpose of this paper is to develop a cost-effective, efficient and quick to implement experimental optical method in order to predict the optical properties (extinction coefficient) of semi-transparent polymer composites. The extinction coefficient takes into account the effects due to the absorption and the scattering phenomena in a semi-transparent component during the laser processes, i.e. TTLW (through-transmission laser welding). The present method used a laser as light source and a reflex camera equipped with a macro lens as a measurement device and is based on the light transmission measurement through different thickness samples. The interaction between the incident laser beam and the semi-transparent composite is exanimated. The results are presented for the case of a semi-transparent composite reinforced with the unidirectional glass fiber (UD). A numerical method, ray tracing, is used to validate the experimental results. The ray tracing method is appropriate to characterize the light-scattering phenomenon in semi-transparent materials.

  4. Optical properties of p–i–n structures based on amorphous hydrogenated silicon with silicon nanocrystals formed via nanosecond laser annealing

    Energy Technology Data Exchange (ETDEWEB)

    Krivyakin, G. K.; Volodin, V. A., E-mail: volodin@isp.nsc.ru; Kochubei, S. A.; Kamaev, G. N. [Russian Academy of Sciences, Rzhanov Institute of Semiconductor Physics, Siberian Branch (Russian Federation); Purkrt, A.; Remes, Z. [Institute of Physics ASCR (Czech Republic); Fajgar, R. [Institute of Chemical Process Fundamentals of the ASCR (Czech Republic); Stuchliková, T. H.; Stuchlik, J. [Institute of Physics ASCR (Czech Republic)

    2016-07-15

    Silicon nanocrystals are formed in the i layers of p–i–n structures based on a-Si:H using pulsed laser annealing. An excimer XeCl laser with a wavelength of 308 nm and a pulse duration of 15 ns is used. The laser fluence is varied from 100 (below the melting threshold) to 250 mJ/cm{sup 2} (above the threshold). The nanocrystal sizes are estimated by analyzing Raman spectra using the phonon confinement model. The average is from 2.5 to 3.5 nm, depending on the laser-annealing parameters. Current–voltage measurements show that the fabricated p–i–n structures possess diode characteristics. An electroluminescence signal in the infrared (IR) range is detected for the p–i–n structures with Si nanocrystals; the peak position (0.9–1 eV) varies with the laser-annealing parameters. Radiative transitions are presumably related to the nanocrystal–amorphous-matrix interface states. The proposed approach can be used to produce light-emitting diodes on non-refractory substrates.

  5. FEM numerical analysis of excimer laser induced modification in alternating multi-layers of amorphous and nano-crystalline silicon films

    Energy Technology Data Exchange (ETDEWEB)

    Conde, J.C., E-mail: jconde@uvigo.es [Dpto. Fisica Aplicada, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain); Martin, E. [Dpto. Mecanica, Maquinas, Motores Termicos y Fluidos, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain); Stefanov, S. [Dpto. Fisica Aplicada, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain); Alpuim, P. [Departamento de Fisica, Universidade do Minho, 4800-058 Guimaraes (Portugal); Chiussi, S. [Dpto. Fisica Aplicada, Universidade de Vigo, Rua Maxwell s/n, Campus Universitario Lagoas Marcosende, Vigo (Spain)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer nc-Si:H is a material with growing importance for a large-area of nano-electronic, photovoltaic or biomedical devices. Black-Right-Pointing-Pointer UV-ELA technique causes a rapid heating that provokes the H{sub 2} desorption from the Si surface and bulk material. Black-Right-Pointing-Pointer Next, diffusion of P doped nc-Si films and eventually, for high energy densities would be possible to reach the melting point. Black-Right-Pointing-Pointer These multilayer structures consisting of thin alternating a-Si:H(10 nm) and n-doped nc-Si:H(60 nm) films deposited on SiO{sub 2}. Black-Right-Pointing-Pointer To optimize parameters involved in this processing, FEM numerical analysis of multilayer structures have been performed. Black-Right-Pointing-Pointer The numerical results are compared with exhaustive characterization of the experimental results. - Abstract: UV excimer laser annealing (UV-ELA) is an alternative annealing process that, during the last few years, has gained enormous importance for the CMOS nano-electronic technologies, with the ability to provide films and alloys with electrical and optical properties to fit the desired device performance. The UV-ELA of amorphous (a-) and/or doped nano-crystalline (nc-) silicon films is based on the rapid (nanoseconds) formation of temperature profiles caused by laser radiation that is absorbed in the material and lead to crystallisation, diffusion in solid or even in liquid phase. To achieve the desired temperature profiles and to optimize the parameters involved in the processing of hydrogenated nanocrystalline silicon (nc-Si:H) films with the UV-ELA, a numerical analysis by finite element method (FEM) of a multilayer structure has been performed. The multilayer structures, consisting of thin alternating a-Si:H(10 nm) and n-doped nc-Si:H(60 nm) layers, deposited on a glass substrate, has also been experimentally analyzed. Temperature profiles caused by 193 nm radiation with 25

  6. Laser light scatter experiments on plasma focus plant

    International Nuclear Information System (INIS)

    Wenzel, N.

    1985-01-01

    The plasma focus plant is an experiment on nuclear fusion, which is distinguished by a high neutron yield. Constituting an important method of diagnosis in plasma focussing, the laser light scatter method makes it possible, apart from finding the electron temperature and density, to determine the ion temperature resolved according to time and place and further, to study the occurrence of micro-turbulent effects. Starting from the theoretical basis, this dissertation describes light scatter measurements with ruby lasers on the POSEIDON plasma focus. They are given, together with earlier measurements on the Frascati 1 MJ plant and the Heidelberg 12 KJ plant. The development of the plasma parameters and the occurrence of superthermal light scatter events are discussed in connection with the dynamics of the plasma and the neutron emission characteristics of the individual plants. The results support the view that the thermo-nuclear neutron production at the plasma focus is negligible. Although the importance of micro-turbulent mechanisms in producing neutrons cannot be finally judged, important guidelines are given for the spatial and time relationships with plasma dynamics, plasma parameters and neutron emission. The work concludes with a comparison of all light scatter measurements at the plasma focus described in the literature. (orig.) [de

  7. Mechanical properties and polymerization shrinkage of composite resins light-cured using two different lasers.

    Science.gov (United States)

    Kim, Tae-Wan; Lee, Jang-Hoon; Jeong, Seung-Hwa; Ko, Ching-Chang; Kim, Hyung-Il; Kwon, Yong Hoon

    2015-04-01

    The purpose of the present study was to investigate the usefulness of 457 and 473 nm lasers for the curing of composite resins during the restoration of damaged tooth cavity. Monochromaticity and coherence are attractive features of laser compared with most other light sources. Better polymerization of composite resins can be expected. Eight composite resins were light cured using these two lasers and a light-emitting diode (LED) light-curing unit (LCU). To evaluate the degrees of polymerization achieved, polymerization shrinkage and flexural and compressive properties were measured and compared. Polymerization shrinkage values by 457 and 473 nm laser, and LED ranged from 10.9 to 26.8, from 13.2 to 26.1, and from 11.5 to 26.3 μm, respectively. The values by 457 nm laser was significantly different from those by 473 and LED LCU (p0.05). For the tested LCUs, no specific LCU could consistently achieve highest strength and modulus from the specimens tested. Two lasers (457 and 473 nm) can polymerize composite resins to the level that LED LCU can achieve despite inconsistent trends of polymerization shrinkage and flexural and compressive properties of the tested specimens.

  8. The synchrotron light source as a tool for microtechnology

    CERN Document Server

    Harvey, E C

    2002-01-01

    We are all familiar with lathes and milling machines for shaping parts in machine shops and factories. But what if the parts we need to make are significantly smaller than a millimetre, and featuring details even smaller? Semiconductor chip manufacturers have faced these problems and have learnt to use new ways to make devices. No longer are transistors made one at a time, but rather are 'printed' millions at a time, together with their interconnection wiring in a process called photolithography. Light from an excimer laser is directed through masks that incorporate the patterns required and photoexposes surfaces positioned behind the masks. This form of photolithography is today a standard process in semiconductor FAB plants and has several critical advantages in terms of cost, reproducibility, reliability and its ability to scale towards ever smaller and more complex systems

  9. Robotic Laser Coating Removal System

    Science.gov (United States)

    2008-07-01

    using a transverse excitation at atmospheric pressure (TEA) method. o Excimer lasers use reactive gases, such as chlorine and fluorine , mixed with... Varnish , and Related Products on Test Panels.   All topcoats were applied over the primer within the manufacturer’s recommended time and  artificially aged

  10. The monitoring system using laser light for the patient movement during radiation therapy

    International Nuclear Information System (INIS)

    Sano, Naoki; Onishi, Hiroshi; Yamaguchi, Motoshi; Kuriyama, Kengo; Akiyama, Saburou; Nakamura, Osamu; Araki, Tsutomu

    1997-01-01

    Purpose: The purpose of this study is to evaluate the usefulness of a newly developed real-time patient movement monitoring system built into the patient positioning light from the frontal and horizontal view. Materials and Techniques: This system is composed of 4 parts. They are a laser light projector, a retro-reflected tape, a sensor of photo-diode, and an alarm devise. First, this system projects a laser light for the patient movement monitor into the center of the crossed lines of the patient positioning light. The laser light (a diameter of 1.5mm and power of 0.5mW) for the patient movement monitor has a different wave length(633nm) from the patient positioning light. Then it is reflected into the direction of incidence with a retro-reflection tape affixed on three patient positioning points. And the system has a photo-diode which can sense the reflected laser light. This retro-reflected tape is made of tiny high reflective beads of glass which is fixed on a sheet with the thickness of 0.12mm and is able to be cut into any shape. This has a maximum retro-reflection angle of 70 degrees. We can select a tolerance of the patient movement by changing its shape and size. A buzzer strikes and a lamp is turned on to alarm for the error when the retro-reflected laser light is not sensed with the photo-diode. Results: The real-time monitoring accuracy of this system is only 0.17mm in the dimension of error for a selected tolerance of the phantom examination. Conclusion: This patient positioning system can be made simply and inexpensively and has a high monitoring accuracy. We can apply this system for a high-precision irradiation such as the three dimensional irradiation and small target irradiation

  11. Speckle reduction for a laser light sectioning sensor

    Directory of Open Access Journals (Sweden)

    Tutsch Rainer

    2015-01-01

    Full Text Available Automated optical inspection is an important test procedure in electronic circuits assembly. Frequently 3d information is required and laser light sectioning sensors are often applied. However, some effects complicate the reliable automatic detection of the shape of such assemblies and their components. The packages of electronic components often are made of black plastics or ceramics so that the intensity available for the optical detection is quite low, especially in comparison to the surface of the PCBs where the components are mounted on. In addition due to rough surfaces of the components and the coherence length of the laser light speckle structures arise. In the work presented here a piezo actuator is used to oscillate the illuminating laser lines along the direction of the lines. The aim is to reduce the visibility of the speckle structures by averaging while maintaining the geometrical shape of the lines. In addition, image processing methods like segmentation and skeletonization are used to allow the detection of the shape of components and assemblies also if materials with distinct differences in the reflectivity are involved. Investigations include the influence of the parameters amplitude and frequency of the piezo actuator.

  12. Advanced lasers for fusion applications

    International Nuclear Information System (INIS)

    Krupke, W.F.

    1978-11-01

    Projections indicate that MJ/MW laser systems, operating with efficiencies in escess of 1 percent, are required to drive laser fusion power reactors. Moreover, a premium in pellet performance is anticipated as the wavelength of the driver laser system is decreased. Short wavelength laser systems based on atomic selenium (lambda = 0.49μ), terbium molcular vapors (0.55μ), thulium doped dielectric solids (0.46μ), and on pulse compressions of KrF excimer laser radiaton (0.27μ) have been proposed and studied for this purpose. The technological scalability and efficiency of each of these systems is examined in this paper. All of these systems are projected to meet minimum systems requirements. Amont them, the pulse-compressed KrF system is projected to have the highest potential efficiency (6%) and the widest range of systems design options

  13. [Physical treatment methods for acne. Light, laser, photodynamic therapy and peeling].

    Science.gov (United States)

    Borelli, C; Korting, H C

    2010-02-01

    The medical treatment of acne is generally sufficient to meet the expectations of acne patients. However, in a number of situations additional therapeutic approaches may be advisable. There are a wide variety of useful physical methods. They range from electromagnetic waves, usually light, to peeling and manual therapy. Phototherapy of acne includes not just visible light but also laser and flash lamp therapy. The present review provides an overview on the evidence. Visible light, in particular blue light, provides an effective option for treatment of inflammatory acne. Photodynamic therapy also is efficacious; however, it should not be used because of an unfavorable risk-benefit ratio. UV treatment of acne is obsolete. Newer studies on the use of a variety of laser systems and flash lamps have demonstrated in part rewarding results.

  14. Laser coupling to reduced-scale targets at NIF Early Light

    International Nuclear Information System (INIS)

    Hinkel, D E; Schneider, M B; Young, B K; Holder, J P; Langdon, A B; Baldis, H A; Bonanno, G; Bower, D E; Bruns, H C; Campbell, K M; Celeste, J R; Compton, S; Costa, R L; Dewald, E L; Dixit, S N; Eckart, M J; Eder, D C; Edwards, M J; Ellis, A D; Emig, J A; Froula, D H; Glenzer, S H; Hargrove, D; Haynam, C A; Heeter, R F; Henesian, M A; Holtmeier, G; James, D L; Jancaitis, K S; Kalantar, D H; Kamperschroer, J H; Kauffman, R L; Kimbrough, J; Kirkwood, R K; Koniges, A E; Landen, O L; Landon, M; Lee, F D; MacGowan, B J; Mackinnon, A J; Manes, K R; Marshall, C; May, M J; McDonald, J W; Menapace, J; Moses, S I; Munro, D H; Murray, J R; Niemann, C; Pellinen, D; Power, G D; Rekow, V; Ruppe, J A; Schein, J; Shepherd, R; Singh, M S; Springer, P; Still, C H; Suter, L J; Tietbohl, G L; Turner, R E; VanWonterghem, B M; Wallace, R J; Warrick, A; Watts, P; Weber, F; Wegner, P J; Williams, E A; Young, P E

    2005-01-01

    Deposition of maximum laser energy into a small, high-Z enclosure in a short laser pulse creates a hot environment. Such targets were recently included in an experimental campaign using the first four of the 192 beams of the National Ignition Facility [J. A. Paisner, E. M. Campbell, and W. J. Hogan, Fusion Technology 26 26, 755 (1994)], under construction at the University of California Lawrence Livermore National Laboratory. These targets demonstrate good laser coupling, reaching a radiation temperature of 340 eV. In addition, the Raman backscatter spectrum contains features consistent with Brillouin backscatter of Raman forward scatter [A. B. Langdon and D. E. Hinkel, Physical Review Letters 89, 015003 (2002)]. Also, NIF Early Light diagnostics indicate that 20% of the direct backscatter from these reduced-scale targets is in the polarization orthogonal to that of the incident light

  15. Processing of Dielectric Optical Coatings by Nanosecond and Femtosecond UV Laser Ablation

    International Nuclear Information System (INIS)

    Ihlemann, J.; Bekesi, J.; Klein-Wiele, J.H.; Simon, P.

    2008-01-01

    Micro processing of dielectric optical coatings by UV laser ablation is demonstrated. Excimer laser ablation at deep UV wavelengths (248 nm, 193 nm) is used for the patterning of thin oxide films or layer stacks. The layer removal over extended areas as well as sub-μm-structuring is possible. The ablation of SiO2, Al2O3, HfO2, and Ta2O5 layers and layer systems has been investigated. Due to their optical, chemical, and thermal stability, these inorganic film materials are well suited for optical applications, even if UV-transparency is required. Transparent patterned films of SiO2 are produced by patterning a UV-absorbing precursor SiOx suboxide layer and oxidizing it afterwards to SiO2. In contrast to laser ablation of bulk material, in the case of thin films, the layer-layer or layer-substrate boundaries act as predetermined end points, so that precise depth control and a very smooth surface can be achieved. For large area ablation, nanosecond lasers are well suited; for patterning with submicron resolution, femtosecond excimer lasers are applied. Thus the fabrication of optical elements like dielectric masks, pixelated diffractive elements, and gratings can be accomplished.

  16. Dye laser light for high-resolution classical photography

    International Nuclear Information System (INIS)

    Geissler, K.K.

    1982-01-01

    The test run with the bubble chamber HOLEBC in October 1981 offered the opportunity of checking the usefulness of de-speckled dye laser light for illumination purposes in high-resolution classical dark field photography of small bubble chambers. (orig./HSI)

  17. Optical performance of thin films produced by the pulsed laser deposition of SiAlON and Er targets

    Energy Technology Data Exchange (ETDEWEB)

    Camps, I., E-mail: camps@io.cfmac.csic.es [Laser Processing Group, Instituto de Óptica, CSIC, C/Serrano 121, 28006 Madrid (Spain); Ramírez, J.M. [MIND-IN2UB, Departament d’Electrònica, Universitat de Barcelona, c/Martí i Franqués 1, 08028 Barcelona (Spain); Mariscal, A.; Serna, R. [Laser Processing Group, Instituto de Óptica, CSIC, C/Serrano 121, 28006 Madrid (Spain); Garrido, B. [MIND-IN2UB, Departament d’Electrònica, Universitat de Barcelona, c/Martí i Franqués 1, 08028 Barcelona (Spain); Perálvarez, M.; Carreras, J. [IREC, Fundació Privada Institut de Recerca en Energia de Catalunya (Spain); Barradas, N.P.; Alves, L.C. [C" 2TN, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10, 2695-066 Bobadela (Portugal); Alves, E. [IPFN, Instituto Superior Técnico, Universidade de Lisboa, E.N. 10, 2695-066 Bobadela (Portugal)

    2015-05-01

    Highlights: • PLD production of Er-doped thin films from a low cost commercial SiAlON target. • The role of the ablation fluence on the composition, optical properties as well as on the light emission performance at 1.5 μm. • The optimized performance is obtained for the samples deposited at the higher used ablation energy density. Further improvement was achieved through annealing. - Abstract: We report the preparation and optical performance of thin films produced by pulsed laser deposition in vacuum at room temperature, by focusing an ArF excimer laser onto two separate targets: a commercial ceramic SiAlON and a metallic Er target. As a result of the alternate deposition Er:SiAlON films were formed. The as grown films exhibited an Er-related emission peaking at 1532 nm. The role of the PLD energy density during deposition on the final matrix film was investigated, in order to achieve an optimized matrix composition with enhanced optical properties, and its effect on the light emission performance.

  18. Lasers in the automobile industry

    Science.gov (United States)

    Roessler, David M.; Uddin, Nasin

    1996-04-01

    The use of lasers for automotive materials processing is reviewed both from an historical perspective and in terms of current trends. The initial lead gained in North America has subsequently given way to the remarkable growth in the use of lasers in the Japanese automotive industry. The latter's dominance has resulted in cutting being the most common laser machining application on a global basis, even though welding predominates in the US. About 98% of all automotive laser materials processing employs either CO2 or Nd:YAG lasers, although there are special applications where the excimer or other lasers can be found. This paper discusses two of the processes currently receiving most attention. Laser technology is not stagnant and the automotive industry continues to benefit from the continuing developments. However, even more striking growth can be expected as the whole process of automotive manufacture is being re-examined in response to the demands for more fuel- efficient and environmentally friendly, but still affordable and satisfying, vehicles.

  19. Setting up and performance of a laser enhanced ionisation spectrometer

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.; Razvi, M.A.N.

    1990-01-01

    A laser enhanced ionisation (LEI) spectrometer has been successfuly set up around an excimer laser pumped dye laser. The performance of the spectrometer has been tested by analysing sodium in water solutions. A straight line working curve has been obtained in the concentration range of 1-1000 ng/ml of Na. The effect of parameters like laser power, ion collector electrode voltage and the load resistance on LEI signals has been investigated. The spectrometer is useful not only for analytical purposes but also for laser spectroscopic studies of species formed in flames, study of phenomenon of combustion etc. (author). 1 tab ., 10 figs., 5 refs

  20. A 3 ps synchronised multi-frame photographic diagnostic for target experiments with the iodine laser

    International Nuclear Information System (INIS)

    Maaswinkel, A.G.M.; Sigel, R.; Baumhacker, H.; Brederlow, G.

    1982-10-01

    A laser system is described with which we obtain a sequence of 6 pictures (interferograms or shadowgrams) of the plasma produced by the iodine laser on solid targets. The system consists of a synchronously pumped dye laser amplified in dye cells pumped by an excimer laser. It delivers a pulse with an energy of 400 μJ and a length of 3 ps at a wavelength of 580 nm that is highly synchronous with the iodine pulse. (orig.)

  1. Changes in Cell Viability of Wounded Fibroblasts following Laser Irradiation in Broad-Spectrum or Infrared Light

    International Nuclear Information System (INIS)

    Hawkins, D.; Abrahamse, H.

    2007-01-01

    Objective. This study aimed to establish if broad-spectrum or infrared (IR) light in combination with laser therapy can assist phototherapy to improve the cell function of wounded cells. Background. The effect of laser light may be partly or completely reduced by broad-spectrum light. Methods. Wounded human skin fibroblasts were irradiated with 5 J/cm2 using a helium-neon laser, a diode laser, or an Nd:YAG laser in the dark, in the light, or in IR. Changes in cell viability were evaluated by cell morphology, ATP cell viability, LDH membrane integrity, and caspase 3/7 as an early marker of apoptosis. Results. Wounded cells exposed to 5 J/cm2 using 632.8 nm in the dark or 830 nm in the light or 1064 nm in the dark showed an increase in ATP viability, an increase in cytokine expression, and a decrease in LDH cytotoxicity indicating that the metabolic activity of the wounded cells was stimulated. Conclusion. Wounded cells irradiated in IR light showed an undesirable thermal effect that was proportional to the duration of exposure.

  2. Survey on modern pulsed high power lasers

    International Nuclear Information System (INIS)

    Witte, K.J.

    1985-01-01

    The requirements to be met by lasers for particle acceleration are partially similar to those already known for fusion lasers. The power level wanted in both caes is up to 100 TW or even more. The pulse durations favourable for laser accelerators are in the range from 1 ps to 1000 ps whereas fusion lasers require several ns. The energy range for laser accelerators is thus correspondingly smaller than that for fusion lasers: 1-100 kJ versus several 100 kJ. The design criteria of lasers meeting the requirements are discussed in the following. The CO 2 , iodine, Nd:glass and excimer lasers are treated in detail. The high repetition rate aspect will not be particularly addressed since for the present generation of lasers the wanted rates of far above 1 Hz are completely out of scope. Moreover, for the demonstration of principle these rates are not needed. (orig./HSI)

  3. Measurement of thermal plasma jet temperature and velocity by laser light lineshape analysis

    International Nuclear Information System (INIS)

    Snyder, S.C.; Reynolds, L.D.

    1991-01-01

    Two important parameters of thermal plasma jets are kinetic or gas temperatures and flow velocity. Gas temperatures have been traditionally measured using emission spectroscopy, but this method depends on either the generally unrealistic assumption of the existence of local thermodynamic equilibrium (LTE) within the plasma, or the use of various non-LTE or partial LTE models to relate the intensity of the emission lines to the gas temperature. Plasma jet velocities have been measured using laser Doppler velocimetry on particles injected into the plasma. However, this method is intrusive and it is not known how well the particle velocities represent the gas velocity. Recently, plasma jet velocities have been measured from the Doppler shift of laser light scattered by the plasma. In this case, the Doppler shift was determined from the difference in the transmission profile of a high resolution monochromator between red shifted and blue shifted scattered light. A direct approach to measuring localized temperatures and velocities is afforded by high resolution scattered light lineshape measurements. The linewidth of laser light scattered by atoms and ions can be related to the kinetic temperature without LTE assumptions, while a shift in the peak position relative to the incident laser lineshape yields the gas velocity. We report in this paper work underway to measure gas temperatures and velocities in an argon thermal plasma jet using high resolution lineshape analysis of scattered laser light

  4. Generation of various carbon nanostructures in water using IR/UV laser ablation

    International Nuclear Information System (INIS)

    Mortazavi, Seyedeh Zahra; Parvin, Parviz; Reyhani, Ali; Mirershadi, Soghra; Sadighi-Bonabi, Rasoul

    2013-01-01

    A wide variety of carbon nanostructures were generated by a Q-switched Nd : YAG laser (1064 nm) while mostly nanodiamonds were created by an ArF excimer laser (193 nm) in deionized water. They were characterized by transmission electron microscopy, Raman spectroscopy and x-ray photoelectron spectroscopy. It was found that the IR laser affected the morphology and structure of the nanostructures due to the higher inverse bremsstrahlung absorption rate within the plasma plume with respect to the UV laser. Moreover, laser-induced breakdown spectroscopy was carried out so that the plasma created by the IR laser was more energetic than that generated by the UV laser. (paper)

  5. Characterization of thermal plasmas by laser light scattering

    International Nuclear Information System (INIS)

    Snyder, S.C.; Lassahn, G.D.; Reynolds, L.D.; Fincke, J.R.

    1993-01-01

    Characterization of an atmospheric pressure free-burning arc discharge and a plasma jet by lineshape analysis of scattered laser light is described. Unlike emission spectroscopy, this technique provides direct measurement of plasma gas temperature, electron temperature and electron density without the assumption of local thermodynamic equilibrium (LTE). Plasma gas velocity can also be determined from the Doppler shift of the scattered laser light. Radial gas temperature, electron temperature and electron density profiles are presented for an atmospheric pressure argon free-burning arc discharge. These results show a significant departure from LTE in the arc column, contradicting results obtained from emission spectroscopy. Radial gas temperature and gas velocity profiles in the exit plane of a subsonic atmospheric pressure argon plasma jet are also presented. In this case, the results show the plasma jet is close to LTE in the center, but not in the fringes. The velocity profile is parabolic

  6. New polymers containing BF2-benzoylacetonate groups. Synthesis, luminescence, excimer and exciplex formation

    International Nuclear Information System (INIS)

    Fedorenko, Elena V.; Mirochnik, Anatolii G.; Beloliptsev, Anton Yu.

    2017-01-01

    In the present study, a new synthetic method for the functionalization of polystyrene (PS) and (styrene-methyl methacrylate) copolymer has been developed. Using the new method, polymers containing BF 2 -benzoylacetonate groups have been obtained through double acylation by acetic anhydride with boron trifluoride. Luminescence of the produced polymers in solutions and films has been studied. Quantum yields of polymer solution luminescence are significantly higher than those of the low-molecular-weight analog – boron difluoride benzoylacetonate. For the polymer, in which styrene fragments are separated by methyl methacrylate groups, at low concentrations of the polymer in solution one observes the monomer luminescence of BF 2 -benzoylacetonate groups, while at high concentrations – the excimer luminescence. In case of PS-based polymers, in which BF 2 -benzoylacetonate groups and phenyl rings are not separated, in diluted solutions one observes the fluorescence of the intramolecular exciplexes, while at the concentration increase – the luminescence of intermolecular exciplexes. The ability of excimer formation is responsible for the increased photostability of the produced polymers. - Highlights: •Polymers containing BF 2 -benzoylacetonate groups have been synthesized. •Luminescence of the produced polymers in solutions and films has been studied. •Formation of excimers and exciplexes in solution has been revealed. •Formation of excimers in films increases their photostability.

  7. Nano-crystallization in ZnO-doped In_2O_3 thin films via excimer laser annealing for thin-film transistors

    International Nuclear Information System (INIS)

    Fujii, Mami N.; Ishikawa, Yasuaki; Bermundo, Juan Paolo Soria; Uraoka, Yukiharu; Ishihara, Ryoichi; Cingel, Johan van der; Mofrad, Mohammad R. T.; Kawashima, Emi; Tomai, Shigekazu; Yano, Koki

    2016-01-01

    In a previous work, we reported the high field effect mobility of ZnO-doped In_2O_3 (IZO) thin film transistors (TFTs) irradiated by excimer laser annealing (ELA) [M. Fujii et al., Appl. Phys. Lett. 102, 122107 (2013)]. However, a deeper understanding of the effect of ELA on the IZO film characteristics based on crystallinity, carrier concentrations, and optical properties is needed to control localized carrier concentrations for fabricating self-aligned structures in the same oxide film and to adequately explain the physical characteristics. In the case of as-deposited IZO film used as the channel, a high carrier concentration due to a high density of oxygen vacancies was observed; such a film does not show the required TFT characteristics but can act as a conductive film. We achieved a decrease in the carrier concentration of IZO films by crystallization using ELA. This means that ELA can form localized conductive or semi-conductive areas on the IZO film. We confirmed that the reason for the carrier concentration decrease was the decrease of oxygen-deficient regions and film crystallization. The annealed IZO films showed nano-crystalline phase, and the temperature at the substrate was substantially less than the temperature limit for flexible films such as plastic, which is 50°C. This paves the way for the formation of self-aligned structures and separately formed conductive and semi-conductive regions in the same oxide film.

  8. FEATURES OF OUTFLOW OF INTRAOCULAR LIQUID AFTER AN EKSIMERLAZER SKLEREKTOMY (PILOT STUDY

    Directory of Open Access Journals (Sweden)

    E. A. Korchuganova

    2017-01-01

    Full Text Available Modern approaches to surgical glaucoma treatment is based on the safe and effective methods. In recent years, great attention is paid to the techniques of stimulating uveoscleral path outtake aqueous humor from the eye. Uveoscleral space in the extended outflow pathways is dominant and constitutes about 72%. Sclera is a field of the greatest interest, as the end stages of the outflow of aqueous humor via the uveoscleral path. The aim of the study was to investigate the influence of excimer laser sclerectomy on the drainage function of the eye and development of a mathematical model based on the permeability of the sclera of the amount of laser ablation at a defined area of laser exposure and the level of IOP. Studies were conducted on 12 human cadaver eyes isolated person. The domestic excimer laser “MicroScan Vizum” with a wavelength of 193нм (0,193 µm was used for the thinning of sclera. In the experiment used a special computer program provided ablation of scleral tissue, the scleral bed forming a rectangular shape with a size 7,0x5,0 mm. the Depth of influence started from 100 microns to 600 microns in increments of 50 µn. The exposure was carried out at a constant perfusion pressure of 25 mm Hg After each impact was measured of the coefficient ease the outflow. A correlation was established between the factor and effective features, i.e., between the excimer laser deep sclerectomy (µm and ratio of lightness outflow (mm3/min/mm Hg.St. Thinning of the sclera leads to an improvement of its permeability and increasing the coefficient ease the outflow. A mathematical model, allowing to achieve the desired ratio of lightness outflow experiment by excimer laser sclerectomy was developed. The mathematical model has the form of the regression equation.The sclera is a promising object for further developments in the surgical treatment of glaucoma. Laser ablation of the sclera leads to an improvement of outflow via the uveoscleral path and

  9. High-energy gamma-ray beams from Compton-backscattered laser light

    International Nuclear Information System (INIS)

    Sandorfi, A.M.; LeVine, M.J.; Thorn, C.E.; Giordano, G.; Matone, G.

    1983-01-01

    Collisions of light photons with relativistic electrons have previously been used to produce polarized #betta#-ray beams with modest (-10%) resolution but relatively low intensity. In contrast, the LEGS project (Laser + Electron Gamma Source) at Brookhaven will produce a very high flux (>2 x 10 7 s - 1 ) of background-free polarized #betta# rays whose energy will be determined to a high accuracy (δE = 2.3 MeV). Initially, 300(420)-MeV #betta# rays will be produced by backscattering uv light from the new 2.5(3.0)-GeV X-ray storage ring of the National Synchrotron Light Source (NSLS). The LEGS facility will operate as one of many passive users of the NSLS. In a later stage of the project, a Free Electron Laser is expectred to extend the #betta#-ray energy up to 700 MeV

  10. High-energy gamma-ray beams from Compton-backscattered laser light

    Energy Technology Data Exchange (ETDEWEB)

    Sandorfi, A.M.; LeVine, M.J.; Thorn, C.E.; Giordano, G.; Matone, G.

    1983-01-01

    Collisions of light photons with relativistic electrons have previously been used to produce polarized ..gamma..-ray beams with modest (-10%) resolution but relatively low intensity. In contrast, the LEGS project (Laser + Electron Gamma Source) at Brookhaven will produce a very high flux (>2 x 10/sup 7/ s/sup -1/) of background-free polarized ..gamma.. rays whose energy will be determined to a high accuracy (..delta..E = 2.3 MeV). Initially, 300(420)-MeV ..gamma.. rays will be produced by backscattering uv light from the new 2.5(3.0)-GeV X-ray storage ring of the National Synchrotron Light Source (NSLS). The LEGS facility will operate as one of many passive users of the NSLS. In a later stage of the project, a Free Electron Laser is expectred to extend the ..gamma..-ray energy up to 700 MeV.

  11. Laser technologies for laser accelerators. Annual report

    International Nuclear Information System (INIS)

    1985-01-01

    The primary result of the work reported is the determination of laser system architectures that satsify the requirements of high luminosity, high energy (about 1 TeV), electron accelerators. It has been found that high laser efficiency is a very hard driver for these accelerators as the total average laser output optical power is likely to fall above 10 MW. The luminosity requires rep rates in the kHz range, and individual pulse lengths in the 1-10 psec range are required to satisfy acceleration gradient goals. CO 2 and KrF lasers were chosen for study because of their potential to simultaneously satisfy the given requirements. Accelerator luminosity is reviewed, and requirements on laser system average power and rep rate are determined as a function of electron beam bunch parameters. Laser technologies are reviewed, including CO 2 , excimers, solid state, and free electron lasers. The proposed accelerator mechanisms are summarized briefly. Work on optical transport geometries for near and far field accelerators are presented. Possible exploitation of the CO 2 and DrF laser technology to generate the required pulse lengths, rep rates, and projected efficiencies is illustrated and needed development work is suggested. Initial efforts at developing a 50 GeV benchmark conceptual design and a 100 MeV demonstration experiment conceptual design are presented

  12. Quantum Dot Laser for a Light Source of an Athermal Silicon Optical Interposer

    Directory of Open Access Journals (Sweden)

    Nobuaki Hatori

    2015-04-01

    Full Text Available This paper reports a hybrid integrated light source fabricated on a silicon platform using a 1.3 μm wavelength quantum dot array laser. Temperature insensitive characteristics up to 120 °C were achieved by the optimum quantum dot structure and laser structure. Light output power was obtained that was high enough to achieve an optical error-free link of a silicon optical interposer. Furthermore, we investigated a novel spot size convertor in a silicon waveguide suitable for a quantum dot laser for lower energy cost operation of the optical interposer.

  13. Laser Plasma Instability (LPI) Driven Light Scattering Measurements with Nike KrF Laser

    Science.gov (United States)

    Oh, J.; Weaver, J. L.; Kehne, D. M.; Obenschain, S. P.; McLean, E. A.; Lehmberg, R. H.

    2008-11-01

    With the short wavelength (248 nm), large bandwidth (1˜2 THz), and ISI beam smoothing, Nike KrF laser is expected to have higher LPI thresholds than observed at other laser facilities. Previous measurements using the Nike laser [J. L. Weaver et al, Phys. Plasmas 14, 056316 (2007)] showed no LPI evidence from CH targets up to I˜2x10^15 W/cm^2. For further experiments to detect LPI excitation, Nike capabilities have been extended to achieve higher laser intensities by tighter beam focusing and higher power pulses. This talk will present results of a recent LPI experiment with the extended Nike capabilities focusing on light emission data in spectral ranges relevant to the Raman (SRS) and Two-Plasmon Decay (TPD) instabilities. The primary diagnostics were time-resolved spectrometers with an absolute-intensity-calibrated photodiode array in (0.4˜0.8)φ0 and a streak camera near 0.5φ0. The measurements were conducted at laser intensities of 10^15˜10^16 W/cm^2 on planar targets of CH solids and RF foams.

  14. Lasers in endodontics: an overview

    Science.gov (United States)

    Frentzen, Matthias; Braun, Andreas; Koort, Hans J.

    2002-06-01

    The interest in endodontic use of dental laser systems is increasing. Developing laser technology and a better understanding of laser effects widened the spectrum of possible endodontic indications. Various laser systems including excimer-, argon+-, diode-, Nd:YAG-, Er:YAG- and CO2-lasers are used in pulp diagnosis, treatment of hypersensitivity, pulp capping, sterilization of root canals, root canal shaping and obturation or apicoectomy. With the development of new delivery systems - thin and flexible fibers - for many different wavelengths laser applications in endodontics may increase. Since laser devices are still relatively costly, access to them is limited. Most of the clinical applications are laser assisted procedures such as the removing of pulp remnants and debris or disinfection of infected root canals. The essential question is whether a laser can provide improved treatment over conventional care. To perform laser therapy in endodontics today different laser types with adopted wavelengths and pulse widths are needed, each specific to a particular application. Looking into the future we will need endodontic laser equipment providing optimal laser parameters for different treatment modalities. Nevertheless, the quantity of research reports from the last decade promises a genuine future for lasers in endodontics.

  15. Compact RGBY light sources with high luminance for laser display applications

    Science.gov (United States)

    Paschke, Katrin; Blume, Gunnar; Werner, Nils; Müller, André; Sumpf, Bernd; Pohl, Johannes; Feise, David; Ressel, Peter; Sahm, Alexander; Bege, Roland; Hofmann, Julian; Jedrzejczyk, Daniel; Tränkle, Günther

    2018-02-01

    Watt-class visible laser light with a high luminance can be created with high-power GaAs-based lasers either directly in the red spectral region or using single-pass second harmonic generation (SHG) for the colors in the blue-yellow spectral region. The concepts and results of red- and near infrared-emitting distributed Bragg reflector tapered lasers and master oscillator power amplifier systems as well as their application for SHG bench-top experiments and miniaturized modules are presented. Examples of these high-luminance light sources aiming at different applications such as flying spot display or holographic 3D cinema are discussed in more detail. The semiconductor material allows an easy adaptation of the wavelength allowing techniques such as six-primary color 3D projection or color space enhancement by adding a fourth yellow color.

  16. Modification in oxidative processes in muscle tissues exposed to laser- and light-emitting diode radiation.

    Science.gov (United States)

    Monich, Victor A; Bavrina, Anna P; Malinovskaya, Svetlana L

    2018-01-01

    Exposure of living tissues to high-intensity red or near-infrared light can produce the oxidative stress effects both in the target zone and adjacent ones. The protein oxidative modification (POM) products can be used as reliable and early markers of oxidative stress. The contents of modified proteins in the investigated specimens can be evaluated by the 2,4-dinitrophenylhydrazine assay (the DNPH assay). Low-intensity red light is able to decrease the activity of oxidative processes and the DNPH assay data about the POM products in the biological tissues could show both an oxidative stress level and an efficiency of physical agent protection against the oxidative processes. Two control groups of white rats were irradiated by laser light, the first control group by red light and the second one by near-infrared radiation (NIR).Two experimental groups were consequently treated with laser and red low-level light-emitting diode radiation (LED). One of them was exposed to red laser light + LED and the other to NIR + LED. The fifth group was intact. Each group included ten animals. The effect of laser light was studied by methods of protein oxidative modifications. We measured levels of both induced and spontaneous POM products by the DNPH assay. The dramatic increase in levels of POM products in the control group samples when compared with the intact group data as well as the sharp decrease in the POM products in the experimental groups treated with LED low-level light were statistically significant (p ≤ 0.05). Exposure of skeletal muscles to high-intensity red and near-infrared laser light causes oxidative stress that continues not less than 3 days. The method of measurement of POM product contents by the DNPH assay is a reliable test of an oxidative process rate. Red low-intensity LED radiation can provide rehabilitation of skeletal muscle tissues treated with high-intensity laser light.

  17. Lighting up medicine with lasers

    International Nuclear Information System (INIS)

    Durrani, M.

    2004-01-01

    If you have ever shone a torch onto the back of your hand, you will know that your palm glows red. Haemoglobin in the blood absorbs almost all visible radiation at wavelengths below about 600nm, letting only red light pass through. Disappointingly, however, bones and other anatomical structures are impossible to see. Light is scattered so strongly by soft tissue that even a parallel beam becomes diffuse after travelling just a millimetre into the skin. Despite this superficial drawback, light is widely used in modern medicine. It can be reflected, refracted, absorbed, emitted and amplified. Light can be used to detect tumours, to take pictures of your stomach, or - in laser form - to remove cancerous tissue. Light in the 700-1300 nm range, known as the sup t herapeutic window sup , yields molecular information about fat, water and lipids, as well as the oxygenation of haemoglobin. For some, the holy grail in biomedical optics is a portable Star Trek style device that latter-day Dr McCoys can shine over patients to provide a diagnosis and therapy all in one. Optical scientists and engineers have developed a vast range of sophisticated light-based techniques for medical applications. But one of the most common biomedical research tools remains the optical microscope, which is almost the only way of studying biological processes in living tissue at the sub-micron cellular level. Although it might seem rather old-fashioned, microscopy has recently returned to the front line of biological research. In the August issue of Physics World Matin Durrani describes the latest developments in the field of biomedical optics. (U.K.)

  18. Simulation of pulsed dielectric barrier discharge xenon excimer lamp

    International Nuclear Information System (INIS)

    Bogdanov, E A; Kudryavtsev, A A; Arslanbekov, R R; Kolobov, V I

    2004-01-01

    Recently, it has been shown that the efficiency of excimer lamps can be drastically increased in a pulsed regime. A one-dimensional simulation of pulsed excimer lamps has been performed by Carman and Mildren (2003 J. Phys. D: Appl. Phys. 36 19) (C and M). However, some computational results of the work of C and M are questionable and need to be revisited. In this paper, a dielectric barrier discharge (DBD) in xenon has been simulated for operating conditions similar to those of C and M to better understand plasma dynamics in a pulsed regime. Our simulation results differ considerably from the computational results of C and M. Although these differences do not affect profoundly the plasma macro parameters measured in the C and M experiments, they offer a better understanding of plasma dynamics in pulsed DBDs and form a solid foundation for computational optimization of excimer lamps. It was found that the dynamics of breakdown and the current pulse depend significantly on the initial densities of species after a previous pulse, and so it is important to accurately simulate the plasma evolution in both the afterglow and active stages. It seems possible to modify the power deposition in the plasma by varying external discharge parameters such as the amplitude and the rise time of the applied voltage, and to modify the plasma composition by changing the pulse repetition rate and plasma decay in the afterglow stage

  19. Polycrystalline diamond film UV detectors for excimer lasers

    International Nuclear Information System (INIS)

    Ralchenko, V G; Savel'ev, A V; Konov, Vitalii I; Mazzeo, G; Spaziani, F; Conte, G; Polyakov, V I

    2006-01-01

    Photoresistive metal-semiconductor-metal detectors based on polycrystalline diamond films are fabricated for recording cw and pulsed UV radiation. The detectors have a high spectral selectivity (the UV-to-VIS response ratio is ∼10 5 ) and a temporal resolution of the order of 10 9 s. 'Solar-blind' photostable diamond detectors are promising for applications in UV lithography, laser micromachining, medicine, and space research. (letters)

  20. Laser precision microfabrication in Japan

    Science.gov (United States)

    Miyamoto, Isamu; Ooie, Toshihiko; Takeno, Shozui

    2000-11-01

    Electronic devices such as handy phones and micro computers have been rapidly expanding their market recent years due to their enhanced performance, down sizing and cost down. This has been realized by the innovation in the precision micro- fabrication technology of semiconductors and printed wiring circuit boards (PWB) where laser technologies such as lithography, drilling, trimming, welding and soldering play an important role. In phot lithography, for instance, KrF excimer lasers having a resolution of 0.18 micrometers has been used in production instead of mercury lamp. Laser drilling of PWB has been increased up to over 1000 holes per second, and approximately 800 laser drilling systems of PWB are expected to be delivered in the world market this year, and most of these laser processing systems are manufactured in Japan. Trend of laser micro-fabrication in Japanese industry is described along with recent topics of R&D, government supported project and future tasks of industrial laser precision micro-fabrication on the basis of the survey conducted by Japan laser Processing Society.