WorldWideScience

Sample records for excessively variable spirometry

  1. Spirometry

    Science.gov (United States)

    Spirometry Overview Spirometry (spy-ROM-uh-tree) is a common office test used to assess how well your lungs work by ... much you exhale and how quickly you exhale. Spirometry is used to diagnose asthma, chronic obstructive pulmonary ...

  2. Research of Precataclysmic Variables with Radius Excesses

    Science.gov (United States)

    Deminova, N. R.; Shimansky, V. V.; Borisov, N. V.; Gabdeev, M. M.; Shimanskaya, N. N.

    2017-06-01

    The results of spectroscopic observations of the pre-cataclysmic variable NSVS 14256825, which is a HW Vir binary system, were analyzed. The chemical composition is determined, the radial velocities and equivalent widths of a given star are measured. The fundamental parameters of the components were determined (R1 = 0.166 R⊙ , M2 = 0.100 M⊙ , R2 = 0.122 R⊙). It is shown that the secondary component has a mass close to the mass of brown dwarfs. A comparison of two close binary systems is made: HS 2333 + 3927 and NSVS 14256825. A radius-to-mass relationship for the secondary components of the studied pre-cataclysmic variables is constructed. It is concluded that an excess of radii relative to model predictions for MS stars is observed in virtually all systems.

  3. VARIABILITY OF THE INFRARED EXCESS OF EXTREME DEBRIS DISKS

    International Nuclear Information System (INIS)

    Meng, Huan Y. A.; Rieke, George H.; Su, Kate Y. L.; Rujopakarn, Wiphu; Ivanov, Valentin D.; Vanzi, Leonardo

    2012-01-01

    Debris disks with extremely large infrared excesses (fractional luminosities >10 –2 ) are rare. Those with ages between 30 and 130 Myr are of interest because their evolution has progressed well beyond that of protoplanetary disks (which dissipate with a timescale of order 3 Myr), yet they represent a period when dynamical models suggest that terrestrial planet building may still be progressing through large, violent collisions that could yield large amounts of debris and large infrared excesses. For example, our Moon was formed through a violent collision of two large protoplanets during this age range. We report two disks around the solar-like stars ID8 and HD 23514 in this age range where the 24 μm infrared excesses vary on timescales of a few years, even though the stars are not variable in the optical. Variations this rapid are difficult to understand if the debris is produced by collisional cascades, as it is for most debris disks. It is possible that the debris in these two systems arises in part from condensates from silicate-rich vapor produced in a series of violent collisions among relatively large bodies. If their evolution is rapid, the rate of detection of extreme excesses would indicate that major collisions may be relatively common in this age range.

  4. Spirometry in children.

    Science.gov (United States)

    Jat, Kana Ram

    2013-06-01

    Respiratory disorders are responsible for considerable morbidity and mortality in children. Spirometry is a useful investigation for diagnosing and monitoring a variety of paediatric respiratory diseases, but it is underused by primary care physicians and paediatricians treating children with respiratory disease. We now have a better understanding of respiratory physiology in children, and newer computerised spirometry equipment is available with updated regional reference values for the paediatric age group. This review evaluates the current literature for indications, test procedures, quality assessment, and interpretation of spirometry results in children. Spirometry may be useful for asthma, cystic fibrosis, congenital or acquired airway malformations and many other respiratory diseases in children. The technique for performing spirometry in children is crucial and is discussed in detail. Most children, including preschool children, can perform acceptable spirometry. Steps for interpreting spirometry results include identification of common errors during the test by applying acceptability and repeatability criteria and then comparing test parameters with reference standards. Spirometry results depict only the pattern of ventilation, which may be normal, obstructive, restrictive, or mixed. The diagnosis should be based on both clinical features and spirometry results. There is a need to encourage primary care physicians and paediatricians treating respiratory diseases in children to use spirometry after adequate training.

  5. Official American Thoracic Society technical standards: spirometry in the occupational setting.

    Science.gov (United States)

    Redlich, Carrie A; Tarlo, Susan M; Hankinson, John L; Townsend, Mary C; Eschenbacher, William L; Von Essen, Susanna G; Sigsgaard, Torben; Weissman, David N

    2014-04-15

    This document addresses aspects of the performance and interpretation of spirometry that are particularly important in the workplace, where inhalation exposures can affect lung function and cause or exacerbate lung diseases, such as asthma, chronic obstructive pulmonary disease, or fibrosis. Issues that previous American Thoracic Society spirometry statements did not adequately address with respect to the workplace were identified for systematic review. Medline 1950-2012 and Embase 1980-2012 were searched for evidence related to the following: training for spirometry technicians; testing posture; appropriate reference values to use for Asians in North America; and interpretative strategies for analyzing longitudinal change in lung function. The evidence was reviewed and technical recommendations were developed. Spirometry performed in the work setting should be part of a comprehensive workplace respiratory health program. Effective technician training and feedback can improve the quality of spirometry testing. Posture-related changes in FEV1 and FVC, although small, may impact interpretation, so testing posture should be kept consistent and documented on repeat testing. Until North American Asian-specific equations are developed, applying a correction factor of 0.88 to white reference values is considered reasonable when testing Asian American individuals in North America. Current spirometry should be compared with previous tests. Excessive loss in FEV1 over time should be evaluated using either a percentage decline (15% plus loss expected due to aging) or one of the other approaches discussed, taking into consideration testing variability, worker exposures, symptoms, and other clinical information. Important aspects of workplace spirometry are discussed and recommendations are provided for the performance and interpretation of workplace spirometry.

  6. Variables of excessive computer internet use in childhood and adolescence

    OpenAIRE

    Thalemann, Ralf

    2010-01-01

    The aim of this doctoral thesis is the characterization of excessive computer and video gaming in terms of a behavioral addiction. Therefore, the development of a diagnostic psychometric instrument was central to differentiate between normal and pathological computer gaming in adolescence. In study 1, 323 children were asked about their video game playing behavior to assess the prevalence of pathological computer gaming. Data suggest that excessive computer and video game players use thei...

  7. Spirometry in Greenland

    DEFF Research Database (Denmark)

    Nielsen, Lasse Overballe; Olsen, Sequssuna; Jarbøl, D. E.

    2016-01-01

    be common. International guidelines recommend the usage of spirometry as a golden standard for diagnosing COPD. The current number of spirometries performed among patients treated with medication targeting obstructive pulmonary disease in Greenland remains unexplored. Objective. To estimate the prevalence...... of patients aged 50 years or above treated with medication targeting obstructive pulmonary disease and the extent to which spirometry was performed among them within 2 years. Design. An observational, cross-sectional study based on the review of data obtained from electronic medical records in Greenland...... of the identified users of medication targeting obstructive pulmonary disease. Information on age, gender, town and spirometry was registered for each patient within the period from October 2013 to October 2015. Results. The prevalence of patients treated with medication targeting obstructive pulmonary disease aged...

  8. Spirometry in primary care

    Science.gov (United States)

    Coates, Allan L; Graham, Brian L; McFadden, Robin G; McParland, Colm; Moosa, Dilshad; Provencher, Steeve; Road, Jeremy

    2013-01-01

    Canadian Thoracic Society (CTS) clinical guidelines for asthma and chronic obstructive pulmonary disease (COPD) specify that spirometry should be used to diagnose these diseases. Given the burden of asthma and COPD, most people with these diseases will be diagnosed in the primary care setting. The present CTS position statement was developed to provide guidance on key factors affecting the quality of spirometry testing in the primary care setting. The present statement may also be used to inform and guide the accreditation process for spirometry in each province. Although many of the principles discussed are equally applicable to pulmonary function laboratories and interpretation of tests by respirologists, they are held to a higher standard and are outside the scope of the present statement. PMID:23457669

  9. Computer assisted spirometry.

    Science.gov (United States)

    Hansen, D J; Toy, V M; Deininger, R A; Collopy, T K

    1983-06-01

    Three of the most popular microcomputers, the TRS-80 Model I, the APPLE II+, and the IBM Personal Computer were connected to a spirometer for data acquisition and analysis. Simple programs were written which allow the collection, analysis and storage of the data produced during spirometry. Three examples demonstrate the relative ease for automating spirometers.

  10. Noncontact spirometry with a webcam

    Science.gov (United States)

    Liu, Chenbin; Yang, Yuting; Tsow, Francis; Shao, Dangdang; Tao, Nongjian

    2017-05-01

    We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vital capacity, and peak expiratory flow rate. We validate the accuracy of the method by comparing the data with those simultaneously recorded with a gold standard reference method and examine the reliability of the noncontact spirometry with a pilot study including 16 subjects. This work demonstrates that the noncontact method can provide accurate and reliable spirometry tests with a webcam. Compared to the traditional spirometers, the present noncontact spirometry does not require using a spirometer, breathing into a mouthpiece, or wearing a nose clip, thus making spirometry test more easily accessible for the growing population of asthma and chronic obstructive pulmonary diseases.

  11. Pilot program on distance training in spirometry testing - the technology feasibility study.

    Science.gov (United States)

    Nowiński, Adam; Romański, Emil; Bieleń, Przemysław; Bednarek, Michał; Puścińska, Elżbieta; Goljan-Geremek, Anna; Pływaczewski, Robert; Śliwinski, Paweł

    2015-01-01

    Office spirometry has been widely used in recent years by general practitioners in primary care setting, thus the need for stricter monitoring of the quality of spirometry has been recognized. A spirometry counseling network of outpatients clinics was created in Poland using portable spirometer Spirotel. The spirometry data were transferred to counseling centre once a week. The tests sent to the counseling centre were analyzed by doctors experienced in the analysis of spirometric data. In justified cases they sent their remarks concerning performed tests to the centres via e-mail. We received 878 records of spirometry tests in total. Data transmission via the telephone was 100% effective. The quality of spirometry tests performed by outpatients clinics was variable. The use of spirometers with data transfer for training purposes seems to be advisable. There is a need to proper face-to-face training of spirometry operators before an implementation of any telemedicine technology.

  12. Quality assurance of spirometry in a population-based study -predictors of good outcome in spirometry testing.

    Science.gov (United States)

    Tan, Wan C; Bourbeau, Jean; O'Donnell, Denis; Aaron, Shawn; Maltais, Francois; Marciniuk, Darcy; Hernandez, Paul; Cowie, Robert; Chapman, Kenneth; Sonia Buist, A; Sin, Don; Mark Fitzgerald, J

    2014-04-01

    The assurance of high-quality spirometry testing remains a challenge. Spirometry training consisted of standardized coaching followed by certification for 35 spirometry-naïve and 9 spirometry-experienced research assistants. Spirometry was performed before and after bronchodilator (BD) in random population samples of 5176 people aged 40 years and older from 9 sites in Canada. using the hand-held EasyOne spirometer (ndd Medical Technologies Inc., Andover, MA, USA). Pulmonary function quality assurance with over reading was conducted centrally in Vancouver: spirograms were reviewed and graded according to ATS/ERS standards with prompt feedback to the technician at each site. Descriptive statistics were calculated for manoeuvre acceptability and repeatability variables. A logistic regression model was constructed for the predictors of spirometry quality success. 95% of test sessions achieved pre-determined quality standards for back extrapolated volume (BEV), time to peak flow (PEFT) and end of test volume (EOTV). The mean forced expiratory time (FET) was 11.2 seconds. Then, 90% and 95% of all manoeuvres had FEV1 and FVC that were repeatable within 150 ml and 200 ml respectively. Test quality was slightly better for post-BD test sessions compared with pre-BD for both groups of research assistants. Independent predictors of acceptable test quality included participant characteristics: female sex, younger age, greater BD responsiveness; but not study site or prior experience in completing spirometry by the technologist. Good quality spirometry tests are attainable in large multicenter epidemiological studies by trained research assistants, irrespective of their prior experience in spirometry.

  13. Variability of the soft excess in the Seyfert I galaxy Mkn 335

    International Nuclear Information System (INIS)

    Turner, T.J.; Pounds, K.A.

    1988-01-01

    The luminous Seyfert 1 galaxy Mkn 335 was observed by EXOSAT on six occasions between 1983 November 5 and 1985 December 24. A previous analysis of the 1984 December 6 observation revealed a two-component spectrum, with a hard power law dominant above ∼ 2 keV on which was superimposed a strong soft X-ray excess in the 0.1-2 keV band of the EXOSAT low-energy (LE) detectors. The hard X-ray component was seen to vary strongly over time-scales of 1-2 hr in this 1984 observation. The more recent observations of Mkn 335, reported here, have shown the soft spectral excess to be a persistent feature, and the continuing presence of rapid variability in the hard X-ray component. An extended observation on 1985 July 21-22 has also revealed a strong variation in the LE band on a time-scale of ∼ 10 hr. This is the first report of distinctive short-term variability in the soft X-ray excess of an AGN, strengthening its proposed identification with the thermal emission from an accretion disc. (author)

  14. Optimal distribution of reactivity excess in a system of reactors operating at a variable loading schedule

    International Nuclear Information System (INIS)

    Bolsunov, A.A.; Zagrebaev, A.M.; Naumov, V.I.

    1979-01-01

    Considered is the task of reactivity excess distribution optimization in the system of reactors for the purpose of minimazing the summary power production losses at the fixed loading schedule. Mathematical formulation of the task is presented. Given are the curves, characterizing the dependence of possible degree of the reactor power drop on reactivity excees for non-stationary Xe poisoning at different nominal density of neutron flux. Analyzing the results, it is concluded that in case, when the reactors differ only in neutron flux density the reactor with lower neutron flux density should be involved in the variable operation schedule first as the poisoning of this reactor will be less, and therefore, the losses of the system power production will be less. It is advisable to reserve the reactivity excess in the reactor with greater power or in the reactor with higher burnup rate. It is stressed that the obtained results of the optimization task solution point out the possibility of obtaining the certain ecomonic effect and permit to correct the requirements on mobility of separate power units at system approach to NPP operation in a variable loading schedule

  15. Telemedical Education: Teaching Spirometry on the Internet.

    Science.gov (United States)

    Lum, Esther H.; Gross, Thomas J.

    1999-01-01

    Describes the development and evaluation of an Internet-based tutorial for teaching spirometry interpretation to nonpulmonologists. Concludes that computer-based tutorials can effectively train off-site practitioners in spirometry interpretation. Contains 23 references. (Author/WRM)

  16. Reference values of inspiratory spirometry for Finnish adults.

    Science.gov (United States)

    Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R

    2018-03-07

    Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.

  17. Excess Weight, Anthropometric Variables and Blood Pressure in Schoolchildren aged 10 to 18 years

    International Nuclear Information System (INIS)

    Schommer, Vânia Ames; Barbiero, Sandra Mari; Cesa, Cláudia Ciceri; Oliveira, Rosemary; Silva, Anelise Damiani; Pellanda, Lucia Campos

    2014-01-01

    The prevalence of hypertension among children and adolescents is estimated to range between 1% and 13%. Excess weight and central obesity are related to blood pressure levels in adults, and may be important in the early pathogenesis of SH when present in childhood. To study the association between anthropometric variables and blood pressure levels in schoolchildren from the 5 th and 8 th grades, and to identify which parameter was more strongly correlated with blood pressure levels. Contemporary cross-sectional study with probabilistic population-based cluster sampling of schoolchildren enrolled from the 5 th to the 8 th grades in public elementary schools of Porto Alegre. Data on familial risk factors and anthropometry were collected. Statistical analysis included correlations and cluster-adjusted confidence intervals. The mean age of participants was 12.57 (± 1.64) years, and 55.2% of them were females. Abnormal blood pressure levels were found in 11.3% of the sample and borderline values, in 16.2%. Among the anthropometric variables analyzed, hip circumference was the one with the strongest correlation with increased blood pressure (r = 0.462, p < 0.001), followed by waist circumference (r = 0.404, p < 0.001) and abdominal skinfold (r = 0.291, p < 0.001). We observed an association of waist circumference and skinfolds with increased blood pressure levels in the schoolchildren of the sample. Therefore, it is of the utmost importance that early measurements of blood pressure, and waist and hip circumferences become a routine in health services in order to prevent this condition

  18. Excess Weight, Anthropometric Variables and Blood Pressure in Schoolchildren aged 10 to 18 years

    Energy Technology Data Exchange (ETDEWEB)

    Schommer, Vânia Ames [Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil); Barbiero, Sandra Mari; Cesa, Cláudia Ciceri; Oliveira, Rosemary [Instituto de Cardiologia/Fundação Universitária de Cardiologia (IC/FUC), Porto Alegre, RS (Brazil); Silva, Anelise Damiani [Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil); Pellanda, Lucia Campos, E-mail: luciapell.pesquisa@cardiologia.org.br [Instituto de Cardiologia/Fundação Universitária de Cardiologia (IC/FUC), Porto Alegre, RS (Brazil); Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil)

    2014-04-15

    The prevalence of hypertension among children and adolescents is estimated to range between 1% and 13%. Excess weight and central obesity are related to blood pressure levels in adults, and may be important in the early pathogenesis of SH when present in childhood. To study the association between anthropometric variables and blood pressure levels in schoolchildren from the 5{sup th} and 8{sup th} grades, and to identify which parameter was more strongly correlated with blood pressure levels. Contemporary cross-sectional study with probabilistic population-based cluster sampling of schoolchildren enrolled from the 5{sup th} to the 8{sup th} grades in public elementary schools of Porto Alegre. Data on familial risk factors and anthropometry were collected. Statistical analysis included correlations and cluster-adjusted confidence intervals. The mean age of participants was 12.57 (± 1.64) years, and 55.2% of them were females. Abnormal blood pressure levels were found in 11.3% of the sample and borderline values, in 16.2%. Among the anthropometric variables analyzed, hip circumference was the one with the strongest correlation with increased blood pressure (r = 0.462, p < 0.001), followed by waist circumference (r = 0.404, p < 0.001) and abdominal skinfold (r = 0.291, p < 0.001). We observed an association of waist circumference and skinfolds with increased blood pressure levels in the schoolchildren of the sample. Therefore, it is of the utmost importance that early measurements of blood pressure, and waist and hip circumferences become a routine in health services in order to prevent this condition.

  19. [Spirometry in the GP-Office].

    Science.gov (United States)

    Gonzalez, Leander; Stolz, Daiana

    2016-02-17

    Spirometry is an important diagnostic tool, which, with correct implementation, detects possible obstructive or restrictive lung diseases. However, it is important to note that only part of the lung function is measured by spirometry. For instance, total lung volume and residual volume, both useful in detecting pulmonary emphysema, are not measured. Therefore, in case of pathological spirometry or suspected restrictive lung disease, further tests such as body plethysmography with diffusion measurement should be carried out.

  20. Influence of socioeconomic and demographic status on spirometry testing in patients initiating medication targeting obstructive lung disease

    DEFF Research Database (Denmark)

    Koefoed, Mette M; Søndergaard, Jens; Christensen, René Depont

    2013-01-01

    a possible association between education, income, labour market affiliation, cohabitation status and having spirometry performed when initiating medication targeting obstructive pulmonary disease. METHODS: We conducted a population-based cohort study. Danish national registers were linked, retrieving data...... on prescriptions, spirometry testing, socioeconomic and demographic variables in all first time users of medication targeting obstructive lung disease in 2008. RESULTS: A total of 37,734 persons were included and approximately half of the cohort had spirometry performed. Among medication users under 65 years...... spirometry performed among men (OR = 0.78, CI = 0.69-0.88). CONCLUSION: Social inequity in spirometry testing among patients initiating medication targeting obstructive lung disease was confirmed in this study. Increased focus on spirometry testing among elderly men living alone, among the unemployed...

  1. Prediction Equations for Spirometry for Children from Northern India.

    Science.gov (United States)

    Chhabra, Sunil K; Kumar, Rajeev; Mittal, Vikas

    2016-09-08

    To develop prediction equations for spirometry for children from northern India using current international guidelines for standardization. Re-analysis of cross-sectional data from a single school. 670 normal children (age 6-17 y; 365 boys) of northern Indian parentage. After screening for normal health, we carried out spirometry with recommended quality assurance according to current guidelines. We developed linear and nonlinear prediction equations using multiple regression analysis. We selected the final models on the basis of the highest coefficient of multiple determination (R2) and statistical validity. Spirometry parameters: FVC, FEV1, PEFR, FEF50, FEF75 and FEF25-75. The equations for the main parameters were as follows: Boys, Ln FVC = -1.687+0.016*height +0.022*age; Ln FEV1 = -1.748+0.015*height+0.031*age. Girls, Ln FVC = -9.989 +(2.018*Ln(height)) + (0.324*Ln(age)); Ln FEV1 = -10.055 +(1.990*Ln(height))+(0.358*Ln(age)). Nonlinear regression yielded substantially greater R2 values compared to linear models except for FEF50 for girls. Height and age were found to be the significant explanatory variables for all parameters on multiple regression with weight making no significant contribution. We developed prediction equations for spirometry for children from northern India. Nonlinear equations were superior to linear equations.

  2. Five tips for good office spirometry

    African Journals Online (AJOL)

    Spirometry is critical for the correct diagnosis of chronic obstructive pulmonary disease (COPD) and is part of the severity classification. It ultimately guides treatment choices. When per forming spirometry on a COPD patient, one expects a flow volume loop to have some degree of obstruction. To obtain and confirm this result ...

  3. A smart spirometry device for asthma diagnosis.

    Science.gov (United States)

    Kassem, A; Hamad, M; El Moucary, C

    2015-08-01

    In this paper an innovative prototype for smart asthma spirometry device to be used by doctors and asthma patients is presented. The novelty in this prototype relies in the fact that it is destined to subtend not only adults but offers an efficient and attractive manner to accommodate children patients as well thus, making it efficient for doctors, patients and parents to detect and monitor such intricate cases at stages as early as six years old. Moreover, the apparatus used enables us to integrate a vital parameter representing the Forced Expiratory Volume to the final diagnosis. Besides, the presented device will automatically diagnose those patients, assess their asthma condition, and schedule their medication process without excessive visits to medical centers whilst providing doctors with accurate and pertinent and comprehensive medical data in a chronological fashion. Zooming into under the hood of the device, a fully reliable hardware digital system lies along with a flowmeter detector and a Bluetooth emitter to interface with a user-friendly GUI-based application installed on smartphones which incorporates appealing animated graphics to encourage children to take the test. Furthermore, the device offers the capability of storing chronological data and a relevant resourceful display for accurate tracking of patients' medical record, the evolvement of their asthma condition, and the administered medication. Finally, the entire device is aligned with the medical requirements as per doctors' and telemedicine specialists' recommendations; the experiments carried out demonstrated the effectiveness and sustainable use of such device.

  4. The association between incentive spirometry performance and pain in postoperative thoracic epidural analgesia.

    Science.gov (United States)

    Harris, David J; Hilliard, Paul E; Jewell, Elizabeth S; Brummett, Chad M

    2015-01-01

    Effective use of postoperative incentive spirometry improves patient outcomes but is limited by pain after thoracic and upper abdominal surgery. Thoracic epidurals are frequently used to provide analgesia and attenuate postoperative pulmonary dysfunction. We hypothesized that, in patients with thoracic epidurals for thoracic and abdominal surgery, high pain scores would be associated with poorer incentive spirometry performance, even when accounting for other variables. Retrospective study of 468 patients who underwent upper abdominal or thoracic surgery using postoperative thoracic epidural analgesia between June 1, 2009, and August 31, 2013, at a single tertiary academic center. The association between incentive spirometry performance and pain was assessed as the primary outcome. Other independent predictors of incentive spirometry performance were also identified. Postoperative incentive spirometry performance was found to be inversely proportional to pain score, which correlated significantly stronger with deep breathing pain compared with pain at rest (-0.33 vs -0.14 on postoperative day 1; -0.23 vs -0.12 on postoperative day 2). Pain with deep breathing was independently associated with poorer incentive spirometry performance in the multivariable linear regression model (P spirometry performance could be used as another indicator of thoracic epidural efficacy. This may be particularly useful in patients reporting high pain scores postoperatively.

  5. Accuracy of near-patient vs. inbuilt spirometry for monitoring tidal volumes in an in-vitro paediatric lung model.

    Science.gov (United States)

    Morgenroth, S; Thomas, J; Cannizzaro, V; Weiss, M; Schmidt, A R

    2018-03-01

    Spirometric monitoring provides precise measurement and delivery of tidal volumes within a narrow range, which is essential for lung-protective strategies that aim to reduce morbidity and mortality in mechanically-ventilated patients. Conventional anaesthesia ventilators include inbuilt spirometry to monitor inspiratory and expiratory tidal volumes. The GE Aisys CS 2 anaesthesia ventilator allows additional near-patient spirometry via a sensor interposed between the proximal end of the tracheal tube and the respiratory tubing. Near-patient and inbuilt spirometry of two different GE Aisys CS 2 anaesthesia ventilators were compared in an in-vitro study. Assessments were made of accuracy and variability in inspiratory and expiratory tidal volume measurements during ventilation of six simulated paediatric lung models using the ASL 5000 test lung. A total of 9240 breaths were recorded and analysed. Differences between inspiratory tidal volumes measured with near-patient and inbuilt spirometry were most significant in the newborn setting (p tidal volume measurements with near-patient spirometry were consistently more accurate than with inbuilt spirometry for all lung models (p tidal volumes decreased with increasing tidal volumes, and was smaller with near-patient than with inbuilt spirometry. The variability in measured tidal volumes was higher during expiration, especially with inbuilt spirometry. In conclusion, the present in-vitro study shows that measurements with near-patient spirometry are more accurate and less variable than with inbuilt spirometry. Differences between measurement methods were most significant in the smallest patients. We therefore recommend near-patient spirometry, especially for neonatal and paediatric patients. © 2018 The Association of Anaesthetists of Great Britain and Ireland.

  6. Spirometry-related pain and distress in adolescents and young adults with cystic fibrosis: the role of acceptance.

    Science.gov (United States)

    Casier, Annabelle; Goubert, Liesbet; Vervoort, Tine; Theunis, Marleen; Huse, Danielle; De Baets, Frans; Matthys, Dirk; Crombez, Geert

    2013-01-01

    To investigate the occurrence of spirometry-related pain and distress in adolescents and young adults with cystic fibrosis (CF), and to investigate the role of acceptance of illness in spirometry-related pain and distress. A total of 36 adolescents and young adults with CF (12 to 22 years of age) completed a questionnaire assessing acceptance of illness. Spirometry-related distress was assessed using self-report (ie, anxiety⁄worry about the procedure) and physiological outcomes (ie, heart rate and heart rate variability) before spirometry. Spirometry-related pain was assessed using self-report (ie, expected pain and pain-related thoughts). Self-reported distress and pain during spirometry were also assessed. Eighty-nine per cent of subjects reported distress before spirometry, 67% experienced distress during spirometry, 28% expected pain during spirometry and 22% actually experienced pain. Interestingly, partial correlations revealed that more acceptance was related to less expected pain and pain-related thoughts. Acceptance, however, was unrelated to distress, anxiety and pain during spirometry. The present study suggests that a non-negligible number of adolescents and young adults with CF experience pain and distress during spirometry. Furthermore, results indicate that acceptance may play a protective role in the more indirect consequences of CF such as expected pain and pain-related thoughts during medical procedures. Acceptance, however, was not related to distress before and during spirometry, nor to experienced pain. These findings contribute to the increasing evidence that acceptance may play a protective role in managing the consequences of living with CF.

  7. Prediction equations for spirometry in adults from northern India.

    Science.gov (United States)

    Chhabra, S K; Kumar, R; Gupta, U; Rahman, M; Dash, D J

    2014-01-01

    Most of the Indian studies on prediction equations for spirometry in adults are several decades old and may have lost their utility as these were carried out with equipment and standardisation protocols that have since changed. Their validity is further questionable as the lung health of the population is likely to have changed over time. To develop prediction equations for spirometry in adults of north Indian origin using the 2005 American Thoracic Society/European Respiratory Society (ATS/ERS) recommendations on standardisation. Normal healthy non-smoker subjects, both males and females, aged 18 years and above underwent spirometry using a non-heated Fleisch Pneumotach spirometer calibrated daily. The dataset was randomly divided into training (70%) and test (30%) sets and the former was used to develop the equations. These were validated on the test data set. Prediction equations were developed separately for males and females for forced vital capacity (FVC), forced expiratory volume in first second (FEV1), FEV1/FVC ratio, and instantaneous expiratory flow rates using multiple linear regression procedure with different transformations of dependent and/or independent variables to achieve the best-fitting models for the data. The equations were compared with the previous ones developed in the same population in the 1960s. In all, 685 (489 males, 196 females) subjects performed spirometry that was technically acceptable and repeatable. All the spirometry parameters were significantly higher among males except the FEV1/FVC ratio that was significantly higher in females. Overall, age had a negative relationship with the spirometry parameters while height was positively correlated with each, except for the FEV1/FVC ratio that was related only to age. Weight was included in the models for FVC, forced expiratory flow (FEF75) and FEV1/FVC ratio in males, but its contribution was very small. Standard errors of estimate were provided to enable calculation of the lower

  8. [Spirometry - basic examination of the lung function].

    Science.gov (United States)

    Kociánová, Jana

    Spirometry is one of the basic internal examination methods, similarly as e.g. blood pressure measurement or ECG recording. It is used to detect or assess the extent of ventilatory disorders. Indications include respiratory symptoms or laboratory anomalies, smoking, inhalation risks and more. Its performance and evaluation should be among the basic skills of pulmonologists, internists, alergologists, pediatricians and sports physicians. The results essentially influence the correct diagnosing and treatment method. Therefore spirometry must be performed under standardized conditions and accurately and clearly assessed to enable answering clinical questions.Key words: acceptability - calibration - contraindication - evaluation - indication - parameters - spirometry - standardization.

  9. Spirometry utilisation among Danish adults initiating medication targeting obstructive lung disease.

    Science.gov (United States)

    Koefoed, Mette Marie

    2015-02-01

    status were associated with spirometry testing (Studies I &II) - To assess if general practice characteristics were associated with spirometry testing (Study III)   Register-based observational studies on first time users of medication targeting obstructive lung disease among adults over 18 years of age in 2008. The patient cohort was identified in the Danish National Prescription Register where all redeemed prescriptions for medication targeting obstructive lung disease are registered. All spirometry tests provided to the patient cohort in the time period 2007-2010 were extracted from the Danish National Health Service Register and the Danish National Patient Register and we assessed if patients had a spirometry registered in an 18- month time period counting from 6 months before to 12 months after their first redemption of medication. We linked socioeconomic and demographic patient variables and variables on practice characteristics from National registers to assess their association with patients having spirometry performed.   A total of 40,969 adults initiated medication targeting obstructive lung medication in 2008 in Denmark. The mean age of the cohort was 55.6 years (SD18.7) and approximately half of the mediations users had spirometry test performed. Initiating several types of medication targeting obstructive lung disease within the first year and redeeming medication repeatedly increased the odds of having spirometry performed. Women and patients in the oldest age categories had reduced odds of having spirometry performed. Being unemployed reduced the odds for spirometry testing among adults less than 65 years of age. Also, among the elderly (>65 years) living alone reduced the odds for spirometry testing; however this was only statistically significant among men. Some practice characteristics also influenced the odds for spirometry testing. Patients in partnership practices had higher odds for spirometry testing. Among singlehanded practices higher odds for

  10. Excessive exercise among adolescents with eating disorders: examination of psychological and demographic variables.

    Science.gov (United States)

    Renz, Jessica A; Fisher, Martin; Vidair, Hilary B; Hirsch, Dina; Malizio, Joan; Barger, Hamutal; Fornari, Victor

    2017-08-29

    Background While a large number of patients with eating disorders (EDs) engage in excessive exercise (EE), both for weight control and mood regulation, there has been minimal research evaluating the relationship between EE and demographic and psychological factors, especially in adolescent patients. Purpose The goals of this study were to identify the occurrence of EE compared to other ED behaviors and to develop a regression model examining psychological, behavioral and demographic predictors of EE among adolescents with EDs. Methods Demographic and clinical information was determined for 217 adolescent patients in several levels of care (126 outpatient, 61 day program, 28 inpatient) with diagnoses of anorexia nervosa (AN) (24.9%), bulimia nervosa (BN) (25.8%), and eating disorder not otherwise specified (EDNOS) (49.3%). These patients presented to a large ED program and completed a series of questionnaires on admission to the program. Descriptive statistics, t-tests, chi-square analyses and multiple logistic regression were utilized to describe the population of adolescent patients and develop the model for predicting EE. Results Forty-seven percent of patients indicated they participated in EE in the past 4 weeks, compared to 32% for binge eating, 35% for vomiting and 15% for laxative use; 42% of patients with anorexia nervosa participated in EE, compared to 54% with bulimia nervosa and 49% with EDNOS. The regression model that was developed to predict EE, which included factors of depression, anxiety, dietary restraint, age, body mass index (BMI), diagnosis and level of care, correctly classified EE in 71.5% of cases. Dietary restraint and BMI were the two factors found to be significantly associated with EE. Conclusions Forty-seven percent of adolescent patients presenting for treatment of an ED reported participating in EE. This was larger than the numbers of patients reporting other ED behaviors that are commonly assessed, indicating the need for

  11. Excess Vitamin Intake before Starvation does not Affect Body Mass, Organ Mass, or Blood Variables but Affects Urinary Excretion of Riboflavin in Starving Rats.

    Science.gov (United States)

    Moriya, Aya; Fukuwatari, Tsutomu; Shibata, Katsumi

    2013-01-01

    B-vitamins are important for producing energy from amino acids, fatty acids, and glucose. The aim of this study was to elucidate the effects of excess vitamin intake before starvation on body mass, organ mass, blood, and biological variables as well as on urinary excretion of riboflavin in rats. Adult rats were fed two types of diets, one with a low vitamin content (minimum vitamin diet for optimum growth) and one with a sufficient amount of vitamins (excess vitamin diet). Body mass, organ mass, and blood variables were not affected by excess vitamin intake before starvation. Interestingly, urinary riboflavin excretion showed a different pattern. Urine riboflavin in the excess vitamin intake group declined gradually during starvation, whereas it increased in the low vitamin intake group. Excess vitamin intake before starvation does not affect body mass, organ mass, or blood variables but does affect the urinary excretion of riboflavin in starving rats.

  12. Excess Vitamin Intake before Starvation does not Affect Body Mass, Organ Mass, or Blood Variables but Affects Urinary Excretion of Riboflavin in Starving Rats

    Directory of Open Access Journals (Sweden)

    Aya Moriya

    2013-01-01

    Full Text Available B-vitamins are important for producing energy from amino acids, fatty acids, and glucose. The aim of this study was to elucidate the effects of excess vitamin intake before starvation on body mass, organ mass, blood, and biological variables as well as on urinary excretion of riboflavin in rats. Adult rats were fed two types of diets, one with a low vitamin content (minimum vitamin diet for optimum growth and one with a sufficient amount of vitamins (excess vitamin diet. Body mass, organ mass, and blood variables were not affected by excess vitamin intake before starvation. Interestingly, urinary riboflavin excretion showed a different pattern. Urine riboflavin in the excess vitamin intake group declined gradually during starvation, whereas it increased in the low vitamin intake group. Excess vitamin intake before starvation does not affect body mass, organ mass, or blood variables but does affect the urinary excretion of riboflavin in starving rats.

  13. Feasibility of spirometry testing in preschool children.

    Science.gov (United States)

    Kampschmidt, Jordan C; Brooks, Edward G; Cherry, Debra C; Guajardo, Jesus R; Wood, Pamela R

    2016-03-01

    The primary purpose of this study was to evaluate the feasibility of obtaining acceptable and reproducible spirometry data in preschool aged children (3-5 years) by technicians without prior experience with spirometry. Two technicians were trained to perform spirometry testing (ndd Easy on-PC) and to administer standardized questionnaires. Preschool aged children were enrolled from two Head Start centers and a local primary care clinic. Subjects were trained in proper spirometry technique and tested until at least two acceptable efforts were obtained or the subject no longer produced acceptable efforts. 200 subjects were enrolled: mean age 4.0 years (± 0.7 SD); age distribution: 51 (25.5%) 3 years old, 103 (51.5%) 4 years old, and 46 (23%) 5 years old. Fifty-six percent male and 75% Hispanic. One hundred thirty (65%) subjects produced at least one acceptable effort on their first visit: 23 (45%) for 3 years old, 67 (65%) for 4 years old, and 40 (87%) for 5 years old. The number of acceptable efforts correlated with age (r = 0.29, P spirometry results from the preschool aged children; the number of acceptable efforts correlated significantly with age. © 2015 Wiley Periodicals, Inc.

  14. A Survey of X-Ray Variability in Seyfert 1 Galaxies with XMM-Newton to study the soft excess and the broad Fe lines

    Science.gov (United States)

    Ponti, Gabriele

    The nature of the soft excess and the presence of the broad Fe lines is still nowadays highly debated because the different absorption/emission models are degenerate. Spectral variability studies have the potential to break this degeneracy. I will present the results of a spectral variability RMS survey of the 36 brightest type 1 Seyfert galaxies observed by XMM-Newton for more than 30 ks. More than 80 as already measured, on longer timescales, with RXTE (Markowitz et al. 2004). About half of the sample show lower variability in the soft energy band, indicating that the emission from the soft excess is more stable than the one of the continuum. While the other sources show a soft excess that is as variable as the continuum. About half of the sample do not show an excess of variability where the warm absorber component imprints its stronger features, suggesting that for these sources the soft excess is not produced by a relativistic absorbing wind. In a few bright and well exposed sources it has been possible to measure an excess of variability at the energy of the broad component of the Fe K line, in agreement with the broad emission line interpretation. For the sources where more than one observation was available the stability of the shape of the RMS spectrum has been investigated. Moreover, it will be presented the results of the computation of the excess variance of all the radio quiet type 1 AGN of the XMM-Newton database. The relations between variability, black hole mass, accretion rate and luminosity are investigated and their scatter measured.

  15. [Quality scale for preschool spirometry interpretation].

    Science.gov (United States)

    Gatto, Francisca; Bedregal, Paula; Ubilla, Carlos; Barrientos, Hortensia; Caussade, Solange

    2017-02-01

    Since 2007, there are international guidelines for implementation and interpretation of spirometry in preschool children. A percentage of these patients cannot obtain maneuvers that meet all eligibility criteria. The objective of this study was to develop a quality scale for interpreting these partially acceptable spirometry. Delphi methodology was used, which allows to reach consensus among experts analyzing a defined problem. We invited to participate pediatric pneumologists dedicated to lung function and who participated actively in scientific specialty societies in Chile. Successive rounds were conducted with questionnaires about criteria used to assess spirometry in preschool children. These criteria define the acceptability of spirometric maneuvers according to international guidelines. Proposed quality grades were “very good”, “good”, “fair” and “bad”. Thirteen of the 15 invited experts accepted our invitation. In the first round 9 disagreed with the degree of “regular” quality. In the second round this was removed and 11 experts answered, 9 of them agreed with the use of this new version. The most contentious criterion was the end of expiration. Most experts agreed with the final scale, using “very good”, “good” and “bad” judgments. This would help to improve the performance of spirometry in children between 2 and 5 years.

  16. Spirometry reference values in the Brazilian population.

    Science.gov (United States)

    Rufino, R; Costa, C H; Lopes, A J; Maiworm, A I; Maynard, K; Silva, L M R A; Dias, R M

    2017-03-02

    The aim of the present study was to provide new spirometry reference equations in a sample of the Brazilian population for the following parameters: forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/FVC ratio, peak of expiratory flow (PEF), forced expiratory flow at 50% (FEF50%), 75% average vital capacity (FEF25-75%), and average forced expiratory flow time (FEFT). This was a prospective study using results from chest radiographs, electrocardiograms, and questionnaires to investigate the participants' respiratory symptoms, sedentarism, and comorbidities (Charlson comorbidity index). From December 2010 to July 2014, individuals were randomly selected from various locations in the state of Rio de Janeiro. All individuals were examined by a single technician in the morning at the laboratory, and performed the spirometry with the same spirometer. Spirometry values were tabulated for the creation of three equation models: linear regression, logarithmic regression, and logarithms through a method that incorporates the lambda, median, and coefficient of variation (LMS method). Initially, 7003 individuals from both genders were contacted, and 454 were recruited. The data from the new equations were compared with one Brazilian and eight international equations, resulting in a high correlation (r>0.9). The values derived from the LMS method and linear regression were very similar (P>0.5), and both could be used to acquire the reference values for Brazilian spirometry. Data derived from the equations of this study were different from the current Brazilian equation, which could be justified by the different method used.

  17. The European Respiratory Society spirometry tent

    DEFF Research Database (Denmark)

    Maio, Sara; Sherrill, Duane L; MacNee, William

    2012-01-01

    In order to raise public awareness of the importance of early detection of airway obstruction and to enable many people who had not been tested previously to have their lung function measured, the European Lung Foundation and the European Respiratory Society (ERS) organised a spirometry testing...

  18. Spirometry quality in adults with very severe lung function impairment.

    Science.gov (United States)

    Torre-Bouscoulet, Luis; Velázquez-Uncal, Mónica; García-Torrentera, Rogelio; Gochicoa-Rangel, Laura; Fernández-Plata, Rosario; Enright, Paul; Pérez-Padilla, Rogelio

    2015-05-01

    Some technologists worry that patients with very severe lung disease are unable to complete several spirometry maneuvers, which require considerable effort. We retrospectively selected all spirometry tests with an FEV1 30,000 subjects tested during the 3-y period) had adequate quality spirometry. Subjects with airway obstruction were less likely to meet FVC repeatability goals. A poor spirometry quality grade was associated with a very low FVC and a low body mass index, but not older age. Severe lung disease should not be used as an excuse for not meeting spirometry quality goals. Copyright © 2015 by Daedalus Enterprises.

  19. Spirometry use in children hospitalized with asthma.

    Science.gov (United States)

    Tan, Chee Chun; McDowell, Karen M; Fenchel, Matthew; Szczesniak, Rhonda; Kercsmar, Carolyn M

    2014-05-01

    Asthma is the most common chronic disorder of childhood and continues to be a leading cause of pediatric hospital admission. The National Asthma Education and Prevention Program (NAEPP) recommends that spirometry be obtained for asthma patients upon hospital admission, after bronchodilation during the acute phase of asthma symptoms, and at least one additional time before discharge from the hospital. The objectives of this study were to describe the use of spirometry in children hospitalized with asthma and to determine association of pulmonary function with future exacerbations. A retrospective cohort study design was utilized involving review of medical records of children ≥5 years old admitted with asthma to Cincinnati Children's Hospital Medical Center from September 1, 2009 to March 31, 2011. Hospitalization or emergency department (ED) visits were identified by the ICD-9-CM codes of having either a primary diagnosis of asthma (493) or a respiratory illness (460-496) plus a secondary diagnosis of asthma. Asthma re-exacerbation was defined as either having an ED visit or hospitalization for asthma that occurred within 3 months after the index hospitalization. All spirometries were performed in a pediatric pulmonary function laboratory. Among 1,037 admissions included in this study, 89 (8.6%) had spirometry that was recommended by a consulting asthma specialist and usually performed on the day of discharge. Spirometries for forty-five of these patients (54.9%) met all acceptability and repeatability criteria of the American Thoracic Society. Patients who performed acceptable spirometry were significantly older (12.4 ± 3.8 vs. 10.7 ± 3.0 years; P = 0.041). The average forced expiratory volume in the first second (FEV1 ) was 84.4 ± 19.7% predicted; forced vital capacity (FVC) was 98.1 ± 16.0% predicted; FEV1 /FVC was 74.6 ± 9.6%; forced expiratory flow at 25-75% (FEF25-75 ) was 61.2 ± 30.1% predicted. Ten patients (22%) who

  20. Spirometry Changes in Cold Climatic Conditions of Antarctica.

    Science.gov (United States)

    Udaya, Iyamanda B; Laxmi, Chettangada C; Abhishekh, Hulegar A; Raju, Trichur R; Sathyaprabha, Talakad N

    2015-01-01

    Pulmonary function is one of the important physiological measures that is known to be affected during the changes in the altitude. There is dearth of literature on changes in the pulmonary function variables in the cold climate conditions of Antarctica. We carried out spirometry before, during and after one year stay at Antarctica in members of the Indian expedition. Spirometry was carried out on 23 members of the XXVI Indian Scientific Expedition to Antarctica at baseline, after six months of expedition and at the end of one year, using standard guidelines. The tests were carried out indoor in temperature controlled laboratory. The pulmonary function test parameters did not vary across the period. Although, both forced vital capacity (FVC) and forced expiratory volume in first second (FEV1) showed a decreasing trend but did not attain any statistical significance. However, peak expiratory flow (PEFR) rate was reduced significantly. Our study did not show consistently significant change in the pulmonary function parameters in the members of the Indian Antarctic expedition.

  1. Reference values of spirometry for Finnish adults.

    Science.gov (United States)

    Kainu, A; Timonen, K L; Toikka, J; Qaiser, B; Pitkäniemi, J; Kotaniemi, J T; Lindqvist, A; Vanninen, E; Länsimies, E; Sovijärvi, A R A

    2016-09-01

    Diagnostic assessment of lung function necessitates up-to-date reference values. The aim of this study was to estimate reference values for spirometry for the Finnish population between 18 and 80 years and to compare them with the existing Finnish, European and the recently published global GLI2012 reference values. Spirometry was performed for 1380 adults in the population-based FinEsS studies and for 662 healthy non-smoking volunteer adults. Detailed predefined questionnaire screening of diseases and symptoms, and quality control of spirometry yielded a sample of 1000 native Finns (387 men) healthy non-smokers aged 18-83 years. Sex-specific reference values, which are estimated using the GAMLSS method and adjusted for age and height, are provided. The predicted values for lung volumes are larger than those obtained by GLI2012 prediction for the Caucasian subgroup for forced vital capacity (FVC) by an average 6·2% and 5·1% and forced expiratory volume in 1 s (FEV1) by an average 4·2% and 3·0% in men and women, respectively. GLI2012 slightly overestimated the ratio FEV1/FVC with an age-dependent trend. Most reference equations from other European countries, with the exception of the Swiss SAPALDIA study, showed an underestimation of FVC and FEV1 to varying degrees, and a slight overestimation of FEV1/FVC. This study offers up-to-date reference values of spirometry for native Finns with a wide age range. The GLI2012 predictions seem not to be suitable for clinical use for native Finns due to underestimation of lung volumes. © 2015 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd on behalf of Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  2. Spirometry reference values in the Brazilian population

    Directory of Open Access Journals (Sweden)

    R. Rufino

    Full Text Available The aim of the present study was to provide new spirometry reference equations in a sample of the Brazilian population for the following parameters: forced vital capacity (FVC, forced expiratory volume in 1 second (FEV1, FEV1/FVC ratio, peak of expiratory flow (PEF, forced expiratory flow at 50% (FEF50%, 75% average vital capacity (FEF25-75%, and average forced expiratory flow time (FEFT. This was a prospective study using results from chest radiographs, electrocardiograms, and questionnaires to investigate the participants' respiratory symptoms, sedentarism, and comorbidities (Charlson comorbidity index. From December 2010 to July 2014, individuals were randomly selected from various locations in the state of Rio de Janeiro. All individuals were examined by a single technician in the morning at the laboratory, and performed the spirometry with the same spirometer. Spirometry values were tabulated for the creation of three equation models: linear regression, logarithmic regression, and logarithms through a method that incorporates the lambda, median, and coefficient of variation (LMS method. Initially, 7003 individuals from both genders were contacted, and 454 were recruited. The data from the new equations were compared with one Brazilian and eight international equations, resulting in a high correlation (r>0.9. The values derived from the LMS method and linear regression were very similar (P>0.5, and both could be used to acquire the reference values for Brazilian spirometry. Data derived from the equations of this study were different from the current Brazilian equation, which could be justified by the different method used.

  3. Influence of socioeconomic and demographic status on spirometry testing in patients initiating medication targeting obstructive lung disease: a population-based cohort study

    Science.gov (United States)

    2013-01-01

    Background Socioeconomic status is known to influence the prevalence, severity and mortality of obstructive lung diseases, but it is uncertain whether it affects the use of diagnostic spirometry in patients initiating treatment for these conditions. The objective of this paper was to examine a possible association between education, income, labour market affiliation, cohabitation status and having spirometry performed when initiating medication targeting obstructive pulmonary disease. Methods We conducted a population-based cohort study. Danish national registers were linked, retrieving data on prescriptions, spirometry testing, socioeconomic and demographic variables in all first time users of medication targeting obstructive lung disease in 2008. Results A total of 37,734 persons were included and approximately half of the cohort had spirometry performed. Among medication users under 65 years of age, being unemployed was significantly associated with reduced odds of having spirometry performed, the strongest association was seen in men (OR = 0.82, CI = 0.73-0.91). Medium income was associated with increased odds of having spirometry performed in men (OR = 1.18, CI = 1.06-1.30) and high educational level (>12 years) was associated with reduced odds of having spirometry performed in women (OR = 0.86, CI = 0.78-0.94). Cohabitation status was not associated with having spirometry performed. Among medication users over 65 years of age, living alone was associated with reduced odds of having spirometry performed among men (OR = 0.78, CI = 0.69-0.88). Conclusion Social inequity in spirometry testing among patients initiating medication targeting obstructive lung disease was confirmed in this study. Increased focus on spirometry testing among elderly men living alone, among the unemployed and among women with higher education is required when initiating medication. PMID:23768408

  4. Spirometry in elderly laryngectomized patients: A feasibility study.

    Science.gov (United States)

    Izzo, Alessandro; Perrotta, Fabio; Cennamo, Antonio; Cerqua, Francesco Saverio; Rinaldi, Luca; Mazzella, Antonio; Grella, Edoardo; Tranfa, Carmelindo; Bianco, Andrea; Stefanelli, Francesco; Mazzarella, Gennaro

    2016-09-01

    Laryngeal cancer is the second most common respiratory neoplasm after lung cancer. Laryngectomy is a well established treatment for larynx cancers which involve relevant anatomic alterations. Spirometry is an essential investigation tool for diagnosis and severity of respiratory diseases, difficult to perform in laryngectomees. 43 consecutive laryngectomized patients were enrolled from July 2014 to March 2015. Patients fulfilling inclusion criteria underwent spirometry at baseline assessment and after two days. During the examination, the spirometer was placed directly on the stoma of the patient, through mouthpiece "Spirometry Filter 74". At baseline, 26 eligible laryngectomees correctly performed the spirometry test with mouthpiece adhering to the stoma; 4 patients refused to perform the second spirometry after 2 days. The feasibility of spirometry examination in these patients was 100% despite difficulties in the execution of the test. The Pearson coefficient of reproducibility for FEV1, FVC and Tiffeneau Index was, respectively, 0.98, 0.94 and 0.77. Spirometry in laryngectomee patients is a feasible procedure for assessment of respiratory function; despite technical difficulties in the execution of the test, our results underline the reproducibility and repeatability of the spirometry. In conclusion, when performed within dedicated respiratory pathophysiology unit, spirometry is a reliable tool in the assessment and follow up of laryngectomees. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  5. The use of spirometry in a primary care setting

    OpenAIRE

    Blain, Elizabeth A; Craig, Timothy J

    2009-01-01

    Elizabeth A Blain, Timothy J CraigPenn State Hershey Medical Center, Hershey, PA, USAObjective: To determine the use of spirometry in family practice, internal medicine, and pediatric outpatient settings.Methods: Data were collected from 45 outpatient offices in the central Pennsylvania area via phone survey that asked a set of four questions: 1) Do you have spirometry in your office? 2) Do you use spirometry for asthma patients? 3) In what situation do you use spirometry for? 4) Do you use s...

  6. Excess Vitamin Intake before Starvation does not Affect Body Mass, Organ Mass, or Blood Variables but Affects Urinary Excretion of Riboflavin in Starving Rats

    OpenAIRE

    Moriya, Aya; Fukuwatari, Tsutomu; Shibata, Katsumi

    2013-01-01

    B-vitamins are important for producing energy from amino acids, fatty acids, and glucose. The aim of this study was to elucidate the effects of excess vitamin intake before starvation on body mass, organ mass, blood, and biological variables as well as on urinary excretion of riboflavin in rats. Adult rats were fed two types of diets, one with a low vitamin content (minimum vitamin diet for optimum growth) and one with a sufficient amount of vitamins (excess vitamin diet). Body mass, organ ma...

  7. Spirometry, Static Lung Volumes, and Diffusing Capacity.

    Science.gov (United States)

    Vaz Fragoso, Carlos A; Cain, Hilary C; Casaburi, Richard; Lee, Patty J; Iannone, Lynne; Leo-Summers, Linda S; Van Ness, Peter H

    2017-09-01

    Spirometric Z-scores from the Global Lung Initiative (GLI) rigorously account for age-related changes in lung function and are thus age-appropriate when establishing spirometric impairments, including a restrictive pattern and air-flow obstruction. However, GLI-defined spirometric impairments have not yet been evaluated regarding associations with static lung volumes (total lung capacity [TLC], functional residual capacity [FRC], and residual volume [RV]) and gas exchange (diffusing capacity). We performed a retrospective review of pulmonary function tests in subjects ≥40 y old (mean age 64.6 y), including pre-bronchodilator measures for: spirometry ( n = 2,586), static lung volumes by helium dilution with inspiratory capacity maneuver ( n = 2,586), and hemoglobin-adjusted single-breath diffusing capacity ( n = 2,508). Using multivariable linear regression, adjusted least-squares means (adj LS Means) were calculated for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity. The adj LS Means were expressed with and without height-cubed standardization and stratified by GLI-defined spirometry, including normal ( n = 1,251), restrictive pattern ( n = 663), and air-flow obstruction (mild, [ n = 128]; moderate, [ n = 150]; and severe, [ n = 394]). Relative to normal spirometry, restrictive-pattern had lower adj LS Means for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity ( P ≤ .001). Conversely, relative to normal spirometry, mild, moderate, and severe air-flow obstruction had higher adj LS Means for FRC and RV ( P < .001). However, only mild and moderate air-flow obstruction had higher adj LS Means for TLC ( P < .001), while only moderate and severe air-flow obstruction had higher adj LS Means for RV/TLC ( P < .001) and lower adj LS Means for hemoglobin-adjusted single-breath diffusing capacity ( P < .001). Notably, TLC (calculated as FRC + inspiratory capacity) was not increased in severe air-flow obstruction ( P ≥ .11

  8. Correlation and Agreement of Handheld Spirometry with Laboratory Spirometry in Allogeneic Hematopoietic Cell Transplant Recipients.

    Science.gov (United States)

    Cheng, Guang-Shing; Campbell, Angela P; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M; Englund, Janet A; Chien, Jason W; Boeckh, Michael

    2016-05-01

    Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplant (HCT) recipients who are at increased risk for late noninfectious pulmonary complications, including bronchiolitis obliterans syndrome. We evaluated the use of handheld spirometry in this population. Allogeneic HCT recipients enrolled in a single-center observational trial performed weekly spirometry with a handheld spirometer for 1 year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: before transplantation, at day 80 after transplantation, and at 1 year after transplantation. Correlation between the 2 methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. A total of 437 subjects had evaluable pulmonary function tests. Correlation for forced expiratory volume in 1 second (FEV1) was r = .954 (P spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. Copyright © 2016 American Society for Blood and Marrow Transplantation. All rights reserved.

  9. X-ray/UV variability and the origin of soft X-ray excess emission from II Zw 177

    Science.gov (United States)

    Pal, Main

    We study a detailed broad-band X-ray/UV emission from the narrow line Seyfert 1 galaxy II Zw 177 based on two XMM-Newton and single Swift/XRT observations. Both XMM-Newton observations show the soft X-ray excess emission below 2 keV when the best-fit 2 - 10 keV power law is extrapolated down to 0.3 keV. We find the blurred reflection from an ionized accretion disc and Comptonized disc emission both describe the observed soft excess well. We find a remarkable trend of decreasing UV flux with increasing soft X-ray excess and power law emission. We suggest that this could be due to that the external edge of corona hide a fraction of accretion disk. Co-Author: Prof. Gulab C. Dewangan (IUCAA), Prof. Ranjeev Misra (IUCAA), Pramod Kumar (Nanded university)

  10. Factors associated with abnormal spirometry among HIV-infected individuals.

    Science.gov (United States)

    Drummond, M Bradley; Huang, Laurence; Diaz, Philip T; Kirk, Gregory D; Kleerup, Eric C; Morris, Alison; Rom, William; Weiden, Michael D; Zhao, Enxu; Thompson, Bruce; Crothers, Kristina

    2015-08-24

    HIV-infected individuals are susceptible to development of chronic lung diseases, but little is known regarding the prevalence and risk factors associated with different spirometric abnormalities in this population. We sought to determine the prevalence, risk factors and performance characteristics of risk factors for spirometric abnormalities among HIV-infected individuals. Cross-sectional cohort study. We analyzed cross-sectional US data from the NHLBI-funded Lung-HIV consortium - a multicenter observational study of heterogeneous groups of HIV-infected participants in diverse geographic sites. Logistic regression analysis was performed to determine factors statistically significantly associated with spirometry patterns. A total of 908 HIV-infected individuals were included. The median age of the cohort was 50 years, 78% were men and 68% current smokers. An abnormal spirometry pattern was present in 37% of the cohort: 27% had obstructed and 10% had restricted spirometry patterns. Overall, age, smoking status and intensity, history of Pneumocystis infection, asthma diagnosis and presence of respiratory symptoms were independently associated with an abnormal spirometry pattern. Regardless of the presence of respiratory symptoms, five HIV-infected participants would need to be screened with spirometry to diagnose two individuals with any abnormal spirometry pattern. Nearly 40% of a diverse US cohort of HIV-infected individuals had an abnormal spirometry pattern. Specific characteristics including age, smoking status, respiratory infection history and respiratory symptoms can identify those at risk for abnormal spirometry. The high prevalence of abnormal spirometry and the poor predictive capability of respiratory symptoms to identify abnormal spirometry should prompt clinicians to consider screening spirometry in HIV-infected populations.

  11. The standard of spirometry in the RSA | Basson | South African ...

    African Journals Online (AJOL)

    Standards for high-quality lung function testing have not yet been formally adopted in the RSA, despite the increase in the performance of spirometry. A study was undertaken to determine the standard of spirometry in clinical practice in this country. Forty-five spirometer users agreed to participate. Responses to a ...

  12. Quality of routine spirometry tests in Dutch general practices.

    NARCIS (Netherlands)

    Schermer, T.R.J.; Crockett, A.J.; Poels, P.J.P.; Dijke, J.J. van; Akkermans, R.P.; Vlek, H.F.; Pieters, W.R.

    2009-01-01

    BACKGROUND: Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care. AIM: To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics. DESIGN OF STUDY: Analysis

  13. Inter-regional changes in the performance and interpretation of spirometry in Spain: 3E study.

    Science.gov (United States)

    López-Campos, José Luis; Soriano, Joan B; Calle, Myriam

    2014-11-01

    This report shows the results of a nation-wide survey on spirometry to assess regional differences. Observational cross-sectional study conducted by means of a telephone survey in 805 primary care (PC) and specialized centers (SC) in all regions. The survey contacted technicians in charge of spirometry and consisted of 36 questions related to the test. The results showed major differences between regions. Most centers had 1-2 spirometers. The number of spirometry tests per week ranged from 2 to 8.9 in PC and between 34.3 and 98.3 in SC. Some training had been given in most centers (63.6-100% in PC and 60.0-100% in SC) but not on a regular basis. Most centers used several short-acting bronchodilators for the bronchodilation test, but with insufficient inhalations (2.0-3.8 in PC and 2.0-3.3 in SC) and frequently incorrect waiting time (29.4-83.3% PC and 33.3-87.5% in SC). Daily calibration was not performed in all centers (0-100% in PC and 66.7-100% in SC). Significant inter-regional differences in spirometry quality criteria were observed, with 6 or more criteria met in 9.1-84.6% of PC centers and 37.5-100% in SC. Our results show the current situation of spirometry in primary and specialized care in Spain, highlighting considerable variability and areas for improvement. This information should be considered by health officials to improve the quality and accessibility of such tests. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  14. Restrictive pattern on spirometry: association with cardiovascular risk and level of physical activity in asymptomatic adults

    Directory of Open Access Journals (Sweden)

    Evandro Fornias Sperandio

    2016-02-01

    Full Text Available Objective : To determine whether a restrictive pattern on spirometry is associated with the level of physical activity in daily life (PADL, as well as with cardiovascular disease (CVD risk factors, in asymptomatic adults. Methods : A total of 374 participants (mean age, 41 ± 14 years underwent spirometry, which included the determination of FVC and FEV1. A restrictive pattern on spirometry was defined as an FEV1/FVC ratio > 0.7 and an FVC < 80% of the predicted value. After conducting demographic, anthropometric, and CVD risk assessments, we evaluated body composition, muscle function, and postural balance, as well as performing cardiopulmonary exercise testing and administering the six-minute walk test. The PADL was quantified with a triaxial accelerometer. Results : A restrictive pattern on spirometry was found in 10% of the subjects. After multivariate logistic regression, adjusted for confounders (PADL and cardiorespiratory fitness, the following variables retained significance (OR; 95% CI as predictors of a restrictive pattern: systemic arterial hypertension (17.5; 1.65-184.8, smoking (11.6; 1.56-87.5, physical inactivity (8.1; 1.43-46.4, larger center-of-pressure area while standing on a force platform (1.34; 1.05-1.71; and dyslipidemia (1.89; 1.12-1.98. Conclusions : A restrictive pattern on spirometry appears to be common in asymptomatic adults. We found that CVD risk factors, especially systemic arterial hypertension, smoking, and physical inactivity, were directly associated with a restrictive pattern, even when the analysis was adjusted for PADL and cardiorespiratory fitness. Longitudinal studies are needed in order to improve understanding of the etiology of a restrictive pattern as well as to aid in the design of preventive strategies.

  15. Quality of routine spirometry tests in Dutch general practices

    Science.gov (United States)

    Schermer, Tjard RJ; Crockett, Alan J; Poels, Patrick JP; van Dijke, Jacob J; Akkermans, Reinier P; Vlek, Hans F; Pieters, Willem R

    2009-01-01

    Background Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care. Aim To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics. Design of study Analysis of routine spirometry test records. Setting Fifteen general practices which had a working agreement with a local hospital pulmonary function laboratory for spirometry assessment regarding test quality and interpretation. Method Spirometry tests were judged by a pulmonary function technician and a chest physician. Proportions of test adequacy were analysed using markers for manoeuvre acceptability and test reproducibility derived from the 1994 American Thoracic Society spirometry guideline. Associations between quality markers and age, sex, and severity of obstruction were examined using logistic regression. Results Practices performed a mean of four (standard deviation = 2) spirometry tests per week; 1271 tests from 1091 adult patients were analysed; 96.4% (95% confidence interval [CI] = 95.6 to 97.2) of all tests consisted of ≥3 blows. With 60.6% of tests, forced expiratory time was the marker with the lowest acceptability rate. An overall 38.8% (95% CI = 36.0 to 41.6) of the tests met the acceptability as well as reproducibility criteria. Age, sex, and severity of obstruction were associated with test quality markers. Conclusion The quality of routine spirometry tests was better than in previous reports from primary care research settings, but there is still substantial room for improvement. Sufficient duration of forced expiratory time is the quality marker with the highest rate of inadequacy. Primary care professionals should be aware of patient characteristics that may diminish the quality of their spirometry tests. Further research is needed to establish to what extent spirometry tests that are inadequate, according to stringent international expert criteria

  16. Use of spirometry in detecting airway obstruction in asymptomatic smokers

    International Nuclear Information System (INIS)

    Bangash, M.H.; Zaidi, S.B.H.; Zaidi, S.M.A.; Khan, I.

    2010-01-01

    Objectives: To detect spirometric abnormalities in asymptomatic smokers in relation to duration of smoking. Study Design: Cross sectional study. Place and Duration of Study: The study was carried out at PNS Shifa from Oct 2006 to June 2007. Subjects and Methods: Hundred individuals were included in this study who fulfilled the required criteria. Spirometry was done after briefing the patient about the procedure. Smokers were divided into two groups. Group I (5 to 9 pack years) and group II (= 10 pack years). All relevant information were recorded on Performa (Annex-A). The data was analyzed through SPSS-10, in terms of Mean +- SD (Standard Deviation) for numeric response variables and independent sample T test was applied to compare significance of proportion for numeric response variables at p < 0.05. Categorical variables were compared by applying Chi-square test at p < 0.05 level of significance. Results: Significant statistical difference was found between the mean age in the two groups with p-value of 0.011. This may be due to the longer duration of smoking history in Group II. Strong association was found between number of cigarette smoked and the pattern of airway obstruction as significant statistical difference of airway obstruction and early airflow limitation was found between the two groups of smokers at p value of 0.004. Conclusion: There is strong association between duration of smoking and development of airway obstruction even before the smoker become symptomatic. (author)

  17. Spirometry in primary care for children with asthma.

    Science.gov (United States)

    Banasiak, Nancy Cantey

    2014-01-01

    Spirometry is an essential part of diagnosing a child with asthma. The National Asthma Education and Prevention Program (NAEPP) and the Global Initiative for Asthma (GINA) expert panels recommend spirometry to be performed on children five years of age and older as an objective assessment of lung function, to diagnosis asthma, and for ongoing yearly management of asthma (GINA, 2012; NAEPP, 2007). According to the NAEPP expert panel, history and physical examination alone are not reliable to accurately diagnose asthma, exclude alternative diagnosis, or determine lung impairment (NAEPP, 2007 Dombkowski, Hassan, Wasilevich, and Clark (2010) found 52% of physicians who provide primary care to children used spirometry, but only 21% used spirometry according to the national guidelines, and only 35% of physicians surveyed were comfortable interpreting the test results. Zanconato, Meneghelli, Braga, Zacchello, and Baraldi (2005) found that 21% of spirometry readings were interpreted incorrectly, concluding that proper training and quality control were important to provide if spirometry in the primary care office setting is to be used. The purpose of this article is to review the appropriate use of spirometry in pediatric primary care.

  18. Spirometry reference values in Indigenous Australians: a systematic review.

    Science.gov (United States)

    Blake, Tamara L; Chang, Anne B; Petsky, Helen L; Rodwell, Leanne T; Brown, Michael G; Hill, Debra C; Thompson, Bruce; McElrea, Margaret S

    2016-07-04

    To evaluate published spirometry data for Australian Aboriginal and Torres Strait Islander (Indigenous) peoples to determine (i) whether their ethnicity influenced spirometry results; and (ii) if any reliable spirometry reference values exist for Indigenous Australians. Systematic review of published and grey literature. PubMed and Cochrane Library databases, references of included articles and appropriate grey literature. Last searches were conducted in April 2016. We included any study that performed spirometry on healthy Indigenous Australians and compared their results with those from people of European ancestry. Two authors independently screened titles and abstracts and then reviewed potentially relevant full-text articles for possible inclusion. We used PRISMA systematic review reporting methods to collate data. Of a possible 125 studies, 18 full-text articles were reviewed, but only nine fulfilled the inclusion criteria. None specified Torres Strait Islander inclusion. All studies reported lower spirometry values (as much as 30% lower) for Aboriginal people compared with non-Indigenous people. Five studies developed spirometry reference values for Indigenous Australians; however, none adhered to all participant inclusion and exclusion criteria outlined by the American Thoracic Society and European Respiratory Society. Hence, reported results and subsequent reference values may not be a true representation of spirometry values in healthy Indigenous people. The lower spirometry values reported for Indigenous Australians may be due to study limitations. Furthermore, there are currently no reliable spirometry reference values for Indigenous Australians that adhere to current guidelines. Developing a set of Indigenous Australian reference values will improve the accuracy of test interpretation and aid in the diagnosis of respiratory disease in this population.

  19. The impact of temporal variability of excess sludge characteristics on the effects obtained in the process of its ultrasonic disintegration.

    Science.gov (United States)

    Tytła, Malwina; Zielewicz, Ewa

    2017-09-13

    This paper aimed to indicate the characteristics of excess sludge, which have the greatest impact on the effects obtained during its ultrasonic disintegration (UD). The direct and technological effects observed after sludge disintegration and anaerobic digestion (AD) depend on the factors affecting the quality of its matrix and simply on the parameters of a disintegrator. Sludge samples originate from a Central Waste Water Treatment Plant in Gliwice, and were collected after mechanical thickening by a monthly period. This approach allowed to observe the temporal changes of sludge characteristics, in a continuous manner. To evaluate the achieved disintegration effects, the following indicators were used: degree of disintegration (DD COD ) and the author's indicators describing the direct and technological effects of UD (ID i , IT i , IT d ), based on the changes in the sludge characteristics. Disintegration was carried out by means of an ultrasonic device equipped with a thin sonotrode. AD was conducted under mesophilic conditions for 20 days. Statistical analysis confirmed that the most important parameters of sludge, which determine obtained effects, were total and volatile solids, capillary suction time, concentration of chemical oxygen demand and pH value. The investigations have also showed that the increase in sludge temperature during its disintegration has a significant impact on the magnitude of other effects obtained in the process.

  20. Face mask spirometry and respiratory pressures in normal subjects.

    NARCIS (Netherlands)

    Wohlgemuth, M.; Kooi, E.L. van der; Hendriks, J.C.M.; Padberg, G.W.A.M.; Folgering, H.T.M.

    2003-01-01

    Spirometry and maximal respiratory pressures are pulmonary function parameters commonly used to evaluate respiratory function. Prediction values are available for conventional lung function devices using a standard tube or flanged type of mouthpiece connection. This equipment is not suitable for

  1. Spirometry in a population of coal miners in Paipa, Colombia

    Directory of Open Access Journals (Sweden)

    Nubia González

    2017-12-01

    Conclusions: Spirometry is a useful test for detecting the presence of respiratory disorders in the population of coal miners. The time of exposure was significantly associated with the respiratory disease exhibited by these miners.

  2. Pharmacists performing quality spirometry testing: an evidence based review.

    Science.gov (United States)

    Cawley, Michael J; Warning, William J

    2015-10-01

    The scope of pharmacist services for patients with pulmonary disease has primarily focused on drug related outcomes; however pharmacists have the ability to broaden the scope of clinical services by performing diagnostic testing including quality spirometry testing. Studies have demonstrated that pharmacists can perform quality spirometry testing based upon international guidelines. The primary aim of this review was to assess the published evidence of pharmacists performing quality spirometry testing based upon American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines. In order to accomplish this, the description of evidence and type of outcome from these services were reviewed. A literature search was conducted using five databases [PubMed (1946-January 2015), International Pharmaceutical Abstracts (1970 to January 2015), Cumulative Index of Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews] with search terms including pharmacy, spirometry, pulmonary function, asthma or COPD was conducted. Searches were limited to publications in English and reported in humans. In addition, Uniform Resource Locators and Google Scholar searches were implemented to include any additional supplemental information. Eight studies (six prospective multi-center trials, two retrospective single center studies) were included. Pharmacists in all studies received specialized training in performing spirometry testing. Of the eight studies meeting inclusion and exclusion criteria, 8 (100%) demonstrated acceptable repeatability of spirometry testing based upon standards set by the ATS/ERS guidelines. Acceptable repeatability of seven studies ranged from 70 to 99% consistent with published data. Available evidence suggests that quality spirometry testing can be performed by pharmacists. More prospective studies are needed to add to the current evidence of quality spirometry testing performed by

  3. Reference values for spirometry in preschool children.

    Science.gov (United States)

    Burity, Edjane F; Pereira, Carlos A C; Rizzo, José A; Brito, Murilo C A; Sarinho, Emanuel S C

    2013-01-01

    Reference values for lung function tests differ in samples from different countries, including values for preschoolers. The main objective of this study was to derive reference values in this population. A prospective study was conducted through a questionnaire applied to 425 preschool children aged 3 to 6 years, from schools and day-care centers in a metropolitan city in Brazil. Children were selected by simple random sampling from the aforementioned schools. Peak expiratory flow (PEF), forced vital capacity (FVC), forced expiratory volumes (FEV1, FEV0.50), forced expiratory flow (FEF25-75) and FEV1/FVC, FEV0.5/FVC and FEF25-75/FVC ratios were evaluated. Of the 425 children enrolled, 321 (75.6%) underwent the tests. Of these, 135 (42.0%) showed acceptable results with full expiratory curves and thus were included in the regression analysis to define the reference values. Height and gender significantly influenced FVC values through linear and logarithmic regression analysis. In males, R(2) increased with the logarithmic model for FVC and FEV1, but the linear model was retained for its simplicity. The lower limits were calculated by measuring the fifth percentile residues. Full expiratory curves are more difficult to obtain in preschoolers. In addition to height, gender also influences the measures of FVC and FEV1. Reference values were defined for spirometry in preschool children in this population, which are applicable to similar populations. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  4. Prevalence of Respiratory Diseases According to Spirometry Findings Among Patients Attending the Spirometry Department of Dhulikhel Hospital.

    Science.gov (United States)

    Prajapati, B K; Pradhan, S

    2016-01-01

    Background Spirometry is a standard test for screening and evaluation of patients with symptoms of cough and shortness of breath. Despite its easy availability, low cost and ease of performance it has not been widely used in clinical practice in Nepal. Objective To assess the prevalence of respiratory diseases in a regional referral centre in patients referred for spirometry. Method This is a descriptive cross-sectional study including patients referred for spirometry to the spirometry unit of Dhulikhel Hospital, Kathmandu University Hospital from 2014 July to 2015 October. The spirometry findings of the patients fulfilling the criteria of American Thoracic Society/European Respitatory Society (ATS/ERS) guidelines were analyzed and categorized as normal, having obstructive lung diseases including chronic obstructive pulmonary disease (COPD) and bronchial asthma or restrictive lung disease. Data were analyzed using SPSS 20.0 software. Result Out of 821 patients, 755 patients (92%) fulfilled ATS/ERS criteria for satisfactory spirometry. The prevalence of COPD was 31.4%, bronchial asthma 24.2% and restrictive lung disease 8.1%. The mean age of patients diagnosed with COPD was 57.8±10.8 years; bronchial asthma 44.3±16.2 years; and restrictive lung disease 44.6±21.5 years. Both COPD and bronchial asthma were common in females. About twenty two percent of the COPD patients were non-smokers and 86.3% of these were females. The most common symptoms for referral was cough and shortness of breath: these symptoms were more likely to be associated with abnormal spirometry findings. Conclusion Spirometry is a crucial preliminary test for evaluation of patients with respiratory symptoms. It should be used more frequently to help stratify patients for appropriate treatment.

  5. Pathway to Best Practice in Spirometry in the Ambulatory Setting.

    Science.gov (United States)

    Peracchio, Carol

    2016-01-01

    Spirometry performed in the ambulatory setting is an invaluable tool for diagnosis, monitoring, and evaluation of respiratory health in patients with chronic lung disease. If spirometry is not performed according to American Thoracic Society (ATS) guidelines, unnecessary repeated testing, increased expenditure of time and money, and increased patient and family anxiety may result. Two respiratory therapists at Mission Health System in Asheville, NC, identified an increase in patients arriving at the pulmonary function testing (PFT) laboratories with abnormal spirometry results obtained in the ambulatory setting. These abnormal results were due to incorrect testing procedure, not chronic lung disease. Three training methods were developed to increase knowledge of correct spirometry testing procedure in the ambulatory setting. The therapists also created a plan to educate offices that do not perform spirometry on the importance and availability of PFT services at our hospital for the population of patients with chronic lung disease. Notable improvements in posttraining test results were demonstrated. The education process was evaluated by a leading respiratory expert, with improvements suggested and implemented. Next steps are listed.

  6. Automated Spirometry Quality Assurance: Supervised Learning From Multiple Experts.

    Science.gov (United States)

    Velickovski, Filip; Ceccaroni, Luigi; Marti, Robert; Burgos, Felip; Gistau, Concepcion; Alsina-Restoy, Xavier; Roca, Josep

    2018-01-01

    Forced spirometry testing is gradually becoming available across different healthcare tiers including primary care. It has been demonstrated in earlier work that commercially available spirometers are not fully able to assure the quality of individual spirometry manoeuvres. Thus, a need to expand the availability of high-quality spirometry assessment beyond specialist pulmonary centres has arisen. In this paper, we propose a method to select and optimise a classifier using supervised learning techniques by learning from previously classified forced spirometry tests from a group of experts. Such a method is able to take into account the shape of the curve as an expert would during visual inspection. We evaluated the final classifier on a dataset put aside for evaluation yielding an area under the receiver operating characteristic curve of 0.88 and specificities of 0.91 and 0.86 for sensitivities of 0.60 and 0.82. Furthermore, other specificities and sensitivities along the receiver operating characteristic curve were close to the level of the experts when compared against each-other, and better than an earlier rules-based method assessed on the same dataset. We foresee key benefits in raising diagnostic quality, saving time, reducing cost, and also improving remote care and monitoring services for patients with chronic respiratory diseases in the future if a clinical decision support system with the encapsulated classifier is to be integrated into the work-flow of forced spirometry testing.

  7. Assessment of Air Pollution Effects on the Respiratory System Based on Pulmonary Function Tests Performed During Spirometry Days.

    Science.gov (United States)

    Dąbrowiecki, Piotr; Mucha, Dominika; Gayer, Anna; Adamkiewicz, Łukasz; Badyda, Artur J

    2015-01-01

    The Polish Spirometry Day is an initiative aimed at increasing awareness of the causes, symptoms, course, and effects that accompany respiratory diseases, especially asthma and chronic obstructive pulmonary disease (COPD). In 2013, the second edition of the Spirometry Day was held. It gathered 180 medical centers and other institution. The final analysis encompassed a total of 1187 persons from 26 different locations, including rural areas, and smaller and larger city agglomerations. Of this total, 755 persons (63.6 %) completed their spirometry tests for the first time in life. Each person fulfilled a questionnaire regarding the personal information, respiratory diseases, symptoms, lifestyle, and a place of residence. In the total group, 234 (19.7 %) cases of bronchial obstruction were diagnosed. A hundred and thirty four persons with obstruction, among those tested for the first time in life (17.8 %), were unaware of their disease. The lowest values of FEV1 and FEF(1)/FVC, corresponding to the highest percentage of persons with obstruction (27.9 %) were observed in small and medium cities (100,000-500,000 inhabitants). There were differences in the prevalence of obstruction depending on the distance of the place of residence from a busy traffic road. A significant decrease of both spirometric variables was observed among people living in cities above 100,000 inhabitants within a distance lower than 50 m from roads. In general, better spirometry results were observed among inhabitants living more than 150 m from main roads.

  8. Effectiveness of spirometry as a motivational tool for smoking cessation: a clinical trial, the ESPIMOAT study.

    Science.gov (United States)

    Irizar-Aramburu, María Isabel; Martínez-Eizaguirre, Jose Manuel; Pacheco-Bravo, Petra; Diaz-Atienza, Maria; Aguirre-Arratibel, Iñigo; Peña-Peña, Maria Isabel; Alba-Latorre, Mercedes; Galparsoro-Goikoetxea, Mikel

    2013-12-05

    Smoking is the main preventable cause of morbidity and mortality in our region, it being the main causative agent of chronic obstructive pulmonary disease. There still is no consensus on the use of spirometry as a strategy for smoking cessation, given that there is insufficient scientific evidence from high quality studies to recommend the use of this technique. This is to be a randomized, multicentre, open-label clinical trial. A total of 444 smokers over 40 years of age will be recruited by 39 general practitioners from 22 health centers. Primary objective of this study is to assess the effectiveness of spirometry together with information regarding the test for smoking cessation after 1 year in smokers over 40 years of age with a more than 10 pack-year history and no previous diagnosis of chronic obstructive pulmonary disease. Groups of 45 patients who smoke will be randomly selected from the lists of the participating doctors. The names will be sent to the corresponding doctors who will contact candidate patients and assess whether they meet the selection criteria. Patients who meet these criteria will be randomly allocated to an intervention or control group. For patients in both groups, a nurse will conduct an interview and perform a spirometry test to measure forced vital capacity. Then, all patients will be referred for an appointment with their doctor for brief anti-smoking intervention, patients from the intervention group additionally being informed about the result of the spirometry test. After 1 year, smoking status will be assessed and, in those who report that they have quit smoking, abstinence will be confirmed by co-oximetry. Data will be analyzed on an intention-to-treat basis using the chi-squared test for outcomes and binary logistic regression if it is considered to be necessary to adjust for confounding variables. Performing a spirometry test and providing information on pulmonary function may increase awareness of the effect of smoking among

  9. Interpretation of Spirometry: Selection of Predicted Values and Defining Abnormality.

    Science.gov (United States)

    Chhabra, S K

    2015-01-01

    Spirometry is the most frequently performed investigation to evaluate pulmonary function. It provides clinically useful information on the mechanical properties of the lung and the thoracic cage and aids in taking management-related decisions in a wide spectrum of diseases and disorders. Few measurements in medicine are so dependent on factors related to equipment, operator and the patient. Good spirometry requires quality assured measurements and a systematic approach to interpretation. Standard guidelines on the technical aspects of equipment and their calibration as well as the test procedure have been developed and revised from time-to-time. Strict compliance with standardisation guidelines ensures quality control. Interpretation of spirometry data is based only on two basic measurements--the forced vital capacity (FVC) and the forced expiratory volume in 1 second (FEV1) and their ratio, FEV1/FVC. A meaningful and clinically useful interpretation of the measured data requires a systematic approach and consideration of several important issues. Central to interpretation is the understanding of the development and application of prediction equations. Selection of prediction equations that are appropriate for the ethnic origin of the patient is vital to avoid erroneous interpretation. Defining abnormal values is a debatable but critical aspect of spirometry. A statistically valid definition of the lower limits of normal has been advocated as the better method over the more commonly used approach of defining abnormality as a fixed percentage of the predicted value. Spirometry rarely provides a specific diagnosis. Examination of the flow-volume curve and the measured data provides information to define patterns of ventilatory impairment. Spirometry must be interpreted in conjunction with clinical information including results of other investigations.

  10. Oscillometry complements spirometry in evaluation of subjects following toxic inhalation

    Directory of Open Access Journals (Sweden)

    Kenneth I. Berger

    2015-12-01

    Full Text Available The World Trade Center (WTC destruction released dust and fumes into the environment. Although many community members developed respiratory symptoms, screening spirometry was usually normal. We hypothesised that forced oscillation testing would identify functional abnormalities undetected by spirometry and that symptom severity would relate to magnitude of abnormalities measured by oscillometry. A symptomatic cohort (n=848 from the Bellevue Hospital WTC Environmental Health Center was evaluated and compared to an asymptomatic cohort (n=475 from the New York City Department of Health WTC Health Registry. Spirometry and oscillometry were performed. Oscillometry measurements included resistance (R5 and frequency dependence of resistance (R5−20. Spirometry was normal for the majority of subjects (73.2% symptomatic versus 87.6% asymptomatic, p<0.0001. In subjects with normal spirometry, R5 and R5−20 were higher in symptomatic versus asymptomatic subjects (median (interquartile range R5 0.436 (0.206 versus 0.314 (0.129 kPa·L−1·s−1, p<0.001; R5−20 0.075 (0.085 versus 0.004 (0.042 kPa·L−1·s−1, p<0.0001. In symptomatic subjects, R5 and R5−20 increased with increasing severity and frequency of wheeze (p<0.05. Measurement of R5–20 correlated with the presence and severity of symptoms even when spirometry was within normal limits. These findings are in accord with small airway abnormalities as a potential explanation of the respiratory symptoms.

  11. Oscillometry complements spirometry in evaluation of subjects following toxic inhalation

    Science.gov (United States)

    Berger, Kenneth I.; Turetz, Meredith; Liu, Mengling; Shao, Yongzhao; Kazeros, Angeliki; Parsia, Sam; Caplan-Shaw, Caralee; Friedman, Stephen M.; Maslow, Carey B.; Marmor, Michael; Goldring, Roberta M.

    2015-01-01

    The World Trade Center (WTC) destruction released dust and fumes into the environment. Although many community members developed respiratory symptoms, screening spirometry was usually normal. We hypothesised that forced oscillation testing would identify functional abnormalities undetected by spirometry and that symptom severity would relate to magnitude of abnormalities measured by oscillometry. A symptomatic cohort (n=848) from the Bellevue Hospital WTC Environmental Health Center was evaluated and compared to an asymptomatic cohort (n=475) from the New York City Department of Health WTC Health Registry. Spirometry and oscillometry were performed. Oscillometry measurements included resistance (R5) and frequency dependence of resistance (R5−20). Spirometry was normal for the majority of subjects (73.2% symptomatic versus 87.6% asymptomatic, p<0.0001). In subjects with normal spirometry, R5 and R5−20 were higher in symptomatic versus asymptomatic subjects (median (interquartile range) R5 0.436 (0.206) versus 0.314 (0.129) kPa·L−1·s−1, p<0.001; R5−20 0.075 (0.085) versus 0.004 (0.042) kPa·L−1·s−1, p<0.0001). In symptomatic subjects, R5 and R5−20 increased with increasing severity and frequency of wheeze (p<0.05). Measurement of R5–20 correlated with the presence and severity of symptoms even when spirometry was within normal limits. These findings are in accord with small airway abnormalities as a potential explanation of the respiratory symptoms. PMID:27730155

  12. Phenotype of normal spirometry in an aging population.

    Science.gov (United States)

    Vaz Fragoso, Carlos A; McAvay, Gail; Van Ness, Peter H; Casaburi, Richard; Jensen, Robert L; MacIntyre, Neil; Gill, Thomas M; Yaggi, H Klar; Concato, John

    2015-10-01

    In aging populations, the commonly used Global Initiative for Chronic Obstructive Lung Disease (GOLD) may misclassify normal spirometry as respiratory impairment (airflow obstruction and restrictive pattern), including the presumption of respiratory disease (chronic obstructive pulmonary disease [COPD]). To evaluate the phenotype of normal spirometry as defined by a new approach from the Global Lung Initiative (GLI), overall and across GOLD spirometric categories. Using data from COPDGene (n = 10,131; ages 45-81; smoking history, ≥10 pack-years), we evaluated spirometry and multiple phenotypes, including dyspnea severity (Modified Medical Research Council grade 0-4), health-related quality of life (St. George's Respiratory Questionnaire total score), 6-minute-walk distance, bronchodilator reversibility (FEV1 % change), computed tomography-measured percentage of lung with emphysema (% emphysema) and gas trapping (% gas trapping), and small airway dimensions (square root of the wall area for a standardized airway with an internal perimeter of 10 mm). Among 5,100 participants with GLI-defined normal spirometry, GOLD identified respiratory impairment in 1,146 (22.5%), including a restrictive pattern in 464 (9.1%), mild COPD in 380 (7.5%), moderate COPD in 302 (5.9%), and severe COPD in none. Overall, the phenotype of GLI-defined normal spirometry included normal adjusted mean values for dyspnea grade (0.8), St. George's Respiratory Questionnaire (15.9), 6-minute-walk distance (1,424 ft [434 m]), bronchodilator reversibility (2.7%), % emphysema (0.9%), % gas trapping (10.7%), and square root of the wall area for a standardized airway with an internal perimeter of 10 mm (3.65 mm); corresponding 95% confidence intervals were similarly normal. These phenotypes remained normal for GLI-defined normal spirometry across GOLD spirometric categories. GLI-defined normal spirometry, even when classified as respiratory impairment by GOLD, included adjusted mean values in the

  13. Spatial variability of excess mortality during prolonged dust events in a high-density city: a time-stratified spatial regression approach.

    Science.gov (United States)

    Wong, Man Sing; Ho, Hung Chak; Yang, Lin; Shi, Wenzhong; Yang, Jinxin; Chan, Ta-Chien

    2017-07-24

    Dust events have long been recognized to be associated with a higher mortality risk. However, no study has investigated how prolonged dust events affect the spatial variability of mortality across districts in a downwind city. In this study, we applied a spatial regression approach to estimate the district-level mortality during two extreme dust events in Hong Kong. We compared spatial and non-spatial models to evaluate the ability of each regression to estimate mortality. We also compared prolonged dust events with non-dust events to determine the influences of community factors on mortality across the city. The density of a built environment (estimated by the sky view factor) had positive association with excess mortality in each district, while socioeconomic deprivation contributed by lower income and lower education induced higher mortality impact in each territory planning unit during a prolonged dust event. Based on the model comparison, spatial error modelling with the 1st order of queen contiguity consistently outperformed other models. The high-risk areas with higher increase in mortality were located in an urban high-density environment with higher socioeconomic deprivation. Our model design shows the ability to predict spatial variability of mortality risk during an extreme weather event that is not able to be estimated based on traditional time-series analysis or ecological studies. Our spatial protocol can be used for public health surveillance, sustainable planning and disaster preparation when relevant data are available.

  14. Variation in spirometry utilization between trained general practitioners in practices equipped with a spirometer.

    NARCIS (Netherlands)

    Poels, P.J.E.; Schermer, T.R.J.; Jacobs, A.; Akkermans, R.P.; Hartman, J.; Bottema, B.J.A.M.; Weel, C. van

    2006-01-01

    OBJECTIVE: To explore spirometry utilization among general practitioners and identify practitioner and practice-related factors associated with spirometry utilization. DESIGN: Multivariate multilevel cross-sectional analysis of a questionnaire survey. SETTING: Some 61 general practices involved in a

  15. Influence of the diving wetsuit on standard spirometry

    NARCIS (Netherlands)

    Schellart, Nico A. M.; Sterk, Wouter

    2016-01-01

    INTRODUCTION A well-fitting wetsuit exerts a pressure on the body that may influence spirometry. This pressure is expected to reduce the forced vital capacity (FVC) due to hampered inspiration. Since the shape of the spirometric flow curve should not be changed by the pressure effects of the

  16. Spirometry: a predictor of lung cancer among asbestos workers.

    Science.gov (United States)

    Świątkowska, Beata; Szeszenia-Dąbrowska, Neonila

    2017-01-01

    The significance of lung function as an independent risk factor for lung cancer remains unclear. The objective of the study is to answer the question if spirometry can identify patients at risk for lung cancer among people occupationally exposed to asbestos dust in the past. In order to identify a group of individuals with the highest risk of lung cancer incidence based on lung function levels of FEV 1 % predicted value, we examined 6882 subjects enrolled in the health surveillance program for asbestos related diseases over the years 2000-2014. We found a total of 110 cases confirmed as primary lung cancer. Using Cox's proportional hazards model after adjustment for age, gender, number of cigarettes, duration of smoking and cumulative asbestos exposure, we estimated that compared with the subjects with FEV 1 ≥90% pred, the HR of lung cancer was 1.40 (95%CI: 0.94-2.08) for the subjects with FEV 1 less than 90% and 1.95 (HR = 1.86; 95%CI: 1.12-3.08) for those with FEV 1 less than 70%. In addition, probability of the occurrence of lung cancer for FEV 1 spirometry and cancer diagnosis was three years or less. The results strongly support the hypothesis that spirometry can identify patients at a risk of lung cancer development. Regular spirometry should be offered to all patients with a history of asbestos exposure, at least once every three years.

  17. A Rwandan spirometry and resting ventilation study | Gahutu ...

    African Journals Online (AJOL)

    To illustrate spirometric population variation and ventilatory adaptation to moderate altitude, we report the spirometric and resting ventilation values observed in a student population in Butare, Rwanda (altitude: 1 768 m; barometric pressure: 629 mm Hg). Spirometry was carried out with a Mijnhardt Volutest VT-3 ...

  18. A guide to spirometry as applied to occupational health | White ...

    African Journals Online (AJOL)

    In the context of occupational health, spirometric testing of respiratory function has a number of important applications. These applications can be expected to become more widespread in view of extensive changes to occupational health and compensation legislation in South Africa. Spirometry is an essential component of ...

  19. Accuracy and Quality of Spirometry in Primary Care Offices.

    Science.gov (United States)

    Hegewald, Matthew J; Gallo, Heather M; Wilson, Emily L

    2016-12-01

    Spirometry is necessary for the optimal management of patients with respiratory disease. The quality of spirometry performed in the primary care setting has been inconsistent. We aimed to evaluate spirometer accuracy, determine the clinical significance of inaccurate spirometers, and assess the quality of spirograms obtained in primary care offices. We tested 17 spirometers used in primary care offices with a waveform generator; accuracy and precision were assessed using American Thoracic Society criteria. The clinical significance of inaccurate instruments was determined by applying the FEV 1 /FVC error from an obstructed waveform to a clinical data set. Spirogram quality was determined by grading spirograms using acceptability and repeatability criteria. The relationship between the number of tests performed by a clinic and test quality was assessed. Only 1 of 17 spirometers met accuracy criteria, with mean errors for FVC, FEV 1 , and FEV 1 /FVC ranging from 1.7 to 3.1%. Applying the percentage error to a clinical data set resulted in 28% of tests being recategorized from obstructed to nonobstructed. Of the spirograms reviewed, 60% were considered acceptable for clinical use. There was no association between the number of tests performed by a clinic and spirometry quality. Most spirometers tested were not accurate. The magnitude of the errors resulted in significant changes in the categorization of patients with obstruction. Acceptable-quality tests were produced for only 60% of patients. Our results raise concerns regarding the utility of spirometry obtained in primary care offices without greater attention to quality assurance and training.

  20. Spirometry of healthy adult South African men | Louw | South African ...

    African Journals Online (AJOL)

    An exhaustive questionnaire and radiographic screening process was used to identify a healthy population. Spirometry was performed using two calibrated instruments, a sleeve sealed piston spirometer (Autolink) and a bellows spirometer (Vitalograph). The methodological guidelines of the American Thoracic Society were ...

  1. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  2. Spirometry filters can be used to detect exhaled respiratory viruses.

    Science.gov (United States)

    Mitchell, Alicia B; Mourad, Bassel; Tovey, Euan; Buddle, Lachlan; Peters, Matthew; Morgan, Lucy; Oliver, Brian G

    2016-09-26

    Respiratory viruses are very common in the community and contribute to the burden of illness for patients with chronic respiratory diseases, including acute exacerbations. Traditional sampling methods are invasive and problematic to repeat. Accordingly, we explored whether respiratory viruses could be isolated from disposable spirometry filters and whether detection of viruses in this context represented presence in the upper or lower respiratory tract. Discovery (n  =  53) and validation (n  =  49) cohorts were recruited from a hospital outpatient department during two different time periods. Spirometry mouthpiece filters were collected from all participants. Respiratory secretions were sampled from the upper and lower respiratory tract by nasal washing (NW), sputum, and bronchoalveolar lavage (BAL). All samples were examined using RT-PCR to identify a panel of respiratory viruses (rhinovirus, respiratory syncytial virus, influenza A, influenza B, parainfluenza virus 1, 2 & 3, and human metapneumovirus). Rhinovirus was quantified using qPCR. Paired filter-NW samples (n  =  29), filter-sputum samples (n  =  24), filter-BAL samples (n  =  39) and filter-NW-BAL samples (n  =  10) provided a range of comparisons. At least one virus was detected in any sample in 85% of participants in the discovery cohort versus 45% in the validation cohort. Overall, 72% of viruses identified in the paired comparator method matched those detected in spirometry filters. There was a high correlation between viruses identified in spirometry filters compared with viruses identified in both the upper and lower respiratory tract using traditional sampling methods. Our results suggest that examination of spirometry filters may be a novel and inexpensive sampling method for the presence of respiratory viruses in exhaled breath.

  3. Excessive growth.

    Science.gov (United States)

    Narayanaswamy, Vasudha; Rettig, Kenneth R; Bhowmick, Samar K

    2008-09-01

    Tall stature and excessive growth syndrome are a relatively rare concern in pediatric practice. Nevertheless, it is important to identify abnormal accelerated growth patterns in children, which may be the clue in the diagnosis of an underlying disorder. We present a case of pituitary gigantism in a 2 1/2-year-old child and discuss the signs, symptoms, laboratory findings, and the treatment. Brief discussions on the differential diagnosis of excessive growth/tall stature have been outlined. Pituitary gigantism is very rare in the pediatrics age group; however, it is extremely rare in a child that is less than 3 years of age. The nature of pituitary adenoma and treatment options in children with this condition have also been discussed.

  4. Overall and peripheral lung function assessment by spirometry and forced oscillation technique in relation to asthma diagnosis and control.

    Science.gov (United States)

    Heijkenskjöld Rentzhog, C; Janson, C; Berglund, L; Borres, M P; Nordvall, L; Alving, K; Malinovschi, A

    2017-12-01

    Classic spirometry is effort dependent and of limited value in assessing small airways. Peripheral airway involvement, and relation to poor control, in asthma, has been highlighted recently. Forced oscillation technique (FOT) offers an effort-independent assessment of overall and peripheral lung mechanics. We studied the association between lung function variables, obtained either by spirometry or multifrequency (5, 11 and 19 Hz) FOT, and asthma diagnosis and control. Spirometry measures, resistance at 5 (R5) and 19 Hz (R19), reactance at 5 Hz (X5), resonant frequency (f res ), resistance difference between 5-19 Hz (R5-R19) and Asthma Control Test scores were determined in 234 asthmatic and 60 healthy subjects (aged 13-39 years). We used standardized lung function variables in logistic regression analyses, unadjusted and adjusted for age, height, gender and weight. Lower FEV 1 /FVC (OR [95% CI] 0.47 [0.32, 0.69]) and FEF 50 (0.62 [0.46, 0.85]) per standard deviation increase, and higher R5 (3.31 [1.95, 5.62]) and R19 (2.54 [1.65, 3.91]) were associated with asthma diagnosis. Independent predictive effects of FEV 1 /FVC and R5 or R19, respectively, were found for asthma diagnosis. Lower FEV 1 /FVC and altered peripheral FOT measures (X5, f res and R5-R19) were associated with uncontrolled asthma (P-values < .05). Resistance FOT measures were equally informative as spirometry, related to asthma diagnosis, and, furthermore, offered additive information to FEV 1 /FVC, supporting a complementary role for FOT. Asthma control was related to FOT measures of peripheral airways, suggesting a potential use in identifying such involvement. Further studies are needed to determine a clinical value and relevant reference values in children, for the multifrequency FOT measurements. © 2017 John Wiley & Sons Ltd.

  5. Criteria for inhalation exposure systems utilizing concurrent flow spirometry

    International Nuclear Information System (INIS)

    Raabe, O.G.; Yeh, H.C.

    1974-01-01

    Principles are given for the design and operation of a new class of inhalation exposure systems utilizing concurrent flow spirometry (CFS), a simple method for providing realtime measurement of respiratory volumes and rates during inhalation exposure by mouth or nose of individual experimental animals or man to aerosols or gases. This technique is especially useful for inhalation exposure of larger experimental animals, such as horses, where whole-body plethysmography is usually impractical. Difficulties encountered with conventional exposure systems in maintenance of uniform aerosol or gas concentrations and prevention of large pressure excursions in the exposure chamber during breathing are obviated by systems utilizing the principles of concurrent flow spirometry. For illustration, two exposure units with CFS are described, one for exposure of Beagle dogs and one for ponies. (U.S.)

  6. The Use of Home Spirometry in Pediatric Cystic Fibrosis Patients

    Directory of Open Access Journals (Sweden)

    Aarti Shakkottai MD

    2017-02-01

    Full Text Available Medication adherence is poor among pediatric cystic fibrosis (CF patients, with adolescents having one of the lowest adherence rates. We wanted to identify an adherence intervention that would be acceptable to CF adolescents and assess its feasibility. We surveyed 40 adolescents with CF and asked about barriers to and motivators for their own adherence and to generate ideas for potential adherence interventions. Since most of the respondents chose frequent spirometry at home and medication reminders for interventions, we selected 5 subjects, 10 to 14 years of age, with CF to test the feasibility of home spirometry and medication reminders in pediatric CF patients. This article summarizes the results of both the survey and the feasibility pilot study.

  7. Spirometry improvement after muscular exercise in elite swimmers.

    Science.gov (United States)

    Rubini, Alessandro; Rizzato, Alex; Fava, Simone; Olivato, Nicola; Mangar, Devanand; Camporesi, Enrico M; Bosco, Gerardo

    2017-12-01

    An increased sympathetic activity during muscular effort is a well established physiological response, whose intensity is known to increase with the muscular load. Spirometry was described to improve as an effect of swimming training in healthy and asthmatic subjects, suggesting a decrease in airway resistance The aim was to investigate the possible effect of muscular exercise (swimming) on spirometry, in particular searching for possible differences because of different swimming times. The measurements were performed on 9 highly trained male competitive swimmers (age: 41±12.79 years, height: 1.69±0.06 meters, weight: 66.14±14.28 kg, BMI: 22.8±3.61 kg/m2) during an official competition. The data were collected at the border of the swimming-pool before (control, C) and few minutes after the swimming sessions (exercise, E), which consisted either of 800 meter (7 subjects) or 1500 meter (5 subjects) free style. A general trend indicating a postexercise increase in spirometry was observed. We found post-exercise significant increments in FEV1 and in MEF75 for both the 800 and 1500 meter swimming sessions, and in FEF25-75 and in MEF25 for the shorter distance. We conclude that, as it may be expected, muscular exercise induces an improvement of spirometry both because of a smooth muscle relaxation-induced modulation of airway diameter and resistance to airflow, and because of an enhanced expiratory muscle contraction strength. Both of these mechanisms are related to an increased sympathetic activity which is well known to accompany muscular exercise.

  8. Pulmonary involvement in rheumatoid arthritis: evaluation by radiography and spirometry *

    Science.gov (United States)

    Kawassaki, Alexandre Melo; Pereira, Daniel Antunes Silva; Uliana Kay, Fernando; Laurindo, Ieda Maria Magalhães; Carvalho, Carlos Roberto Ribeiro; Kairalla, Ronaldo Adib

    2015-01-01

    Abstract Objective: To determine whether simple diagnostic methods can yield relevant disease information in patients with rheumatoid arthritis (RA). Methods: Patients with RA were randomly selected for inclusion in a cross-sectional study involving clinical evaluation of pulmonary function, including pulse oximetry (determination of SpO2, at rest), chest X-ray, and spirometry. Results: A total of 246 RA patients underwent complete assessments. Half of the patients in our sample reported a history of smoking. Spirometry was abnormal in 30% of the patients; the chest X-ray was abnormal in 45%; and the SpO2 was abnormal in 13%. Normal chest X-ray, spirometry, and SpO2 were observed simultaneously in only 41% of the RA patients. A history of smoking was associated with abnormal spirometry findings, including evidence of obstructive or restrictive lung disease, and with abnormal chest X-ray findings, as well as with an interstitial pattern on the chest X-ray. Comparing the patients in whom all test results were normal (n = 101) with those in whom abnormal test results were obtained (n = 145), we found a statistically significant difference between the two groups, in terms of age and smoking status. Notably, there were signs of airway disease in nearly half of the patients with minimal or no history of tobacco smoke exposure. Conclusions: Pulmonary involvement in RA can be identified through the use of a combination of diagnostic methods that are simple, safe, and inexpensive. Our results lead us to suggest that RA patients with signs of lung involvement should be screened for lung abnormalities, even if presenting with no respiratory symptoms. PMID:26398753

  9. PIKO-6® vs. forced spirometry in asthmatic children.

    Science.gov (United States)

    Gochicoa-Rangel, Laura; Larios-Castañeda, Pablo José; Miguel-Reyes, José Luis; Briseño, David Martínez; Flores-Campos, Roberto; Sáenz-López, Juan Arturo; Torre-Bouscoulet, Luis

    2014-12-01

    The PIKO-6® is an electronic device that measures forced expiratory volume at seconds 1 (FEV1) and 6 (FEV6) of a forced vital capacity (FVC) maneuver. This device could aid in diagnosing obstructive respiratory diseases. To determine the concordance of FEV1, FEV6, and the FEV1/FEV6 quotient achieved with PIKO-6® versus spirometric values from asthmatic patients, and compare results with measures from healthy children. A cross-sectional study with asthmatic and healthy 6-to-14-year-old children, all of whom performed a forced spirometry as well as a PIKO-6® test. The study included 82 subjects (58 asthmatics, 24 healthy children). Except for the functional parameters, the basal characteristics of the two groups were similar. The concordance correlation coefficient (CCC) for FEV1 was 0.938 (P spirometry was lower in patients with partially controlled or uncontrolled asthma compared to controlled or healthy children. The broad limits of agreement show that the FEV1, FEV6, and FEV1/FEV6 obtained with the PIKO-6® are not interchangeable with spirometry results. Longitudinal evaluations of asthma patients are necessary to assess the utility of PIKO-6®. © 2014 Wiley Periodicals, Inc.

  10. Spirometry. Spanish Society of Pulmonology and Thoracic Surgery (SEPAR).

    Science.gov (United States)

    García-Río, Francisco; Calle, Myriam; Burgos, Felip; Casan, Pere; Del Campo, Félix; Galdiz, Juan B; Giner, Jordi; González-Mangado, Nicolás; Ortega, Francisco; Puente Maestu, Luis

    2013-09-01

    Spirometry is the main pulmonary function test and is essential for the evaluation and monitoring of respiratory diseases. Its utility transcends the field of Respiratory Medicine, is becoming increasingly important in primary care and applications have even been described outside the field of respiratory diseases. This document is therefore intended to serve as support for all health professionals who use spirometry, providing recommendations based on the best scientific evidence available. An update of the indications and contraindications of the test is proposed. The document sets out recommendations on the requirements necessary for conventional spirometers and portable office equipment, as well as on spirometer hygiene and quality control measures. Spirometric parameters that must be considered, performance of manoeuvres, criteria for acceptability and repeatability of measurements and their quality control are defined. A proposal is also established for presentation of the results and an evaluation and interpretation is proposed according to information generated in recent years. Finally, lines of adaptation and integration of spirometry in the field of new technologies are considered. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  11. The Role of Incentive Spirometry in Primary Spontaneous Pneumothorax.

    Science.gov (United States)

    Pribadi, Rabbinu R; Singh, Gurmeet; Rumende, Cleopas M

    2016-01-01

    Pneumothorax is the presence of air in the pleural space. Its management consists of noninvasive and invasive therapies and it is determined based on clinical manifestations, type and size of pneumothorax. We present a case of a patient with diagnosis of primary spontaneous pneumothorax treated with incentive spirometry (noninvasive therapy). A 20 year old man came to respirology clinic with chief complaint of shortness of breath. He was recently diagnosed with left pneumothorax based on previous chest X-ray in another health care facilities and was advised to undergo tube thoracostomy but he refused the procedure. On physical examination, vital signs were normal. Chest X-ray showed 33% of pneumothorax or 1.2 cm. He was asked to perform incentive spirometry therapy at home. During 12 days of therapy, shortness of breath slowly disappeared and on repeated chest X-ray, it showed minimal pneumothorax in the left upper hemithorax. Noninvasive treatment such as incentive spirometry can be considered in patient with minimal symptoms and no signs of life-threatening respiratory distress.

  12. Spirometry use: detection of chronic obstructive pulmonary disease in the primary care setting

    Science.gov (United States)

    Barnes, Thomas A; Fromer, Len

    2011-01-01

    Objective: To describe a practical method for family practitioners to stage chronic obstructive pulmonary disease (COPD) by the use of office spirometry. Methods: This is a review of the lessons learned from evaluations of the use of office spirometry in the primary care setting to identify best practices using the most recent published evaluations of office spirometry and the analysis of preliminary data from a recent spirometry mass screening project. A mass screening study by the American Association for Respiratory Care and the COPD Foundation was used to identify the most effective way for general practitioners to implement office spirometry in order to stage COPD. Results: A simple three-step method is described to identify people with a high pre-test probability in an attempt to detect moderate to severe COPD: COPD questionnaire, measurement of peak expiratory flow, and office spirometry. Clinical practice guidelines exist for office spirometry basics for safety, use of electronic peak flow devices, and portable spirometers. Conclusion: Spirometry can be undertaken in primary care offices with acceptable levels of technical expertise. Using office spirometry, primary care physicians can diagnose the presence and severity of COPD. Spirometry can guide therapies for COPD and predict outcomes when used in general practice. PMID:21472091

  13. Spirometry reference equations for central European populations from school age to old age.

    Science.gov (United States)

    Rochat, Mascha K; Laubender, Ruediger P; Kuster, Daniela; Braendli, Otto; Moeller, Alexander; Mansmann, Ulrich; von Mutius, Erika; Wildhaber, Johannes

    2013-01-01

    Spirometry reference values are important for the interpretation of spirometry results. Reference values should be updated regularly, derived from a population as similar to the population for which they are to be used and span across all ages. Such spirometry reference equations are currently lacking for central European populations. To develop spirometry reference equations for central European populations between 8 and 90 years of age. We used data collected between January 1993 and December 2010 from a central European population. The data was modelled using "Generalized Additive Models for Location, Scale and Shape" (GAMLSS). The spirometry reference equations were derived from 118'891 individuals consisting of 60'624 (51%) females and 58'267 (49%) males. Altogether, there were 18'211 (15.3%) children under the age of 18 years. We developed spirometry reference equations for a central European population between 8 and 90 years of age that can be implemented in a wide range of clinical settings.

  14. Risk for COPD with Obstruction of Active Smokers with Normal Spirometry and Reduced Diffusion Capacity

    Science.gov (United States)

    Kaner, Robert J.; Sanders, Abraham; Vincent, Thomas L.; Mezey, Jason G.; Crystal, Ronald G.

    2016-01-01

    Background Smokers are assessed for COPD using spirometry, with COPD defined by the Global Initiative for Chronic Obstructive Lung Disease (GOLD) as airflow limitation not fully reversible with bronchodilators. There is a subset of smokers with normal spirometry (by GOLD criteria), who have a low diffusion capacity (DLCO), a parameter linked to emphysema and small airway disease. The natural history of these “normal spirometry/low DLCO” smokers is unknown. Methods From a cohort of 1570 smokers in the New York City metropolitian area, all of whom had normal spirometry, two groups were randomly selected for lung function follow-up: smokers with normal spirometry/normal DLCO (n=59) and smokers with normal spirometry/low DLCO (n=46). All had normal history, physical examination, CBC, urinalysis, HIV status, α1-antitrypsin level, chest X-ray, FEV1, FVC, FEV1/FVC ratio and total lung capacity (TLC). Throughout the study, all continued to be active smokers. Findings In the normal spirometry/normal DLCO group assessed over 45 ± 20 months, 3% developed GOLD-defined COPD. In contrast, in the normal spirometry/low DLCO group, followed over 41 ± 31 months, 22% developed GOLD-defined COPD. Interpretation Despite appearing “normal” by GOLD, smokers with normal spirometry but low DLCO are at significant risk for developing COPD with obstruction to airflow. PMID:26541521

  15. The objective evaluation of obstructive pulmonary diseases with spirometry

    Directory of Open Access Journals (Sweden)

    Özkaya S

    2016-08-01

    Full Text Available Sevket Ozkaya,1 Adem Dirican,2 Tibel Tuna3 1Department of Pulmonary Medicine, Faculty of Medicine, Bahçes¸ehir University, Istanbul, 2Department of Pulmonary Medicine, Samsun Medical Park Hospital, 3Department of Pulmonary Medicine, Samsun Chest Diseases and Thoracic Surgery Hospital, Samsun, Turkey Abstract: Airway obstruction is variable in asthma, while it is progressive and persistent in chronic bronchitis and emphysema. However, some of the patients presenting with symptoms of chronic airway diseases have clinical features of both asthma and COPD. The group with “Asthma–COPD Overlap Syndrome” (ACOS phenotype was characterized by definitely irreversible airway obstruction accompanied by symptoms and signs of reversibility. In this study, we aimed to classify obstructive airway diseases by clinical, radiological, and pulmonary function tests. Patients at Samsun Medical Park Hospital Chest Diseases outpatient clinic were evaluated between January 2013 and April 2016, and a total of 235 patients were included in this study. Mean age of the patients was 55.3±14.5 (15–88 years, and the male/female ratio was 45/190. The baseline pulmonary function test results of the patients were as follows: mean forced vital capacity (FVC values 2,825±1,108 (710–6,870 mL and 74.3±22.4 (24–155%, forced expiratory volume in 1 second (FEV1 values 1,789±774 (480–4,810 mL and 58.1±20.0 (20–130%, FEV1/FVC values 62.5±6.8 (39–70%. Reversibility criteria following bronchodilator treatment were present in 107 (45.5% patients. We specified five subgroups for patients according to their clinical, radiological, and pulmonary test findings, namely Group 1 (asthma, Group 2 (ACOS, Group 3 (chronic bronchitis, and Group 4 (emphysema. Additionally, a group of patients who had clinical and spirometric features of both asthma and chronic bronchitis in association with underlying emphysema (emphysema with chronic bronchitis and emphysema with asthma

  16. Spirometry Use among Older Adults with Chronic Obstructive Pulmonary Disease: 1999–2008

    Science.gov (United States)

    Wang, Yue; Kuo, Yong-Fang; Goodwin, James S.; Sharma, Gulshan

    2013-01-01

    Rationale: Clinical practice guidelines recommend spirometry to diagnose chronic obstructive pulmonary disease (COPD) and facilitate management. National trends in spirometry use in older adults with newly diagnosed COPD are not known. Objectives: To examine the rate and beneficiary characteristics associated with spirometry use in subjects with newly diagnosed COPD between 1999 and 2008. Methods: We examined newly diagnosed beneficiaries with COPD using a 5% Medicare population from 1999 to 2008. A new COPD diagnosis required two outpatient visits or one hospitalization with primary International Classification of Diseases, 9th edition code 491.xx, 492.xx, or 496 occurring at least 30 days apart with none in the prior 12 months. The primary measurement was spirometry performed within 365 days (±) of the first claim with a COPD diagnosis. Measurements and Main Results: Between 1999 and 2008, 64,985 subjects were newly diagnosed with COPD. Of these, 35,739 (55%) had spirometry performed within 1 year before or after the initial diagnosis of COPD. Spirometry use increased from 51.3% in 1999 to 58.3% in 2008 (P spirometry. In a multivariable analysis, compared with 1999, subjects diagnosed in 2008 had 10% higher odds (odds ratio, 1.10; 95% confidence interval, 1.06–1.13) of having spirometry performed. Conclusions: Despite an increase in the use of spirometry over time in newly diagnosed older adults with COPD, spirometry use remains low. Clinical practice guidelines and educational efforts should focus on increasing the use of spirometry to diagnose and manage COPD. PMID:24053440

  17. Confirmatory spirometry for adults hospitalized with a diagnosis of asthma or chronic obstructive pulmonary disease exacerbation

    Science.gov (United States)

    2012-01-01

    Background Objective measurement of airflow obstruction by spirometry is an essential part of the diagnosis of asthma or COPD. During exacerbations, the feasibility and utility of spirometry to confirm the diagnosis of asthma or chronic obstructive pulmonary disease (COPD) are unclear. Addressing these gaps in knowledge may help define the need for confirmatory testing in clinical care and quality improvement efforts. This study was designed to determine the feasibility of spirometry and to determine its utility to confirm the diagnosis in patients hospitalized with a physician diagnosis of asthma or COPD exacerbation. Methods Multi-center study of four academic healthcare institutions. Spirometry was performed in 113 adults admitted to general medicine wards with a physician diagnosis of asthma or COPD exacerbation. Two board-certified pulmonologists evaluated the spirometry tracings to determine the proportion of patients able to produce adequate quality spirometry data. Findings were interpreted to evaluate the utility of spirometry to confirm the presence of obstructive lung disease, according to the 2005 European Respiratory Society/American Thoracic Society recommendations. Results There was an almost perfect agreement for acceptability (κ = 0.92) and reproducibility (κ =0.93) of spirometry tracings. Three-quarters (73%) of the tests were interpreted by both pulmonologists as being of adequate quality. Of these adequate quality tests, 22% did not present objective evidence of obstructive lung disease. Obese patients (BMI ≥30 kg/m2) were more likely to produce spirometry tracings with no evidence of obstructive lung disease, compared to non-obese patients (33% vs. 8%, p = 0.007). Conclusions Adequate quality spirometry can be obtained in most hospitalized adults with a physician diagnosis of asthma or COPD exacerbation. Confirmatory spirometry could be a useful tool to help reduce overdiagnosis of obstructive lung disease, especially among obese

  18. Virtual respiratory system for interactive e-learning of spirometry

    Directory of Open Access Journals (Sweden)

    W. Tomalak

    2008-04-01

    Full Text Available Progress in computer simulation technology offers new possibilities for modern medicine. On one hand – virtual organs can help to create animal or human models for research, on the other hand – e-learning or distant learning through Internet is now possible. The aim of our work was to create a system for interactive learning of spirometry (SILS, enabling students or physicians to observe spirometric measurements (flow-volume modified by setting level and kind of abnormalities within the respiratory system. SILS is based on a virtual respiratory system presented previously in several papers. Its main features are: separation of the lungs and chest; anatomical division of the lungs; division of airway resistance into transmural pressure dependent (Rp and lung volume dependent (Rv parts. The one mathematical formula that represents Rp describes both flow limitation (forced expiration and dependence of Raw on lungs volume (small airflows. The output of system are spirometric parameters (as FEV1, FVC, FEV1%FVC and a flow–volume loop constructed according to results of simulation of forced expiration for the chosen abnormality kind and level. As a result – this system may be used in teaching process in medical schools and postgraduate education. We offer access to a basic version of SILS for students and physicians at: www.spirometry.ibib.waw.pl and www.zpigichp.edu.pl. As we expect feedback from users, it is possible to modify user interface or model features to comply with users' requests.

  19. Evaluation of plasma lactate concentration and base excess at the time of hospital admission as predictors of gastric necrosis and outcome and correlation between those variables in dogs with gastric dilatation-volvulus: 78 cases (2004-2009).

    Science.gov (United States)

    Beer, Kari A Santoro; Syring, Rebecca S; Drobatz, Kenneth J

    2013-01-01

    To determine the correlation between plasma lactate concentration and base excess at the time of hospital admission and evaluate each variable as a predictor of gastric necrosis or outcome in dogs with gastric dilatation-volvulus (GDV). Retrospective case series. 78 dogs. For each dog, various data, including plasma lactate concentration and base excess at the time of hospital admission, surgical or necropsy findings, and outcome, were collected from medical records. Gastric necrosis was identified in 12 dogs at the time of surgery and in 4 dogs at necropsy. Sixty-five (83%) dogs survived to hospital discharge, whereas 13 (17%) dogs died or were euthanized. Of the 65 survivors and 8 nonsurvivors that underwent surgery, gastric necrosis was detected in 8 and 4 dogs, respectively. Via receiver operating characteristic curve analysis, an initial plasma lactate concentration cutoff of 7.4 mmol/L was 82% accurate for predicting gastric necrosis (sensitivity, 50%; specificity, 88%) and 88% accurate for predicting outcome (sensitivity, 75%; specificity, 89%). Among all dogs, the correlation between initial plasma lactate concentration and base excess was significant, although base excess was a poor discriminator for predicting gastric necrosis or outcome (area under the receiver operating characteristic curve, 0.571 and 0.565, respectively). In dogs with GDV, plasma lactate concentration at the time of hospital admission was a good predictor of gastric necrosis and outcome. However, despite the correlation between initial base excess and plasma lactate concentration, base excess should not be used for prediction of gastric necrosis or outcome in those patients.

  20. CT-derived Biomechanical Metrics Improve Agreement Between Spirometry and Emphysema.

    Science.gov (United States)

    Bhatt, Surya P; Bodduluri, Sandeep; Newell, John D; Hoffman, Eric A; Sieren, Jessica C; Han, Meilan K; Dransfield, Mark T; Reinhardt, Joseph M

    2016-10-01

    Many patients with chronic obstructive pulmonary disease (COPD) have marked discordance between forced expiratory volume in 1 second (FEV1) and degree of emphysema on computed tomography (CT). Biomechanical differences between these patients have not been studied. We aimed to identify reasons for the discordance between CT and spirometry in some patients with COPD. Subjects with Global initiative for chronic Obstructive Lung Disease stages I-IV from a large multicenter study (The Genetic Epidemiology of COPD) were arranged by percentiles of %predicted FEV1 and emphysema on CT. Three categories were created using differences in percentiles: Catspir with predominant airflow obstruction/minimal emphysema, CatCT with predominant emphysema/minimal airflow obstruction, and Catmatched with matched FEV1 and emphysema. Image registration was used to derive Jacobian determinants, a measure of lung elasticity, anisotropy, and strain tensors, to assess biomechanical differences between groups. Regression models were created with the previously mentioned categories as outcome variable, adjusting for demographics, scanner type, quantitative CT-derived emphysema, gas trapping, and airway thickness (model 1), and after adding biomechanical CT metrics (model 2). Jacobian determinants, anisotropy, and strain tensors were strongly associated with FEV1. With Catmatched as control, model 2 predicted Catspir and CatCT better than model 1 (Akaike information criterion 255.8 vs. 320.8). In addition to demographics, the strongest independent predictors of FEV1 were Jacobian mean (β = 1.60,95%confidence intervals [CI] = 1.16 to 1.98; P spirometry, offering the potential for new insights into the linkage between regional parenchymal destruction and global decrement in lung function in patients with COPD. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. CT-derived Biomechanical Metrics Improve Agreement Between Spirometry and Emphysema

    Science.gov (United States)

    Bhatt, Surya P.; Bodduluri, Sandeep; Newell, John D.; Hoffman, Eric A.; Sieren, Jessica C.; Han, Meilan K.; Dransfield, Mark T.; Reinhardt, Joseph M.

    2016-01-01

    Rationale and Objectives Many COPD patients have marked discordance between FEV1 and degree of emphysema on CT. Biomechanical differences between these patients have not been studied. We aimed to identify reasons for the discordance between CT and spirometry in some patients with COPD. Materials and Methods Subjects with GOLD stage I–IV from a large multicenter study (COPDGene) were arranged by percentiles of %predicted FEV1 and emphysema on CT. Three categories were created using differences in percentiles: Catspir with predominant airflow obstruction/minimal emphysema, CatCT with predominant emphysema/minimal airflow obstruction, and Catmatched with matched FEV1 and emphysema. Image registration was used to derive Jacobian determinants, a measure of lung elasticity, anisotropy and strain tensors, to assess biomechanical differences between groups. Regression models were created with the above categories as outcome variable, adjusting for demographics, scanner type, quantitative CT-derived emphysema, gas trapping, and airway thickness (Model 1), and after adding biomechanical CT metrics (Model 2). Results Jacobian determinants, anisotropy and strain tensors were strongly associated with FEV1. With Catmatched as control, Model 2 predicted Catspir and CatCT better than Model 1 (Akaike Information Criterion, AIC 255.8 vs. 320.8). In addition to demographics, the strongest independent predictors of FEV1 were Jacobian mean (β= 1.60,95%CI = 1.16 to 1.98; p<0.001), coefficient of variation (CV) of Jacobian (β= 1.45,95%CI = 0.86 to 2.03; p<0.001) and CV strain (β= 1.82,95%CI = 0.68 to 2.95; p = 0.001). CVs of Jacobian and strain are both potential markers of biomechanical lung heterogeneity. Conclusions CT-derived measures of lung mechanics improve the link between quantitative CT and spirometry, offering the potential for new insights into the linkage between regional parenchymal destruction and global decrement in lung function in COPD patients. PMID:27055745

  2. Polynomial estimation of the smoothing splines for the new Finnish reference values for spirometry.

    Science.gov (United States)

    Kainu, Annette; Timonen, Kirsi

    2016-07-01

    Background Discontinuity of spirometry reference values from childhood into adulthood has been a problem with traditional reference values, thus modern modelling approaches using smoothing spline functions to better depict the transition during growth and ageing have been recently introduced. Following the publication of the new international Global Lung Initiative (GLI2012) reference values also new national Finnish reference values have been calculated using similar GAMLSS-modelling, with spline estimates for mean (Mspline) and standard deviation (Sspline) provided in tables. The aim of this study was to produce polynomial estimates for these spline functions to use in lieu of lookup tables and to assess their validity in the reference population of healthy non-smokers. Methods Linear regression modelling was used to approximate the estimated values for Mspline and Sspline using similar polynomial functions as in the international GLI2012 reference values. Estimated values were compared to original calculations in absolute values, the derived predicted mean and individually calculated z-scores using both values. Results Polynomial functions were estimated for all 10 spirometry variables. The agreement between original lookup table-produced values and polynomial estimates was very good, with no significant differences found. The variation slightly increased in larger predicted volumes, but a range of -0.018 to +0.022 litres of FEV1 representing ± 0.4% of maximum difference in predicted mean. Conclusions Polynomial approximations were very close to the original lookup tables and are recommended for use in clinical practice to facilitate the use of new reference values.

  3. Quantitative computed tomography versus spirometry in predicting air leak duration after major lung resection for cancer.

    Science.gov (United States)

    Ueda, Kazuhiro; Kaneda, Yoshikazu; Sudo, Manabu; Mitsutaka, Jinbo; Li, Tao-Sheng; Suga, Kazuyoshi; Tanaka, Nobuyuki; Hamano, Kimikazu

    2005-11-01

    Emphysema is a well-known risk factor for developing air leak or persistent air leak after pulmonary resection. Although quantitative computed tomography (CT) and spirometry are used to diagnose emphysema, it remains controversial whether these tests are predictive of the duration of postoperative air leak. Sixty-two consecutive patients who were scheduled to undergo major lung resection for cancer were enrolled in this prospective study to define the best predictor of postoperative air leak duration. Preoperative factors analyzed included spirometric variables and area of emphysema (proportion of the low-attenuation area) that was quantified in a three-dimensional CT lung model. Chest tubes were removed the day after disappearance of the air leak, regardless of pleural drainage. Univariate and multivariate proportional hazards analyses were used to determine the influence of preoperative factors on chest tube time (air leak duration). By univariate analysis, site of resection (upper, lower), forced expiratory volume in 1 second, predicted postoperative forced expiratory volume in 1 second, and area of emphysema ( 10%) were significant predictors of air leak duration. By multivariate analysis, site of resection and area of emphysema were the best independent determinants of air leak duration. The results were similar for patients with a smoking history (n = 40), but neither forced expiratory volume in 1 second nor predicted postoperative forced expiratory volume in 1 second were predictive of air leak duration. Quantitative CT is superior to spirometry in predicting air leak duration after major lung resection for cancer. Quantitative CT may aid in the identification of patients, particularly among those with a smoking history, requiring additional preventive procedures against air leak.

  4. Introduction of spirometry into clinical practice in Georgetown, Guyana: quality and diagnostic outcomes.

    Science.gov (United States)

    Johnston, J C; Rempel, C; Sanders, C; Piggott, E; Maxwell, Y; Jaipersaud, K; Luknauth, R; Persaud, D; Rambaran, M; Levy, R D

    2016-09-01

    Georgetown Public Hospital Corporation (GPHC), a 600-bed publicly funded referral hospital in Georgetown, Guyana. To assess spirometry quality and diagnostic outcomes 2 years after the introduction of spirometry into routine clinical practice at GPHC. We performed a retrospective review of 476 consecutive spirometry assessments performed from November 2013 to November 2015. We assessed the proportion and trend of spirometry tests meeting acceptability criteria, along with diagnostic interpretations and spirometry laboratory referral patterns. Overall, 80.4% of the 454 initial spirometry measurements on unique patients met the acceptability criteria, with no significant change in the proportion of acceptable spirometry over the study period (P = 0.450). Of the 369 (81.3%) first tests considered interpretable, 139 (30.6%) were normal, 151 (33.3%) were obstructive, 54 (11.9%) were suggestive of a restrictive pattern, 25 (5.5%) were suggestive of a mixed disorder and 119 (26.2%) tests met the definition of reversibility. Over a 2-year period, high-quality spirometry was performed in GPHC, a publicly funded hospital in a middle-income country with no pre-existing specialised respiratory service.

  5. Lack of spirometry use in Danish patients initiating medication targeting obstructive lung disease

    DEFF Research Database (Denmark)

    Koefoed, Mette; Christensen, René Depont; Søndergaard, Jens

    2012-01-01

    Research indicates that a large proportion of patients using medication targeting obstructive lung disease have no history of spirometry testing.......Research indicates that a large proportion of patients using medication targeting obstructive lung disease have no history of spirometry testing....

  6. Mismatch between asthma symptoms and spirometry: implications for managing asthma in children.

    Science.gov (United States)

    Schifano, Elizabeth D; Hollenbach, Jessica P; Cloutier, Michelle M

    2014-11-01

    To examine the concordance between spirometry and asthma symptoms in assessing asthma severity and beginning therapy by the general pediatrician. Between 2008 and 2012, spirometry testing was satisfactorily performed in 894 children (ages 5-19 years) whose asthma severity had been determined by their pediatrician using asthma guideline-based clinical criteria. Spirometry-determined asthma severity using national asthma guidelines and clinician-determined asthma severity were compared for concordance using weighted Kappa coefficients. Thirty percent of participants had clinically determined intermittent asthma; 32%, 33%, and 5% had mild, moderate, and severe, persistent asthma, respectively. Increasing disease severity was associated with decreases in the forced expiratory volume in 1 second/forced vital capacity (FVC) ratio (P spirometry-determined severity. Concordance was 0.16 (95% CI 0.10, 0.23), and when adjusted for bias and prevalence, was 0.20 (95% CI 0.17, 0.23). When accounting for age, sex, exposure to smoke, and insurance type, only spirometry-determined asthma severity was a significant predictor of agreement (P spirometry-determined severity increased. Concordance between spirometry and asthma symptoms in determining asthma severity is low even when guideline-based clinical assessment tools are used. Because appropriate therapy reduces asthma morbidity and is guided by disease severity, results from spirometry testing could better guide pediatricians in determining appropriate therapy for their patients with asthma. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Disease Severity Prediction by Spirometry in Adults with Visceral Leishmaniasis from Minas Gerais, Brazil.

    Science.gov (United States)

    Maia, Isabel A; Bezerra, Frank S; Albuquerque, André Luis Pereira de; Andrade, Heitor F; Nicodemo, Antonio C; Amato, Valdir S

    2017-02-08

    Visceral leishmaniasis (VL) is associated with interstitial pneumonitis according to histology and radiology reports. However, studies to address the functional impact on respiratory function in patients are lacking. We assessed pulmonary function using noninvasive spirometry in a cross-sectional study of hospitalized adult VL patients from Minas Gerais, Brazil, without unrelated lung conditions or acute infections. Lung conditions were graded as normal, restrictive, obstructive, or mixed patterns, according to Brazilian consensus standards for spirometry. To control for regional patterns of lung function, we compared spirometry of patients with regional paired controls. Spirometry detected abnormal lung function in most VL patients (70%, 14/20), usually showing a restrictive pattern, in contrast to regional controls and the standards for normal tests. Alterations in spirometry measurements correlated with hypoalbuminemia, the only laboratory value indicative of severity of parasitic disease. Abnormalities did not correlate with unrelated factors such as smoking or occupation. Clinical data including pulmonary symptoms and duration of therapy were also unrelated to abnormal spirometry findings. We conclude that the severity of VL is correlated with a restrictive pattern of lung function according to spirometry, suggesting that there may be interstitial lung involvement in VL. Further studies should address whether spirometry could serve as an index of disease severity in the management of VL. © The American Society of Tropical Medicine and Hygiene.

  8. Spirometry for patients in hospital and one month after admission with an acute exacerbation of COPD

    Science.gov (United States)

    Rea, Harry; Kenealy, Timothy; Adair, Jacqui; Robinson, Elizabeth; Sheridan, Nicolette

    2011-01-01

    Aim To assess whether spirometry done in hospital during an admission for an acute exacerbation of chronic obstructive pulmonary disease (AECOPD) is clinically useful for long-term management. Methods Patients admitted to hospital with a clinical diagnosis of AECOPD had spirometry post-bronchodilator at discharge and approximately 4 weeks later. Results Spirometry was achieved in less than half of those considered to have AECOPD. Of 49 patients who had spirometry on both occasions, 41 met the GOLD criteria for COPD at discharge and 39 of these met the criteria at 1 month. For the 41, spirometry was not statistically different between discharge and 1 month but often crossed arbitrary boundaries for classification of severity based on FEV1. The eight who did not meet GOLD criteria at discharge were either misclassified due to comorbidities that reduce FVC, or they did not have COPD as a cause of their hospital admission. Conclusion Spirometry done in hospital at the time of AECOP is useful in patients with a high pre-test probability of moderate-to-severe COPD. Small changes in spirometry at 1 month could place them up or down one grade of severity. Spirometry at discharge may be useful to detect those who warrant further investigation. PMID:22069364

  9. Implications of the Transition From Zapletal to GLI Reference Values for Spirometry

    NARCIS (Netherlands)

    Raaijmakers, Lena; Zwitserloot, Annelies; Merkus, Peter; Gappa, Monika

    The current standard for monitoring lung function in children with asthma is spirometry. In Europe, results of these lung function tests have been related to Zapletal reference values published in 1977. Recently, the Global Lung Function Initiative (GLI) published predicted values of spirometry for

  10. Semi-Quantitative Assessment of the Health Risk of Occupational Exposure to Chemicals and Evaluation of Spirometry Indices on the Staff of Petrochemical Industry

    Directory of Open Access Journals (Sweden)

    Hajar Dazi

    2017-01-01

    Full Text Available Background & Aims of the Study: Petrochemical industry is an important industry in the economic development of the country that causes employees have exposure with several kinds of contamination. The aim of this study was Semi-quantitative assessment of the health risk of occupational exposure to chemical materials and investigation of spirometry indices between employees of petrochemical industry. Material & Methods: This cross-sectional study was conducted in one of the petrochemical industry complex in a special area of Assaluyeh in Iran in 2016. Health risk assessment of exposure to harmful chemical agents was performed in all of units and during three stages (identification of harmful material, determination of hazard rate of the chemical material, exposure rate and estimate of risk rate. Spirometry indices were measured using spirometry. Results: The results of chemical materials risk assessment showed that Raffinate in Butadiene unit has identified the highest amount of risk rank among 27 chemical materials in investigated units. In comparison with spirometry indices in Olefine unit between age with FVC parameter and history work with FVC and FEV1 parameters has observed a significant and negative correlation (P<0.05. Conclusion: The results of risk assessment in all of the petrochemical units showed that 48.14% of materials were at low risk level, 29.62% medium risk, 18.51% high risk and 3.7% had very high risk level. The variables affecting on spirometry employees such as age and work experience play an important role in reducing the pulmonary function tests in exposed subjects.

  11. Differences in the use of spirometry between rural and urban primary care centers in Spain.

    Science.gov (United States)

    Márquez-Martín, Eduardo; Soriano, Joan B; Rubio, Myriam Calle; Lopez-Campos, Jose Luis

    2015-01-01

    The aim of this study is to evaluate the ability and practice of spirometry, training of technicians, and spirometry features in primary care centers in Spain, evaluating those located in a rural environment against those in urban areas. An observational cross-sectional study was conducted in 2012 by a telephone survey in 970 primary health care centers in Spain. The centers were divided into rural or urban depending on the catchment population. The survey contacted technicians in charge of spirometry and consisted of 36 questions related to the test that included the following topics: center resources, training doctors and technicians, using the spirometer, bronchodilator test, and the availability of spirometry and maintenance. Although the sample size was achieved in both settings, rural centers (RCs) gave a lower response rate than urban centers (UCs). The number of centers without spirometry in rural areas doubled those in the urban areas. Most centers had between one and two spirometers. However, the number of spirometry tests per week was significantly lower in RCs than in UCs (4 [4.1%] vs 6.9 [5.7%], Pspirometries was higher in RCs than in UCs (209 [73.0%] vs 207 [64.2%], P=0.003). RCs were more satisfied with the spirometries (7.8 vs 7.6, P=0.019) and received more training course for interpreting spirometry (41.0% vs 33.2%, P=0.004). The performance of the bronchodilator test showed a homogeneous measure in different ways. The spirometer type and the reference values were unknown to the majority of respondents. This study shows the differences between primary care RCs and UCs in Spain in terms of performing spirometry. The findings in the present study can be used to improve the performance of spirometry in these areas.

  12. Spirometry effects on conventional and multiple flow exhaled nitric oxide in children.

    Science.gov (United States)

    Eckel, Sandrah P; Linn, William S; Salam, Muhammad T; Bastain, Theresa M; Zhang, Yue; Rappaport, Edward B; Liu, Meng; Berhane, Kiros

    2015-03-01

    Clinical and research settings often require sequencing multiple respiratory tests in a brief visit. Guidelines recommend measuring the concentration of exhaled nitric oxide (FeNO) before spirometry, but evidence for a spirometry carryover effect on FeNO is mixed. Only one study has investigated spirometry carryover effects on multiple flow FeNO analysis. The objective of this study was to evaluate evidence for carryover effects of recent spirometry on three exhaled NO summary measures: FeNO at 50 ml/s, airway wall NO flux [J'awNO] and alveolar NO concentration [CANO] in a population-based sample of schoolchildren. Participants were 1146 children (191 with asthma), ages 12-15, from the Southern California Children's Health Study who performed spirometry and multiple flow FeNO on the same day. Approximately, half the children performed spirometry first. Multiple linear regression was used to estimate differences in exhaled NO summary measures associated with recent spirometry testing, adjusting for potential confounders. In the population-based sample, we found no evidence of spirometry carryover effects. However, for children with asthma, there was a suggestion that exhaled NO summary measures assessed ≤6 min after spirometry were lower (FeNO: 25.8% lower, 95% CI: -6.2%, 48.2%; J'awNO: 15.1% lower 95% CI: -26.5%, 43.0%; and CANO 0.43 parts per billion lower, 95% CI: -0.12, 0.98). In clinical settings, it is prudent to assess multiple flow FeNO before spirometry. In studies of healthy subjects, it may not be necessary to assess FeNO first.

  13. Use of telehealth technology for home spirometry after lung transplantation: a randomized controlled trial.

    Science.gov (United States)

    Sengpiel, Juliane; Fuehner, Thomas; Kugler, Christiane; Avsar, Murat; Bodmann, Isabelle; Boemke, Annelies; Simon, Andre; Welte, Tobias; Gottlieb, Jens

    2010-12-01

    Complications often occur during the early phase after lung transplantation, and rapid diagnosis is vital. Home spirometry is used to detect early changes in graft function. Bluetooth-equipped cell phones are easy to use and facilitate data transfer from home spirometry. To explore use of home spirometry with Bluetooth data transfer in outpatient lung transplant recipients. Single-center prospective randomized controlled trial. Intervention-Fifty-six patients were randomized either to home spirometry with data transfer via Bluetooth-equipped cell phones or to home spirometry alone before discharge after lung transplantation. In the Bluetooth group, results were transferred to a database capable of generating alarm messages. Time from onset of symptoms to physician consultation during the first 6 months after lung transplantation was the primary end point. Adherence to home spirometry was 97.2% in the Bluetooth group and 95.3% in the home spirometry alone group (P = .73). Median time to first consultation (P = .60) and frequency of consultation (P = .06) did not differ significantly in the 2 groups. Mean scores on the Hospital Anxiety and Depression Scale were lower in patients in the Bluetooth group (1.5; range, 0.0-4.0) than in the home spirometry alone group (4.0; range, 2.0-6.0; P = .04). Home spirometry with data transfer is feasible and safe in lung transplant recipients. Compared with home spirometry alone, additional data transfer was equally effective regarding the time interval from symptom onset to consultation. Patients in the Bluetooth group reported less anxiety, which may improve emotional well-being.

  14. [The spirometry figures of bronchoobstructive syndrome in concomitant intestinal parasitosis].

    Science.gov (United States)

    Aliyev, K; Aliyeva, G; Gadjiyeva, N

    2010-02-01

    The aim of research is to study of the spirometry figures of bronchoobstructive syndrome in concomitant intestinal parasitosis. There are 81 patients aged from 5 to 61 years (male 43, female 38) were examined. The patients were divided into 2 groups: 1 group - patients treated only with bronchodilator therapy (14 patients with protozoa, 14 - with helminth, 12 - with combination of parasitosis); 2 group - patients treated with bronchodilator therapy in common with anti-parasitic therapy (14 patients with protozoa, 17 - with helminth, 10 - with combination of parasitosis). There are 22 patients with bronchoobstructive syndrome without parasites were included in control group. Functional disorders at the initial examination are not significantly distinguished between patients with protozoa, helminth, with combined parasitosis and patients without parasites. Considerable differences manifested in dynamics after treatment: only bronchodilator therapy of patients infected with parasites is not lead to sufficient increase of the indices of external respiration function, even the decreasing of the most parameters were observed in patients with helminth. The least growth of spirometric indices were observed in patients from group 1 - 2,17/ 5,09% predicted volumes (-6,81min; 10,54max), the highest growth were observed in patients from group 2 - 20,26/ 12,45% p.v. (2,77min; 43,85max). The spirographic indicators increase after treatment in the control group was more moderate in comparison with 1 and 2 groups - 5,96/ 2,97% p.v. (0,39min; 9,59max). Thus, using antiparasitic therapy in common with bronchodilator therapy in treatment of patients with intestinal parasitosis (group 2) is lead to the reliably significant positive dynamic of spirometry parameters in comparison not only to 1 group (<0,05 for many parameters) but also to control group (<0,01 for many parameters).

  15. Use of spirometry among chest physicians and primary care physicians in India.

    Science.gov (United States)

    Vanjare, Nitin; Chhowala, Sushmeeta; Madas, Sapna; Kodgule, Rahul; Gogtay, Jaideep; Salvi, Sundeep

    2016-07-07

    Although spirometry is the gold-standard diagnostic test for obstructive airways diseases, it remains poorly utilised in clinical practice. We aimed to investigate the use of spirometry across India, the change in its usage over a period of time and to understand the reasons for its under-utilisation. Two nationwide surveys were conducted in the years 2005 and 2013, among four groups of doctors: chest physicians (CPs), general physicians (GenPs), general practitioners (GPs) and paediatricians (Ps). A total of 1,000 physicians from each of the four groups were randomly selected from our database in the years 2005 and 2013. These surveys were conducted in 52 cities and towns across 15 states in India. A questionnaire was administered to the physicians, which captured information about their demographic details, type of practice and use of spirometry. The overall response rates of the physicians in 2005 and 2013 were 42.8% and 54.9%, respectively. Spirometry was reported to be used by 55% CPs, 20% GenPs, 10% GPs and 5% Ps in 2005, and this increased by 30.9% among CPs (P value spirometry varied between 2005 and 2013. In all, 32.2% of physicians were unaware of which predicted equation they were using. The use of spirometry in India is low, although it seems to have improved over the years. The reasons identified in this study for under-utilisation should be used to address initiatives to improve the use of spirometry in clinical practice.

  16. Telemedicine spirometry training and quality assurance program in primary care centers of a public health system.

    Science.gov (United States)

    Marina Malanda, Nuria; López de Santa María, Elena; Gutiérrez, Asunción; Bayón, Juan Carlos; Garcia, Larraitz; Gáldiz, Juan B

    2014-04-01

    Forced spirometry is essential for diagnosing respiratory diseases and is widely used across levels of care. However, several studies have shown that spirometry quality in primary care is not ideal, with risks of misdiagnosis. Our objective was to assess the feasibility and performance of a telemedicine-based training and quality assurance program for forced spirometry in primary care. The two phases included (1) a 9-month pilot study involving 15 centers, in which spirometry tests were assessed by the Basque Office for Health Technology Assessment, and (2) the introduction of the program to all centers in the Public Basque Health Service. Technicians first received 4 h of training, and, subsequently, they sent all tests to the reference laboratory using the program. Quality assessment was performed in accordance with clinical guidelines (A and B, good; C-F, poor). In the first phase, 1,894 spirometry tests were assessed, showing an improvement in quality: acceptable quality tests increased from 57% at the beginning to 78% after 6 months and 83% after 9 months (passessed after the inclusion of 36 additional centers, maintaining the positive trend (61%, 87%, and 84% at the same time points; pquality of spirometry tests improved in all centers. (2) The program provides a tool for transferring data that allows monitoring of its quality and training of technicians who perform the tests. (3) This approach is useful for improving spirometry quality in the routine practice of a public health system.

  17. Risk of COPD with obstruction in active smokers with normal spirometry and reduced diffusion capacity.

    Science.gov (United States)

    Harvey, Ben-Gary; Strulovici-Barel, Yael; Kaner, Robert J; Sanders, Abraham; Vincent, Thomas L; Mezey, Jason G; Crystal, Ronald G

    2015-12-01

    Smokers are assessed for chronic obstructive pulmonary disease (COPD) using spirometry, with COPD defined by the Global Initiative for Chronic Obstructive Lung Disease (GOLD) as airflow limitation that is not fully reversible with bronchodilators. There is a subset of smokers with normal spirometry (by GOLD criteria), who have a low diffusing capacity of the lung for carbon monoxide (DLCO), a parameter linked to emphysema and small airway disease. The natural history of these "normal spirometry/low DLCO" smokers is unknown.From a cohort of 1570 smokers in the New York City metropolitian area, all of whom had normal spirometry, two groups were randomly selected for lung function follow-up: smokers with normal spirometry/normal DLCO (n=59) and smokers with normal spirometry/low DLCO (n=46). All had normal history, physical examination, complete blood count, urinalysis, HIV status, α1-antitrypsin level, chest radiography, forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC ratio and total lung capacity. Throughout the study, all continued to be active smokers.In the normal spirometry/normal DLCO group assessed over 45±20 months, 3% developed GOLD-defined COPD. In contrast, in the normal spirometry/low DLCO group, followed over 41±31 months, 22% developed GOLD-defined COPD.Despite appearing "normal" according to GOLD, smokers with normal spirometry but low DLCO are at significant risk of developing COPD with obstruction to airflow. Copyright ©ERS 2015.

  18. Excess Entropy and Diffusivity

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. Excess Entropy and Diffusivity. Excess entropy scaling of diffusivity (Rosenfeld,1977). Analogous relationships also exist for viscosity and thermal conductivity.

  19. The reliability and utility of spirometry performed on people with asthma in community pharmacies.

    Science.gov (United States)

    Lei Burton, Deborah; LeMay, Kate S; Saini, Bandana; Smith, Lorraine; Bosnic-Anticevich, Sinthia; Southwell, Phillipa; Cooke, Julie; Emmerton, Lynne; Stewart, Kay; Krass, Ines; Reddel, Helen; Armour, Carol

    2015-01-01

    To investigate the reliability and the utility of spirometry generated by community pharmacists participating in two large asthma intervention trials of 892 people. The Pharmacy Asthma Care Program (PACP) and the Pharmacy Asthma Management Service (PAMS) involved up to four visits to the pharmacy over 6 months for counseling and goal setting. Pharmacists performed spirometry according to ATS/ERS guidelines to inform management. The proportion of A-E, F quality tests, as per EasyOne QC grades, were recorded. Lung function results between visits and for participants referred/not referred to their general practitioner on the basis of spirometry were compared. Complete data from 2593 spirometry sessions were recorded, 68.5% of spirometry sessions achieved three acceptable tests with between-test repeatability of 150 ml or less (A or B quality), 96% of spirometry sessions included at least one test that met ATS/ERS acceptability criteria. About 39.1% of participants had FEV1/FVC values below the lower limit of normal (LNN), indicating a respiratory obstruction. As a result of the service, there was a significant increase in FEV1 and FEV1/FVC and asthma control. Lung function values were significantly poorer for participants referred to their general practitioner, compared with those not referred, on the basis of spirometry. Community pharmacists are able to reliably achieve spirometry results meeting ATS/ERS guidelines in people with asthma. Significant improvements in airway obstruction were demonstrated with the pharmacy services. Pharmacists interpreted lung function results to identify airway obstruction for referral, making this a useful technique for review of people with asthma in the community.

  20. Correlation between spirometry values and pulmonary artery pressure in young healthy subjects.

    Science.gov (United States)

    Grossman, Alon; Benderly, Michal; Prokupetz, Alex; Gordon, Barak; Kalter-Leibovici, Ofra

    2014-03-01

    Pulmonary hypertension is frequently associated with parenchymal lung disease. We evaluated the association between spirometry values and pulmonary artery systolic pressure (PASP) in young subjects without lung disease : We studied applicants to the Israeli Air Force, who undergo routine evaluation that includes resting spirometry and echocardiography. Applicants with overt lung disease were excluded. All echocardiographic studies performed in the years 1994 through 2010 (n = 6,598) were screened, and files that included PASP and spirometry values were analyzed for the association between PASP and FVC, FEV1, FEV1/FVC, peak expiratory flow, and forced expiratory flow during the middle half of the FVC maneuver. Of the 647 air force applicants who underwent echocardiography in which PASP was measurable and had spirometry data, 607 (94%) were male, and their average age was 18.16 ± 0.73 years. Mean PASP was 26.4 ± 5.2 mm Hg (range 10-41 mm Hg). None of the spirometry values significantly correlated with PASP. PASP in young healthy subjects is not significantly associated with spirometry values. Lung mechanics probably do not contribute significantly to PASP in this population.

  1. Impulse Oscillometry and Spirometry Small-Airway Parameters in Mild to Moderate Bronchiectasis.

    Science.gov (United States)

    Guan, Wei-Jie; Yuan, Jing-Jing; Gao, Yong-Hua; Li, Hui-Min; Zheng, Jin-Ping; Chen, Rong-Chang; Zhong, Nan-Shan

    2016-11-01

    Both impulse oscillometry and spirometry can reflect small-airway disorders. The objective of this work was to investigate the diagnostic value of impulse oscillometry and spirometry small-airway parameters and their correlation with radiology, disease severity, and sputum bacteriology in mild to moderate bronchiectasis (bronchiectasis severity index spirometry, and sputum culture were performed. Correlation between small-airway parameters and clinical indices was determined, adjusting for age, sex, body mass index, and smoking history. Sensitivity analyses were repeated when excluding subjects with bronchiectasis severity index ≥9 or HRCT score ≥13. Impulse oscillometry and spirometry small-airway parameters could discriminate mild to moderate bronchiectasis from healthy subjects and correlated significantly with HRCT score and the number of bronchiectatic lobes and the bronchiectasis severity index (all P Spirometry, but not impulse oscillometry, small-airway parameters differed statistically between subjects with isolated peripheral-airway bronchiectasis and those with peripheral plus central-airway bronchiectasis (all P spirometry small-airway parameters have similar diagnostic value in reflecting peripheral-airway disorders and correlate with the HRCT scores, the bronchiectasis severity index, and the number of bronchiectatic lobes in mild to moderate bronchiectasis. Assessment of small-airway parameters should be incorporated in future lung function investigations in bronchiectasis. Copyright © 2016 by Daedalus Enterprises.

  2. Spirometry reference equations for central European populations from school age to old age.

    Directory of Open Access Journals (Sweden)

    Mascha K Rochat

    Full Text Available BACKGROUND: Spirometry reference values are important for the interpretation of spirometry results. Reference values should be updated regularly, derived from a population as similar to the population for which they are to be used and span across all ages. Such spirometry reference equations are currently lacking for central European populations. OBJECTIVE: To develop spirometry reference equations for central European populations between 8 and 90 years of age. MATERIALS: We used data collected between January 1993 and December 2010 from a central European population. The data was modelled using "Generalized Additive Models for Location, Scale and Shape" (GAMLSS. RESULTS: The spirometry reference equations were derived from 118'891 individuals consisting of 60'624 (51% females and 58'267 (49% males. Altogether, there were 18'211 (15.3% children under the age of 18 years. CONCLUSION: We developed spirometry reference equations for a central European population between 8 and 90 years of age that can be implemented in a wide range of clinical settings.

  3. Prediction equations for spirometry in four- to six-year-old children.

    Science.gov (United States)

    França, Danielle Corrêa; Camargos, Paulo Augusto Moreira; Jones, Marcus Herbert; Martins, Jocimar Avelar; Vieira, Bruna da Silva Pinto Pinheiro; Colosimo, Enrico Antônio; de Mendonça, Karla Morganna Pereira Pinto; Borja, Raíssa de Oliveira; Britto, Raquel Rodrigues; Parreira, Verônica Franco

    2016-01-01

    To generate prediction equations for spirometry in 4- to 6-year-old children. Forced vital capacity, forced expiratory volume in 0.5s, forced expiratory volume in one second, peak expiratory flow, and forced expiratory flow at 25-75% of the forced vital capacity were assessed in 195 healthy children residing in the town of Sete Lagoas, state of Minas Gerais, Southeastern Brazil. The least mean squares method was used to derive the prediction equations. The level of significance was established as p<0.05. Overall, 85% of the children succeeded in performing the spirometric maneuvers. In the prediction equation, height was the single predictor of the spirometric variables as follows: forced vital capacity=exponential [(-2.255)+(0.022×height)], forced expiratory volume in 0.5s=exponential [(-2.288)+(0.019×height)], forced expiratory volume in one second=exponential [(-2.767)+(0.026×height)], peak expiratory flow=exponential [(-2.908)+(0.019×height)], and forced expiratory flow at 25-75% of the forced vital capacity=exponential [(-1.404)+(0.016×height)]. Neither age nor weight influenced the regression equations. No significant differences in the predicted values for boys and girls were observed. The predicted values obtained in the present study are comparable to those reported for preschoolers from both Brazil and other countries. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  4. Longitudinal spirometry among patients in a treatment program for community members with World Trade Center (WTC)-related illness

    Science.gov (United States)

    Liu, Mengling; Qian, Meng; Cheng, Qinyi; Berger, Kenneth I.; Shao, Yongzhao; Turetz, Meredith; Kazeros, Angeliki; Parsia, Sam; Goldring, Roberta M.; Fernandez-Beros, Maria Elena; Marmor, Michael; Reibman, Joan

    2013-01-01

    Objective The course of lung function in community members exposed to World Trade Center (WTC) dust and fumes remains undefined. We studied longitudinal spirometry among patients in the WTC Environmental Health Center (WTCEHC) treatment program. Methods Observational study of 946 WTCEHC patients with repeated spirometry measures analyzed on the population as a whole and stratified by smoking status, initial spirometry pattern and WTC-related exposure category. Results Improvement in forced expiratory volume (FVC; 54.4 ml/year; 95% CI: 45.0-63.8) and forced expiratory volume in one second (FEV1; 36.8 ml/year; 95% CI: 29.3-44.3) was noted for the population as a whole. Heavy smokers did not improve. Spirometry changes differed depending on initial spirometry pattern and exposure category. Conclusions These data demonstrate spirometry improvement in select populations suggesting reversibility in airway injury and reinforcing the importance of continued treatment. PMID:22995806

  5. Effectiveness of the Spirometry 360 Quality Improvement Program for Improving Asthma Care: A Cluster Randomized Trial.

    Science.gov (United States)

    Mangione-Smith, Rita; Zhou, Chuan; Corwin, Michael J; Taylor, James A; Rice, Fiona; Stout, James W

    To determine the effectiveness of the Spirometry 360 distance learning quality improvement (QI) program for enhancing the processes and outcomes of care for children with asthma. Cluster randomized controlled trial involving 25 matched pairs of pediatric primary care practices. Practices were recruited from 2 practice-based research networks: the Slone Center Office-based Research Network at Boston University, Boston, Mass, and the Puget Sound Pediatric Research Network, Seattle, Wash. Study participants included providers from one of the 50 enrolled pediatric practices and 626 of their patients with asthma. Process measures assessed included spirometry test quality and appropriate prescription of asthma controller medications. Outcome measures included asthma-specific health-related quality of life, and outpatient, emergency department, and inpatient utilization for asthma. At baseline, 25.4% of spirometry tests performed in control practices and 50.4% of tests performed in intervention practices were of high quality. During the 6-month postintervention period, 28.7% of spirometry tests performed in control practices and 49.9% of tests performed in intervention practices were of high quality. The adjusted difference-of-differences analysis revealed no intervention effect on spirometry test quality. Adjusted differences-of-differences analysis also revealed no intervention effect on appropriate use of controller medications or any of the parent- or patient-reported outcomes examined. In this study, the Spirometry 360 distance learning QI program was ineffective in improving spirometry test quality or parent- or patient-reported outcomes. QI programs like the one assessed here may need to focus on practices with lower baseline performance levels or may need to be tailored for those with higher baseline performance. Copyright © 2017 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  6. Spirometry is underused in the diagnosis and monitoring of patients with chronic obstructive pulmonary disease (COPD)

    Science.gov (United States)

    Yu, Wai Cho; Fu, Sau Nga; Tai, Emily Lai-bun; Yeung, Yiu Cheong; Kwong, Kwok Chu; Chang, Yui; Tam, Cheuk Ming; Yiu, Yuk Kwan

    2013-01-01

    Spirometry is important in the diagnosis and management of chronic obstructive pulmonary disease (COPD), yet it is a common clinical observation that it is underused though the extent is unclear. This survey aims to examine the use of spirometry in the diagnosis and management of COPD patients in a district in Hong Kong. It is a cross-sectional survey involving four clinic settings: hospital-based respiratory specialist clinic, hospital-based mixed medical specialist clinic, general outpatient clinic (primary care), and tuberculosis and chest clinic. Thirty physician-diagnosed COPD patients were randomly selected from each of the four clinic groups. All of them had a forced expiratory volume in 1 second (FEV1) to forced vital capacity ratio less than 0.70 and had been followed up at the participating clinic for at least 6 months for COPD treatment. Of 126 patients who underwent spirometry, six (4.8%) did not have COPD. Of the 120 COPD patients, there were 111 males and mean post-bronchodilator FEV1 was 46.2% predicted. Only 22 patients (18.3%) had spirometry done during diagnostic workup, and 64 patients (53.3%) had spirometry done ever. The only independent factor predicting spirometry done ever was absence of old pulmonary tuberculosis and follow-up at respiratory specialist clinic. Age, sex, smoking status, comorbidities, duration of COPD, percentage predicted FEV1, body mass index, 6-minute walking distance, and Medical Research Council dyspnea score were not predictive. We conclude that spirometry is underused in general but especially by nonrespiratory physicians and family physicians in the management of COPD patients. More effort at educating the medical community is urgently needed. PMID:24009418

  7. Feasibility of spirometry in primary care to screen for COPD: a pilot study.

    Science.gov (United States)

    Giraud, Violaine; Beauchet, Alain; Gomis, Thierry; Chinet, Thierry

    2016-01-01

    COPD is a frequent but underdiagnosed disease whose diagnosis relies on the spirometric demonstration of bronchial obstruction. Spirometry use by general practitioners could represent the first line in COPD diagnosis. Because duration of spirometry is retarding its development in primary care, we decided to measure the time it requires in the primary-care context in France. Ten volunteer general practitioners were trained during two 3-hour theoretical and practical continuing education sessions. Then, from October 2013 to May 2014, they included patients without any known respiratory disease but at risk of developing COPD (age: ≥40 years, smoker: ≥20 pack-years). The duration of spirometry and its quality were evaluated according to the following acceptability criteria: 1) expiration ≥6 seconds or reaching a plateau; 2) good start with an early peak flow, curve peaked on top and not flat; 3) no artifacts; and 4) reproducibility criteria, ie, forced expiratory volume in 1 second and forced vital capacity differences between the two best spirometry curves ≤0.15 L. Quality of the spirograms was defined as optimal when all the criteria were met and acceptable when all the criteria were satisfied except the reproducibility criterion, otherwise, it was unacceptable. For the 152 patients included, the 142 assessable spirometries lasted for 15.2±5.9 minutes. Acceptability criteria 1-3, respectively, were satisfied for 90.1%, 89.4%, and 91.5% of patients and reproducibility criterion 4 for 56.3%. Quality was considered optimal for 58.5% of the curves and acceptable for 30.2%. The duration of spirometry renders it poorly compatible with the current primary-care practice in France other than for dedicated consultations. Moreover, the quality of spirometry needs to be improved.

  8. A clinical study of COPD severity assessment by primary care physicians and their patients compared with spirometry.

    Science.gov (United States)

    Mapel, Douglas W; Dalal, Anand A; Johnson, Phaedra; Becker, Laura; Hunter, Alyssa Goolsby

    2015-06-01

    Primary care physicians often do not use spirometry to confirm the diagnosis of chronic obstructive pulmonary disease. This project was designed to see how well physicians' impressions about their patients' chronic obstructive pulmonary disease severity correlate with the severity of airflow obstruction measured by spirometry and to assess whether spirometry results subsequently changed the physicians' opinions about chronic obstructive pulmonary disease severity and treatment. We performed a multicenter, cross-sectional, observational study conducted in 83 primary care clinics from across the United States. A total of 899 patients with a clinical diagnosis of chronic obstructive pulmonary disease completed a questionnaire and spirometry testing. Physicians completed a questionnaire and case report forms. Concordance among physician ratings, patient ratings, and spirometry results was evaluated. Physicians' chronic obstructive pulmonary disease severity ratings before spirometry were accurate for only 30% of patients with evaluable spirometry results, and disease severity in 41% of patients was underestimated. Physicians also underestimated severity compared with patients' self-assessment among 42% of those with evaluable results. After spirometry, physicians changed their opinions on the severity for 30% of patients and recommended treatment changes for 37%. Only 75% of patients performed at least 1 high-quality spirometry test; however, the physicians' opinions and treatment decisions were similar regardless of suboptimal test results. Without performing spirometry, physicians are likely to underestimate their patients' chronic obstructive pulmonary disease severity or inadequately characterize their patients' lung disease. Spirometry changed the physicians' clinical impressions and treatments for approximately one third of these patients; thus, spirometry is a valuable tool for chronic obstructive pulmonary disease management in primary care. Copyright © 2015

  9. Choosing wisely: adherence by physicians to recommended use of spirometry in the diagnosis and management of adult asthma.

    Science.gov (United States)

    Sokol, Kristin C; Sharma, Gulshan; Lin, Yu-Li; Goldblum, Randall M

    2015-05-01

    The National Asthma Education and Prevention Program (NAEPP) and the American Thoracic Society provide guidelines stating that physicians should use spirometry in the diagnosis and management of asthma. The aim of this study was to evaluate the trends, over a 10-year period, in the utilization of spirometry in patients newly diagnosed with asthma. We hypothesized that spirometry use would increase in physicians who care for asthma patients, especially since 2007, when the revised NAEPP guidelines were published. This retrospective cohort analysis of spirometry use in subjects newly diagnosed with asthma used a privately insured adult population for the years 2002-2011. Our primary outcome of interest was spirometry performed within a year (± 365 days) of the initial date of asthma diagnosis. We also examined the type of asthma medications prescribed. In all, 134,208 patients were found to have a diagnosis of asthma. Only 47.6% had spirometry performed within 1 year of diagnosis. Younger patients, males, and those residing in the Northeast were more likely to receive spirometry. Spirometry use began to decline in 2007. Patients cared for by specialists were more likely to receive spirometry than those cared for by primary care physicians; 80.1% vs 23.3%, respectively. Lastly, even without spirometry, a significant portion of patients (78.3%) was prescribed asthma drugs. Our study suggests that spirometry is underutilized in newly diagnosed asthma patients. Moreover, the use of controller medications in those diagnosed with asthma without spirometry remains high. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Age- and size-related reference ranges: a case study of spirometry through childhood and adulthood.

    Science.gov (United States)

    Cole, T J; Stanojevic, S; Stocks, J; Coates, A L; Hankinson, J L; Wade, A M

    2009-02-28

    Age-related reference ranges are useful for assessing growth in children. The LMS method is a popular technique for constructing growth charts that model the age-changing distribution of the measurement in terms of the median, coefficient of variation and skewness. Here the methodology is extended to references that depend on body size as well as age, by exploiting the flexibility of the generalised additive models for location, scale and shape (GAMLSS) technique. GAMLSS offers general linear predictors for each moment parameter and a choice of error distributions, which can handle kurtosis as well as skewness. A key question with such references is the nature of the age-size adjustment, additive or multiplicative, which is explored by comparing the identity link and log link for the median predictor.There are several measurements whose reference ranges depend on both body size and age. As an example, models are developed here for the first four moments of the lung function variables forced expiratory volume in 1 s (FEV(1)), forced vital capacity (FVC) and FEV(1)/FVC in terms of height and age, in a data set of 3598 children and adults aged 4 to 80 years. The results show a strong multiplicative association between spirometry, height and age, with a large and nonlinear age effect across the age range. Variability also depends nonlinearly on age and to a lesser extent on height. FEV(1) and FVC are close to normally distributed, while FEV(1)/FVC is appreciably skew to the left. GAMLSS is a powerful technique for the construction of such references, which should be useful in clinical medicine. Copyright (c) 2008 John Wiley & Sons, Ltd.

  11. The effect of medical clowns on performance of spirometry among preschool aged children.

    Science.gov (United States)

    Nir, Vered; Schichter-Konfino, Vered; Kassem, Eias; Klein, Adi

    2018-04-02

    Medical clowns (MCs) are known to assist in reducing pain and alleviating anxiety. The objective of this study is to evaluate the ability of MCs to assist preschoolers in performing spirometry. A prospective, randomized controlled trial. Children aged 3-6 years participated. After a first spirometry, children were divided into two groups: the first performed a second spirometry with an MC. The second repeated spirometry with the technician. Primary outcome was second spirometry values compared between the groups. Secondary outcome were change in spirometry values within groups, and difference between the groups. A total of 140 children participated. The groups did not differ in age, sex, mother tongue, or weight. Nor in mean FVC (MC 89.2% ± 16.7, control 89.5% ± 16.3) mean FEV1 (MC 91.3% ± 15.6, control 94.2% ± 16.8), and expiratory time (MC 1.58 ± 0.43, control 1.7 ± 0.44) in first spirometry. In second spirometry the control group had a similar FVC, FEV1, and expiratory time. The MC group had a significant improvement in all parameters: FVC: MC 95.3% ± 15.5, control 89.3% ± 19.1, FEV1: MC 98.0% ± 15.6, control 91.8% ± 19.3, and expiratory time MC 1.96 ± 0.55, control 1.84 ± 0.52. The differences between the groups between first and second attempt were significant (P-value FVC 0.000, FEV1 0.000, expiratory time 0.003). MCs improved performance of spirometry among preschoolers. It is possible that laughter and relief of stress had a physiological effect. Further studies are required to better establish the ability of MCs to improve active participation and to better understand whether the mechanism of the improvement is better cooperation or true physiological change. © 2018 Wiley Periodicals, Inc.

  12. Spirometry in Asthma Care: A Review of the Trends and Challenges in Pediatric Practice

    Science.gov (United States)

    Ayuk, Adaeze C; Uwaezuoke, Samuel N; Ndukwu, Chizalu I; Ndu, Ikenna K; Iloh, Kenechukwu K; Okoli, Chinyere V

    2017-01-01

    Background: Given the rising incidence of noncommunicable diseases (NCDs) globally, especially bronchial asthma, there is the need to reduce the associated morbidity and mortality by adopting an objective means of diagnosis and monitoring. Aim: This article aims to review the trends and challenges in the use of spirometry for managing childhood bronchial asthma especially in developing countries. Methods: We conducted a literature search of published data on the use of spirometry for the diagnosis of childhood bronchial asthma with special emphasis resource-poor countries. Results: Guidelines for the diagnosis and treatment of childhood asthma recommend the use of spirometry, but this is currently underused in both tertiary and primary care settings especially in developing countries. Lack of spirometers and proper training in their use and interpretation of findings as well as a dearth of asthma guidelines remains core to the underuse of spirometry in managing children with asthma. Targeting education of health care staff was, however, observed to improve its utility, and practical implementable strategies are highlighted. Conclusions: Spirometry is not frequently used for asthma diagnosis in pediatric practice especially in resource-poor countries where the NCD burden is higher. Strategies to overcome the obstacles are implementable and can make a difference in reducing the burden of NCD. PMID:28781518

  13. Accuracy of spirometry for detection of asthma: a cross-sectional study.

    Science.gov (United States)

    Meneghini, Andréa Cristina; Paulino, Ana Carolina Botto; Pereira, Luciano Penha; Vianna, Elcio Oliveira

    2017-01-01

    Asthma is a chronic inflammatory disease with airway hyperresponsiveness. Spirometry is the most commonly used test among asthmatic patients. Another functional test used for diagnosing asthma is the bronchial challenge test. The aim of this study was to analyze the accuracy of spirometry for detecting asthma in the general population. Cross-sectional study with data analysis to evaluate the accuracy of spirometry through calculating sensitivity, specificity and predictive values and through the kappa agreement test. Subjects who constituted a birth cohort were enrolled at the age of 23 to 25 years. Spirometric abnormality was defined as reduced forced expiratory volume in one second, i.e. lower than 80% of the predicted value. Measurement of bronchial responsiveness was performed by means of the bronchial challenge test with methacholine. The gold-standard diagnosis of asthma was defined as the presence of bronchial hyperresponsiveness in association with respiratory symptoms. Asthma was detected in 200 subjects (10.4%) out of the sample of 1922 individuals. Spirometric abnormality was detected in 208 subjects (10.9%) of the sample. The specificity of spirometric abnormality for detecting asthma was 90%, sensitivity was 23%, positive predictive value was 22%, and negative predictive value was 91%. The kappa test revealed weak agreement of 0.13 (95% confidence interval, CI: 0.07-0.19) between spirometry and the diagnosis of asthma. Spirometry, as a single test, has limitations for detecting asthma in the general population.

  14. The majority of participants with abnormal spirometry at walk-in consult their general practitioner as recommended.

    Science.gov (United States)

    Kølner-Augustson, Line; Thøgersen, Niels; Faaborg, Thea Heide; Weinreich, Ulla Møller

    2015-11-01

    A number of studies inviting citizens to perform spirometry without need for a previous appointment have been performed to determine the need for general screening of the population for chronic obstructive pulmonary disease (COPD). Yet, no studies have examined how many of the participants follow the advice given to consult their general practitioner (GP) afterwards. A walk-in spirometry was carried out on the island of Laesoe. All habitants above the age of 18 years were invited. In total, 142 were eligible for the study. Participants with an abnormal spirometry were recommended to consult their GP immediately, whereas smokers with symptoms, but with a normal spirometry, were recommended to consult their GP within a year for another spirometry. A follow-up was performed to investigate whether the participants had followed this advice. In total, 52% (74/142) of the participants were advised to contact their GP: 34 due to an abnormal spirometry and 40 due to smoking and respiratory symptoms. Among the participants with an abnormal spirometry, 79% saw their GP within three months, whereas 30% of the current smokers saw their GP within 9-15 months. Lung disease was diagnosed in 56% (19/34) of the participants who initially had an abnormal spirometry. Among the participants who had an abnormal spirometry at screening, 79% consulted their GP as recommended. Furthermore, 52% of the participants who had an abnormal spirometry were subsequently diagnosed with pulmonary disease by their GP. We conclude that walk-in spirometry is a useful tool for early diagnosis of COPD. none. not relevant.

  15. The impact of spirometry in the Ebeltoft Health Promotion Study (EHPS)

    DEFF Research Database (Denmark)

    Ørts, Lene Maria; Ottesen, Anders Løkke; Bjerregaard, Anne-Louise

    Background: It has been stressed that early detection of impaired lung function can be useful in prevention of lung diseases. It is unknown whether spirometry as an integrated part of preventive health checks including a questionnaire regarding risk factors and exposure, can be used for early...... detection of lung diseases.The aim of the study is to describe exposure characteristics and spirometry parameters 15 years ahead of a diagnosis of Chronic Obstructive Pulmonary Disease (COPD*)*Defined by FEV1/FVC ... (n=573), aged 30-49 years at baseline, attended in 1991 and 2006 a health check and a follow-up consultation at their own general practitioner. The characteristics of the citizens are described according to sex, age, smoking history, exposure, lung symptoms and spirometry values. Register information...

  16. The value of including spirometry in health checks - a randomized controlled study in primary health care

    DEFF Research Database (Denmark)

    Ørts, Lene Maria; Ottesen, Anders Løkke; Bjerregaard, Anne-Louise

    Background Lung diseases are among the most frequent and most serious ailments in Denmark. Preventive health checks including spirometry can be used to detect lung diseases earlier. Over time the attendance at preventive health checks has decreased and at present the response rate is approximately...... 50%. Little is known about initiatives that can influence the attendance rate. Objectives To examine whether focused information on spirometry in the invitation material will influence the attendance in preventive health checks. Materiel/Methods Design: A randomized controlled study on information...... on spirometry embedded in “Check your health Prevention Program, CHPP” from 2015-16. CHPP is a house-hold cluster randomized controlled trial offering a preventive health check to 30-49 year olds in a Danish municipality during the years 2012 through to 2017 (n= 26,216), carried out in collaboration between...

  17. Excessive Daytime Sleepiness

    Directory of Open Access Journals (Sweden)

    Yavuz Selvi

    2016-06-01

    Full Text Available Excessive daytime sleepiness is one of the most common sleep-related patient symptoms, with preva-lence in the community estimated to be as high as 18%. Patients with excessive daytime sleepiness may exhibit life threatening road and work accidents, social maladjustment, decreased academic and occupational performance and have poorer health than comparable adults. Thus, excessive daytime sleepiness is a serious condition that requires investigation, diagnosis and treatment primarily. As with most medical condition, evaluation of excessive daytime sleepiness begins a precise history and various objective and subjective tools have been also developed to assess excessive daytime sleepiness. The most common causes of excessive daytime sleepiness are insufficient sleep hygiene, chronic sleep deprivation, medical and psychiatric conditions and sleep disorders, such as obstructive sleep apnea, medications, and narcolepsy. Treatment option should address underlying contributors and promote sleep quantity by ensuring good sleep hygiene. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2016; 8(2: 114-132

  18. Is preoperative spirometry a predictive marker for postoperative complications after colorectal cancer surgery?

    Science.gov (United States)

    Tajima, Yuki; Tsuruta, Masashi; Yahagi, Masashi; Hasegawa, Hirotoshi; Okabayashi, Koji; Shigeta, Kohei; Ishida, Takashi; Kitagawa, Yuko

    2017-09-01

    Spirometry is a basic test that provides much information about pulmonary function; it is performed preoperatively in almost all patients undergoing colorectal cancer (CRC) surgery in our hospital. However, the value of spirometry as a preoperative test for CRC surgery remains unknown. The aim of this study was to determine whether spirometry is useful to predict postoperative complications (PCs) after CRC surgery. The medical records of 1236 patients who had preoperative spirometry tests and underwent CRC surgery between 2005 and 2014 were reviewed. Preoperative spirometry results, such as forced vital capacity (FVC), one-second forced expiratory volume (FEV1), %VC (FVC/predicted VC) and FEV1/FVC (%FEV1), were analyzed with regard to PCs, including pneumonia. PCs were found in 383 (30.9%) patients, including 218 (56%) with surgical site infections, 67 (17%) with bowel obstruction, 62 (16%) with leakage and 20 (5.2%) with pneumonia. Of the spirometry results, %VC was correlated with PC according to logistic regression analysis (odds ratio, OR = 0.99, 95% confidence interval, CI = 0.98-0.99; P = 0.034). Multivariate analysis after adjusting for male sex, age, laparoscopic surgery, tumor location, operation time and blood loss showed that a lower %VC tends to be a risk factor for PC (OR = 0.99, 95% CI = 0.98-1.002; P = 0.159) and %VC was an independent risk factor for postoperative pneumonia in PCs (OR = 0.97, 95% CI = 0.94-0.99; P = 0.049). In CRC surgery, %VC may be a predictor of postoperative complications, especially pneumonia. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. Evaluation of the Global Lung Initiative 2012 Reference Values for Spirometry in African Children.

    Science.gov (United States)

    Arigliani, Michele; Canciani, Mario C; Mottini, Giovanni; Altomare, Michele; Magnolato, Andrea; Loa Clemente, Sofia Vanda; Tshilolo, Leon; Cogo, Paola; Quanjer, Philip H

    2017-01-15

    Despite the high burden of respiratory disease, no spirometry reference values for African children are available. Investigate whether the Global Lung Initiative (GLI-2012) reference values for spirometry are appropriate for children in sub-Saharan Africa and assess the impact of malnutrition on lung function. Anthropometry and spirometry were obtained in children aged 6 to 12 years from urban and semiurban schools in three African countries. Spirometry z-scores were derived using the GLI-2012 prediction equations for African Americans. Thinness (body mass index z-score Spirometry outcomes were compared with those of African American children from the third National Health and Nutrition Survey. Spirometry data were analyzed from 1,082 schoolchildren (51% boys) aged 6.0 to 12.8 years in Angola (n = 306), Democratic Republic of the Congo (n = 377), and Madagascar (n = 399). GLI-2012 provided a good fit with mean (SD) z-scores of -0.11 (0.83) for FEV 1 , -0.08 (0.86) for FVC, and -0.07 (0.83) for FEV 1 /FVC. Because of low scatter, the fifth centile corresponded to -1.3 z-scores in boys and -1.5 z-scores in girls. Malnourished African children had a normal FEV 1 /FVC ratio but significant reductions of ∼0.5 z-scores (∼5%) in FEV 1 and FVC compared with African American peers from the third National Health and Nutrition Survey. Children in Angola had the lowest, and those in Madagascar had the highest, zFEV 1 and zFVC. The results of this study support the use of GLI-2012 reference values for schoolchildren in sub-Saharan Africa. Malnutrition affects body growth, leading to a proportionately smaller FEV 1 and FVC without respiratory impairment, as shown by the normal FEV 1 /FVC ratio.

  20. Daily Home Spirometry: An Effective Tool for Detecting Progression in Idiopathic Pulmonary Fibrosis.

    Science.gov (United States)

    Russell, Anne-Marie; Adamali, Huzaifa; Molyneaux, Philip L; Lukey, Pauline T; Marshall, Richard P; Renzoni, Elisabetta A; Wells, Athol U; Maher, Toby M

    2016-10-15

    Recent clinical trial successes have created an urgent need for earlier and more sensitive endpoints of disease progression in idiopathic pulmonary fibrosis (IPF). Domiciliary spirometry permits more frequent measurement of FVC than does hospital-based assessment, which therefore affords the opportunity for a more granular insight into changes in IPF progression. To determine the feasibility and reliability of measuring daily FVC in individuals with IPF. Subjects with IPF were given handheld spirometers and instruction on how to self-administer spirometry. Subjects recorded daily FEV 1 and FVC for up to 490 days. Clinical assessment and hospital-based spirometry was undertaken at 6 and 12 months, and outcome data were collected for 3 years. Daily spirometry was recorded by 50 subjects for a median period of 279 days (range, 13-490 d). There were 18 deaths during the active study period. Home spirometry showed excellent correlation with hospital-obtained readings. The rate of decline in FVC was highly predictive of outcome and subsequent mortality when measured at 3 months (hazard ratio [HR], 1.040; 95% confidence interval [CI], 1.021-1.062; P ≤ 0.001), 6 months (HR, 1.024; 95% CI, 1.014-1.033; P spirometry in patients with IPF is highly clinically informative and is feasible to perform for most of these patients. The relationship between mortality and rate of change of FVC at 3 months suggests that daily FVC may be of value as a primary endpoint in short proof-of-concept IPF studies.

  1. Methacholine bronchial provocation measured by spirometry versus wheeze detection in preschool children

    Directory of Open Access Journals (Sweden)

    Yahav Yaacov

    2005-06-01

    Full Text Available Abstract Background Determination of PC20-FEV1 during Methacholine bronchial provocation test (MCT is considered to be impossible in preschool children, as it requires repetitive spirometry sets. The aim of this study was to assess the feasibility of determining PC20-FEV1 in preschool age children and compares the results to the wheeze detection (PCW method. Methods 55 preschool children (ages 2.8–6.4 years with recurrent respiratory symptoms were recruited. Baseline spirometry and MCT were performed according to ATS/ERS guidelines and the following parameters were determined at baseline and after each inhalation: spirometry-indices, lung auscultation at tidal breathing, oxygen saturation, respiratory and heart rate. Comparison between PCW and PC20-FEV1 and clinical parameters at these end-points was done by paired Student's t-tests. Results and discussion Thirty-six of 55 children (65.4% successfully performed spirometry-sets up to the point of PCW. PC20-FEV1 occurred at a mean concentration of 1.70+/-2.01 while PCW occurred at a mean concentration of 4.37+/-3.40 mg/ml (p 1 by 44.7+/-14.5%; PEFR by 40.5+/-14.5 and FEF25–75 by 54.7+/-14.4% (P Conclusion Determination of PC20-FEV1 by spirometry is feasible in many preschool children. PC20-FEV1 often appears at lower provocation dose than PCW. The lower dose may shorten the test and encourage participation. Significant decrease in spirometry indices at PCW suggests that PC20-FEV1 determination may be safer.

  2. Spirometry and Impulse Oscillometry in Preschool Children: Acceptability and Relationship to Maternal Smoking in Pregnancy.

    Science.gov (United States)

    Kattan, Meyer; Bacharier, Leonard B; O'Connor, George T; Cohen, Robyn; Sorkness, Ronald L; Morgan, Wayne; Gergen, Peter J; Jaffee, Katy F; Visness, Cynthia M; Wood, Robert A; Bloomberg, Gordon R; Doyle, Susan; Burton, Ryan; Gern, James E

    2018-02-13

    Comparisons of the technical acceptability of spirometry and impulse oscillometry (IOS) and clinical correlations of the measurements have not been well studied in young children. There are no large studies focused on African American and Hispanic children. We sought to (1) compare the acceptability of spirometry and IOS in 3- to 5-year-old children and (2) examine the relationship of maternal smoking during pregnancy to later lung function. Spirometry and IOS were attempted at 4 sites from the Urban Environmental and Childhood Asthma Study birth cohort at ages 3, 4, and 5 years (472, 471, and 479 children, respectively). We measured forced expiratory flow in 0.5 s (forced expiratory volume in 0.5 seconds [FEV 0.5 ]) with spirometry and area of reactance (A X ), resistance and reactance at 5 Hz (R 5 and X 5 , respectively) using IOS. Children were more likely to achieve acceptable maneuvers with spirometry than with IOS at age 3 (60% vs 46%, P < .001) and 5 years (89% vs 84%, P = .02). Performance was consistent among the 4 study sites. In children without recurrent wheeze, there were strong trends for higher FEV 0.5 and lower R 5 and A X over time. Maternal smoking during pregnancy was associated with higher A X at ages 4 and 5 years (P < .01 for both years). There was no significant difference in FEV 0.5 between children with and without in utero exposure to smoking. There is a higher rate of acceptable maneuvers with spirometry compared with IOS, but IOS may be a better indicator of peripheral airway function in preschool children. Copyright © 2018 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  3. Active case finding strategy for chronic obstructive pulmonary disease with handheld spirometry.

    Science.gov (United States)

    Kim, Joo Kyung; Lee, Chang Min; Park, Ji Young; Kim, Joo Hee; Park, Sung-Hoon; Jang, Seung Hun; Jung, Ki-Suck; Yoo, Kwang Ha; Park, Yong Bum; Rhee, Chin Kook; Kim, Deog Kyeom; Hwang, Yong Il

    2016-12-01

    The early detection and diagnosis of chronic obstructive pulmonary disease (COPD) is critical to providing appropriate and timely treatment. We explored a new active case-finding strategy for COPD using handheld spirometry.We recruited subjects over 40 years of age with a smoking history of more than 10 pack-years who visited a primary clinic complaining of respiratory symptoms. A total of 190 of subjects were enrolled. Medical information was obtained from historical records and physical examination by general practitioners. All subjects had their pulmonary function evaluated using handheld spirometry with a COPD-6 device. Because forced expiratory volume in 6 seconds (FEV6) has been suggested as an alternative to FVC, we measured forced expiratory volume in 1 second (FEV1)/FEV6 for diagnosis of airflow limitation. All subjects were then referred to tertiary referral hospitals to complete a "Could it be COPD?" questionnaire, handheld spiromtery, and conventional spirometry. The results of each instrument were compared to evaluate the efficacy of both handheld spirometry and the questionnaire.COPD was newly diagnosed in 45 (23.7%) patients. According to our receiver-operating characteristic (ROC) curve analysis, sensitivity and specificity were maximal when the FEV1/FEV6 ratio was less than 77%. The area under the ROC curve was 0.759. The sensitivity, specificity, positive predictive value, and negative predictive value were 72.7%, 77.1%, 50%, and 90%, respectively. The area under the ROC curve of respiratory symptoms listed on the questionnaire ranged from 0.5 to 0.65, which indicates that there is almost no difference compared with the results of handheld spirometry.The present study demonstrated the efficacy of handheld spirometry as an active case-finding tool for COPD in a primary clinical setting. This study suggested that physicians should recommend handheld spirometry for people over the age of 40, who have a smoking history of more than 10 pack

  4. Asthma, chronic obstructive pulmonary disease, or both? Diagnostic labeling and spirometry in primary care patients aged 40 years or more

    Science.gov (United States)

    Melbye, Hasse; Drivenes, Elin; Dalbak, Lene G; Leinan, Tone; Høegh-Henrichsen, Svein; Østrem, Anders

    2011-01-01

    Aims To describe symptoms and lung function in patients registered with asthma or chronic obstructive pulmonary disease (COPD) in primary care and to examine how spirometry findings fit with general practitioners’ (GPs) diagnoses. Methods Patients aged ≥40 years with a diagnosis of asthma or COPD registered in the electronic medical record during the previous 5 years were recruited at seven GP offices in Norway in 2009–2010. Registered diagnosis, spirometry results, comorbidity, and reported symptoms were compared. Results Among 376 patients, 62% were women. Based on Global Initiative for Chronic Obstructive Lung Diseases criteria, a spirometry diagnosis of COPD could be made in 68.1% of the patients with a previous COPD diagnosis and in 17.1% of those diagnosed with asthma only (P spirometry was 0.50. A restrictive spirometry pattern was found in 19.4% and more frequently in patients diagnosed with both asthma and COPD (23.9%) than in patients diagnosed with COPD only (6.8%, P = 0.003). Conclusion The ability of GPs to differentiate between asthma and COPD seems to have considerably improved during the last decade, probably due to the dissemination of spirometry and guidelines for COPD diagnosis. A diagnosis of COPD that cannot be confirmed by spirometry represents a challenge in clinical practice, in particular when a restrictive pattern on spirometry is found. PMID:22135492

  5. Differences in the use of spirometry between rural and urban primary care centers in Spain

    Directory of Open Access Journals (Sweden)

    Márquez-Martín E

    2015-08-01

    Full Text Available Eduardo Márquez-Martín,1 Joan B Soriano,2 Myriam Calle Rubio,3 Jose Luis Lopez-Campos1,4 On behalf of the 3E project 1Unidad Médico-Quirúrgica de Enfermedades Respiratorias, Instituto de Biomedicina de Sevilla (IBiS, Hospital Universitario Virgen del Rocío, Universidad de Sevilla, Sevilla, 2Instituto de Investigación Hospital Universitario de la Princesa (IISP, Universidad Autónoma de Madrid, Cátedra UAM-Linde, 3Servicio de Neumología, Hospital Universitario Clínico San Carlos, 4Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (CIBERES, Instituto de Salud Carlos III, Madrid, Spain Objectives: The aim of this study is to evaluate the ability and practice of spirometry, training of technicians, and spirometry features in primary care centers in Spain, evaluating those located in a rural environment against those in urban areas.Methods: An observational cross-sectional study was conducted in 2012 by a telephone survey in 970 primary health care centers in Spain. The centers were divided into rural or urban depending on the catchment population. The survey contacted technicians in charge of spirometry and consisted of 36 questions related to the test that included the following topics: center resources, training doctors and technicians, using the spirometer, bronchodilator test, and the availability of spirometry and maintenance.Results: Although the sample size was achieved in both settings, rural centers (RCs gave a lower response rate than urban centers (UCs. The number of centers without spirometry in rural areas doubled those in the urban areas. Most centers had between one and two spirometers. However, the number of spirometry tests per week was significantly lower in RCs than in UCs (4 [4.1%] vs 6.9 [5.7%], P<0.01. The availability of a specific schedule for conducting spirometries was higher in RCs than in UCs (209 [73.0%] vs 207 [64.2%], P=0.003. RCs were more satisfied with the spirometries (7.8 vs 7.6, P

  6. Acute effects of volume-oriented incentive spirometry on chest wall volumes in patients after a stroke.

    Science.gov (United States)

    Lima, Illia Ndf; Fregonezi, Guilherme Af; Melo, Rodrigo; Cabral, Elis Ea; Aliverti, Andrea; Campos, Tânia F; Ferreira, Gardênia Mh

    2014-07-01

    The aim of the present study was to assess how volume-oriented incentive spirometry applied to patients after a stroke modifies the total and compartmental chest wall volume variations, including both the right and left hemithoraces, compared with controls. Twenty poststroke patients and 20 age-matched healthy subjects were studied by optoelectronic plethysmography during spontaneous quiet breathing (QB), during incentive spirometry, and during the recovery period after incentive spirometry. Incentive spirometry was associated with an increased chest wall volume measured at the pulmonary rib cage, abdominal rib cage and abdominal compartment (P = .001) and under 3 conditions (P spirometry, and postincentive spirometry, respectively. Under all 3 conditions, the contribution of the abdominal compartment to VT was greater in the stroke subjects (54.1, 43.2, and 48.9%) than in the control subjects (43.7, 40.8, and 46.1%, P = .039). In the vast majority of subjects (13/20 and 18/20 during QB and incentive spirometry, respectively), abdominal expansion precedes rib cage expansion during inspiration. Greater asymmetry between the right and left hemithoracic expansions occurred in stroke subjects compared with control subjects, but it decreased during QB (62.5%, P = .002), during incentive spirometry (19.7%), and postincentive spirometry (67.6%, P = .14). Incentive spirometry promotes increased expansion in all compartments of the chest wall and reduces asymmetric expansion between the right and left parts of the pulmonary rib cage; therefore, it should be considered as a tool for rehabilitation. Copyright © 2014 by Daedalus Enterprises.

  7. Semiautomatic assessment of respiratory motion in dynamic MRI. Comparison with simultaneously acquired spirometry

    Energy Technology Data Exchange (ETDEWEB)

    Tetzlaff, R.; Eichinger, M.; Puderbach, M. [Radiologie, Deutsches Krebsforschungszentrum, Heidelberg (Germany); Schoebinger, M.; Meinzer, H.P. [Medizinische und Biologische Informatik, Deutsches Krebsforschungszentrum, Heidelberg (Germany); Kauczor, H.U. [Diagnostische Radiologie, Radiologische Universitaetsklinik, Heidelberg (Germany)

    2008-11-15

    Purpose: supplementing global spirometry with regional information could allow for earlier and more specific diagnosis of lung disease. Dynamic magnetic resonance imaging (dMRI) makes it possible to derive functional parameters from the visualization of the pulmonary motion of single lungs. The aim of this study was to compare high temporal resolution measurements of left and right thoracic diameters to simultaneously acquired spirometry. Materials and methods: 10 healthy volunteers underwent 2-dimensional dMRI of both lungs at 1.5 T. Spirometry was performed simultaneously with an MRI-compatible spirometer. Thoracic diameters were measured semiautomatically and compared to simultaneously measured spirometric volumes. A dMRI surrogate for the Tiffeneau Index was compared to the spirometric Tiffeneau. Results: The volume-time and flow-volume curves from dMRI were very similar to the spirometric curves. The semiautomatically measured diameters correlated well with the spirometric volumes (r > = 0.8, p < 10-15). Agreement between the methods at full temporal resolution was not as convincing (width of 95% limits of agreement interval up to 56%). Good agreement was found between the Tiffenau surrogate and spirometry (width of 95% limits of agreement interval of 14.5%). (orig.)

  8. The Vital Capacity Is Vital: Epidemiology and Clinical Significance of the Restrictive Spirometry Pattern.

    Science.gov (United States)

    Godfrey, Mark S; Jankowich, Matthew D

    2016-01-01

    Epidemiologic research has revealed a substantial portion of the general population with abnormal spirometry results that are characterized by decreased FEV1 and FVC but a preserved FEV1/FVC ratio. This restrictive spirometry pattern (RSP) is inconsistently defined in the literature and not well addressed by current guidelines; there is an accumulating body of evidence, however, that RSP is prevalent to a similar degree as airflow obstruction. Genetic and other risk factors for RSP, such as inhalational injuries and early life exposures, continue to be actively described. Although it seems that RSP is closely associated with the metabolic syndrome, diabetes, and systemic inflammation, it is not a simple marker of obesity. RSP is associated with adverse cardiovascular outcomes, as well as mortality, and it may be an underappreciated cause of functional impairments and respiratory symptoms. Improvement in outcomes in this population will require that clinicians have an appreciation for the significance of this spirometry pattern; additional research into the clinical and radiologic phenotype of these subjects is also needed. This article provides an overview of the recent developments in our understanding of this prevalent and highly morbid spirometry pattern. Published by Elsevier Inc.

  9. General practitioners' needs for ongoing support for the interpretation of spirometry tests.

    NARCIS (Netherlands)

    Poels, P.J.P.; Schermer, T.R.J.; Akkermans, R.P.; Jacobs, A.; Bogart-Jansen, M.; Bottema, B.J.A.M.; Weel, C. van

    2007-01-01

    BACKGROUND: Although one out of three general practitioners (GPs) carries out spirometry, the diagnostic interpretation of spirometric test results appears to be a common barrier for GPs towards its routine application. METHODS: Multivariate cross-sectional analysis of a questionnaire survey among

  10. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis

    NARCIS (Netherlands)

    de Vries, R.; Brinkman, P.; van der Schee, M. P.; Fens, N.; Dijkers, E.; Bootsma, S. K.; de Jongh, F. H. C.; Sterk, P. J.

    2015-01-01

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We

  11. Should the diagnosis of COPD be based on a single spirometry test?

    NARCIS (Netherlands)

    Schermer, T.R.; Robberts, B.; Crockett, A.J.; Thoonen, B.P.; Lucas, A.; Grootens, J.; Smeele, I.J.; Thamrin, C.; Reddel, H.K.

    2016-01-01

    Clinical guidelines indicate that a chronic obstructive pulmonary disease (COPD) diagnosis is made from a single spirometry test. However, long-term stability of diagnosis based on forced expiratory volume in 1 s over forced vital capacity (FEV1/FVC) ratio has not been reported. In primary care

  12. Spirometry utilization among Danish adults initiating medication targeting obstructive lung disease

    DEFF Research Database (Denmark)

    Koefoed, Mette

    2013-01-01

    litteraturen, at mange af disse patienter får medicinsk behandling for deres symptomer uden yderligere undersøgelser, selvom symptomer og klinisk undersøgelse ikke med tilstrækkelig sikkerhed kan prædiktere, hvem der har astma og eller KOL. Spirometri er anbefalet som Gold Standard for at bekræfte eller...... den diagnostiske proces og at blive udsat for unødig medicinsk behandling. Litteraturen tyder på, at mange medicinbrugere ikke bliver undersøgt med spirometri og muligvis ikke har obstruktive lungelidelser. Dette kvalitetsproblem bør afdækkes, og associationer med manglende spirometri i denne gruppe...... bør klarlægges, så interventioner kan målrettes. Formål: Blandt nye brugere af obstruktiv lungemedicin var formålet at: • Afdække i hvor høj grad spirometri var udført indenfor det første år, efter at medicineringen var påbegyndt • Afdække om patientkarakteristika såsom socioøkonomisk og demografisk...

  13. Semiautomatic assessment of respiratory motion in dynamic MRI. Comparison with simultaneously acquired spirometry

    International Nuclear Information System (INIS)

    Tetzlaff, R.; Eichinger, M.; Puderbach, M.; Schoebinger, M.; Meinzer, H.P.; Kauczor, H.U.

    2008-01-01

    Purpose: supplementing global spirometry with regional information could allow for earlier and more specific diagnosis of lung disease. Dynamic magnetic resonance imaging (dMRI) makes it possible to derive functional parameters from the visualization of the pulmonary motion of single lungs. The aim of this study was to compare high temporal resolution measurements of left and right thoracic diameters to simultaneously acquired spirometry. Materials and methods: 10 healthy volunteers underwent 2-dimensional dMRI of both lungs at 1.5 T. Spirometry was performed simultaneously with an MRI-compatible spirometer. Thoracic diameters were measured semiautomatically and compared to simultaneously measured spirometric volumes. A dMRI surrogate for the Tiffeneau Index was compared to the spirometric Tiffeneau. Results: The volume-time and flow-volume curves from dMRI were very similar to the spirometric curves. The semiautomatically measured diameters correlated well with the spirometric volumes (r > = 0.8, p < 10-15). Agreement between the methods at full temporal resolution was not as convincing (width of 95% limits of agreement interval up to 56%). Good agreement was found between the Tiffenau surrogate and spirometry (width of 95% limits of agreement interval of 14.5%). (orig.)

  14. A new spirometry-based algorithm to predict occupational pulmonary restrictive impairment.

    Science.gov (United States)

    De Matteis, S; Iridoy-Zulet, A A; Aaron, S; Swann, A; Cullinan, P

    2016-01-01

    Spirometry is often included in workplace-based respiratory surveillance programmes but its performance in the identification of restrictive lung disease is poor, especially when the prevalence of this condition is low in the tested population. To improve the specificity (Sp) and positive predictive value (PPV) of current spirometry-based algorithms in the diagnosis of restrictive pulmonary impairment in the workplace and to reduce the proportion of false positives findings and, as a result, unnecessary referrals for lung volume measurements. We re-analysed two studies of hospital patients, respectively used to derive and validate a recommended spirometry-based algorithm [forced vital capacity (FVC) 55%] for the recognition of restrictive pulmonary impairment. We used true lung restrictive cases as a reference standard in 2×2 contingency tables to estimate sensitivity (Sn), Sp and PPV and negative predictive values for each diagnostic cut-off. We simulated a working population aged spirometry-based algorithm may be adopted to accurately exclude pulmonary restriction and to possibly reduce unnecessary lung volume testing in an occupational health setting. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Is Home Spirometry Useful in Diagnosing Asthma in Children With Nonspecific Respiratory Symptoms?

    NARCIS (Netherlands)

    Brouwer, Alwin F. J.; Visser, Chantal A. N.; Duiverman, Eric J.; Roorda, Ruurd Jan; Brand, Paul L. P.

    Background: Variation of lung function is considered to be a hallmark of asthma. Although guidelines recommend measuring it as a diagnostic tool for asthma, the usefulness of this approach has not been studied in children. Aim: To assess the usefulness of home spirometry in children with nonspecific

  16. [Accesibility and use of spirometry in primary care centers in Catalonia].

    Science.gov (United States)

    Llauger, M Antònia; Rosas, Alba; Burgos, Felip; Torrente, Elena; Tresserras, Ricard; Escarrabill, Joan

    2014-01-01

    Examine the accessibility and use of forced spirometry (FS) in public primary care facilities centers in Catalonia. Cross-sectional study using a survey. Three hundred sixty-six Primary Care Teams (PCT) in Catalonia. Third quarter of 2010. Survey with information on spirometers, training, interpretation and quality control, and the priority that the quality of spirometry had for the team. Indicators FS/100 inhabitants/year, FS/month/PCT; FS/month/10,000 inhabitants. Response rate: 75%. 97.5% of PCT had spirometer and made an average of 2.01 spirometries/100 inhabitants (34.68 spirometry/PCT/month). 83% have trained professionals.>50% centers perform formal training but no information is available on the quality. 70% performed some sort of calibration. Interpretation was made by the family physician in 87.3% of cases. In 68% of cases not performed any quality control of exploration. 2/3 typed data manually into the computerized medical record.>50% recognized a high priority strategies for improving the quality. Despite the accessibility of EF efforts should be made to standardize training, increasing the number of scans test and promote systematic quality control. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  17. THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY

    Science.gov (United States)

    THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY. William F. McDonnell Human Studies Division, NHEERL, U.S. Environmental Protection Agency, RTP, NC 27711. Short-term exposure to ozone results in a neurally-mediated decrease in the ab...

  18. Respiratory symptoms necessitating spirometry among soldiers with Iraq/Afghanistan war lung injury.

    Science.gov (United States)

    Szema, Anthony M; Salihi, Walid; Savary, Khalil; Chen, John J

    2011-09-01

    New-onset asthma rates are higher among US soldiers deployed to Iraq/Afghanistan than stateside, but overall respiratory symptom and spirometry rates among soldiers returning from Iraq/Afghanistan have not yet been addressed. We determined these rates in soldiers deployed to Iraq/Afghanistan versus troops stationed elsewhere. Retrospective review of active-duty soldiers (2004 to 2010) registered at Veterans Affairs Medical Center, Northport, New York, with Long Island/New York City zip codes. Subjects were examined by physicians or physicians' assistants. We counted number of spirometries, which required respiratory symptoms, and the provider was required to submit a diagnosis as part of the request process. Twenty-five percent of 7151 troops went to Iraq/Afghanistan (n = 1816) and 75% went elsewhere (n = 5335), with more smokers in the Iraq/Afghanistan group (16.1% vs 3.3%). Rates of symptoms and spirometry were 14.5% and 1.8%, for Iraq/Afghanistan, versus troops deployed elsewhere, respectively (P Afghanistan war lung injury is common and rates of symptoms leading to a diagnosis requiring spirometry are high. (C)2011The American College of Occupational and Environmental Medicine

  19. A retrospective study of two populations to test a simple rule for spirometry.

    Science.gov (United States)

    Ohar, Jill A; Yawn, Barbara P; Ruppel, Gregg L; Donohue, James F

    2016-06-04

    Chronic lung disease is common and often under-diagnosed. To test a simple rule for conducting spirometry we reviewed spirograms from two populations, occupational medicine evaluations (OME) conducted by Saint Louis and Wake Forest Universities at 3 sites (n = 3260, mean age 64.14 years, 95 % CI 58.94-69.34, 97 % men) and conducted by Wake Forest University preop clinic (POC) at one site (n = 845, mean age 62.10 years, 95 % CI 50.46-73.74, 57 % men). This retrospective review of database information that the first author collected prospectively identified rates, types, sensitivity, specificity and positive and negative predictive value for lung function abnormalities and associated mortality rate found when conducting spirometry based on the 20/40 rule (≥20 years of smoking in those aged ≥ 40 years) in the OME population. To determine the reproducibility of the 20/40 rule for conducting spirometry, the rule was applied to the POC population. A lung function abnormality was found in 74 % of the OME population and 67 % of the POC population. Sensitivity of the rule was 85 % for an obstructive pattern and 77 % for any abnormality on spirometry. Positive and negative predictive values of the rule for a spirometric abnormality were 74 and 55 %, respectively. Patients with an obstructive pattern were at greater risk of coronary heart disease (odds ratio (OR) 1.39 [confidence interval (CI) 1.00-1.93] vs. normal) and death (hazard ratio (HR) 1.53, 95 % CI 1.20-1.84) than subjects with normal spirometry. Restricted spirometry patterns were also associated with greater risk of coronary disease (odds ratio (OR) 1.7 [CI 1.23-2.35]) and death (Hazard ratio 1.40, 95 % CI 1.08-1.72). Smokers (≥ 20 pack years) age ≥ 40 years are at an increased risk for lung function abnormalities and those abnormalities are associated with greater presence of coronary heart disease and increased all-cause mortality. Use of the 20/40 rule could provide a

  20. Impulse oscillometry in acute and stable asthmatic children: a comparison with spirometry.

    Science.gov (United States)

    Batmaz, Sehra Birgul; Kuyucu, Semanur; Arıkoglu, Tugba; Tezol, Ozlem; Aydogdu, Ayse

    2016-01-01

    Lung function tests have attracted interest for the diagnosis and follow-up of childhood asthma in recent years. For patients who cannot perform forced expiratory maneuvers, impulse oscillometry (IOS), performed during spontaneous breathing, may be an alternative tool. Thirty-five acute, 107 stable asthmatic and 103 healthy children who presented to our clinic performed IOS followed by spirometry before and after salbutamol inhalation. The mean baseline and reversibility of IOS and spirometry parameters were compared between the groups. Correlation analyses were undertaken within the asthmatics, and the healthy controls separately. To distinguish the three groups, the sensitivity and specificity of baseline and reversibility values of IOS and spirometry were computed. When spirometry was taken as the gold standard, the discriminating performance of IOS to detect the airway obstruction and reversibility was investigated. The mean absolute values of Zrs, R5, R5-R20, X5, X10, X15, Fres, AX, and all spirometric parameters, and the mean reversibility values of R5, R10, Fres, AX and forced expiratory volume in one second were different between the groups and the highest area under curve values to discriminate the groups was obtained from area of reactance (AX) and ΔAX. Zrs, all resistance (including R5-R20) and reactance parameters, Fres and AX were correlated with at least one spirometric parameter. Spirometric reversibility was detected by ≤-22.34 and ≤-39.05 cut-off values of ΔR5 and ΔAX, respectively. IOS has shown a highly significant association with spirometric indices and reversibility testing. It may be a substitute for spirometry in children who fail to perform forced expiratory maneuvers.

  1. Hyperhidrosis (Excessive Sweating)

    Science.gov (United States)

    ... who have this type are otherwise healthy. In medical terminology, the word “primary” means that the cause is not another medical condition. Secondary hyperhidrosis In medical terminology, “secondary” means that the excessive sweating (hyperhidrosis) has ...

  2. Spirometry training courses: Content, delivery and assessment - a position statement from the Australian and New Zealand Society of Respiratory Science.

    Science.gov (United States)

    Swanney, Maureen P; O'Dea, Christopher A; Ingram, Emily R; Rodwell, Leanne T; Borg, Brigitte M

    2017-10-01

    Spirometry training courses are provided by health services and training organizations to enable widespread use of spirometry testing for patient care or for monitoring health. The primary outcome of spirometry training courses should be to enable participants to perform spirometry to international best practice, including testing of subjects, quality assurance and interpretation of results. Where valid results are not achieved or quality assurance programmes identify errors in devices, participants need to be able to adequately manage these issues in accordance with best practice. It is important that potential participants are confident in the integrity of the course they attend and that the course meets their expectations in terms of training. This position statement lists the content that the Australian and New Zealand Society of Respiratory Science (ANZSRS) has identified as required in a spirometry training course to adequately meet the primary outcomes mentioned above. The content requirements outlined in this position statement are based on the current international spirometry standards set out by the American Thoracic Society and European Respiratory Society. Furthermore, recommendations around course delivery for theoretical and practical elements of spirometry testing and post-course assessment are outlined in this statement. © 2017 The Authors. Respirology published by John Wiley & Sons Australia, Ltd on behalf of Asian Pacific Society of Respirology.

  3. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    Science.gov (United States)

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  4. Assessment of spirometry and impulse oscillometry in relation to asthma control.

    Science.gov (United States)

    Manoharan, Arvind; Anderson, William J; Lipworth, Joseph; Lipworth, Brian J

    2015-02-01

    Guidelines advocate the use of spirometry to assess pulmonary function in asthmatic patients. Commonly used measures include forced expiratory volume in 1 s (FEV1), forced expiratory ratio (FEV1/FVC), and forced mid-expiratory flow between 25 and 75 % of forced vital capacity (FEF25-75). Impulse oscillometry (IOS) is an effort-independent test performed during tidal breathing. IOS may be used to assess the total and central airway resistance at 5 Hz (R5) and 20 Hz (R20), respectively, and hence derive the peripheral airway resistance from the difference (R5-R20). We compared spirometry and IOS as tests of global airway function (i.e., FEV1, FEV1/FVC, R5) and putative measures of small airways function (i.e., FEF25-75, R5-R20) and their relationship to oral steroid and short-acting beta-agonist (SABA) use as surrogates for long-term asthma control. Spirometry and IOS measurements from physician-diagnosed asthmatics were linked to a health informatics database for oral steroid and SABA use 1 year prior to the index measurements. Four hundred forty-two patients had both spirometry and IOS, mean FEV1 = 86 % predicted, 94 % on ICS, median dose 800 µg/day. IOS and spirometry measures were equally predictive of impaired asthma control for both oral steroid and SABA use. For oral steroid use, the adjusted odds ratio, OR (95 % CI) is as follows: FEV1 150 %: 1.91(1.25-2.95), p = 0.003; and R5-R20 > 0.1 kPa L(-1) s 1.73(1.12-2.66), p = 0.013. For SABA use, the adjusted OR (95 % CI) is as follows: FEV1 150 %: 1.76(1.18-2.63), p = 0.006; and R5-R20 > 0.1 kPa L(-1) s: 2.94(1.94-4.46), p Spirometry or IOS measurements were equally useful as potential markers of asthma control in persistent asthmatic patients.

  5. Effectiveness of a structured motivational intervention including smoking cessation advice and spirometry information in the primary care setting: the ESPITAP study

    Directory of Open Access Journals (Sweden)

    Martin-Lujan Francisco

    2011-11-01

    Full Text Available Abstract Background There is current controversy about the efficacy of smoking cessation interventions that are based on information obtained by spirometry. The objective of this study is to evaluate the effectiveness in the primary care setting of structured motivational intervention to achieve smoking cessation, compared with usual clinical practice. Methods Design Multicentre randomized clinical trial with an intervention and a control group. Setting 12 primary care centres in the province of Tarragona (Spain. Subjects of study 600 current smokers aged between 35 and 70 years with a cumulative habit of more than 10 packs of cigarettes per year, attended in primary care for any reason and who did not meet any of the exclusion criteria for the study, randomly assigned to structured intervention or standard clinical attention. Intervention Usual advice to quit smoking by a general practitioner as well as a 20-minute personalized visit to provide detailed information about spirometry results, during which FEV1, FVC, FEF 25-75% and PEF measurements were discussed and interpreted in terms of theoretical values. Additional information included the lung age index (defined as the average age of a non-smoker with the same FEV1 as the study participant, comparing this with the chronological age to illustrate the pulmonary deterioration that results from smoking. Measurements Spirometry during the initial visit. Structured interview questionnaire administered at the primary care centre at the initial visit and at 12-month follow-up. Telephone follow-up interview at 6 months. At 12-month follow-up, expired CO was measured in patients who claimed to have quit smoking. Main variables Smoking cessation at 12 months. Analysis Data will be analyzed on the basis of "intention to treat" and the unit of analysis will be the individual smoker. Expected results Among active smokers treated in primary care we anticipate significantly higher smoking cessation in the

  6. Superconductors with excess quasiparticles

    International Nuclear Information System (INIS)

    Elesin, V.F.; Kopaev, Y.V.

    1981-01-01

    This review presents a systematic kinetic theory of nonequilibrium phenomena in superconductors with excess quasiparticles created by electromagnetic or tunnel injection. The energy distributions of excess quasiparticles and of nonequilibrium phonons, dependence of the order parameter on the power and frequency (or intensity) of the electromagnetic field, magnetic properties of nonequilibrium superconductors, I-V curves of superconductor-insulator-superconductor junctions, and other properties are described in detail. The stability of superconducting states far from thermodynamic equilibrium is investigated and it is shown that characteristic instabilities leading to the formation of nonuniform states of a new type or phase transitions of the first kind are inherent to superconductors with excess quasiparticles. The results are compared with experimental data

  7. Excess wind power

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2005-01-01

    Expansion of wind power is an important element in Danish climate change abatement policy. Starting from a high penetration of approx 20% however, momentary excess production will become an important issue in the future. Through energy systems analyses using the EnergyPLAN model and economic...... analyses it is analysed how excess productions are better utilised; through conversion into hydrogen of through expansion of export connections thereby enabling sales. The results demonstrate that particularly hydrogen production is unviable under current costs but transmission expansion could...

  8. Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung

    International Nuclear Information System (INIS)

    Lu Wei; Low, Daniel A.; Parikh, Parag J.; Nystrom, Michelle M.; El Naqa, Issam M.; Wahab, Sasha H.; Handoko, Maureen; Fooshee, David; Bradley, Jeffrey D.

    2005-01-01

    An important consideration in four-dimensional CT scanning is the selection of a breathing metric for sorting the CT data and modeling internal motion. This study compared two noninvasive breathing metrics, spirometry and abdominal height, against internal air content, used as a surrogate for internal motion. Both metrics were shown to be accurate, but the spirometry showed a stronger and more reproducible relationship than the abdominal height in the lung. The abdominal height was known to be affected by sensor placement and patient positioning while the spirometer exhibited signal drift. By combining these two, a normalization of the drift-free metric to tidal volume may be generated and the overall metric precision may be improved

  9. Spirometry utilisation among Danish adults initiating medication targeting obstructive lung disease

    DEFF Research Database (Denmark)

    Koefoed, Mette

    2015-01-01

    performed. RESULTS: A total of 40,969 adults initiated medication targeting obstructive lung medication in 2008 in Denmark. The mean age of the cohort was 55.6 years (SD18.7) and approximately half of the mediations users had spirometry test performed. Initiating several types of medication targeting......UNLABELLED: This PhD thesis was written during my employment at the Research Unit of General Practice in Odense, University of Southern Denmark. It comprises an overview and three papers, all published or submitted for publication in international peer-reviewed scientific journals. BACKGROUND: Non...... with pharmacotherapy targeting obstructive lung disease and only few have additional tests conducted, although the predictive value of respiratory symptoms for diagnosing obstructive lung disease has proven to be low. Spirometry is recommended as the gold standard for confirming obstructive lung disease, and testing...

  10. [Further examination of COPD using spirometry, respiratory function test, and impulse oscillometry].

    Science.gov (United States)

    Tanaka, Hiroshi; Fujii, Masaru; Kitada, Junya

    2011-10-01

    Spirometry is essential for diagnosis and staging of chronic obstructive pulmonary disease (COPD). Characteristic of physiological change of small airways in COPD is heterogeneous distribution of small airway narrowing, resulting in air-trapping and nonhomogeneous ventilation. FEF25-75, residual volume/total lung capacity, delta N2 in phase III slope of single breath N2 washout test, closing volume, static and dynamic compliance, and carbon monoxide diffusing capacity (transfer factor) are measured for detecting small airways disease. Impulse oscillometry is also useful for assessment of small airways disease, especially indices of frequent resonance (Fres) and frequent dependent of resistance change of R5-R20; resistance at 5 Hz minus resistance at 20 Hz. Impulse oscillometry seems to have a complemental role of spirometry in managing COPD.

  11. Spirometry Reference Equations from the HCHS/SOL (Hispanic Community Health Study/Study of Latinos).

    Science.gov (United States)

    LaVange, Lisa; Davis, Sonia M; Hankinson, John; Enright, Paul; Wilson, Rebbecca; Barr, R Graham; Aldrich, Thomas K; Kalhan, Ravi; Lemus, Hector; Ni, Ai; Smith, Lewis J; Talavera, Gregory A

    2017-10-15

    Accurate reference values for spirometry are important because the results are used for diagnosing common chronic lung diseases such as asthma and chronic obstructive pulmonary disease, estimating physiologic impairment, and predicting all-cause mortality. Reference equations have been established for Mexican Americans but not for others with Hispanic/Latino backgrounds. To develop spirometry reference equations for adult Hispanic/Latino background groups in the United States. The HCHS/SOL (Hispanic Community Health Study/Study of Latinos) recruited a population-based probability sample of 16,415 Hispanics/Latinos aged 18-74 years living in the Bronx, Chicago, Miami, and San Diego. Participants self-identified as being of Puerto Rican, Cuban, Dominican, Mexican, or Central or South American background. Spirometry was performed using standardized methods with central quality control monitoring. Spirometric measures from a subset of 6,425 never-smoking participants without respiratory symptoms or disease were modeled as a function of sex, age, height, and Hispanic/Latino background to produce background-specific reference equations for the predicted value and lower limit of normal. Dominican and Puerto Rican Americans had substantially lower predicted and lower limit of normal values for FVC and FEV 1 than those in other Hispanic/Latino background groups and also than Mexican American values from NHANES III (Third National Health and Nutrition Examination Survey). For patients of Dominican and Puerto Rican background who present with pulmonary symptoms in clinical practice, use of background-specific spirometry reference equations may provide more appropriate predicted and lower limit of normal values, enabling more accurate diagnoses of abnormality and physiologic impairment.

  12. The value of spirometry and exercise challenge test to diagnose and monitor children with asthma.

    Science.gov (United States)

    van den Wijngaart, Lara S; Roukema, Jolt; Merkus, Peter Jfm

    2015-03-01

    Asthma is defined as a chronic inflammatory disease of the airways with characteristic symptoms including recurrent episodes of wheezing, breathlessness, chest tightness, and coughing. It may result in abnormalities of ventilator function, which can be assessed by different pulmonary function tests. In this case report, we present a 15-year-old boy with asthma and illustrate the value and limitations of spirometry and exercise challenge test in daily practice.

  13. Disposition of excess material

    International Nuclear Information System (INIS)

    Hall, J.C.

    1978-01-01

    This paper reviews briefly the means available to an enrichment customer to dispose of excess material scheduled for delivery under a fixed-commitment contract, other than through termination of the related separative work. The methods are as follows: (1) sales; (2) use in facilities covered by other DOE contracts; and (3) assignment

  14. HIV Excess Cancers JNCI

    Science.gov (United States)

    In 2010, an estimated 7,760 new cancers were diagnosed among the nearly 900,000 Americans known to be living with HIV infection. According to the first comprehensive study in the United States, approximately half of these cancers were in excess of what wo

  15. Excess Sodium Tetraphenylborate and Intermediates Decomposition Studies

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, M.J.

    1998-12-07

    The stability of excess amounts of sodium tetraphenylborate (NaTPB) in the In-Tank Precipitation (ITP) facility depends on a number of variables. Concentration of palladium, initial benzene, and sodium ion as well as temperature provide the best opportunities for controlling the decomposition rate. This study examined the influence of these four variable on the reactivity of palladium-catalyzed sodium tetraphenylborate decomposition. Also, single effects tests investigated the reactivity of simulants with continuous stirring and nitrogen ventilation, with very high benzene concentrations, under washed sodium concentrations, with very high palladium concentrations, and with minimal quantities of excess NaTPB.

  16. Spirometry in Greenland: a cross-sectional study on patients treated with medication targeting obstructive pulmonary disease.

    Science.gov (United States)

    Nielsen, Lasse Overballe; Olsen, Sequssuna; Jarbøl, Dorte Ejg; Pedersen, Michael Lynge

    2016-01-01

    Chronic obstructive pulmonary disease (COPD) is globally increasing in frequency and is expected to be the third largest cause of death by 2020. Smoking is the main risk factor of developing COPD. In Greenland, more than half of the adult population are daily smokers, and COPD may be common. International guidelines recommend the usage of spirometry as a golden standard for diagnosing COPD. The current number of spirometries performed among patients treated with medication targeting obstructive pulmonary disease in Greenland remains unexplored. To estimate the prevalence of patients aged 50 years or above treated with medication targeting obstructive pulmonary disease and the extent to which spirometry was performed among them within 2 years. An observational, cross-sectional study based on the review of data obtained from electronic medical records in Greenland was performed. The inclusion criterion was that patients must have been permanent residents aged 50 years or above who had medication targeting obstructive pulmonary disease prescribed within a period of 15 months prior to data extraction. A full review of electronic patient records was done on each of the identified users of medication targeting obstructive pulmonary disease. Information on age, gender, town and spirometry was registered for each patient within the period from October 2013 to October 2015. The prevalence of patients treated with medication targeting obstructive pulmonary disease aged 50 years or above was 7.9%. Of those, 34.8% had spirometry performed within 2 years and 50% had a forced expiratory volume (1 sec)/ forced vital capacity (FEV1/FVC) under 70% indicating obstructive pulmonary disease. The use of medication targeting obstructive pulmonary disease among patients over 50 years old is common in Greenland. About one third of the patients had a spirometry performed within 2 years. To further increase spirometry performance, it is recommended to explore possible barriers in health

  17. Asthma, chronic obstructive pulmonary disease, or both? Diagnostic labeling and spirometry in primary care patients aged 40 years or more

    Directory of Open Access Journals (Sweden)

    Melbye H

    2011-11-01

    Full Text Available Hasse Melbye1, Elin Drivenes1, Lene G Dalbak2, Tone Leinan1, Svein Høegh-Henrichsen2, Anders Østrem21General Practice Research Unit, Department of Community Medicine, University of Tromsø, 2General Practice Research Unit, Department of Health and Society, University of Oslo, NorwayAims: To describe symptoms and lung function in patients registered with asthma or chronic obstructive pulmonary disease (COPD in primary care and to examine how spirometry findings fit with general practitioners’ (GPs diagnoses.Methods: Patients aged ≥40 years with a diagnosis of asthma or COPD registered in the electronic medical record during the previous 5 years were recruited at seven GP offices in Norway in 2009–2010. Registered diagnosis, spirometry results, comorbidity, and reported symptoms were compared.Results: Among 376 patients, 62% were women. Based on Global Initiative for Chronic Obstructive Lung Diseases criteria, a spirometry diagnosis of COPD could be made in 68.1% of the patients with a previous COPD diagnosis and in 17.1% of those diagnosed with asthma only (P < 0.001. The κ agreement between last clinical diagnosis of COPD and COPD based on spirometry was 0.50. A restrictive spirometry pattern was found in 19.4% and more frequently in patients diagnosed with both asthma and COPD (23.9% than in patients diagnosed with COPD only (6.8%, P = 0.003.Conclusion: The ability of GPs to differentiate between asthma and COPD seems to have considerably improved during the last decade, probably due to the dissemination of spirometry and guidelines for COPD diagnosis. A diagnosis of COPD that cannot be confirmed by spirometry represents a challenge in clinical practice, in particular when a restrictive pattern on spirometry is found.Keywords: asthma, COPD, diagnosis, primary care

  18. Modern Spirometry Supports Anesthetic Management in Small Animal Clinical Practice: A Case Series.

    Science.gov (United States)

    Calice, Ivana; Moens, Yves

    2016-01-01

    Modern spirometry, like no other monitoring technique, allows insight into breath-to-breath respiratory mechanics. Spirometers continuously measure volume, airway pressure, and flow while calculating and continuously displaying respiratory system compliance and resistance in the form of loops. The aim of this case series is to show how observation of spirometric loops, similar to electrocardiogram or CO2 curve monitoring, can improve safety of anesthetic management in small animals. Spirometric monitoring cases described in this case series are based on use of the anaesthesia monitor Capnomac Ultima with a side stream spirometry sensor. The cases illustrate how recognition and understanding of spirometric loops allows for easy diagnosis of iatrogenic pneumothorax, incorrect ventilator settings, leaks in the system, kinked or partially obstructed endotracheal tube, and spontaneous breathing interfering with intermittent positive-pressure ventilation. The case series demonstrates the potential of spirometry to improve the quality and safety of anesthetic management, and, hence, its use can be recommended during intermittent positive-pressure ventilation and procedures in which interference with ventilation can be expected.

  19. Measurement of total lung capacity : a comparison of spiral CT and spirometry

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Park, Kyung Ju; Lee, Eh Hyung; Yune, Heun Young; Suh, Jung Ho; Choe, Kyu Ok; Lim, Tae Hwan; Chung, In Hyuk

    1996-01-01

    To determine the potential of spiral CT as a functional imaging modality of the lung aside from its proven value in morphological depiction. Spiral CT scan was performed in ten normal female and nine normal male adults (mean age: 39, height: 163 cm, weight: 62 kg ) after single full breath-holding. Three dimensional lung images were reconstructed(minimal threshold value: -1,000HU, maximal threshold values: -150, 250, -350, -450 HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT was compared with TLV obtained by spirometry. Mean TLV measured by spirometry was 5.62L and TLV measured by CT at maximal threshold values of -150, -250, -350, and -450 HU was 5.53, 5.33, 5.15, and 4.98L, respectively. Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5%) were statistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 095, and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lung volume(r=0.99, standard error=0.034L in all) were seen. TLV measured by spiral CT closely approximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function

  20. A Study of the Usability of Ergonomic Camera Vest Based on Spirometry Parameters

    Directory of Open Access Journals (Sweden)

    Shirazeh Arghami

    2017-12-01

    Full Text Available Background: Being a cameraman is one of those occupations that expose people to musculoskeletal disorders (MSDs. Therefore, control measures should be taken to protect cameramen’s health. To solve the given problem, a vest was designed for cameramen to prevent MSDs by reducing the pressure and contact stress while carrying the camera on their shoulder. However, the usability of vest had to be considered. The aim of this study was to determine the usability of the proposed vest using the spirometry parameters indicator. Methods: In this experimental study, 120 spirometry experiments were conducted with 40 male volunteer subjects with and without designed vest. Data were analyzed using SPSS- 16 with dependent t-test, at 0.05 significance level. Results: Based on the spirometry results, there is a significant difference between Forced Vital Capacity (FVC, Forced Expiratory Volume (FEV1 and heart rate in activity with and without vest (p<0.001. Conclusion: The results suggest that the promising impact of this invention on the health of cameramen makes this domestically designed camera vest a good option for mass production.

  1. Practical surrogate marker of pulmonary dysanapsis by simple spirometry: an observational case-control study in primary care.

    Science.gov (United States)

    Shiota, Satomi; Ichikawa, Masako; Suzuki, Kazuhiro; Fukuchi, Yoshinosuke; Takahashi, Kazuhisa

    2015-03-26

    We see patients who present with spirometry airflow limitation despite their forced expiratory volume in one second (FEV1) as well as forced vital capacity (FVC) to be supernormal (FEV1/FVC spirometry conditions (results measured with spirometry) could be suitably used as a practical surrogate marker of pulmonary dysanapsis: the condition of disproportionate but physiologically normal growth between airways and lung parenchyma. We compared the conventional surrogate marker of dysanapsis, maximum mid-expiratory flow to FVC (MMF/FVC), in SUBJECTS (FEV1/FVC spirometry results with SUBJECTS) (n = 55), and in CONTROLS (age- and height- matched, normal spirometry results) (n = 25). Next we added imaging analysis to evaluate the relationship between the cross sectional airway luminal area (X-Ai) and the lung volume results among the three groups. The MMF/FVC was significantly lower in SUBJECTS and in EMPHYSEMA compared to CONTROLS. However, percent predicted peak expiratory flow (%PEFR) was significantly lower only in SUBJECTS and not in EMPHYSEMA compared to CONTROLS. The ratio of the X-Ai of the trachea and right apical bronchus to lung volume was significantly lower in SUBJECTS compared to CONTROLS. The simple spirometry conditions in SUBJECTS are highly suggestive of practical surrogate marker of pulmonary dysanapsis. Awareness of this concept would help to attenuate the risk of overdiagnosis of obstructive pulmonary disease.

  2. Effects of a 12-month multi-faceted mentoring intervention on knowledge, quality, and usage of spirometry in primary care: a before-and-after study.

    Science.gov (United States)

    Gupta, Samir; Moosa, Dilshad; MacPherson, Ana; Allen, Christopher; Tamari, Itamar E

    2016-04-21

    Asthma is among the most common chronic diseases in adults. International guidelines have emphasized the importance of regular spirometry for asthma control evaluation. However, spirometry use in primary care remains low across jurisdictions. We sought to design and evaluate a knowledge translation intervention to address both the poor quality of spirometry and the underuse of spirometry in primary care. We designed a 1-year intervention consisting of initial interactive education and hands-on training followed by unstructured peer expert mentoring (through an online portal, email, telephone, videoconference, fax, and/or in-person). We recruited physician and allied health mentees from across primary care sites in Ontario, Canada. We compared spirometry-related knowledge immediately before and after the 1-year intervention period and the quality of spirometry testing and the usage of spirometry in patients with asthma in the year before and the year of the intervention. Seven of 10 (70 %) invited sites participated, including 25/90 (28 %) invited allied health mentees and 23/68 (34 %) invited physician mentees. We recruited 7 physician mentors and 4 allied health mentors to form 3 mentor-mentee pods. Spirometry knowledge scores increased from 21.4 +/- 3.1 pre- to 27.3 +/- 3.5 (out of 35) (p Spirometry acceptability and repeatability criteria were met by 59/191 (30.9 %) spirometries and 86/193 (44.6 %) spirometries [odds ratio 1.7 (1.0, 3.0)], in the pre-intervention and intervention periods, respectively. Spirometry was ordered in 75/512 (14.6 %) and 129/336 (38.4 %) respiratory visits (p spirometry in real world primary care settings. A future controlled study should assess the impact of this intervention on patient outcomes, its cost-effectiveness, and its sustainability.

  3. Spirometry-Assisted High Resolution Chest Computed Tomography in Children: Is it Worth the Effort?

    Science.gov (United States)

    Otjen, Jeffrey Parke; Swanson, Jonathan Ogden; Oron, Assaf; DiBlasi, Robert M; Swortzel, Tim; van Well, Jade Adriana Marie; Gommers, Eva Anna Elisabeth; Rosenfeld, Margaret

    Image quality of high resolution chest computed tomographies (HRCTs) depends on adequate breath holds at end inspiration and end expiration. We hypothesized that implementation of spirometry-assisted breath holds in children undergoing HRCTs would improve image quality over that obtained with voluntary breath holds by decreasing motion artifact and atelectasis. This is a retrospective case-control study of HRCTs obtained at a tertiary care children's hospital before and after implementation of a spirometry-assisted CT protocol, in which children ≥8 years of age are first trained in supine slow vital capacity maneuvers and then repeat the maneuvers in the CT scanner, coached by a respiratory therapist. Spirometry-assisted CT scans (cases) were matched by age, gender and diagnosis (cystic fibrosis vs other) to CT scans obtained with voluntary breath holds in the 6 years before implementation of the spirometry assistance protocol (controls), and evaluated by 2 blinded pediatric radiologists. Among both cases and controls (N = 50 each), 10 carried the diagnosis of cystic fibrosis and 40 had other diagnoses. Mean age was 12.9 years (range: 7.5-20.1) among cases and 13.0 (7.1-19.7) among controls. Mean (SD) inspiratory image density among cases was -852 (37) Hounsfield units (HU) and -828 (43) among controls (p = 0.006). Mean (SD) expiratory image density was -629 (95) HU among cases and -688 (83) HU among controls (p = 0.002). Mean (SD) change in image density between inspiratory and expiratory images was +222 (85) HU among cases and +140 (76) HU among controls (p 0.80). Atelectasis was present on inspiratory images in 8 cases and 9 controls and on expiratory images in 9 cases and 10 controls (p > 0.80). Spirometry-assisted CTs had a significantly greater difference in lung density between inspiratory and expiratory scans than those performed with voluntary breath holds, likely improving the ability to detect air trapping. No appreciable difference in image quality

  4. The effect of incentive spirometry on postoperative pulmonary function following laparotomy: a randomized clinical trial.

    Science.gov (United States)

    Tyson, Anna F; Kendig, Claire E; Mabedi, Charles; Cairns, Bruce A; Charles, Anthony G

    2015-03-01

    Changes in pulmonary dynamics following laparotomy are well documented. Deep breathing exercises, with or without incentive spirometry, may help counteract postoperative decreased vital capacity; however, the evidence for the role of incentive spirometry in the prevention of postoperative atelectasis is inconclusive. Furthermore, data are scarce regarding the prevention of postoperative atelectasis in sub-Saharan Africa. To determine the effect of the use of incentive spirometry on pulmonary function following exploratory laparotomy as measured by forced vital capacity (FVC). This was a single-center, randomized clinical trial performed at Kamuzu Central Hospital, Lilongwe, Malawi. Study participants were adult patients who underwent exploratory laparotomy and were randomized into the intervention or control groups (standard of care) from February 1 to November 30, 2013. All patients received routine postoperative care, including instructions for deep breathing and early ambulation. We used bivariate analysis to compare outcomes between the intervention and control groups. Adult patients who underwent exploratory laparotomy participated in postoperative deep breathing exercises. Patients in the intervention group received incentive spirometers. We assessed pulmonary function using a peak flow meter to measure FVC in both groups of patients. Secondary outcomes, such as hospital length of stay and mortality, were obtained from the medical records. A total of 150 patients were randomized (75 in each arm). The median age in the intervention and control groups was 35 years (interquartile range, 28-53 years) and 33 years (interquartile range, 23-46 years), respectively. Men predominated in both groups, and most patients underwent emergency procedures (78.7% in the intervention group and 84.0% in the control group). Mean initial FVC did not differ significantly between the intervention and control groups (0.92 and 0.90 L, respectively; P=.82 [95% CI, 0.52-2.29]). Although

  5. Excessive crying in infants

    Directory of Open Access Journals (Sweden)

    Ricardo Halpern

    2016-05-01

    Conclusion: Excessive crying in the early months is a prevalent symptom; the pediatrician's attention is necessary to understand and adequately manage the problem and offer support to exhausted parents. The prescription of drugs of questionable action and with potential side effects is not a recommended treatment, except in extreme situations. The effectiveness of dietary treatments and use of probiotics still require confirmation. There is incomplete evidence regarding alternative treatments such as manipulation techniques, acupuncture, and use of the herbal supplements and behavioral interventions.

  6. ACTIVATION PARAMETERS AND EXCESS THERMODYANAMIC ...

    African Journals Online (AJOL)

    Applying these data, viscosity-B-coefficients, activation parameters (Δμ10≠) and (Δμ20≠) and excess thermodynamic functions, viz., excess molar volume (VE), excess viscosity, ηE and excess molar free energy of activation of flow, (GE) were calculated. The value of interaction parameter, d, of Grunberg and Nissan ...

  7. A home monitoring program including real-time wireless home spirometry in idiopathic pulmonary fibrosis: a pilot study on experiences and barriers.

    Science.gov (United States)

    Moor, C C; Wapenaar, M; Miedema, J R; Geelhoed, J J M; Chandoesing, P P; Wijsenbeek, M S

    2018-05-29

    In idiopathic pulmonary fibrosis (IPF), home monitoring experiences are limited, not yet real-time available nor implemented in daily care. We evaluated feasibility and potential barriers of a new home monitoring program with real-time wireless home spirometry in IPF. Ten patients with IPF were asked to test this home monitoring program, including daily home spirometry, for four weeks. Measurements of home and hospital spirometry showed good agreement. All patients considered real-time wireless spirometry useful and highly feasible. Both patients and researchers suggested relatively easy solutions for the identified potential barriers regarding real-time home monitoring in IPF.

  8. Inflammatory Responses, Spirometry, and Quality of Life in Subjects With Bronchiectasis Exacerbations.

    Science.gov (United States)

    Guan, Wei-Jie; Gao, Yong-Hua; Xu, Gang; Lin, Zhi-Ya; Tang, Yan; Li, Hui-Min; Lin, Zhi-Min; Jiang, Mei; Zheng, Jin-Ping; Chen, Rong-Chang; Zhong, Nan-Shan

    2015-08-01

    Bronchiectasis exacerbations are critical events characterized by worsened symptoms and signs (ie, cough frequency, sputum volume, malaise). Our goal was to examine variations in airway and systemic inflammation, spirometry, and quality of life during steady state, bronchiectasis exacerbations, and convalescence (1 week following a 2-week antibiotic treatment) to determine whether potentially pathogenic microorganisms, including Pseudomonas aeruginosa, were associated with poorer conditions during bronchiectasis exacerbations. Peripheral blood and sputum were sampled to detect inflammatory mediators and bacterial densities. Spirometry and quality of life (St George Respiratory Questionnaire [SGRQ]) were assessed during the 3 stages. Forty-eight subjects with bronchiectasis (43.2 ± 14.2 y of age) were analyzed. No notable differences in species and density of potentially pathogenic microorganisms were found during bronchiectasis exacerbations. Except for CXCL8 and tumor necrosis factor alpha (TNF-α), serum inflammation was heightened during bronchiectasis exacerbations and recovered during convalescence. Even though sputum TNF-α was markedly higher during bronchiectasis exacerbations and remained heightened during convalescence, the variations in miscellaneous sputum markers were unremarkable. Bronchiectasis exacerbations were associated with notably higher SGRQ symptom and total scores, which recovered during convalescence. FVC, FEV1, and maximum mid-expiratory flow worsened during bronchiectasis exacerbations (median change from baseline of -2.2%, -0.8%, and -1.3%) and recovered during convalescence (median change from baseline of 0.6%, 0.7%, and -0.7%). Compared with no bacterial isolation, potentially pathogenic microorganism or P. aeruginosa isolation at baseline did not result in poorer clinical condition during bronchiectasis exacerbations. Bronchiectasis exacerbations are characterized by heightened inflammatory responses and poorer quality of life and

  9. The diagnosis of COPD in primary care; gender differences and the role of spirometry.

    Science.gov (United States)

    Roberts, N J; Patel, I S; Partridge, M R

    2016-02-01

    Females with exacerbations of Chronic Obstructive Pulmonary Disease now account for one half of all hospital admissions for that condition and rates have been increasing over the last few decades. Differences in presentations of disease between genders have been shown in several conditions and this study explores whether there are inter gender biases in probable diagnoses in those suspected to have COPD. 445 individuals with a provisional diagnosis by their General Practitioner of "suspected COPD" or "definite COPD" were referred to a community Respiratory Assessment unit (CRAU) for tests including spirometry. Gender, demographics, respiratory symptoms and respiratory medical history were recorded. The provisional diagnoses were compared with the final diagnosis made after spirometry and respiratory specialist nurse review and the provisional diagnosis was either confirmed as correct or refuted as unlikely. Significantly more men (87.5%) had their diagnosis of "definite COPD" confirmed compared to 73.9% of women (p = 0.021). When the GP suggested a provisional diagnosis of "suspected COPD" (n = 265) at referral, this was confirmed in 60.9% of men and only 43.2% of women (p = 0.004). There was a different symptom pattern between genders with women being more likely to report allergies, symptoms starting earlier in life, and being less likely than men to report breathlessness as the main symptom. These results may suggest a difference between genders in some of the clinical features of COPD and a difference in likelihood of a GPs provisional diagnosis of COPD being correct. The study reiterates the absolute importance of spirometry in the diagnosis of COPD. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Spirometry as a motivational tool to improve smoking cessation rates: a systematic review of the literature.

    Science.gov (United States)

    Wilt, Timothy J; Niewoehner, Dennis; Kane, Robert L; MacDonald, Roderick; Joseph, Anne M

    2007-01-01

    Obtaining spirometric testing and providing those results to individuals who smoke has been advocated as a motivational tool to improve smoking cessation. However, its effectiveness is not known. We conducted a systematic review to determine if this approach improves rates of smoking cessation. Data sources included MEDLINE (1966 to October 2005), the Cochrane Library, and experts in the field. Eligible randomized controlled trials (RCTs) enrolled at least 25 smokers per arm, evaluated spirometry with associated counseling or in combination with other treatments, followed subjects at least 6 months, and provided smoking abstinence rates. Results from nonrandomized studies also were summarized. The primary outcome was patient-reported long-term (at least 6 months) sustained abstinence with biological validation. Additional outcomes included self-reported abstinence and point-prevalence abstinence. Seven RCTs (N = 6,052 subjects) met eligibility criteria. Follow-up duration ranged from 9 to 36 months. In six trials, the intervention group received concomitant treatments previously demonstrated to increase cessation independently. The range of abstinence was 3%-14% for control subjects and 7%-39% among intervention groups, statistically significantly in favor of intervention in four studies. The only RCT that assessed the independent contribution of spirometry in combination with counseling demonstrated a nonsignificant 1% improvement in patient-reported point-prevalence abstinence at 12 months in the group that received spirometry plus counseling versus counseling alone (6.5% versus 5.5%). Findings from observational studies were mixed, and the lack of controls makes interpretation problematic. Available evidence is insufficient to determine whether obtaining spirometric values and providing that information to patients improves smoking cessation compared with other smoking cessation methods. Spirometric values are of limited benefit as a predictor of smoking

  11. Challenges in Collating Spirometry Reference Data for South-Asian Children: An Observational Study

    Science.gov (United States)

    Lum, Sooky; Bountziouka, Vassiliki; Quanjer, Philip; Sonnappa, Samatha; Wade, Angela; Beardsmore, Caroline; Chhabra, Sunil K.; Chudasama, Rajesh K.; Cook, Derek G.; Harding, Seeromanie; Kuehni, Claudia E.; Prasad, K. V. V.; Whincup, Peter H.; Lee, Simon; Stocks, Janet

    2016-01-01

    Availability of sophisticated statistical modelling for developing robust reference equations has improved interpretation of lung function results. In 2012, the Global Lung function Initiative(GLI) published the first global all-age, multi-ethnic reference equations for spirometry but these lacked equations for those originating from the Indian subcontinent (South-Asians). The aims of this study were to assess the extent to which existing GLI-ethnic adjustments might fit South-Asian paediatric spirometry data, assess any similarities and discrepancies between South-Asian datasets and explore the feasibility of deriving a suitable South-Asian GLI-adjustment. Methods Spirometry datasets from South-Asian children were collated from four centres in India and five within the UK. Records with transcription errors, missing values for height or spirometry, and implausible values were excluded(n = 110). Results Following exclusions, cross-sectional data were available from 8,124 children (56.3% male; 5–17 years). When compared with GLI-predicted values from White Europeans, forced expired volume in 1s (FEV1) and forced vital capacity (FVC) in South-Asian children were on average 15% lower, ranging from 4–19% between centres. By contrast, proportional reductions in FEV1 and FVC within all but two datasets meant that the FEV1/FVC ratio remained independent of ethnicity. The ‘GLI-Other’ equation fitted data from North India reasonably well while ‘GLI-Black’ equations provided a better approximation for South-Asian data than the ‘GLI-White’ equation. However, marked discrepancies in the mean lung function z-scores between centres especially when examined according to socio-economic conditions precluded derivation of a single South-Asian GLI-adjustment. Conclusion Until improved and more robust prediction equations can be derived, we recommend the use of ‘GLI-Black’ equations for interpreting most South-Asian data, although ‘GLI-Other’ may be more

  12. A Multiphase Non-Linear Mixed Effects Model: An Application to Spirometry after Lung Transplantation

    Science.gov (United States)

    Rajeswaran, Jeevanantham; Blackstone, Eugene H.

    2014-01-01

    In medical sciences, we often encounter longitudinal temporal relationships that are non-linear in nature. The influence of risk factors may also change across longitudinal follow-up. A system of multiphase non-linear mixed effects model is presented to model temporal patterns of longitudinal continuous measurements, with temporal decomposition to identify the phases and risk factors within each phase. Application of this model is illustrated using spirometry data after lung transplantation using readily available statistical software. This application illustrates the usefulness of our flexible model when dealing with complex non-linear patterns and time varying coefficients. PMID:24919830

  13. Hyperpolarized 3helium magnetic resonance ventilation imaging of the lung in cystic fibrosis: comparison with high resolution CT and spirometry

    International Nuclear Information System (INIS)

    McMahon, Colm J.; Dodd, Jonathan D.; Skehan, Stephen J.; Masterson, James B.; Hill, Catherine; Woodhouse, Neil; Wild, Jim M.; Fichele, Stan; Gallagher, Charles G.; Beek, Edwin J.R. van

    2006-01-01

    The purpose of this study was to compare hyperpolarized 3 helium magnetic resonance imaging ( 3 He MRI) of the lungs in adults with cystic fibrosis (CF) with high-resolution computed tomography (HRCT) and spirometry. Eight patients with stable CF prospectively underwent 3 He MRI, HRCT, and spirometry within 1 week. Three-dimensional (3D) gradient-echo sequence was used during an 18-s breath-hold following inhalation of hyperpolarized 3 He. Each lung was divided into six zones; 3 He MRI was scored as percentage ventilation per lung zone. HRCT was scored using a modified Bhalla scoring system. Univariate (Spearman rank) and multivariate correlations were performed between 3 He MRI, HRCT, and spirometry. Results are expressed as mean±SD (range). Spirometry is expressed as percent predicted. There were four men and four women, mean age=31.9±9 (20-46). Mean forced expiratory volume in 1 s (FEV) 1 =52%±29 (27-93). Mean 3 He MRI score=74%±25 (55-100). Mean HRCT score=48.8±24 (13.5-83). The correlation between 3 He MRI and HRCT was strong (R=±0.89, p 3 He MRI; 3 He MRI correlated better with FEV 1 and forced vital capacity (FVC) (R=0.86 and 0.93, p 3 He MRI correlates strongly with structural HRCT abnormalities and is a stronger correlate of spirometry than HRCT in CF. (orig.)

  14. Excessive crying in infants

    Directory of Open Access Journals (Sweden)

    Ricardo Halpern

    2016-05-01

    Full Text Available Objective: Review the literature on excessive crying in young infants, also known as infantile colic, and its effects on family dynamics, its pathophysiology, and new treatment interventions. Data source: The literature review was carried out in the Medline, PsycINFO, LILACS, SciELO, and Cochrane Library databases, using the terms “excessive crying,” and “infantile colic,” as well technical books and technical reports on child development, selecting the most relevant articles on the subject, with emphasis on recent literature published in the last five years. Summary of the findings: Excessive crying is a common symptom in the first 3 months of life and leads to approximately 20% of pediatric consultations. Different prevalence rates of excessive crying have been reported, ranging from 14% to approximately 30% in infants up to 3 months of age. There is evidence linking excessive crying early in life with adaptive problems in the preschool period, as well as with early weaning, maternal anxiety and depression, attention deficit hyperactivity disorder, and other behavioral problems. Several pathophysiological mechanisms can explain these symptoms, such as circadian rhythm alterations, central nervous system immaturity, and alterations in the intestinal microbiota. Several treatment alternatives have been described, including behavioral measures, manipulation techniques, use of medication, and acupuncture, with controversial results and effectiveness. Conclusion: Excessive crying in the early months is a prevalent symptom; the pediatrician's attention is necessary to understand and adequately manage the problem and offer support to exhausted parents. The prescription of drugs of questionable action and with potential side effects is not a recommended treatment, except in extreme situations. The effectiveness of dietary treatments and use of probiotics still require confirmation. There is incomplete evidence regarding alternative treatments

  15. The Virtual Diphoton Excess

    CERN Document Server

    Stolarski, Daniel

    2016-01-01

    Interpreting the excesses around 750 GeV in the diphoton spectra to be the signal of a new heavy scalar decaying to photons, we point out the possibility of looking for correlated signals with virtual photons. In particular, we emphasize that the effective operator that generates the diphoton decay will also generate decays to two leptons and a photon, as well as to four leptons, independently of the new resonance couplings to $Z\\gamma$ and $ZZ$. Depending on the relative sizes of these effective couplings, we show that the virtual diphoton component can make up a sizable, and sometimes dominant, contribution to the total $2\\ell \\gamma$ and $4\\ell$ partial widths. We also discuss modifications to current experimental cuts in order to maximize the sensitivity to these virtual photon effects. Finally, we briefly comment on prospects for channels involving other Standard Model fermions as well as more exotic decay possibilities of the putative resonance.

  16. Abundance, Excess, Waste

    Directory of Open Access Journals (Sweden)

    Rox De Luca

    2016-02-01

    Her recent work focuses on the concepts of abundance, excess and waste. These concerns translate directly into vibrant and colourful garlands that she constructs from discarded plastics collected on Bondi Beach where she lives. The process of collecting is fastidious, as is the process of sorting and grading the plastics by colour and size. This initial gathering and sorting process is followed by threading the components onto strings of wire. When completed, these assemblages stand in stark contrast to the ease of disposability associated with the materials that arrive on the shoreline as evidence of our collective human neglect and destruction of the environment around us. The contrast is heightened by the fact that the constructed garlands embody the paradoxical beauty of our plastic waste byproducts, while also evoking the ways by which those byproducts similarly accumulate in randomly assorted patterns across the oceans and beaches of the planet.

  17. Topiramate Induced Excessive Sialorrhea

    Directory of Open Access Journals (Sweden)

    Ersel Dag

    2015-11-01

    Full Text Available It is well-known that drugs such as clozapine and lithium can cause sialorrhea. On the other hand, topiramate has not been reported to induce sialorrhea. We report a case of a patient aged 26 who was given antiepileptic and antipsychotic drugs due to severe mental retardation and intractable epilepsy and developed excessive sialorrhea complaint after the addition of topiramate for the control of seizures. His complaints continued for 1,5 years and ended after giving up topiramate. We presented this case since it was a rare sialorrhea case induced by topiramate. Clinicians should be aware of the possibility of sialorrhea development which causes serious hygiene and social problems when they want to give topiramate to the patients using multiple drugs.

  18. General practice variation in spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease in Denmark: a population-based observational study.

    Science.gov (United States)

    Koefoed, Mette M; Søndergaard, Jens; Christensen, René dePont; Jarbøl, Dorte E

    2013-08-07

    Spirometry testing is essential to confirm an obstructive lung disease, but studies have reported that a large proportion of patients diagnosed with COPD or asthma have no history of spirometry testing. Also, it has been shown that many patients are prescribed medication for obstructive lung disease without a relevant diagnosis or spirometry test registered. General practice characteristics have been reported to influence diagnosis and management of several chronic diseases. However, these findings are inconsistent, and it is uncertain whether practice characteristics influence spirometry testing among patients receiving medication for obstructive lung disease. The aim of this study was therefore to examine if practice characteristics are associated with spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease. A national register-based cohort study was performed. All patients over 18 years receiving first-time prescriptions for medication targeting obstructive lung disease in 2008 were identified and detailed patient-specific data on sociodemographic status and spirometry tests were extracted. Information on practice characteristics like number of doctors, number of patients per doctor, training practice status, as well as age and gender of the general practitioners was linked to each medication user. Partnership practices had a higher odds ratio (OR) of performing spirometry compared with single-handed practices (OR 1.24, CI 1.09-1.40). We found a significant association between increasing general practitioner age and decreasing spirometry testing. This tendency was most pronounced among partnership practices, where doctors over 65 years had the lowest odds of spirometry testing (OR 0.25, CI 0.10-0.61). Training practice status was significantly associated with spirometry testing among single-handed practices (OR 1.40, CI 1.10-1.79). Some of the variation in spirometry testing among patients receiving

  19. The UK Quality and Outcomes Framework pay-for-performance scheme and spirometry: rewarding quality or just quantity? A cross-sectional study in Rotherham, UK

    Directory of Open Access Journals (Sweden)

    South Gail

    2009-06-01

    Full Text Available Abstract Background Accurate spirometry is important in the management of COPD. The UK Quality and Outcomes Framework pay-for-performance scheme for general practitioners includes spirometry related indicators within its COPD domain. It is not known whether high achievement against QOF spirometry indicators is associated with spirometry to BTS standards. Methods Data were obtained from the records of 3,217 patients randomly sampled from 5,649 patients with COPD in 38 general practices in Rotherham, UK. Severity of airflow obstruction was categorised by FEV1 (% predicted according to NICE guidelines. This was compared with clinician recorded COPD severity. The proportion of patients whose spirometry met BTS standards was calculated in each practice using a random sub-sample of 761 patients. The Spearman rank correlation between practice level QOF spirometry achievement and performance against BTS spirometry standards was calculated. Results Spirometry as assessed by clinical records was to BTS standards in 31% of cases (range at practice level 0% to 74%. The categorisation of airflow obstruction according to the most recent spirometry results did not agree well with the clinical categorisation of COPD recorded in the notes (Cohen's kappa = 0.34, 0.30 – 0.38. 12% of patients on COPD registers had FEV1 (% predicted results recorded that did not support the diagnosis of COPD. There was no association between quality, as measured by adherence to BTS spirometry standards, and either QOF COPD9 achievement (Spearman's rho = -0.11, or QOF COPD10 achievement (rho = 0.01. Conclusion The UK Quality and Outcomes Framework currently assesses the quantity, but not the quality of spirometry.

  20. Development of a spirometry T-score in the general population.

    Science.gov (United States)

    Lee, Sei Won; Kim, Hyun Kuk; Baek, Seunghee; Jung, Ji-Ye; Kim, Young Sam; Lee, Jae Seung; Lee, Sang-Do; Mannino, David M; Oh, Yeon-Mok

    2016-01-01

    Spirometry values may be expressed as T-scores in standard deviation units relative to a reference in a young, normal population as an analogy to the T-score for bone mineral density. This study was performed to develop the spirometry T-score. T-scores were calculated from lambda-mu-sigma-derived Z-scores using a young, normal age reference. Three outcomes of all-cause death, respiratory death, and COPD death were evaluated in 9,101 US subjects followed for 10 years; an outcome of COPD-related health care utilization (COPD utilization) was evaluated in 1,894 Korean subjects followed for 4 years. The probability of all-cause death appeared to remain nearly zero until -1 of forced expiratory volume in 1 second (FEV1) T-score but increased steeply where FEV1 T-score reached below -2.5. Survival curves for all-cause death, respiratory death, COPD death, and COPD utilization differed significantly among the groups when stratified by FEV1 T-score (Pspirometry T-score could predict all-cause death, respiratory death, COPD death, and COPD utilization.

  1. Lung volumes and airway resistance in patients with a possible restrictive pattern on spirometry.

    Science.gov (United States)

    Schultz, Kenia; D'Aquino, Luiz Carlos; Soares, Maria Raquel; Gimenez, Andrea; Pereira, Carlos Alberto de Castro

    2016-01-01

    Many patients with proportional reductions in FVC and FEV1 on spirometry show no reduction in TLC. The aim of this study was to evaluate the role that measuring lung volumes and airway resistance plays in the correct classification of patients with a possible restrictive pattern on spirometry. This was a prospective study involving adults with reduced FVC and FEV1, as well as an FEV1/FV(C) ratio within the predicted range. Restrictive lung disease (RLD) was characterized by TLC below the 5th percentile, as determined by plethysmography. Obstructive lung disease (OLD) was characterized by high specific airway resistance, significant changes in post-bronchodilator FEV1, or an FEF25-75% espirometria não têm CPT reduzida. O objetivo deste estudo foi avaliar o papel da medida dos volumes pulmonares e da resistência das vias aéreas para a classificação correta de pacientes com possível restrição à espirometria. Estudo prospectivo de adultos com CVF e VEF1 reduzidos e relação VEF1/CV(F) na faixa prevista. Distúrbio ventilatório restritivo (DVR) foi definido por CPT espirometria. A obstrução ao fluxo aéreo é comum nesses casos.

  2. Effect of e-Learning and Repeated Performance Feedback on Spirometry Test Quality in Family Practice: A Cluster Trial

    Science.gov (United States)

    Schermer, Tjard R.; Akkermans, Reinier P.; Crockett, Alan J.; van Montfort, Marian; Grootens-Stekelenburg, Joke; Stout, Jim W.; Pieters, Willem

    2011-01-01

    PURPOSE Spirometry has become an indispensable tool in primary care to exclude, diagnose, and monitor chronic respiratory conditions, but the quality of spirometry tests in family practices is a reason for concern. Aim of this study was to investigate whether a combination of e-learning and bimonthly performance feedback would improve spirometry test quality in family practices in the course of 1 year. METHODS Our study was a cluster trial with 19 family practices allocated to intervention or control conditions through minimization. Intervention consisted of e-learning and bimonthly feedback reports to practice nurses. Control practices received only the joint baseline workshop. Spirometry quality was assessed by independent lung function technicians. Two outcomes were defined, with the difference between rates of tests with 2 acceptable and repeatable blows being the primary outcome and the difference between rates of tests with 2 acceptable blows being the secondary outcome. We used multilevel logistic regression analysis to calculate odds ratios (ORs) for an adequate test in intervention group practices. RESULTS We analyzed 1,135 tests. Rate of adequate tests was 33% in intervention and 30% in control group practices (OR = 1.3; P=.605). Adequacy of tests did not differ between groups but tended to increase with time: OR = 2.2 (P = .057) after 3 and OR = 2.0 (P = .086) in intervention group practices after 4 feedback reports. When ignoring test repeatability, these differences between the groups were slightly more pronounced: OR = 2.4 (P = .033) after 3 and OR=2.2 (P = .051) after 4 feedback reports. CONCLUSIONS In the course of 1 year, we observed a small and late effect of e-learning and repeated feedback on the quality of spirometry as performed by family practice nurses. This intervention does not seem to compensate the lack of rigorous training and experience in performing spirometry tests in most practices. PMID:21747104

  3. Effect of e-learning and repeated performance feedback on spirometry test quality in family practice: a cluster trial.

    Science.gov (United States)

    Schermer, Tjard R; Akkermans, Reinier P; Crockett, Alan J; van Montfort, Marian; Grootens-Stekelenburg, Joke; Stout, Jim W; Pieters, Willem

    2011-01-01

    Spirometry has become an indispensable tool in primary care to exclude, diagnose, and monitor chronic respiratory conditions, but the quality of spirometry tests in family practices is a reason for concern. Aim of this study was to investigate whether a combination of e-learning and bimonthly performance feedback would improve spirometry test quality in family practices in the course of 1 year. Our study was a cluster trial with 19 family practices allocated to intervention or control conditions through minimization. Intervention consisted of e-learning and bimonthly feedback reports to practice nurses. Control practices received only the joint baseline workshop. Spirometry quality was assessed by independent lung function technicians. Two outcomes were defined, with the difference between rates of tests with 2 acceptable and repeatable blows being the primary outcome and the difference between rates of tests with 2 acceptable blows being the secondary outcome. We used multilevel logistic regression analysis to calculate odds ratios (ORs) for an adequate test in intervention group practices. We analyzed 1,135 tests. Rate of adequate tests was 33% in intervention and 30% in control group practices (OR = 1.3; P=.605). Adequacy of tests did not differ between groups but tended to increase with time: OR = 2.2 (P = .057) after 3 and OR = 2.0 (P = .086) in intervention group practices after 4 feedback reports. When ignoring test repeatability, these differences between the groups were slightly more pronounced: OR = 2.4 (P = .033) after 3 and OR=2.2 (P = .051) after 4 feedback reports. In the course of 1 year, we observed a small and late effect of e-learning and repeated feedback on the quality of spirometry as performed by family practice nurses. This intervention does not seem to compensate the lack of rigorous training and experience in performing spirometry tests in most practices.

  4. Effect of Mindfulness Based Stress Reduction on Quality of Life (SF-36) and Spirometry Parameters, in Chemically Pulmonary Injured Veterans.

    Science.gov (United States)

    Arefnasab, Zahra; Ghanei, Mostafa; Noorbala, Ahmad Ali; Alipour, Ahmad; Babamahmoodi, Farhang; Babamahmoodi, Abdolreza; Salehi, Maryam

    2013-09-01

    Studies have shown that Mindfulness Based Stress Reduction (MBSR) has positive effect on physical and psychological dimensions of chronic illnesses. In this study for the first time we examine the effect of this new technique on quality of life and pulmonary function in chemically pulmonary injured veterans who have chronic pulmonary problem, psychological problems and low quality of life. Forty male pulmonary injured veterans were randomly replaced in two groups with 20 participants (MBSR and control Wait List (WL)). Then MBSR group received 8-weekly sessions intervention. We evaluate quality of life (used SF-36 questionnaire) and Spirometry parameters two times; before and after intervention in two group. We used "mixed factorial analyses of variance" test for analyzing data in each dependent variables. Then if we have significant interactional effect, we used -paired- sample t-test" for comparing before and after intervention data of each group, and "Independent-Sample t-test" for comparing after intervention data of two groups. The MBSR compare to WL group improved SF-36 total score, (F (1, 38) =12.09, P=0.001), "Role limitations due to physical problems"(F(1,38)= 6.92, P=0.01), "Role limitations due to emotional problems"(F(1,38)= 7.75, P=0.008), "Social functioning"(F(1,38)= 9.89, P=0.003), "Mental health"(F(1,38)= 15.93, P=0), "Vitality"(F(1,38)= 40.03, P≤0.001), and "Pain"(F(1,38)= 27.60, P≤0.001). MBSR had no significant effect on "FEV1" (F (1, 38) = 0.03, P=0.85),"FVC" (F (1, 38) = 0.16, P=0.69) and "FEV1/FVC" (F (1, 38) = 2.21, P=0.14). MBSR can improve individual's quality of life but not lung function in chemically pulmonary injured veterans.

  5. Excess Sodium Tetraphenylborate and Intermediates Decomposition Studies

    International Nuclear Information System (INIS)

    Barnes, M.J.; Peterson, R.A.

    1998-04-01

    The stability of excess amounts of sodium tetraphenylborate (NaTPB) in the In-Tank Precipitation (ITP) facility depends on a number of variables. Concentration of palladium, initial benzene, and sodium ion as well as temperature provide the best opportunities for controlling the decomposition rate. This study examined the influence of these four variables on the reactivity of palladium-catalyzed sodium tetraphenylborate decomposition. Also, single effects tests investigated the reactivity of simulants with continuous stirring and nitrogen ventilation, with very high benzene concentrations, under washed sodium concentrations, with very high palladium concentrations, and with minimal quantities of excess NaTPB. These tests showed the following.The testing demonstrates that current facility configuration does not provide assured safety of operations relative to the hazards of benzene (in particular to maintain the tank headspace below 60 percent of the lower flammability limit (lfl) for benzene generation rates of greater than 7 mg/(L.h)) from possible accelerated reaction of excess NaTPB. Current maximal operating temperatures of 40 degrees C and the lack of protection against palladium entering Tank 48H provide insufficient protection against the onset of the reaction. Similarly, control of the amount of excess NaTPB, purification of the organic, or limiting the benzene content of the slurry (via stirring) and ionic strength of the waste mixture prove inadequate to assure safe operation

  6. Excess Sodium Tetraphenylborate and Intermediates Decomposition Studies

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, M.J. [Westinghouse Savannah River Company, AIKEN, SC (United States); Peterson , R.A.

    1998-04-01

    The stability of excess amounts of sodium tetraphenylborate (NaTPB) in the In-Tank Precipitation (ITP) facility depends on a number of variables. Concentration of palladium, initial benzene, and sodium ion as well as temperature provide the best opportunities for controlling the decomposition rate. This study examined the influence of these four variables on the reactivity of palladium-catalyzed sodium tetraphenylborate decomposition. Also, single effects tests investigated the reactivity of simulants with continuous stirring and nitrogen ventilation, with very high benzene concentrations, under washed sodium concentrations, with very high palladium concentrations, and with minimal quantities of excess NaTPB. These tests showed the following.The testing demonstrates that current facility configuration does not provide assured safety of operations relative to the hazards of benzene (in particular to maintain the tank headspace below 60 percent of the lower flammability limit (lfl) for benzene generation rates of greater than 7 mg/(L.h)) from possible accelerated reaction of excess NaTPB. Current maximal operating temperatures of 40 degrees C and the lack of protection against palladium entering Tank 48H provide insufficient protection against the onset of the reaction. Similarly, control of the amount of excess NaTPB, purification of the organic, or limiting the benzene content of the slurry (via stirring) and ionic strength of the waste mixture prove inadequate to assure safe operation.

  7. Studying allergic inflammation and spirometry over menstrual cycles in well-controlled asthmatic women: Changes in progesterone and estradiol affect neither FENO levels nor lung function.

    Science.gov (United States)

    Nittner-Marszalska, Marita; Dor-Wojnarowska, Anna; Wolańczyk-Mędrala, Anna; Rosner-Tenerowicz, Anna; Zimmer, Mariusz; Dobek, Julia; Gomułka, Krzysztof; Parużyńska, Anna; Panaszek, Bernard

    2018-05-01

    It has been reported that female sex hormones influence on allergic inflammation and ventilation parameters in asthma but conclusions drawn by different researchers are divergent. The aim of our study was to assess the impact of progesterone (Pg) and estradiol (E) on the dynamics of allergic inflammation and spirometry test results in regularly menstruating women with stable allergic asthma. 13 women (28 days menstrual cycle), aged 18-45, taking no hormonal contraceptives, with mild and moderate asthma, without reported exacerbations at the near-ovulation and/or menstruation time, were monitored during two consecutive menstrual cycles. They had 4 visits per cycle (the first day of menstruation was assumed to be day 1 of the cycle; visits were carried out on days: 3-4, 10-11, 13-14 and 23-24). At each visit asthma symptoms, asthma control test (ACT) results, asthma treatment, fractioned nitric oxide (FENO) levels, spirometry test results, Pg and E, levels were analyzed. As a result of the study, no essential variability in FENO values and ventilation parameters' values in the course of menstruation cycle were observed. Negative correlation between FENO values and Pg concentrations was demonstrated (r = 0.27), but no correlation between FENO values and E levels was shown. No relationship between the ACT values and ventilation parameters and the levels of the sex hormones under investigation was detected. We conclude that changing levels of estradiol and progesterone (regardless of the negative correlation of progesterone and FENO values) affect neither the dynamics of allergic inflammation nor pulmonary function in women with stable allergic mild/moderate asthma. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Spirometry, questionnaire and electronic medical record based COPD in a population survey: comparing prevalence, level of agreement and associations with potential risk factors.

    NARCIS (Netherlands)

    Borlée, F.; Yzermans, C.J.; Krop, E.; Rooijackers, J.; Aalders, B.; Zock, J.P.; Dijk, C.E. van; Maassen, C.B.M.; Schellevis, F.; Heederik, D.; Smit, L.A.M.

    2017-01-01

    Background: COPD-diagnosis is confirmed by post-bronchodilator (BD) spirometry. However, epidemiological studies often rely on pre-BD spirometry, self-reports, or medical records. This population-based study aims to determine COPD-prevalence based on four different operational definitions and their

  9. General practice variation in spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease in Denmark

    DEFF Research Database (Denmark)

    Koefoed, Mette M; Søndergaard, Jens; Christensen, René dePont

    2013-01-01

    Spirometry testing is essential to confirm an obstructive lung disease, but studies have reported that a large proportion of patients diagnosed with COPD or asthma have no history of spirometry testing. Also, it has been shown that many patients are prescribed medication for obstructive lung...... disease without a relevant diagnosis or spirometry test registered. General practice characteristics have been reported to influence diagnosis and management of several chronic diseases. However, these findings are inconsistent, and it is uncertain whether practice characteristics influence spirometry...... testing among patients receiving medication for obstructive lung disease. The aim of this study was therefore to examine if practice characteristics are associated with spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease....

  10. Analysis of spirometry results in hospitalized patients aged over 65 years

    Directory of Open Access Journals (Sweden)

    Wróblewska I

    2015-06-01

    Full Text Available Izabela Wróblewska,1 Piotr Oleśniewicz,2 Donata Kurpas,3 Mariusz Sołtysik,2 Jerzy Błaszczuk41Faculty of Health Science, Wroclaw Medical University, 2Institute of Tourism and Recreation, University School of Physical Education in Wroclaw, 3Department of Family Medicine, 4Faculty of Postgraduate Medical Training, Wroclaw Medical University, Wroclaw, Lower Silesia, PolandIntroduction and objective: The growing population of the elderly, as well as the occurrence of coexisting diseases and polypharmacy, is the reason why diseases of patients aged ≥65 years belong to the major issues of the contemporary medicine. Among the most frequent diseases of the elderly, there are respiratory system diseases. They are difficult to diagnose because of the patient group specificity, which is the reason for increased mortality among seniors, caused by underdiagnosis. The study objective was to assess the factors influencing spirometry results in hospitalized patients aged ≥65 years with respiratory system disorders.Material and methods: In the research, 217 (100% patients aged ≥65 years who underwent spirometry at the Regional Medical Center of the Jelenia Góra Valley Hospital in Poland were analyzed. In the statistical analysis, the STATISTICA 9.1 program, the t-test, the Shapiro–Wilk test, the ANOVA test, and the Scheffé’s test were applied.Results: The majority of the patients (59.4% were treated in the hospital. The most frequent diagnosis was malignant neoplasm (18%. The study showed a statistically significant dependence between the forced vital capacity (FVC, forced expiratory volume in 1 second (FEV1, and FEV1/FVC parameters and the time of hospitalization, as well as between the FVC and FEV1 parameters and the age of patients. The FVC parameter values turned out to be dependent on the main diagnosis. Highest results were noted in patients with the diagnosis of sleep apnea or benign neoplasm. A low FVC index can reflect restrictive

  11. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis.

    Science.gov (United States)

    de Vries, R; Brinkman, P; van der Schee, M P; Fens, N; Dijkers, E; Bootsma, S K; de Jongh, F H C; Sterk, P J

    2015-10-15

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We aimed to determine and optimize the technical performance and diagnostic accuracy of exhaled breath analysis linked to routine spirometry. Exhaled breath was collected in triplicate in healthy subjects by an eNose (SpiroNose) based on five identical metal oxide semiconductor sensor arrays (three arrays monitoring exhaled breath and two reference arrays monitoring ambient air) at the rear end of a pneumotachograph. First, the influence of flow, volume, humidity, temperature, environment, etc, was assessed. Secondly, a two-centre case-control study was performed using diagnostic and monitoring visits in day-to-day clinical care in patients with a (differential) diagnosis of asthma, chronic obstructive pulmonary disease (COPD) or lung cancer. Breathprint analysis involved signal processing, environment correction based on alveolar gradients and statistics based on principal component (PC) analysis, followed by discriminant analysis (Matlab2014/SPSS20). Expiratory flow showed a significant linear correlation with raw sensor deflections (R(2)  =  0.84) in 60 healthy subjects (age 43  ±  11 years). No correlation was found between sensor readings and exhaled volume, humidity and temperature. Exhaled data after environment correction were highly reproducible for each sensor array (Cohen's Kappa 0.81-0.94). Thirty-seven asthmatics (41  ±  14.2 years), 31 COPD patients (66  ±  8.4 years), 31 lung cancer patients (63  ±  10.8 years) and 45 healthy controls (41  ±  12.5 years) entered the cross-sectional study. SpiroNose could adequately distinguish between controls, asthma, COPD and lung cancer patients with cross-validation values

  12. [Spirometry interpretation feasibility among pre-school children according to the European Respiratory Society and American Thoracic Society Guidelines].

    Science.gov (United States)

    Donaire, Roberto M; González, Scarlett A; Moya, Ana I; Fierro, Laura T; Brockmann, Pablo V; Caussade, Solange L

    2015-01-01

    Spirometry is the most used test to evaluate pulmonary function. Guidelines that defined acceptability and repeatability criteria for its implementation and interpretation among preschoolers were published in 2007. Our objective was to quantify the actual compliance with these criteria among pre-school patients. A review was performed on the baseline spirometry measured in patients aged 2 to 5 years in the Pediatric Respiratory Laboratory of the Pontificia Universidad Católica de Chile, who were admitted due to recurrent or persistent coughing or wheezing. Only those results obtained in patients who took the test for the first time were considered. They were analyzed by international standards. A total of 93 spirometry results (mean age 57.4 ± 8.6 months, 48 males) were obtained, of which 44 (47%) met all acceptable criteria, 87 (93%) obtained expiratory time of ≥ 0.5seconds, and 67 (72%) of the patients had an end-expiratory flow of ≤10% from peak flow. The variation in the measurement of forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) was very low (intraclass correlation coefficient > 0.9). It was possible to meet the acceptability and repeatability criteria for spirometry among pre-school children in our Center, which was similar to previous reports. As in older children, this test is fully recommended for pre-school children who require lung function studies. Copyright © 2015. Publicado por Elsevier España, S.L.U.

  13. COPD case finding by spirometry in high-risk customers of urban community pharmacies: a pilot study.

    Science.gov (United States)

    Castillo, D; Guayta, R; Giner, J; Burgos, F; Capdevila, C; Soriano, J B; Barau, M; Casan, P

    2009-06-01

    COPD case finding is currently recommended at primary and tertiary care levels only. To evaluate the feasibility of a community pharmacy program for COPD case finding in high-risk customers by means of spirometry. Pilot cross-sectional descriptive study in 13 urban community pharmacies in Barcelona, Spain, from April to May 2007. Customers >40 years old with respiratory symptoms and/or a history of smoking were invited to participate in the study during pharmacists' routine work shifts. High-risk customers were identified by means of a 5-item COPD screening questionnaire based on criteria of the Global Initiative for Chronic Obstructive Lung Disease, and were invited to perform spirometry accordingly. Those with an FEV(1)/FVC ratio less than 0.70 were referred to the hospital for a repeat spirometry. Of the 161 pharmacy customers studied, 100 (62%) scored 3 or more items in the COPD screening questionnaire, and after spirometry, 21 (24%) had an FEV(1)/FVC ratiocustomers of urban community pharmacies is feasible. Similarly to primary care practitioners, pharmacists have access to high-risk, middle-aged subjects who have never been tested for COPD. Pharmacists can help with early detection of COPD if they are correctly trained.

  14. Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry.

    Science.gov (United States)

    Christensen, Gary E; Song, Joo Hyun; Lu, Wei; El Naqa, Issam; Low, Daniel A

    2007-06-01

    Breathing motion is one of the major limiting factors for reducing dose and irradiation of normal tissue for conventional conformal radiotherapy. This paper describes a relationship between tracking lung motion using spirometry data and image registration of consecutive CT image volumes collected from a multislice CT scanner over multiple breathing periods. Temporal CT sequences from 5 individuals were analyzed in this study. The couch was moved from 11 to 14 different positions to image the entire lung. At each couch position, 15 image volumes were collected over approximately 3 breathing periods. It is assumed that the expansion and contraction of lung tissue can be modeled as an elastic material. Furthermore, it is assumed that the deformation of the lung is small over one-fifth of a breathing period and therefore the motion of the lung can be adequately modeled using a small deformation linear elastic model. The small deformation inverse consistent linear elastic image registration algorithm is therefore well suited for this problem and was used to register consecutive image scans. The pointwise expansion and compression of lung tissue was measured by computing the Jacobian of the transformations used to register the images. The logarithm of the Jacobian was computed so that expansion and compression of the lung were scaled equally. The log-Jacobian was computed at each voxel in the volume to produce a map of the local expansion and compression of the lung during the breathing period. These log-Jacobian images demonstrate that the lung does not expand uniformly during the breathing period, but rather expands and contracts locally at different rates during inhalation and exhalation. The log-Jacobian numbers were averaged over a cross section of the lung to produce an estimate of the average expansion or compression from one time point to the next and compared to the air flow rate measured by spirometry. In four out of five individuals, the average log

  15. Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry

    International Nuclear Information System (INIS)

    Christensen, Gary E.; Song, Joo Hyun; Lu, Wei; Naqa, Issam El; Low, Daniel A.

    2007-01-01

    Breathing motion is one of the major limiting factors for reducing dose and irradiation of normal tissue for conventional conformal radiotherapy. This paper describes a relationship between tracking lung motion using spirometry data and image registration of consecutive CT image volumes collected from a multislice CT scanner over multiple breathing periods. Temporal CT sequences from 5 individuals were analyzed in this study. The couch was moved from 11 to 14 different positions to image the entire lung. At each couch position, 15 image volumes were collected over approximately 3 breathing periods. It is assumed that the expansion and contraction of lung tissue can be modeled as an elastic material. Furthermore, it is assumed that the deformation of the lung is small over one-fifth of a breathing period and therefore the motion of the lung can be adequately modeled using a small deformation linear elastic model. The small deformation inverse consistent linear elastic image registration algorithm is therefore well suited for this problem and was used to register consecutive image scans. The pointwise expansion and compression of lung tissue was measured by computing the Jacobian of the transformations used to register the images. The logarithm of the Jacobian was computed so that expansion and compression of the lung were scaled equally. The log-Jacobian was computed at each voxel in the volume to produce a map of the local expansion and compression of the lung during the breathing period. These log-Jacobian images demonstrate that the lung does not expand uniformly during the breathing period, but rather expands and contracts locally at different rates during inhalation and exhalation. The log-Jacobian numbers were averaged over a cross section of the lung to produce an estimate of the average expansion or compression from one time point to the next and compared to the air flow rate measured by spirometry. In four out of five individuals, the average log

  16. Age group classification and gender detection based on forced expiratory spirometry.

    Science.gov (United States)

    Cosgun, Sema; Ozbek, I Yucel

    2015-08-01

    This paper investigates the utility of forced expiratory spirometry (FES) test with efficient machine learning algorithms for the purpose of gender detection and age group classification. The proposed method has three main stages: feature extraction, training of the models and detection. In the first stage, some features are extracted from volume-time curve and expiratory flow-volume loop obtained from FES test. In the second stage, the probabilistic models for each gender and age group are constructed by training Gaussian mixture models (GMMs) and Support vector machine (SVM) algorithm. In the final stage, the gender (or age group) of test subject is estimated by using the trained GMM (or SVM) model. Experiments have been evaluated on a large database from 4571 subjects. The experimental results show that average correct classification rate performance of both GMM and SVM methods based on the FES test is more than 99.3 % and 96.8 % for gender and age group classification, respectively.

  17. Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry

    International Nuclear Information System (INIS)

    D'Souza, Warren D.; Kwok, Young; Deyoung, Chad; Zacharapoulos, Nicholas; Pepelea, Mark; Klahr, Paul; Yu, Cedric X.

    2005-01-01

    Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CT scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging

  18. Challenges in Collating Spirometry Reference Data for South-Asian Children: An Observational Study.

    Directory of Open Access Journals (Sweden)

    Sooky Lum

    Full Text Available Spirometry datasets from South-Asian children were collated from four centres in India and five within the UK. Records with transcription errors, missing values for height or spirometry, and implausible values were excluded(n = 110.Following exclusions, cross-sectional data were available from 8,124 children (56.3% male; 5-17 years. When compared with GLI-predicted values from White Europeans, forced expired volume in 1s (FEV1 and forced vital capacity (FVC in South-Asian children were on average 15% lower, ranging from 4-19% between centres. By contrast, proportional reductions in FEV1 and FVC within all but two datasets meant that the FEV1/FVC ratio remained independent of ethnicity. The 'GLI-Other' equation fitted data from North India reasonably well while 'GLI-Black' equations provided a better approximation for South-Asian data than the 'GLI-White' equation. However, marked discrepancies in the mean lung function z-scores between centres especially when examined according to socio-economic conditions precluded derivation of a single South-Asian GLI-adjustment.Until improved and more robust prediction equations can be derived, we recommend the use of 'GLI-Black' equations for interpreting most South-Asian data, although 'GLI-Other' may be more appropriate for North Indian data. Prospective data collection using standardised protocols to explore potential sources of variation due to socio-economic circumstances, secular changes in growth/predictors of lung function and ethnicities within the South-Asian classification are urgently required.

  19. Effect on attendance by including focused information on spirometry in preventive health checks: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Ørts, Lene Maria; Løkke, Anders; Bjerregaard, Anne-Louise; Maindal, Helle Terkildsen; Sandbæk, Annelli

    2016-12-01

    Early detection of lung diseases can help to reduce their severity. Lung diseases are among the most frequently occurring and serious diseases worldwide; nonetheless, many patients remain undiagnosed. Preventive health checks including spirometry can detect lung diseases at early stages; however, recruitment for health checks remains a challenge, and little is known about what motivates the attendance. The aim of the study is to examine whether focused information on spirometry in the invitation compared to general information will impact the attendance rate in preventive health checks. This randomized, controlled trial tests the effect of information on spirometry embedded in the Check your Health Preventive Program (CHPP). The CHPP is an open-label, household cluster-randomized, controlled trial offering a preventive health check to 30- to -49-year-olds in a Danish municipality from 2012 to 2017 (n = 26,216). During 2015-2016, 4356 citizens aged 30-49 years will be randomized into two groups. The intervention group receives an invitation which highlights the value and contents of spirometry as part of a health check and information about lung diseases. The comparison group receives a standard invitation containing practical information and specifies the contents of the general health check. Outcomes are (1) differences in attendance rates measured by the proportion of citizens attending each of the two study groups and (2) proportion of persons at risk defined by smoking status and self-reported lung symptoms in the study groups. The proportion of participants with abnormal spirometry assessed at the preventive health check will be compared between the two study groups. The results from the present study will inform future recruitment strategies to health checks. The developed material on content, value, and information about lung disease is feasible and transferable to other populations, making it easy to implement if effective. ClinicalTrials.gov: NCT

  20. Short- and long-term effectiveness of a supervised training program in spirometry use for primary care professionals.

    Science.gov (United States)

    Represas-Represas, Cristina; Botana-Rial, Maribel; Leiro-Fernández, Virginia; González-Silva, Ana Isabel; García-Martínez, Ana; Fernández-Villar, Alberto

    2013-09-01

    Despite the importance of spirometry, its use and quality are limited in the Primary Care setting. There are few accredited training programs that have demonstrated improvement in the quality of spirometric studies. In this paper, we analyze the short- and long-term effectiveness of a supervised training program for performing and interpreting spirometries. Ours is an intervention study with before and after measurements. The target population included teams of physicians and nursing staff at 26 health-care centers in the area of Vigo (Galicia, Spain). The structured training program involved 2 theoretical and practical training sessions (that were 2months apart), an intermediate period of 30 supervised spirometries performed in the respective centers and weekly e-mail exercises. Effectiveness was evaluated using exercises at the beginning (test 1) and the end (test 2) of the 1st day, 2nd day (test 3) and one year later (test 4), as well as the analysis of spirometries done in month1, month2 and one year later. Participants also completed a survey about their satisfaction. 74 participants initiated the program; 72 completed the program, but only 45 participated in the one-year evaluation. Mean test scores were: 4.1±1.9 on test 1; 7.5±1.6 on test 2; 8.9±1.3 on test 3, and 8.8±1.4 on test 4. During month1, the percentage of correctly done/interpreted tests was 71%, in month two it was 91% and after one year it was 83% (Ptraining program based on theoretical and practical workshops and a supervised follow-up of spirometries significantly improved the ability of Primary Care professionals to carry out and interpret spirometric testing, although the quality of the tests diminished over time. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.

  1. Does excessive pronation cause pain?

    DEFF Research Database (Denmark)

    Olesen, C G; Nielsen, Rasmus Gottschalk N; Rathleff, Michael Skovdal

    2008-01-01

    Excessive pronation could be an inborn abnormality or an acquired foot disorder caused by overuse, inadequate supported shoes or inadequate foot training. When the muscles and ligaments of the foot are insufficient it can cause an excessive pronation of the foot. The current treatment consist of ...

  2. Country Fundamentals and Currency Excess Returns

    Directory of Open Access Journals (Sweden)

    Daehwan Kim

    2014-06-01

    Full Text Available We examine whether country fundamentals help explain the cross-section of currency excess returns. For this purpose, we consider fundamental variables such as default risk, foreign exchange rate regime, capital control as well as interest rate in the multi-factor model framework. Our empirical results show that fundamental factors explain a large part of the cross-section of currency excess returns. The zero-intercept restriction of the factor model is not rejected for most currencies. They also reveal that our factor model with country fundamentals performs better than a factor model with usual investment-style factors. Our main empirical results are based on 2001-2010 balanced panel data of 19 major currencies. This paper may fill the gap between country fundamentals and practitioners' strategies on currency investment.

  3. Does Excessive Pronation Cause Pain?

    DEFF Research Database (Denmark)

    Mølgaard, Carsten Møller; Olesen Gammelgaard, Christian; Nielsen, R. G.

    Excessive pronation could be an inborn abnormality or an acquired foot disorder caused by overuse, inadequate supported shoes or inadequate foot training. When the muscles and ligaments of the foot are insufficient it can cause an excessive pronation of the foot. The current treatment consist...... of antipronation shoes or insoles, which latest was studied by Kulce DG., et al (2007). So far there have been no randomized controlled studies showing methods that the effect of this treatment has not been documented. Therefore the authors can measure the effect of treatments with insoles. Some of the excessive...

  4. Studies on the correlation between pre-and post-operative perfusion scintigraphy and differential spirometry in operated lungs

    International Nuclear Information System (INIS)

    Kaseda, Shizuka; Ikeda, Takaaki; Sakai, Tadaaki; Tomaru, Hiroko; Ishihara, Tsuneo; Kikuchi, Keiichi.

    1982-01-01

    For the purpose of clarifying the relationship between the percentage of perfusion and that of vital capacity or oxygen uptake on the affected lung, perfusion scintigraphy using sup(99m)Tc-MAA and differential spirometry were performed in twenty patients including sixteen patients with lung cancer. Both examinations were performed before and after the operation. The results are as follows: (1) There is a significant correlation between the percentage of perfusion and that of vital capacity or oxygen uptake of the affected lung before and after the operation. (2) The estimation of the percentage of vital capacity or oxygen uptake of the affected lung is possible by combining the spirometry and sup(99m)Tc-MAA pulmonary scintigraphy. (author)

  5. Correlation of single-breath count test and neck flexor muscle strength with spirometry in myasthenia gravis.

    Science.gov (United States)

    Elsheikh, Bakri; Arnold, W David; Gharibshahi, Shahram; Reynolds, Jerold; Freimer, Miriam; Kissel, John T

    2016-01-01

    Although formal spirometry is the gold standard for monitoring respiratory function in patients with myasthenia gravis (MG), such testing is often delayed or unavailable. There is a need for a simple bedside test that can accurately measure respiratory function. We conducted a prospective, cross-sectional, single-blind study in adults with acetylcholine receptor antibody positive MG. Participants performed the single breath count test (SBCT) and underwent manual muscle strength testing, and a respiratory therapist performed spirometry blinded to SBCT and strength results. Thirty-one patients, aged 57 ± 19 years participated. SBCT showed significant correlations with forced vital capacity (FVC), negative inspiratory force, and neck flexor strength (P strength (P = 0.02) but no correlation with shoulder abductor strength. These data suggest that the SBCT and neck flexor strength testing are valuable tools for bedside assessment of respiratory function in MG patients. © 2015 Wiley Periodicals, Inc.

  6. Inland excess water mapping using hyperspectral imagery

    Directory of Open Access Journals (Sweden)

    Csendes Bálint

    2016-01-01

    Full Text Available Hyperspectral imaging combined with the potentials of airborne scanning is a powerful tool to monitor environmental processes. The aim of this research was to use high resolution remotely sensed data to map the spatial extent of inland excess water patches in a Hungarian study area that is known for its oil and gas production facilities. Periodic floodings show high spatial and temporal variability, nevertheless, former studies have proven that the affected soil surfaces can be accurately identified. Besides separability measurements, we performed spectral angle classification, which gave a result of 85% overall accuracy and we also compared the generated land cover map with LIDAR elevation data.

  7. In vitro and in vivo evaluation of a new large animal spirometry device using mainstream CO2 flow sensors.

    Science.gov (United States)

    Ambrisko, T D; Lammer, V; Schramel, J P; Moens, Y P S

    2014-07-01

    A spirometry device equipped with mainstream CO2 flow sensor is not available for large animal anaesthesia. To measure the resistance of a new large animal spirometry device and assess its agreement with reference methods for volume measurements. In vitro experiment and crossover study using anaesthetised horses. A flow partitioning device (FPD) equipped with 4 human CO2 flow sensors was tested. Pressure differences were measured across the whole FPD and across each sensor separately using air flows (range: 90-720 l/min). One sensor was connected to a spirometry monitor for in vitro volume (3, 5 and 7 l) measurements. These measurements were compared with a reference method. Five anaesthetised horses were used for tidal volume (VT) measurements using the FPD and a horse-lite sensor (reference method). Bland-Altman analysis, ANOVA and linear regression analysis were used for data analysis. Pressure differences across each sensor were similar suggesting equal flow partitioning. The resistance of the device increased with flow (range: 0.3-1.5 cmH2 O s/l) and was higher than that of the horse-lite. The limits of agreement for volume measurements were within -1 and 2% in vitro and -12 and 0% in vivo. Nine of 147 VT measurements in horses were outside of the ± 10% limits of acceptance but most of these erroneous measurements occurred with VTs lower than 4 l. The determined correction factor for volume measurements was 3.97 ± 0.03. The limits of agreement for volume measurements by the new device were within ± 10% using clinically relevant range of volumes. The new spirometry device can be recommended for measurement of VT in adult Warmblood horses. © 2013 EVJ Ltd.

  8. Daily home-based spirometry during withdrawal of inhaled corticosteroid in severe to very severe chronic obstructive pulmonary disease.

    Science.gov (United States)

    Rodriguez-Roisin, Roberto; Tetzlaff, Kay; Watz, Henrik; Wouters, Emiel Fm; Disse, Bernd; Finnigan, Helen; Magnussen, Helgo; Calverley, Peter Ma

    2016-01-01

    The WISDOM study (NCT00975195) reported a change in lung function following withdrawal of fluticasone propionate in patients with severe to very severe COPD treated with tiotropium and salmeterol. However, little is known about the validity of home-based spirometry measurements of lung function in COPD. Therefore, as part of this study, following suitable training, patients recorded daily home-based spirometry measurements in addition to undergoing periodic in-clinic spirometric testing throughout the study duration. We subsequently determined the validity of home-based spirometry for detecting changes in lung function by comparing in-clinic and home-based forced expiratory volume in 1 second in patients who underwent stepwise fluticasone propionate withdrawal over 12 weeks versus patients remaining on fluticasone propionate for 52 weeks. Bland-Altman analysis of these data confirmed good agreement between in-clinic and home-based measurements, both across all visits and at the individual visits at study weeks 6, 12, 18, and 52. There was a measurable difference between the forced expiratory volume in 1 second values recorded at home and in the clinic (mean difference of -0.05 L), which may be due to suboptimal patient effort in performing unsupervised recordings. However, this difference remained consistent over time. Overall, these data demonstrate that home-based and in-clinic spirometric measurements were equally valid and reliable for assessing lung function in patients with COPD, and suggest that home-based spirometry may be a useful tool to facilitate analysis of changes in lung function on a day-to-day basis.

  9. INCENTIVE SPIROMETRY AND BREATHING EXERCISES WERE NOT ABLE TO IMPROVE RESTRICTIVE PULMONARY CHARACTERISTICS INDUCED BY WATER IMMERSION IN HEALTHY SUBJECTS

    OpenAIRE

    Aline A. Vepo,; Caroline S. Martinez; Giulia A. Wiggers; Franck M. Peçanha

    2016-01-01

    pulmonary volumes and capacities which could be at least in part similar to that happen in healthy individuals during water immersion. Objectives: To investigate if respiratory effects of water immersion are partially due to enhanced return venous from legs and arms and if physiotherapeutic techniques incentive spirometry (IS) and breathing exercises (BE) are able to improve pulmonary volumes and capacities in healthy subjects during water immersion. Design: Randomised, within-partici...

  10. Reference Values for Spirometry Derived Using Lambda, Mu, Sigma (LMS) Method in Korean Adults: in Comparison with Previous References.

    Science.gov (United States)

    Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul

    2018-01-15

    The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.

  11. Predictors of poor-quality spirometry in two cohorts of older adults in Russia and Belgium: a cross-sectional study.

    Science.gov (United States)

    Turkeshi, Eralda; Zelenukha, Dmitry; Vaes, Bert; Andreeva, Elena; Frolova, Elena; Degryse, Jean-Marie

    2015-07-23

    Spirometry is an important test for the diagnosis of respiratory diseases, yet it is underused especially in older adults. Several predictors of good-quality spirometry in this age group have been reported, based mainly on in/outpatients of geriatric and/or respiratory units. This study aims to assess predictors of poor-quality spirometry in community-dwelling older adults from two primary care cohorts in Russia and Belgium. Spirograms from two population-based cohort studies in Russia (CRYSTAL) and Belgium (BELFRAIL) were assessed in accordance with the American Thoracic Society/European Respiratory Society (ATS/ERS) acceptability and repeatability criteria and grouped into good and poor quality. Multivariable analysis assessed the association of poor-quality spirometry with socio-demographics, functional dependency, physical and mental functioning and co-morbidities. In all, 43.3% of the 522 BELFRAIL participants (84.71 ± 3.67 years old) and 57.7% of the 605 CRYSTAL participants (75.11 ± 5.97 years old) achieved all ATS/ERS acceptability and repeatability criteria. In both cohorts, those with poor-quality spirometry had lower cognitive function (mini-mental state examination (MMSE) ⩽ 24). After adjustment in multivariable analysis, MMSE ⩽ 24 had an odds ratio for poor-quality spirometry of 1.33 (95% CI = 0.78-2.28) in the BELFRAIL and 1.30 (95% CI = 0.88-1.91) in the CRYSTAL cohort. In community-dwelling older adults, including those over 80 years old, impaired cognition measured by the MMSE may not be an independent predictor of poor-quality spirometry. Further research is needed in this area, and spirometry should be used more often in older adults in primary care.

  12. Differences in spirometry values between U.S. children 6-11 years and adolescents 12-19 years with current asthma, 2007-2010.

    Science.gov (United States)

    Kit, Brian K; Simon, Alan E; Tilert, Timothy; Okelo, Sande; Akinbami, Lara J

    2016-03-01

    National Asthma Education and Prevention Program (NAEPP) guidelines recommend that periodic spirometry be performed in youth with asthma. NAEPP uses different spirometry criteria to define uncontrolled asthma for children (6-11 years) and adolescents (12+ years). To describe differences in spirometry between U.S. children and adolescents with current asthma. We examined cross-sectional spirometry data from 453 U.S. youth with current asthma age 6-19 years from the 2007-2010 National Health and Nutrition Examination Surveys. The main outcomes were percentage predicted forced expiratory volume at 1 sec (FEV1%) ≤80 and the ratio of FEV1 to forced vital capacity (FEV1/FVC) ≤0.80. We also examined the prevalence of youth with spirometry values consistent with uncontrolled asthma, using NAEPP age-specific criteria, defined for children aged 6-11 years as FEV1% ≤80 or FEV1/FVC ≤0.80, and for adolescents aged 12-19 years as FEV1% ≤80. Children 6-11 years and adolescents 12-19 years did not differ in prevalence of FEV1% ≤80 (10.1% vs. 9.0%) or FEV1/FVC ≤0.80 (30.6% vs. 29.8%). However, based on the NAEPP age-specific criteria, 33.0% of children 6-11 years and 9.0% of adolescents 12-19 years had spirometry values consistent with uncontrolled asthma (P spirometry values consistent with uncontrolled asthma did differ. The difference appears to stem mainly from the different spirometry criteria for the two age groups. © 2015 Wiley Periodicals, Inc.

  13. Assessment of five different guideline indication criteria for spirometry, including modified GOLD criteria, in order to detect COPD: data from 5,315 subjects in the PLATINO study.

    Science.gov (United States)

    Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R

    2014-10-30

    Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity.

  14. Limiting excessive postoperative blood transfusion after cardiac procedures. A review.

    OpenAIRE

    Ferraris, V A; Ferraris, S P

    1995-01-01

    Analysis of blood product use after cardiac operations reveals that a few patients ( 80%). The risk factors that predispose a minority of patients to excessive blood use include patient-related factors, transfusion practices, drug-related causes, and procedure-related factors. Multivariate studies suggest that patient age and red blood cell volume are independent patient-related variables that predict excessive blood product transfusion aft...

  15. Spirometry and volumetric capnography in lung function assessment of obese and normal-weight individuals without asthma.

    Science.gov (United States)

    Ferreira, Mariana S; Mendes, Roberto T; Marson, Fernando A L; Zambon, Mariana P; Antonio, Maria A R G M; Paschoal, Ilma A; Toro, Adyléia A D C; Severino, Silvana D; Ribeiro, Maria A G O; Ribeiro, José D

    To analyze and compare lung function of obese and healthy, normal-weight children and adolescents, without asthma, through spirometry and volumetric capnography. Cross-sectional study including 77 subjects (38 obese) aged 5-17 years. All subjects underwent spirometry and volumetric capnography. The evaluations were repeated in obese subjects after the use of a bronchodilator. At the spirometry assessment, obese individuals, when compared with the control group, showed lower values of forced expiratory volume in the first second by forced vital capacity (FEV 1 /FVC) and expiratory flows at 75% and between 25 and 75% of the FVC (p11 years (p<0.05). Even without the diagnosis of asthma by clinical criteria and without response to bronchodilator use, obese individuals showed lower FEV 1 /FVC values and forced expiratory flow, indicating the presence of an obstructive process. Volumetric capnography showed that obese individuals had higher alveolar tidal volume, with no alterations in ventilation homogeneity, suggesting flow alterations, without affecting lung volumes. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  16. An update on the LHC monojet excess

    Science.gov (United States)

    Asadi, Pouya; Buckley, Matthew R.; DiFranzo, Anthony; Monteux, Angelo; Shih, David

    2018-03-01

    In previous work, we identified an anomalous number of events in the LHC jets+MET searches characterized by low jet multiplicity and low-to-moderate transverse energy variables. Here, we update this analysis with results from a new ATLAS search in the monojet channel which also shows a consistent excess. As before, we find that this "monojet excess" is well-described by the resonant production of a heavy colored state decaying to a quark and a massive invisible particle. In the combined ATLAS and CMS data, we now find a local (global) preference of 3.3 σ (2.5 σ) for the new physics model over the Standard Model-only hypothesis. As the signal regions containing the excess are systematics-limited, we consider additional cuts to enhance the signal-to-background ratio. We show that binning finer in H T and requiring the jets to be more central can increase S/B by a factor of ˜1 .5.

  17. The development of a community-based spirometry service in the Canterbury region of New Zealand: observations on new service delivery.

    Science.gov (United States)

    Epton, Michael J; Stanton, Josh D; McGeoch, Graham R B; Shand, Brett I; Swanney, Maureen P

    2015-03-05

    In 2008, as part of the changes to develop integrated health care services in the Canterbury region of New Zealand, the local health board in collaboration with general practitioners, respiratory specialists and scientists introduced a programme for general practices to provide laboratory-quality spirometry in the community. The service adhered to the 2005 ATS/ERS international spirometry standards. The spirometry service was provided by trained practice nurses and community respiratory nurses, and was monitored and quality assured by certified respiratory scientists in the Respiratory Physiology Laboratory, Christchurch Hospital and CISO (Canterbury Initiative Services Organisation). These two organisations were responsible for organising training seminars and refresher courses on spirometry technique and interpretation of results. A total of 10 practices have now become approved spirometry providers, with the number of tests carried out in the primary care setting increasing gradually. Consistently high-quality spirometry tests have been obtained and are now presented on a centrally available results database for all hospital and community clinicians to review. Although the service has proved to be more convenient for patients, the tests have not been delivered as quickly as those carried out by the Respiratory Physiology Laboratory. However, the time scales for testing achieved by the community service is considered suitable for investigation of chronic disease. The success of the service has been dependent on several key factors including hospital and clinical support and a centralised quality assurance programme, a comprehensive training schedule and online clinical guidance and close integration between primary and secondary care clinicians.

  18. Assessment of serology and spirometry and the combination of both to complement microbiological isolation for earlier detection of Pseudomonas aeruginosa infection in children with cystic fibrosis.

    Science.gov (United States)

    Kotnik Pirš, Ana; Krivec, Uroš; Simčič, Saša; Seme, Katja

    2016-11-25

    The aim of this study was to assess whether serology and spirometry and the combination of both can complement culture-based detection for earlier recognition of Pseudomonas aeruginosa infection in children with cystic fibrosis. A 4 year longitudinal prospective study that included 67 Slovenian children with cystic fibrosis with a mean age of 10.5 years was conducted. Serology, spirometry and a scoring system combining serology and spirometry were assessed and compared. Infection was confirmed with isolation of Pseudomonas aeruginosa from respiratory samples. There was a significantly positive correlation between serology and the combination of serology and spirometry and Pseudomonas aeruginosa isolation (P spirometry and Pseudomonas aeruginosa isolation (P spirometry the highest sensitivity (0.90). Both had a high negative predictive value (0.93 and 0.79 respectively). Using serology and the combination of serology and lung function measurement can be beneficial for earlier detection of infection with Pseudomonas aeruginosa in children with cystic fibrosis when done simultaneously with standard culture-based detection from respiratory samples.

  19. Reference values for spirometry and their use in test interpretation: A Position Statement from the Australian and New Zealand Society of Respiratory Science.

    Science.gov (United States)

    Brazzale, Danny; Hall, Graham; Swanney, Maureen P

    2016-10-01

    Traditionally, spirometry testing tended to be confined to the realm of hospital-based laboratories but is now performed in a variety of health care settings. Regardless of the setting in which the test is conducted, the fundamental basis of spirometry is that the test is both performed and interpreted according to the international standards. The purpose of this Australian and New Zealand Society of Respiratory Science (ANZSRS) statement is to provide the background and recommendations for the interpretation of spirometry results in clinical practice. This includes the benchmarking of an individual's results to population reference data, as well as providing the platform for a statistically and conceptually based approach to the interpretation of spirometry results. Given the many limitations of older reference equations, it is imperative that the most up-to-date and relevant reference equations are used for test interpretation. Given this, the ANZSRS recommends the adoption of the Global Lung Function Initiative (GLI) 2012 spirometry reference values throughout Australia and New Zealand. The ANZSRS also recommends that interpretation of spirometry results is based on the lower limit of normal from the reference values and the use of Z-scores where available. © 2016 The Authors. Respirology published by John Wiley & Sons Australia, Ltd on behalf of Asian Pacific Society of Respirology.

  20. Analysis of the influence of respiratory disorders observed in preoperative spirometry on the dynamics of early inflammatory response in patients undergoing isolated coronary artery bypass grafting.

    Science.gov (United States)

    Szylińska, Aleksandra; Listewnik, Mariusz J; Rotter, Iwona; Rył, Aleksandra; Biskupski, Andrzej; Brykczyński, Mirosław

    2017-01-01

    Preoperative spirometry provides measurable information about the occurrence of respiratory disorders. The aim of this study was to assess the association between preoperative spirometry abnormalities and the intensification of early inflammatory responses in patients following coronary artery bypass graft in extracorporeal circulation. The study involved 810 patients (625 men and 185 women) aged 65.4±7.9 years who were awaiting isolated coronary artery bypass surgery. On the basis of spirometry performed on the day of admittance to the hospital, the patients were divided into three groups. Patients without respiratory problems constituted 78.8% of the entire group. Restricted breathing was revealed by spirometry in 14.9% and obstructive breathing in 6.3% of patients. Inter-group analysis showed statistically significant differences in C-reactive protein (CRP) between patients with restrictive spirometry abnormalities and patients without any pulmonary dysfunction. CRP concentrations differed before surgery ( P =0.006) and on the second ( P spirometry results from restrictive respiratory disorders have an elevated level of generalized inflammatory response both before and after the isolated coronary artery bypass surgery. Therefore, this group of patients should be given special postoperative monitoring and, in particular, intensive respiratory rehabilitation immediately after reconstitution.

  1. 24 CFR 236.60 - Excess Income.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Excess Income. 236.60 Section 236... § 236.60 Excess Income. (a) Definition. Excess Income consists of cash collected as rent from the... Rent. The unit-by-unit requirement necessitates that, if a unit has Excess Income, the Excess Income...

  2. Daily home-based spirometry during withdrawal of inhaled corticosteroid in severe to very severe chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Rodriguez-Roisin R

    2016-08-01

    Full Text Available Roberto Rodriguez-Roisin,1 Kay Tetzlaff,2,3 Henrik Watz,4 Emiel FM Wouters,5 Bernd Disse,2 Helen Finnigan,6 Helgo Magnussen,4 Peter MA Calverley7 1Respiratory Institute, Servei de Pneumologia, Hospital Clínic IDIBAPS-CIBERES, Universitat de Barcelona, Barcelona, Spain; 2Boehringer Ingelheim Pharma GmbH & Co. KG, Ingelheim, Germany; 3Department of Sports Medicine, University of Tübingen, Tübingen, Germany; 4Pulmonary Research Institute at Lung Clinic Grosshansdorf, Airway Research Center North, German Center for Lung Research, Grosshansdorf, Germany; 5Department of Respiratory Medicine, University Hospital Maastricht, Maastricht University, Maastricht, the Netherlands; 6Department of Biostatistics and Data Sciences, Boehringer Ingelheim, Bracknell, UK; 7Institute of Ageing and Chronic Disease, Aintree University Hospital, Liverpool, UK Abstract: The WISDOM study (NCT00975195 reported a change in lung function following withdrawal of fluticasone propionate in patients with severe to very severe COPD treated with tiotropium and salmeterol. However, little is known about the validity of home-based spirometry measurements of lung function in COPD. Therefore, as part of this study, following suitable training, patients recorded daily home-based spirometry measurements in addition to undergoing periodic in-clinic spirometric testing throughout the study duration. We subsequently determined the validity of home-based spirometry for detecting changes in lung function by comparing in-clinic and home-based forced expiratory volume in 1 second in patients who underwent stepwise fluticasone propionate withdrawal over 12 weeks versus patients remaining on fluticasone propionate for 52 weeks. Bland–Altman analysis of these data confirmed good agreement between in-clinic and home-based measurements, both across all visits and at the individual visits at study weeks 6, 12, 18, and 52. There was a measurable difference between the forced expiratory volume

  3. Excessive or unwanted hair in women

    Science.gov (United States)

    Hypertrichosis; Hirsutism; Hair - excessive (women); Excessive hair in women; Hair - women - excessive or unwanted ... Women normally produce low levels of male hormones (androgens). If your body makes too much of this ...

  4. Excessive masturbation after epilepsy surgery.

    Science.gov (United States)

    Ozmen, Mine; Erdogan, Ayten; Duvenci, Sirin; Ozyurt, Emin; Ozkara, Cigdem

    2004-02-01

    Sexual behavior changes as well as depression, anxiety, and organic mood/personality disorders have been reported in temporal lobe epilepsy (TLE) patients before and after epilepsy surgery. The authors describe a 14-year-old girl with symptoms of excessive masturbation in inappropriate places, social withdrawal, irritability, aggressive behavior, and crying spells after selective amygdalohippocampectomy for medically intractable TLE with hippocampal sclerosis. Since the family members felt extremely embarrassed, they were upset and angry with the patient which, in turn, increased her depressive symptoms. Both her excessive masturbation behavior and depressive symptoms remitted within 2 months of psychoeducative intervention and treatment with citalopram 20mg/day. Excessive masturbation is proposed to be related to the psychosocial changes due to seizure-free status after surgery as well as other possible mechanisms such as Kluver-Bucy syndrome features and neurophysiologic changes associated with the cessation of epileptic discharges. This case demonstrates that psychiatric problems and sexual changes encountered after epilepsy surgery are possibly multifactorial and in adolescence hypersexuality may be manifested as excessive masturbation behavior.

  5. Prediction of lung tumour position based on spirometry and on abdominal displacement: Accuracy and reproducibility

    International Nuclear Information System (INIS)

    Hoisak, Jeremy D.P.; Sixel, Katharina E.; Tirona, Romeo; Cheung, Patrick C.F.; Pignol, Jean-Philippe

    2006-01-01

    Background and purpose: A simulation investigating the accuracy and reproducibility of a tumour motion prediction model over clinical time frames is presented. The model is formed from surrogate and tumour motion measurements, and used to predict the future position of the tumour from surrogate measurements alone. Patients and methods: Data were acquired from five non-small cell lung cancer patients, on 3 days. Measurements of respiratory volume by spirometry and abdominal displacement by a real-time position tracking system were acquired simultaneously with X-ray fluoroscopy measurements of superior-inferior tumour displacement. A model of tumour motion was established and used to predict future tumour position, based on surrogate input data. The calculated position was compared against true tumour motion as seen on fluoroscopy. Three different imaging strategies, pre-treatment, pre-fraction and intrafractional imaging, were employed in establishing the fitting parameters of the prediction model. The impact of each imaging strategy upon accuracy and reproducibility was quantified. Results: When establishing the predictive model using pre-treatment imaging, four of five patients exhibited poor interfractional reproducibility for either surrogate in subsequent sessions. Simulating the formulation of the predictive model prior to each fraction resulted in improved interfractional reproducibility. The accuracy of the prediction model was only improved in one of five patients when intrafractional imaging was used. Conclusions: Employing a prediction model established from measurements acquired at planning resulted in localization errors. Pre-fractional imaging improved the accuracy and reproducibility of the prediction model. Intrafractional imaging was of less value, suggesting that the accuracy limit of a surrogate-based prediction model is reached with once-daily imaging

  6. Spirometry, questionnaire and electronic medical record based COPD in a population survey: Comparing prevalence, level of agreement and associations with potential risk factors.

    Science.gov (United States)

    Borlée, Floor; Yzermans, C Joris; Krop, Esmeralda; Aalders, Bernadette; Rooijackers, Jos; Zock, Jan-Paul; van Dijk, Christel E; Maassen, Catharina B M; Schellevis, François; Heederik, Dick; Smit, Lidwien A M

    2017-01-01

    COPD-diagnosis is confirmed by post-bronchodilator (BD) spirometry. However, epidemiological studies often rely on pre-BD spirometry, self-reports, or medical records. This population-based study aims to determine COPD-prevalence based on four different operational definitions and their level of agreement, and to compare associations between COPD-definitions and risk factors. COPD-prevalence in 1,793 adults from the general Dutch population (aged 18-70 years) was assessed based on self-reported data, Electronic Medical Records (EMR), and post-BD spirometry: using the FEV1/FVC below the lower limit of normal (LLN) and GOLD fixed cut-off (FEV1/FVC spirometry as a reference, sensitivity was calculated for self-reported and EMR-based COPD. Associations between COPD and known risk factors were assessed with logistic regression. Data were collected as part of the cross-sectional VGO study (Livestock Farming and Neighboring Residents' Health Study). The highest prevalence was found based on spirometry (GOLD: 10.9%, LLN: 5.9%), followed by self-report (4.6%) and EMR (2.9%). Self-reported or EMR-based COPD identified less than 30% of all COPD-cases based on spirometry. The direction of association between known risk factors and COPD was similar across the four definitions, however, magnitude and significance varied. Especially indicators of allergy were more strongly associated with self-reported COPD compared to the other definitions. COPD-prevalence varied depending on the used definition. A substantial number of subjects with spirometry-based COPD cannot be identified with questionnaires or medical records which can cause underestimation of COPD-prevalence. The influence of the different COPD-definitions on associations with known risk factors was limited.

  7. Effects of one-hour training course and spirometry on the ability of physicians to diagnose and treat chronic obstructive pulmonary disease.

    Science.gov (United States)

    Cai, Shan; Qin, Li; Tanoue, Lynn; Hu, Anmei; Jia, Xiujie; Luo, Hong; Chen, Yan; Chen, Ping; Peng, Hong

    2015-01-01

    In China, the prevalence of chronic obstructive pulmonary disease (COPD) in persons 40 years of age or older is estimated at 8.2%, but this is likely a substantial underestimate. Eight secondary hospitals which didn't have spirometries were chosen randomly in Hunan province of central south China. Physician subjects at these hospitals underwent a one-hour training course on the Chinese COPD guidelines. Physicians answered questionnaires assessing their knowledge of the guidelines before and after the training session. The mean correct scores of questionnaires were compared before and after training. Four out of the eight hospitals were given access to spirometry. Eligible patient subjects underwent spirometry testing prior to the physician visit. After seeing the patient, physicians were asked to answer a questionnaire relating to the diagnosis and severity of COPD. Physicians were then given the results of the spirometry, and asked to answer the same questionnaire. Physicians' responses before and after receiving the spirometry results were compared. 225 physicians participated in the training session. 207 questionnaires were completed. Mean scores (out of 100) before and after the training were 53.1 ± 21.7 and 93.3 ± 9.8, respectively. 18 physicians and 307 patient subjects participated in the spirometry intervention. Based on spirometric results, the prevalence of COPD was 38.8%. Physicians correctly identified the presence of COPD without spirometric data in 85 cases (76.6%); this increased to 117 cases (97.4%) once spirometric data were available. Without spirometric data, physicians incorrectly diagnosed COPD in 38 patients; this decreased to 6 patients once spirometric data were available. Spirometric data also improved the ability of physicians to correctly grade COPD severity. Simple educational training can substantially improve physicians' knowledge relating to COPD. Spirometry combined with education improves the ability of physicians to diagnose COPD

  8. Excess Early Mortality in Schizophrenia

    DEFF Research Database (Denmark)

    Laursen, Thomas Munk; Nordentoft, Merete; Mortensen, Preben Bo

    2014-01-01

    Schizophrenia is often referred to as one of the most severe mental disorders, primarily because of the very high mortality rates of those with the disorder. This article reviews the literature on excess early mortality in persons with schizophrenia and suggests reasons for the high mortality...... as well as possible ways to reduce it. Persons with schizophrenia have an exceptionally short life expectancy. High mortality is found in all age groups, resulting in a life expectancy of approximately 20 years below that of the general population. Evidence suggests that persons with schizophrenia may...... not have seen the same improvement in life expectancy as the general population during the past decades. Thus, the mortality gap not only persists but may actually have increased. The most urgent research agenda concerns primary candidates for modifiable risk factors contributing to this excess mortality...

  9. Severe rhabdomyolysis after excessive bodybuilding.

    Science.gov (United States)

    Finsterer, J; Zuntner, G; Fuchs, M; Weinberger, A

    2007-12-01

    A 46-year-old male subject performed excessive physical exertion during 4-6 h in a studio for body builders during 5 days. He was not practicing sport prior to this training and denied the use of any aiding substances. Despite muscle aching already after 1 day, he continued the exercises. After the last day, he recognized tiredness and cessation of urine production. Two days after discontinuation of the training, a Herpes simplex infection occurred. Because of acute renal failure, he required hemodialysis. There were absent tendon reflexes and creatine kinase (CK) values up to 208 274 U/L (normal: <170 U/L). After 2 weeks, CK had almost normalized and, after 4 weeks, hemodialysis was discontinued. Excessive muscle training may result in severe, hemodialysis-dependent rhabdomyolysis. Triggering factors may be prior low fitness level, viral infection, or subclinical metabolic myopathy.

  10. Verification of excess defense material

    International Nuclear Information System (INIS)

    Fearey, B.L.; Pilat, J.F.; Eccleston, G.W.; Nicholas, N.J.; Tape, J.W.

    1997-01-01

    The international community in the post-Cold War period has expressed an interest in the International Atomic Energy Agency (IAEA) using its expertise in support of the arms control and disarmament process in unprecedented ways. The pledges of the US and Russian presidents to place excess defense materials under some type of international inspections raises the prospect of using IAEA safeguards approaches for monitoring excess materials, which include both classified and unclassified materials. Although the IAEA has suggested the need to address inspections of both types of materials, the most troublesome and potentially difficult problems involve approaches to the inspection of classified materials. The key issue for placing classified nuclear components and materials under IAEA safeguards is the conflict between these traditional IAEA materials accounting procedures and the US classification laws and nonproliferation policy designed to prevent the disclosure of critical weapon-design information. Possible verification approaches to classified excess defense materials could be based on item accountancy, attributes measurements, and containment and surveillance. Such approaches are not wholly new; in fact, they are quite well established for certain unclassified materials. Such concepts may be applicable to classified items, but the precise approaches have yet to be identified, fully tested, or evaluated for technical and political feasibility, or for their possible acceptability in an international inspection regime. Substantial work remains in these areas. This paper examines many of the challenges presented by international inspections of classified materials

  11. Excess water dynamics in hydrotalcite: QENS study

    Indian Academy of Sciences (India)

    dynamics of excess water in hydrotalcite sample with varied content of excess water are reported. Translational motion of excess water can be best described by random transla- tional jump diffusion model. The observed increase in translational diffusivity with increase in the amount of excess water is attributed to the ...

  12. 34 CFR 300.16 - Excess costs.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Excess costs. 300.16 Section 300.16 Education... DISABILITIES General Definitions Used in This Part § 300.16 Excess costs. Excess costs means those costs that... for an example of how excess costs must be calculated.) (Authority: 20 U.S.C. 1401(8)) ...

  13. Asthma in pregnancy: association between the Asthma Control Test and the Global Initiative for Asthma classification and comparisons with spirometry.

    Science.gov (United States)

    de Araujo, Georgia Véras; Leite, Débora F B; Rizzo, José A; Sarinho, Emanuel S C

    2016-08-01

    The aim of this study was to identify a possible association between the assessment of clinical asthma control using the Asthma Control Test (ACT) and the Global Initiative for Asthma (GINA) classification and to perform comparisons with values of spirometry. Through this cross-sectional study, 103 pregnant women with asthma were assessed in the period from October 2010 to October 2013 in the asthma pregnancy clinic at the Clinical Hospital of the Federal University of Pernambuco. Questionnaires concerning the level of asthma control were administered using the Global Initiative for Asthma classification, the Asthma Control Test validated for asthmatic expectant mothers and spirometry; all three methods of assessing asthma control were performed during the same visit between the twenty-first and twenty-seventh weeks of pregnancy. There was a significant association between clinical asthma control assessment using the Asthma Control Test and the Global Initiative for Asthma classification (pspirometry. This study shows that both the Global Initiative for Asthma classification and the Asthma Control Test can be used for asthmatic expectant mothers to assess the clinical control of asthma, especially at the end of the second trimester, which is assumed to be the period of worsening asthma exacerbations during pregnancy. We highlight the importance of the Asthma Control Test as a subjective instrument with easy application, easy interpretation and good reproducibility that does not require spirometry to assess the level of asthma control and can be used in the primary care of asthmatic expectant mothers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Early warning and prevention of pneumonia in acute leukemia by patient education, spirometry, and positive expiratory pressure

    DEFF Research Database (Denmark)

    Møller, Tom; Moser, Claus; Adamsen, Lis

    2016-01-01

    Long-lasting neutropenia associated with acute myeloid leukemia (AML) and its treatment gives rise to a high risk of pneumonia. The use of broad-spectrum antibiotic prophylaxis during outpatient management has not completely protected patients against admission due to infections and neutropenic...... in their continuous daily measurement of FEV1 and use of PEP. Daily measures of FEV1 may be an important early warning tool for assessment of pulmonary deterioration during critical phases of neutropenia. We suggest that strategic patient education in the use of spirometry and PEP should be part of standard of care...

  15. The recent multi-ethnic global lung initiative 2012 (GLI2012) reference values don't reflect contemporary adult's North African spirometry.

    Science.gov (United States)

    Ben Saad, Helmi; El Attar, Mohamed Nour; Hadj Mabrouk, Khaoula; Ben Abdelaziz, Ahmed; Abdelghani, Ahmed; Bousarssar, Mohamed; Limam, Khélifa; Maatoug, Chiraz; Bouslah, Hmida; Charrada, Ameur; Rouatbi, Sonia

    2013-12-01

    The applicability of the recent multi-ethnic reference equations derived by the ERS Global Lung Initiative (ERS/GLI) in interpreting spirometry data in North African adult subjects has not been studied. To ascertain how well the recent ERS/GLI reference equations fit contemporary adult Tunisian spirometric data. Spirometric data were recorded from 1192 consecutive spirometry procedures in adults aged 18-60 years. Reference values and lower limits of normality (LLN) were calculated using the local and the ERS/GLI reference equations. Applied definitions: large airway obstructive ventilatory defect (LAOVD): FEV1/FVC contemporary Tunisian spirometry. Using Tunisian reference equations, 71.31%, 6.71% and 19.04% of spirometry records were interpreted as normal, and as having, LAOVD and TRVD, respectively. Using the ERS/GLI reference equations, these figures were respectively, 85.82%, 4.19% and 8.39%. The mean ± SD Z-scores for the contemporary healthy North African subject's data were -0.55 ± 0.87 for FEV1, -0.62 ± 0.86 for FVC and 0.10 ± 0.73 for FEV1/FVC. The present study don't recommend the use of the recent ERS/GLI reference equations to interpret spirometry in North African adult population. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Impulse oscillometry, spirometry, and passive smoking in healthy children and adolescents

    Directory of Open Access Journals (Sweden)

    C.I.S. Schivinski

    2017-11-01

    Conclusion: Children and adolescents exposed to PS had lower values for the spirometric variables and higher values for the oscillometric variables, indicating changes in forced and quiet parameters of lung function compared to the NPSG.

  17. Excess electron transport in cryoobjects

    International Nuclear Information System (INIS)

    Eshchenko, D.G.; Storchak, V.G.; Brewer, J.H.; Cottrell, S.P.; Cox, S.F.J.

    2003-01-01

    Experimental results on excess electron transport in solid and liquid phases of Ne, Ar, and solid N 2 -Ar mixture are presented and compared with those for He. Muon spin relaxation technique in frequently switching electric fields was used to study the phenomenon of delayed muonium formation: excess electrons liberated in the μ + ionization track converge upon the positive muons and form Mu (μ + e - ) atoms. This process is shown to be crucially dependent upon the electron's interaction with its environment (i.e., whether it occupies the conduction band or becomes localized in a bubble of tens of angstroms in radius) and upon its mobility in these states. The characteristic lengths involved are 10 -6 -10 -4 cm, the characteristic times range from nanoseconds to tens microseconds. Such a microscopic length scale sometimes enables the electron spend its entire free lifetime in a state which may not be detected by conventional macroscopic techniques. The electron transport processes are compared in: liquid and solid helium (where electron is localized in buble); liquid and solid neon (where electrons are delocalized in solid and the coexistence of localized and delocalized electrons states was found in liquid recently); liquid and solid argon (where electrons are delocalized in both phases); orientational glass systems (solid N 2 -Ar mixtures), where our results suggest that electrons are localized in orientational glass. This scaling from light to heavy rare gases enables us to reveal new features of excess electron localization on microscopic scale. Analysis of the experimental data makes it possible to formulate the following tendency of the muon end-of-track structure in condensed rare gases. The muon-self track interaction changes from the isolated pair (muon plus the nearest track electron) in helium to multi-pair (muon in the vicinity of tens track electrons and positive ions) in argon

  18. [The role of spirometry in encouraging smoking cessation in general practice. A pilot study using "lung age"].

    Science.gov (United States)

    Lorenzo, A; Noël, F; Lorenzo, M; Van Den Broucke, J

    2017-09-01

    Our aim was to investigate whether spirometry, performed in general practitioners' offices would change non-motivated smokers' attitudes toward smoking cessation. We performed an interventional, prospective, before-after single-center study, approved by a research ethics committee. We included 74 smokers older than 18years old, who reported no intention to quit smoking, whatever they were visiting general practitioners for. We performed spirometry and gave them their results, FEV 1 /FVC and lung age together with a comment on it. Nine months later, we called them for another assessment. Fifty-six percent were women with an average-age of 46.5, who smoked 26.3 pack-years. Eighty-two percent of them had normal FEV 1 /FVC but lung age was pathological among 38% of them. Nine months later, 61.1% reported an increased motivation to quit smoking. They smoked 10.9 cigarettes per day versus 13,3 at baseline (P=0.0254). Increase in motivation was not statistically related to age, gender, previous smoking cessations, daily smoking, nicotine dependence or an abnormal FEV 1 /VC ratio (P>0.75) but was significantly related to the presence of an abnormal lung age status (Pspirometry in general practice, combined with the determination of the lung age, may increase motivation towards smoking cessation in smokers who lack motivation. Copyright © 2016 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  19. Determination of functional residual capacity with 133-xenon radiospirometry. Comparison with body plethysmography and helium spirometry. Effect of body position

    International Nuclear Information System (INIS)

    Kauppinen-Walin, K.; Sovijaervi, A.R.A.; Muittari, A.; Uusitalo, A.

    1980-01-01

    The accuracy of 133-xenon radiospirometry for determination of FRC in healthy subjects was studied. Forty volunteers, both smokers and non-smokers, were examined. The FRC of each subject was concurrently determined with radiospirometric, He-dilution in closed circuit, and body plethysmographic methods. The mean FRC measured by radiospirometry (FRCsub(RS)) was 0.72 1 larger than that measured by helium spirometry (FRCsub(He)) in sitting position (P<0.01). In supine position the FRCsub(RS) was 0.65 1 larger than the FRCsub(He) (P<0.01). The body plethysmography (sitting position) gave FRC (TGV) 0.35 1 larger than the FRCsub(He) sitting (P<0.01). The FRCsub(He) and the FRCsub(RS) in the sitting position were 0.48 and 0.55 1 larger than in the supine position (P<0.01), respectively. Trapped air correlated significantly (P<0.01) with the difference FRCsub(RS) - FRCsub(He), when sitting. The results indicated that the FRC determined radiospirometrically is significantly larger than the FRC determined with He-spirometry. The difference is systematic, suggesting that it is caused by 133-xenon dissolved in blood and accumulated in tissues of the thoracic cage and by dissimilar representation of trapped air in FRCsub(RS) and FRCsub(He). After correction for systematic error, the FRC obtained as a by-product of radiospirometry may be used. (author)

  20. COPD Diagnostic Questionnaire (CDQ) for selecting at-risk patients for spirometry: a cross-sectional study in Australian general practice.

    Science.gov (United States)

    Stanley, Anthony J; Hasan, Iqbal; Crockett, Alan J; van Schayck, Onno C P; Zwar, Nicholas A

    2014-07-10

    Using the COPD Diagnostic Questionnaire (CDQ) as a selection tool for spirometry could potentially improve the efficiency and accuracy of chronic obstructive pulmonary disease (COPD) diagnosis in at-risk patients. To identify an optimal single cut point for the CDQ that divides primary care patients into low or high likelihood of COPD, with the latter group undergoing spirometry. Former or current smokers aged 40-85 years with no prior COPD diagnosis were invited to a case-finding appointment with the practice nurse at various general practices in Sydney, Australia. The CDQ was collected and pre- and post-bronchodilator spirometry was performed. Cases with complete CDQ data and spirometry meeting quality standards were analysed (1,054 out of 1,631 patients). CDQ cut points were selected from a receiver operating characteristic (ROC) curve. The area under the ROC curve was 0.713. A cut point of 19.5 had the optimal combination of sensitivity (63%) and specificity (70%) with two-thirds below this cut point. A cut point of 14.5 corresponded to a sensitivity of 91%, specificity of 35% and negative predictive value of 96%, and 31% of patients below this cut point. The CDQ can be used to select patients at risk of COPD for spirometry using one cut point. We consider two possible cut points. The 19.5 cut point excludes a higher proportion of patients from undergoing spirometry with the trade-off of more false negatives. The 14.5 cut point has a high sensitivity and negative predictive value, includes more potential COPD cases but has a higher rate of false positives.

  1. Prevalence of Airflow Limitation Defined by Pre- and Post-Bronchodilator Spirometry in a Community-Based Health Checkup: The Hisayama Study.

    Science.gov (United States)

    Fukuyama, Satoru; Matsumoto, Koichiro; Kaneko, Yasuko; Kan-o, Keiko; Noda, Naotaka; Tajiri-Asai, Yukari; Nakano, Takako; Ishii, Yumiko; Kiyohara, Yutaka; Nakanishi, Yoichi; Inoue, Hiromasa

    2016-02-01

    Spirometry in health checkup may contribute to early diagnosis of chronic obstructive pulmonary disease (COPD) and asthma. Although post-bronchodilator airflow limitation is essential for definite diagnosis of COPD and post-bronchodilator normalization of airflow is suggestive of asthma, this test has not been prevailed in health checkup. The objective of this study was to estimate the prevalence of airflow limitation defined by pre- and post-bronchodilator spirometry in health checkup. Post-bronchodilator spirometry was conducted for participants with airflow limitation in a town-wide health checkup for residents aged 40 years and older in Hisayama, a town in the western part of Japan. The prevalence of pre- and post-bronchodilator airway limitation defined by FEV1/FVC spirometry. In males, the age of current smokers was significantly younger than those of never smokers and former smokers. In females, the ages of current- and former smokers were significantly younger than never smokers. The values of %FEV1 and %FVC in current smokers were significantly lower than those in former smokers and never smokers. Two hundred sixty nine subjects, 85% of total subjects with a pre-bronchodilator FEV1/FVC spirometry. The prevalence of pre-bronchodilator airflow limitation was 14.6% in males and 13.7% in females, and the prevalence of post-bronchodilator airway limitation was 8.7% and 8.7%, respectively. Post-bronchodilator spirometry in health checkup would reduce the number of subjects with probable COPD to two-third. Recommendation for those examinees to take further evaluations may pave the way for early intervention.

  2. Excess electron transport in cryoobjects

    CERN Document Server

    Eshchenko, D G; Brewer, J H; Cottrell, S P; Cox, S F J

    2003-01-01

    Experimental results on excess electron transport in solid and liquid phases of Ne, Ar, and solid N sub 2 -Ar mixture are presented and compared with those for He. Muon spin relaxation technique in frequently switching electric fields was used to study the phenomenon of delayed muonium formation: excess electrons liberated in the mu sup + ionization track converge upon the positive muons and form Mu (mu sup + e sup -) atoms. This process is shown to be crucially dependent upon the electron's interaction with its environment (i.e., whether it occupies the conduction band or becomes localized in a bubble of tens of angstroms in radius) and upon its mobility in these states. The characteristic lengths involved are 10 sup - sup 6 -10 sup - sup 4 cm, the characteristic times range from nanoseconds to tens microseconds. Such a microscopic length scale sometimes enables the electron spend its entire free lifetime in a state which may not be detected by conventional macroscopic techniques. The electron transport proc...

  3. Viabilidade da realização de espirometria em pré-escolares Feasibility of spirometry in preschool children

    Directory of Open Access Journals (Sweden)

    Tiago Neves Veras

    2011-02-01

    Full Text Available OBJETIVO: Determinar a taxa de sucesso na obtenção de resultados adequados de espirometria em pacientes pré-escolares. MÉTODOS: Foram analisados os resultados de espirometrias de crianças menores que 6 anos. Todos os testes foram realizados no Laboratório de Função Pulmonar do Hospital Infantil Jeser Amarante Faria, em Joinville (SC entre junho de 2009 e fevereiro de 2010. O programa utilizado continha um incentivo de animação (bolhas de sabão.Os procedimentos foram realizados por um pneumologista infantil e obedeceram aos critérios de reprodutibilidade e aceitabilidade preconizados pela American Thoracic Society. Buscou-se atingir um tempo expiratório de pelo menos 1 s. Os seguintes parâmetros foram registrados: CVF, VEF0,5, VEF1 e relação VEF1/CVF. RESULTADOS: Nossa amostra consistiu de 74 crianças. A taxa de sucesso foi de 82%, com melhora no desempenho do teste em idades mais avançadas, mas sem significado estatístico (p > 0,05. Em média, foram necessárias 6,6 tentativas durante o exame para a obtenção de curvas aceitáveis e reprodutíveis. Todos os 61 testes bem sucedidos tiveram resultados de VEF0,5 e VEF1 satisfatórios. Através de escore Z, constatou-se que 21,6 % das crianças apresentavam com padrão obstrutivo. CONCLUSÕES: A taxa de sucesso da espirometria foi alta em nossa amostra, mostrando que esse é um método válido de avaliação da função pulmonar em pré-escolares. O uso de métodos de incentivo e a realização do teste por profissionais treinados no trabalho com crianças podem estar associados à elevada taxa de sucesso em nossa amostraOBJECTIVE: To determine the rate at which satisfactory spirometry results are obtained (spirometry success rate in preschool children. METHODS: We analyzed the spirometry results of children 0.05. An average of 6.6 attempts/test were needed in order to achieve acceptable, reproducible curves. All 61 successful tests produced satisfactory FEV0.5 and FEV1 values

  4. 34 CFR 668.166 - Excess cash.

    Science.gov (United States)

    2010-07-01

    ... the Secretary for the costs the Secretary incurred in providing that excess cash to the institution... 34 Education 3 2010-07-01 2010-07-01 false Excess cash. 668.166 Section 668.166 Education..., DEPARTMENT OF EDUCATION STUDENT ASSISTANCE GENERAL PROVISIONS Cash Management § 668.166 Excess cash. (a...

  5. 10 CFR 904.10 - Excess energy.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Excess energy. 904.10 Section 904.10 Energy DEPARTMENT OF ENERGY GENERAL REGULATIONS FOR THE CHARGES FOR THE SALE OF POWER FROM THE BOULDER CANYON PROJECT Power Marketing § 904.10 Excess energy. (a) If excess Energy is determined by the United States to be available...

  6. 7 CFR 985.56 - Excess oil.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Excess oil. 985.56 Section 985.56 Agriculture... HANDLING OF SPEARMINT OIL PRODUCED IN THE FAR WEST Order Regulating Handling Volume Limitations § 985.56 Excess oil. Oil of any class in excess of a producer's applicable annual allotment shall be identified as...

  7. Advantage of impulse oscillometry over spirometry to diagnose chronic obstructive pulmonary disease and monitor pulmonary responses to bronchodilators: An observational study

    Directory of Open Access Journals (Sweden)

    Constantine Saadeh

    2015-04-01

    Full Text Available Objectives: This retrospective study was a comparative analysis of sensitivity of impulse oscillometry and spirometry techniques for use in a mixed chronic obstructive pulmonary disease group for assessing disease severity and inhalation therapy. Methods: A total of 30 patients with mild-to-moderate chronic obstructive pulmonary disease were monitored by impulse oscillometry, followed by spirometry. Lung function was measured at baseline after bronchodilation and at follow-up (3–18 months. The impulse oscillometry parameters were resistance in the small and large airways at 5 Hz (R5, resistance in the large airways at 15 Hz (R15, and lung reactance (area under the curve X; AX. Results: After the bronchodilator therapy, forced expiratory volume in 1 second (FEV1 readings evaluated by spirometry were unaffected at baseline and at follow-up, while impulse oscillometry detected an immediate improvement in lung function, in terms of AX (p = 0.043. All impulse oscillometry parameters significantly improved at follow-up, with a decrease in AX by 37% (p = 0.0008, R5 by 20% (p = 0.0011, and R15 by 12% (p = 0.0097. Discussion: Impulse oscillometry parameters demonstrated greater sensitivity compared with spirometry for monitoring reversibility of airway obstruction and the effect of maintenance therapy. Impulse oscillometry may facilitate early treatment dose optimization and personalized medicine for chronic obstructive pulmonary disease patients.

  8. Phytoextraction of excess soil phosphorus

    International Nuclear Information System (INIS)

    Sharma, Nilesh C.; Starnes, Daniel L.; Sahi, Shivendra V.

    2007-01-01

    In the search for a suitable plant to be used in P phytoremediation, several species belonging to legume, vegetable and herb crops were grown in P-enriched soils, and screened for P accumulation potentials. A large variation in P concentrations of different plant species was observed. Some vegetable species such as cucumber (Cucumis sativus) and yellow squash (Cucurbita pepo var. melopepo) were identified as potential P accumulators with >1% (dry weight) P in their shoots. These plants also displayed a satisfactory biomass accumulation while growing on a high concentration of soil P. The elevated activities of phosphomonoesterase and phytase were observed when plants were grown in P-enriched soils, this possibly contributing to high P acquisition in these species. Sunflower plants also demonstrated an increased shoot P accumulation. This study shows that the phytoextraction of phosphorus can be effective using appropriate plant species. - Crop plants such as cucumber, squash and sunflower accumulate phosphorus and thus can be used in the phytoextraction of excess phosphorus from soils

  9. Phytoextraction of excess soil phosphorus

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Nilesh C. [Department of Biology, Western Kentucky University, 1906 College Heights Boulevard 11080, Bowling Green, KY 42101-1080 (United States); Starnes, Daniel L. [Department of Biology, Western Kentucky University, 1906 College Heights Boulevard 11080, Bowling Green, KY 42101-1080 (United States); Sahi, Shivendra V. [Department of Biology, Western Kentucky University, 1906 College Heights Boulevard 11080, Bowling Green, KY 42101-1080 (United States)]. E-mail: shiv.sahi@wku.edu

    2007-03-15

    In the search for a suitable plant to be used in P phytoremediation, several species belonging to legume, vegetable and herb crops were grown in P-enriched soils, and screened for P accumulation potentials. A large variation in P concentrations of different plant species was observed. Some vegetable species such as cucumber (Cucumis sativus) and yellow squash (Cucurbita pepo var. melopepo) were identified as potential P accumulators with >1% (dry weight) P in their shoots. These plants also displayed a satisfactory biomass accumulation while growing on a high concentration of soil P. The elevated activities of phosphomonoesterase and phytase were observed when plants were grown in P-enriched soils, this possibly contributing to high P acquisition in these species. Sunflower plants also demonstrated an increased shoot P accumulation. This study shows that the phytoextraction of phosphorus can be effective using appropriate plant species. - Crop plants such as cucumber, squash and sunflower accumulate phosphorus and thus can be used in the phytoextraction of excess phosphorus from soils.

  10. Angle β of greater than 80° at the start of spirometry may identify high-quality flow volume curves.

    Science.gov (United States)

    Lian, Ningfang; Li, Li; Ren, Weiying; Jiang, Zhilong; Zhu, Lei

    2017-04-01

    The American Thoracic Society (ATS) and European Respiratory Society (ERS) emphasize a satisfactory start in maximal expiratory flow-volume (MEFV) curves and highlight subjective parameters: performance without hesitation and expiration with maximum force. We described a new parameter, angle β for characterization of the start to the MEFV curve. Subjects completed the MEFV curve at least three times and at least two curves met ATS/ERS quality. Subjects were divided into normal, restrictive and obstructive groups according to pulmonary function test results. The tangent line was drawn at the start of the MEFV curve's ascending limb to the x-axis and the angle β between the tangent line and x-axis was obtained. The relationships between tangent of β, pulmonary function parameters (PFPs) and anthropometric data were assessed. The MEFV curves with insufficient explosion at the start were considered as poor-quality MEFV curves. In 998 subjects with high-quality spirometry, although PFP varied in relation to the three aspects: the angle β and its tangent were similar (P > 0.05), the tangent of β did not correlate with PFP or anthropometric measurements (P > 0.05) and the lower limit of normal (LLN) of the angle β was 80° in the group with high-quality spirometry (P < 0.05). Angle β derived from poor-quality MEFV curves was smaller than that from good quality one (P < 0.05). Angle β may function as a parameter to assess the expiratory efforts, which can be used to assess the quality of the MEFV curve start. © 2016 Asian Pacific Society of Respirology.

  11. Validation of Global Lung Function Initiative and All Ages Reference Equations for Forced Spirometry in Healthy Spanish Preschoolers.

    Science.gov (United States)

    Martín de Vicente, Carlos; de Mir Messa, Inés; Rovira Amigo, Sandra; Torrent Vernetta, Alba; Gartner, Silvia; Iglesias Serrano, Ignacio; Carrascosa Lezcano, Antonio; Moreno Galdó, Antonio

    2018-01-01

    Recent publication of multi-ethnic spirometry reference equations for subjects aged from 3-95 years aim to avoid age-related discontinuities and provide a worldwide standard for interpreting spirometric test results. To assess the agreement of the Global Lung Function Initiative (GLI-2012) and All ages (FEV 0.5 ) reference equations with the Spanish preschool lung function data. To verify the appropriateness of these reference values for clinical use in Spanish preschool children. Spirometric measurements were obtained from children aged 3 to 6 years attending 10 randomly selected schools in Barcelona (Spain). Stanojevic's quality control criteria were applied. Z-scores were calculated for the spirometry outcomes based on the GLI equations. If the z-score (mean) of each parameter was close to 0, with a maximum variance of ± 0.5 from the mean and a standard deviation of 1, the GLI-2012 equations would be applicable in our population. Of 543 children recruited, 405 (74.6%) were 'healthy', and of these, 380 were Caucasians. Of these 380, 81.6% (169 females, 141 males) performed technically acceptable and reproducible maneuvers to assess FEVt, and 69.5% achieved a clear end-expiratory plateau. Z-scores for FVC, FEV 1 , FEV 1 /FVC, FEV 0.75 , FEV 0.75 /FVC, FEV 0.5 , FEF 75 and FEF 25-75 all fell within ± 0.5, except for FEV 1 /FVC (0.53 z-scores). GLI equations are appropriate for Spanish preschool children. These data provide further evidence to support widespread application of the GLI reference equations. Copyright © 2017 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Echocardiography, spirometry, and systemic acute-phase inflammatory proteins in smokers with COPD or CHF: an observational study.

    Directory of Open Access Journals (Sweden)

    Bianca Beghé

    Full Text Available Chronic obstructive pulmonary disease (COPD and chronic heart failure (CHF may coexist in elderly patients with a history of smoking. Low-grade systemic inflammation induced by smoking may represent the link between these 2 conditions. In this study, we investigated left ventricular dysfunction in patients primarily diagnosed with COPD, and nonreversible airflow limitation in patients primarily diagnosed with CHF. The levels of circulating high-sensitive C-reactive protein (Hs-CRP, pentraxin 3 (PTX3, interleukin-1β (IL-1 β, and soluble type II receptor of IL-1 (sIL-1RII were also measured as markers of systemic inflammation in these 2 cohorts. Patients aged ≥ 50 years and with ≥ 10 pack years of cigarette smoking who presented with a diagnosis of stable COPD (n=70 or stable CHF (n=124 were recruited. All patients underwent echocardiography, N-terminal pro-hormone of brain natriuretic peptide measurements, and post-bronchodilator spirometry. Plasma levels of Hs-CRP, PTX3, IL-1 β, and sIL-1RII were determined by using a sandwich enzyme-linked immuno-sorbent assay in all patients and in 24 healthy smokers (control subjects. Although we were unable to find a single COPD patient with left ventricular dysfunction, we found nonreversible airflow limitation in 34% of patients with CHF. On the other hand, COPD patients had higher plasma levels of Hs-CRP, IL1 β, and sIL-1RII compared with CHF patients and control subjects (p < 0.05. None of the inflammatory biomarkers was different between CHF patients and control subjects. In conclusion, although the COPD patients had no evidence of CHF, up to one third of patients with CHF had airflow limitation, suggesting that routine spirometry is warranted in patients with CHF, whereas echocardiography is not required in well characterized patients with COPD. Only smokers with COPD seem to have evidence of systemic inflammation.

  13. Hyperpolarized {sup 3}helium magnetic resonance ventilation imaging of the lung in cystic fibrosis: comparison with high resolution CT and spirometry

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, Colm J.; Dodd, Jonathan D.; Skehan, Stephen J.; Masterson, James B. [St. Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); Hill, Catherine; Woodhouse, Neil; Wild, Jim M.; Fichele, Stan [Royal Hallamshire Hospital, The Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Gallagher, Charles G. [St. Vincent' s University Hospital, Department of National Referral Centre for Adult Cystic Fibrosis, Dublin (Ireland); Beek, Edwin J.R. van [Royal Hallamshire Hospital, The Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, IA (United States)

    2006-11-15

    The purpose of this study was to compare hyperpolarized {sup 3}helium magnetic resonance imaging ({sup 3}He MRI) of the lungs in adults with cystic fibrosis (CF) with high-resolution computed tomography (HRCT) and spirometry. Eight patients with stable CF prospectively underwent {sup 3}He MRI, HRCT, and spirometry within 1 week. Three-dimensional (3D) gradient-echo sequence was used during an 18-s breath-hold following inhalation of hyperpolarized {sup 3}He. Each lung was divided into six zones; {sup 3}He MRI was scored as percentage ventilation per lung zone. HRCT was scored using a modified Bhalla scoring system. Univariate (Spearman rank) and multivariate correlations were performed between {sup 3}He MRI, HRCT, and spirometry. Results are expressed as mean{+-}SD (range). Spirometry is expressed as percent predicted. There were four men and four women, mean age=31.9{+-}9 (20-46). Mean forced expiratory volume in 1 s (FEV){sub 1}=52%{+-}29 (27-93). Mean {sup 3}He MRI score=74%{+-}25 (55-100). Mean HRCT score=48.8{+-}24 (13.5-83). The correlation between {sup 3}He MRI and HRCT was strong (R={+-}0.89, p<0.001). Bronchiectasis was the only independent predictor of {sup 3}He MRI; {sup 3}He MRI correlated better with FEV{sub 1} and forced vital capacity (FVC) (R=0.86 and 0.93, p<0.01, respectively) than HRCT (R={+-}0.72 and {+-}0.81, p<0.05, respectively). This study showed that {sup 3}He MRI correlates strongly with structural HRCT abnormalities and is a stronger correlate of spirometry than HRCT in CF. (orig.)

  14. Effect of volume-oriented versus flow-oriented incentive spirometry on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly.

    Science.gov (United States)

    Lunardi, Adriana C; Porras, Desiderio C; Barbosa, Renata Cc; Paisani, Denise M; Marques da Silva, Cibele C B; Tanaka, Clarice; Carvalho, Celso R F

    2014-03-01

    Aging causes physiological and functional changes that impair pulmonary function. Incentive spirometry is widely used for lung expansion, but the effects of volume-oriented incentive spirometry (VIS) versus flow-oriented incentive spirometry (FIS) on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly are poorly understood. We compared VIS and FIS in elderly subjects and healthy adult subjects. Sixteen elderly subjects (9 women, mean ± SD age 70.6 ± 3.9 y, mean ± SD body mass index 23.8 ± 2.5 kg/m(2)) and 16 healthy adults (8 women, mean ± age 25.9 ± 4.3 y, mean ± body mass index 23.6 ± 2.4 kg/m(2)) performed quiet breathing, VIS, and FIS in randomized sequence. Chest wall kinematics (via optoelectronic plethysmography) and inspiratory muscle activity (via surface electromyography) were assessed simultaneously. Synchrony between the superior thorax and abdominal motion was calculated (phase angle). In the elderly subjects both types of incentive spirometry increased chest wall volumes similarly, whereas in the healthy adult subjects VIS increased the chest wall volume more than did FIS. FIS and VIS triggered similar lower thoracoabdominal synchrony in the elderly subjects, whereas in the healthy adults FIS induced lower synchrony than did VIS. FIS required more muscle activity in the elderly subjects to create an increase in chest wall volume. Incentive spirometry performance is influenced by age, and the differences between elderly and healthy adults response should be considered in clinical practice.

  15. Androgen excess: Investigations and management.

    Science.gov (United States)

    Lizneva, Daria; Gavrilova-Jordan, Larisa; Walker, Walidah; Azziz, Ricardo

    2016-11-01

    Androgen excess (AE) is a key feature of polycystic ovary syndrome (PCOS) and results in, or contributes to, the clinical phenotype of these patients. Although AE will contribute to the ovulatory and menstrual dysfunction of these patients, the most recognizable sign of AE includes hirsutism, acne, and androgenic alopecia or female pattern hair loss (FPHL). Evaluation includes not only scoring facial and body terminal hair growth using the modified Ferriman-Gallwey method but also recording and possibly scoring acne and alopecia. Moreover, assessment of biochemical hyperandrogenism is necessary, particularly in patients with unclear or absent hirsutism, and will include assessing total and free testosterone (T), and possibly dehydroepiandrosterone sulfate (DHEAS) and androstenedione, although these latter contribute limitedly to the diagnosis. Assessment of T requires use of the highest quality assays available, generally radioimmunoassays with extraction and chromatography or mass spectrometry preceded by liquid or gas chromatography. Management of clinical hyperandrogenism involves primarily either androgen suppression, with a hormonal combination contraceptive, or androgen blockade, as with an androgen receptor blocker or a 5α-reductase inhibitor, or a combination of the two. Medical treatment should be combined with cosmetic treatment including topical eflornithine hydrochloride and short-term (shaving, chemical depilation, plucking, threading, waxing, and bleaching) and long-term (electrolysis, laser therapy, and intense pulse light therapy) cosmetic treatments. Generally, acne responds to therapy relatively rapidly, whereas hirsutism is slower to respond, with improvements observed as early as 3 months, but routinely only after 6 or 8 months of therapy. Finally, FPHL is the slowest to respond to therapy, if it will at all, and it may take 12 to 18 months of therapy for an observable response. Copyright © 2016. Published by Elsevier Ltd.

  16. What controls deuterium excess in global precipitation?

    Directory of Open Access Journals (Sweden)

    S. Pfahl

    2014-04-01

    Full Text Available The deuterium excess (d of precipitation is widely used in the reconstruction of past climatic changes from ice cores. However, its most common interpretation as moisture source temperature cannot directly be inferred from present-day water isotope observations. Here, we use a new empirical relation between d and near-surface relative humidity (RH together with reanalysis data to globally predict d of surface evaporation from the ocean. The very good quantitative agreement of the predicted hemispherically averaged seasonal cycle with observed d in precipitation indicates that moisture source relative humidity, and not sea surface temperature, is the main driver of d variability on seasonal timescales. Furthermore, we review arguments for an interpretation of long-term palaeoclimatic d changes in terms of moisture source temperature, and we conclude that there remains no sufficient evidence that would justify to neglect the influence of RH on such palaeoclimatic d variations. Hence, we suggest that either the interpretation of d variations in palaeorecords should be adapted to reflect climatic influences on RH during evaporation, in particular atmospheric circulation changes, or new arguments for an interpretation in terms of moisture source temperature will have to be provided based on future research.

  17. Excess cash holdings and shareholder value

    OpenAIRE

    Lee, Edward; Powell, Ronan

    2011-01-01

    We examine the determinants of corporate cash holdings in Australia and the impact on shareholder wealth of holding excess cash. Our results show that a trade-off model best explains the level of a firm’s cash holdings in Australia. We find that 'transitory' excess cash firms earn significantly higher risk-adjusted returns compared to 'persistent' excess cash firms, suggesting that the market penalises firms that hoard cash. The marginal value of cash also declines with larger cash balances, ...

  18. Syndromes associated with nutritional deficiency and excess.

    Science.gov (United States)

    Jen, Melinda; Yan, Albert C

    2010-01-01

    Normal functioning of the human body requires a balance between nutritional intake and metabolism, and imbalances manifest as nutritional deficiencies or excess. Nutritional deficiency states are associated with social factors (war, poverty, famine, and food fads), medical illnesses with malabsorption (such as Crohn disease, cystic fibrosis, and after bariatric surgery), psychiatric illnesses (eating disorders, autism, alcoholism), and medications. Nutritional excess states result from inadvertent or intentional excessive intake. Cutaneous manifestations of nutritional imbalance can herald other systemic manifestations. This contribution discusses nutritional deficiency and excess syndromes with cutaneous manifestations of particular interest to clinical dermatologists. Copyright © 2010. Published by Elsevier Inc.

  19. Valor de la espirometría para el diagnostico de restricción pulmonar Accuracy of spirometry in the diagnosis of pulmonary restriction

    Directory of Open Access Journals (Sweden)

    Silvia Quadrelli

    2007-12-01

    Full Text Available Un defecto ventilatorio restrictivo está caracterizado por una reducción en la capacidad pulmonar total. El objetivo de este estudio fue evaluar la utilidad de la espirometría para determinar la presencia de restricción en pacientes con y sin obstrucción bronquial. Fueron incluídos 520 pacientes. Se definieron los valores normales mediante el intervalo de confianza del 95% (IC utilizando la ecuación de Morris para la espirometría, y la de la European Respiratory Society (ERS para capacidad pulmonar. Las espirometrías fueron clasificadas como obstructivas cuando mostraban relación volumen espiratorio forzado en 1 segundo (VEF1/capacidad vital forzada (CVF A restrictive ventilatory defect is characterized by a decreased total lung capacity (TLC. The objective of this study was to determine the accuracy of spirometry to detect pulmonary restriction in patients with or without airflow obstruction in the spirometry. Five hundred and twenty patients were included. Normal values for lung function were determined by using the 95% confidence interval (CI with Morris reference equation for spirometry and European Respiratory Society equation for lung volume. Spirometries were considered obstructive when FEV1/FVC ratio was <70% and FEV1 was below 95%CI. In patients without obstruction in the spirometry (n = 357 sensitivity and specificity were 42.2% and 94.3% respectively, negative predictive value (NPP was 86.6% and positive PV (PPV was 65.2%. In patients with an obstructive spirometry (n = 66 sensitivity increased to 75.8% but specificity decreased to 65.9%. PPV was only 57.8% and NPV 81.5%. Patients showing obstruction in the spirometry and false positives of a low FVC (n = 22 had similar values of FVC (57.36 ± 13.45 vs. 58.82 ± 8.71%, p = 0.6451, FEV1 (44.73 ± 19.24 vs. 44.0 ± 13.08%, p = 0.8745 and DLCO (67.50 ±27.23 vs. 77.00 ±16.00%, p = 0.1299 than true positives. Residual volume (RV (125.72 ± 64. vs. 77.96 ± 29.98%, p = 0

  20. Comparison of Flow and Volume Incentive Spirometry on Pulmonary Function and Exercise Tolerance in Open Abdominal Surgery: A Randomized Clinical Trial

    Science.gov (United States)

    Kumar, Amaravadi Sampath; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan

    2016-01-01

    Introduction Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. Aim To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. Materials and Methods A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni’s ‘t’-test. Exercise tolerance was analysed by Paired ‘T’-test. Results Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1st, 2nd and 3rd postoperative day when compared with preoperative day. On 4th and 5th postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group

  1. Bladder calculus presenting as excessive masturbation.

    Science.gov (United States)

    De Alwis, A C D; Senaratne, A M R D; De Silva, S M P D; Rodrigo, V S D

    2006-09-01

    Masturbation in childhood is a normal behaviour which most commonly begins at 2 months of age, and peaks at 4 years and in adolescence. However excessive masturbation causes anxiety in parents. We describe a boy with a bladder calculus presenting as excessive masturbation.

  2. Measuring excess capital capacity in agricultural production

    NARCIS (Netherlands)

    Zhengfei, G.; Kumbhakar, S.C.; Myers, R.J.; Oude Lansink, A.G.J.M.

    2009-01-01

    We introduce the concept "excess capital capacity" and employ a stochastic input requirement frontier to measure excess capital capacity in agricultural production. We also propose a two-step estimation method that allows endogenous regressors in stochastic frontier models. The first step uses

  3. The excessively crying infant : etiology and treatment

    NARCIS (Netherlands)

    Akhnikh, S.; Engelberts, A.C.; Sleuwen, B.E. van; Hoir, M.P. L’; Benninga, M.A.

    2014-01-01

    Excessive crying, often described as infantile colic, is the cause of 10% to 20% of all early pediatrician visits of infants aged 2 weeks to 3 months. Although usually benign and selflimiting, excessive crying is associated with parental exhaustion and stress. However, and underlying organic cause

  4. Part B Excess Cost Quick Reference Document

    Science.gov (United States)

    Ball, Wayne; Beridon, Virginia; Hamre, Kent; Morse, Amanda

    2011-01-01

    This Quick Reference Document has been prepared by the Regional Resource Center Program ARRA/Fiscal Priority Team to aid RRCP State Liaisons and other (Technical Assistance) TA providers in understanding the general context of state questions surrounding excess cost. As a "first-stop" for TA providers in investigating excess cost…

  5. Decommissioning of excess nuclear facilities

    International Nuclear Information System (INIS)

    Dickson, H.W.; Jacobs, D.J.; Auxier, J.A.

    1978-01-01

    The Department of Energy (DOE) is reviewing the radiological status of over 100 sites previously utilized by the Manhattan Engineering District (MED) and/or the Atomic Energy Commission (AEC) for handling uranium and thorium ores. Many of these sites have been returned to the control of private industry or to public use. Recent radiological surveys indicate that radiation levels at some of the sites exceed certain existing radiological health guidelines, some requiring remedial action. To assess the need for remedial action and to arrive at radiation levels acceptable for unrestricted use of these sites in the future, provisional radiological criteria for decontamination and decommissioning of property contaminated with radium have been developed. These criteria give due consideration to the level of risk, to consistency with existing guidelines, to achievability, enforceability, variability of natural background, flexibility in their application, and the achievement of levels as low as reasonably achievable. Based upon analyses of exposure pathways, numerical criteria have been derived for external gamma radiation, radon daughters levels in structures, radium concentrations in soil and surface contamination levels. In addition, a monitoring program has been designed to evaluate compliance with these decommissioning criteria. (author)

  6. Implication of zinc excess on soil health.

    Science.gov (United States)

    Wyszkowska, Jadwiga; Boros-Lajszner, Edyta; Borowik, Agata; Baćmaga, Małgorzata; Kucharski, Jan; Tomkiel, Monika

    2016-01-01

    This study was undertaken to evaluate zinc's influence on the resistance of organotrophic bacteria, actinomyces, fungi, dehydrogenases, catalase and urease. The experiment was conducted in a greenhouse of the University of Warmia and Mazury (UWM) in Olsztyn, Poland. Plastic pots were filled with 3 kg of sandy loam with pHKCl - 7.0 each. The experimental variables were: zinc applied to soil at six doses: 100, 300, 600, 1,200, 2,400 and 4,800 mg of Zn(2+) kg(-1) in the form of ZnCl2 (zinc chloride), and species of plant: oat (Avena sativa L.) cv. Chwat and white mustard (Sinapis alba) cv. Rota. Soil without the addition of zinc served as the control. During the growing season, soil samples were subjected to microbiological analyses on experimental days 25 and 50 to determine the abundance of organotrophic bacteria, actinomyces and fungi, and the activity of dehydrogenases, catalase and urease, which provided a basis for determining the soil resistance index (RS). The physicochemical properties of soil were determined after harvest. The results of this study indicate that excessive concentrations of zinc have an adverse impact on microbial growth and the activity of soil enzymes. The resistance of organotrophic bacteria, actinomyces, fungi, dehydrogenases, catalase and urease decreased with an increase in the degree of soil contamination with zinc. Dehydrogenases were most sensitive and urease was least sensitive to soil contamination with zinc. Zinc also exerted an adverse influence on the physicochemical properties of soil and plant development. The growth of oat and white mustard plants was almost completely inhibited in response to the highest zinc doses of 2,400 and 4,800 mg Zn(2+) kg(-1).

  7. 75 FR 27572 - Monthly Report of Excess Income and Annual Report of Uses of Excess Income

    Science.gov (United States)

    2010-05-17

    ... Income and Annual Report of Uses of Excess Income AGENCY: Office of the Chief Information Officer, HUD... permitted to retain Excess Income for projects under terms and conditions established by HUD. Owners must request to retain some or all of their Excess Income. The request must be submitted through http://www.pay...

  8. Clinical Utility of Additional Measurement of Total Lung Capacity in Diagnosing Obstructive Lung Disease in Subjects With Restrictive Pattern of Spirometry.

    Science.gov (United States)

    Lee, Hyun; Chang, Boksoon; Kim, Kyunga; Song, Won Jun; Chon, Hae Ri; Kang, Hyung Koo; Kim, Jung Soo; Jeong, Byeong-Ho; Oh, Yeon-Mok; Koh, Won-Jung; Park, Hye Yun

    2016-04-01

    Total lung capacity (TLC), forced expiratory flow between 25 and 75% (FEF25-75%), peak expiratory flow (PEF), or post-bronchodilator volume response is recommended to detect obstructive abnormalities in the lung. The present study was performed to evaluate the usefulness of these pulmonary function test (PFT) parameters to diagnose obstructive lung disease in subjects with a restrictive pattern of spirometry. A retrospective study was conducted in 64 subjects with a restrictive pattern of spirometry (normal FEV1/FVC and low FVC) out of 3,030 patients who underwent all pre- and post-bronchodilator spirometry and lung volume measurement between April 2008 and December 2010. After subjects were clinically classified into those with obstructive lung disease, restrictive lung disease, and mixed lung disease, the agreements between the clinical diagnosis and PFT classification according to TLC, FEF(25-75%), PEF, and post-bronchodilator response criteria were compared. Of 64 subjects, 18 (28.1%) were classified with obstructive lung disease, 39 (60.9%) had restrictive lung disease, 1 (1.6%) had mixed lung disease, and 6 (9.4%) had no clinical lung disease. Among the 58 subjects with clinical lung disease, 22 (37.9%), 37 (63.8%), 33 (56.9%), and 3 (5.2%) were classified as having obstructive pattern based on TLC, FEF25-75%, PEF, and post-bronchodilator response criteria, respectively. The kappa coefficients for the agreement between the clinical classification and PFT classification using TLC, FEF25-75%, PEF, and post-bronchodilator response criteria in 58 subjects were 0.59, 0.18, 0.17, and spirometry, when obstructive lung disease is clinically suspected. Copyright © 2016 by Daedalus Enterprises.

  9. Economic Assessment and Budgetary Impact of a Telemedicine Procedure and Spirometry Quality Control in the Primary Care Setting.

    Science.gov (United States)

    Marina, Nuria; Bayón, Juan Carlos; López de Santa María, Elena; Gutiérrez, Asunción; Inchausti, Marta; Bustamante, Victor; Gáldiz, Juan B

    2016-01-01

    To evaluate the economic impact of a telemedicine procedure designed to improve the quality of lung function testing (LFT) in primary care in a public healthcare system, compared with the standard method. The economic impact of 9,039 LFTs performed in 51 health centers (2010-2013) using telespirometry (TS) compared to standard spirometry (SS) was studied. TS costs more per unit than SS (€47.80 vs. €39.70) (2013), but the quality of the TS procedure is superior (84% good quality, compared to 61% using the standard procedure). Total cost of TS was €431,974 (compared with €358,306€ for SS), generating an economic impact of €73,668 (2013). The increase in cost for good quality LFT performed using TS was €34,030 (2010) and €144,295 (2013), while the costs of poor quality tests fell by €15,525 (2010) and 70,627€ (2013). The cost-effectiveness analysis concludes that TS is 23% more expensive and 46% more effective. Healthcare costs consequently fall as the number of LFTs performed by TS rises. Avoiding poor quality, invalid LFTs generates savings that compensate for the increased costs of performing LFTs with TS, making it a cost-effective method. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  10. Spirometry Findings Following Treatment with Oral and Inhalant Corticosteroids in Mild to Moderate Asthma Exacerbation in Children

    Directory of Open Access Journals (Sweden)

    Nemat Bilan

    2014-12-01

    Full Text Available Introduction:  Asthma exacerbation is common in children. Treatment with oral corticosteroids (OCS and inhaled corticosteroids are suggested for asthma exacerbation. It is shown that inhaled corticosteroids has similar outcome in reducing asthma symptoms compared to OCS. But few studies have evaluated the pulmonary function changes in these two treatments. In this study, we evaluated the changes in pulmonary function tests in children with mild-to-moderate asthma exacerbation receiving oral prednisolone and inhaled Budesonide. Methods and Materials: Forty-four children with mild-to-moderate asthma exacerbation were randomly assigned to receive oral prednisolone (2 mg/kg or Budesonide spray (2 puffs every 12 hours, each puff contains 200 microgram Budesonide using a spacer for one week. The first dose of the treatment was given in the emergency department. Children were followed for seven days and spirometry findings before and after treatment were evaluated. Results: There was no significant difference between pulmonary function tests before and after treatment between groups. Children receiving oral prednisolone had significantly more improvement in PEF (p=0.01. There was significant improvement in all respiratory parameters after treatment in both groups (p

  11. Spirometry and regular follow-up do not improve quality of life in children or adolescents with asthma: Cluster randomized controlled trials.

    Science.gov (United States)

    Abramson, Michael J; Schattner, Rosa L; Holton, Christine; Simpson, Pam; Briggs, Nancy; Beilby, Justin; Nelson, Mark R; Wood-Baker, Richard; Thien, Francis; Sulaiman, Nabil D; Colle, Eleonora Del; Wolfe, Rory; Crockett, Alan J; Massie, R John

    2015-10-01

    To determine whether spirometry and regular medical review improved quality of life or other outcomes in children and adolescents with asthma. We conducted two cluster randomized controlled trials. We recruited 238 asthma patients aged between 7 and 17 years from 56 general practices in South Eastern Australia. Participants were randomized to receive an intervention that included spirometry or usual care. The main outcome measure was asthma related quality of life. Baseline characteristics were well matched between the intervention and control groups. Neither trial found any difference in asthma related quality of life between groups. However because of measurement properties, a formal meta-analysis could not be performed. Nor were there any significant effects of the intervention upon asthma attacks, limitation to usual activities, nocturnal cough, bother during physical activity, worry about asthma, or written asthma action plans. The findings do not support more widespread use of spirometry for the management of childhood asthma in general practice, unless it is integrated into a complete management model. © 2014 Wiley Periodicals, Inc.

  12. A pilot study to monitor changes in spirometry and lung volume, following an exacerbation of Chronic Obstructive Pulmonary Disease (COPD), as part of a supported discharge program.

    Science.gov (United States)

    Cushen, Breda; McCormack, Niamh; Hennigan, Kerrie; Sulaiman, Imran; Costello, Richard W; Deering, Brenda

    2016-10-01

    One-third of patients with an exacerbation of Chronic Obstructive Pulmonary Disease(COPD) are re-hospitalised at 90 days. Exacerbation recovery is associated with reductions in lung hyperinflation and improvements in symptoms and physical activity. We assessed the feasibility of monitoring these clinical parameters in the home. We hypothesised that the degree of change in spirometry and lung volumes differs between those who had an uneventful recovery and those who experienced a further exacerbation. Hospitalised patients with an acute exacerbation of COPD referred for a supported discharge program participated in the study. Spirometry and Inspiratory Vital Capacity(IVC) were measured in the home at Days 1, 14 and 42 post-discharge. Patients also completed Medical Research Council(MRC), Borg and COPD Assessment Test(CAT) scores and were provided with a tri-axial accelerometer. Any new exacerbation events were recorded. Sixty-five patients with 72 exacerbation episodes were recruited. Fifty percent experienced a second exacerbation. Adequate IVC measurements were achieved by 90%, while only 70% completed spirometry. Uneventful recovery was accompanied by significant improvements in physiological measurements at day14, improved symptom scores and step count, p volumes, symptoms and step count following a COPD exacerbation may help to identify patients at risk of re-exacerbation. It is feasible to carry out these assessments in the home as part of a supported discharge programme. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Excessive crying in infants with regulatory disorders.

    Science.gov (United States)

    Maldonado-Duran, M; Sauceda-Garcia, J M

    1996-01-01

    The authors point out a correlation between regulatory disorders in infants and the problem of excessive crying. The literature describes other behavioral problems involving excessive crying in very young children, but with little emphasis on this association. The recognition and diagnosis of regulatory disorders in infants who cry excessively can help practitioners design appropriate treatment interventions. Understanding these conditions can also help parents tailor their caretaking style, so that they provide appropriate soothing and stimulation to their child. In so doing, they will be better able to develop and preserve a satisfactory parent-child relationship, as well as to maintain their own sense of competence and self-esteem as parents.

  14. Association between blood cholesterol and sodium intake in hypertensive women with excess weight.

    Science.gov (United States)

    Padilha, Bruna Merten; Ferreira, Raphaela Costa; Bueno, Nassib Bezerra; Tassitano, Rafael Miranda; Holanda, Lidiana de Souza; Vasconcelos, Sandra Mary Lima; Cabral, Poliana Coelho

    2018-04-01

    Restricted sodium intake has been recommended for more than 1 century for the treatment of hypertension. However, restriction seems to increase blood cholesterol. In women with excess weight, blood cholesterol may increase even more because of insulin resistance and the high lipolytic activity of adipose tissue.The aim of this study was to assess the association between blood cholesterol and sodium intake in hypertensive women with and without excess weight.This was a cross-sectional study with hypertensive and nondiabetic women aged 20 to 59 years, recruited at the primary healthcare units of Maceio, Alagoas, Brazilian Northeast. Excess weight was defined as body mass index (BMI) ≥25.0 kg/m. Sodium intake was estimated by the 24-hour urinary excretion of sodium. Blood cholesterol was the primary outcome investigated by this study, and its relationship with sodium intake and other variables was assessed by Pearson correlation and multivariate linear regression using a significance level of 5%.This study included 165 hypertensive women. Of these, 135 (81.8%) were with excess weight. The mean sodium intake was 3.7 g (±1.9) and 3.4 g (±2.4) in hypertensive women with and without excess weight, respectively. The multiple normal linear regression models fitted to the "blood cholesterol" in the 2 groups reveal that for the group of hypertensive women without excess weight only 1 independent variable "age" is statistically significant to explain the variability of the blood cholesterol levels. However, for the group of hypertensive women with excess weight, 2 independent variables, age and sodium intake, can statistically explain variations of the blood cholesterol levels.Blood cholesterol is statistically inversely related to sodium intake for hypertensive women with excess weight, but it is not statistically related to sodium intake for hypertensive women without excess weight.

  15. Predictors of excessive use of social media and excessive online gaming in Czech teenagers.

    Science.gov (United States)

    Spilková, Jana; Chomynová, Pavla; Csémy, Ladislav

    2017-12-01

    Background and aims Young people's involvement in online gaming and the use of social media are increasing rapidly, resulting in a high number of excessive Internet users in recent years. The objective of this paper is to analyze the situation of excessive Internet use among adolescents in the Czech Republic and to reveal determinants of excessive use of social media and excessive online gaming. Methods Data from secondary school students (N = 4,887) were collected within the 2015 European School Survey Project on Alcohol and Other Drugs. Logistic regression models were constructed to describe the individual and familial discriminative factors and the impact of the health risk behavior of (a) excessive users of social media and (b) excessive players of online games. Results The models confirmed important gender-specific distinctions - while girls are more prone to online communication and social media use, online gaming is far more prevalent among boys. The analysis did not indicate an influence of family composition on both the excessive use of social media and on excessive online gaming, and only marginal effects for the type of school attended. We found a connection between the excessive use of social media and binge drinking and an inverse relation between excessive online gaming and daily smoking. Discussion and conclusion The non-existence of significant associations between family environment and excessive Internet use confirmed the general, widespread of this phenomenon across the social and economic strata of the teenage population, indicating a need for further studies on the topic.

  16. A new approach to analyse longitudinal epidemiological data with an excess of zeros

    NARCIS (Netherlands)

    Spriensma, A.S.; Hajós, T.R.S.; de Boer, M.R.; Heijmans, M.W.; Twisk, J.W.R.

    2013-01-01

    Background: Within longitudinal epidemiological research, count outcome variables with an excess of zeros frequently occur. Although these outcomes are frequently analysed with a linear mixed model, or a Poisson mixed model, a two-part mixed model would be better in analysing outcome variables with

  17. A new approach to analyse longitudinal epidemiological data with an excess of zeros

    NARCIS (Netherlands)

    Spriensma, Alette S.; Hajos, Tibor R. S.; de Boer, Michiel R.; Heymans, Martijn W.; Twisk, Jos W. R.

    2013-01-01

    Background: Within longitudinal epidemiological research, 'count' outcome variables with an excess of zeros frequently occur. Although these outcomes are frequently analysed with a linear mixed model, or a Poisson mixed model, a two-part mixed model would be better in analysing outcome variables

  18. Explaining CMS lepton excesses with supersymmetry

    CERN Multimedia

    CERN. Geneva; Prof. Allanach, Benjamin

    2014-01-01

    1) Kostas Theofilatos will give an introduction to CMS result 2) Ben Allanach: Several CMS analyses involving di-leptons have recently reported small 2.4-2.8 sigma local excesses: nothing to get too excited about, but worth keeping an eye on nonetheless. In particular, a search in the $lljj p_T$(miss) channel, a search for $W_R$ in the $lljj$ channel and a di-leptoquark search in the $lljj$ channel and $ljj p_T$(miss) channel have all yielded small excesses. We interpret the first excess in the MSSM, showing that the interpretation is viable in terms of other constraints, despite only having squark masses of around 1 TeV. We can explain the last three excesses with a single R-parity violating coupling that predicts a non-zero contribution to the neutrinoless double beta decay rate.

  19. The High Price of Excessive Alcohol Consumption

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the October 2011 release of a report estimating the economic cost of excessive drinking. Excessive alcohol consumption cost the U. S. $223.5 billion in 2006, or about $1.90 per drink. Over three-quarters (76%) of these costs were due to binge drinking, defined as consuming 4 or more alcoholic beverages per occasion for women or 5 or more drinks per occasion for men.

  20. Romanian welfare state between excess and failure

    Directory of Open Access Journals (Sweden)

    Cristina Ciuraru-Andrica

    2012-12-01

    Full Text Available Timely or not, our issue can bring back to life some prolific discussions, sometimes diametrical. We strike the social assistance, where, at this moment, is still uncertain if, once unleashed the excess, the failure will come inevitably or there is a “Salvation Ark”. However, the difference between the excess and the failure of the welfare state is almost intangible, the reason of his potential failure being actually the abuses made until the start of depression.

  1. Brazilian air traffic controllers exhibit excessive sleepiness.

    Science.gov (United States)

    Ribas, Valdenilson Ribeiro; de Almeida, Cláudia Ângela Vilela; Martins, Hugo André de Lima; Alves, Carlos Frederico de Oliveira; Alves, Marcos José Pinheiro Cândido; Carneiro, Severino Marcos de Oliveira; Ribas, Valéria Ribeiro; de Vasconcelos, Carlos Augusto Carvalho; Sougey, Everton Botelho; de Castro, Raul Manhães

    2011-01-01

    Excessive sleepiness (ES) is an increased tendency to initiate involuntary sleep for naps at inappropriate times. The objective of this study was to assess ES in air traffic controllers (ATCo). 45 flight protection professionals were evaluated, comprising 30 ATCo, subdivided into ATCo with ten or more years in the profession (ATCo≥10, n=15) and ATCo with less than ten years in the profession (ATCoair traffic controllers exhibit excessive sleepiness.

  2. Impulse oscillometry at preschool age is a strong predictor of lung function by flow-volume spirometry in adolescence.

    Science.gov (United States)

    Lauhkonen, Eero; Riikonen, Riikka; Törmänen, Sari; Koponen, Petri; Nuolivirta, Kirsi; Helminen, Merja; Toikka, Jyri; Korppi, Matti

    2018-05-01

    The transition from early childhood wheezing to persistent asthma is linked to lung function impairment over time. Little is known how the methods used to study lung function at different ages correlate longitudinally. Sixty-four children with a history of hospitalization for bronchiolitis before 6 months of age were prospectively studied with impulse oscillometry (IOS) at the mean age of 6.3 years and these preschool IOS results were compared with flow-volume spirometry (FVS) measurements at mean age of 11.4 years. The baseline respiratory system resistance at 5 Hz (Rrs5) showed a modest statistically significant correlation with all baseline FVS parameters except FVC. The post-bronchodilator (post-BD) Rrs5 showed a modest statistically significant correlation with post-BD FEV 1 and FEV 1 /FVC. The bronchodilator-induced decrease in Rrs5 showed a modest statistically significant correlation with the percent increase in FEV 1 . Baseline and post-BD respiratory reactance at 5 Hz (Xrs5) showed a modest statistically significant correlation with baseline and post-BD FVS parameters except post-BD FEV 1 /FVC, respectively, and post-BD Xrs5 showed a strong correlation with post-BD FVC (ρ = 0.61) and post-BD FEV 1 (ρ = 0.59). In adjusted linear regression, preschool Xrs5 remained as a statistically significant independent predictor of FVS parameters in adolescence; the one-unit decrease in the Z-score of preschool post-BD Xrs5 predicted 9.6% lower post-BD FEV 1 , 9.3% lower post-BD FVC, and 9.7% lower post-BD MEF 50 when expressed as %-predicted parameters. Persistent post-BD small airway impairment in children with a history of bronchiolitis detected with IOS at preschool age predicted FVS results measured in early adolescence. © 2018 Wiley Periodicals, Inc.

  3. Antidepressant induced excessive yawning and indifference

    Directory of Open Access Journals (Sweden)

    Bruno Palazzo Nazar

    2015-03-01

    Full Text Available Introduction Antidepressant induced excessive yawning has been described as a possible side effect of pharmacotherapy. A syndrome of indifference has also been described as another possible side effect. The frequency of those phenomena and their physiopathology are unknown. They are both considered benign and reversible after antidepressant discontinuation but severe cases with complications as temporomandibular lesions, have been described. Methods We report two unprecedented cases in which excessive yawning and indifference occurred simultaneously as side effects of antidepressant therapy, discussing possible physiopathological mechanisms for this co-occurrence. Case 1: A male patient presented excessive yawning (approximately 80/day and apathy after venlafaxine XR treatment. Symptoms reduced after a switch to escitalopram, with a reduction to 50 yawns/day. Case 2: A female patient presented excessive yawning (approximately 25/day and inability to react to environmental stressors with desvenlafaxine. Conclusion Induction of indifference and excessive yawning may be modulated by serotonergic and noradrenergic mechanisms. One proposal to unify these side effects would be enhancement of serotonin in midbrain, especially paraventricular and raphe nucleus.

  4. New vector bosons and the diphoton excess

    Directory of Open Access Journals (Sweden)

    Jorge de Blas

    2016-08-01

    Full Text Available We consider the possibility that the recently observed diphoton excess at ∼750 GeV can be explained by the decay of a scalar particle (φ to photons. If the scalar is the remnant of a symmetry-breaking sector of some new gauge symmetry, its coupling to photons can be generated by loops of the charged massive vectors of the broken symmetry. If these new W′ vector bosons carry color, they can also generate an effective coupling to gluons. In this case the diphoton excess could be entirely explained in a simplified model containing just φ and W′. On the other hand, if W′ does not carry color, we show that, provided additional colored particles exist to generate the required φ to gluon coupling, the diphoton excess could be explained by the same W′ commonly invoked to explain the diboson excess at ∼2 TeV. We also explore possible connections between the diphoton and diboson excesses with the anomalous tt¯ forward–backward asymmetry.

  5. Limiting law excess sum rule for polyelectrolytes.

    Science.gov (United States)

    Landy, Jonathan; Lee, YongJin; Jho, YongSeok

    2013-11-01

    We revisit the mean-field limiting law screening excess sum rule that holds for rodlike polyelectrolytes. We present an efficient derivation of this law that clarifies its region of applicability: The law holds in the limit of small polymer radius, measured relative to the Debye screening length. From the limiting law, we determine the individual ion excess values for single-salt electrolytes. We also consider the mean-field excess sum away from the limiting region, and we relate this quantity to the osmotic pressure of a dilute polyelectrolyte solution. Finally, we consider numerical simulations of many-body polymer-electrolyte solutions. We conclude that the limiting law often accurately describes the screening of physical charged polymers of interest, such as extended DNA.

  6. Explaining excess morbidity amongst homeless shelter users

    DEFF Research Database (Denmark)

    Benjaminsen, Lars; Birkelund, Jesper Fels

    2018-01-01

    AIMS: This article analyses excess morbidity amongst homeless shelter users compared to the general Danish population. The study provides an extensive control for confounding and investigates to what extent excess morbidity is explained by homelessness or other risk factors. METHODS: Data set...... includes administrative micro-data for 4,068,926 Danes who were 23 years or older on 1 January 2007. Nationwide data on shelter use identified 14,730 individuals as shelter users from 2002 to 2006. Somatic diseases were measured from 2007 to 2011 through diagnosis data from hospital discharges. The risk...... of somatic diseases amongst shelter users was analysed through a multivariate model that decomposed the total effect into a direct effect and indirect effects mediated by other risk factors. RESULTS: The excess morbidity associated with shelter use is substantially lower than in studies that did not include...

  7. The High Price of Excessive Alcohol Consumption

    Centers for Disease Control (CDC) Podcasts

    2011-10-17

    This podcast is based on the October 2011 release of a report estimating the economic cost of excessive drinking. Excessive alcohol consumption cost the U. S. $223.5 billion in 2006, or about $1.90 per drink. Over three-quarters (76%) of these costs were due to binge drinking, defined as consuming 4 or more alcoholic beverages per occasion for women or 5 or more drinks per occasion for men.  Created: 10/17/2011 by National Center for Chronic Disease Prevention and Health Promotion.   Date Released: 10/17/2011.

  8. On the excess energy of nonequilibrium plasma

    International Nuclear Information System (INIS)

    Timofeev, A. V.

    2012-01-01

    The energy that can be released in plasma due to the onset of instability (the excess plasma energy) is estimated. Three potentially unstable plasma states are considered, namely, plasma with an anisotropic Maxwellian velocity distribution of plasma particles, plasma with a two-beam velocity distribution, and an inhomogeneous plasma in a magnetic field with a local Maxwellian velocity distribution. The excess energy can serve as a measure of the degree to which plasma is nonequilibrium. In particular, this quantity can be used to compare plasmas in different nonequilibrium states.

  9. 26 CFR 54.4981A-1T - Tax on excess distributions and excess accumulations (temporary).

    Science.gov (United States)

    2010-04-01

    ... Revenue Code of 1986, as added by section 1133 of the Tax Reform Act of 1986 (Pub. L. 99-514) (TRA '86...) Determine the value of the individual's adjusted account balance on the next valuation date by adding (or... 26 Internal Revenue 17 2010-04-01 2010-04-01 false Tax on excess distributions and excess...

  10. Excessive daytime sleepiness among depressed patients | Mume ...

    African Journals Online (AJOL)

    Background: Excessive daytime sleepiness (EDS) has been reported among depressed patients in many populations. Many depressed patients seek medical attention partly to deal with EDS, but this sleep disorder is often overlooked in clinical practice. Objectives: The objectives of this study were to determine the ...

  11. Excessive daytime sleepiness, nocturnal sleep duration and ...

    African Journals Online (AJOL)

    Background and objectives. Short nocturnal sleep duration resulting in sleep debt may be a cause of excessive daytime sleepiness (EDS). Severity of depression (psychopathology) has been found to be directly related to EDS. There is an association between sleep duration and mental health, so there may therefore be an ...

  12. Can Excess Bilirubin Levels Cause Learning Difficulties?

    Science.gov (United States)

    Pretorius, E.; Naude, H.; Becker, P. J.

    2002-01-01

    Examined learning problems in South African sample of 7- to 14-year-olds whose mothers reported excessively high infant bilirubin shortly after the child's birth. Found that this sample had lowered verbal ability with the majority also showing impaired short-term and long-term memory. Findings suggested that impaired formation of astrocytes…

  13. Excessive daytime sleepiness among depressed patients | Mume ...

    African Journals Online (AJOL)

    Abstract. Background: Excessive daytime sleepiness (EDS) has been reported among depressed patients in many populations. Many depressed patients seek medical attention partly to deal with EDS, but this sleep disorder is often overlooked in clinical practice. Objectives: The objectives of this study were to determine the ...

  14. Phospholipids as Biomarkers for Excessive Alcohol Use

    Science.gov (United States)

    2013-10-01

    NUMBER Phospholipids as Biomarkers for Excessive Alcohol Use 5b. GRANT NUMBER W81XWH-12-1-0497 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...suspected of alcohol abuse. Toxicol Lett, 151(1), 235-241. Graham, D. P., Cardon , A. L., & Uhl, G. R. (2008). An update on substance use and treatment

  15. Excessive infant crying: Definitions determine risk groups

    NARCIS (Netherlands)

    Reijneveld, S.A.; Brugman, E.; Hirasing, R.A.

    2002-01-01

    We assessed risk groups for excessive infant crying using 10 published definitions, in 3179 children aged 1-6 months (response: 96.5%). Risk groups regarding parental employment, living area, lifestyle, and obstetric history varied by definition. This may explain the existence of conflicting

  16. Excessive prices as abuse of dominance?

    DEFF Research Database (Denmark)

    la Cour, Lisbeth; Møllgaard, Peter

    2007-01-01

    firm abused its position by charging excessive prices. We also test whether tightening of the Danish competition act has altered the pricing behaviour on the market. We discuss our results in the light of a Danish competition case against the dominant cement producer that was abandoned by the authority...

  17. Excessive oral intake caffeine altered cerebral cortex ...

    African Journals Online (AJOL)

    Caffeine is commonly consumed in an effort to enhance speed in performance and wakefulness. However, little is known about the deleterious effects it can produce on the brain, this study aimed at determining the extents of effects and damage that can be caused by excessive consumption of caffeine on the cerebral cortex ...

  18. 43 CFR 426.12 - Excess land.

    Science.gov (United States)

    2010-10-01

    ... advertise the sale of the property in farm journals and in newspapers within the county in which the land...; (ii) A recordable contract is amended to remove excess land when the landowner's entitlement increases... eligible buyer at a price and on terms approved by Reclamation; (C) The sale from the previous landowner is...

  19. Excessive Gambling and Online Gambling Communities.

    Science.gov (United States)

    Sirola, Anu; Kaakinen, Markus; Oksanen, Atte

    2018-04-05

    The Internet provides an accessible context for online gambling and gambling-related online communities, such as discussion forums for gamblers. These communities may be particularly attractive to young gamblers who are active Internet users. The aim of this study was to examine the use of gambling-related online communities and their relevance to excessive gambling among 15-25-year-old Finnish Internet users (N = 1200). Excessive gambling was assessed by using the South Oaks Gambling Screen. Respondents were asked in a survey about their use of various kinds of gambling-related online communities, and sociodemographic and behavioral factors were adjusted. The results of the study revealed that over half (54.33%) of respondents who had visited gambling-related online communities were either at-risk gamblers or probable pathological gamblers. Discussion in these communities was mainly based on sharing gambling tips and experiences, and very few respondents said that they related to gambling problems and recovery. In three different regression models, visiting gambling-related online communities was a significant predictor for excessive gambling (with 95% confidence level) even after adjusting confounding factors. The association of visiting such sites was even stronger among probable pathological gamblers than among at-risk gamblers. Health professionals working with young people should be aware of the role of online communities in terms of development and persistence of excessive gambling. Monitoring the use of online gambling communities as well as utilizing recovery-oriented support both offline and online would be important in preventing further problems. Gambling platforms should also include warnings about excessive gambling and provide links to helpful sources.

  20. Excess Readmission vs Excess Penalties: Maximum Readmission Penalties as a Function of Socioeconomics and Geography.

    Science.gov (United States)

    Caracciolo, Chris; Parker, Devin; Marshall, Emily; Brown, Jeremiah

    2017-08-01

    The Hospital Readmission Reduction Program (HRRP) penalizes hospitals with "excess" readmissions up to 3% of Medicare reimbursement. Approximately 75% of eligible hospitals received penalties, worth an estimated $428 million, in fiscal year 2015. To identify demographic and socioeconomic disparities between matched and localized maximum-penalty and no-penalty hospitals. A case-control study in which cases included were hospitals to receive the maximum 3% penalty under the HRRP during the 2015 fiscal year. Controls were drawn from no-penalty hospitals and matched to cases by hospital characteristics (primary analysis) or geographic proximity (secondary analysis). A selectiion of 3383 US hospitals eligible for HRRP. Thirty-nine case and 39 control hospitals from the HRRP cohort. Socioeconomic status variables were collected by the American Community Survey. Hospital and health system characteristics were drawn from Centers for Medicare and Medicaid Services, American Hospital Association, and Dartmouth Atlas of Health Care. The statistical analysis was conducted using Student t tests. Thirty-nine hospitals received a maximum penalty. Relative to controls, maximum-penalty hospitals in counties with lower SES profiles are defined by increased poverty rates (19.1% vs 15.5%, = 0.015) and lower rates of high school graduation (82.2% vs 87.5%, = 0.001). County level age, sex, and ethnicity distributions were similar between cohorts. Cases were more likely than controls to be in counties with low socioeconomic status; highlighting potential unintended consequences of national benchmarks for phenomena underpinned by environmental factors; specifically, whether maximum penalties under the HRRP are a consequence of underperforming hospitals or a manifestation of underserved communities. © 2017 Society of Hospital Medicine

  1. Altered cardiorespiratory coupling in young male adults with excessive online gaming.

    Science.gov (United States)

    Chang, Jae Seung; Kim, Eun Young; Jung, Dooyoung; Jeong, Seong Hoon; Kim, Yeni; Roh, Myoung-Sun; Ahn, Yong Min; Hahm, Bong-Jin

    2015-09-01

    This study aimed to investigate changes in heart rate variability and cardiorespiratory coupling in male college students with problematic Internet use (PIU) excessive gaming type during action video game play to assess the relationship between PIU tendency and central autonomic regulation. Electrocardiograms and respiration were simultaneously recorded from 22 male participants with excessive online gaming and 22 controls during action video game play. Sample entropy (SampEn) was computed to assess autonomic regularity, and cross-SampEn was calculated to quantify autonomic coordination. During video game play, reduced cardiorespiratory coupling (CRC) was observed in individuals with PIU excessive gaming type compared with controls, implicating central autonomic dysregulation. The PIU tendency was associated with the severity of autonomic dysregulation. These findings indicate impaired CRC in PIU excessive gaming type, which may reflect alterations of central inhibitory control over autonomic responses to pleasurable online stimuli. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Quantitative computed tomography analysis of the airways in patients with cystic fibrosis using automated software: correlation with spirometry in the evaluation of severity

    International Nuclear Information System (INIS)

    Santos, Marcel Koenigkam; Cruvinel, Danilo Lemos; Menezes, Marcelo Bezerra de; Teixeira, Sara Reis; Vianna, Elcio de Oliveira; Elias Junior, Jorge; Martinez, Jose Antonio Baddini

    2016-01-01

    Objective: To perform a quantitative analysis of the airways using automated software, in computed tomography images of patients with cystic fibrosis, correlating the results with spirometric findings. Materials and methods: Thirty-four patients with cystic fibrosis were studied-20 males and 14 females; mean age 18 ± 9 years - divided into two groups according to the spirometry findings: group I (n = 21), without severe airflow obstruction (forced expiratory volume in first second [FEV1] > 50% predicted), and group II (n = 13), with severe obstruction (FEV1 ≤ 50% predicted). The following tracheobronchial tree parameters were obtained automatically: bronchial diameter, area, thickness, and wall attenuation. Results: On average, 52 bronchi per patient were studied. The number of bronchi analyzed was higher in group II. The correlation with spirometry findings, especially between the relative wall thickness of third to eighth bronchial generation and predicted FEV1, was better in group I. Conclusion: Quantitative analysis of the airways by computed tomography can be useful for assessing disease severity in cystic fibrosis patients. In patients with severe airflow obstruction, the number of bronchi studied by the method is higher, indicating more bronchiectasis. In patients without severe obstruction, the relative bronchial wall thickness showed a good correlation with the predicted FEV1. (author)

  3. Quantitative computed tomography analysis of the airways in patients with cystic fibrosis using automated software: correlation with spirometry in the evaluation of severity

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcel Koenigkam; Cruvinel, Danilo Lemos; Menezes, Marcelo Bezerra de; Teixeira, Sara Reis; Vianna, Elcio de Oliveira; Elias Junior, Jorge; Martinez, Jose Antonio Baddini, E-mail: marcelk46@yahoo.com.br [Universidade de Sao Paulo (HC/FMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina

    2016-11-15

    Objective: To perform a quantitative analysis of the airways using automated software, in computed tomography images of patients with cystic fibrosis, correlating the results with spirometric findings. Materials and methods: Thirty-four patients with cystic fibrosis were studied-20 males and 14 females; mean age 18 ± 9 years - divided into two groups according to the spirometry findings: group I (n = 21), without severe airflow obstruction (forced expiratory volume in first second [FEV1] > 50% predicted), and group II (n = 13), with severe obstruction (FEV1 ≤ 50% predicted). The following tracheobronchial tree parameters were obtained automatically: bronchial diameter, area, thickness, and wall attenuation. Results: On average, 52 bronchi per patient were studied. The number of bronchi analyzed was higher in group II. The correlation with spirometry findings, especially between the relative wall thickness of third to eighth bronchial generation and predicted FEV1, was better in group I. Conclusion: Quantitative analysis of the airways by computed tomography can be useful for assessing disease severity in cystic fibrosis patients. In patients with severe airflow obstruction, the number of bronchi studied by the method is higher, indicating more bronchiectasis. In patients without severe obstruction, the relative bronchial wall thickness showed a good correlation with the predicted FEV1. (author)

  4. ILLUSION OF EXCESSIVE CONSUMPTION AND ITS EFFECTS

    Directory of Open Access Journals (Sweden)

    MUNGIU-PUPĂZAN MARIANA CLAUDIA

    2015-12-01

    Full Text Available The aim is to explore, explain and describe this phenomenon to a better understanding of it and also the relationship between advertising and the consumer society members. This paper aims to present an analysis of excessive and unsustainable consumption, the evolution of a phenomenon, and the ability to find a way to combat. Unfortunately, studies show that this tendency to accumulate more than we need to consume excess means that almost all civilizations fined and placed dogmatic among the values that children learn early in life. This has been perpetuated since the time when the goods or products does not get so easy as today. Anti-consumerism has emerged in response to this economic system, not on the long term. We are witnessing the last two decades to establish a new phase of consumer capitalism: society hiperconsumtion.

  5. Excess plutonium disposition: The deep borehole option

    International Nuclear Information System (INIS)

    Ferguson, K.L.

    1994-01-01

    This report reviews the current status of technologies required for the disposition of plutonium in Very Deep Holes (VDH). It is in response to a recent National Academy of Sciences (NAS) report which addressed the management of excess weapons plutonium and recommended three approaches to the ultimate disposition of excess plutonium: (1) fabrication and use as a fuel in existing or modified reactors in a once-through cycle, (2) vitrification with high-level radioactive waste for repository disposition, (3) burial in deep boreholes. As indicated in the NAS report, substantial effort would be required to address the broad range of issues related to deep bore-hole emplacement. Subjects reviewed in this report include geology and hydrology, design and engineering, safety and licensing, policy decisions that can impact the viability of the concept, and applicable international programs. Key technical areas that would require attention should decisions be made to further develop the borehole emplacement option are identified

  6. Subdwarf ultraviolet excesses and metal abundances

    International Nuclear Information System (INIS)

    Carney, B.W.

    1979-01-01

    The relation between stellar ultraviolet excesses and abundances is reexamined with the aid of new data, and an investigation is made of the accuracy of previous abundance analyses. A high-resolution echellogram of the subdwarf HD 201891 is analyzed to illustrate some of the problems. Generally, the earliest and latest analytical techniques yield consistent results for dwarfs. New UBV data yield normalized ultraviolet excesses, delta (U-B)/sub 0.6/, which are compared to abundances to produce a graphical relation that may be used to estimate [Fe/H] to +- 0.2 dex, given UBV colors accurate to +- 0.01 mag. The relation suggests a possible discontinuity between the halo and old-disk stars

  7. Neurological manifestations of excessive alcohol consumption.

    Science.gov (United States)

    Planas-Ballvé, Anna; Grau-López, Laia; Morillas, Rosa María; Planas, Ramón

    2017-12-01

    This article reviews the different acute and chronic neurological manifestations of excessive alcohol consumption that affect the central or peripheral nervous system. Several mechanisms can be implicated depending on the disorder, ranging from nutritional factors, alcohol-related toxicity, metabolic changes and immune-mediated mechanisms. Recognition and early treatment of these manifestations is essential given their association with high morbidity and significantly increased mortality. Copyright © 2017 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  8. Equine goiter associated with excess dietary iodine.

    Science.gov (United States)

    Eroksuz, H; Eroksuz, Y; Ozer, H; Ceribasi, A O; Yaman, I; Ilhan, N

    2004-06-01

    Naturally occurring goiter cases are described in 2 newborn Arabian foals whose mares were supplemented with excess iodine during the final 24 w of the pregnancy. Six nursing foals and 2 mares were also affected clinically with thyroid hypertrophy. At least 12 times the maximum tolerable level of iodine supplementation was given, as the daily iodine intake for each mare was 299 mg. The prevalence of goiter cases was 2 and 9% in the mares and foals, respectively.

  9. Contrast induced hyperthyroidism due to iodine excess

    OpenAIRE

    Mushtaq, Usman; Price, Timothy; Laddipeerla, Narsing; Townsend, Amanda; Broadbridge, Vy

    2009-01-01

    Iodine induced hyperthyroidism is a thyrotoxic condition caused by exposure to excessive iodine. Historically this type of hyperthyroidism has been described in areas of iodine deficiency. With advances in medicine, iodine induced hyperthyroidism has been observed following the use of drugs containing iodine—for example, amiodarone, and contrast agents used in radiological imaging. In elderly patients it is frequently difficult to diagnose and control contrast related hyperthyroidism, as most...

  10. Excessive current in wide superconducting films

    International Nuclear Information System (INIS)

    Volotskaya, V.G.; Sivakov, A.G.; Turutanov, O.G.

    1986-01-01

    The resistive state of a wide long film due to superconductivity destruction by current is studied. The voltage-independent excess current I 0 is observed on I-V curves at high transport currents. The two-dimensional image of the current-carrying sample obtained by laser scanning technique in this current range indicates that the whole film is in the resistive state. The current I 0 is measured as a function of magnetic field and SHF power

  11. Search for bright stars with infrared excess

    Energy Technology Data Exchange (ETDEWEB)

    Raharto, Moedji, E-mail: moedji@as.itb.ac.id [Astronomy Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia)

    2014-03-24

    Bright stars, stars with visual magnitude smaller than 6.5, can be studied using small telescope. In general, if stars are assumed as black body radiator, then the color in infrared (IR) region is usually equal to zero. Infrared data from IRAS observations at 12 and 25μm (micron) with good flux quality are used to search for bright stars (from Bright Stars Catalogues) with infrared excess. In magnitude scale, stars with IR excess is defined as stars with IR color m{sub 12}−m{sub 25}>0; where m{sub 12}−m{sub 25} = −2.5log(F{sub 12}/F{sub 25})+1.56, where F{sub 12} and F{sub 25} are flux density in Jansky at 12 and 25μm, respectively. Stars with similar spectral type are expected to have similar color. The existence of infrared excess in the same spectral type indicates the existence of circum-stellar dust, the origin of which is probably due to the remnant of pre main-sequence evolution during star formation or post AGB evolution or due to physical process such as the rotation of those stars.

  12. Earnings Quality Measures and Excess Returns.

    Science.gov (United States)

    Perotti, Pietro; Wagenhofer, Alfred

    2014-06-01

    This paper examines how commonly used earnings quality measures fulfill a key objective of financial reporting, i.e., improving decision usefulness for investors. We propose a stock-price-based measure for assessing the quality of earnings quality measures. We predict that firms with higher earnings quality will be less mispriced than other firms. Mispricing is measured by the difference of the mean absolute excess returns of portfolios formed on high and low values of a measure. We examine persistence, predictability, two measures of smoothness, abnormal accruals, accruals quality, earnings response coefficient and value relevance. For a large sample of US non-financial firms over the period 1988-2007, we show that all measures except for smoothness are negatively associated with absolute excess returns, suggesting that smoothness is generally a favorable attribute of earnings. Accruals measures generate the largest spread in absolute excess returns, followed by smoothness and market-based measures. These results lend support to the widespread use of accruals measures as overall measures of earnings quality in the literature.

  13. Internet addiction or excessive internet use.

    Science.gov (United States)

    Weinstein, Aviv; Lejoyeux, Michel

    2010-09-01

    Problematic Internet addiction or excessive Internet use is characterized by excessive or poorly controlled preoccupations, urges, or behaviors regarding computer use and Internet access that lead to impairment or distress. Currently, there is no recognition of internet addiction within the spectrum of addictive disorders and, therefore, no corresponding diagnosis. It has, however, been proposed for inclusion in the next version of the Diagnostic and Statistical Manual of Mental Disorder (DSM). To review the literature on Internet addiction over the topics of diagnosis, phenomenology, epidemiology, and treatment. Review of published literature between 2000-2009 in Medline and PubMed using the term "internet addiction. Surveys in the United States and Europe have indicated prevalence rate between 1.5% and 8.2%, although the diagnostic criteria and assessment questionnaires used for diagnosis vary between countries. Cross-sectional studies on samples of patients report high comorbidity of Internet addiction with psychiatric disorders, especially affective disorders (including depression), anxiety disorders (generalized anxiety disorder, social anxiety disorder), and attention deficit hyperactivity disorder (ADHD). Several factors are predictive of problematic Internet use, including personality traits, parenting and familial factors, alcohol use, and social anxiety. Although Internet-addicted individuals have difficulty suppressing their excessive online behaviors in real life, little is known about the patho-physiological and cognitive mechanisms responsible for Internet addiction. Due to the lack of methodologically adequate research, it is currently impossible to recommend any evidence-based treatment of Internet addiction.

  14. The Role of Androgen Excess in Metabolic Dysfunction in Women : Androgen Excess and Female Metabolic Dysfunction.

    Science.gov (United States)

    Escobar-Morreale, Héctor F

    2017-01-01

    Polycystic ovary syndrome (PCOS) is characterized by the association of androgen excess with chronic oligoovulation and/or polycystic ovarian morphology, yet metabolic disorders and classic and nonclassic cardiovascular risk factors cluster in these women from very early in life. This chapter focuses on the mechanisms underlying the association of PCOS with metabolic dysfunction, focusing on the role of androgen excess on the development of visceral adiposity and adipose tissue dysfunction.

  15. Analisis Faktor Fundamental Terhadap Excess Return Saham Syariah Perusahaan Jakarta Islamic Index

    Directory of Open Access Journals (Sweden)

    Azwar Azwar

    2016-02-01

    Full Text Available The study concluded that based on the result of testing by using multiple regression analysis. There are four variables that significantly affect the excess return variables, they are: BV, DER, ROE and SWBI. Besides, they are other variables such as PER, inflation, and exchange rate had no significant effect on the variables excess stock returns. Thus, it can be assumed that the JII firms during the study period was fulfiling aspects of sharia compliance. The indications are book value can represent the real value of the assets of the company itself and the highest ratio of debt to asset is 2.84%, meanwhile the highest determination of Islamic National Council is 33%DOI: 10.15408/aiq.v3i1.2221

  16. Bronchodilator response cut-off points and FEV 0.75 reference values for spirometry in preschoolers.

    Science.gov (United States)

    Burity, Edjane Figueiredo; Pereira, Carlos Alberto de Castro; Jones, Marcus Herbert; Sayão, Larissa Bouwman; Andrade, Armèle Dornelas de; Britto, Murilo Carlos Amorim de

    2016-01-01

    To determine the cut-off points for FEV1, FEV0.75, FEV0.5, and FEF25-75% bronchodilator responses in healthy preschool children and to generate reference values for FEV0.75. This was a cross-sectional community-based study involving children 3-5 years of age. Healthy preschool children were selected by a standardized questionnaire. Spirometry was performed before and after bronchodilator use. The cut-off point of the response was defined as the 95th percentile of the change in each parameter. We recruited 266 children, 160 (60%) of whom were able to perform acceptable, reproducible expiratory maneuvers before and after bronchodilator use. The mean age and height were 57.78 ± 7.86 months and 106.56 ± 6.43 cm, respectively. The success rate for FEV0.5 was 35%, 68%, and 70% in the 3-, 4-, and 5-year-olds, respectively. The 95th percentile of the change in the percentage of the predicted value in response to bronchodilator use was 11.6%, 16.0%, 8.5%, and 35.5% for FEV1, FEV0.75, FEV0.5, and FEF25-75%, respectively. Our results provide cut-off points for bronchodilator responsiveness for FEV1, FEV0.75, FEV0.5, and FEF25-75% in healthy preschool children. In addition, we proposed gender-specific reference equations for FEV0.75. Our findings could improve the physiological assessment of respiratory function in preschool children. Determinar os pontos de corte de resposta ao broncodilatador do VEF1, VEF0,75, VEF0,5 e FEF25-75% em crianças pré-escolares saudáveis e gerar valores de referência para o VEF0,75. Foi realizado um estudo transversal de base comunitária em crianças de 3-5 anos de idade. Pré-escolares saudáveis foram selecionados por um questionário padronizado. Foi realizada espirometria antes e depois do uso de broncodilatador. Foram definidos os pontos de corte dessa resposta como o percentil 95 de variação em cada parâmetro. Foram recrutadas 266 crianças, e 160 (60,0%) foram capazes de gerar manobras expiratórias aceitáveis e reprodut

  17. Variability Bugs:

    DEFF Research Database (Denmark)

    Melo, Jean

    . Although many researchers suggest that preprocessor-based variability amplifies maintenance problems, there is little to no hard evidence on how actually variability affects programs and programmers. Specifically, how does variability affect programmers during maintenance tasks (bug finding in particular......)? How much harder is it to debug a program as variability increases? How do developers debug programs with variability? In what ways does variability affect bugs? In this Ph.D. thesis, I set off to address such issues through different perspectives using empirical research (based on controlled...... experiments) in order to understand quantitatively and qualitatively the impact of variability on programmers at bug finding and on buggy programs. From the program (and bug) perspective, the results show that variability is ubiquitous. There appears to be no specific nature of variability bugs that could...

  18. Excessive sleep duration and quality of life.

    Science.gov (United States)

    Ohayon, Maurice M; Reynolds, Charles F; Dauvilliers, Yves

    2013-06-01

    Using population-based data, we document the comorbidities (medical, neurologic, and psychiatric) and consequences for daily functioning of excessive quantity of sleep (EQS), defined as a main sleep period or 24-hour sleep duration ≥ 9 hours accompanied by complaints of impaired functioning or distress due to excessive sleep, and its links to excessive sleepiness. A cross-sectional telephone study using a representative sample of 19,136 noninstitutionalized individuals living in the United States, aged ≥ 18 years (participation rate = 83.2%). The Sleep-EVAL expert system administered questions on life and sleeping habits; health; and sleep, mental, and organic disorders (Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revision; International Classification of Sleep Disorders: Diagnostic and Coding Manual II, International Classification of Diseases and Related Health Problems, 10th edition). Sleeping at least 9 hours per 24-hour period was reported by 8.4% (95% confidence interval = 8.0-8.8%) of participants; EQS (prolonged sleep episode with distress/impairment) was observed in 1.6% (1.4-1.8%) of the sample. The likelihood of EQS was 3 to 12× higher among individuals with a mood disorder. EQS individuals were 2 to 4× more likely to report poor quality of life than non-EQS individuals as well as interference with socioprofessional activities and relationships. Although between 33 and 66% of individuals with prolonged sleep perceived it as a major problem, only 6.3 to 27.5% of them reported having sought medical attention. EQS is widespread in the general population, co-occurring with a broad spectrum of sleep, medical, neurologic, and psychiatric disorders. Therefore, physicians must recognize EQS as a mixed clinical entity indicating careful assessment and specific treatment planning. © 2013 American Neurological Association.

  19. Severe excessive daytime sleepiness induced by hydroxyurea.

    Science.gov (United States)

    Revol, Bruno; Joyeux-Faure, Marie; Albahary, Marie-Victoire; Gressin, Remy; Mallaret, Michel; Pepin, Jean-Louis; Launois, Sandrine H

    2017-06-01

    Excessive daytime sleepiness (EDS) has been reported with many drugs, either as an extension of a hypnotic effect (e.g. central nervous system depressants) or as an idiosyncratic response of the patient. Here, we report unexpected and severe subjective and objective EDS induced by hydroxyurea therapy, with a favorable outcome after withdrawal. Clinical history, sleep log, polysomnography, and multiple sleep latency tests confirming the absence of other EDS causes are presented. © 2016 Société Française de Pharmacologie et de Thérapeutique.

  20. psi and excess leptons in photoproduction

    International Nuclear Information System (INIS)

    Ritson, D.M.

    1976-03-01

    The A-dependence of psi photoproduction was measured on beryllium and tantalum. From this it is found sigma/sub psi N/ = 2.75 +- 0.90 mb. A study was made of excess leptons relative to pion production in photoproduction. A μ/π ratio of 1.40 +- 0.25 x 10 -4 was found at 20 GeV incident photon energy. The energy dependence of psi photoproduction was determined and appeared to have a ''pseudo-threshold'' at 12 GeV

  1. Desaturation of excess intramyocellular triacylglycerol in obesity

    DEFF Research Database (Denmark)

    Haugaard, S B; Madsbad, S; Mu, Huiling

    2010-01-01

    , however, was increased twofold in obese women compared to obese men (Pfasting glucose (P...OBJECTIVE: Excess intramyocellular triacylglycerol (IMTG), found especially in obese women, is slowly metabolized and, therefore, prone to longer exposure to intracellular desaturases. Accordingly, it was hypothesized that IMTG content correlates inversely with IMTG fatty acid (FA) saturation...... in sedentary subjects. In addition, it was validated if IMTG palmitic acid is associated with insulin resistance as suggested earlier. DESIGN: Cross-sectional human study. SUBJECTS: In skeletal muscle biopsies, which were obtained from sedentary subjects (34 women, age 48+/-2 years (27 obese including 7 type 2...

  2. Conservative treatment of excessive anterior pelvic tilt

    DEFF Research Database (Denmark)

    Brekke, Anders Falk

    of Clinical Research, University of Southern Denmark, Denmark 3Department of Physiotherapy, University College Zealand, Denmark 4Center for Evidence-Based Medicine, Odense University Hospital, Denmark Correspondence Anders Falk Brekke E-mail: afbrekke@health.sdu.dk Mob: +45 7248 2626 Add: Sdr. Boulevard 29......Conservative treatment of excessive anterior pelvic tilt: A systematic review Anders Falk Brekke1,2,3, Søren Overgaard1,2, Asbjørn Hróbjartsson4, Anders Holsgaard-Larsen1,2 1Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital 2Department...

  3. Experimental and predicted data of excess molar enthalpies and excess molar volumes for the ternary system (1,3-dichlorobenzene + benzene + 1-chlorohexane) at T = 298.15 K

    International Nuclear Information System (INIS)

    Mato, Marta M.; Verdes, Pedro V.; Paz Andrade, M.I.; Legido, José Luis

    2014-01-01

    Graphical abstract: - Highlights: • Experimental enthalpy and densitiy for the mixture 1,3-dichlorobenzene + benzene + 1-chlorohexane were measured. • The excess molar volumes were calculated from the densities of the pure liquids and their mixtures. • The Cibulka equation was used to correlate the ternary contribution of the excess molar properties. • The experimental data were used to test several empirical equations. - Abstract: Experimental excess molar enthalpies, densities and excess molar volumes for the ternary system {x 1 1,3-dichlorobenzene + x 2 benzene + (1 − x 1 − x 2 ) 1-chlorohexane} have been determined at the temperature of 298.15 K and atmospheric pressure. Values of excess molar enthalpies were measured using a Calvet microcalorimeter, and excess molar volumes were determined from the densities of the pure liquids and mixtures, using a vibrating-tube densimeter. The results were fitted by means of different variable degree polynomials. Smooth representations of the results are presented and used to construct constant contours of excess molar enthalpy and excess molar volume on Roozeboom diagrams. Several empirical expressions that have been suggested for use with parameters and predicting excess properties of ternary mixtures from the experimental binary data were tested

  4. Evaluation of Excess Heat Utilization in District Heating Systems by Implementing Levelized Cost of Excess Heat

    Directory of Open Access Journals (Sweden)

    Borna Doračić

    2018-03-01

    Full Text Available District heating plays a key role in achieving high primary energy savings and the reduction of the overall environmental impact of the energy sector. This was recently recognized by the European Commission, which emphasizes the importance of these systems, especially when integrated with renewable energy sources, like solar, biomass, geothermal, etc. On the other hand, high amounts of heat are currently being wasted in the industry sector, which causes low energy efficiency of these processes. This excess heat can be utilized and transported to the final customer by a distribution network. The main goal of this research was to calculate the potential for excess heat utilization in district heating systems by implementing the levelized cost of excess heat method. Additionally, this paper proves the economic and environmental benefits of switching from individual heating solutions to a district heating system. This was done by using the QGIS software. The variation of different relevant parameters was taken into account in the sensitivity analysis. Therefore, the final result was the determination of the maximum potential distance of the excess heat source from the demand, for different available heat supplies, costs of pipes, and excess heat prices.

  5. [Consumption of free sugars and excess weight in infants. A longitudinal study].

    Science.gov (United States)

    Jardí, Cristina; Aranda, Núria; Bedmar, Cristina; Ribot, Blanca; Elias, Irene; Aparicio, Estefania; Arija, Victoria

    2018-05-14

    The consumption of free sugars has been related to excess weight, with the WHO recommending an intake of <10% of total energy. The aim of this study is to assess the association between the consumption of free sugars at 12 months and the risk of excess weight at 30 months in healthy children. A longitudinal study was conducted on 81 children followed-up from birth to 30 months. A record was made of the clinical history and anthropometry, at birth, and at 12 and 30 months. Weight status was classified as with or without excess weight, according to WHO values. At 12 months, the intake of energy and nutrients was analysed by differentiating the intake of free and natural sugars. Multivariate analyses adjusted for the main confounding variables were performed. Free sugars were consumed by 40.4% of the 12-month-old children, being higher than that recommended, and being significantly higher in children with excess weight at 30 months (60.9%). The higher intake of free sugars at 12 months is associated with an increased risk of excess weight at 30 months (OR: 1.130, 95% CI: 1.032-1.238). The consumption of free sugars is much higher than that recommended in 12-month-old infants. This high intake could be a risk factor for excess weight, even at early ages. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  6. Androgen excess fetal programming of female reproduction: a developmental aetiology for polycystic ovary syndrome?

    Science.gov (United States)

    Abbott, D H; Barnett, D K; Bruns, C M; Dumesic, D A

    2005-01-01

    The aetiology of polycystic ovary syndrome (PCOS) remains unknown. This familial syndrome is prevalent among reproductive-aged women and its inheritance indicates a dominant regulatory gene with incomplete penetrance. However, promising candidate genes have proven unreliable as markers for the PCOS phenotype. This lack of genetic linkage may represent both extreme heterogeneity of PCOS and difficulty in establishing a universally accepted PCOS diagnosis. Nevertheless, hyperandrogenism is one of the most consistently expressed PCOS traits. Animal models that mimic fetal androgen excess may thus provide unique insight into the origins of the PCOS syndrome. Many female mammals exposed to androgen excess in utero or during early post-natal life typically show masculinized and defeminized behaviour, ovulatory dysfunction and virilized genitalia, although behavioural and ovulatory dysfunction can coexist without virilized genitalia based upon the timing of androgen excess. One animal model shows particular relevance to PCOS: the prenatally androgenized female rhesus monkey. Females exposed to androgen excess early in gestation exhibit hyperandrogenism, oligomenorrhoea and enlarged, polyfollicular ovaries, in addition to LH hypersecretion, impaired embryo development, insulin resistance accompanying abdominal obesity, impaired insulin response to glucose and hyperlipidaemia. Female monkeys exposed to androgen excess late in gestation mimic these programmed changes, except for LH and insulin secretion defects. In utero androgen excess may thus variably perturb multiple organ system programming and thereby provide a single, fetal origin for a heterogeneous adult syndrome.

  7. Nonintrusive verification attributes for excess fissile materials

    International Nuclear Information System (INIS)

    Nicholas, N.J.; Eccleston, G.W.; Fearey, B.L.

    1997-10-01

    Under US initiatives, over two hundred metric tons of fissile materials have been declared to be excess to national defense needs. These excess materials are in both classified and unclassified forms. The US has expressed the intent to place these materials under international inspections as soon as practicable. To support these commitments, members of the US technical community are examining a variety of nonintrusive approaches (i.e., those that would not reveal classified or sensitive information) for verification of a range of potential declarations for these classified and unclassified materials. The most troublesome and potentially difficult issues involve approaches for international inspection of classified materials. The primary focus of the work to date has been on the measurement of signatures of relevant materials attributes (e.g., element, identification number, isotopic ratios, etc.), especially those related to classified materials and items. The authors are examining potential attributes and related measurement technologies in the context of possible verification approaches. The paper will discuss the current status of these activities, including their development, assessment, and benchmarking status

  8. Preferential solvation: dividing surface vs excess numbers.

    Science.gov (United States)

    Shimizu, Seishi; Matubayasi, Nobuyuki

    2014-04-10

    How do osmolytes affect the conformation and configuration of supramolecular assembly, such as ion channel opening and actin polymerization? The key to the answer lies in the excess solvation numbers of water and osmolyte molecules; these numbers are determinable solely from experimental data, as guaranteed by the phase rule, as we show through the exact solution theory of Kirkwood and Buff (KB). The osmotic stress technique (OST), in contrast, purposes to yield alternative hydration numbers through the use of the dividing surface borrowed from the adsorption theory. However, we show (i) OST is equivalent, when it becomes exact, to the crowding effect in which the osmolyte exclusion dominates over hydration; (ii) crowding is not the universal driving force of the osmolyte effect (e.g., actin polymerization); (iii) the dividing surface for solvation is useful only for crowding, unlike in the adsorption theory which necessitates its use due to the phase rule. KB thus clarifies the true meaning and limitations of the older perspectives on preferential solvation (such as solvent binding models, crowding, and OST), and enables excess number determination without any further assumptions.

  9. [Disability attributable to excess weight in Spain].

    Science.gov (United States)

    Martín-Ramiro, José Javier; Alvarez-Martín, Elena; Gil-Prieto, Ruth

    2014-08-19

    To estimate the disability attributable to higher than optimal body mass index in the Spanish population in 2006. Excess body weight prevalence data were obtained from the 2006 National Health Survey (NHS), while the prevalence of associated morbidities was extracted from the 2006 NHS and from a national hospital data base. Population attributable fractions were applied and disability attributable was expressed as years life with disability (YLD). In 2006, in the Spanish population aged 35-79 years, 791.650 YLD were lost due to higher than optimal body mass index (46.7% in males and 53.3% in females). Overweight (body mass index 25-29.9) accounted for 45.7% of total YLD. Males YLD were higher than females under 60. The 35-39 quinquennial group showed a difference for males of 16.6% while in the 74-79 group the difference was 23.8% for women. Osteoarthritis and chronic back pain accounted for 60% of YLD while hypertensive disease and type 2 diabetes mellitus were responsible of 37%. Excess body weight is a health risk related to the development of various diseases with an important associated disability burden and social and economical cost. YLD analysis is a useful monitor tool for disease control interventions. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  10. Control rod excess withdrawal prevention device

    International Nuclear Information System (INIS)

    Takayama, Yoshihito.

    1992-01-01

    Excess withdrawal of a control rod of a BWR type reactor is prevented. That is, the device comprises (1) a speed detector for detecting the driving speed of a control rod, (2) a judging circuit for outputting an abnormal signal if the driving speed is greater than a predetermined level and (3) a direction control valve compulsory closing circuit for controlling the driving direction of inserting and withdrawing a control rod based on an abnormal signal. With such a constitution, when the with drawing speed of a control rod is greater than a predetermined level, it is detected by the speed detector and the judging circuit. Then, all of the direction control valve are closed by way of the direction control valve compulsory closing circuit. As a result, the operation of the control rod is stopped compulsorily and the withdrawing speed of the control rod can be lowered to a speed corresponding to that upon gravitational withdrawal. Accordingly, excess withdrawal can be prevented. (I.S)

  11. Total-body sodium and sodium excess

    International Nuclear Information System (INIS)

    Aloia, J.F.; Cohn, S.H.; Abesamis, C.; Babu, T.; Zanzi, I.; Ellis, K.

    1980-01-01

    Total-body levels of sodium (TBNa), chlorine (TBCI), calcium (TBCa), and potassium (TBK) were measured by neutron activation and analysis of results by whole body counting in 66 postmenopausal women. The relationship between TBNa, and TBCl, TBK, and TBCa on the one hand, and height and weight on the other, were found to compare with those previously reported. The hypothesis that TBNa and TBCl are distributed normally could not be rejected. The sodium excess (Na/sub es/) is defined as the sodium that is present in excess of that associated with the extracellular fluid (chlorine) space; the Na/sub es/ approximates nonexchangeable bone sodium. In these 66 postmenopausal women, and in patients with different endocrinopathies previously described, the values on Na/sub es/ did not differ from the normal values except in the thyrotoxicosis patients, where they were decreased. A close relationship between Na/sub es/ and TBCa was maintained in the endocrinopathies studied. This relationship was found in conditions accompanied by either an increment or a loss of skeletal mass. It appears that the NA/sub es/ value is primarily dependent upon the calcium content of bone

  12. [Association between hours of television watched, physical activity, sleep and excess weight among young adults].

    Science.gov (United States)

    Martínez-Moyá, María; Navarrete-Muñoz, Eva M; García de la Hera, Manuela; Giménez-Monzo, Daniel; González-Palacios, Sandra; Valera-Gran, Desirée; Sempere-Orts, María; Vioque, Jesús

    2014-01-01

    To explore the association between excess weight or body mass index (BMI) and the time spent watching television, self-reported physical activity and sleep duration in a young adult population. We analyzed cross-sectional baseline data of 1,135 participants (17-35 years old) from the project Dieta, salud y antropometría en población universitaria (Diet, Health and Anthrompmetric Variables in Univeristy Students). Information about time spent watching television, sleep duration, self-reported physical activity and self-reported height and weight was provided by a baseline questionnaire. BMI was calculated as kg/m(2) and excess of weight was defined as ≥25. We used multiple logistic regression to explore the association between excess weight (no/yes) and independent variables, and multiple linear regression for BMI. The prevalence of excess weight was 13.7% (11.2% were overweight and 2.5% were obese). A significant positive association was found between excess weight and a greater amount of time spent watching television. Participants who reported watching television >2h a day had a higher risk of excess weight than those who watched television ≤1h a day (OR=2.13; 95%CI: 1.37-3.36; p-trend: 0.002). A lower level of physical activity was associated with an increased risk of excess weight, although the association was statistically significant only in multiple linear regression (p=0.037). No association was observed with sleep duration. A greater number of hours spent watching television and lower physical activity were significantly associated with a higher BMI in young adults. Both factors are potentially modifiable with preventive strategies. Copyright © 2013 SESPAS. Published by Elsevier Espana. All rights reserved.

  13. Effect of changing from the National Health and Nutritional Examination Survey III spirometry reference range to that of the Global Lung Initiative 2012 at Gold Coast Hospital and Health Service.

    Science.gov (United States)

    Embling, Laura A K; Zagami, Debbie; Sriram, Krishna Bajee; Gordon, Robert J; Sivakumaran, Pathmanathan

    2016-12-01

    The categorisation of lung disease into obstructive ventilatory defect (OVD) and tendency to a restrictive ventilatory defect (TRVD) patterns using spirometry is used to guide both prognostication and treatment. The effectiveness of categorisation depends upon having reference ranges that accurately represent the population they describe. The Global Lung Initiative 2012 (GLI 2012) has spirometry reference ranges drawn from the largest sample size to date. This study aimed to determine whether using spirometry reference ranges from the new GLI 2012 dataset, compared to the previously used National Health and Nutritional Examination Survey III (NHANES III) dataset, resulted in a change in diagnosis between OVD, TRVD and normal ventilatory pattern (NVP). Spirometry data were collected from 301 patients, aged 18-80 years, undergoing investigation at the Gold Coast Hospital and Health Service (GCHHS) throughout February and March 2014. OVD was defined as a forced expiratory volume in 1 second (FEV 1 ) divided by forced vital capacity (FVC) less than lower limit of normal (LLN). TRVD was defined as FEV 1 /FVC ≥ LLN, FEV 1 reference range resulted in a change in diagnosis of lung disease in 5.9% of the individuals included in this study. This variance in diagnosis when changing reference ranges should be taken into account by clinicians as it may affect patient management.

  14. Molecular simulation of excess isotherm and excess enthalpy change in gas-phase adsorption.

    Science.gov (United States)

    Do, D D; Do, H D; Nicholson, D

    2009-01-29

    We present a new approach to calculating excess isotherm and differential enthalpy of adsorption on surfaces or in confined spaces by the Monte Carlo molecular simulation method. The approach is very general and, most importantly, is unambiguous in its application to any configuration of solid structure (crystalline, graphite layer or disordered porous glass), to any type of fluid (simple or complex molecule), and to any operating conditions (subcritical or supercritical). The behavior of the adsorbed phase is studied using the partial molar energy of the simulation box. However, to characterize adsorption for comparison with experimental data, the isotherm is best described by the excess amount, and the enthalpy of adsorption is defined as the change in the total enthalpy of the simulation box with the change in the excess amount, keeping the total number (gas + adsorbed phases) constant. The excess quantities (capacity and energy) require a choice of a reference gaseous phase, which is defined as the adsorptive gas phase occupying the accessible volume and having a density equal to the bulk gas density. The accessible volume is defined as the mean volume space accessible to the center of mass of the adsorbate under consideration. With this choice, the excess isotherm passes through a maximum but always remains positive. This is in stark contrast to the literature where helium void volume is used (which is always greater than the accessible volume) and the resulting excess can be negative. Our definition of enthalpy change is equivalent to the difference between the partial molar enthalpy of the gas phase and the partial molar enthalpy of the adsorbed phase. There is no need to assume ideal gas or negligible molar volume of the adsorbed phase as is traditionally done in the literature. We illustrate this new approach with adsorption of argon, nitrogen, and carbon dioxide under subcritical and supercritical conditions.

  15. The predictive value of preoperative perfusion/ventilation scintigraphy, spirometry and x-ray of the lungs on postoperative pulmonary complications. A prospective study

    International Nuclear Information System (INIS)

    Fogh, J.; Wille-Joergensen, P.; Brynjolf, I.; Thorup, J.; Joergensen, T.; Bording, L.; Kjaergaard, J.

    1987-01-01

    Prospectively, 125 patients were examined with 99m Tc-perfusion scintigraphy, 89m Kr- or 127 Xe-ventilation scintigraphy and chest radiogram prior to major surgery. Postoperative therapy-demanding pulmonary complications occurred in 18% of the patients. A statistical association could be demonstrated between all the preoperative tests except ventilation scintigraphy and the frequency of complications. However, the predictive values of each of the tests, or even the combined results, were not significantly different from the frequency of complications among all the patients. It is concluded that the predictive values of perfusion-and ventilation scintigraphy, spirometry and radiogram of the chest are too low to be of any practical use. (author)

  16. Association between spirometry controlled chest CT scores using computer-animated biofeedback and clinical markers of lung disease in children with cystic fibrosis

    DEFF Research Database (Denmark)

    Kongstad, Thomas; Green, Kent; Buchvald, Frederik

    2017-01-01

    Background: Computed tomography (CT) of the lungs is the gold standard for assessing the extent of structural changes in the lungs. Spirometry-controlled chest CT (SCCCT) has improved the usefulness of CT by standardising inspiratory and expiratory lung volumes during imaging. This was a single...... (expressed as % of maximum score) to quantify different aspects of structural lung changes including bronchiectasis, airway wall thickening, mucus plugging, opacities, cysts, bullae and gas trapping. Clinical markers consisted of outcomes from pulmonary function tests, microbiological cultures from sputum......-centre cross-sectional study in children with cystic fibrosis (CF). Using SCCCT we wished to investigate the association between the quantity and extent of structural lung changes and pulmonary function outcomes, and prevalence of known CF lung pathogens. Methods: CT images were analysed by CF-CT scoring...

  17. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    Science.gov (United States)

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  18. 31 CFR 353.12 - Disposition of excess.

    Science.gov (United States)

    2010-07-01

    ... necessary to adjust the excess. Instructions for adjustment of the excess can be obtained by email at [email protected] or by writing to Bureau of the Public Debt, Parkersburg, WV 26106-1328. [68 FR 24805...

  19. Iodine Excess is a Risk Factor for Goiter Formation

    African Journals Online (AJOL)

    Key Words: Iodine excess, Goiter, Sub Saharan Africa. Iodine Excess is a ... synthesis leading to increased thyroid stimulating hormone ..... study done in Uganda revealed a similar picture ... significant association, probably due to recall bias.

  20. Production of ethanol from excess ethylene

    DEFF Research Database (Denmark)

    Kadhim, Adam S.; Carlsen, Kim B.; Bisgaard, Thomas

    2012-01-01

    will focus on the synthetic method, which employs direct hydration of ethylene. A conceptual process design of an ethyl alcohol producing plant is performed in a MSc-level course on Process Design at the Department of Chemical and Biochemical Engineering at DTU. In the designed process, 190 proof ethyl...... alcohol (azeotropic mixture) is produced from excess ethylene containing propylene and methane as impurities. The design work is based on a systematic approach consisting of 12 tasks performed in a specified hierarchy. According to this 12-tasks design procedure, information about the product and process...... of the designed process. The resulting design utilizes 75 million kg/year ethylene feed in order to obtain an ethyl alcohol production of 90.5 million kg/year. The total capital investment has been estimated to 43 million USD and the total product cost without depreciation estimated to 58.5 million USD...

  1. Excessive Fragmentary Myoclonus: What Do We Know?

    Directory of Open Access Journals (Sweden)

    Jiří Nepožitek

    2017-03-01

    Full Text Available Excessive fragmentary myoclonus (EFM is a polysomnographic finding registered by the surface electromyography (EMG and characterized as a result of the muscle activity consisting of sudden, isolated, arrhythmic, asynchronous and asymmetric brief twitches. The EMG potentials are defined by the exact criteria in The International Classification of the Sleep Disorders, 3rd edition and they appear with high intensity in all sleep stages. Clinical significance of EFM is unclear. It was observed in combination with other diseases and features such as obstructive and central sleep apnea, narcolepsy, periodic limb movements, insomnia, neurodegenerative disorders and peripheral nerve dysfunction. Relation to such wide range of diseases supports the opinion that EFM is nor a specific sleep disorder nor a specific polysomnographic sign. The option that EFM is a normal variant has also not been ruled out so far.

  2. Di-photon excess illuminates dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Backović, Mihailo [Center for Cosmology, Particle Physics and Phenomenology - CP3,Universite Catholique de Louvain, Louvain-la-neuve (Belgium); Mariotti, Alberto [Theoretische Natuurkunde and IIHE/ELEM, Vrije Universiteit Brussel,Pleinlaan 2, B-1050 Brussels (Belgium); International Solvay Institutes,Pleinlaan 2, B-1050 Brussels (Belgium); Redigolo, Diego [Laboratoire de Physique Théorique et Hautes Energies, CNRS UMR 7589,Universiteé Pierre et Marie Curie, 4 place Jussieu, F-75005, Paris (France)

    2016-03-22

    We propose a simplified model of dark matter with a scalar mediator to accommodate the di-photon excess recently observed by the ATLAS and CMS collaborations. Decays of the resonance into dark matter can easily account for a relatively large width of the scalar resonance, while the magnitude of the total width combined with the constraint on dark matter relic density leads to sharp predictions on the parameters of the Dark Sector. Under the assumption of a rather large width, the model predicts a signal consistent with ∼300 GeV dark matter particle and ∼750 GeV scalar mediator in channels with large missing energy. This prediction is not yet severely bounded by LHC Run I searches and will be accessible at the LHC Run II in the jet plus missing energy channel with more luminosity. Our analysis also considers astro-physical constraints, pointing out that future direct detection experiments will be sensitive to this scenario.

  3. Di-photon excess illuminates dark matter

    International Nuclear Information System (INIS)

    Backović, Mihailo; Mariotti, Alberto; Redigolo, Diego

    2016-01-01

    We propose a simplified model of dark matter with a scalar mediator to accommodate the di-photon excess recently observed by the ATLAS and CMS collaborations. Decays of the resonance into dark matter can easily account for a relatively large width of the scalar resonance, while the magnitude of the total width combined with the constraint on dark matter relic density leads to sharp predictions on the parameters of the Dark Sector. Under the assumption of a rather large width, the model predicts a signal consistent with ∼300 GeV dark matter particle and ∼750 GeV scalar mediator in channels with large missing energy. This prediction is not yet severely bounded by LHC Run I searches and will be accessible at the LHC Run II in the jet plus missing energy channel with more luminosity. Our analysis also considers astro-physical constraints, pointing out that future direct detection experiments will be sensitive to this scenario.

  4. Excess plutonium disposition using ALWR technology

    International Nuclear Information System (INIS)

    Phillips, A.; Buckner, M.R.; Radder, J.A.; Angelos, J.G.; Inhaber, H.

    1993-02-01

    The Office of Nuclear Energy of the Department of Energy chartered the Plutonium Disposition Task Force in August 1992. The Task Force was created to assess the range of practicable means of disposition of excess weapons-grade plutonium. Within the Task Force, working groups were formed to consider: (1) storage, (2) disposal,and(3) fission options for this disposition,and a separate group to evaluate nonproliferation concerns of each of the alternatives. As a member of the Fission Working Group, the Savannah River Technology Center acted as a sponsor for light water reactor (LWR) technology. The information contained in this report details the submittal that was made to the Fission Working Group of the technical assessment of LWR technology for plutonium disposition. The following aspects were considered: (1) proliferation issues, (2) technical feasibility, (3) technical availability, (4) economics, (5) regulatory issues, and (6) political acceptance

  5. Propylene Glycol Poisoning From Excess Whiskey Ingestion

    Directory of Open Access Journals (Sweden)

    Courtney A. Cunningham MD

    2015-09-01

    Full Text Available In this report, we describe a case of high anion gap metabolic acidosis with a significant osmolal gap attributed to the ingestion of liquor containing propylene glycol. Recently, several reports have characterized severe lactic acidosis occurring in the setting of iatrogenic unintentional overdosing of medications that use propylene glycol as a diluent, including lorazepam and diazepam. To date, no studies have explored potential effects of excess propylene glycol in the setting of alcohol intoxication. Our patient endorsed drinking large volumes of cinnamon flavored whiskey, which was likely Fireball Cinnamon Whisky. To our knowledge, this is the first case of propylene glycol toxicity from an intentional ingestion of liquor containing propylene glycol.

  6. Origin of Tungsten Excess in Komatiites

    Science.gov (United States)

    Becker, H.; Brandon, A. D.; Walker, R. J.

    2004-12-01

    The limited database available for W abundances in komatiites (n=7, Newsom et al., 1996) suggests that when melting and fractional crystallization effects are filtered out, these komatiites have about 10 times higher W, compared to other mantle-derived mafic-ultramafic magmas (MORB, OIB). The excess of W in the komatiites relative to lithophile highly incompatible elements becomes obvious when compared with the low concentrations of the light REE Ce and Nd (about 1-2 ug/g in many komatiites, compared to > 10 ug/g in most MORB and OIB). In order to increase the komatiite W database, komatiite samples from Phanerozoic (Gorgona Island) and Archean terraines (Boston Creek/Canada, Belingwe/South Africa, 2.7 Ga) were dissolved and W was separated in order to obtain W concentrations by isotope dilution. Except for one sample from Gorgona Island with low W (23 ng/g), samples from all three locales show high W (516 to 2643 ng/g), with most samples containing near 700 ng/g W. Three Hawaiian picrites (H23, LO-02-04, MK-1-6) were also analyzed for comparative purposes and contain 75, 163 and 418 ng/g W, respectively. The W concentrations in the Hawaiian picrites are comparable or lower than W concentrations in Hawaiian tholeiites (Newsom et al., 1996). Mass balance considerations suggest that it is unlikely that the W excess in komatiites reflects W contributions to the mantle sources of komatiites from the outer core. The W enrichment could result from shallow-level alteration processes if primary W abundances of komatiites were low and W was added via fluids, containing W and other fluid-mobile elements derived from crustal rocks. Because most W in such samples would be of crustal origin, small contributions from the outer core may be difficult to detect using 182W systematics (Schersten et al., 2003).

  7. Vitamin paradox in obesity: Deficiency or excess?

    Science.gov (United States)

    Zhou, Shi-Sheng; Li, Da; Chen, Na-Na; Zhou, Yiming

    2015-08-25

    Since synthetic vitamins were used to fortify food and as supplements in the late 1930s, vitamin intake has significantly increased. This has been accompanied by an increased prevalence of obesity, a condition associated with diabetes, hypertension, cardiovascular disease, asthma and cancer. Paradoxically, obesity is often associated with low levels of fasting serum vitamins, such as folate and vitamin D. Recent studies on folic acid fortification have revealed another paradoxical phenomenon: obesity exhibits low fasting serum but high erythrocyte folate concentrations, with high levels of serum folate oxidation products. High erythrocyte folate status is known to reflect long-term excess folic acid intake, while increased folate oxidation products suggest an increased folate degradation because obesity shows an increased activity of cytochrome P450 2E1, a monooxygenase enzyme that can use folic acid as a substrate. There is also evidence that obesity increases niacin degradation, manifested by increased activity/expression of niacin-degrading enzymes and high levels of niacin metabolites. Moreover, obesity most commonly occurs in those with a low excretory reserve capacity (e.g., due to low birth weight/preterm birth) and/or a low sweat gland activity (black race and physical inactivity). These lines of evidence raise the possibility that low fasting serum vitamin status in obesity may be a compensatory response to chronic excess vitamin intake, rather than vitamin deficiency, and that obesity could be one of the manifestations of chronic vitamin poisoning. In this article, we discuss vitamin paradox in obesity from the perspective of vitamin homeostasis.

  8. Tracking atmospheric boundary layer dynamics with water vapor D-excess observations

    KAUST Repository

    Parkes, Stephen

    2015-04-01

    was associated with high radon concentrations and low D-excess. Interestingly the intermittent turbulence that brought low radon air to the surface from above the stable surface layer was associated with increases in the D-excess. These observations have shown that the D-excess in water vapor can be used to study moisture variability associated with atmospheric boundary layer dynamics on diurnal time scales. However, without knowledge of all isotopic end members, it is difficult to quantify the sources of moisture.

  9. Excessive anticoagulation with warfarin or phenprocoumon may have multiple causes

    DEFF Research Database (Denmark)

    Meegaard, Peter Martin; Holck, Line H V; Pottegård, Anton

    2012-01-01

    Excessive anticoagulation with vitamin K antagonists is a serious condition with a substantial risk of an adverse outcome. We thus found it of interest to review a large case series to characterize the underlying causes of excessive anticoagulation.......Excessive anticoagulation with vitamin K antagonists is a serious condition with a substantial risk of an adverse outcome. We thus found it of interest to review a large case series to characterize the underlying causes of excessive anticoagulation....

  10. Excessive Testing and Pupils in the Public Schools

    Science.gov (United States)

    Ediger, Marlow

    2017-01-01

    This article explores the question of excessive testing in public schools, its value in the educational process, and the impact that excessive testing may have on the student and the family unit. While assessments are valuable when used properly, excessive testing may lead to problems with unforeseen consequences.

  11. Pulsating variables

    International Nuclear Information System (INIS)

    1989-01-01

    The study of stellar pulsations is a major route to the understanding of stellar structure and evolution. At the South African Astronomical Observatory (SAAO) the following stellar pulsation studies were undertaken: rapidly oscillating Ap stars; solar-like oscillations in stars; 8-Scuti type variability in a classical Am star; Beta Cephei variables; a pulsating white dwarf and its companion; RR Lyrae variables and galactic Cepheids. 4 figs

  12. Effects of ultrasonic disintegration of excess sewage sludge.

    Science.gov (United States)

    Zielewicz, Ewa

    2016-10-01

    Breaking down sludge floc (sonodyspergation effect) and destruction of the cell membranes of microorganisms forming floc is a direct effect of ultrasonic disintegration of sludge excess. This results in release of organic material by liquid sludge (the sonolysis effect). Desired technological effects of the disintegration are: to shorten the hydrolytic phase of fermentation, to increase the production of biogas (source of renewable energy) and an increased mineralization (stability) of fermented sludge. The presented study demonstrates research covering thickened excess sludge of various physicochemical properties, collected from nine municipal sewage treatment plants. The sludge was subjected to ultrasonic disintegration using three differently constructed disintegrators and different proportions of sonification area. Direct effects of disintegration were monitored and recorded using selected indicators describing changes in the properties of sludge and increase of substance dispersed and dissolved in the supernatant liquid to be filtered. Studies have demonstrated that those (direct) effects of ultrasonic disintegration depend on the physicochemical properties of the sludge (foremost the concentration of dry solids) that determine their variable susceptibility to the disintegration methods. The direct effects also depend on optimal process conditions (which consist of the construction of the ultrasonic disintegrator), the geometric proportions of the sonication area and the operating parameters of disintegration (which could be appropriately matched to the characteristics of sludge). The most preferable results were obtained for ultrasonic disintegration of sludge with a dry matter concentration C 0 < 4.2 %. The highest effect of sonolysis-an almost 30-fold increase in the COD dissolved in the supernatant-was obtained for the sludge of lowest dry matter (C 0 = 2.0 %), which was sonicated in a reactor with a short transducer of the largest radiating surface

  13. A COMPREHENSIVE CENSUS OF NEARBY INFRARED EXCESS STARS

    Energy Technology Data Exchange (ETDEWEB)

    Cotten, Tara H.; Song, Inseok, E-mail: tara@physast.uga.edu, E-mail: song@physast.uga.edu [Department of Physics and Astronomy, University of Georgia, Athens, GA 30602 (United States)

    2016-07-01

    The conclusion of the Wide-Field Infrared Survey Explorer ( WISE ) mission presents an opportune time to summarize the history of using excess emission in the infrared as a tracer of circumstellar material and exploit all available data for future missions such as the James Webb Space Telescope . We have compiled a catalog of infrared excess stars from peer-reviewed articles and perform an extensive search for new infrared excess stars by cross-correlating the Tycho-2 and all-sky WISE (AllWISE) catalogs. We define a significance of excess in four spectral type divisions and select stars showing greater than either 3 σ or 5 σ significance of excess in the mid- and far-infrared. Through procedures including spectral energy distribution fitting and various image analyses, each potential excess source was rigorously vetted to eliminate false positives. The infrared excess stars from the literature and the new stars found through the Tycho-2 and AllWISE cross-correlation produced nearly 500 “Prime” infrared excess stars, of which 74 are new sources of excess, and >1200 are “Reserved” stars, of which 950 are new sources of excess. The main catalog of infrared excess stars are nearby, bright, and either demonstrate excess in more than one passband or have infrared spectroscopy confirming the infrared excess. This study identifies stars that display a spectral energy distribution suggestive of a secondary or post-protoplanetary generation of dust, and they are ideal targets for future optical and infrared imaging observations. The final catalogs of stars summarize the past work using infrared excess to detect dust disks, and with the most extensive compilation of infrared excess stars (∼1750) to date, we investigate various relationships among stellar and disk parameters.

  14. ATLAS Z Excess in Minimal Supersymmetric Standard Model

    International Nuclear Information System (INIS)

    Lu, Xiaochuan; Terada, Takahiro

    2015-06-01

    Recently the ATLAS collaboration reported a 3 sigma excess in the search for the events containing a dilepton pair from a Z boson and large missing transverse energy. Although the excess is not sufficiently significant yet, it is quite tempting to explain this excess by a well-motivated model beyond the standard model. In this paper we study a possibility of the minimal supersymmetric standard model (MSSM) for this excess. Especially, we focus on the MSSM spectrum where the sfermions are heavier than the gauginos and Higgsinos. We show that the excess can be explained by the reasonable MSSM mass spectrum.

  15. 75 FR 30846 - Monthly Report of Excess Income and Annual Report of Uses of Excess Income (Correction)

    Science.gov (United States)

    2010-06-02

    ... Income and Annual Report of Uses of Excess Income (Correction) AGENCY: Office of the Chief Information.... Project owners are permitted to retain Excess Income for projects under terms and conditions established by HUD. Owners must request to retain some or all of their Excess Income. The request must be...

  16. Energy potential of the modified excess sludge

    Directory of Open Access Journals (Sweden)

    Zawieja Iwona

    2017-01-01

    Full Text Available On the basis of the SCOD value of excess sludge it is possible to estimate an amount of energy potentially obtained during the methane fermentation process. Based on a literature review, it has been estimated that from 1 kg of SCOD it is possible to obtain 3.48 kWh of energy. Taking into account the above methane and energy ratio (i.e. 10 kWh/1Nm3 CH4, it is possible to determine the volume of methane obtained from the tested sludge. Determination of potential energy of sludge is necessary for the use of biogas as a source of power generators as cogeneration and ensure the stability of this type of system. Therefore, the aim of the study was to determine the energy potential of excess sludge subjected to the thermal and chemical disintegration. In the case of thermal disintegration, test was conducted in the low temperature 80°C. The reagent used for the chemical modification was a peracetic acid, which in an aqueous medium having strong oxidizing properties. The time of chemical modification was 6 hours. Applied dose of the reagent was 1.0 ml CH3COOOH/L of sludge. By subjecting the sludge disintegration by the test methods achieved an increase in the SCOD value of modified sludge, indicating the improvement of biodegradability along with a concomitant increase in their energy potential. The obtained experimental production of biogas from disintegrated sludge confirmed that it is possible to estimate potential intensity of its production. The SCOD value of 2576 mg O2/L, in the case of chemical disintegration, was obtained for a dose of 1.0 ml CH3COOH/L. For this dose the pH value was equal 6.85. In the case of thermal disintegration maximum SCOD value was 2246 mg O2/L obtained at 80°C and the time of preparation 6 h. It was estimated that in case of thermal disintegration as well as for the chemical disintegration for selected parameters, the potential energy for model digester of active volume of 5L was, respectively, 0.193 and 0,118 kWh.

  17. Energy potential of the modified excess sludge

    Science.gov (United States)

    Zawieja, Iwona

    2017-11-01

    On the basis of the SCOD value of excess sludge it is possible to estimate an amount of energy potentially obtained during the methane fermentation process. Based on a literature review, it has been estimated that from 1 kg of SCOD it is possible to obtain 3.48 kWh of energy. Taking into account the above methane and energy ratio (i.e. 10 kWh/1Nm3 CH4), it is possible to determine the volume of methane obtained from the tested sludge. Determination of potential energy of sludge is necessary for the use of biogas as a source of power generators as cogeneration and ensure the stability of this type of system. Therefore, the aim of the study was to determine the energy potential of excess sludge subjected to the thermal and chemical disintegration. In the case of thermal disintegration, test was conducted in the low temperature 80°C. The reagent used for the chemical modification was a peracetic acid, which in an aqueous medium having strong oxidizing properties. The time of chemical modification was 6 hours. Applied dose of the reagent was 1.0 ml CH3COOOH/L of sludge. By subjecting the sludge disintegration by the test methods achieved an increase in the SCOD value of modified sludge, indicating the improvement of biodegradability along with a concomitant increase in their energy potential. The obtained experimental production of biogas from disintegrated sludge confirmed that it is possible to estimate potential intensity of its production. The SCOD value of 2576 mg O2/L, in the case of chemical disintegration, was obtained for a dose of 1.0 ml CH3COOH/L. For this dose the pH value was equal 6.85. In the case of thermal disintegration maximum SCOD value was 2246 mg O2/L obtained at 80°C and the time of preparation 6 h. It was estimated that in case of thermal disintegration as well as for the chemical disintegration for selected parameters, the potential energy for model digester of active volume of 5L was, respectively, 0.193 and 0,118 kWh.

  18. Cognitive Variability

    Science.gov (United States)

    Siegler, Robert S.

    2007-01-01

    Children's thinking is highly variable at every level of analysis, from neural and associative levels to the level of strategies, theories, and other aspects of high-level cognition. This variability exists within people as well as between them; individual children often rely on different strategies or representations on closely related problems…

  19. Excess air in groundwater as a potential indicator of past environmental changes

    International Nuclear Information System (INIS)

    Aeschenbach-Hertig, W.; Beyerle, U.; Holocher, J.; Peeters, F.; Kipfer, R.

    2002-01-01

    Dissolved noble gases in groundwater are used to reconstruct paleotemperature, but also yield information about 'excess air', a component of dissolved gases in excess of solubility equilibrium, derived from dissolution of trapped air in the ground. A good characterization of the excess air component is necessary not only to obtain reliable noble gas temperatures, but also to investigate the potential of excess air as a proxy for past environmental conditions. Two excess air related quantities can be derived from groundwater noble gas data sets: The initial air/water ratio and the pressure exerted on the entrapped air. Under recharge conditions typical for many aquifers, the excess of dissolved gases, expressed by the relative Ne excess ΔNe, is mainly determined by the hydrostatic pressure on the entrapped air. Thus, we suggest that ΔNe is essentially a measure of the amplitude of water table fluctuations in the recharge area. Comparing data sets from three aquifers in temperate, humid latitudes and three aquifers in tropical, semi-arid regions, we find that ΔNe is generally higher in the tropical aquifers, possibly related to larger water table fluctuations in these aquifers characterized by deep unsaturated zones. Whereas ΔNe shows little temporal variation in the mid-latitude aquifers, there is a strong signal of higher ΔNe in the paleowaters of the tropical aquifers as compared to water recharged under modern climate conditions. This finding may indicate a higher variability of recharge in the past at the studied tropical sites. (author)

  20. Dark matter "transporting" mechanism explaining positron excesses

    Science.gov (United States)

    Kim, Doojin; Park, Jong-Chul; Shin, Seodong

    2018-04-01

    We propose a novel mechanism to explain the positron excesses, which are observed by satellite-based telescopes including PAMELA and AMS-02, in dark matter (DM) scenarios. The novelty behind the proposal is that it makes direct use of DM around the Galactic Center where DM populates most densely, allowing us to avoid tensions from cosmological and astrophysical measurements. The key ingredients of this mechanism include DM annihilation into unstable states with a very long laboratory-frame life time and their "retarded" decay near the Earth to electron-positron pair(s) possibly with other (in)visible particles. We argue that this sort of explanation is not in conflict with relevant constraints from big bang nucleosynthesis and cosmic microwave background. Regarding the resultant positron spectrum, we provide a generalized source term in the associated diffusion equation, which can be readily applicable to any type of two-"stage" DM scenarios wherein production of Standard Model particles occurs at completely different places from those of DM annihilation. We then conduct a data analysis with the recent AMS-02 data to validate our proposal.

  1. Medical Ethics and Protection from Excessive Radiation

    International Nuclear Information System (INIS)

    Ruzicka, I.

    1998-01-01

    Among artificial sources of ionic radiation people are most often exposed to those emanating from X-ray diagnostic equipment. However, responsible usage of X-ray diagnostic methods may considerably reduce the general exposure to radiation. A research on rational access to X-ray diagnostic methods conducted at the X-ray Cabinet of the Tresnjevka Health Center was followed by a control survey eight years later of the rational methods applied, which showed that the number of unnecessary diagnostic examining was reduced for 34 % and the diagnostic indications were 10-40 $ more precise. The results therefore proved that radiation problems were reduced accordingly. The measures applied consisted of additional training organized for health care workers and a better education of the population. The basic element was then the awareness of both health care workers and the patients that excessive radiation should be avoided. The condition for achieving this lies in the moral responsibility of protecting the patients' health. A radiologist, being the person that promotes and carries out this moral responsibility, should organize and hold continual additional training of medical doctors, as well as education for the patients, and apply modern equipment. The basis of such an approach should be established by implementing medical ethics at all medical schools and faculties, together with the promotion of a wider intellectual and moral integrity of each medical doctor. (author)

  2. Iron excess in recreational marathon runners.

    Science.gov (United States)

    Mettler, S; Zimmermann, M B

    2010-05-01

    Iron deficiency and anemia may impair athletic performance, and iron supplements are commonly consumed by athletes. However, iron overload should be avoided because of the possible long-term adverse health effects. We investigated the iron status of 170 male and female recreational runners participating in the Zürich marathon. Iron deficiency was defined either as a plasma ferritin (PF) concentration or =4.5 (functional iron deficiency). After excluding subjects with elevated C-reactive protein concentrations, iron overload was defined as PF >200 microg/l. Iron depletion was found in only 2 out of 127 men (1.6% of the male study population) and in 12 out of 43 (28.0%) women. Functional iron deficiency was found in 5 (3.9%) and 11 (25.5%) male and female athletes, respectively. Body iron stores, calculated from the sTfR/PF ratio, were significantly higher (Pmarathon runners. Median PF among males was 104 microg/l, and the upper limit of the PF distribution in males was 628 microg/l. Iron overload was found in 19 out of 127 (15.0%) men but only 2 out of 43 in women (4.7%). Gender (male sex), but not age, was a predictor of higher PF (Pperformance, our findings indicate excess body iron may be common in male recreational runners and suggest supplements should only be used if tests of iron status indicate deficiency.

  3. Excessive Neural Responses and Visual Discomfort

    Directory of Open Access Journals (Sweden)

    L O'Hare

    2014-08-01

    Full Text Available Spatially and temporally periodic patterns can look aversive to some individuals (Wilkins et al, 1984, Brain, 107, 989-1017, especially clinical populations such as migraine (Marcus and Soso, 1989, Arch Neurol., 46(10, 1129-32 epilepsy (Wilkins, Darby and Binnie, 1979, Brain, 102, 1-25. It has been suggested that this might be due to excessive neural responses (Juricevic, Land, Wilkins and Webster, 2010, Perception, 39(7, 884-899. Spatial frequency content has been shown to affect both relative and absolute discomfort judgements for spatially periodic riloid stimuli (Clark, O'Hare and Hibbard, 2013, Perception, ECVP Supp.; O'Hare, Clark and Hibbard, 2013, Perception ECVP Supplement. The current study investigated the possibility of whether neural correlates of visual discomfort from periodic stimuli could be measured using EEG. Stimuli were first matched for perceived contrast using a self adjustment task. EEG measurements were then obtained, alongside subjective discomfort judgements. Subjective discomfort judgements support those found previously, under various circumstances, indicating that spatial frequency plays a role in the perceived discomfort of periodic images. However, trends in EEG responses do not appear to have a straightforward relationship to subjective discomfort judgements.

  4. Complementary technologies for verification of excess plutonium

    International Nuclear Information System (INIS)

    Langner, D.G.; Nicholas, N.J.; Ensslin, N.; Fearey, B.L.; Mitchell, D.J.; Marlow, K.W.; Luke, S.J.; Gosnell, T.B.

    1998-01-01

    Three complementary measurement technologies have been identified as candidates for use in the verification of excess plutonium of weapons origin. These technologies: high-resolution gamma-ray spectroscopy, neutron multiplicity counting, and low-resolution gamma-ray spectroscopy, are mature, robust technologies. The high-resolution gamma-ray system, Pu-600, uses the 630--670 keV region of the emitted gamma-ray spectrum to determine the ratio of 240 Pu to 239 Pu. It is useful in verifying the presence of plutonium and the presence of weapons-grade plutonium. Neutron multiplicity counting is well suited for verifying that the plutonium is of a safeguardable quantity and is weapons-quality material, as opposed to residue or waste. In addition, multiplicity counting can independently verify the presence of plutonium by virtue of a measured neutron self-multiplication and can detect the presence of non-plutonium neutron sources. The low-resolution gamma-ray spectroscopic technique is a template method that can provide continuity of knowledge that an item that enters the a verification regime remains under the regime. In the initial verification of an item, multiple regions of the measured low-resolution spectrum form a unique, gamma-radiation-based template for the item that can be used for comparison in subsequent verifications. In this paper the authors discuss these technologies as they relate to the different attributes that could be used in a verification regime

  5. Cool WISPs for stellar cooling excesses

    Energy Technology Data Exchange (ETDEWEB)

    Giannotti, Maurizio [Physical Sciences, Barry University, 11300 NE 2nd Avenue, Miami Shores, FL 33161 (United States); Irastorza, Igor; Redondo, Javier [Departamento de Física Teórica, Universidad de Zaragoza, Pedro Cerbuna 12, E-50009, Zaragoza, España (Spain); Ringwald, Andreas, E-mail: mgiannotti@barry.edu, E-mail: igor.irastorza@cern.ch, E-mail: jredondo@unizar.es, E-mail: andreas.ringwald@desy.de [Theory group, Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, D-22607 Hamburg (Germany)

    2016-05-01

    Several stellar systems (white dwarfs, red giants, horizontal branch stars and possibly the neutron star in the supernova remnant Cassiopeia A) show a mild preference for a non-standard cooling mechanism when compared with theoretical models. This exotic cooling could be provided by Weakly Interacting Slim Particles (WISPs), produced in the hot cores and abandoning the star unimpeded, contributing directly to the energy loss. Taken individually, these excesses do not show a strong statistical weight. However, if one mechanism could consistently explain several of them, the hint could be significant. We analyze the hints in terms of neutrino anomalous magnetic moments, minicharged particles, hidden photons and axion-like particles (ALPs). Among them, the ALP or a massless HP represent the best solution. Interestingly, the hinted ALP parameter space is accessible to the next generation proposed ALP searches, such as ALPS II and IAXO and the massless HP requires a multi TeV energy scale of new physics that might be accessible at the LHC.

  6. Cool WISPs for stellar cooling excesses

    International Nuclear Information System (INIS)

    Giannotti, Maurizio; Irastorza, Igor; Redondo, Javier; Ringwald, Andreas

    2016-01-01

    Several stellar systems (white dwarfs, red giants, horizontal branch stars and possibly the neutron star in the supernova remnant Cassiopeia A) show a mild preference for a non-standard cooling mechanism when compared with theoretical models. This exotic cooling could be provided by Weakly Interacting Slim Particles (WISPs), produced in the hot cores and abandoning the star unimpeded, contributing directly to the energy loss. Taken individually, these excesses do not show a strong statistical weight. However, if one mechanism could consistently explain several of them, the hint could be significant. We analyze the hints in terms of neutrino anomalous magnetic moments, minicharged particles, hidden photons and axion-like particles (ALPs). Among them, the ALP or a massless HP represent the best solution. Interestingly, the hinted ALP parameter space is accessible to the next generation proposed ALP searches, such as ALPS II and IAXO and the massless HP requires a multi TeV energy scale of new physics that might be accessible at the LHC.

  7. Excessive Additive Effect On Engine Oil Viscosity

    Directory of Open Access Journals (Sweden)

    Vojtěch Kumbár

    2014-01-01

    Full Text Available The main goal of this paper is excessive additive (for oil filling effect on engine oil dynamic viscosity. Research is focused to commercially distribute automotive engine oil with viscosity class 15W–40 designed for vans. There were prepared blends of new and used engine oil without and with oil additive in specific ratio according manufacturer’s recommendations. Dynamic viscosity of blends with additive was compared with pure new and pure used engine oil. The temperature dependence dynamic viscosity of samples was evaluated by using rotary viscometer with standard spindle. Concern was that the oil additive can moves engine oil of several viscosity grades up. It is able to lead to failure in the engine. Mathematical models were used for fitting experimental values of dynamic viscosity. Exponential fit function was selected, which was very accurate because the coefficient of determination R2 achieved high values (0.98–0.99. These models are able to predict viscosity behaviour blends of engine oil and additive.

  8. Cryolipolysis for reduction of excess adipose tissue.

    Science.gov (United States)

    Nelson, Andrew A; Wasserman, Daniel; Avram, Mathew M

    2009-12-01

    Controlled cold exposure has long been reported to be a cause of panniculitis in cases such as popsicle panniculitis. Cryolipolysis is a new technology that uses cold exposure, or energy extraction, to result in localized panniculitis and modulation of fat. Presently, the Zeltiq cryolipolysis device is FDA cleared for skin cooling, as well as various other indications, but not for lipolysis. There is, however, a pending premarket notification for noninvasive fat layer reduction. Initial animal and human studies have demonstrated significant reductions in the superficial fat layer thickness, ranging from 20% to 80%, following a single cryolipolysis treatment. The decrease in fat thickness occurs gradually over the first 3 months following treatment, and is most pronounced in patients with limited, discrete fat bulges. Erythema of the skin, bruising, and temporary numbness at the treatment site are commonly observed following treatment with the device, though these effects largely resolve in approximately 1 week. To date, there have been no reports of scarring, ulceration, or alterations in blood lipid or liver function profiles. Cryolipolysis is a new, noninvasive treatment option that may be of benefit in the treatment of excess adipose tissue.

  9. Di-photon excess at LHC and the gamma ray excess at the Galactic Centre

    Energy Technology Data Exchange (ETDEWEB)

    Hektor, Andi [National Institute of Chemical Physics and Biophysics,Rävala pst. 10, 10143 Tallinn (Estonia); Marzola, Luca [National Institute of Chemical Physics and Biophysics,Rävala pst. 10, 10143 Tallinn (Estonia); Institute of Physics, University of Tartu,Ravila 14c, 50411 Tartu (Estonia)

    2016-07-25

    Motivated by the recent indications for a 750 GeV resonance in the di-photon final state at the LHC, in this work we analyse the compatibility of the excess with the broad photon excess detected at the Galactic Centre. Intriguingly, by analysing the parameter space of an effective models where a 750 GeV pseudoscalar particles mediates the interaction between the Standard Model and a scalar dark sector, we prove the compatibility of the two signals. We show, however, that the LHC mono-jet searches and the Fermi LAT measurements strongly limit the viable parameter space. We comment on the possible impact of cosmic antiproton flux measurement by the AMS-02 experiment.

  10. Dynamics of the G-excess illusion

    Science.gov (United States)

    Baylor, K. A.; Reschke, M.; Guedry, F. E.; Mcgrath, B. J.; Rupert, A. H.

    1992-01-01

    The G-excess illusion is increasingly recognized as a cause of aviation mishaps especially when pilots perform high-speed, steeply banked turns at low altitudes. Centrifuge studies of this illusion have examined the perception of subject orientation and/or target displacement during maintained hypergravity with the subject's head held stationary. The transient illusory perceptions produced by moving the head in hypergravity are difficult to study onboard centrifuges because the high angular velocity ensures the presence of strong Coriolis cross-coupled semicircular canal effects that mask immediate transient otolith-organ effects. The present study reports perceptions following head movements in hypergravity produced by high-speed aircraft maintaining a banked attitude with low angular velocity to minimize cross-coupled effects. Methods: Fourteen subjects flew on the NASA KC-135 and were exposed to resultant gravity forces of 1.3, 1.5, and 1.8 G for 3 minute periods. On command, seated subjects made controlled head movements in roll, pitch, and yaw at 30 second intervals both in the dark and with faint targets at a distance of 5 feet. Results: head movement produced transient perception of target displacement and velocity at levels as low as 1.3 G. Reports of target velocity without appropriate corresponding displacement were common. At 1.8 G when yaw head movements were made from a face down position, 4 subjects reported oscillatory rotational target displacement with fast and slow alternating components suggestive of torsional nystagmus. Head movements evoked symptoms of nausea in most subjects, with 2 subjects and 1 observer vomiting. Conclusions: The transient percepts present conflicting signals, which introduced confusion in target and subject orientation. Repeated head movements in hypergravity generate nausea by mechanisms distinct from cross-coupled Coriolis effects.

  11. Millisecond Pulsars and the Galactic Center Excess

    Science.gov (United States)

    Gonthier, Peter L.; Koh, Yew-Meng; Kust Harding, Alice; Ferrara, Elizabeth C.

    2017-08-01

    Various groups including the Fermi team have confirmed the spectrum of the gamma- ray excess in the Galactic Center (GCE). While some authors interpret the GCE as evidence for the annihilation of dark matter (DM), others have pointed out that the GCE spectrum is nearly identical to the average spectrum of Fermi millisecond pul- sars (MSP). Assuming the Galactic Center (GC) is populated by a yet unobserved source of MSPs that has similar properties to that of MSPs in the Galactic Disk (GD), we present results of a population synthesis of MSPs from the GC. We establish parameters of various models implemented in the simulation code by matching characteristics of 54 detected Fermi MSPs in the first point source catalog and 92 detected radio MSPs in a select group of thirteen radio surveys and targeting a birth rate of 45 MSPs per mega-year. As a check of our simulation, we find excellent agreement with the estimated numbers of MSPs in eight globular clusters. In order to reproduce the gamma-ray spectrum of the GCE, we need to populate the GC with 10,000 MSPs having a Navarro-Frenk-White distribution suggested by the halo density of DM. It may be possible for Fermi to detect some of these MSPs in the near future; the simulation also predicts that many GC MSPs have radio fluxes S1400above 10 �μJy observable by future pointed radio observations. We express our gratitude for the generous support of the National Science Foundation (RUI: AST-1009731), Fermi Guest Investigator Program and the NASA Astrophysics Theory and Fundamental Program (NNX09AQ71G).

  12. Kinetic model of excess activated sludge thermohydrolysis.

    Science.gov (United States)

    Imbierowicz, Mirosław; Chacuk, Andrzej

    2012-11-01

    Thermal hydrolysis of excess activated sludge suspensions was carried at temperatures ranging from 423 K to 523 K and under pressure 0.2-4.0 MPa. Changes of total organic carbon (TOC) concentration in a solid and liquid phase were measured during these studies. At the temperature 423 K, after 2 h of the process, TOC concentration in the reaction mixture decreased by 15-18% of the initial value. At 473 K total organic carbon removal from activated sludge suspension increased to 30%. It was also found that the solubilisation of particulate organic matter strongly depended on the process temperature. At 423 K the transfer of TOC from solid particles into liquid phase after 1 h of the process reached 25% of the initial value, however, at the temperature of 523 K the conversion degree of 'solid' TOC attained 50% just after 15 min of the process. In the article a lumped kinetic model of the process of activated sludge thermohydrolysis has been proposed. It was assumed that during heating of the activated sludge suspension to a temperature in the range of 423-523 K two parallel reactions occurred. One, connected with thermal destruction of activated sludge particles, caused solubilisation of organic carbon and an increase of dissolved organic carbon concentration in the liquid phase (hydrolysate). The parallel reaction led to a new kind of unsolvable solid phase, which was further decomposed into gaseous products (CO(2)). The collected experimental data were used to identify unknown parameters of the model, i.e. activation energies and pre-exponential factors of elementary reactions. The mathematical model of activated sludge thermohydrolysis appropriately describes the kinetics of reactions occurring in the studied system. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Cardiovascular risk factors and events in women with androgen excess.

    Science.gov (United States)

    Macut, D; Antić, I B; Bjekić-Macut, J

    2015-03-01

    Androgen excess (AE) was approximated to be present in 7% of the adult population of women. Polycystic ovary syndrome (PCOS) is the most prevalent among them, followed by idiopathic hirsutism (IH), congenital adrenal hyperplasia (CAH), hyperandrogenic insulin-resistant acanthosis nigricans (HAIRAN) syndrome, and androgen-secreting neoplasms (ASNs). Increased cardiovascular risk was implicated in women with AE. Serum testosterone independently increases risk for cardiovascular disease (CVD), and correlates even with indices of subclinical atherosclerosis in various populations of postmenopausal women. Hyperandrogenism in PCOS is closely related to the aggravation of abdominal obesity, and together with insulin resistance forming the metabolic core for the development of CVD. However, phenotypic variability of PCOS generates significant influence on the cardiometabolic risks. Numerous risk factors in PCOS lead to 5-7 times higher risk for CVD and over 2-fold higher risk for coronary heart disease and stroke. However, issue on the cardiometabolic risk in postmenopausal women with hyperandrogenic history is still challenging. There is a significant overlapping in the CVD characteristics of women with PCOS and variants of CAH. Relevant clinical data on the prevalence and cardiometabolic risk and events in women with IH, HAIRAN syndrome or ASNs are scarce. The effects of various oral contraceptives (OCs) and antiandrogenic compounds on metabolic profile are varying, and could be related to the selected populations and different therapy regiments mainly conducted in women with PCOS. It is assumed relation of OCs containing antiandrogenic progestins to the increased risk of cardiovascular and thromboembolic events.

  14. Excess Weapons Plutonium Immobilization in Russia

    International Nuclear Information System (INIS)

    Jardine, L.; Borisov, G.B.

    2000-01-01

    The joint goal of the Russian work is to establish a full-scale plutonium immobilization facility at a Russian industrial site by 2005. To achieve this requires that the necessary engineering and technical basis be developed in these Russian projects and the needed Russian approvals be obtained to conduct industrial-scale immobilization of plutonium-containing materials at a Russian industrial site by the 2005 date. This meeting and future work will provide the basis for joint decisions. Supporting R and D projects are being carried out at Russian Institutes that directly support the technical needs of Russian industrial sites to immobilize plutonium-containing materials. Special R and D on plutonium materials is also being carried out to support excess weapons disposition in Russia and the US, including nonproliferation studies of plutonium recovery from immobilization forms and accelerated radiation damage studies of the US-specified plutonium ceramic for immobilizing plutonium. This intriguing and extraordinary cooperation on certain aspects of the weapons plutonium problem is now progressing well and much work with plutonium has been completed in the past two years. Because much excellent and unique scientific and engineering technical work has now been completed in Russia in many aspects of plutonium immobilization, this meeting in St. Petersburg was both timely and necessary to summarize, review, and discuss these efforts among those who performed the actual work. The results of this meeting will help the US and Russia jointly define the future direction of the Russian plutonium immobilization program, and make it an even stronger and more integrated Russian program. The two objectives for the meeting were to: (1) Bring together the Russian organizations, experts, and managers performing the work into one place for four days to review and discuss their work with each other; and (2) Publish a meeting summary and a proceedings to compile reports of all the

  15. Excessive exposures of diagnostic X-ray workers in India

    International Nuclear Information System (INIS)

    Ambiger, T.Y.; Shenoy, K.S.; Patel, P.H.

    1980-01-01

    The excessive exposures (i.e. exceeding 400 mrems per fortnight) of diagnostic X-ray workers revealed under the countrywide personnel monitoring programme in India have been analysed. The analysis covers the data collected over a period of ten years during 1965-1974. The radiation workers in medical X-ray diagnostic group receiving an excess dose are found to be less than 1%. Each case of the excess dose is throughly investigated and nongenuine cases are separated and causes for genuine excessive exposures are traced. The causes and the corrective measures are enumerated. (M.G.B.)

  16. Understanding Excess Emissions from Industrial Facilities: Evidence from Texas.

    Science.gov (United States)

    Zirogiannis, Nikolaos; Hollingsworth, Alex J; Konisky, David M

    2018-03-06

    We analyze excess emissions from industrial facilities in Texas using data from the Texas Commission on Environmental Quality. Emissions are characterized as excess if they are beyond a facility's permitted levels and if they occur during startups, shutdowns, or malfunctions. We provide summary data on both the pollutants most often emitted as excess emissions and the industrial sectors and facilities responsible for those emissions. Excess emissions often represent a substantial share of a facility's routine (or permitted) emissions. We find that while excess emissions events are frequent, the majority of excess emissions are emitted by the largest events. That is, the sum of emissions in the 96-100th percentile is often several orders of magnitude larger than the remaining excess emissions (i.e., the sum of emissions below the 95th percentile). Thus, the majority of events emit a small amount of pollution relative to the total amount emitted. In addition, a small group of high emitting facilities in the most polluting industrial sectors are responsible for the vast majority of excess emissions. Using an integrated assessment model, we estimate that the health damages in Texas from excess emissions are approximately $150 million annually.

  17. [Playing of wind instruments is associated with an obstructive pattern in the spirometry of adolescents with a good aerobic resistance capacity].

    Science.gov (United States)

    Granell, Javier; Granell, Jose; Ruiz, Diana; Tapias, Jose A

    2011-03-01

    There is controversy in the medical literature regarding the beneficial or detrimental effects of playing wind musical instruments on the respiratory system. The aim of this study is to analyse this relationship, taking the physical condition of the subjects into consideration. Cross-sectional observational study. Public institution with coordinated medium grade musical instruction and primary and secondary education. Young performers (between 13 and 17 years). We collected basic epidemiological parameters (gender, age, weight, size, heath status), and each subject underwent a fitness test ("course navette" cardiorespiratory fitness test) and a forced spirometry. We included 90 students, 53 females and 37 males. Thirty two were wind instrument players and 58 studied other instruments. The two groups were homogeneous with respect to gender, age and body mass index. The maximum oxygen uptake showed no significant difference (P=0.255), further demonstrating an adequate level of fitness compared to the general population. FVC was normal and similar in both groups (P=0.197). The FEV(1) percentage and the FEV(1)/FVC ratio were significantly lower (Pstudy of wind instruments was associated with an obstructive spirometric pattern in young musicians with a normal level of physical fitness. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  18. Complex variables

    CERN Document Server

    Fisher, Stephen D

    1999-01-01

    The most important topics in the theory and application of complex variables receive a thorough, coherent treatment in this introductory text. Intended for undergraduates or graduate students in science, mathematics, and engineering, this volume features hundreds of solved examples, exercises, and applications designed to foster a complete understanding of complex variables as well as an appreciation of their mathematical beauty and elegance. Prerequisites are minimal; a three-semester course in calculus will suffice to prepare students for discussions of these topics: the complex plane, basic

  19. Variable stars

    International Nuclear Information System (INIS)

    Feast, M.W.; Wenzel, W.; Fernie, J.D.; Percy, J.R.; Smak, J.; Gascoigne, S.C.B.; Grindley, J.E.; Lovell, B.; Sawyer Hogg, H.B.; Baker, N.; Fitch, W.S.; Rosino, L.; Gursky, H.

    1976-01-01

    A critical review of variable stars is presented. A fairly complete summary of major developments and discoveries during the period 1973-1975 is given. The broad developments and new trends are outlined. Essential problems for future research are identified. (B.R.H. )

  20. A new approach to analyse longitudinal epidemiological data with an excess of zeros.

    Science.gov (United States)

    Spriensma, Alette S; Hajos, Tibor R S; de Boer, Michiel R; Heymans, Martijn W; Twisk, Jos W R

    2013-02-20

    Within longitudinal epidemiological research, 'count' outcome variables with an excess of zeros frequently occur. Although these outcomes are frequently analysed with a linear mixed model, or a Poisson mixed model, a two-part mixed model would be better in analysing outcome variables with an excess of zeros. Therefore, objective of this paper was to introduce the relatively 'new' method of two-part joint regression modelling in longitudinal data analysis for outcome variables with an excess of zeros, and to compare the performance of this method to current approaches. Within an observational longitudinal dataset, we compared three techniques; two 'standard' approaches (a linear mixed model, and a Poisson mixed model), and a two-part joint mixed model (a binomial/Poisson mixed distribution model), including random intercepts and random slopes. Model fit indicators, and differences between predicted and observed values were used for comparisons. The analyses were performed with STATA using the GLLAMM procedure. Regarding the random intercept models, the two-part joint mixed model (binomial/Poisson) performed best. Adding random slopes for time to the models changed the sign of the regression coefficient for both the Poisson mixed model and the two-part joint mixed model (binomial/Poisson) and resulted into a much better fit. This paper showed that a two-part joint mixed model is a more appropriate method to analyse longitudinal data with an excess of zeros compared to a linear mixed model and a Poisson mixed model. However, in a model with random slopes for time a Poisson mixed model also performed remarkably well.

  1. Risk charts to identify low and excessive responders among first-cycle IVF/ICSI standard patients

    DEFF Research Database (Denmark)

    la Cour Freiesleben, N; Gerds, Thomas Alexander; Forman, Julie Lyng

    2011-01-01

    Ovarian stimulation carries a risk of either low or excessive ovarian response. The aim was to develop prognostic models for identification of standard (ovulatory and normal basal FSH) patients’ risks of low and excessive response to conventional stimulation for IVF/intracytoplasmic sperm injection....... Prospectively collected data on 276 first-cycle patients treated with 150 IU recombinant FSH (rFSH)/day in a long agonist protocol were analysed. Logistic regression analysis was applied to the outcome variables:low (seven or less follicles) and excessive (20 or more follicles) response. Variables were woman......’s age, menstrual cycle length, weight or body mass index, ovarian volume, antral follicle count (AFC) and basal FSH. The predictive performance of the models was evaluated from the prediction error (Brier score, %) where zero corresponds to a perfect prediction. Model stability was assessed using 1000...

  2. The effect of excessive iodine diet on thyroid function

    International Nuclear Information System (INIS)

    Wang Yuhua; Li Yaming

    2009-01-01

    The modify of the thyroid cell structure can be induced by excessive iodine diet. Then the disordered thyroid function can result in a number of thyroid disease. The radionucline thyroid imaging play an important role in diagnoses of thyroid. Amplify on the effect of excessive diet on thyroid function will be worthy instructing what preparation should do before doing the thyroid nuclide imaging. (authors)

  3. Management of excessive movable tissue: a modified impression technique.

    Science.gov (United States)

    Shum, Michael H C; Pow, Edmond H N

    2014-08-01

    Excessive movable tissue is a challenge in complete denture prosthetics. A modified impression technique is presented with polyvinyl siloxane impression material and a custom tray with relief areas and perforations in the area of the excessive movable tissue. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Excess isentropic compressibility and speed of sound of the ternary

    Indian Academy of Sciences (India)

    These excess properties of the binary mixtures were fitted to Redlich-Kister equation, while the Cibulka's equation was used to fit the values related to the values to the ternary system. These excess properties have been used to discuss the presence of significant interactions between the component molecules in the binary ...

  5. 30 CFR 75.323 - Actions for excessive methane.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Actions for excessive methane. 75.323 Section... excessive methane. (a) Location of tests. Tests for methane concentrations under this section shall be made.... (1) When 1.0 percent or more methane is present in a working place or an intake air course, including...

  6. Excess molar volumes and isentropic compressibilities of binary

    Indian Academy of Sciences (India)

    Excess molar volumes (E) and deviation in isentropic compressibilities (s) have been investigated from the density and speed of sound measurements of six binary liquid mixtures containing -alkanes over the entire range of composition at 298.15 K. Excess molar volume exhibits inversion in sign in one binary ...

  7. Goodwill, Excess Returns, and Determinants of Value Creation and Overpayment

    NARCIS (Netherlands)

    Lycklama a Nijeholt, M.; Grift, Y.K.|info:eu-repo/dai/nl/073586358

    2007-01-01

    In this article we have investigated whether the determinants of excess returns (especially of target excess returns) are valid for purchased goodwill as well. Among them are acquirer’s and target’s Tobin’s q, and debt assets ratio, that explain value creation of acquisitions, and relative size,

  8. Criminal Liability of Managers for Excessive Risk-Taking?

    NARCIS (Netherlands)

    Tosza, S.T.

    2016-01-01

    The aim of the thesis was to analyse and evaluate the criminalisation of excessively risky decisions taken by managers of limited liability companies. The potentially disastrous consequences of excessive risk-taking were powerfully highlighted by the most recent financial crunch, although its

  9. Sanitization and Disposal of Excess Information Technology Equipment

    Science.gov (United States)

    2009-09-21

    Report No. D-2009-104 September 21, 2009 Sanitization and Disposal of Excess Information Technology Equipment...2009 2. REPORT TYPE 3. DATES COVERED 00-00-2009 to 00-00-2009 4. TITLE AND SUBTITLE Sanitization and Disposal of Excess Information Technology ...Defense (Networks and Information Integration)/DOD Chief Information Officer DRMS Defense Reutilization and Marketing Service IT Information

  10. 12 CFR 740.3 - Advertising of excess insurance.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Advertising of excess insurance. 740.3 Section... ACCURACY OF ADVERTISING AND NOTICE OF INSURED STATUS § 740.3 Advertising of excess insurance. Any advertising that mentions share or savings account insurance provided by a party other than the NCUA must...

  11. 40 CFR 57.304 - Bypass, excess emissions and malfunctions.

    Science.gov (United States)

    2010-07-01

    ... (performance level of interim constant controls) or § 57.303 (plantwide emission limitation) of this subpart... limitation, as well as the operating data, documents, and calculations used in determining the magnitude of the excess emissions; (3) Time and duration of the excess emissions; (4) Identity of the equipment...

  12. 19 CFR 10.625 - Refunds of excess customs duties.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Refunds of excess customs duties. 10.625 Section 10.625 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT... and Apparel Goods § 10.625 Refunds of excess customs duties. (a) Applicability. Section 205 of the...

  13. A Practical Approach For Excess Bandwidth Distribution for EPONs

    KAUST Repository

    Elrasad, Amr

    2014-03-09

    This paper introduces a novel approach called Delayed Excess Scheduling (DES), which practically reuse the excess bandwidth in EPONs system. DES is suitable for the industrial deployment as it requires no timing constraint and achieves better performance compared to the previously reported schemes.

  14. Excess mortality in mothers of patients with polycystic ovary syndrome

    NARCIS (Netherlands)

    Louwers, Y. V.; Roest-Schalken, M. E.; Kleefstra, N.; van Lennep, J. Roeters; van den Berg, M.; Fauser, B. C. J. M.; Bilo, H. J. G.; Sijbrands, E. J. G.; Laven, J. S. E.

    STUDY QUESTION: Do diabetic parents of patients with polycystic ovary syndrome (PCOS) encounter excess mortality compared with the mortality of men and women with type 2 diabetes, recruited without selection for PCOS? SUMMARY ANSWER: Type 2 diabetes among mothers of PCOS patients results in excess

  15. 40 CFR 76.13 - Compliance and excess emissions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Compliance and excess emissions. 76.13 Section 76.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.13 Compliance and excess emissions...

  16. Teachers' Knowledge of Anxiety and Identification of Excessive Anxiety in

    Science.gov (United States)

    Headley, Clea; Campbell, Marilyn A.

    2013-01-01

    This study examined primary school teachers' knowledge of anxiety and excessive anxiety symptoms in children. Three hundred and fifteen primary school teachers completed a questionnaire exploring their definitions of anxiety and the indications they associated with excessive anxiety in primary school children. Results showed that teachers had an…

  17. ON INFRARED EXCESSES ASSOCIATED WITH Li-RICH K GIANTS

    Energy Technology Data Exchange (ETDEWEB)

    Rebull, Luisa M. [Spitzer Science Center (SSC) and Infrared Science Archive (IRSA), Infrared Processing and Analysis Center - IPAC, 1200 E. California Blvd., California Institute of Technology, Pasadena, CA 91125 (United States); Carlberg, Joleen K. [NASA Goddard Space Flight Center, Code 667, Greenbelt, MD 20771 (United States); Gibbs, John C.; Cashen, Sarah; Datta, Ashwin; Hodgson, Emily; Lince, Megan [Glencoe High School, 2700 NW Glencoe Rd., Hillsboro, OR 97124 (United States); Deeb, J. Elin [Bear Creek High School, 9800 W. Dartmouth Pl., Lakewood, CO 80227 (United States); Larsen, Estefania; Altepeter, Shailyn; Bucksbee, Ethan; Clarke, Matthew [Millard South High School, 14905 Q St., Omaha, NE 68137 (United States); Black, David V., E-mail: rebull@ipac.caltech.edu [Walden School of Liberal Arts, 4230 N. University Ave., Provo, UT 84604 (United States)

    2015-10-15

    Infrared (IR) excesses around K-type red giants (RGs) have previously been discovered using Infrared Astronomy Satellite (IRAS) data, and past studies have suggested a link between RGs with overabundant Li and IR excesses, implying the ejection of circumstellar shells or disks. We revisit the question of IR excesses around RGs using higher spatial resolution IR data, primarily from the Wide-field Infrared Survey Explorer. Our goal was to elucidate the link between three unusual RG properties: fast rotation, enriched Li, and IR excess. Our sample of RGs includes those with previous IR detections, a sample with well-defined rotation and Li abundance measurements with no previous IR measurements, and a large sample of RGs asserted to be Li-rich in the literature; we have 316 targets thought to be K giants, about 40% of which we take to be Li-rich. In 24 cases with previous detections of IR excess at low spatial resolution, we believe that source confusion is playing a role, in that either (a) the source that is bright in the optical is not responsible for the IR flux, or (b) there is more than one source responsible for the IR flux as measured in IRAS. We looked for IR excesses in the remaining sources, identifying 28 that have significant IR excesses by ∼20 μm (with possible excesses for 2 additional sources). There appears to be an intriguing correlation in that the largest IR excesses are all in Li-rich K giants, though very few Li-rich K giants have IR excesses (large or small). These largest IR excesses also tend to be found in the fastest rotators. There is no correlation of IR excess with the carbon isotopic ratio, {sup 12}C/{sup 13}C. IR excesses by 20 μm, though relatively rare, are at least twice as common among our sample of Li-rich K giants. If dust shell production is a common by-product of Li enrichment mechanisms, these observations suggest that the IR excess stage is very short-lived, which is supported by theoretical calculations. Conversely, the

  18. Depression, materialism, and excessive Internet use in relation to compulsive buying.

    Science.gov (United States)

    Mueller, Astrid; Mitchell, James E; Peterson, Lisa A; Faber, Ronald J; Steffen, Kristine J; Crosby, Ross D; Claes, Laurence

    2011-01-01

    The objective of the study was to examine the relationship between compulsive buying (CB), depression, materialism, and excessive Internet use. An online survey of 387 consumers was conducted including questions about demographics and shopping venues, the Compulsive Buying Scale, the Patient Health Questionnaire Depression Scale, the Materialistic Values Scale, and questions concerning excessive Internet use. Seventeen percent of the participants reported Compulsive Buying Scale scores less than -1.34 and were considered to be having CB. Participants with CB did not significantly differ from those without CB regarding age, sex, marital status, annual household income, and shopping preferences. Individuals with CB reported more depressive symptoms, higher materialistic values endorsement, and more severe excessive Internet use compared with those without CB. Results of a stepwise logistic regression analysis with CB as the dependent variable showed that materialism and depression were associated with CB, whereas excessive Internet use was not. Materialism and depression jointly influence CB. Further research is needed to examine the influence of materialism on CB in a clinical sample consisting of patients with diagnosed CB. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Physical, clinical, and psychosocial parameters of adolescents with different degrees of excess weight

    Directory of Open Access Journals (Sweden)

    Vanessa Drieli Seron Antonini

    2014-12-01

    Full Text Available OBJECTIVE: To compare body composition, hemodynamic parameters, health-related physical fitness, and health-related quality of life of adolescents with anthropometric diagnosis of overweight, obesity, and severe obesity.METHODS: 220 adolescents with excess body weight were enrolled. They were beginners in a intervention program that included patients based on age, availability, presence of excess body weight, place of residence, and agreement to participate in the study. This study collected anthropometric and hemodynamic variables, health-related physical fitness, and health-related quality of life of the adolescents. To compare the three groups according to nutritional status, parametric and non-parametric tests were applied. Significance level was set at p0.05. Body weight, body mass index, waist and hip circumference, and systolic blood pressure increased as degree of excess weightincreased (p<0.05. Dyastolic blood pressure of the severe obesity group was higher than the other groups (p<0.05. There was an association between the degree of excess weight and the prevalence of altered blood pressure (overweight: 12.1%; obesity: 28.1%; severe obesity: 45.5%; p<0.001. The results were similar when genders were analyzed separately.CONCLUSION: Results suggest that overweight adolescents presented similar results compared to obese and severely obese adolescents in most of the parameters analyzed.

  20. Estimating the U.S. prevalence of chronic obstructive pulmonary disease using pre- and post-bronchodilator spirometry: the National Health and Nutrition Examination Survey (NHANES) 2007–2010

    Science.gov (United States)

    2013-01-01

    Background During 2007–2010, the National Health and Nutrition Examination Survey (NHANES) conducted a spirometry component which obtained pre-bronchodilator pulmonary lung function data on a nationally representative sample of US adults aged 6–79 years and post-bronchodilator pulmonary lung function data for the subset of adults with airflow limitation. The goals of this study were to 1) compute prevalence estimates of chronic obstructive pulmonary disease (COPD) using pre-bronchodilator and post-bronchodilator spirometry measurements and fixed ratio and lower limit of normal (LLN) diagnostic criteria and 2) examine the potential impact of nonresponse on the estimates. Methods This analysis was limited to those aged 40–79 years who were eligible for NHANES pre-bronchodilator spirometry (n=7,104). Examinees with likely airflow limitation were further eligible for post-bronchodilator testing (n=1,110). Persons were classified as having COPD based on FEV1/FVC spirometry but self-reporting both daytime supplemental oxygen therapy plus emphysema and/or current chronic bronchitis were also classified as having COPD. The final analytic samples for pre-bronchodilator and post-bronchodilator analyses were 77.1% (n=5,477) and 50.8% (n=564) of those eligible, respectively. To account for non-response, NHANES examination weights were adjusted to the eligible pre-bronchodilator and post-bronchodilator subpopulations. Results In 2007–2010, using the fixed ratio criterion and pre-bronchodilator test results, COPD prevalence was 20.9% (SE 1.1) among US adults aged 40–79 years. Applying the same criterion to post-bronchodilator test results, prevalence was 14.0% (SE 1.0). Using the LLN criterion and pre-bronchodilator test results, the COPD prevalence was 15.4% (SE 0.8), while applying the same criterion to post-bronchodilator test results, prevalence was 10.2% (SE 0.8). Conclusions The overall COPD prevalence among US adults aged 40–79 years varied from 10.2% to 20

  1. Diseño de un programa de formación básico para conseguir espirometrías de calidad Design of a basic training program to get quality spirometry

    Directory of Open Access Journals (Sweden)

    Joan Escarrabill

    2012-06-01

    Full Text Available Introducción. La espirometría forzada es una manera sencilla y no invasiva de valorar la función pulmonar. La obtención de una espirometría de calidad requiere formación, condiciones técnicas adecuadas (calibración, mantenimiento y ubicación del aparato y colaboración del paciente. Diversos trabajos han constatado déficits formativos de los profesionales, relacionados en parte con la elevada rotación en un mismo puesto, la falta de sistemática en la incorporación de nuevos profesionales que realizan espirometrías y la ausencia de planes de evaluación periódica de competencias. Materiales y métodos. En el marco del Plan Director de Enfermedades del Aparato Respiratorio (PDMAR se ha diseñado un programa formativo mínimo teórico-práctico de 16 horas de duración, basado en el programa de formación del National Institute for Occupational Safety and Health y de las iniciativas que surgen en el marco de la European Respiratory Society. Durante el año 2010 se realizaron 13 cursos en los que participaron 307 profesionales. Resultados. Las diferencias observadas entre la evaluación de conocimientos previos y la evaluación final fue estadísticamente significativa (p Introduction. The spirometry is a simple and noninvasive test to assess lung function. Obtaining a spirometry of quality requires training, appropriate technical conditions (calibration, maintenance and location of the device, and patient cooperation. Several studies have found professional training deficits related to a high turnover in the same place, the lack of systematic training when new professionals performing spirometry are incorporated and the lack of competences' periodic evaluation. Materials and methods. The Master Plan for respiratory diseases (PDMAR has designed a minimum practical/theoretical training program (16 hours based on the training program of the National Institute for Occupational Safety and Health and the European Respiratory Society

  2. Industrial excess heat for district heating in Denmark

    International Nuclear Information System (INIS)

    Bühler, Fabian; Petrović, Stefan; Karlsson, Kenneth; Elmegaard, Brian

    2017-01-01

    Highlights: •Method for utilisation potential of industrial excess heat for district heating. •Industrial excess heat from thermal processes is quantified at single production units. •Linking of industrial excess heat sources and district heating demands done in GIS. •Excess heat recovery using direct heat transfer and heat pumps. •5.1% of the Danish district heating demand could be supplied by industrial excess heat. -- Abstract: Excess heat is available from various sources and its utilisation could reduce the primary energy use. The accessibility of this heat is however dependent amongst others on the source and sink temperature, amount and potential users in its vicinity. In this work a new method is developed which analyses excess heat sources from the industrial sector and how they could be used for district heating. This method first allocates excess heat to single production units by introducing and validating a new approach. Spatial analysis of the heat sources and consumers are then performed to evaluate the potential for using them for district heating. In this way the theoretical potential of using the excess heat for covering the heating demand of buildings is determined. Through the use of industry specific temperature profiles the heat usable directly or via heat pumps is further found. A sensitivity analysis investigates the impact of future energy efficiency measures in the industry, buildings and the district heating grid on the national potential. The results show that for the case study of Denmark, 1.36 TWh of district heat could be provided annually with industrial excess heat from thermal processes which equals 5.1% of the current demand. More than half of this heat was found to be usable directly, without the need for a heat pump.

  3. Energetics and dynamics of excess electrons in simple fluids

    International Nuclear Information System (INIS)

    Space, B.

    1992-01-01

    Excess electronic dynamical and equilibrium properties are modeled in both polarizable and nonpolarizable noble gas fluids. Explicit dynamical calculations are carried out for excess electrons in fluid helium, where excess electronic eigenstates are localized. Energetics and dynamics are considered for fluids which span the entire range of polarizability present in the rare gases. Excess electronic eigenstates and eigenvalues are calculated for fluids of helium, argon and xenon. Both equilibrium and dynamical information is obtained from the calculation of these wavefunctions. A surface hopping trajectory method for studying nonadiabatic excess electronic relaxation in condensed systems is used to explore the nonadiabatic relaxation after photoexciting an equilibrated excess electron in dense fluid helium. The different types on nonadiabatic phenomena which are important in excess electronic relaxation are surveyed. The same surface hopping trajectory method is also used to study the rapid nonadiabatic relaxation after an excess electron is injected into unperturbed fluid helium. Several distinctively different relaxation processes, characterized by their relative importance at different times during the relaxation to a localized equilibrium state, are detailed. Though the dynamical properties of excess electrons under the conditions considered here have never been studied before, the behavior is remarkably similar to that observed in both experimental and theoretical studies of electron hydration dynamics, indicating that the processes described may be very general relaxation mechanisms for localization and trapping in fluids. Additionally, ground state energies of an excess electron, e 0 , are computed as a function of solvent density using model electron-atom pseudopotentials in fluid helium, argon, and xenon. The nonuniqueness of the pseudopotential description of electron-molecule interactions is demonstrated

  4. Response of water vapour D-excess to land-atmosphere interactions in a semi-arid environment

    KAUST Repository

    Parkes, Stephen; McCabe, Matthew; Griffiths, Alan D.; Wang, Lixin; Chambers, Scott; Ershadi, Ali; Williams, Alastair G; Strauss, Josiah; Element, Adrian

    2016-01-01

    nocturnal inversion layer caused a lowering of dv values near the surface. In addition, transient mixing of vapour with a higher D-excess from above the nocturnal inversion modified these values, causing large variability during the night. These results indicate dET can generally be expected to show

  5. Prevalence of excessive screen time and associated factors in adolescents

    Directory of Open Access Journals (Sweden)

    Joana Marcela Sales de Lucena

    2015-12-01

    Full Text Available Objective: To determine the prevalence of excessive screen time and to analyze associated factors among adolescents. Methods: This was a cross-sectional school-based epidemiological study with 2874 high school adolescents with age 14-19 years (57.8% female from public and private schools in the city of João Pessoa, PB, Northeast Brazil. Excessive screen time was defined as watching television and playing video games or using the computer for more than 2 h/day. The associated factors analyzed were: sociodemographic (gender, age, economic class, and skin color, physical activity and nutritional status of adolescents. Results: The prevalence of excessive screen time was 79.5% (95%CI 78.1-81.1 and it was higher in males (84.3% compared to females (76.1%; p<0.001. In multivariate analysis, adolescent males, those aged 14-15 year old and the highest economic class had higher chances of exposure to excessive screen time. The level of physical activity and nutritional status of adolescents were not associated with excessive screen time. Conclusions: The prevalence of excessive screen time was high and varied according to sociodemographic characteristics of adolescents. It is necessary to develop interventions to reduce the excessive screen time among adolescents, particularly in subgroups with higher exposure.

  6. Cooking rice in excess water reduces both arsenic and enriched vitamins in the cooked grain.

    Science.gov (United States)

    Gray, Patrick J; Conklin, Sean D; Todorov, Todor I; Kasko, Sasha M

    2016-01-01

    This paper reports the effects of rinsing rice and cooking it in variable amounts of water on total arsenic, inorganic arsenic, iron, cadmium, manganese, folate, thiamin and niacin in the cooked grain. We prepared multiple rice varietals both rinsed and unrinsed and with varying amounts of cooking water. Rinsing rice before cooking has a minimal effect on the arsenic (As) content of the cooked grain, but washes enriched iron, folate, thiamin and niacin from polished and parboiled rice. Cooking rice in excess water efficiently reduces the amount of As in the cooked grain. Excess water cooking reduces average inorganic As by 40% from long grain polished, 60% from parboiled and 50% from brown rice. Iron, folate, niacin and thiamin are reduced by 50-70% for enriched polished and parboiled rice, but significantly less so for brown rice, which is not enriched.

  7. Timing of Excessive Weight Gain During Pregnancy Modulates Newborn Anthropometry.

    Science.gov (United States)

    Ruchat, Stephanie-May; Allard, Catherine; Doyon, Myriam; Lacroix, Marilyn; Guillemette, Laetitia; Patenaude, Julie; Battista, Marie-Claude; Ardilouze, Jean-Luc; Perron, Patrice; Bouchard, Luigi; Hivert, Marie-France

    2016-02-01

    Excessive gestational weight gain (GWG) is associated with increased birth weight and neonatal adiposity. However, timing of excessive GWG may have a differential impact on birth outcomes. The objective of this study was to compare the effect of early and mid/late excessive GWG on newborn anthropometry in the context of the Canadian clinical recommendations that are specific for first trimester and for second/third trimesters based on maternal pre-pregnancy BMI. We included 607 glucose-tolerant women in our main analyses, after excluding women who had less than the recommended total GWG. Maternal body weight was measured in early pregnancy, mid-pregnancy, and late pregnancy. Maternal and fetal clinical outcomes were collected, including newborn anthropometry. Women were divided into four groups according to the Canadian guidelines for GWG in the first and in the second/third trimesters: (1) "overall non-excessive" (reference group); (2) "early excessive GWG"; (3) "mid/late excessive GWG"; and (4) "overall excessive GWG." Differences in newborn anthropometry were tested across GWG categories. Women had a mean (±SD) pre-pregnancy BMI of 24.7 ± 5.2 kg/m(2) and total GWG of 15.3 ± 4.4 kg. Women with mid/late excessive GWG gave birth to heavier babies (gestational age-adjusted birth weight z-score 0.33 ± 0.91) compared with women in the reference group (0.00 ± 0.77, P = 0.007), whereas women with early excessive GWG gave birth to babies of similar weight (gestational age-adjusted z-score 0.01 ± 0.86) to the reference group (0.00 ± 0.77, P = 0.84). When we stratified our analyses and investigated women who gained within the recommendations for total GWG, mid/late excessive GWG specifically was associated with greater newborn size, similar to our main analyses. Excessive GWG in mid/late pregnancy in women who did not gain weight excessively in early pregnancy is associated with increased birth size, even in those who gained within the Canadian recommendations

  8. Complex variables

    CERN Document Server

    Flanigan, Francis J

    2010-01-01

    A caution to mathematics professors: Complex Variables does not follow conventional outlines of course material. One reviewer noting its originality wrote: ""A standard text is often preferred [to a superior text like this] because the professor knows the order of topics and the problems, and doesn't really have to pay attention to the text. He can go to class without preparation."" Not so here-Dr. Flanigan treats this most important field of contemporary mathematics in a most unusual way. While all the material for an advanced undergraduate or first-year graduate course is covered, discussion

  9. Thermodynamic properties of binary mixtures of tetrahydropyran with pyridine and isomeric picolines: Excess molar volumes, excess molar enthalpies and excess isentropic compressibilities

    International Nuclear Information System (INIS)

    Saini, Neeti; Jangra, Sunil K.; Yadav, J.S.; Sharma, Dimple; Sharma, V.K.

    2011-01-01

    Research highlights: → Densities, ρ and speeds of sound, u of tetrahydropyran (i) + pyridine or α-, β- or γ-picoline (j) binary mixtures at 298.15, 303.15 and 308.15 K and excess molar enthalpies, H E of the same set of mixtures at 308.15 K have been measured as a function of composition. → The observed densities and speeds of sound values have been employed to determine excess molar volumes, V E and excess isentropic compressibilities, κ S E . → Topology of the constituents of mixtures has been utilized (Graph theory) successfully to predict V E , H E and κ S E data of the investigated mixtures. → Thermodynamic data of the various mixtures have also been analyzed in terms of Prigogine-Flory-Patterson (PFP) theory. - Abstract: Densities, ρ and speeds of sound, u of tetrahydropyran (i) + pyridine or α-, β- or γ- picoline (j) binary mixtures at 298.15, 303.15 and 308.15 K and excess molar enthalpies, H E of the same set of mixtures at 308.15 K have been measured as a function of composition using an anton Parr vibrating-tube digital density and sound analyzer (model DSA 5000) and 2-drop micro-calorimeter, respectively. The resulting density and speed of sound data of the investigated mixtures have been utilized to predict excess molar volumes, V E and excess isentropic compressibilities, κ S E . The observed data have been analyzed in terms of (i) Graph theory; (ii) Prigogine-Flory-Patterson theory. It has been observed that V E , H E and κ S E data predicted by Graph theory compare well with their experimental values.

  10. Association of symptoms of attention-deficit/hyperactivity disorder with symptoms of excessive exercising in an adult general population sample.

    Science.gov (United States)

    Berger, Nikolas A A; Müller, Astrid; Brähler, Elmar; Philipsen, Alexandra; de Zwaan, Martina

    2014-09-12

    An increasing number of studies suggest that physical activity can alleviate symptoms of ADHD in children. In adults there are currently insufficient data available on this subject. Interestingly, ADHD and forms of excessive exercising have both been shown to occur more frequently in adult athletes. The aim of the present study was to empirically investigate the association of ADHD and excessive exercising in the adult general population. For diagnosis of adult and childhood ADHD a large representative sample of the German general population (n = 1,615) completed a retrospective assessment of childhood ADHD and a self-report assessment of adult ADHD. Excessive exercising as well as putative mediating variables such as eating related psychopathology, depression, and anxiety were assessed using standardized self-rating instruments. Individuals with childhood only ADHD had a significantly higher frequency of excessive exercising (9.0%) than individuals without ADHD (2.7%). Excessive exercising was significantly associated with childhood only ADHD compared to no ADHD with an odds ratio of 3.239 even after controlling for socio-demographic variables, BMI, eating related and general psychopathology. Our data show that excessive exercising is significantly overrepresented in individuals in which ADHD symptoms in childhood have not persisted into adulthood. We thus hypothesize that a subgroup of individuals might suppress ADHD symptoms by excessive sporting activities. Although in healthy adults physical activity has been associated with immediate and long term improvements in cognitive functioning, studies empirically investigating associations between the effects of physical activity and adult ADHD are rare. Further studies are warranted to explore the potential role of physical activity in the treatment of ADHD in adults.

  11. Evaluation of effective dose and excess lifetime cancer risk from ...

    African Journals Online (AJOL)

    Evaluation of effective dose and excess lifetime cancer risk from indoor and outdoor gamma dose rate of university of Port Harcourt Teaching Hospital, Rivers State. ... Therefore, the management of University of Port Harcourt teaching hospital ...

  12. Implications of /sup 36/A excess on Venus

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, M [Tokyo Univ. (Japan). Inst. of Space and Aeronautical Science

    1979-05-01

    The finding of /sup 36/A excess on Venus by the mass-spectroscopic measurement of the Venus Pioneer appears to endorse the more rapid accretion theory of Venus than the Earth and the secondary origin of the terrestrial atmosphere.

  13. Gene Linked to Excess Male Hormones in Female Infertility Disorder

    Science.gov (United States)

    ... April 15, 2014 Gene linked to excess male hormones in female infertility disorder Discovery by NIH-supported ... may lead to the overproduction of androgens — male hormones similar to testosterone — occurring in women with polycystic ...

  14. Excess molar volumes and isentropic compressibilities of binary ...

    Indian Academy of Sciences (India)

    Excess molar volume; binary liquid mixtures; isentropic compressibility; intermolecular interactions. ... mixtures are essential for fluid flow, mass flow and heat transfer processes in chemical ... Experimentally determined values of density(ρ).

  15. Characteristics of adolescent excessive drinkers compared with consumers and abstainers

    NARCIS (Netherlands)

    Tomcikova, Zuzana; Geckova, Andrea Madarasova; van Dijk, Jitse P.; Reijneveld, Sijmen A.

    Introduction and Aims. This study aimed at comparing adolescent abstainers, consumers and excessive drinkers in terms of family characteristics (structure of family, socioeconomic factors), perceived social support, personality characteristics (extraversion, self-esteem, aggression) and well-being.

  16. Estimating the burden of disease attributable to excess body weight ...

    African Journals Online (AJOL)

    Monte Carlo simulation-modelling techniques were used for the uncertainty analysis. ... Deaths and disability-adjusted life years (DALYs) from ischaemic heart disease, ... lasting change in the determinants and impact of excess body weight.

  17. Industrial excess heat for district heating in Denmark

    DEFF Research Database (Denmark)

    Bühler, Fabian; Petrovic, Stefan; Karlsson, Kenneth Bernard

    2017-01-01

    analyses excess heat sources from the industrial sector and how they could be used for district heating. This method first allocates excess heat to single production units by introducing and validating a new approach. Spatial analysis of the heat sources and consumers are then performed to evaluate...... the potential for using them for district heating. In this way the theoretical potential of using the excess heat for covering the heating demand of buildings is determined. Through the use of industry specific temperature profiles the heat usable directly or via heat pumps is further found. A sensitivity...... analysis investigates the impact of future energy efficiency measures in the industry, buildings and the district heating grid on the national potential. The results show that for the case study of Denmark, 1.36 TWh of district heat could be provided annually with industrial excess heat from thermal...

  18. Targets to treat androgen excess in polycystic ovary syndrome.

    Science.gov (United States)

    Luque-Ramírez, Manuel; Escobar-Morreale, Héctor Francisco

    2015-01-01

    The polycystic ovary syndrome (PCOS) is a common androgen disorder in reproductive-aged women. Excessive biosynthesis and secretion of androgens by steroidogenic tissues is its central pathogenetic mechanism. The authors review the potential targets and new drugs to treat androgen excess in PCOS. Besides our lab's experience, a systematic search (MEDLINE, Cochrane library, ClinicalTriasl.gov, EU Clinical Trials Register and hand-searching) regarding observational studies, randomized clinical trials, systematic reviews, meta-analyses and patents about this topic was performed. PCOS has a heterogeneous clinical presentation. It is unlikely that a single drug would cover all its possible manifestations. Available treatments for androgen excess are not free of side effects that are of particular concern in these women who suffer from cardiometabolic risk even without treatment. A precise characterization of the source of androgen excess must tailor antiandrogenic management in each woman, avoiding undesirable side effects.

  19. Modelling of excess noise attnuation by grass and forest | Onuu ...

    African Journals Online (AJOL)

    , guinea grass (panicum maximum) and forest which comprises iroko (milicia ezcelea) and white afara (terminalia superba) trees in the ratio of 2:1 approximately. Excess noise attenuation spectra have been plotted for the grass and forest for ...

  20. Iodine deficiency and iodine excess in Jiangsu Province, China

    NARCIS (Netherlands)

    Zhao, J.

    2001-01-01

    Keywords:
    iodine deficiency, iodine excess, endemic goiter, drinking water, iodine intake, thyroid function, thyroid size, iodized salt, iodized oil, IQ, physical development, hearing capacity, epidemiology, meta-analysis, IDD, randomized trial, intervention, USA, Bangladesh,

  1. Excess Volumes and Excess Isentropic Compressibilities of Binary Liquid Mixtures of Trichloroethylene with Esters at 303.15 K

    Science.gov (United States)

    Ramanaiah, S.; Rao, C. Narasimha; Nagaraja, P.; Venkateswarlu, P.

    2015-11-01

    Exces volumes, VE, and excess isentropic compressibilities, κSE, have been reported as a function of composition for binary liquid mixtures of trichloroethylene with ethyl acetate, n-propyl acetate, and n-butyl acetate at 303.15 K. Isentropic compressibilities are calculated using measured sound speeds and density data for pure components and for binary mixtures. Excess volumes and excess isentropic compressibilities are found to be negative for the three systems studied over the entire composition range at 303.15 K, whereas these values become more negative with an increase of carbon chain length. The results are discussed in terms of intermolecular interactions between unlike molecules.

  2. Dietary patterns are associated with excess weight and abdominal obesity in a cohort of young Brazilian adults.

    Science.gov (United States)

    Machado Arruda, Soraia Pinheiro; da Silva, Antônio Augusto Moura; Kac, Gilberto; Vilela, Ana Amélia Freitas; Goldani, Marcelo; Bettiol, Heloisa; Barbieri, Marco Antônio

    2016-09-01

    The objective of the present study was to investigate whether dietary patterns are associated with excess weight and abdominal obesity among young adults (23-25 years). A cross-sectional study was conducted on 2061 participants of a birth cohort from Ribeirão Preto, Brazil, started in 1978-1979. Twenty-seven subjects with caloric intake outside ±3 standard deviation range were excluded, leaving 2034 individuals. Excess weight was defined as body mass index (BMI ≥ 25 kg/m(2)), abdominal obesity as waist circumference (WC > 80 cm for women; >90 cm for men) and waist/hip ratio (WHR > 0.85 for women; >0.90 for men). Poisson regression with robust variance adjustment was used to estimate the prevalence ratio (PR) adjusted for socio-demographic and lifestyle variables. Four dietary patterns were identified by principal component analysis: healthy, traditional Brazilian, bar and energy dense. In the adjusted analysis, the bar pattern was associated with a higher prevalence of excess weight (PR 1.46; 95 % CI 1.23-1.73) and abdominal obesity based on WHR (PR 2.19; 95 % CI 1.59-3.01). The energy-dense pattern was associated with a lower prevalence of excess weight (PR 0.73; 95 % CI 0.61-0.88). Men with greater adherence to the traditional Brazilian pattern showed a lower prevalence of excess weight (PR 0.65; 95 % CI 0.51-0.82), but no association was found for women. There was no association between the healthy pattern and excess weight/abdominal obesity. In this sample, the bar pattern was associated with higher prevalences of excess weight and abdominal obesity, while the energy-dense (for both genders) and traditional Brazilian (only for men) patterns were associated with lower prevalences of excess weight.

  3. State dependent pseudo-resonances and excess noise

    OpenAIRE

    Papoff, F.; D'Alessandro, G.; Oppo, G.Luca

    2008-01-01

    We show that strong response to nonresonant modulations and excess noise are state dependent in generic nonlinear systems; i.e., they affect some output states but are absent from others. This is demonstrated in complex Swift-Hohenberg models relevant to optics, where it is caused by the non-normality of the linearized stability operators around selected output states, even though the cavity modes are orthogonal. In particular, we find the effective parameters that control excess noise and th...

  4. Excess costs of social anxiety disorder in Germany.

    Science.gov (United States)

    Dams, Judith; König, Hans-Helmut; Bleibler, Florian; Hoyer, Jürgen; Wiltink, Jörg; Beutel, Manfred E; Salzer, Simone; Herpertz, Stephan; Willutzki, Ulrike; Strauß, Bernhard; Leibing, Eric; Leichsenring, Falk; Konnopka, Alexander

    2017-04-15

    Social anxiety disorder is one of the most frequent mental disorders. It is often associated with mental comorbidities and causes a high economic burden. The aim of our analysis was to estimate the excess costs of patients with social anxiety disorder compared to persons without anxiety disorder in Germany. Excess costs of social anxiety disorder were determined by comparing two data sets. Patient data came from the SOPHO-NET study A1 (n=495), whereas data of persons without anxiety disorder originated from a representative phone survey (n=3213) of the general German population. Missing data were handled by "Multiple Imputation by Chained Equations". Both data sets were matched using "Entropy Balancing". Excess costs were calculated from a societal perspective for the year 2014 using general linear regression with a gamma distribution and log-link function. Analyses considered direct costs (in- and outpatient treatment, rehabilitation, and professional and informal care) and indirect costs due to absenteeism from work. Total six-month excess costs amounted to 451€ (95% CI: 199€-703€). Excess costs were mainly caused by indirect excess costs due to absenteeism from work of 317€ (95% CI: 172€-461€), whereas direct excess costs amounted to 134€ (95% CI: 110€-159€). Costs for medication, unemployment and disability pension was not evaluated. Social anxiety disorder was associated with statistically significant excess costs, in particular due to indirect costs. As patients in general are often unaware of their disorder or its severity, awareness should be strengthened. Prevention and early treatment might reduce long-term indirect costs. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Excessive computer game playing : evidence for addiction and aggression?

    OpenAIRE

    Grüsser, SM; Thalemann, R; Griffiths, MD

    2007-01-01

    Computer games have become an ever-increasing part of many adolescents’ day-to-day lives. Coupled with this phenomenon, reports of excessive gaming (computer game playing) denominated as “computer/video game addiction” have been discussed in the popular press as well as in recent scientific research. The aim of the present study was the investigation of the addictive potential of gaming as well as the relationship between excessive gaming and aggressive attitudes and behavior. A sample compri...

  6. A Portable Burn Pan for the Disposal of Excess Propellants

    Science.gov (United States)

    2016-06-01

    2013 - 06/01/2016 A Portable Burn Pan for the Disposal of Excess Propellants Michael Walsh USA CRREL USA CRREL 72 Lyme Road Hanover, NH 03755...Army Alaska XRF X-Ray Florescence vii ACKNOWLEDGEMENTS Project ER-201323, A Portable Burn Pan for the Disposal of Gun Propellants, was a very...contamination problem while allowing troops to train as they fight, we have developed a portable training device for burning excess gun propellants. 1.1

  7. Asymmetric Dark Matter Models and the LHC Diphoton Excess

    DEFF Research Database (Denmark)

    Frandsen, Mads T.; Shoemaker, Ian M.

    2016-01-01

    The existence of dark matter (DM) and the origin of the baryon asymmetry are persistent indications that the SM is incomplete. More recently, the ATLAS and CMS experiments have observed an excess of diphoton events with invariant mass of about 750 GeV. One interpretation of this excess is decays...... have for models of asymmetric DM that attempt to account for the similarity of the dark and visible matter abundances....

  8. Excess Molar Volumes and Excess Molar Enthalpies in Binary Systems N-alkyl-triethylammonium bis(trifluoromethylsulfonyl)imide + Methanol

    Czech Academy of Sciences Publication Activity Database

    Machanová, Karolina; Troncoso, J.; Jacquemin, J.; Bendová, Magdalena

    2014-01-01

    Roč. 363, FEB 15 (2014), s. 156-166 ISSN 0378-3812 Institutional support: RVO:67985858 Keywords : ionic liquids * excess properties * binary mixtures Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.200, year: 2014

  9. EXCESSIVE INTERNET USE AND PSYCHOPATHOLOGY: THE ROLE OF COPING

    Directory of Open Access Journals (Sweden)

    Daria J. Kuss

    2017-02-01

    Full Text Available Objective: In 2013, the American Psychiatric Association included Internet Gaming Disorder in the diagnostic manual as a condition which requires further research, indicating the scientific and clinical community are aware of potential health concerns as a consequence of excessive Internet use. From a clinical point of view, it appears that excessive/addictive Internet use is often comorbid with further psychopathologies and assessing comorbidity is relevant in clinical practice, treatment outcome and prevention as the probability to become addicted to using the Internet accelerates with additional (subclinical symptoms. Moreover, research indicates individuals play computer games excessively to cope with everyday stressors and to regulate their emotions by applying media-focused coping strategies, suggesting pathological computer game players play in order to relieve stress and to avoid daily hassles. The aims of this research were to replicate and extend previous findings and explanations of the complexities of the relationships between excessive Internet use and Internet addiction, psychopathology and dysfunctional coping strategies. Method: Participants included 681 Polish university students sampled using an online battery of validated psychometric instruments. Results: Results of structural equation models revealed dysfunctional coping strategies (i.e., distraction, denial, self-blame, substance use, venting, media use, and behavioural disengagement significantly predict excessive Internet use, and the data fit the theoretical model well. A second SEM showed media-focused coping and substance use coping significantly mediate the relationship between psychopathology (operationalised via the Global Severity Index and excessive Internet use. Conclusions: The findings lend support to the self-medication hypothesis of addictive disorders, and suggest psychopathology and dysfunctional coping have additive effects on excessive Internet use.

  10. Calculating excess lifetime risk in relative risk models

    International Nuclear Information System (INIS)

    Vaeth, M.; Pierce, D.A.

    1990-01-01

    When assessing the impact of radiation exposure it is common practice to present the final conclusions in terms of excess lifetime cancer risk in a population exposed to a given dose. The present investigation is mainly a methodological study focusing on some of the major issues and uncertainties involved in calculating such excess lifetime risks and related risk projection methods. The age-constant relative risk model used in the recent analyses of the cancer mortality that was observed in the follow-up of the cohort of A-bomb survivors in Hiroshima and Nagasaki is used to describe the effect of the exposure on the cancer mortality. In this type of model the excess relative risk is constant in age-at-risk, but depends on the age-at-exposure. Calculation of excess lifetime risks usually requires rather complicated life-table computations. In this paper we propose a simple approximation to the excess lifetime risk; the validity of the approximation for low levels of exposure is justified empirically as well as theoretically. This approximation provides important guidance in understanding the influence of the various factors involved in risk projections. Among the further topics considered are the influence of a latent period, the additional problems involved in calculations of site-specific excess lifetime cancer risks, the consequences of a leveling off or a plateau in the excess relative risk, and the uncertainties involved in transferring results from one population to another. The main part of this study relates to the situation with a single, instantaneous exposure, but a brief discussion is also given of the problem with a continuous exposure at a low-dose rate

  11. Alterations of the Lipid Metabolome in Dairy Cows Experiencing Excessive Lipolysis Early Postpartum.

    Science.gov (United States)

    Humer, Elke; Khol-Parisini, Annabella; Metzler-Zebeli, Barbara U; Gruber, Leonhard; Zebeli, Qendrim

    2016-01-01

    A decrease in insulin sensitivity enhances adipose tissue lipolysis helping early lactation cows counteracting their energy deficit. However, excessive lipolysis poses serious health risks for cows, and its underlying mechanisms are not clearly understood. The present study used targeted ESI-LC-MS/MS-based metabolomics and indirect insulin sensitivity measurements to evaluate metabolic alterations in the serum of dairy cows of various parities experiencing variable lipolysis early postpartum. Thirty (12 primiparous and 18 multiparous) cows of Holstein Friesian and Simmental breeds, fed the same diet and kept under the same management conditions, were sampled at d 21 postpartum and classified as low (n = 10), medium (n = 8), and high (n = 12) lipolysis groups, based on serum concentration of nonesterified fatty acids. Overall, excessive lipolysis in the high group came along with impaired estimated insulin sensitivity and characteristic shifts in acylcarnitine, sphingomyelin, phosphatidylcholine and lysophospholipid metabolome profiles compared to the low group. From the detected phosphatidylcholines mainly those with diacyl-residues showed differences among lipolysis groups. Furthermore, more than half of the detected sphingomyelins were increased in cows experiencing high lipomobilization. Additionally, strong differences in serum acylcarnitines were noticed among lipolysis groups. The study suggests an altered serum phospholipidome in dairy cows associated with an increase in certain long-chain sphingomyelins and the progression of disturbed insulin function. In conclusion, the present study revealed 37 key metabolites as part of alterations in the synthesis or breakdown of sphingolipids and phospholipids associated with lowered estimated insulin sensitivity and excessive lipolysis in early-lactating cows.

  12. Hostility among adolescents in Switzerland? multivariate relations between excessive media use and forms of violence.

    Science.gov (United States)

    Kuntsche, Emmanuel N

    2004-03-01

    To determine what kind of violence-related behavior or opinion is directly related to excessive media use among adolescents in Switzerland. A national representative sample of 4222 schoolchildren (7th- and 8th-graders; mean age 13.9 years) answered questions on the frequency of television-viewing, electronic game-playing, feeling unsafe at school, bullying others, hitting others, and fighting with others, as part of the Health Behaviour in School-Aged Children (HBSC) international collaborative study protocol. The Chi-square tests and multiple logistic regression analyses were applied to high-risk groups of adolescents. For the total sample, all bivariate relationships between television-viewing/electronic game-playing and each violence-related variable are significant. In the multivariate comparison, physical violence among boys ceases to be significant. For girls, only television-viewing is linked to indirect violence. Against the hypothesis, females' electronic game-playing only had a bearing on hitting others. Experimental designs are needed that take into account gender, different forms of media, and violence to answer the question of whether excessive media use leads to violent behavior. With the exception of excessive electronic game-playing among girls, this study found that electronic media are not thought to lead directly to real-life violence but to hostility and indirect violence.

  13. Variable collimator

    International Nuclear Information System (INIS)

    Richey, J.B.; McBride, T.R.; Covic, J.

    1979-01-01

    This invention describes an automatic variable collimator which controls the width and thickness of X-ray beams in X-ray diagnostic medical equipment, and which is particularly adapted for use with computerized axial tomographic scanners. A two-part collimator is provided which shapes an X-ray beam both prior to its entering an object subject to radiographic analysis and after the attenuated beam has passed through the object. Interposed between a source of radiation and the object subject to radiographic analysis is a first or source collimator. The source collimator causes the X-ray beam emitted by the source of radiation to be split into a plurality of generally rectangular shaped beams. Disposed within the source collimator is a movable aperture plate which may be used to selectively vary the thickness of the plurality of generally rectangular shaped beams transmitted through the source collimator. A second or receiver collimator is interposed between the object subject to radiographic analysis and a series of radiation detectors. The receiver collimator is disposed to receive the attenuated X-ray beams passing through the object subject to radiographic analysis. Located within the receiver collimator are a plurality of movable aperture plates adapted to be displaced relative to a plurality of fixed aperture plates for the purpose of varying the width and thickness of the attenuated X-ray beams transmitted through the object subject to radiographic analysis. The movable aperture plates of the source and receiver collimators are automatically controlled by circuitry which is provided to allow remote operation of the movable aperture plates

  14. [Excess mortality associated with influenza in Spain in winter 2012].

    Science.gov (United States)

    León-Gómez, Inmaculada; Delgado-Sanz, Concepción; Jiménez-Jorge, Silvia; Flores, Víctor; Simón, Fernando; Gómez-Barroso, Diana; Larrauri, Amparo; de Mateo Ontañón, Salvador

    2015-01-01

    An excess of mortality was detected in Spain in February and March 2012 by the Spanish daily mortality surveillance system and the «European monitoring of excess mortality for public health action» program. The objective of this article was to determine whether this excess could be attributed to influenza in this period. Excess mortality from all causes from 2006 to 2012 were studied using time series in the Spanish daily mortality surveillance system, and Poisson regression in the European mortality surveillance system, as well as the FluMOMO model, which estimates the mortality attributable to influenza. Excess mortality due to influenza and pneumonia attributable to influenza were studied by a modification of the Serfling model. To detect the periods of excess, we compared observed and expected mortality. In February and March 2012, both the Spanish daily mortality surveillance system and the European mortality surveillance system detected a mortality excess of 8,110 and 10,872 deaths (mortality ratio (MR): 1.22 (95% CI:1.21-1.23) and 1.32 (95% CI: 1.29-1.31), respectively). In the 2011-12 season, the FluMOMO model identified the maximum percentage (97%) of deaths attributable to influenza in people older than 64 years with respect to the mortality total associated with influenza (13,822 deaths). The rate of excess mortality due to influenza and pneumonia and respiratory causes in people older than 64 years, obtained by the Serfling model, also reached a peak in the 2011-2012 season: 18.07 and 77.20, deaths per 100,000 inhabitants, respectively. A significant increase in mortality in elderly people in Spain was detected by the Spanish daily mortality surveillance system and by the European mortality surveillance system in the winter of 2012, coinciding with a late influenza season, with a predominance of the A(H3N2) virus, and a cold wave in Spain. This study suggests that influenza could have been one of the main factors contributing to the mortality excess

  15. Investigation of excess thyroid cancer incidence in Los Alamos County

    International Nuclear Information System (INIS)

    Athas, W.F.

    1996-04-01

    Los Alamos County (LAC) is home to the Los Alamos National Laboratory, a U.S. Department of Energy (DOE) nuclear research and design facility. In 1991, the DOE funded the New Mexico Department of Health to conduct a review of cancer incidence rates in LAC in response to citizen concerns over what was perceived as a large excess of brain tumors and a possible relationship to radiological contaminants from the Laboratory. The study found no unusual or alarming pattern in the incidence of brain cancer, however, a fourfold excess of thyroid cancer was observed during the late-1980's. A rapid review of the medical records for cases diagnosed between 1986 and 1990 failed to demonstrate that the thyroid cancer excess had resulted from enhanced detection. Surveillance activities subsequently undertaken to monitor the trend revealed that the excess persisted into 1993. A feasibility assessment of further studies was made, and ultimately, an investigation was conducted to document the epidemiologic characteristics of the excess in detail and to explore possible causes through a case-series records review. Findings from the investigation are the subject of this report

  16. Investigation of excess thyroid cancer incidence in Los Alamos County

    Energy Technology Data Exchange (ETDEWEB)

    Athas, W.F.

    1996-04-01

    Los Alamos County (LAC) is home to the Los Alamos National Laboratory, a U.S. Department of Energy (DOE) nuclear research and design facility. In 1991, the DOE funded the New Mexico Department of Health to conduct a review of cancer incidence rates in LAC in response to citizen concerns over what was perceived as a large excess of brain tumors and a possible relationship to radiological contaminants from the Laboratory. The study found no unusual or alarming pattern in the incidence of brain cancer, however, a fourfold excess of thyroid cancer was observed during the late-1980`s. A rapid review of the medical records for cases diagnosed between 1986 and 1990 failed to demonstrate that the thyroid cancer excess had resulted from enhanced detection. Surveillance activities subsequently undertaken to monitor the trend revealed that the excess persisted into 1993. A feasibility assessment of further studies was made, and ultimately, an investigation was conducted to document the epidemiologic characteristics of the excess in detail and to explore possible causes through a case-series records review. Findings from the investigation are the subject of this report.

  17. Land-mobile satellite excess path loss measurements

    Science.gov (United States)

    Hess, G. C.

    1980-05-01

    An experiment conducted with the ATS-6 satellite to determine the additional path loss over free-space loss experienced by land-mobile communication links is described. This excess path loss is measured as a function of 1) local environment, 2) vehicle heading, 3) link frequency, 4) satellite elevation angle, and 5) street side. A statistical description of excess loss developed from the data shows that the first two parameters dominate. Excess path loss on the order of 25 dB is typical in urban situations, but decreases to under 10 dB in suburban/rural areas. Spaced antenna selection diversity is found to provide only a slight decrease (4 dB, typically) in the urban excess path loss observed. Level crossing rates are depressed in satellite links relative to those of Rayleigh-faded terrestrial links, but increases in average fade durations tend to offset that advantage. The measurements show that the excess path loss difference between 860-MHz links and 1550-MHz links is generally negligible.

  18. Twentieth century surge of excess adult male mortality

    Science.gov (United States)

    Beltrán-Sánchez, Hiram; Finch, Caleb E.; Crimmins, Eileen M.

    2015-01-01

    Using historical data from 1,763 birth cohorts from 1800 to 1935 in 13 developed countries, we show that what is now seen as normal—a large excess of female life expectancy in adulthood—is a demographic phenomenon that emerged among people born in the late 1800s. We show that excess adult male mortality is clearly rooted in specific age groups, 50–70, and that the sex asymmetry emerged in cohorts born after 1880 when male:female mortality ratios increased by as much as 50% from a baseline of about 1.1. Heart disease is the main condition associated with increased excess male mortality for those born after 1900. We further show that smoking-attributable deaths account for about 30% of excess male mortality at ages 50–70 for cohorts born in 1900–1935. However, after accounting for smoking, substantial excess male mortality at ages 50–70 remained, particularly from cardiovascular disease. The greater male vulnerability to cardiovascular conditions emerged with the reduction in infectious mortality and changes in health-related behaviors. PMID:26150507

  19. Response of hippocampal mossy fiber zinc to excessive glutamate release.

    Science.gov (United States)

    Takeda, Atsushi; Minami, Akira; Sakurada, Naomi; Nakajima, Satoko; Oku, Naoto

    2007-01-01

    The response of hippocampal mossy fiber zinc to excessive glutamate release was examined to understand the role of the zinc in excessive excitation in the hippocampus. Extracellular zinc and glutamate concentrations during excessive stimulation with high K(+) were compared between the hippocampal CA3 and CA1 by the in vivo microdialysis. Zinc concentration in the CA3 was more increased than that in the CA1, while glutamate concentration in the CA3 was less increased than that in the CA1. It is likely that more increase in extracellular zinc is linked with less increase in extracellular glutamate in the CA3. To see zinc action in mossy fiber synapses during excessive excitation, furthermore, 1mM glutamate was regionally delivered to the stratum lucidum in the presence of zinc or CaEDTA, a membrane-impermeable zinc chelator, and intracellular calcium signal was measured in the CA3 pyramidal cell layer. The persistent increase in calcium signal during stimulation with glutamate was significantly attenuated in the presence of 100 microM zinc, while significantly enhanced in the presence of 1mM CaEDTA. These results suggest that zinc released from mossy fibers attenuates the increase in intracellular calcium signal in mossy fiber synapses and postsynaptic CA3 neurons after excessive inputs to dentate granular cells.

  20. Use of Normothermic Default Humidifier Settings Causes Excessive Humidification of Respiratory Gases During Therapeutic Hypothermia.

    Science.gov (United States)

    Tanaka, Shoichiro; Iwata, Sachiko; Kinoshita, Masahiro; Tsuda, Kennosuke; Sakai, Sayaka; Saikusa, Mamoru; Shindo, Ryota; Harada, Eimei; Okada, Junichiro; Hisano, Tadashi; Kanda, Hiroshi; Maeno, Yasuki; Araki, Yuko; Ushijima, Kazuo; Sakamoto, Teruo; Yamashita, Yushiro; Iwata, Osuke

    2016-12-01

    Adult patients frequently suffer from serious respiratory complications during therapeutic hypothermia. During therapeutic hypothermia, respiratory gases are humidified close to saturated vapor at 37°C (44 mg/L) despite that saturated vapor reduces considerably depending on temperature reduction. Condensation may cause serious adverse events, such as bronchial edema, mucosal dysfunction, and ventilator-associated pneumonia during cooling. To determine clinical variables associated with inadequate humidification of respiratory gases during cooling, humidity of inspiratory gases was measured in 42 cumulative newborn infants who underwent therapeutic hypothermia. Three humidifier settings of 37-default (chamber outlet, 37°C; distal circuit, 40°C), 33.5-theoretical (chamber outlet, 33.5°C; distal circuit, 36.5°C), and 33.5-adjusted (optimized setting to achieve 36.6 mg/L using feedback from a hygrometer) were tested to identify independent variables of excessively high humidity >40.7 mg/L and low humidity <32.9 mg/L. The mean (SD) humidity at the Y-piece was 39.2 (5.2), 33.3 (4.1), and 36.7 (1.2) mg/L for 37-default, 33.5-theoretical, and 33.5-adjusted, respectively. The incidence of excessive high humidity was 10.3% (37-default, 31.0%; 33.5-theoretical, 0.0%; 33.5-adjusted, 0.0%), which was positively associated with the use of a counter-flow humidifier (p < 0.001), 37-default (compared with 33.5-theoretical and 33.5-adjusted, both p < 0.001) and higher fraction of inspired oxygen (p = 0.003). The incidence of excessively low humidity was 17.5% (37-default, 7.1%; 33.5-theoretical, 45.2%; 33.5-adjusted, 0.0%), which was positively associated with the use of a pass-over humidifier and 33.5-theoretical (both p < 0.001). All patients who used a counter-flow humidifier achieved the target gas humidity at the Y-piece (36.6 ± 0.5 mg/L) required for 33.5-adjusted with 33.5-theoretical. During cooling, 37-default is associated with

  1. Response of water vapour D-excess to land-atmosphere interactions in a semi-arid environment

    KAUST Repository

    Parkes, Stephen

    2016-06-30

    The stable isotopic composition of water vapour provides information about moisture sources and processes difficult to obtain with traditional measurement techniques. Recently, it has been proposed that the D-excess of water vapour can provide a diagnostic tracer of continental moisture recycling. However, D-excess exhibits a diurnal cycle that has been observed across a variety of ecosystems and may be influenced by a range of processes beyond regional-scale moisture recycling, including local evaporation (ET) fluxes. There is a lack of measurements of D-excess in evaporation (ET) fluxes, which has made it difficult to assess how ET fluxes modify the Dexcess in water vapour (dv). With this in mind, we employed a chamber-based approach to directly measure D-excess in ET (dET) fluxes. We show that ET fluxes imposed a negative forcing on the ambient vapour and could not explain the higher daytime dv values. The low dET observed here was sourced from a soil water pool that had undergone an extended drying period, leading to low D-excess in the soil moisture pool. A strong correlation between daytime dv and locally measured relative humidity was consistent with an oceanic moisture source, suggesting that remote hydrological processes were the major contributor to daytime dv variability. During the early evening, ET fluxes into a shallow nocturnal inversion layer caused a lowering of dv values near the surface. In addition, transient mixing of vapour with a higher D-excess from above the nocturnal inversion modified these values, causing large variability during the night. These results indicate dET can generally be expected to show

  2. Response of water vapour D-excess to land–atmosphere interactions in a semi-arid environment

    KAUST Repository

    Parkes, Stephen; McCabe, Matthew; Griffiths, Alan D.; Wang, Lixin; Chambers, Scott; Ershadi, Ali; Williams, Alastair G.; Strauss, Josiah; Element, Adrian

    2017-01-01

    The stable isotopic composition of water vapour provides information about moisture sources and processes difficult to obtain with traditional measurement techniques. Recently, it has been proposed that the D-excess of water vapour (d =δH-8× δO) can provide a diagnostic tracer of continental moisture recycling. However, D-excess exhibits a diurnal cycle that has been observed across a variety of ecosystems and may be influenced by a range of processes beyond regional-scale moisture recycling, including local evaporation (ET) fluxes. There is a lack of measurements of D-excess in evaporation (ET) fluxes, which has made it difficult to assess how ET fluxes modify the Dexcess in water vapour (d). With this in mind, we employed a chamber-based approach to directly measure D-excess in ET (d) fluxes. We show that ET fluxes imposed a negative forcing on the ambient vapour and could not explain the higher daytime d values. The low d observed here was sourced from a soil water pool that had undergone an extended drying period, leading to low D-excess in the soil moisture pool. A strong correlation between daytime d and locally measured relative humidity was consistent with an oceanic moisture source, suggesting that remote hydrological processes were the major contributor to daytime d variability. During the early evening, ET fluxes into a shallow nocturnal inversion layer caused a lowering of d values near the surface. In addition, transient mixing of vapour with a higher D-excess from above the nocturnal inversion modified these values, causing large variability during the night. These results indicate d can generally be expected to show large spatial and temporal variability and to depend on the soil moisture state. For long periods between rain events, common in semi-arid environments, ET would be expected to impose negative forcing on the surface d. Spatial and temporal variability of D-excess in ET fluxes therefore needs to be considered when using d to study

  3. Response of water vapour D-excess to land–atmosphere interactions in a semi-arid environment

    KAUST Repository

    Parkes, Stephen

    2017-01-27

    The stable isotopic composition of water vapour provides information about moisture sources and processes difficult to obtain with traditional measurement techniques. Recently, it has been proposed that the D-excess of water vapour (d =δH-8× δO) can provide a diagnostic tracer of continental moisture recycling. However, D-excess exhibits a diurnal cycle that has been observed across a variety of ecosystems and may be influenced by a range of processes beyond regional-scale moisture recycling, including local evaporation (ET) fluxes. There is a lack of measurements of D-excess in evaporation (ET) fluxes, which has made it difficult to assess how ET fluxes modify the Dexcess in water vapour (d). With this in mind, we employed a chamber-based approach to directly measure D-excess in ET (d) fluxes. We show that ET fluxes imposed a negative forcing on the ambient vapour and could not explain the higher daytime d values. The low d observed here was sourced from a soil water pool that had undergone an extended drying period, leading to low D-excess in the soil moisture pool. A strong correlation between daytime d and locally measured relative humidity was consistent with an oceanic moisture source, suggesting that remote hydrological processes were the major contributor to daytime d variability. During the early evening, ET fluxes into a shallow nocturnal inversion layer caused a lowering of d values near the surface. In addition, transient mixing of vapour with a higher D-excess from above the nocturnal inversion modified these values, causing large variability during the night. These results indicate d can generally be expected to show large spatial and temporal variability and to depend on the soil moisture state. For long periods between rain events, common in semi-arid environments, ET would be expected to impose negative forcing on the surface d. Spatial and temporal variability of D-excess in ET fluxes therefore needs to be considered when using d to study

  4. EXCESSIVE WEIGHT – MUSCLE DEPLETION PARADOX AND CARDIOVASCULAR RISK FACTORS IN OUTPATIENTS WITH INFLAMMATORY BOWEL DISEASE

    Directory of Open Access Journals (Sweden)

    Maria Izabel Siqueira de ANDRADE

    2015-03-01

    Full Text Available Background Evidence suggests a nutritional transition process in patients with inflammatory bowel disease. Obesity, which was once an uncommon occurrence in such patients, has grown in this population at the same prevalence rate as that found in the general population, bringing with it an increased risk of cardiovascular disease. Objective The aim of the present study was to determine the nutritional status and occurrence of cardiovascular risk factors in patients with inflammatory bowel disease. Methods A case-series cross-sectional study was conducted involving male and female adult outpatients with inflammatory bowel disease. Data were collected on demographic, socioeconomic, clinical and anthropometric variables as well as the following cardiovascular risk factors: sedentary lifestyle, excess weight, abdominal obesity, medications in use, comorbidities, alcohol intake and smoking habits. The significance level for all statistical tests was set to 5% (P< 0.05. Results The sample comprised 80 patients with inflammatory bowel disease, 56 of whom (70.0% had ulcerative colitis and 24 of whom (30.0% had Crohn's disease. Mean age was 40.3±11 years and the female genre accounted for 66.2% of the sample. High frequencies of excess weight (48.8% and abdominal obesity (52.5% were identified based on the body mass index and waist circumference, respectively, in both groups, especially among those with ulcerative colitis. Muscle depletion was found in 52.5% of the sample based on arm muscle circumference, with greater depletion among patients with Crohn’s disease (P=0.008. The most frequent risk factors for cardiovascular disease were a sedentary lifestyle (83.8%, abdominal obesity (52.5% and excess weight (48.8%. Conclusion The results of the complete anthropometric evaluation draw one’s attention to a nutritional paradox, with high frequencies of both - muscle depletion, as well as excess weight and abdominal obesity.

  5. Association between excess weight and beverage portion size consumed in Brazil

    Directory of Open Access Journals (Sweden)

    Ilana Nogueira Bezerra

    2018-02-01

    Full Text Available ABSTRACT OBJECTIVE To describe the beverage portion size consumed and to evaluate their association with excess weight in Brazil. METHODS We used data from the National Dietary Survey, which included individuals with two days of food record aged over 20 years (n = 24,527 individuals. The beverages were categorized into six groups: soft drink, 100% fruit juice, fruit drink, alcoholic beverage, milk, and coffee or tea. We estimated the average portion consumed for each group and we evaluated, using linear regression, the association between portion size per group and the variables of age, sex, income, and nutritional status. We tested the association between portion size and excess weight using Poisson regression, adjusted for age, sex, income, and total energy intake. RESULTS The most frequently consumed beverages in Brazil were coffee and tea, followed by 100% fruit juices, soft drinks, and milk. Alcoholic beverages presented the highest average in the portion size consumed, followed by soft drinks, 100% fruit juice, fruit drink, and milk. Portion size showed positive association with excess weight only in the soft drink (PR = 1.19, 95%CI 1.10–1.27 and alcoholic beverage groups (PR = 1.20, 95%CI, 1.11–1.29, regardless of age, sex, income, and total energy intake. CONCLUSIONS Alcoholic beverages and soft drinks presented the highest averages in portion size and positive association with excess weight. Public health interventions should address the issue of portion sizes offered to consumers by discouraging the consumption of large portions, especially sweetened and low nutritional beverages.

  6. Plutonium determination in solution with excess hydrofluoric acid

    International Nuclear Information System (INIS)

    Krtil, J.; Kuvik, V.; Spevackova, V.

    1975-01-01

    The determination is described of plutonium in solutions in the presence of fluoride ions resulting from the hydrolysis of PuF 6 . The method is based on reduction of Pu(VI) by excess of Fe(II) and on re-titration of Fe(II) with ceric salt. The effect of fluoride ions on plutonium determination was studied. It was found that a 3 mole excess of HF with respect to Pu decreased the results of Pu determination. The interference of fluoride ions was eliminated by a two-fold evaporation of the solution to be titrated with HNO 3 to dryness or by complex formation with boric arid. The amount of 20.50 mg Pu in the presence of a 10 mole excess of fluoride ions (17 mg HF) was determined with an error of +- 0.09 mg ). (author)

  7. Internet Addiction and Excessive Social Networks Use: What About Facebook?

    Science.gov (United States)

    Guedes, Eduardo; Sancassiani, Federica; Carta, Mauro Giovani; Campos, Carlos; Machado, Sergio; King, Anna Lucia Spear; Nardi, Antonio Egidio

    2016-01-01

    Facebook is notably the most widely known and used social network worldwide. It has been described as a valuable tool for leisure and communication between people all over the world. However, healthy and conscience Facebook use is contrasted by excessive use and lack of control, creating an addiction with severely impacts the everyday life of many users, mainly youths. If Facebook use seems to be related to the need to belong, affiliate with others and for self-presentation, the beginning of excessive Facebook use and addiction could be associated to reward and gratification mechanisms as well as some personality traits. Studies from several countries indicate different Facebook addiction prevalence rates, mainly due to the use of a wide-range of evaluation instruments and to the lack of a clear and valid definition of this construct. Further investigations are needed to establish if excessive Facebook use can be considered as a specific online addiction disorder or an Internet addiction subtype. PMID:27418940

  8. The excess in the hate discourse of the haters

    Directory of Open Access Journals (Sweden)

    Rebeca Recuero Rebs

    2017-11-01

    Full Text Available The article aims to identify and comprehend the marks of the excess present in the hate discourse of the haters. By using the power of social media’s information diffusion on the internet, the haters appropriate of such spaces to disseminate ideologies related to violence, intending to generate more hate. Among the strategies utilized by this group, there is the excess. However, it is necessary to understand the subject’s social and historical contexts and the meanings of their discourse in these environments. As the corpus, we start off the analysis from the attacks towards the actress Taís Araújo occurred on Facebook. As shown by the results, the excess is perceived on authority demonstrations, on the repetition of ideals and onto the search of values such as visibility, popularity (among participants of the networks and the media, authority and reputation (inside the hater’s group of belonging.elonging.

  9. Excessive computer game playing: evidence for addiction and aggression?

    Science.gov (United States)

    Grüsser, S M; Thalemann, R; Griffiths, M D

    2007-04-01

    Computer games have become an ever-increasing part of many adolescents' day-to-day lives. Coupled with this phenomenon, reports of excessive gaming (computer game playing) denominated as "computer/video game addiction" have been discussed in the popular press as well as in recent scientific research. The aim of the present study was the investigation of the addictive potential of gaming as well as the relationship between excessive gaming and aggressive attitudes and behavior. A sample comprising of 7069 gamers answered two questionnaires online. Data revealed that 11.9% of participants (840 gamers) fulfilled diagnostic criteria of addiction concerning their gaming behavior, while there is only weak evidence for the assumption that aggressive behavior is interrelated with excessive gaming in general. Results of this study contribute to the assumption that also playing games without monetary reward meets criteria of addiction. Hence, an addictive potential of gaming should be taken into consideration regarding prevention and intervention.

  10. Testing ATLAS diboson excess with dark matter searches at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Liew, Seng Pei [Department of Physics, University of Tokyo, Tokyo 113-0033 (Japan); Shirai, Satoshi [Deutsches Elektronen-Synchrotron (DESY), 22607 Hamburg (Germany)

    2015-11-27

    The ATLAS collaboration has recently reported a 2.6σ excess in the search for a heavy resonance decaying into a pair of weak gauge bosons. Only fully hadronic final states are being looked for in the analysis. If the observed excess really originates from the gauge bosons’ decays, other decay modes of the gauge bosons would inevitably leave a trace on other exotic searches. In this paper, we propose the use of the Z boson decay into a pair of neutrinos to test the excess. This decay leads to a very large missing energy and can be probed with conventional dark matter searches at the LHC. We discuss the current constraints from the dark matter searches and the prospects. We find that optimizing these searches may give a very robust probe of the resonance, even with the currently available data of the 8 TeV LHC.

  11. Testing ATLAS diboson excess with dark matter searches at LHC

    International Nuclear Information System (INIS)

    Liew, Seng Pei; Shirai, Satoshi

    2015-01-01

    The ATLAS collaboration has recently reported a 2.6σ excess in the search for a heavy resonance decaying into a pair of weak gauge bosons. Only fully hadronic final states are being looked for in the analysis. If the observed excess really originates from the gauge bosons’ decays, other decay modes of the gauge bosons would inevitably leave a trace on other exotic searches. In this paper, we propose the use of the Z boson decay into a pair of neutrinos to test the excess. This decay leads to a very large missing energy and can be probed with conventional dark matter searches at the LHC. We discuss the current constraints from the dark matter searches and the prospects. We find that optimizing these searches may give a very robust probe of the resonance, even with the currently available data of the 8 TeV LHC.

  12. Testing ATLAS diboson excess with dark matter searches at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Liew, Seng Pei [Tokyo Univ. (Japan). Dept. of Physics; Shirai, Satoshi [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2015-08-15

    The ATLAS collaboration has recently reported a 2.6σ excess in the search for a heavy resonance decaying into a pair of weak gauge bosons. Only fully hadronic final states are being looked for in the analysis. If the observed excess really originates from the gauge bosons' decays, other decay modes of the gauge bosons would inevitably leave a trace on other exotic searches. In this paper, we propose the use of the Z boson into a pair of neutrinos to test the excess. This decay leads to a very large missing energy and can be probed with conventional dark matter searches at the LHC. We discuss the current constraints from the dark matter searches and the prospects. We find that optimizing these searches may give a very robust probe of the resonance, even with the currently available data of the 8 TeV LHC.

  13. Internet Addiction and Excessive Social Networks Use: What About Facebook?

    Science.gov (United States)

    Guedes, Eduardo; Sancassiani, Federica; Carta, Mauro Giovani; Campos, Carlos; Machado, Sergio; King, Anna Lucia Spear; Nardi, Antonio Egidio

    2016-01-01

    Facebook is notably the most widely known and used social network worldwide. It has been described as a valuable tool for leisure and communication between people all over the world. However, healthy and conscience Facebook use is contrasted by excessive use and lack of control, creating an addiction with severely impacts the everyday life of many users, mainly youths. If Facebook use seems to be related to the need to belong, affiliate with others and for self-presentation, the beginning of excessive Facebook use and addiction could be associated to reward and gratification mechanisms as well as some personality traits. Studies from several countries indicate different Facebook addiction prevalence rates, mainly due to the use of a wide-range of evaluation instruments and to the lack of a clear and valid definition of this construct. Further investigations are needed to establish if excessive Facebook use can be considered as a specific online addiction disorder or an Internet addiction subtype.

  14. Financial Instability - a Result of Excess Liquidity or Credit Cycles?

    DEFF Research Database (Denmark)

    Heebøll-Christensen, Christian

    This paper compares the financial destabilizing effects of excess liquidity versus credit growth, in relation to house price bubbles and real economic booms. The analysis uses a cointegrated VAR model based on US data from 1987 to 2010, with a particulary focus on the period preceding the global...... financial crisis. Consistent with monetarist theory, the results suggest a stable money supply-demand relation in the period in question. However, the implied excess liquidity only resulted in financial destabilizing effect after year 2000. Meanwhile, the results also point to persistent cycles of real...... house prices and leverage, which appear to have been driven by real credit shocks, in accordance with post-Keynesian theories on financial instability. Importantly, however, these mechanisms of credit growth and excess liquidity are found to be closely related. In regards to the global financial crisis...

  15. Ethical implications of excessive cluster sizes in cluster randomised trials.

    Science.gov (United States)

    Hemming, Karla; Taljaard, Monica; Forbes, Gordon; Eldridge, Sandra M; Weijer, Charles

    2018-02-20

    The cluster randomised trial (CRT) is commonly used in healthcare research. It is the gold-standard study design for evaluating healthcare policy interventions. A key characteristic of this design is that as more participants are included, in a fixed number of clusters, the increase in achievable power will level off. CRTs with cluster sizes that exceed the point of levelling-off will have excessive numbers of participants, even if they do not achieve nominal levels of power. Excessively large cluster sizes may have ethical implications due to exposing trial participants unnecessarily to the burdens of both participating in the trial and the potential risks of harm associated with the intervention. We explore these issues through the use of two case studies. Where data are routinely collected, available at minimum cost and the intervention poses low risk, the ethical implications of excessively large cluster sizes are likely to be low (case study 1). However, to maximise the social benefit of the study, identification of excessive cluster sizes can allow for prespecified and fully powered secondary analyses. In the second case study, while there is no burden through trial participation (because the outcome data are routinely collected and non-identifiable), the intervention might be considered to pose some indirect risk to patients and risks to the healthcare workers. In this case study it is therefore important that the inclusion of excessively large cluster sizes is justifiable on other grounds (perhaps to show sustainability). In any randomised controlled trial, including evaluations of health policy interventions, it is important to minimise the burdens and risks to participants. Funders, researchers and research ethics committees should be aware of the ethical issues of excessively large cluster sizes in cluster trials. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is

  16. Fetal Programming of Obesity: Maternal Obesity and Excessive Weight Gain

    Directory of Open Access Journals (Sweden)

    Seray Kabaran

    2014-10-01

    Full Text Available The prevalence of obesity is an increasing health problem throughout the world. Maternal pre-pregnancy weight, maternal nutrition and maternal weight gain are among the factors that can cause childhood obesity. Both maternal obesity and excessive weight gain increase the risks of excessive fetal weight gain and high birth weight. Rapid weight gain during fetal period leads to changes in the newborn body composition. Specifically, the increase in body fat ratio in the early periods is associated with an increased risk of obesity in the later periods. It was reported that over-nutrition during fetal period could cause excessive food intake during postpartum period as a result of metabolic programming. By influencing the fetal metabolism and tissue development, maternal obesity and excessive weight gain change the amounts of nutrients and metabolites that pass to the fetus, thus causing excessive fetal weight gain which in turn increases the risk of obesity. Fetal over-nutrition and excessive weight gain cause permanent metabolic and physiologic changes in developing organs. While mechanisms that affect these organs are not fully understood, it is thought that the changes may occur as a result of the changes in fetal energy metabolism, appetite control, neuroendocrine functions, adipose tissue mass, epigenetic mechanisms and gene expression. In this review article, the effects of maternal body weight and weight gain on fetal development, newborn birth weight and risk of obesity were evaluated, and additionally potential mechanisms that can explain the effects of fetal over-nutrition on the risk of obesity were investigated [TAF Prev Med Bull 2014; 13(5.000: 427-434

  17. Excess europium content in Precambrian sedimentary rocks and continental evolution

    Science.gov (United States)

    Jakes, P.; Taylor, S. R.

    1974-01-01

    It is proposed that the europium excess in Precambrian sedimentary rocks, relative to those of younger age, is derived from volcanic rocks of ancient island arcs, which were the source materials for the sediments. Precambrian sedimentary rocks and present-day volcanic rocks of island arcs have similar REE patterns, total REE abundances, and excess Eu, relative to the North American shale composite. The present upper crustal REE pattern, as exemplified by that of sediments, is depleted in Eu, relative to chondrites. This depletion is considered to be a consequence of development of a granodioritic upper crust by partial melting in the lower crust, which selectively retains europium.

  18. Management of excessive gingival display: Lip repositioning technique

    Directory of Open Access Journals (Sweden)

    Upasana Sthapak

    2015-01-01

    Full Text Available The lips form the frame of a smile and define the esthetic zone. Excessive gingival display during smile is often referred to as "gummy smile". A successful management of excessive gingival display with lip repositioning procedure has shown excellent results. The procedure involves removing a strip of partial thickness mucosa from maxillary vestibule, then suturing it back to the lip mucosa at the level of mucogingival junction. This technique results in restricted muscle pull and a narrow vestibule, thereby reducing the gingival display. In this case gummy smile was treated by modification of Rubinstein and Kostianovsky′s surgical lip repositioning technique which resulted in a harmonious smile.

  19. Excess-pressure suppression device in a reactor container

    International Nuclear Information System (INIS)

    Nishio, Masahide

    1985-01-01

    Purpose: To reliably decrease the radioactivity of radioactive gases when they are released externally. Constitution: The exit of a gas exhaust pipe for discharging gases in a reactor container, on generation of an excess pressure in the reactor container upon loss of coolant accident, is adapted to be always fluided in the cooling tank. Then, the exhaust gases discharged in the cooling tank is realeased to the atmosphere. In this way, the excess pressure in the reactor container can be prevented previously and the radioactivity of the gases released externally is significantly reduced by the scrubbing effect. (Kamimura, M.)

  20. Thermophysical and excess properties of hydroxamic acids in DMSO

    International Nuclear Information System (INIS)

    Thakur, Piyush Kumar; Patre, Sandhya; Pande, Rama

    2013-01-01

    Graphical abstract: Excess molar volumes (V E ) vs mole fraction (x 2 ) of (A) N-o-tolyl-2-nitrobenzo- and (B) N-o-tolyl-4-nitrobenzo-hydroxamic acids in DMSO at different temperatures: ■, 298.15 K; ▪, 303.15 K; ▪, 308.15 K; ▪, 313.15 K; and ▪, 318.15 K. Highlights: ► ρ, n of the system hydroxamic acids in DMSO are reported. ► Apparent molar volume indicates superior solute–solvent interactions. ► Limiting apparent molar expansibility and coefficient of thermal expansion. ► Behaviour of this parameter suggest to hydroxamic acids act as structure maker. ► The excess properties have interpreted in terms of molecular interactions. -- Abstract: In this work, densities (ρ) and refractive indices (n) of N-o-tolyl-2-nitrobenzo- and N-o-tolyl-4-nitrobenzo-, hydroxamic acids have been determined for dimethyl sulfoxide (DMSO) as a function of their concentrations at T = (298.15, 303.15, 308.15, 313.15, and 318.15) K. These measurements were carried out to evaluate some important parameters, viz, molar volume (V), apparent molar volume (V ϕ ), limiting apparent molar volume (V ϕ 0 ), slope (S V ∗ ), molar refraction (R M ) and polarizability (α). The related parameters determined are limiting apparent molar expansivity (ϕ E 0 ), thermal expansion coefficient (α 2 ) and the Hepler constant (∂ 2 V ϕ 0 /∂T 2 ). Excess properties such as excess molar volume (V E ), deviations from the additivity rule of refractive index (n E ), excess molar refraction (R M E ) have also been evaluated. The excess properties were fitted to the Redlich–Kister equations to estimate their coefficients and standard deviations were determined. The variations of these excess parameters with composition were discussed from the viewpoint of intermolecular interactions in these solutions. The excess properties are found to be either positive or negative depending on the molecular interactions and the nature of solutions. Further, these parameters have been interpreted

  1. Real exchange rate persistence and the excess return puzzle

    DEFF Research Database (Denmark)

    Juselius, Katarina; Assenmacher, Katrin

    2017-01-01

    The PPP puzzle refers to the wide swings of nominal exchange rates around their long-run equilibrium values whereas the excess return puzzle represents the persistent deviation of the domestic-foreign interest rate differential from the expected change in the nominal exchange rate. Using the I(2......) cointegrated VAR model, much of the excess return puzzle disappears when an uncertainty premium in the foreign exchange market, proxied by the persistent PPP gap, is introduced. Self-reinforcing feedback mechanisms seem to cause the persistence in the Swiss-US parity conditions. These results support imperfect...

  2. Recommended treatment strategies for patients with excessive daytime sleepiness.

    Science.gov (United States)

    Rosenberg, Russell P

    2015-10-01

    Excessive daytime sleepiness (EDS) is a common and bothersome phenomenon. It can be associated with insufficient sleep syndrome, narcolepsy, idiopathic hypersomnia, obstructive sleep apnea, shift work disorder, Kleine-Levin syndrome, or Parkinson's disease. Once the underlying cause of the excessive sleepiness is determined, clinicians must select the most appropriate behavioral and pharmacologic interventions to reduce daytime sleepiness, alleviate other symptoms, improve functioning, and ensure the safety of patients and those around them. Patient history, adverse effects, and efficacy in specific conditions should be considered in pharmacologic treatment options for patients with EDS. © Copyright 2015 Physicians Postgraduate Press, Inc.

  3. Changes in Blood Components in Aphtha Patients with Excess Heat

    OpenAIRE

    Qin, Lu; Li, Yan; Jiao, Yifeng; Fu, Danqing; Ye, Li; Ji, Jinjun; Xie, Guanqun; Fan, Yongsheng; Xu, Li

    2016-01-01

    “Superior heat” is a popularization expression in TCM heat syndrome and has no counterpart in the modern medical system concept. Oral ulcer is considered to be a kind of clinical manifestation of “superior heat.” Aphtha is a common and frequently occurring disease, which can be divided into excess heat and Yin deficiency. The aphtha of excess heat manifests the syndromes of acute occurrence, severe local symptoms, obvious swelling and pain, red tongue, yellow coating, and fast-powerful pulse....

  4. Simplified Production of Organic Compounds Containing High Enantiomer Excesses

    Science.gov (United States)

    Cooper, George W. (Inventor)

    2015-01-01

    The present invention is directed to a method for making an enantiomeric organic compound having a high amount of enantiomer excesses including the steps of a) providing an aqueous solution including an initial reactant and a catalyst; and b) subjecting said aqueous solution simultaneously to a magnetic field and photolysis radiation such that said photolysis radiation produces light rays that run substantially parallel or anti-parallel to the magnetic field passing through said aqueous solution, wherein said catalyst reacts with said initial reactant to form the enantiomeric organic compound having a high amount of enantiomer excesses.

  5. Metronome Cueing of Walking Reduces Gait Variability after a Cerebellar Stroke

    OpenAIRE

    Wright, Rachel L.; Bevins, Joseph W.; Pratt, David; Sackley, Catherine M.; Wing, Alan M.

    2016-01-01

    Cerebellar stroke typically results in increased variability during walking. Previous research has suggested that auditory cueing reduces excessive variability in conditions such as Parkinson's disease and post-stroke hemiparesis. The aim of this case report was to investigate whether the use of a metronome cue during walking could reduce excessive variability in gait parameters after a cerebellar stroke. An elderly female with a history of cerebellar stroke and recurrent falling undertook th...

  6. A espirometria na avaliação pré e pós-transplante de medula óssea Pre-operative and post-operative spirometry in bone marrow transplant patients

    Directory of Open Access Journals (Sweden)

    Eliane Viana Mancuzo

    2007-02-01

    Full Text Available OBJETIVO: Analisar os resultados da espirometria de pacientes submetidos a transplante de medula óssea e verificar sua importância na detecção de complicações pulmonares e sua correlação com a evolução dos pacientes. MÉTODOS:Foram analisados retrospectivamente os resultados da espirometria em 120 pacientes, maiores de doze anos, de ambos os sexos, e comparados com o tipo de transplante de medula óssea, doença de base, sorologia para citomegalovírus, fonte de células para o transplante, tabagismo, infecção pulmonar, doença pulmonar prévia, duração da doença hematológica, quimioterapia utilizada, regime de condicionamento, doença do enxerto contra o hospedeiro aguda e crônica e óbito. RESULTADOS: Dezesseis pacientes apresentaram alterações da espirometria antes do transplante, sendo 5% com obstrução pura, 5,8% com restrição pura e 2,5% com obstrução com redução da capacidade vital. Após o transplante 29 pacientes apresentaram alterações desses exames. A chance de alteração da espirometria foi maior nos pacientes com doença do enxerto contra o hospedeiro aguda (p = 0,02, idade menor que 30 anos (p = 0,02, sexo feminino (p = 0,02 e naqueles que receberam células tronco (p = 0,01. As presenças de doença pulmonar prévia e doença do enxerto contra o hospedeiro crônica associaram-se com aumento da mortalidade. Alterações prévias da espirometria não estiveram relacionadas com o óbito pós-transplante. CONCLUSÃO: As alterações detectadas na espirometria não foram capazes de predizer a ocorrência de complicações pulmonares e óbito pós-transplantes. Também não foram determinantes para a não realização do procedimento. A espirometria simples realizada na avaliação desses pacientes parece ter pouca importância prática.OBJECTIVE: To analyze the spirometry findings in patients undergoing bone marrow transplant, determining the importance of such findings in predicting postoperative pulmonary

  7. Analysis of Gambling in the Media Related to Screens: Immersion as a Predictor of Excessive Use?

    Science.gov (United States)

    Rémond, Jean-Jacques; Romo, Lucia

    2018-01-02

    This study investigates the intricacies between the player interface proposed by the screens, (in particular on smartphone applications or in video games) and gambling. Recent research indicates connections between "immersion" and excessive screen practice. We want to understand the causal-effects between online gambling and the "immersion" variable and understand their relationship and its contingencies. This article empirically investigates whether and how it is possible to observe immersion with its sub-dimensions in gambling on different screens. The objective of this study was to analyze: (1) the costs and benefits associated with gambling practice on screens (2) the link between gambling practice and screen practice (video game, Internet, mobile screen); (3) to observe the propensity to immersion for individuals practicing gambling on screens; and (4) to examine the comorbidities and cognitive factors associated with the practice of gambling on screen. A total of 432 adults (212 men, 220 women), recruited from Ile-de-France (France), responded to a battery of questionnaires. Our study suggests that immersion variables make it possible to understand the cognitive participation of individuals towards screens in general, the practice of gambling on screens and the excessive practice of screens.

  8. Excess mortality in persons with severe mental disorders

    DEFF Research Database (Denmark)

    Liu, Nancy H; Daumit, Gail L; Dua, Tarun

    2017-01-01

    Excess mortality in persons with severe mental disorders (SMD) is a major public health challenge that warrants action. The number and scope of truly tested interventions in this area remain limited, and strategies for implementation and scaling up of programmes with a strong evidence base...

  9. Metallicity and ultraviolet excesses of late main sequence stars

    International Nuclear Information System (INIS)

    Suchkov, A.A.; Marsakov, V.A.; Shevelev, Yu.G.

    1987-01-01

    The comparison of the characteristics of ultraviolet (UV) excesses δ(U-B) and metallicity [Fe/H] distributions of F, G, and K dwarfs reveals a number of discrepancies. It is shown that they can be eliminated if we assume that UV excesses of K and late G dwarfs, and [Fe/H] values from detailed analysis for F dwarfs are underestimated. Such an assumption enables to account for low values of for F, K and late G dwarfs, and for the difference of the free terms in the metallicity - UV-excess relation for these stars as compared to early G dwarfs. In this case the F5-F9 dwarfs turn out to be more metal-rich (by 0.1 in [Fe/H]) than G and K dwarfs, and the metallicity of the Hyades cluster turns out to be larger than the solar one, [Fe/H] Hyades =+0.1. The ''conditional'' metallicity - UV-excess calibrations are obtained for four groups of main-sequence stars: F5-F9, G0-G4, G5-G9, K0-K5

  10. High‑risk of obstructive sleep apnea and excessive daytime ...

    African Journals Online (AJOL)

    Background: The burden of obstructive sleep apnea among commercial drivers in Nigeria is not known. Aim: To assess the prevalence of high risk of obstructive sleep apnea (OSA) and excessive daytime sleepiness (EDS) among intra‑city commercial drivers. Setting and Design: A descriptive cross‑sectional study in three ...

  11. Disposition of excess weapons plutonium from dismantled weapons

    International Nuclear Information System (INIS)

    Jardine, L.J.

    1997-01-01

    With the end of the Cold War and the implementation of various nuclear arms reduction agreements, US and Russia have been actively dismantling tens of thousands of nuclear weapons. As a result,large quantities of fissile materials, including more than 100 (tonnes?) of weapons-grade Pu, have become excess to both countries' military needs. To meet nonproliferation goals and to ensure the irreversibility of nuclear arms reductions, this excess weapons Pu must be placed in secure storage and then, in timely manner, either used in nuclear reactors as fuel or discarded in geologic repositories as solid waste. This disposition in US and Russia must be accomplished in a safe, secure manner and as quickly as practical. Storage of this Pu is a prerequisite to any disposition process, but the length of storage time is unknown. Whether by use as fuel or discard as solid waste, disposition of that amount of Pu will require decades--and perhaps longer, if disposition operations encounter delays. Neither US nor Russia believes that long-term secure storage is a substitute for timely disposition of excess Pu, but long-term, safe, secure storage is a critical element of all excess Pu disposition activities

  12. The effects of obesity, smoking, and excessive alcohol intake on ...

    African Journals Online (AJOL)

    The effects of obesity, smoking, and excessive alcohol intake on healthcare expenditure in a comprehensive medical scheme. ... South African Medical Journal ... a body mass index (BMI) of 30 - 35 kg/m2 averaged R2 300 (11%) higher annual medical expenditure in the year 2010 than never-smokers with a BMI <30 kg/m2.

  13. Hjertestop associeret med syndrome of apparent mineralocorticoid excess

    DEFF Research Database (Denmark)

    Meldgaard-Nielsen, Anne; Laugesen, Esben; Poulsen, Per Løgstrup

    2014-01-01

    Ventricular fibrillation is an unknown complication to the syndrome of apparent mineralocorticoid excess (SAME). This case report describes a young woman admitted with hypo-kalaemia and hypertension. Concentrations of both P-renin and P-aldosterone were low and urinary steroid metabolites revealed...

  14. Stress and emotional problems during pregnancy and excessive infant crying

    NARCIS (Netherlands)

    van der Wal, Marcel F.; van Eijsden, Manon; Bonsel, Gouke J.

    2007-01-01

    OBJECTIVE: There is evidence that stress and emotional problems during pregnancy are related to adverse health outcomes of the child at birth and in later life. The aim of this study was to determine the association between stress and emotional problems during pregnancy and excessive infant crying.

  15. Fusion reaction using low energy neutron-excess nucleus beam

    International Nuclear Information System (INIS)

    Fukuda, Tomokazu

    1994-01-01

    The present state and the plan of the experiment of measuring the fusion reaction near barriers by using neutron-excess nucleus beam, which has been advanced at RIKEN are reported. One of the purposes of this experiment is the feasibility investigation of the fusion reaction by using neutron-excess nuclei, which is indispensable for synthesizing superheavy elements. It is intended to systematically explore some enhancing mechanism in the neutron-excess nuclei which are unfavorable in beam intensity. This research can become the good means to prove the dynamic behavior of the neutrons on the surfaces of nuclei in reaction. The fusion reaction of 27 Al + Au was measured by using the stable nucleus beam of 27 Al, and the results are shown. In order to know the low energy fusion reaction of 11 Li and 11 Be which are typical halo nuclei, the identification by characteristic α ray of composite nuclei is carried out in 7,9,11 Li + 209 Bi and 9,10,11 Be + 208 Pb. A new detector having high performance, New MUSIC, is being developed. As the experiment by using this detector, the efficient measurement of the fusion reaction by using heavy neutron-excess nuclei up to Ni is considered. An example of 8 Li + α → 11 B + n reaction for celestial body physics is mentioned. (K.I.)

  16. excess molar volumes, and refractive index of binary mixtures

    African Journals Online (AJOL)

    Preferred Customer

    because (a) water molecules have hydroxyl group which can make stronger hydrogen bonding than methanol and (b) water molecules and glycerol have suitable kinetic energy for bulk volumes at high temperature. Thus, the mixture of glycerol + water have big excess molar volume than methanol. The hydrogen bonding ...

  17. Excessive crying: behavioral and emotional regulation disorder in infancy

    Directory of Open Access Journals (Sweden)

    Joon Sik Kim

    2011-06-01

    Full Text Available In the pediatric literature, excessive crying has been reported solely in association with 3-month colic and is described, if at all, as unexplained crying and fussing during the first 3 months of life. The bouts of crying are generally thought to be triggered by abdominal colic (over-inflation of the still immature gastrointestinal tract, and treatment is prescribed accordingly. According to this line of reasoning, excessive crying is harmless and resolves by the end of the third month without long-term consequences. However, there is evidence that it may cause tremendous distress in the mother&#8211;infant relationship, and can lead to disorders of behavioral and emotional regulation at the toddler stage (such as sleep and feeding disorders, chronic fussiness, excessive clinginess, and temper tantrums. Early treatment of excessive crying focuses on parent&#8211;infant communication, and parent-infant interaction in the context of soothing and settling the infant to sleep is a promising approach that may prevent later behavioral and emotional disorders in infancy.

  18. The decline in winter excess mortality in The Netherlands

    NARCIS (Netherlands)

    Kunst, A. E.; Looman, C. W.; Mackenbach, J. P.

    1991-01-01

    In most countries, numbers of deaths rise considerably during the winter season. This winter excess in mortality has, however, been declining during recent decades. The causes of this decline are hardly known. This paper attempts to derive a number of hypotheses on the basis of a detailed

  19. Towards an artificial therapy assistant: Measuring excessive stress from speech

    NARCIS (Netherlands)

    van der Sluis, Frans; van den Broek, Egon; Dijkstra, Ton; Traver, V.; Fred, A.; Filipe, J.; Gamboa, H.

    2011-01-01

    The measurement of (excessive) stress is still a challenging endeavor. Most tools rely on either introspection or expert opinion and are, therefore, often less reliable or a burden on the patient. An objective method could relieve these problems and, consequently, assist diagnostics. Speech was

  20. Do dividend shocks affect excess returns? An experimental study

    Directory of Open Access Journals (Sweden)

    Draganac Dragana

    2017-01-01

    Full Text Available The dividend announcement of a company is an informational event that can cause underreaction, momentum, overreaction, post-dividend announcement drift, and mean reversion. It is the uncertainty surrounding dividend announcements that leads to such behavioural phenomena. Most authors consider that underreaction occurs after dividend shocks because new information about the dividend is being slowly and gradually built into the stock price. The effect of dividend shocks is often reflected in excess returns, which can last up to one year after the shock. The experiment described in this paper tests whether statistically significant excess returns are realized after a shock dividend announcement. Participants trade with the stocks of two companies, which only differ by dividend-generating stochastic process. The dividend process of Company 2 is a Merton-style jump-diffusion process (consisting of two parts: Brownian motion and Poisson jump, while the dividend process of Company 1 contains only the Brownian motion component. Statistically significant excess returns are expected when trading with Company 2 stocks. An autoregressive model is applied in order to test this hypothesis. The conclusion is that a dividend shock is followed by statistically significant excess returns in 20 of the 22 experiments, which implies that markets are inefficient after sudden and large changes in dividends. Underreaction and discount rate effects are identified.