WorldWideScience

Sample records for evaluations joint evaluation

  1. The Case for a Joint Evaluation

    Science.gov (United States)

    2017-01-01

    The Capstone Concept of Joint Operations stresses that “the strength of any Joint Force has always been the combining of unique Service...order. Status Quo of Service Evaluations Across the Services, officers’ careers generally begin with a focus on entry- level technical, managerial ...would retain full control of their current evalu- ation systems. However, the Services’ evaluation systems and information would be fed directly

  2. Radiological evaluation of the acromioclavicular joint

    International Nuclear Information System (INIS)

    Vaeaetaeinen, U.; Maekelae, A.; Pirinen, A.

    1991-01-01

    X-ray measurement of the acromioclavicular (AC) joint may cause difficulties because of different projections and the lack of a reproducible measurement. In order to find the ideal measurement to estimate the state of the AC joint, 28 healthy adult volunteers were X-rayed. The least vulnerable measurement for errors in projection was the distance between the coracoid process and the upper part of the clavicle. The effect of stress was evaluated; the range of normal AC joint laxity was determined as 3 mm. (orig.)

  3. Radiological evaluation of the acromioclavicular joint

    Energy Technology Data Exchange (ETDEWEB)

    Vaeaetaeinen, U.; Maekelae, A. (Kuopio Univ. Central Hospital (Finland). Dept. of Surgery); Pirinen, A. (Kuopio Univ. Central Hospital (Finland). Dept. of Radiology)

    1991-02-01

    X-ray measurement of the acromioclavicular (AC) joint may cause difficulties because of different projections and the lack of a reproducible measurement. In order to find the ideal measurement to estimate the state of the AC joint, 28 healthy adult volunteers were X-rayed. The least vulnerable measurement for errors in projection was the distance between the coracoid process and the upper part of the clavicle. The effect of stress was evaluated; the range of normal AC joint laxity was determined as 3 mm. (orig.).

  4. Evaluation of Rock Joint Coefficients

    Science.gov (United States)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.

  5. The European-Japanese joint programme on neutron data evaluation

    International Nuclear Information System (INIS)

    Campbell, C.G.

    1983-01-01

    Following an initiative by the NEA Committee on Reactor Physics (NEACRP) at their meeting in September 1980, the NEA Steering Committee approved the setting up of a joint European-Japanese Programme on Neutron Data Evaluations. A Scientific Co-ordinating Group was formed to determine the content of the Joint Evaluated File (JEF) and to co-ordinate work in national research organisations associated with the periodic revisions to this library. The NEA Data Bank is taking care of the secretariat functions of the Programme and will also, among other things, assemble and maintain the Joint Evaluated File (JEF). The plans are to release a first version of the file at the end of 1982, followed by a period of re-evaluations and benchmark testing, which will lead to the release of a second version at the end of 1985. The availability of the file will be restricted to the member countries of the NEA Data Bank. (Auth.)

  6. Evaluation of traction stirrup distraction technique to increase the joint space of the shoulder joint in the dog: A cadaveric study.

    Science.gov (United States)

    Devesa, V; Rovesti, G L; Urrutia, P G; Sanroman, F; Rodriguez-Quiros, J

    2015-06-01

    The objective of this study was to evaluate technical feasibility and efficacy of a joint distraction technique by traction stirrup to facilitate shoulder arthroscopy and assess potential soft tissue damage. Twenty shoulders were evaluated radiographically before distraction. Distraction was applied with loads from 40 N up to 200 N, in 40 N increments, and the joint space was recorded at each step by radiographic images. The effects of joint flexion and intra-articular air injection at maximum load were evaluated. Radiographic evaluation was performed after distraction to evaluate ensuing joint laxity. Joint distraction by traction stirrup technique produces a significant increase in the joint space; an increase in joint laxity could not be inferred by standard and stress radiographs. However, further clinical studies are required to evaluate potential neurovascular complications. A wider joint space may be useful to facilitate arthroscopy, reducing the likelihood for iatrogenic damage to intra-articular structures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Magnetic resonance imaging-based temporomandibular joint space evaluation in temporomandibular disorders

    Energy Technology Data Exchange (ETDEWEB)

    Nah, Kyung Soo [Pusan National Univ. College of Dentistry, Pusan (Korea, Republic of)

    2007-03-15

    Disc and condylar position were observed on MRIs of temporomandibular joint disorder patients and condylar position agreement between MRI and tranascranal radiography was evaluated. MRI and transcranial radiographs of both TM joints from 67 patients with temporomandibular disorder were used. On MRI, the position and shape of disc and condylar position as anterior, middle, posterior was evaluated at medial, center, and lateral views. On transcranial radiographs, condylar position was evaluated using the shortest distance from condyle to fossa in anterior, superior, and posterior directions. 1. On MRI, 96 joints (71.6%) of 134 had anterior disc dispalcement with reduction and 38 joints (28.4%) without reduction. 2. Fourteen (14.6%) of 96 reducible joints showed anterior condylar position. 19 (19.8%) showed central position, 63 joints (65.6%) showed posterior position. Two joints (5.3%) of 38 non-reducible joints showed anterior condylar position, while 9 (23.7%) showed central position, and 27 (71.1%)-posterior position. 3. In 85 joints (63.4%) of 134, the transcranial condylar position agreed with that of the central MRI view, 10 joints (7.5%) with that of medial, 16 joints (11.6%) with that of lateral, and 23 joints (17.2%) disagreed with that of MRI. On MRI, most of the reducible and non-reducible joints showed posterior condylar position. Transcranial radiographs taken with machine designed for TMJ had better agreement of condylar position with that of MRI. Extremely narrow joint spaces or very posterior condylar positions observed on transcranial radiographs had a little more than fifty percent agreement with those of MRIs.

  8. Creep behavior evaluation of welded joint

    International Nuclear Information System (INIS)

    Susei, Shuzo; Matsui, Shigetomo; Mori, Eisuke; Shimizu, Shigeki; Satoh, Keisuke.

    1980-01-01

    In the creep design of high temperature structural elements, it is necessary to grasp the creep performance of joints as a whole, paying attention to the essential lack of uniformity between the material qualities of parent metals and welds. In this study, the factors controlling the creep performance of butt welded joints were investigated theoretically, when they were subjected to lateral tension and longitudinal tension. It was clarified that the rupture time in the case of laterally pulled joints was determined by the ratio of the creep rupture times of weld metals and parent metals, and the rupture time in the case of longitudinally pulled joints was determined by the ratio of the creep rupture times and the ratio of the creep strain rates of weld metals and parent metals. Moreover, when the joints of the former ratio less than 1 and the latter ratio larger than 1 were investigated experimentally, the rupture time in the case of laterally pulled joints was affected by the relative thickness, and when the relative thickness was large, the theoretical and the experimental values coincided, but the relative thickness was small, the theoretical values gave the evaluation on safe side as compared with the experimental values due to the effect of restricting deformation. In the case of longitudinally pulled joints, the theoretical and the experimental values coincided relatively well. The diagram of classifying the creep performance of welded joints was proposed. (Kako, I.)

  9. Consideration on evaluation of internal pressure creep rupture for tube with circumferential joint

    International Nuclear Information System (INIS)

    Nagato, Kotaro; Satoh, Keisuke

    1983-01-01

    The behavior of internal pressure creep rupture of the thin-walled cylinders with circumferential joints is affected by the combination of creep characteristics of parent materials and weld metals. In particular, the compatibility of the creep strain rate of parent materials and weld metals becomes an important controlling factor. The behavior of internal pressure creep of the welded parts in circumferential joint cylinders can be evaluated simply with the uniaxial creep data of parent materials and weld metals, considering it by approximately substituting with the creep behavior of a uniaxial longitudinal joint. The method of evaluation is, first, to analyze the breaking behavior of uniaxial longitudinal joints using the uniaxial creep characteristic values of parent materials and weld metals, and next, by combining the equation for the relation between the rupture times of uniaxial creep and internal pressure creep with the analyzed breaking behavior of uniaxial joints, the internal pressure creep rupture behavior of the cylinders with circumferential joints can be evaluated. The internal pressure creep behavior of the thin-walled cylinders with circumferential joints, their rupture life and the uniaxial creep rupture life of longitudinal joints, and the examination of Hastelloy X cylinders are reported. (Kako, I.)

  10. Clinical evaluation of joint scintigraphy in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Shimabukuro, Kunisada; Sakata, Hiromichi; Shirono, Kazuo; Nakajo, Masataka; Shinohara, Shinji

    1983-01-01

    Pertechnetate (sup(99m)TcO 4 - ) joint scintigraphy was performed on 45 patients with rheumatoid arthritis, 3 with nonspecific arthritis and 6 normal subjects. 1) The sites of radioisotopic accumulation were generally in agreement with those of clinical involvement in rheumatoid arthritis. 2) By analysis of build-up curves in the wrist joint, tracer was found to be concentrated more rapidly in rheumatoid arthritis (T 1/2 = 0.67 min.) than in nonspecific arthritis (T 1/2 = 2.66 min.) 3) The degree of radioisotopic accumulation correlated well with the value of CRP and erythrocyte sedimentation rate. It could be cosidered that pertechnetate joint scintigraphy is useful for clinical evaluation of rheumatoid arthritis. (author)

  11. Patellofemoral joint motion: Evaluation by ultrafast computed tomography

    International Nuclear Information System (INIS)

    Stanford, W.; Phelan, J.; Kathol, M.H.; Rooholamini, S.A.; El-Khoury, G.Y.; Palutsis, G.R.; Albright, J.P.

    1988-01-01

    Patellofemoral maltracking is a recognized cause of peripatellar pain. Clinicians currently rely on observation, palpation, and static radiographic images to evaluate the symptomatic patient. Ultrafast computed tomography (ultrafast CT) offers objective observations of the dynamic influences of muscle contraction on the patellofemoral joint as the knee is actively moved through a range of motion from 90 0 C flexion of full extension. This study reports our initial observations and establishes a range of normal values so that patients with a clinical suspicion of patellar maltracking may be evaluated. (orig./GDG)

  12. Patellofemoral joint motion: Evaluation by ultrafast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Stanford, W.; Phelan, J.; Kathol, M.H.; Rooholamini, S.A.; El-Khoury, G.Y.; Palutsis, G.R.; Albright, J.P.

    1988-10-01

    Patellofemoral maltracking is a recognized cause of peripatellar pain. Clinicians currently rely on observation, palpation, and static radiographic images to evaluate the symptomatic patient. Ultrafast computed tomography (ultrafast CT) offers objective observations of the dynamic influences of muscle contraction on the patellofemoral joint as the knee is actively moved through a range of motion from 90/sup 0/C flexion of full extension. This study reports our initial observations and establishes a range of normal values so that patients with a clinical suspicion of patellar maltracking may be evaluated. (orig./GDG).

  13. Evaluation of the patellofemoral joint with simple RX and TAC

    International Nuclear Information System (INIS)

    Mantilla M, Isabel; Villa R, Alfredo

    1992-01-01

    The different radiological and tomographic methods used in the evaluation o the patellofemoral joint are described, comparing the sensitivity of the different measurements and their correlation, and their relationship with the clinical presentation of the patient. The data were obtained from a comparative study in which radiological and tomographic studies were performed to a group of patients whose symptoms were related to the patellofemoral joints

  14. 77 FR 74279 - Agency Information Collection (VA/DOD Joint Disability Evaluation Board Claim): Activity under...

    Science.gov (United States)

    2012-12-13

    ... Joint Disability Evaluation Board Claim): Activity under OMB Review AGENCY: Veterans Benefits... . Please refer to ``OMB Control No. 2900-0704.'' SUPPLEMENTARY INFORMATION: Title: VA/DOD Joint Disability Evaluation Board Claim, VA Form 21- 0819. OMB Control Number: 2900-0704. Type of Review: Extension of a...

  15. An evaluation of charity care for tax-exempt hospitals engaging in joint ventures.

    Science.gov (United States)

    Smith, Pamela C

    2006-01-01

    The study examines whether the level of charity care and financial stability contribute to a nonprofit hospital's motivation for partnering with a for-profit hospital through a joint venture. The Internal Revenue Service (IRS) has heightened its scrutiny of joint ventures within the health care sector. Considering recent calls to investigate the merit of the tax-exempt status of hospitals engaged in joint ventures, this research will assist policy makers in the evaluation of nonprofit hospitals. Constituents will continue to question whether joint ventures contribute to a reduced focus on charitable activities. Results indicate that the propensity to engage in a joint venture significantly increases with increased levels of charity care. Furthermore, nonprofit hospitals with lower profitability are more likely to engage in joint ventures. These results are useful to policy makers when evaluating the level of charity care provided by hospitals seeking alternative strategic alliances. Considering many critics allege hospitals are reducing the provision of charity care to the community, it is imperative for management to be conscious of the impact of joint ventures on the provision of charity care.

  16. JUPITER PROJECT - JOINT UNIVERSAL PARAMETER IDENTIFICATION AND EVALUATION OF RELIABILITY

    Science.gov (United States)

    The JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) project builds on the technology of two widely used codes for sensitivity analysis, data assessment, calibration, and uncertainty analysis of environmental models: PEST and UCODE.

  17. [A primary application and evaluation of temporomandibular joint replacement with stock prosthesis].

    Science.gov (United States)

    Zhang, Xiao-hu; Chen, Min-jie; Qiu, Ya-ting; Yang, Chi

    2012-06-01

    To evaluate the effect of total joint replacement in treatment of temporomandibular joint(TMJ) osteoarthropathy with stock prostheses. Six female patients involving 10 joints (2 unilateral and 4 bilateral), with an average age of 59 years old, were involved in this study. Three patients (5 joints) were diagnosed as internal derangement in V stage depending on MRI, 3D-CT findings and clinical characteristics. The other 3 patients (5 joints) had histories of failed temporomandibular joint operation using costochondral graft or temporalis fascial flap. The maximal mouth opening was 1.9 cm on average (range, 1.0 to 2.9cm). All the joints were replaced with Biomet standard prosthesis under general anesthesia. The follow-up period was from 7 to 49 months (average, 17.5 months). All the operations were successfully performed. Heterotopic ossification happened in a bilateral case 1 year postoperatively. One patient with bilateral joint disease complained of severe uncomfortable feeling in the region of the ears and the temples, although there was no significant positive signs according to an ENT examination. Pain relief of the joint and mouth opening improvement were significant in 4 patients. No failure was noted secondary to infection or loosening of the prostheses. The occlusal relationship kept stable postoperatively in all cases. Total TMJ joint replacement with standard prosthesis is a good choice for TMJ reconstruction. It can significantly reduce joint pain and the mouth opening limitation resulted from osteoarthritis. Long-term result remains to be evaluated based on a long-term follow-up.

  18. Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel Part II: Plate bending test and proposal of a simplified evaluation method

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Masanori, E-mail: ando.masanori@jaea.go.jp; Takaya, Shigeru, E-mail: takaya.shigeru@jaea.go.jp

    2016-12-15

    Highlights: • Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel is proposed. • A simplified evaluation method is also proposed for the codification. • Both proposed evaluation method was validated by the plate bending test. • For codification, the local stress and strain behavior was analyzed. - Abstract: In the present study, to develop an evaluation procedure and design rules for Mod.9Cr-1Mo steel weld joints, a method for evaluating the creep-fatigue life of Mod.9Cr-1Mo steel weld joints was proposed based on finite element analysis (FEA) and a series of cyclic plate bending tests of longitudinal and horizontal seamed plates. The strain concentration and redistribution behaviors were evaluated and the failure cycles were estimated using FEA by considering the test conditions and metallurgical discontinuities in the weld joints. Inelastic FEA models consisting of the base metal, heat-affected zone and weld metal were employed to estimate the elastic follow-up behavior caused by the metallurgical discontinuities. The elastic follow-up factors determined by comparing the elastic and inelastic FEA results were determined to be less than 1.5. Based on the estimated elastic follow-up factors obtained via inelastic FEA, a simplified technique using elastic FEA was proposed for evaluating the creep-fatigue life in Mod.9Cr-1Mo steel weld joints. The creep-fatigue life obtained using the plate bending test was compared to those estimated from the results of inelastic FEA and by a simplified evaluation method.

  19. Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel Part II: Plate bending test and proposal of a simplified evaluation method

    International Nuclear Information System (INIS)

    Ando, Masanori; Takaya, Shigeru

    2016-01-01

    Highlights: • Creep-fatigue evaluation method for weld joint of Mod.9Cr-1Mo steel is proposed. • A simplified evaluation method is also proposed for the codification. • Both proposed evaluation method was validated by the plate bending test. • For codification, the local stress and strain behavior was analyzed. - Abstract: In the present study, to develop an evaluation procedure and design rules for Mod.9Cr-1Mo steel weld joints, a method for evaluating the creep-fatigue life of Mod.9Cr-1Mo steel weld joints was proposed based on finite element analysis (FEA) and a series of cyclic plate bending tests of longitudinal and horizontal seamed plates. The strain concentration and redistribution behaviors were evaluated and the failure cycles were estimated using FEA by considering the test conditions and metallurgical discontinuities in the weld joints. Inelastic FEA models consisting of the base metal, heat-affected zone and weld metal were employed to estimate the elastic follow-up behavior caused by the metallurgical discontinuities. The elastic follow-up factors determined by comparing the elastic and inelastic FEA results were determined to be less than 1.5. Based on the estimated elastic follow-up factors obtained via inelastic FEA, a simplified technique using elastic FEA was proposed for evaluating the creep-fatigue life in Mod.9Cr-1Mo steel weld joints. The creep-fatigue life obtained using the plate bending test was compared to those estimated from the results of inelastic FEA and by a simplified evaluation method.

  20. Application of TACT registered to the evaluation of total joint arthroplasty

    International Nuclear Information System (INIS)

    Fahey, Frederic H.; Webber, Richard L.; Chew, Felix S.-K.; Dickerson, Bryon A.

    2003-01-01

    Three-dimensional imaging may be valuable in the evaluation of total joint arthroplasty. The partial-volume effect and streak artifacts from the metallic components of these devices limit the applicability of computed tomography (CT) to this application. Tuned-aperture computed tomography registered (TACT registered ) is a tomographic approach that has been successfully used in other medical applications. In TACT, the acquisition geometry is inferred from the localization of fiducial markers in a series of projection images. The flexibility and robustness of TACT, as well as the fact that through an appropriate choice of reconstruction algorithms it can suppress streak artifacts, potentially makes it an appropriate approach for evaluating total joint arthroplasty. A simple computer-simulated model of a total knee replacement (TKR) was generated and used to evaluate the accuracy and artifacts associated with three-dimensional (3-D) renderings produced using TACT. A knee specimen from a cadaver that had received a TKR was used to investigate further the potential of TACT for this application. In both tests, TACT provided high-quality 3-D representations of the object. Both simple back-projection and minimum pixel back-projection were used to reconstruct the data. Minimum pixel back-projection provided high-contrast images that appeared to be relatively free of tomosynthetic artifacts. In summary, the potential of TACT in the evaluation of total joint arthroplasty was demonstrated. Future investigations will study TACT's ability to quantify the spatial relationship between the metallic components of these devices as well as TACT's ability to identify bony changes of diagnostic consequence

  1. Implementation of the IHR Joint External Evaluation: Taiwan's Experiences.

    Science.gov (United States)

    Lo, Yi-Chun

    In February 2016, the World Health Organization developed the Joint External Evaluation (JEE) tool to independently assess country capacity to prevent, detect, and respond to public health threats as part of the International Health Regulations (IHR) (2005) monitoring and evaluation framework. In light of this, the Taiwan government actively engaged at least 19 government agencies or institutions and voluntarily implemented the JEE. An External Assessment Team consisting of 6 US subject matter experts conducted the external evaluation, including site visits, from June 21 to July 1, 2016. The results, published on October 18, 2016, are useful and will be translated into actions and change in the system. Based on Taiwan's experiences, early stakeholder engagement and an experts' pre-JEE pilot visit would contribute to a successful JEE process.

  2. Joint evaluated file qualification for thermal neutron reactors

    International Nuclear Information System (INIS)

    Tellier, H.; Van der Gucht, C.; Vanuxeem, J.

    1986-09-01

    The neutron and nuclear data which are needed by reactor physicists to perform core calculations are brought together in the evaluated files. The files are processed to provide multigroup cross sections. The accuracy of the core calculations depends on the initial data, which is sometimes not accurate enough. Therefore the reactor physicists carry out integral experiments. We show, in this paper, how the use of these integral experiments and the application of a tendency research method can improve the accuracy of the neutron data. This technique was applied to the validation of the joint evaluated file. For this purpose, 56 buckling measurements and 42 isotopic analysis of irradiated fuel were used. Small modifications of the initial data are proposed. The final values are compared with recent recommended values or microscopic data. 8 refs

  3. Joint evaluated file qualification for thermal neutron reactors

    International Nuclear Information System (INIS)

    Tellier, H.; van der Gucht, C.; Vanuxeem, J.

    1986-01-01

    The neutron and nuclear data which are needed by reactor physicists to perform core calculations are brought together in the evaluated files. The files are processes to provide multigroup cross sections. The accuracy of the core calculations depends on the initial data, which is sometimes not accurate enough. Therefore the reactor physicists carry out integral experiments. The authors show, in this paper, how the use of these integral experiments and the application of a tendency research method can improve the accuracy of the neutron data. This technique was applied to the validation of the Joint evaluated file. For this purpose, 56 buckling measurements and 42 isotopic analysis of irradiated fuel were used. Small modifications of the initial data are proposed. The final values are compared with recent recommended values or microscopic data

  4. Evaluation relationship between temporomandibular joint disorder and headache: A review literature

    OpenAIRE

    Farzaneh Aghahosseini; Nafiseh Sheykhbahaei

    2017-01-01

    Background and Aims: Headache is among the most common complaints in patients suffering from temporomandibular joint disorders (TMD). Thus, it seems that evaluation of patients with headache in terms of temporomandibular joint (TMJ) disorders is necessary. In people with TMD, parafunctional activities play an important etiologic role. Considering the high prevalence of bruxism and TMDs in patients with headache, assessment the accuracy and severity of this association can play a key role in d...

  5. The joint evaluated file: a new nuclear library for reactor calculations

    International Nuclear Information System (INIS)

    Rowlands, J.L.; Tubbs, N.

    1986-01-01

    The Joint Evaluated File Project (JEF) was set up in 1982 to decide on the selection of evaluations and to plan the benchmark testing and future evaluation programme. A library, called JEF-1, has now been assembled and tested and is available to scientists in NEA Data Bank Member countries. It uses the ENDF/B-V format. Neutron interaction data are provided for some 300 nuclides. The ENDF/B-V Standards file has been adopted. For the remaining nuclides the data have been selected from recent American, Japanese and European evaluations, with only limited re-evaluations. New evaluations have been adopted for thermal scattering, fission product yields and radioactive decay data. The results of the benchmark testing of JEF-1 are considered satisfactory. The programme of re-evaluation work to develop an improved library, JEF-2, is now in progress. This also involves more sophisticated benchmark testing, concentrating on data for the primary actinides and structural materials. (author)

  6. Analysis of Using Acoustic Microscopy to Evaluate Defects in Spot Welding Joints

    Directory of Open Access Journals (Sweden)

    Korzeniowski M.

    2016-06-01

    Full Text Available The article presents the possibilities of using acoustic microscopy to evaluate defects in resistance spot welding joints. For this purpose, the welded joints were made from two grades of aluminium plates EN AW5754 H24 and EN AW6005 T606, which were then subjected to non-destructive testing using acoustic microscopy and conventional destructive testing using traditional light microscopy techniques. Additionally, the study examined the influence of the typical contaminants found in industrial conditions on the quality of the joint.

  7. Relevance of adjacent joint imaging in the evaluation of ankle fractures.

    Science.gov (United States)

    Antoci, Valentin; Patel, Shaun P; Weaver, Michael J; Kwon, John Y

    2016-10-01

    Routinely obtaining adjacent joint radiographs when evaluating patients with ankle fractures may be of limited clinical utility and an unnecessary burden, particularly in the absence of clinical suspicion for concomitant injuries. One thousand, three hundred and seventy patients who sustained ankle fractures over a 5-year period presenting to two level 1 trauma centers were identified. Medical records were retrospectively reviewed for demographics, physical examination findings, and radiographic information. Analyses included descriptive statistics along with sensitivity and predictive value calculations for the presence of adjacent joint fracture. Adjacent joint imaging (n=1045 radiographs) of either the knee or foot was obtained in 873 patients (63.7%). Of those, 75/761 patients (9.9%) demonstrated additional fractures proximal to the ankle joint, most commonly of the proximal fibula. Twenty-two of 284 (7.7%) demonstrated additional fractures distal to the ankle joint, most commonly of the metatarsals. Tenderness to palpation demonstrated sensitivities of 0.92 and 0.77 and positive predictive values of 0.94 and 0.89 for the presence of proximal and distal fractures, respectively. Additionally, 19/22 (86.4%) of patients sustaining foot fractures had their injury detectable on initial ankle X-rays. Overall, only 5.5% (75/1370) of patients sustained fractures proximal to the ankle and only 0.2% (3/1370) of patients had additional foot fractures not evident on initial ankle X-rays. The addition of adjacent joint imaging for the evaluation of patients sustaining ankle fractures is low yield. As such, patient history, physical examination, and clinical suspicion should direct the need for additional X-rays. Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Retrospective Evaluation Of MRI Findings Of Knee Joint In 255 Patients

    Directory of Open Access Journals (Sweden)

    Ahmet Mete

    2003-03-01

    Full Text Available Retrospective evaluation of knee MRI obtained from 255 cases and to demonstrate most common knee joint pathologies in our region.In our study knee joints of 255 cases who admitted to different clinics of our hospital with various complains of knee between October 1996 and December 1998 were examined in wide spectrum with MRI. Via 1.0 Tesla MRI device and special knee coil in sagittal, coronal and axial plains MRI images were obtained. The number of male and female patients were 173 and 82 and their ages were ranged between 14 and 70, and the mean age was 3413.The most common knee pathologies were intra-articular fluid (%58.04, medial (%46,66 and lateral (%12.55 meniscal injuries, anterior cruciate ligament injury (%17.25 and osteoarthritis (%14.9. The other important lesions were degeneration of medial and lateral meniscus, Baker’s cyst, bursitis, posterior cruciate ligament injury , medial and lateral collateral ligament injuries, synovial hypertrophy, chondromalasia of patella, and contusion.In our images of knee the most common lesions were injuries of meniscus and ligament. Because of being noninvasive technique for knee joint pathologies, capacity of multiplanar imaging, high contrast resolution and chance of detailed anatomic evaluation MR imaging was found to be most appropriate imaging technique for knee joint pathologies.

  9. Development of fatigue resistance evaluation method for socket-weld-jointed pipes

    International Nuclear Information System (INIS)

    Noguchi, Shinji; Shibayama, Motoaki; Iwata, Masazumi; Matsuura, Masayuki

    2003-01-01

    Vent line, drain line and sampling line in nuclear power station have many socket welded-joints made of austenitic stainless steel. Their slenderness and stagnation yield some potential of vibration-induced cracking and stress corrosion cracking. For the joints under vibration, the authors firstly elucidated their welding-defect-related fatigue strength by using fracture mechanics. It could define the allowable sets of stress amplitude and defect size. Secondly, authors developed an ultra-sonic detecting apparatus by using a focus-type probe and its programmed crawl on socket part. The authors finally measured the stress amplitude and frequency by sticking strain gage on suspected joints, then evaluated the fatigue resistance of the joints. For more efficient procedure, the method of stress amplitude analysis through vibration measurement is being developed. (author)

  10. Evaluation of Radiographic Instability of the Trapeziometacarpal Joint in Women With Carpal Tunnel Syndrome.

    Science.gov (United States)

    Kim, Jeong Hwan; Gong, Hyun Sik; Kim, Youn Ho; Rhee, Seung Hwan; Kim, Jihyoung; Baek, Goo Hyun

    2015-07-01

    To determine whether median nerve dysfunction measured by electrophysiologic studies in carpal tunnel syndrome (CTS) is associated with thumb trapeziometacarpal (TMC) joint instability. We evaluated 71 women with CTS and 31 asymptomatic control women. Patients with generalized laxity or TMC joint osteoarthritis were excluded. We classified the electrophysiologic severity of CTS based on nerve conduction time and amplitude and assessed radiographic instability of the TMC joint based on TMC joint stress radiographs. We compared subluxation ratio between patients with CTS and controls and performed correlation analysis of the relationship between the electrophysiologic grade and subluxation ratio. Thirty-one patients were categorized into the mild CTS subgroup and 41 into the severe CTS subgroup. There was no significant difference in subluxation ratio between the control group and CTS patients or between the control group and CTS subgroup patients. Furthermore, there was no significant correlation between electrophysiologic grade and subluxation ratio. This study demonstrated that patients with CTS did not have greater radiographic TMC joint instability compared with controls, and suggests that TMC joint stability is not affected by impaired median nerve function. Further studies could investigate how to better evaluate proprioceptive function of TMC joint and whether other nerves have effects on TMC joint motor/proprioceptive function, to elucidate the relationship between neuromuscular control of the TMC joint, its stability, and its progression to osteoarthritis. Diagnostic II. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Road network safety evaluation using Bayesian hierarchical joint model.

    Science.gov (United States)

    Wang, Jie; Huang, Helai

    2016-05-01

    Safety and efficiency are commonly regarded as two significant performance indicators of transportation systems. In practice, road network planning has focused on road capacity and transport efficiency whereas the safety level of a road network has received little attention in the planning stage. This study develops a Bayesian hierarchical joint model for road network safety evaluation to help planners take traffic safety into account when planning a road network. The proposed model establishes relationships between road network risk and micro-level variables related to road entities and traffic volume, as well as socioeconomic, trip generation and network density variables at macro level which are generally used for long term transportation plans. In addition, network spatial correlation between intersections and their connected road segments is also considered in the model. A road network is elaborately selected in order to compare the proposed hierarchical joint model with a previous joint model and a negative binomial model. According to the results of the model comparison, the hierarchical joint model outperforms the joint model and negative binomial model in terms of the goodness-of-fit and predictive performance, which indicates the reasonableness of considering the hierarchical data structure in crash prediction and analysis. Moreover, both random effects at the TAZ level and the spatial correlation between intersections and their adjacent segments are found to be significant, supporting the employment of the hierarchical joint model as an alternative in road-network-level safety modeling as well. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Evaluation of pavement joint sealants :a new testing technique

    OpenAIRE

    Abo-Qudais, Saad A.

    1992-01-01

    A new method to evaluate the performance of sealants, used in rigid pavement joints, was developed. A special fixture was designed to transfer cyclic in-line deflection, applied by a testing machine, to cyclic normal and shear deflections on a sealant sandwiched between two-2 x 2 x 2 in. portland cement mortar cubes. The normal and shear deflections were applied simultaneously at a specific ratio controlled by the developed fixture. The new testing method simulates field ...

  13. 77 FR 60746 - Proposed Information Collection (VA/DOD Joint Disability Evaluation Board Claim) Activity...

    Science.gov (United States)

    2012-10-04

    ... burden of the collection of information on respondents, including through the use of automated collection techniques or the use of other forms of information technology. Title: VA/DOD Joint Disability Evaluation... War on Terror Heroes, VA and the Department of Defense (DOD) have agreed to develop a joint process in...

  14. Developing a multi-joint upper limb exoskeleton robot for diagnosis, therapy, and outcome evaluation in neurorehabilitation.

    Science.gov (United States)

    Ren, Yupeng; Kang, Sang Hoon; Park, Hyung-Soon; Wu, Yi-Ning; Zhang, Li-Qun

    2013-05-01

    Arm impairments in patients post stroke involve the shoulder, elbow and wrist simultaneously. It is not very clear how patients develop spasticity and reduced range of motion (ROM) at the multiple joints and the abnormal couplings among the multiple joints and the multiple degrees-of-freedom (DOF) during passive movement. It is also not clear how they lose independent control of individual joints/DOFs and coordination among the joints/DOFs during voluntary movement. An upper limb exoskeleton robot, the IntelliArm, which can control the shoulder, elbow, and wrist, was developed, aiming to support clinicians and patients with the following integrated capabilities: 1) quantitative, objective, and comprehensive multi-joint neuromechanical pre-evaluation capabilities aiding multi-joint/DOF diagnosis for individual patients; 2) strenuous and safe passive stretching of hypertonic/deformed arm for loosening up muscles/joints based on the robot-aided diagnosis; 3) (assistive/resistive) active reaching training after passive stretching for regaining/improving motor control ability; and 4) quantitative, objective, and comprehensive neuromechanical outcome evaluation at the level of individual joints/DOFs, multiple joints, and whole arm. Feasibility of the integrated capabilities was demonstrated through experiments with stroke survivors and healthy subjects.

  15. Evaluation of serum cytokines in cats with and without degenerative joint disease and associated pain.

    Science.gov (United States)

    Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Aldrich, Lauren A; Vaden, Shelly; Lascelles, B Duncan X

    2017-01-01

    Degenerative joint disease is common in cats, with signs of pain frequently found on orthopedic examination and radiographs often showing evidence of disease. However, understanding of the pathophysiology of degenerative joint disease and associated pain remains limited. Several cytokines have been identified as having a role in pain in humans, but this has not been investigated in cats. The present study was performed to use a multiplex platform to evaluate the concentration of 19 cytokines and chemokines in serum samples obtained from cats with and without degenerative joint disease and associated pain. Samples from a total of 186 cats were analyzed, with cats representing a range of severity on radiographic and orthopedic evaluations and categorized by degenerative joint disease scores and pain scores. Results showed that cats with higher radiographic degenerative joint disease scores have higher serum concentrations of IL-4 and IL-8, while cats with higher orthopedic exam pain scores have higher concentrations of IL-8, IL-2, and TNF-α; increased concentration of IL-8 in degenerative joint disease and pain may be confounded by the association with age. Discriminant analysis was unable to identify one or more cytokines that distinguish between groups of cats classified based on degenerative joint disease score category or pain score category. Finally, cluster analysis driven by analyte concentrations shows separation of groups of cats, but features defining the groups remain unknown. Further studies are warranted to investigate any changes in cytokine concentrations in response to analgesic therapies, and further evaluate the elevations in cytokine concentrations found here, particularly focused on studies of local cytokines present in synovial fluid. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Investigations on evaluation method for yield strength of round bar undermatched joint

    International Nuclear Information System (INIS)

    Matsumoto, Toshimi; Satoh, Hiroshi; Wadayama, Yoshihide

    1988-01-01

    The objective values of the yield strength and fracture toughness are respectively more than 1200 MPa and 200 MPa √m at 4K on the structural material for the superconducting magnet container in the Fusion Reactor. It should be desirable to assure the above value for the properties of the weld metal used for the containers. The initial yielding behavior of the undermatched joint is investigated in this paper. Results are as follows. (1) On the nominal stress vs. nominal strain relationship at the central section of the undermatched metal of the joint, the stress increases higher than the yield stress of undermatched metal itself then gradually comes up to a constant value, after the whole area of the undermatched metal starts to generate plastic deformation as the stress reaches the yield stress of the metal. (2) The increase in the stress is caused by the restraint effect of the base metal on the plasticity, and the stress becomes larger with the larger strength ratio of the undermatched metal to the basemetal and with the smaller relative thickness of the joint. (3) The strain does not distribute uniformly at the central section of the undermatched metal along the radial direction during the initial yielding process of the joint. (4) In the case that the yield strength of the joints is considered as the proof stress desided for a constant offset strain, the relationship between the dimensionless yield strength of the joint to the yield stress of the base metal and the relative yield strength of the undermatched metal to the base metal cannot be not established consistently. (5) The assumption that the base metal is rigid, causes the excessive evaluation of the joint yield strength of theoretical analysis. (6) As the quantitative evaluation method, the stress vs. strain relationship and then the algebraic expression has been formulated for the initial yielding behavior of the joint. (author)

  17. Evaluation of mechanical strength of the joints in JT-60 toroidal field coil conductors

    International Nuclear Information System (INIS)

    Nishio, Satoshi; Ohkubo, Monoru; Sasajima, Hiroshi

    1980-04-01

    Toroidal field (TF) coils of JT-60 produce a toroidal field of 45 kG at a plasma axis, they have an inner bore of 3.90 m and a weight of about 80 metric tons per coil. Eighteen TF coils are located around a torus axis at regular intervals. TF coil conductors are mostly jointed by high frequency induction brazing, the rest jointed by welding. In deciding the details of the jointing procedures, the conductor size and the requested mechanical strength are mainly taken into consideration. Described are non-destructive inspection methods for the brazed joints, strength evaluation, and the inspection criteria. Ultrasonic testing method is found to be the most effective in evaluation of mechanical properties of the brazed joints especially in terms of fatigue strength. In section 1, specifications of the TF coils are given. In section 2, the ultrasonic inspection method and the detectability of this apparatus are described in detail, the defects of known size are compared with the indication values and display figures. The apparatus developed for JT-60 is operated automatically also recording the inspectionresults. In section 3, mechanical strength of the brazed joints with initial defects is discussed on the basis of Fracture Mechanics theory and results of the fatigue crack growth test. The inspection criteria in accordance with the descriptions of section 2 and 3 are given in section 4. (author)

  18. Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.

    Science.gov (United States)

    Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H

    2013-06-01

    One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.

  19. Ultrasonic evaluation of friction stud welded AA 6063/AISI 1030 steel joints

    International Nuclear Information System (INIS)

    Hynes, N. Rajesh Jesudoss; Nagaraj, P.; Sujana, J. Angela Jennifa

    2014-01-01

    Highlights: • Friction stud welding of AA 6063 and AISI 1030 was done successfully. • Ultrasonic evaluation of interfacial properties. • EDX analysis confirms intermetallic compound (FeAl) in the interfacial region. - Abstract: Friction stud welding is a promising technique in many applications related to oil and gas industries. It is used to attach grating to offshore oil platforms in areas where arc welding is not permitted because of the risk of causing a fire or explosion. Attachment of anodes inside seawater discharge pipelines in a gas processing plant is performed by this process. This solid state joining process permits metal combinations such as welding of aluminum studs to steel which would be problematic with arc welding because of the formation of thick and brittle inter-metallic compounds. In the present work, AA 6063 is joined to AISI 1030 steel using friction stud welding machine. Properties that are of interest to manufacturing applications such as Young’s modulus, longitudinal velocity, bulk modulus and shear modulus are evaluated by means of an ultrasonic flaw detector. At the interface of the joint, there is an increase of 4.4%, 1.8%, 1.15% and 4.42% is observed for the properties Young’s modulus, longitudinal velocity, bulk modulus and shear modulus respectively. This is due to the formation of intermetallic compound and increase in hardness at the interfacial region. Energy Dispersive X-ray analysis confirms the presence of FeAl as the intermetallic compound. Scanning Electron Microscope evaluation shows the presence of an unbound zone at the center of the inner region which is due to the minimum rotational speed and low axial load experienced at that point. In the unbound zone, there is an incomplete bond between dissimilar metals and it is detrimental to joint strength. Optimum value of friction time and usage of pure aluminum interlayer during the friction stud welding process hinders the formation of unbound zone and enhances the

  20. Evaluation of effects of different treatments for the wrist joints of subdominant hands using joint proprioception and writing time.

    Science.gov (United States)

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Hu, Yue; Rongming, Xia; Li, Zhou; Xiaojiao, Fu; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-05-01

    [Purpose] The purpose of this study was to examine immediate effects of strength training and NJF distal resistance training in wrist joints by using writing time and evaluation of proprioception using the JPE test. [Subjects and Methods] The subjects were 12 young healthy people (24.2 ± 3.1 y, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two isotonic contraction techniques were applied on the wrist joint: wrist joint extension muscle strength training (MST) and the wrist joint extension pattern of NJF. The uppercase English alphabet writing time and joint position errors of the left upper limb were measured before and after one intervention session of MST and NJF. [Results] The decrease in errors in wrist extension angle repetition and the writing time represented the improvement resulting from NJF. [Conclusion] This result suggests that the subdominant hands wrist joint proprioception and writing function can be improved by NJF together with proximal resistance training.

  1. Evaluation of the fusion technology and safety programme of the Joint Research Centre (1980-85)

    International Nuclear Information System (INIS)

    Haines, M.; Cabibbo, N.; Crocker, J.G.; Lecomte, M.; Merz, E.

    1986-01-01

    The Joint Research Centre, Ispra, has been involved in fusion research since 1973. In July 1985 the Commission of European Communities - DG XII, following a policy of systematically evaluating its RandD activities, appointed a panel of external experts to evaluate the fusion technology and safety programme carried out at the Joint Research Centre. This report describes the work of the panel in evaluating the research performed by the JRC within the framework of its 1984-87 programme. The achievements of the previous programme, 1980-83, were also taken into consideration. The different research areas covered in the programme, i.e.: reactor studies, breeding blanket technology, structural materials studies, risk assessment and tritium laboratory studies, are described and a draft proposal for the period 1987-90 presented. The evaluation panel has been asked to assess the following aspects: the scientific and technical achievements of the programme, the contribution of the programme to the development of other Community policies, the role played by the JRC in the European fusion research (including NET) and in international collaborations such as INTOR. From its assessment the evaluation panel has made a series of recommendations for the current programme and for future work

  2. Evaluation of stresses generated in steel finger joint of bridge by X-ray stress measurement

    International Nuclear Information System (INIS)

    Kohri, Ami; Kawano, Yutaka; Nishido, Takayuki

    2017-01-01

    In a steel bridge, the evaluation of the stress generated in the finger joint without a gap to absorb temperature change can be an index when evaluating the remaining life. This study chose as the object the finger joint of a diagonal bridge, where the generated stress state is considered to be more complicated, prepared a finger joint test specimen that simulated an actual part, and performed a load test. For judgment, FEM analysis, non-destructive X-ray stress measurement, and measurement of the generated stress using strain gauge were applied. Compared with the FEM analysis results, the difference in the stress value was generated due to the difference in the contact state, but the trends of the stress distribution were equivalent. In addition, the same measurement value as the strain gauge was obtained, and the validity of the X-ray stress measurement method was confirmed. As a result, it was found that the stress measurement method by X-ray is effective for measuring the generated stress including the residual stress of the finger joint without gap at a bridge. (A.O.)

  3. MR imaging evaluation of the temporomandibular joint following cervical extension-flexion injury (whiplash)

    International Nuclear Information System (INIS)

    Shellock, F.G.; Pressman, B.D.; Schames, J.; Schames, M.; Meeks, T.

    1990-01-01

    To determine abnormalities of the temporomandibular joint (TMJ) associated with cervical extension-flexion injury (whiplash) with use of MR imaging. Sixteen patients (32 joints) with TMJ syndrome-related symptoms after whiplash injuries from automobile accidents were evaluated by MR imaging. None of the patients had direct trauma to the jaw, mouth, or face. T1-weighted closed- and opened-mouth views were obtained in the sagittal plane, and closed-mouth views were obtained in the coronal plane. T2-weighted closed-mouth views obtained in the sagittal plane were also obtained to optimize identification of fluid/edema. Fourteen (87%) of 16 patients had one or more of the following TMJ abnormalities: 11 (34%) had anterior displacement of the disk with reduction and 2 (6%) had anterior displacement of the disk without reduction. On T2-weighted images, 17 TMJs (53%) had joint fluid and 5 (16%) had fluid localized to the capsule and/or pterygoid muscle. These data demonstrated a high incidence of TMJ abnormalities related to whiplash injury. The predominant finding was associated fluid/edema, suggesting that T2-weighted images are particularly useful for the evaluation of patients who present with whiplash injury

  4. Development and evaluation of a musculoskeletal model of the elbow joint complex

    Science.gov (United States)

    Gonzalez, Roger V.; Hutchins, E. L.; Barr, Ronald E.; Abraham, Lawrence D.

    1993-01-01

    This paper describes the development and evaluation of a musculoskeletal model that represents human elbow flexion-extension and forearm pronation-supination. The length, velocity, and moment arm for each of the eight musculotendon actuators were based on skeletal anatomy and position. Musculotendon parameters were determined for each actuator and verified by comparing analytical torque-angle curves with experimental joint torque data. The parameters and skeletal geometry were also utilized in the musculoskeletal model for the analysis of ballistic elbow joint complex movements. The key objective was to develop a computational model, guided by parameterized optimal control, to investigate the relationship among patterns of muscle excitation, individual muscle forces, and movement kinematics. The model was verified using experimental kinematic, torque, and electromyographic data from volunteer subjects performing ballistic elbow joint complex movements.

  5. Evaluation of body posture in individuals with internal temporomandibular joint derangement.

    Science.gov (United States)

    Munhoz, Wagner Cesar; Marques, Amélia Pasqual; de Siqueira, José Tadeu Tesseroli

    2005-10-01

    Temporomandibular dysfunctions (TMD) comprise a great number of disruptions that may affect the temporomandibular joint (TMJ), the masticatory muscles, or both. TMJ internal derangement is a specific type of TMD, of which the etiology and physiopathology are broadly unknown, but have been suggested to be linked to head, neck, and body posture factors. This study aimed at verifying possible relationships between body posture and TMJ internal derangements (TMJ-id), by comparing 30 subjects presenting typical TMJ-id signs to 20 healthy subjects. Subjects' clinical evaluations included anamnesis, stomatognatic system evaluation, and plotting analysis on body posture photographs. No statistically significant differences were found between the groups. Results do not support the assertion that body posture plays a role in causing or enhancing TMD; however, these results should be cautiously considered because of the small number of subjects evaluated and the many posture variables submitted to statistical procedures that lead to high standard deviations.

  6. An algorithm for the evaluation and treatment of sacroiliac joint dysfunction.

    Science.gov (United States)

    Carlson, Samuel W; Magee, Sean; Carlson, Walter O

    2014-11-01

    Approximately 90 percent of adults experience an episode of low back pain in their lifetime. Sacroiliac joint (SIJ) dysfunction has been shown to cause approximately 13-30 percent of LBP in the adult population. SIJ fusion is becoming an increasingly popular treatment alternative for SIJ dysfunction. This paper presents a literature-based algorithm to assist the clinician in the evaluation and treatment of patients with suspected SIJ dysfunction.

  7. Evaluation of risk factors for degenerative joint disease associated with hip dysplasia in dogs

    International Nuclear Information System (INIS)

    Smith, G.K.; Popovitch, C.A.; Gregor, T.P.; Shofer, F.S.

    1995-01-01

    Passive coxofemoral joint laxity of dogs, as quantitated by a distraction-stress radiographic method, may have important prognostic value in determining susceptibility to hip dysplasia. Data from 151 dogs, representing 13 breeds, were included in a logistic regression model to evaluate the contribution of factors such as age, breed, weight, sex, distraction index, and Norberg angle to the risk of developing degenerative joint disease (DJD) of the coxofemoral joint. Of the factors studied, the amount of passive hip laxity, as quantitated by the distraction index, was the most significant (P < 0.0001) determinant of the risk to develop DJD of the coxofemoral joint. In the longitudinal and cross-sectional components of the study, distraction index was a significant (P < 0.001) risk factor for DJD, irrespective of age at evaluation (4, 12, or 24 months). The strength of the hip laxity:DJD correlation increased with the age of dog. In contrast, the Norberg angle, a measure of hip laxity on the standard hip-extended radiograph, was not found to be a significant risk factor for DJD, either in the longitudinal or cross-sectional analyses. Breed-specific probability curves of DJD susceptibility indicated that German Shepherd Dogs had a significantly (P < 0.05) greater risk of developing DJD than did the pool of non-German Shepherd Dogs. The information derived from this statistical model will help to scientifically characterize the role of passive hip laxity as a component in the pathogenesis of DJD of the coxofemoral joint

  8. Technical guide to evaluate upper limb joints (shoulder, elbow and wrist) by ultrasound

    International Nuclear Information System (INIS)

    Obregon Baez, Luis Rafael

    2014-01-01

    A guideline to follow is offered to radiologists and residents of radiology service of medical imaging, when evaluating by ultrasound the shoulder joints, elbow, wrist. The importance to performing of musculoskeletal ultrasound by its pathology variable is established. The use of appropriate equipment and effective application of the techniques exposed of echography exploration have made enable the valuation of many pathologies with high sensitivity and specificity. The echography has been the musculoskeletal imaging technique that more rapidly has evolved. Currently, this technique has been replaced by magnetic resonance imaging in various clinical fields and also serves as a complement to other techniques. Exposed techniques have been of great benefit for radiologists medical and residents, obtaining with its use a quick guide for the realization of upper limb musculoskeletal ultrasounds. The appropriate and easy techniques are better known for the evaluation of these structures, and so document both sports injuries, as joint and rheumatic diseases [es

  9. Transcranial radiograph and magnetic resonance imaging in the evaluation of osseous changes of the temporomandibular joint

    International Nuclear Information System (INIS)

    Cho, Soo Beom; Koh, Kwang Joon

    2002-01-01

    To evaluate the diagnostic accuracy of transcranial radiographs and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) in the assessment of osseous changes of the condylar head and articular eminence. Osseous changes of the TMJ were evaluated in forty-three patients. Osseous changes of the condylar head and articular eminence were observed in 41 joints and 64 joints, respectively on transcranial radiographs, and 48 joints and 59 joints, respectively on MRI. The flattening, sclerosis, erosion, and osteophyte formation of the condylar heads were observed in 36.6%, 43.9%, 12.2%, and 7.3%, respectively on transcranial radiographs compared with 35.4%, 20.8%, 37.5%, and 6.3%, respectively on MRI. While, the flattening, sclerosis, and erosion of the articular eminences were observed in 26.6%, 67.2%, and 6.2%, respectively on transcranial radiographs compared with 32.2%, 59.3%, and 8.5%, respectively on MRI. There were no statistical differences between transcranial radiographs and MRI scans in the detection of osseous changes of the TMJ. However, MRI scans were superior to the transcranial radiographs in the detection of erosion of the condylar head (p<0.01).

  10. Transcranial radiograph and magnetic resonance imaging in the evaluation of osseous changes of the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Soo Beom; Koh, Kwang Joon [School of Dentistry, Chonbuk National University, Chonju (Korea, Republic of)

    2002-06-15

    To evaluate the diagnostic accuracy of transcranial radiographs and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) in the assessment of osseous changes of the condylar head and articular eminence. Osseous changes of the TMJ were evaluated in forty-three patients. Osseous changes of the condylar head and articular eminence were observed in 41 joints and 64 joints, respectively on transcranial radiographs, and 48 joints and 59 joints, respectively on MRI. The flattening, sclerosis, erosion, and osteophyte formation of the condylar heads were observed in 36.6%, 43.9%, 12.2%, and 7.3%, respectively on transcranial radiographs compared with 35.4%, 20.8%, 37.5%, and 6.3%, respectively on MRI. While, the flattening, sclerosis, and erosion of the articular eminences were observed in 26.6%, 67.2%, and 6.2%, respectively on transcranial radiographs compared with 32.2%, 59.3%, and 8.5%, respectively on MRI. There were no statistical differences between transcranial radiographs and MRI scans in the detection of osseous changes of the TMJ. However, MRI scans were superior to the transcranial radiographs in the detection of erosion of the condylar head (p<0.01).

  11. Musculoskeletal Model Development of the Elbow Joint with an Experimental Evaluation

    Directory of Open Access Journals (Sweden)

    Munsur Rahman

    2018-04-01

    Full Text Available A dynamic musculoskeletal model of the elbow joint in which muscle, ligament, and articular surface contact forces are predicted concurrently would be an ideal tool for patient-specific preoperative planning, computer-aided surgery, and rehabilitation. Existing musculoskeletal elbow joint models have limited clinical applicability because of idealizing the elbow as a mechanical hinge joint or ignoring important soft tissue (e.g., cartilage contributions. The purpose of this study was to develop a subject-specific anatomically correct musculoskeletal elbow joint model and evaluate it based on experimental kinematics and muscle electromyography measurements. The model included three-dimensional bone geometries, a joint constrained by multiple ligament bundles, deformable contacts, and the natural oblique wrapping of ligaments. The musculoskeletal model predicted the bone kinematics reasonably accurately in three different velocity conditions. The model predicted timing and number of muscle excitations, and the normalized muscle forces were also in agreement with the experiment. The model was able to predict important in vivo parameters that are not possible to measure experimentally, such as muscle and ligament forces, and cartilage contact pressure. In addition, the developed musculoskeletal model was computationally efficient for body-level dynamic simulation. The maximum computation time was less than 30 min for our 35 s simulation. As a predictive clinical tool, the potential medical applications for this model and modeling approach are significant.

  12. Evaluation of the high-temperature materials programme of the Joint Research Centre (1980-85)

    International Nuclear Information System (INIS)

    Glenny, R.J.E.; Boehm, H.; Gellings, P.J.; Gobin, P.; Lanzavecchia, G.; Nicholaides, C.

    1986-01-01

    This report covers the findings of the external panel of experts set up to evaluate the results of the Community's programme in the field of high-temperature materials (1980-85), carried out at the Petten establishment of the Joint Research Centre. The evaluation covers the quality and relevance of the research, the usefulness of the results and the role played by the JRC in this field at the European level. The report describes and gives comments on the content, structure and management of the five projects constituting the current programme, outlines the methods and procedures used during the evaluation and gives a number of recommendations pertinent to future activities

  13. The use of tibial tuberosity-trochlear groove indices based on joint size in lower limb evaluation.

    Science.gov (United States)

    Ferlic, Peter Wilhelm; Runer, Armin; Dirisamer, Florian; Balcarek, Peter; Giesinger, Johannes; Biedermann, Rainer; Liebensteiner, Michael Christian

    2018-05-01

    The correlation between tibial tuberosity-trochlear groove distance (TT-TG) and joint size, taking into account several different parameters of knee joint size as well as lower limb dimensions, is evaluated in order to assess whether TT-TG indices should be used in instead of absolute TT-TG values. This study comprised a retrospective analysis of knee CT scans, including 36 cases with patellofemoral instability (PFI) and 30 controls. Besides TT-TG, five measures of knee joint size were evaluated in axial CT slices: medio-lateral femur width, antero-posterior lateral condylar height, medio-lateral width of the tibia, width of the patella and the proximal-distal joint size (TT-TE). Furthermore, the length of the femur, the tibia and the total leg length were measured in the CT scanogram. Correlation analysis of TT-TG and the other parameters was done by calculating the Spearman correlation coefficient. In the PFI group lateral condylar height (r = 0.370), tibia width (r = 0.406) and patella width (r = 0.366) showed significant moderate correlations (p joint size or between TT-TG and measures of lower limb length. Tibial tuberosity-trochlear groove distance correlates with several parameters of knee joint size and leg length in patients with patellofemoral instability. Application of indices determining TT-TG as a ratio of joint size could be helpful in establishing the indication for medial transfer of the tibial tuberosity in patients with PFI. Level III.

  14. Fatigue strength evaluation of friction stir welded aluminium joints using the nominal and notch stress concepts

    International Nuclear Information System (INIS)

    Barsoum, Z.; Khurshid, M.; Barsoum, I.

    2012-01-01

    Highlights: ► Fatigue testing and evaluation of friction stir welded butt and overlap joints. ► Evaluation based on nominal and effective notch stress concept. ► Comparison with different design recommendations and codes. ► Higher fatigue strength and SN-slopes is observed. ► New fatigue design recommendations proposed for FSW joints. -- Abstract: In this study the fatigue strength is investigated for Friction Stir Welded (FSW) overlap and butt welded joints in different thicknesses based on nominal and effective notch stress concepts. The fatigue test results are compared with fatigue strength recommendations according to EN 1999-1-3 and International Institute of Welding (IIW). The results are also compared with available published data and Finite Element Analysis (FEA) is carried out to investigate the effect of plate thickness and nugget size on the fatigue strength of overlap joints. 3–3 mm butt welded joints shows the highest fatigue strength in comparison with 3–5 mm butt welded and overlap joints. Slopes of the SN-curves for two different joint types differ from the slope recommended by IIW. A specific failure trend is observed in overlap FSW joints. However, the slopes of the SN-curves are in close agreement with slopes found in EN 1999-1-3. The slopes of various published results and test results presented in this study are in good agreement with each other. The suggested fatigue design curves for the nominal and effective notch stress concept have a higher slope than given for fusion welds by IIW.

  15. Success factors for international HTA projects: evaluating EUnetHTA Joint Action as an exemplar.

    Science.gov (United States)

    Guegan, Eleanor Woodford; Cook, Andrew

    2014-11-01

    Evaluation is essential for the management of international projects or networks in health technology assessment (HTA). It extends beyond the normal process of project management by incorporating qualitative dimensions and provides information about a project's effectiveness and achievements. This article aimed to identify the factors that are important for the success of international HTA projects. The European network for Health Technology Assessment Joint Action (EUnetHTA JA) is presented as an exemplar. METHODS for the evaluation of international HTA projects include interviews, focus groups, questionnaires, observations and documentary review, and the key points of these approaches have been summarized. The impact and effectiveness of the EUnetHTA JA was evaluated by questionnaires of project participants and external stakeholders, and by documentary review. The response rate for the three annual questionnaires sent to project participants ranged from 86 percent to 88 percent and for external stakeholders ranged from 65 percent to 88 percent. Key factors for project success included production of deliverables according to the workplan, achievement of objectives, added value generated, effective communication, involvement of external stakeholders, workstream management and progress from the preceding EUnetHTA 2006-2008 project. The experience of this project can inform the evaluation of future international HTA collaborations, such as the EUnetHTA 2nd Joint Action and HTAsiaLink. A high response rate was achieved to the self-completion questionnaires and the strategy followed is recommended for evaluation of international HTA projects. Future assessments of international HTA projects should strive to measure outcomes and impact, not just outputs and process.

  16. Radiosynoviorthesis of acromioclavicular joint using 169Er-citrate: prospective evaluation of efficacy.

    Science.gov (United States)

    Vereb, Marika; Liepe, Knut; Fischer, Manfred; Kaliska, Lucia; Noskovicova, Lucia; Balogova, Sona

    2018-01-01

    There is a clinical need for therapeutic alternative in patients with persisting painful arthritis of AC-joint and failure of previous treatments. However, no radiopharmaceutical is currently explicitly approved for radiosynoviorthesis of acromioclavicular joint. The aim of our study was to prospectively assess the efficacy and safety of radiosynoviorthesis of acromioclavicular joint using erbium-169 citrate. Radiosynoviorthesis of acromioclavicular joint was performed in 51 consecutive patients (18 males, 33 females) mean age 64.3 (range 43.8-82.6, median 63.6) years with clinically confirmed arthritis of 85 acromioclavicular joints. The efficacy of RSO was reported by patients according to 10-step visual analogue scale of pain (VAS) (0 = no pain, 10 = most severe pain) at 6 months after radiosynoviorthesis and by ranking the global therapeutic effect of RSO in 4 categories (1 = the best effect, 4 = no change). To assess the variation of blood perfusion in treated joints, the efficacy of RSO was also evaluated by variation of target (acromioclavicular joint)/non-target (soft tissue) uptake ratio (T/NTR) of metylendiphosphonate (99mTc) measured as number of counts over region of interest on blood pool phase of two-phase bone scintigraphy performed before and 6 months after RSO. Radiosynoviorthesis was followed by significant decrease in VAS, mean - 3.1 (-47%). Excellent, good, moderate and bad response was observed in 57 (67%), 25 (29%), 1 (1%) and in 2 (2%) of acromioclavicular joints respectively. A significant correlation between decrease of T/NTR and variation of VAS in % (ρ = 0.532, p acromioclavicular joint in whom previous line(s) of treatment did not lead to satisfactory pain relief.

  17. Genetic conditions of joint Nordic genetic evaluations of lifetime competition performance in warmblood sport horses.

    Science.gov (United States)

    Viklund, Å; Furre, S; Eriksson, S; Vangen, O; Philipsson, J

    2015-08-01

    Breeding programmes for warmblood sport horses are similar in the Nordic countries Sweden, Denmark, Finland and Norway, and stallions of same origin are used. The aim was to investigate whether a joint Nordic genetic evaluation based on lifetime competition performance is feasible and beneficial for breeding competitive sport horses in the Nordic countries. Results for almost 45,000 horses in show jumping and 30,000 horses in dressage were available. The larger populations in Sweden and Denmark contributed with 85% of the results. Heritabilities and genetic correlations between performances in the different countries were estimated, and comparisons of accuracies of estimated breeding values (EBVs) and number of stallions with EBVs based on national or joint data were studied. The heritabilities ranged between 0.25 and 0.42 for show jumping and between 0.14 and 0.55 for dressage. The genetic correlations between competition performances in the Nordic countries were estimated to 0.63-1.00. EBVs based on joint data increased accuracies for EBVs for stallions by 38-81% and increased the number of available stallions with EBVs by 40-288%, compared to EBVs based on national data only. A joint Nordic genetic evaluation for sport horses is recommended. © 2015 Blackwell Verlag GmbH.

  18. Angular stable plates in proximal meta-epiphyseal tibial fractures: study of joint restoration and clinical and functional evaluation.

    Science.gov (United States)

    Giannotti, S; Giovannelli, D; Dell'Osso, G; Bottai, V; Bugelli, G; Celli, F; Citarelli, C; Guido, G

    2016-04-01

    The tibial plateau fractures involve one of the main weight bearing joints of the human body. The goals of surgical treatment are anatomical reduction, articular surface reconstruction and high primary stability. The aim of this study was to evaluate the clinical and functional outcomes after internal plate fixation of this kind of fractures. From January 2009 to December 2012, we treated 75 cases of tibial plateau fracture with angular stable plates. We used Rasmussen Score and the Knee Society Score for the clinical and functional evaluation. Twenty-five cases that underwent hardware removal had arthroscopic and CT evaluation of the joint. No complications occurred. The clinical and functional evaluation, performed by the KSS and Rasmussen Score, highlighted the high percentage of good-to-excellent results (over 90 %). In every case, the range of motion was good with flexion >90°. Arthroscopy showed the presence of chondral damage in 100 % of patients. In all the cases, we found that X-ray images seem better than the CT images. Angular stable plates allow to obtain a good primary stability, permitting an early joint recovery with an excellent range of motion. Avoiding to perform a knee arthrotomy at the time of fracture reduction could prove to be an advantage in terms of functional recovery. The meniscus on the injured bone should be preserved in order to maintain good function of the joint. X-ray images remain the gold standard in checking the progression of post-traumatic osteoarthritis.

  19. An Evaluation of Automotive Interior Packages Based on Human Ocular and Joint Motor Properties

    Science.gov (United States)

    Tanaka, Yoshiyuki; Rakumatsu, Takeshi; Horiue, Masayoshi; Miyazaki, Tooru; Nishikawa, Kazuo; Nouzawa, Takahide; Tsuji, Toshio

    This paper proposes a new evaluation method of an automotive interior package based on human oculomotor and joint-motor properties. Assuming the long-term driving situation in the express high way, the three evaluation indices were designed on i) the ratio of head motion at gazing the driving items; ii) the load torque for maintaining the standard driving posture; and iii) the human force manipulability at the end-point of human extremities. Experiments were carried out for two different interior packages with four subjects who have the special knowledge on the automobile development. Evaluation results demonstrate that the proposed method can quantitatively analyze the driving interior in good agreement with the generally accepted subjective opinion in the automobile industry.

  20. Dynamic evaluation method of lower limbs joint alignment (MADAAMI for dancers during the plié

    Directory of Open Access Journals (Sweden)

    Kaanda Nabilla Souza Gontijo

    Full Text Available Abstract In classical ballet, the joint misalignments during the plié can generate various injuries. To evaluate potential misalignments during the plié the aim of this study was to present a method for dynamic evaluation of lower limb alignment articulation (called MADAAMI. MADAAMI was validated by 12 experts, and for the evaluation of its reproducibility and for agreement with 3D kinematics, 20 dancers were assessed using a video recording of their plié. For statistical analysis we used the Kappa coefficient (k (p 0.40 and C > 80%, and it is a suitable and valid method for use by the same examiner.

  1. Reliability of a Functional Test Battery Evaluating Functionality, Proprioception and Strength of the Ankle Joint

    OpenAIRE

    YILDIZ, Yavuz; ŞEKİR, Ufuk; HAZNECİ, Bülent

    2009-01-01

    Aim: In contrast to the one-sided evaluation methods used in the past, combining multiple tests allows one to obtain a global assessment of the ankle joint. Materials and Methods: Twenty healthy male volunteers participated in this study. One component of the test battery included five different functional ability tests, which included: single limb hopping course, one-legged and triple-legged hop for distance, and six-meter (6-m) and cross 6-m hop for time. Ankle joint position sense and on...

  2. Radiographic evaluation of cervical spine of subjects with temporomandibular joint internal disorder.

    Science.gov (United States)

    Munhoz, Wagner Cesar; Marques, Amélia Pasqual; Siqueira, José Tadeu Tesseroli de

    2004-01-01

    Although the etiopathophysiology of internal temporomandibular joint internal disorders (TMJ ID) is still unknown, it has been suggested that head and body posture could be related to its initial onset, development and perpetuation. The purpose of the present study was to observe the relationship between cervical spine X-ray abnormalities and TMJ ID. This investigation evaluated 30 subjects with internal TMJ disorder symptoms (test group) and 20 healthy subjects (control group). Subjects were submitted to clinical and radiographic evaluation. Clinical evaluation comprised anamnesis and stomatognathic system physical examination. Radiographic evaluation comprised analysis of lateral cervical spine X-rays by three physical therapists and tracing on the same images. The test group presented twice as much cervical spine hyperlordosis as the control group (20.7% versus 10.5%), but almost half of rectification prevalence (41.4 versus 79.0%, p = 0.03). After that, the test group was divided into three subgroups according to TMJ dysfunction severity, evaluated by Helkimo's index. These subgroups were not significantly different, but the subgroup with more severe TMD showed a tendency to cervical spine hyperlordosis prevalence. Results showed a tendency for subjects with more severe TMD to exhibit cervical spine hyperlordosis. Nevertheless, studies with a larger number of subjects suffering from severe TMD are encouraged in order to corroborate the present findings.

  3. Exploring the relationship between costs and quality. Does the joint evaluation of costs and quality alter the rankings of Danish hospital departments?

    DEFF Research Database (Denmark)

    Hvenegaard, Anne; Nielsen Arendt, Jacob; Street, Andrew

    2011-01-01

    vascular departments, we estimate fixed effect models for costs (linear) and quality (logistic). We consider two quality measures; mortality and wound complications. To assess whether the joint evaluation of costs and quality affects the ranking of departments, we construct joint confidence regions......OBJECTIVE: The purpose is to evaluate the relationship between costs and quality and to assess whether the joint evaluation of costs and quality affects the ranking of hospital departments relative to comparison based on costs alone. METHODS: Using patient level data for 3,754 patients in six...... for each pair of departmental effects for costs and quality using a bootstrap method and rank departments according to their cost-effectiveness ratio. The findings are used to evaluate a theory of a U-shaped cost/quality relationship. RESULTS: The association between cost and quality differs depending...

  4. A Real-time Evaluation Technique of Fatigue Damage in Adhesively Bonded Composite-Metal Joints

    International Nuclear Information System (INIS)

    Kwon, Oh Yang; Kim, Tae Hyun

    1999-01-01

    One of the problems for practical use of fiber-reinforced plastics is the performance degradation by fatigue damage in the joints. The study is to develop a nondestructive technique for real-time evaluation of adhesively bonded composite-metal joints. From the prior study we confirmed that the bonding strength can be estimated from the correlation between the qualify of bonded parts and AUP's. We obtained a curve showing the correlation between the degree of fatigue damage and AUP's calculated from signals acquired during fatigue loading of single-lap and double-lap joints of CFRP and Al6061. The curve is an analogy to the one showing stiffness reduction (E/Eo) of polymer matrix composites by fatigue damage. From those facts, it is plausible to predict the degree of fatigue damage in real-time. Amplitude and AUP2 appeared to be optimal parameters to provide more reliable results for single-lap joints whereas Amplitude and AUP2 did for double-lap joints. It is recommended to select optimal parameters for different geometries in the application for real structures

  5. A real time evaluation technique of fatigue damage in adhesively bonded composite metal joints

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyun; Kwon Oh Yang [Dept. of Mechanical Engineering, Inje Univesity, Kimhae (Korea, Republic of)

    1999-05-15

    One of the problems for practical use of fiber-reinforced composite material is performance degradation by fatigue damage in the joints. The study is to develope a nondestructive technique for real-time evaluation of adhesively bonded composite-metal joints. From the prior study we confirmed that the bonding strength can be estimated from the correlation between quality of bonded parts and AUP's. We obtained a curve showing the correlation between AUP's calculated from signals obtained from single-lap and double-lap joints and the degree of fatigue damage at bonding interface during fatigue test. The curve is an analogy to the one showing stiffness reduction(E/E{sub 0}) of polymer matrix composites by fatigue damage. From those facts, it is possible to predict degree of damage in real-time. Amplitude and AUP2 appeared to be optimal parameters to provide more reliable results for single-lap joint whereas amplitude and AUP1 did for double-lap joints. It is recommended to select optimal parameters for different geometries in the real structure.

  6. A Real-time Evaluation Technique of Fatigue Damage in Adhesively Bonded Composite-Metal Joints

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Oh Yang; Kim, Tae Hyun [Inha University, Incheon (Korea, Republic of)

    1999-12-15

    One of the problems for practical use of fiber-reinforced plastics is the performance degradation by fatigue damage in the joints. The study is to develop a nondestructive technique for real-time evaluation of adhesively bonded composite-metal joints. From the prior study we confirmed that the bonding strength can be estimated from the correlation between the qualify of bonded parts and AUP's. We obtained a curve showing the correlation between the degree of fatigue damage and AUP's calculated from signals acquired during fatigue loading of single-lap and double-lap joints of CFRP and Al6061. The curve is an analogy to the one showing stiffness reduction (E/Eo) of polymer matrix composites by fatigue damage. From those facts, it is plausible to predict the degree of fatigue damage in real-time. Amplitude and AUP2 appeared to be optimal parameters to provide more reliable results for single-lap joints whereas Amplitude and AUP2 did for double-lap joints. It is recommended to select optimal parameters for different geometries in the application for real structures

  7. A real time evaluation technique of fatigue damage in adhesively bonded composite metal joints

    International Nuclear Information System (INIS)

    Kim, Tae Hyun; Kwon Oh Yang

    1999-01-01

    One of the problems for practical use of fiber-reinforced composite material is performance degradation by fatigue damage in the joints. The study is to develope a nondestructive technique for real-time evaluation of adhesively bonded composite-metal joints. From the prior study we confirmed that the bonding strength can be estimated from the correlation between quality of bonded parts and AUP's. We obtained a curve showing the correlation between AUP's calculated from signals obtained from single-lap and double-lap joints and the degree of fatigue damage at bonding interface during fatigue test. The curve is an analogy to the one showing stiffness reduction(E/E 0 ) of polymer matrix composites by fatigue damage. From those facts, it is possible to predict degree of damage in real-time. Amplitude and AUP2 appeared to be optimal parameters to provide more reliable results for single-lap joint whereas amplitude and AUP1 did for double-lap joints. It is recommended to select optimal parameters for different geometries in the real structure.

  8. Evaluation of fatigue cracks in FSW joints of industrial structural materials by laminography

    International Nuclear Information System (INIS)

    Sano, Yuji; Masaki, Kiyotaka; Kajiwara, Kentaro

    2016-01-01

    Friction stir welding (FSW) is an emerging technology for joining flat and thin metal materials and has been applied in manufacturing in aviation and automotive industries. Fatigue property is one of the most important items to be evaluated for the structural integrity of the products, and therefore, it is necessary to visualize the three-dimensional (3D) behavior of fatigue cracks propagating in the non-homogeneous and anisotropic stirred zone of FSW joints. We have applied laminography with synchrotron radiation of SPring-8 to the FSW joints of aluminum alloy as a typical structural material. The results showed that the fatigue cracks propagated in a unique way depending on the stirred material. (author)

  9. Colour Doppler ultrasonography evaluation of vascularization in the wrist and finger joints in rheumatoid arthritis patients and healthy subjects

    Energy Technology Data Exchange (ETDEWEB)

    Carotti, M. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Salaffi, F., E-mail: fsalaff@tin.it [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Morbiducci, J. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Ciapetti, A., E-mail: ciapetti.a@libero.it [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Bartolucci, L. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Gasparini, S. [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy); Ferraccioli, G. [Division of Rheumatology, Catholic University of the Sacred Heart, Rome (Italy); Giuseppetti, G.M. [Department of Radiology, Poliytechnic University of Marche, Ancona (Italy); Grassi, W. [Department of Rheumatology, Poliytechnic University of Marche, Ospedale A. Murri - Via dei Colli 52, 60035 Jesi, Ancona (Italy)

    2012-08-15

    Objectives: To evaluate the presence of blood flow by colour Doppler ultrasonography (CDUS) in the wrist and finger joints of rheumatoid arthritis (RA) patients and healthy subjects and to define a cut-off value of CDUS resistive index (RI). Methods: Forty-three patients with RA and 43 healthy controls were examined by CDUS. The wrists, second and third metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints were evaluated in each patient and healthy subject. Spectral Doppler analysis was performed in order to characterize the type of flow and a mean RI was measured to define a cut-off level. The area under receiver operating characteristic curve was used to evaluate the screening method's performance. Results: Flow was detected in 219 of the 430 total joints (50.9%) of RA patients (111 in the wrists, 49 in the MCP and 30 in the PIP joints). Healthy subjects had a quantifiable flow in 45 of the 430 joints (10.5%) and, in particular, 39 (86.4%) in the wrist, 5 (11.14%) in the MCP and 1 (2.2%) in the PIP joints. The intra- and inter-reader agreements for the detection of Doppler signal were very good (kappa 0.82 and 0.89, respectively). Mean RI values were 0.72 {+-} 0.06 in RA patients and 0.86 {+-} 0.06 in healthy subjects (p < 0.01). At cut-off point of RI < 0.79 the sensitivity was 89.6% and the specificity was 78.8% (positive likelihood ratio 4.22). Conclusion: DUS is a useful tool for the detection of abnormal blood flow in inflammatory joints of RA patients.

  10. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult case000.

  11. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon

    1988-01-01

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult cases.

  12. BUILDING MODEL ANALYSIS APPLICATIONS WITH THE JOINT UNIVERSAL PARAMETER IDENTIFICATION AND EVALUATION OF RELIABILITY (JUPITER) API

    Science.gov (United States)

    The open-source, public domain JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) API (Application Programming Interface) provides conventions and Fortran-90 modules to develop applications (computer programs) for analyzing process models. The input ...

  13. EVALUATING THE TARGET, EFFECT, ACTION INTERACTION (TEA MODEL OF SPINAL MANIPULATION THERAPY ON SACROILIAC JOINT DYSFUNCTION

    Directory of Open Access Journals (Sweden)

    Muhammad Salman Bashir

    2017-08-01

    Full Text Available Background: In physical therapy, usually the effects of treatment on any condition will be evaluated based on the mode of action on the target tissue. Some treatments will have direct and indirect effects. Due to indirect effects, there may be changes in other tissues or systems in and around the target tissue. The interaction between target, effect, and action was studied under TEA model. In sacroiliac joint dysfunction, Muscle Energy Technique (MET and Spinal Manipulation Therapy (SMT were proved as useful treatment approaches but one is targeted on muscles (MET the other targets on joint (SMT. The indirect effects of both the approaches can’t be neglected. This study focused on evaluating indirect effects of SMT. Methods: A pilot study was conducted to see the effect of Spinal Manipulation Therapy on muscles (Transverse Abdominus, Internal Oblique when applied in patients with sacroiliac joint dysfunction. 44 subjects diagnosed with sacroiliac joint dysfunction were recruited in the study. Resting thickness was measured by ultrasound before and after Spinal Manipulation Therapy. SPSS version 17 was used for statistical analysis. Paired t-test compared pre and post test results. Results: After conducting Pilot study revealed that Pre resting thickness of Transverse Abdominus and Internal Oblique is (3.5±0.10 and (5.47± 0.15 Post resting Thickness of TrA (Transverse Abdominus and Internal Oblique (IO is (3.90±0.12 and (7.63±0.80 Results are significant as P-Value 0.000 that is <0.05. Conclusion: Here is concluded that SMT is a useful method to treat muscles through its direct action is on the Sacroiliac joint in Sacroiliac joint dysfunction. So we can use it for treating muscles by applying on joints (Indirect method.

  14. Role of computed tomography in evaluation of osteochondritis dissecans of the elbow joint

    International Nuclear Information System (INIS)

    Park, Byung Lyul; Kim, Jeong Eun; Jee, Keum Nahn; Park, Yang Hee

    1995-01-01

    To evaluate the role of CT in early detection, location, and extent of osteochondritis dissecans (OCD) of the elbow joint. We reviewed surgically proved 27 cases of 22 patients with osteochondritis dissecans in elbow joint retrospectively. We compared simple x-ray (elbow AP and lateral) with CT on the basis of staging of OCD of talus by simple x-ray. The frequency of location was as follows: fourteen cases of capitellum, 5 cases of olecranon tip, 5 cases of medial epicondyle, 2 cases of trochlea, and 1 case of olecranon base. Among the 4 cases of normal finding on simple x-ray, CT showed 1 case each of stage I, II, III and IV OCD and among the 8 cases of stage I on simple x-ray, CT showed 2 cases of stage I, 1 case of stage II, and 5 cases of stage III. Among the 3 cases of stage II on simple x-ray, CT showed 1 case of stage II and 2 cases of stage III. Among the 5 cases of stage III on simple x-ray, CT showed 1 case of stage II, 2 cases of stage III, and 2 cases of stage IV, but it was difficult to detect the presence or absence of attachment between the articular cartilage of mother bone and osteochondral fragment CT was more accurate than simple x-ray in detection of loose body. CT might be an useful imaging modality in early diagnosis of OCD and evaluation of its anatomic location and extent in elbow joint

  15. 99m technetium-MDP bone scintigraphy in evaluation of painful joint prosthesis

    International Nuclear Information System (INIS)

    Milosevic, D.; Jaukovic, M.; Jaukovic, Lj.; Ajdinovic, B.

    2004-01-01

    In addition of clinical evaluation and x-ray radiography, the diagnosis of a loose joint prosthesis is often made by nuclear medicine imaging techniques. Differentiation between loosening and infected prosthesis is important for better treatment of those patients. Aim: The aim of this study was to reevaluate the scintigraphic patterns in patients with painful hip of knee arthroplasty. Material and Method: From 1996. to 2003. forty patients aged 49-78 years were referred for evaluation of possible loosening/infection joint prosthesis: 36 pts with 39 total/ partial hip prosthesis, 1 pt with knee prosthesis and 3 pts with history of previously extracted hip prosthesis due to infection. Whole body acquisition had been performed with a single head gamma camera three hours after the injection of 740 MBq 99m Tc-MDP. Scans were classified as: positive for loosening if abnormal uptake was shown at the tip of the prosthesis; positive for infection if diffuse abnormal uptake was shown around the implant; negative and indeterminate scans. Scintigraphic findings were compared to clinical follow up, histology or cultures. Results: Positive findings were found in 17 bone scans strongly suggesting loosening in 10 cases, infection of prosthesis in 4 cases and both loosening/infection in 3 cases. Bone scintigraphy was normal in 11pts. Scans of three pts with previously extracted hip prosthesis and scheduled for reimplatation, showed inhomogeneously and mildly increased uptake in femur. Most of scans classified as indeterminate (n=12) showed slightly increased tracer uptake in region of acetabular roof, greater or lesser tho chanter, suggesting bone remodeling due to the presence of implant, rather than loosening. Conclusion: 99m Tc-MDP bone scintigraphy had a significant role in assessing the painful joint prosthesis. Complementary diagnostic procedures should be considered in indeterminate scintiscans. (authors)

  16. The challenges of joint working: lessons from the Supporting People Health Pilot evaluation

    Directory of Open Access Journals (Sweden)

    Ailsa Cameron

    2007-10-01

    Full Text Available Purpose: This paper reports the findings of the evaluation of the Supporting People Health Pilots programme which was established to demonstrate the policy links between housing support services and health and social care services by encouraging the development of integrated services. The paper highlights the challenges of working across housing, health and social care boundaries. Method: The evaluation of the 6 health pilots rested on two main sources of data collection: Quarterly Project Evaluation Reports collected process data as well as reporting progress against aims and objectives. Semi-structured interviews - conducted across all key professional stakeholder groups and agencies and with people who used services - explored their experiences of these new services. Results: The ability of pilots to work across organisational boundaries to achieve their aims and objectives was associated not only with agencies sharing an understanding of the purpose of the joint venture, a history of joint working and clear and efficient governance arrangements but on two other characteristics: the extent and nature of statutory sector participation and, whether or not the service is defined by a history of voluntary sector involvement. In particular the pilots demonstrated how voluntary sector agencies appeared to be less constrained by organisational priorities and professional agenda and more able to respond flexibly to meet the complex needs of individuals. Conclusion and discussion: The pilots demonstrate that integrating services to support people with complex needs works best when the service is determined by the characteristics of those who use the service rather than pre-existing organisational structures.

  17. Results of total joint arthroplasty and joint preserving surgery in younger patients evaluated by alternative outcome measures.

    Science.gov (United States)

    Klit, Jakob

    2014-04-01

    Knee and hip OA is the clinical and pathological outcome of a functional and structural failure of the joint, resulting in pain and physical dysfunction. Despite the similarity in clinical presentation the pathogenesis seems to differ. Where knee OA is associated with obesity and trauma, hip OA is associated with FAI covering three fundamentally different hip deformities, including acetabular dysplasia; all hypothesized to initiates OA development. Where PAO is used worldwide as a joint-preserving procedure in acetabular dysplasia, TKA and THA are the treatment of choice of end stage OA. Traditional main outcomes are clinically objective surgeon-reported endpoints. Patient perceived outcomes are known to differ from these and PROMs are now recommended as the core set of outcomes. When evaluating the outcome in younger patients, this high demanding group can show ceiling-effects of the scores. The overall aim of this thesis was to investigate the consequences of PAO, TKA, and THA in younger patients evaluated by alternative outcomes in relation to satisfaction, fulfillment of expectations, symptoms of depression, the socioeconomic effects, and abilities in sex-life; to improve patient information prior to PAO, TKA and THA surgery. This PhD thesis is based on three studies. Study I is a cross-sectional survey of preserved hip joints with a mean follow-up of ten years after PAO. One hundred patients (121 PAO's) were eligible for inclusion. An inquiry to the National Patient registry identified 36 of PAO's (in 35 patients) being converted to THA. The 61 remaining patients (80 preserved hip joints) were asked to participate in this questionnaire based follow-up. Fifty-five patients (70 preserved hip-joints) accepted and constituted the study population. All patients received a questionnaire concerning aspects of functional ability, patient satisfaction, expectations, and quality of life following PAO. Both Study II and Study III are prospective multicenter cohort

  18. Research on elaboration of the evaluation guidelines for activities implemented jointly; Kyodo jisshi katsudo hyoka guide line sakutei chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Elaboration of the evaluation guidelines for activities implemented jointly (AIJ) was researched to prevent the earth from warming. AIJ is the means to globally promote countermeasures against global warming cost-effectively by optimally combining every country`s technology, know-how and fund. AIJ was established in the 1st Conference of the Parties (COPI) of the United Nations Framework Convention on Climate Change in March, 1995. The pilot phase of AIJ is first carried out by voluntary workers jointly with developing countries under the agreement of the parties. The current situation of activities is reported in COPI as materials for evaluation of AIJ. To promote AIJ, elaboration of the evaluation guidelines for AIJ Japan program is also necessary for Japan. This research arranged the contents of the evaluation guidelines and the method of classifying projects for AIJ Japan program, and carried out some case studies of promising projects to reduce greenhouse gas emission for future proposal. 3 figs., 31 tabs.

  19. Nondestructive evaluation of adhesive joints by C-scan ultrasonic testing

    International Nuclear Information System (INIS)

    Zeighami, Mehdi; Honarvar, Farhang

    2009-01-01

    Evaluation of the quality of adhesive bonding is an important issue in many industries who incorporate adhesive joints in their products. Over the past few decades, numerous acoustical techniques have been developed for nondestructive testing (NDT) of adhesively bonded joints. Among these techniques, the ultrasonic pulse-echo method is the most promising means for inspection of adhesive bonds. In practice, due to low impedance matching between adhesive and metal, the discrimination of a good bond from a bad bond is difficult. The low impedance matching also results in low contrast between perfect and disbanded zone in a C-scan image. In this paper, the quality of the interface between aluminum and epoxy is investigated by using an in-house built ultrasonic C-scan system. Two adhesion indices are proposed for producing C-scan images. To verify the capability of these indices, an adhesively bonded sample was fabricated using aluminum plates and epoxy. An artificial defect was implanted in the first interface of the specimens. The C-scan measurement prepared based on the proposed indices was able to reveal the defect much better than the C-scan image prepared by conventional approach. (author)

  20. Detection of early osteoarthritis in the centrodistal joints of Icelandic horses: Evaluation of radiography and low-field magnetic resonance imaging.

    Science.gov (United States)

    Ley, C J; Björnsdóttir, S; Ekman, S; Boyde, A; Hansson, K

    2016-01-01

    Validated noninvasive detection methods for early osteoarthritis (OA) are required for OA prevention and early intervention treatment strategies. To evaluate radiography and low-field magnetic resonance imaging (MRI) for the detection of early stage OA osteochondral lesions in equine centrodistal joints using microscopy as the reference standard. Prospective imaging of live horses and imaging and microscopy of cadaver tarsal joints. Centrodistal (distal intertarsal) joints of 38 Icelandic research horses aged 27-29 months were radiographed. Horses were subjected to euthanasia approximately 2 months later and cadaver joints examined with low-field MRI. Osteochondral joint specimens were classified as negative or positive for OA using light microscopy histology or scanning electron microscopy. Radiographs and MRIs were evaluated for osteochondral lesions and results compared with microscopy. Forty-two joints were classified OA positive with microscopy. Associations were detected between microscopic OA and the radiography lesion categories; mineralisation front defect (Pradiography and low-field MRI pooled lesion categories, but radiography was often superior when individual lesion categories were compared. Early stage centrodistal joint OA changes may be detected with radiography and low-field MRI. Detection of mineralisation front defects in radiographs may be a useful screening method for detection of early OA in centrodistal joints of young Icelandic horses. © 2015 EVJ Ltd.

  1. Nondestructive Evaluation of Friction Stir-Welded Aluminum Alloy to Coated Steel Sheet Lap Joint

    Science.gov (United States)

    Das, H.; Kumar, A.; Rajkumar, K. V.; Saravanan, T.; Jayakumar, T.; Pal, Tapan Kumar

    2015-11-01

    Dissimilar lap joints of aluminum sheet (AA 6061) of 2 mm thickness and zinc-coated steel sheet of 1 mm thickness were produced by friction stir welding with different combinations of rotational speed and travel speed. Ultrasonic C- and B-scanning, and radiography have been used in a complementary manner for detection of volumetric (cavity and flash) and planar (de bond) defects as the defects are in micron level. Advanced ultrasonic C-scanning did not provide any idea about the defects, whereas B-scanning cross-sectional image showed an exclusive overview of the micron-level defects. A digital x-ray radiography methodology is proposed for quality assessment of the dissimilar welds which provide three-fold increase in signal-to-noise ratio with improved defect detection sensitivity. The present study clearly shows that the weld tool rotational speed and travel speed have a decisive role on the quality of the joints obtained by the friction stir welding process. The suitability of the proposed NDE techniques to evaluate the joint integrity of dissimilar FSW joints is thus established.

  2. Comparison of Plain MRI and MR Arthrography in the Evaluation of Lateral Ligamentous Injury of the Ankle Joint

    Directory of Open Access Journals (Sweden)

    Mei-Chun Chou

    2006-01-01

    Conclusion: For evaluating ankle disability, using plain MRI alone is not adequate for correctly detecting lateral collateral ligamentous injury of the ankle joint. MR arthrography improves the sensitivity and the accuracy for ATaF and CF ligament injuries. It also helps in assessing coexisting pathologic lesions of ankle joints, especially impingement syndromes and osteochondral lesions, and provides more information for therapeutic decision making.

  3. POD evaluation for joint angles from inertial and optical motion capturing system

    International Nuclear Information System (INIS)

    Shimizu, Kai; Kobayashi, Futoshi; Nakamoto, Hiroyuki; Kojima, Fumio

    2016-01-01

    It has been recognized that advances in preventive maintenance can improve the sustainment of systems, facilities, and infrastructure. Robot technologies have also received attention for maintenance applications. In order to operate delicate tasks, multi-fingered robot hands have been proposed in cases where human capability is deficient. This paper deals with motion capturing systems for controlling the hand/arm robot remotely. Several types of motion capturing systems have been developed so far. However, it is difficult for individual motion capturing systems to measure precise joint angles of a human arm. Therefore, in this paper, we integrate the inertial motion capturing system with the optical motion capturing system to capture a human arm posture. By evaluating the reliability of each motion capturing system, the integration is carried out. The probability of detection (POD) is applied to evaluate and compare the reliability of datasets measured by each motion capturing system. POD is one of the widely used statistical techniques to determine reliability. We apply the â analysis to determine the POD(a) function from the data set. Based on the POD evaluation, two motion capturing systems are integrated. (author)

  4. Efficacy of double inversion recovery magnetic resonance imaging for the evaluation of the synovium in the femoro-patellar joint without contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Son, Ye Na; Jin, Wook; Jahng, Geon-Ho; Park, Yong Sung; Park, So Young [Kyung Hee University School of Medicine, Department of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of); Cha, Jang Gyu [Soonchunhyang University Bucheon Hospital, Department of Radiology, Bucheon-si, Gyeonggi-do (Korea, Republic of); Yun, Seong Jong [Kyung Hee University School of Medicine, Department of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of); Department of Radiology, Aerospace Medical Center, Republic of Korea Air Force, Cheongwon-gun, Chungcheongbuk-do (Korea, Republic of); Park, Ji Seon; Ryu, Kyung Nam [Kyung Hee University Hospital, Department of Radiology, Seoul (Korea, Republic of)

    2018-02-15

    To investigate the efficacy of double inversion recovery (DIR) sequence for evaluating the synovium of the femoro-patellar joint without contrast enhancement (CE). Two radiologists independently evaluated the axial DIR and CE T1-weighted fat-saturated (CET1FS) images of 33 knees for agreement; the visualisation and distribution of the synovium were evaluated using a four-point visual scaling system at each of the five levels of the femoro-patellar joint and the location of the thickest synovium. The maximal synovial thickness at each sequence was measured by consensus. The interobserver agreement was good (κ = 0.736) for the four-point scale, and was excellent for the location of the thickest synovium on DIR and CET1FS (κ = 0.955 and 0.954). The intersequential agreement for the area with the thickest synovium was also excellent (κ = 0.845 and κ = 0.828). The synovial thickness on each sequence showed excellent correlation (r = 0.872). The DIR showed as good a correlation as CET1FS for the evaluation of the synovium at the femoro-patellar joint. DIR may be a useful MR technique for evaluating the synovium without CE. (orig.)

  5. Evaluation of an intact, an ACL-deficient, and a reconstructed human knee joint finite element model.

    Science.gov (United States)

    Vairis, Achilles; Stefanoudakis, George; Petousis, Markos; Vidakis, Nectarios; Tsainis, Andreas-Marios; Kandyla, Betina

    2016-02-01

    The human knee joint has a three-dimensional geometry with multiple body articulations that produce complex mechanical responses under loads that occur in everyday life and sports activities. Understanding the complex mechanical interactions of these load-bearing structures is of use when the treatment of relevant diseases is evaluated and assisting devices are designed. The anterior cruciate ligament (ACL) in the knee is one of four main ligaments that connects the femur to the tibia and is often torn during sudden twisting motions, resulting in knee instability. The objective of this work is to study the mechanical behavior of the human knee joint and evaluate the differences in its response for three different states, i.e., intact, ACL-deficient, and surgically treated (reconstructed) knee. The finite element models corresponding to these states were developed. For the reconstructed model, a novel repair device was developed and patented by the author in previous work. Static load cases were applied, as have already been presented in a previous work, in order to compare the calculated results produced by the two models the ACL-deficient and the surgically reconstructed knee joint, under the exact same loading conditions. Displacements were calculated in different directions for the load cases studied and were found to be very close to those from previous modeling work and were in good agreement with experimental data presented in literature. The developed finite element model for both the intact and the ACL-deficient human knee joint is a reliable tool to study the kinematics of the human knee, as results of this study show. In addition, the reconstructed human knee joint model had kinematic behavior similar to the intact knee joint, showing that such reconstruction devices can restore human knee stability to an adequate extent.

  6. Evaluation of the marsh deer stifle joint by imaging studies and gross anatomy.

    Science.gov (United States)

    Shigue, D A; Rahal, S C; Schimming, B C; Santos, R R; Vulcano, L C; Linardi, J L; Teixeira, C R

    2015-12-01

    This study aimed to evaluate the stifle joint of marsh deer using imaging studies and in comparison with gross anatomy. Ten hindlimbs from 5 marsh deer (Blastocerus dichotomus) were used. Radiography, computed tomography (CT) and magnetic resonance imaging (MRI) were performed in each stifle joint. Two hindlimbs were dissected to describe stifle gross anatomy. The other limbs were sectioned in sagittal, dorsal or transverse planes. In the craniocaudal radiographic view, the lateral femoral condyle was broader than the medial femoral condyle. The femoral trochlea was asymmetrical. Subsequent multiplanar reconstruction revealed in the cranial view that the external surface of the patella was roughened, the medial trochlea ridge was larger than the lateral one, and the extensor fossa at the lateral condyle was next to the lateral ridge. The popliteal fossa was better visualized via the lateral view. Sagittal MRI images identified lateral and medial menisci, caudolateral and craniomedial bundles of cranial cruciate ligament, caudal cruciate ligament, patellar ligament and common extensor tendon. In conclusion, the marsh deer stifle presents some anatomical characteristics of the ovine stifle joint. © 2014 Blackwell Verlag GmbH.

  7. Evaluation of base material and welded joints designated for membrane wall components made from low-alloy steels in large boilermaker conditions

    Energy Technology Data Exchange (ETDEWEB)

    Dobrzanski, Janusz; Zielinski, Adam [Institute for Ferrous Metallurgy, Gliwice (Poland); Pasternak, Jerzy [Boiler Engineering Company RAFAKO S.A., Raciborz (Poland)

    2010-07-01

    Supercritical operating parameters of lower emission power units require novel creep resisting steels. Therefore, this paper constains selected information, results of collectors made from the new low-alloy bainitic creep-resistant steels as 7CrWVNb9-6(P23) and 7CrMoVTiB10-10(P24) performed in large boilermaker conditions. The research and implementation process includes: - evaluation, comparison of requested properties of base material and welded joints as tensile strength, impact strength and technological properties, - destructive examinations with evaluation of welded joints and HAZ structure and hardness distribution, - evaluation of creep resistance properties and structure stability after heat treatments and again process of base material, HAZ and welded joints, - influence of manufacturing process in large boilermaker conditions and after simulated operation. A new creep-resistant steels to be used, in order to comply with the operational requirements, as to assure the appropriate reliability and safety of the boiler equipment in operation process. (orig.)

  8. Facet joint injuries in acute cervical spine trauma : evaluation with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Jeon Ju; Kim, Dong Hyun; Lee, Jeong Hwa; Lee, Keon; Kwon, Hyeok Po; Kwon, Jung Hyeok; Yun, Seong Mun [Dongkang General Hospital, Seoul (Korea, Republic of)

    1999-05-01

    To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, transverse, or comminuted, but vertical fracture was the most common. Various degrees of dislocation were observed in patients with facet fractures. Fractures other than facet included pillar(n=11), lamina(n=6), transverse process(n=14), body(n=13), and spinous process(n=3). On MR images, anterior longitudinal ligament injury was found in 8 patients(30%), posterior longitudinal ligament injury in 4(15%), and interspinous ligament injury in 20(74%). Twelve patients(44%) had spinal cord injuries including edema(n=8) and hemorrhage(n=4). Among patients with disc abnormalities, 11(41%) had intervertebral disc injuries, and traumatic disc herniations were found in nine. Traumatic cervical facet joint injuries were manifested as various patterns and frequently associated with other fractures or soft tissue injuries. Analysis of CT and MR findings of these injury patterns helped formulate a therapeutic plan and determine of prognosis.

  9. Optimum conductive fabric sensor sites for evaluating the status of knee joint movements using bio-impedance

    Directory of Open Access Journals (Sweden)

    Kim Jinkwon

    2011-06-01

    Full Text Available Abstract Background There have been many studies that utilize the bio-impedance measurement method to analyze the movements of the upper and lower limbs. A fixed electrical current flows into the limbs through four standard disposable electrodes in this method. The current flows in the muscles and blood vessels, which have relatively low resistivity levels in the human body. This method is used to measure bio-impedance changes following volume changes of muscles and blood vessels around a knee joint. The result of the bio-impedance changes is used to evaluate the movements. However, the method using the standard disposable electrodes has a restriction related to its low bio-impedance changes: the standard disposable electrodes are only able to measure bio-impedance from a limited part of a muscle. Moreover, it is impossible to use continuously, as the electrodes are designed to be disposable. This paper describes a conductive fabric sensor (CFS using a bio-impedance measurement method and determines the optimum configuration of the sensor for estimating knee joint movements. Methods The upper side of subjects' lower limbs was divided into two areas and the lower side of subjects' lower limbs was divided into three areas. The spots were matched and 6 pairs were selected. Subjects were composed of 15 males (age: 30.7 ± 5.3, weight: 69.8 ± 4.2 kg, and height: 173.5 ± 2.8 cm with no known problems with their knee joints. Bio-impedance changes according to knee joint flexion/extension assessments were calculated and compared with bio-impedance changes by an ankle joint flexion/extension test (SNR I and a hip joint flexion/extension test (SNR II. Results The bio-impedance changes of the knee joint flexion/extension assessment were 35.4 ± 20.0 Ω on the (1, 5 pair. SNR I was 3.8 ± 8.4 and SNR II was 6.6 ± 7.9 on the (1, 5 pair. Conclusions The optimum conductive fabric sensor configuration for evaluating knee joint movements were represented by

  10. Quantitative evaluation of hip joint laxity in 22 Border Collies using computed tomography

    International Nuclear Information System (INIS)

    Kishimoto, M.; Yamada, K.; Pae, S.H.; Muroya, N.; Watarai, H.; Anzai, H.; Shimizu, J.; Iwasaki, T.; Miyake, Y.; Wisner, E.R.

    2009-01-01

    The purpose of this study was to obtain the computed tomography (CT) data for the hip joints of 22 Border Collies. The dorsolateral subluxation (DLS) score, lateral center edge angle (LCEA), dorsal acetabular rim angle (DARA) and center distance (CD) index were measured on the CT images in a weight-bearing position. Radiographic Norberg angle (NA) was also measured. The mean values were 45.7+-10.2% for DLS score, 85.9deg+-10.3deg for LCEA, 18.5deg+-7.3deg for DARA, 0.40+-0.17 for CD index and 102.7deg+-6.9deg for NA. Since the DLS score and LCEA showed strong correlation, combined use of these parameters might improve diagnostic accuracy. We consider CT evaluation in a weight-bearing position to be a useful method for multidirectional evaluation of hips

  11. Joint IAEA/FAO evaluation the Agency's activities in some sectors of agriculture in Sub-Saharan Africa. Based on field evaluation in Kenya, Senegal, United Republic of Tanzania and Zambia. Special evaluation review

    International Nuclear Information System (INIS)

    1996-11-01

    A desk review was completed in 1995 of the Agency's activities in the Sub-Saharan region during the previous ten years, covering soil science, irrigation and plant nutrition, plant breeding and genetics, and agricultural biochemistry. As a follow-up of the recommendations of this review, a field evaluation covering activities in Kenya, Senegal, Tanzania and Zambia, as four of the six participants in the first phase of the ongoing regional project ''Increasing Food Security in Sub-Saharan Africa'', was conducted in 1996 jointly with the FAO Programme and Budget Evaluation. Ethiopia and Niger were not included in the field evaluation. To date, total disbursement during the last ten years in the 19 projects considered in this evaluation amounted to $2.5 million, evenly distributed in the four countries, plus about $500,000 for training funded outside the projects. Agency inputs included isotope analysers, sample preparation equipment, moisture and density gauges, labelled fertilizers, isotopes and supporting soil laboratory equipment, training of researchers and technicians and expert advice on research trials and on-the-job training on the use of laboratory equipment. Figs, tabs

  12. Experimental and clinical evaluation of acromioclavicular joint structures with new scan orientations in MRI

    International Nuclear Information System (INIS)

    Schaefer, Fritz K.; Schaefer, Philipp J.; Brossmann, Joachim; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas

    2006-01-01

    The objective of the study was to evaluate MRI for visualization of acromioclavicular (ac) joint structures in cadaveric shoulders, asymptomatic volunteers and symptomatic patients with trauma of the ac-joint. Three cadaveric shoulders were examined to find adequate planes and sequences for MRI. Afterwards, MR images were correlated to corresponding anatomical sections. Six asymptomatic volunteers and 13 patients were scanned in a 1.5 T Magnetom Vision with three sequences in the following planes: (1) parallel to the clavicle; (2) orthogonal to the ac joint, each time a fat-suppressed proton density-weighted + T2-sequence (TR/TE 4,000/15 ms) was performed; (3) parallel to the clavicle, T1-SE (TR/TE 817/20 ms). The parameters were: slice thickness 3 mm, field-of-view 180 mm, matrix 210 x 256 pixels. Standard of reference in the patients was clinical examination and conventional X-rays. Classification was by Rockwood grades I-VI. MRI allowed excellent visualization and diagnoses of ac-joint structures in volunteers and patients (n=6 normal, n=1 Rockwood I, n=5 Rockwood II, n=3 Rockwood III, n=4 Rockwood V). On MRI, in one lesion type II and III each, a lower lesion type was suspected clinically and by X-ray. In one patient additional information by MRI led to surgery. MRI allows excellent anatomical display of ac-joint structures and can give clinically relevant information on type and extension of ac-joint trauma, which may influence therapy. (orig.)

  13. Experimental and clinical evaluation of acromioclavicular joint structures with new scan orientations in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Fritz K.; Schaefer, Philipp J.; Brossmann, Joachim; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas [University Hospital of Schleswig-Holstein Campus Kiel, Department of Diagnostic Radiology, Kiel (Germany)

    2006-07-15

    The objective of the study was to evaluate MRI for visualization of acromioclavicular (ac) joint structures in cadaveric shoulders, asymptomatic volunteers and symptomatic patients with trauma of the ac-joint. Three cadaveric shoulders were examined to find adequate planes and sequences for MRI. Afterwards, MR images were correlated to corresponding anatomical sections. Six asymptomatic volunteers and 13 patients were scanned in a 1.5 T Magnetom Vision with three sequences in the following planes: (1) parallel to the clavicle; (2) orthogonal to the ac joint, each time a fat-suppressed proton density-weighted + T2-sequence (TR/TE 4,000/15 ms) was performed; (3) parallel to the clavicle, T1-SE (TR/TE 817/20 ms). The parameters were: slice thickness 3 mm, field-of-view 180 mm, matrix 210 x 256 pixels. Standard of reference in the patients was clinical examination and conventional X-rays. Classification was by Rockwood grades I-VI. MRI allowed excellent visualization and diagnoses of ac-joint structures in volunteers and patients (n=6 normal, n=1 Rockwood I, n=5 Rockwood II, n=3 Rockwood III, n=4 Rockwood V). On MRI, in one lesion type II and III each, a lower lesion type was suspected clinically and by X-ray. In one patient additional information by MRI led to surgery. MRI allows excellent anatomical display of ac-joint structures and can give clinically relevant information on type and extension of ac-joint trauma, which may influence therapy. (orig.)

  14. Patients' perceptions of joint teleconsultations: a qualitative evaluation.

    Science.gov (United States)

    Harrison, Robert; Macfarlane, Anne; Murray, Elizabeth; Wallace, Paul

    2006-03-01

    To determine patient perceptions of joint teleconsultations (JTC), with particular reference to reasons underlying, and factors contributing to, patient satisfaction and dissatisfaction with this mode of health delivery. Telemedicine has been welcomed as one way of improving health-care delivery, by improving patient access to secondary care and specialist services hence widening patient choice, particularly for patients outside major conurbations. However, a recent systematic review found currently available data on patient satisfaction with telemedicine to be methodologically flawed. Qualitative evaluations offer the opportunity to elucidate the details of patient satisfaction with this mode of health-care delivery. Qualitative study using semi-structured interviews. Purposive sample of 28 participants of a major randomized controlled trial (Virtual Outreach study) of JTC conducted in one urban and one rural area in Britain. Joint teleconferenced consultations with the patient, patient's general practitioner (GP), and a hospital specialist. The patient and GP were sited in the local practice, while the hospital specialist was in the hospital outpatient department, and the two parties were connected by an ISDN2 link and video-conferencing software. Patient experiences of JTC, with particular reference to reasons underlying, and factors contributing to, overall satisfaction or dissatisfaction. Two major themes were identified: customer care and doctor-patient interaction. Patients appreciated the customer care aspects of JTC, particularly the enhanced convenience, reduced costs and improved punctuality associated with JTC. However, there were divergent views about the doctor-patient interactions with some patients expressing a sense of alienation arising from the use of technology, and problems with doctor-patient communication. These data add significantly to the existing literature on patient satisfaction with telemedicine, by elucidating the factors underlying

  15. Scintigraphic evaluation of the sacroiliac joints in anklylosing spondylitis

    International Nuclear Information System (INIS)

    Schoerner, W.

    1980-01-01

    The sedimentation of sup(99m)Tc-phosphate complexes into the sacroiliac joints was investigated in 94 patients with loin pains and suspected of ankylosing spondylitis (SpA) and a control group of 96 healthy patients. The investigation yields the following results: 1. the visual evaluation of the scintigrams does not allow a reliable diagnosis and should be replaced by a semi-quantitative technique, 2. the index ISC/sacrum does remarkably depend on age, 3rd even in young patients the scintigraphic examination appears to be useful to alidate the clinical suspicion of sacroilictis which is in contradiction to literature, 4th with increasing SpA the scintigraphic detectability of changes in the ISG decreases. 5th the floriditily of the ISG process determines the scintigraphic detectability of the process of the disease, 6th the scintigraphic finding is unspecific. Inflammatory states of the disease of different genesis and degenerative processes in the ISG equally yield pathological index values. (orig./MG) [de

  16. Evaluation and Learning Policy

    International Development Research Centre (IDRC) Digital Library (Canada)

    Amy Etherington

    decisions. More broadly, evaluation generates knowledge about research and development. ... toward common goals; evaluations are part of our commitment to document and assess our joint .... of both qualitative and quantitative measures.

  17. Evaluation of the relationship between age, gender, and body mass index, and lumbar facet joint pain

    Directory of Open Access Journals (Sweden)

    Arman Taheri

    2016-01-01

    Full Text Available Introduction: Lumbar facet joint pain accounts for 5-15% of the cases of chronic, axial low back pain. Most commonly, facetogenic pain is the result of repetitive stress and/or cumulative low level trauma, leading to inflammation and stretching of the joint capsule. Patients and Methods: In this descriptive study 76 patients who were diagnosed, after a diagnostic block, as having lumbar facet joint pain were evaluated by their age, sex, and body mass index (BMI. Data were collected according to a checklist and entered to SPSS version 16. Results: The mean age of the participants was 48.53 years; the participants included 44 women and 32 men. Lumbar facet joint pain was more frequent in the age range of 40-55 years. With respect to BMI, lumbar facet joint pain was most frequently seen in patients with BMI of 24.5-29.5 kg/m 2 (40.8%. Conclusion: Based on our findings, the chances of developing lumbar facet joint pain is more in women who are between 40 years and 55 years of age and whose BMI is 24.5-29.5 kg/m 2 .

  18. MRI EVALUATION OF PAINFUL KNEE JOINT- THE CORRELATION OF MULTIPLE COEXISTING PATHOLOGIES, AGE AND SEX

    Directory of Open Access Journals (Sweden)

    Mukheswar Pame

    2017-03-01

    Full Text Available BACKGROUND 1. To evaluate the incidence and coexistence of multiple knee joint pathologies causing painful knee and their correlation to age and sex. 2. To evaluate the Magnetic Resonance Imaging (MRI features in various knee pathologies and to identify the common lesions. MATERIALS AND METHODS A retrospective study was performed using the clinical data of patients presenting with painful knee joint which were evaluated with MRI. Data from 200 patients examined between September 2015 and August 2016 were included into this study. The data was analysed statistically to evaluate the correlation between the MR pathological findings to age and sex of the patients. RESULTS The patient’s age ranged between 8 and 75 years (mean: 36 years. Anterior cruciate ligament (ACL tear was the commonest finding (60% followed by bursitis (55%, meniscal degeneration (54.6% and meniscal tear (52%. Primary signs of ACL tear were hyperintensity, discontinuity and nonvisualisation. Secondary signs like Posterior cruciate ligament (PCL buckling, PCL index of greater than 0.5, uncovered Lateral meniscus (LM and bone contusion assisted in diagnosis in indeterminate cases. Mid substance was the commonest site of ACL tear (64%. PCL tear accounted for only a small percentage (7%. Medial Meniscus (MM tear (35% was commoner than LM tear (17%. The posterior horn of meniscus was the commonest site of injury (86.5%. Age was significantly correlated with meniscal degeneration and tear, Medial collateral ligament (MCL degeneration, parameniscal cyst, and chondromalacia patellae. A significant correlation between male gender and ACL injury was noted. Meniscal injury was significantly correlated with bursitis, as well with MCL injury. Bone bruise was significantly correlated with ACL injury, MCL injury and Lateral collateral ligament (LCL injury. CONCLUSIONS MRI findings of certain pathologies in a painful knee can coexist and significantly correlate with each other, age and sex of

  19. Evaluation of C-Reactive Protein Level in Patients with Pain Form of Temporomandibular Joint Dysfunction

    Directory of Open Access Journals (Sweden)

    Malgorzata Pihut

    2018-01-01

    Full Text Available Temporomandibular joint dysfunction is a functional disorder concerned with the abnormal functioning of the muscles of the stomatognathic system and temporomandibular joints involved in the dynamic movements of the jaw and surrounding structures. The aim of the study was to compare the level of C-reactive protein in patients with pain and painless forms of temporomandibular joint dysfunction. Materials and methods. The study group consisted of 72 patients who reported to the prosthetic treatment because of temporomandibular joint dysfunction. The study group included 36 patients with pain form of dysfunction, and the control group included 36 patients with painless form of disorder. Each patient underwent specialized examination of functional disorders in order to diagnose the type of dysfunction and was commissioned to carry out a study of the blood test concerned with evaluation of the C-reactive protein (CRP level in the same analytical laboratory. The results of the investigation were subjected to statistical analysis. The research obtained approval from the Ethics Committee of the Jagiellonian University (KBET/125/L/2013. Level of Evidence for primary research was established as type V. Results. The mean values of C-reactive protein levels in both groups were in the normal range and did not differ statistically significantly, which indicates the fact that the pain form of the temporomandibular joint disorders is not associated with inflammation of the soft tissues of the joint. Conclusion. Painful form of the temporomandibular joint dysfunctions is not connected with the inflammation of joints.

  20. Does evaluation of the ligamentous compartment enhance diagnostic utility of sacroiliac joint MRI in axial spondyloarthritis?

    DEFF Research Database (Denmark)

    Weber, Ulrich; Maksymowych, Walter P; Chan, Stanley M

    2015-01-01

    in the ligamentous compartment and their potential diagnostic utility in axial SpA. We therefore aimed to evaluate the ligamentous compartment on sacroiliac joint MRI for lesion distribution and potential incremental value towards diagnosis of SpA over and above the traditional assessment of the cartilaginous...... and ligamentous compartment. The incremental value of evaluating the ligamentous additionally to the cartilaginous compartment alone for diagnosis of SpA was graded qualitatively. We determined the lesion distribution between the two compartments, and the impact of the ligamentous compartment evaluation...... on diagnostic utility. RESULTS: MRI bone marrow lesions solely in the ligamentous compartment in the absence of lesions in the cartilaginous compartment were reported in just 0-2.0/0-4.0 % (BME/fat metaplasia) of all subjects. Additional assessment of the ligamentous compartment was regarded as essential...

  1. Evaluation of formal methods in hip joint center assessment: an in vitro analysis.

    Science.gov (United States)

    Lopomo, Nicola; Sun, Lei; Zaffagnini, Stefano; Giordano, Giovanni; Safran, Marc R

    2010-03-01

    The hip joint center is a fundamental landmark in the identification of lower limb mechanical axis; errors in its location lead to substantial inaccuracies both in joint reconstruction and in gait analysis. Actually in Computer Aided Surgery functional non-invasive procedures have been tested in identifying this landmark, but an anatomical validation is scarcely discussed. A navigation system was used to acquire data on eight cadaveric hips. Pivoting functional maneuver and hip joint anatomy were analyzed. Two functional methods - both with and without using the pelvic tracker - were evaluated: specifically a sphere fit method and a transformation techniques. The positions of the estimated centers with respect to the anatomical center of the femoral head, the influence of this deviation on the kinematic assessment and on the identification of femoral mechanical axis were analyzed. We found that the implemented transformation technique was the most reliable estimation of hip joint center, introducing a - Mean (SD) - difference of 1.6 (2.7) mm from the anatomical center with the pelvic tracker, whereas sphere fit method without it demonstrated the lowest accuracy with 25.2 (18.9) mm of deviation. Otherwise both the methods reported similar accuracy (<3mm of deviation). The functional estimations resulted in the best case to be in an average of less than 2mm from the anatomical center, which corresponds to angular deviations of the femoral mechanical axis smaller than 1.7 (1.3) degrees and negligible errors in kinematic assessment of angular displacements.

  2. Quantitative in vivo MRI evaluation of lumbar facet joints and intervertebral discs using axial T2 mapping.

    Science.gov (United States)

    Stelzeneder, David; Messner, Alina; Vlychou, Marianna; Welsch, Goetz H; Scheurecker, Georg; Goed, Sabine; Pieber, Karin; Pflueger, Verena; Friedrich, Klaus M; Trattnig, Siegfried

    2011-11-01

    To assess the feasibility of T2 mapping of lumbar facet joints and intervertebral discs in a single imaging slab and to compare the findings with morphological grading. Sixty lumbar spine segments from 10 low back pain patients and 5 healthy volunteers were examined by axial T2 mapping and morphological MRI at 3.0 Tesla. Regions of interest were drawn on a single slice for the facet joints and the intervertebral discs (nucleus pulposus, anterior and posterior annulus fibrosus). The Weishaupt grading was used for facet joints and the Pfirrmann score was used for morphological disc grading ("normal" vs. "abnormal" discs). The inter-rater agreement was excellent for the facet joint T2 evaluation (r = 0.85), but poor for the morphological Weishaupt grading (kappa = 0.15). The preliminary results show similar facet joint T2 values in segments with normal and abnormal Pfirrmann scores. There was no difference in mean T2 values between facet joints in different Weishaupt grading groups. Facet joint T2 values showed a weak correlation with T2 values of the posterior annulus (r = 0.32) This study demonstrates the feasibility of a combined T2 mapping approach for the facet joints and intervertebral discs using a single axial slab.

  3. Quantitative in vivo MRI evaluation of lumbar facet joints and intervertebral discs using axial T2 mapping

    International Nuclear Information System (INIS)

    Stelzeneder, David; Messner, Alina; Scheurecker, Georg; Goed, Sabine; Friedrich, Klaus M.; Trattnig, Siegfried; Vlychou, Marianna; Welsch, Goetz H.; Pieber, Karin; Pflueger, Verena

    2011-01-01

    To assess the feasibility of T2 mapping of lumbar facet joints and intervertebral discs in a single imaging slab and to compare the findings with morphological grading. Sixty lumbar spine segments from 10 low back pain patients and 5 healthy volunteers were examined by axial T2 mapping and morphological MRI at 3.0 Tesla. Regions of interest were drawn on a single slice for the facet joints and the intervertebral discs (nucleus pulposus, anterior and posterior annulus fibrosus). The Weishaupt grading was used for facet joints and the Pfirrmann score was used for morphological disc grading (''normal'' vs. ''abnormal'' discs). The inter-rater agreement was excellent for the facet joint T2 evaluation (r = 0.85), but poor for the morphological Weishaupt grading (kappa = 0.15). The preliminary results show similar facet joint T2 values in segments with normal and abnormal Pfirrmann scores. There was no difference in mean T2 values between facet joints in different Weishaupt grading groups. Facet joint T2 values showed a weak correlation with T2 values of the posterior annulus (r = 0.32) This study demonstrates the feasibility of a combined T2 mapping approach for the facet joints and intervertebral discs using a single axial slab. (orig.)

  4. MR imaging evaluation of plica synoviallis mediopatellaris of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Katsuyuki; Inoue, Masahiro; Murakami, Takamichi (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1992-12-01

    To evaluate the diagnostic ability of MR imaging for plica synoviallis mediopatellaris (PSM), we retrospectively reviewed the MR imaging findings of patellofemoral space in 20 knee joints of 11 patients. In all 20 knee joints, arthroscopy and MR imaging were available. MR imaging was performed with a 1.5 Tesla Magnetom (Siemens) using a round surface coil. Pulse sequences were SE (TR 600 ms/TE 26 ms), SE (TR 200 ms/TE 26,70 ms) and FLASH (TR 450 ms/TE 15 ms/FA 90deg). In six of the 20 knees with PSM proved by arthroscopy, a low intensity band was shown above the medial condyle of the femur on both T1- and T2-weighted MR images, and on FLASH images this band was shown as intermediate intensity. In the other 14 knees with no PSM observed by arthroscopy, the low intensity band was not shown on MR imaging. In all 20 knees, a similar low intensity band was shown about 1 cm cranial to the medial condyle of the femur. This should not be diagnosed as PSM. The low intensity band seen on T1- and T2-weighted MR images and its anatomical relation to the medial condyle are important in diagnosing PSM. (author).

  5. MR imaging evaluation of plica synoviallis mediopatellaris of the knee joint

    International Nuclear Information System (INIS)

    Nakanishi, Katsuyuki; Inoue, Masahiro; Murakami, Takamichi

    1992-01-01

    To evaluate the diagnostic ability of MR imaging for plica synoviallis mediopatellaris (PSM), we retrospectively reviewed the MR imaging findings of patellofemoral space in 20 knee joints of 11 patients. In all 20 knee joints, arthroscopy and MR imaging were available. MR imaging was performed with a 1.5 Tesla Magnetom (Siemens) using a round surface coil. Pulse sequences were SE (TR 600 ms/TE 26 ms), SE (TR 200 ms/TE 26,70 ms) and FLASH (TR 450 ms/TE 15 ms/FA 90deg). In six of the 20 knees with PSM proved by arthroscopy, a low intensity band was shown above the medial condyle of the femur on both T1- and T2-weighted MR images, and on FLASH images this band was shown as intermediate intensity. In the other 14 knees with no PSM observed by arthroscopy, the low intensity band was not shown on MR imaging. In all 20 knees, a similar low intensity band was shown about 1 cm cranial to the medial condyle of the femur. This should not be diagnosed as PSM. The low intensity band seen on T1- and T2-weighted MR images and its anatomical relation to the medial condyle are important in diagnosing PSM. (author)

  6. Evaluating the Joint Theater Trauma Registry as a data source to benchmark casualty care.

    Science.gov (United States)

    O'Connell, Karen M; Littleton-Kearney, Marguerite T; Bridges, Elizabeth; Bibb, Sandra C

    2012-05-01

    Just as data from civilian trauma registries have been used to benchmark and evaluate civilian trauma care, data contained within the Joint Theater Trauma Registry (JTTR) present a unique opportunity to benchmark combat care. Using the iterative steps of the benchmarking process, we evaluated data in the JTTR for suitability and established benchmarks for 24-hour mortality in casualties with polytrauma and a moderate or severe blunt traumatic brain injury (TBI). Mortality at 24 hours was greatest in those with polytrauma and a severe blunt TBI. No mortality was seen in casualties with polytrauma and a moderate blunt TBI. Secondary insults after TBI, especially hypothermia and hypoxemia, increased the odds of 24-hour mortality. Data contained in the JTTR were found to be suitable for establishing benchmarks. JTTR data may be useful in establishing benchmarks for other outcomes and types of combat injuries.

  7. Detailed Joint Region Analysis of the 7-Joint Ultrasound Score: Evaluation of an Arthritis Patient Cohort over One Year

    Directory of Open Access Journals (Sweden)

    S. Ohrndorf

    2013-01-01

    Full Text Available Objective. The main objective of this study was to evaluate the 7-joint ultrasound (US7 score by detailed joint region analysis of an arthritis patient cohort. Methods. The US7 score examines the clinically most affected wrist, MCP and PIP II, III, MTP II, and V joints for synovitis, tenosynovitis/paratenonitis, and erosions. Forty-five patients with rheumatoid arthritis (RA (84.4% and spondyloarthritis with polyarticular peripheral arthritis (PsA 13.3%; AS 2.2% with a median disease duration of 6.5 yrs (range 7.5 mths–47.6 yrs were included and examined at baseline and 3, 6, and 12 months after starting or changing therapy (DMARD/biologic. In this study, detailed US7 score joint region analysis was firstly performed. Results. The joint region analysis performed at baseline disclosed synovitis in 95.6% of affected wrists in the dorsal aspect by greyscale (GS US where Grade 2 (moderate was most often (48.9% detected. Palmar wrist regions presented Grade 1 (minor capsule elevation in 40% and Grade 2 (moderate synovitis in 37.8%. Tenosynovitis of the extensor carpi ulnaris (ECU tendon was found in 40%, with PD activity in 6.6%. Most of the erosions in MCP II were detected in the radial (68.9%, followed by the dorsal (48.9% and palmar (44.4% aspects. In MTP V, erosions were seen in 75.6% from lateral. Conclusions. Synovitis in GSUS was more often detected in the wrist in the dorsal than in the palmar aspect. ECU tendon involvement was frequent. Most erosions were found in the lateral scan of MTP V and the medial (radial scan of MCP II.

  8. Evaluation of taper joints with combined fatigue and crevice corrosion testing: Comparison to human explanted modular prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Reclaru, L., E-mail: lucien.reclaru@pxgroup.com [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Brooks, R.A. [Orthopaedic Research, Addenbrooke' s Hospital, University of Cambridge, Box 180 Hills Road, CB2 0QQ Cambridge (United Kingdom); Zuberbühler, M. [Smith and Nephew Orthopaedics AG, Schachenalle 29, 5001 Aarau (Switzerland); Eschler, P.-Y.; Constantin, F. [PX Group S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Tomoaia, G. [University of Medicine and Pharmacy Iuliu Hateganu of Cluj-Napoca, Dept. of Orthopaedics and Traumatology, Cluj-Napoca (Romania)

    2014-01-01

    The requirement for revision surgery of total joint replacements is increasing and modular joint replacement implants have been developed to provide adjustable prosthetic revision systems with improved intra-operative flexibility. An electrochemical study of the corrosion resistance of the interface between the distal and proximal modules of a modular prosthesis was performed in combination with a cyclic fatigue test. The complexity resides in the existence of interfaces between the distal part, the proximal part, and the dynamometric screw. A new technique for evaluating the resistance to cyclic dynamic corrosion with crevice stimulation was used and the method is presented. In addition, two components of the proximal module of explanted Ti6Al4V and Ti6Al7Nb prostheses were investigated by optical and electron microscopy. Our results reveal that: The electrolyte penetrates into the interface between the distal and proximal modules during cyclic dynamic fatigue tests, the distal module undergoes cracking and corrosion was generated at the interface between the two models; The comparison of the explanted proximal parts with the similar prostheses evaluated following cyclic dynamic crevice corrosion testing showed that there were significant similarities indicating that this method is suitable for evaluating materials used in the fabrication of modular prostheses. - Highlights: • Electrochemical crevice corrosion testing combined with fatigue test conducted on Ti6Al7Nb and Ti6Al4V modular prostheses • Cations released from integral prostheses • Comparison of human explanted modular prostheses with the similar prostheses evaluated in cyclic dynamic crevice corrosion.

  9. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Phiwipha Kamonrat; Duangdaun Kaenkangploo

    2002-01-01

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  10. Evaluation of interfacial microstructures in dissimilar joints of aluminum alloys to steel using nanoindentation technique

    International Nuclear Information System (INIS)

    Ogura, Tomo; Hirose, Akio; Saito, Yuichi; Ueda, Keisuke

    2009-01-01

    The characteristics of interfacial microstructures with additional elements in dissimilar 6000 system aluminum/steel joints were basically evaluated using tensile test, EPMA, TEM and nanoindentation. For Si (and Cu)-added alloy (S1 and SC), EPMA analysis showed that Si (and Cu) was enrichment in the reaction layers, which were formed during diffusion bonding. SAED pattern clarified that the reaction compounds at the interface changed from AlFe intermetalic compounds to AlFeSi intermetalic compounds by Si addition. Nanoindentation technique was successfully applied to the interfacial microstructures to understand directly the nanoscopic mechanical properties in the interfacial microstructures. The hardness and Young's modulus of Al 3 Fe intermetalic compounds was lower than those of Al 2 Fe 5 intermetalic compounds. Moreover, the hardness and Young's modulus of AlFeSi(Cu) compounds were lower than those of Al 3 Fe, indicating that the crystal system changed from orthorhombic structure to cubic structure. Joint strength of SC/steel joints was higher than that of the aluminum alloy with no additional element (Base)/ steel joint, indicating that interfacial microstructure was modified by the addition of Si and Cu to the 6000 system aluminum alloy. These results suggest that the nanoscopic mechanical properties at the interface microstructures affect greatly the macroscopic deformation behavior of the aluminum /steel dissimilar joints.

  11. Creep damage evaluation of low alloy steel weld joint by small punch creep testing

    International Nuclear Information System (INIS)

    Nishioka, Tomoya; Sawaragi, Yoshiatsu; Uemura, Hiromi

    2013-01-01

    The effect of sampling location on SPC (Small Punch Creep) tests were investigated for weld joints to establish evaluation method of Type IV creep behavior. The SPC specimen shape was 10mm diameter and 0.5mm thick round disc prepared from weld joints of 2.25Cr-1Mo low alloy steel. It was found that the center of SPC specimen should be 2mm apart from the weld interface as the recommended sampling location. Creep damage was imposed for large weld joint specimens by axial creep loading at 620degC, 52MPa with the interrupted time fraction of 0.34, 0.45, 0.64 and 0.82.SPC samples were prepared from those damaged specimens following the recommended way described in this paper. Among the various SPC tests conducted, good relationships were found for the test condition of 625degC, 200N. Namely, good relationships were obtained both between minimum deflection rate and creep life fraction, and between rupture time and creep life fraction. Consequently, creep life assessment of Type IV fracture by SPC tests could be well conducted using the sampling location and the test condition recommended in this paper. (author)

  12. Evaluation of RSA set-up from a clinical biplane fluoroscopy system for 3D joint kinematic analysis.

    Science.gov (United States)

    Bonanzinga, Tommaso; Signorelli, Cecilia; Bontempi, Marco; Russo, Alessandro; Zaffagnini, Stefano; Marcacci, Maurilio; Bragonzoni, Laura

    2016-01-01

    dinamic roentgen stereophotogrammetric analysis (RSA), a technique currently based only on customized radiographic equipment, has been shown to be a very accurate method for detecting three-dimensional (3D) joint motion. The aim of the present work was to evaluate the applicability of an innovative RSA set-up for in vivo knee kinematic analysis, using a biplane fluoroscopic image system. To this end, the Authors describe the set-up as well as a possible protocol for clinical knee joint evaluation. The accuracy of the kinematic measurements is assessed. the Authors evaluated the accuracy of 3D kinematic analysis of the knee in a new RSA set-up, based on a commercial biplane fluoroscopy system integrated into the clinical environment. The study was organized in three main phases: an in vitro test under static conditions, an in vitro test under dynamic conditions reproducing a flexion-extension range of motion (ROM), and an in vivo analysis of the flexion-extension ROM. For each test, the following were calculated, as an indication of the tracking accuracy: mean, minimum, maximum values and standard deviation of the error of rigid body fitting. in terms of rigid body fitting, in vivo test errors were found to be 0.10±0.05 mm. Phantom tests in static and kinematic conditions showed precision levels, for translations and rotations, of below 0.1 mm/0.2° and below 0.5 mm/0.3° respectively for all directions. the results of this study suggest that kinematic RSA can be successfully performed using a standard clinical biplane fluoroscopy system for the acquisition of slow movements of the lower limb. a kinematic RSA set-up using a clinical biplane fluoroscopy system is potentially applicable and provides a useful method for obtaining better characterization of joint biomechanics.

  13. Fatigue life evaluation based on welding residual stress relaxation and notch strain approach for cruciform welded joint

    International Nuclear Information System (INIS)

    Han, Jeong Woo; Han, Seung Ho; Shin, Byung Chun; Kim, Jae Hoon

    2003-01-01

    The fatigue strength of welded joint is influenced by the welding residual stress which is relaxed depending on local stress distributed in vicinity of stress raisers, eg. under cut, overlap and blow hole. To evaluate its fatigue life the geometry of the stress raisers and the welding residual stress should be taken into account. The several methods based on notch strain approach have been proposed in order to consider the two factors above mentioned. These methods, however, have shown considerable differences between analytical and experimental results. It is due to the fact that the amount of the relaxed welding residual stress evaluated by the cyclic stress-strain relationship do not correspond with that occurred in reality. In this paper the residual stress relaxation model based on experimental results was used in order to reduce the discrepancy of the estimated amount of the relaxed welding residual stress. Under an assumption of the superimposition of the relaxed welding residual stress and the local stress, a modified notch strain approach was proposed and verified to the cruciform welded joint

  14. Intramuscular ganglia arising from the superior tibiofibular joint: CT and MR evaluation

    International Nuclear Information System (INIS)

    Bianchi, S.; Abdelwahab, I.F.; Kenan, S.; Zwass, A.; Ricci, G.; Palomba, G.

    1995-01-01

    To evaluate the role of magnetic resonance imaging (MRI) and computed tomography (CT) in the diagnosis of intramuscular ganglia (IMG) that arise from the superior tibiofibular joint (STFJ). Our series consisted of three men and three women. Four patients were studied by MRI, one by CT only, and two by both modalities. Contrast was used in one of the two patients studied by CT. MRI was obtained in at least two orthogonal planes to demonstrate the relation of the ganglia to STFJ. The MR and CT appearance of these ganglia was basically that of a well-defined soft tissue mass with low attenuation on CT images consistent with the presence of fluid. On MR studies, they had an isointense signal on T1-weighted images and a homogenous high-intensity signal on T2-weighted images. MRI demonstrated the attachment of these ganglia to the STFJ. CT and MRI were effective, noninvasive modalities in the evaluation of IMG. The imaging features on both modalities were consistent with the presence of fluid-containing lesions that had close proximity and were attached to the STFJ. The combination of location and the fluid consistency of these lesions facilitated the diagnosis. (orig.)

  15. Radiologic evaluation of wrist arthrography

    International Nuclear Information System (INIS)

    Park, Yang Hee; Seong, Hyeun Lim; Yang, Jae Beom; Park, Chan Sup; Lee, Sang Seun

    1991-01-01

    Wrist arthrography allows direct visualization of the cartilage and synovial structure not seen in plain film. Arthrography of the wrist is valuable in evaluating patients with persistent wrist pain and limitation of motion after trauma. Wrist arthrography was performed in the evaluation of 30 patients with rheumatoid arthritis (2 cases), ganglions (12 cases), and wrist trauma (16 cases), and contrast media was injected in radiocarpal joint. The arthrographic findings were analyzed, and the results were as follows: In 16 patients with wrist trauma, 12 cases (75%) of compartment communication was seen including communication with distal radioulnar joint (44%), midcarpal joint (69%), and common carpometacarpal joint (63%). Of the total 30 patients, the pisiform-triquetral joint communicated with the radio carpal joint in 9 cases (30%). In 16 patients with trauma, the findings of post-traumatic arthritis included tendon communication (50%), irregular synovium (31%), and rupture of the joint capsule (25%). There was no lymphatic filling. Of 3 scaphoid fracture patients without bony callus formation, fibrous union was verified in one patient and nouncion in 2. O 12 patients with ganglion, communication between the ganglion and radiocarpal joint was seen in 2 cases and no communication in 10 cases

  16. Radiographic evaluation of perching-joint angles in cockatiels (Nymphicus hollandicus), Hispaniolan Amazon parrots (Amazona ventralis), and barred owls (Strix varia).

    Science.gov (United States)

    Bonin, Glen; Lauer, Susanne K; Guzman, David Sanchez-Migallon; Nevarez, Javier; Tully, Thomas N; Hosgood, Giselle; Gaschen, Lorrie

    2009-06-01

    Information on perching-joint angles in birds is limited. Joint immobilization in a physiologic perching angle has the potential to result more often in complete restoration of limb function. We evaluated perching-joint angles in 10 healthy cockatiels (Nymphicus hollandicus), 10 Hispaniolan Amazons (Amazona ventralis), and 9 barred owls (Strix varia) and determined intra- and interobserver variability for goniometric measurements in 2 different radiographic projections. Intra- and interobserver variation was less than 7% for all stifle and intertarsal joint measurements but frequently exceeded 10% for the hip-joint measurements. Hip, stifle, and intertarsal perching angles differed significantly among cockatiels, Hispaniolan Amazon parrots, and barred owls. The accuracy of measurements performed on straight lateral radiographic projections with superimposed limbs was not consistently superior to measurements on oblique projections with a slightly rotated pelvis. Stifle and intertarsal joint angles can be measured on radiographs by different observers with acceptable variability, but intra- and interobserver variability for hip-joint-angle measurements is higher.

  17. Evaluation of an Image-Based Tool to Examine the Effect of Fracture Alignment and Joint Congruency on Outcomes after Wrist Fracture.

    Science.gov (United States)

    Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C

    2015-01-01

    Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.

  18. Evaluation of certain veterinary drug residues in food. Seventy-eighth report of the Joint FAO/WHO Expert Committee on Food Additives.

    Science.gov (United States)

    2014-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of residues of certain veterinary drugs in food and to recommend maximum levels for such residues of food. The first part of the report considers general principles regarding the evaluation of residues of veterinary drugs within the terms of reference of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), including extrapolation of maximum residue limits (MRLs) to minor species, MRLs for veterinary drug residues in honey, MRLs relating to fish and fish species, dietary exposure assessment methodologies, the decision-tree approach to the evaluation of residues of veterinary drugs and guidance for JECFA experts. Summaries follow of the Committee's evaluations of toxicology and residue data on a variety of veterinary drugs: two anthelminthic agents (derquantel, monepantel), three antiparasitic agents (emanectin benzoate, ivermectin, lasalocid sodium), one antibacterial, antifungal and anthelminthic agent (gentian violet), a production aid (recombinant bovine somatotropins) and an adrenoceptor agonist and growth promoter (zilpaterol hydorchloride). Annexed to the report is a summary of the Committee's recommendations on these drugs, including acceptable daily intakes (ADIs)) and proposed MRLs.

  19. Evaluation of Water Content in Lumbar Intervertebral Discs and Facet Joints Before and After Physiological Loading Using T2 Mapping MRI.

    Science.gov (United States)

    Yamabe, Daisuke; Murakami, Hideki; Chokan, Kou; Endo, Hirooki; Oikawa, Ryosuke; Sawamura, Shoitsu; Doita, Minoru

    2017-12-15

    T2 mapping was used to quantify the water content of lumbar spine intervertebral discs (IVDs) and facet joints before and after physiological loading. The aim of this study was to clarify the interaction between lumbar spine IVD and facet joints as load-bearing structures by measuring the water content of their matrix after physiological loading using T2 mapping magnetic resonance imaging (MRI). To date, few reports have functionally evaluated lumbar spine IVD and facet joints, and their interaction in vivo. T2 mapping may help detect changes in the water content of IVD and articular cartilage of facet joints before and after physiological loading, thereby enabling the evaluation of changes in interacted water retention between IVD and facet joints. Twenty asymptomatic volunteers (10 female and 10 male volunteers; mean age, 19.3 years; age range, 19-20 years) underwent MRI before and after physiological loading such as lumbar flexion, extension, and rotation. Each IVD from L1/2 to L5/S1 was sliced at center of the disc space, and the T2 value was measured at the nucleus pulposus (NP), anterior annulus fibrosus (AF), posterior AF, and bilateral facet joints. In the NP, T2 values significantly decreased after exercise at every lumbar spinal level. In the anterior AF, there were no significant differences in T2 values at any level. In the posterior AF, T2 values significantly increased only at L4/5. In the bilateral facet joints, T2 values significantly decreased after exercise at every level. There was a significant decrease in the water content of facet joints and the NP at every lumbar spinal level after dynamic loading by physical lumbar exercise. These changes appear to play an important and interactional role in the maintenance of the interstitial matrix in the IVD NP and cartilage in the facet joint. 3.

  20. Ultrasonographic evaluation of degenerative changes in the distal radioulnar joint: Correlation of findings with gross anatomy and MR arthrography in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M., E-mail: florian.buck@gmail.com [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States); Nico, Marcelo A.C., E-mail: nico.marcelo@gmail.com [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States); Gheno, Ramon, E-mail: ramon.gheno@yahoo.com [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States); Trudell, Debra J., E-mail: debtrudell@hotmail.com [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States); Resnick, Donald, E-mail: dresnick@ucsd.edu [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States)

    2011-02-15

    Objective: To determine the accuracy of ultrasonography (US) in the evaluation of degenerative changes in the distal radioulnar joint (DRUJ). Methods and materials: Ten cadaveric specimens were obtained. US evaluation of cartilage degeneration and thickness was performed by two independent and blinded readers (R1 and R2). Gross anatomy and MR arthrography evaluated by two readers in consensus served as the reference standard. The joint surface not accessible to US was measured. Results: US interreader agreement was non-existent for cartilage thickness measurements and moderate for cartilage degeneration grading (weighted kappa = 0.41). Comparing US and MR imaging evaluation, there was no correlation between US R1 and MR imaging (Pearson correlation coefficient [PCC] = 0.352) and a moderate correlation between US R2 and MR imaging (PCC = 0.570) concerning cartilage thickness measurements. Concerning cartilage degeneration grading, there was a moderate to strong (R1 Spearman correlation coefficient [SCC] = 0.729)/R2 SCC = 0.767) correlation concerning cartilage degeneration grading. Comparing US and gross anatomic evaluation, there was no correlation for US R1 (PCC = 0.220) and a strong correlation for US R2 (PCC = 0.922) concerning cartilage thickness measurements, and a strong to moderate correlation (R1 SCC = 0.808/R2 SCC = 0.597) concerning cartilage degeneration grading. The mean sector of the articular surface of the ulna head not accessible to US was 13{sup o}. Conclusion: In conclusion the DRUJ is accessible to US except in the central 13{sup o} sector of the joint surface. US was approved to be sufficient in demonstrating advanced stages of cartilage degeneration. Thus, US of the DRUJ is recommended in patients suffering from ulnar-sided wrist pain.

  1. Ultrasonographic evaluation of degenerative changes in the distal radioulnar joint: Correlation of findings with gross anatomy and MR arthrography in cadavers

    International Nuclear Information System (INIS)

    Buck, Florian M.; Nico, Marcelo A.C.; Gheno, Ramon; Trudell, Debra J.; Resnick, Donald

    2011-01-01

    Objective: To determine the accuracy of ultrasonography (US) in the evaluation of degenerative changes in the distal radioulnar joint (DRUJ). Methods and materials: Ten cadaveric specimens were obtained. US evaluation of cartilage degeneration and thickness was performed by two independent and blinded readers (R1 and R2). Gross anatomy and MR arthrography evaluated by two readers in consensus served as the reference standard. The joint surface not accessible to US was measured. Results: US interreader agreement was non-existent for cartilage thickness measurements and moderate for cartilage degeneration grading (weighted kappa = 0.41). Comparing US and MR imaging evaluation, there was no correlation between US R1 and MR imaging (Pearson correlation coefficient [PCC] = 0.352) and a moderate correlation between US R2 and MR imaging (PCC = 0.570) concerning cartilage thickness measurements. Concerning cartilage degeneration grading, there was a moderate to strong (R1 Spearman correlation coefficient [SCC] = 0.729)/R2 SCC = 0.767) correlation concerning cartilage degeneration grading. Comparing US and gross anatomic evaluation, there was no correlation for US R1 (PCC = 0.220) and a strong correlation for US R2 (PCC = 0.922) concerning cartilage thickness measurements, and a strong to moderate correlation (R1 SCC = 0.808/R2 SCC = 0.597) concerning cartilage degeneration grading. The mean sector of the articular surface of the ulna head not accessible to US was 13 o . Conclusion: In conclusion the DRUJ is accessible to US except in the central 13 o sector of the joint surface. US was approved to be sufficient in demonstrating advanced stages of cartilage degeneration. Thus, US of the DRUJ is recommended in patients suffering from ulnar-sided wrist pain.

  2. Comparison of plain radiography and magnetic resonance in the evaluation of the sacroiliac joint in patients with sacroiliitis

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Ybanez, D.; Sarti, M.A.; Belloch, V.

    1996-01-01

    The Ankylosing spondylitis (AS) is an inflammatory disease involving joints and ligaments. plain radiography is an indispensable diagnostic technique in the evaluation of the sacroiliac joint, while the role of magnetic resonance (MR) is yet to be defined. Our purpose is to compare the diagnostic efficacy of plain radiography and MR in the evaluation of sacroiliac joint inflammation. We have carried out a prospective study of 43 individuals, 12 healthy volunteers (control group) and 31 patients with sacroiliitis (18 cases of confirmed AS, 11 of probable AS and 2 of condensing osteitis of the ilium). All the subjects underwent anteroposterior X-ray of pelvis and an MR study that provided two transversal sequences (SE-T2 and SE-PD) and two coronal sequences (SE-T1 and GE-T2). MR was significantly more sensitive than radiography in detecting the loss definition of the joint margins and cortical erosion (P<0.01). It was also more sensitive, although not significantly so, in the detection of subchondral sclerosis, osseous bridges and bone fusion. Erosion revealed by radiography would probably also be detected with MR(p<0.01). Despite the greater sensitivity of MR, plain X-ray should still be considered the technique of choice given its lower cost and greater availability. MR is indicated in patients without radiographic abnormalities in whom there is an evident clinical suspicion of AS. It is yet to be determined whether the greater sensitivity of MR in the detection of abnormality has any prognostic or therapeutic impact in AS patients. 15 refs

  3. Evaluation of the tarsometatarsal joint using conventional radiography, CT, and MR imaging.

    Science.gov (United States)

    Siddiqui, Nasir A; Galizia, Mauricio S; Almusa, Emad; Omar, Imran M

    2014-01-01

    The tarsometatarsal, or Lisfranc, joint complex provides stability to the midfoot and forefoot through intricate osseous relationships between the distal tarsal bones and metatarsal bases and their connections with stabilizing ligamentous support structures. Lisfranc joint injuries are relatively uncommon, and their imaging findings can be subtle. These injuries have typically been divided into high-impact fracture-displacements, which are often seen after motor vehicle collisions, and low-impact midfoot sprains, which are more commonly seen in athletes. The injury mechanism often influences the imaging findings, and classification systems based primarily on imaging features have been developed to help diagnose and treat these injuries. Patients may have significant regional swelling and pain that prevent thorough physical examination or may have other more critical injuries at initial posttrauma evaluation. These factors may cause diagnostic delays and lead to subsequent morbidities, such as midfoot instability, deformity, and debilitating osteoarthritis. Missed Lisfranc ligament injuries are among the most common causes of litigation against radiologists and emergency department physicians. Radiologists must understand the pathophysiology of these injuries and the patterns of imaging findings seen at conventional radiography, computed tomography, and magnetic resonance imaging to improve injury detection and obtain additional information for referring physicians that may affect the selection of the injury classification system, treatment, and prognosis. ©RSNA, 2014.

  4. Evaluation of the cryogenic mechanical properties of the insulation material for ITER Feeder superconducting joint

    Science.gov (United States)

    Wu, Zhixiong; Huang, Rongjin; Huang, ChuanJun; Yang, Yanfang; Huang, Xiongyi; Li, Laifeng

    2017-12-01

    The Glass-fiber reinforced plastic (GFRP) fabricated by the vacuum bag process was selected as the high voltage electrical insulation and mechanical support for the superconducting joints and the current leads for the ITER Feeder system. To evaluate the cryogenic mechanical properties of the GFRP, the mechanical properties such as the short beam strength (SBS), the tensile strength and the fatigue fracture strength after 30,000 cycles, were measured at 77K in this study. The results demonstrated that the GFRP met the design requirements of ITER.

  5. Intellectual Disability Policy as Developed, Expressed, and Evaluated in AAIDD/The Arc Joint Statements: The Role of Organization Position Statements.

    Science.gov (United States)

    Luckasson, Ruth; Ford, Marty E; McMillan, Elise D; Misilo, Frederick M; Nygren, Margaret A

    2017-07-01

    The American Association on Intellectual and Developmental Disabilities (AAIDD) and The Arc of the United States (The Arc) have a long history of joined efforts to develop, express, and evaluate disability policies. These efforts have resulted in a series of formal statements on critical issues such as education, healthcare, human rights, and criminal justice. Their joint efforts further important policy goals including providing clear strong communication about important policy values and directions, promulgating key principles of high quality supports and services, affirming best professional practices, and emphasizing personal outcomes. In addition, the joint efforts (a) affirm important aspects of organization identity; (b) enhance the organizations' abilities to assure the input of a wide variety of perspectives; (c) engage members' expanded ranges of experiences and talents; (d) multiply staff and leadership resources; (e) increase communication strength and avenues; and (f) establish processes for timely review and revision of policies as critical disability issues arise or change, and new opportunities for policy integration and advancement occur. This article describes the processes used to develop, express, and evaluate the position statements; summarizes the policy content of several joint statements; and discusses the role of these organization position statements.

  6. Evaluation of a joint Bioinformatics and Medical Informatics international course in Peru.

    Science.gov (United States)

    Curioso, Walter H; Hansen, Jacquelyn R; Centurion-Lara, Arturo; Garcia, Patricia J; Wolf, Fredric M; Fuller, Sherrilynne; Holmes, King K; Kimball, Ann Marie

    2008-01-14

    New technologies that emerge at the interface of computational and biomedical science could drive new advances in global health, therefore more training in technology is needed among health care workers. To assess the potential for informatics training using an approach designed to foster interaction at this interface, the University of Washington and the Universidad Peruana Cayetano Heredia developed and assessed a one-week course that included a new Bioinformatics (BIO) track along with an established Medical/Public Health Informatics track (MI) for participants in Peru. We assessed the background of the participants, and measured the knowledge gained by track-specific (MI or BIO) 30-minute pre- and post-tests. Participants' attitudes were evaluated both by daily evaluations and by an end-course evaluation. Forty-three participants enrolled in the course - 20 in the MI track and 23 in the BIO track. Of 20 questions, the mean % score for the MI track increased from 49.7 pre-test (standard deviation or SD = 17.0) to 59.7 (SD = 15.2) for the post-test (P = 0.002, n = 18). The BIO track mean score increased from 33.6 pre-test to 51.2 post-test (P < 0.001, n = 21). Most comments (76%) about any aspect of the course were positive. The main perceived strength of the course was the quality of the speakers, and the main perceived weakness was the short duration of the course. Overall, the course acceptability was very good to excellent with a rating of 4.1 (scale 1-5), and the usefulness of the course was rated as very good. Most participants (62.9%) expressed a positive opinion about having had the BIO and MI tracks come together for some of the lectures. Pre- and post-test results and the positive evaluations by the participants indicate that this first joint Bioinformatics and Medical/Public Health Informatics (MI and BIO) course was a success.

  7. Exemplification of Tomographic Method to Evaluate the Quality of Welded Joints Made from EN 5754-H22 Alloy

    Directory of Open Access Journals (Sweden)

    Błachnio Józef

    2016-12-01

    Full Text Available The quality of welded joints depends on many factors. The relevant standards stipulate technical conditions of welds quality assessment, which provides the basis for stating whether the given joint is compatible with the requirements or whether it is defective. In practice, making welded joints that are totally devoid of defects is extremely difficult. To conduct the control of inner structure of the given joint a non-destructive method with the application of industrial CT scanner might be applied. This modern diagnosing method combines the x-ray examination with advanced computer technology. The basic advantage of computer-assisted tomography consists in examining objects in three dimensions and the possibility to carry out three-dimensional reconstructions. The aim of this article is to discuss the use of this method to evaluate the quality of welded joints made of aluminium alloys. Capabilities of computer-assisted tomography were depicted by the case of weld probes constructed with TIG (ang. Tungsten Inert Gas welding by different process variables. One has made the analysis of the quality of probes showing the smallest and the biggest internal and external welding defects.

  8. Establishing a Research and Evaluation Capability for the Joint Medical Education and Training Campus.

    Science.gov (United States)

    Kirby, Sheila Nataraj; Marsh, Julie A; Thie, Harry J

    2011-01-01

    In calling for the transformation of military medical education and training, the 2005 Base Realignment and Closure Commission recommended relocating basic and specialty enlisted medical training to a single site to take advantage of economies of scale and the opportunity for joint training. As a result, a joint medical education and training campus (METC) has been established at Fort Sam Houston, Texas. Two of METC's primary long-term goals are to become a high-performing learning organization and to seek accreditation as a community college. Such goals require a clear model of organizational improvement with well-defined metrics for measuring its performance and using research and evaluation to assess and improve that performance. Lessons learned from a review of practices at institutions with similar missions-such as community colleges, corporate universities, the UK's Defence Medical Education and Training Agency, and other federal agencies, such as the Veterans Health Administration-establish a clear need for an office of institutional research to help METC attain its organizational goals. They also provide useful recommendations regarding the METC office's structure, scope, and governance.

  9. Property evaluation of Ni base alloy for superconducting generators and its application to seal welded joints

    International Nuclear Information System (INIS)

    Nobuhisa Suzuki; Toshiaki Murakami; Kenichi Suzuki; Satoru Asai; Minorou Tanaka; Yoshio Kobayashi

    1992-01-01

    Property requirements demanded on structural materials for rotors of superconducting generators are quite strict while there are many themes in the technical development of such materials. Components used in the cryogenic temperature are of course required to be nonmagnetic material. Additional requirements demanded on cryogenic structural materials for high response excitation superconducting generators can be summarized as follows: (1) 0.2% yield strength > 800 MPa (RT) (2) Charpy absorbed energy > 25 J (4K) (3) Electrical resistivity > 90 μΩ·cm (4K). As a candidate material which satisfy the above property requirements, we can cite precipitation-hardened Ni base alloys, for example, Inconel 718. However, production of Inconel718 is limited to about 2 tons due to problems related to segregation etc., and therefore fabrication of large-sized ingots for manufacturing generator components may be difficult. Also, there may be problems regarding weldability, especially from the viewpoint of microcracking in the heat affected zone, among strength-supporting parts or the parts requiring functional capability such as seal welded joints. Under such background circumstances, we conducted studies on chemical composition by considering producibility of large-sized ingots and weldability of the alloy as well as property evaluations of materials incorporating such requirements. Further, included in this paper are the application of the alloy to seal welded joints and its unified fatigue strength evaluation method

  10. Evaluation of cartilage repair tissue in the knee and ankle joint using sodium magnetic resonance imaging at 7 Tesla

    International Nuclear Information System (INIS)

    Zbyn, S.

    2015-01-01

    Articular cartilage of adults shows no or very limited intrinsic capacity for self-repair. Since untreated chondral defects often progress to osteoarthritis, symptomatic defects should be treated. Different cartilage repair procedures have been developed with the goal to restore joint function and prevent further cartilage degeneration by providing repair tissue of the same structure, composition, and biomechanical properties as native cartilage. Various cartilage repair procedures have been developed; including bone marrow stimulation (BMS) techniques such as microfracture (MFX), cell-based techniques such as matrix-associated autologous chondrocyte transplantation (MACT), and others. Since biopsies of cartilage repair tissue are invasive and cannot be repeated, a noninvasive method is needed that could follow-up the quality of cartilage and repair tissue. Negatively charged glycosaminoglycans (GAG) are very important for cartilage function as they attract positive ions such as sodium. The high concentration of ions in cartilage is responsible for osmotic pressure providing cartilage its resilience to compression. Since GAGs are counterbalanced by sodium ions, sodium magnetic resonance imaging (MRI) was validated as a sensitive method for the in vivo evaluation of GAG concentration in native cartilage but not for repair tissue. Thus, the main goal of this thesis was to optimize and validate sodium 7 Tesla MRI for the evaluation of cartilage repair tissue quality in patients after different cartilage repair surgeries in the knee and ankle joint. In our studies, sodium MRI was used for the first time for the clinical evaluation of cartilage repair tissue. A strong correlation found between sodium imaging and dGEMRIC (another GAG-sensitive technique) in patients after MACT on femoral cartilage proved sensitivity of sodium MRI to GAG changes in native cartilage and repair tissue in vivo. Comparison between BMS and MACT patients showed significantly lower sodium values

  11. 40 CFR 35.515 - Evaluation of performance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Evaluation of performance. 35.515 Section 35.515 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....515 Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional...

  12. Experimental Design for Evaluation of Co-extruded Refractory Metal/Nickel Base Superalloy Joints

    International Nuclear Information System (INIS)

    ME Petrichek

    2005-01-01

    a critical thickness (0.0005 in.). A diffusion barrier that exceeded this thickness would likely fail. The joint fabrication method must therefore mechanically bond the two materials causing little or no interdiffusion upon formation. Co-extrusion fits this description since it forms a mechanical joint between two materials by using heat and pressure. The two materials to be extruded are first assembled and sealed within a co-extrusion billet which is subsequently heated and then extruded through a die. For a production application, once the joint is formed, it is dejacketed to remove the outer canister. The remaining piece consists of two materials bonded together with a thin diffusion barrier. Therefore, the long-term stability of the joint is determined primarily by the kinetics of interdiffusion reaction between the two materials. An experimental design for co-extrusion of refractory metals and nickel-based superalloys was developed to evaluate this joining process and determine the long-term stability of the joints

  13. 40 CFR 35.115 - Evaluation of performance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Evaluation of performance. 35.115 Section 35.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL... Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional Administrator will...

  14. Radiographic evaluation of degenerative joint disease in horses: interpretive principles

    International Nuclear Information System (INIS)

    Widmer, W.R.; Blevins, W.E.

    1994-01-01

    Degenerative joint disease in horses is characterized by the progressive deterioration of articular cartilage of synovial joints. The morbidity associated with degenerative joint disease, particularly the loss of function in pleasure and performance horses, costs horse owners millions of dollars each year. Although new drugs, such as polysulfated glycosaminoglycans and hyaluronic acid, are available for the treatment of patients with degenerative joint disease, the success of therapy depends on early diagnosis. Diagnostic imaging strategies, therefore, should focus on accurate and timely diagnosis of degenerative joint disease to provide prompt therapy. Early identification of degenerative joint disease is also beneficial because the use and/or training methods of affected patients may be altered, possibly limiting the progression of the disease. The pathogenesis of degenerative joint disease is complex and multifactorial. Current evidence suggests that initiating factors lead to a final common pathway-breakdown of articular cartilage. There are many diagnostic tests that aid practitioners in detecting degenerative joint disease; however, the most important imaging technique is radiography. During the early stages of the disease, radiographic changes may be slight; therefore, it is essential that practitioners have adequate equipment to obtain high-quality radiographs. Thinning of the joint space, osteophytosis, enthesopathy, changes in subchondral bone, and increased synovium and synovia provide radiographic evidence of degenerative joint disease. By understanding the pathophysiology of the disease and how technical alterations affect the subtle radiographic changes, practitioners can more accurately diagnose degenerative joint disease during its early stages and institute proper therapy

  15. Developing Indicators for Monitoring and Evaluating Joint Management Effectiveness in Protected Areas in the Northern Territory, Australia

    Directory of Open Access Journals (Sweden)

    Arturo Izurieta

    2011-09-01

    We consider the effectiveness of a participatory process within the context of the relationships, capacities, skills, communication, and cross-cultural information sharing. We found that at the early stages of joint management, the partners mostly identify process indicators related to human and social capital assets. Cross-cultural engagement in the early stages of the monitoring and evaluation cycle is challenged by issues relating to communication, institutional and community capacities, representation, and flexibility in ways of working together while learning by doing. We conclude, however, that a participatory monitoring and evaluation approach in which partners agree equally on the identification of criteria and indicators to measure agreed management outcomes has the potential of improving equitable participation, decision making and working relationships, which in turn will lead to improved park management effectiveness and community outcomes.

  16. Modeling of correlated data with informative cluster sizes: An evaluation of joint modeling and within-cluster resampling approaches.

    Science.gov (United States)

    Zhang, Bo; Liu, Wei; Zhang, Zhiwei; Qu, Yanping; Chen, Zhen; Albert, Paul S

    2017-08-01

    Joint modeling and within-cluster resampling are two approaches that are used for analyzing correlated data with informative cluster sizes. Motivated by a developmental toxicity study, we examined the performances and validity of these two approaches in testing covariate effects in generalized linear mixed-effects models. We show that the joint modeling approach is robust to the misspecification of cluster size models in terms of Type I and Type II errors when the corresponding covariates are not included in the random effects structure; otherwise, statistical tests may be affected. We also evaluate the performance of the within-cluster resampling procedure and thoroughly investigate the validity of it in modeling correlated data with informative cluster sizes. We show that within-cluster resampling is a valid alternative to joint modeling for cluster-specific covariates, but it is invalid for time-dependent covariates. The two methods are applied to a developmental toxicity study that investigated the effect of exposure to diethylene glycol dimethyl ether.

  17. The diabetic foot: Magnetic resonance imaging evaluation

    International Nuclear Information System (INIS)

    Beltran, J.; Campanini, D.S.; Knight, C.; McCalla, M.

    1990-01-01

    Fourteen diabetic patients with suspected foot infection and/or neuropathic joint (Charcot Joint) were evaluated with magnetic resonance imaging (MRI) in an attempt to assess the extent of the infection and also to distinguish infection from the changes seen with neuroarthropathy. The majority of patients with infection had more than one site of involvement and the following diagnoses were made by MRI evaluation: Osteomyelitis (n=8), abscess (n=7), neuropathic joint (n=5), septic arthritis (n=4), and tenosynovitis (n=4). Clinical or surgical/pathological confirmation of the MRI diagnoses was obtained in all but nine sites of infection or cases of neuropathic joint. If the two diagnostic categories of septic arthritis and tenosynovitis are excluded, all but four of the MRI diagnoses were confirmed. A distinctive pattern for neuroarthropathy was identified in five cases, consisting of low signal intensity on T1- and T2-weighted images within the bone marrow space adjacent to the involved joint. We conclude that MRI is a valuable adjunct in the evaluation of the diabetic foot, and that it provides accurate information regarding the presence and extent of infection in this subset of patients. MRI has proven particularly helpful in differentiating neuroarthropathy from osteomyelitis. (orig.)

  18. Evaluating the microsoft kinect skeleton joint tracking as a tool for home-based physiotherapy

    Directory of Open Access Journals (Sweden)

    Phommahavong Somphong

    2015-09-01

    Full Text Available In physiotherapy, rehabilitation outcome is majorly dependent on the patient to continue exercises at home. To support a continuous and correct execution of exercises composed by the physiotherapist it is important that the patient stays motivated. With the emergence of game consoles such as Nintendo Wii, PlayStation Eye or Microsoft Kinect that employ special controllers or camera based motion recognition as means of user input those technologies have also been found to be interesting for other real-life applications such as providing individual physiotherapy exercises and an encouraging rehabilitation routine. Due to the intended use of those motion tracking systems in a computer-game environment it remains questionable if the accuracy of the skeleton joint tracking hardware and algorithms is suflicient for physiotherapy applications. We present a basic evaluation of the joint tracking accuracy where angles between various body extremities calculated by a Kinect system were compared with a high resolution motion capture system. Results show promising results with tracking deviations between 2.7° and 14.2° with a mean of the absolute deviations of 8.7°.

  19. Power Doppler Ultrasound Evaluation of Peripheral Joint, Entheses, Tendon, and Bursa Abnormalities in Psoriatic Patients: A Clinical Study.

    Science.gov (United States)

    Tang, Yuanjiao; Yang, Yujia; Xiang, Xi; Wang, Liyun; Zhang, Lingyan; Qiu, Li

    2018-04-15

    To evaluate the prevalence rates of peripheral joint, enthesis, tendon, and bursa abnormalities by power Doppler (PD) ultrasonic examination in patients with psoriatic arthritis (PsA), psoriatic patients without clinical signs of arthritis (non-PsA psoriasis group), and healthy individuals, to detect subclinical PsA. A total of 253 healthy volunteers, 242 non-PsA psoriatic patients, and 86 patients with PsA were assessed by 2-dimensional and power Doppler (PD) ultrasound. Peripheral joint, enthesis, tendon, and bursa abnormalities were observed, characterizing abnormal PD. The affected patients and sites with abnormalities in various ages were compared among groups; PD signal grades for the abnormalities were also compared. In the PsA group, significantly higher percentages of sites showing joint effusion/synovitis, enthesitis, and tenosynovitis in all age groups, and markedly higher rates of sites with bursitis were found in young and middle age groups, compared with the non-PsA and control groups (all p the non-PsA group showed significantly higher rates of joint effusion/synovitis and enthesitis sites, and elevated PD signal grades of synovitis, enthesitis, and tenosynovitis in comparison with the control group, both in young and middle age groups (all p tenosynovitis.

  20. Arthroscopic evaluation of patellofemoral congruence with rotation of the knee joint and electrical stimulation of the quadriceps.

    Science.gov (United States)

    Suganuma, Jun; Mochizuki, Ryuta; Inoue, Yutaka; Kitamura, Kazuya; Honda, Akio

    2014-02-01

    The aim of this study was to investigate the pathoanatomic features of patellar instability by arthroscopically comparing patellofemoral congruence with rotation of the knee joint and/or electrical stimulation of the quadriceps (ESQ) between knees with and without patellar instability. We retrospectively examined 83 knee joints in 83 patients. The joints were classified into 2 groups: group 1 comprised those without a history of patellar dislocation and included 59 patients (25 male and 34 female patients), and group 2 comprised those with a history of patellar dislocation and included 24 patients (9 male and 15 female patients). Evaluation of patellofemoral congruence at 30° of flexion of the knee joint was conducted based on an axial radiograph and arthroscopic findings. The congruence angle was measured on the radiograph. The position of the patellar central ridge (PPCR) on the trochlear groove during arthroscopy was measured using still video frames of knee joints with rotational stress and/or ESQ. Statistical differences in the measurements between the 2 groups were assessed with the unpaired t test and the area under the receiver operating characteristic curve of each measurement. There were significant differences (P congruence angle on radiographs and PPCR in knee joints with rotational stress and/or ESQ on arthroscopy. External and internal rotation of the knee joint caused lateral and medial patellar shift, respectively, in both groups, but the shift was significantly larger in group 2. ESQ in addition to rotation caused further patellar shift in group 2 but reduced patellar shift in group 1. Measurement of PPCR with external rotation of the knee and ESQ was the only method to show an area under the receiver operating characteristic curve of 1. There were significant differences in the effects of rotation of the knee joint and/or ESQ on patellofemoral congruence at 30° of flexion of the knee joint on arthroscopy between knees with and without patellar

  1. Evaluation of the Efficacy of Different Concentrations of Dextrose Prolotherapy in Temporomandibular Joint Hypermobility Treatment.

    Science.gov (United States)

    Mustafa, Rawand; Güngörmüş, Metin; Mollaoğlu, Nur

    2018-03-12

    The aim of this study was to compare and evaluate the efficacy of different concentrations of dextrose prolotherapy for the treatment of temporomandibular joint (TMJ) hypermobility. A prospective, randomized clinical trial including patients with subluxation or dislocation was performed. The study comprised 40 patients. Patients were randomly divided into 4 groups: control group, 10% dextrose, 20% dextrose, and 30% dextrose group. Patients in all groups received injections into 4 different areas of each TMJ in 4 sessions at monthly intervals. Visual analog scale of TMJ pain intensity, maximum mouth opening (MMO), joint sounds, and frequency of luxations were recorded preoperatively and postoperatively after 1 month of last injection. The collected data were then statistically analyzed. Each group showed postoperatively significant improvement in TMJ pain, significant decrease in both MMO and joint sound. Besides that, TMJ locking was not observed in any patient during the follow-up period. There were no statistically significant differences throughout the study intervals between the groups. It was concluded that there was no significant difference between control group and dextrose groups and there is no superiority of any concentration of dextrose over the others in TMJ prolotherapy, and all treatment procedures were efficient in improvement of clinical symptoms related to TMJ hypermobility. If dextrose is used as a proliferant, it can be said that 10% dextrose can be sufficient in TMJ hypermobility treatment.

  2. Joint diseases

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The authors discuss how x-ray examination is essential in the diagnosis and evaluation of the arthritides. Most arthritides are first suspected by the clinician, and x-ray evaluation of these entities along with laboratory testing is important for confirmation of the clinical diagnosis and in staging of the disease process. Several arthritides are often diagnosed first by the podiatrist on x-ray evaluation, including pseudogout, ankylosing spondylitis, early rheumatoid arthritis, degenerative joint disease, and tuberculosis of bone. The joint responds to insult in only a limited number of ways that become apparent on x-ray. The soft tissues surrounding the joint, the articulating bones, and alignment of the joint space may all be involved by the arthritic process. On roentgenographic examination, the soft tissues must be examined for edema, masses, calcifications, and atrophy. The articulating bones must be examined for demineralization, erosions, osteophytes, periosteal reaction, cysts and sclerosis

  3. Evaluation of Patient-Oriented Standards of Joint Commission International in Gilan and Mazandaran Teaching Hospitals

    Directory of Open Access Journals (Sweden)

    Ghaseminejhad

    2016-08-01

    Full Text Available Background Medical tourism, a multi-million-dollar industry, has had a significant effect in economic flourishing, creating jobs, and preventing the outflow of currency. Objectives The aim of this study was to evaluate teaching hospitals affiliated to Gilan and Mazandaran University of Medical Sciences, according to joint commission international (JCI standards. Methods This was a descriptive cross sectional study conducted among teaching hospitals affiliated to Gilan and Mazandaran University of Medical Sciences during year 2015. To collect data and evaluate the hospitals, patient-oriented standards of JCI was applied. Results Amongst the eight standards, international patient safety goals (IPSG (with a score of 87.5% had the highest, and patient and family education (PFE (with a score of 53.75% had the lowest score. Hospital “4” with a score of 90.41%, had the highest, and hospital “7” with 58.90%, had the lowest rate of compliance to the standards. According to the Mann-Whitney test, the observed statistics considering a P value of ≤ 0.05 level, was not significant, therefore on a 95% certainty level, there was no significant difference between hospitals in Gilan and Mazandaran, regarding compliance with standards. Overall, the hospitals under study were relatively prepared for attracting medical tourists. Conclusions According to the results, it seems that more planning and implementation of projects is required to strengthen the axes of the joint commission regarding accreditation of hospitals and attraction of medical tourists to these centers, especially foreign tourists. Researchers are recommended to pay special attention to the university of medical sciences of two provinces for the establishment of standards and utilization of professional consultants.

  4. JEFF 3.1.2 - Joint evaluated nuclear data library for fission and fusion applications - February 2012 (DVD)

    International Nuclear Information System (INIS)

    2012-02-01

    The Joint Evaluated Fission and Fusion File (JEFF) project is a collaboration between NEA Data Bank member countries. The JEFF library combines the efforts of the JEFF and EFF/EAF Working Groups to produce a common sets of evaluated nuclear data, mainly for fission and fusion applications. The JEFF-3.1.2 version, released in February 2012, contains a number of different data types, including neutron and proton interaction data, radioactive decay data, fission yields, and thermal scattering law data. Currently, JEFF-3.1.2 data are available in ENDF-6 format (neutron library) from the Web. This new release is an update from JEFF-3.1.1 which concerns 115 material files from the general purpose incident neutron library which have been modified since JEFF-3.1.1. Modifications include: Hf isotopes: 6 new Hf evaluations have replaced previous ones; Gamma production data from neutron capture (MF=6 MT=102) has been added to 89 fission products (FP) evaluations; 47 of these FP have been replaced by ENDF-B/VII.0 evaluations, with gamma data added in this release. Corrections from JEFF-Beta feedback have been incorporated for 15 materials. Corrections that solve NJOY covariance processing problems and JANIS warnings have been made to 6 files. This DVD contains: - General purpose incident neutron data in ENDF-6 and ACE formats; - Activation data; - Thermal scattering data; - Incident proton data; - Radioactive decay data; - Neutron-induced fission yields data; - Spontaneous fission yields data

  5. Screen-film versus digital radiography of sacroiliac joints: Evaluation of image quality and dose to patients

    International Nuclear Information System (INIS)

    Jablanovic, D.; Ciraj-Bjelac, O.; Damjanov, N.; Seric, S.; Radak-Perovic, M.; Arandjic, D.; Maksimovic, R.

    2013-01-01

    The purpose of this paper is to evaluate the image quality and dose to patients in the radiography of sacroiliac joints and to perform a clinical comparative study of digital and conventional screen-film radiography. Routine radiography of sacroiliac joint was performed in 60 patients using digital and screen-film radiography. The visibility of five anatomical regions and the overall image quality were rated by experienced radiologists. Patient dose assessment in terms of entrance surface air kerma (ESAK) was performed. The digital system showed slightly improved visualisation of specific anatomical structures. Overall image quality was significantly better in the digital when compared with the screen-film imaging system. The average ESAK was 2.4 mGy in screen-film and 3.6 mGy in digital radiography. The digital radiography provided equal or better visibility of anatomical details and overall image quality, but on higher dose levels. Therefore, the practice on digital systems must be optimised. (authors)

  6. Evaluation of certain veterinary drug residues in food. Eighty-first report of the Joint FAO/WHO Expert Committee on Food Additives.

    Science.gov (United States)

    2016-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of residues of certain veterinary drugs in food and to recommend maximum levels for such residues in food. The first part of the report considers general principles regarding the evaluation of residues of veterinary drugs within the terms of reference of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), including MRLs for generic fish species, acute reference doses (ARfDs) for veterinary drugs, an approach for dietary exposure assessment of compounds used for multiple purposes (i.e veterinary drugs and pesticides), dietary exposure assessment for less-than-lifetime exposure, and the assessment of short-term (90-day and 12-month) studies in dogs. Summaries follow of the Committee's evaluations of toxicological and residue data on a variety of veterinary drugs: two insecticides (diflubenzuron and teflubenzuron), an antiparasitic agent (ivermectin), an ectoparasiticide (sisapronil) and a β2-adrenoceptor agonist (zilpaterol hydrochloride). In addition, the Committee considered issues raised in concern forms from the Codex Committee on Residues of Veterinary Drugs in Foods on lasalocid sodium, an antiparasitic agent. Annexed to the report is a summary of the Committee's recommendations on these drugs, including acceptable daily intakes (ADIs), ARfDs and proposed MRLs.

  7. Temporomandibular joint movement; Evaluation of protrusive splint therapy with GRASS MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, M.; Itou, S.; Ishii, Y.; Yamamoto, K.; Kawamura, Y.; Matsuda, T.; Hayashi, N.; Ishii, J. (Dept. of Radiology, Dept. of Oral and Maxillofacial Surgery, Fukui Medical School (Japan))

    1992-09-01

    Ten temporomandibular joints (TMJs) of 5 healthy volunteers and 19 TMJs of internal derangements in 16 patients with splint therapy were examined with MR imaging. T1-weighted images were obtained only in the closed mouth position, and gradient recalled acquisition in steady state (GRASS) images were obtained in active opening and closing phases, allowing a pseudodynamic display of TMJ movement. All patients received protrusive splint treatment. The usefulness of MR imaging to assess the efficacy of splint therapy was evaluated. Corrected disk position with the splint in place was clearly demonstrated in 9 TMJs, corresponding with elimination of reciprocal clicking. Ten other TMJs of anterior disk displacement without reduction showed uncorrected disk position by the splint. This information could confirm the therapeutic efficacy, or suggest other treatment alternatives. GRASS MR imaging can provide accurate and physiologic information about disk function in initial and follow-up assessment of protrusive splint therapy. (orig.).

  8. Evaluation on joint toxicity of chlorinated anilines and cadmium to Photobacterium phosphoreum and QSAR analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hao, E-mail: realking163@163.com [School of Life and Chemistry, Jiangsu Second Normal University, Nanjing, Jiangsu 210013 (China); Wang, Chao; Shi, Jiaqi [State Key Laboratory of Pollution Control and Resources Reuse, School of Environment, Nanjing University, Nanjing, Jiangsu 210023 (China); Chen, Lei [School of Life and Chemistry, Jiangsu Second Normal University, Nanjing, Jiangsu 210013 (China)

    2014-08-30

    Highlights: • Cd has different effects on joint toxicity when in different concentrations. • The toxicity of most binary mixtures decreases when Cd concentration rises. • Different QSAR models are developed to predict the joint toxicity. • Descriptors in QSARs can help to elucidate the joint toxicity mechanism. • Van der Waals’ force or complexation may reduce the toxicity of mixtures. - Abstract: The individual IC{sub 50} (the concentrations causing a 50% inhibition of bioluminescence after 15 min exposure) of cadmium ion (Cd) and nine chlorinated anilines to Photobacterium phosphoreum (P. phosphoreum) were determined. In order to evaluate the combined effects of the nine chlorinated anilines and Cd, the toxicities of chlorinated anilines combined with different concentrations of Cd were determined, respectively. The results showed that the number of chlorinated anilines manifesting synergy with Cd decreased with the increasing Cd concentration, and the number manifesting antagonism decreased firstly and then increased. The joint toxicity of mixtures at low Cd concentration was weaker than that of most binary mixtures when combined with Cd at medium and high concentrations as indicated by TU{sub Total}. QSAR analysis showed that the single toxicity of chlorinated anilines was related to the energy of the lowest unoccupied molecular orbital (E{sub LUMO}). When combined with different concentrations of Cd, the toxicity was related to the energy difference (E{sub HOMO} − E{sub LUMO}) with different coefficients. Van der Waals’ force or the complexation between chlorinated anilines and Cd had an impact on the toxicity of combined systems, which could account for QSAR models with different physico-chemical descriptors.

  9. Evaluation of brazing joint of graphites and molybdenum

    International Nuclear Information System (INIS)

    Ishiyama, Shintarou; Kodaira, Tsuneo; Oku, Tatsuo

    1991-01-01

    Bonding test of six kinds of graphites to molybdenum was performed in the following conditions: Brazing elements was obtained by mixing of titanium nickel and copper in the range of 90∼51w%, 40∼10w%, 31∼0w%, respectively. Nonpressed brazing was performed at maximum temperature 1,000degC in a vacuum. Strength tests of these brazed joints were done in the conditions of at high temperature up to, 1,100degC in a vacuum, after 200 heat cycles from room temperature to about 900degC. Optical observation were performed before and after electron beam tests at 3.0 kW/cm 2 ·0.1 s·5 shots. The following results were derived: (1) The good mixing condition was found for titanium, nickel and copper brazing material at 64, 23 and 13w%, respectively. (2) Bending strengths of the brazed joints at room temperature were found to be proportional to the bending strengths of the graphite. (3) Bending strengths of the brazed joints shows no change until tested temperature reached 900degC in a vacuum. (4) Bending strength of the brazed joints showed no change after 200 heat cycles in the temperature range of room ∼ about 900degC and the electron beam tests. (author)

  10. Evaluation of strength property variations across 9Cr-1Mo steel weld joints using automated ball indentation (ABI) technique

    International Nuclear Information System (INIS)

    Nagaraju, S.; GaneshKumar, J.; Vasantharaja, P.; Vasudevan, M.; Laha, K.

    2017-01-01

    The variations of strength properties across 9Cr-1Mo steel weld joints fabricated by different arc welding processes such as shielded metal arc welding (SMAW), tungsten inert gas (TIG) and activated tungsten inert gas (A-TIG) have been evaluated employing automatic ball indentation (ABI) technique. ABI tests were conducted at 298 K across various zones of the weld joints comprising of base metal, weld metal, heat affected zone (HAZ) and intercritical HAZ (ICHAZ) regions. The flow curves obtained from ABI tests were correlated with corresponding conventional tensile test results. In general, the tensile strength decreased systematically across the weld joint from weld metal to base metal. Inter critical HAZ exhibited the least strength implying that it is the weakest zone. The incomplete phase transformation in the ICHAZ during weld thermal cycle caused the softening. The A-TIG weld metal exhibited higher UTS and strain hardening values due to higher carbon in the martensite. The strain hardening exponent exhibited only slight variation across the various regions of the weld joints. A-TIG weld joint exhibited higher weld metal and HAZ strength, marginally higher UTS to YS ratio in the weld metal and HAZ compared to that of the other two processes. Hence, among the three welding processes chosen, A-TIG welding process is found to be superior in producing a 9Cr-1Mo steel weld joint with better strength properties.

  11. Evaluation of strength property variations across 9Cr-1Mo steel weld joints using automated ball indentation (ABI) technique

    Energy Technology Data Exchange (ETDEWEB)

    Nagaraju, S. [Nuclear Recycle Board, BARCF, Kalpakkam (India); GaneshKumar, J.; Vasantharaja, P. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India); Vasudevan, M., E-mail: dev@igcar.gov.in [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India); Laha, K. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    2017-05-17

    The variations of strength properties across 9Cr-1Mo steel weld joints fabricated by different arc welding processes such as shielded metal arc welding (SMAW), tungsten inert gas (TIG) and activated tungsten inert gas (A-TIG) have been evaluated employing automatic ball indentation (ABI) technique. ABI tests were conducted at 298 K across various zones of the weld joints comprising of base metal, weld metal, heat affected zone (HAZ) and intercritical HAZ (ICHAZ) regions. The flow curves obtained from ABI tests were correlated with corresponding conventional tensile test results. In general, the tensile strength decreased systematically across the weld joint from weld metal to base metal. Inter critical HAZ exhibited the least strength implying that it is the weakest zone. The incomplete phase transformation in the ICHAZ during weld thermal cycle caused the softening. The A-TIG weld metal exhibited higher UTS and strain hardening values due to higher carbon in the martensite. The strain hardening exponent exhibited only slight variation across the various regions of the weld joints. A-TIG weld joint exhibited higher weld metal and HAZ strength, marginally higher UTS to YS ratio in the weld metal and HAZ compared to that of the other two processes. Hence, among the three welding processes chosen, A-TIG welding process is found to be superior in producing a 9Cr-1Mo steel weld joint with better strength properties.

  12. Histopathologic evaluation of the effects of etodolac in established adjuvant arthritis in rats: evidence for reversal of joint damage.

    Science.gov (United States)

    Weichman, B M; Chau, T T; Rona, G

    1987-04-01

    Histopathologic evaluation of hindpaws from control rats with established adjuvant arthritis showed severe alterations in soft tissue and bone, as well as progressive, moderate-to-severe articular changes. Following treatment with etodolac for 28 days, soft tissue and articular changes were rated mild, and bone changes were rated moderate, but with remodeling. These findings indicate that etodolac partially reversed the joint damage in these rats.

  13. Numerical evaluation of multipass welding temperature field in API 5L X80 steel welded joints

    Directory of Open Access Journals (Sweden)

    J Nóbrega

    2016-10-01

    Full Text Available Many are the metallurgical changes suffered by materials when subjected to welding thermal cycle, promoting a considerable influence on the welded structures thermo mechanical properties. In project phase, one alternative for evaluating the welding cycle variable, would be the employment of computational methods through simulation. So, this paper presents an evaluation of the temperature field in a multipass welding of API 5L X80 steel used for oil and gas transportation, using the ABAQUS ® software, based on Finite Elements Method (FEM. During the simulation complex phenomena are considerable including: Variation in physical and mechanical properties of materials as a function of temperature, welding speed and the different mechanisms of heat exchange with the environment (convection and radiation were used. These considerations allow a more robust mathematical modeling for the welding process. An analytical heat source proposed by Goldak, to model the heat input in order to characterize the multipass welding through the GTAW (Gas Tungsten Arc Welding process on root and the SMAW (Shielded Metal Arc Welding process for the filling passes were used. So, it was possible to evaluate the effect of each welding pass on the welded joint temperature field, through the temperature peaks and cooling rates values during the welding process.

  14. SU-E-T-171: Evaluation of the Analytical Anisotropic Algorithm in a Small Finger Joint Phantom Using Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Chow, J; Owrangi, A; Jiang, R

    2014-01-01

    Purpose: This study investigated the performance of the anisotropic analytical algorithm (AAA) in dose calculation in radiotherapy concerning a small finger joint. Monte Carlo simulation (EGSnrc code) was used in this dosimetric evaluation. Methods: Heterogeneous finger joint phantom containing a vertical water layer (bone joint or cartilage) sandwiched by two bones with dimension 2 × 2 × 2 cm 3 was irradiated by the 6 MV photon beams (field size = 4 × 4 cm 2 ). The central beam axis was along the length of the bone joint and the isocenter was set to the center of the joint. The joint width and beam angle were varied from 0.5–2 mm and 0°–15°, respectively. Depth doses were calculated using the AAA and DOSXYZnrc. For dosimetric comparison and normalization, dose calculations were repeated in water phantom using the same beam geometry. Results: Our AAA and Monte Carlo results showed that the AAA underestimated the joint doses by 10%–20%, and could not predict joint dose variation with changes of joint width and beam angle. The calculated bone dose enhancement for the AAA was lower than Monte Carlo and the depth of maximum dose for the phantom was smaller than that for the water phantom. From Monte Carlo results, there was a decrease of joint dose as its width increased. This reflected the smaller the joint width, the more the bone scatter contributed to the depth dose. Moreover, the joint dose was found slightly decreased with an increase of beam angle. Conclusion: The AAA could not handle variations of joint dose well with changes of joint width and beam angle based on our finger joint phantom. Monte Carlo results showed that the joint dose decreased with increase of joint width and beam angle. This dosimetry comparison should be useful to radiation staff in radiotherapy related to small bone joint

  15. Evaluating violence reduction efforts in South Africa | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2015-07-10

    Jul 10, 2015 ... Evaluating complex violence reduction interventions poses a wide ... Skip to main content ... and local government aimed at evaluating the violence reduction impact of VPUU. Researchers reflect on the challenges of developing and implementing an evaluation framework to measure the impact of this joint ...

  16. Student perspectives on the development and evaluation of a joint international education to promote employability in Europe.

    Science.gov (United States)

    Craig, Claire; Piškur, Barbara

    2012-01-01

    This article presents a student evaluation of a joint international education developed as part of a European project which sought to equip health care practitioners with the skills to support employability of individuals furthest removed from the labour market, disadvantaged on account of age, gender, migration or ethnicity. Thirty eight students out of the forty one students that participated in the pilot of four modules (NL, UK, SE, DE) returned completed digital questionnaires (92.6% response rate). The study is descriptive by nature. A questionnaire was used to collect the data from students. Additionally students attending the module in the UK also took part in a series of qualitative interviews which sought to explore their experiences in more detail. These were recorded, transcribed and analyzed. Students reported that joint education facilitates competence development. The competencies they identified (Information Communications Technology) were recognised as being key to enhancing employability of disadvantaged groups. The joint international education exemplified by EEE4all offers one model of how to build a responsive international curriculum to ensure that the workforce of the future is well placed to meet the needs of this changing world.

  17. Computed tomography evaluation of the sacroiliac joints in Crohn disease

    International Nuclear Information System (INIS)

    Scott, W.W. Jr.; Fishman, E.K.; Kuhlman, J.E.; Caskey, C.I.; O'Brien, J.J.; Walia, G.S.; Bayless, T.M.

    1990-01-01

    Computed tomography (CT) was used in a prospective study of the sacroiliac joints in 86 patients with Crohn disease to determine the type and frequency of sacroiliac joint abnormalities present in this population. The CT findings were correlated with review of the clinical history in 64 patients. Computed tomography demonstrated changes of sacroiliitis in 29% of the study group. This high prevalence of sacroiliac joint abnormality was found even in those under 30 years of age. It exceeds the 11-19% previously reported from plain film examination, reflecting the greater sensitivity of CT. In the subgroup of 64 patients studied clinically, 19 (30%) had abnormal sacroiliac joints on CT, but only 2 (3%) reported symptoms related to the sacroiliac joints. (orig.)

  18. An Evaluation of Global and Local Tensile Properties of Friction-Stir Welded DP980 Dual-Phase Steel Joints Using a Digital Image Correlation Method.

    Science.gov (United States)

    Lee, Hyoungwook; Kim, Cheolhee; Song, Jung Han

    2015-12-04

    The effect of the microstructure heterogeneity on the tensile plastic deformation characteristic of friction-stir-welded (FSW) dual-phase (DP) steel was investigated for the potential applications on the lightweight design of vehicles. Friction-stir-welded specimens with a butt joint configuration were prepared, and quasi-static tensile tests were conducted, to evaluate the tensile properties of DP980 dual-phase steels. The friction-stir welding led to the formation of martensite and a significant hardness rise in the stir zone (SZ), but the presence of a soft zone in the heat-affected zone (HAZ) was caused by tempering of the pre-existing martensite. Owing to the appearance of severe soft zone, DP980 FSW joint showed almost 93% joint efficiency with the view-point of ultimate tensile strength and relatively low ductility than the base metal (BM). The local tensile deformation characteristic of the FSW joints was also examined using the digital image correlation (DIC) methodology by mapping the global and local strain distribution, and was subsequently analyzed by mechanics calculation. It is found that the tensile deformation of the FSW joints is highly heterogeneous, leading to a significant decrease in global ductility. The HAZ of the joints is the weakest region where the strain localizes early, and this localization extends until fracture with a strain near 30%, while the strain in the SZ and BM is only 1% and 4%, respectively. Local constitutive properties in different heterogeneous regions through the friction-stir-welded joint was also briefly evaluated by assuming iso-stress conditions. The local stress-strain curves of individual weld zones provide a clear indication of the heterogeneity of the local mechanical properties.

  19. Evaluation of intra-articular injection of autologous platelet lysate (PL) in horses with osteoarthritis of the distal interphalangeal joint.

    Science.gov (United States)

    Tyrnenopoulou, Panagiota; Diakakis, Nikolaos; Karayannopoulou, Maria; Savvas, Ioannis; Koliakos, Georgios

    2016-06-01

    Regenerative medicine has become one of the most promising therapies of equine osteoarthritis. Platelet lysate (PL) is rich in bioactive proteins and growth factors that play a crucial role in tissue healing. To evaluate the efficacy of intra-articularly injected autologous PL in equine athletes with naturally occurring osteoarthritis. Fifteen warmblood geldings aged 8-19 years with osteoarthritis of the distal interphalangeal joint were included in this study. They were randomly divided into two groups; 10 horses received intra-articular injections of PL and 5 of normal saline (controls). Before treatment, platelet-derived growth factor (PDGF) levels in basal plasma and prepared PL were estimated. Each joint was injected twice within a three-week period. Lameness was evaluated using the American Association of Equine Practitioners grading system, before treatment and 10 days after each intra-articular injection. Horses were examined fortnightly for one year. Radiographic examination was performed six months post-treatment. The generalized estimating equation test was used for statistical analysis. Acceptable levels of PDGF were detected in PLs (mean ± SD: 258.0 ± 52.3 pg/ml). The majority of horses (9/10) responded positively to PL treatment presenting lower lameness grades (p < 0.0005) compared to controls 10 days after the second injection, and returned to normal athletic activity. Radiographs revealed no changes in osteoarthritis lesions six months after treatment. One year post-injections, however, all horses relapsed to their initial degree of lameness. Intra-articularly injected autologous PL is an efficient method for temporarily managing osteoarthritis of the distal interphalangeal joint in athletic horses.

  20. Value of tomosynthesis for lesion evaluation of small joints in osteoarthritic hands using the OARSI score.

    Science.gov (United States)

    Martini, K; Becker, A S; Guggenberger, R; Andreisek, G; Frauenfelder, T

    2016-07-01

    To determine the diagnostic performance of tomosynthesis in depicting osteoarthritic lesions in comparison to conventional radiographs, with use of computed tomography (CT) as standard-of-reference. Imaging of 12 cadaveric hands was performed with tomosynthesis in dorso-palmar (dp) projection, conventional radiographs (dp) and multi-detector CT. Distal interphalangeal joint (DIP)II, DIPIII, proximal interphalangeal joint (PIP)II, PIPIII, first carpometacarpal (CMC) and scaphotrapezotrapezoidal joint (STT) were graded by two independent readers using the Osteoarthritis Research Society International (OARSI) score. The mean score for each feature was calculated for all modalities. Additional wrists were evaluated for presence of calcium pyrophosphate disease (CPPD). CT served as reference-standard. Inter-reader agreement (ICC) was calculated. Comparing tomosynthesis and conventional radiographs to CT, the sensitivity for the presence of osteophytes was 95,7% vs 65,2%; for joint space narrowing 95,8% vs 52,1%; for subchondral sclerosis 61,5% vs 51,3%; for lateral deformity 83.3% vs 83,3%; and for subchondral cysts 45,8% vs 29,2%. Erosions were not present. While tomosynthesis showed no significant difference in OARSI score grading to CT (mean OARSI-score CT: 16.8, SD = 10.6; mean OARSI-score Tomosynthesis: 16.3, SD = 9.6; P = 0.84), conventional radiographs had significant lower mean OARSI scores (mean OARSI-score X-ray: 11.1, SD = 8.3; P = 0.04). Inter-reader agreement for OARSI scoring was excellent (ICC = 0.99). CPPD calcifications present in CT, were also visible with tomosynthesis, but not with conventional radiography. In conclusion, tomosynthesis depicts more osteoarthritic changes in the small joints of the hand than conventional radiography using the OARSI scoring system and CT as the standard of reference. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  1. Fatigue damage evaluation method for the longitudinal welded joint of a FBR main vessel in the vicinity of the sodium surface

    International Nuclear Information System (INIS)

    Tanigawa, Masayuki; Shimokoshi, Minoru; Negishi, Hitoshi; Nagata, Takashi

    1990-01-01

    Metallurgical discontinuities are dominant in the fatigue strength reductions at the welded joints of vessels whose surfaces could be finished. In the welded joints of SUS 304 with TYPE 308 weld metal fatigue strength reductions are caused by strain concentrations as the result of the softening of the weld metal. A combination model of two elastic fully plastic materials is applicable to the structures under thermal stresses where displacements are self-controlled. Metallurgical discontinuities are represented by the difference of the yield strength. The longitudinal welded joint of a large FBR main vessel in the vicinity of the sodium surface was analyzed using this model under various conditions related to the design. Strain concentrations at the welded joint could be evaluated using the elastic follow-up model. The maximum value of the elastic follow-up parameter was 3.0 if the yield stress ratio of the weld metal to the base metal was not less than 0.8. (author)

  2. Compressive Strength Evaluation in Brazed ZrO2/Ti6Al4V Joints Using Finite Element Analysis

    Science.gov (United States)

    Sharma, Ashutosh; Kee, Se Ho; Jung, Flora; Heo, Yongku; Jung, Jae Pil

    2016-05-01

    This study aims to synthesize and evaluate the compressive strength of the ZrO2/Ti-6Al-4V joint brazed using an active metal filler Ag-Cu-Sn-Ti, and its application to dental implants assuring its reliability to resist the compressive failure in the actual oral environment. The brazing was performed at a temperature of 750 °C for 30 min in a vacuum furnace under 5 × 10-6 Torr atmosphere. The microstructure of the brazed joint showed the presence of an Ag-rich matrix and a Cu-rich phase, and Cu-Ti intermetallic compounds were observed along the Ti-6Al-4V bonded interface. The compressive strength of the brazed ZrO2/Ti-6Al-4V joint was measured by EN ISO 14801 standard test method. The measured compressive strength of the joint was ~1477 MPa—a value almost five times that of existing dental cements. Finite element analysis also confirmed the high von Mises stress values. The compressive strains in the samples were found concentrated near the Ti-6Al-4V position, matching with the position of the real fractured sample. These results suggest extremely significant compressive strength in ZrO2/Ti-6Al-4V joints using the Ag-Cu-Sn-Ti filler. It is believed that a highly reliable dental implant can be processed and designed using the results of this study.

  3. MRI and arthrography in the evaluation of TMJ disorders

    International Nuclear Information System (INIS)

    Nakasato, Tatsuhiko; Ehara, Shigeru; Tamakawa, Yoshiharu; Kobayakawa, Takafumi.

    1991-01-01

    Arthrosis of the temporomandibular joint (TMJ) is a noninfectious, noninflammatory condition characterized by joint pain, noise (clicking) and abnormal motion. It contains various disease processes, such as abnormalities in the menisci or masticating muscles, subluxation of the condyle and degenerative joint disease. Analysis of the morphology and dynamics of TMJ by means of imaging modalities has become highly advanced since the development of arthrography in the late 1970s. Magnetic resonance imaging (MRI) has become the modality of choice in the evaluation of TMJ owing to the development of surface coils. We retrospectively studied MRI and inferior joint compartment arthrography in the evaluation of TMJ disorders. Nineteen joints of 14 patients included 15 with internal derangement, two with osteoarthrosis and two normal joints. Sagittal MR images were routinely obtained in a resting position and in positions with the mouth half open, and also with the mouth fully open on balanced images. Although perforation of the menisci was difficult to evaluate, MRI and arthrography were equally useful in identifying the shape and position of the meniscus. However, MRI was more reliable in depicting TMJ abnormalities than arthrography. MRI is considered to be the modality of choice in screening arthrosis of TMJ, making the definitive diagnosis of internal derangement and monitoring conservative therapy for arthrosis. (author)

  4. MRI and arthrography in the evaluation of TMJ disorders

    Energy Technology Data Exchange (ETDEWEB)

    Nakasato, Tatsuhiko; Ehara, Shigeru; Tamakawa, Yoshiharu (Iwate Medical Univ., Morioka (Japan). School of Medicine); Kobayakawa, Takafumi

    1991-08-01

    Arthrosis of the temporomandibular joint (TMJ) is a noninfectious, noninflammatory condition characterized by joint pain, noise (clicking) and abnormal motion. It contains various disease processes, such as abnormalities in the menisci or masticating muscles, subluxation of the condyle and degenerative joint disease. Analysis of the morphology and dynamics of TMJ by means of imaging modalities has become highly advanced since the development of arthrography in the late 1970s. Magnetic resonance imaging (MRI) has become the modality of choice in the evaluation of TMJ owing to the development of surface coils. We retrospectively studied MRI and inferior joint compartment arthrography in the evaluation of TMJ disorders. Nineteen joints of 14 patients included 15 with internal derangement, two with osteoarthrosis and two normal joints. Sagittal MR images were routinely obtained in a resting position and in positions with the mouth half open, and also with the mouth fully open on balanced images. Although perforation of the menisci was difficult to evaluate, MRI and arthrography were equally useful in identifying the shape and position of the meniscus. However, MRI was more reliable in depicting TMJ abnormalities than arthrography. MRI is considered to be the modality of choice in screening arthrosis of TMJ, making the definitive diagnosis of internal derangement and monitoring conservative therapy for arthrosis. (author).

  5. Temperature and Humidity Profiles in the TqJoint Data Group of AIRS Version 6 Product for the Climate Model Evaluation

    Science.gov (United States)

    Ding, Feng; Fang, Fan; Hearty, Thomas J.; Theobald, Michael; Vollmer, Bruce; Lynnes, Christopher

    2014-01-01

    The Atmospheric Infrared Sounder (AIRS) mission is entering its 13th year of global observations of the atmospheric state, including temperature and humidity profiles, outgoing long-wave radiation, cloud properties, and trace gases. Thus AIRS data have been widely used, among other things, for short-term climate research and observational component for model evaluation. One instance is the fifth phase of the Coupled Model Intercomparison Project (CMIP5) which uses AIRS version 5 data in the climate model evaluation. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) is the home of processing, archiving, and distribution services for data from the AIRS mission. The GES DISC, in collaboration with the AIRS Project, released data from the version 6 algorithm in early 2013. The new algorithm represents a significant improvement over previous versions in terms of greater stability, yield, and quality of products. The ongoing Earth System Grid for next generation climate model research project, a collaborative effort of GES DISC and NASA JPL, will bring temperature and humidity profiles from AIRS version 6. The AIRS version 6 product adds a new "TqJoint" data group, which contains data for a common set of observations across water vapor and temperature at all atmospheric levels and is suitable for climate process studies. How different may the monthly temperature and humidity profiles in "TqJoint" group be from the "Standard" group where temperature and water vapor are not always valid at the same time? This study aims to answer the question by comprehensively comparing the temperature and humidity profiles from the "TqJoint" group and the "Standard" group. The comparison includes mean differences at different levels globally and over land and ocean. We are also working on examining the sampling differences between the "TqJoint" and "Standard" group using MERRA data.

  6. Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging

    International Nuclear Information System (INIS)

    Ouzounian, T.J.; Thompson, L.; Grogan, T.J.; Webber, M.M.; Amstutz, H.C.

    1987-01-01

    The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletal sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement

  7. Competencies Used to Evaluate High School Coaches.

    Science.gov (United States)

    Gratto, John

    1983-01-01

    Studies of how to evaluate high school coaches' effectiveness found that most respondents felt that principals, athletic directors, and coaches should jointly arrive at a method of evaluation. Coaching competencies rated most highly included prevention and care of athletic injuries, supervision, and consistent discipline. Other valued competencies…

  8. MR diagnosis of temporomandibular joint. A study of joint effusion

    International Nuclear Information System (INIS)

    Kaneda, Takashi; Yamashiro, Mitsuaki; Ozawa, Kaoru; Suzuki, Hiromi; Okada, Hiroyuki; Yamamoto, Hirotsugu

    1998-01-01

    The purposes of this study were to evaluate the relationship between correlation of MR joint effusion of the temporomandibular joint and disk position, to evaluate the relationship between joint effusion and aging, and to assess the frequency of MR joint effusion of bilateral temporomandibular joints. The temporomandibular joints of 192 patients with clinical symptoms of temporomandibular joint disorders were imaged bilaterally using high field, surface-coil MR imaging. Oblique sagittal and coronal proton density-weighted and T2-weighted images were obtained. Imaging findings of joint effusion were correlated with disk position, aging, and bilateral temporomandibular joints. MR showed effusion in 4% of the joints with normal superior disk position, 36% of the joints with disk displacement with reduction, and 45% of the joints with disk displacement without reduction. There were significant differences in the incidence of joint effusion between normal disk position and anterior disk displacement with or without reduction. Younger patients less than 40 years were significant higher the incidence of joint effusion than those of older patients. A significant association was seen between joint effusion and aging. MR showed effusion in 17% of the unilateral temporomandibular joint, 24% of the bilateral temporomandibular joints. There was no significant difference between unilateral and bilateral case. These results indicated that joint effusion using MR imaging was associated with varied temporomandibular joint pathologic states. (author)

  9. Joint resistance measurements of pancake and terminal joints for JT-60SA EF coils

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Murakami, Haruyuki; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2013-11-15

    Highlights: • To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted with a joint sample. • The joint sample was composed of pancake and terminal joints. • The measurements demonstrated that both joints fulfilled the design requirement. • Considering the measurements, the characteristics of both joints were investigated using an analytical model that represents the joints. -- Abstract: To evaluate the joint fabrication technology for the JT-60SA EF coils, joint resistance measurements were conducted using a sample consisting of pancake and terminal joints. Both joints are shake-hands lap joints composed of cable-in-conduit conductors and a pure copper saddle-shaped spacer. The measurements demonstrated that both joints fulfilled the design requirement. Considering these measurements, the characteristics of both joints were investigated using analytical models that represent the joints. The analyses indicated that the characteristics of the conductors used in the joints affect the characteristics of the joints.

  10. An evaluation of the spring finger solder joints on SA1358-10 and SA2052-4 connector assemblies (MC3617,W87)

    International Nuclear Information System (INIS)

    Kilgo, Alice C.; Vianco, Paul Thomas; Hlava, Paul Frank; Zender, Gary L.

    2006-01-01

    The SA1358-10 and SA2052-4 circular JT Type plug connectors are used on a number of nuclear weapons and Joint Test Assembly (JTA) systems. Prototype units were evaluated for the following specific defects associated with the 95Sn-5Sb (Sn-Sb, wt.%) solder joint used to attach the beryllium-copper (BeCu) spring fingers to the aluminum (Al) connector shell: (1) extended cracking within the fillet; (2) remelting of the solder joint during the follow-on, soldering step that attached the EMR adapter ring to the connector shell (and/or soldering the EMR shell to the adapter ring) that used the lower melting temperature 63Sn-37Pb (Sn-Pb) alloy; and (3) spalling of the Cd (Cr) layer overplating layer from the fillet surface. Several pedigrees of connectors were evaluated, which represented older fielded units as well as those assemblies that were recently constructed at Kansas City Plant. The solder joints were evaluated that were in place on connectors made with the current soldering process as well as an alternative induction soldering process for attaching the EMR adapter ring to the shell. Very similar observations were made, which crossed the different pedigrees of parts and processes. The extent of cracking in the top side fillets varied between the different connector samples and likely the EMR adapter ring to the shell. Very similar observations were made, which crossed the different pedigrees of parts and processes. The extent of cracking in the top side fillets varied between the different connector samples and likely reflected the different extents to which the connector was mated to its counterpart assembly. In all cases, the spring finger solder joints on the SA1358-10 connectors were remelted as a result of the subsequent EMR adapter ring attachment process. Spalling of the Cd (Cr) overplating layer was also observed for these connectors, which was a consequence of the remelting activity. On the other hand, the SA2052-4 connector did not exhibit evidence of

  11. Stress radiographs in the evaluation of degenerative femorotibial joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Tallroth, K.; Lindholm, T.S.

    1987-11-01

    Thirty-eight osteoarthrotic knees were examined to assess the widths of the femorotibial joint spaces. Radiographs were exposed with the patient lying, in a standing position, and with an adduction and abduction force. Forced compression of the osteoarthrotic joint compartment caused, on average, 18% greater narrowing than when loading it in the standing position. Compared to the joint space at rest, the non-weight-bearing compartment widened by 16% in the standing position and narrowed by 20% when stress was applied. Furthermore, the results showed an increase in laxity proportional to the degree of arthrosis. Stress radiographs significantly display the real cartilage width of both joint compartments. Knowledge of the condition of the articular cartilage in the non-weight-bearing compartment is important when considering a transfer of loading stresses by means of osteotomy. (orig.)

  12. Stress radiographs in the evaluation of degenerative femorotibial joint disease

    International Nuclear Information System (INIS)

    Tallroth, K.; Lindholm, T.S.

    1987-01-01

    Thirty-eight osteoarthrotic knees were examined to assess the widths of the femorotibial joint spaces. Radiographs were exposed with the patient lying, in a standing position, and with an adduction and abduction force. Forced compression of the osteoarthrotic joint compartment caused, on average, 18% greater narrowing than when loading it in the standing position. Compared to the joint space at rest, the non-weight-bearing compartment widened by 16% in the standing position and narrowed by 20% when stress was applied. Furthermore, the results showed an increase in laxity proportional to the degree of arthrosis. Stress radiographs significantly display the real cartilage width of both joint compartments. Knowledge of the condition of the articular cartilage in the non-weight-bearing compartment is important when considering a transfer of loading stresses by means of osteotomy. (orig.)

  13. The Challenges of Data Quality Evaluation in a Joint Data Warehouse.

    Science.gov (United States)

    Bae, Charles J; Griffith, Sandra; Fan, Youran; Dunphy, Cheryl; Thompson, Nicolas; Urchek, John; Parchman, Alandra; Katzan, Irene L

    2015-01-01

    The use of clinically derived data from electronic health records (EHRs) and other electronic clinical systems can greatly facilitate clinical research as well as operational and quality initiatives. One approach for making these data available is to incorporate data from different sources into a joint data warehouse. When using such a data warehouse, it is important to understand the quality of the data. The primary objective of this study was to determine the completeness and concordance of common types of clinical data available in the Knowledge Program (KP) joint data warehouse, which contains feeds from several electronic systems including the EHR. A manual review was performed of specific data elements for 250 patients from an EHR, and these were compared with corresponding elements in the KP data warehouse. Completeness and concordance were calculated for five categories of data including demographics, vital signs, laboratory results, diagnoses, and medications. In general, data elements for demographics, vital signs, diagnoses, and laboratory results were present in more cases in the source EHR compared to the KP. When data elements were available in both sources, there was a high concordance. In contrast, the KP data warehouse documented a higher prevalence of deaths and medications compared to the EHR. Several factors contributed to the discrepancies between data in the KP and the EHR-including the start date and frequency of data feeds updates into the KP, inability to transfer data located in nonstructured formats (e.g., free text or scanned documents), as well as incomplete and missing data variables in the source EHR. When evaluating the quality of a data warehouse with multiple data sources, assessing completeness and concordance between data set and source data may be better than designating one to be a gold standard. This will allow the user to optimize the method and timing of data transfer in order to capture data with better accuracy.

  14. Evaluating the Effectiveness Of Postfire Rehabilitation Treatments

    Science.gov (United States)

    Peter R. Robichaud; Jan L. Beyers; Daniel G. Neary

    2000-01-01

    Spending on postfire emergency watershed rehabilitation has increased during the past decade. A west-wide evaluation of USDA Forest Service burned area emergency rehabilitation (BAER) treatment effectiveness was undertaken as a joint project by USDA Forest Service Research and National Forest System staffs. This evaluation covers 470 fires and 321 BAER projects, from...

  15. Evaluation of local deformation behavior accompanying fatigue damage in F82H welded joint specimens by using digital image correlation

    International Nuclear Information System (INIS)

    Nakata, Toshiya; Tanigawa, Hiroyasu

    2012-01-01

    Highlights: ► In tensile, the TIG welded joint material was concentrated in the THAZ. ► In tensile, fracture occurred at the point where the axial strain converged. ► In fatigue, fracture occurred at the point where the Max. shear strain converged. ► Many macrocracks and cavities formed in the FGHAZ and THAZ of the cross section. - Abstract: By using digital image correlation, the deformation behaviors of local domains of F82H joint specimens welded using tungsten inert gas (TIG) and electron beam (EB) welding were evaluated during tensile and fatigue testing. In the tensile test specimens, the tensile strength decreased in the TIG-welded joints, and ductility decreased in both the EB- and TIG-welded joints. Because axial strain increased in the tempered heat-affected zone (HAZ) and led to the fracture of the TIG-welded joint, the strength was considered to have decreased because of welding. In fatigue testing, the number of cycles to fracture for the welded joint decreased to less than 40–60% of that for the base metal. For both fracture specimens, the largest value of shear strain was observed in the region approximately between the fine-grained HAZ and tempered HAZ; this shear strain ultimately led to fracture. Cavities and macrocracks were observed in the fine-grained HAZ and tempered HAZ in the cross sections of the fracture specimens, and geometrical damage possibly resulted in the reduction of fatigue lifetime.

  16. A preliminary case series evaluating the safety and immediate to short-term clinical benefits of joint mobilization in hemophilic arthritis of the lower limb.

    Science.gov (United States)

    Scaddan, Emma; Rowell, John; O'Leary, Shaun

    2017-09-01

    Arthritis resulting from recurrent intra-articular bleeding in individuals with hemophilia can be severely debilitating due to joint pain and stiffness with subsequent loss of mobility and function. Very limited studies have investigated the potential benefits of joint mobilization for this condition. This case series is a preliminary investigation of safety, as well as immediate and short-term clinical benefits, associated with gentle knee and ankle joint mobilization in people with hemophilic arthropathy. A single intervention of joint mobilization was applied to the affected knees and/or ankles of 16 individuals with severe or moderate hemophilia within a public hospital setting. Adverse events, as well as immediate (pain-free passive joint range, Timed Up and Go Test with maximum pain numerical rating scale) and short-term (Lower Extremity Functional Scale) effects of the intervention were evaluated with a repeated measures ANOVA. There were no adverse events. An immediate significant increase was observed in pain-free passive ankle joint range of motion ( p  < 0.05) following the joint mobilization intervention. The findings of this case series suggest that gentle joint mobilization techniques may be safely considered as part of a multimodal management approach for hemophilic arthropathy.

  17. Kinematic evaluation of movement smoothness in golf: relationship between the normalized jerk cost of body joints and the clubhead.

    Science.gov (United States)

    Choi, Ahnryul; Joo, Su-Bin; Oh, Euichaul; Mun, Joung Hwan

    2014-02-26

    When the human body is introduced to a new motion or movement, it learns the placement of different body parts, sequential muscle control, and coordination between muscles to achieve necessary positions, and it hones this new skill over time and repetition. Previous studies have demonstrated definite differences in the smoothness of body movements with different levels of training, i.e., amateurs compared with professionals. Therefore, we tested the hypothesis that skilled golfers swing a driver with a smoother motion than do unskilled golfers. In addition, the relationship between the smoothness of body joints and that of the clubhead was evaluated to provide further insight into the mechanism of smooth golf swing. Two subject groups (skilled and unskilled) participated in the experiment. The skilled group comprised 20 male professional golfers registered with the Korea Professional Golf Association, and the unskilled group comprised 19 amateur golfers who enjoy golf as a hobby. Six infrared cameras (VICON460 system) were used to record the 3D trajectories of markers attached to the clubhead and body segments, and the resulting data was evaluated with kinematic analysis. A physical quantity called jerk was calculated to investigate differences in smoothness during downswing between the two study groups. The hypothesis that skilled golfers swing a driver with a smoother motion than do unskilled golfers was supported. The normalized jerk of the clubhead of skilled golfers was lower than that of unskilled golfers in the anterior/posterior, medial/lateral, and proximal/distal directions. Most human joints, especially in the lower body, had statistically significant lower normalized jerk values in the skilled group. In addition, the normalized jerk of the skilled group's lower body joints had a distinct positive correlation with the normalized jerk of the clubhead with r = 0.657 (p golf swings and, eventually, to improve golf performance.

  18. Acousto-ultrasonic evaluation of adhesively bonded CFRP-aluminum joints

    International Nuclear Information System (INIS)

    Lee, Seung Hwan; Kwon, Oh Yang

    1997-01-01

    Correlation between the amount of artificial defects in bonded region and the acousto-ultrasonic parameters(AUPs) including signal amplitude and then the static strength of adhesively bonded joints of carbon fiber reinforced plastic(CFRP) laminates and Al6061 plates has been investigated. The effect of the frequency content and the bandwidth of input signals were studied using 200 kHz, 650 kHz, 1 MHz, 2 MHz pulses and 1 MHz tone-burst signals. With increasing fraction of defects, the signal amplitude and AUP1 were decreased whereas AUP2 was increased. This result has been attributed to the energy transfer characteristics of bonded joints with delamination-type defects and the change of spectral content due to the defects. Considering the nature of high attenuation, a pulse signal with major frequency content at the third harmonic of thickness mode resonance, 650 kHz for the dimension of specimens used in this study, has been found optimal for acousto-ultrasonic testing of CFRP-aluminum joints.

  19. Temporomandibular joint space in children without joint disease

    International Nuclear Information System (INIS)

    Larheim, T.A.

    1981-01-01

    Bilateral assessment of the temporomandibular joint space in children without joint disease is reported. Twenty-eight children were examined with conventional radiography and 23 with tomography. High prevalence of asymmetric joint spaces with both techniques indicated that great care should be taken when using narrowing or widening of the joint space as a diagnostic criterion in children with juvenile rheumatoid arthritis. Other signs, such as restricted translation of the mandibular head, and clinical symptoms should be evaluated. (Auth.)

  20. Joint Essential Tasks and a Framework for Evaluation

    National Research Council Canada - National Science Library

    Kingston, Gina; Johns, Kevin

    2002-01-01

    ...) to support the planning and evaluation of exercises. This process has been very successful and has seen ASJETs incorporated into the planning for the next major Australian-led exercise -- Crocodile 03...

  1. Sonographic evaluation of acute osteomyelitis in infants

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Kim, Yoo Kyung

    2002-01-01

    To analyze the related sonographic findings and to determine the value of sonography in establishing the diagnosis of acute osteomyelitis in infants. The sonographic findings of eleven infants aged 10 days-4 months (mean, 45 days) with acute osteomyelitis were retrospectively evaluated. The involved bones were the femur (n=5), humerus (n=2), tibia (n=2), rib(n=1), sternum (n=1), and calcaneus (n=1). Discontinuity or destruction of cortical margins, echotexture of the metaphysis and epiphysis, the presence of subperiosteal hypoechoic lesion, adjacent soft tissue swelling, distension of the joint capsule, the echotexture of joint effusion, and dislocation or subluxation of the involved joint were evaluated. The sonographic findings were compared with the plain radiographic (n=12) and MR (n=5) findings, with special attention to the identification of the metaphyseal or epiphyseal bony lesions and the involvement of adjacent joints. The sonographic findings of osteomyelitis were cortical discontinuity or destruction (n=12), hypoechoic lesions with an echogenic rim in the metaphysis (n=12), subperiosteal hypoechoic lesions (n=8), soft tissue swelling (n=9), a distended hip joint, with echogenic fluid (n=5), ill-demarcated echogenic lesions in the capital femoral epiphysis (n=5), and a subluxated hip joint (n=3). Plain radiographs revealed well or ill-defined osteolytic lesions in the metaphysis, accompanied by cortical destruction (n=8), new periosteal bone formation (n=3) and reactive sclerosis (n=2). Abnormality of the femoral epiphyses and joint involvement were not detected on plain radiographs, and in four cases no abnormality was noted. MR imaging showed that at T1WI, affected bony lesions were of low signal intensity and enhaned, with high signal intensity at T2WI. In all cases, both metaphyseal and epiphyseal lesions were demonstrated at MRI, but in one of the three cases in which an epiphyseal lesion was seen at MRI, this was not detected at US. Sonography is

  2. Sonographic evaluation of acute osteomyelitis in infants

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Lee, Sun Wha; Kim, Yoo Kyung [College of Medicine, Ewha Womans Univ., Seoul (Korea, Republic of)

    2002-03-01

    To analyze the related sonographic findings and to determine the value of sonography in establishing the diagnosis of acute osteomyelitis in infants. The sonographic findings of eleven infants aged 10 days-4 months (mean, 45 days) with acute osteomyelitis were retrospectively evaluated. The involved bones were the femur (n=5), humerus (n=2), tibia (n=2), rib(n=1), sternum (n=1), and calcaneus (n=1). Discontinuity or destruction of cortical margins, echotexture of the metaphysis and epiphysis, the presence of subperiosteal hypoechoic lesion, adjacent soft tissue swelling, distension of the joint capsule, the echotexture of joint effusion, and dislocation or subluxation of the involved joint were evaluated. The sonographic findings were compared with the plain radiographic (n=12) and MR (n=5) findings, with special attention to the identification of the metaphyseal or epiphyseal bony lesions and the involvement of adjacent joints. The sonographic findings of osteomyelitis were cortical discontinuity or destruction (n=12), hypoechoic lesions with an echogenic rim in the metaphysis (n=12), subperiosteal hypoechoic lesions (n=8), soft tissue swelling (n=9), a distended hip joint, with echogenic fluid (n=5), ill-demarcated echogenic lesions in the capital femoral epiphysis (n=5), and a subluxated hip joint (n=3). Plain radiographs revealed well or ill-defined osteolytic lesions in the metaphysis, accompanied by cortical destruction (n=8), new periosteal bone formation (n=3) and reactive sclerosis (n=2). Abnormality of the femoral epiphyses and joint involvement were not detected on plain radiographs, and in four cases no abnormality was noted. MR imaging showed that at T1WI, affected bony lesions were of low signal intensity and enhaned, with high signal intensity at T2WI. In all cases, both metaphyseal and epiphyseal lesions were demonstrated at MRI, but in one of the three cases in which an epiphyseal lesion was seen at MRI, this was not detected at US. Sonography is

  3. International co-operation in nuclear data evaluation

    International Nuclear Information System (INIS)

    Nordborg, C.

    2003-01-01

    The NEA Working Party on International Nuclear Data Evaluation Co-operation serves as a forum for the exchange of information on required improvements to evaluated nuclear data libraries used in all nuclear application areas. The main objective is to identify the major discrepancies in existing evaluated data libraries and to resolve these discrepancies in specifically established expert groups. The long-term goal is to have converging evaluated data libraries. This co-operative effort is very successful. It has resolved a number of outstanding nuclear data problems and has issued 15 reports in support of the studies undertaken jointly. (author)

  4. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture treatment for full-thickness cartilage defect models in rabbit knee joints: correlations with histological findings

    International Nuclear Information System (INIS)

    Tao, Hongyue; Feng, Xiaoyuan; Chen, Shuang; Li, Hong; Hua, Yinghui; Chen, Zhongqing

    2015-01-01

    To evaluate repair tissue (RT) after microfracture treatment for full-thickness cartilage defect models using quantitative MRI and investigate the correlations between MRI and histological findings. The animal experiment was approved by the Animal Care and Use Committee of our college. Thirty-six full-thickness cartilage defect models in rabbit knee joints were assigned to the microfracture or joint debridement group (as control). Each group consisted of 3-week, 5-week, and 7-week subgroups. MR imaging, including a three-dimensional double-echo steady-state sequence (3D-DESS), and T2 mapping were performed at 3, 5, and 7 weeks postoperatively. The thickness and T2 indices of RT were calculated. After MRI scans at each time point, operation sites were removed to make hematoxylin-eosin (H and E)-stained sections. Histological results were evaluated using the modified O'Driscoll score system. Comparisons were made between the two groups with respect to the MRI and histological findings, and correlation analysis was performed within each group. The thickness index and histological O'Driscoll score of RT in the two groups increased over time, while the T2 index decreased. The thickness index and histological O'Driscoll score of the microfracture group were higher than in the joint debridement group at each time point. The T2 index of the microfracture group was lower than in the joint debridement group at 3 weeks (P = 0.006), while it was higher than in the joint debridement group at 5 and 7 weeks (P = 0.025 and 0.025). The thickness index was positively correlated with the histological O'Driscoll score in both groups (microfracture: r s = 0.745, P s = 0.680, P = 0.002). The T2 index was negatively correlated with the histological O'Driscoll score in both groups (microfracture: r s = -0.715, P = 0.002; joint debridement: r s = -0.826, P < 0.001). Significant improvement over time after microfracture can be expected on the basis of the quantitative MRI finding and

  5. 18F-NaF PET/CT for the evaluation of temporomandibular joint disorder.

    Science.gov (United States)

    Suh, M S; Park, S H; Kim, Y-K; Yun, P-Y; Lee, W W

    2018-04-01

    To investigate the usefulness of a quantitative parameter (maximum standardised uptake value [SUVmax]) of 18 F-sodium fluoride (NaF) positron-emission tomography (PET)/computed tomography (CT) for the evaluation of temporomandibular joint (TMJ) disorder (TMD). Seventy-six TMD patients (male: female=14:62, age=40.3±17.1 years, bilateral: unilateral=40:36) with 152 TMJs were enrolled. The 18 F-NaF PET/CT parameter (SUVmax) was compared with the presence of TMJ arthralgia (arthralgic=86, non-arthralgic=66) and clinical subtypes based on the Research Diagnostic Criteria for TMD Axis I (TMD osteoarthritis=49, non-TMD osteoarthritis=67, and asymptomatic TMJ=36). Splint therapy was applied to 48 patients for 6 months without considering 18 F-NaF PET/CT findings. Post-splint therapy 18 F-NaF PET/CT was performed in 32 patients and clinical responses to the therapy were classified into improvement (n=33), no change (n=10), or aggravation (n=7) for 50 TMJs excluding asymptomatic TMJs (n=14). SUVmax was significantly greater in arthralgic TMJs than in non-arthralgic TMJs (6.62±3.56 versus 4.32±1.53, pchange in SUVmax was observed in improved (from 6.16±2.68 to 6.09±2.60, p=0.4915) and unchanged (from 6.46±4.19 to 6.77±4.32, p=0.3223) TMJs. 18 F-NaF PET/CT is a useful imaging tool for TMD evaluation because SUVmax showed a fair diagnostic performance for arthralgic TMJ and TMD osteoarthritis, and a correlation with the therapeutic response. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Evaluation of aural manifestations in temporo-mandibular joint dysfunction.

    Science.gov (United States)

    Sobhy, O A; Koutb, A R; Abdel-Baki, F A; Ali, T M; El Raffa, I Z; Khater, A H

    2004-08-01

    Thirty patients with temporo-mandibular joint dysfunction were selected to investigate the changes in otoacoustic emissions before and after conservative treatment of their temporo-mandibular joints. Pure tone audiometry, transient-evoked otoacoustic emissions (TEOAE), distortion-product otoacoustic emissions (DPOAE) as well as a tinnitus questionnaire were administered to all patients before and after therapy. Therapy was conservative in the form of counselling, physiotherapy, anti-inflammatory agents, muscle relaxants, and occlusal splints. Results indicated insignificant changes in the TEOAEs, whereas there were significant increases in distortion product levels at most of the frequency bands. These results were paralleled to subjective improvement of tinnitus.

  7. Quantitative magnetic resonance imaging (MRI) evaluation of cartilage repair after microfracture treatment for full-thickness cartilage defect models in rabbit knee joints: correlations with histological findings

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Hongyue; Feng, Xiaoyuan; Chen, Shuang [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Li, Hong; Hua, Yinghui [Fudan University, Department of Sports Medicine, Huashan Hospital, Shanghai (China); Chen, Zhongqing [Fudan University, Department of Pathology, Huashan Hospital, Shanghai (China)

    2014-11-26

    To evaluate repair tissue (RT) after microfracture treatment for full-thickness cartilage defect models using quantitative MRI and investigate the correlations between MRI and histological findings. The animal experiment was approved by the Animal Care and Use Committee of our college. Thirty-six full-thickness cartilage defect models in rabbit knee joints were assigned to the microfracture or joint debridement group (as control). Each group consisted of 3-week, 5-week, and 7-week subgroups. MR imaging, including a three-dimensional double-echo steady-state sequence (3D-DESS), and T2 mapping were performed at 3, 5, and 7 weeks postoperatively. The thickness and T2 indices of RT were calculated. After MRI scans at each time point, operation sites were removed to make hematoxylin-eosin (H and E)-stained sections. Histological results were evaluated using the modified O'Driscoll score system. Comparisons were made between the two groups with respect to the MRI and histological findings, and correlation analysis was performed within each group. The thickness index and histological O'Driscoll score of RT in the two groups increased over time, while the T2 index decreased. The thickness index and histological O'Driscoll score of the microfracture group were higher than in the joint debridement group at each time point. The T2 index of the microfracture group was lower than in the joint debridement group at 3 weeks (P = 0.006), while it was higher than in the joint debridement group at 5 and 7 weeks (P = 0.025 and 0.025). The thickness index was positively correlated with the histological O'Driscoll score in both groups (microfracture: r{sub s} = 0.745, P < 0.001; joint debridement: r{sub s} = 0.680, P = 0.002). The T2 index was negatively correlated with the histological O'Driscoll score in both groups (microfracture: r{sub s} = -0.715, P = 0.002; joint debridement: r{sub s} = -0.826, P < 0.001). Significant improvement over time after

  8. Cooperative joint precoding in a downlink cellular system with shared relay: Design and performance evaluation

    KAUST Repository

    Kwon, JaeWoo; Park, Kihong; Ko, Youngchai; Yang, Hongchuan

    2012-01-01

    In this paper, we investigate a relay enhanced cellular system, where a relay station is located in the overlap area served by two base stations. We propose cooperative joint precoding schemes for the downlink transmission of such relay enhanced cellular system to maximize the system capacity while minimizing the interference at both the relay station and the mobile stations. We formulate the optimization problems to maximize the system capacity and design the multiuser precoding vectors at each base station and the relay station. We quantify the ergodic rate performance of the proposed multiuser precoding schemes through statistical analysis. The extensively derived ergodic expressions will facilitate the accurate performance evaluation of the proposed transmission schemes. Numerical results show that the proposed schemes can effectively cancel the interference and improve the sum rate and the outage performance for cell edge users. © 2002-2012 IEEE.

  9. Cooperative joint precoding in a downlink cellular system with shared relay: Design and performance evaluation

    KAUST Repository

    Kwon, JaeWoo

    2012-10-01

    In this paper, we investigate a relay enhanced cellular system, where a relay station is located in the overlap area served by two base stations. We propose cooperative joint precoding schemes for the downlink transmission of such relay enhanced cellular system to maximize the system capacity while minimizing the interference at both the relay station and the mobile stations. We formulate the optimization problems to maximize the system capacity and design the multiuser precoding vectors at each base station and the relay station. We quantify the ergodic rate performance of the proposed multiuser precoding schemes through statistical analysis. The extensively derived ergodic expressions will facilitate the accurate performance evaluation of the proposed transmission schemes. Numerical results show that the proposed schemes can effectively cancel the interference and improve the sum rate and the outage performance for cell edge users. © 2002-2012 IEEE.

  10. STUDY, EVALUATION AND TEST OF SUBMODULE TO GIRDER BOLTED JOINT

    CERN Document Server

    Blocki, J; Miralles, Ll; Topilin, N D

    2000-01-01

    The object of the present work is to study the bolted joint submodule to girder. This joint is critical from the point of view of the mechanical integrity of the Tilecal Barrel and Extended Barrel modules and LAr Endcaps. Theoretical analysis, FEM calculations and tests have been carried out in order to find a solution that fulfils the safety factors design criteria.

  11. Biomechanical Analysis and Evaluation Technology Using Human Multi-Body Dynamic Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Hyuk; Shin, June Ho; Khurelbaatar, Tsolmonbaatar [Kyung Hee University, Yongin (Korea, Republic of)

    2011-10-15

    This paper presents the biomechanical analysis and evaluation technology of musculoskeletal system by multi-body human dynamic model and 3-D motion capture data. First, medical image based geometric model and material properties of tissue were used to develop the human dynamic model and 3-D motion capture data based motion analysis techniques were develop to quantify the in-vivo joint kinematics, joint moment, joint force, and muscle force. Walking and push-up motion was investigated using the developed model. The present model and technologies would be useful to apply the biomechanical analysis and evaluation of human activities.

  12. Teacher ambivalence towards school evaluation : promoting and ruining teacher professionalism

    OpenAIRE

    Hult, Agneta; Edström, Charlotta

    2016-01-01

    Today’s evaluation society makes teachers participate in a stream of external evaluations. How teachers experience evaluation in school and how this affects their work and professionalism is the focus of this article. Teachers’ views of external and internal evaluations and of the consequences for school practice are described and analysed. The interviewed teachers emphasised the importance of internal evaluations performed close to daily teaching practice and jointly with students and collea...

  13. Solar Alpha Rotary Joint (SARJ) Lubrication Interval Test and Evaluation (LITE). Post-Test Grease Analysis

    Science.gov (United States)

    Golden, Johnny L.; Martinez, James E.; Devivar, Rodrigo V.

    2015-01-01

    The Solar Alpha Rotary Joint (SARJ) is a mechanism of the International Space Station (ISS) that orients the solar power generating arrays toward the sun as the ISS orbits our planet. The orientation with the sun must be maintained to fully charge the ISS batteries and maintain all the other ISS electrical systems operating properly. In 2007, just a few months after full deployment, the starboard SARJ developed anomalies that warranted a full investigation including ISS Extravehicular Activity (EVA). The EVA uncovered unexpected debris that was due to degradation of a nitride layer on the SARJ bearing race. ISS personnel identified the failure root-cause and applied an aerospace grease to lubricate the area associated with the anomaly. The corrective action allowed the starboard SARJ to continue operating within the specified engineering parameters. The SARJ LITE (Lubrication Interval Test and Evaluation) program was initiated by NASA, Lockheed Martin, and Boeing to simulate the operation of the ISS SARJ for an extended time. The hardware was designed to test and evaluate the exact material components used aboard the ISS SARJ, but in a controlled area where engineers could continuously monitor the performance. After running the SARJ LITE test for an equivalent of 36+ years of continuous use, the test was opened to evaluate the metallography and lubrication. We have sampled the SARJ LITE rollers and plate to fully assess the grease used for lubrication. Chemical and thermal analysis of these samples has generated information that has allowed us to assess the location, migration, and current condition of the grease. The collective information will be key toward understanding and circumventing any performance deviations involving the ISS SARJ in the years to come.

  14. Clinical significance of dynamic magnetic resonance imaging in the evaluation of wrist joint in Rheumatoid arthritis

    International Nuclear Information System (INIS)

    Shim, Yong Woon; Suh, Jin Suck; Lee, Soo Kon; Lee, Ji Soo; Cho, Jae Hyun

    1996-01-01

    To assess the role of contrast-enhanced dynamic Magnetic Resonance Imaging in evaluation disease activity of rheumatoid arthritis. Forty-seven wrist joints with rheumatoid arthritis were examined prospectively. Coronal images of the wrist were obtained using fat-suppression Fast multi-planar spoiled gradient recalled (FMPSPGR) acquisition in the steady state ; TR/TE 102/6.4 msec, flip angle = 60, 4 slices per sequence, FOV = 8 cm, matrix 256 X 192 at 1.5 Tesla. Scans were carried out once before and five to eight times after an intravenous Gd-DPTA injection, at 30-second-intervals. The enhancement of synovium were measured, the enhancement ratio was calculated(postcontrast SNR/precontrast SNR) and time-enhancement ratio curves were plotted. Patients were divided into three groups according to the ratio of initial to peak enhancement : less than 30% ; 30-80% more than 80%. Differences among the three groups were statistically tested using clinical indices and laboratory data as variable. Comparing one group with another, there were no significant differences in clinical indices and laboratory data except for the parameter of grip strength. Enhancement pattern measured in a single wrist joint was not comparable to a clinical index in predicting disease activity in rheumatoid arthritis

  15. Significance of clinical evaluation of the metacarpophalangeal joint in relation to synovial/bone pathology in rheumatoid and psoriatic arthritis detected by magnetic resonance imaging.

    Science.gov (United States)

    Stone, Millicent A; White, Lawrence M; Gladman, Dafna D; Inman, Robert D; Chaya, Sam; Lax, Matthew; Salonen, David; Weber, Deborah A; Guthrie, Judy A; Pomeroy, Emma; Podbielski, Dominik; Keystone, Edward C

    2009-12-01

    Rheumatologists base many clinical decisions regarding the management of inflammatory joint diseases on joint counts performed at clinic. We investigated the reliability and accuracy of physically examining the metacarpophalangeal (MCP) joints to detect inflammatory synovitis using magnetic resonance imaging (MRI) as the gold standard. MCP joints 2 to 5 in both hands of 5 patients with rheumatoid arthritis (RA) and 5 with psoriatic arthritis (PsA) were assessed by 5 independent examiners for joint-line swelling (visually and by palpation); joint-line tenderness by palpation (tender joint count, TJC) and stress pain; and by MRI (1.5 Tesla superconducting magnet). Interrater reliability was assessed using kappa statistics, and agreement between examination and corresponding MRI assessment was assessed by Fisher's exact tests (p 0.8) and positive predictive value (= 0.8). For PsA, significant associations exist between TJC and MRI synovitis scores (p < 0.01) and stress pain and MRI edema scores (p < 0.04). Assessment of swelling by palpation was not significantly associated with synovitis or edema as determined by MRI in RA or PsA (p = 0.54-1.0). In inflammatory arthritis, disease activity in MCP joints can be reliably assessed at the bedside by examining for joint-line tenderness (TJC) and visual inspection for swelling. Clinical assessment may have to be complemented by other methods for evaluating disease activity in the joint, such as MRI, particularly in patients with PsA.

  16. Push-off tests and strength evaluation of joints combining shrink fitting with bonding

    Science.gov (United States)

    Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi

    1997-03-01

    Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.

  17. Evaluation of cold crack susceptibility on HSLA steel welded joints

    Directory of Open Access Journals (Sweden)

    Silverio-Freire Júnior, R. C.

    2003-04-01

    Full Text Available The present study addresses an evaluation of the effect of several welding parameters on cold cracking formation in welded joints of High Strength and Low Alloy steels, as well as the resulting microstructures and hardness values. The main parameters studied include the variation of the preheating temperature, drying time of the electrode, chemical composition and thickness of the base metal. The presence of cold cracking in the joints was analyzed from Tekken tests using steel plates made of SAR 80 T, 100 T and 120 T with of various thickness. The plates were welded by Shielded Metal Arc Welding either with or without pre-heating. Different preheating temperatures were studied, i.e., 375, 455 and 525 K. AWS E 12018 G and 11018 G electrodes were used under different conditions, i.e., not dried or dried up to 2, 3 and 4 h at 515 K. The results indicated the presence of cracks in the welded metals with the combination of hardness values above 230 HV and the formation of high contents of acicular ferrite (above 93 % in the welds without preheating. Higher crack susceptibility was also observed in the thick welded metal plates.

    Este trabajo evalúa la influencia de la variación de temperatura de precalentamiento, del tiempo de secado del electrodo, de la composición química y del espesor del metal base sobre la formación de fisuras en frío, inducidas por el hidrógeno en juntas soldadas de aceros de alta resistencia y baja aleación y su relación con la microestructura y dureza resultante. Para esto, se analizó la presencia de fisuras en frío en probetas para ensayos Tekken, fabricadas a partir de chapas de aceros SAR 80 T, 100 T y 120 T, con diferentes espesores y soldados por proceso de arco eléctrico con electrodo revestido, sin precalentamiento y con precalentamiento, a 375, 455 y 525 K, empleando electrodos AWS E 12018 G y 11018 G no secados y secados durante 2, 3 y 4 h. Los resultados obtenidos indicaron la presencia de fisuras

  18. Evaluation of extraarticular consequences of Temporomandibular joint disorders

    Directory of Open Access Journals (Sweden)

    Sh. Jafari

    1994-07-01

    Full Text Available Temporo Mandibular Joint disorders are the most important ethiologic factor for chronic orofacial pain and have a relatively new place in scientific researches and clinical studies in dentistry. Since dentists can play an important role in diagnosis and treatment of these disorders, routine dental examination should include functional examination of osteomatognatic apparatus.

  19. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    Science.gov (United States)

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  20. Source terms and releases in routine and accidental situations: the scheme implemented at the Joint Research Centre in Ispra for the evaluation of the dose to the population

    International Nuclear Information System (INIS)

    D'Alberti, F.

    2004-01-01

    This paper presents the scheme and the tools implemented for the evaluation of the dose to the population due to the routine and emergency situations of the nuclear installations at the Joint Research Centre in Ispra. In particular, it will be introduced and discussed the use of models provided by commercial software and international technical recommendations. The approach for all the calculations required the usual conservative hypotheses, so that the maximum dose results have been derived. The dose evaluations have been performed retrospectively, for the years 1990-2002. The doses are evaluated net of the doses due to the naturally occurring radioactivity. (author)

  1. Fracture probability evaluation of a LWR pressure vessel

    International Nuclear Information System (INIS)

    Grandemange, J.; Pellissier-Tanon, A.; Quero, J.; Carnino, A.; Dufresne, J.

    1978-01-01

    Fracture probability evaluation, of a LWR pressure vessel have been performed in the past, using statistical data from conventional plant. A more accurate evaluation has been requested in 1976 from the SCSIN to the CEA. With this object, a joint collaboration agreement has been signed between CEA, EURATOM/ISPRA and FRAMATOME. The whole program proceeding from this agreement is managed by a joint board including the three partners. The basic objective of this program is to develop a method which integrates, or makes it possible to integrate at a later stage, the greatest number of significant parameters. Also, in order to prepare the practical applications, a special effort is being made to collect the data corresponding to these parameters. Parallel basic research program have been launched in order to clarify our knowledge on some important parts of the main factors contributing to the evaluation. The results of this research will be progressively introduced into the method or will help checking its validity

  2. Effect of joint design on ballistic performance of quenched and tempered steel welded joints

    International Nuclear Information System (INIS)

    Balakrishnan, M.; Balasubramanian, V.; Madhusudhan Reddy, G.

    2014-01-01

    Highlights: • Traditional usage of austenitic stainless steel filler for armour steel welding shows poor ballistic performance. • Earlier efforts show dubious success on ballistic resistance of armour steel joints. • Comparative evaluation of equal/unequal joint design on ballistic performance. • Effect of joint design covers the main aspects of successful bullet stoppage. - Abstract: A study was carried out to evaluate the effect of joint design on ballistic performance of armour grade quenched and tempered steel welded joints. Equal double Vee and unequal double Vee joint configuration were considered in this study. Targets were fabricated using 4 mm thick tungsten carbide hardfaced middle layer; above and below which austenitic stainless steel layers were deposited on both sides of the hardfaced interlayer in both joint configurations. Shielded metal arc welding process was used to deposit for all layers. The fabricated targets were evaluated for its ballistic performance and the results were compared in terms of depth of penetration on weld metal. From the ballistic test results, it was observed that both the targets successfully stopped the bullet penetration at weld center line. Of the two targets, the target made with unequal double Vee joint configuration offered maximum resistance to the bullet penetration at weld metal location without any bulge at the rear side. The higher volume of austenitic stainless steel front layer and the presence of hardfaced interlayer after some depth of soft austenitic stainless steel front layer is the primary reason for the superior ballistic performance of this joint

  3. JPEG XS call for proposals subjective evaluations

    Science.gov (United States)

    McNally, David; Bruylants, Tim; Willème, Alexandre; Ebrahimi, Touradj; Schelkens, Peter; Macq, Benoit

    2017-09-01

    In March 2016 the Joint Photographic Experts Group (JPEG), formally known as ISO/IEC SC29 WG1, issued a call for proposals soliciting compression technologies for a low-latency, lightweight and visually transparent video compression scheme. Within the JPEG family of standards, this scheme was denominated JPEG XS. The subjective evaluation of visually lossless compressed video sequences at high resolutions and bit depths poses particular challenges. This paper describes the adopted procedures, the subjective evaluation setup, the evaluation process and summarizes the obtained results which were achieved in the context of the JPEG XS standardization process.

  4. Federal/State cooperation in the licensing of a nuclear power project. A joint licensing process between the US Nuclear Regulatory Commission and the Washington State Energy Facility Site Evaluation Council

    International Nuclear Information System (INIS)

    1984-05-01

    This report summarizes and documents a joint environmental review and licensing process established between the US Nuclear Regulatory Commission (NRC) and the Washington State Energy Facility Site Evaluation Council (EFSEC) in 1980-1983 for the Skagit/Hanford Nuclear Project (S/HNP). It documents the agreements made between the agencies to prepare a joint environmental impact statement responsive to the requirements of the National Environmental Policy Act of 1969 (NEPA) and the Washington State Environmental Policy Act. These agreements also established protocol to conduct joint public evidentiary hearings on matters of mutual jurisdiction, thereby reducing the duplication of effort and increasing the efficiency of the use of resources of federal and state governments and other entities involved in the process. This report may provide guidance and rationale to licensing bodies that may wish to adopt some of the procedures discussed in the report in the event that they become involved in the licensing of a nuclear power plant project. The history of the S/HNP and of the agreement processes are discussed. Discussions are provided on implementing the joint review process. A separate section is included which presents independent evaluations of the process by the applicant, NRC, and EFSEC

  5. The evaluation of extracorporeal shockwave therapy in naturally occurring osteoarthritis of the stifle joint in dogs.

    Science.gov (United States)

    Dahlberg, J; Fitch, G; Evans, R B; McClure, S R; Conzemius, M

    2005-01-01

    Extracorporeal shockwave therapy (ESWT) has expanded from the original uses of human urinary calculi treatment to veterinary orthopaedic applications. This paper investigates the feasibility and efficacy of treating dogs with osteoarthritis of the stifle joint with ESWT. In this study, dogs with persistent stifle lameness despite previous surgical or medical treatment were either treated with ESWT or served as untreated controls. The more lame rear limb of each dog was determined by force platform analysis. The range of motion (ROM) of the stifle joints was assessed by goniometry. Force platform gait analysis and goniometry were performed on both groups for four visits at three-week intervals and a final examination four weeks later. Shock wave therapy was performed three times on the treated dogs, once at each of the first three examinations. A placebo treatment consisting of clipping and wetting the hair was performed on the control dogs. The vertical forces were evaluated for objective analysis of treatment response. For peak vertical force (PVF), four of seven treated dogs improved, while only one of five of control dogs improved. The PVF for the within group analysis did not show any significant change for the treated group, however, the control group has a significant decrease (p = 0.05) in PVF consistent with an increase in lameness. The range of motion (ROM) of the stifle joint improved in five of seven treated dogs and three of five controls. Dogs in the treated group had a trend toward increased ROM (p = 0.07) and a 'positive slope' when compared to dogs in the control group which did not have a significant change (p = 0.78) and had a negative slope indicating the dogs were developing a decrease in ROM. The subjective data provided by client questionnaire did not show significant difference between groups.

  6. MR imaging evaluation of diabetic foot

    International Nuclear Information System (INIS)

    Beltran, J.; Campanini, D.S.; McCalla, M.; Knight, C.T.

    1988-01-01

    Fourteen diabetic patients with suspected foot infection and/or neuropathic joint were evaluated with MR imaging to identify the presence and extent of infection and also to exclude coexistent infection in the neuropathic joint. Osteomyelitis (n = 8), abscess (n = 7), septic arthritis (n = 4), tenosynovitis (n = 4), and neuropathic joint (n = 5) were diagnosed with MR imaging. Osteomyelitis and/or abscess were excluded by MR findings in 13 instances. Most patients with infection had one more than one site of involvement. Clinical or surgical confirmation of the MR diagnoses was obtained in all but nine of the infection sites or cases of neuropathic joint. Only one false-negative diagnosis of osteomyelitis was made in this series. It is concluded that MR imaging provided accurate information regarding the presence and extent of infection and that this information was decisive in patient management

  7. MRI evaluation of osteonecrosis in knee joints after intravenous administration of corticosteroids in patients with severe acute respiratory syndrome

    International Nuclear Information System (INIS)

    Gao Yong'an; Liu Hualiang; Dong Yanqing; Liu Ying; Li Kuncheng; Wang Zhongwei; Li Ping

    2005-01-01

    Objective: To evaluate MRI features of osteonecrosis in knee joints after intravenous administration of exogenous corticosteroids in patients with severe acute respiratory syndrome (SARS). Methods: MRI was done in 18 patients (medical staff from 4 hospitals) suffered from SARS and treated with intravenous use of exogenous corticosteroids in hip joints and knee joints to indicate the findings and characteristics of osteonecrosis as well as their relation with hormone amount. Results: Eleven patients showed lesions of osteonecrosis in knee joints with bilateral in 7 and unilateral in 4, and 3 patients were complicated with avascular necrosis in bilateral femoral heads. Among the 38 lesions in knee joints, 34 lesions were located in medial condylu, lateral condylus and shaft of femur, and 4 in medial condylus or lateral condylus of tibia. Large-middle lesions showed geographic focus of typically heterogeneous signal (low or intermediate signal intensity on T 1 WI and high or intermediate signal intensity T 2 WI) within the marrow that was surrounded by characteristic low signal intensity, serpentine border on T 1 , T 2 WI. This border showed a classic double-line sign on T 2 WI in 4 lesions. Small lesions showed low signal intensity on T 1 and low or high signal intensity on T 2 WI. Subchondral avascular necrosis in middle-upper femoral heads showed intermediate signal intensity on T 1 weighted images and high or complicated signal intensity on T 2 WI encircled with characteristic low signal intensity, serpentine border on T 1 and T 2 WI. This border showed a classic double-line sign on T 2 weighted images in avascular necrosis of bilateral femoral heads in 1 case. Conclusion: In these cases, osteonecrosis in knee joints was more than in femoral heads in patients with SARS after intravenous use of exogenous corticosteroids, mostly located in medial condylus, lateral condylus and shaft of femur as well as in medial condylus or lateral condylus of tibia. So, MRI should

  8. Dual joint space arthrography in temporomandibular joint disorders: Comparison with single inferior joint space arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Sik; Chang, Duk Soo; Lee, Kyung Soo; Kim, Woo Sun; Sung, Jung Ho; Jun, Young Hwan [Capital Armed Forces General Hospital, Seoul (Korea, Republic of)

    1989-02-15

    The temporomandibular joint(TMJ) is really a complex of two synovial space separated by fibrocartilaginous disc. Single inferior joint space arthrography is commonly performed for evaluation of TMJ disorders, which is known to be superior in demonstrating joint dynamics. But it reveals only the inferior surface of the disc. Therefore, dual space arthrography is superior to demonstrate the soft tissue anatomic feature of the joint such as disc position and shape. Authors performed 83 TMJ arthrograms in TMJ problems. Initially, the inferior joint space was done and then the superior space was sequentially contrasted. The follow results were noted: 1. In all cases, dual space arthrography revealed accurate disc shape and positions. 2. Concordant findings between the two techniques: 68 cases (82%). Discordance between the two techniques: 15 cases (18%) 3. Possible causes of discordance between inferior and dual space arthrography. a) Normal varians of anterior recess: 3 cases b) Posterior disc displacement: 4 cases c) Influence of the patient's head position change :4 cases d) False perforation: 2 cases e) Reduction change: 2 cases 4. In 5 cases with anterior displacement, dual space arthrography gave additional findings such as adhesion within the superior space, which could not be evaluated by single inferior space.

  9. Joint recovery programme versus usual care - An economic evaluation of a clinical pathway for joint replacement surgery

    NARCIS (Netherlands)

    Brunenberg, DE; van Steyn, MJ; Sluimer, JC; Bekebrede, LL; Bulstra, SK; Joore, MA

    2005-01-01

    Objective: The objective of the present study was to determine the incremental cost-effectiveness of a clinical pathway for patients undergoing joint replacement, the Joint Recovery Programme (JRP), as compared with usual care. The existing care process was revised to contain costs and shorten

  10. Performance Evaluation of Waterproofing Membrane Systems Subject to the Concrete Joint Load Behavior of Below-Grade Concrete Structures

    Directory of Open Access Journals (Sweden)

    Jaeyoung Song

    2017-11-01

    Full Text Available Below-grade structures such as parking lots, underground subway tunnels, and basements are growing in scale and reaching deeper below-ground levels. In this type of environment, they become subject to higher water pressure. The concrete material of the structures is exposed to wet conditions for longer periods of time, which makes the proper adhesion of waterproofing membranes difficult. Joint movements from increased structural settlement, thermal expansion/shrinkage, and physical loads from external sources (e.g., vehicles make securing durable waterproofing challenging. While ASTM Guides, Korean Codes, and BS Practice Codes on below-grade waterproofing stress the importance of manufacturer specification for quality control, ensuring high quality waterproofing for the ever-changing scale of construction remains a challenge. This study proposes a new evaluation method and criteria which allow for the selection of waterproofing membranes based on specific performance attributes and workmanship. It subjects six different waterproofing membrane systems (installed on dry and wet surface conditioned mortar slab specimens with an artificial joint to different cyclic movement widths to 300 cycles in water to demonstrate that inadequate material properties and workmanship are key causes for leakages.

  11. CT of the temporomandibular joint: The conservative approach

    International Nuclear Information System (INIS)

    Jend, H.H.; Jend-Rossmann, I.; Heller, M.

    1986-01-01

    Until recently, CT investigation of temporomandibular joint (TMJ) disorders has been regarded as a sophisticated procedure. A method of investigation was developed that allows easy evaluation of axial scans. The method was evaluated in a series of 65 joints with arthrographically diagnosed internal derangements. In anterior disk displacement CT findings led to an identical diagnosis in 56 of 65 joints (sensitivity, 86%). In clinically asymptomatic joints investigated for other reasons, only one of 12 showed signs of internal derangement on CT (specificity, 92%). This conservative approach to CT evaluation of internal derangement seems to be as accurate as more sophisticated methods. It is easy to perform, requires no additional manpower or computer time, and has a very good reproducibility

  12. Role of magnetic resonance imaging in the evaluation of articular cartilage in painful knee joint

    Directory of Open Access Journals (Sweden)

    Digish Shah

    2014-01-01

    Full Text Available Aim: The aim of this study was to determine the role of the magnetic resonance imaging (MRI in patients with atraumatic knee pain. Background and Objectives: Knee pain is one of the most common problems faced by people from time immemorial. There is a wide range of disease ranging from traumatic to degenerative causing knee pain in which articular cartilage is involved. Over the past 15 years, MRI has become the premier, first-line imaging study that should be performed in the evaluation of the painful knee in particular in tears of menisci, cruciate and collateral ligaments, osteochondral abnormalities (chondromalacia, osteoarthritis and osteochondral defects, synovial cysts and bone bruises. MRI, by virtue of its superior soft-tissue contrast, lack of ionizing radiation and multiplanar capabilities, is superior to more conventional techniques for the evaluation of articular cartilage. Materials and Methods: A prospective study was carried out on 150 patients in the Department of Radio-diagnosis, Padmashree Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pimpri, Pune over a period of 2 years from June 2011 to May 2013. Patients having fracture or dislocations of the knee joint were also excluded from the study. Detailed clinical history, physical and systemic examination findings of all patients were noted in addition to the laboratory investigations. All patients were subjected to radiograph of knee anterior-posterior and lateral view. MRI was performed with Siemens 1.5 Tesla MAGNETOM Avanto machine. Results: In our study of 150 patients with knee pain, articular cartilage defect was found in 90 patients (60%. Out of 90 patients with articular cartilage defect, 30 patients (20% had full thickness cartilage defects. Subchondral marrow edema was seen beneath 30 patients (20% with articular cartilage defects. 32 patients (21.1% had a complex or macerated meniscal tear. Complete anterior cruciate ligament tear was found in seven

  13. Evaluation of the nugget diameter in spot welded joints between two steel sheets by means of a potential drop technique

    International Nuclear Information System (INIS)

    Tohmyoh, Hironori; Ikarashi, Hidetomo; Matsui, Yoichi; Hasegawa, Yuta; Obara, Satoshi

    2015-01-01

    A potential drop technique which utilizes the electrical circuit used in resistance spot welding is reported. Spot welded samples comprising two steel sheets were inserted between the two Cu electrodes and a constant direct current was supplied between the electrodes. The potential drop between two points, one on each electrode, was determined by analysis for various values of nugget diameter and various values of the contact resistance between the Cu electrodes and the steel sheet sample. The nugget diameter of the spot welded joint could be quantitatively evaluated from the measured potential drop and the equation obtained from the analysis. (paper)

  14. Evaluation of the nugget diameter in spot welded joints between two steel sheets by means of a potential drop technique

    Science.gov (United States)

    Tohmyoh, Hironori; Ikarashi, Hidetomo; Matsui, Yoichi; Hasegawa, Yuta; Obara, Satoshi

    2015-08-01

    A potential drop technique which utilizes the electrical circuit used in resistance spot welding is reported. Spot welded samples comprising two steel sheets were inserted between the two Cu electrodes and a constant direct current was supplied between the electrodes. The potential drop between two points, one on each electrode, was determined by analysis for various values of nugget diameter and various values of the contact resistance between the Cu electrodes and the steel sheet sample. The nugget diameter of the spot welded joint could be quantitatively evaluated from the measured potential drop and the equation obtained from the analysis.

  15. Reliability of early radiographic evaluations for canine hip dysplasia obtained from the standard ventrodorsal radiographic projection

    International Nuclear Information System (INIS)

    Corley, E.A.; Keller, G.G.; Lattimer, J.C.; Ellersieck, M.R.

    1997-01-01

    To determine reliability of preliminary evaluations for canine hip dysplasia (CHD) performed by the Orthopedic Foundation for Animals on dogs between 3 and 18 months of age. Retrospective analysis of data from the Orthopedic Foundation for Animals database. 2,332 Golden Retrievers, Labrador Retrievers, German Shepherd Dogs, and Rottweilers for which preliminary evaluation had been performed between 3 and 18 months of age and for which results of a definitive evaluation performed after 24 months of age were available. Each radiograph was evaluated, and hip joint status was graded as excellent, good, fair, or borderline phenotype or mild, moderate, or severe dysplasia. Preliminary evaluations were performed by 1 radiologist; definitive evaluations were the consensus of 3 radiologists. Reliability of preliminary evaluations was calculated as the percentage of definitive evaluations (normal vs dysplastic) that were unchanged from preliminary evaluations. Reliability of a preliminary evaluation of normal hip joint phenotype decreased significantly as the preliminary evaluation changed from excellent (100%) to good (97.9%) to fair (76.9%) phenotype. Reliability of a preliminary evaluation of CHD increased significantly as the preliminary evaluation changed from mild (84.4%) to moderate (97.4%) CHD. Reliability of preliminary evaluations increased significantly as age at the time of preliminary evaluation increased, regardless of whether dogs received a preliminary evaluation of normal phenotype or CHD. Results suggest that preliminary evaluations of hip joint status in dogs are generally reliable. However, dogs that receive a preliminary evaluation of fair phenotype of mild CHD should be reevaluated after 24 months of age

  16. Methodology For Evaluation Of Regulatory Effectiveness In Physical Protection

    International Nuclear Information System (INIS)

    Izmaylov, Alexander; Valente, John; Griggs, James R.; Rexroth, Paul; Piskarev, Alexander; Babkin, Vladimir; Sokolov, Egor; Melton, Ronald B.; Cunningham, Mitchel E.; Baker, Kathryn A.; Brothers, Alan J.

    2005-01-01

    Material protection, control, and accounting (MPC and A) regulatory documents play an important role in securing and protecting nuclear material by regulating a variety of activities at different hierarchical levels. The development, implementation, and practical application of these regulatory documents requires a significant investment of financial and material resources. Therefore, it is important to evaluate the effectiveness of the regulatory development process and the extent to which regulations improve the effectiveness of MPC and A at nuclear sites. The joint Russian and U.S. Regulatory Development Project has a goal of evaluating the effectiveness of regulatory documents developed for MPC and A. As part of this joint Project, a methodology for evaluating effectiveness has been developed. This methodology was developed around physical protection objectives. The developed methodology specifies physical protection objectives to be accomplished through the implementation of a regulatory system based on the physical protection goals at the nuclear sites. It includes approaches to assessing regulatory effectiveness, the hierarchical structure of physical protection objectives to be accomplished through implementing regulations, a 'mapping' of the physical protection objectives to the regulatory framework, a list of criteria for evaluating the effectiveness of physical protection regulations and effectiveness indicators, as well as means and methods for gathering information and implementation of this evaluation.

  17. Evaluation of osseous changes of TMJ in internal derangement and osteoarthritis patients using MRI

    International Nuclear Information System (INIS)

    Cho, Su Beom; Koh, Kwang Joon

    2001-01-01

    To evaluate the osseous changes of TMJ in internal derangement and osteoarthritis patients using MRI. MR images of 111 TMJs in 64 patients were analyzed to evaluate the osseous changes. 111 TMJs were divided into 6 groups according to the radiologic Stages by Schellhas and Wilkes. On MR images, we evaluate the osseous changes of articular eminence and condylar head. The most frequent Stage in internal derangement of TMJ was Stage Ι. And 38 joints (25.2%) revealed osteoarthritis with internal derangement. When osseous change of articular eminence and condylar head occur, flattening was the most common osseous change. Sclerosis was observed in all Stages and osteophytosis of condylar head was observed in Stage ΙΙ (1.8%) and ΙΙΙ (0.9%). Out of 28 joints with osteoarthritis, 6 joints (21.4%) showed joint effusion. MR image revealed abnormal configuration of disk, but the detection of minimal osseous change was subtle

  18. Cyclic and Explosive Evaluation of New Proposed Steel Joint

    Directory of Open Access Journals (Sweden)

    Iman Faridmehr

    2016-01-01

    Full Text Available The behaviour of a novel steel beam-to-column connection, the saddlebag, subjected to cyclic and progressive collapse, was evaluated in this paper. The cyclic behaviour considered the interstory drift angle and flexural strength in accordance with 2010 AISC Seismic Provisions, while progressive collapse assessment was evaluated through the plastic hinge rotation angle based on acceptance criteria provided in the UFC 4-023-03 guideline. From the cyclic test, one complete cycle of an interstory drift angle of 0.06 rad was satisfied for the saddlebag connection, which is an indication of the effectiveness in accordance with 2010 AISC Seismic Provisions. Besides, the new proposed connection developed adequate catenary action, which is a fundamental criterion to resist against progressive collapse. The resulting fuller hysteretic loops with large energy dissipation capacity in the proposed saddlebag connection guarantee its ability to address the inelastic deformation demands in earthquake conditions.

  19. Design and evaluation of a modular lower limb exoskeleton for rehabilitation.

    Science.gov (United States)

    Dos Santos, Wilian M; Nogueira, Samuel L; de Oliveira, Gustavo C; Pena, Guido G; Siqueira, Adriano A G

    2017-07-01

    This paper deals with the evaluation of an exoskeleton designed for assisting individuals to rehabilitate compromised lower limb movements resulting from stroke or incomplete spinal cord injury. The exoskeleton is composed of lightweight tubular structures and six free joints that provide a modular feature to the system. This feature allows the exoskeleton to be adapted to assist the movement of one or more patient joints. The actuation of the exoskeleton is also modular, and can be performed passively, by means of springs and dampers, or actively through actuators. In addition, its telescopic tubular links, developed to adjust the size of the links in order to align the joints of the exoskeleton with patient joints, allows the exoskeleton to be adjustable to fit different patients. Experiments considering the interaction between a healthy subject and the exoskeleton are performed to evaluate the influence of the exoskeleton structure on kinematic and muscular activity profiles during walking.

  20. Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.

    Science.gov (United States)

    Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao

    2015-11-01

    This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.

  1. ECOWindS Evaluation and Adaptation Report

    DEFF Research Database (Denmark)

    Piirainen, Kalle A.

    2014-01-01

    for evaluation and future adaptation of the Joint Action Plan” (JAP) (Deliverable no. 4.1), contributing to Task 4.4., “Revising the JAP”. The objective of this report is first to present a system for monitoring progress of the JAP in terms of the strategic objectives and provide guidelines for adapting the JAP...

  2. Evaluation of lesser metatarsophalangeal joint plantar plate tears with contrast-enhanced and fat-suppressed MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dinoa, Vanessa; Ranke, Felipe von; Costa, Flavia; Marchiori, Edson [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2016-05-15

    To present findings of plantar plate (PP) lesions from MRI with administration of gadolinium and to differentiate PP lesions from others causes of metatarsalgia. Two musculoskeletal radiologists reviewed 249 contrast-enhanced forefoot MRI scans from patients with metatarsalgia between June 2012 and June 2013. Evaluations focused on hyper-vascularized/fibrous tissue and other findings associated with PP tears. Fifty-nine patients had PP tears, 59 % were female. Most of these patients, 48/59 (81.4 %), had a single metatarsophalangeal (MTP) PP lesion in one foot, although 7/59 patients had one lesion in each foot, 3/59 (5.1 %) had two in one foot, and 1/59 (1.7 %) had three lesions in one foot. The second MTP joint was the most common location for PP tears (n = 56), followed by the third (n = 12) and fourth (n = 3) MTP joints. Lateral (n = 33) and full thickness (n = 28) PP lesions were the most frequent, and central (n = 3) and lateral/central (n = 7) tears were less prevalent. Fifty (70.5 %) PP lesions showed pericapsular fibrosis in pre-contrast sequences, and 21 (29.5 %) were visible only after administration of gadolinium. All PP lesions had collateral ligament involvement. Others findings included interosseous tendon lesions (n = 29), interosseous tendon rupture (n = 29), synovitis (n = 49), flexor tenosynovitis (n = 28), crossover toe (n = 2), hammertoe (n = 1), intermetatarsal space (IS) neuromas (n = 11), and third IS neuromas (n = 12). PP tears are a common cause of metatarsalgia, accounting for more than 20 % of cases in our sample. A substantial portion of the lesions (29.5 %) became visible only after the administration of gadolinium. (orig.)

  3. Evaluation of lesser metatarsophalangeal joint plantar plate tears with contrast-enhanced and fat-suppressed MRI

    International Nuclear Information System (INIS)

    Dinoa, Vanessa; Ranke, Felipe von; Costa, Flavia; Marchiori, Edson

    2016-01-01

    To present findings of plantar plate (PP) lesions from MRI with administration of gadolinium and to differentiate PP lesions from others causes of metatarsalgia. Two musculoskeletal radiologists reviewed 249 contrast-enhanced forefoot MRI scans from patients with metatarsalgia between June 2012 and June 2013. Evaluations focused on hyper-vascularized/fibrous tissue and other findings associated with PP tears. Fifty-nine patients had PP tears, 59 % were female. Most of these patients, 48/59 (81.4 %), had a single metatarsophalangeal (MTP) PP lesion in one foot, although 7/59 patients had one lesion in each foot, 3/59 (5.1 %) had two in one foot, and 1/59 (1.7 %) had three lesions in one foot. The second MTP joint was the most common location for PP tears (n = 56), followed by the third (n = 12) and fourth (n = 3) MTP joints. Lateral (n = 33) and full thickness (n = 28) PP lesions were the most frequent, and central (n = 3) and lateral/central (n = 7) tears were less prevalent. Fifty (70.5 %) PP lesions showed pericapsular fibrosis in pre-contrast sequences, and 21 (29.5 %) were visible only after administration of gadolinium. All PP lesions had collateral ligament involvement. Others findings included interosseous tendon lesions (n = 29), interosseous tendon rupture (n = 29), synovitis (n = 49), flexor tenosynovitis (n = 28), crossover toe (n = 2), hammertoe (n = 1), intermetatarsal space (IS) neuromas (n = 11), and third IS neuromas (n = 12). PP tears are a common cause of metatarsalgia, accounting for more than 20 % of cases in our sample. A substantial portion of the lesions (29.5 %) became visible only after the administration of gadolinium. (orig.)

  4. Radiographic evaluation of coxofemoral joint laxity in dogs part II: Comparison of stress-radiographic positioning techniques in dogs with hip dysplasia

    International Nuclear Information System (INIS)

    Duangdaun Kaenkangploo; Phiwipha Kamonrat; Marissak Kalpravidh

    2002-01-01

    Two stress-radiographic positioning techniques for evaluation of coxofemoral joint laxity in dogs with hip dysplasia were compared with the standard technique. Forty, healthy, large breed dogs were divided into two groups of 20 dogs. Group 1 had normal hips. Group 2 were dogs with mild to moderated grade of hip dysplasia according to the Orthopedic Foundation for Animals (OFA) standard. Dogs were anesthetized and placed in dorsal recumbency before 3 radiographic techniques, standard hip-extended, 60 deg and 90 deg stress techniques, were taken. For the 60 deg stress technique, hind legs were extended in parallel to each other at 60 deg to the table top and femoral heads were manually pushed craniodorsally during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. Subluxation index (SI) and dorsolateral subluxation score (DLS score) of coxofemoral joints were assessed from radiographs. The SI of normal dogs from standard, 60 deg and 90 deg stress techniques were 0.15, 0.20 and 0.23 and of dysplastic dogs were 0.34, 0.40 and 0.41 respectively. The degress of subluxation assessed from the two stress technique radiographs were significantly greater (p0.05) than those shown on the standard technique radiographs in both groups of dogs. DLS scores of normal dogs from standard, 60 deg and 90 deg stress techniques were 65.1, 64.3 and 61.0 percent and of dysplastic dogs were 55.4, 53.6 and 47.6 percent respectively. Mean of DLS scores assessed from the 90 deg radiographs was significantly lower (p0.05) than those assessed from radiographs of other two teachniques in both groups of dogs. The findings suggested that the 90 deg stress technique is more efficient than the standard and 60 deg stress techniques for radiographic evaluation of coxofemoral joint laxity in dogs with mild hip dysplasia and early

  5. High-cycle fatigue properties of small-bore socket-welded pipe joint

    International Nuclear Information System (INIS)

    Maekawa, Akira; Noda, Michiyasu; Suzuki, Michiaki

    2009-01-01

    Piping and equipment in nuclear power plants are structures including many welded joints. Reliability of welded joints is one of high-priority issues to improve the safety of nuclear power plants. However, occurrence of fatigue failures in small-bore socket-welded pipe joints by high-cycle vibrations is still reported. In this study, fatigue experiments on a socket-welded joint of austenitic stainless steel pipe was conducted under excitation conditions similar to those in actual plants to investigate vibration characteristics and fatigue strength. It was found that the natural frequency of pipe with socket-welded joint gradually decreased as fatigue damage developed, according to the Miner rule for fatigue life evaluation. The results indicate that the fatigue life of the welded pipe joint could be estimated by monitoring the decreasing ratio of the natural frequency of the pipe. The evaluation of decreasing ratio of the natural frequency in addition to fatigue damage evaluation by the Miner rule could enhance the accuracy of fatigue life evaluation. (author)

  6. An Evaluation of a Clerkship In Cardiology

    Science.gov (United States)

    Edson, John N.; and others

    1969-01-01

    Evaluation of the clinical clerkship in Cardiology for general practitioners proves there is an urgent need for continuing post graduate medical education for general practitioners. Clerkship was offered jointly by the Long Island College Hospital and the State University of New York Downstate Medical Center, Brooklyn, New York. (IR)

  7. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction

    OpenAIRE

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-01-01

    Introduction: Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. Subjects and methods: In prospective study, we evalua...

  8. Evaluation of Spasticity Variations at the Elbow Joint of CVA Patients According to the Biomechanical Indices

    Directory of Open Access Journals (Sweden)

    Nima Soleimanzadeh-Ardabili

    2013-10-01

    Full Text Available Objective: The goal of the present study was to evaluate spasticity variations by increase the velocity of motion and MAS value in the elbow flexor and extensor muscles at extension and flexion of CVA patients elbow joint according to the biomechanical indices. Materials & Methods: Fifteen adult patients with a history of stroke and upper-extremity spasticity volunteered to participate in this study and fifteen healthy subjects were recruited in order to establish the control group. The degree of spasticity was evaluated for each patient using the MAS. CPM tests were imposed in elbow extension and flexion and the biomechanical indices were calculated at each of the following velocities: 15, 45, 75 and 120 º/s. Results: It seemed a regular increment of the viscoelastic and viscose stiffness indices by increasing the velocity of motion and the rate of MAS value in both extension and flexion in all test groups and also there was significant regular increment of elastic stiffness index by increasing the velocity in both extension and flexion between the control group and group 1 and also irregular increment between group1 and group 2 and 3 and also the effect of mentioned index was decreased at higher level of MAS. Conclusion: it seemed the more effect of elastic stiffness in spasticity in CVA patients at lower level of MAS and more effect of viscose stiffness in higher level of MAS and also results showed the increment of viscose stiffness by increment of speed of motion and the rate of MAS.

  9. A systematised MRI approach to evaluating the patellofemoral joint

    Energy Technology Data Exchange (ETDEWEB)

    Chhabra, Avneesh; Subhawong, Ty K.; Carrino, John A. [Johns Hopkins Hospital, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States)

    2011-04-15

    Knee pain in young patients is a common indication for knee MRI. Many static and dynamic internal derangements of the patellofemoral joint in these patients lead to various secondary MRI findings. This article focuses on how to systematically approach, detect, and emphasize the importance of these findings in the diagnosis of patellofemoral tracking and impingement syndromes with relevant case examples. (orig.)

  10. A systematised MRI approach to evaluating the patellofemoral joint

    International Nuclear Information System (INIS)

    Chhabra, Avneesh; Subhawong, Ty K.; Carrino, John A.

    2011-01-01

    Knee pain in young patients is a common indication for knee MRI. Many static and dynamic internal derangements of the patellofemoral joint in these patients lead to various secondary MRI findings. This article focuses on how to systematically approach, detect, and emphasize the importance of these findings in the diagnosis of patellofemoral tracking and impingement syndromes with relevant case examples. (orig.)

  11. Evaluation of certain contaminants in food.

    Science.gov (United States)

    2017-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various contaminants or groups of contaminants in food. The first part of the report contains a brief description of general considerations addressed at the meeting, including updates on matters of interest to the work of the Committee. A summary follows of the Committee’s evaluations of technical, toxicological and/or dietary exposure data for six contaminants or groups of contaminants (aflatoxins, 4,15-diacetoxyscirpenol, fumonisins, glycidyl esters, 3-MCPD esters and 3-MCPD, sterigmatocystin) as well as an evaluation of co-exposure of fumonisins with aflatoxins. Annexed to the report is a summary of the toxicological and dietary exposure information as well as the Committee’s recommendations on the contaminants and groups of contaminants considered at this meeting.

  12. Results of total joint arthroplasty and joint preserving surgery in younger patients evaluated by alternative outcome measures

    DEFF Research Database (Denmark)

    Klit, Jakob

    2014-01-01

    , hip OA is associated with FAI covering three fundamentally different hip deformities, including acetabular dysplasia; all hypothesized to initiates OA development. Where PAO is used worldwide as a joint-preserving procedure in acetabular dysplasia, TKA and THA are the treatment of choice of end stage......BACKGROUND: Knee and hip OA is the clinical and pathological outcome of a functional and structural failure of the joint, resulting in pain and physical dysfunction. Despite the similarity in clinical presentation the pathogenesis seems to differ. Where knee OA is associated with obesity and trauma...... information prior to PAO, TKA and THA surgery. MATERIAL AND METHODS: This PhD thesis is based on three studies. Study I is a cross-sectional survey of preserved hip joints with a mean follow-up of ten years after PAO. One hundred patients (121 PAO's) were eligible for inclusion. An inquiry to the National...

  13. Joint ventures: to pursue or not to pursue?

    Science.gov (United States)

    Blaszyk, Michael D; Hill-Mischel, Jody

    2007-11-01

    Hospitals should carefully select joint venture partners. The joint venture evaluation process should involve a high-level screen of strategic opportunities. Hospitals should develop a full business plan for the joint venture.

  14. Evaluation of Joint Performance on High Nitrogen Stainless Steel Which is Expected to Have Higher Allergy Resistance

    Science.gov (United States)

    Nakano, Kouichi

    Austenitic stainless steel, which includes nickel for stabilizing austenitic structure, is used for various purposes, for example, for structural material, corrosion-resistant material, biomaterial etc. Nickel is set as one of the rare metals and economizing on nickel as the natural resources is required. On the other hand, nickel is one of the metals that cause metallic allergy frequently. Therefore, high nitrogen stainless steel, where nitrogen stabilizes austenitic structure instead of nickel, has been developed in Japan and some of the foreign countries for the above reason. When high nitrogen stainless steel is fused and bonded, dissolved nitrogen is released to the atmospheric area, and some of the material properties will change. In this study, we bonded high nitrogen stainless steel by stud welding process, which is able to bond at short time, and we evaluate joint performance. We have got some interesting results from the other tests and examinations.

  15. Joint angle sensors for closed-loop control

    Science.gov (United States)

    Ko, Wen H.; Miao, Chih-Lei

    In order to substitute braces that have built-in goniometers and to provide feedback signals for closed loop control of lower extremity Functional Neuromuscular System in paraplegics, a stretchable capacitive sensor was developed to accurately detect angular movement in joints. Promising clinical evaluations on the knee joints of a paraplegic and a volunteer were done. The evaluations show great promise for the possibility of implantation applications.

  16. The diagnostic protocol for evaluation of periprosthetic joint infection

    Directory of Open Access Journals (Sweden)

    Alen Mlekuž

    2015-06-01

    Full Text Available Infection is becoming the most important as well as the most devastating mechanism of prosthetic joint failure. The incidence is increasing due to increased sensitivity of orthopedic surgeons for this diagnosis, better diagnostics, and  because the absolute number of operated patients is increasing and because more often very sick, debilitated, and immunocompromised patients are operated on. The trend shows the incidence to further increase in the years to come. The diagnosis may be very easy in case of high grade processes, but also extremely difficult in low grade infections. Misdiagnosing infection leads to repeat early failures and revisions that are distressing for patients as well as for surgeons. To avoid failures related to misdiagnosed prosthetic joint infections a step-wise algorithm of action is proposed and the diagnostic strength of the steps discussed. The key point is to select the potential candidates to define the possibility of an ongoing infection and then to select the tools to strengthen the suspicion. The further procedures base on the analysis of the pseudo-synovial fluid obtained by aspiration. The diagnostic conclusions form the basis for considered treatment decisions.

  17. Sensitivity and specificity of a new MRI method evaluating temporo-mandibular joint disc-condyle relationships: an in vivo study.

    Science.gov (United States)

    Benbelaïd, R; Fleiter, B

    2006-03-01

    The aim of this study was to evaluate sensitivity and specificity of a new method to locate temporo-mandibular joint (TMJ) disc using magnetic resonance imaging (MRI) and analyze disc-condyle relationships, in asymptomatic subjects and patients with disc displacement. Twenty-nine sagittal MRI of 16 subjects, 8 asymptomatic volunteers and 8 subjects with anterior disc displacement, were carried out during controlled opening from intercuspal position up to a 25 mm opening. Selected sections were analyzed with a graphic computerized system of coordinates. The total surface area (TS) of disc section was separated into anterior surface area (AS) and posterior surface area. Areas were determined by computer. Two trained examiners drew images at random. The reliability of AS/TS ratio index was evaluated in a previous study. AS/TS ratio sensitivity (Se) and specificity (Sp) were calculated closed mouth, 5 mm open and 25 mm open mouth. Best sensitivity (Se=0.63) and specificity (Sp=0.81) were obtained when MRI was realized with closed mouth and 25 mm open mouth. Lower sensitivity was observed when MRI was performed either with closed mouth (Se=0.54) or 25 mm open mouth (Se=0.18). Lower specificity was observed with 5 mm open mouth (Sp=0.68). In conclusion, it was confirmed as well that MRI of anterior disc displacement should be performed with closed mouth and opened mouth. Thus, further studies are required to assess disc displacement and mechanical alterations and to evaluate the risk of direct damage on TMJ tissues.

  18. Individual performance evaluation of the Brazilian Nuclear Energy Commission (CNEN): a meta-evaluative study

    International Nuclear Information System (INIS)

    Bezerra, Leonardo Ferreira

    2017-01-01

    The present study is a summative meta-evaluation that had as objective to evaluate the quality of the process of evaluation of individual performance of the servers of the National Commission of Nuclear Energy, being guided by the scientific curiosity to know to what extent the evaluation of performance the National Commission for Nuclear Energy meets the quality standards disseminated by the Joint Committee on Standards for Educational Evaluation. The methodology chosen to be used was based on the management approach and had as a guiding principle of the study the elaboration of a framework of criteria considering the aforementioned standards. The criteria established in the criteria framework guided the preparation of the items of the questionnaire sent to the National Commission of Nuclear Energy servers. In addition to the questionnaire, the observation of this author was considered in the context where the phenomenon occurred, which allowed a better reflective analysis of the data collected by the questionnaire. Regarding the results, it can be inferred that the performance evaluation developed at the National Commission of Nuclear Energy can be considered of quality, highlighting the servers' trust for the data, the communication process of the program stages, the credibility of the evaluators, the process of negotiation of goals and adaptability of the instrument over the course of the cycle. However, there are some opportunities for improvement, considering the relevance of evaluation as a tool to improve the performance of the autarchy's servers. Among the points that need to be improved is that there is currently a lack of knowledge about the legal basis and justification of the process of evaluation process by the servers and the lack of clarity regarding the content of the final evaluation report. Among the recommendations of this study, one can consider as the most relevant the need to: disseminate the results of this meta-evaluation to the

  19. Testing and evaluation of solidified high-level waste forms. Joint annual progress report 1983

    International Nuclear Information System (INIS)

    Malow, G.

    1985-01-01

    A second joint programme of the European Atomic Community was started in 1981 under the indirect action programme (1980-84), Action No 5 'Testing and evaluation of the properties of various potential materials for immobilizing high activity waste'. The overall objective of the research is to test various European potential solidified high-level radioactive waste forms so as to predict their behaviour after disposal. The most important aspect is to produce data to calculate the activity release from the waste products under the attack of various aqueous solutions. The experiments were partly performed under waste repository relevant conditions and partly under simplified conditions for investigating basic activity release mechanisms. The topics of the programme were: (i) studies of basic leaching mechanisms; (ii) studies of hydrothermal leaching and surface attack of waste glasses; (iii) leach test carried out in contact with granite at low water flow rates; (iv) static leach tests with specimen surrounded by canister and backfill materials; (v) specific isotope leach tests in slowly flowing water; (vi) leach test of actinide spiked samples; (vii) leach tests of highly radioactive samples; (viii) leach tests of alpha radiation stability; (ix) studies of mechanical stability; (x) studies of mineral phases as model compounds and phase relations

  20. Performance Evaluation of New Joint EDF-RM Scheduling Algorithm for Real Time Distributed System

    Directory of Open Access Journals (Sweden)

    Rashmi Sharma

    2014-01-01

    Full Text Available In Real Time System, the achievement of deadline is the main target of every scheduling algorithm. Earliest Deadline First (EDF, Rate Monotonic (RM, and least Laxity First are some renowned algorithms that work well in their own context. As we know, there is a very common problem Domino's effect in EDF that is generated due to overloading condition (EDF is not working well in overloading situation. Similarly, performance of RM is degraded in underloading condition. We can say that both algorithms are complements of each other. Deadline missing in both events happens because of their utilization bounding strategy. Therefore, in this paper we are proposing a new scheduling algorithm that carries through the drawback of both existing algorithms. Joint EDF-RM scheduling algorithm is implemented in global scheduler that permits task migration mechanism in between processors in the system. In order to check the improved behavior of proposed algorithm we perform simulation. Results are achieved and evaluated in terms of Success Ratio (SR, Average CPU Utilization (ECU, Failure Ratio (FR, and Maximum Tardiness parameters. In the end, the results are compared with the existing (EDF, RM, and D_R_EDF algorithms. It has been shown that the proposed algorithm performs better during overloading condition as well in underloading condition.

  1. Evaluation of Nuclear Hydrogen Production System

    International Nuclear Information System (INIS)

    Park, Won Seok; Park, C. K.; Park, J. K. and others

    2006-04-01

    The major objective of this work is tow-fold: one is to develop a methodology to determine the best VHTR types for the nuclear hydrogen demonstration project and the other is to evaluate the various hydrogen production methods in terms of the technical feasibility and the effectiveness for the optimization of the nuclear hydrogen system. Both top-tier requirements and design requirements have been defined for the nuclear hydrogen system. For the determination of the VHTR type, a comparative study on the reference reactors, PBR and PBR, was conducted. Based on the analytic hierarchy process (AHP) method, a systematic methodology has been developed to compare the two VHTR types. Another scheme to determine the minimum reactor power was developed as well. Regarding the hydrogen production methods, comparison indices were defined and they were applied to the IS (Iodine-Sulfur) scheme, Westinghouse process, and the, high-temperature electrolysis method. For the HTE, IS, and MMI cycle, the thermal efficiency of hydrogen production were systematically evaluated. For the IS cycle, an overall process was identified and the functionality of some key components was identified. The economy of the nuclear hydrogen was evaluated, relative to various primary energy including natural gas coal, grid-electricity, and renewable. For the international collaborations, two joint research centers were established: NH-JRC between Korea and China and NH-JDC between Korea and US. Currently, several joint researches are underway through the research centers

  2. Clinical and ultrasound evaluation of the response to tocilizumab treatment in patients with rheumatoid arthritis: a case series.

    Science.gov (United States)

    Epis, Oscar; Filippucci, Emilio; Delle Sedie, Andrea; De Matthaeis, Anna; Bruschi, Eleonora

    2014-05-01

    This case series evaluates the clinical and ultrasound response to tocilizumab treatment in patients with rheumatoid arthritis (RA). Six patients with active RA (DAS28 ≥ 3.2) for ≥6 months, refractory to conventional DMARDs or anti-TNF agents, received tocilizumab 8 mg/kg every 4 weeks, as monotherapy or in combination with DMARDs, for 6 months. The following clinical parameters were assessed monthly: number of tender joints (28 and 44 joints), number of swollen joints (28 and 44 joints), DAS28-ESR, DAS28-CRP, VAS score, global health status, health assessment questionnaire, patient global assessment of disease activity, physician global assessment of disease activity, functional assessment of chronic illness therapy (FACIT), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP). All patients also underwent a gray-scale ultrasonography (US) assessment with power Doppler evaluation at each visit. All clinical parameters improved during the study, versus baseline. This improvement was statistically significant for most parameters 2 months following tocilizumab initiation and was sustained to the end of the observation period. The number of tender joints (44-joint evaluation), the FACIT score, and ESR and CRP concentrations were significantly improved versus baseline values after the first month of tocilizumab treatment. The course of US evaluations mirrored that of clinical parameters; a faster and more evident response was observed for foot joints, with respect to hand joints. This case series suggested the rapid clinical benefit of tocilizumab. Ultrasound assessment showed that the onset of this effect was faster in the foot joints than in the hand joints.

  3. A quantitative method for evaluating inferior glenohumeral joint stiffness using ultrasonography.

    Science.gov (United States)

    Tsai, Wen-Wei; Lee, Ming-Yih; Yeh, Wen-Lin; Cheng, Shih-Chung; Soon, Kok-Soon; Lei, Kin Fong; Lin, Wen-Yen

    2013-02-01

    Subluxation of the affected shoulder in post-stroke patients is associated with nerve disorders and muscle fatigue. Clinicians must be able to accurately and reliably measure inferior glenohumeral subluxation in patients to provide appropriate treatment. However, quantitative methods for evaluating the laxity and stiffness of the glenohumeral joint (GHJ) are still being developed. The aim of this study was to develop a new protocol for evaluating the laxity and stiffness of the inferior GHJ using ultrasonography under optimal testing conditions and to investigate changes in the GHJ from a commercially available humerus brace and shoulder brace. Multistage inferior displacement forces were applied to create a glide between the most cephalad point on the visible anterosuperior surface of the humeral head and coracoid process in seven healthy volunteers. GHJ stiffness was defined as the slope of the linear regression line between the glides and different testing loads. The testing conditions were defined by different test loading mechanisms (n=2), shoulder constraining conditions (n=2), and loading modes (n=4). The optimal testing condition was defined as the condition with the least residual variance of measured laxity to the calculated stiffness under different testing loads. A paired t-test was used to compare the laxity and stiffness of the inferior GHJ using different braces. No significant difference was identified between the two test loading mechanisms (t=0.218, p=0.831) and two shoulder constraining conditions (t=-0.235, p=0.818). We concluded that ultrasonographic laxity measurements performed using a pulley set loading mechanism was as reliable as direct loading. Additionally, constraining the unloaded shoulder was proposed due to the lower mean residual variance value. Moreover, pulling the elbow downward with loading on the upper arm was suggested, as pulling the elbow downward with the elbow flexed and loading on the forearm may overestimate stiffness

  4. Measurement of joint space width and erosion size

    NARCIS (Netherlands)

    Sharp, JI; van der Heijde, D; Angwin, J; Duryea, J; Moens, HJB; Jacobs, JWG; Maillefert, JF; Strand, CV

    2005-01-01

    Measurement of radiographic abnormalities in metric units has been reported by several investigators during the last 15 years. Measurement of joint space in large joints has been employed in a few trials to evaluate therapy in osteoarthritis. Measurement of joint space width in small joints has been

  5. Principles of human joint replacement design and clinical application

    CERN Document Server

    Buechel, Frederick F

    2015-01-01

    This book is written for the users and designers of joint replacements. In its second extended edition it conveys to the reader the knowledge accumulated by the authors during their forty year effort on the development of replacement devices for the lower limb for the purpose of aiding the reader in their design and evaluation of joint replacement devices. The early chapters describe the engineering, scientific and medical principles needed for replacement joint evaluation. One must understand the nature and performance of the materials involved and their characteristics in vivo, i.e. the response of the body to implant materials. It is also essential to understand the response of the implants to applied loading and motion, particularly in the hostile physiological environment. A chapter describes the design methodology now required for joint replacement in the USA and EU countries. The remaining chapters provide a history of joint replacement, an evaluation of earlier and current devices and sample case hist...

  6. Thorax deformity, joint hypermobility and anxiety disorder

    International Nuclear Information System (INIS)

    Gulsun, M.; Dumlu, K.; Erbas, M.; Yilmaz, Mehmet B.; Pinar, M.; Tonbul, M.; Celik, C.; Ozdemir, B.

    2007-01-01

    Objective was to evaluate the association between thorax deformities, panic disorder and joint hypermobility. The study includes 52 males diagnosed with thorax deformity, and 40 healthy male controls without thorax deformity, in Tatvan Bitlis and Isparta, Turkey. The study was carried out from 2004 to 2006. The teleradiographic and thoracic lateral images of the subjects were evaluated to obtain the Beighton scores; subjects psychiatric conditions were evaluated using the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-1), and the Hamilton Anxiety Scale (HAM-A) was applied in order to determine the anxiety levels. Both the subjects and controls were compared in sociodemographic, anxiety levels and joint mobility levels. In addition, males with joint hypermobility and thorax deformity were compared to the group with thorax deformity without joint hypermobility. A significant difference in HAM-A scores was found between the groups with thorax deformity and without. In addition, 21 subjects with thorax deformity met the joint hypermobility criteria in the group with thorax deformity and 7 subjects without thorax deformity met the joint hypermobility criteria in the group without thorax deformity, according to Beighton scoring. The Beighton score of subjects with thorax deformity were significantly different from those of the group without deformity. Additionally, anxiety scores of the males with thorax deformity and joint hypermobility were found higher than males with thorax deformity without joint hypermobility. Anxiety disorders, particularly panic disorder, have a significantly higher distribution in males subjects with thorax deformity compared to the healthy control group. In addition, the anxiety level of males with thorax deformity and joint hypermobility is higher than males with thorax deformity without joint hypermobility. (author)

  7. The Jeff evaluated nuclear data project

    Energy Technology Data Exchange (ETDEWEB)

    Koning, A.J.; Duijvestijn, M.C.; Hogenbirk, A.; Van der Marck, S.C.; Avrigeanu, M.; Avrigeanu, V.; Batistoni, P.; Pillon, M.; Bauge, E.; Bersillon, O.; Dos-Santos-Uzarralde, P.; Lopez Jimenez, M.J.; Morillon, B.; Romain, P.; Be, M.M.; Duchemin, B.; Huynh, T.D.; Jouanne, C.; Mounier, C.; Bem, P.; Bernard, D.; Bouland, O.; Courcelle, A.; Dupont, E.; Jacqmin, R.; Litaize, O.; Noguere, G.; Saint Jean, C. de; Santamarina, A.; Serot, O.; Sublet, J.Ch.; Bidaud, A.; Dean, C.J.; Perry, R.J.; Duhamel, I.; Nouri, A.; Gunsing, F.; Ridikas, D.; Fischer, U.; Leichtle, D.; Pereslavtsev, P.; Simakov, S.; Forrest, R.A.; Haeck, W.; Henriksson, H.; Kodeli, I.; Nordborg, C.; Rugama, Y.; Sartori, E.; Keinert, J.; Mattes, M.; Kellett, M.A.; Nichols, A.L.; Kopecky, J.; Leeb, H.; Leppanen, J.; Menapace, E.; Pescarini, M.; Mills, R.W.; Perel, R.L.; Plompen, A.J.M.; Rullhusen, P.; Seidel, K.; Tagesen, S.; Vonach, H.; Trkov, A

    2008-07-01

    The status of the Joint Evaluated Fission and Fusion file (JEFF) is described. JEFF-3.1 comprises a significant update of actinide evaluations, materials evaluations that have emerged from various European nuclear data projects, the activation library JEFF-3.1/A, the decay data and fission yield sub-libraries, and fusion-related data files from the EFF project. The revisions were motivated by the availability of new measurements, modelling capabilities and trends from integral experiments. Validations have been performed, mainly for criticality, reactivity temperature coefficients, fuel inventory and shielding of thermal and fast systems. Compared with earlier releases, JEFF-3.1 provides improved performance with respect to a variety of scientific and industrial applications. Following on from the public release of JEFF-3.1, the French nuclear power industry has selected this suite of nuclear applications libraries for inclusion in their production codes. (authors)

  8. The Jeff evaluated nuclear data project

    International Nuclear Information System (INIS)

    Koning, A.J.; Duijvestijn, M.C.; Hogenbirk, A.; Van der Marck, S.C.; Avrigeanu, M.; Avrigeanu, V.; Batistoni, P.; Pillon, M.; Bauge, E.; Bersillon, O.; Dos-Santos-Uzarralde, P.; Lopez Jimenez, M.J.; Morillon, B.; Romain, P.; Be, M.M.; Duchemin, B.; Huynh, T.D.; Jouanne, C.; Mounier, C.; Bem, P.; Bernard, D.; Bouland, O.; Courcelle, A.; Dupont, E.; Jacqmin, R.; Litaize, O.; Noguere, G.; Saint Jean, C. de; Santamarina, A.; Serot, O.; Sublet, J.Ch.; Bidaud, A.; Dean, C.J.; Perry, R.J.; Duhamel, I.; Nouri, A.; Gunsing, F.; Ridikas, D.; Fischer, U.; Leichtle, D.; Pereslavtsev, P.; Simakov, S.; Forrest, R.A.; Haeck, W.; Henriksson, H.; Kodeli, I.; Nordborg, C.; Rugama, Y.; Sartori, E.; Keinert, J.; Mattes, M.; Kellett, M.A.; Nichols, A.L.; Kopecky, J.; Leeb, H.; Leppanen, J.; Menapace, E.; Pescarini, M.; Mills, R.W.; Perel, R.L.; Plompen, A.J.M.; Rullhusen, P.; Seidel, K.; Tagesen, S.; Vonach, H.; Trkov, A.

    2008-01-01

    The status of the Joint Evaluated Fission and Fusion file (JEFF) is described. JEFF-3.1 comprises a significant update of actinide evaluations, materials evaluations that have emerged from various European nuclear data projects, the activation library JEFF-3.1/A, the decay data and fission yield sub-libraries, and fusion-related data files from the EFF project. The revisions were motivated by the availability of new measurements, modelling capabilities and trends from integral experiments. Validations have been performed, mainly for criticality, reactivity temperature coefficients, fuel inventory and shielding of thermal and fast systems. Compared with earlier releases, JEFF-3.1 provides improved performance with respect to a variety of scientific and industrial applications. Following on from the public release of JEFF-3.1, the French nuclear power industry has selected this suite of nuclear applications libraries for inclusion in their production codes. (authors)

  9. Evaluation of Creep Strength of Heterogeneous Welded Joint in HR6W Alloy and Sanicro 25 Steel

    Directory of Open Access Journals (Sweden)

    Zieliński A.

    2017-12-01

    Full Text Available This article presents the results of investigations on HR6W alloy and Sanicro 25 steel and the dissimilar welded joint made of them. The characteristic images of microstructure of the investigated materials in the as-received condition and following the creep test, observed with a scanning electron microscope (SEM, are shown. The X-ray analysis of phase composition of the existing precipitates was carried out. The method for evaluation of creep strength based on abridged creep tests carried out at a temperature higher than the design one is presented. The obtained results do not deviate from the values of creep strength determined in long-term creep tests. The maximum difference in creep strength of the investigated materials is ±20%, which is in compliance with the acceptable scatter band. The methodology presented can be used for verification of creep strength (life time of the material of finished components to be operated under creep conditions.

  10. Equilibrium blood pool scanning in the evaluation of hemophilic arthropathy

    International Nuclear Information System (INIS)

    Spies, S.; Green, D.; Rana, N.A.; Milgram, J.W.; Mintzer, R.

    1978-01-01

    Arthropathy was evaluated in six patients with severe hemophilia (factor VIII<1%) using the technique of blood pool scanning. Employing an in vivo method for erythrocyte labelling with technetium-99m, a dynamic perfusion sequence was obtained using a scintillation camera over the joint(s) to be examined. Subsequently, equilibrium blood pool images of the joints were obtained to determine regional blood volume. In young patients with repeated episodes of acute hemarthrosis, increased vascularity and increased blood pool in the affected joints were demonstrated. In older patients with fixed, contracted joints and degenerative arthropathy, vascularity and regional blood volume were not abnormal. Blood pool scanning is a safe, non-invasive technique that augments the clinical and radiographic examination of the joints. The method is helpful in distinguishing acute joint bleeding from chronic synovitis and arthritis, and may prove useful in selecting patients for synovectomy. (author)

  11. Gas research programme in Sweden 1994-1996. Evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    Hustad, J E [Norwegian Univ. of Science and Technology, Trondheim (Norway); Jahkola, A [Helsinki Univ. of Technology (Finland); Norhammar, U [STOSEB (Sweden)

    1997-05-01

    This evaluation report is written by an international committee at the request of the Swedish National Board for Industrial and Technical Development (NUTEK). The committee was invited to look into the quality of a research programme funded jointly by Svenskt Gastekniskt Center SGC (Swedish Gas Technical Centre) and NUTEK. Criteria`s considered in the evaluation have in short been as follows: scientific value of the projects and of the results obtained; merits of the methods; capability of research groups and adequacy of resources; quality of research in the view of problem oriented applied research; necessity of future financial support. Although the projects are the main elements to be evaluated, the evaluators have paid attention to structural and other problems wherever such a need has been seen.

  12. Evaluation of the finite element software ABAQUS for biomechanical modelling of biphasic tissues.

    Science.gov (United States)

    Wu, J Z; Herzog, W; Epstein, M

    1998-02-01

    The biphasic cartilage model proposed by Mow et al. (1980) has proven successful to capture the essential mechanical features of articular cartilage. In order to analyse the joint contact mechanics in real, anatomical joints, the cartilage model needs to be implemented into a suitable finite element code to approximate the irregular surface geometries of such joints. However, systematic and extensive evaluation of the capacity of commercial software for modelling the contact mechanics with biphasic cartilage layers has not been made. This research was aimed at evaluating the commercial finite element software ABAQUS for analysing biphasic soft tissues. The solutions obtained using ABAQUS were compared with those obtained using other finite element models and analytical solutions for three numerical tests: an unconfined indentation test, a test with the contact of a spherical cartilage surface with a rigid plate, and an axi-symmetric joint contact test. It was concluded that the biphasic cartilage model can be implemented into the commercial finite element software ABAQUS to analyse practical joint contact problems with biphasic articular cartilage layers.

  13. Evaluation of shelf arthroplasty as a treatment for hip dysplasia in dogs.

    Science.gov (United States)

    Oakes, M G; Lewis, D D; Elkins, A D; Hosgood, G; Dial, S M; Oliver, J

    1996-06-01

    To evaluate effects of shelf arthroplasty on coxofemoral joint laxity and progression of degenerative joint disease in young dogs with hip dysplasia. Prospective, controlled study. 10 dogs between 10 and 24 months old and weighing between 20 and 27 kg. All dogs had bilateral coxofemoral joint laxity (i.e., an Ortolani's sign). In all dogs, shelf arthroplasty was performed on the right coxofemoral joints, and a sham procedure was performed on the left. Dogs were evaluated before and after surgery by means of lameness assessment, coxofemoral joint palpation and goniometry, thigh circumference measurement, and radiography. There were no significant changes in coxofemoral joint mobility, range of motion, joint laxity, degree of degenerative joint disease, or thigh circumference during the study. A greater amount of periacetabular bone formed on the right side than on the left side; however, dogs did not develop large bony shelves, and the amount of periarticular bone decreased over time. The polymer implants remained in their original position and were encapsulated by fibrous tissue. There was no histologic evidence of osteoconduction by the implants. The polymer implants used in this procedure do not appear to be osteoconductive. Shelf arthroplasty was associated with minimal morbidity and was not associated with serious adverse sequelae in this study, but the procedure did not alter the progression of hip dysplasia in these dogs. We cannot advocate shelf arthroplasty using this polymer as a treatment for dogs with hip dysplasia.

  14. The Management Evaluation-Control Function of Joint Stock Comapanies

    OpenAIRE

    RADA Ioan Constantin; PACALA Anca

    2011-01-01

    Albert Schweitzer once wrote: “You need to teach people through the power of examples, because otherwise they will not learn”. It’s demonstrated that over the course of time, the example you impose through your character, attitude, personality, professional habits and especially through your behavior with people sets the pace in the department or organization you are in charge of. Managers don’t need to establish a certain moral among organizations (joint stock companies); a slogan circulates...

  15. Health economic evaluation in Greece.

    Science.gov (United States)

    Rovithis, Dimitrios

    2006-01-01

    There is a growing volume of literature on health economic evaluation, with this form of analysis becoming increasingly influential at the decision-making level worldwide. The purpose of this study was to review the current state of health economic evaluation in Greece, with a view to uncovering reasons why its use in this country is limited. A search of the NHS Economic Evaluation Database was undertaken. The search included cost, cost-of-illness, cost-minimization, cost-effectiveness, cost-consequences, cost-utility, and cost-benefit analyses and was narrowed only to Greek authors undertaking solo or joint health economic evaluation in Greece. The search revealed that, in Greece, very little health economic evaluation has been undertaken. The main reason for the lack of interest is that the current chaotic healthcare system structure and financing does not provide the appropriate incentives to stimulate a powerful interest in this type of research. This condition is a result of the lack of a long-term national health policy and the hesitation of the present and past Greek governments to date to proceed to large-scale reforms because of political considerations. The Greek governments have also been content with the good health indicators being achieved. Even if it is accepted that good health prevails in Greece, slower economic growth rates, an ageing population, and the continuous immigration will place increasing pressure on healthcare resources and will necessitate a more rational use of these resources. Health economic evaluation, by weighing benefits against costs, therefore, has an important role to play.

  16. The evaluation of external costs from energy sources

    International Nuclear Information System (INIS)

    Lee, R.; Valette, P.; Krupnick, A.; Markandya, A.

    1994-01-01

    The paper outlines the progress of the joint EC-US Fuel Cycle study. This study seeks to provide a methodological framework for precisely the evaluation of external costs over the complete fuel cycle, from fuel extraction to decommissioning, conservation technologies, solar and wind power. (authors). 19 refs., 4 figs

  17. Evaluation of wall thinning profile by flow accelerated corrosion in separation and union pipe

    International Nuclear Information System (INIS)

    Watanabe, Shun; Yoneda, Kimitoshi

    2013-01-01

    Flow Accelerated Corrosion (FAC) is a pipe wall thinning phenomena to be monitored and managed in power plants with high priority. At present, its management has been conducted with conservative evaluation of thinning rate and residual lifetime of the piping based on wall thickness measurements. However, noticeable case of wall thinning was occurred at separation and union pipe. In such pipe system, it is a problem to manage section beneath reinforcing plate of T-tube pipe and 'crotch' of T-joint pipe; the region where wall thickness measurement is difficult to conduct with ordinary ultrasonic testing device. In this study, numerical analysis for separation and union part of T-tube and T-joint pipe was conducted, and wall thinning profile by Flow Accelerated Corrosion was evaluated by calculating mass transfer coefficient and geometry factor. Based on these results, we considered applicable wall thinning management for T-tube and T-joint pipe. In the case of union flow from main and branch pipe, the wall thinning profile of T-tube showed the tendency of increase at main pipe like semielliptical region. On the other hand, noticeable profile appeared at 'crotch' in T-joint. Although it was found that geometry factor of T-joint in this case was half the value of T-tube, an alternative evaluation method to previous one might be needed for the profiles of 'semielliptical region' and 'crotch'. (author)

  18. Temporomandibular joint examination reviewed

    Directory of Open Access Journals (Sweden)

    L. Guarda Nardini

    2011-09-01

    Full Text Available The temporo-mandibular joint (TMJ it’s a joint closely related to the skull base, the spine, and the jaws; all these anatomical structures must be taken in consideration when evaluating pain involving the tmj. In order to detect patients affected by pathology or dysfunctions of the tmj, physical examination is of great value in orienting the diagnosis. Inspection must consider the symmetry of the body, the dental status and the type of occlusion. Palpation is a way to assess contractiont involving the muscles of the masticatory system and of the neck. Auscultation, based on articular noise provides means to determine whether we are dealing with degeneration of the joint or a dislocation of the intrarticular disc. In order to confirm the diagnosis obtained with the clinical evaluation, it’s useful to perform imaging techniques as opt, tomography and TC of the tmj and electromyokineosiography – index of the mandibular functionality and of the muscles status. MRI and dynamic MRI are among the non invasive exams which give the greatest amount of information, regarding the disc position and the joint degeneration. Arthroscopy is an invasive technique that allows early diagnosis of degeneration and is helpful to reveal early inflammatory processes of the joint.

  19. Single and joint action toxicity evaluation of insecticide and laundry ...

    African Journals Online (AJOL)

    Further analysis based on the isobologram model was in conformity with RTU and SR models. The significance of this study showed the relevance of joint action toxicity studies in setting realistic safe limits in order to protect aquatic organisms. Therefore, proper disposal and management strategies for wastes should be ...

  20. Radiology of disorders of the sacroiliac joints

    International Nuclear Information System (INIS)

    Resnik, C.S.; Resnick, D.

    1985-01-01

    Many disorders can lead to radiological abnormalities of the sacroiliac joints. Some present a characteristic appearance, while others may be diagnosed by analyzing both the appearance and the distribution of findings. Computed tomography provides excellent visualization of the sacroiliac joints and can be helpful in the evaluation of articular disorders as well as pelvic trauma and neoplasms. Radionuclide scanning of bone can also be used to evaluate the sacroiliac joints, particularly if the two sides are compared with the assistance of computer-generated activity counts. This article describes the radiological features of these various disorders that often allow an exact diagnosis to be made

  1. SWOT analysis to evaluate the programme of a joint online/onsite master's degree in environmental education through the students' perceptions.

    Science.gov (United States)

    Romero-Gutierrez, Miguel; Jimenez-Liso, M Rut; Martinez-Chico, Maria

    2016-02-01

    This study shows the use of SWOT to analyse students' perceptions of an environmental education joint master's programme in order to determine if it runs as originally planned. The open answers given by students highlight the inter-university nature of the master's, the technological innovation used as major points, and the weaknesses in the management coordination or the duplicate contents as minor points. The external analysis is closely linked with the students' future jobs, their labour opportunities available to them after graduation. The innovative treatment of the data is exportable to the evaluation of programmes of other degrees because it allows the description linked to its characteristics and its design through the students' point of view. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Applying the chronicle workshop as a method for evaluating participatory interventions

    DEFF Research Database (Denmark)

    Poulsen, Signe; Ipsen, Christine; Gish, Liv

    2015-01-01

    Despite the growing interest for process evaluation in participatory interventions, studies examining specific methods for process evaluation are lacking. In this paper, we propose a new method for process evaluation – the chronicle workshop. The chronicle workshop has not previously been used...... productivity and well-being. In all cases, we saw that the chronicle workshop gave valuable information about the intervention process and that it initiated a joint reflection among participants from different departments. The chronicle workshop makes it possible to better understand the results...

  3. Evaluation of stresses by neutron diffraction

    International Nuclear Information System (INIS)

    Lodini, A.; Perrin, M.

    1989-01-01

    The evaluation of stresses in the interfaces of bonded or welded joints can be carried out by three methods. The first two methods, where the main directions are presumed known, have been used to measure the main stresses in the plane of symmetry of a U-shaped part made from AU4G, which has been elastically deformed; and in the vicinity of the adhesive-metal interface in a specimen consisting of 2 parts in AU4G, which have been joint bonded and submitted to a tension load. The third, more general method determines a strain tensor, the diagonalization of which gives the directions and values of the main deformations. The results are compared with values calculated by the finite-element method [fr

  4. Evaluation of orthognathic surgery on articular disc position and temporomandibular joint symptoms in skeletal class II patients: A Magnetic Resonance Imaging study.

    Science.gov (United States)

    Firoozei, Gholamreza; Shahnaseri, Shirin; Momeni, Hasan; Soltani, Parisa

    2017-08-01

    The purpose of orthognathic surgery is to correct facial deformity and dental malocclusion and to obtain normal orofacial function. However, there are controversies of whether orthognathic surgery might have any negative influence on temporomandibular (TM) joint. The purpose of this study was to evaluate the influence of orthognathic surgery on articular disc position and temporomandibular joint symptoms of skeletal CI II patients by means of magnetic resonance imaging. For this purpose, fifteen patients with skeletal CI II malocclusion, aged 19-32 years (mean 23 years), 10 women and 5 men, from the Isfahan Department of Oral and Maxillofacial Surgery were studied. All received LeFort I and bilateral sagittal split osteotomy (BSSO) osteotomies and all patients received pre- and post-surgical orthodontic treatment. Magnetic resonance imaging was performed 1 day preoperatively and 3 month postoperatively. Descriptive statistics and Wilcoxon and Mc-Nemar tests were used for statistical analysis. P surgery (mean=5.74±1.21). After surgery disc position range was 4.36 to 7.40 (mean=5.65±1.06). Statistical analysis proved that although TM disc tended to move anteriorly after BSSO surgery, this difference was not statistically significant ( p valuesurgery does not alter the disc and condyle relationship. Therefore, it has minimal effects on intact and functional TM joint. Key words: Orthognathic surgery, skeletal class 2, magnetic resonance imaging, temporomandibular disc.

  5. Data Evaluation for Atomic, Molecular and Plasma Material Interaction Processes in Fusion. Summary Report of a Joint IAEA-NFRI Technical Meeting

    International Nuclear Information System (INIS)

    Chung, Hyun-Kyung

    2012-12-01

    This report summarizes the proceedings of the Joint IAEA-NFRI Technical Meeting on 'Data Evaluation for Atomic, Molecular and Plasma Material Interaction Processes in Fusion' on 4-7 September 2012. Twenty five participants from 10 Member States and two from the IAEA attended the four-day meeting held at the Daejeon Convention Center in Daejeon, Republic of Korea hosted by the National Fusion Research Institute (NFRI) in conjunction with the 8th International Symposium on Standard Reference Data. The report includes discussions on the issues of the critical assessment of fundamental data required for fusion and plasma applications, meeting conclusions and recommendations. The abstracts of presentations presented in the meeting are attached in the Appendix. (author)

  6. Preventive lateral ligament tester (PLLT): a novel method to evaluate mechanical properties of lateral ankle joint ligaments in the intact ankle.

    Science.gov (United States)

    Best, Raymond; Böhle, Caroline; Mauch, Frieder; Brüggemann, Peter G

    2016-04-01

    To construct and evaluate an ankle arthrometer that registers inversion joint deflection at standardized inversion loads and that, moreover, allows conclusions about the mechanical strain of intact ankle joint ligaments at these loads. Twelve healthy ankles and 12 lower limb cadaver specimens were tested in a self-developed measuring device monitoring passive ankle inversion movement (Inv-ROM) at standardized application of inversion loads of 5, 10 and 15 N. To adjust in vivo and in vitro conditions, the muscular inactivity of the evertor muscles was assured by EMG in vivo. Preliminary, test-retest and trial-to-trial reliabilities were tested in vivo. To detect lateral ligament strain, the cadaveric calcaneofibular ligament was instrumented with a buckle transducer. After post-test harvesting of the ligament with its bony attachments, previously obtained resistance strain gauge results were then transferred to tensile loads, mounting the specimens with their buckle transducers into a hydraulic material testing machine. ICC reliability considering the Inv-ROM and torsional stiffness varied between 0.80 and 0.90. Inv-ROM ranged from 15.3° (±7.3°) at 5 N to 28.3° (±7.6) at 15 N. The different tests revealed a CFL tensile load of 31.9 (±14.0) N at 5 N, 51.0 (±15.8) at 10 N and 75.4 (±21.3) N at 15 N inversion load. A highly reliable arthrometer was constructed allowing not only the accurate detection of passive joint deflections at standardized inversion loads but also reveals some objective conclusions of the intact CFL properties in correlation with the individual inversion deflections. The detection of individual joint deflections at predefined loads in correlation with the knowledge of tensile ligament loads in the future could enable more individual preventive measures, e.g., in high-level athletes.

  7. Sample Exchange Evaluation (SEE) Report - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Winters, W.I.

    1994-09-28

    This report describes the results from Phase II of the Sample Exchange Evaluation (SEE) Program, a joint effort to compare analytical laboratory performance on samples from the Hanford Site`s high-level waste tanks. In Phase II, the program has been expanded to include inorganic constituents in addition to radionuclides. Results from Phase II that exceeded 20% relative percent difference criteria are identified.

  8. Sample Exchange Evaluation (SEE) Report - Phase II

    International Nuclear Information System (INIS)

    Winters, W.I.

    1994-01-01

    This report describes the results from Phase II of the Sample Exchange Evaluation (SEE) Program, a joint effort to compare analytical laboratory performance on samples from the Hanford Site's high-level waste tanks. In Phase II, the program has been expanded to include inorganic constituents in addition to radionuclides. Results from Phase II that exceeded 20% relative percent difference criteria are identified

  9. Evaluation models and evaluation use

    Science.gov (United States)

    Contandriopoulos, Damien; Brousselle, Astrid

    2012-01-01

    The use of evaluation results is at the core of evaluation theory and practice. Major debates in the field have emphasized the importance of both the evaluator’s role and the evaluation process itself in fostering evaluation use. A recent systematic review of interventions aimed at influencing policy-making or organizational behavior through knowledge exchange offers a new perspective on evaluation use. We propose here a framework for better understanding the embedded relations between evaluation context, choice of an evaluation model and use of results. The article argues that the evaluation context presents conditions that affect both the appropriateness of the evaluation model implemented and the use of results. PMID:23526460

  10. Evaluation of Kinesiophobia and Its Correlations with Pain and Fatigue in Joint Hypermobility Syndrome/Ehlers-Danlos Syndrome Hypermobility Type

    Directory of Open Access Journals (Sweden)

    Claudia Celletti

    2013-01-01

    Full Text Available Ehlers-Danlos syndrome hypermobility type a. k. a. joint hypermobility syndrome (JHS/EDS-HT is a hereditary musculoskeletal disorder associating generalized joint hypermobility with chronic pain. Anecdotal reports suggest a prominent role for kinesiophobia in disease manifestations, but no study has systematically addressed this point. Objective. To investigate the impact of kinesiophobia and its relationship with pain, fatigue, and quality of life in JHS/EDS-HT. Design. Cross-sectional study. Subjects/Patients. 42 patients (40 female and 2 male with JHS/EDS-HT diagnosis following standardized diagnostic criteria were selected. Methods. Disease features were analyzed by means of specific questionnaires and scales evaluating kinesiophobia, pain, fatigue, and quality of life. The relationships among variables were investigated using the Spearman bivariate analysis. Results. Kinesiophobia resulted predominantly in the patients’ sample. The values of kinesiophobia did not correlate with intensity of pain, quality of life, and (or the single component of fatigue. A strong correlation was discovered between kinesiophobia and general severity of fatigue. Conclusions. In JHS/EDS-HT, the onset of pain-avoiding strategies is related to the presence of pain but not to its intensity. The clear-cut correlation between kinesiophobia and severity of fatigue suggests a direct link between musculoskeletal pain and fatigue. In JHS/EDS-HT, the underlying mechanism is likely to be facilitated by primary disease characteristics, including hypotonia.

  11. Evaluation of the walking pattern in clubfoot patients who received early intensive treatment

    DEFF Research Database (Denmark)

    Alkjaer, T; Pedersen, E N; Simonsen, E B

    2000-01-01

    joint in the clubfeet could possibly be owing to weaker plantar flexors. In conclusion, gait analysis can be an important tool when evaluating treatment for clubfoot. However, further investigation is needed to determine whether the higher hip and knee joint moments observed in subjects with clubfoot...... in the two groups. However, analysis revealed a smaller ankle joint moment and larger knee and hip joint moments in those with clubfoot. It was concluded that the larger knee and hip joint moments served as compensation for the smaller ankle moment. The reduced ankle moment and work developed about the ankle...

  12. MAGNETIC RESONANCE IMAGING EVALUATION OF ROTATOR CUFF IMPINGEMENT

    Directory of Open Access Journals (Sweden)

    Chandrakanth K. S

    2017-06-01

    Full Text Available BACKGROUND Shoulder pain is a common clinical problem. Impingement syndrome of the shoulder is believed to be the most common cause of shoulder pain. The term ‘impingement syndrome’ was first used by Neer to describe a condition of shoulder pain associated with chronic bursitis and partial thickness tear of Rotator Cuff (RC. The incidence of Rotator Cuff (RC tear is estimated to be about 20.7% in the general population. This study is intended to analyse various extrinsic and intrinsic causes of shoulder impingement. MATERIALS AND METHODS 110 consecutive patients referred for MRI with clinical suspicion of shoulder impingement were prospectively studied. All the patients were evaluated for Rotator Cuff (RC degeneration and various extrinsic factors that lead to degeneration like acromial shape, down-sloping acromion, Acromioclavicular (AC joint degeneration and acromial enthesophyte. Intrinsic factors like degeneration and its correlation with age of the patients were evaluated. RESULTS Of the total 110 patients, 19 (17.3% patients had FT RC tear and 31 (28.2% had PT (both bursal and articular surface tears. There was no statistically significant correlation (p=0.76 between acromion types and RC tear. Down-sloping acromion and enthesophytes had statistically significant association with RC tear (p=0.008 and 0.008, respectively. Statistically significant (0.008 correlation between the severity of AC joint degeneration and RC tears was noted. AC joint degeneration and RC pathologies also showed a correlation with the age of the patients with p values of <0.001 and 0.001, respectively. CONCLUSION No statistically significant correlation between RC pathologies with hooked acromion was found, that makes the role played by hooked acromion in FT RC tear questionable. AC joint degeneration association with RC tear is due to the association of both RC tear and AC joint degeneration with age of the patient. Down-sloping acromion, AC joint degeneration

  13. Evaluation Use in Evaluation Systems

    DEFF Research Database (Denmark)

    Højlund, Steven

    2014-01-01

    This article investigates the European Union’s evaluation system and its conduciveness to evaluation use. Taking the European Commission’s LIFE programme as its case, the article makes an empirical contribution to an emerging focus in the literature on the importance of organization...... and institutions when analyzing evaluation use. By focusing on the European Union’s evaluation system the article finds that evaluation use mainly takes place in the European Commission and less so in the European Parliament and the European Council. The main explanatory factors enabling evaluation use relate...... to the system’s formalization of evaluation implementation and use; these factors ensure evaluation quality, timeliness and capacity in the Commission. At the same time, however, the system’s formalization also impedes evaluation use, reducing the direct influence of evaluations on policy-making and effectively...

  14. Evaluation of certain food additives and contaminants. Eightieth report of the Joint FAO/WHO Expert Committee on Food Additives.

    Science.gov (United States)

    2016-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives and contaminants and to prepare specifications for identity and purity. The first part of the report contains a brief description of general considerations addressed at the meeting, including updates on matters of interest to the work of the Committee. A summary follows of the Committee's evaluations of technical, toxicological and/or dietary exposure data for seven food additives (benzoates; lipase from Fusarium heterosporum expressed in Ogataea polymorpha; magnesium stearate; maltotetraohydrolase from Pseudomonas stutzeri expressed in Bacillus licheniformis; mixed β-glucanase, cellulase and xylanase from Rasamsonia emersonii; mixed β-glucanase and xylanase from Disporotrichum dimorphosporum; polyvinyl alcohol (PVA)- polyethylene glycol (PEG) graft copolymer) and two groups of contaminants (non-dioxin-like polychlorinated biphenyls and pyrrolizidine alkaloids). Specifications for the following food additives were revised or withdrawn: advantame; annatto extracts (solavnt extracted bixin, ad solvent-extracted norbixin); food additives containing aluminium and/or silicon (aluminium silicate; calcium aluminium silicate; calcium silicate; silicon dioxide, amorphous; sodium aluminium silicate); and glycerol ester of gum rosin. Annexed to the report are tables or text summarizing the toxicological and dietary exposure information and information on specifications as well as the Committees recommendations on the food additives and contaminants considered at this meeting.

  15. Probabilistic evaluation of design S-N curve and reliability assessment of ASME code-based evaluation

    International Nuclear Information System (INIS)

    Zhao Yongxiang

    1999-01-01

    A probabilistic evaluating approach of design S-N curve and a reliability assessment approach of the ASME code-based evaluation are presented on the basis of Langer S-N model-based P-S-N curves. The P-S-N curves are estimated by a so-called general maximum likelihood method. This method can be applied to deal with the virtual stress amplitude-crack initial life data which have a characteristics of double random variables. Investigation of a set of the virtual stress amplitude-crack initial life (S-N) data of 1Cr18Ni9Ti austenitic stainless steel-welded joint reveals that the P-S-N curves can give a good prediction of scatter regularity of the S-N data. Probabilistic evaluation of the design S-N curve with 0.9999 survival probability has considered various uncertainties, besides of the scatter of the S-N data, to an appropriate extent. The ASME code-based evaluation with 20 reduction factor on the mean life is much more conservative than that with 2 reduction factor on the stress amplitude. Evaluation of the latter in 666.61 MPa virtual stress amplitude is equivalent to 0.999522 survival probability and in 2092.18 MPa virtual stress amplitude equivalent to 0.9999999995 survival probability. This means that the evaluation in the low loading level may be non-conservative and in contrast, too conservative in the high loading level. Cause is that the reduction factors are constants and the factors can not take into account the general observation that scatter of the N data increases with the loading level decreasing. This has indicated that it is necessary to apply the probabilistic approach to the evaluation of design S-N curve

  16. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  17. Evaluation of certain food additives.

    Science.gov (United States)

    2017-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives, including flavouring agents, with a view to concluding as to safety concerns and to preparing specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation of and assessment of dietary exposure to food additives, including flavouring agents. A summary follows of the Committee’s evaluations of technical, toxicological and dietary exposure data for 10 food additives (Allura Red AC; carob bean gum; lutein esters from Tagetes erecta; octenyl succinic acid (OSA)– modified gum arabic; pectin; Quinoline Yellow; rosemary extract; steviol glycosides; tartrazine; and xanthan gum) and five groups of flavouring agents (alicyclic, alicyclic-fused and aromatic-fused ring lactones; aliphatic and aromatic amines and amides; aliphatic secondary alcohols, ketones and related esters; cinnamyl alcohol and related substances; and tetrahydrofuran and furanone derivatives). Specifications for the following food additives were revised: aspartame; cassia gum; citric and fatty acid esters of glycerol (CITREM); modified starches; octanoic acid; starch sodium octenyl succinate; and total colouring matters. Annexed to the report are tables summarizing the Committee’s recommendations for dietary exposures to and toxicological evaluations of all of the food additives, including flavouring agents, considered at this meeting.

  18. Collateral ligament strains during knee joint laxity evaluation before and after TKA.

    Science.gov (United States)

    Delport, Hendrik; Labey, Luc; De Corte, Ronny; Innocenti, Bernardo; Vander Sloten, Jos; Bellemans, Johan

    2013-08-01

    Passive knee stability is provided by the soft tissue envelope. There is consensus among orthopedic surgeons that good outcome in Total Knee Arthroplasty requires equal tension in the medial/lateral compartment of the knee joint, as well as equal tension in the flexion/extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after Posterior-Stabilized Total Knee Arthroplasty. We hypothesized that the Medial/Lateral Collateral Ligament shows minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to reconstruct using a Posterior-Stabilized Total Knee. Six specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. This study enabled a precise measurement of varus-valgus laxity as compared with the clinical assessment. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the Medial Collateral Ligament tends to relax and the Lateral Collateral Ligament remains tight. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend to avoid overstuffing the joint, when using this type of Posterior-Stabilized Total Knee Arthroplasty, in order to obtain varus/valgus laxity close to the native joint. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Design and strength evaluation of structural joint made by electro-magnetic forming (EMF)

    International Nuclear Information System (INIS)

    Park, Young-Bae; Oh, Soo-Ik; Kim, Heon-Young

    2004-01-01

    Recently, weight reduction of vehicles has been of great interest, and consequently, the use of low-density materials in the automotive industry is increasing every year. Materials should not be substituted such a way that material of component parts is simply changed because there is a problem in achieving stiffness and strength. To achieve these requirements, the automobile should be redesigned totally. Aluminum spaceframe is rapidly being adopted as a body structure for accommodating lightness, stiffness and strength requirement. In aluminum spaceframe manufacturing, it is often required to join aluminum tube. But there are few suitable methods for joining aluminum tube, so that much interest has been focused on testing suitable joining methods. Joining by electromagnetic forming(EMF) can be useful method in joining aluminum tube, which offers some advantages compared with the conventional joining method. In this paper, joining by EMF was investigated as a pre-study for applying an automotive spaceframe. Finite element simulations and strength tests were performed to analyze the influence of geometric parameters on joint strength. Based on these results, configurations of axial joint and torque joint were suggested and guidelines for designing EMF joint were established

  20. Statistical evaluation of design-error related accidents

    International Nuclear Information System (INIS)

    Ott, K.O.; Marchaterre, J.F.

    1980-01-01

    In a recently published paper (Campbell and Ott, 1979), a general methodology was proposed for the statistical evaluation of design-error related accidents. The evaluation aims at an estimate of the combined residual frequency of yet unknown types of accidents lurking in a certain technological system. Here, the original methodology is extended, as to apply to a variety of systems that evolves during the development of large-scale technologies. A special categorization of incidents and accidents is introduced to define the events that should be jointly analyzed. The resulting formalism is applied to the development of the nuclear power reactor technology, considering serious accidents that involve in the accident-progression a particular design inadequacy

  1. Clinical efficacy of radiation synovectomy in digital joint osteoarthritis

    International Nuclear Information System (INIS)

    Kampen, Willm Uwe; Hellweg, Leif; Massoudi-Nickel, Schirin; Czech, Norbert; Henze, Eberhard; Brenner, Winfried

    2005-01-01

    Radiation synovectomy was developed for local treatment of rheumatoid arthritis. In this study, the long-term efficacy of radiation synovectomy was retrospectively evaluated in patients with osteoarthritis (activated arthrosis) of the digital joints using an algofunctional score. Fifty-three digital joints in 29 patients (mean age 64.8 years) were treated by intra-articular injection of 169 Er citrate. All joints were painful despite pharmacotherapy and showed an elevated blood pool pattern in a pretherapeutic three-phase bone scan, indicative for local synovitis. The patients were asked to classify their complaints with respect to different daily manual activities on a ten-step pain scale from 1 (total disability) to 10 (lack of any impairment) prior to and after treatment, with a mean follow-up of 41 months. Local signs of osteoarthritis such as joint swelling or pain were additionally evaluated and were scored from progression of complaints to excellent improvement based on patient self-evaluation. All patients reported a pronounced improvement in their manual activities. The mean total score of 4.73±0.58 for all activities prior to treatment increased significantly to 6.79±0.47 after radiation synovectomy (p<0.05). The best results were obtained in the thumb base joints, whereas distal interphalangeal joints were frequently resistant to therapy. Radiation synovectomy is highly effective in digital joint osteoarthritis with concomitant local synovitis. (orig.)

  2. Clinical efficacy of radiation synovectomy in digital joint osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kampen, Willm Uwe; Hellweg, Leif; Massoudi-Nickel, Schirin; Czech, Norbert; Henze, Eberhard [University Hospital Schleswig-Holstein, Clinic of Nuclear Medicine, Kiel (Germany); Brenner, Winfried [University Hospital Hamburg-Eppendorf, Department of Nuclear Medicine (Germany)

    2005-04-01

    Radiation synovectomy was developed for local treatment of rheumatoid arthritis. In this study, the long-term efficacy of radiation synovectomy was retrospectively evaluated in patients with osteoarthritis (activated arthrosis) of the digital joints using an algofunctional score. Fifty-three digital joints in 29 patients (mean age 64.8 years) were treated by intra-articular injection of{sup 169}Er citrate. All joints were painful despite pharmacotherapy and showed an elevated blood pool pattern in a pretherapeutic three-phase bone scan, indicative for local synovitis. The patients were asked to classify their complaints with respect to different daily manual activities on a ten-step pain scale from 1 (total disability) to 10 (lack of any impairment) prior to and after treatment, with a mean follow-up of 41 months. Local signs of osteoarthritis such as joint swelling or pain were additionally evaluated and were scored from progression of complaints to excellent improvement based on patient self-evaluation. All patients reported a pronounced improvement in their manual activities. The mean total score of 4.73{+-}0.58 for all activities prior to treatment increased significantly to 6.79{+-}0.47 after radiation synovectomy (p<0.05). The best results were obtained in the thumb base joints, whereas distal interphalangeal joints were frequently resistant to therapy. Radiation synovectomy is highly effective in digital joint osteoarthritis with concomitant local synovitis. (orig.)

  3. A New Method for Determination of Joint Roughness Coefficient of Rock Joints

    Directory of Open Access Journals (Sweden)

    Shigui Du

    2015-01-01

    Full Text Available The joint roughness coefficient (JRC of rock joints has the characteristic of scale effect. JRC measured on small-size exposed rock joints should be evaluated by JRC scale effect in order to obtain the JRC of actual-scale rock joints, since field rock joints are hardly fully exposed or well saved. Based on the validity analysis of JRC scale effect, concepts of rate of JRC scale effect and effective length of JRC scale effect were proposed. Then, a graphic method for determination of the effective length of JRC scale effect was established. Study results show that the JRC of actual-scale rock joints can be obtained through a fractal model of JRC scale effect according to the statistically measured results of the JRC of small-size partial exposed rock joints and by the selection of fractal dimension of JRC scale effect and the determination of effective length of JRC scale effect.

  4. Making Evaluation Matter: Writings from South Asia | CRDI - Centre ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    27 avr. 2016 ... With representation from Afghanistan, Bangladesh, Nepal, India, Pakistan, and Sri Lanka, the Community of Evaluators first came together in 2008. Since then, it has worked jointly on a number of initiatives including cross-regional meetings and interaction forums, developing an active web platform, and ...

  5. European network for Health Technology Assessment Joint Action (EUnetHTA JA): a process evaluation performed by questionnaires and documentary analysis.

    Science.gov (United States)

    Woodford Guegan, Eleanor; Cook, Andrew

    2014-06-01

    The European network for Health Technology Assessment Joint Action (EUnetHTA JA) project's overarching objective was to 'establish an effective and sustainable HTA [Health technology assessment] collaboration in Europe that brings added value at the regional, national and European level'. Specific objectives were to develop a strategy and business model for sustainable European collaboration on HTA, develop HTA tools and methods and promote good practice in HTA methods and processes. We describe activities performed on behalf of the National Institute for Health Research HTA programme; evaluating the project processes and developing a data set for a registry of planned clinical studies of relevance to public funders. Annual self-completion online questionnaires were sent to project participants and external stakeholders to identify their views about the project processes. Documentary review was undertaken at the project end on the final technical reports from the work packages to examine whether or not their deliverables had been achieved. The project's impact was assessed by whether or not the deliverables were produced, the objectives met and additional 'added value' generated. The project's effectiveness was evaluated by its processes, communication, administration, workings of individual work packages and involvement of external stakeholders. A two-stage Delphi exercise was undertaken to identify the data elements that should be included in a registry of planned clinical studies of relevance to public funders. The data set was validated by an efficacy testing exercise. High response rates were achieved for the questionnaires sent to project participants and this was attributed to the evidence-based strategy implemented. Response rates to questionnaires sent to external stakeholders were disappointingly lower. Most of the high-level objectives were achieved, although applying the developed tools in practice will be implemented in the European network for Health

  6. Experimental evaluation of the prevention methods for the interface between masonry infill walls and concrete columns

    Directory of Open Access Journals (Sweden)

    A. P. Tramontin

    Full Text Available Cracks that form at the interfaces between masonry structures are common uncontrolled occurrences in buildings. Numerous methods have been proposed by the construction industry to address this problem. Cracks continuously form in the joints between concrete columns and masonry infill walls. In this study, the most common methods for preventing these types of cracks were evaluated in laboratory experiments. Column masonry models were constructed using different types of joints between concrete columns and masonry infill walls, such as steel bars and steel mesh. The efficiency of each type of joint method was evaluated by performing direct tensile tests (pullout tests on the models and monitoring the evolution of the crack opening in the joint between the column and wall, as a function of load applied to the model. The results from this study indicate that the model composed of "electrowelded wire mesh without steel angles" is the best model for controlling cracking in the joints between concrete columns and masonry infill walls.

  7. Evaluation of orthognathic surgery on articular disc position and temporomandibular joint symptoms in skeletal class II patients: A Magnetic Resonance Imaging study

    Science.gov (United States)

    Firoozei, Gholamreza; Shahnaseri, Shirin; Momeni, Hasan

    2017-01-01

    Background The purpose of orthognathic surgery is to correct facial deformity and dental malocclusion and to obtain normal orofacial function. However, there are controversies of whether orthognathic surgery might have any negative influence on temporomandibular (TM) joint. The purpose of this study was to evaluate the influence of orthognathic surgery on articular disc position and temporomandibular joint symptoms of skeletal CI II patients by means of magnetic resonance imaging. Material and Methods For this purpose, fifteen patients with skeletal CI II malocclusion, aged 19-32 years (mean 23 years), 10 women and 5 men, from the Isfahan Department of Oral and Maxillofacial Surgery were studied. All received LeFort I and bilateral sagittal split osteotomy (BSSO) osteotomies and all patients received pre- and post-surgical orthodontic treatment. Magnetic resonance imaging was performed 1 day preoperatively and 3 month postoperatively. Descriptive statistics and Wilcoxon and Mc-Nemar tests were used for statistical analysis. Psurgery (mean=5.74±1.21). After surgery disc position range was 4.36 to 7.40 (mean=5.65±1.06). Statistical analysis proved that although TM disc tended to move anteriorly after BSSO surgery, this difference was not statistically significant (p valueorthognathic surgery does not alter the disc and condyle relationship. Therefore, it has minimal effects on intact and functional TM joint. Key words:Orthognathic surgery, skeletal class 2, magnetic resonance imaging, temporomandibular disc. PMID:28936287

  8. Evaluation of mechanical vibration effect on the residual stresses levels in steel welded joints using an Interface Matlab based on Norm API 579

    Directory of Open Access Journals (Sweden)

    R Rodrigues

    2016-10-01

    Full Text Available Nowadays with the high growth of petrochemical welding technology a great development due to high manufacturing offshore structures, storage tanks of petroleum, boilers and pressure vessels for refining plants have been done. Due to various metallurgical changes and restrictions to contraction and expansion undergone by materials when subjected to welding thermal cycle, internal stresses are generated in welded joint which are nominated residual stresses. It is generally undesirable because it can lead to several problems, such as cracks, cold stress fracture, stress corrosion, among others. Although several studies involving residual stresses have been developed in recent years, few information about the variation of the residual stresses level in welded joints when subjected to stress relief treatment by mechanical vibration have been done. Likewise, there are few information related to the comparison between the degree of efficiency by using the post-weld heat treatment and those treatment. Therefore, the goal of this work was to apply the relieve residual stresses treatment by mechanical vibration in steel welded joints used in oil industry, and compare the results with those obtained by post heat treatment and evaluate the efficiency level of this technique In addition, this works also hope to contribute for a better understanding of this technique and to find which parameters have a greater influence on the results.

  9. Joint evaluation of communication quality and user experience in an audio-visual virtual reality meeting

    DEFF Research Database (Denmark)

    Møller, Anders Kalsgaard; Hoffmann, Pablo F.; Carrozzino, Marcello

    2013-01-01

    The state-of-the-art speech intelligibility tests are created with the purpose of evaluating acoustic communication devices and not for evaluating audio-visual virtual reality systems. This paper present a novel method to evaluate a communication situation based on both the speech intelligibility...

  10. The role of MRI in early ankylosing spondylitis: emphasis on the sacroiliac and hip joints

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chul Min; Kang, Moo Song; Kim, Chang Soo; Chung, Chun Phil [Maryknoll Hospital, Busan (Korea, Republic of)

    1995-05-15

    In clinically suspected ankylosing spondylitis of sacroiliac (SIJ) and hip joints with normal or minimal secondary bone change in simple X-ray films, we evaluated the role of MRI in sacroiliac and hip joints. Authors evaluated 11 cases (36 joints; SIJ 14 hip 22) confirmed as ankylosing spondylitis by clinical, laboratory, and radiologic findings, and compared the detectability of involvement of joints by simple X-ray film and MRI. Authors analysed MR findings for the presence of pannus and its signal intensities (SI), change of articular cartilage, bony erosion and sclerosis, subchondral bone cysts, osteophytosis, bone marrow edema, joint effusion, adjacent soft tissue change, and contrast enhancement of pannus. MRI detected not only 20 joints (SIJ 11, hip 9) detected in simple X-ray, but also additional 7 joints (SIJ 3, hip 4). MRI depicted simultaneous involvement of SIJ and hip joints in 5 of 11 cases (SIJ 10 joints, hip 9 joints), and bilateral involvement of SIJ and hip joints in 4 among the 5 cases. MRI also demonstrated pannus, which were not detected in conventional films, as intermediate SI on T1WI and high SI on T2WI, in all 27 joints (SIJ 14, hip 13). Gd-DTPA enhanced T1WI revealed enhancement of pannus in 7 cases (17 joints). MRI was a valuable modality in evaluation of clinically suspected ankylosing spondylitis of SIJ or hip joints with normal or minimal secondary bone change in simple X-ray. Simultaneous evaluation of SIJ and hip joints is suggested in clinically suspected ankylosing spondylitis or other joint diseases.

  11. Imaging of the temporomandibular joint: An update

    Institute of Scientific and Technical Information of China (English)

    Asim; K; Bag; Santhosh; Gaddikeri; Aparna; Singhal; Simms; Hardin; Benson; D; Tran; Josue; A; Medina; Joel; K; Curé

    2014-01-01

    Imaging of the temporomandibular joint(TMJ) is continuously evolving with advancement of imaging technologies. Many different imaging modalities are currently used to evaluate the TMJ. Magnetic resonance imaging is commonly used for evaluation of the TMJ due to its superior contrast resolution and its ability to acquire dynamic imaging for demonstration of the functionality of the joint. Computed tomography and ultrasound imaging have specific indication in imaging of the TMJ. This article focuses on state of the art imaging of the temporomandibular joint. Relevant normal anatomy and biomechanics of movement of the TMJ are discussed for better understanding of many TMJ pathologies. Imaging of internal derangements is discussed in detail. Different arthropathies and commontumors are also discussed in this article.

  12. Biomechanical evaluation of native acromioclavicular joint ligaments and two reconstruction techniques in the presence of the sternoclavicular joint: A cadaver study.

    Science.gov (United States)

    Masionis, Povilas; Šatkauskas, Igoris; Mikelevičius, Vytautas; Ryliškis, Sigitas; Bučinskas, Vytautas; Griškevičius, Julius; Martin Oliva, Xavier; Monzó Planella, Mariano; Porvaneckas, Narūnas; Uvarovas, Valentinas

    2017-01-01

    Where is over 100 reconstruction techniques described for acromioclavicular (AC) joint reconstruction. Although, it is not clear whether the presence of the sternoclavicular (SC) joint influences the biomechanical properties of native AC ligaments and reconstruction techniques. The purpose of the present study was to investigate the biomechanical properties of native AC joint ligaments and two reconstruction techniques in cadavers with the SC joint still present. We tested eight fresh-frozen cadaver hemithoraces for superior translation (70 N load) and translation increment after 1000 cycles (loading from 20 to 70 N) in a controlled laboratory study. There were three testing groups created: native ligaments, the single coracoclavicular loop (SCL) technique, and the two coracoclavicular loops (TCL) technique. Superior translation was measured after static loading. Translation increment was calculated as the difference between superior translation after cyclic and static loading. Native AC ligaments showed significantly lower translation than the SCL ( p = 0.023) and TCL ( p = 0.046) groups. The SCL had a significantly lower translation increment than native AC ligaments ( p = 0.028). There was no significant difference between reconstruction techniques in terms of translation ( p = 0.865) and translation increment ( p = 0.113). Native AC joint ligaments had better static properties than both reconstruction techniques and worse dynamic biomechanical properties than the SCL technique. The SCL technique appeared to be more secure than the TCL technique. The presence of the SC joint did not have an observable influence on test results.

  13. Evaluation of CT in the investigation of patellofemoral malalignment

    International Nuclear Information System (INIS)

    Zhang Quan; Huang Huangyuan; Xia Jun; Chen Wenjun

    1999-01-01

    Objective: To evaluate CT in investigating patellofemoral malalignment. Methods: CT was used to evaluate 32 patients (50 knees) with persistent patellofemoral pain and 15 asymptomatic volunteers (20 knees). Multiple mid-patellar images were obtained at 30 degree flexion. Results: Compared to controls, the patients had marked malalignment including three distinct patterns. 11 knees had lateral patellae based on high congruence angles (CA). 8 knees had tilted patellae with lower lateral patellofemoral angles (LPFA). 10 knees had both high CA and lower LPFA indicating both lateral and tilted patella. Conclusions: CT may be the optimal imaging method of evaluating the patellofemoral joint. An awareness of different patterns of malalignment is a significant advantage of CT when planning selective surgical realignment for these patients

  14. Career Commitment: Interplay of Core-Self-Evaluation and Reward ...

    African Journals Online (AJOL)

    This study investigated the joint influence of core self-evaluation (self efficacy, self-esteem, work locus of control and neuroticism) and reward system on carrer commitment of local government employees in Oyo State, Nigeria. The study adopted descriptive survey research design. A total of 2,040 respondents were selected ...

  15. Evaluation of mechanical properties of construction joint between new and old concrete under combined tensile and shear stresses; Shinkyu concrete no uchitsugime no incho sendan oryokuka no kyodo tokusei no hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Ujiike, I. [Ehime University, Ehime (Japan). Faculty of Engineering; Yoshida, N. [Shikoku Railway Company, Kagawa (Japan); Morishita, S. [Oriental Construction Co. Ltd., Tokyo (Japan)

    1998-01-15

    The objective of this study is to examine the mechanical properties of construction joints between existing and newly placed concrete under combined tensile and shear stresses. Loading tests are conducted by using push off type specimens. The joint surface of existing concrete is roughened by shot blast and a half of the specimen is reconstructed by new concrete using ultra rapid hardening cement. The insufficient treatment of joint surface of the old concrete causes the lowering of tensile rigidity, while shearing rigidity is almost the same as that of the other specimen. The shearing and tensile rigidities of non jointed concrete and concrete shot blasted properly are not dependent on the combination of shearing and tensile forces. For the jointed concrete shot blasted insufficiently, the shearing rigidity decreases with the increase of tensile force and the tensile digidity also becomes lower by the action of shearing force. Both the tensile strength and shearing strength of jointed concrete become small compared to those of non jointed concrete. The ratio of reduction in tensile strength is larger than that in shearing strength. The strength of jointed concrete under combined tensile and shear stresses can be evaluated by Mohr`s failure envelope expressed by parabola tangent to both tensile strength circle and compressive strength circle. 7 refs., 12 figs., 2 tabs.

  16. New tools for evaluating LQAS survey designs

    OpenAIRE

    Hund, Lauren

    2014-01-01

    Lot Quality Assurance Sampling (LQAS) surveys have become increasingly popular in global health care applications. Incorporating Bayesian ideas into LQAS survey design, such as using reasonable prior beliefs about the distribution of an indicator, can improve the selection of design parameters and decision rules. In this paper, a joint frequentist and Bayesian framework is proposed for evaluating LQAS classification accuracy and informing survey design parameters. Simple software tools are pr...

  17. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Science.gov (United States)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  18. Development of a new modeling technique of 3D S-wave velocity structure for strong ground motion evaluation - Integration of various geophysical and geological data using joint inversion

    International Nuclear Information System (INIS)

    Sugimoto, Yoshihiro

    2014-01-01

    A restricted stripe-like zone suffered major damage due to the 1995 Hyogo-ken Nanbu earthquake, and ground motion of the south side of the Kashiwazaki NPP site was much greater than that of the north side in the 2007 Niigata-ken Chuetsu-oki earthquake. One reason for these phenomena is thought to be the focusing effect due to irregularly shaped sedimentary basins (e.g., basin-edge structure, fold structure, etc.) This indicates that precise evaluation of S-wave velocity structure is important. A calculation program that was developed to make S-wave velocity models using the joint inversion method was presented. This program unifies various geophysical and geological data and can make a complex structure model for evaluating strong ground motion with high precision. (author)

  19. Effect of changes in the moisture content due to surrounding relative humidity on the contact stress in traditional mortise and tenon joints III : pull-out strength of compressed sugi komisen joints

    NARCIS (Netherlands)

    Jung, K.; Kitamori, A.; Leijten, A.J.M.; Komatsu, K.

    2006-01-01

    This research is focused on evaluating the efficiency and failure mechanism of joints using a komisen (Japanese traditional square key) of compressed sugi (Japanese ceder ;Cryptomeria japonica D. Don), and to evaluate to what extend hozo-komisen (Japanese traditional mortise and tenon) joint

  20. Evaluation of new composite rigid joint under cyclic loading and its effect on one-floor composite frame

    Directory of Open Access Journals (Sweden)

    Azadeh Haghighat

    2017-08-01

    Full Text Available In order to improve the performance of structure against lateral and gravity loads, new systems known as composite systems consisting of the reinforced concrete columns and steel beams (RCS can be used and thereby the advantages of concrete beside steel are acquired. RCS joints can be implemented as either through-beam-type joint or through-column-type joint. In this paper, a concrete joint as standard reference joint and a proposed composite joint through-column‎ with new details were built and tested under cyclic loading. Then, using numerical analysis by finite element method, the behavior of composite joint under cyclic loading has been studied and the behavior and performance of proposed composite joint has been studied by comparing the results with that of concrete joint. The results showed that the joint composition in this way resulted in decreasing of the compressive and tensile damages of concrete and increasing in loading capacity, ductility, stiffness and energy absorption. General results of application of composite joint at the one floor-one span composite frame indicating that lateral loading capacity of frame was increased and the performance of frame was improved.

  1. Entrepreneurship Education in the Arab States. Final Evaluation Report

    Science.gov (United States)

    Lamloumi, Jilani

    2013-01-01

    The report involves the findings of the final evaluation of the regional entrepreneurship education project in Arab States component II (2011-2012) (see ED560497), which is a joint activity between UNESCO and StratREAL Foundation. It aims to help the development of educational policies enabling the integration of entrepreneurship education within…

  2. Delivery of integrated diabetes care using logistics and information technology--the Joint Asia Diabetes Evaluation (JADE) program.

    Science.gov (United States)

    Chan, Juliana C N; Ozaki, Risa; Luk, Andrea; Kong, Alice P S; Ma, Ronald C W; Chow, Francis C C; Wong, Patrick; Wong, Rebecca; Chung, Harriet; Chiu, Cherry; Wolthers, Troels; Tong, Peter C Y; Ko, Gary T C; So, Wing-Yee; Lyubomirsky, Greg

    2014-12-01

    Diabetes is a global epidemic, and many affected individuals are undiagnosed, untreated, or uncontrolled. The silent and multi-system nature of diabetes and its complications, with complex care protocols, are often associated with omission of periodic assessments, clinical inertia, poor treatment compliance, and care fragmentation. These barriers at the system, patient, and care-provider levels have resulted in poor control of risk factors and under-usage of potentially life-saving medications such as statins and renin-angiotensin system inhibitors. However, in the clinical trial setting, use of nurses and protocol with frequent contact and regular monitoring have resulted in marked differences in event rates compared to epidemiological data collected in the real-world setting. The phenotypic heterogeneity and cognitive-psychological-behavioral needs of people with diabetes call for regular risk stratification to personalize care. Quality improvement initiatives targeted at patient education, task delegation, case management, and self-care promotion had the largest effect size in improving cardio-metabolic risk factors. The Joint Asia Diabetes Evaluation (JADE) program is an innovative care prototype that advocates a change in clinic setting and workflow, coordinated by a doctor-nurse team and augmented by a web-based portal, which incorporates care protocols and a validated risk engine to provide decision support and regular feedback. By using logistics and information technology, supported by a network of health-care professionals to provide integrated, holistic, and evidence-based care, the JADE Program aims to establish a high-quality regional diabetes database to reflect the status of diabetes care in real-world practice, confirm efficacy data, and identify unmet needs. Through collaborative efforts, we shall evaluate the feasibility, acceptability, and cost-effectiveness of this "high tech, soft touch" model to make diabetes and chronic disease care more

  3. Effect of the Shrink Fit and Mechanical Tolerance on Reactor Coolant Pump Flywheel Integrity Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Donghak [Korea KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Reactor coolant pump (RCP) flywheel should satisfy the RCP flywheel integrity criteria of the US NRC standard review plan (SRP) 5.4.1.1 and regulatory guide (RG) 1.14. Shrink-fit and rotational stresses should be calculated to evaluate the integrity. In this paper the effects of the shrink fit and mechanical tolerance on the RCP flywheel integrity evaluation are studied. The shrink fit should be determined by the joint release speed and the stresses in the flywheel will be increased by the shrink fit. The stress at the interface between the hub and the outer wheel shows the highest value. The effect of the mechanical tolerance should be considered for the stress evaluation. And the effect of the mechanical tolerance should be not considered to determine the joint release speed.

  4. Effect of the Shrink Fit and Mechanical Tolerance on Reactor Coolant Pump Flywheel Integrity Evaluation

    International Nuclear Information System (INIS)

    Kim, Donghak

    2015-01-01

    Reactor coolant pump (RCP) flywheel should satisfy the RCP flywheel integrity criteria of the US NRC standard review plan (SRP) 5.4.1.1 and regulatory guide (RG) 1.14. Shrink-fit and rotational stresses should be calculated to evaluate the integrity. In this paper the effects of the shrink fit and mechanical tolerance on the RCP flywheel integrity evaluation are studied. The shrink fit should be determined by the joint release speed and the stresses in the flywheel will be increased by the shrink fit. The stress at the interface between the hub and the outer wheel shows the highest value. The effect of the mechanical tolerance should be considered for the stress evaluation. And the effect of the mechanical tolerance should be not considered to determine the joint release speed

  5. Efficient diagnostic evaluation of fractures of the talus - an analysis based on examination of 40 patients

    International Nuclear Information System (INIS)

    Foerster, A.; Roehnert, W.; Koehler, K.

    1997-01-01

    Conventional radiography imaging the ankle joint in two planes is the initial technique applied, giving information on further diagnostic evaluation required. CT is of importance for such additional examination, and spiral CT in particular, as it can generate directly comparable pictures due to its standardised examination techniques. Joint surfaces are visualized without superpositions. Fractures and their numbers, dislocations as well as involvement of joint surfaces can be better detected. Also, spiral CT, due to the continuous data set generated, permits 2D reconstructions of high quality. 3D Reconstructions as a rule do not supply additional information. CT can be applied for diagnostic evaluation of the tendon and ligamentum system/soft tissue, but MRI will yield better results. (orig./CB) [de

  6. Evaluation of quantitative sacroiliac scintigraphy for the early detection of sacroiliitis

    International Nuclear Information System (INIS)

    Prakash, S.; Malaviya, A.N.; Gopinath, P.G.; Bhargava, S.; Mehra, N.K.

    1983-01-01

    Quantitative sacroliac scintigraphy (QSS) was evaluated for the detection of sacroiliac (SI) joint disease before the appearance of radiographic/changes. QSS with fractional quantitation was done in 13 age- and sexmatched controls and 28 patients with different grades of radiographic sacroliitis. The SI index of each joint was considered separately. The mean SI index values in patients with grade I radiographic sacroiliitis (1.54) and HLA-B27 positive patients with low back pain (1.50) were significantly (P 0.05). Thus a large overlap between the normal and abnormal ranges of sacroiliac ratios limits the utility of quantitative sacroiliac scintigraphy for the early diagnosis of sacroiliac joint disease. (orig.)

  7. Evaluation of chondromalacia in the knee joint using three dimensional Fourier transformation constructive interference in steady state (CISS)

    International Nuclear Information System (INIS)

    Yoon, Sam Hyun; Ha, Doo Hoe; Kwak, Jin Young; Lee, Young Soo

    2000-01-01

    To assess the usefulness of three-dimensional Fourier transformation constructive interference in steady state (CISS) for the evaluation of chondromalacia. In 110 knee joints which underwent both MR imaging and arthroscopy, the findings were retrospectively reviewed. MR imaging sequences included two-dimensional dual-echo turbo spin-echo imaging along the sagittal and coronal planes, two-dimensional fast low-angle shot (FLASH) with magnetization transfer along the axial plane, and three-dimensional CISS along the sagittal plane. After the cartilage surfaces of each joint were divided into eight areas (each medial and lateral area of patellar facets, trochlear surfaces, femoral condyles, and tibial plateaux), a total of 880 areas were assessed. Using both combined two-dimensional (2-D turbo spin-echo and FLASH) and CISS imaging during different sessions, each chondromalacia case was assigned one of five grades. Arthroscopy revealed the presence of chondromalacia in 162 areas. This was first grade in 77 areas, second grade in 38, third grade in 21, and fourth grade in 26. The sensitivity, specificity, and accuracy of 2-D and CISS imaging were 48.1%, 93.7% and 85.3%, and 45.7%, 95.3% and 86.1%, respectively. Agreement between MR and arthroscopic staging occurred in 81.48% of 2-D imaging procedures and 82.16% of CISS procedures. If a difference of one grade was accepted, these proportions rose to 84.32% and 85.22%, respectively, though this increase was statistically insignificant. Though CISS imaging was less sensitive than 2-D imaging in the grading of chondromalacia, additional CISS imaging can help improve the accuracy of this grading

  8. Evaluation of chondromalacia in the knee joint using three dimensional Fourier transformation constructive interference in steady state (CISS)

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sam Hyun; Ha, Doo Hoe; Kwak, Jin Young [College of Medicine, Pochon CHA University, Sungnam (Korea, Republic of); Lee, Young Soo [Pundang CHA General Hospital, College of Medicine, Pochon CHA University, Seoul (Korea, Republic of)

    2000-10-01

    To assess the usefulness of three-dimensional Fourier transformation constructive interference in steady state (CISS) for the evaluation of chondromalacia. In 110 knee joints which underwent both MR imaging and arthroscopy, the findings were retrospectively reviewed. MR imaging sequences included two-dimensional dual-echo turbo spin-echo imaging along the sagittal and coronal planes, two-dimensional fast low-angle shot (FLASH) with magnetization transfer along the axial plane, and three-dimensional CISS along the sagittal plane. After the cartilage surfaces of each joint were divided into eight areas (each medial and lateral area of patellar facets, trochlear surfaces, femoral condyles, and tibial plateaux), a total of 880 areas were assessed. Using both combined two-dimensional (2-D turbo spin-echo and FLASH) and CISS imaging during different sessions, each chondromalacia case was assigned one of five grades. Arthroscopy revealed the presence of chondromalacia in 162 areas. This was first grade in 77 areas, second grade in 38, third grade in 21, and fourth grade in 26. The sensitivity, specificity, and accuracy of 2-D and CISS imaging were 48.1%, 93.7% and 85.3%, and 45.7%, 95.3% and 86.1%, respectively. Agreement between MR and arthroscopic staging occurred in 81.48% of 2-D imaging procedures and 82.16% of CISS procedures. If a difference of one grade was accepted, these proportions rose to 84.32% and 85.22%, respectively, though this increase was statistically insignificant. Though CISS imaging was less sensitive than 2-D imaging in the grading of chondromalacia, additional CISS imaging can help improve the accuracy of this grading.

  9. Evaluation of the JISC Information Environment: student perceptions

    Directory of Open Access Journals (Sweden)

    Jillian R. Griffiths

    2003-01-01

    Full Text Available The Joint Information Systems Committee (JISC Information Environment (IE, a development from the DNER - Distributed National Electronic Resource, is intended to help users in the UK academic sector maximise the value of published information resources by developing a coherent environment out of the confusing array of systems and services currently available. The EDNER Project (Formative Evaluation of the DNER is funded to undertake ongoing evaluation of the developing IE over the full three years of the JISC 5/99 Learning & Teaching and Infrastructure Programme i.e. from 2000 to 2003. The EDNER Project is led by the Centre for Research in Library & Information Management (CERLIM at the Manchester Metropolitan University; the Centre for Studies in Advanced Learning Technologies (CSALT at Lancaster University is a partner. This paper reports on work in progress and some of the initial findings of the evaluation team.

  10. Application of Mixed Group Decision Making to Safety Evaluation of Agricultural Products

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    In view of the gravity of issues concerning safety of agricultural products and urgency of resolving these issues,after analyzing the problems existing in safety of agricultural products,this article offers a method for evaluating safety of agricultural products on the basis of mixed group decision making.First of all,it introduces the factors influencing safety evaluation of agricultural products;subsequently,given that the judgment matrices offered by the group of experts contain both reciprocal and complementary judgment matrices in the process of jointly participating in evaluation arising from personal preference,it proposes to assemble expert information in order to obtain indicator weight using the OWA operator;finally,the process of evaluating safety of agricultural products is given.

  11. Clinical and computerized evaluation in study of temporo-mandibular joint intracapsular disease.

    Science.gov (United States)

    Ciavarella, D; Mastrovincenzo, M; Sabatucci, A; Parziale, V; Granatelli, F; Violante, F; Bossù, M; Lo Muzio, L; Chimenti, C

    2010-03-01

    In this work authors show a diagnostic criteria in study of TMID: neuro occlusal clinical evaluation (NOE), T-Scan 2 system and surface electromyography (sEMG). Nine patients 25-30 years old with TMID problem and 9 healthy group control have been selected and examined. On each patients it has been performed NOE, T-Scan and sEMG test. NOE has been calculated on each patient photos lateral mandibular excursion angle called: masticatory functional angle (AFM). T-Scan System is a computerized occlusal analyzer that provide in-depth understanding of the overall balance of the occlusion. At the same time of T-Scan record sEMG tests, in resting position and in maximum clench, have been performed. In healthy control there were no AFM difference. In no healthy group there were difference between the two AFM greater than 6 degrees. T-Scan COF showed how in healthy group control there was never a difference of COF greater than 5%. In no healthy group the difference were greater than 5% Pjoint sound than the balance side P<0.001. sEMG show how in TMID patients maximum masseter activation is always lower than maximum masseter activation of healthy subjects P<0.001. Neuro occlusal clinical evaluation (NOE) in TMID patients is supported by instrumental evaluation.

  12. Joint Laxity in Preschool Children Born Preterm.

    Science.gov (United States)

    Romeo, Domenico M; Velli, Chiara; Lucibello, Simona; Ferrantini, Gloria; Leo, Giuseppina; Brogna, Claudia; Cota, Francesco; Ricci, Daniela; Gallini, Francesca; Romagnoli, Costantino; Vento, Giovanni; Mercuri, Eugenio

    2018-06-01

    To evaluate the prevalence of joint laxity in children born preterm assessed in the first 2 years, the relationship between joint laxity and motor performance at preschool age, and possible changes over time in a subgroup of children followed longitudinally. The revised scale of Beighton Score was used to evaluate joint laxity in a population of 132 preschool children born preterm between 24 and 32 weeks of gestational age. All were assessed for joint laxity between 12 and 24 months of age. Children also performed the Movement Assessment Battery for Children-Second Edition between the age of 3 years and 6 months and 4 years; the age at onset of independent walking also was recorded. The total Beighton Score ranged between 0 and 8. Twenty percent of the cohort showed joint laxity. No differences related to sex or gestational age were observed. Children born preterm with joint laxity achieved later independent walking and achieved lower scores on Movement Assessment Battery for Children-Second Edition than those without joint laxity. In 76 children born preterm, an assessment for joint laxity was repeated once between 25 and 36 months and again after >36 months. No statistically significant difference was observed between the 3 assessments. The Beighton Score can be used to assess generalized joint laxity in children born preterm. As the presence of joint laxity influenced motor competences, the possibility to early identify these infants in the first 2 years is of interest to benefit from early intervention and potentially improve gross motor skills and coordination. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Phenotypic and genetic evaluation of elbow dysplasia in Dutch Labrador Retrievers, Golden Retrievers, and Bernese Mountain Dogs

    NARCIS (Netherlands)

    Lavrijsen, I.C.M.; Heuven, H.C.M.; Voorhout, G.; Meij, B.P.; Theyse, L.F.H.; Leegwater, P.A.J.; Hazewinkel, H.A.W.

    2012-01-01

    Canine elbow dysplasia encompasses four developmental diseases: ununited anconeal process, osteochondrosis of the medial part of the humeral condyle, fragmented medial coronoid process (FCP), and incongruity of the elbow joint. Four radiographic views per joint were used to evaluate 2693 Labrador

  14. Multinuclide digital subtraction imaging in symptomatic prostnetic joints

    International Nuclear Information System (INIS)

    Chafetz, N.; Hattner, R.S.; Ruarke, W.C.; Helms, C.A.; Genant, H.K.; Murray, W.R.

    1985-01-01

    One hundred eleven patients with symptomatic prosthetic joints (86 hips, 23 knees, and two shoulders) were evaluated for prosthetic loosening and infection by combined technetium-99m-MDP/gallium-67 digital subtraction imaging. Clinical correlation was based on the assessment of loosening and bacterial cultures obtained at the time of surgery in 54 patients, joint aspiration cultures obtained in 37 patients, and long-term clinical follow-up for greater than 1.5 years in an additional 15 patients. Results revealed an 80-90% predictive value of a positive test for loosening, and a 95% predictive value of a negative test for infection. However, because of the low sensitivities and specificities observed, this approach to the evaluation of symptomatic prosthetic joints does not seem cost effective

  15. The effects of transcutaneous electrical nerve stimulation on joint position sense in patients with knee joint osteoarthritis.

    Science.gov (United States)

    Shirazi, Zahra Rojhani; Shafaee, Razieh; Abbasi, Leila

    2014-10-01

    To study the effects of transcutaneous electrical nerve stimulation (TENS) on joint position sense (JPS) in knee osteoarthritis (OA) subjects. Thirty subjects with knee OA (40-60 years old) using non-random sampling participated in this study. In order to evaluate the absolute error of repositioning of the knee joint, Qualysis Track Manager system was used and sensory electrical stimulation was applied through the TENS device. The mean errors in repositioning of the joint, in two position of the knee joint with 20 and 60 degree angle, after applying the TENS was significantly decreased (p knee OA could improve JPS in these subjects.

  16. Evaluating the Relationship between Team Performance and Joint Attention with Longitudinal Multivariate Mixed Models

    Science.gov (United States)

    2016-09-23

    Sweller, J. (2005). Cognitive load theory and complex learning: Recent developments and future directions. Educational Psychology Review, 17(2), 147–177...Relationship between Team Performance and Joint Attention with Longitudinal Multivariate Mixed Models 5a. CONTRACT NUMBER FA8650-14-D-6501-0009 5b...Annual Meeting, 19-23 September 2016. 14. Previous research indicates that measures of joint attention provide unique insight into team cognition

  17. EVALUATION OF COURSE EVALUATIONS

    DEFF Research Database (Denmark)

    Friis-Hansen, Peter; Houbak, Niels; Klit, Peder

    2005-01-01

    and we have seen excellent lectures obtaining poor evaluations due to circumstances out of their control. On the other hand, with the analysis at hand, it is much easier to focus on specific needs for improvements. The effect of ‘chasing the bad performance’ over the past few years will be shown....... have for more than 10 years been evaluating the courses they attend. During the last 5 years, this evaluation has been electronic as an integral part of our CampusNet computing and course admini¬stra¬tion system. At the MEK department we have a committee in charge of our educational activities. One...... obligation is – two times a year – to go through in detail the evaluations for each of our 100+ courses and for each of the 50+ teachers. A rather tedious job, where the outcome seldom justifies the resources spent. The electronic version has opened up for further analysis of the evaluation data...

  18. Safety evaluation of food flavorings

    International Nuclear Information System (INIS)

    Schrankel, Kenneth R.

    2004-01-01

    Food flavorings are an essential element in foods. Flavorings are a unique class of food ingredients and excluded from the legislative definition of a food additive because they are regulated by flavor legislation and not food additive legislation. Flavoring ingredients naturally present in foods, have simple chemical structures, low toxicity, and are used in very low levels in foods and beverages resulting in very low levels of human exposure or consumption. Today, the overwhelming regulatory trend is a positive list of flavoring substances, e.g. substances not listed are prohibited. Flavoring substances are added to the list following a safety evaluation based on the conditions of intended use by qualified experts. The basic principles for assessing the safety of flavoring ingredients will be discussed with emphasis on the safety evaluation of flavoring ingredients by the Food and Agriculture Organization (FAO) and World Health Organization (WHO) Joint Expert Committee on Food Additives (JECFA) and the US Flavor and Extract Manufacturers Expert Panel (FEXPAN). The main components of the JECFA evaluation process include chemical structure, human intake (exposure), metabolism to innocuous or harmless substances, and toxicity concerns consistent with JECFA principles. The Flavor and Extract Manufacturers Association (FEMA) evaluation is very similar to the JECFA procedure. Both the JECFA and FEMA evaluation procedures are widely recognized and the results are accepted by many countries. This implies that there is no need for developing countries to conduct their own toxicological assessment of flavoring ingredients unless it is an unique ingredient in one country, but it is helpful to survey intake or exposure assessment. The global safety program established by the International Organization of Flavor Industry (IOFI) resulting in one worldwide open positive list of flavoring substances will be reviewed

  19. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    Science.gov (United States)

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Immediate effects of a new microprocessor-controlled prosthetic knee joint: a comparative biomechanical evaluation.

    Science.gov (United States)

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-03-01

    To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and

  1. Student Evaluation of Teaching: An Instrument and a Development Process

    Science.gov (United States)

    Alok, Kumar

    2011-01-01

    This article describes the process of faculty-led development of a student evaluation of teaching instrument at Centurion School of Rural Enterprise Management, a management institute in India. The instrument was to focus on teacher behaviors that students get an opportunity to observe. Teachers and students jointly contributed a number of…

  2. Evaluation of selected trace metals in some hypertensive subjects in ...

    African Journals Online (AJOL)

    Both patients and control subjects were classified based on the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7). The weight, height and blood pressure of all subjects were measured and their body mass indices (BMI) computed. The mean ...

  3. Fatigue behaviour of friction welded medium carbon steel and austenitic stainless steel dissimilar joints

    International Nuclear Information System (INIS)

    Paventhan, R.; Lakshminarayanan, P.R.; Balasubramanian, V.

    2011-01-01

    Research highlights: → Fusion welding of dissimilar metals is a problem due to difference in properties. → Solid state welding process such as friction welding is a solution for the above problem. → Fatigue life of friction welded carbon steel and stainless steel joints are evaluated. → Effect of notch on the fatigue life of friction welded dissimilar joints is reported. → Formation of intermetallic is responsible for reduction in fatigue life of dissimilar joints. -- Abstract: This paper reports the fatigue behaviour of friction welded medium carbon steel-austenitic stainless steel (MCS-ASS) dissimilar joints. Commercial grade medium carbon steel rods of 12 mm diameter and AISI 304 grade austenitic stainless steel rods of 12 mm diameter were used to fabricate the joints. A constant speed, continuous drive friction welding machine was used to fabricate the joints. Fatigue life of the joints was evaluated conducting the experiments using rotary bending fatigue testing machine (R = -1). Applied stress vs. number of cycles to failure (S-N) curve was plotted for unnotched and notched specimens. Basquin constants, fatigue strength, fatigue notch factor and notch sensitivity factor were evaluated for the dissimilar joints. Fatigue strength of the joints is correlated with microstructure, microhardness and tensile properties of the joints.

  4. Nuclear data evaluation and group constant generation for reactor analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Do; Gil, Choong Sup [Korea Atomic Energy Res. Inst., Taejon (Korea, Republic of)

    1993-12-01

    In nuclear or shielding design analysis for reactors including nuclear facilities, nuclear data are one of the primary importances. Research project for nuclear data evaluation and their effective applications has been continuously performed. The objectives of this project are (1) to compile the latest evaluated nuclear data files, (2) to establish their processing code systems, and (3) to evaluate the multigroup constant library using the newly compiled data files and the code systems. As the results of this project, JEF-2.2 which is latest version of Joint Evaluated File developed at OECD/NEA was compiled and COMPLOT and EVALPLOT utility codes were installed in personal computer, which are able to draw ENDF/B-formatted nuclear data for comparison and check. Computer system (NJOY/ACER) for generating continuous energy Monte Carlo code MCNP library was established and the system was validated by analyzing a number of experimental data. (Author).

  5. Study on evaluation methods for Rayleigh wave dispersion characteristic

    Science.gov (United States)

    Shi, L.; Tao, X.; Kayen, R.; Shi, H.; Yan, S.

    2005-01-01

    The evaluation of Rayleigh wave dispersion characteristic is the key step for detecting S-wave velocity structure. By comparing the dispersion curves directly with the spectra analysis of surface waves (SASW) method, rather than comparing the S-wave velocity structure, the validity and precision of microtremor-array method (MAM) can be evaluated more objectively. The results from the China - US joint surface wave investigation in 26 sites in Tangshan, China, show that the MAM has the same precision with SASW method in 83% of the 26 sites. The MAM is valid for Rayleigh wave dispersion characteristic testing and has great application potentiality for site S-wave velocity structure detection.

  6. Statistical evaluation of design-error related nuclear reactor accidents

    International Nuclear Information System (INIS)

    Ott, K.O.; Marchaterre, J.F.

    1981-01-01

    In this paper, general methodology for the statistical evaluation of design-error related accidents is proposed that can be applied to a variety of systems that evolves during the development of large-scale technologies. The evaluation aims at an estimate of the combined ''residual'' frequency of yet unknown types of accidents ''lurking'' in a certain technological system. A special categorization in incidents and accidents is introduced to define the events that should be jointly analyzed. The resulting formalism is applied to the development of U.S. nuclear power reactor technology, considering serious accidents (category 2 events) that involved, in the accident progression, a particular design inadequacy. 9 refs

  7. Elbow joint stability in relation to forced external rotation

    DEFF Research Database (Denmark)

    Deutch, S.R.; Jensen, S.L.; Olsen, B.S.

    2003-01-01

    The objective of this study was to evaluate the osseous constraint related to forced forearm external rotation as the initial stage in a posterior elbow dislocation. Six joint specimens without soft tissues were examined in a joint analysis system developed for simulation of dislocation. The osse......The objective of this study was to evaluate the osseous constraint related to forced forearm external rotation as the initial stage in a posterior elbow dislocation. Six joint specimens without soft tissues were examined in a joint analysis system developed for simulation of dislocation...... external forearm rotation until the point of maximal torque decreased from a maximum in full extension to a minimum at 30 degrees of elbow flexion (P =.03). The elbow in a slightly flexed position, varus stress, and forearm external rotation trauma might be the important biomechanical factors...

  8. Joint imaging

    International Nuclear Information System (INIS)

    Hengst, W.

    1984-01-01

    Joint imaging is a proven diagnostic procedure which has become indispensable to the detection and treatment of different joint diseases in almost all disciplines. The method is suited for early diagnosis of joint affections both in soft tissue and bone which cannot be detected by X-ray or other procedures. The local activity accumulation depends on the rate of metabolism and is visualized in the scan, which in turn enables the extension and floridity of focal lesions to be evaluated and followed-up. Although joint scans may often give hints to probabilities relevant to differential diagnosis, the method is non-specific and only useful if based on the underlying clinical picture and X-ray finding, if possible. The radiation exposure is very low and does not represent a hazard in cases of adequate assessment of indication. In pregnant women and children the assessment of indication has to be based on very strict principles. The method is suited for out-patient diagnosis and can be applied in all installations equipped with a gamma camera and a technetium generator. (orig.) [de

  9. Characteristics of welded joints of nuclear reactor interest

    International Nuclear Information System (INIS)

    1978-01-01

    The main propose of this work, was the determination of the optical conditions for obtaining welded joints of stainless steel, the quality control of joints obtained by destructive and non-destructive essays, as well as, the first specific essays of fluence and fatigue of the base metals employed. All tests performed in the base metals are very important from the joint of view that the comparison between results obtained with base metals and welded joints allows a the evaluation of the efficiency of the welded joints. (author) [pt

  10. Long-term clinical evaluation of the automatic stance-phase lock-controlled prosthetic knee joint in young adults with unilateral above-knee amputation.

    Science.gov (United States)

    Andrysek, Jan; Wright, F Virginia; Rotter, Karin; Garcia, Daniela; Valdebenito, Rebeca; Mitchell, Carlos Alvarez; Rozbaczylo, Claudio; Cubillos, Rafael

    2017-05-01

    The purpose of this study was to clinically evaluate the automatic stance-phase lock (ASPL) knee mechanism against participants' existing weight-activated braking (WAB) prosthetic knee joint. This prospective crossover study involved 10 young adults with an above-knee amputation. Primary measurements consisted of tests of walking speeds and capacity. Heart rate was measured during the six-minute walk test and the Physiological Cost Index (PCI) which was calculated from heart rate estimated energy expenditure. Activity was measured with a pedometer. User function and quality of life were assessed using the Lower Limb Function Questionnaire (LLFQ) and Prosthetic Evaluation Questionnaire (PEQ). Long-term follow-up over 12 months were completed. Walking speeds were the same for WAB and APSL knees. Energy expenditure (PCI) was lower for the ASPL knees (p = 0.007). Step counts were the same for both knees, and questionnaires indicated ASPL knee preference attributed primarily to knee stability and improved walking, while limitations included terminal impact noise. Nine of 10 participants chose to keep using the ASPL knee as part of the long-term follow-up. Potential benefits of the ASPL knee were identified in this study by functional measures, questionnaires and user feedback, but not changes in activity or the PEQ.

  11. An Evaluation of Joint and Service-Specific Advertising Efficiency for Military Recruitment

    National Research Council Canada - National Science Library

    Kwinn, Michael

    2000-01-01

    ... (Army, Navy, Air Force, Marines). This is done using data gathered in 1984 under the Department of Defense sponsored 'Advertising Mix Test' wherein a designed experiment varied the levels of joint and service-specific advertising across the U.S...

  12. Development and Evaluation of a Responsive Building Envelope

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Foged, Isak Worre

    2011-01-01

    . The general scopes of this paper are to present the development and evaluation of a new adaptive kinetic architectural structure. This reconfigurable structure can transform body shape from planar geometries to hyper-surfaces using different control strategies, i.e. a transformation into more than one or two...... of a secondary environmental system to a primary structural system joint into a collective behavioural system equipment with an actuator system is presented....

  13. EFSA EFSA ; Scientific Opinion on Flavouring Group Evaluation 99 (FGE.99): Consideration of furanone derivatives evaluated by the JECFA (63rd, 65th and 69th meetings)

    DEFF Research Database (Denmark)

    Larsen, John Christian; Nørby, Karin Kristiane; Beltoft, Vibe Meister

    The Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids of the European Food Safety Authority was requested to consider evaluations of flavouring substances assessed since 2000 by the Joint FAO/WHO Expert Committee on Food Additives (the JECFA), and to decide whether further...

  14. Qualitative evaluations and comparisons of six night-vision colorization methods

    Science.gov (United States)

    Zheng, Yufeng; Reese, Kristopher; Blasch, Erik; McManamon, Paul

    2013-05-01

    Current multispectral night vision (NV) colorization techniques can manipulate images to produce colorized images that closely resemble natural scenes. The colorized NV images can enhance human perception by improving observer object classification and reaction times especially for low light conditions. This paper focuses on the qualitative (subjective) evaluations and comparisons of six NV colorization methods. The multispectral images include visible (Red-Green- Blue), near infrared (NIR), and long wave infrared (LWIR) images. The six colorization methods are channel-based color fusion (CBCF), statistic matching (SM), histogram matching (HM), joint-histogram matching (JHM), statistic matching then joint-histogram matching (SM-JHM), and the lookup table (LUT). Four categries of quality measurements are used for the qualitative evaluations, which are contrast, detail, colorfulness, and overall quality. The score of each measurement is rated from 1 to 3 scale to represent low, average, and high quality, respectively. Specifically, high contrast (of rated score 3) means an adequate level of brightness and contrast. The high detail represents high clarity of detailed contents while maintaining low artifacts. The high colorfulness preserves more natural colors (i.e., closely resembles the daylight image). Overall quality is determined from the NV image compared to the reference image. Nine sets of multispectral NV images were used in our experiments. For each set, the six colorized NV images (produced from NIR and LWIR images) are concurrently presented to users along with the reference color (RGB) image (taken at daytime). A total of 67 subjects passed a screening test ("Ishihara Color Blindness Test") and were asked to evaluate the 9-set colorized images. The experimental results showed the quality order of colorization methods from the best to the worst: CBCF colorization and for quantitative evaluation using an objective metric such as objective evaluation index

  15. Dimensioning and efficiency evaluation of hybrid solar systems for energy production

    Directory of Open Access Journals (Sweden)

    Elia Stefano

    2008-01-01

    Full Text Available Nowadays hybrid panels for joint production of thermal and electrical energy are available on the market. The main contribution of this work is to evaluate the performances of hybrid systems and to determine the field of application. Mathematical models of panels are considered to evaluate thermal and electrical behavior of the problem. A software produced by the authors is shown that calculates the energy production of these devices in several operating situations; a comparison to that of photovoltaic and thermal systems is performed. Moreover, the economic validity of a such investment is evaluated. Finally a simplified criterion has been developed to calculate the best subdivision of the available deployment surface among thermal, photovoltaic, and hybrid panels.

  16. Shoulder impingement syndrome : evaluation of the causes with MRI

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Ho; Song, In Sup; Chung, Hun Young; Yoon, Sang Jin; Kim, Yang Soo; Shim, Hyung Jin; Choi, Young Hee; Lee, Jong Beum; Lee, Yong Chul; Kim, Kun Sang [Chungang Univ. College of Medicine, Seoul (Korea, Republic of); Choi, Yun Sun [Eulji Hospital, College of Medicine, Seoul (Korea, Republic of)

    1999-12-01

    Various mechanical causes which induce shoulder impingement syndrome have been identified with the help of MRI. The aim of this study is to evaluate the incidence of such causes. A total of 54 patients with clinically confirmed shoulder impingement syndrome and a normal control group(n=20) without symptoms were included. We evaluated the incidence of hook shaped acromion, low lying acromion, downward slope of the acromion, subacromial spur, acromioclavicular joint hypertrophy, coracoacromial ligament hypertrophy, high cuff muscle bulk, and os acromiale. Among the 54 patients, the following conditions were present: acromioclavicular joint hypertrophy(n=36), coracoacromial ligament hypertrophy(n=20), subacromial spur(n=18), downward sloping of the acromion(n=16), hook shaped acromion(n=11), relatively high cuff muscle bulk(n=6), low lying acromion relative to the clavicle(n=3), and os acromiale(n=1). In the normal control group there were nine cases of acromioclavicular joint hypertrophy, nine of coracoacromial ligament hypertrophy, nine of downward sloping acromion, and three of low lying acromion, but hook shaped acromion, high cuff muscle bulk, and os acromiale were not found. Among 54 patients, the syndrome was due to five simultancous causes in one patient, four causes in two, three causes in 12, two causes in 22, and one cause in 17. Hook shaped acromion and subacromial spur are the statistically significant causes of shoulder impingement syndrome. In 69% of patients, the condition was due to more than one cause.

  17. Shoulder impingement syndrome : evaluation of the causes with MRI

    International Nuclear Information System (INIS)

    Choi, Yong Ho; Song, In Sup; Chung, Hun Young; Yoon, Sang Jin; Kim, Yang Soo; Shim, Hyung Jin; Choi, Young Hee; Lee, Jong Beum; Lee, Yong Chul; Kim, Kun Sang; Choi, Yun Sun

    1999-01-01

    Various mechanical causes which induce shoulder impingement syndrome have been identified with the help of MRI. The aim of this study is to evaluate the incidence of such causes. A total of 54 patients with clinically confirmed shoulder impingement syndrome and a normal control group(n=20) without symptoms were included. We evaluated the incidence of hook shaped acromion, low lying acromion, downward slope of the acromion, subacromial spur, acromioclavicular joint hypertrophy, coracoacromial ligament hypertrophy, high cuff muscle bulk, and os acromiale. Among the 54 patients, the following conditions were present: acromioclavicular joint hypertrophy(n=36), coracoacromial ligament hypertrophy(n=20), subacromial spur(n=18), downward sloping of the acromion(n=16), hook shaped acromion(n=11), relatively high cuff muscle bulk(n=6), low lying acromion relative to the clavicle(n=3), and os acromiale(n=1). In the normal control group there were nine cases of acromioclavicular joint hypertrophy, nine of coracoacromial ligament hypertrophy, nine of downward sloping acromion, and three of low lying acromion, but hook shaped acromion, high cuff muscle bulk, and os acromiale were not found. Among 54 patients, the syndrome was due to five simultancous causes in one patient, four causes in two, three causes in 12, two causes in 22, and one cause in 17. Hook shaped acromion and subacromial spur are the statistically significant causes of shoulder impingement syndrome. In 69% of patients, the condition was due to more than one cause

  18. Evaluation model applied to TRANSPETRO's Marine Terminals Standardization Program

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de; Mueller, Gabriela [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Garcia, Luciano Maldonado [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes an innovative evaluation model applied to TRANSPETRO's 'Marine Terminals Standardization Program' based on updating approaches of programs evaluation and organizational learning. Since the program was launched in 2004, the need for having an evaluation model able to evaluate its implementation progress, to measure the degree of standards compliance and its potential economic, social and environmental impacts has become evident. Within a vision of safe and environmentally responsible operations of marine terminals, this evaluation model was jointly designed by TRANSPETRO and PUC-Rio to promote continuous improvement and learning in operational practices and in the standardization process itself. TRANSPETRO believes that standardization supports its services and management innovation capability by creating objective and internationally recognized parameters, targets and metrology for its business activities. The conceptual model and application guidelines for this important tool are presented in this paper, as well as the next steps towards its implementation. (author)

  19. An evaluation method on seat comfort based on optical motion capture

    Directory of Open Access Journals (Sweden)

    Qing TAO

    2015-10-01

    Full Text Available To research the sitting posture comfort evaluation method, through the example of comfort evaluation of the ergonomic seat and standard office seat, a methodology is introduced to evaluate the sitting posture comfort combining ergonomics theory. The proposed method is based on optical motion capture system, pressure sensor and JACK software, and TRC file is acquired by using EVART real-time capture software for identifying the spatial motion trail of human body. Then MATLAB software is used to analyze the human body motion data, and the sitting posture angle difference data for human body in different seats is acquired. TRC file is loaded into JACK software, and with the TAT REPORTER of JACK software, muscle force, moment of force and fatigue data, etc. are output, which are compared with the actual measured data from experiments, and ergonomics method is used for the evaluation. The result shows that the method of considering joint angles combining JACK software for data output is effective for evaluating sitting comfort.

  20. Synovial Lipoma of the Subtalar Joint.

    Science.gov (United States)

    Whitaker, Jeffrey M; Richards, Sarah; LeCastre, Michael J; Hooke, Thomas G

    2017-07-01

    Lipomas are benign adipose masses that are rarely associated with synovial membranes. In addition, there are only a few reports describing synovial lipomas in the foot. No reported occurrence of this lesion in the subtalar joint currently exists. This case report documents the presentation, clinical evaluation, advanced imaging, and surgical management of a 45-year-old man with a large synovial lipoma of the subtalar joint.

  1. Analysis of NSTX TF Joint Voltage Measurements

    International Nuclear Information System (INIS)

    Woolley R

    2005-01-01

    This report presents findings of analyses of recorded current and voltage data associated with 72 electrical joints operating at high current and high mechanical stress. The analysis goal was to characterize the mechanical behavior of each joint and thus evaluate its mechanical supports. The joints are part of the toroidal field (TF) magnet system of the National Spherical Torus Experiment (NSTX) pulsed plasma device operating at the Princeton Plasma Physics Laboratory (PPPL). Since there is not sufficient space near the joints for much traditional mechanical instrumentation, small voltage probes were installed on each joint and their voltage monitoring waveforms have been recorded on sampling digitizers during each NSTX ''shot''

  2. US/Russian Joint Film Test

    Science.gov (United States)

    Slater, Richard

    1996-01-01

    A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia's Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and an evaluation of the test data by the RKK Energia. ISC's evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.

  3. Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CT (μCT) evaluation of the temporomandibular joint (TMJ) condylar morphology

    Energy Technology Data Exchange (ETDEWEB)

    Geiger, Daniel [Sapienza University of Rome, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B. [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2014-01-15

    Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. The purpose of this study was to determine the accuracy of novel 3D-UTE MRI versus micro-CT (μCT) for quantitative evaluation of mandibular condyle morphology. Nine TMJ condyle specimens were harvested from cadavers (2 M, 3 F; age 85 ± 10 years, mean ± SD). 3D-UTE MRI (TR = 50 ms, TE = 0.05 ms, 104-μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18-μm isotropic-voxel) was also performed. MR datasets were spatially registered with a μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on the MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions, and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature, and segmented volume of the bone were determined using intraclass correlation coefficient (ICC) analysis. Between MRI and μCT, the average deviation of surface coordinates was 0.19 ± 0.15 mm, slightly higher than the spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7 ± 6.5 % and 6.6 ± 6.2 %, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature, and segmented volumes were 0.892, 0.893, and 0.972, respectively. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999, and 0.997, respectively. Fibrocartilage thickness was 0.55 ± 0.11 mm, as previously described in the literature for grossly normal TMJ samples. 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature, and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  4. Establishing a Research and Evaluation Capability for the Joint Medical Education and Training Campus

    OpenAIRE

    Kirby, Sheila Nataraj; Marsh, Julie A.; Thie, Harry J.

    2011-01-01

    In calling for the transformation of military medical education and training, the 2005 Base Realignment and Closure Commission recommended relocating basic and specialty enlisted medical training to a single site to take advantage of economies of scale and the opportunity for joint training. As a result, a joint medical education and training campus (METC) has been established at Fort Sam Houston, Texas. Two of METC's primary long-term goals are to become a high-performing learning organizati...

  5. Models of evaluation of public joint-stock property management

    Science.gov (United States)

    Yakupova, N. M.; Levachkova, S.; Absalyamova, S. G.; Kvon, G.

    2017-12-01

    The paper deals with the models of evaluation of performance of both the management company and the individual subsidiaries on the basis of a combination of elements and multi-parameter and target approaches. The article shows that due to the power of multi-dimensional and multi-directional indicators of financial and economic activity it is necessary to assess the degree of achievement of the objectives with the use of multivariate ordinal model as a set of indicators, ordered by growth so that the maintenance of this order on a long interval of time will ensure the effective functioning of the enterprise in the long term. It is shown that these models can be regarded as the monitoring tools of implementation of strategies and guide the justification effectiveness of implementation of management decisions.

  6. Visual soil evaluation and soil compaction research

    DEFF Research Database (Denmark)

    M.L. Guimarães, Rachel; Keller, Thomas; Munkholm, Lars Juhl

    2017-01-01

    Following on from discussions that took place during the 19th International Conference of the International Soil Tillage Research Organization (ISTRO) in Montevideo, Uruguay, in 2012, the ISTRO working groups “Visual Soil Examination and Evaluation” (VSEE) and “Subsoil Compaction” decided...... to organize a joint workshop. The present special issue is an outcome from the workshop on “Soil structural quality of tropical soils: Visual evaluation methods and soil compaction prevention strategies” that was held 26–29 May 2014 in Maringá, Paraná, Brazil. There has been a long-lasting interest in Visual...... Soil Evaluation (VSE). An ISTRO working group was established more than 30 years ago with the objectives to exchange knowledge and experiences on field methods of visual-tactile soil assessment and to foster international cooperation on new or refined methods. The three previous meeting of the group...

  7. Evaluation of weld joints properties of 60mm thick AISI 316L for fusion reactor vacuum vessel by TIG and EB welding processes

    International Nuclear Information System (INIS)

    Buddu, Ramesh Kutner

    2016-01-01

    The present paper is focussed on the NDT examination procedures, evaluated mechanical properties; microstructure details investigated on the different welding process of Multipass TIG process (64 passes) and electron beam welding (two pass) of the AISI SS316LN plates. The characterization of mechanical properties (Tensile, Bend, Hardness and Impact) and detailed microstructure analysis have been discussed in this paper. Mechanical properties in both conditions shown higher joint efficiencies. Bend tests shown the good quality of weld and ductility behavior of the joining process. Hardening is observed in both the samples for welded zone and HAZ compared to base metal. Impact fracture results revealed the poor toughness properties for the WZ compared to HAZ and BM samples in both the cases

  8. Accident prediction models for rural junctions on four European countries. Road Infrastructure Safety Management Evaluation Tools (RISMET), Deliverable No. 6.1.

    NARCIS (Netherlands)

    Azeredo Lopes, S. de & Lourenço Cardoso, J.

    2014-01-01

    The "Road Infrastructure Safety Management Evaluation Tools (RISMET)" project targets objective A (Development of evaluation tools) of the Joint Call for Proposals for Safety at the Heart of Road Design ("The Call"). This project aims at developing suitable road safety engineering evaluation tools

  9. Evaluated Data Projects at the NEA

    International Nuclear Information System (INIS)

    Henriksson, H.; Rugama, Y.

    2006-01-01

    The OECD Nuclear Energy Agency (NEA) Data Bank is part of an international network of data centres in charge of the compilation and dissemination of basic nuclear data. The NEA offers easy access to the main nuclear databases with bibliographical information, evaluated libraries, e.g. the Joint Evaluated Fission and Fusion (JEFF) library, and experimental data in the EXFOR database, comprising published neutron induced as well as charged particle induced nuclear reaction data. The NEA Working Party on international nuclear data Evaluation Co-operation (WPEC) is established to promote the exchange of information on nuclear data evaluations, measurements, nuclear model calculations and validation. WPEC provides a framework for co-operative activities between six major evaluation projects (BROND, CENDL, Endf, FENDL, JEFF and JENDL). The NEA Data Bank administrates the collection and validation as well as the distribution of the JEFF library. The latest version, JEFF-3.1, was released in May 2005 and it contains a neutron data library, a proton data library and thermal scattering law data. The special purpose library on activation data contains 774 nuclei with over 12600 neutron induced reactions. Included is also radioactive decay data, with 3852 isotopes, and spontaneous and neutron induced fission yield data. The full documentation of the library is being prepared for publication in 2006. Processed JEFF-3.1 data files in ACE format, mainly for reactor physics applications, have been prepared and were distributed in spring 2006 with documentation. The processed files have been validated for criticality calculations, as well as for radiation physics application. The detailed analysis of the validation results will be very useful for improving the accuracy of evaluated data libraries. The display program JANIS has been developed at the NEA, and the latest version (JANIS-2.21) was released in October 2005. JANIS is designed to facilitate the visualisation and

  10. "Efficiency Space" - A Framework for Evaluating Joint Evaporation and Runoff Behavior

    Science.gov (United States)

    Koster, Randal

    2014-01-01

    At the land surface, higher soil moisture levels generally lead to both increased evaporation for a given amount of incoming radiation (increased evaporation efficiency) and increased runoff for a given amount of precipitation (increased runoff efficiency). Evaporation efficiency and runoff efficiency can thus be said to vary with each other, motivating the development of a unique hydroclimatic analysis framework. Using a simple water balance model fitted, in different experiments, with a wide variety of functional forms for evaporation and runoff efficiency, we transform net radiation and precipitation fields into fields of streamflow that can be directly evaluated against observations. The optimal combination of the functional forms the combination that produces the most skillful stream-flow simulations provides an indication for how evaporation and runoff efficiencies vary with each other in nature, a relationship that can be said to define the overall character of land surface hydrological processes, at least to first order. The inferred optimal relationship is represented herein as a curve in efficiency space and should be valuable for the evaluation and development of GCM-based land surface models, which by this measure are often found to be suboptimal.

  11. An evaluation of the carrying angle of the elbow joint in adolescents

    African Journals Online (AJOL)

    McRoy

    Department of Anatomy and Orthopedics, Sri Lakshmi Narayana Institute of Medical Sciences,. Pondicherry - 605 502 ... forearm deviates laterally from the long axis of the humerus, with the arm extended and the palm ... for elbow reconstruction. Key words: Carrying angle, elbow joint, adolescent, forearm, humerus, ulna ...

  12. Improvement and evaluation of thermal, electrical, sealing and mechanical contacts, and their interface materials

    Science.gov (United States)

    Luo, Xiangcheng

    Material contacts, including thermal, electrical, seating (fluid sealing and electromagnetic sealing) and mechanical (pressure) contacts, together with their interface materials, were, evaluated, and in some cases, improved beyond the state of the art. The evaluation involved the use of thermal, electrical and mechanical methods. For thermal contacts, this work evaluated and improved the heat transfer efficiency between two contacting components by developing various thermal interface pastes. Sodium silicate based thermal pastes (with boron nitride particles as the thermally conductive filler) as well as polyethylene glycol (PEG) based thermal pastes were developed and evaluated. The optimum volume fractions of BN in sodium silicate based pastes and PEG based pastes were 16% and 18% respectively. The contribution of Li+ ions to the thermal contact conductance in the PEG-based paste was confirmed. For electrical contacts, the relationship between the mechanical reliability and electrical reliability of solder/copper and silver-epoxy/copper joints was addressed. Mechanical pull-out testing was conducted on solder/copper and silver-epoxy/copper joints, while the contact electrical resistivity was measured. Cleansing of the copper surface was more effective for the reliability of silver-epoxy/copper joint than that of solder/copper joint. For sealing contacts, this work evaluated flexible graphite as an electromagnetic shielding gasket material. Flexible graphite was found to be at least comparable to conductive filled silicone (the state of the art) in terms of the shielding effectiveness. The conformability of flexible graphite with its mating metal surface under repeated compression was characterized by monitoring the contact electrical resistance, as the conformability is important to both electromagnetic scaling and fluid waling using flexible graphite. For mechanical contacts, this work focused on the correlation of the interface structure (such as elastic

  13. Mobile Phone-Based Joint Angle Measurement for Functional Assessment and Rehabilitation of Proprioception

    Directory of Open Access Journals (Sweden)

    Quentin Mourcou

    2015-01-01

    Full Text Available Assessment of joint functional and proprioceptive abilities is essential for balance, posture, and motor control rehabilitation. Joint functional ability refers to the capacity of movement of the joint. It may be evaluated thereby measuring the joint range of motion (ROM. Proprioception can be defined as the perception of the position and of the movement of various body parts in space. Its role is essential in sensorimotor control for movement acuity, joint stability, coordination, and balance. Its clinical evaluation is commonly based on the assessment of the joint position sense (JPS. Both ROM and JPS measurements require estimating angles through goniometer, scoliometer, laser-pointer, and bubble or digital inclinometer. With the arrival of Smartphones, these costly clinical tools tend to be replaced. Beyond evaluation, maintaining and/or improving joint functional and proprioceptive abilities by training with physical therapy is important for long-term management. This review aims to report Smartphone applications used for measuring and improving functional and proprioceptive abilities. It identifies that Smartphone applications are reliable for clinical measurements and are mainly used to assess ROM and JPS. However, there is lack of studies on Smartphone applications which can be used in an autonomous way to provide physical therapy exercises at home.

  14. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  15. Design and performance of a multi-centre randomised controlled trial and economic evaluation of joint tele-consultations [ISRCTN54264250

    Directory of Open Access Journals (Sweden)

    Thompson Simon

    2002-01-01

    Full Text Available Abstract Background Appropriate information flow is crucial to the care of patients, particularly at the interface between primary and secondary care. Communication problems can result from inadequate organisation and training, There is a major expectation that information and communication technologies may offer solutions, but little reliable evidence. This paper reports the design and performance of a multi-centre randomised controlled trial (RCT, unparalleled in telemedicine research in either scale or range of outcomes. The study investigated the effectiveness and cost implications in rural and inner-city settings of using videoconferencing to perform joint tele-consultations as an alternative to general practitioner referral to the hospital specialist in the outpatient clinic. Methods Joint tele-consultation services were established in both the Royal Free Hampstead NHS Trust in inner London, and the Royal Shrewsbury Hospitals Trust, in Shropshire. All the patients who gave consent to participate were randomised either to joint tele-consultation or to a routine outpatients appointment. The principal outcome measures included the frequency of decision by the specialist to offer a follow-up outpatient appointment, patient satisfaction (Ware Specific Questionnaire, wellbeing (SF12 and enablement (PEI, numbers of tests, investigations, procedures and treatments. Results A total of 134 general practitioners operating from 29 practices participated in the trial, referring a total of 3170 patients to 20 specialists in ENT medicine, general medicine (including endocrinology, and rheumatology, gastroenterology, orthopaedics, neurology and urology. Of these, 2094 patients consented to participate in the study and were correctly randomised. There was a 91% response rate to the initial assessment questionnaires, and analysis showed equivalence for all key characteristics between the treatment and control groups. Conclusion We have designed and

  16. American Evaluation Association Guiding Principles for Evaluators

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-01-18

    Five principles developed by American Evaluation Associ intended to guide professional practice of evaluators & to inform evaluation clients and the general public about principles they can expect to be upheld by professional evaluators.

  17. Heat Resistance of Glued Finger Joints in Spruce Wood Constructions

    Directory of Open Access Journals (Sweden)

    Martin Sviták

    2014-10-01

    Full Text Available The heat resistance of glued spruce wood was evaluated for different joint types and adhesives. Bending strength, modulus of elasticity, and also fracture evaluation were investigated on glued spruce samples made by the finger-jointed principle. Finger-jointed samples were glued with polyurethane (PUR and melamine-urea-formaldehyde (MUF adhesives. Heat loading was realized at temperatures 60, 80, and 110 °C and compared with wood with 20 °C. A static bending test with four-point flexural test was used. Elevated temperature and adhesive type had an important influence on the bending strength. On the other hand, adhesive type had a significant influence on the modulus of elasticity, but elevated temperature had no substantial influence.

  18. MR arthrography of the ankle joint

    International Nuclear Information System (INIS)

    Trattnig, S.; Rand, T.; Breitenseher, M.; Ba-Ssalamah, A.; Schick, S.; Imhof, H.

    1999-01-01

    Due to its superior soft tissue contrast conventional MRI is the imaging method of choice in the evaluation of ankle joint disorders. Conventional MR imaging can accurately demonstrate normal or acutely injured ligaments; however, in subacute and chronic injury joint fluid necessary for delineation of injured ligaments is absent and MR arthrography should be performed. MR arthrography uses the intraarticular injection of contrast material to distend the joint, yielding improved discrimination of intraarticular structures. This joint distension with MR arthrography is also helpful in the staging of osteochondritis dissecans, since in cases of unstable lesions tracking of contrast material into the interface can be more easily demonstrated. Finally, high contrast and joint distension by MR arthrography improves the detection of intraarticular loose bodies, which often require surgery. MR artrography, although invasive, may provide additional information in various ankle joint disorders. (orig.) [de

  19. Durability of saw-cut joints in plain cement concrete pavements.

    Science.gov (United States)

    2011-01-01

    The objective of this project was to evaluate factors influencing the durability of the joints in portland cement concrete : pavement in the state of Indiana. Specifically this work evaluated the absorption of water, the absorption of deicing solutio...

  20. Performance Evaluation of Nose Cap to Silica Tile Joint of RLV-TD under the Simulated Flight Environment using Plasma Wind Tunnel Facility

    Science.gov (United States)

    Pillai, Aravindakshan; Krishnaraj, K.; Sreenivas, N.; Nair, Praveen

    2017-12-01

    Indian Space Research Organisation, India has successfully flight tested the reusable launch vehicle through launching of a demonstration flight known as RLV-TD HEX mission. This mission has given a platform for exposing the thermal protection system to the real hypersonic flight thermal conditions and thereby validated the design. In this vehicle, the nose cap region is thermally protected by carbon-carbon followed by silica tiles with a gap in between them for thermal expansion. The gap is filled with silica fibre. Base material on which the C-C is placed is made of molybdenum. Silica tile with strain isolation pad is bonded to aluminium structure. These interfaces with a variety of materials are characterised with different coefficients of thermal expansion joined together. In order to evaluate and qualify this joint, model tests were carried out in Plasma Wind Tunnel facility under the simultaneous simulation of heat flux and shear levels as expected in flight. The thermal and flow parameters around the model are determined and made available for the thermal analysis using in-house CFD code. Two tests were carried out. The measured temperatures at different locations were benign in both these tests and the SiC coating on C-C and the interface were also intact. These tests essentially qualified the joint interface between C-C and molybdenum bracket and C-C to silica tile interface of RLV-TD.

  1. T2 Mapping of Articular Cartilage of Glenohumeral Joint with Routine MRI Correlation—Initial Experience

    OpenAIRE

    Maizlin, Zeev V.; Clement, Jason J.; Patola, Wayne B.; Fenton, David M.; Gillies, Jean H.; Vos, Patrick M.; Jacobson, Jon A.

    2009-01-01

    The evaluation of articular cartilage currently relies primarily on the identification of morphological alterations of the articular cartilage. Unlike anatomic imaging, T2 mapping is sensitive to changes in the chemical composition and structure of the cartilage. Clinical evaluation of T2 mapping of the glenohumeral joint has not been previously reported. The objectives of this study were to evaluate the feasibility of magnetic resonance T2 mapping of the glenohumeral joint in routine clinica...

  2. An ultrasonographic study on measurement of normal hip joint in Korean

    International Nuclear Information System (INIS)

    Lim, Hyo Keun; Choo, In Wook; Park, Soo Sung; Han, Man Chung

    1989-01-01

    The ultrasonography is very useful in evaluation of small amount of effusion in hip joint and has several advantages such as noninvasiveness, easiness, accuracy and no radiation hazard. The data of normal hip joint space and capsule is very important in ultrasonographic evaluation of inflammatory hip joint disease. However, normal ultrasonographic data of hip joint has not been reported except in pediatric age. The purpose of this study was to evaluate and measure normal hip joint space and capsule and to provide the basic data for the clinical application. Healthy 70 males and 70 females who have had no past history and present clinical symptom of hip joint were examined with real time sector scanner (5MHz transducer). Width of hip joint spaces and thickness of joint capsule were obtained and analysed by statistical analysis. The results were as follows: 1. The average width of the hip joint space were 2.6±0.5 mm (right), 2.5±0.5 mm (left) in males and 2.4±0.5 (right), 2.5±0.6 mm (left) in females. There was no significant difference by sex. 2. The widths of the hip joint space were increased with aging and decreased after 6th decade (male) and 5th decade (females). 3. The maximal difference of both hip joint space was 1.2 mm and there was no significant difference in both side by sex and age. 4. The average thicknesses of hip joint capsule were 1.9±0.3 mm (right), 1.8±0.2 mm (left) in males and 1.7±0.3 mm (right), 1.7±0.2 mm (left) in females. There was no significant difference by sex. 5. The thickness of the hip joint capsule were increased with aging and were in plateau after 5th decade (male and female). 6. The maximal difference of both hip joint capsules was 0.9 mm and there was no significant difference in both sides by sex and age. It is therefore, considered that ultrasonography could be a very useful modality in diagnosis of hip joint disease in which the hip joint space and the hip joint capsule are changed by various etiologies

  3. Evaluation of certain food additives and contaminants.

    Science.gov (United States)

    2013-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives and a food contaminant with a view to concluding as to safety concerns and to preparing specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation of and assessment of dietary exposure to food additives. A summary follows of the Committee's evaluations of technical, toxicological and dietary exposure data for seven food additives (advantame; glucoamylase from Trichoderma reesei expressed in Trichoderma reesei; glycerol ester of gum rosin; glycerol ester of tall oil rosin; glycerol ester of wood rosin; nisin; and octenyl succinic acid modified gum arabic) and an assessment of dietary exposure to cadmium from cocoa and cocoa products. Specifications for the following food additives were revised: annatto extracts (solvent-extracted bixin and solvent-extracted norbixin); Benzoe tonkinensis; food additives containing aluminium and/or silicon; mineral oil (medium viscosity); modified starches; paprika extract; phosphates (analytical methods for the determination of phosphorus and revision of specifications); 3-phytase from Aspergillus niger expressed in Aspergillus niger; potassium aluminium silicate; and potassium aluminium silicate-based pearlescent pigments. Annexed to the report are tables summarizing the Committee's recommendations for dietary exposures to and toxicological evaluations of the food additives and contaminant considered.

  4. Evaluation of Pain Syndromes, Headache, and Temporomandibular Joint Disorders in Children.

    Science.gov (United States)

    Horswell, Bruce B; Sheikh, Jason

    2018-02-01

    After a thorough review of the history and presentation of a child's facial pain, a targeted head and neck examination is critical to the appropriate diagnosis of facial pain and temporomandibular joint disorders. It is critical to distinguish between the structural (trauma, degenerative disease, and tumor) and nonstructural (neurogenic, myogenic, and psychological) causes of pain, which will allow for incorporation of appropriate strategies of medical, psychological, dental, and surgical therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Lumbar facet syndrome - Lumbar facet joint injection and low back pain

    International Nuclear Information System (INIS)

    Acevedo Gonzalez, Juan Carlos; Jimenez Hakim, Enrique; Rodriguez, Jose Maria; Hakim Daccach, Fernando; Quinonez, German; Rodriguez Munera, Andres

    2004-01-01

    The authors conducted a retrospective study lo evaluate the effectiveness of injection therapy in the lumbar zygapophysial joints with anesthetics and steroids in patients with persisting low back pain and lumbar facer syndrome. Thirty-seven patients with low back pain who reported immediate relief of their pain after controlled blocks into the facet joints between the fourth and fifth lumbar vertebrae and the fifth lumbar and first sacral vertebrae were evaluated. Outcome was evaluated using the visual analog pain scales. All outcome measures were repeated at eight days and six weeks alter controlled injection. At six-week follow-up examination 83,7% of thirty-seven patients experienced a good response to controlled blocks of the lumbar zygaphyseal (facet) joints. Good result is the pain relief of 50% or more. Fifteen patients experienced a good response with pain relief of eight points or more in the VAS

  6. Development of a comprehensive management site evaluation methodology

    International Nuclear Information System (INIS)

    Rodgers, J.C.; Onishi, Y.

    1981-01-01

    The Nuclear Regulatory Commission is in the process of preparing regulations that will define the necessary conditions for adequate disposal of low-level waste (LLW) by confinement in an LLW disposal facility. These proposed regulations form the context in which the motivation for the joint Los Alamos National Laboratory Battelle Pacific Northwest Laboratory program to develop a site-specific, LLW site evaluation methodology is discussed. The overall effort is divided into three development areas: land-use evaluation, environmental transport modelling, and long term scenario development including long-range climatology projections. At the present time four steps are envisioned in the application of the methodology to a site: site land use suitability assessment, land use-ecosystem interaction, contaminant transport simulation, and sensitivity analysis. Each of these steps is discussed in the paper. 12 refs

  7. Evaluating how we evaluate.

    Science.gov (United States)

    Vale, Ronald D

    2012-09-01

    Evaluation of scientific work underlies the process of career advancement in academic science, with publications being a fundamental metric. Many aspects of the evaluation process for grants and promotions are deeply ingrained in institutions and funding agencies and have been altered very little in the past several decades, despite substantial changes that have taken place in the scientific work force, the funding landscape, and the way that science is being conducted. This article examines how scientific productivity is being evaluated, what it is rewarding, where it falls short, and why richer information than a standard curriculum vitae/biosketch might provide a more accurate picture of scientific and educational contributions. The article also explores how the evaluation process exerts a profound influence on many aspects of the scientific enterprise, including the training of new scientists, the way in which grant resources are distributed, the manner in which new knowledge is published, and the culture of science itself.

  8. Computed tomography of human joints and radioactive waste drums

    International Nuclear Information System (INIS)

    Martz, Harry E.; Roberson, G. Patrick; Hollerbach, Karin; Logan, Clinton M.; Ashby, Elaine; Bernardi, Richard

    1999-01-01

    X- and gamma-ray imaging techniques in nondestructive evaluation (NDE) and assay (NDA) have seen increasing use in an array of industrial, environmental, military, and medical applications. Much of this growth in recent years is attributed to the rapid development of computed tomography (CT) and the use of NDE throughout the life-cycle of a product. Two diverse examples of CT are discussed, 1.) Our computational approach to normal joint kinematics and prosthetic joint analysis offers an opportunity to evaluate and improve prosthetic human joint replacements before they are manufactured or surgically implanted. Computed tomography data from scanned joints are segmented, resulting in the identification of bone and other tissues of interest, with emphasis on the articular surfaces. 2.) We are developing NDE and NDA techniques to analyze closed waste drums accurately and quantitatively. Active and passive computed tomography (A and PCT) is a comprehensive and accurate gamma-ray NDA method that can identify all detectable radioisotopes present in a container and measure their radioactivity

  9. Principles of Human Joint Replacement Design and Clinical Application

    CERN Document Server

    Buechel, Frederick F

    2012-01-01

    Drs. Buechel, an orthopaedic surgeon, and Pappas, a professor of Mechanical Engineering, are the designers of several successful joint replacement systems. The most well-known of these is the pioneering LCS knee replacement. They have written this book for the users and designers of joint replacements. It is an attempt to convey to the reader the knowledge accumulated by the authors during their thirty five year effort on the development of replacement devices for the lower limb for the purpose of aiding the reader in their design and evaluation of joint replacement devices. The early chapters describe the engineering, scientific and medical principles needed for replacement joint evaluation. One must understand the nature and performance of the materials involved and their characteristics in vivo, i.e. the response of the body to implant materials. It is also essential to understand the response of the implants to applied loading and motion, particularly in the hostile physiological environment. A chapter de...

  10. Study to improve recriticality evaluation methodology after severe accident (Joint research)

    International Nuclear Information System (INIS)

    Kugo, Teruhiko; Ishikawa, Makoto; Nagaya, Yasunobu; Yokoyama, Kenji; Fukaya, Yuji; Maruyama, Hiromi; Kondo, Takao; Minato, Hirokazu; Tsuchiya, Akiyuki; Ishii, Yoshihiko; Fujimura, Koji

    2014-03-01

    The present report summarizes the results of a 2-year cooperative study between JAEA and Hitachi-GE Nuclear Energy in order to contribute to the settlement of the Fukushima-Daiich nuclear power plants which suffered from the severe accident on March 2011. In the Fukushima-Daiich plants, it is considered that the nuclear fuel in the core was melted down by the loss of ultimate heat sink by the station black out after the 2011 off the Pacific coast of Tohoku Earthquake. The position and/or the mass of the melted fuel have not been known yet. Therefore, the possibility of recriticality events and the severity of the postulated recriticality are uncertain. In the present study, the possible scenarios to reach the recriticality events in Fukushima-Daiich were investigated first. Then, the analytical methodology to evaluate the time-dependent recriticality events has been developed by modelling the reactivity insertion rate and the possible feedback according to the recriticality scenarios identified in the first step. The methodology developed here has been equipped as a transient simulation tool, PORCAS, which is operated on a multi-purpose platform for reactor analysis, MARBLE. Finally, the radiation exposure rates by the postulated recriticality events in Fukushima-Daiich were approximately evaluated to estimate the impact to the public environment. (author)

  11. Analytical and experimental evaluation of joining silicon nitride to metal and silicon carbide to metal for advanced heat engine applications. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, S.; Selverian, J.H.; O`Neil, D.; Kim, H. [GTE Labs., Inc., Waltham, MA (US); Kim, K. [Brown Univ., Providence, RI (US). Div. of Engineering

    1993-05-01

    This report summarizes the results of Phase 2 of Analytical and Experimental Evaluation of Joining Silicon Nitride to Metal and Silicon Carbide to Metal for Advanced Heat Engine Applications. A general methodology was developed to optimize the joint geometry and material systems for 650{degrees}C applications. Failure criteria were derived to predict the fracture of the braze and ceramic. Extensive finite element analyses (FEA) were performed to examine various joint geometries and to evaluate the affect of different interlayers on the residual stress state. Also, material systems composed of coating materials, interlayers, and braze alloys were developed for the program based on the chemical stability and strength of the joints during processing, and service. The FEA results were compared with experiments using two methods: (1) an idealized strength relationship of the ceramic, and (2) a probabilistic analysis of the ceramic strength (NASA CARES). The results showed that the measured strength of the joint reached 30--80% of the strength predicted by FEA. Also, potential high-temperature braze alloys were developed and evaluated for the high-temperature application of ceramic-metal joints. 38 tabs, 29 figs, 20 refs.

  12. Nuclear data evaluation method and evaluation system

    International Nuclear Information System (INIS)

    Liu Tingjin

    1995-01-01

    The evaluation methods and Nuclear Data Evaluation System have been developed in China. A new version of the system has been established on Micro-VAX2 computer, which is supported by IAEA under the technology assistance program. The flow chart of Chinese Nuclear Data Evaluation System is shown out. For last ten years, the main efforts have been put on the double differential cross section, covariance data and evaluated data library validation. The developed evaluation method and Chinese Nuclear Data Evaluation System have been widely used at CNDC and in Chinese Nuclear Data Network for CENDL. (1 tab., 15 figs.)

  13. EFSA Scientific Opinion on Flavouring Group Evaluation 78, Revision 1 (FGE.78Rev1): Consideration of aliphatic and alicyclic and aromatic hydrocarbons evaluated by JECFA (63rd meeting) structurally related to aliphatic and aromatic hydrocarbons evaluated by EFSA in FGE.25Rev2

    DEFF Research Database (Denmark)

    Larsen, John Christian; Nørby, Karin Kristiane; Beltoft, Vibe Meister

    The Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids of the European Food Safety Authority was requested to consider evaluations of flavouring substances assessed since 2000 by the Joint FAO/WHO Expert Committee on Food Additives (the JECFA), and to decide whether further...... and toxicity. Two substances [FL-no: 01.011 and 01.013] are genotoxic in vitro and potentially carcinogenic, and are therefore not evaluated using the Procedure. The Panel concluded that the nine substance [FL-no: 01.002, 01.005, 01.006, 01.010, 01.016, 01.019, 01.020, 01.045 and 01.077] do not give rise...

  14. Ankle tenosynovitis in rheumatoid arthritis: clinical and ultrasonographic evaluation

    Directory of Open Access Journals (Sweden)

    Ana Luiza Naves Pereira

    2016-11-01

    Full Text Available Objective: To investigate ankle tenosynovitis in rheumatoid arthritis patients, regarding its presence, the kind of tendon involved and the concordance between clinical and ultrasound findings. Methods: Twenty patients with rheumatoid arthritis and pain or swollen ankle joint were evaluated. Tendon involvement was evaluated with ultrasound imaging. The Health Assessment Questionnaire (HAQ was performed for disability evaluation. Age, sex, disease duration, and vocational activity levels were also obtained. The statistical analysis included Fisher’s exact test. The significance level was 0.05. Results: Tenosynovitis was found in 13 of 20 (65.0% patients in 19 joints, in which 6 were bilaterally (46.1% and unilateral in 7 (53.8%. Tibialis posterior tenosynovitis was seen in nine (45.0% patients, Achilles tenosynovitis in seven (35.0%, tibialis anterior tenosynovitis in three (15.0%, and peroneal tenosynovitis in three (15.0% patients. We found concordance between symptomatic ankle and ultrasonographic findings in 92.3% of the patients with tenosynovitis. Association between severe HAQ with tendon involvement was not found (p>0.05. Disease duration was not associated with tenosynovitis. Patients were predominantly older, female, with mean age around 50.8 years. The long disease duration of patients presented a mean of 11.4 years and, most of them, with no vocational activity (65.0%. Conclusions: The results indicate that ankle tenosynovitis is very common in rheumatoid arthritis patients, both unilateral and bilateral. Tibialis posterior was the most common tendon involvement found. Finally, we found concordance between the clinical and ultrasound findings in almost all rheumatoid arthritis patients with ankle tenosynovitis.

  15. [Clinical evaluation and psychological aspects of temporomandibular joint disorders].

    Science.gov (United States)

    Coessens, P; De Boever, J A

    1997-01-01

    Establishing the patient's clinical diagnosis depends on gathering as much information of the patient and his or her signs and symptoms as possible. This information can be gathered from history, physical and psychological examination, diagnostic analysis. It is also important to look upon pain as a disorder and to consider the relationship between pain and psychological factors. The differential diagnosis is constructed through a biopsychological model of illness rather than through a more traditional biomedical model of disease. To arrive at a consistently accurate clinical diagnosis in patients with TMJ and craniofacial pain, the technique of clinical diagnosis must be well defined, reliable and include examination of the head and the neck, cranial nerves and the stomatognathic system. The craniomandibular index provides a standardized examination of the stomatognathic system that has been tested on validity and reliability. This chapter focuses on the techniques of history taking clinical and psychological examination and diagnostic criteria for temporomandibular joint disorders and muscle pain.

  16. Evaluation of certain food additives.

    Science.gov (United States)

    2009-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives, including flavouring agents, with a view to recommending acceptable daily intakes (ADIs) and to preparing specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation and assessment of intake of food additives (in particular, flavouring agents). A summary follows of the Committee's evaluations of technical, toxicological and intake data for certain food additives (asparaginase from Aspergillus niger expressed in A. niger, calcium lignosulfonate (40-65), ethyl lauroyl arginate, paprika extract, phospholipase C expressed in Pichia pastoris, phytosterols, phytostanols and their esters, polydimethylsiloxane, steviol glycosides and sulfites [assessment of dietary exposure]) and 10 groups of related flavouring agents (aliphatic branched-chain saturated and unsaturated alcohols, aldehydes, acids and related esters; aliphatic linear alpha,beta-unsaturated aldehydes, acids and related alcohols, acetals and esters; aliphatic secondary alcohols, ketones and related esters; alkoxy-substituted allylbenzenes present in foods and essential oils and used as flavouring agents; esters of aliphatic acyclic primary alcohols with aliphatic linear saturated carboxylic acids; furan-substituted aliphatic hydrocarbons, alcohols, aldehydes, ketones, carboxylic acids and related esters, sulfides, disulfides and ethers; miscellaneous nitrogen-containing substances; monocyclic and bicyclic secondary alcohols, ketones and related esters; hydroxy- and alkoxy-substituted benzyl derivatives; and substances structurally related to menthol). Specifications for the following food additives were revised: canthaxanthin; carob bean gum and carob bean gum (clarified); chlorophyllin copper complexes, sodium and potassium salts; Fast Green FCF; guar gum and guar gum (clarified

  17. Traumatic injuries of the temporomandibular joint

    International Nuclear Information System (INIS)

    Puig, S.; Krestan, C.; Lomoschitz, F.; Robinson, S.; Glaser, C.; Staudenherz, A.

    2001-01-01

    Injuries of the temporomandibular joint are mostly due to injuries or fractures of the mandibular condyle. Fractures of the skull base involving the temporomandibular joint are rare. Classification of fractures refers to their anatomical positions and the presence or absence of a luxation. Further, it is important whether the fracture is intra- or extra-capsular. The primary imaging method should be orthopantomography. As for therapy planning, especially surgery, also evaluation of soft tissue is necessary, computed tomography is the imaging method of choice. For diagnosis of complications or internal derangement of the temporomandibular joint, magnetic resonance imaging is to be recommended. (orig.) [de

  18. Evaluation of Outcomes of Open Reduction and Internal Fixation Surgery in Patients with Type C Distal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Mohammadhadi Nouraei

    2018-01-01

    Full Text Available Background: In this study, functional state of patients with Type C distal humerus fractures undergone surgical plating was evaluated 6 and 12 months after the surgery in order to record postsurgical factors such as pain level and job/performance satisfaction. Materials and Methods: In this cross-sectional study, 46 patients with humerus fractures were recruited and their ability to do daily tasks, presence of degenerative changes, stability of elbow joint, and range of motion was evaluated. For assessment of response to surgery, Mayo score was used. Results: Among 46 patients, 45 (97.8% of them had joint stability. Evaluation of postsurgical complications showed that six subjects (13% had no complications, but superficial infection was observed in 12 (26.1% subjects. Neuromuscular disorders in ulnar nerve were present in 11 subjects (23.9%, recurrent articular bursitis of elbow joint in 6 subjects (13%, stiffness of elbow joint in 29 subjects (63%, nonunion of fracture in 3 subjects (6.5%, and myositis ossification in 4 (8.7% subjects. Furthermore, 18 (39.1% patients presented with more than one (2–4 complications. Conclusion: Open reduction and internal fixation surgery with dual plating is the method of choice for treatment of Type C distal humeral fractures. Evaluation of long-term outcomes of this surgery could be done via several different questionnaires as many studies suggest. This study demonstrated that the outcomes of this surgery in Isfahan, Iran, have been noticeably inferior compared to results of the studies in other parts of the world.

  19. Assessing sufficient capability: A new approach to economic evaluation.

    Science.gov (United States)

    Mitchell, Paul Mark; Roberts, Tracy E; Barton, Pelham M; Coast, Joanna

    2015-08-01

    Amartya Sen's capability approach has been discussed widely in the health economics discipline. Although measures have been developed to assess capability in economic evaluation, there has been much less attention paid to the decision rules that might be applied alongside. Here, new methods, drawing on the multidimensional poverty and health economics literature, are developed for conducting economic evaluation within the capability approach and focusing on an objective of achieving "sufficient capability". This objective more closely reflects the concern with equity that pervades the capability approach and the method has the advantage of retaining the longitudinal aspect of estimating outcome that is associated with quality-adjusted life years (QALYs), whilst also drawing on notions of shortfall associated with assessments of poverty. Economic evaluation from this perspective is illustrated in an osteoarthritis patient group undergoing joint replacement, with capability wellbeing assessed using ICECAP-O. Recommendations for taking the sufficient capability approach forward are provided. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Iranian Joint Registry(Iranian National Hip and Knee Arthroplasty Registry

    Directory of Open Access Journals (Sweden)

    Hamidreza Aslani

    2016-04-01

    Full Text Available Periodic evaluation and monitoring the health and economic outcome of joint replacement surgery is a common and popular process under the territory of joint registries in many countries. In this article we introduce the methodology used for the foundation of the National Iranian Joint Registry (IJR with a joint collaboration of the Social Security Organization (SSO and academic research departments considering the requirements of the Iran’s Ministry of Health and Education.

  1. Variability and Similarity of Gait as Evaluated by Joint Angles

    DEFF Research Database (Denmark)

    Yang, Sylvia X M; Larsen, Peter Kastmand; Alkjær, Tine

    2014-01-01

    . Six sets from 12 men were collected. For each man, a variability range VR (mean ± 1SD) of a specific joint angle at a specific time point (a gait cycle was 100 time points) was calculated. In turn, each individual was compared with the 11 others, and whenever 1 of these 11 had a value within...... this individual’s VR, it counted as positive. By adding the positives throughout the gait cycle, we created simple bar graphs; tall bars indicated a small discriminatory power, short bars indicated a larger one. The highest discriminatory power was at time points 60–80 in the gait cycle. We show how our data can...

  2. Evaluation of the activity of rheumatoid arthritis in clinical practice. Agreement between self-rated clinimetric evaluation and clinical evaluation with activity indexes: DAS28, CDAI and SDAI.

    Science.gov (United States)

    Horta-Baas, Gabriel; Pérez Bolde-Hernández, Arturo; Hernández-Cabrera, María Fernanda; Vergara-Sánchez, Imelda; Romero-Figueroa, María Del Socorro

    2017-10-11

    To achieve control of rheumatoid arthritis (RA) it is necessary to be able to evaluate its activity. The American College of Rheumatology (ACR) recommends for this purpose indexes of activity that can be performed by the patient (PAS-II and RAPID-3) and IA including medical evaluation with laboratory studies (DAS28 and SDAI) or without them (CDAI). The objective was to analyze the concordance between self-rated clinimetric evaluation and clinimetric evaluation performed by the physician. Analytical cross-sectional study in 126 patients with RA. The agreement was evaluated through the weighted κ coefficient and the Krippendorff's α coefficient. The PAS-II and RAPID-3 significantly correlated with all variables included in the core set of measures recommended by the ACR/EULAR. The agreement between PAS-II and CDAI-SDAI was good (κ: 0.6, α: 0.61-0.62), and moderate with DAS28-ESR (κ: 0.53, α: 0.56). The concordance between RAPID-3 and CDAI-SDAI was moderate (κ: 0.55-0.57, α: 0.50-0.51), and moderate with DAS28-ESR (κ: 0.55, α: 0.53). When categorizing the activity in remission/low activity vs. moderate/severe activity, the agreement was greater with the PAS-II (0.59 vs. 0.34; P=.012). The good concordance between PAS-II and SDAI supports their use in clinical practice, especially if biomarkers of inflammation or the possibility of joint count are not available. However, in order to recommend its routine application in clinical practice, it is necessary to perform longitudinal studies that assess its responsiveness. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  3. Significance of the Lateral Humeral Line for Evaluating Radiocapitellar Alignment in Children.

    Science.gov (United States)

    Souder, Christopher D; Roocroft, Joanna H; Edmonds, Eric W

    The radiocapitellar line (RCL) was originally described for evaluation of the alignment of the RC joint on lateral images of the elbow. Although, many authors have translated the utilization of RCL into coronal imaging, previous studies have not been performed to confirm validity. The purpose of this paper was to identify an accurate way of evaluating pediatric RC alignment in the coronal plane. Thirty-seven anteroposterior (AP) radiographs of 37 children were evaluated to determine the position of the RC joint in the coronal plane. All had acceptable magnetic resonance imaging (MRI) studies available for comparison. The lateral humeral line (LHL), consisting of a line along the lateral edge of the ossified condyle of the distal humerus parallel to the axis of the distal humeral shaft, was studied as it related to the lateral cortex of the radial neck. Three children with a confirmed diagnosis of a Bado III, lateral displaced radius, Monteggia fracture were also evaluated. The LHL passed along the edge of or lateral to the radial neck on all AP radiographs and all MRI studies. The RCL failed to intersect the capitellum on 2 AP radiographs. On MRI, the RCL also passed lateral to the capitellar ossification center in 3 patients. In addition, the RCL was seen passing through the capitellum at a mean of the lateral 30% (range, 0% to 64%) on AP radiographs and 26% (range, 0% to 48%) on MRI. For all 3 children with a Bado III Monteggia fracture, the LHL crossed the radial neck and the RCL did not intersect the capitellum. The RCL can fail to intersect the capitellar ossification center on AP radiographs and MRI in pediatric elbows without injury. The LHL consistently lies lateral to the radial neck in normal elbows and medial to the lateral aspect of the radial neck on all Bado III fracture-dislocations. It, therefore, can be used as an adjunct in evaluating the RC joint on AP imaging. The RCL most commonly intersects the lateral one third of the ossification center on

  4. Geomechanical Response of Jointed Caprock During CO2 Geological Sequestration

    Science.gov (United States)

    Newell, P.; Martinez, M. J.; Bishop, J. E.

    2014-12-01

    Geological sequestration of CO2 refers to the injection of supercritical CO2 into deep reservoirs trapped beneath a low-permeability caprock formation. Maintaining caprock integrity during the injection process is the most important factor for a successful injection. In this work we evaluate the potential for jointed caprock during injection scenarios using coupled three-dimensional multiphase flow and geomechanics modeling. Evaluation of jointed/fractured caprock systems is of particular concern to CO2 sequestration because creation or reactivation of joints (mechanical damage) can lead to enhanced pathways for leakage. In this work, we use an equivalent continuum approach to account for the joints within the caprock. Joint's aperture and non-linear stiffness of the caprock will be updated dynamically based on the effective normal stress. Effective permeability field will be updated based on the joints' aperture creating an anisotropic permeability field throughout the caprock. This feature would add another coupling between the solid and fluid in addition to basic Terzaghi's effective stress concept. In this study, we evaluate the impact of the joint's orientation and geometry of caprock and reservoir layers on geomechanical response of the CO2 geological systems. This work is supported as part of the Center for Frontiers of Subsurface Energy Security, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Award Number DE-SC0001114. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  5. Pictorial review: MRI of the sternum and sternoclavicular joints.

    Science.gov (United States)

    Aslam, M; Rajesh, A; Entwisle, J; Jeyapalan, K

    2002-07-01

    The sternum and sternoclavicular joints are difficult to evaluate with plain radiographs. The value of CT in assessing lesions of the sternum and sternoclavicular joints has been well documented, but the potential role of MRI has not been emphasized. We present the MRI techniques, normal appearances and a spectrum of abnormalities, and emphasize the role of MRI as a useful radiological investigation for the sternum and sternoclavicular joints.

  6. Association between CT-evaluated lumbar lordosis and features of spinal degeneration, evaluated in supine position

    Science.gov (United States)

    Kalichman, Leonid; Li, Ling; Hunter, David; Been, Ella

    2013-01-01

    Background Context Few studies have directly evaluated the association of lumbar lordosis and segmental wedging of the vertebral bodies and intervertebral disks with prevalence of spinal degenerative features. Purpose To evaluate the association of CT-evaluated lumbar lordosis, segmental wedging of the vertebral bodies and that of the intervertebral disks with various spinal degeneration features. Study design This cross-sectional study was a nested project to the Framingham Heart Study. Sample A random consecutive subset of 191 participants chosen from the 3590 participants enrolled in the Framingham Heart Study who underwent multi-detector CT to assess aortic calcification. Outcome Measures Physiologic Measures Dichotomous variables indicating the presence of intervertebral disc narrowing, facet joint osteoarthritis, spondylolysis, spondylolisthesis and spinal stenosis and density (in Hounsfield units) of multifidus and erector spinae muscles were evaluated on supine CT, as well as the lordosis angle (LA) and the wedging of the vertebral bodies and intervertebral disks. Sum of vertebral bodies wedging (ΣB) and sum of intervertebral discs wedging (ΣD) were used in analyses. Methods Mean values (±SD) of LA, ΣB and ΣD were calculated in males and females and compared using the t-test. Mean values (±SD) of LA, ΣB and ΣD in 4 age groups: 0.05) with increasing age. LA showed statistically significant association with presence of spondylolysis (OR(95%CI): 1.08(1.02–1.14)) and with density of multifidus (1.06 (1.01–1.11). as well as a marginally significant association with isthmic spondylolisthesis (1.07(1.00–1.14). ΣB showed a positive association with degenerative spondylolisthesis and disc narrowing ((1.14(1.06–1.23) and 1.04 (1.00–1.08), correspondingly), whereas ΣD showed negative one (0.93(0.87–0.98) and (0.93(0.89–0.97), correspondingly). Conclusions Significant associations were found between lumbar lordosis evaluated in supine position

  7. Thermal imaging in screening of joint inflammation and rheumatoid arthritis in children

    International Nuclear Information System (INIS)

    Lasanen, R; Julkunen, P; Töyräs, J; Piippo-Savolainen, E; Remes-Pakarinen, T; Kröger, L; Heikkilä, A; Karhu, J

    2015-01-01

    Potential of modern thermal imaging for screening and differentiation of joint inflammation has not been assessed in child and juvenile patient populations, typically demanding groups in diagnostics of musculoskeletal disorders. We hypothesize that thermal imaging can detect joint inflammation in patients with juvenile idiopathic arthritis or autoimmune disease with arthritis such as systemic lupus erythematosus. To evaluate the hypothesis, we studied 58 children exhibiting symptoms of joint inflammation. First, the patients’ joints were examined along clinical procedure supplemented with ultrasound imaging when deemed necessary by the clinician. Second, thermal images were acquired from patients’ knees and ankles. Results of thermal imaging were compared to clinical evaluations in knee and ankle. The temperatures were significantly (p max = 0.044, p mean  < 0.001) higher in inflamed ankle joints, but not in inflamed knee joints. No significant difference was found between the skin surface temperatures of medial and lateral aspects of ankle joints. In knee joints the mean temperatures of medial and lateral aspect differed significantly (p = 0.004). We have demonstrated that thermal imaging may have potential for detecting joint inflammation in ankle joints of children. For knee joints our results are inconclusive and further research is warranted. (paper)

  8. Evaluation of certain food additives.

    Science.gov (United States)

    2012-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives, including flavouring agents, with a view to concluding as to safety concerns and to preparing specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation of and assessment of dietary exposure to food additives, including flavouring agents. A summary follows of the Committee's evaluations of technical, toxicological and dietary exposure data for five food additives (magnesium dihydrogen diphosphate; mineral oil (medium and low viscosity) classes II and III; 3-phytase from Aspergillus niger expressed in Aspergillus niger; serine protease (chymotrypsin) from Nocardiopsis prasina expressed in Bacillus licheniformis; and serine protease (trypsin) from Fusarium oxysporum expressed in Fusarium venenatum) and 16 groups of flavouring agents (aliphatic and aromatic amines and amides; aliphatic and aromatic ethers; aliphatic hydrocarbons, alcohols, aldehydes, ketones, carboxylic acids and related esters, sulfides, disulfides and ethers containing furan substitution; aliphatic linear alpha,beta-unsaturated aldehydes, acids and related alcohols, acetals and esters; amino acids and related substances; epoxides; furfuryl alcohol and related substances; linear and branched-chain aliphatic, unsaturated, unconjugated alcohols, aldehydes, acids and related esters; miscellaneous nitrogen-containing substances; phenol and phenol derivatives; pyrazine derivatives; pyridine, pyrrole and quinoline derivatives; saturated aliphatic acyclic branched-chain primary alcohols, aldehydes and acids; simple aliphatic and aromatic sulfides and thiols; sulfur-containing heterocyclic compounds; and sulfur-substituted furan derivatives). Specifications for the following food additives were revised: ethyl cellulose, mineral oil (medium viscosity), modified starches and titanium

  9. EFSA CEF Panel (EFSA Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids), 2016 Scientific Opinion on Flavouring Group Evaluation 75, Revision 1 (FGE.75Rev1): Consideration of tetrahydrofuran derivatives evaluated by JECFA (63rd meeting) structurally related to tetrahydrofuran

    DEFF Research Database (Denmark)

    Beltoft, Vibe Meister; Nørby, Karin Kristiane

    The Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids (CEF) of the EFSA was requested to consider evaluations of flavouring substances assessed since 2000 by the Joint FAO/WHO Expert Committee on Food Additives (the JECFA), and to decide whether further evaluation is neces......The Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids (CEF) of the EFSA was requested to consider evaluations of flavouring substances assessed since 2000 by the Joint FAO/WHO Expert Committee on Food Additives (the JECFA), and to decide whether further evaluation...... for anhydrolinalool oxide (5) [FL-no: 13.097]. The substances were evaluated through a stepwise approach that integrates information on structure-activity relationships, intake from current uses, toxicological threshold of concern, and available data on metabolism and toxicity. The JECFA concluded all the 11...... with the JECFA conclusion ‘No safety concern at estimated level of intake as flavouring substances’ based on the maximised survey-derived daily intake (MSDI) approach. The specifications for the materials of commerce have also been considered and for all 11 substances, the information is adequate....

  10. Imaging findings of charcot joint

    International Nuclear Information System (INIS)

    Meng Quanfei; Zhou Chunxiang; Chen Yingming; Jiang Bo

    2003-01-01

    Objective: To analyze the MRI characters of Charcot joint, and to evaluate the diagnostic value of X-ray, CT, and MRI on Charcot joint. Methods: Eight patients with 8 Charcot joints underwent X-ray, CT, and MR examinations. 6 of them had syringomyelia, 1 patient had injury of the spinal cord, and 1 case had diabetes. All 8 patients had sensory reduction or deficit in the sick extremities. Results: There were two types of Charcot joint, hypertrophic and atrophic. Radiographic and CT features of hypertrophic joint (n=3) showed hyperostotic osteosclerosis and mammoth osteophytes in the sick bones, periarticular ossification, and articular disorganization. Radiographic and CT features of atrophic joint (n=5) showed extensive bone resorption (destruction), periarticular debris, and articular disorganization. Main MRI features of Charcot joint included hydrarthrosis within joint capsule, thickened, loose, and elongated joint capsule with para-joint, peri-diaphysis, and inter-muscular extension in a pseudopodia pattern. The irregular joint capsule wall was presented as mild hypointensity on T 1 WI, slight hyper-intensity on T 2 WI, and was markedly enhanced after Gd-DTPA was administrated, which was considered as a characteristic manifestation of the lesion. Soft tissue mass containing hypo-intense stripes on both T 1 WI and T 2 WI was commonly noted adjacent to the involved joint. Conclusion: X-rays plain film is the first choice for the diagnosis of Charcot joint, and MRI is pretty useful in the diagnosis of Charcot joint

  11. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty

    Directory of Open Access Journals (Sweden)

    Czech Szymon

    2017-12-01

    Full Text Available An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients’ willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  12. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty.

    Science.gov (United States)

    Czech, Szymon; Hermanson, Jacek; Rodak, Piotr; Stołtny, Tomasz; Rodak, Łukasz; Kasperczyk, Sławomir; Koczy, Bogdan; Mielnik, Michał

    2017-12-01

    An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients' willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  13. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    Science.gov (United States)

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  14. Joint shape segmentation with linear programming

    KAUST Repository

    Huang, Qixing; Koltun, Vladlen; Guibas, Leonidas

    2011-01-01

    program is solved via a linear programming relaxation, using a block coordinate descent procedure that makes the optimization feasible for large databases. We evaluate the presented approach on the Princeton segmentation benchmark and show that joint shape

  15. Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Young Yiul; Park, Seon Yang; Lee, Myung Chul; Choi, Sang Jae; Cho, Bo Youn; Choe, Kang Won; Koh, Chang Soon

    1982-01-01

    To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio (SIS Ratio) by region of interest (ROI) method using 99m Tc-methylene diphosphonate. The observed results were as follows:1) Using ROI method, the SIS ratios for the control group of 65 persons were 1.05±0.08 (left) and 1.06±0.07 (right) which were narrower in range than those of slice method (mean±S.D.) 2) The effects of age, gender and laterality on SIS ratio were not significant. 3) In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4) In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who bad no evidence of sacroiliitis clinically was within normal limit. 5) In 6 patients with ankylosing spondylitis in both sacroiliac joints, q whose pelvis A-P X-ray findings showed severe sclerotic change of sacroiliac pints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6) 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded the quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  16. Loop containment (joint integrity) assessment Brayton Isotope Power System flight system

    International Nuclear Information System (INIS)

    1976-01-01

    The Brayton Isotope Power System (BIPS) contains a large number of joints. Since the failure of a joint would result in loss of the working fluid and consequential failure of the BIPS, the integrity of the joints is of paramount importance. The reliability of the ERDA BIPS loop containment (joint integrity) is evaluated. The conceptual flight system as presently configured is depicted. A brief description of the flight system is given

  17. Joint Intelligence Operations Center (JIOC) Baseline Business Process Model & Capabilities Evaluation Methodology

    Science.gov (United States)

    2012-03-01

    Targeting Review Board OPLAN Operations Plan OPORD Operations Order OPSIT Operational Situation OSINT Open Source Intelligence OV...Analysis Evaluate FLTREPs MISREPs Unit Assign Assets Feedback Asset Shortfalls Multi-Int Collection Political & Embasy Law Enforcement HUMINT OSINT ...Embassy Information OSINT Manage Theater HUMINT Law Enforcement Collection Sort Requests Platform Information Agency Information M-I Collect

  18. Methodological problems of sacroiliac joint scintigraphy

    International Nuclear Information System (INIS)

    Schoerner, W.; Haubold, U.

    1981-01-01

    Bone scintigraphy of the sacroiliac joints and the lumbar spine was performed in 35 patients with ankylosing spondylitis and 30 control subjects. The scans were evaluated by qualitative and quantitative assessment. The sacroiliac/sacrum ratio (index ISG/sacrum), the sacroiliac/lumbar spine ratio (index ISG/LWS), and the left sacroiliac joint/right sacroiliac joint ratio (index li. ISG/re. ISG) were calculated. The visual interpretation of colour scans proved to be unreliable. The index ISG/sacrum was more sensitive than the index ISG/LWS. The index li. ISG/re. ISG was helpful as an additional criterion. When digital sacroiliac joint scintigraphy is well standardized it can be considered as a useful technique in early diagnosis of ankylosing spondylitis. (orig.) [de

  19. Designs and performance of three new microprocessor-controlled knee joints.

    Science.gov (United States)

    Thiele, Julius; Schöllig, Christina; Bellmann, Malte; Kraft, Marc

    2018-02-09

    A crossover design study with a small group of subjects was used to evaluate the performance of three microprocessor-controlled exoprosthetic knee joints (MPKs): C-Leg 4, Plié 3 and Rheo Knee 3. Given that the mechanical designs and control algorithms of the joints determine the user outcome, the influence of these inherent differences on the functional characteristics was investigated in this study. The knee joints were evaluated during level-ground walking at different velocities in a motion analysis laboratory. Additionally, technical analyses using patents, technical documentations and X-ray computed tomography (CT) for each knee joint were performed. The technical analyses showed that only C-Leg 4 and Rheo Knee 3 allow microprocessor-controlled adaptation of the joint resistances for different gait velocities. Furthermore, Plié 3 is not able to provide stance extension damping. The biomechanical results showed that only if a knee joint adapts flexion and extension resistances by the microprocessor all known advantages of MPKs can become apparent. But not all users may benefit from the examined functions: e.g. a good accommodation to fast walking speeds or comfortable stance phase flexion. Hence, a detailed comparison of user demands and performance of the designated knee joint is mandatory to ensure a maximum in user outcome.

  20. Temporomandibular Joint Septic Arthritis

    Directory of Open Access Journals (Sweden)

    Gianfranco Frojo, MD

    2018-01-01

    Full Text Available Summary:. Infection of the temporomandibular joint (TMJ is a rare pediatric condition resulting from the introduction of pathogens into the joint by hematogenous seeding, local extension, or trauma. Early recognition of the typical signs and symptoms including fever, trismus, preauricular swelling, and TMJ region tenderness are critical in order to initiate further evaluation and prevent feared complications of fibrosis, ankylosis, abnormal facial structure, or persistence of symptoms. Contrast-enhanced computed tomography with ancillary laboratory analysis including erythrocyte sedimentation rate, C-reactive protein, and white blood cell count are beneficial in confirming the suspected diagnosis and monitoring response to therapy. Initial intervention should include empiric parenteral antibiotics, early mandibular mobilization, and joint decompression to provide synovial fluid for analysis including cultures. This report describes a case of TMJ bacterial arthritis in a healthy 6-year-old male who was promptly treated nonsurgically with intravenous antibiotics and localized needle joint decompression with return to normal function after completion of oral antibiotics and physical therapy.

  1. Usability Evaluation of An Electronic Medication Administration Record (eMAR) Application

    Science.gov (United States)

    Guo, J.; Iribarren, S.; Kapsandoy, S.; Perri, S.; Staggers, N.

    2011-01-01

    Background Electronic medication administration records (eMARs) have been widely used in recent years. However, formal usability evaluations are not yet available for these vendor applications, especially from the perspective of nurses, the largest group of eMAR users. Objective To conduct a formal usability evaluation of an implemented eMAR. Methods Four evaluators examined a commercial vendor eMAR using heuristic evaluation techniques. The evaluators defined seven tasks typical of eMAR use and independently evaluated the application. Consensus techniques were used to obtain 100% agreement of identified usability problems and severity ratings. Findings were reviewed with 5 clinical staff nurses and the Director of Clinical Informatics who verified findings with a small group of clinical nurses. Results Evaluators found 60 usability problems categorized into 233 heuristic violations. Match, Error, and Visibility heuristics were the most frequently violated. Administer Medication and Order and Modify Medications tasks had the highest number of heuristic violations and usability problems rated as major or catastrophic. Conclusion The high number of usability problems could impact the effectiveness, efficiency and satisfaction of nurses’ medication administration activities and may include concerns about patient safety. Usability is a joint responsibility between sites and vendors. We offer a call to action for usability evaluations at all sites and eMAR application redesign as necessary to improve the user experience and promote patient safety. PMID:23616871

  2. EFSA CEF Panel (EFSA Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids) , 2016. Scientific Opinion on Flavouring Group Evaluation 90, Revision 1 (FGE.90Rev1): consideration of six substances evaluated by JECFA (68th meeting) structurally related to aliphatic, alicyclic and aromatic saturated and unsaturated tertiary alcohols, aromatic tertiary alcohols and their esters evaluated by EFSA in FGE.18Rev1 and FGE.75Rev1

    DEFF Research Database (Denmark)

    Beltoft, Vibe Meister; Nørby, Karin Kristiane

    The Panel on Food Contact Materials, Enzymes, Flavourings and Processing Aids of EFSA was requested to consider evaluations of flavouring substances assessed since 2000 by the Joint FAO/WHO Expert Committee on Food Additives (the JECFA), and to decide whether further evaluation is necessary...... refined exposure estimation and to judge whether a re-evaluation according to the Procedure is needed....

  3. Numerical and Experimental Evaluation on the Residual Stresses of Welded Joints

    Science.gov (United States)

    Huh, Sun Chul; Park, Wonjo; Yang, Haesug; Jung, Haeyoung; Kim, Chuyoung

    Wings for the defense industry such as fighters, missiles, and rockets should show no deformation or damage on the structure. The structures of existing wings had holes for weight reduction. The plates and frames were fixed with rivets or screws, which limited the weight reduction possible. In this study, an improvement was made in jointing methods through EB welding and laser welding. Welding strength was measured through tension testing. In addition, finite element analysis was performed for the welding process so as to deduce the optimum welding condition.

  4. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...... with PDUS. One MCP joint in each of 15 RA patients and 3 healthy control persons were examined with PDUS before and after intravenous bolus Levovist contrast injection. Corresponding rates of early synovial enhancement (RESE), previously shown to be closely related to histopathological synovitis, were...... calculated from dynamic contrast-enhanced MR images obtained the same day. Prior to ultrasonography, the joint was evaluated clinically. Levovist increased the flow signal in 7 of 9 joints with pre-contrast flow-signal and in 0 of 9 without pre-contrast signal. No healthy controls showed CE PDUS signal...

  5. An experimental evaluation of joint electrical resistance on power lead thermal performance

    International Nuclear Information System (INIS)

    Datskov, V.I.; Demko, J.A.; Augustynowicz, S.D.; Hutton, R.D.

    1994-01-01

    The amount of electrical resistance in braze joints is not known for certain. In addition the annealing processes that occurs during a braze or solder operation can change the residual resistivity ratio (RRR) of the copper. The change in the electrical resistivity of samples of copper because of exposure to conditions that a high current lead would see during a brazing operation were experimentally investigated. A sample was taken from a manufacturing and brazing trial of the high current power leads for the Superconducting Super Collider (SSC), and from oxygen free high conductivity copper (OFHC) 101 rod similar to that used in the trial. The samples were heated under conditions that a current lead would undergo during the brazing process. Measurements were made of the electrical resistance of the copper specimens and across a braze joint in the manufacturing trial sample for temperatures ranging from liquid helium to room temperature. A prototype of the SSC high current lead is shown. This lead was fabricated from 5 sections that were brazed together. Some results for the measured residual resistivity ratio (RRR) along this lead are given

  6. Test and evaluation about damping characteristics of hanger supports for nuclear power plant piping systems (Seismic Damping Ratio Evaluation Program)

    International Nuclear Information System (INIS)

    Shibata, H.; Ito, A.; Tanaka, K.; Niino, T.; Gotoh, N.

    1981-01-01

    Generally, damping phenomena of structures and equipments is caused by very complex energy dissipation. Especially, as piping systems are composed of many components, it is very difficult to evaluate damping characteristics of its system theoretically. On the other hand, the damping value for aseismic design of nuclear power plants is very important design factor to decide seismic response loads of structures, equipments and piping systems. The very extensive studies titled SDREP (Seismic Damping Ratio Evaluation Program) were performed to establish proper damping values for seismic design of piping as a joint work among a university, electric companies and plant makers. In SDREP, various systematic vibration tests were conducted to investigate factors which may contribute to damping characteristics of piping systems and to supplement the data of the pre-operating tests. This study is related to the component damping characteristics tests of that program. The object of this study is to clarify damping characteristics and mechanism of hanger supports used in piping systems, and to establish the evaluation technique of dispersing energy at hanger support points and its effect to the total damping ability of piping system. (orig./WL)

  7. Experimental investigations and evaluation of strength and deflections of reinforced concrete beam-column joints using nonlinear static analysis

    International Nuclear Information System (INIS)

    Sharma, Akanshu; Reddy, G.R.; Vaze, K.K.; Ghosh, A.K.; Kushwaha, H.S.

    2009-07-01

    It is now a well-known fact that beam-column connections are one of the most vulnerable zones of a reinforced concrete framed structure subjected to seismic loads. Under dynamic reversing loading, as in case of earthquakes, the inelastic hysteretic behavior of the members joining at these joints provides major contribution towards absorbing the external energy. The energy absorption capacity of a joint mainly depends on the ductility, i.e. capacity to undergo large displacements beyond yield, without significant strength degradation, of the members and the joint itself. Even if the members possess sufficient ductile behavior, the overall ductility of the joint is not warranted, until and unless the joint core itself has capacity to withstand large joint shear forces. Else, the joint core itself fails prematurely and leads to poor performance of the sub-assemblage. Another major objective of this program was to develop a simple yet effective analysis procedure that can closely predict the load-displacement behavior of the joints. Nonlinear dynamic analysis, although effective, is highly time consuming and complex. Resorting to such complex analysis is not encouraging to the practicing civil engineers or even researchers. However, as more and more emphasis is laid on nonlinear analysis and performance based design, nonlinear static pushover analysis is one such tool that is simple and effective and many researchers and engineers are getting encouraged to follow this analytical method. This report includes complete details of all the joints tested and their analysis. It gives complete theoretical formulations and assumptions used in the analysis. In the end, all the results are summarized and observations, conclusions and recommendations are made regarding the effect of various parameters on ductility of a joint. (author)

  8. 2018 NDIA 33rd Annual National Test and Evaluation Conference

    Science.gov (United States)

    2018-05-17

    funded under the Unmanned & Autonomous System Test (UAST) program to develop the “ Safe Testing of Autonomous Systems in Complex Environments ...Evaluators • Enables early verification that systems work in a Joint Environment • Test whether systems work well together • Supports all aspects of...to the Fisher House Foundation. HARASSMENT STATEMENT NDIA is committed to providing a professional environment free from physical, psychological and

  9. Accounting for CO2 variability over East Asia with a regional joint inversion system and its preliminary evaluation

    Science.gov (United States)

    Kou, Xingxia; Tian, Xiangjun; Zhang, Meigen; Peng, Zhen; Zhang, Xiaoling

    2017-10-01

    A regional surface carbon dioxide (CO2) flux inversion system, the Tan-Tracker-Region, was developed by incorporating an assimilation scheme into the Community Multiscale Air Quality (CMAQ) regional chemical transport model to resolve fine-scale CO2 variability over East Asia. The proper orthogonal decomposition-based ensemble four-dimensional variational data assimilation approach (POD-4DVar) is the core algorithm for the joint assimilation framework, and simultaneous assimilations of CO2 concentrations and surface CO2 fluxes are applied to help reduce the uncertainty in initial CO2 concentrations. A persistence dynamical model was developed to describe the evolution of the surface CO2 fluxes and help avoid the "signal-to-noise" problem; thus, CO2 fluxes could be estimated as a whole at the model grid scale, with better use of observation information. The performance of the regional inversion system was evaluated through a group of single-observation-based observing system simulation experiments (OSSEs). The results of the experiments suggest that a reliable performance of Tan-Tracker-Region is dependent on certain assimilation parameter choices, for example, an optimized window length of approximately 3 h, an ensemble size of approximately 100, and a covariance localization radius of approximately 320 km. This is probably due to the strong diurnal variation and spatial heterogeneity in the fine-scale CMAQ simulation, which could affect the performance of the regional inversion system. In addition, because all observations can be artificially obtained in OSSEs, the performance of Tan-Tracker-Region was further evaluated through different densities of the artificial observation network in different CO2 flux situations. The results indicate that more observation sites would be useful to systematically improve the estimation of CO2 concentration and flux in large areas over the model domain. The work presented here forms a foundation for future research in which a

  10. Experimental evaluation of indoor magnetic distortion effects on gait analysis performed with wearable inertial sensors

    International Nuclear Information System (INIS)

    Palermo, E; Patanè, F; Cappa, P; Rossi, S

    2014-01-01

    Magnetic inertial measurement unit systems (MIMU) offer the potential to perform joint kinematics evaluation as an alternative to optoelectronic systems (OS). Several studies have reported the effect of indoor magnetic field disturbances on the MIMU's heading output, even though the overall effect on the evaluation of lower limb joint kinematics is not yet fully explored. The aim of the study is to assess the influence of indoor magnetic field distortion on gait analysis trials conducted with a commercial MIMU system. A healthy adult performed gait analysis sessions both indoors and outdoors. Data collected indoors were post-processed with and without a heading correction methodology performed with OS at the start of the gait trial. The performance of the MIMU system is characterized in terms of indices, based on the mean value of lower limb joint angles and the associated ROM, quantifying the system repeatability. We find that the effects of magnetic field distortion, such as the one we experienced in our lab, were limited to the transverse plane of each joint and to the frontal plane of the ankle. Sagittal plane values, instead, showed sufficient repeatability moving from outdoors to indoors. Our findings provide indications to clinicians on MIMU performance in the measurement of lower limb kinematics. (paper)

  11. Radiologic Study of Meniscus Perforations in the Temporomandibular Joint

    International Nuclear Information System (INIS)

    Kim, Kee Duck; Park, Chang Seo

    1990-01-01

    Thirty-nine patients (forty-four joints) who had been diagnosed as having meniscus perforation of the temporomandibular joint by inferior joint space arthrography and had been treated by surgical procedures were evaluated retrospectively. Information of clinical findings, arthrotomographic findings and surgical findings was collected on a standardized form and evaluated. The results were as follows: 1. On the 34 patients of 38 joints which were surgically confirmed perforation of meniscus or its attachments of the temporomandibular joint, there were 29 females and 5 males (5.8:1). The average age was 36 years (range 17 to 70). 2. The common clinical findings of group that had meniscus displacement without reduction and with perforation were pain on the affected joint and limitation of mouth opening. In the group showing meniscus displacement with reduction and with perforation the common clinical findings were pain and clicking on the affected joint. 3. 32 joints (84.2%) were arthrotomographically anterior meniscus displacement without reduction and with perforation, 6 joints (15.8%) showed anterior meniscus displacement with reduction and with perforation. 4. Joints categorized arthrotomographically as having meniscus displacement without reduction and with perforation were less likely to have full translation of the condyle in comparison with the normal or meniscus displacement with reduction and with perforation groups (p<0.05) 5. The arthrographic findings of 44 joints having meniscus perforation were compared with surgical findings, there were 6 false positive findings of meniscus perforation, the reliability of arthrographic findings of meniscus perforation was a 86.4% correlation with surgical findings. 6. On the site of perforations of 38 joints which were surgically confirmed perforation of meniscus or its attachments, twenty-three of perforations (60.5%) were in location at the junction of the meniscus and posterior attachment, fourteen (36.9%) were

  12. Pose Estimation with a Kinect for Ergonomic Studies: Evaluation of the Accuracy Using a Virtual Mannequin

    Directory of Open Access Journals (Sweden)

    Pierre Plantard

    2015-01-01

    Full Text Available Analyzing human poses with a Kinect is a promising method to evaluate potentials risks of musculoskeletal disorders at workstations. In ecological situations, complex 3D poses and constraints imposed by the environment make it difficult to obtain reliable kinematic information. Thus, being able to predict the potential accuracy of the measurement for such complex 3D poses and sensor placements is challenging in classical experimental setups. To tackle this problem, we propose a new evaluation method based on a virtual mannequin. In this study, we apply this method to the evaluation of joint positions (shoulder, elbow, and wrist, joint angles (shoulder and elbow, and the corresponding RULA (a popular ergonomics assessment grid upper-limb score for a large set of poses and sensor placements. Thanks to this evaluation method, more than 500,000 configurations have been automatically tested, which would be almost impossible to evaluate with classical protocols. The results show that the kinematic information obtained by the Kinect software is generally accurate enough to fill in ergonomic assessment grids. However inaccuracy strongly increases for some specific poses and sensor positions. Using this evaluation method enabled us to report configurations that could lead to these high inaccuracies. As a supplementary material, we provide a software tool to help designers to evaluate the expected accuracy of this sensor for a set of upper-limb configurations. Results obtained with the virtual mannequin are in accordance with those obtained from a real subject for a limited set of poses and sensor placements.

  13. Development of life evaluation technology for nuclear power plant components

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin [Sungkyunkwan Univ., Seoul (Korea, Republic of); Kwon, J. D. [Yeungnam Univ., Gyeongsan (Korea, Republic of); Kang, K. J. [Chonnam National Univ., Gwangju (Korea, Republic of)] (and others)

    2001-03-15

    This research focuses on development of reliable life evaluation technology for nuclear power plant (NPP) components, and is divided into two parts, development of life evaluation systems for pressurized components and evaluation of applicability of emerging technology to operating plants. For the development of life evaluation system for nuclear pressure vessels, the following seven topics are covered: development of expert systems for integrity assessment of pressurized components, development of integrity evaluation systems of steam generator tubes, prediction of failure probability for NPP components based on probabilistic fracture mechanics, development of fatigue damage evaluation technique for plant life extension, domestic round robin analysis for pressurized thermal shock of reactor vessels, domestic round robin analysis of constructing P--T limit curves for reactor vessels, and development of data base for integrity assessment. For evaluation of applicability of emerging technology to operating plants, on the other hand, the following eight topics are covered: applicability of the Leak-Before-Break analysis to Cast S/S piping, collection of aged material tensile and toughness data for aged Cast S/S piping, finite element analyses for load carrying capacity of corroded pipes, development of Risk-based ISI methodology for nuclear piping, collection of toughness data for integrity assessment of bi-metallic joints, applicability of the Master curve concept to reactor vessel integrity assessment, measurement of dynamic fracture toughness, and provision of information related to regulation and plant life extension issues.

  14. Long-term clinical results in patients treated for recurrent posterolateral elbow joint instability using an ipsilateral triceps tendon graft

    DEFF Research Database (Denmark)

    Kastenskov, Christian; Rasmussen, Jeppe Vejlgaard; Ovesen, Janne

    2017-01-01

    version of Oxford Elbow Score. Furthermore, conventional anteroposterior and side-view radiographs of the elbow were obtained to evaluate osteoarthritis, calcifications in the ligaments, and joint subluxation. We evaluated the radiographs by the size of osteophytes, joint space narrowing, and subchondral...

  15. Prevalence of Concomitant Sacroiliac joint Dysfunction in Patients With Image Proven Herniated Lumbar Discs

    Directory of Open Access Journals (Sweden)

    Salah Alalawi

    2009-05-01

    Full Text Available Background:Sacroiliac joint (SIJ dysfunction is a widely known but poorly defined cause of low back pain. To our knowledge, few published studies have been conducted to evaluate systematically the prevalence and significance of concomitant sacroiliac joint dysfunction in patients with herniated lumbar discs. As concomitant SIJ dysfunction in low back pain patients is likely to respond to particular noninvasive interventions such as manipulation,improved understanding of the relationship between these two diagnoses would improve clinical decision making and research.Methods:This study was designated to estimate the prevalence of concomitant sacroiliac joint dysfunction in sub acute low back pain patients with image proven discopathy and evaluate the theory that sacroiliac joint dysfunction can be a source of pain and functional disability in discopathy. A total of 202 patients with sub acute radicular back pain and MRI proven herniated lumbar discs underwent standardized   physiatrist history and physical examination, specified for detection of concomitant sacroiliac joint dysfunction.Results: Sacroiliac joint dysfunction is a concomitant finding in 72.3% of evaluated patients.There was significantly higher SIJ dysfunction prevalence in female patients (p <0.0001. Conclusion: SIJ dysfunction is a significant pathogenic factor with high possibility of occurrence in low back pain. Thus, in the presence of radicular and sacroiliac joint symptoms, SIJ dysfunction, regardless of intervertebral disc pathology, must be considered in clinical decisiomaking.

  16. Evaluation of chondrocalcinosis and associated knee joint degeneration using MR imaging: Data from the osteoarthritis initiative

    Energy Technology Data Exchange (ETDEWEB)

    Gersing, Alexandra S.; Schwaiger, Benedikt J.; Heilmeier, Ursula; Joseph, Gabby B.; Facchetti, Luca; Kretzschmar, Martin; Steinbach, Lynne S.; Link, Thomas M. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Lynch, John A.; McCulloch, Charles E.; Nevitt, Michael C. [University of California, San Francisco, Department of Epidemiology and Biostatistics, San Francisco, CA (United States)

    2017-06-15

    To evaluate the ability of different MRI sequences to detect chondrocalcinosis within knee cartilage and menisci, and to analyze the association with joint degeneration. Subjects with radiographic knee chondrocalcinosis (n = 90, age 67.7 ± 7.3 years, 50 women) were selected from the Osteoarthritis Initiative and matched to controls without radiographic chondrocalcinosis (n = 90). Visualization of calcium-containing crystals (CaC) was compared between 3D T1-weighted gradient-echo (T1GE), 3D dual echo steady-state (DESS), 2D intermediate-weighted (IW), and proton density (PD)-weighted fast spin-echo (FSE) sequences obtained with 3T MRI and correlated with a semiquantitative CaC score obtained from radiographs. Structural abnormalities were assessed using Whole-Organ MRI Score (WORMS) and logistic regression models were used to compare cartilage compartments with and without CaC. Correlations between CaC counts of MRI sequences and degree of radiographic calcifications were highest for GE (r{sub T1GE} = 0.73, P < 0.001; r{sub DESS} = 0.68, P < 0.001) compared to other sequences (P > 0.05). Meniscus WORMS was significantly higher in subjects with chondrocalcinosis compared to controls (P = 0.005). Cartilage defects were significantly more frequent in compartments with CaC than without (patella: P = 0.006; lateral tibia: P < 0.001; lateral femur condyle: P = 0.017). Gradient-echo sequences were most useful for the detection of chondrocalcinosis and presence of CaC was associated with higher prevalence of cartilage and meniscal damage. (orig.)

  17. Effect of Shielding Gas on the Properties of AW 5083 Aluminum Alloy Laser Weld Joints

    Science.gov (United States)

    Vyskoč, Maroš; Sahul, Miroslav; Sahul, Martin

    2018-04-01

    The paper deals with the evaluation of the shielding gas influence on the properties of AW 5083 aluminum alloy weld joints produced with disk laser. Butt weld joints were produced under different shielding gas types, namely Ar, He, Ar + 5 vol.% He, Ar + 30 vol.% He and without shielding weld pool. Light and electron microscopy, computed tomography, microhardness measurements and tensile testing were used for evaluation of weld joint properties. He-shielded weld joints were the narrowest ones. On the other hand, Ar-shielded weld joints exhibited largest weld width. The choice of shielding gas had significant influence on the porosity level of welds. The lowest porosity was observed in weld joint produced in Ar with the addition of 5 vol.% He shielding atmosphere (only 0.03%), while the highest level of porosity was detected in weld joint produced in pure He (0.24%). Except unshielded aluminum alloy weld joint, the lowest tensile strength was recorded in He-shielded weld joints. On the contrary, the highest average microhardness was measured in He-shielded weld joints.

  18. Immersion hand radiography in the evaluation of musculoskeletal disorders

    International Nuclear Information System (INIS)

    Ngo, C.; Yaghmai, I.; Zach, R.

    1987-01-01

    A prospective study is undertaken to evaluate a new soft-tissue immersion technique. The hand is immersed in a plastic tray containing a mixture solution of alcohol and water. Exposures are made employing low-kilovolt technique. Conventional x-rays of the hands are obtained to serve as baseline studies and for the purpose of comparison. Soft-tissue immersion technique has proven sensitive and efficient in outlining the skin, subcutaneous fat layers, and fat layers between muscle planes. More importantly, the tendons and the joint capsules, which are hardly seen on standard hand radiographs, are easily highlighted with this technique. In conclusion, this technique appears to be superior to conventional plain radiographs in the evaluation and early detection of soft-tissue changes related to musculoskeletal disorders, especially in cases of arthritides

  19. Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    Science.gov (United States)

    Karimi, Mohammad Taghi; Mohammadi, Ali; Ebrahimi, Mohammad Hossein; McGarry, Anthony

    2017-02-01

    The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influence of these factors on deformation of the femoral head. Two subjects with LCPD participated in this study. Subject motion and the forces applied on the affected leg were recorded using a motion analysis system (Qualsis TM ) and a Kistler force plate. OpenSim software was used to determine joint contact force of the hip joint whilst walking with and without a Scottish Rite orthosis. 3D Models of hip joints of both subjects were produced by Mimics software. The deformation of femoral bone was determined by Abaqus. Mean values of the force applied on the leg increased while walking with the orthosis. There was no difference between bone mineral density (BMD) of the femoral bone of normal and LCPD sides (p-value>0.05) and no difference between hip joint contact force of normal and LCPD sides. Hip joint containment appeared to decrease follow the use of the orthosis. It can be concluded that the deformation of femoral head in LCPD may not be due to change in BMD or applied load. Although the Scottish Rite orthosis is used mostly to increase hip joint containment, it appears to reduce hip joint contact area. It is recommended that a similar study is conducted using a higher number of subjects. Copyright © 2016 IPEM. All rights reserved.

  20. Empowerment Evaluation: A Form of Self-Evaluation.

    Science.gov (United States)

    Fetterman, David M.

    Empowerment evaluation is an innovative approach that uses evaluation concepts and techniques to foster improvement and self-determination. Empowerment evaluation employs qualitative and quantitative methodologies. Although it can be applied to individuals and organizations, the usual focus is on programs. The value orientation of empowerment…

  1. Development and evaluation of low-cost walker with trunk support for senior citizen.

    Science.gov (United States)

    Poier, Paloma Hohmann; Godke, Francisco; Foggiatto, José Aguiomar; Ulbricht, Leandra

    2017-10-09

    Develop and evaluate a low-cost walker with trunk support for senior citizens. Two-stage descriptive study: development of a walker with trunk support and evaluation with fourth age senior citizens. Twenty-three fourth age senior citizens were selected. The evaluated criteria were the immediate influence of the walker on the static stabilometry with baropodometer and the evaluation of gait with accelerometers monitoring time and amplitude of the hip movement. There was a significant decrease in the body oscillation of senior citizens with the use of the developed walker, and there were changes in the joint amplitudes of the hip, but they were not significant. Using low-cost materials, it was possible to develop and equipment that met resistance and effectiveness requirements. The walker interfered in the balance of the senior citizens, reducing significantly the static body oscillation.

  2. Fundamental studies on electron-beam welding of heat-resistant superalloys for nuclear plants: Report 4. Mechanical properties of welded joints

    International Nuclear Information System (INIS)

    Susei, S.; Shimizu, S.; Aota, T.

    1982-04-01

    In this report, electron-beam (EB) welded joints and TIG welded joints of various superalloys to be used for nuclear plants, such as Hastelloy-type, Inconel-type and Incoloy-type, are systematically evaluated in terms of tensile properties, low-cycle fatigue properties at elevated temperatures, creep and creep-rupture properties. It was fully confirmed as conclusion that the EB welded joints are superior to the TIG welded ones in mechanical properties, especially at high temperature. In the evaluation of creep properties, ductility is one of the most important criteria to represent the resistance against fracture due to creep deformation, and this criterion is very useful in evaluating the properties of welded joints. Therefore, the more comparable to the base metal the electron beam welded joint becomes in terms of ductility, the more resistant is it against fracture. From this point of view, the electron beam welded joint is considerably superior to the TIG welded joint [fr

  3. Hydrogen and Fuel Cell Transit Bus Evaluations : Joint Evaluation Plan for the U.S. Department of Energy and the Federal Transit Administration

    Science.gov (United States)

    2008-05-01

    This document describes the hydrogen transit bus evaluations performed by the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) and the U.S. Department of Transportations Federal Transit Administration (...

  4. What role do plain radiographs have in assessing the skeletally immature acromioclavicular joint?

    Science.gov (United States)

    Lee, Seung Yeol; Kwon, Soon-Sun; Chung, Chin Youb; Lee, Kyoung Min; Park, Moon Seok

    2014-01-01

    Because of incomplete ossification of the coracoid process and acromion, acromioclavicular joint configuration in the skeletally immature patient differs from that of adults. Although comparison to radiographic standards for this joint is critical in the evaluation of acromioclavicular joint injuries, these standards are not well defined for children or adolescents. We therefore sought to determine (1) the reliability of numerous radiographic measurements of the skeletally immature acromioclavicular joint, including the vertical and shortest coracoclavicular interval, and the acromioclavicular joint offset; (2) the timing of ossification of the acromion and coracoid in males and females; and (3) the differences in the values of these radiographic measurements based on age and sex. This study was based on a total of 485 subjects, 8 to 18 years old, who underwent conventional AP view radiographs of both shoulders. The 485 subjects were included to assess normal configuration around the acromioclavicular joint and 466 of these subjects were evaluated for comparison between both sides. The vertical and shortest coracoclavicular interval, coracoclavicular clavicle width ratio, acromioclavicular joint offset, and difference of the coracoclavicular interval of both sides were measured. A reliability test was conducted before obtaining the main measurements. The relationship of measurements with sex, age, and stage of ossification was evaluated. The vertical and shortest coracoclavicular interval showed excellent reliability (intraclass correlation coefficient ([ICC], 0.918 and 0.934). The acromioclavicular joint offset showed low reliability (ICC, 0.543). The ossification centers of the acromion and the coracoid processes appeared and fused earlier in females than in males. The vertical coracoclavicular interval, which was not affected by partial ossification of the coracoid process, was less than 11 mm in the 90% quantile of total subjects in males and 10 mm in the 90

  5. An Accelerated Testing Approach for Automated Vehicles with Background Traffic Described by Joint Distributions

    OpenAIRE

    Huang, Zhiyuan; Lam, Henry; Zhao, Ding

    2017-01-01

    This paper proposes a new framework based on joint statistical models for evaluating risks of automated vehicles in a naturalistic driving environment. The previous studies on the Accelerated Evaluation for automated vehicles are extended from multi-independent-variate models to joint statistics. The proposed toolkit includes exploration of the rare event (e.g. crash) sets and construction of accelerated distributions for Gaussian Mixture models using Importance Sampling techniques. Furthermo...

  6. Sensory evaluation of gluten-free quinoa whole grain snacks

    OpenAIRE

    Kahlon, Talwinder S.; Avena-Bustillos, Roberto J.; Chiu, Mei-Chen M.

    2016-01-01

    Sensory evaluation of quinoa gluten-free whole grain low fat and salt snacks was conducted. The snacks were Quinoa, Quinoa-Cayenne Pepper, Quinoa-Ginger and Quinoa-Turmeric. Cayenne pepper, ginger and turmeric are common spices that contain health promoting nutrients. Cayenne pepper has been associated with enhancing heat production. Ginger has been reported to improve blood flow and prevent joint pains. Turmeric has been observed to have wound healing potential. All the snacks contained 6% c...

  7. Magnetic resonance imaging evaluation of cruciate ligaments after arthroscopic reconstruction

    Directory of Open Access Journals (Sweden)

    Amit Kharat

    2017-01-01

    Full Text Available Background: Due to increase in road traffic and sports injuries, tears of anterior cruciate ligament (ACL and the posterior cruciate ligament (PCL of the knee are common. Magnetic resonance imaging (MRI is emerging as an important tool of diagnosis and evaluation of these injuries. Methods: We carried out a prospective study on role of MRI on ten patients who had undergone ACL or PCL repair over a period of six months. In this report we present three illustrative cases to capture the spectrum of findings in our series to underline the role of MRI in management of such injuries and discuss the modalities of the procedure. Results: In our series, as demonstrated by the cases, MRI had an important role in diagnosis and evaluation of injuries to the cruciate ligaments. Conclusion: MRI can play an important role, particularly in tertiary centres, in diagnosis and evaluation of reconstructed ACL and PCL ligaments of the knee joint.

  8. Metallographic observations of AISI 304 - copper dissimular joints

    International Nuclear Information System (INIS)

    Medeiros, R.C. de; Carvalho Perdigao, S. de

    1982-01-01

    The current work informs on the SMAW dissimilar joints embrittled by molten Copper. Bead on plate of that metal were deposited on four different base metals to evaluate the phenomena. Conventional and non conventional welding methods were employed to obtain dissimilar joints of AISI 304-Cu. The latter were observed metallographically. These results are to be complemented by mechanical testing actually being performed. (Author) [pt

  9. The possibility of the radiological and ultrasonographic examination of the facet joints of the equine thoracic and lumbar spine

    International Nuclear Information System (INIS)

    Reisinger, R.

    2003-03-01

    The facet joints of the equine thoracic and lumbar spine were examined by radiology and ultrasonography in 31 and 20 standing horses, respectively. The employed methods were evaluated. The left and right joints of 15/31 standing horses were comparatively x-rayed with both 20 o ventral oblique and 30 o dorsal oblique techniques. The independent evaluation of the ensuing films by four experienced veterinary surgeons yielded a significantly better assessment of the tested parameters in the 20 o ventral oblique technique. It was possible to depict the facet joints of the right and left sides between the caudal margin of the scapula and the diaphragm with the pulmonary field as background rich in contrast. In 20 horses, the facet joints were examined from Th10 to L6 in longitudinal and sagittal planes. A linear-array ultrasound probe with a frequency of 7,5 MHz and a convex ultrasound probe with a frequency of 3,5 MHz were used. Depending on the nutritional state, the soft tissue structures could be evaluated. The evaluation of the facet joints themselves was very limited. (author)

  10. Cauda equina syndrome in the dog: radiographic evaluation

    International Nuclear Information System (INIS)

    Morgan, J.P.; Bailey, C.S.

    1990-01-01

    Dogs with clinical signs typical of cauda equina syndrome require careful evaluation to determine the cause of the disease as this strongly influences choice of treatment. Possible aetiologies include congenital or developmental, inflammatory, traumatic, neoplastic, and degenerative lesions that may involve vertebrae, vertebral joints, intervertebral discs, spinal cord, spinal nerves, or meninges. It must be determined whether clinical signs are due to musculoskeletal or neurological disease before performing special radiographic procedures. Non-contrast radiography permits false-positive diagnosis of obvious degenerative changes involving the L-S disc that may be without clinical signs or permits a false-negative diagnosis due to the failure to appreciate soft tissue lesions not seen radiographically. Special radiographic techniques are recommended and include: (1) stress radiography, (2) discography, and (3) epidural myelography. Evaluation of the results of these studies assists in determining the cause of the cauda equina syndrome and the type of therapy required

  11. American Evaluation Association: Guiding Principles for Evaluators

    Science.gov (United States)

    American Journal of Evaluation, 2009

    2009-01-01

    The American Evaluation Association (AEA) strives to promote ethical practice in the evaluation of programs, products, personnel, and policy. This article presents the list of principles which AEA developed to guide evaluators in their professional practice. These principles are: (1) Systematic Inquiry; (2) Competence; (3) Integrity/Honesty; (4)…

  12. JEF-2. The evaluated Nuclear Data Library of the NEA Data Bank

    International Nuclear Information System (INIS)

    Lemmel, H.D.; Schwerer, O.

    1993-01-01

    This document summarizes the contents of JEF-2, the Joint Evaluated File of nuclear data compiled by the OECD Nuclear Energy Agency Data Bank, finalized in 1992 and released in 1993. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  13. JEF-1: The Evaluated Nuclear Data Library of the NEA Data Bank

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1991-04-01

    This document summarizes the contents of JEF-1, the Joint Evaluated File of nuclear data compiled by the OECD Nuclear Energy Agency Data Bank, finalized in 1986 and released in 1990. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  14. JEF-1. The evaluated nuclear data library of the NEA Data Bank

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1990-09-01

    This document summarizes the contents of JEF-1, the Joint Evaluated File of nuclear data compiled by the OECD Nuclear Energy Agency Data Bank, finalized in 1986 and released in 1990. The entire library or retrievals of selected materials are available on magnetic tape from the IAEA Nuclear Data Section free of charge. (author)

  15. Neuromuscular prehabilitation to prevent osteoarthritis after a traumatic joint injury.

    Science.gov (United States)

    Tenforde, Adam S; Shull, Pete B; Fredericson, Michael

    2012-05-01

    Post-traumatic osteoarthritis (PTOA) is a process resulting from direct forces applied to a joint that cause injury and degenerative changes. An estimated 12% of all symptomatic osteoarthritis (OA) of the hip, knee, and ankle can be attributed to a post-traumatic cause. Neuromuscular prehabilitation is the process of improving neuromuscular function to prevent development of PTOA after an initial traumatic joint injury. Prehabilitation strategies include restoration of normative movement patterns that have been altered as the result of traumatic injury, along with neuromuscular exercises and gait retraining to prevent the development of OA after an injury occurs. A review of the current literature shows that no studies have been performed to evaluate methods of neuromuscular prehabilitation to prevent PTOA after a joint injury. Instead, current research has focused on management strategies after knee injuries, the value of exercise in the management of OA, and neuromuscular exercises after total knee arthroplasty. Recent work in gait retraining that alters knee joint loading holds promise for preventing the development of PTOA after joint trauma. Future research should evaluate methods of neuromuscular prehabilitation strategies in relationship to the outcome of PTOA after joint injury. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. Automatic Quantification of Radiographic Wrist Joint Space Width of Patients With Rheumatoid Arthritis.

    Science.gov (United States)

    Huo, Yinghe; Vincken, Koen L; van der Heijde, Desiree; de Hair, Maria J H; Lafeber, Floris P; Viergever, Max A

    2017-11-01

    Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints are located around the scaphoid bone, viz. the multangular-navicular, capitate-navicular-lunate, and radiocarpal joints. Methods: The joint space around the scaphoid bone is detected by using consecutive searches of separate path segments, where each segment location aids in constraining the subsequent one. For joint margin delineation, first the boundary not affected by X-ray projection is extracted, followed by a backtrace process to obtain the actual joint margin. The accuracy of the quantified JSW is evaluated by comparison with the manually obtained ground truth. Results: Two of the 50 radiographs used for evaluation of the method did not yield a correct path through all three wrist joints. The delineated joint margins of the remaining 48 radiographs were used for JSW quantification. It was found that 90% of the joints had a JSW deviating less than 20% from the mean JSW of manual indications, with the mean JSW error less than 10%. Conclusion: The proposed method is able to automatically quantify the JSW of radiographic wrist joints reliably. The proposed method may aid clinical researchers to study the progression of wrist joint damage in RA studies. Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints

  17. Dynamic 3 T MRI of temporomandibular joint in diagnosing a stuck disk

    Directory of Open Access Journals (Sweden)

    J Sureka

    2012-01-01

    Full Text Available Magnetic resonance imaging (MRI is the imaging modality of choice in the evaluation of internal derangement of the temporomandibular joint (TMJ. Dynamic MRI including the open and close mouth views in sagittal plane determine the exact position of articular disk and thus help to evaluate the joint for internal derangement. We also highlight the role of dynamic MRI of TMJ in diagnosis of stuck disk in a 17-year-old male who presented with symptoms of pain and difficulty in opening the mouth.

  18. Anatomical predisposition of the ankle joint for lateral sprain or lateral malleolar fracture evaluated by radiographic measurements.

    Science.gov (United States)

    Lee, Kyoung Min; Chung, Chin Youb; Sung, Ki Hyuk; Lee, SeungYeol; Kim, Tae Gyun; Choi, Young; Jung, Ki Jin; Kim, Yeon Ho; Koo, Seung Bum; Park, Moon Seok

    2015-01-01

    Injury mechanism and the amount of force are important factors determining whether a fracture or sprain occurs at the time of an ankle inversion injury. However, the anatomical differences between the ankle fracture and sprain have not been investigated sufficiently. This study was performed to investigate whether an anatomical predisposition of the ankle joint results in a lateral malleolar fracture or lateral ankle sprain. Two groups of consecutive patients, one with lateral malleolar fracture (274 patients, mean age 49.0 years) and the other with lateral ankle sprain (400 patients, mean age 38.4 years), were evaluated. Ankle radiographs were examined for 7 measures: distal tibial articular surface (DTAS) angle, bimalleolar tilt (BT), medial malleolar relative length (MMRL), lateral malleolar relative length (LMRL), medial malleolar slip angle (MMSA), anterior inclination of tibia (AI), and fibular position (FP). After an interobserver reliability test, the radiographic measurements were compared between the 2 groups. Linear regression analysis was performed to correct for age and sex effects between the groups. The fracture group and the sprain group showed significant differences in BT (P = .001), MMSA (P sprain groups showed a significant difference in BT (P = .001), MMRL (P ankle sprain group. Further 3-dimensional assessment of the bony structure and subsequent biomechanical studies are needed to elucidate the mechanism of injury according to the various types of ankle fractures and ankle sprain. Level III, retrospective comparative study. © The Author(s) 2014.

  19. Fracture line index of fibular stalk and the ankle joint bone in the classification of the ankle joint trauma

    International Nuclear Information System (INIS)

    Wu Jun; Zhang Qiang

    2003-01-01

    Objective: To evaluate the fracture line index of fibular stalk and the ankle joint bone in the classification of the ankle joint trauma. Methods: Measure fracture line index of fibular stalk and the ankle joint in 217 adult cases of fracture and dislocation of ankle joint. And the cases were classified by the results of the measurement. Results: Measurement was unavailable in 9 cases of tearing fracture. In 31 cases, the lesions could not be particularly classified. And in the rest 176 cases the trauma were precisely classified. The over all successful rate was 81.6%. Conclusion: Fracture line index of fibular stalk and the ankle joint bone are valuable in classification of the trauma of the angle joint. While the specificity of this method is low in differentiating the adducting and abducting fracture of the medial angle, in which a combined investigation is recommended

  20. Impact of extra-articular pathologies on groin pain: An arthroscopic evaluation.

    Directory of Open Access Journals (Sweden)

    Mitsunori Kaya

    Full Text Available For patients who have anterior hip pain evaluated by Patrick's test and tenderness at Scarpa's triangle, we perform periarticular debridement based on the hypothesis that extra-articular pathologies are responsible for the hip pain. The purpose of this study was to categorize the endoscopic extra-articular findings and to evaluate the clinical significance of periarticular pathologies in anterior hip pain.Arthroscopic findings of 77 patients who underwent periarthritic debridement were evaluated. As extra-articular pathologies, injuries of the direct head and reflective head of the rectus femoris muscle were evaluated. A thin layer of fat tissue normally exists on the anterior inferior iliac spine (AIIS, the attachment site of the direct head of the rectus femoris muscle. The macroscopic appearance of the fat pad on the AIIS was categorized as normal, blood vessel-rich adipose tissue or adipose tissue with fibrosis or scar formation and histologically confirmed. Adhesion of gluteal muscles to the joint capsule was also evaluated.Of the 77 patients, 75 had rupture of the direct head of the rectus femoris. In contrast, rupture of the reflective head was extremely rare. Seven patients had a normal fat pad on the AIIS, 11 had blood vessel-rich adipose tissue and 55 had adipose tissue with fibrosis. Fat tissue was completely replaced by fibrous scar tissue in another 4 patients. In 64 patients, adhesion between the anterior joint capsule and gluteus muscles was marked. Groin pain disappeared soon after the operation even when labral tears were not repaired and all patients returned to daily life and sports activities within 2 weeks after operation.Rectus femoris tendinosis, fibrosis of the AIIS fat pad, and adhesion of gluteal and rectus femoris muscles are common extra-articular pathologies in patients with anterior hip pain. Management of only these lesions induces rapid relief of anterior hip pain even in the absence of labral tear repair. My

  1. Impact of extra-articular pathologies on groin pain: An arthroscopic evaluation.

    Science.gov (United States)

    Kaya, Mitsunori

    2018-01-01

    For patients who have anterior hip pain evaluated by Patrick's test and tenderness at Scarpa's triangle, we perform periarticular debridement based on the hypothesis that extra-articular pathologies are responsible for the hip pain. The purpose of this study was to categorize the endoscopic extra-articular findings and to evaluate the clinical significance of periarticular pathologies in anterior hip pain. Arthroscopic findings of 77 patients who underwent periarthritic debridement were evaluated. As extra-articular pathologies, injuries of the direct head and reflective head of the rectus femoris muscle were evaluated. A thin layer of fat tissue normally exists on the anterior inferior iliac spine (AIIS), the attachment site of the direct head of the rectus femoris muscle. The macroscopic appearance of the fat pad on the AIIS was categorized as normal, blood vessel-rich adipose tissue or adipose tissue with fibrosis or scar formation and histologically confirmed. Adhesion of gluteal muscles to the joint capsule was also evaluated. Of the 77 patients, 75 had rupture of the direct head of the rectus femoris. In contrast, rupture of the reflective head was extremely rare. Seven patients had a normal fat pad on the AIIS, 11 had blood vessel-rich adipose tissue and 55 had adipose tissue with fibrosis. Fat tissue was completely replaced by fibrous scar tissue in another 4 patients. In 64 patients, adhesion between the anterior joint capsule and gluteus muscles was marked. Groin pain disappeared soon after the operation even when labral tears were not repaired and all patients returned to daily life and sports activities within 2 weeks after operation. Rectus femoris tendinosis, fibrosis of the AIIS fat pad, and adhesion of gluteal and rectus femoris muscles are common extra-articular pathologies in patients with anterior hip pain. Management of only these lesions induces rapid relief of anterior hip pain even in the absence of labral tear repair. My observations suggest

  2. [Staple fixation for the treatment of hamate metacarpal joint injury].

    Science.gov (United States)

    Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da

    2014-03-01

    To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.

  3. Operative treatment of acromioclavicular joint dislocation: a new technique with suture anchors

    Directory of Open Access Journals (Sweden)

    Zhang Jingwei

    2014-07-01

    Full Text Available 【Abstract】Objective: To evaluate clinical outcome of suture anchors in strengthening both acromioclavicular and coracoclavicular ligaments in the surgical treatment of acromioclavicular joint dislocation. Methods: Twenty-eight patients with acute traumatic Rockwood III, IV and V dislocations of the acromioclavicular joint surgically treated at our institute between October 2010 and January 2012 were recruited. All patients underwent open reduction combined with suture anchors. Function was evaluated using the ConstantMurley shoulder score. Clinical and radiographic shoulder ratings were evaluated using Taft criteria at 3, 6 and 12 months. Results:Two cases with fixation loosening were not included in final statistical analysis. Other patients obtained full joint reposition on immediate postoperative radiographs. Follow-up was performed with an average of 15.6 months (range, 12-19. After early range of motion exercises, 96.2% of the patients (25/26 could abduct and elevate their shoulders more than 90 degrees within postoperative 3 months. There was no infection. Average Constant-Murley score was 96.3 points (range, 94-100 and mean Taft shoulder rating was 10.7 points (range, 8-12 at 12 months. Conclusion: The suture anchor is a relatively simple technique and can avoid screw removal which is helpful in reconstructing both acromioclavicular and coracoclavicular ligaments in acute traumatic acromioclavicular joint dislocation. Key words: Acromioclavicular joint; Dislocations; Surgery; Suture anchors

  4. Automatic evaluation of radiographs with the REBUS system

    International Nuclear Information System (INIS)

    Keck, R.; Coen, G.

    1987-01-01

    Digital image processing has become a top rank quality assurance method in industry in the last few years, and still promises improvements in future. One of the main reasons of this development is the fact that for specific applications, digital image processing has matured from simple image processing (deletion of unimportant marginal data, edge detection, signal-to-noise improvement) to automatic image evaluation. As an example of such specific applications, the article explains the detection and classification of flows in welded seams or joints by means of radiographic testing. (orig./HP) [de

  5. Modifying Formative Evaluation Techniques For Distance Education Class Evaluation

    Directory of Open Access Journals (Sweden)

    Scott L. WALKER

    2005-10-01

    Full Text Available Modifying Formative Evaluation Techniques For Distance Education Class Evaluation Assistant Professor Scott L. WALKERDepartment of GeographyTexas State UniversitySan Marcos, USA ABSTRACTPost-secondary classes are usually followed by mandatory summative evaluations, yet changes in teaching and course structure cannot be made with summative evaluations. Formative evaluations in online education can result in candid responses from students if a third-party facilitator is involved in the process. This paper presents a method for conducting formative evaluation in an online class by utilizing the assistance of a colleague. Results of one such evaluation are presented, as are its advantages and disadvantages.

  6. Quality Assurance in E-Learning: PDPP Evaluation Model and its Application

    Directory of Open Access Journals (Sweden)

    Weiyuan Zhang

    2012-06-01

    Full Text Available E-learning has become an increasingly important teaching and learning mode in educational institutions and corporate training. The evaluation of e-learning, however, is essential for the quality assurance of e-learning courses. This paper constructs a four-phase evaluation model for e-learning courses, which includes planning, development, process, and product evaluation, called the PDPP evaluation model. Planning evaluation includes market demand, feasibility, target student group, course objectives, and finance. Development evaluation includes instructional design, course material design, course Web site design, flexibility, student-student interaction, teacher/tutor support, technical support, and assessment. Process evaluation includes technical support, Web site utilization, learning interaction, learning evaluation, learning support, and flexibility. Product evaluation includes student satisfaction, teaching effectiveness, learning effectiveness, and sustainability. Using the PDPP model as a research framework, a purely e-learning course on Research Methods in Distance Education, developed by the School of Professional and Continuing Education at the University of Hong Kong (HKU SPACE and jointly offered with the School of Distance Learning for Medical Education of Peking University (SDLME, PKU, was used as a case study. Sixty students from mainland China, Hong Kong, Macau, and Malaysia were recruited for this course. According to summative evaluation through a student e-learning experience survey, the majority of students were very satisfied/satisfied on all e-learning dimensions of this course. The majority of students thought that the learning effectiveness of this course was equivalent, even better, than face-to-face learning because of cross-border collaborative learning, student-centred learning, sufficient learning support, and learning flexibility. This study shows that a high quality of teaching and learning might be assured by

  7. Residual Stress Evaluation of Weld Inlay Process on Reactor Vessel Nozzles

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kihyun; Cho, Hong Seok [KEPCO KPS, Naju (Korea, Republic of)

    2015-10-15

    Weld overlay, weld inlay and stress improvement are mitigation technologies for butt joints. Weld overlay is done on pressurizer nozzles which are the highest potential locations occurring PWSCC due to high temperature in Korea. Reactor vessel nozzles are other big safety concerns for butt joints. Weld overlay and stress improvement should be so difficult to apply to those locations because space is too limited. Weld inlay should be one of the solutions. KEPCO KPS has developed laser welding system and process for reactor nozzles. Welding residual stress analysis is necessary for flaw evaluation. United States nuclear regulatory commission has calculated GTAW(Gas Tungsten Arc Welding) residual stress using ABAQUS. To confirm effectiveness of weld inlay process, welding residual stress analysis was performed. and difference between GTAW and LASER welding process was compared. Evaluation of weld inlay process using ANSYS and ABAQUS is performed. All of the both results are similar. The residual stress generated after weld inlay was on range of 450-500 MPa. Welding residual stresses are differently generated by GTAW and LASER welding. But regardless of welding process type, residual tensile stress is generated on inside surface.

  8. Joint shape segmentation with linear programming

    KAUST Repository

    Huang, Qixing

    2011-01-01

    We present an approach to segmenting shapes in a heterogenous shape database. Our approach segments the shapes jointly, utilizing features from multiple shapes to improve the segmentation of each. The approach is entirely unsupervised and is based on an integer quadratic programming formulation of the joint segmentation problem. The program optimizes over possible segmentations of individual shapes as well as over possible correspondences between segments from multiple shapes. The integer quadratic program is solved via a linear programming relaxation, using a block coordinate descent procedure that makes the optimization feasible for large databases. We evaluate the presented approach on the Princeton segmentation benchmark and show that joint shape segmentation significantly outperforms single-shape segmentation techniques. © 2011 ACM.

  9. About subjective evaluation of adaptive video streaming

    Science.gov (United States)

    Tavakoli, Samira; Brunnström, Kjell; Garcia, Narciso

    2015-03-01

    The usage of HTTP Adaptive Streaming (HAS) technology by content providers is increasing rapidly. Having available the video content in multiple qualities, using HAS allows to adapt the quality of downloaded video to the current network conditions providing smooth video-playback. However, the time-varying video quality by itself introduces a new type of impairment. The quality adaptation can be done in different ways. In order to find the best adaptation strategy maximizing users perceptual quality it is necessary to investigate about the subjective perception of adaptation-related impairments. However, the novelties of these impairments and their comparably long time duration make most of the standardized assessment methodologies fall less suited for studying HAS degradation. Furthermore, in traditional testing methodologies, the quality of the video in audiovisual services is often evaluated separated and not in the presence of audio. Nevertheless, the requirement of jointly evaluating the audio and the video within a subjective test is a relatively under-explored research field. In this work, we address the research question of determining the appropriate assessment methodology to evaluate the sequences with time-varying quality due to the adaptation. This was done by studying the influence of different adaptation related parameters through two different subjective experiments using a methodology developed to evaluate long test sequences. In order to study the impact of audio presence on quality assessment by the test subjects, one of the experiments was done in the presence of audio stimuli. The experimental results were subsequently compared with another experiment using the standardized single stimulus Absolute Category Rating (ACR) methodology.

  10. Durability of saw-cut joints in plain cement concrete pavements : [technical summary].

    Science.gov (United States)

    2011-01-01

    The main objective of this study was to evaluate factors influencing the durability of the joints in portland cement concrete pavement in the state of Indiana. : The scope of the research included the evaluation of the absorption of water in concrete...

  11. Evaluation Strategy

    DEFF Research Database (Denmark)

    Coto Chotto, Mayela; Wentzer, Helle; Dirckinck-Holmfeld, Lone

    2009-01-01

    The paper presents an evaluation strategy based on deliberate ideals and principles of dialogue design. The evaluation strategy is based on experiential phenomenology taking the point of departure for design and evaluation processes in the experienced practitioners themselves. The article present...... the evaluation strategy and methodology of a research project Making Online Path to Enter new Markets, MOPEM. It is an EU-research project with partners from different Educational Institutions of Technology and Business in five European Countries.......The paper presents an evaluation strategy based on deliberate ideals and principles of dialogue design. The evaluation strategy is based on experiential phenomenology taking the point of departure for design and evaluation processes in the experienced practitioners themselves. The article presents...

  12. Collaborative Evaluation within a Framework of Stakeholder-Oriented Evaluation Approaches

    Science.gov (United States)

    O'Sullivan, Rita G.

    2012-01-01

    Collaborative Evaluation systematically invites and engages stakeholders in program evaluation planning and implementation. Unlike "distanced" evaluation approaches, which reject stakeholder participation as evaluation team members, Collaborative Evaluation assumes that active, on-going engagement between evaluators and program staff,…

  13. A stress MRI of the shoulder for evaluation of ligamentous stabilizers in acute and chronic acromioclavicular joint instabilities.

    Science.gov (United States)

    Izadpanah, Kaywan; Winterer, Jan; Vicari, Marco; Jaeger, Martin; Maier, Dirk; Eisebraun, Leonie; Ute Will, Jutta; Kotter, Elmar; Langer, Mathias; Südkamp, Norbert P; Hennig, Jürgen; Weigel, Mathias

    2013-06-01

    To show the feasibility of a stress magnetic resonance imaging (MRI) as a new method for simultaneous evaluation of the morphology and the functional integrity of the acromioclavicular joint (ACJ) ligamentous stabilizers. MRI of four volunteers, 10 patients with acute, and six with chronic ACJ injuries was performed using a 0.25 T open MRI scanner. A 2D-proton-density and a 3D-gradient-echo sequence at rest and under 6.5 kg shoulder traction were performed. Comparative measurements of the coracoclavicular and the acromioclavicular distance were performed. Additionally, the conoid and trapezoid ligament lengths were measured with multiplanar reconstructions. MRI at rest correctly identified tears of the coracoclavicular and the acromioclavicular ligaments in eight patients suffering acute ACJ injuries. Stress application helped to distinguish between partial and complete coracoclavicular ligament tears in two cases. Insufficiency of the ACJ ligaments was present in all acute and chronic ACJ injuries. Stress application in chronic ACJ ligaments revealed isolated insufficiency of the conoid ligament in three cases and of the trapezoid ligament in one case. Combined insufficiency was present in two cases. Stress MRI facilitates simultaneous acquisition of morphologic and functional information of the ACJ stabilizers. In acute ACJ injuries it helps to distinguish between partial and complete ligament tears. In chronic ACJ injuries it provides functional information of the ligament regrinds. Copyright © 2012 Wiley Periodicals, Inc.

  14. Pathological Knee Joint Motion Analysis By High Speed Cinephotography

    Science.gov (United States)

    Baumann, Jurg U.

    1985-02-01

    The use of cinephotography for evaluation of disturbed knee joint function was compared in three groups of patients. While a sampling rate of 50 images per second was adequate for patients with neuromuscular disorders, a higher frequency of around 300 i.p.s. is necessary in osteoarthritis and ligamentous knee joint injuries, but the task of digitizing is prohibitive unless automated.

  15. Actively Secure Two-Party Evaluation of Any Quantum Operation

    DEFF Research Database (Denmark)

    Dupuis, Frédéric; Nielsen, Jesper Buus; Salvail, Louis

    2012-01-01

    We provide the first two-party protocol allowing Alice and Bob to evaluate privately even against active adversaries any completely positive, trace-preserving map , given as a quantum circuit, upon their joint quantum input state . Our protocol leaks no more to any active adversary than an ideal ...... functionality for provided Alice and Bob have the cryptographic resources for active secure two-party classical computation. Our protocol is constructed from the protocol for the same task secure against specious adversaries presented in [4]....

  16. Axial loaded stress views and kinematic MR imaging evaluation of patellar alignment and tracking

    International Nuclear Information System (INIS)

    Shellock, F.G.; Mink, J.H.; Deutsch, A.; Meeks, T.; Fox, J.; Molnar, T.

    1990-01-01

    This paper evaluates patellar alignment and tracking in patients with suspected abnormalities by obtaining axial loaded stress views to assess dynamic stabilizers and kinematic MR images to assess static stabilizers of the patellofemoral joint. Ninety-eight symptomatic joints were studied; 21 joints had prior realignment surgery. Axial loaded stress views were achieved with a device that simulated weight bearing. Images were obtained with knees flexed at 20 degrees ± 5 degrees while the patient resisted with an isometric contraction. Kinematic MR imaging was performed according to previously described methods. Kinematic MR imaging showed normal findings in six joints, lateral subluxation in 22, medial subluxation in 58, lateral tilt in two, and lateral to medial subluxation in 10. Axial stress views showed normal findings in 30, lateral subluxation in 18, and medial subluxation in 50. Both tests agreed on abnormalities for 63% of the joints, while kinematic MR imaging showed abnormalities for an additional 32%

  17. Polish Adaptation of Wrist Evaluation Questionnaires.

    Science.gov (United States)

    Czarnecki, Piotr; Wawrzyniak-Bielęda, Anna; Romanowski, Leszek

    2015-01-01

    Questionnaires evaluating hand and wrist function are a very useful tool allowing for objective and systematic recording of symptoms reported by the patients. Most questionnaires generally accepted in clinical practice are available in English and need to be appropriately adapted in translation and undergo subsequent validation before they can be used in another culture and language. The process of translation of the questionnaires was based on the generally accepted guidelines of the International Quality of Life Assessment Project (IQOLA). First, the questionnaires were translated from English into Polish by two independent translators. Then, a joint version of the translation was prepared collectively and translated back into English. Each stage was followed by a written report. The translated questionnaires were then evaluated by a group of patients. We selected 31 patients with wrist problems and asked them to complete the PRWE, Mayo, Michigan and DASH questionnaires twice at intervals of 3-10 days. The results were submitted for statistical analysis. We found a statistically significant (pquestionnaires. A comparison of the PRWE and Mayo questionnaires with the DASH questionnaire also showed a statistically significant correlation (pquestionnaires was successful and that the questionnaires may be used in clinical practice.

  18. Energy-efficient buildings program evaluations. Volume 2: Evaluation summaries

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A.D.; Mayi, D.; Edgemon, S.D.

    1997-04-01

    This document presents summaries of code and utility building program evaluations reviewed as the basis for the information presented in Energy-Efficient Buildings Program Evaluations, Volume 1: Findings and Recommendations, DOE/EE/OBT-11569, Vol. 1. The main purpose of this volume is to summarize information from prior evaluations of similar programs that may be useful background for designing and conducting an evaluation of the BSGP. Another purpose is to summarize an extensive set of relevant evaluations and provide a resource for program designers, mangers, and evaluators.

  19. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    Science.gov (United States)

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Aging evaluation of active components by using performance evaluation

    International Nuclear Information System (INIS)

    Jung, S. K.; Jin, T. E.; Kim, J. S.; Jung, I. S.; Kim, T. R.

    2003-01-01

    Risk analysis and performance evaluation methodology were applied to the aging evaluation of active components in the periodic safety review of Wolsung unit 1. We conclude that evaluation of performance is more effective to discriminate the aging degradation of active component than the evaluation of aging mechanism. It is essential to analyze the common cause failures of low performance components to evaluate the properness of present maintenance system. Past 10 years failure history is used for establishing the performance criteria. Past 2 years failure history is used for the evaluating the recent performance condition. We analyze the failure mode of the components to improve the maintenance system. Performance evaluation methodology is useful for the quantitative evaluation of aging degradation of active components. Analysis on the repeated failures can be useful for the feedback to maintenance plan and interval

  1. Development and Evaluation of Wide Clearance Braze Joints in Gamma Prime Alloys.

    Science.gov (United States)

    1982-03-01

    process , it also cleans crack surfaces, and this opens a way to repair the very costly parts. Since the alloys contain aluminum and titanium , post- weld ...assembly was comr Let ,d by weld tacking the ends of the T-bar with a TIG torch. Sufficient T-bars of each parent alloy were prepared so that each surface...fluorocarbon cleaning process (FCP). For the right filler metal combination (Ren6 80 with D 15 alloy ) joint tensile strengths rivalled the base metal

  2. Stress indices for girth welded joints, including radial weld shrinkage, mismatch and tapered-wall transitions

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.

    1978-09-01

    A review is presented of B, C and K stress indices used in the ASME Nuclear Power Plant Code for girth butt welds and girth fillet welds. Theoretical stresses are presented to aid in evaluating C-indices. Fatigue test data are presented to aid in evaluating K-indices and CK-products. A limit load theory is presented to aid in evaluating B-indices. As a result of this review, recommendations are made for changes in the ASME Code. A major part of this consists of presenting definitions for girth welded joints and transitions and appropriate stress indices for those joints

  3. Using a finite element pediatric hip model in clinical 2 evaluation - a feasibility study

    DEFF Research Database (Denmark)

    Skytte, T. L.; Mikkelsen, Lars Pilgaard; Sonne-Holm, Stig

    2017-01-01

    The paper describe a method to construct a finite element model of the hip joint of a child based on clinical recorded CT data. A model which can be used for diagnostic aid and pre-operative surgical evaluation. First part of this development is a feasibility study of this method. A scan...... to previous published experimental studies and computational models investigating the adult hip joint. Good correlation between the current model and previous models were found. The current case specific modeling technique may be a useful complement to the previously developed hip models....

  4. Comparison between ultrasound and plain X-ray in evaluating the cause of shoulder pain.

    Science.gov (United States)

    Salek, K M; Mannan, M; Chowdhury, A Z; Haque, M A; Kaiser, M S; Nabi, S; Ferdousee, R A; Paul, B K; Ahmed, S M; Khan, M; Begum, M

    2011-01-01

    Painful shoulder is a common painful condition among patients. Apart from acute traumatic lesions such as fractures, dislocations, contusions, sprains and ruptured tendons, 85 to 90% of painful shoulders are due to adhesive capsulitis, acute or chronic calcific tendinitis, bursitis, bicipital tendinitis and lesions of the musculotendinous cuff. Arthritis is the cause of less than 5% of painful shoulders. For evaluating conditions of shoulder joint, X-ray has been regarded as only method of choice for long time. Magnetic resonance imaging (MRI) is an alternative procedure but the cost limits its utilization especially in Bangladesh. Ultrasonography is an effective imaging modality in the evaluation of both rotator and non-rotator cuff disorders. Because of low cost and availability, it can be an alternative procedure for the diagnosis of painful shoulder. The present study was conducted to assess ultrasonography as a useful modality in evaluating cases of shoulder pain and to compare the findings with X-ray findings. Thirty two patients with shoulder pain were evaluated by X-ray and Ultrasonography (USG). Clinical diagnosis was done for correlation. To identify the cause of shoulder pain, 100% patients were found normal in plain X-ray. On Ultrasonography (USG) 12.5% patients had displaced long head of biceps, 21.9% had biceps tendinitis, and 3.1% had bursitis. In the assessment of shoulder pathology, USG had a sensitivity of 73.3%, specificity of 88.2%, Positive predictive value (PPV) of 84.6%, Negative predictive value (NPV) of 78.9% and an accuracy of 81.3%. USG is a useful modality for evaluation the shoulder joint in case of painful shoulder even plain X-ray is non conclusive.

  5. Techniques for assessing knee joint pain in arthritis

    Directory of Open Access Journals (Sweden)

    Fu Yu

    2007-03-01

    Full Text Available Abstract The assessment of pain is of critical importance for mechanistic studies as well as for the validation of drug targets. This review will focus on knee joint pain associated with arthritis. Different animal models have been developed for the study of knee joint arthritis. Behavioral tests in animal models of knee joint arthritis typically measure knee joint pain rather indirectly. In recent years, however, progress has been made in the development of tests that actually evaluate the sensitivity of the knee joint in arthritis models. They include measurements of the knee extension angle struggle threshold, hind limb withdrawal reflex threshold of knee compression force, and vocalizations in response to stimulation of the knee. A discussion of pain assessment in humans with arthritis pain conditions concludes this review.

  6. Postoperative radiologic imaging of joint arthroplasty; Postoperative radiologische Beurteilung von Gelenkendoprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Aldinger, P.R. [Abt. Orthopaedie I, Orthopaedische Universitaetsklinik Heidelberg (Germany); Ludwig, K. [Sektion Diagnostische Radiologie, Orthopaedische Universitaetsklinik Heidelberg (Germany)

    2006-06-15

    With increased life expectancy in industrialised countries, improvement of implant design and operative technique, arthroplasty has become a routine procedure. The hip and knee joints are treated by arthroplasty most frequently. Nowadays joint replacement can be performed in many other joints. Radiologic imaging is an important tool for evaluation of the operative results and for detection of early and late complications. In the following article we describe the relevance of different imaging modalities as well as their systematic application in patients with joint arthroplasty. (orig.)

  7. Testing of the Structure and Mechanical Properties of Technical Titanium Joints

    Directory of Open Access Journals (Sweden)

    Bogumił Wronka

    2013-01-01

    Full Text Available The aim of the research was the titanium pipeline welding technology. The transformations of this material due to the influence of thermal welding were analysed. The basic purpose was to evaluate the properties of titanium joint areas. Pipe joints of various thicknesses were welded by means of TIG argon arc welding while applying the optimum and reduced gas flow intensities. The structure and mechanical properties of these joints were tested. Different test results were obtained for joints welded in these two conditions. Recommendations concerning the welding technology and the heat treatment of joints after welding were presented.

  8. Secondary Evaluations.

    Science.gov (United States)

    Cook, Thomas D.

    Secondary evaluations, in which an investigator takes a body of evaluation data collected by a primary evaluation researcher and examines the data to see if the original conclusions about the program correspond with his own, are discussed. The different kinds of secondary evaluations and the advantages and disadvantages of each are pointed out,…

  9. 3D Analysis of the Proximal Interphalangeal Joint Kinematics during Flexion

    Directory of Open Access Journals (Sweden)

    Florian Hess

    2013-01-01

    Full Text Available Background. Dynamic joint motion recording combined with CT-based 3D bone and joint surface data is accepted as a helpful and precise tool to analyse joint. The purpose of this study is to demonstrate the feasibility of these techniques for quantitative motion analysis of the interphalangeal joint in 3D. Materials and Method. High resolution motion data was combined with an accurate 3D model of a cadaveric index finger. Three light-emitting diodes (LEDs were used to record dynamic data, and a CT scan of the finger was done for 3D joint surface geometry. The data allowed performing quantitative evaluations such as finite helical axis (FHA analysis, coordinate system optimization, and measurement of the joint distances in 3D. Results. The FHA varies by 4.9±1.7° on average. On average, the rotation in adduction/abduction and internal/external rotation were 0.3±0.91° and 0.1±0.97°, respectively. During flexion, a translational motion between 0.06 mm and 0.73 mm was observed. Conclusions. The proposed technique and methods appear to be feasible for the accurate assessment and evaluation of the PIP joint motion in 3D. The presented method may help to gain additional insights for the design of prosthetic implants, rehabilitation, and new orthotic devices.

  10. BEHAVIOR OF GLUED JOINTS OF EUCALYPTUS sp. SAWN WOOD

    Directory of Open Access Journals (Sweden)

    Octávio Barbosa Plaster

    2008-09-01

    Full Text Available This research evaluated eucalypt wood adhesion capacity. The material evaluated was a commercial sawn wood composed by a blend of species of the genus Eucalyptus. The adhesives used were resorcinol-formaldehyde and polyvinila acetate (PVAc. The wood was segregated in three density with 0% of moisture content: class 1; 2 and 3 that, when combined (class1 x class1; 2x2; 3x3; 1x2; 1x3; 2x3 resulted in six treatments. The performance of the adhesion was evaluated by the shear strength to parallel compression and by wood failure in the glue line. The obtained results allowed to conclude that the adhesion of the combinations of wood/adhesive presented satisfactory performance. The average shear strength of the joints were shown equivalent to the shear strength of the solid wood with similar performance of adhesion in the two adhesives. In general, resorcinol-formaldheyde adhesive presented higher values (74.41% for wood failure in the joints, but similar to all treatments. The adhesion of samples of higher density presented lower performance probably when only the values of wood failure are considered. The values for the strength of glued joints, in general, were similar when analyzed the results achieved with the resorcinol-formaldehyde adhesive- base 140,56 Kgf/cm2. To polyvinila acetate the values of wood failure decrease when the density increase (65.94%, but the resistance in the glue line was positively affected (140.25 Kgf/cm2. In general, the density influenced the adhesion of the joints for the employed adhesives.

  11. Engineering Evaluation/Cost Analysis for Decommissioning of the Engineering Test Reactor Complex

    International Nuclear Information System (INIS)

    A. B. Culp

    2006-01-01

    Preparation of this Engineering Evaluation/Cost Analysis is consistent with the joint U.S. Department of Energy and U.S. Environmental Protection Agency Policy on Decommissioning of Department of Energy Facilities Under the Comprehensive Environmental Response, Compensation, and Liability Act, which establishes the Comprehensive Environmental Response, Compensation, and Liability Act non-time-critical removal action (NTCRA) process as an approach for decommissioning

  12. Engineering Evaluation/Cost Analysis for Decommissioning of the Engineering Test Reactor Complex

    Energy Technology Data Exchange (ETDEWEB)

    A. B. Culp

    2006-10-01

    Preparation of this Engineering Evaluation/Cost Analysis is consistent with the joint U.S. Department of Energy and U.S. Environmental Protection Agency Policy on Decommissioning of Department of Energy Facilities Under the Comprehensive Environmental Response, Compensation, and Liability Act, which establishes the Comprehensive Environmental Response, Compensation, and Liability Act non-time-critical removal action (NTCRA) process as an approach for decommissioning.

  13. Distal radioulnar joint injuries

    Directory of Open Access Journals (Sweden)

    Binu P Thomas

    2012-01-01

    Full Text Available Distal radioulnar joint is a trochoid joint relatively new in evolution. Along with proximal radioulnar joint , forearm bones and interosseous membrane, it allows pronosupination and load transmission across the wrist. Injuries around distal radioulnar joint are not uncommon, and are usually associated with distal radius fractures,fractures of the ulnar styloid and with the eponymous Galeazzi or Essex_Lopresti fractures. The injury can be purely involving the soft tissue especially the triangular fibrocartilage or the radioulnar ligaments.The patients usually present with ulnar sided wrist pain, features of instability, or restriction of rotation. Difficulty in carrying loads in the hand is a major constraint for these patients. Thorough clinical examination to localize point of tenderness and appropriate provocative tests help in diagnosis. Radiology and MRI are extremely useful, while arthroscopy is the gold standard for evaluation. The treatment protocols are continuously evolving and range from conservative, arthroscopic to open surgical methods. Isolated dislocation are uncommon. Basal fractures of the ulnar styloid tend to make the joint unstable and may require operative intervention. Chronic instability requires reconstruction of the stabilizing ligaments to avoid onset of arthritis. Prosthetic replacement in arthritis is gaining acceptance in the management of arthritis.

  14. Evaluation of the joint distribution at disease presentation of patients with rheumatoid arthritis: a large study across continents.

    Science.gov (United States)

    Bergstra, Sytske Anne; Chopra, Arvind; Saluja, Manjit; Vega-Morales, David; Govind, Nimmisha; Huizinga, Tom W J; van der Helm-van Mil, Annette

    2017-01-01

    Genetic and environmental risk factors for rheumatoid arthritis (RA) are population dependent and may affect disease expression. Therefore, we studied tender and swollen joint involvement in patients newly diagnosed with RA in four countries and performed a subanalysis within countries to assess whether the influence of autoantibody positivity affected disease expression. Patients with symptom duration <2 years fulfilling the American College of Rheumatology/European League Against Rheumatism 2010 RA classification criteria were selected from METEOR (Measurement of Efficacy of Treatment in the Era of Outcome in Rheumatology), an international observational database, and the Dutch Leiden Early Arthritis Clinic. Indian (n=947), Mexican (n=141), South African (n=164) and Dutch (n=947) autoantibody-positive and negative patients with RA, matched by symptom duration, were studied for swollen and tender joint distribution. Between countries, the reported distribution of swollen joint distribution differed, with more knee synovitis in Mexico, South Africa and India compared with the Netherlands (37%, 36%, 30% and 13%) and more elbow (29%, 23%, 7%, 7%) and shoulder synovitis (21%, 11%, 0%, 1%) in Mexico and South Africa compared with India and the Netherlands.Since the number of autoantibody-negative patients in Mexico and South Africa was limited, Indian and Dutch autoantibody-positive and negative patients with RA were compared. The number of swollen and tender joints was higher in autoantibody-negative patients, but the overall distribution of involved joints was similar. Joint involvement at diagnosis does not differ between autoantibody-positive and negative patients with RA in India and the Netherlands. However, joint involvement is reported differently across countries. More research is needed whether these differences are cultural and/or pathogenetic.

  15. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    Science.gov (United States)

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  16. Design and preliminary evaluation of an exoskeleton for upper limb resistance training

    Science.gov (United States)

    Wu, Tzong-Ming; Chen, Dar-Zen

    2012-06-01

    Resistance training is a popular form of exercise recommended by national health organizations, such as the American College of Sports Medicine (ACSM) and the American Heart Association (AHA). This form of training is available for most populations. A compact design of upper limb exoskeleton mechanism for homebased resistance training using a spring-loaded upper limb exoskeleton with a three degree-of-freedom shoulder joint and a one degree-of-freedom elbow joint allows a patient or a healthy individual to move the upper limb with multiple joints in different planes. It can continuously increase the resistance by adjusting the spring length to train additional muscle groups and reduce the number of potential injuries to upper limb joints caused by the mass moment of inertia of the training equipment. The aim of this research is to perform a preliminary evaluation of the designed function by adopting an appropriate motion analysis system and experimental design to verify our prototype of the exoskeleton and determine the optimal configuration of the spring-loaded upper limb exoskeleton.

  17. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction.

    Science.gov (United States)

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-02-01

    Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student's T test was used. There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction.

  18. Didatic approach of ultrasonographic examination for evaluation of the carpal joint in horses

    Directory of Open Access Journals (Sweden)

    Maria Cristina Ferrarini Nunes Soares Hage

    2017-11-01

    Full Text Available ABSTRACT: The carpus is a complex articulation, which is often involved in injuries in equine athletes. The objective of this study was to suggest a didactic approach for ultrasonography training for the examination of the carpal joint in horses. Ultrasonograhy examination was performed in a healthy 14-year-old horse. The images were compared with those of a dissected anatomic specimen of the carpal region of a senior horse and with those reported in the literature. Identifiable structures were as follows: (dorsal tendon of the muscle extensor carpi radialis, tendon of the muscle extensor carpi obliquus, tendon of the muscle commom digital extensor, dorsal synovial outpouchings, joint capsule and fat cushion, (lateral tendon of the muscle lateral digital extensor, lateral collateral ligament (deep and superficial components, (medial medial collateral ligament (deep and superficial components and (palmar palmar intercarpal ligament, carpal sheath, carpal tunnel, superficial digital flexor tendon, proximal origin of the deep digital flexor tendon, and palmar carpal ligament. Prior knowledge of the anatomy in combination with the study of anatomical specimens is essential for recognizing musculoskeletal structures during ultrasound examination, contributing to the training and learning processes.

  19. The status of proliferation resistance evaluation methodology development in GEN IV international forum

    International Nuclear Information System (INIS)

    Inoue, Naoko; Kawakubo, Yoko; Seya, Michio; Suzuki, Mitsutoshi; Kuno, Yusuke; Senzaki, Masao

    2010-01-01

    The Generation IV Nuclear Energy Systems International Forum (GIF) Proliferation Resistance and Physical Protection Working Group (PR and PP WG) was established in December 2002 in order to develop the PR and PP evaluation methodology for GEN IV nuclear energy systems. The methodology has been studied and established by international consensus. The PR and PP WG activities include development of the measures and metrics; establishment of the framework of PR and PP evaluation, the demonstration study using Example Sodium Fast Reactor (ESFR), which included the development of three evaluation approaches; the Case Study using ESFR and four kinds of threat scenarios; the joint study with GIF System Steering Committees (SSCs) of the six reactor design concepts; and the harmonization study with the IAEA's International Project on Innovative Nuclear Reactors and Fuel Cycles (INPRO). This paper reviews the status of GIF PR and PP studies and identifies the challenges and directions for applying the methodology to evaluate future nuclear energy systems in Japan. (author)

  20. Nuclear Measurements, Evaluations and Applications (NEMEA-7) Collaborative International Evaluated Library Organisation (CIELO). Workshop Proceedings

    International Nuclear Information System (INIS)

    Chadwick, Mark; Plompen, Arjan; ); Emmeric Dupont; )

    2014-01-01

    The 7. workshop on Nuclear Measurements, Evaluations and Applications (NEMEA) focused on international collaboration in nuclear data by hosting the kick-off meeting of the pilot project of the Collaborative International Evaluated Library Organisation (CIELO). CIELO aims at fostering nuclear data advances by using the joint expertise of the nuclear data community under the auspices of the OECD Nuclear Energy Agency. The workshop aimed at status reviews of planned and completed contributions and related developments for the CIELO pilot isotopes. The workshop further sought to facilitate in-depth discussions on nuclear data issues which are being addressed in the framework of European Commission projects like ERINDA, EUFRAT, ANDES and CHANDA. The 7. workshop on Nuclear Measurements, Evaluations and Applications (NEMEA) provided an opportunity for the Collaborative International Evaluated Library Organisation (CIELO) to meet and advance its objectives to improve our understanding of neutron reactions on key isotopes that are especially important in nuclear applications, especially in the area of criticality safety and reactors. CIELO is focusing initially on six nuclides ( 1 H, 16 O, 56 Fe, 235 U, 238 U and 239 Pu). These nuclides are important in the aforementioned applications, and despite decades of work many open questions remain to be solved. In some cases, the existing evaluations need improvement because the underlying experimental measurements are either lacking or contradictory. In other cases, nuclear theory work is needed to better advance predictions. In yet other cases, information from cross-section measurements is proving difficult to reconcile with information from integral nuclear criticality experiments or neutron shielding experiments. The main challenges to be faced are as follows: For oxygen, new work is needed to better define the total and elastic cross-sections at lower energies and neutron scattering angular distributions. An outstanding

  1. Evaluation of the articular cartilage of the knee joint: value of adding a T2 mapping sequence to a routine MR imaging protocol.

    Science.gov (United States)

    Kijowski, Richard; Blankenbaker, Donna G; Munoz Del Rio, Alejandro; Baer, Geoffrey S; Graf, Ben K

    2013-05-01

    To determine whether the addition of a T2 mapping sequence to a routine magnetic resonance (MR) imaging protocol could improve diagnostic performance in the detection of surgically confirmed cartilage lesions within the knee joint at 3.0 T. This prospective study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The study group consisted of 150 patients (76 male and 74 female patients with an average age of 41.2 and 41.5 years, respectively) who underwent MR imaging and arthroscopy of the knee joint. MR imaging was performed at 3.0 T by using a routine protocol with the addition of a sagittal T2 mapping sequence. Images from all MR examinations were reviewed in consensus by two radiologists before surgery to determine the presence or absence of cartilage lesions on each articular surface, first by using the routine MR protocol alone and then by using the routine MR protocol with T2 maps. Each articular surface was then evaluated at arthroscopy. Generalized estimating equation models were used to compare the sensitivity and specificity of the routine MR imaging protocol with and without T2 maps in the detection of surgically confirmed cartilage lesions. The sensitivity and specificity in the detection of 351 cartilage lesions were 74.6% and 97.8%, respectively, for the routine MR protocol alone and 88.9% and 93.1% for the routine MR protocol with T2 maps. Differences in sensitivity and specificity were statistically significant (P T2 maps to the routine MR imaging protocol significantly improved the sensitivity in the detection of 24 areas of cartilage softening (from 4.2% to 62%, P T2 mapping sequence to a routine MR protocol at 3.0 T improved sensitivity in the detection of cartilage lesions within the knee joint from 74.6% to 88.9%, with only a small reduction in specificity. The greatest improvement in sensitivity with use of the T2 maps was in the identification of early cartilage degeneration. © RSNA

  2. Control of compliant anthropomimetic robot joint

    Directory of Open Access Journals (Sweden)

    Svetozarević Bratislav

    2011-01-01

    Full Text Available In this paper we propose a control strategy for a robot joint which fully mimics the typical human joint structure. The joint drive is based on two actuators (dc motors, agonist and antagonist, acting through compliant tendons and forming a nonlinear multi-input multi-output (MIMO system. At any time, we consider one actuator, the puller, as being responsible for motion control, while the role of the other is to keep its tendon force at some appropriate low level. This human-like and energetically efficient approach requires the control of 'switching', or exchanging roles between actuators. Moreover, an algorithm based on adaptive force reference is used to solve a problem of slacken tendons during the switching and to increase the energy efficiency. This approach was developed and evaluated on increasingly complex robot joint configurations, starting with simple and noncompliant system, and finishing with nonlinear and compliant system.

  3. Methods for reliability evaluation of trust and reputation systems

    Science.gov (United States)

    Janiszewski, Marek B.

    2016-09-01

    Trust and reputation systems are a systematic approach to build security on the basis of observations of node's behaviour. Exchange of node's opinions about other nodes is very useful to indicate nodes which act selfishly or maliciously. The idea behind trust and reputation systems gets significance because of the fact that conventional security measures (based on cryptography) are often not sufficient. Trust and reputation systems can be used in various types of networks such as WSN, MANET, P2P and also in e-commerce applications. Trust and reputation systems give not only benefits but also could be a thread itself. Many attacks aim at trust and reputation systems exist, but such attacks still have not gain enough attention of research teams. Moreover, joint effects of many of known attacks have been determined as a very interesting field of research. Lack of an acknowledged methodology of evaluation of trust and reputation systems is a serious problem. This paper aims at presenting various approaches of evaluation such systems. This work also contains a description of generalization of many trust and reputation systems which can be used to evaluate reliability of such systems in the context of preventing various attacks.

  4. Evaluation of technological measures to cope with climate change

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Hiroshi; Moriguchi, Yulchi [National Inst. for Environmental Studies, Onogawa Tsukuba (Japan)

    1993-12-31

    Because the global warming (climate change) is recognized as a highly probable phenomenon in the next century, the countermeasures to cope with this issue is really Important. International discussion Is progressing towards the conclusion of the treaty to stabilize global warming. Therefore, now is the time to take concrete action to reduce the emission to the greenhouse gases (GHG). To find the way to reduce the emission of the GHG, the procedure as next should be taken. (1) Systematic estimation of GHG emission (GHG analysis), (2) Identification of conventional and Innovative technologies, (3) Assessment of individual sectoral technologies, (4) Comprehensive evaluation of countermeasures as a whole. Both in the U.S.A. and Japan, this kind of research have been made independently. Among these processes, the standard methodologies should be established on the GHG analysis, the assessment of individual technologies and the comprehensive evaluation. From such a background, it is important to discuss the way to evaluate technological measures to cope with climate change between the specialist from the U.S.A. and Japan. And still required to search the possibility to establish a joint project between both countries.

  5. Health economic evaluation in England.

    Science.gov (United States)

    Raftery, James

    2014-01-01

    The 2010 National Health Service Constitution for England specified rights and responsibilities, including health economic evaluation for the National Institute for Health and Care Excellence (NICE) and the Joint Committee on Vaccinations and Immunisations. The National Screening Committee and the Health Protection Agency also provide advice to the Government based on health economic evaluation. Each agency largely follows the methods specified by NICE. To distinguish the methods from neoclassical economics they have been termed "extra-welfarist". Key differences include measurement and valuation of both benefits (QALYs) and costs (healthcare related). Policy on discounting has also changed over time and by agency. The debate over having NICE's methods align more closely with neoclassical economics has been prominent in the ongoing development of "value based pricing". The political unacceptability of some decisions has led to special funding for technologies not recommended by NICE. These include the 2002 Multiple Sclerosis Risk Sharing Scheme and the 2010 Cancer Drugs Fund as well as special arrangements for technologies linked to the end of life and for innovation. Since 2009 Patient Access Schemes have made price reductions possible which sometimes enables drugs to meet NICE's cost-effectiveness thresholds. As a result, the National Health Service in England has denied few technologies on grounds of cost-effectiveness. Copyright © 2014. Published by Elsevier GmbH.

  6. Evaluation of a novel 7-joint ultrasound score in daily rheumatologic practice: a pilot project.

    Science.gov (United States)

    Backhaus, M; Ohrndorf, S; Kellner, H; Strunk, J; Backhaus, T M; Hartung, W; Sattler, H; Albrecht, K; Kaufmann, J; Becker, K; Sörensen, H; Meier, L; Burmester, G R; Schmidt, W A

    2009-09-15

    To introduce a new standardized ultrasound score based on 7 joints of the clinically dominant hand and foot (German US7 score) implemented in daily rheumatologic practice. The ultrasound score included the following joints of the clinically dominant hand and foot: wrist, second and third metacarpophalangeal and proximal interphalangeal, and second and fifth metatarsophalangeal joints. Synovitis and synovial/tenosynovial vascularity were scored semiquantitatively (grade 0-3) by gray-scale (GS) and power Doppler (PD) ultrasound. Tenosynovitis and erosions were scored for presence. The scoring range was 0-27 for GS synovitis, 0-39 for PD synovitis, 0-7 for GS tenosynovitis, 0-21 for PD tenosynovitis, and 0-14 for erosions. Patients with arthritis were examined at baseline and after the start or change of disease-modifying antirheumatic drug (DMARD) and/or tumor necrosis factor alpha (TNFalpha) inhibitor therapy 3 and 6 months later. C-reactive protein level, erythrocyte sedimentation rate, rheumatoid factor, anti-cyclic citrullinated peptide, Disease Activity Score in 28 joints (DAS28), and radiographs of the hands and feet were performed. One hundred twenty patients (76% women) with rheumatoid arthritis (91%) and psoriatic arthritis (9%) were enrolled. In 52 cases (43%), erosions were seen in radiography at baseline. Patients received DMARDs (41%), DMARDs plus TNFalpha inhibitors (41%), or TNFalpha inhibitor monotherapy (18%). At baseline, the mean DAS28 was 5.0 and the synovitis scores were 8.1 in GS ultrasound and 3.3 in PD ultrasound. After 6 months of therapy, the DAS28 significantly decreased to 3.6 (Delta = 1.4), and the GS and PD ultrasound scores significantly decreased to 5.5 (-32%) and 2.0 (-39%), respectively. The German US7 score is a viable tool for examining patients with arthritis in daily rheumatologic practice because it significantly reflects therapeutic response.

  7. Erika: evaluation of residual sanitary risks linked to the beaches-going after cleaning-up; Erika: evaluation des risques sanitaires residuels lies a la frequentation des plages apres depollution

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The aim of this study is to evaluate the sanitary risks for the populations frequenting the coast beaches affected by the fuel oils of the tanker Erika, after their cleaning up. This quantitative evaluation of sanitary risks is led according to a protocol developed jointly between the two institutes ( the national institute of industrial environment and risks, I.N.E.R.I.S., and the national institute of sanitary watch I.n.V.S.). It does not give the risks in function the residual pollution level of concerned beaches but supplies to the authorities elements of scientific information in order to allow them to choose criteria appropriate for the management of eventual residual risks. (N.C.)

  8. Clinical Incidence of Sacroiliac Joint Arthritis and Pain after Sacropelvic Fixation for Spinal Deformity

    Science.gov (United States)

    Sainoh, Takeshi; Takaso, Masashi; Inoue, Gen; Orita, Sumihisa; Eguchi, Yawara; Nakamura, Junichi; Aoki, Yasuchika; Ishikawa, Tetsuhiro; Miyagi, Masayuki; Arai, Gen; Kamoda, Hiroto; Suzuki, Miyako; Kubota, Gou; Sakuma, Yoshihiro; Oikawa, Yasuhiro; Yamazaki, Masashi; Toyone, Tomoaki; Takahashi, Kazuhisa

    2012-01-01

    Purpose Sacroiliac fixation using iliac screws for highly unstable lumbar spine has been reported with an improved fusion rate and clinical results. On the other hand, there is a potential for clinical problems related to iliac fixation, including late sacroiliac joint arthritis and pain. Materials and Methods Twenty patients were evaluated. Degenerative scoliosis was diagnosed in 7 patients, failed back syndrome in 6 patients, destructive spondyloarthropathy in 4 patients, and Charcot spine in 3 patients. All patients underwent posterolateral fusion surgery incorporating lumbar, S1 and iliac screws. We evaluated the pain scores, bone union, and degeneration of sacroiliac joints by X-ray imaging and computed tomography before and 3 years after surgery. For evaluation of low back and buttock pain from sacroiliac joints 3 years after surgery, lidocaine was administered in order to examine pain relief thereafter. Results Pain scores significantly improved after surgery. All patients showed bone union at final follow-up. Degeneration of sacroiliac joints was not seen in the 20 patients 3 years after surgery. Patients showed slight low back and buttock pain 3 years after surgery. However, not all patients showed relief of the low back and buttock pain after injection of lidocaine into the sacroiliac joint, indicating that their pain did not originate from sacroiliac joints. Conclusion The fusion rate and clinical results were excellent. Also, degeneration and pain from sacroiliac joints were not seen within 3 years after surgery. We recommend sacroiliac fixation using iliac screws for highly unstable lumbar spine. PMID:22318832

  9. US findings of metacarpophalangeal joints in children with idiopathic juvenile arthritis

    International Nuclear Information System (INIS)

    Karmazyn, Boaz; Bowyer, Suzanne L.; Murphy Schmidt, Kara; Ballinger, Susan H.; Beam, Thuy T.; Buckwalter, Kenneth; Ying, Jun

    2007-01-01

    Juvenile idiopathic arthritis (JIA) is the most common cause of chronic arthritis in children, with frequent involvement of the metacarpophalangeal joints (MCPJ). To compare US findings with those of radiography and clinical examination. All MCPJs in 20 children with JIA (17 females, median age 9.7 years, range 3.6 to 16.8 years) were evaluated clinically and imaged with gray-scale and color Doppler US, and 90 MCPJs were also imaged radiographically. Each MCPJ was graded on physical examination from 0 (normal) to 4 (severe) by the patient's rheumatologist. US demonstrated abnormalities in 64 of 200 MCPJs (32.0%), including pannus vascularity and/or tenosynovitis in 55 joints (27.5%) (pannus vascularity in 43, tenosynovitis in 40) and bone destruction in 25 joints (12.5%). Overall, US abnormalities and physical examination scores were significantly associated (P < 0.001). However, interobserver agreement between US and clinical evaluation was poor (kappa 0.1) and between US and radiography was only fair (kappa 0.4). US of the MCPJ in children with JIA can demonstrate cartilage thinning, bone erosions, and pannus vascularity. Abnormal US findings are significantly correlated with severity of disease as evaluated clinically. (orig.)

  10. US findings of metacarpophalangeal joints in children with idiopathic juvenile arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Karmazyn, Boaz [Riley Hospital for Children, Radiology, Indianapolis, IN (United States); Bowyer, Suzanne L.; Murphy Schmidt, Kara; Ballinger, Susan H.; Beam, Thuy T. [Indiana University, Pediatric Rheumatology, Indianapolis, IN (United States); Buckwalter, Kenneth [University Hospital, Radiology, Indianapolis, IN (United States); Ying, Jun [University of Cincinnati, Biostatistics, Institute for the Study of Health, Cincinnati, OH (United States)

    2007-05-15

    Juvenile idiopathic arthritis (JIA) is the most common cause of chronic arthritis in children, with frequent involvement of the metacarpophalangeal joints (MCPJ). To compare US findings with those of radiography and clinical examination. All MCPJs in 20 children with JIA (17 females, median age 9.7 years, range 3.6 to 16.8 years) were evaluated clinically and imaged with gray-scale and color Doppler US, and 90 MCPJs were also imaged radiographically. Each MCPJ was graded on physical examination from 0 (normal) to 4 (severe) by the patient's rheumatologist. US demonstrated abnormalities in 64 of 200 MCPJs (32.0%), including pannus vascularity and/or tenosynovitis in 55 joints (27.5%) (pannus vascularity in 43, tenosynovitis in 40) and bone destruction in 25 joints (12.5%). Overall, US abnormalities and physical examination scores were significantly associated (P < 0.001). However, interobserver agreement between US and clinical evaluation was poor (kappa 0.1) and between US and radiography was only fair (kappa 0.4). US of the MCPJ in children with JIA can demonstrate cartilage thinning, bone erosions, and pannus vascularity. Abnormal US findings are significantly correlated with severity of disease as evaluated clinically. (orig.)

  11. Interventions for treating osteoarthritis of the big toe joint.

    Science.gov (United States)

    Zammit, Gerard V; Menz, Hylton B; Munteanu, Shannon E; Landorf, Karl B; Gilheany, Mark F

    2010-09-08

    Osteoarthritis affecting of the big toe joint of the foot (hallux limitus or rigidus) is a common and painful condition. Although several treatments have been proposed, few have been adequately evaluated. To identify controlled trials evaluating interventions for osteoarthritis of the big toe joint and to determine the optimum intervention(s). Literature searches were conducted across the following electronic databases: CENTRAL; MEDLINE; EMBASE; CINAHL; and PEDro (to 14th January 2010). No language restrictions were applied. Randomised controlled trials, quasi-randomised trials, or controlled clinical trials that assessed treatment outcomes for osteoarthritis of the big toe joint. Participants of any age or gender with osteoarthritis of the big toe joint (defined either radiographically or clinically) were included. Two authors examined the list of titles and abstracts identified by the literature searches. One content area expert and one methodologist independently applied the pre-determined inclusion and exclusion criteria to the full text of identified trials. To minimise error and reduce potential bias, data were extracted independently by two content experts. Only one trial satisfactorily fulfilled the inclusion criteria and was included in this review. This trial evaluated the effectiveness of two physical therapy programs in 20 individuals with osteoarthritis of the big toe joint. Assessment outcomes included pain levels, big toe joint range of motion and plantar flexion strength of the hallux. Mean differences at four weeks follow up were 3.80 points (95% CI 2.74 to 4.86) for self reported pain, 28.30 degrees (95% CI 21.37 to 35.23) for big toe joint range of motion, and 2.80 kg (95% CI 2.13 to 3.47) for muscle strength. Although differences in outcomes between treatment and control groups were reported, the risk of bias was high. The trial failed to employ appropriate randomisation or adequate allocation concealment, used a relatively small sample and

  12. Pathology of articular cartilage and synovial membrane from elbow joints with and without degenerative joint disease in domestic cats.

    Science.gov (United States)

    Freire, M; Meuten, D; Lascelles, D

    2014-09-01

    The elbow joint is one of the feline appendicular joints most commonly and severely affected by degenerative joint disease. The macroscopic and histopathological lesions of the elbow joints of 30 adult cats were evaluated immediately after euthanasia. Macroscopic evidence of degenerative joint disease was found in 22 of 30 cats (39 elbow joints) (73.33% cats; 65% elbow joints), and macroscopic cartilage erosion ranged from mild fibrillation to complete ulceration of the hyaline cartilage with exposure of the subchondral bone. Distribution of the lesions in the cartilage indicated the presence of medial compartment joint disease (most severe lesions located in the medial coronoid process of the ulna and medial humeral epicondyle). Synovitis scores were mild overall and correlated only weakly with macroscopic cartilage damage. Intra-articular osteochondral fragments either free or attached to the synovium were found in 10 joints. Macroscopic or histologic evidence of a fragmented coronoid process was not found even in those cases with intra-articular osteochondral fragments. Lesions observed in these animals are most consistent with synovial osteochondromatosis secondary to degenerative joint disease. The pathogenesis for the medial compartmentalization of these lesions has not been established, but a fragmented medial coronoid process or osteochondritis dissecans does not appear to play a role. © The Author(s) 2014.

  13. Evaluation of repository safety

    Energy Technology Data Exchange (ETDEWEB)

    Sagar, B.; Patrick, W.; Dasgupta, B.; Mohanty, S. [Center for Nuclear Waste Regulatory Analyses, San Antonio (United States)

    2002-07-01

    . Mathematical models play an even larger role in evaluating repository safety in the much longer postclosure period. During this period, repository performance is evaluated considering gradual degradation of engineered barriers, together with possible slow changes in the natural system (e.g., climate) and under conditions of potential discrete and sudden disruptive events (e.g., volcanic eruption, seismic ground motion, and direct fault movement). The general aim of postclosure performance assessment models is to simulate the future behavior of the repository in a manner that is sufficiently simplified to be tractable, yet sufficiently realistic to give reasonable (or bounded) estimates of risk to future generations. The simplifications are based on information gained by using process level models, natural analog studies, and laboratory and fieldwork. Because of large uncertainties inherent in characterizing a large and complex system for such long periods, probabilistic simulations are generally preferred. In this paper, we briefly describe the preclosure and postclosure safety evaluation models developed jointly by the Center for Nuclear Waste Regulatory Analyses and the U.S. Nuclear Regulatory Commission. We give examples illustrating how we intend to use these models within the regulatory framework to evaluate the required.

  14. Evaluation of repository safety

    International Nuclear Information System (INIS)

    Sagar, B.; Patrick, W.; Dasgupta, B.; Mohanty, S.

    2002-01-01

    . Mathematical models play an even larger role in evaluating repository safety in the much longer postclosure period. During this period, repository performance is evaluated considering gradual degradation of engineered barriers, together with possible slow changes in the natural system (e.g., climate) and under conditions of potential discrete and sudden disruptive events (e.g., volcanic eruption, seismic ground motion, and direct fault movement). The general aim of postclosure performance assessment models is to simulate the future behavior of the repository in a manner that is sufficiently simplified to be tractable, yet sufficiently realistic to give reasonable (or bounded) estimates of risk to future generations. The simplifications are based on information gained by using process level models, natural analog studies, and laboratory and fieldwork. Because of large uncertainties inherent in characterizing a large and complex system for such long periods, probabilistic simulations are generally preferred. In this paper, we briefly describe the preclosure and postclosure safety evaluation models developed jointly by the Center for Nuclear Waste Regulatory Analyses and the U.S. Nuclear Regulatory Commission. We give examples illustrating how we intend to use these models within the regulatory framework to evaluate the required

  15. Evaluation of Power Generation Efficiency of Cascade Hydropower Plants: A Case Study

    Directory of Open Access Journals (Sweden)

    Jiahua Wei

    2013-02-01

    Full Text Available Effective utilization of scarce water resources has presented a significant challenge to respond to the needs created by rapid economic growth in China. In this study, the efficiency of the joint operation of the Three Gorges and Gezhouba cascade hydropower plants in terms of power generation was evaluated on the basis of a precise simulation-optimization technique. The joint operation conditions of the Three Gorges and Gezhouba hydropower plants between 2004 and 2010 were utilized in this research in order to investigate the major factors that could affect power output of the cascade complex. The results showed that the current power output of the Three Gorges and Gezhouba cascade complex had already reached around 90% of the maximum theoretical value. Compared to other influencing factors evaluated in this study, the accuracy of hydrological forecasts and flood control levels can have significant impact on the power generating efficiency, whereas the navigation has a minor influence. This research provides a solid quantitative-based methodology to assess the operation efficiency of cascade hydropower plants, and more importantly, proposes potential methods that could improve the operation efficiency of cascade hydropower plants.

  16. Evaluate to Improve: Useful Approaches to Student Evaluation

    Science.gov (United States)

    Golding, Clinton; Adam, Lee

    2016-01-01

    Many teachers in higher education use feedback from students to evaluate their teaching, but only some use these evaluations to improve their teaching. One important factor that makes the difference is the teacher's approach to their evaluations. In this article, we identify some useful approaches for improving teaching. We conducted focus groups…

  17. Correlation between generalized joint hypermobility and hallux valgus

    Directory of Open Access Journals (Sweden)

    A. A. Kardanov

    2015-01-01

    Full Text Available Purpose: to evaluate correlation between generalized joint hypermobility, forefoot deformities and elasticity of the first ray of the foot. Material and methods. We examined 138 patients with complaints related with deformities at the forefoot level. During this study the medical history was obtained, the elasticity type of the feet was defined and the degree of motion of the medial metatarsal-cuneiform joint was evaluated. Forefoot elasticity was identified by bringing together the heads I and V metatarsal bones with fingers. If convergence occurred with little resistance, those feet were called hyperelastic. The convergence of the heads I and V metatarsal bones of the foot with an average type of elasticity occurred with resistance. It was impossible to converge the heads of I and V metatarsal bones. Due to the results of weight-bearing and non-weight bearing X-ray, analysis of the main radiographic angles of the foot was performed: between I and V metatarsal bones, between the first and second metatarsal bones and between the first metatarsal bone and proximal phalanx of the great toe. Calculation formula of the forefoot flatness index, showing the average ratios of basic radiographic angles of the foot on the x-ray images (weight-bearing and non-weight bearing was created. An assessment of total joint hypermobility using Beighton scale and evaluation of first ray deformity using DuPont scale were performed. Statistical analysis of obtained data was performed, as a result of which significantly strong correlation between total joint hypermobility, forefoot elasticity and valgus deviation of the great toe were revealed. Results. 11% of the feet were hyperelastic. Calculation of the index of forefoot flatness showed that forefoot flatness wasn’t significant for a rigid foot - 5.6 %, for the feet with an average degree of mobility it was 6.0% and it was expressed for hypemobile feet - 12.3 %. Strong correlation relation between the forefeet

  18. Evaluating evaluation as a communication process. What role for formative evaluation in ICT-based knowledge acquisition?

    Directory of Open Access Journals (Sweden)

    USEILLE Philippe

    2005-10-01

    Full Text Available This article examines how formative evaluation as a communication process contributes to knowledge acquisition in using ICT (Information and Communication Technologies. Previous studies, especially in the field of education and training, have shown that formative evaluation plays a crucial part in the learning process because it contributes to learning to learn. Through formative evaluation, the learner becomes aware of errors and can adjust learning strategies to the situation. In addition, formative evaluation provides the teaching side with significant and useful information. Consequently, ICT researches have developed a wide range of solutions for this specific purpose. It is however difficult to check the efficiency of these tools by considering the effects of ICT in the knowledge acquisition process. I suggest that formative evaluation includes also a communication system that has an effect on the learning process. This study tackles the issue by proposing an alternative approach to formative evaluation that considers it as both a learning and a communication process. The study is based on SADT (Structure Analysis and Design Technique that provides a suitable description for the whole complex communication process. It allows a rigorous understanding and identification of the variables of evaluation as a communication process in order to take care of an ICT frame. Finally, this article outlines a multidisciplinary method to evaluate formative evaluation by focusing on the validity facets of the communication process. Keywords: formative evaluation, communication process, validity criteria, ICT training context.

  19. Cancer risk among patients with finger and hand joint and temporo-mandibular joint prostheses in Denmark.

    Science.gov (United States)

    Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H

    1999-05-31

    The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.

  20. Decree 435/994 Environmental Impacts : establish a standard joint complex named Evaluation Regulations

    International Nuclear Information System (INIS)

    1994-01-01

    The Regulation of Evaluation of environmental Impact in the chapter I art.2 item 14 it establishes that It will require the previous Environmental Authorization the activities that refer to the construction of production factories and transformation of Nuclear Energy r, without damage of that settled down for the articulate 215 of the law 16.226 of October 29 1991 [es