WorldWideScience

Sample records for evaluation facility classification

  1. Radioactive facilities classification criteria

    International Nuclear Information System (INIS)

    Briso C, H.A.; Riesle W, J.

    1992-01-01

    Appropriate classification of radioactive facilities into groups of comparable risk constitutes one of the problems faced by most Regulatory Bodies. Regarding the radiological risk, the main facts to be considered are the radioactive inventory and the processes to which these radionuclides are subjected. Normally, operations are ruled by strict safety procedures. Thus, the total activity of the radionuclides existing in a given facility is the varying feature that defines its risk. In order to rely on a quantitative criterion and, considering that the Annual Limits of Intake are widely accepted references, an index based on these limits, to support decisions related to radioactive facilities, is proposed. (author)

  2. 33 CFR 154.1216 - Facility classification.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Facility classification. 154.1216... Vegetable Oils Facilities § 154.1216 Facility classification. (a) The Coast Guard classifies facilities that... classification of a facility that handles, stores, or transports animal fats or vegetable oils. The COTP may...

  3. Hazard Classification for Fuel Supply Shutdown Facility

    International Nuclear Information System (INIS)

    BENECKE, M.W.

    2000-01-01

    Final hazard classification for the 300 Area N Reactor fuel storage facility resulted in the assignment of Nuclear Facility Hazard Category 3 for the uranium metal fuel and feed material storage buildings (303-A, 303-B, 303-G, 3712, and 3716). Radiological for the residual uranium and thorium oxide storage building and an empty former fuel storage building that may be used for limited radioactive material storage in the future (303-K/3707-G, and 303-E), and Industrial for the remainder of the Fuel Supply Shutdown buildings (303-F/311 Tank Farm, 303-M, 313-S, 333, 334 and Tank Farm, 334-A, and MO-052)

  4. Materiel Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — CRREL's Materiel Evaluation Facility (MEF) is a large cold-room facility that can be set up at temperatures ranging from −20°F to 120°F with a temperature change...

  5. Airborne Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — AFRL's Airborne Evaluation Facility (AEF) utilizes Air Force Aero Club resources to conduct test and evaluation of a variety of equipment and concepts. Twin engine...

  6. Facilities evaluation report

    International Nuclear Information System (INIS)

    Sloan, P.A.; Edinborough, C.R.

    1992-04-01

    The Buried Waste Integrated Demonstration (BWID) is a program of the Department of Energy (DOE) Office of Technology Development whose mission is to evaluate different new and existing technologies and determine how well they address DOE community waste remediation problems. Twenty-three Technical Task Plans (TTPs) have been identified to support this mission during FY-92; 10 of these have identified some support requirements when demonstrations take place. Section 1 of this report describes the tasks supported by BWID, determines if a technical demonstration is proposed, and if so, identifies the support requirements requested by the TTP Principal Investigators. Section 2 of this report is an evaluation identifying facility characteristics of existing Idaho National Engineering Laboratory (INEL) facilities that may be considered for use in BWID technology demonstration activities

  7. Accidents in nuclear facilities: classification, incidence and impact

    International Nuclear Information System (INIS)

    Galicia A, J.; Paredes G, L. C.

    2012-10-01

    A general analysis of the 146 accidents reported officially in nuclear facilities from 1945 to 2012 is presented, among them some took place in: power or research nuclear reactors, critical and subcritical nuclear assemblies, handling of nuclear materials inside laboratories belonging to institutes or universities, in radiochemistry industrial plants and nuclear fuel factories. In form graph the incidence of these accidents is illustrated classified for; category, decades, geographical localization, country classification before the OECD, failure type, and the immediate or later victims. On the other hand, the main learned lessons of the nuclear accidents of Three Mile Island, Chernobyl and Fukushima are stood out, among those that highlight; the human factors, the necessity of designs more innovative and major technology for the operation, control and surveillance of the nuclear facilities, to increase the criterions of nuclear, radiological and physics safety applied to these facilities, the necessity to carry out probabilistic analysis of safety more detailed for cases of not very probable accidents and their impact, to revalue the selection criterions of the sites for nuclear locations, the methodology of post-accident sites recovery and major instrumentation for parameters evaluation and the radiological monitoring among others. (Author)

  8. Hazard classification criteria for non-nuclear facilities

    International Nuclear Information System (INIS)

    Mahn, J.A.; Walker, S.A.

    1997-01-01

    Sandia National Laboratories' Integrated Risk Management Department has developed a process for establishing the appropriate hazard classification of a new facility or operation, and thus the level of rigor required for the associated authorization basis safety documentation. This process is referred to as the Preliminary Hazard Screen. DOE Order 5481.1B contains the following hazard classification for non-nuclear facilities: high--having the potential for onsite or offsite impacts to large numbers of persons or for major impacts to the environment; moderate--having the potential for considerable onsite impacts but only minor offsite impacts to people or the environment; low--having the potential for only minor onsite and negligible offsite impacts to people or the environment. It is apparent that the application of such generic criteria is more than likely to be fraught with subjective judgment. One way to remove the subjectivity is to define health and safety classification thresholds for specific hazards that are based on the magnitude of the hazard, rather than on a qualitative assessment of possible accident consequences. This paper presents the results of such an approach to establishing a readily usable set of non-nuclear facility hazard classifications

  9. Precision Clock Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Tests and evaluates high-precision atomic clocks for spacecraft, ground, and mobile applications. Supports performance evaluation, environmental testing,...

  10. Critical Evaluation of Headache Classifications.

    Science.gov (United States)

    Özge, Aynur

    2013-08-01

    Transforming a subjective sense like headache into an objective state and establishing a common language for this complaint which can be both a symptom and a disease all by itself have kept the investigators busy for years. Each recommendation proposed has brought along a set of patients who do not meet the criteria. While almost the most ideal and most comprehensive classification studies continued at this point, this time criticisims about withdrawing from daily practice came to the fore. In this article, the classification adventure of scientists who work in the area of headache will be summarized. More specifically, 2 classifications made by the International Headache Society (IHS) and the point reached in relation with the 3rd classification which is still being worked on will be discussed together with headache subtypes. It has been presented with the wish and belief that it will contribute to the readers and young investigators who are interested in this subject.

  11. Standoff Detection Technology Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Standoff Detection Technology Evaluation facility is the only one of its kind in the country and allows researchers to release a known amount of material while...

  12. Classification and methodical features of fitness and wellness facilities

    Directory of Open Access Journals (Sweden)

    Yu. I. Beliak

    2014-11-01

    Full Text Available Purpose : health and fitness use a large arsenal of different sports and physical activity. Development of fitness industry promotes its expansion and requires classification and methodological features that lead to the use of appropriate fitness programs. Material : more than 60 literature and video of 42 prestigious international fitness - conventions lessons were analyzed. Results : the evolution of species fitness and wellness, as well as the character used in those funds. Conclusions : as a means of improving classification attribute fitness appropriate to use their orientation, according to which they are divided into aerobic, strength exercises that promote flexibility and psychomotor coordination. The main methodological features fitness facilities are highlighted: the variety and interchangeability, clear regulation, the ability to transform, to exercise a selective effect on the body, the ability to solve a wide range of tasks, innovation.

  13. Evaluation methods for hospital facilities

    DEFF Research Database (Denmark)

    Fronczek-Munter, Aneta

    2013-01-01

    according to focus areas and proposes which evaluation methods to use in different building phases of healthcare facilities. Hospital evaluations with experts and users are also considered; their subjective view on space, function, technology, usability and aesthetics. Results & solutions: This paper...... presents the different methods for evaluating buildings in use in a new model, the Evaluation Focus Flower, and proposes which evaluation methods are suitable for various aims and building phases, i.e. which is giving best input for the initial briefing process of new hospital facilities with ambition...... of creating buildings with enhanced usability. Additionally various evaluation methods used in hospital cases in Denmark and Norway are presented. Involvement of users is proposed, not just in defining requirements but also in co-creation/design and evaluation of solutions. The theories and preliminary...

  14. Critical Evaluation of Headache Classifications

    OpenAIRE

    ?ZGE, Aynur

    2013-01-01

    Transforming a subjective sense like headache into an objective state and establishing a common language for this complaint which can be both a symptom and a disease all by itself have kept the investigators busy for years. Each recommendation proposed has brought along a set of patients who do not meet the criteria. While almost the most ideal and most comprehensive classification studies continued at this point, this time criticisims about withdrawing from daily practice came to the fore. I...

  15. Exercise evaluation and simulation facility

    International Nuclear Information System (INIS)

    Meitzler, W.D.; Jaske, R.T.

    1983-12-01

    The Exercise Evaluation and Simulation Facility (EESF) is a mini computer based system that will serve as a tool to aid FEMA in the evaluation of radiological emergency plans and preparedness around commercial nucler power facilities. The EESF integrates the following resources: a meteorological model, dose model, evacuation model, map information, and exercise information into a single system. Thus the user may access these various resources concurrently, and on completion display the results on a color graphic display or hardcopy unit. A unique capability made possible by the integration of these models is the computation of estimated total dose to the population

  16. Development of an auditable safety analysis in support of a radiological facility classification

    International Nuclear Information System (INIS)

    Kinney, M.D.; Young, B.

    1995-01-01

    In recent years, U.S. Department of Energy (DOE) facilities commonly have been classified as reactor, non-reactor nuclear, or nuclear facilities. Safety analysis documentation was prepared for these facilities, with few exceptions, using the requirements in either DOE Order 5481.1B, Safety Analysis and Review System; or DOE Order 5480.23, Nuclear Safety Analysis Reports. Traditionally, this has been accomplished by development of an extensive Safety Analysis Report (SAR), which identifies hazards, assesses risks of facility operation, describes and analyzes adequacy of measures taken to control hazards, and evaluates potential accidents and their associated risks. This process is complicated by analysis of secondary hazards and adequacy of backup (redundant) systems. The traditional SAR process is advantageous for DOE facilities with appreciable hazards or operational risks. SAR preparation for a low-risk facility or process can be cost-prohibitive and quite challenging because conventional safety analysis protocols may not readily be applied to a low-risk facility. The DOE Office of Environmental Restoration and Waste Management recognized this potential disadvantage and issued an EM limited technical standard, No. 5502-94, Hazard Baseline Documentation. This standard can be used for developing documentation for a facility classified as radiological, including preparation of an auditable (defensible) safety analysis. In support of the radiological facility classification process, the Uranium Mill Tailings Remedial Action (UMTRA) Project has developed an auditable safety analysis document based upon the postulation criteria and hazards analysis techniques defined in DOE Order 5480.23

  17. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  18. Critical Protection Item classification for a waste processing facility at Savannah River Site

    International Nuclear Information System (INIS)

    Ades, M.J.; Garrett, R.J.

    1993-01-01

    This paper describes the methodology for Critical Protection Item (CPI) classification and its application to the Structures, Systems and Components (SSC) of a waste processing facility at the Savannah River Site (SRS). The WSRC methodology for CPI classification includes the evaluation of the radiological and non-radiological consequences resulting from postulated accidents at the waste processing facility and comparison of these consequences with allowable limits. The types of accidents considered include explosions and fire in the facility and postulated accidents due to natural phenomena, including earthquakes, tornadoes, and high velocity straight winds. The radiological analysis results indicate that CPIs are not required at the waste processing facility to mitigate the consequences of radiological release. The non-radiological analysis, however, shows that the Waste Storage Tank (WST) and the dike spill containment structures around the formic acid tanks in the cold chemical feed area and waste treatment area of the facility should be identified as CPIs. Accident mitigation options are provided and discussed

  19. A comparative evaluation of sequence classification programs

    Directory of Open Access Journals (Sweden)

    Bazinet Adam L

    2012-05-01

    Full Text Available Abstract Background A fundamental problem in modern genomics is to taxonomically or functionally classify DNA sequence fragments derived from environmental sampling (i.e., metagenomics. Several different methods have been proposed for doing this effectively and efficiently, and many have been implemented in software. In addition to varying their basic algorithmic approach to classification, some methods screen sequence reads for ’barcoding genes’ like 16S rRNA, or various types of protein-coding genes. Due to the sheer number and complexity of methods, it can be difficult for a researcher to choose one that is well-suited for a particular analysis. Results We divided the very large number of programs that have been released in recent years for solving the sequence classification problem into three main categories based on the general algorithm they use to compare a query sequence against a database of sequences. We also evaluated the performance of the leading programs in each category on data sets whose taxonomic and functional composition is known. Conclusions We found significant variability in classification accuracy, precision, and resource consumption of sequence classification programs when used to analyze various metagenomics data sets. However, we observe some general trends and patterns that will be useful to researchers who use sequence classification programs.

  20. Hazard evaluation for 244-AR vault facility

    International Nuclear Information System (INIS)

    BRAUN, D.J.

    1999-01-01

    This document presents the results of a hazard identification and evaluation performed on the 244-AR Vault Facility to close a USQ (USQ No. TF-98-0785, Potential Inadequacy in Authorization Basis (PIAB): To Evaluate Miscellaneous Facilities Listed in HNF-2503 And Not Addressed In The TWRS Authorization Basis) that was generated as part of an evaluation of inactive TWRS facilities

  1. An evaluation of classification systems for stillbirth

    Directory of Open Access Journals (Sweden)

    Pattinson Robert

    2009-06-01

    Full Text Available Abstract Background Audit and classification of stillbirths is an essential part of clinical practice and a crucial step towards stillbirth prevention. Due to the limitations of the ICD system and lack of an international approach to an acceptable solution, numerous disparate classification systems have emerged. We assessed the performance of six contemporary systems to inform the development of an internationally accepted approach. Methods We evaluated the following systems: Amended Aberdeen, Extended Wigglesworth; PSANZ-PDC, ReCoDe, Tulip and CODAC. Nine teams from 7 countries applied the classification systems to cohorts of stillbirths from their regions using 857 stillbirth cases. The main outcome measures were: the ability to retain the important information about the death using the InfoKeep rating; the ease of use according to the Ease rating (both measures used a five-point scale with a score Results InfoKeep scores were significantly different across the classifications (p ≤ 0.01 due to low scores for Wigglesworth and Aberdeen. CODAC received the highest mean (SD score of 3.40 (0.73 followed by PSANZ-PDC, ReCoDe and Tulip [2.77 (1.00, 2.36 (1.21, 1.92 (1.24 respectively]. Wigglesworth and Aberdeen resulted in a high proportion of unexplained stillbirths and CODAC and Tulip the lowest. While Ease scores were different (p ≤ 0.01, all systems received satisfactory scores; CODAC received the highest score. Aberdeen and Wigglesworth showed poor agreement with kappas of 0.35 and 0.25 respectively. Tulip performed best with a kappa of 0.74. The remainder had good to fair agreement. Conclusion The Extended Wigglesworth and Amended Aberdeen systems cannot be recommended for classification of stillbirths. Overall, CODAC performed best with PSANZ-PDC and ReCoDe performing well. Tulip was shown to have the best agreement and a low proportion of unexplained stillbirths. The virtues of these systems need to be considered in the development of an

  2. An evaluation of classification systems for stillbirth.

    Science.gov (United States)

    Flenady, Vicki; Frøen, J Frederik; Pinar, Halit; Torabi, Rozbeh; Saastad, Eli; Guyon, Grace; Russell, Laurie; Charles, Adrian; Harrison, Catherine; Chauke, Lawrence; Pattinson, Robert; Koshy, Rachel; Bahrin, Safiah; Gardener, Glenn; Day, Katie; Petersson, Karin; Gordon, Adrienne; Gilshenan, Kristen

    2009-06-19

    Audit and classification of stillbirths is an essential part of clinical practice and a crucial step towards stillbirth prevention. Due to the limitations of the ICD system and lack of an international approach to an acceptable solution, numerous disparate classification systems have emerged. We assessed the performance of six contemporary systems to inform the development of an internationally accepted approach. We evaluated the following systems: Amended Aberdeen, Extended Wigglesworth; PSANZ-PDC, ReCoDe, Tulip and CODAC. Nine teams from 7 countries applied the classification systems to cohorts of stillbirths from their regions using 857 stillbirth cases. The main outcome measures were: the ability to retain the important information about the death using the InfoKeep rating; the ease of use according to the Ease rating (both measures used a five-point scale with a score <2 considered unsatisfactory); inter-observer agreement and the proportion of unexplained stillbirths. A randomly selected subset of 100 stillbirths was used to assess inter-observer agreement. InfoKeep scores were significantly different across the classifications (p < or = 0.01) due to low scores for Wigglesworth and Aberdeen. CODAC received the highest mean (SD) score of 3.40 (0.73) followed by PSANZ-PDC, ReCoDe and Tulip [2.77 (1.00), 2.36 (1.21), 1.92 (1.24) respectively]. Wigglesworth and Aberdeen resulted in a high proportion of unexplained stillbirths and CODAC and Tulip the lowest. While Ease scores were different (p < or = 0.01), all systems received satisfactory scores; CODAC received the highest score. Aberdeen and Wigglesworth showed poor agreement with kappas of 0.35 and 0.25 respectively. Tulip performed best with a kappa of 0.74. The remainder had good to fair agreement. The Extended Wigglesworth and Amended Aberdeen systems cannot be recommended for classification of stillbirths. Overall, CODAC performed best with PSANZ-PDC and ReCoDe performing well. Tulip was shown to have the

  3. 10 CFR 1045.9 - RD classification performance evaluation.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false RD classification performance evaluation. 1045.9 Section... classification performance evaluation. (a) Heads of agencies shall ensure that RD management officials and those... RD or FRD documents shall have their personnel performance evaluated with respect to classification...

  4. Safeguards Automated Facility Evaluation (SAFE) methodology

    International Nuclear Information System (INIS)

    Chapman, L.D.; Grady, L.M.; Bennett, H.A.; Sasser, D.W.; Engi, D.

    1978-08-01

    An automated approach to facility safeguards effectiveness evaluation has been developed. This automated process, called Safeguards Automated Facility Evaluation (SAFE), consists of a collection of a continuous stream of operational modules for facility characterization, the selection of critical paths, and the evaluation of safeguards effectiveness along these paths. The technique has been implemented on an interactive computer time-sharing system and makes use of computer graphics for the processing and presentation of information. Using this technique, a comprehensive evaluation of a safeguards system can be provided by systematically varying the parameters that characterize the physical protection components of a facility to reflect the perceived adversary attributes and strategy, environmental conditions, and site operational conditions. The SAFE procedure has broad applications in the nuclear facility safeguards field as well as in the security field in general. Any fixed facility containing valuable materials or components to be protected from theft or sabotage could be analyzed using this same automated evaluation technique

  5. Safeguards Automated Facility Evaluation (SAFE) methodology

    International Nuclear Information System (INIS)

    Chapman, L.D.; Grady, L.M.; Bennett, H.A.; Sasser, D.W.; Engi, D.

    1978-01-01

    The SAFE procedure is an efficient method of evaluating the physical protection system of a nuclear facility. Since the algorithms used in SAFE for path generation and evaluation are analytical, many paths can be evaluated with a modest investment in computer time. SAFE is easy to use because the information required is well-defined and the interactive nature of this procedure lends itself to straightforward operation. The modular approach that has been taken allows other functionally equivalent modules to be substituted as they become available. The SAFE procedure has broad applications in the nuclear facility safeguards field as well as in the security field in general. Any fixed facility containing valuable materials or components to be protected from theft or sabotage could be analyzed using this same automated evaluation technique

  6. Toxic chemical hazard classification and risk acceptance guidelines for use in DOE facilities. Revision 2

    International Nuclear Information System (INIS)

    Craig, D.K.; Davis, J.S.; Prowse, J.; Hoffman, P.W.

    1995-01-01

    The concentration-limit guidelines presented in this document apply to airborne releases of chemicals evaluated with respect to human health effects for the purposes of hazard classification and categorization, risk assessment and safety analysis. They apply to all DOE facilities and operations involving the use of potentially hazardous chemicals. The guidelines do not address other nonradiological hazards such as fire, pressure releases (including explosions), and chemical reactivity, but the guidelines are applicable to hazardous chemical releases resulting from these events. This report presents the subcommittee's evaluation and recommendations regarding analyses of accidentally released toxic chemicals. The premise upon which these recommendations are based is that the mechanism of action of toxic chemicals is fundamentally different from that associated with radionuclides, with the exception of carcinogens. The recommendations reported herein are restricted to the airborne pathway because in an accident scenario this typically represents the most immediately significant route of public exposure. However, the subcommittee recognizes that exposure to chemicals through other pathways, in particular waterborne, can have significant impacts on human health and the environment. Although there are a number of chemicals for which absorption through the skin can contribute measurably to the total dose in chronic (e.g., occupational) exposure situations, this pathway has not been considered for the acute exposure scenarios considered in this report. Later studies. will address these issues if it appears desirable

  7. Evaluation of multiple emission point facilities

    International Nuclear Information System (INIS)

    Miltenberger, R.P.; Hull, A.P.; Strachan, S.; Tichler, J.

    1988-01-01

    In 1970, the New York State Department of Environmental Conservation (NYSDEC) assumed responsibility for the environmental aspect of the state's regulatory program for by-product, source, and special nuclear material. The major objective of this study was to provide consultation to NYSDEC and the US NRC to assist NYSDEC in determining if broad-based licensed facilities with multiple emission points were in compliance with NYCRR Part 380. Under this contract, BNL would evaluate a multiple emission point facility, identified by NYSDEC, as a case study. The review would be a nonbinding evaluation of the facility to determine likely dispersion characteristics, compliance with specified release limits, and implementation of the ALARA philosophy regarding effluent release practices. From the data collected, guidance as to areas of future investigation and the impact of new federal regulations were to be developed. Reported here is the case study for the University of Rochester, Strong Memorial Medical Center and Riverside Campus

  8. Post-Occupancy Evaluation of Facilities Change

    NARCIS (Netherlands)

    van der Voordt, Theo; de Been, I.; Maarleveld, M.; Finch, E

    2012-01-01

    This chapter discusses possible aims, tools and deliverables of Post-Occupancy Evaluations (POE) (otherwise known as building-in-use studies), with a focus on interventions in supporting facilities. POE has a long tradition and has been applied in different fields (e.g. offices, educational

  9. [Evaluation of new and emerging health technologies. Proposal for classification].

    Science.gov (United States)

    Prados-Torres, J D; Vidal-España, F; Barnestein-Fonseca, P; Gallo-García, C; Irastorza-Aldasoro, A; Leiva-Fernández, F

    2011-01-01

    Review and develop a proposal for the classification of health technologies (HT) evaluated by the Health Technology Assessment Agencies (HTAA). Peer review of AETS of the previous proposed classification of HT. Analysis of their input and suggestions for amendments. Construction of a new classification. Pilot study with physicians. Andalusian Public Health System. Spanish HTAA. Experts from HTAA. Tutors of family medicine residents. HT Update classification previously made by the research team. Peer review by Spanish HTAA. Qualitative and quantitative analysis of responses. Construction of a new and pilot study based on 12 evaluation reports of the HTAA. We obtained 11 thematic categories that are classified into 6 major head groups: 1, prevention technology; 2, diagnostic technology; 3, therapeutic technologies; 4, diagnostic and therapeutic technologies; 5, organizational technology, and 6, knowledge management and quality of care. In the pilot there was a good concordance in the classification of 8 of the 12 reports reviewed by physicians. Experts agree on 11 thematic categories of HT. A new classification of HT with double entry (Nature and purpose of HT) is proposed. APPLICABILITY: According to experts, the classification of the work of the HTAA may represent a useful tool to transfer and manage knowledge. Moreover, an adequate classification of the HTAA reports would help clinicians and other potential users to locate them and this can facilitate their dissemination. Copyright © 2010 SECA. Published by Elsevier Espana. All rights reserved.

  10. Nuclear power plant simulation facility evaluation methodology

    International Nuclear Information System (INIS)

    Haas, P.M.; Carter, R.J.; Laughery, K.R. Jr.

    1985-01-01

    A methodology for evaluation of nuclear power plant simulation facilities with regard to their acceptability for use in the US Nuclear Regulatory Commission (NRC) operator licensing exam is described. The evaluation is based primarily on simulator fidelity, but incorporates some aspects of direct operator/trainee performance measurement. The panel presentation and paper discuss data requirements, data collection, data analysis and criteria for conclusions regarding the fidelity evaluation, and summarize the proposed use of direct performance measurment. While field testing and refinement of the methodology are recommended, this initial effort provides a firm basis for NRC to fully develop the necessary methodology

  11. The Constitution, waste facility performance standards, and radioactive waste classification: Is equal protection possible?

    Energy Technology Data Exchange (ETDEWEB)

    Eye, R.V. [Kansas Dept. of Health and Environment, Topeka, KS (United States)

    1993-03-01

    The process for disposal of so-called low-level radioactive waste is deadlocked at present. Supporters of the proposed near-surface facilities assert that their designs will meet minimum legal and regulatory standards currently in effect. Among opponents there is an overarching concern that the proposed waste management facilities will not isolate radiation from the biosphere for an adequate length of time. This clash between legal acceptability and a perceived need to protect the environment and public health by requiring more than the law demand sis one of the underlying reasons why the process is deadlocked. Perhaps the most exhaustive public hearing yet conducted on low-level radioactive waste management has recently concluded in Illinois. The Illinois Low-Level Radioactive Waste Disposal Facility Sitting Commission conducted 71 days of fact-finding hearings on the safety and suitability of a site near Martinsville, Illinois, to serve as a location for disposition of low-level radioactive waste. Ultimately, the siting commission rejected the proposed facility site for several reasons. However, almost all the reasons were related, to the prospect that, as currently conceived, the concrete barrier/shallow-land burial method will not isolate radioactive waste from the biosphere. This paper reviews the relevant legal framework of the radioactive waste classification system and will argue that it is inadequate for long-lived radionuclides. Next, the paper will present a case for altering the classification system based on high-level waste regulatory considerations.

  12. Evaluation of Nuclear Facility Decommissioning Projects program

    International Nuclear Information System (INIS)

    Baumann, B.L.

    1983-01-01

    The objective of the Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program is to provide the NRC licensing staff with data which will allow an assessment of radiation exposure during decommissioning and the implementation of ALARA techniques. The data will also provide information to determine the funding level necessary to ensure timely and safe decommissioning operations. Actual decommissioning costs, methods and radiation exposures are compared with those estimated by the Battelle-PNL and ORNL NUREGs on decommissioning. Exposure reduction techniques applied to decommissioning activities to meet ALARA objectives are described. The lessons learned concerning various decommissioning methods are evaluated

  13. An evaluation of classification algorithms for intrusion detection ...

    African Journals Online (AJOL)

    An evaluation of classification algorithms for intrusion detection. ... Log in or Register to get access to full text downloads. ... Most of the available IDSs use all the 41 features in the network to evaluate and search for intrusive pattern in which ...

  14. Seismic evaluation of existing nuclear facilities. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    Programmes for re-evaluation and upgrading of safety of existing nuclear facilities are presently under way in a number of countries around the world. An important component of these programmes is the re-evaluation of the seismic safety through definition of new seismic parameters at the site and evaluation of seismic capacity of structures, equipment and distribution systems following updated information and criteria. The Seminar is intended to provide a forum for the exchange of information and discussion of the state-of-the-art on seismic safety of nuclear facilities in operation or under construction. Both analytical and experimental techniques for the evaluation of seismic capacity of structures, equipment and distribution systems are discussed. Full scale and field tests of structures and components using shaking tables, mechanical exciters, explosive and shock tests, and ambient vibrations are included in the seminar programme with emphasis on recent case histories. Presentations at the Seminar also include analytical techniques for the determination of dynamic properties of soil-structure systems from experiments as well as calibration of numerical models. Methods and criteria for seismic margin assessment based on experience data obtained from the behaviour of structures and components in real earthquakes are discussed. Guidelines for defining technical requirements for capacity re-evaluation (i.e. acceptable behaviour limits and design and implementation of structure and components upgrades are also presented and discussed. The following topics were covered during 7 sessions: earthquake experience and seismic re-evaluation; country experience in seismic re-evaluation programme; generic WWER studies; analytical methods for seismic capacity re-evaluation; experimental methods for seismic capacity re-evaluation; case studies.

  15. Seismic evaluation of existing nuclear facilities. Proceedings

    International Nuclear Information System (INIS)

    1995-01-01

    Programmes for re-evaluation and upgrading of safety of existing nuclear facilities are presently under way in a number of countries around the world. An important component of these programmes is the re-evaluation of the seismic safety through definition of new seismic parameters at the site and evaluation of seismic capacity of structures, equipment and distribution systems following updated information and criteria. The Seminar is intended to provide a forum for the exchange of information and discussion of the state-of-the-art on seismic safety of nuclear facilities in operation or under construction. Both analytical and experimental techniques for the evaluation of seismic capacity of structures, equipment and distribution systems are discussed. Full scale and field tests of structures and components using shaking tables, mechanical exciters, explosive and shock tests, and ambient vibrations are included in the seminar programme with emphasis on recent case histories. Presentations at the Seminar also include analytical techniques for the determination of dynamic properties of soil-structure systems from experiments as well as calibration of numerical models. Methods and criteria for seismic margin assessment based on experience data obtained from the behaviour of structures and components in real earthquakes are discussed. Guidelines for defining technical requirements for capacity re-evaluation (i.e. acceptable behaviour limits and design and implementation of structure and components upgrades are also presented and discussed. The following topics were covered during 7 sessions: earthquake experience and seismic re-evaluation; country experience in seismic re-evaluation programme; generic WWER studies; analytical methods for seismic capacity re-evaluation; experimental methods for seismic capacity re-evaluation; case studies

  16. Using classification tree modelling to investigate drug prescription practices at health facilities in rural Tanzania

    Directory of Open Access Journals (Sweden)

    Kajungu Dan K

    2012-09-01

    Full Text Available Abstract Background Drug prescription practices depend on several factors related to the patient, health worker and health facilities. A better understanding of the factors influencing prescription patterns is essential to develop strategies to mitigate the negative consequences associated with poor practices in both the public and private sectors. Methods A cross-sectional study was conducted in rural Tanzania among patients attending health facilities, and health workers. Patients, health workers and health facilities-related factors with the potential to influence drug prescription patterns were used to build a model of key predictors. Standard data mining methodology of classification tree analysis was used to define the importance of the different factors on prescription patterns. Results This analysis included 1,470 patients and 71 health workers practicing in 30 health facilities. Patients were mostly treated in dispensaries. Twenty two variables were used to construct two classification tree models: one for polypharmacy (prescription of ≥3 drugs on a single clinic visit and one for co-prescription of artemether-lumefantrine (AL with antibiotics. The most important predictor of polypharmacy was the diagnosis of several illnesses. Polypharmacy was also associated with little or no supervision of the health workers, administration of AL and private facilities. Co-prescription of AL with antibiotics was more frequent in children under five years of age and the other important predictors were transmission season, mode of diagnosis and the location of the health facility. Conclusion Standard data mining methodology is an easy-to-implement analytical approach that can be useful for decision-making. Polypharmacy is mainly due to the diagnosis of multiple illnesses.

  17. Exploratory Shaft Facility quality assurance impact evaluation

    International Nuclear Information System (INIS)

    1987-08-01

    This report addresses the impact of the quality assurance practices used for the Exploratory Shaft Facility (ESF) design, and construction in licensing as part of the repository. Acceptance criteria used for evaluating the suitability of ESF QA practices are based on documents that had not been invoked for repository design or construction activities at the time of this evaluation. This report identifies the QA practices necessary for ESF design and construction licensability. A review and evaluation of QA practices for ESF design and construction resulted in the following conclusions. QA practices were found to be acceptable with a few exceptions. QA practices for construction activities were found to be insufficiently documented in implementing procedures to allow a full and effective evaluation for licensing purposes. Recommendations are provided for mitigating impacts to ensure compatibility of the QA practices with those considered necessary for repository licensing. 8 refs., 3 tabs

  18. Catalogue and classification of technical safety standards, rules and regulations for nuclear power reactors and nuclear fuel cycle facilities

    International Nuclear Information System (INIS)

    Fichtner, N.; Becker, K.; Bashir, M.

    1977-01-01

    The present report is an up-dated version of the report 'Catalogue and Classification of Technical Safety Rules for Light-water Reactors and Reprocessing Plants' edited under code No EUR 5362e, August 1975. Like the first version of the report, it constitutes a catalogue and classification of standards, rules and regulations on land-based nuclear power reactors and fuel cycle facilities. The reasons for the classification system used are given and discussed

  19. Pediatric urinary incontinence: Classification, evaluation, and ...

    African Journals Online (AJOL)

    A.J. Schaeffer

    tinuous incontinence refers to constant leakage of urine and can occur even in .... evaluation of pediatric urinary incontinence and guide which tests, if any, should ..... ments taken during bladder filling and storage include the maximal bladder ...

  20. Cold vacuum drying facility site evaluation report

    International Nuclear Information System (INIS)

    Diebel, J.A.

    1996-01-01

    In order to transport Multi-Canister Overpacks to the Canister Storage Building they must first undergo the Cold Vacuum Drying process. This puts the design, construction and start-up of the Cold Vacuum Drying facility on the critical path of the K Basin fuel removal schedule. This schedule is driven by a Tri-Party Agreement (TPA) milestone requiring all of the spent nuclear fuel to be removed from the K Basins by December, 1999. This site evaluation is an integral part of the Cold Vacuum Drying design process and must be completed expeditiously in order to stay on track for meeting the milestone

  1. Classification and evaluation of medical devices

    Directory of Open Access Journals (Sweden)

    Edina Vranić

    2003-05-01

    Full Text Available Medical devices and medical disposables contribute significantly to the quality and effectiveness of the health care system. It is necessary to commit scientifically sound regulatory environment that will provide consumers with the best medical care. This includes continued services to small manufacturers, readily available guidance on FDA requirements, predictable and reasonable response times on applications for marketing, and equitable enforcement. But in the public interest, this commitment to the industry must be coupled with a reciprocal commitment: that medical device firms will meet high standards in the design, manufacture, and evaluation of their products. The protections afforded our consumer, and the benefits provided the medical device industry, cannot be underestimated.

  2. Evaluation of low-level radioactive waste characterization and classification programs of the West Valley Demonstration Project

    International Nuclear Information System (INIS)

    Taie, K.R.

    1994-01-01

    The West Valley Demonstration Project (WVDP) is preparing to upgrade their low-level radioactive waste (LLW) characterization and classification program. This thesis describes a survey study of three other DOE sites conducted in support of this effort. The LLW characterization/classification programs of Oak Ridge National Laboratory, Savannah River Site, and Idaho National Engineering Laboratory were critically evaluated. The evaluation was accomplished through tours of each site facility and personnel interviews. Comparative evaluation of the individual characterization/classification programs suggests the WVDP should purchase a real-time radiography unit and a passive/active neutron detection system, make additional mechanical modifications to the segmented gamma spectroscopy assay system, provide a separate building to house characterization equipment and perform assays away from waste storage, develop and document a new LLW characterization/classification methodology, and make use of the supercompactor owned by WVDP

  3. Gamma irradiation facility: Evaluation of operational modes

    International Nuclear Information System (INIS)

    Adesanmi, C.A.; Ali, M.S.; Shonowo, O.A.; Akueche, E.C.; Sadare, O.O.; Mustapha, T.K.; Yusuf, U.; Inyanda, A.K.

    2007-01-01

    The multipurpose Gamma Irradiation Facility (GIF) at the Nuclear Technology Centre (NTC), Sheda Science and Technology Complex (SHETSCO), Abuja, Nigeria is designed as a semi-commercial plant with facilities for research and development (R and D). The design takes into account the different needs of the various research applications which require a wide dose range, a variety of techniques, different product sizes, shapes, mass, volume, densities and types. Programmable doses are used for food irradiation (0.04 - 10 kGy), biological seed mutation breeding and sterile insect technique (STI) (0.01- 5 kGy) sterilization of medical, pharmaceutical and cosmetic products and packages (up to 25 kGy) and cross-linking of polymers (up to 100 kGy). The six different modes of operations (sample elevator, stationary, swiveling, 2-path inner lane and 2-path outer lane and 4-path line) were evaluated. The dose range, mass range and range of irradiation time practicable were established and advantages for radiation processing of food and industrial products were enumerated for the six modes of operations for the first time

  4. Thermionic system evaluated test (TSET) facility description

    Science.gov (United States)

    Fairchild, Jerry F.; Koonmen, James P.; Thome, Frank V.

    1992-01-01

    A consortium of US agencies are involved in the Thermionic System Evaluation Test (TSET) which is being supported by the Strategic Defense Initiative Organization (SDIO). The project is a ground test of an unfueled Soviet TOPAZ-II in-core thermionic space reactor powered by electrical heat. It is part of the United States' national thermionic space nuclear power program. It will be tested in Albuquerque, New Mexico at the New Mexico Engineering Research Institute complex by the Phillips Laboratoty, Sandia National Laboratories, Los Alamos National Laboratory, and the University of New Mexico. One of TSET's many objectives is to demonstrate that the US can operate and test a complete space nuclear power system, in the electrical heater configuration, at a low cost. Great efforts have been made to help reduce facility costs during the first phase of this project. These costs include structural, mechanical, and electrical modifications to the existing facility as well as the installation of additional emergency systems to mitigate the effects of utility power losses and alkali metal fires.

  5. Materials evaluation for a transuranic processing facility

    International Nuclear Information System (INIS)

    Barker, S.A.; Schwenk, E.B.; Divine, J.R.

    1990-11-01

    The Westinghouse Hanford Company, with the assistance of the Pacific Northwest Laboratory, is developing a transuranium extraction process for preheating double-shell tank wastes at the Hanford Site to reduce the volume of transuranic waste being sent to a repository. The bench- scale transuranium extraction process development is reaching a stage where a pilot plant design has begun for the construction of a facility in the existing B Plant. Because of the potential corrosivity of neutralized cladding removal waste process streams, existing embedded piping alloys in B Plant are being evaluated and ''new'' alloys are being selected for the full-scale plant screening corrosion tests. Once the waste is acidified with HNO 3 , some of the process streams that are high in F - and low in Al and zr can produce corrosion rates exceeding 30,000 mil/yr in austenitic alloys. Initial results results are reported concerning the applicability of existing plant materials to withstand expected process solutions and conditions to help determine the feasibility of locating the plant at the selected facility. In addition, process changes are presented that should make the process solutions less corrosive to the existing materials. Experimental work confirms that Hastelloy B is unsatisfactory for the expected process solutions; type 304L, 347 and 309S stainless steels are satisfactory for service at room temperature and 60 degrees C, if process stream complexing is performed. Inconel 625 was satisfactory for all solutions. 17 refs., 5 figs., 8 tabs

  6. Design, Evaluation and Test Technology Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The mission of this facility, which is composed of numerous specialized facilities, is to provide capabilities to simulate a wide range of environments for component...

  7. Classification

    Science.gov (United States)

    Clary, Renee; Wandersee, James

    2013-01-01

    In this article, Renee Clary and James Wandersee describe the beginnings of "Classification," which lies at the very heart of science and depends upon pattern recognition. Clary and Wandersee approach patterns by first telling the story of the "Linnaean classification system," introduced by Carl Linnacus (1707-1778), who is…

  8. Possession States: Approaches to Clinical Evaluation and Classification

    Directory of Open Access Journals (Sweden)

    S. McCormick

    1992-01-01

    Full Text Available The fields of anthropology and sociology have produced a large quantity of literature on possession states, physicians however rarely report on such phenomena. As a result clinical description of possession states has suffered, even though these states may be more common and less deviant than supposed. Both ICD-10 and DSM-IV may include specific criteria for possession disorders. The authors briefly review Western notions about possession and kindred states and present guidelines for evaluation and classification.

  9. Comprehensive Evaluation and Classification of Interchange Diagrammatic Guide Signs’ Complexity

    OpenAIRE

    Li, Yang; Zhao, Xiaohua; He, Qing; Huang, Lihua; Rong, Jian

    2018-01-01

    The effectiveness of interchange diagrammatic guide signs has significant meaning in traffic safety and driver’s understanding. This paper presented a comprehensive evaluation and classification of interchange diagrammatic guide signs’ complexity. The effectiveness of interchange diagrammatic guide signs relies on how well road users can understand those diagrams. This study tested 37 types of diagrams on the visual recognition complexity degree in three levels, general level, partial level, ...

  10. Evaluation of interobserver agreement in Albertoni's classification for mallet finger

    Directory of Open Access Journals (Sweden)

    Vinícius Alexandre de Souza Almeida

    Full Text Available ABSTRACT Objective: To measure the reliability of Albertoni's classification for mallet finger. Methods: Agreement study. Forty-three radiographs of patients with mallet finger were assessed by 19 responders (12 hand surgeons and seven residents. Injuries were classified by Albertoni's classification. For agreement comparison, lesions were grouped as: (A tendon avulsion; (B avulsion fracture; (C fracture of the dorsal lip; and (D physis injury-and subgroups (each group divided into two subgroups. Agreement was assessed by Fleiss's modification for kappa statistics. Results: Agreement was excellent for Group A (k = 0.95 (0.93-0.97 and remained good when separated into A1 and A2. Group B was moderate (k = 0.42 (0.39-0.44 and poor when separated into B1 and B2. In the Group C, agreement was good (k = 0.72 (0.70-0.74, but when separated into C1 and C2, it became moderate. Group D was always poor (k = 0.16 (0.14-0.19. The general agreement was moderate, with (k = 0.57 (0.56-0.58. Conclusion: Albertoni's classification evaluated for interobserver agreement is considered a reproducible classification by the method used in the research.

  11. Empirical evaluation of data normalization methods for molecular classification.

    Science.gov (United States)

    Huang, Huei-Chung; Qin, Li-Xuan

    2018-01-01

    Data artifacts due to variations in experimental handling are ubiquitous in microarray studies, and they can lead to biased and irreproducible findings. A popular approach to correct for such artifacts is through post hoc data adjustment such as data normalization. Statistical methods for data normalization have been developed and evaluated primarily for the discovery of individual molecular biomarkers. Their performance has rarely been studied for the development of multi-marker molecular classifiers-an increasingly important application of microarrays in the era of personalized medicine. In this study, we set out to evaluate the performance of three commonly used methods for data normalization in the context of molecular classification, using extensive simulations based on re-sampling from a unique pair of microRNA microarray datasets for the same set of samples. The data and code for our simulations are freely available as R packages at GitHub. In the presence of confounding handling effects, all three normalization methods tended to improve the accuracy of the classifier when evaluated in an independent test data. The level of improvement and the relative performance among the normalization methods depended on the relative level of molecular signal, the distributional pattern of handling effects (e.g., location shift vs scale change), and the statistical method used for building the classifier. In addition, cross-validation was associated with biased estimation of classification accuracy in the over-optimistic direction for all three normalization methods. Normalization may improve the accuracy of molecular classification for data with confounding handling effects; however, it cannot circumvent the over-optimistic findings associated with cross-validation for assessing classification accuracy.

  12. Classification

    DEFF Research Database (Denmark)

    Hjørland, Birger

    2017-01-01

    This article presents and discusses definitions of the term “classification” and the related concepts “Concept/conceptualization,”“categorization,” “ordering,” “taxonomy” and “typology.” It further presents and discusses theories of classification including the influences of Aristotle...... and Wittgenstein. It presents different views on forming classes, including logical division, numerical taxonomy, historical classification, hermeneutical and pragmatic/critical views. Finally, issues related to artificial versus natural classification and taxonomic monism versus taxonomic pluralism are briefly...

  13. Technical Evaluation of Oak Ridge Filter Test Facility

    CERN Document Server

    Kriskovich, J R

    2002-01-01

    Two evaluations of the Oak Ridge Department of Energy (DOE) Filter Test Facility (FTF) were performed on December 11 and 12, 2001, and consisted of a quality assurance and a technical evaluation. This report documents results of the technical evaluation.

  14. Systematics of gamma-ray energy spectra for classification of workplaces around a nuclear facility

    International Nuclear Information System (INIS)

    Urabe, Itsumasa; Tsujimoto, Tadashi; Katsurayama, Kousuke

    1988-01-01

    Radiation dosimetry in workplaces has been carried out both for assurance of the doses complying with the acceptable values and for improvement of protection methods to minimise detriments of the exposed population. This means that it is very important not only to determine dosimetric quantities in workplaces but also to know features of radiation levels because information for radiation protection can often be derived from the radiometric quantities. Classification of workplaces based on the feature of gamma-ray energy spectra is one of the practical ways to realise radiation protection being taken into consideration of the radiometric quantities. Furthermore, demarcation of workplaces based on these radiometric quantities may be effective for improvement of radiation protection practice such as estimation of radiation doses, designing of radiation shields and other activities. From these points of view, gamma-ray energy spectra have been determined in various workplaces in nuclear facilities, and systematics of gamma-ray fields were tried for classification of workplaces on the basis of the feature appeared in health physical quantities such as effective dose equivalents and responses of dosemeters

  15. Evaluation of classification systems for nonspecific idiopathic orbital inflammation

    NARCIS (Netherlands)

    Bijlsma, Ward R.; van 't Hullenaar, Fleur C.; Mourits, Maarten P.; Kalmann, Rachel

    2012-01-01

    To systematically analyze existing classification systems for idiopathic orbital inflammation (IOI) and propose and test a new best practice classification system. A systematic literature search was conducted to find all studies that described and applied a classification system for IOI.

  16. Seismic evaluation of critical facilities at the Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Murray, R.C.; Tokarz, F.J.

    1976-01-01

    The performance of critical facilities at the Lawrence Livermore Laboratory (LLL) are being evaluated for severe earthquake loading. Facilities at Livermore, Site-300 and the Nevada Test Site are included in this study. These facilities are identified, the seismic criteria used for the analysis are indicated, the various methods used for structural analysis are discussed and a summary of the results of facilities analyzed to date are presented

  17. Auditable Safety Analysis and Final Hazard Classification for the 105-N Reactor Zone and 109-N Steam Generator Zone Facility

    International Nuclear Information System (INIS)

    Kloster, G.L.

    1998-07-01

    This document is a graded auditable safety analysis (ASA) and final hazard classification (FHC) for the Reactor/Steam Generator Zone Segment. The Reactor/Steam Generator Zone Segment, part of the N Reactor Complex, that is also known as the Reactor Building and Steam Generator Cells. The installation of the modifications described within to support surveillance and maintenance activities are to be completed by July 1, 1999. The surveillance and maintenance activities addressed within are assumed to continue for the next 15- 20 years, until the initiation of facility D ampersand D (i.e., Interim Safe Storage). The graded ASA in this document is in accordance with EDPI-4.30-01, Rev. 1, Safety Analysis Documentation, (BHI-DE-1) and is consistent with guidance provided by the U.S. Department of Energy. This ASA describes the hazards within the facility and evaluates the adequacy of the measures taken to reduce, control, or mitigate the identified hazards. This document also serves as the FHC for the Reactor/Steam Generator Zone Segment. This FHC is developed through the use of bounding accident analyses that envelope the potential exposures to personnel

  18. TWRS HLW interim storage facility search and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Calmus, R.B., Westinghouse Hanford

    1996-05-16

    The purpose of this study was to identify and provide an evaluation of interim storage facilities and potential facility locations for the vitrified high-level waste (HLW) from the Phase I demonstration plant and Phase II production plant. In addition, interim storage facilities for solidified separated radionuclides (Cesium and Technetium) generated during pretreatment of Phase I Low-Level Waste Vitrification Plant feed was evaluated.

  19. Non-Hodgkin lymphoma response evaluation with MRI texture classification

    Directory of Open Access Journals (Sweden)

    Heinonen Tomi T

    2009-06-01

    Full Text Available Abstract Background To show magnetic resonance imaging (MRI texture appearance change in non-Hodgkin lymphoma (NHL during treatment with response controlled by quantitative volume analysis. Methods A total of 19 patients having NHL with an evaluable lymphoma lesion were scanned at three imaging timepoints with 1.5T device during clinical treatment evaluation. Texture characteristics of images were analyzed and classified with MaZda application and statistical tests. Results NHL tissue MRI texture imaged before treatment and under chemotherapy was classified within several subgroups, showing best discrimination with 96% correct classification in non-linear discriminant analysis of T2-weighted images. Texture parameters of MRI data were successfully tested with statistical tests to assess the impact of the separability of the parameters in evaluating chemotherapy response in lymphoma tissue. Conclusion Texture characteristics of MRI data were classified successfully; this proved texture analysis to be potential quantitative means of representing lymphoma tissue changes during chemotherapy response monitoring.

  20. Central Facilities Area Sewage Lagoon Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Giesbrecht, Alan [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-01

    The Central Facilities Area (CFA) located in Butte County, Idaho at Idaho National Laboratory (INL) has an existing wastewater system to collect and treat sanitary wastewater and non contact cooling water from the facility. The existing treatment facility consists of three cells: Cell 1 has a surface area of 1.7 acres, Cell 2 has a surface area of 10.3 acres, and Cell 3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5 acre land application site that utilizes a center pivot irrigation sprinkler system. The purpose of this current study is to update the analysis and conclusions of the December 2013 study. In this current study, the new seepage rate and influent flow rate data have been used to update the calculations, model, and analysis.

  1. Classification and Quality Evaluation of Tobacco Leaves Based on Image Processing and Fuzzy Comprehensive Evaluation

    Science.gov (United States)

    Zhang, Fan; Zhang, Xinhong

    2011-01-01

    Most of classification, quality evaluation or grading of the flue-cured tobacco leaves are manually operated, which relies on the judgmental experience of experts, and inevitably limited by personal, physical and environmental factors. The classification and the quality evaluation are therefore subjective and experientially based. In this paper, an automatic classification method of tobacco leaves based on the digital image processing and the fuzzy sets theory is presented. A grading system based on image processing techniques was developed for automatically inspecting and grading flue-cured tobacco leaves. This system uses machine vision for the extraction and analysis of color, size, shape and surface texture. Fuzzy comprehensive evaluation provides a high level of confidence in decision making based on the fuzzy logic. The neural network is used to estimate and forecast the membership function of the features of tobacco leaves in the fuzzy sets. The experimental results of the two-level fuzzy comprehensive evaluation (FCE) show that the accuracy rate of classification is about 94% for the trained tobacco leaves, and the accuracy rate of the non-trained tobacco leaves is about 72%. We believe that the fuzzy comprehensive evaluation is a viable way for the automatic classification and quality evaluation of the tobacco leaves. PMID:22163744

  2. Automated approach to nuclear facility safeguards effectiveness evaluation

    International Nuclear Information System (INIS)

    1977-01-01

    Concern over the security of nuclear facilities has generated a need for a reliable, time efficient, and easily applied method of evaluating the effectiveness of safeguards systems. Such an evaluation technique could be used (1) by the Nuclear Regulatory Commission to evaluate a licensee's proposal, (2) to assess the security status of a system, or (3) to design and/or upgrade nuclear facilities. The technique should be capable of starting with basic information, such as the facility layout and performance parameters for physical protection components, and analyzing that information so that a reliable overall facility evaluation is obtained. Responding to this expressed need, an automated approach to facility safeguards effectiveness evaluation has been developed. This procedure consists of a collection of functional modules for facility characterization, critical path generation, and path evaluation combined into a continuous stream of operations. The technique has been implemented on an interactive computer-timesharing system and makes use of computer graphics for the handling and presentation of information. Using this technique a thorough facility evaluation can be made by systematically varying parameters that characterize the physical protection components of a facility according to changes in perceived adversary attributes and strategy, environmental conditions, and site status

  3. Facility/equipment performance evaluation using microcomputer simulation analysis

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.

    1985-08-01

    A computer simulation analysis model was developed at the Pacific Northwest Laboratory to assist in assuring the adequacy of the Monitored Retrievable Storage facility design to meet the specified spent nuclear fuel throughput requirements. The microcomputer-based model was applied to the analysis of material flow, equipment capability and facility layout. The simulation analysis evaluated uncertainties concerning both facility throughput requirements and process duration times as part of the development of a comprehensive estimate of facility performance. The evaluations provided feedback into the design review task to identify areas where design modifications should be considered

  4. Experimental Facilities for Performance Evaluation of Fast Reactor Components

    International Nuclear Information System (INIS)

    Chandramouli, S.; Kumar, V.A. Suresh; Shanmugavel, M.; Vijayakumar, G.; Vinod, V.; Noushad, I.B.; Babu, B.; Kumar, G. Padma; Nashine, B.K.; Rajan, K.K.

    2013-01-01

    Brief details about various experimental facilities catering to the testing and performance evaluation requirements of fast reactor components have been brought out. These facilities have been found to be immensely useful to continue research and development activities in the areas of component development and testing, sodium technology, thermal hydraulics and sodium instrumentation for the SFR’s. In addition new facilities which have been planned will be of great importance for the developmental activities related to future SFR’s

  5. Criticality Safety Evaluation of Hanford Tank Farms Facility

    Energy Technology Data Exchange (ETDEWEB)

    WEISS, E.V.

    2000-12-15

    Data and calculations from previous criticality safety evaluations and analyses were used to evaluate criticality safety for the entire Tank Farms facility to support the continued waste storage mission. This criticality safety evaluation concludes that a criticality accident at the Tank Farms facility is an incredible event due to the existing form (chemistry) and distribution (neutron absorbers) of tank waste. Limits and controls for receipt of waste from other facilities and maintenance of tank waste condition are set forth to maintain the margin subcriticality in tank waste.

  6. Criticality Safety Evaluation of Hanford Tank Farms Facility

    International Nuclear Information System (INIS)

    WEISS, E.V.

    2000-01-01

    Data and calculations from previous criticality safety evaluations and analyses were used to evaluate criticality safety for the entire Tank Farms facility to support the continued waste storage mission. This criticality safety evaluation concludes that a criticality accident at the Tank Farms facility is an incredible event due to the existing form (chemistry) and distribution (neutron absorbers) of tank waste. Limits and controls for receipt of waste from other facilities and maintenance of tank waste condition are set forth to maintain the margin subcriticality in tank waste

  7. Classification of High-Rise Residential Building Facilities: A Descriptive Survey on 170 Housing Scheme in Klang Valley

    Directory of Open Access Journals (Sweden)

    Abd Wahab Siti Rashidah Hanum

    2016-01-01

    Full Text Available High-rise residential building is a type of housing that has multi-dwelling units built on the same land. This type of housing has become popular each year in urban area due to the increasing cost of land. There are several common facilities provided in high-rise residential building. For example playground, swimming pool, gymnasium, 24 hours security system such as CCTV, access card and so on. Thus, maintenance works of the common facilities must be well organised. The purpose of this paper is to identify the classification of facilities provided at high rise residential building. The survey was done on 170 high-rise residential schemes by using stratified random sampling technique. The scope of this research is within Klang Valley area. This area is rapidly developed with high-rise residential building. The objective of this survey is to list down all the facilities provided in each sample of the schemes. The result, there are nine classification of facilities provided for high-rise residential building.

  8. Prediction of radionuclide inventory for the low-and intermediated-level radioactive waste disposal facility the radioactive waste classification

    International Nuclear Information System (INIS)

    Jung, Kang Il; Jeong, Noh Gyeom; Moon, Young Pyo; Jeong, Mi Seon; Park, Jin Beak

    2016-01-01

    To meet nuclear regulatory requirements, more than 95% individual radionuclides in the low- and intermediate-level radioactive waste inventory have to be identified. In this study, the radionuclide inventory has been estimated by taking the long-term radioactive waste generation, the development plan of disposal facility, and the new radioactive waste classification into account. The state of radioactive waste cumulated from 2014 was analyzed for various radioactive sources and future prospects for predicting the long-term radioactive waste generation. The predicted radionuclide inventory results are expected to contribute to secure the development of waste disposal facility and to deploy the safety case for its long-term safety assessment

  9. Evaluation of physical facilities and processing operations of major ...

    African Journals Online (AJOL)

    ... of these abattoirs were evaluated based on their presence and functional status. ... of safe and wholesome meat and meat products for human consumption. Keywords: Abattoir, Butcher, Meat, Physical facilities, Public health, Standard ...

  10. Niland Test Facility Startup Evaluation Task Force

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    The following team reports are included: systems, operation, control, and safety; instrumentation; brine chemistry and materials evaluation; reservoir assessment; environment; and contingency analysis. (MHR)

  11. Evaluating Past and Future USCG Use of Ohmsett Test Facility

    Science.gov (United States)

    2016-10-01

    of Pages 22 22. Price Evaluating Past and Future USCG Use of Ohmsett Test Facility iv UNCLAS//Public | | CG-926 RDC | M. Fitzpatrick, et al...Opportunity Skimming System WEC Wave energy converter Evaluating Past and Future USCG Use of Ohmsett Test Facility x UNCLAS//Public | | CG-926 RDC | M...Date Summary of Effort OCT-NOV 1993 Vessel of Opportunity Skimming System (VOSS) (5 Weeks) APR-JUN 1996 Spilled Oil Recovery System (SORS) (8 Weeks

  12. [Quality assurance of pain care in Austria : Classification of management facilities].

    Science.gov (United States)

    Jaksch, Wolfgang; Likar, Rudolf; Folkes, Erika; Machold, Klaus; Herbst, Friedrich; Pils, Katharina; Stippl, Peter; Lettner, Sandra; Alfons, Mildred; Crevenna, Richard; Wiederer, Christian; Dieber, Janina; Glehr, Reinhold

    2017-11-01

    In Austria there is no nationwide coverage of pain management, which meets even approximately international criteria. At present there are about 30 interdisciplinary pain management offices and clinics providing care according to a concept of the Austrian Pain Society (ÖSG), about 10 other outpatient pain clinics are located in district and country hospitals. A few years ago, there still were about 50 pain clinics. Yet closure of outpatient clinics and cost-cutting measures in the health sector jeopardize adequate pain relief for patients with chronic pain conditions.Hence, the supply of care for approx. 1.8 mio. Austrians with chronic pain is not guaranteed due to lack of a comprehensive demand planning of pain care facilities. Furthermore, existing structures such as specialized clinics or emergency services in hospitals are primarily based on the personal commitment of individuals. At present, the various centres for pain management in Austria are run with very different operating times, so that for 74% of the chronic pain patients the desired requirements for outpatient pain management are not met and about 50 full-time pain clinics are missing.Under the patronage of the Austrian Pain Society, various national specialist societies have defined the structure and quality criteria for pain management centres in Austria, include, among others, proof of training, cooperation in interdisciplinary teams or minimum number of new patients per year, depending on the classification of the institution.This stepwise concept of care provision for pain patients is intended as first step to help improve the care of pain patients in Austria!

  13. Relative evaluation on decommissioning accident scenarios of nuclear facilities

    International Nuclear Information System (INIS)

    Jeong, Kwan-Seong; Choi, Byung-Seon; Moon, Jei-Kwon; Hyun, Dong-Jun; Kim, Geun-Ho; Kim, Tae-Hyoung; Jo, Kyung-Hwa; Seo, Jae-Seok; Jeong, Seong-Young; Lee, Jung-Jun

    2012-01-01

    Highlights: ► This paper suggests relative importance on accident scenarios during decommissioning of nuclear facilities. ► The importance of scenarios can be performed by using AHP and Sugeno fuzzy method. ► The AHP and Sugeno fuzzy method guarantee reliability of the importance evaluation. -- Abstract: This paper suggests the evaluation method of relative importance on accident scenarios during decommissioning of nuclear facilities. The evaluation method consists of AHP method and Sugeno fuzzy integral method. This method will guarantee the reliability of relative importance evaluation for decommissioning accident scenarios.

  14. Construction accident narrative classification: An evaluation of text mining techniques.

    Science.gov (United States)

    Goh, Yang Miang; Ubeynarayana, C U

    2017-11-01

    Learning from past accidents is fundamental to accident prevention. Thus, accident and near miss reporting are encouraged by organizations and regulators. However, for organizations managing large safety databases, the time taken to accurately classify accident and near miss narratives will be very significant. This study aims to evaluate the utility of various text mining classification techniques in classifying 1000 publicly available construction accident narratives obtained from the US OSHA website. The study evaluated six machine learning algorithms, including support vector machine (SVM), linear regression (LR), random forest (RF), k-nearest neighbor (KNN), decision tree (DT) and Naive Bayes (NB), and found that SVM produced the best performance in classifying the test set of 251 cases. Further experimentation with tokenization of the processed text and non-linear SVM were also conducted. In addition, a grid search was conducted on the hyperparameters of the SVM models. It was found that the best performing classifiers were linear SVM with unigram tokenization and radial basis function (RBF) SVM with uni-gram tokenization. In view of its relative simplicity, the linear SVM is recommended. Across the 11 labels of accident causes or types, the precision of the linear SVM ranged from 0.5 to 1, recall ranged from 0.36 to 0.9 and F1 score was between 0.45 and 0.92. The reasons for misclassification were discussed and suggestions on ways to improve the performance were provided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Monitored retrievable storage facility site screening and evaluation report

    International Nuclear Information System (INIS)

    1985-05-01

    The Nuclear Waste Policy Act of 1982 directs the Department of Energy to ''complete a detailed study of the need for and feasibility of, and to submit to the Congress a proposal for, the construction of one or more monitored retrievable storage facilities for high level radioactive waste and spent nuclear fuel.'' The Act directs that the proposal includes site specific designs. Further, the proposal is to include, ''for the first such facility, at least three alternative sites and at least five alternative combinations of such proposed site and facility designs...'' as well as a recommendation of ''the combination among the alternatives that the Secretary deems preferable.'' An MRS Site Screening Task Force has been formed to help identify and evaluated potential MRS facility sites within a preferred region and with the application of a siting process and criteria developed by the DOE. The activities of the task force presented in this report includes: site screening (Sections 3, 4, and 5), the MRS facilities which are to be sited are described; the criteria, process and outcome of the screening process is presented; and descriptions of the candidate MRS facility sites are given, and site evaluations (Sections 6 through 9) where the rational for the site evaluations are presented, along with each evaluation and findings of the Task Force

  16. Monitored retrievable storage facility site screening and evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    1985-05-01

    The Nuclear Waste Policy Act of 1982 directs the Department of Energy to complete a detailed study of the need for and feasibility of, and to submit to the Congress a proposal for, the construction of one or more monitored retrievable storage facilities for high level radioactive waste and spent nuclear fuel.'' The Act directs that the proposal includes site specific designs. Further, the proposal is to include, for the first such facility, at least three alternative sites and at least five alternative combinations of such proposed site and facility designs...'' as well as a recommendation of the combination among the alternatives that the Secretary deems preferable.'' An MRS Site Screening Task Force has been formed to help identify and evaluated potential MRS facility sites within a preferred region and with the application of a siting process and criteria developed by the DOE. The activities of the task force presented in this report includes: site screening (Sections 3, 4, and 5), the MRS facilities which are to be sited are described; the criteria, process and outcome of the screening process is presented; and descriptions of the candidate MRS facility sites are given, and site evaluations (Sections 6 through 9) where the rational for the site evaluations are presented, along with each evaluation and findings of the Task Force.

  17. Test facilities for evaluating nuclear thermal propulsion systems

    International Nuclear Information System (INIS)

    Beck, D.F.; Allen, G.C.; Shipers, L.R.; Dobranich, D.; Ottinger, C.A.; Harmon, C.D.; Fan, W.C.; Todosow, M.

    1992-01-01

    Interagency panels evaluating nuclear thermal propulsion (NTP) development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and baseline performance of some of the major subsystems designed to support a proposed ground test complex for evaluating nuclear thermal propulsion fuel elements and engines being developed for the Space Nuclear Thermal Propulsion (SNTP) program. Some preliminary results of evaluating this facility for use in testing other NTP concepts are also summarized

  18. Evaluation verification facilities (EVF) at MINT: concept and implementation

    International Nuclear Information System (INIS)

    Mohamed Hairul Hasmoni; Abd Nassir Ibrahim; Ab Razak Hamzah

    2003-01-01

    EVF facilities and components available are described comprehensively. Objective of establishing EVF as a National Centre for non-destructive testing (NDT) are discussed for various activities of method and equipment validation, R and D on quantitative NDT technique, training and certification, and defect characterization. For a successful activity available at EVF, it is vital that industry participates through input of funding, sponsorship and knowledge sharing. The Malaysian Institute for Nuclear Technology Research (MINT) invested a lot in this facility and ready to share this facility under various mechanisms such as memorandum of understanding (MOU), memorandum of agreement (MOA), contract research or letter of agreement. The facility would be open to industry. Member of NDT community are welcomed to conduct trial and discuss particular areas of interest with others in the industry. Optimising the facility by utilising the facility available and adding new components would make EVF a national centre for NDT and centre of excellence. This paper reviews the concept and implementation of an Evaluation Verification Facility (EVF) at MINT. The types and designs of facilities available are described and characterised by usage NDT. (Author)

  19. Evaluation of scaling concepts for integral system test facilities

    International Nuclear Information System (INIS)

    Condie, K.G.; Larson, T.K.; Davis, C.B.

    1987-01-01

    A study was conducted by EG and G Idaho, Inc., to identify and technically evaluate potential concepts which will allow the U.S. Nuclear Regulatory Commission to maintain the capability to conduct future integral, thermal-hydraulic facility experiments of interest to light water reactor safety. This paper summarizes the methodology used in the study and presents a rankings for each facility concept relative to its ability to simulate phenomena identified as important in selected reactor transients in Babcock and Wilcox and Westinghouse large pressurized water reactors. Established scaling methodologies are used to develop potential concepts for scaled integral thermal-hydraulic experiment facilities. Concepts selected included: full height, full pressure water; reduced height, reduced pressure water; reduced height, full pressure water; one-tenth linear, full pressure water; and reduced height, full scaled pressure Freon. Results from this study suggest that a facility capable of operating at typical reactor operating conditions will scale most phenomena reasonably well. Local heat transfer phenomena is best scaled by the full height facility, while the reduced height facilities provide better scaling where multi-dimensional phenomena are considered important. Although many phenomena in facilities using Freon or water at nontypical pressure will scale reasonably well, those phenomena which are heavily dependent on quality can be distorted. Furthermore, relation of data produced in facilities operating with nontypical fluids or at nontypical pressures to large plants will be a difficult and time-consuming process

  20. Hazard classification methodology

    International Nuclear Information System (INIS)

    Brereton, S.J.

    1996-01-01

    This document outlines the hazard classification methodology used to determine the hazard classification of the NIF LTAB, OAB, and the support facilities on the basis of radionuclides and chemicals. The hazard classification determines the safety analysis requirements for a facility

  1. Validity evaluation of internal exposure in nuclear facility decommission

    International Nuclear Information System (INIS)

    Wang Xiaoli; Chen Dahua; You Zeyun

    2012-01-01

    During nuclear facility decommission under construction, it is very important for workers to wear respirator to avoid harm of Am aerosols. So the protection effect of respirator is very important. The protection effect of respirator was calculated and evaluated according to the data achieved from engineering practice. The result shows that the protection effect is better than target management value and the respirator is effective to protect workers from harm of Am aerosols. The respirator is applied to other nuclear facility decommission. (authors)

  2. Preliminary safety evaluation (PSE) for Sodium Storage Facility at the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Bowman, B.R.

    1994-01-01

    This evaluation was performed for the Sodium Storage Facility (SSF) which will be constructed at the Fast Flux Test Facility (FFTF) in the area adjacent to the South and West Dump Heat Exchanger (DHX) pits. The purpose of the facility is to allow unloading the sodium from the FFTF plant tanks and piping. The significant conclusion of this Preliminary Safety Evaluation (PSE) is that the only Safety Class 2 components are the four sodium storage tanks and their foundations. The building, because of its imminent risk to the tanks under an earthquake or high winds, will be Safety Class 3/2, which means the building has a Safety Class 3 function with the Safety Class 2 loads of seismic and wind factored into the design

  3. Defense-in-depth evaluation for the New Waste Transfer Facility

    International Nuclear Information System (INIS)

    Hayes, T.G.; Kelly, J.L.

    1995-01-01

    This report fulfills part of the requirements of References 2 and 3 by documenting a Defense-In-Depth evaluation for the New Waste Transfer Facility (NWTF). This evaluation was performed using methodology similar to that used in an evaluation for the Defense Waste Processing Facility (DWPF). It differs because the DWPF evaluation was based on an existing Process Hazards Analysis (PHA) while NWTF's is based on a Preoperational Process Hazards Review (PHR) (Ref. 1). The accidents in the Process Hazards Review (PHR) were reviewed to determine those that might have significant consequences. Significance was based on the findings of the PHR, The facility design was reviewed to determine the Structures, Systems, and Components (SSCs) and administrative controls available before and after each accident. From this was developed a list of the Lines of Defense (LODs) available to contain the hazard associated with the accident. A summary of these LODs is given in Appendix C. Items are tabulated that are suggested for consideration in the functional classification as worker protection items. The specific criteria used in the evaluation is given in the methodology section of this report. The results are documented in Appendices A, B, C, and D

  4. Risk evaluation system for facility safeguards and security planning

    International Nuclear Information System (INIS)

    Udell, C.J.; Carlson, R.L.

    1987-01-01

    The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planing assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily

  5. Risk evaluation system for facility safeguards and security planning

    International Nuclear Information System (INIS)

    Udell, C.J.; Carlson, R.L.

    1987-01-01

    The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planning assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily

  6. A Soft Intelligent Risk Evaluation Model for Credit Scoring Classification

    Directory of Open Access Journals (Sweden)

    Mehdi Khashei

    2015-09-01

    Full Text Available Risk management is one of the most important branches of business and finance. Classification models are the most popular and widely used analytical group of data mining approaches that can greatly help financial decision makers and managers to tackle credit risk problems. However, the literature clearly indicates that, despite proposing numerous classification models, credit scoring is often a difficult task. On the other hand, there is no universal credit-scoring model in the literature that can be accurately and explanatorily used in all circumstances. Therefore, the research for improving the efficiency of credit-scoring models has never stopped. In this paper, a hybrid soft intelligent classification model is proposed for credit-scoring problems. In the proposed model, the unique advantages of the soft computing techniques are used in order to modify the performance of the traditional artificial neural networks in credit scoring. Empirical results of Australian credit card data classifications indicate that the proposed hybrid model outperforms its components, and also other classification models presented for credit scoring. Therefore, the proposed model can be considered as an appropriate alternative tool for binary decision making in business and finance, especially in high uncertainty conditions.

  7. Evaluating building performance in healthcare facilities: an organizational perspective.

    Science.gov (United States)

    Steinke, Claudia; Webster, Lynn; Fontaine, Marie

    2010-01-01

    Using the environment as a strategic tool is one of the most cost-effective and enduring approaches for improving public health; however, it is one that requires multiple perspectives. The purpose of this article is to highlight an innovative methodology that has been developed for conducting comprehensive performance evaluations in public sector health facilities in Canada. The building performance evaluation methodology described in this paper is a government initiative. The project team developed a comprehensive building evaluation process for all new capital health projects that would respond to the aforementioned need for stakeholders to be more accountable and to better integrate the larger organizational strategy of facilities. The Balanced Scorecard, which is a multiparadigmatic, performance-based business framework, serves as the underlying theoretical framework for this initiative. It was applied in the development of the conceptual model entitled the Building Performance Evaluation Scorecard, which provides the following benefits: (1) It illustrates a process to link facilities more effectively to the overall mission and goals of an organization; (2) It is both a measurement and a management system that has the ability to link regional facilities to measures of success and larger business goals; (3) It provides a standardized methodology that ensures consistency in assessing building performance; and (4) It is more comprehensive than traditional building evaluations. The methodology presented in this paper is both a measurement and management system that integrates the principles of evidence-based design with the practices of pre- and post-occupancy evaluation. It promotes accountability and continues throughout the life cycle of a project. The advantage of applying this framework is that it engages health organizations in clarifying a vision and strategy for their facilities and helps translate those strategies into action and measurable performance

  8. Monitored retrievable storage facility site screening and evaluation report

    International Nuclear Information System (INIS)

    1985-05-01

    The Nuclear Waste Policy Act of 1982 directs the Department of Energy to ''complete a detailed study of the need for and feasibility of, and to submit to the Congress a proposal for, the construction of one or more monitored retrievable storage facilities for high level radioactive waste and spent nuclear fuel.'' The Act directs that the proposal includes site specific designs. Further, the proposal is to include, ''for the first such facility, at least three alternative sites and at least five alternative combinations of such proposed sites and facility designs hor-ellipsis'' as well as a recommendation of ''the combination among the alternatives that the Secretary deems preferable.'' An MRS Site Screening Task Force has been formed to help identify and evaluate potential MRS facility sites within a preferred region and with the application of a siting process and criteria developed by the DOE. The activities of the Task Force presented in this report include: site evaluations (sections 10 through 12) where the rationale for the site evaluations are presented, along with each evaluation and findings of the Task Force. This in Volume 2 of a three volume document

  9. Monitored Retrievable Storage facility site screening and evaluation report

    International Nuclear Information System (INIS)

    1985-05-01

    The Nuclear Waste Policy Act of 1982 directs the Department of Energy to ''complete a detailed study of the need for and feasibility of, and to submit to the Congress a proposal for, the construction of one or more monitored retrievable storage facilities for high level radioactive waste and spent nuclear fuel.'' The Act directs that the proposal includes site specific designs. Further, the proposal is to include, ''for the first such facility, at least three alternative sites and at least five alternative combinations of such proposed sites and facility designs hor-ellipsis'' as well as a recommendation of ''the combination among the alternatives that the Secretary deems preferable.'' An MRS Site Screening Task Force has been formed to help identify and evaluate potential MRS facility sites within a preferred region and with the application of a siting process and criteria developed by the DOE. The activities of the Task Force presented in this report, all site evaluations (sections 13 through 16) where the rationale for the site evaluations are presented, along with each evaluation and findings of the Task Force. This is Volume 3 of a three volume document. References are also included in this volume

  10. Monitored retrievable storage facility site screening and evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    1985-05-01

    The Nuclear Waste Policy Act of 1982 directs the Department of Energy to complete a detailed study of the need for and feasibility of, and to submit to the Congress a proposal for, the construction of one or more monitored retrievable storage facilities for high level radioactive waste and spent nuclear fuel.'' The Act directs that the proposal includes site specific designs. Further, the proposal is to include, for the first such facility, at least three alternative sites and at least five alternative combinations of such proposed sites and facility designs{hor ellipsis}'' as well as a recommendation of the combination among the alternatives that the Secretary deems preferable.'' An MRS Site Screening Task Force has been formed to help identify and evaluate potential MRS facility sites within a preferred region and with the application of a siting process and criteria developed by the DOE. The activities of the Task Force presented in this report include: site evaluations (sections 10 through 12) where the rationale for the site evaluations are presented, along with each evaluation and findings of the Task Force. This in Volume 2 of a three volume document.

  11. Monitored Retrievable Storage facility site screening and evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    1985-05-01

    The Nuclear Waste Policy Act of 1982 directs the Department of Energy to complete a detailed study of the need for and feasibility of, and to submit to the Congress a proposal for, the construction of one or more monitored retrievable storage facilities for high level radioactive waste and spent nuclear fuel.'' The Act directs that the proposal includes site specific designs. Further, the proposal is to include, for the first such facility, at least three alternative sites and at least five alternative combinations of such proposed sites and facility designs {hor ellipsis}'' as well as a recommendation of the combination among the alternatives that the Secretary deems preferable.'' An MRS Site Screening Task Force has been formed to help identify and evaluate potential MRS facility sites within a preferred region and with the application of a siting process and criteria developed by the DOE. The activities of the Task Force presented in this report, all site evaluations (sections 13 through 16) where the rationale for the site evaluations are presented, along with each evaluation and findings of the Task Force. This is Volume 3 of a three volume document. References are also included in this volume.

  12. Evaluation of seismic criteria used in design of INEL facilities

    International Nuclear Information System (INIS)

    Young, G.A.

    1977-01-01

    This report provides the results of an independent evaluation of seismic studies that were made to establish the seismic acceleration levels and the response spectra used in the design of vital facilities at Idaho National Engineering Laboratory. A comparison of the procedures used to define the seismic acceleration values and response spectra at INEL with the requirements of the Nuclear Regulatory Commission showed that additional geologic studies would probably be required in order to fulfill NRC regulations. Recommendations are made on justifiable changes in the acceleration values and response spectra used at INEL. The geologic, geophysical, and seismological studies needed to provide a better understanding of the tectonic processes in the Snake River plains and the surrounding region are identified. Both potential and historical acceleration values are evaluated on a probability basis to permit a risk assessment approach to the design of new facilities and facility modifications. Studies conducted to develop seismic criteria for the design of the Loss of Fluid Test reactor and the New Waste Calcining Facility were selected as typical examples of criteria development previously used in the design of INEL facilities

  13. Evaluation of existing United States' facilities for use as a mixed-oxide (MOX) fuel fabrication facility for plutonium disposition

    International Nuclear Information System (INIS)

    Beard, C.A.; Buksa, J.J.; Chidester, K.; Eaton, S.L.; Motley, F.E.; Siebe, D.A.

    1995-01-01

    A number of existing US facilities were evaluated for use as a mixed-oxide fuel fabrication facility for plutonium disposition. These facilities include the Fuels Material Examination Facility (FMEF) at Hanford, the Washington Power Supply Unit 1 (WNP-1) facility at Hanford, the Barnwell Nuclear Fuel Plant (BNFP) at Barnwell, SC, the Fuel Processing Facility (FPF) at Idaho National Engineering Laboratory (INEL), the Device Assembly Facility (DAF) at the Nevada Test Site (NTS), and the P-reactor at the Savannah River Site (SRS). The study consisted of evaluating each facility in terms of available process space, available building support systems (i.e., HVAC, security systems, existing process equipment, etc.), available regional infrastructure (i.e., emergency response teams, protective force teams, available transportation routes, etc.), and ability to integrate the MOX fabrication process into the facility in an operationally-sound manner that requires a minimum amount of structural modifications

  14. Evaluation of Current Approaches to Stream Classification and a Heuristic Guide to Developing Classifications of Integrated Aquatic Networks

    Science.gov (United States)

    Melles, S. J.; Jones, N. E.; Schmidt, B. J.

    2014-03-01

    Conservation and management of fresh flowing waters involves evaluating and managing effects of cumulative impacts on the aquatic environment from disturbances such as: land use change, point and nonpoint source pollution, the creation of dams and reservoirs, mining, and fishing. To assess effects of these changes on associated biotic communities it is necessary to monitor and report on the status of lotic ecosystems. A variety of stream classification methods are available to assist with these tasks, and such methods attempt to provide a systematic approach to modeling and understanding complex aquatic systems at various spatial and temporal scales. Of the vast number of approaches that exist, it is useful to group them into three main types. The first involves modeling longitudinal species turnover patterns within large drainage basins and relating these patterns to environmental predictors collected at reach and upstream catchment scales; the second uses regionalized hierarchical classification to create multi-scale, spatially homogenous aquatic ecoregions by grouping adjacent catchments together based on environmental similarities; and the third approach groups sites together on the basis of similarities in their environmental conditions both within and between catchments, independent of their geographic location. We review the literature with a focus on more recent classifications to examine the strengths and weaknesses of the different approaches. We identify gaps or problems with the current approaches, and we propose an eight-step heuristic process that may assist with development of more flexible and integrated aquatic classifications based on the current understanding, network thinking, and theoretical underpinnings.

  15. Seismic evaluation of the LLNL plutonium facility (Building 332)

    International Nuclear Information System (INIS)

    Hall, W.J.; Sozen, M.A.

    1982-03-01

    The expected performance of the Lawrence Livermore National Laboratory (LLNL) Plutonium Facility (Building 332) subjected to earthquake ground motion has been evaluated. Anticipated behavior of the building, glove boxes, ventilation system and other systems critical for containment of plutonium is described for three severe postulated earthquake excitations. Based upon this evaluation, some damage to the building, glove boxes and ventilation system would be expected but no collapse of any structure is anticipated as a result of the postulated earthquake ground motions

  16. 105-DR Large Sodium Fire Facility closure activities evaluation report

    International Nuclear Information System (INIS)

    Adler, J.G.

    1996-01-01

    This report evaluates the closure activities at the 105-DR Large Sodium Fire Facility. The closure activities discussed include: the closure activities for the structures, equipment, soil, and gravel scrubber; decontamination methods; materials made available for recycling or reuse; and waste management. The evaluation compares these activities to the regulatory requirements and closure plan requirements. The report concludes that the areas identified in the closure plan can be clean closed

  17. Development of a methodology for safety classification on a non-reactor nuclear facility illustrated using an specific example

    International Nuclear Information System (INIS)

    Scheuermann, F.; Lehradt, O.; Traichel, A.

    2015-01-01

    To realize the safety of personnel and environment systems and components of nuclear facilities are classified according to their potential danger into safety classes. Based on this classification different demands on the manufacturing quality result. The objective of this work is to present the standardized method developed by NUKEM Technologies Engineering Services for the categorization into the safety classes restricted to Non-reactor nuclear facilities (NRNF). Exemplary the methodology is used on the complex Russian normative system (four safety classes). For NRNF only the lower two safety classes are relevant. The classification into the lowest safety class 4 is accordingly if the maximum resulting dose following from clean-up actions in case of incidents/accidents remains below 20 mSv and the volume activity restrictions of set in NRB-99/2009 are met. The methodology is illustrated using an example. In short the methodology consists of: - Determination of the working time to remove consequences of incidents, - Calculation of the dose resulting from direct radiation and due to inhalation during these works. The application of this methodology avoids over-conservative approaches. As a result some previously higher classified equipment can be classified into the lower safety class.

  18. Modeling and evaluating repeatability and reproducibility of ordinal classifications

    NARCIS (Netherlands)

    de Mast, J.; van Wieringen, W.N.

    2010-01-01

    This paper argues that currently available methods for the assessment of the repeatability and reproducibility of ordinal classifications are not satisfactory. The paper aims to study whether we can modify a class of models from Item Response Theory, well established for the study of the reliability

  19. Determinants of Integrated Management of Childhood Illness (IMCI) non-severe pneumonia classification and care in Malawi health facilities: Analysis of a national facility census.

    Science.gov (United States)

    Johansson, Emily White; Nsona, Humphreys; Carvajal-Aguirre, Liliana; Amouzou, Agbessi; Hildenwall, Helena

    2017-12-01

    Research shows inadequate Integrated Management of Childhood Illness (IMCI)-pneumonia care in various low-income settings but evidence is largely from small-scale studies with limited evidence of patient-, provider- and facility-levels determinants of IMCI non-severe pneumonia classification and its management. The Malawi Service Provision Assessment 2013-2014 included 3149 outpatients aged 2-59 months with completed observations, interviews and re-examinations. Mixed-effects logistic regression models quantified the influence of patient-, provider and facility-level determinants on having IMCI non-severe pneumonia and its management in observed consultations. Among 3149 eligible outpatients, 590 (18.7%) had IMCI non-severe pneumonia classification in re-examination. 228 (38.7%) classified cases received first-line antibiotics and 159 (26.9%) received no antibiotics. 18.6% with cough or difficult breathing had 60-second respiratory rates counted during consultations, and conducting this assessment was significantly associated with IMCI training ever received (odds ratio (OR) = 2.37, 95% confidence interval (CI): 1.29-4.31) and negative rapid diagnostic test results (OR = 3.21, 95% CI: 1.45-7.13). Older children had lower odds of assessments than infants (OR = 48-59 months: 0.35, 95% CI: 0.16-0.75). Children presenting with any of the following complaints also had reduced odds of assessment: fever, diarrhea, skin problem or any danger sign. First-line antibiotic treatment for classified cases was significantly associated with high temperatures (OR = 3.26, 95% CI: 1.24-8.55) while older children had reduced odds of first-line treatment compared to infants (OR = 48-59 months: 0.29, 95% CI: 0.10-0.83). RDT-confirmed malaria was a significant predictor of no antibiotic receipt for IMCI non-severe pneumonia (OR = 10.65, 95% CI: 2.39-47.36). IMCI non-severe pneumonia care was sub-optimal in Malawi health facilities in 2013-2014 with inadequate

  20. Switch evaluation test system for the National Ignition Facility

    International Nuclear Information System (INIS)

    Savage, M.E.; Simpson, W.W.; Reynolds, F.D.

    1997-01-01

    Flashlamp pumped lasers use pulsed power switches to commute energy stored in capacitor banks to the flashlamps. The particular application in which the authors are interested is the National Ignition Facility (NIF), being designed by Lawrence Livermore National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratories (SNL). To lower the total cost of these switches, SNL has a research program to evaluate large closing switches. The target value of the energy switched by a single device is 1.6 MJ, from a 6 mF, 24kV capacitor bank. The peak current is 500 kA. The lifetime of the NIF facility is 24,000 shots. There is no switch today proven at these parameters. Several short-lived switches (100's of shots) exist that can handle the voltage and current, but would require maintenance during the facility life. Other type devices, notably ignitrons, have published lifetimes in excess of 20,000 shots, but at lower currents and shorter pulse widths. The goal of the experiments at SNL is to test switches with the full NIF wave shape, and at the correct voltage. The SNL facility can provide over 500 kA at 24 kV charge voltage. the facility has 6.4 mF total capacitance, arranged in 25 sub-modules. the modular design makes the facility more flexible (for possible testing at lower current) and safer. For pulse shaping (the NIF wave shape is critically damped) there is an inductor and resistor for each of the 25 modules. Rather than one large inductor and resistor, this lowers the current in the pulse shaping components, and raises their value to those more easily attained with lumped inductors and resistors. The authors show the design of the facility, and show results from testing conducted thus far. They also show details of the testing plan for high current switches

  1. Test facility for the evaluation of microwave transmission components

    International Nuclear Information System (INIS)

    Fong, C.G.; Poole, B.R.

    1985-01-01

    A Low Power Test Facility (LPTF) was developed to evaluate the performance of Electron Cyclotron Resonance Heating (ECRH) microwave transmission components for the Mirror Fusion Test Facility (MFTF-B). The facility generates 26 to 60 GHz in modes of TE 01 , TE 02 , or TE 03 launched at power levels of 1/2 milliwatt. The propagation of the rf as it radiates from either transmitting or secondary reflecting microwave transmission components is recorded by a discriminating crystal detector mechanically manipulated at constant radius in spherical coordinates. The facility is used to test, calibrate, and verify the design of overmoded, circular waveguide components, quasi-optical reflecting elements before high power use. The test facility consists of microwave sources and metering components, such as VSWR, power and frequency meters, a rectangular TE 10 to circular TE 01 mode transducer, mode filter, circular TE 01 to 2.5 in. diameter overmoded waveguide with mode converters for combination of TE 01 to TE 03 modes. This assembly then connects to a circular waveguide launcher or the waveguide component under test

  2. Risk classification for nuclear facilities in connection with the illegal use of nuclear materials

    International Nuclear Information System (INIS)

    Bahm, W.; Naegele, G.; Sellinschegg, D.

    1976-01-01

    It is shown, and illustrated by an example, that specific conditions at a nuclear facility to a large extent determine the probability of a successful illegal attack against that facility. Therefore, a categorization of nuclear materials according to the associated hazards alone, as practised currently, does not appear to be sufficient for the establishment of a balanced national physical protection system. In this paper a possible way of categorizing nuclear facilities according to the associated risks, determined as objectively as possible, is discussed. It is felt that initially the analysis should be restricted to the determination of the conditional risks, associated with illegal acquisition and use of radioactive materials by a postulated hostile or similar group. (author)

  3. Physical Sciences Facility Air Emission Control Equivalency Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, David M.; Belew, Shan T.

    2008-10-17

    This document presents the adequacy evaluation for the application of technology standards during design, fabrication, installation and testing of radioactive air exhaust systems at the Physical Sciences Facility (PSF), located on the Horn Rapids Triangle north of the Pacific Northwest National Laboratory (PNNL) complex. The analysis specifically covers the exhaust portion of the heating, ventilation and air conditioning (HVAC) systems associated with emission units EP-3410-01-S, EP-3420-01-S and EP 3430-01-S.

  4. Evaluation of mercury in the liquid waste processing facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Vijay [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Shah, Hasmukh [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Occhipinti, John E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Wilmarth, William R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, Richard E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-08-13

    This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.

  5. Automated otolith image classification with multiple views: an evaluation on Sciaenidae.

    Science.gov (United States)

    Wong, J Y; Chu, C; Chong, V C; Dhillon, S K; Loh, K H

    2016-08-01

    Combined multiple 2D views (proximal, anterior and ventral aspects) of the sagittal otolith are proposed here as a method to capture shape information for fish classification. Classification performance of single view compared with combined 2D views show improved classification accuracy of the latter, for nine species of Sciaenidae. The effects of shape description methods (shape indices, Procrustes analysis and elliptical Fourier analysis) on classification performance were evaluated. Procrustes analysis and elliptical Fourier analysis perform better than shape indices when single view is considered, but all perform equally well with combined views. A generic content-based image retrieval (CBIR) system that ranks dissimilarity (Procrustes distance) of otolith images was built to search query images without the need for detailed information of side (left or right), aspect (proximal or distal) and direction (positive or negative) of the otolith. Methods for the development of this automated classification system are discussed. © 2016 The Fisheries Society of the British Isles.

  6. Occupational exposure assessment in a radioactive facility: a preliminary evaluation

    International Nuclear Information System (INIS)

    Alves, Alice dos Santos; Gerulis, Eduardo; Sanches, Matias P.; Carneiro, Janete C.G.G.

    2013-01-01

    The risk that a worker has found on the job is a function of the hazards present and his exposure level to those hazards. Exposure and risk assessment is therefore the heart of all occupational health and industrial hygiene programs involving a continuous process of information gathering. The use of a systematic method to characterize workplace exposures to chemical, physical and biological risks is a fundamental part of this process. This study aims to carry out a preliminary evaluation in a radioactive facility, identifying potential exposures and consequently the existing occupational hazards (risk/agent) in the workplace which the employee is subject. The study is based on proposal to carry out a basic characterization of the facility, which could be the first step in the investigation of occupational exposure. For this study was essential to know the workplace, potential risks and agents; workforce profile including assignment of tasks, sources of exposure processes, and control measures. The main tool used in this study was based on references, records, standards, procedures, interviews with the workers and with management. Since the basic characterization of the facility has been carried out, consequently the potential exposure to the agents of risks to workers has been identified. The study provided an overview of the perception of risk founded at facility studied. It is expected to contribute with the occupational health program resources for welfare of the worker. (author)

  7. Occupational exposure assessment in a radioactive facility: a preliminary evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Alice dos Santos; Gerulis, Eduardo; Sanches, Matias P.; Carneiro, Janete C.G.G., E-mail: alicesante@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The risk that a worker has found on the job is a function of the hazards present and his exposure level to those hazards. Exposure and risk assessment is therefore the heart of all occupational health and industrial hygiene programs involving a continuous process of information gathering. The use of a systematic method to characterize workplace exposures to chemical, physical and biological risks is a fundamental part of this process. This study aims to carry out a preliminary evaluation in a radioactive facility, identifying potential exposures and consequently the existing occupational hazards (risk/agent) in the workplace which the employee is subject. The study is based on proposal to carry out a basic characterization of the facility, which could be the first step in the investigation of occupational exposure. For this study was essential to know the workplace, potential risks and agents; workforce profile including assignment of tasks, sources of exposure processes, and control measures. The main tool used in this study was based on references, records, standards, procedures, interviews with the workers and with management. Since the basic characterization of the facility has been carried out, consequently the potential exposure to the agents of risks to workers has been identified. The study provided an overview of the perception of risk founded at facility studied. It is expected to contribute with the occupational health program resources for welfare of the worker. (author)

  8. Facility for the evaluation of space communications and related systems

    Science.gov (United States)

    Kerczewski, Robert J.; Svoboda, James S.; Kachmar, Brian A.

    1995-01-01

    NASA Lewis Research Center's Communications Projects Branch has developed a facility for the evaluation of space communications systems and related types of systems, called the Advanced Space Communications (ASC) Laboratory. The ASC Lab includes instrumentation, testbed hardware, and experiment control and monitor software for the evaluation of components, subsystems, systems, and networks. The ASC lab has capabilities to perform radiofrequency (RF), microwave, and millimeter-wave characterizations as well as measurements using low, medium, or high data rate digital signals. In addition to laboratory measurements, the ASC Lab also includes integrated satellite ground terminals allowing experimentation and measurements accessing operational satellites through real space links.

  9. A heuristic approach to handle capacitated facility location problem evaluated using clustering internal evaluation

    Science.gov (United States)

    Sutanto, G. R.; Kim, S.; Kim, D.; Sutanto, H.

    2018-03-01

    One of the problems in dealing with capacitated facility location problem (CFLP) is occurred because of the difference between the capacity numbers of facilities and the number of customers that needs to be served. A facility with small capacity may result in uncovered customers. These customers need to be re-allocated to another facility that still has available capacity. Therefore, an approach is proposed to handle CFLP by using k-means clustering algorithm to handle customers’ allocation. And then, if customers’ re-allocation is needed, is decided by the overall average distance between customers and the facilities. This new approach is benchmarked to the existing approach by Liao and Guo which also use k-means clustering algorithm as a base idea to decide the facilities location and customers’ allocation. Both of these approaches are benchmarked by using three clustering evaluation methods with connectedness, compactness, and separations factors.

  10. Design and evaluation of physical protection systems of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    An, Jin Soo; Lee, Hyun Chul; Hwang, In Koo; Kwack, Eun Ho; Choi, Yung Myung

    2001-06-01

    Nuclear material and safety equipment of nuclear facilities are required to be protected against any kind of theft or sabotage. Physical protection is one of the measures to prevent such illegally potential threats for public security. It should cover all the cases of use, storage, and transportation of nuclear material. A physical protection system of a facility consists of exterior intrusion sensors, interior intrusion sensors, an alarm assessment and communication system, entry control systems, access delay equipment, etc. The design of an effective physical protection system requires a comprehensive approach in which the designers define the objective of the system, establish an initial design, and evaluate the proposed design. The evaluation results are used to determine whether or not the initial design should be modified and improved. Some modelling techniques are commonly used to analyse and evaluate the performance of a physical protection system. Korea Atomic Energy Research Institute(KAERI) has developed a prototype of software as a part of a full computer model for effectiveness evaluation for physical protection systems. The input data elements for the prototype, contain the type of adversary, tactics, protection equipment, and the attributes of each protection component. This report contains the functional and structural requirements defined in the development of the evaluation computer model.

  11. Classification of Reactor Facility Operational State Using SPRT Methods with Radiation Sensor Networks

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Aviles, Camila A. [ORNL; Rao, Nageswara S. [ORNL

    2018-01-01

    We consider the problem of inferring the operational state of a reactor facility by using measurements from a radiation sensor network, which is deployed around the facility’s ventilation stack. The radiation emissions from the stack decay with distance, and the corresponding measurements are inherently random with parameters determined by radiation intensity levels at the sensor locations. We fuse measurements from network sensors to estimate the intensity at the stack, and use this estimate in a one-sided Sequential Probability Ratio Test (SPRT) to infer the on/off state of the reactor facility. We demonstrate the superior performance of this method over conventional majority vote fusers and individual sensors using (i) test measurements from a network of NaI sensors, and (ii) emulated measurements using radioactive effluents collected at a reactor facility stack. We analytically quantify the performance improvements of individual sensors and their networks with adaptive thresholds over those with fixed ones, by using the packing number of the radiation intensity space.

  12. Weightless Environment Training Facility (WETF) materials coating evaluation, volume 1

    Science.gov (United States)

    1995-01-01

    The Weightless Environment Training Facility Material Coating Evaluation project has included preparing, coating, testing, and evaluating 800 test panels of three differing substrates. Ten selected coating systems were evaluated in six separate exposure environments and subject to three tests for physical properties. Substrate materials were identified, the manner of surface preparation described, and exposure environments defined. Exposure environments included immersion exposure, cyclic exposure, and field exposure. Cyclic exposures, specifically QUV-Weatherometer and the KTA Envirotest were found to be the most agressive of the environments included in the study when all three evaluation criteria are considered. This was found to result primarily from chalking of the coatings under ultraviolet (UV) light exposure. Volumes 2 and 3 hold the 5 appendices to this report.

  13. A bicycle safety index for evaluating urban street facilities.

    Science.gov (United States)

    Asadi-Shekari, Zohreh; Moeinaddini, Mehdi; Zaly Shah, Muhammad

    2015-01-01

    The objectives of this research are to conceptualize the Bicycle Safety Index (BSI) that considers all parts of the street and to propose a universal guideline with microscale details. A point system method comparing existing safety facilities to a defined standard is proposed to estimate the BSI. Two streets in Singapore and Malaysia are chosen to examine this model. The majority of previous measurements to evaluate street conditions for cyclists usually cannot cover all parts of streets, including segments and intersections. Previous models also did not consider all safety indicators and cycling facilities at a microlevel in particular. This study introduces a new concept of a practical BSI to complete previous studies using its practical, easy-to-follow, point system-based outputs. This practical model can be used in different urban settings to estimate the level of safety for cycling and suggest some improvements based on the standards.

  14. Practical evaluations of low-level waste disposal facilities

    International Nuclear Information System (INIS)

    Rogers, V.C.

    1989-01-01

    In general, there have been about four main tools that have been used to assist in selecting a disposal technology and in evaluating that technology: Legislative direction; Operator selection; Multiattribute utility estimation; and Risk assessment and cost benefit evaluation. The first technique, legislative direction, is an important factor in determining the range of disposal technologies that may be considered. Some host state entities have chosen not to participate in the disposal technology selection, but will let the facility operator propose and defend his preferred facility concept in the license application. Multiattribute utility estimation is a widely used tool for evaluating technologies, particularly in the preliminary stages of selecting a disposal technology when significant technical and institutional information is missing. Many factors, including a range of technical, safety, environmental, societal, political, and economic concerns must be considered in the selection process. Many of these are hard to quantify and not all are of equal importance. Multiattrubute utility estimation allows for these factors to be considered in selecting a technology with incomplete information. This chapter provides description of two analysis techniques: multiattribute utility estimation and cost benefit evaluation. Both can be used to help profile disposal alternatives in relation to specific factors or criteria

  15. Planning Tool for Strategic Evaluation of Facility Plans - 13570

    Energy Technology Data Exchange (ETDEWEB)

    Magoulas, Virginia; Cercy, Michael [Savannah River National Laboratory, Savannah River Site, Aiken, SC 29808 (United States); Hall, Irin [Newport News Shipbuilding, 4101 Washington Ave., Newport News, VA 23607 (United States)

    2013-07-01

    Savannah River National Laboratory (SRNL) has developed a strategic planning tool for the evaluation of the utilization of its unique resources for processing and research and development of nuclear materials. The Planning Tool is a strategic level tool for assessing multiple missions that could be conducted utilizing the SRNL facilities and showcasing the plan. Traditional approaches using standard scheduling tools and laying out a strategy on paper tended to be labor intensive and offered either a limited or cluttered view for visualizing and communicating results. A tool that can assess the process throughput, duration, and utilization of the facility was needed. SRNL teamed with Newport News Shipbuilding (NNS), a division of Huntington Ingalls Industries, to create the next generation Planning Tool. The goal of this collaboration was to create a simulation based tool that allows for quick evaluation of strategies with respect to new or changing missions, and clearly communicates results to the decision makers. This tool has been built upon a mature modeling and simulation software previously developed by NNS. The Planning Tool provides a forum for capturing dependencies, constraints, activity flows, and variable factors. It is also a platform for quickly evaluating multiple mission scenarios, dynamically adding/updating scenarios, generating multiple views for evaluating/communicating results, and understanding where there are areas of risks and opportunities with respect to capacity. The Planning Tool that has been developed is useful in that it presents a clear visual plan for the missions at the Savannah River Site (SRS). It not only assists in communicating the plans to SRS corporate management, but also allows the area stakeholders a visual look at the future plans for SRS. The design of this tool makes it easily deployable to other facility and mission planning endeavors. (authors)

  16. Planning Tool for Strategic Evaluation of Facility Plans - 13570

    International Nuclear Information System (INIS)

    Magoulas, Virginia; Cercy, Michael; Hall, Irin

    2013-01-01

    Savannah River National Laboratory (SRNL) has developed a strategic planning tool for the evaluation of the utilization of its unique resources for processing and research and development of nuclear materials. The Planning Tool is a strategic level tool for assessing multiple missions that could be conducted utilizing the SRNL facilities and showcasing the plan. Traditional approaches using standard scheduling tools and laying out a strategy on paper tended to be labor intensive and offered either a limited or cluttered view for visualizing and communicating results. A tool that can assess the process throughput, duration, and utilization of the facility was needed. SRNL teamed with Newport News Shipbuilding (NNS), a division of Huntington Ingalls Industries, to create the next generation Planning Tool. The goal of this collaboration was to create a simulation based tool that allows for quick evaluation of strategies with respect to new or changing missions, and clearly communicates results to the decision makers. This tool has been built upon a mature modeling and simulation software previously developed by NNS. The Planning Tool provides a forum for capturing dependencies, constraints, activity flows, and variable factors. It is also a platform for quickly evaluating multiple mission scenarios, dynamically adding/updating scenarios, generating multiple views for evaluating/communicating results, and understanding where there are areas of risks and opportunities with respect to capacity. The Planning Tool that has been developed is useful in that it presents a clear visual plan for the missions at the Savannah River Site (SRS). It not only assists in communicating the plans to SRS corporate management, but also allows the area stakeholders a visual look at the future plans for SRS. The design of this tool makes it easily deployable to other facility and mission planning endeavors. (authors)

  17. A tool for urban soundscape evaluation applying Support Vector Machines for developing a soundscape classification model.

    Science.gov (United States)

    Torija, Antonio J; Ruiz, Diego P; Ramos-Ridao, Angel F

    2014-06-01

    To ensure appropriate soundscape management in urban environments, the urban-planning authorities need a range of tools that enable such a task to be performed. An essential step during the management of urban areas from a sound standpoint should be the evaluation of the soundscape in such an area. In this sense, it has been widely acknowledged that a subjective and acoustical categorization of a soundscape is the first step to evaluate it, providing a basis for designing or adapting it to match people's expectations as well. In this sense, this work proposes a model for automatic classification of urban soundscapes. This model is intended for the automatic classification of urban soundscapes based on underlying acoustical and perceptual criteria. Thus, this classification model is proposed to be used as a tool for a comprehensive urban soundscape evaluation. Because of the great complexity associated with the problem, two machine learning techniques, Support Vector Machines (SVM) and Support Vector Machines trained with Sequential Minimal Optimization (SMO), are implemented in developing model classification. The results indicate that the SMO model outperforms the SVM model in the specific task of soundscape classification. With the implementation of the SMO algorithm, the classification model achieves an outstanding performance (91.3% of instances correctly classified). © 2013 Elsevier B.V. All rights reserved.

  18. DETERMINATION OF IMPORTANCE EVALUATION FOR THE SUBSURFACE EXPLORATORY STUDIES FACILITY

    International Nuclear Information System (INIS)

    Clark, W.J.

    1999-01-01

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), the Enhanced Characterization of the Repository Block (ECRB) East-West Cross Drift Starter Tunnel (to approximate ECRB Station 0+26 m), and ancillary test and operation support areas in the TS Loop. This evaluation applies to the construction, operation, and maintenance of these excavations. A more detailed description of these items is provided in Section 6.0. Testing activities are not evaluated in this DIE. Certain construction activities with respect to testing activities are evaluated; but the testing activities themselves are not evaluated. The DIE for ESF Subsurface Testing Activities (BAJ3000000-01717-2200-000111) (CRWMS M and O 1998a) evaluates Subsurface ESF Testing activities. The construction, operation, and maintenance of the TS Loop niches and alcove slot cuts is evaluated herein and is also discussed in CRWMS M and O 1998a. The construction, operation, and maintenance of the Busted Butte subsurface test area in support of the Unsaturated Zone (UZ) Transport Test is evaluated in CRWMS M and O 1998a. Potential test-to-test interference and the waste isolation impacts of testing activities are evaluated in the ESF Subsurface Testing Activities DIE and other applicable evaluation(s) for the Job Package (JP), Test Planning Package (TPP), and/or Field Work Package (FWP). The objectives of this DIE are to determine whether the Subsurface ESF TS Loop and associated excavations, including activities associated with their construction and operation, potentially impact site characterization testing or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified. The validity and veracity of the individual tests, including data collection, are the

  19. DETERMINATION OF IMPORTANCE EVALUATION FOR THE SUBSURFACE EXPORATORY STUDIES FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    W.J. Clark

    1999-06-28

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), the Enhanced Characterization of the Repository Block (ECRB) East-West Cross Drift Starter Tunnel (to approximate ECRB Station 0+26 m), and ancillary test and operation support areas in the TS Loop. This evaluation applies to the construction, operation, and maintenance of these excavations. A more detailed description of these items is provided in Section 6.0. Testing activities are not evaluated in this DIE. Certain construction activities with respect to testing activities are evaluated; but the testing activities themselves are not evaluated. The DIE for ESF Subsurface Testing Activities (BAJ3000000-01717-2200-00011 Rev 01) (CRWMS M&O 1998a) evaluates Subsurface ESF Testing activities. The construction, operation, and maintenance of the TS Loop niches and alcove slot cuts is evaluated herein and is also discussed in CRWMS M&O 1998a. The construction, operation, and maintenance of the Busted Butte subsurface test area in support of the Unsaturated Zone (UZ) Transport Test is evaluated in CRWMS M&O 1998a. Potential test-to-test interference and the waste isolation impacts of testing activities are evaluated in the ESF Subsurface Testing Activities DIE and other applicable evaluation(s) for the Job Package (JP), Test Planning Package (TPP), and/or Field Work Package (FWP). The objectives of this DIE are to determine whether the Subsurface ESF TS Loop and associated excavations, including activities associated with their construction and operation, potentially impact site characterization testing or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified. The validity and veracity of the individual tests, including data collection, are the responsibility

  20. Shielding Design and Radiation Shielding Evaluation for LSDS System Facility

    International Nuclear Information System (INIS)

    Kim, Younggook; Kim, Jeongdong; Lee, Yongdeok

    2015-01-01

    As the system characteristics, the target in the spectrometer emits approximately 1012 neutrons/s. To efficiently shield the neutron, the shielding door designs are proposed for the LSDS system through a comparison of the direct shield and maze designs. Hence, to guarantee the radiation safety for the facility, the door design is a compulsory course of the development of the LSDS system. To improve the shielding rates, 250x250 covering structure was added as a subsidiary around the spectrometer. In this study, the evaluations of the suggested shielding designs were conducted using MCNP code. The suggested door design and covering structures can shield the neutron efficiently, thus all evaluations of all conditions are satisfied within the public dose limits. From the Monte Carlo code simulation, Resin(Indoor type) and Tungsten(Outdoor type) were selected as the shielding door materials. From a comparative evaluation of the door thickness, In and Out door thickness was selected 50 cm

  1. Technical evaluation of proposed Ukrainian Central Radioactive Waste Processing Facility

    International Nuclear Information System (INIS)

    Gates, R.; Glukhov, A.; Markowski, F.

    1996-06-01

    This technical report is a comprehensive evaluation of the proposal by the Ukrainian State Committee on Nuclear Power Utilization to create a central facility for radioactive waste (not spent fuel) processing. The central facility is intended to process liquid and solid radioactive wastes generated from all of the Ukrainian nuclear power plants and the waste generated as a result of Chernobyl 1, 2 and 3 decommissioning efforts. In addition, this report provides general information on the quantity and total activity of radioactive waste in the 30-km Zone and the Sarcophagus from the Chernobyl accident. Processing options are described that may ultimately be used in the long-term disposal of selected 30-km Zone and Sarcophagus wastes. A detailed report on the issues concerning the construction of a Ukrainian Central Radioactive Waste Processing Facility (CRWPF) from the Ukrainian Scientific Research and Design institute for Industrial Technology was obtained and incorporated into this report. This report outlines various processing options, their associated costs and construction schedules, which can be applied to solving the operating and decommissioning radioactive waste management problems in Ukraine. The costs and schedules are best estimates based upon the most current US industry practice and vendor information. This report focuses primarily on the handling and processing of what is defined in the US as low-level radioactive wastes

  2. Development of an In-Situ Radiological Classification Technique for Material from CERN's Accelerator Facilities

    CERN Document Server

    AUTHOR|(CDS)2081300; Froeschl, Robert; Forkel-Wirth, Doris

    CERN, the European Organization for Nuclear Research, operates high energy accelerators for particle physics research. Because of beam losses and subsequent particle interactions, radioactivity can be induced in certain accelerator components. Material and waste taken out of the accelerators facilities as a result of maintenance repair and upgrade actions as well as in case of decommissioning needs to be radiologically classied for future handling. Depending on the level of residual activity, some of these components are candidates for clearance from regulatory control in Switzerland. The Swiss radiation protection ordinance sets as criteria for clearance of material and waste from regulatory control the compliance with radionuclide specic limits for surface contamination and for specic activity as well as an ambient dose equivalent rate criterion. For objects with a mass below 1 kg a radionuclide specic clearance limit for total activity has to be respected. This work is focused on the specic activity criter...

  3. Evaluating Intervention Effects in a Diagnostic Classification Model Framework

    Science.gov (United States)

    Madison, Matthew J.; Bradshaw, Laine

    2018-01-01

    The evaluation of intervention effects is an important objective of educational research. One way to evaluate the effectiveness of an intervention is to conduct an experiment that assigns individuals to control and treatment groups. In the context of pretest/posttest designed studies, this is referred to as a control-group pretest/posttest design.…

  4. International symposium on seismic evaluation of existing nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Orbovic, N.; Bouchon, M. [Institut de Radioprotection et de Surete Nucleaire, IRSN, 92 - Fontenay aux Roses (France); Vendel, J.; Gelain, T. [IRSN/DPEA/SERAC, 91 - Gif sur Yvette (France)

    2003-10-01

    Below are summarized the works of Mrs N. Orbovic and M. Bouchon; B. Stojadinovic, N. Orbovic, M.Bouchon and J.T. Wiley; M. Bouchon, N. Orbovic and B. Foure; T. Gelain, F. Gensdarmes, R. Sestier-Carlin, J. Vendel and M. Bouchon dealing respectively with: 1) seismic assessment of existing nuclear facility: a case study position of the IRSN 2) static and dynamic evaluation of an existing nuclear facility reinforced concrete frame structure 3) experimental study of cracking of low-rise reinforced concrete shear walls 4) aeraulics study of crack networks on low-rise reinforced concrete walls subject to static cycling loading. The summaries are followed: 1) The Institute for Radioprotection and Nuclear Safety (IRSN) has the task of evaluating the seismic safety of existing building inventory in French nuclear facilities. Some of the existing structures are reinforced concrete frame buildings with masonry or reinforced concrete in-fill walls built during the 1960's, 70's and 80's following different building codes and seismic input data applicable at the time of construction. The studied building is a laboratory that was built in 1962. The building is composed of three different and independent blocks. The structure is a reinforced concrete frame with masonry in-fills and few stiff concrete elements. Moreover, the building contains an independent massive concrete cell. Structurally, the building has a number of irregularities. From the detailing standpoint, well known deficiencies of low-ductile reinforced concrete structures are evident especially, a lack of transverse reinforcement in the structural joints of the frame. A number of sensitivity studies were conducted using 2D and 3D linear models to evaluate seismic demand. Ambient vibration and regional earthquake records were used to check the soil nature and the existence or not of a possible site effect around the installation as well as to characterize the dynamic behavior of the building. 3D models

  5. International symposium on seismic evaluation of existing nuclear facilities

    International Nuclear Information System (INIS)

    Orbovic, N.; Bouchon, M.; Vendel, J.; Gelain, T.

    2003-10-01

    Below are summarized the works of Mrs N. Orbovic and M. Bouchon; B. Stojadinovic, N. Orbovic, M.Bouchon and J.T. Wiley; M. Bouchon, N. Orbovic and B. Foure; T. Gelain, F. Gensdarmes, R. Sestier-Carlin, J. Vendel and M. Bouchon dealing respectively with: 1) seismic assessment of existing nuclear facility: a case study position of the IRSN 2) static and dynamic evaluation of an existing nuclear facility reinforced concrete frame structure 3) experimental study of cracking of low-rise reinforced concrete shear walls 4) aeraulics study of crack networks on low-rise reinforced concrete walls subject to static cycling loading. The summaries are followed: 1) The Institute for Radioprotection and Nuclear Safety (IRSN) has the task of evaluating the seismic safety of existing building inventory in French nuclear facilities. Some of the existing structures are reinforced concrete frame buildings with masonry or reinforced concrete in-fill walls built during the 1960's, 70's and 80's following different building codes and seismic input data applicable at the time of construction. The studied building is a laboratory that was built in 1962. The building is composed of three different and independent blocks. The structure is a reinforced concrete frame with masonry in-fills and few stiff concrete elements. Moreover, the building contains an independent massive concrete cell. Structurally, the building has a number of irregularities. From the detailing standpoint, well known deficiencies of low-ductile reinforced concrete structures are evident especially, a lack of transverse reinforcement in the structural joints of the frame. A number of sensitivity studies were conducted using 2D and 3D linear models to evaluate seismic demand. Ambient vibration and regional earthquake records were used to check the soil nature and the existence or not of a possible site effect around the installation as well as to characterize the dynamic behavior of the building. 3D models revealed a

  6. Evaluation of the ORNL area for future waste burial facilities

    International Nuclear Information System (INIS)

    Lomenick, T.F.; Byerly, D.W.; Gonzales, S.

    1983-10-01

    Additional waste-burial facilities will be needed at ORNL within this decade. In order to find environmentally acceptable sites, the ORNL area must be systematically evaluated. This document represents the first step in that selection process. Geologic and hydrologic data from the literature and minor field investigations are used to identify more favorable sites for Solid Waste Storage Area (SWSA) 7. Also underway at this time is a companion study to locate a Central Waste Storage Area which could be used in the future to accommodate wastes generated by the X-10, Y-12, and K-25 facilities. From the several watershed options available, the Whiteoak Creek drainage basin is selected as the most promising hydrologic regime. This area contains all past and present waste-disposal facilities and is thus already well monitored. The seven bedrock units within the ORNL area are evaluated as potential burial media. Shales of the Conasauga Group, which are currently used for waste burial in the Whiteoak Creek drainage basin, and the Knox Group are considered the leading candidates. Although the residuum derived from and overlying the Knox dolomite has many favorable characteristics and may be regarded as having a high potential for burial of low-level wastes, at the present it is unproven. Therefore, the Conasauga shales are considered a preferable option for SWSA 7 within the ORNL area. Since the Conasauga interval is currently used for waste burial, it is better understood. One tract in Melton Valley that is underlain by Conasauga shales is nominated for detailed site-characterization studies, and several other tracts are recommended for future exploratory drilling. Exploration is also suggested for a tract in the upper Whiteoak Creek basin where Knox residuum is the shallow subsurface material

  7. DETERMINATION OF IMPORTANCE EVALUATION FOR THE SURFACE EXPLORATORY STUDIES FACILITY

    International Nuclear Information System (INIS)

    C.J. Byrne

    2000-01-01

    This DIE applies to the surface facilities component of the Yucca Mountain Site Characterization Project (W) ESF. The ESF complex-including surface and subsurface accommodations--encompasses an area that is approximately six miles wide and nine miles long (approximately 30,000 acres total) (United States Department of Energy [DOE] 1997, p. 9.04). It is located on federally withdrawn lands, near the southwest border of the Nevada Test Site (NTS) in southern Nevada (DOE 1997, p. 9.04). Site characterization activities are conducted within the subsurface ESF to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. Most ESF surface facilities are located within the Conceptual Controlled Area Boundary (CCAB) (DOE 1997, p. 9.04), with the exception of the southeastern most portions of the H-Road and the Water Supply System. Various SBT activities are also conducted throughout the Yucca Mountain region as a part of the overall site-characterization effort. In general, the DIE for SBT Activities (Civilian Radioactive Waste Management System [CRWMS] Management and Operating Contractor [M andO] 1998a) evaluates activities associated with SBT. Potential test-to-test interference and waste isolation impacts associated with SBT activities are also evaluated in CRWMS M andO (1998a)

  8. DETERMINATION OF IMPORTANCE EVALUATION FOR THE SURFACE EXPLORATORY STUDIES FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    C.J. Byrne

    2000-07-25

    This DIE applies to the surface facilities component of the Yucca Mountain Site Characterization Project (W) ESF. The ESF complex-including surface and subsurface accommodations--encompasses an area that is approximately six miles wide and nine miles long (approximately 30,000 acres total) (United States Department of Energy [DOE] 1997, p. 9.04). It is located on federally withdrawn lands, near the southwest border of the Nevada Test Site (NTS) in southern Nevada (DOE 1997, p. 9.04). Site characterization activities are conducted within the subsurface ESF to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. Most ESF surface facilities are located within the Conceptual Controlled Area Boundary (CCAB) (DOE 1997, p. 9.04), with the exception of the southeastern most portions of the H-Road and the Water Supply System. Various SBT activities are also conducted throughout the Yucca Mountain region as a part of the overall site-characterization effort. In general, the DIE for SBT Activities (Civilian Radioactive Waste Management System [CRWMS] Management and Operating Contractor [M&O] 1998a) evaluates activities associated with SBT. Potential test-to-test interference and waste isolation impacts associated with SBT activities are also evaluated in CRWMS M&O (1998a).

  9. The Relationship of Microorganism Classification by US Government Guidelines to the Design pof Laboratory Facilities

    International Nuclear Information System (INIS)

    Robinson, D.

    2007-01-01

    When the first edition of the Biosafety in Microbiological and Biomedical Laboratories, (BMBL) series was published approximately 40 years ago its purpose was to provide a code of practice, guidelines and standards for the prevention of laboratory acquired infections to the laboratorian working in an infectious disease laboratory. The BMBL is based on the microorganism being worked on and is a set of recommendations, which are advisory. While this is true, many agencies in the US government have incorporated all or parts of the BMBL in their regulations. This has led to the BMBL being accepted as the de facto US standard for the design and operation of infectious disease laboratories. The concept of biosecurity has evolved as a result of concerns related o access to microorganisms by terrorists following the anthrax letters of October 2001. While related to biosafety the specific requirements vary from those related to biosafety and are based on laws passed by the US Congress. The Select Agent Program of the US Centres for Disease Control has been given the responsibility for codifying and enforcing these regulations. Both biosafety and biosecurity need to be considered in the design of a laboratory facility. The occasionally conflicting regulatory requirements can be best resolved by conducting a Risk Assessment, which takes into account the microorganisms and the manipulations planned for the laboratory. This is an essential step for both laboratory design and subsequent laboratory operation. (author)

  10. Characterization and classification of radioactive waste from the accelerator facilities at PSI

    International Nuclear Information System (INIS)

    Teichmann, S.; Wohlmuther, M.; Zuellig, J.

    2005-01-01

    At the accelerator facilities of PSI, with a 1 MW ring cyclotron that accelerates protons to 590 MeV as essential part, various components are removed regularly that need to be disposed as radioactive waste. As principal part of the characterisation of this waste, the nuclide inventory is determined using a specially devised calculation method. For this calculation, nuclide production cross sections from a specifically developed data bank are folded with neutron spectra typical for the particular radiation environment, and normalized with a measured dose rate. After separating materials needing special treatment, the waste components (mainly steel, copper and concrete items) are placed in a concrete container and temporarily stored. For the solidification with cement (final conditioning), a specification of the waste container has to be submitted on the basis of which the responsible institutions Nagra and HSK issue a certificate concerning the suitability for a final repository and a license for final conditioning. The relevant data of the waste containers are documented in container data sheets and in an electronic data bank. Some properties of filled waste containers are described. (orig.)

  11. Performance Evaluation Facility for Fire Fighting Thermal Imager

    International Nuclear Information System (INIS)

    Kim, Sung Chan; Amon, Francine; Hamins, Anthony

    2007-01-01

    The present study investigates the characteristics of obscuring media inside an optical smoke cell, which is a bench-scale testing facility for the evaluation of thermal imaging cameras used by fire fighters. Light extinction coefficient and visibility through the smoke cell is characterized by the measured laser transmittance. The laser transmittance along the axial direction of the smoke cell is relatively uniform at upper and lower part for various air/fuel volume flow rate. Contrast level based image quality of visible CCD camera through the smoke cell is compared with that of thermal imaging camera. The optical smoke cell can be used as well-controlled and effective laboratory-scale test apparatus to evaluate the performance of thermal imaging camera for fire fighting application

  12. Analysis of genetic divergence for classification and evaluation of 37 ...

    African Journals Online (AJOL)

    ajl yemi

    2011-12-19

    Dec 19, 2011 ... evaluation of 37 productive performances in all 54 oval cocoon strains of Iran ... strains, indicating that they might be suitable for future crossings, maintenance of ... Japan, Korea and India, the total number of mulberry and.

  13. Analysis of genetic divergence for classification and evaluation of 37 ...

    African Journals Online (AJOL)

    Studied strains are ranked based on the average of evaluation index method and ... of silkworm B. mori showed different performances based on productive traits. ... for future crossings, maintenance of parental strains and hybridizations with ...

  14. Study on uncertainty evaluation system for the safety evaluation of interim spent fuel storage facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Hyeon; Shin, Myeong Won; Rhy, Seok Jin; Cho, Dong Keon; Park, Dong Hwan [Kyunghee Univ., Seoul (Korea, Republic of); Cheong, Beom Jin [Minstry of Science and Technology, Gwacheon (Korea, Republic of)

    1998-03-15

    The main objective os to develop a technical standards for the facility operation of the interm, spent fuel storage facility and to develop a draft for the technical criteria to be legislated. The another objective os to define a uncertainty evaluation system for burn up credit application in criticality analysis and to investigate an applicability of this topic for future regulatory activity. Investigate a status of art for the operational criteria of spent fuel interm wet storage. Collect relevant laws, decree, notices and standards related to the operation of storage facility and study on the legislation system. Develop a draft of technical standards and criteria to be legislated. Define an evaluation system for the uncertainty analysis and study on the status of art in the field of criticality safety analysis. Develop an uncertainty evaluation system in criticality analysis with burnup credit and investigate an applicability as well as its benefits of this policy.

  15. Performance Evaluation of Frequency Transform Based Block Classification of Compound Image Segmentation Techniques

    Science.gov (United States)

    Selwyn, Ebenezer Juliet; Florinabel, D. Jemi

    2018-04-01

    Compound image segmentation plays a vital role in the compression of computer screen images. Computer screen images are images which are mixed with textual, graphical, or pictorial contents. In this paper, we present a comparison of two transform based block classification of compound images based on metrics like speed of classification, precision and recall rate. Block based classification approaches normally divide the compound images into fixed size blocks of non-overlapping in nature. Then frequency transform like Discrete Cosine Transform (DCT) and Discrete Wavelet Transform (DWT) are applied over each block. Mean and standard deviation are computed for each 8 × 8 block and are used as features set to classify the compound images into text/graphics and picture/background block. The classification accuracy of block classification based segmentation techniques are measured by evaluation metrics like precision and recall rate. Compound images of smooth background and complex background images containing text of varying size, colour and orientation are considered for testing. Experimental evidence shows that the DWT based segmentation provides significant improvement in recall rate and precision rate approximately 2.3% than DCT based segmentation with an increase in block classification time for both smooth and complex background images.

  16. Functional requirements for an Exercise Evaluation and Simulation Facility

    International Nuclear Information System (INIS)

    1983-04-01

    The Exercise Evaluation and Simulation Facility (EESF) is a computer-based resource that will improve FEMA's capabilities for evaluating radiological emergency plans and preparedness around commercial nuclear sites. The EESF is being designed from the perspective of the organizations involved (i.e., FEMA Regional and National, and state and local response teams) and takes into account the evolution of radiological and other emergency preparedness activities. Like radiological emergency planning, EESF will evolve to suit FEMA (National and Regional) needs and interests and will be increasingly useful as a resource for radiological emergency planning and evaluation. Table ES-1 briefly describes seven functions for which EESF is currently being designed. They are listed in the approximate order in which they will be designed, developed, and implemented. The only exception is the data base function, which will be developed parallel with the other six functions and enhanced to support these functions, as well as be a source of information on sites, plans, exercises, and evaluations

  17. Risk management study for the retired Hanford Site facilities: Qualitative risk evaluation for the retired Hanford Site facilities

    International Nuclear Information System (INIS)

    Coles, G.A.; Shultz, M.V.; Taylor, W.E.

    1993-09-01

    This document provides a risk evaluation of the 100 and 200 Area retired, surplus facilities on the Hanford Site. Also included are the related data that were compiled by the risk evaluation team during investigations performed on the facilities. Results are the product of a major effort performed in fiscal year 1993 to produce qualitative information that characterizes certain risks associated with these facilities. The retired facilities investigated for this evaluation are located in the 100 and 200 Areas of the 1,450-km 2 (570-mi 2 ) Hanford Site. The Hanford Site is a semiarid tract of land in southeastern Washington State. The nearest population center is Richland, Washington, (population 32,000) 30-km (20 mi) southeast of the 200 Area. During walkdown investigations of these facilities, data on real and potential hazards that threatened human health or safety or created potential environmental release issues were identified by the risk evaluation team. Using these findings, the team categorized the identified hazards by facility and evaluated the risk associated with each hazard. The factors contributing to each risk, and the consequence and likelihood of harm associated with each hazard also are included in this evaluation

  18. Risk management study for the retired Hanford Site facilities: Qualitative risk evaluation for the retired Hanford Site facilities. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Coles, G.A.; Shultz, M.V.; Taylor, W.E.

    1993-09-01

    This document provides a risk evaluation of the 100 and 200 Area retired, surplus facilities on the Hanford Site. Also included are the related data that were compiled by the risk evaluation team during investigations performed on the facilities. Results are the product of a major effort performed in fiscal year 1993 to produce qualitative information that characterizes certain risks associated with these facilities. The retired facilities investigated for this evaluation are located in the 100 and 200 Areas of the 1,450-km{sup 2} (570-mi{sup 2}) Hanford Site. The Hanford Site is a semiarid tract of land in southeastern Washington State. The nearest population center is Richland, Washington, (population 32,000) 30-km (20 mi) southeast of the 200 Area. During walkdown investigations of these facilities, data on real and potential hazards that threatened human health or safety or created potential environmental release issues were identified by the risk evaluation team. Using these findings, the team categorized the identified hazards by facility and evaluated the risk associated with each hazard. The factors contributing to each risk, and the consequence and likelihood of harm associated with each hazard also are included in this evaluation.

  19. Evaluation of the improvement suggestion system in a nuclear facility

    International Nuclear Information System (INIS)

    Carnaval, Joao Paulo Rodrigues; Moraes, Geice Almeida

    2017-01-01

    This work evaluated methods for processing improvement suggestions of a nuclear factory, with the intention to verify those which best fits to the company purposes. Two methods for processing improvement suggestions were applied in the studied organization. The first one was guided to the processing suggestions by specific independent sectors of the company and the second one was conducted to the processing of suggestions by a multidisciplinary team. It has been concluded that a multidisciplinary team focused on research and development would be the best option to the implementation of improvement suggestions and technological innovation on this facility, instead of multi sector processing which revealed to be excessive bureaucratic before the expected goals. This study can be used by nuclear facilities to optimize an existing system of improvements analysis or even guide them for the implantation of a new one. It is more significant for the companies certified on ISO and OHSAS standards for the quality management, environmental and safety and occupational health systems which requires that the continuous improvement must exist and to be demonstrated. But it is also relevant for nuclear plants aiming to implement an Integrated Management System certified on ISO Standards. (author)

  20. Evaluation of a high-level waste radiological maintenance facility

    International Nuclear Information System (INIS)

    Collins, K.J.

    1998-01-01

    The Savannah River Site''s (SRS) Defense Waste Processing Facility (DWPF) near Aiken, SC is the nation''s first and world''s largest high level waste vitrification facility. DWPF began, operations in March 1996 to process radioactive waste, consisting of a matrixed predominantly 137 Cs precipitate and a predominately 90 Sr and alpha emitting sludge, into boro-silicate glass for long term storage. Presently, DWPF is processing only sludge waste and is preparing to process a combination of sludge and precipitate waste. During precipitate operations, canister dose rates are expected to exceed 10 Sv hr -1 (1000 rem hr -1 ). In sludge-only operations, canister contact gamma dose rates are approximately 15 mSv hr -1 (1500 mrem hr -1 ). Transferable contamination levels have been greater than 10 mSv hr -1 (100 cm 2 ) -1 for beta-gamma emitters and into the millions of Bq (100 cm 2 ) -1 for the alpha emitting radionuclides. This paper presents an evaluation of the radiological maintenance areas and their ability to support radiological work

  1. Evaluation of the improvement suggestion system in a nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Carnaval, Joao Paulo Rodrigues; Moraes, Geice Almeida, E-mail: joaocarnaval@inb.gov.br, E-mail: geice@inb.gov.br [Industrias Nucleares do Brasil S.A (INB), Resende, RJ (Brazil)

    2017-11-01

    This work evaluated methods for processing improvement suggestions of a nuclear factory, with the intention to verify those which best fits to the company purposes. Two methods for processing improvement suggestions were applied in the studied organization. The first one was guided to the processing suggestions by specific independent sectors of the company and the second one was conducted to the processing of suggestions by a multidisciplinary team. It has been concluded that a multidisciplinary team focused on research and development would be the best option to the implementation of improvement suggestions and technological innovation on this facility, instead of multi sector processing which revealed to be excessive bureaucratic before the expected goals. This study can be used by nuclear facilities to optimize an existing system of improvements analysis or even guide them for the implantation of a new one. It is more significant for the companies certified on ISO and OHSAS standards for the quality management, environmental and safety and occupational health systems which requires that the continuous improvement must exist and to be demonstrated. But it is also relevant for nuclear plants aiming to implement an Integrated Management System certified on ISO Standards. (author)

  2. Technical Evaluation Report 5: Classification of DE Delivery Systems

    Directory of Open Access Journals (Sweden)

    Diane Belyk

    2002-01-01

    Full Text Available For their optimal use in distance education (DE, online educational applications need to be integrated within a comprehensive course management system (CMS. Such systems are server-based software that supports the development, delivery, administration, and evaluation of online learning environments. The selection of an appropriate CMS should be considered from the multiple perspectives of the student, the course developer, the course instructor/ tutor, the technical support staff, and the DE institution’s administration. The current evaluation of CMS packages was conducted by a team of individuals with experience and contacts in relation to each of these DE user types. The report compares a series of CMS packages in terms of their range of features, and in relation to their satisfaction of international online education standards.

  3. Quality Evaluation of Land-Cover Classification Using Convolutional Neural Network

    Science.gov (United States)

    Dang, Y.; Zhang, J.; Zhao, Y.; Luo, F.; Ma, W.; Yu, F.

    2018-04-01

    Land-cover classification is one of the most important products of earth observation, which focuses mainly on profiling the physical characters of the land surface with temporal and distribution attributes and contains the information of both natural and man-made coverage elements, such as vegetation, soil, glaciers, rivers, lakes, marsh wetlands and various man-made structures. In recent years, the amount of high-resolution remote sensing data has increased sharply. Accordingly, the volume of land-cover classification products increases, as well as the need to evaluate such frequently updated products that is a big challenge. Conventionally, the automatic quality evaluation of land-cover classification is made through pixel-based classifying algorithms, which lead to a much trickier task and consequently hard to keep peace with the required updating frequency. In this paper, we propose a novel quality evaluation approach for evaluating the land-cover classification by a scene classification method Convolutional Neural Network (CNN) model. By learning from remote sensing data, those randomly generated kernels that serve as filter matrixes evolved to some operators that has similar functions to man-crafted operators, like Sobel operator or Canny operator, and there are other kernels learned by the CNN model that are much more complex and can't be understood as existing filters. The method using CNN approach as the core algorithm serves quality-evaluation tasks well since it calculates a bunch of outputs which directly represent the image's membership grade to certain classes. An automatic quality evaluation approach for the land-cover DLG-DOM coupling data (DLG for Digital Line Graphic, DOM for Digital Orthophoto Map) will be introduced in this paper. The CNN model as an robustness method for image evaluation, then brought out the idea of an automatic quality evaluation approach for land-cover classification. Based on this experiment, new ideas of quality evaluation

  4. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Cong, Rui, E-mail: congrui2684@163.com; Li, Jing, E-mail: lijing@sj-hospital.org; Guo, Song, E-mail: 21751735@qq.com

    2017-02-15

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  5. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    International Nuclear Information System (INIS)

    Cong, Rui; Li, Jing; Guo, Song

    2017-01-01

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  6. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation.

    Science.gov (United States)

    Cong, Rui; Li, Jing; Guo, Song

    2017-02-01

    To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all Pbreast mass diagnoses. Copyright © 2016. Published by Elsevier B.V.

  7. Evaluation of cold testing for Tokai Vitrification Facility

    International Nuclear Information System (INIS)

    Yoshioka, Masahiro; Inada, Eiichi

    1994-01-01

    The cold testing of the Tokai Vitrification Facility (TVF) was completed at the end of March, 1994 through the tests of nearly two years since May in 1992. The cold testing was carried out in order to evaluate the process equipment, product quality control, remote maintenance capability. The test results shown that TVF has enough performance with safety to treat the liquid waste in each process, and to control the product quality. For the remote maintenance of process equipment in the vitrification cell, the remote maintenance capability was confirmed for all remote equipment in the cell. The improvements were taken for some equipment with problem from the point of the operability and maintenance. It was confirmed by these test results that the TVF can go forward to the hot test operation using actual waste. (author)

  8. Evaluation of renewable energy alternatives for highway maintenance facilities.

    Science.gov (United States)

    2013-12-01

    A considerable annual energy budget is used for heating, lighting, cooling and operating ODOT : maintenance facilities. Such facilities contain vehicle repair and garage bays, which are large open : spaces with high heating demand in winter. The main...

  9. Dengue disease severity in Indonesian children: An evaluation of the World Health Organization classification system

    NARCIS (Netherlands)

    T.E. Setiati (Tatty); A.T.A. Mairuhu; P. Koraka (Penelope); M. Supriatna (Mohamad); M.R. Mac Gillavry (Melvin); D.P.M. Brandjes (Dees); A.D.M.E. Osterhaus (Albert); J.W.M. van der Meer (Jos); E.C.M. van Gorp (Eric); A. Soemantri (Augustinus)

    2007-01-01

    textabstractBackground: Dengue disease severity is usually classified using criteria set up by the World Health Organization (WHO). We aimed to assess the diagnostic accuracy of the WHO classification system and modifications to this system, and evaluated their potential practical usefulness.

  10. An Ontology to Support the Classification of Learning Material in an Organizational Learning Environment: An Evaluation

    Science.gov (United States)

    Valaski, Joselaine; Reinehr, Sheila; Malucelli, Andreia

    2017-01-01

    Purpose: The purpose of this research was to evaluate whether ontology integrated in an organizational learning environment may support the automatic learning material classification in a specific knowledge area. Design/methodology/approach: An ontology for recommending learning material was integrated in the organizational learning environment…

  11. Classification and moral evaluation of uncertainties in engineering modeling.

    Science.gov (United States)

    Murphy, Colleen; Gardoni, Paolo; Harris, Charles E

    2011-09-01

    Engineers must deal with risks and uncertainties as a part of their professional work and, in particular, uncertainties are inherent to engineering models. Models play a central role in engineering. Models often represent an abstract and idealized version of the mathematical properties of a target. Using models, engineers can investigate and acquire understanding of how an object or phenomenon will perform under specified conditions. This paper defines the different stages of the modeling process in engineering, classifies the various sources of uncertainty that arise in each stage, and discusses the categories into which these uncertainties fall. The paper then considers the way uncertainty and modeling are approached in science and the criteria for evaluating scientific hypotheses, in order to highlight the very different criteria appropriate for the development of models and the treatment of the inherent uncertainties in engineering. Finally, the paper puts forward nine guidelines for the treatment of uncertainty in engineering modeling.

  12. Evaluation of the histopathological classifications of American cutaneous and mucocutaneous leishmaniasis

    Directory of Open Access Journals (Sweden)

    A. L. Bittencourt

    1991-03-01

    Full Text Available In order to evaluate the reliability of histopathological classifications of cutaneous and mucocutaneous leishmaniasis the authors compared the histopathological patterns of two biopsies taken simultaneously from the same patient, and classified the material according to Ridley et al. (1980, to Magalhães et al. (1986a, and to a more simplified classification with only three patterns. District histopathological aspects, were observed in different lesions or even in the same lesion. The authors concluded that histopathological patterns do not represent a stage of tegumentary leishmaniasis, thus they can not be correlated with prognosis and therapeutical response as suggested in the literature.

  13. EVALUATING THE POTENTIAL OF SATELLITE HYPERSPECTRAL RESURS-P DATA FOR FOREST SPECIES CLASSIFICATION

    Directory of Open Access Journals (Sweden)

    O. Brovkina

    2016-06-01

    Full Text Available Satellite-based hyperspectral sensors provide spectroscopic information in relatively narrow contiguous spectral bands over a large area which can be useful in forestry applications. This study evaluates the potential of satellite hyperspectral Resurs-P data for forest species mapping. Firstly, a comparative study between top of canopy reflectance obtained from the Resurs-P, from the airborne hyperspectral scanner CASI and from field measurement (FieldSpec ASD 4 on selected vegetation cover types is conducted. Secondly, Resurs-P data is tested in classification and verification of different forest species compartments. The results demonstrate that satellite hyperspectral Resurs-P sensor can produce useful informational and show good performance for forest species classification comparable both with forestry map and classification from airborne CASI data, but also indicate that developments in pre-processing steps are still required to improve the mapping level.

  14. Credit Risk Evaluation Using a C-Variable Least Squares Support Vector Classification Model

    Science.gov (United States)

    Yu, Lean; Wang, Shouyang; Lai, K. K.

    Credit risk evaluation is one of the most important issues in financial risk management. In this paper, a C-variable least squares support vector classification (C-VLSSVC) model is proposed for credit risk analysis. The main idea of this model is based on the prior knowledge that different classes may have different importance for modeling and more weights should be given to those classes with more importance. The C-VLSSVC model can be constructed by a simple modification of the regularization parameter in LSSVC, whereby more weights are given to the lease squares classification errors with important classes than the lease squares classification errors with unimportant classes while keeping the regularized terms in its original form. For illustration purpose, a real-world credit dataset is used to test the effectiveness of the C-VLSSVC model.

  15. Evaluation of rock classifications at B. C. Rail tumbler ridge tunnels

    Science.gov (United States)

    Kaiser, Peter K.; Mackay, C.; Gale, A. D.

    1986-10-01

    Construction of four single track railway tunnels through sedimentary rocks in central British Columbia, Canada, provided an excellent opportunity to compare various rock mass classification systems and to evaluate their applicability to the local geology. The tunnels were excavated by conventional drilling and blasting techniques and supported primarily with rock bolts and shotcrete, and with steel sets in some sections. After a brief project description including tunnel construction techniques, local geology and groundwater conditions, the data collection and filed mapping procedure is reviewed. Four rock mass classification systems ( RQD, RSR, RMR, Q) for empirical tunnel design are reviewed and relevant factors for the data interpretation are discussed. In comparing and evaluating the performance of these classification systems three aspects received special attention. The tunnel support predicted by the various systems was compared to the support installed, a unique correlation between the two most useful and most frequently applied classifications, the RMR and Q systems, was established and assessed, and finally, the non-support limit and size effect were evaluated. It is concluded that the Q-system best predicted the required tunnel support and that the RMR was only adequate after adjustment for the influence of opening size. Correction equations for opening size effects are presented for the RMR system. The RSR and RQD systems are not recommended for empirical tunnel design.

  16. Evaluation of nuclear power plant operating procedures classifications and interfaces: Problems and techniques for improvement

    International Nuclear Information System (INIS)

    Barnes, V.E.; Radford, L.R.

    1987-02-01

    This report presents activities and findings of a project designed to evaluate current practices and problems related to procedure classification schemes and procedure interfaces in commercial nuclear power plants. The phrase ''procedure classification scheme'' refers to how plant operating procedures are categorized and indexed (e.g., normal, abnormal, emergency operating procedures). The term ''procedure interface'' refers to how reactor operators are instructed to transition within and between procedures. The project consisted of four key tasks, including (1) a survey of literature regarding problems associated with procedure classifications and interfaces, as well as techniques for overcoming them; (2) interviews with experts in the nuclear industry to discuss the appropriate scope of different classes of operating procedures and techniques for managing interfaces between them; (3) a reanalysis of data gathered about nuclear power plant normal operating and off-normal operating procedures in a related project, ''Program Plan for Assessing and Upgrading Operating Procedures for Nuclear Power Plants''; and (4) solicitation of the comments and expert opinions of a peer review group on the draft project report and on proposed techniques for resolving classification and interface issues. In addition to describing these activities and their results, recommendations for NRC and utility actions to address procedure classification and interface problems are offered

  17. Evaluation of the Waste Isolation Pilot Plant classification of systems, structures and components

    International Nuclear Information System (INIS)

    1985-07-01

    A review of the classification system for systems, structures, and components at the Waste Isolation Pilot Plant (WIPP) was performed using the WIPP Safety Analysis Report (SAR) and Bechtel document D-76-D-03 as primary source documents. The regulations of the US Nuclear Regulatory Commission (NRC) covering ''Disposal of High level Radioactive Wastes in Geologic Repositories,'' 10 CFR 60, and the regulations relevant to nuclear power plant siting and construction (10 CFR 50, 51, 100) were used as standards to evaluate the WIPP design classification system, although it is recognized that the US Department of Energy (DOE) is not required to comply with these NRC regulations in the design and construction of WIPP. The DOE General Design Criteria Manual (DOE Order 6430.1) and the Safety Analysis and Review System for AL Operation document (AL 54f81.1A) were reviewed in part. This report includes a discussion of the historical basis for nuclear power plant requirements, a review of WIPP and nuclear power plant classification bases, and a comparison of the codes and standards applicable to each quality level. Observations made during the review of the WIPP SAR are noted in the text of this reoport. The conclusions reached by this review are: WIPP classification methodology is comparable to corresponding nuclear power procedures. The classification levels assigned to WIPP systems are qualitatively the same as those assigned to nuclear power plant systems

  18. Analysis and Evaluation of IKONOS Image Fusion Algorithm Based on Land Cover Classification

    Institute of Scientific and Technical Information of China (English)

    Xia; JING; Yan; BAO

    2015-01-01

    Different fusion algorithm has its own advantages and limitations,so it is very difficult to simply evaluate the good points and bad points of the fusion algorithm. Whether an algorithm was selected to fuse object images was also depended upon the sensor types and special research purposes. Firstly,five fusion methods,i. e. IHS,Brovey,PCA,SFIM and Gram-Schmidt,were briefly described in the paper. And then visual judgment and quantitative statistical parameters were used to assess the five algorithms. Finally,in order to determine which one is the best suitable fusion method for land cover classification of IKONOS image,the maximum likelihood classification( MLC) was applied using the above five fusion images. The results showed that the fusion effect of SFIM transform and Gram-Schmidt transform were better than the other three image fusion methods in spatial details improvement and spectral information fidelity,and Gram-Schmidt technique was superior to SFIM transform in the aspect of expressing image details. The classification accuracy of the fused image using Gram-Schmidt and SFIM algorithms was higher than that of the other three image fusion methods,and the overall accuracy was greater than 98%. The IHS-fused image classification accuracy was the lowest,the overall accuracy and kappa coefficient were 83. 14% and 0. 76,respectively. Thus the IKONOS fusion images obtained by the Gram-Schmidt and SFIM were better for improving the land cover classification accuracy.

  19. Evaluating and optimizing horticultural regimes in space plant growth facilities

    Science.gov (United States)

    Berkovich, Y.; Chetirkin, R.; Wheeler, R.; Sager, J.

    In designing innovative Space Plant Growth Facilities (SPGF) for long duration space f ightl various limitations must be addressed including onboard resources: volume, energy consumption, heat transfer and crew labor expenditure. The required accuracy in evaluating onboard resources by using the equivalent mass methodology and applying it to the design of such facilities is not precise. This is due to the uncertainty of the structure and not completely understanding of the properties of all associated hardware, including the technology in these systems. We present a simple criteria of optimization for horticultural regimes in SPGF: Qmax = max [M · (EBI) 2 / (V · E · T) ], where M is the crop harvest in terms of total dry biomass in the plant growth system; EBI is the edible biomass index (harvest index), V is a volume occupied by the crop; E is the crop light energy supply during growth; T is the crop growth duration. The criterion reflects directly on the consumption of onboard resources for crop production. We analyzed the efficiency of plant crops and the environmental parameters by examining the criteria for 15 salad and 12 wheat crops from the data in the ALS database at Kennedy Space Center. Some following conclusion have been established: 1. The technology involved in growing salad crops on a cylindrical type surface provides a more meaningful Q-criterion; 2. Wheat crops were less efficient than leafy greens (salad crops) when examining resource utilization; 3. By increasing light intensity of the crop the efficiency of the resource utilization could decrease. Using the existing databases and Q-criteria we have found that the criteria can be used in optimizing design and horticultural regimes in the SPGF.

  20. The morphological /settlement pattern classification of South African settlements based on a settlement catchment approach, to inform facility allocation and service delivery

    CSIR Research Space (South Africa)

    Sogoni, Z

    2016-07-01

    Full Text Available / settlement pattern classification of South African settlements based on a settlement catchment approach, to inform facility allocation and service delivery Zukisa Sogoni Planning Africa Conference 2016 4 July 2Project Focus and Background • CSIR... services. • Purpose is to support application & planning for new investment & prevent “unsustainable” investments / White elephants. 3Outputs • National set of service delivery catchments • Profile information per individual catchment • Ranking...

  1. Polyp Morphology: An Interobserver Evaluation for the Paris Classification Among International Experts

    NARCIS (Netherlands)

    van Doorn, Sascha C.; Hazewinkel, Y.; East, James E.; van Leerdam, Monique E.; Rastogi, Amit; Pellisé, Maria; Sanduleanu-Dascalescu, Silvia; Bastiaansen, Barbara A. J.; Fockens, Paul; Dekker, Evelien

    2015-01-01

    OBJECTIVES: The Paris classification is an international classification system for describing polyp morphology. Thus far, the validity and reproducibility of this classification have not been assessed. We aimed to determine the interobserver agreement for the Paris classification among seven Western

  2. FLUX SENSOR EVALUATIONS AT THE ATR CRITICAL FACILITY

    International Nuclear Information System (INIS)

    Unruh, Troy; Rempe, Joy; Nigg, David; Imel, George; Harris, Jason; Bonebrake, Eric

    2010-01-01

    The Advanced Test Reactor (ATR) and the ATR Critical (ATRC) facilities lack real-time methods for detecting thermal neutron flux and fission reaction rates for irradiation capsules. Direct measurements of the actual power deposited into a test are now possible without resorting to complicated correction factors. In addition, it is possible to directly measure minor actinide fission reaction rates and to provide time-dependent monitoring of the fission reaction rate or fast/thermal flux during transient testing. A joint Idaho State University/Idaho National Laboratory ATR National Scientific User Facility (ATR NSUF) project was recently initiated to evaluate new real-time state-of-the-art in-pile flux detection sensors. Initially, the project is comparing the accuracy, response time, and long duration performance of French Atomic Energy Commission (CEA)-developed miniature fission chambers, specialized self-powered neutron detectors (SPNDs) by the Argentinean National Energy Commission (CNEA), specially developed commercial SPNDs, and back-to-back fission (BTB) chambers developed by Argonne National Laboratory (ANL). As discussed in this paper, specialized fixturing and software was developed by INL to facilitate these joint ISU/INL evaluations. Calculations were performed by ISU to assess the performance of and reduce uncertainties in flux detection sensors and compare data obtained from these sensors with existing integral methods employed at the ATRC. Ultimately, project results will be used to select the detector that can provide the best online regional ATRC power measurement. It is anticipated that project results may offer the potential to increase the ATRC's current power limit and its ability to perform low-level irradiation experiments. In addition, results from this effort will provide insights about the viability of using these detectors in the ATR. Hence, this effort complements current activities to improve ATR software tools, computational protocols

  3. Evaluating and comparing imaging techniques: a review and classification of study designs

    International Nuclear Information System (INIS)

    Freedman, L.S.

    1987-01-01

    The design of studies to evaluate and compare imaging techniques are reviewed. Thirteen principles for the design of studies of diagnostic accuracy are given. Because of the 'independence principle' these studies are not able directly to evaluate the contribution of a technique to clinical management. For the latter, the 'clinical value' study design is recommended. A classification of study designs is proposed in parallel with the standard classification of clinical trials. Studies of diagnostic accuracy are analogous to Phase II, whereas studies evaluating the contribution to clinical management correspond to the Phase III category. Currently the majority of published studies employ the Phase II design. More emphasis on Phase III studies is required. (author)

  4. St. Louis demonstration final report: refuse processing plant equipment, facilities, and environmental evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Fiscus, D.E.; Gorman, P.G.; Schrag, M.P.; Shannon, L.J.

    1977-09-01

    The results are presented of processing plant evaluations of the St. Louis-Union Electric Refuse Fuel Project, including equipment and facilities as well as assessment of environmental emissions at both the processing and the power plants. Data on plant material flows and operating parameters, plant operating costs, characteristics of plant material flows, and emissions from various processing operations were obtained during a testing program encompassing 53 calendar weeks. Refuse derived fuel (RDF) is the major product (80.6% by weight) of the refuse processing plant, the other being ferrous metal scrap, a marketable by-product. Average operating costs for the entire evaluation period were $8.26/Mg ($7.49/ton). The average overall processing rate for the period was 168 Mg/8-h day (185.5 tons/8-h day) at 31.0 Mg/h (34.2 tons/h). Future plants using an air classification system of the type used at the St. Louis demonstration plant will need an emissions control device for particulates from the large de-entrainment cyclone. Also in the air exhaust from the cyclone were total counts of bacteria and viruses several times higher than those of suburban ambient air. No water effluent or noise exposure problems were encountered, although landfill leachate mixed with ground water could result in contamination, given low dilution rates.

  5. Evaluation of Urinary Tract Dilation Classification System for Grading Postnatal Hydronephrosis.

    Science.gov (United States)

    Hodhod, Amr; Capolicchio, John-Paul; Jednak, Roman; El-Sherif, Eid; El-Doray, Abd El-Alim; El-Sherbiny, Mohamed

    2016-03-01

    We assessed the reliability and validity of the Urinary Tract Dilation classification system as a new grading system for postnatal hydronephrosis. We retrospectively reviewed charts of patients who presented with hydronephrosis from 2008 to 2013. We included patients diagnosed prenatally and those with hydronephrosis discovered incidentally during the first year of life. We excluded cases involving urinary tract infection, neurogenic bladder and chromosomal anomalies, those associated with extraurinary congenital malformations and those with followup of less than 24 months without resolution. Hydronephrosis was graded postnatally using the Society for Fetal Urology system, and then the management protocol was chosen. All units were regraded using the Urinary Tract Dilation classification system and compared to the Society for Fetal Urology system to assess reliability. Univariate and multivariate analyses were performed to assess the validity of the Urinary Tract Dilation classification system in predicting hydronephrosis resolution and surgical intervention. A total of 490 patients (730 renal units) were eligible to participate. The Urinary Tract Dilation classification system was reliable in the assessment of hydronephrosis (parallel forms 0.92). Hydronephrosis resolved in 357 units (49%), and 86 units (12%) were managed by surgical intervention. The remainder of renal units demonstrated stable or improved hydronephrosis. Multivariate analysis revealed that the likelihood of surgical intervention was predicted independently by Urinary Tract Dilation classification system risk group, while Society for Fetal Urology grades were predictive of likelihood of resolution. The Urinary Tract Dilation classification system is reliable for evaluation of postnatal hydronephrosis and is valid in predicting surgical intervention. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Evaluation of rubber seal products for gamma facilities

    International Nuclear Information System (INIS)

    Sobhy, M.S.; Shafy, M.A.; Shahin, F.

    2005-01-01

    Ageing behavior by employing the prolonged exposures of high-energy radiation such as gamma-rays on the physicomechanical properties of some rubber seal products are studied. The proposed binary-rubber blends, SBR/NBR, EPDM/NBR and EPDM/EPM. have overcome their problem of inhomogeneity and incompatibility between the two rubber phases. Such enhancements are acquired by either the replacement of part of NBR by SBR during mastication, or the incorporation of maleic anhydride. Results show that the EPDM/EPM rubber blend has possessed the radiation resistance property towards the deterioration due to higher gamma-irradiation dose. The SEM images have c early observed the role of the used antioxidant, where a thin film is usually produced, degraded; with the appearance of surface cracks, and repaired with further gamma-irradiation up to high doses. Such enhancement is necessary for the definition of the requirements to be put on rubber seal materials. Finally, these products ought to assure the quality control in production and evaluate their application suitability that may employ in the pneumatic system in gamma facility

  7. Evaluation of bulk shield for the JHP facilities

    International Nuclear Information System (INIS)

    Uwamino, Yoshitomo; Shibata, Tokushi

    1991-01-01

    In the Japanese Hadron Project (JHP), a 1-GeV 200-μA proton beam will be handled, and the radiation shield of the facility will be very massive concrete and iron lump. Since the constructing cost is strongly affected by the shielding design, the design must be severely performed. The neutron yield in thin targets and a copper beam dump was calculated by the HETC-KFA-2 Monte Carlo code. For the evaluation of the calculational accuracy, the calculational results were compared with the experimental data by Cierjacks and Raupp. The calculated result of heavy element agreed well with the experiment at a low energy region, E n n >100 MeV) of 90 deg close to the calculated one of about 60 deg in the absolute value. The high energy neutron transport in a 5-m-thick iron slab and in an 8-m-thick ordinary concrete slab was calculated with the HETC code and also with the discrete ordinates transport code, ANISN. In the ANISN calculation, the DLC-87/HILO and the DLC-128/LAHIMAC group cross sections were used. The ANISN calculation with the LAHIMAC cross sections gave strong underestimation compared with the HETC calculation. The difference of the shielding lengths calculated by the HETC code and by the ANISN code used with the HILO cross sections was smaller than 6% for the both iron and concrete cases. (author)

  8. Evaluation of normalization methods for cDNA microarray data by k-NN classification

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Wei; Xing, Eric P; Myers, Connie; Mian, Saira; Bissell, Mina J

    2004-12-17

    Non-biological factors give rise to unwanted variations in cDNA microarray data. There are many normalization methods designed to remove such variations. However, to date there have been few published systematic evaluations of these techniques for removing variations arising from dye biases in the context of downstream, higher-order analytical tasks such as classification. Ten location normalization methods that adjust spatial- and/or intensity-dependent dye biases, and three scale methods that adjust scale differences were applied, individually and in combination, to five distinct, published, cancer biology-related cDNA microarray data sets. Leave-one-out cross-validation (LOOCV) classification error was employed as the quantitative end-point for assessing the effectiveness of a normalization method. In particular, a known classifier, k-nearest neighbor (k-NN), was estimated from data normalized using a given technique, and the LOOCV error rate of the ensuing model was computed. We found that k-NN classifiers are sensitive to dye biases in the data. Using NONRM and GMEDIAN as baseline methods, our results show that single-bias-removal techniques which remove either spatial-dependent dye bias (referred later as spatial effect) or intensity-dependent dye bias (referred later as intensity effect) moderately reduce LOOCV classification errors; whereas double-bias-removal techniques which remove both spatial- and intensity effect reduce LOOCV classification errors even further. Of the 41 different strategies examined, three two-step processes, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, all of which removed intensity effect globally and spatial effect locally, appear to reduce LOOCV classification errors most consistently and effectively across all data sets. We also found that the investigated scale normalization methods do not reduce LOOCV classification error. Using LOOCV error of k-NNs as the evaluation criterion, three double

  9. Educational Facility Evaluations of Primary Schools in Rural Honduras: Departments of Cortes and Meambar.

    Science.gov (United States)

    Council of Educational Facility Planners, International, Scottsdale, AZ.

    A team of 11 educational facility planners and architects from the United States and Canada conducted a facility evaluation of schools in the rural areas of Meambar and Cortes, Honduras. Team members were all part of the Council of Educational Facility Planners, International and traveled to Honduras under the auspices of a Christian mission…

  10. User's guide for evaluating physical security capabilities of nuclear facilities by the EASI method

    International Nuclear Information System (INIS)

    Bennett, H.A.

    1977-06-01

    This handbook is a guide for evaluating physical security of nuclear facilities using the ''Estimate of Adversary Sequence Interruption (EASI)'' method and a hand-held programmable calculator. The handbook is intended for use by personnel at facilities where special nuclear materials are used, processed, or stored. It may also be used as a design aid for such facilities by potential licensees

  11. Design evaluaion: pneumatic transport and classification

    International Nuclear Information System (INIS)

    McNair, J.M.

    1979-10-01

    This report describes the evaluation of selected design features of the cold engineering scale pneumatic transport and classification subsystems used in the development of the head-end equipment for HTGR fuel reprocessing. The report identifies areas that require further design effort and evaluation of alternatives prior to the design of the HTGR reference recycle facility (HRRF). Seven areas in the transport subsystem and three in the classification subsystem were selected for evaluation. Seventeen specific recommendations are presented for further design effort

  12. SRTC criticality technical review: Nuclear Criticality Safety Evaluation 93-18 Uranium Solidification Facility's Waste Handling Facility

    International Nuclear Information System (INIS)

    Rathbun, R.

    1993-01-01

    Separate review of NMP-NCS-930058, open-quotes Nuclear Criticality Safety Evaluation 93-18 Uranium Solidification Facility's Waste Handling Facility (U), August 17, 1993,close quotes was requested of SRTC Applied Physics Group. The NCSE is a criticality assessment to determine waste container uranium limits in the Uranium Solidification Facility's Waste Handling Facility. The NCSE under review concludes that the NDA room remains in a critically safe configuration for all normal and single credible abnormal conditions. The ability to make this conclusion is highly dependent on array limitation and inclusion of physical barriers between 2x2x1 arrays of boxes containing materials contaminated with uranium. After a thorough review of the NCSE and independent calculations, this reviewer agrees with that conclusion

  13. Engineering evaluation/cost analysis for the 105-DR and 105-F Reactor facilities and ancillary facilities

    International Nuclear Information System (INIS)

    Coenenberg, E.T.

    1998-01-01

    This document presents the results of an engineering evaluation/cost analysis (EE/CA) that was conducted to evaluate alternatives to address final disposition of the 105-DR and 105-F Reactor Buildings (subsequently referred to as facilities), including the fuel storage basins (FSB) and below-grade portions of the reactors, excluding the reactor blocks. The reactor blocks will remain in a safe storage mode for up to 75 years as identified in the Record the Decision (ROD) (58 FR 48509) for the Environmental Impact Statement (EIS), Decommissioning of Eight Surplus Production Reactors at the Hanford Site, Richland, Washington (DOE 1992a). This EE/CA also addresses final disposition of four ancillary facilities: 116-D and 116-DR Exhaust Air Stacks, 117-DR Exhaust Filter Building, and 119-DR Exhaust Air Sample Building. The 105-DR and 105-F facilities are located in the 100-D and 100-F Areas of the Hanford Site. In November 1989, the 100 Area of the Hanford Site was placed on the U.S. Environmental Protection Agency's (EPA) National Priorities List (NPL) under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The 100 Area NPL includes the 100-D Area (which includes the 100-DR site) and the 100-F Area, which are in various stages of the remediation process. It has been determined by DOE that hazardous substances in the 105-DR, 105-F, and the four ancillary facilities may present a potential threat to human health or the environment, and that a non-time critical removal action at these facilities is warranted. To help determine the most appropriate action, DOE, in cooperation with the Washington State Department of Ecology (Ecology) and the EPA, has prepared this EE/CA. The scope of the evaluation includes the 105-DR and 105-F facilities and the four ancillary facilities. The 116-DR and 117-DR facilities are located within the boundaries of the 105-DR Large Sodium Fire Facility Treatment, Storage, and Disposal (TSD) unit, which is

  14. Contract-program evaluation: Impact of the DRG classification system on hospitals' outputs

    OpenAIRE

    Alves, Helder António Pereira Gomes

    2010-01-01

    A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics The present work project aims at evaluating the impact of contract-program implementation in 2003 and of incentives created in 2007 on hospital output, under the DRG inpatient classification system. A sample of five Portuguese acute public district hospitals was chosen as sample, between 2002 and 2007. Results of hypothesis testing ...

  15. The science of stakeholder engagement in research: classification, implementation, and evaluation

    OpenAIRE

    Goodman, Melody S.; Sanders Thompson, Vetta L.

    2017-01-01

    In this commentary, we discuss the science of stakeholder engagement in research. We propose a classification system with definitions to determine where projects lie on the stakeholder engagement continuum. We discuss the key elements of implementation and evaluation of stakeholder engagement in research posing key questions to consider when doing this work. We commend and critique the work of Hamilton et al. in their multilevel stakeholder engagement in a VA implementation trial of evidence-...

  16. Hazard evaluation of The International Fusion Materials Irradiation Facility

    Energy Technology Data Exchange (ETDEWEB)

    Burgazzi, Luciano [ENEA-Centro Ricerche ' Ezio Clementel' , Advanced Physics Technology Division, Via Martiri di Monte Sole, 4, 40129 Bologna (Italy)]. E-mail: burgazzi@bologna.enea.it

    2005-01-15

    The International Fusion Materials Irradiation Facility (IFMIF) is aimed to provide an intense neutron source by a high current deuteron linear accelerator and a high-speed lithium flow target, for testing candidate materials for fusion. Liquid lithium is being circulated through a loop and is kept at a temperature above its freezing point. In the frame of the design phase called Key Element technology Phase (KEP), jointly performed by an international team to verify the most important risk factors, safety assessment of the whole plant has been required in order to identify the hazards associated with the plant operation. This paper discusses the safety assessments that were performed and their outcome: Failure Mode and Effect Analysis (FMEA) approach has been adopted in order to accomplish the task. Main conclusions of the study is that, on account of the safety and preventive measures adopted, potential plant related hazards are confined within the IFMIF security boundaries and great care must be exercised to protect workers and site personnel from operating the plant. The analysis has provided as a result a set of Postulated Initiating Events (PIEs), that is off-normal events, that could result in hazardous consequences for the plant, together with the total frequency and the list of component failures which could induce the PIE: this assures the exhaustive list of major initiating events of accident sequences, helpful to the further accident sequence analysis phase. Finally, for each one of the individuated PIEs, the evaluation of the accident evolution, in terms of effects on the plant and relative countermeasures, has allowed to verify that adequate measures are being taken both to prevent the accident occurrence and to cope with the accident consequences, thus assuring the fulfilment of the safety requirements.

  17. Evaluation of physical facilities and processing operations of major ...

    African Journals Online (AJOL)

    ADEYEYE

    abattoirs were as a result of failure to enforce the use of standard facilities in carrying out abattoir operations and general maintenance ... incinerator, chemical treatment and disposal. Sub- .... Veterinary laboratory .... sustainable food security.

  18. Facility to evaluate street lightning solutionsin a realistic urban setting

    DEFF Research Database (Denmark)

    Andersen, Jakob Munkgaard; Thorseth, Anders; Dam-Hansen, Carsten

    2015-01-01

    This paper describes a new large scale outdoor testing facility for street lighting solutions, that has been establish in Denmark for both research and demonstration purposes. The facility is fitted with lamp posts with an array of sensors and connections to allow for monitoring and control...... of lighting solutions under test. Initial data suggests a 75% reduction in energy usage from use of LED luminaries combined with traffic monitoring systems could be achievable....

  19. Developing a contributing factor classification scheme for Rasmussen's AcciMap: Reliability and validity evaluation.

    Science.gov (United States)

    Goode, N; Salmon, P M; Taylor, N Z; Lenné, M G; Finch, C F

    2017-10-01

    One factor potentially limiting the uptake of Rasmussen's (1997) Accimap method by practitioners is the lack of a contributing factor classification scheme to guide accident analyses. This article evaluates the intra- and inter-rater reliability and criterion-referenced validity of a classification scheme developed to support the use of Accimap by led outdoor activity (LOA) practitioners. The classification scheme has two levels: the system level describes the actors, artefacts and activity context in terms of 14 codes; the descriptor level breaks the system level codes down into 107 specific contributing factors. The study involved 11 LOA practitioners using the scheme on two separate occasions to code a pre-determined list of contributing factors identified from four incident reports. Criterion-referenced validity was assessed by comparing the codes selected by LOA practitioners to those selected by the method creators. Mean intra-rater reliability scores at the system (M = 83.6%) and descriptor (M = 74%) levels were acceptable. Mean inter-rater reliability scores were not consistently acceptable for both coding attempts at the system level (M T1  = 68.8%; M T2  = 73.9%), and were poor at the descriptor level (M T1  = 58.5%; M T2  = 64.1%). Mean criterion referenced validity scores at the system level were acceptable (M T1  = 73.9%; M T2  = 75.3%). However, they were not consistently acceptable at the descriptor level (M T1  = 67.6%; M T2  = 70.8%). Overall, the results indicate that the classification scheme does not currently satisfy reliability and validity requirements, and that further work is required. The implications for the design and development of contributing factors classification schemes are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Evaluation of the Netherlands' International Test Facility for Smart Grids

    Energy Technology Data Exchange (ETDEWEB)

    Palmintier, Bryan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pratt, Annabelle [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-06-01

    The Netherlands Enterprise Agency (Rijksdienst voor Ondernemend Nederland, or RVO) engaged the U.S. National Renewable Energy Laboratory (NREL) for two primary purposes: to evaluate the International Test Facility for Smart Grids (ITF) sponsored by RVO and to learn best practices for integrated test facilities from NREL's Energy Systems Integration Facility (ESIF). This report covers the ITF evaluation and is largely based on a one-week visit to the Netherlands in November 2014.

  1. Evaluate of environment quality for γ irradiation facilities using fuzzy comprehensive judgment method

    International Nuclear Information System (INIS)

    Ha Yiming

    2002-01-01

    The environment quality of Jining Irradiation Centre new γ radiation facility was evaluated by fuzzy comprehensive judgment method. The result showed that the place of γ radiation facility was well and the measures of radiate shelter and environment protect were effective. The environment quality of its area was not obvious change and the result of environment evaluation was first-rate

  2. Professional Development through Organizational Assessment: Using APPA's Facilities Management Evaluation Program

    Science.gov (United States)

    Medlin, E. Lander; Judd, R. Holly

    2013-01-01

    APPA's Facilities Management Evaluation Program (FMEP) provides an integrated system to optimize organizational performance. The criteria for evaluation not only provide a tool for organizational continuous improvement, they serve as a compelling leadership development tool essential for today's facilities management professional. The senior…

  3. Research on evaluating water resource resilience based on projection pursuit classification model

    Science.gov (United States)

    Liu, Dong; Zhao, Dan; Liang, Xu; Wu, Qiuchen

    2016-03-01

    Water is a fundamental natural resource while agriculture water guarantees the grain output, which shows that the utilization and management of water resource have a significant practical meaning. Regional agricultural water resource system features with unpredictable, self-organization, and non-linear which lays a certain difficulty on the evaluation of regional agriculture water resource resilience. The current research on water resource resilience remains to focus on qualitative analysis and the quantitative analysis is still in the primary stage, thus, according to the above issues, projection pursuit classification model is brought forward. With the help of artificial fish-swarm algorithm (AFSA), it optimizes the projection index function, seeks for the optimal projection direction, and improves AFSA with the application of self-adaptive artificial fish step and crowding factor. Taking Hongxinglong Administration of Heilongjiang as the research base and on the basis of improving AFSA, it established the evaluation of projection pursuit classification model to agriculture water resource system resilience besides the proceeding analysis of projection pursuit classification model on accelerating genetic algorithm. The research shows that the water resource resilience of Hongxinglong is the best than Raohe Farm, and the last 597 Farm. And the further analysis shows that the key driving factors influencing agricultural water resource resilience are precipitation and agriculture water consumption. The research result reveals the restoring situation of the local water resource system, providing foundation for agriculture water resource management.

  4. Evaluation of classification method of lung lobe for multi-slice CT images

    International Nuclear Information System (INIS)

    Sakurai, Kousuke; Matsuhiro, Mikio; Saita, Shinsuke

    2010-01-01

    Recently, due to the introduction of multi-slice CT, to obtain a high resolution 3D CT image is possible in a short time. The temporal and spatial resolutions are high, so a highly accurate 3D image analysis is possible. To develop a structure analysis of the lung is needed and to be used as a fundamental technology for early detection of the disease. By separating the lung into lung lobes may provide important information for analysis, diagnosis and treatment of lung diseases. Therefore in this report, we adapt to abnormality example with the classification algorithms using the anatomical information of the bronchus, the pulmonary vein and interlobar fissure information, we evaluate the classification. (author)

  5. Classification of the coefficients of variation of parameters evaluated in Japanese quail experiments

    Directory of Open Access Journals (Sweden)

    DHV Leal

    2014-06-01

    Full Text Available The objective of this study was to design a classification range of the coefficients of variation (CV of traits used in experiments with eggtype Japanese quails (Coturnix coturnix japonica. The journal Revista Brasileira de Zootecnia was systematically reviewed, using the key word 'quail' during the period of January, 2000 to 2010. The CV of feed intake (g/bird/d, egg production (%/bird/d, egg weight (g, egg mass (g/bird/d, feed conversion ratio per dozen eggs (g/dozen, feed conversion ratio per egg mass (g/g, and egg specific gravity (g/mL were collected. For each parameter, CV were classified using the following median (MD and pseudo-sigma (PS ratio as follows: low (CV MD + 2PS. According to the results, it was concluded that each parameter has a specific classification range that should be taken into account when evaluating experimental precision.

  6. Survey of computer codes applicable to waste facility performance evaluations

    International Nuclear Information System (INIS)

    Alsharif, M.; Pung, D.L.; Rivera, A.L.; Dole, L.R.

    1988-01-01

    This study is an effort to review existing information that is useful to develop an integrated model for predicting the performance of a radioactive waste facility. A summary description of 162 computer codes is given. The identified computer programs address the performance of waste packages, waste transport and equilibrium geochemistry, hydrological processes in unsaturated and saturated zones, and general waste facility performance assessment. Some programs also deal with thermal analysis, structural analysis, and special purposes. A number of these computer programs are being used by the US Department of Energy, the US Nuclear Regulatory Commission, and their contractors to analyze various aspects of waste package performance. Fifty-five of these codes were identified as being potentially useful on the analysis of low-level radioactive waste facilities located above the water table. The code summaries include authors, identification data, model types, and pertinent references. 14 refs., 5 tabs

  7. Performance evaluation of the Solar Building Test Facility

    Science.gov (United States)

    Jensen, R. N.

    1981-01-01

    The general performance of the NASA Solar Building Test Facility (SBTF) and its subsystems and components over a four year operational period is discussed, and data are provided for a typical one year period. The facility consists of a 4645 sq office building modified to accept solar heated water for operation of an absorption air conditioner and a baseboard heating system. An adjoining 1176 sq solar flat plate collector field with a 114 cu tank provides the solar heated water. The solar system provided 57 percent of the energy required for heating and cooling on an annual basis. The average efficiency of the solar collectors was 26 percent over a one year period.

  8. A novel evaluation of two related and two independent algorithms for eye movement classification during reading.

    Science.gov (United States)

    Friedman, Lee; Rigas, Ioannis; Abdulin, Evgeny; Komogortsev, Oleg V

    2018-05-15

    Nystrӧm and Holmqvist have published a method for the classification of eye movements during reading (ONH) (Nyström & Holmqvist, 2010). When we applied this algorithm to our data, the results were not satisfactory, so we modified the algorithm (now the MNH) to better classify our data. The changes included: (1) reducing the amount of signal filtering, (2) excluding a new type of noise, (3) removing several adaptive thresholds and replacing them with fixed thresholds, (4) changing the way that the start and end of each saccade was determined, (5) employing a new algorithm for detecting PSOs, and (6) allowing a fixation period to either begin or end with noise. A new method for the evaluation of classification algorithms is presented. It was designed to provide comprehensive feedback to an algorithm developer, in a time-efficient manner, about the types and numbers of classification errors that an algorithm produces. This evaluation was conducted by three expert raters independently, across 20 randomly chosen recordings, each classified by both algorithms. The MNH made many fewer errors in determining when saccades start and end, and it also detected some fixations and saccades that the ONH did not. The MNH fails to detect very small saccades. We also evaluated two additional algorithms: the EyeLink Parser and a more current, machine-learning-based algorithm. The EyeLink Parser tended to find more saccades that ended too early than did the other methods, and we found numerous problems with the output of the machine-learning-based algorithm.

  9. Evaluation and Classification of Syntax Usage in Determining Short-Text Semantic Similarity

    Directory of Open Access Journals (Sweden)

    V. Batanović

    2014-06-01

    Full Text Available This paper outlines and categorizes ways of using syntactic information in a number of algorithms for determining the semantic similarity of short texts. We consider the use of word order information, part-of-speech tagging, parsing and semantic role labeling. We analyze and evaluate the effects of syntax usage on algorithm performance by utilizing the results of a paraphrase detection test on the Microsoft Research Paraphrase Corpus. We also propose a new classification of algorithms based on their applicability to languages with scarce natural language processing tools.

  10. The science of stakeholder engagement in research: classification, implementation, and evaluation.

    Science.gov (United States)

    Goodman, Melody S; Sanders Thompson, Vetta L

    2017-09-01

    In this commentary, we discuss the science of stakeholder engagement in research. We propose a classification system with definitions to determine where projects lie on the stakeholder engagement continuum. We discuss the key elements of implementation and evaluation of stakeholder engagement in research posing key questions to consider when doing this work. We commend and critique the work of Hamilton et al. in their multilevel stakeholder engagement in a VA implementation trial of evidence-based quality improvement in women's health primary care. We also discuss the need for more work in this area to enhance the science of stakeholder engagement in research.

  11. A probabilistic risk assessment of the LLNL Plutonium facility's evaluation basis fire operational accident

    International Nuclear Information System (INIS)

    Brumburgh, G.

    1994-01-01

    The Lawrence Livermore National Laboratory (LLNL) Plutonium Facility conducts numerous involving plutonium to include device fabrication, development of fabrication techniques, metallurgy research, and laser isotope separation. A Safety Analysis Report (SAR) for the building 332 Plutonium Facility was completed rational safety and acceptable risk to employees, the public, government property, and the environment. This paper outlines the PRA analysis of the Evaluation Basis Fire (EDF) operational accident. The EBF postulates the worst-case programmatic impact event for the Plutonium Facility

  12. Evaluation of natural phenomena hazards as part of safety assessments for nuclear facilities

    International Nuclear Information System (INIS)

    Kot, C.A.; Hsieh, B.J.; Srinivasan, M.G.; Shin, Y.W.

    1995-02-01

    The continued operation of existing US Department of Energy (DOE) nuclear facilities and laboratories requires a safety reassessment based on current criteria and guidelines. This also includes evaluations for the effects of Natural Phenomena Hazards (NPH), for which these facilities may not have been designed. The NPH evaluations follow the requirements of DOE Order 5480.28, Natural Phenomena Hazards Mitigation (1993) which establishes NPH Performance Categories (PCs) for DOE facilities and associated target probabilistic performance goals. These goals are expressed as the mean annual probability of exceedance of acceptable behavior for structures, systems and components (SSCs) subjected to NPH effects. The assignment of an NPH Performance Category is based on the overall hazard categorization (low, moderate, high) of a facility and on the function of an SSC under evaluation (DOE-STD-1021, 1992). Detailed guidance for the NPH analysis and evaluation criteria are also provided (DOE-STD-1020, 1994). These analyses can be very resource intensive, and may not be necessary for the evaluation of all SSCs in existing facilities, in particular for low hazard category facilities. An approach relying heavily on screening inspections, engineering judgment and use of NPH experience data (S. J. Eder et al., 1993), can minimize the analytical effort, give reasonable estimates of the NPH susceptibilities, and yield adequate information for an overall safety evaluation of the facility. In the following sections this approach is described in more detail and is illustrated by an application to a nuclear laboratory complex

  13. Evaluation of alternatives for the future of facilities at the Western New York Nuclear Service Center

    International Nuclear Information System (INIS)

    1978-08-01

    Regulatory considerations are discussed. Alternatives for the continued operation or decommissioning of the state-licensed burial area, the low-level waste treatment facilities, and the NRC licensed burial area are evaluated. Radiological impact analyses were also performed for alternatives on other facilities

  14. EVALUATION OF SERVICES’ QUALITY IN UPPER SILESIA ACCOMMODATION FACILITIES

    Directory of Open Access Journals (Sweden)

    Iwona Cieślik

    2013-12-01

    Full Text Available This paper presents the results of study about impact of accommodation services’ quality, particularly quality of work and qualifications of staff, on the guests’ opinion, and thus promoting the accommodation facilities, and making a choice of a hotel in the Upper Silesia. The study involved 200 people, taking into account their gender, age, place of residence, education and occupational status. The research tool was a survey questionnaire. The results indicate close correlation between the quality of staff services (individual approach, aesthetics, discretion, understanding and the customer is satisfaction. Particular attention was paid to the quality of service by the guests with high professional status, and higher education.

  15. Design and Evaluation of Smart Glasses for Food Intake and Physical Activity Classification.

    Science.gov (United States)

    Chung, Jungman; Oh, Wonjoon; Baek, Dongyoub; Ryu, Sunwoong; Lee, Won Gu; Bang, Hyunwoo

    2018-02-14

    This study presents a series of protocols of designing and manufacturing a glasses-type wearable device that detects the patterns of temporalis muscle activities during food intake and other physical activities. We fabricated a 3D-printed frame of the glasses and a load cell-integrated printed circuit board (PCB) module inserted in both hinges of the frame. The module was used to acquire the force signals, and transmit them wirelessly. These procedures provide the system with higher mobility, which can be evaluated in practical wearing conditions such as walking and waggling. A performance of the classification is also evaluated by distinguishing the patterns of food intake from those physical activities. A series of algorithms were used to preprocess the signals, generate feature vectors, and recognize the patterns of several featured activities (chewing and winking), and other physical activities (sedentary rest, talking, and walking). The results showed that the average F1 score of the classification among the featured activities was 91.4%. We believe this approach can be potentially useful for automatic and objective monitoring of ingestive behaviors with higher accuracy as practical means to treat ingestive problems.

  16. Procedure for Prioritization of Natural Phenomena Hazards Evaluations for Existing DOE Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Conrads, T.J., Westinghouse Hanford

    1996-05-07

    This document describes the procedure to be used for the prioritization for natural phenomena hazards evaluations of existing DOE facilities in conformance with DOE Order 5480.28, `Natural Phenomena Hazards Mitigation.`

  17. Evaluation of a Low-Cost Salmon Production Facility; 1988 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, James M.; Olson, Todd

    1989-05-01

    This fiscal year 1988 study sponsored by the Bonneville Power Administration evaluates an existing, small-scale salmon production facility operated and maintained by the Clatsop County Economic Development Committee's Fisheries Project.

  18. Evaluation of Island and Nearshore Confined Disposal Facility Alternatives, Pascagoula River Harbor Dredged Material Management Plan

    National Research Council Canada - National Science Library

    Bunch, Barry

    2003-01-01

    ...) for the Federal navigation project at Pascagoula, MS. The studies focused on evaluating an option under consideration for the placement of dredged material in an island confined disposal facility (CDF...

  19. Consistent natural phenomena design and evaluation guidelines for U.S. Department of Energy facilities

    International Nuclear Information System (INIS)

    Murray, R.C.; Short, S.A.

    1989-01-01

    Uniform design and evaluation guidelines for protection against natural phenomena hazards such as earthquakes, extreme winds, and flooding for facilities at Department of Energy (DOE) sites throughout the United States have been developed. The guidelines apply to design of new facilities and to evaluation or modification of existing facilities. These guidelines are an approach for design or evaluation for mitigating the effects of natural phenomena hazards. These guidelines are intended to control the level of conservatism introduced in the design/evaluation process such that all hazards are treated on a reasonably consistent and uniform basis and such that the level of conservatism is appropriate for facility characteristics such as importance, cost, and hazards to on-site personnel, the general public, and the environment. The philosophy and goals of these guidelines are covered by this paper

  20. CSER 94-012: Criticality safety evaluation report for 340 Facility

    International Nuclear Information System (INIS)

    Altschuler, S.J.

    1995-01-01

    This Criticality Safety Evaluation Report (CSER) covers the 340 Facility which acts as a collecting point for liquid and solid waste from various facilities in the 300 Area. Criticality safety is achieved by controlling the amount and concentration of the fissionable material sent to the 340 Facility from the originating facilities in the 300 Area, a method similar to that used elsewhere at Hanford for the waste tank farms. Unlike those, however, the waste received at the 340 Facility will be far less radioactive. It is concluded that present operations meet the two contingency criterion. The facility will still be safely subcritical even after two independent and concurrent failures (either of equipment or administrative controls). The solid waste storage and liquid waste will be managed separately. The solid waste storage area is classified as exempt because it contains less than 15 grams of fissionable materials. The Radioactive Liquid Waste System is classified as isolated because it contains less than one third of a minimum critical mass. The criticality safety of the 340 Facility devoted to the Radioactive Liquid Waste System (RLWS) is assured by the form and concentration of the fissile material and could also be classified as a limited control facility. However, the 340 Facility has been operated as an isolated facility which results in a more conservative limit

  1. Materials evaluation programs at the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Gee, J.T.; Iverson, D.C.; Bickford, D.F.

    1992-01-01

    The Savannah River Site (SRS) has been operating a nuclear fuel cycle since the 1950s to produce nuclear materials in support of the national defense effort. About 83 million gallons of high-level waste produced since operations began has been consolidated by evaporation into 33 million gallons at the waste tank farm. The Department of Energy authorized the construction of the Defense Waste Processing Facility (DWPF), the function of which is to immobilize the waste as a durable borosilicate glass contained in stainless steel canisters prior to the placement of the canisters in a federal repository. The DWPF is now mechanically complete and is undergoing commissioning and run-in activities. A brief description of the DWPF process is provided

  2. Evaluating health risks in communities near nuclear facilities

    International Nuclear Information System (INIS)

    Ruttenber, A.J.

    1992-01-01

    Over the past 10 years, epidemiologic studies have been the most popular approach to examining health risks to populations near nuclear facilities. A review of these studies has identified a number of methodologic problems, particularly with regard to establishing causal relations between radiation exposure and disease. Recently, in the United States, dose reconstruction and risk assessment projects have been conducted as alternatives to epidemiologic studies. This paper reviews the problems associated with epidemiologic studies and discusses how dose reconstruction and risk assessment can serve as alternatives to epidemiologic studies. Examples are also provided to demonstrate how these techniques can be used to explore the feasibility of epidemiologic studies, and how dose reconstruction data can improve the quality of epidemiologic studies

  3. Evaluation of tecnological reliability of wind turbine facility Gibara 2

    International Nuclear Information System (INIS)

    Torres Valle, Antonio; Martínez Martín, Erich

    2016-01-01

    Renewable energy, particularly wind, will occupy an important place in the coming decades, marked by the depletion of fossil fuel sources. In Cuba significant growth in the use of these energy sourcesis forecasted. For this reason is importantthe creation of reliable technology to ensure that future mission. The paper proposes as its central objective, the analysis of reliability of Wind Farm Gibara 2 starting from its representation based on the methodology of fault tree and to recommend some possible applications of the results. An essential step in the research is the determination of participating components in the fault tree and processing of the available reliability database at the Wind Farm Gibara 2. The document essentially helpsin the identification of the main contributors to the unavailability of facilities and optimizing maintenance policy. (author)

  4. Advanced computing for evaluating facility needs and enhancing sustainable development of public facility investment plan

    CSIR Research Space (South Africa)

    Green, Cheri A

    2009-06-01

    Full Text Available hall investment for eThekwini municipality in South Africa is used to illustrate the methodology of matching supply and demand spatially across urban and rural areas. The GIS analysis ensures that the evaluation of backlogs and proposals for new...

  5. Design and evaluation guidelines for Department of Energy facilities subjected to natural phenomena hazards

    International Nuclear Information System (INIS)

    Kennedy, R.P.; Short, S.A.; McDonald, J.R.; McCann, M.W. Jr.; Murray, R.C.; Hill, J.R.

    1990-06-01

    The Department of Energy (DOE) and the DOE Natural Phenomena Hazards Panel have developed uniform design and evaluation guidelines for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of the guidelines is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. The guidelines apply to both new facilities (design) and existing facilities (evaluation, modification, and upgrading). The intended audience is primarily the civil/structural or mechanical engineers conducting the design or evaluation of DOE facilities. The likelihood of occurrence of natural phenomena hazards at each DOE site has been evaluated by the DOE Natural Phenomena Hazard Program. Probabilistic hazard models are available for earthquake, extreme wind/tornado, and flood. Alternatively, site organizations are encouraged to develop site-specific hazard models utilizing the most recent information and techniques available. In this document, performance goals and natural hazard levels are expressed in probabilistic terms, and design and evaluation procedures are presented in deterministic terms. Design/evaluation procedures conform closely to common standard practices so that the procedures will be easily understood by most engineers. Performance goals are expressed in terms of structure or equipment damage to the extent that: (1) the facility cannot function; (2) the facility would need to be replaced; or (3) personnel are endangered. 82 refs., 12 figs., 18 tabs

  6. Design and evaluation guidelines for Department of Energy facilities subjected to natural phenomena hazards

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, R.P. (Structural Mechanics Consulting, Inc., Yorba Linda, CA (USA)); Short, S.A. (ABB Impell Corp., Mission Viejo, CA (USA)); McDonald, J.R. (Texas Tech Univ., Lubbock, TX (USA)); McCann, M.W. Jr. (Benjamin (J.R.) and Associates, Inc., Mountain View, CA (USA)); Murray, R.C. (Lawrence Livermore National Lab., CA (USA)); Hill, J.R. (USDOE Assistant Secretary for Environment, Safety, and He

    1990-06-01

    The Department of Energy (DOE) and the DOE Natural Phenomena Hazards Panel have developed uniform design and evaluation guidelines for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of the guidelines is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. The guidelines apply to both new facilities (design) and existing facilities (evaluation, modification, and upgrading). The intended audience is primarily the civil/structural or mechanical engineers conducting the design or evaluation of DOE facilities. The likelihood of occurrence of natural phenomena hazards at each DOE site has been evaluated by the DOE Natural Phenomena Hazard Program. Probabilistic hazard models are available for earthquake, extreme wind/tornado, and flood. Alternatively, site organizations are encouraged to develop site-specific hazard models utilizing the most recent information and techniques available. In this document, performance goals and natural hazard levels are expressed in probabilistic terms, and design and evaluation procedures are presented in deterministic terms. Design/evaluation procedures conform closely to common standard practices so that the procedures will be easily understood by most engineers. Performance goals are expressed in terms of structure or equipment damage to the extent that: (1) the facility cannot function; (2) the facility would need to be replaced; or (3) personnel are endangered. 82 refs., 12 figs., 18 tabs.

  7. Classification of High-Rise Residential Building Facilities: A Descriptive Survey on 170 Housing Scheme in Klang Valley

    OpenAIRE

    Abd Wahab Siti Rashidah Hanum; Che Ani Adi Irfan; Sairi Ahmad; Mohd Tawil Norngainy; Abd Razak Mohd Zulhanif

    2016-01-01

    High-rise residential building is a type of housing that has multi-dwelling units built on the same land. This type of housing has become popular each year in urban area due to the increasing cost of land. There are several common facilities provided in high-rise residential building. For example playground, swimming pool, gymnasium, 24 hours security system such as CCTV, access card and so on. Thus, maintenance works of the common facilities must be well organised. The purpose of this paper ...

  8. A Global Perspective on Drinking-Water and Sanitation Classification: An Evaluation of Census Content.

    Science.gov (United States)

    Yu, Weiyu; Wardrop, Nicola A; Bain, Robert E S; Lin, Yanzhao; Zhang, Ce; Wright, Jim A

    2016-01-01

    Following the recent expiry of the United Nations' 2015 Millennium Development Goals (MDGs), new international development agenda covering 2030 water, sanitation and hygiene (WASH) targets have been proposed, which imply new demands on data sources for monitoring relevant progress. This study evaluates drinking-water and sanitation classification systems from national census questionnaire content, based upon the most recent international policy changes, to examine national population census's ability to capture drinking-water and sanitation availability, safety, accessibility, and sustainability. In total, 247 censuses from 83 low income and lower-middle income countries were assessed using a scoring system, intended to assess harmonised water supply and sanitation classification systems for each census relative to the typology needed to monitor the proposed post-2015 indicators of WASH targets. The results signal a lack of international harmonisation and standardisation in census categorisation systems, especially concerning safety, accessibility, and sustainability of services in current census content. This suggests further refinements and harmonisation of future census content may be necessary to reflect ambitions for post-2015 monitoring.

  9. Visual classification of very fine-grained sediments: Evaluation through univariate and multivariate statistics

    Science.gov (United States)

    Hohn, M. Ed; Nuhfer, E.B.; Vinopal, R.J.; Klanderman, D.S.

    1980-01-01

    Classifying very fine-grained rocks through fabric elements provides information about depositional environments, but is subject to the biases of visual taxonomy. To evaluate the statistical significance of an empirical classification of very fine-grained rocks, samples from Devonian shales in four cored wells in West Virginia and Virginia were measured for 15 variables: quartz, illite, pyrite and expandable clays determined by X-ray diffraction; total sulfur, organic content, inorganic carbon, matrix density, bulk density, porosity, silt, as well as density, sonic travel time, resistivity, and ??-ray response measured from well logs. The four lithologic types comprised: (1) sharply banded shale, (2) thinly laminated shale, (3) lenticularly laminated shale, and (4) nonbanded shale. Univariate and multivariate analyses of variance showed that the lithologic classification reflects significant differences for the variables measured, difference that can be detected independently of stratigraphic effects. Little-known statistical methods found useful in this work included: the multivariate analysis of variance with more than one effect, simultaneous plotting of samples and variables on canonical variates, and the use of parametric ANOVA and MANOVA on ranked data. ?? 1980 Plenum Publishing Corporation.

  10. Evaluation of Effectiveness of Wavelet Based Denoising Schemes Using ANN and SVM for Bearing Condition Classification

    Directory of Open Access Journals (Sweden)

    Vijay G. S.

    2012-01-01

    Full Text Available The wavelet based denoising has proven its ability to denoise the bearing vibration signals by improving the signal-to-noise ratio (SNR and reducing the root-mean-square error (RMSE. In this paper seven wavelet based denoising schemes have been evaluated based on the performance of the Artificial Neural Network (ANN and the Support Vector Machine (SVM, for the bearing condition classification. The work consists of two parts, the first part in which a synthetic signal simulating the defective bearing vibration signal with Gaussian noise was subjected to these denoising schemes. The best scheme based on the SNR and the RMSE was identified. In the second part, the vibration signals collected from a customized Rolling Element Bearing (REB test rig for four bearing conditions were subjected to these denoising schemes. Several time and frequency domain features were extracted from the denoised signals, out of which a few sensitive features were selected using the Fisher’s Criterion (FC. Extracted features were used to train and test the ANN and the SVM. The best denoising scheme identified, based on the classification performances of the ANN and the SVM, was found to be the same as the one obtained using the synthetic signal.

  11. CBM Resources/reserves classification and evaluation based on PRMS rules

    Science.gov (United States)

    Fa, Guifang; Yuan, Ruie; Wang, Zuoqian; Lan, Jun; Zhao, Jian; Xia, Mingjun; Cai, Dechao; Yi, Yanjing

    2018-02-01

    This paper introduces a set of definitions and classification requirements for coalbed methane (CBM) resources/reserves, based on Petroleum Resources Management System (PRMS). The basic CBM classification criterions of 1P, 2P, 3P and contingent resources are put forward from the following aspects: ownership, project maturity, drilling requirements, testing requirements, economic requirements, infrastructure and market, timing of production and development, and so on. The volumetric method is used to evaluate the OGIP, with focuses on analyses of key parameters and principles of the parameter selection, such as net thickness, ash and water content, coal rank and composition, coal density, cleat volume and saturation and absorbed gas content etc. A dynamic method is used to assess the reserves and recovery efficiency. Since the differences in rock and fluid properties, displacement mechanism, completion and operating practices and wellbore type resulted in different production curve characteristics, the factors affecting production behavior, the dewatering period, pressure build-up and interference effects were analyzed. The conclusion and results that the paper achieved can be used as important references for reasonable assessment of CBM resources/reserves.

  12. Evaluation of soft segment modeling on a context independent phoneme classification system

    International Nuclear Information System (INIS)

    Razzazi, F.; Sayadiyan, A.

    2007-01-01

    The geometric distribution of states duration is one of the main performance limiting assumptions of hidden Markov modeling of speech signals. Stochastic segment models, generally, and segmental HMM, specifically overcome this deficiency partly at the cost of more complexity in both training and recognition phases. In addition to this assumption, the gradual temporal changes of speech statistics has not been modeled in HMM. In this paper, a new duration modeling approach is presented. The main idea of the model is to consider the effect of adjacent segments on the probability density function estimation and evaluation of each acoustic segment. This idea not only makes the model robust against segmentation errors, but also it models gradual change from one segment to the next one with a minimum set of parameters. The proposed idea is analytically formulated and tested on a TIMIT based context independent phenomena classification system. During the test procedure, the phoneme classification of different phoneme classes was performed by applying various proposed recognition algorithms. The system was optimized and the results have been compared with a continuous density hidden Markov model (CDHMM) with similar computational complexity. The results show 8-10% improvement in phoneme recognition rate in comparison with standard continuous density hidden Markov model. This indicates improved compatibility of the proposed model with the speech nature. (author)

  13. A Global Perspective on Drinking-Water and Sanitation Classification: An Evaluation of Census Content.

    Directory of Open Access Journals (Sweden)

    Weiyu Yu

    Full Text Available Following the recent expiry of the United Nations' 2015 Millennium Development Goals (MDGs, new international development agenda covering 2030 water, sanitation and hygiene (WASH targets have been proposed, which imply new demands on data sources for monitoring relevant progress. This study evaluates drinking-water and sanitation classification systems from national census questionnaire content, based upon the most recent international policy changes, to examine national population census's ability to capture drinking-water and sanitation availability, safety, accessibility, and sustainability. In total, 247 censuses from 83 low income and lower-middle income countries were assessed using a scoring system, intended to assess harmonised water supply and sanitation classification systems for each census relative to the typology needed to monitor the proposed post-2015 indicators of WASH targets. The results signal a lack of international harmonisation and standardisation in census categorisation systems, especially concerning safety, accessibility, and sustainability of services in current census content. This suggests further refinements and harmonisation of future census content may be necessary to reflect ambitions for post-2015 monitoring.

  14. A model for evaluating the environmental benefits of elementary school facilities.

    Science.gov (United States)

    Ji, Changyoon; Hong, Taehoon; Jeong, Kwangbok; Leigh, Seung-Bok

    2014-01-01

    In this study, a model that is capable of evaluating the environmental benefits of a new elementary school facility was developed. The model is composed of three steps: (i) retrieval of elementary school facilities having similar characteristics as the new elementary school facility using case-based reasoning; (ii) creation of energy consumption and material data for the benchmark elementary school facility using the retrieved similar elementary school facilities; and (iii) evaluation of the environmental benefits of the new elementary school facility by assessing and comparing the environmental impact of the new and created benchmark elementary school facility using life cycle assessment. The developed model can present the environmental benefits of a new elementary school facility in terms of monetary values using Environmental Priority Strategy 2000, a damage-oriented life cycle impact assessment method. The developed model can be used for the following: (i) as criteria for a green-building rating system; (ii) as criteria for setting the support plan and size, such as the government's incentives for promoting green-building projects; and (iii) as criteria for determining the feasibility of green building projects in key business sectors. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Impacts of transportation on a test and evaluation facility for nuclear waste disposal: a systems analysis

    International Nuclear Information System (INIS)

    Varadarajan, R.V.; Peterson, R.W.; Joy, D.S.; Gibson, S.M.

    1983-01-01

    An essential element of the Test and Evaluation Facility (TEF) is a waste packaging facility capable of producing a small number Test and Evaluation Facility of packages consisting of several different waste forms. The study envisions three scenarios for such a packaging facility: (1) modify an existing hot cell facility such as the Engine Maintenance Assembly and Disassembly (EMAD) facility at the Nevada Test Site so that it can serve as a packaging facility for the TEF. This scenario is referred to as the EMAD Option. (2) Build a new generic packaging facility (GPF) at the site of the TEF. In other words, colocate the GPF and the TEF. This scenario is referred to as the GPF Option, and (3) utilize the EMAD facility in conjunction with a colocated GPF (of minimal size and scope) at the TEF. This scenario is referred to as the Split Option. The results of the system study clearly bring out the fact that transportation has a significant impact on the selection and siting of the waste packaging facility. Preliminary conclusions, subject to the assumptions of the study, include the following: (1) regardless of the waste form, the GPF option is preferable to the other two in minimizing both transportation costs and logistical problems, (2) for any given scenario and choice of waste forms, there exists a candidate TEF location for which the transportation costs are at a minimum compared to the other locations, (3) in spite of the increased transportation costs and logistical complexity, the study shows that the overall system costs favor modification of an existing hot cell facility for the particular case considered

  16. Evaluation of Geopolymer Concrete for Rocket Test Facility Flame Deflectors

    Science.gov (United States)

    Allgood, Daniel C.; Montes, Carlos; Islam, Rashedul; Allouche, Erez

    2014-01-01

    The current paper presents results from a combined research effort by Louisiana Tech University (LTU) and NASA Stennis Space Center (SSC) to develop a new alumina-silicate based cementitious binder capable of acting as a high performance refractory material with low heat ablation rate and high early mechanical strength. Such a binder would represent a significant contribution to NASA's efforts to develop a new generation of refractory 'hot face' liners for liquid or solid rocket plume environments. This project was developed as a continuation of on-going collaborations between LTU and SSC, where test sections of a formulation of high temperature geopolymer binder were cast in the floor and walls of Test Stand E-1 Cell 3, an active rocket engine test stand flame trench. Additionally, geopolymer concrete panels were tested using the NASA-SSC Diagnostic Test Facility (DTF) thruster, where supersonic plume environments were generated on a 1ft wide x 2ft long x 6 inch deep refractory panel. The DTF operates on LOX/GH2 propellants producing a nominal thrust of 1,200 lbf and the combustion chamber conditions are Pc=625psig, O/F=6.0. Data collected included high speed video of plume/panel area and surface profiles (depth) of the test panels measured on a 1-inch by 1-inch giving localized erosion rates during the test. Louisiana Tech conducted a microstructure analysis of the geopolymer binder after the testing program to identify phase changes in the material.

  17. Evaluation of the CDTN's cementation facility using the results obtained in two different sizes: laboratory and facility

    International Nuclear Information System (INIS)

    Haucz, Maria Judite A.; Calabria, Jaqueline A. Almeida; Tello, Cledola Cassia O.; Candido, Francisco Donizete; Seles, Sandro Rogerio Novaes

    2011-01-01

    At CDTN R and D activities generate low-level radioactive wastes, among them the aqueous liquid ones, which need special attention due to their volumes. The usual treatment for these wastes is the volume reduction process using chemicals in order to change the radionuclides of the waste to an insoluble form. The resultant sludge is incorporated into cement in 200-liter drums using an in-line batch mixing system (CDTN Cementation Facility). The process parameters and solidified product quality are evaluated at the Cementation Laboratory (LABCIM), where tests are carried out to determine the viscosity, set time and density of the paste. In addition of the visual examination, compressive strength test and density are also established in the solidified product. In the cementation facility some pastes are also prepared for the immobilization of non-compactable waste, such as dump, scrap metal, wood, and other ones. This paper aims to present the study comparing the results of tests done in the pastes and products prepared in LABCIM and the ones obtained in CDTN's cementation facility, in order to check the efficiency of the cementation system. (author)

  18. Evaluation of the CDTN cementation facility using the results obtained in two different sizes: laboratory and facility

    International Nuclear Information System (INIS)

    Haucz, Maria Judite A.; Calabria, Jaqueline A. Almeida; Tello, Cledola Cassia O.; Candido, Francisco Donizete; Seles, Sandro Rogerio Novaes

    2011-01-01

    At CDTN R and D activities generate low-level radioactive wastes, among them the aqueous liquid ones, which need special attention due to their volumes. The usual treatment for these wastes is the volume reduction process using chemicals in order to change the radionuclides of the waste to an insoluble form. The resultant sludge is incorporated into cement in 200-liter drums using an in-line batch mixing system (CDTN Cementation Facility). The process parameters and solidified product quality are evaluated at the Cementation Laboratory (LABCIM), where tests are carried out to determine the viscosity, set time and density of the paste. In addition of the visual examination, compressive strength test and density are also established in the solidified product. In the cementation facility some pastes are also prepared for the immobilization of non-compactable waste, such as dump, scrap metal, wood, and other ones. This paper aims to present the study comparing the results of tests done in the pastes and products prepared in LABCIM and the ones obtained in CDTN's cementation facility, in order to check the efficiency of the cementation system. (author)

  19. Engineering evaluation/cost analysis for the 233-S Plutonium Concentration Facility

    International Nuclear Information System (INIS)

    1997-01-01

    The deactivated 233-S Plutonium Concentration Facility (233-S Facility) is located in the 200 Area. The facility has undergone severe degradation due to exposure to extreme weather conditions. A rapid freeze and thaw cycle occurred at the Hanford Site during February 1996, which caused cracking to occur on portions of the building's roof. This has resulted in significantly infiltration of water into the facility, which provides a pathway for potential release of radioactive material into the environment (air and/or ground). The weather caused several existing cracks in the concrete portions of the structure to lengthen, increasing the potential for failed confinement of the radioactive material in the building. Differential settlement has also occurred, causing portions of the facility to separate from the main building structure thus creating a potential for release of radioactive material t the environment. An expedited removal action is proposed to ensure that a release from the 233-S Facility does not occur. The US Department of Energy (DOE), Richland Operations Office (RL), in cooperation with the EPA, has prepared this Engineering Evaluation/Cost Analysis (EE/CA) pursuant to CERCLA. Based on the evaluation, RL has determined that hazardous substances in the 233-S Facility may present a potential threat to human health and/or the environment, and that an expedited removal action is warranted. The purpose of the EE/CA is to provide the framework for the evaluation and selection of a technology from a viable set of alternatives for a removal action

  20. Review Article : Utilization of Environmental Radiochemistry Techniques for Selection and Evaluation of Nuclear Facility Sites

    International Nuclear Information System (INIS)

    Atta, E.R.; Madbouly, A.M.; Zakaria, Kh.M.

    2016-01-01

    This research review puts necessary considerations on the available environmental radiochemistry techniques for selection and evaluation of a nuclear facility sites.The main bjective in site evaluation for nuclear facilities in terms of nuclear safety is to protect the site workers, the public and the environment from the effects of ionizing radiation release from nuclear facilities due to accidents. The extreme sensitivity and speed of radiochemical methods make their applications of considerable importance in several fields and they have found many uses. Information about the existed radioactivity in the different nuclear facilities is an essential requirement for their environmental assessment. It is necessary to estimate the various radioactivity levels in the environment through qualitative and quantitative analytical techniques and to assess the potential effects of the nuclear facility in the region by considering the characteristics of sites.The siting and site evaluation requirements are discussed. Emphasis was given to types of radiochemical techniques used for characterization of the site parameters which determine the potential hazards of the site on the facility and the facility on the site. Emphasis has been also given to the quantitative and qualitative analysis of naturally occurring radionuclides for monitoring and control .There are some techniques employed such as radioactive tracer technique, liquid scintillation technique, gamma spectrometry technique, neutron activation analysis technique, fluorimetric technique and isotope hydrology technique.

  1. Criticality safety evaluation of the fuel cycle facility electrorefiner

    International Nuclear Information System (INIS)

    Lell, R.M.; Mariani, R.D.; Fujita, E.K.; Benedict, R.W.; Turski, R.B.

    1993-01-01

    The integral Fast Reactor (IFR) being developed by Argonne National Laboratory (ANL) combines the advantages of metal-fueled, liquid-metal cooled reactors and a closed-loop fuel cycle. Some of the primary advantages are passive safety for the reactor and resistance to diversion for the heavy metal in the fuel cycle. in addition, the IFR pyroprocess recycles all the long-lived actinide activation products for casting into new fuel pins so that they may be burned in the reactor. A key component in the Fuel Cycle Facility (FCF) recycling process is the electrorefiner (ER) in which the actinides are separated from the fission products. In the process, the metal fuel is electrochemically dissolved into a high-temperature molten salt, and electrorefined uranium or uranium/plutonium products are deposited at cathodes. This report addresses the new and innovative aspects of the criticality analysis ensuing from processing metallic fuel, rather than metal oxide fuel, and from processing the spent fuel in batch operations. in particular, the criticality analysis employed a mechanistic approach as opposed to a probabilistic one. A probabilistic approach was unsuitable because of a lack of operational experience with some of the processes, rendering the estimation of accident event risk factors difficult. The criticality analysis also incorporated the uncertainties in heavy metal content attending the process items by defining normal operations envelopes (NOES) for key process parameters. The goal was to show that reasonable process uncertainties would be demonstrably safe toward criticality for continuous batch operations provided the key process parameters stayed within their NOES. Consequently the NOEs became the point of departure for accident events in the criticality analysis

  2. BP network for atorvastatin effect evaluation from ultrasound images features classification

    Science.gov (United States)

    Fang, Mengjie; Yang, Xin; Liu, Yang; Xu, Hongwei; Liang, Huageng; Wang, Yujie; Ding, Mingyue

    2013-10-01

    Atherosclerotic lesions at the carotid artery are a major cause of emboli or atheromatous debris, resulting in approximately 88% of ischemic strokes in the USA in 2006. Stroke is becoming the most common cause of death worldwide, although patient management and prevention strategies have reduced stroke rate considerably over the past decades. Many research studies have been carried out on how to quantitatively evaluate local arterial effects for potential carotid disease treatments. As an inexpensive, convenient and fast means of detection, ultrasonic medical testing has been widespread in the world, so it is very practical to use ultrasound technology in the prevention and treatment of carotid atherosclerosis. This paper is dedicated to this field. Currently, many ultrasound image characteristics on carotid plaque have been proposed. After screening a large number of features (including 26 morphological and 85 texture features), we have got six shape characteristics and six texture characteristics in the combination. In order to test the validity and accuracy of these combined features, we have established a Back-Propagation (BP) neural network to classify atherosclerosis plaques between atorvastatin group and placebo group. The leave-one-case-out protocol was utilized on a database of 768 carotid ultrasound images of 12 patients (5 subjects of placebo group and 7 subjects of atorvastatin group) for the evaluation. The classification results showed that the combined features and classification have good recognition ability, with the overall accuracy 83.93%, sensitivity 82.14%, specificity 85.20%, positive predictive value 79.86%, negative predictive value 86.98%, Matthew's correlation coefficient 67.08%, and Youden's index 67.34%. And the receiver operating characteristic (ROC) curve in our test also performed well.

  3. Economic evaluation method of new facilities for uranium ore processing

    International Nuclear Information System (INIS)

    Hebert, J.P.

    1986-01-01

    The importance of economic evaluation in feasibility studies is underlined. Notions of discounting are recalled. Profits of a project are analyzed. Studies can be relatively simple for a first estimation if investment cost and production cost are available because profits of a new production unit or savings obtained by a new investment are determined. But for integrated projects mine-plant the studies are complex especially for complete exploitation account [fr

  4. Emergency preparedness exercises for nuclear facilities: Preparation, conduct and evaluation

    International Nuclear Information System (INIS)

    1985-01-01

    This publication offers guidance for operating organizations and public authorities on planning, organizing and conducting exercises, preparing scenarios and evaluating the results of exercises in order to make full use of the experience gained in improving the response planning and preparedness for radiation emergencies. The training aspects associated with achieving an adequate level of emergency preparedness are explored and examples of accident scenarios are presented

  5. Engineering evaluation/cost analysis for the 233-S Plutonium Concentration Facility

    International Nuclear Information System (INIS)

    Rugg, J.E.

    1996-08-01

    The 100, 200, 300 and 1100 Areas of the Hanford Site were placed on the U. S. Environmental Protection Agency's National Priorities List in November 1989 under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). Located in the 200 Area is the deactivated 233-S Plutonium Concentration Facility (used in the REDOX process). The facility has undergone severe degradation due to exposure to extreme weather conditions. An expedited response is proposed to ensure protection of human health and the environment. The Department of Energy, Richland Operations Office (RL) in cooperation with the Washington State Department of Ecology, has prepared this Engineering Evaluation/Cost Analysis pursuant to CERCLA. Based on the evaluation, RL has determined that hazardous substances in the 233-S Facility may present a potential threat to human health or the environment, and that an expedited removal action is warranted for decommissioning of the facility

  6. Environmental, economic, and energy impacts of material recovery facilities. A MITE Program evaluation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    This report documents an evaluation of the environmental, economic, and energy impacts of material recovery facilities (MRFs) conducted under the Municipal Solid Waste Innovative Technology Evaluation (MITE) Program. The MITE Program is sponsored by the US Environmental Protection Agency to foster the demonstration and development of innovative technologies for the management of municipal solid waste (MSW). This project was also funded by the National Renewable Energy Laboratory (NREL). Material recovery facilities are increasingly being used as one option for managing a significant portion of municipal solid waste (MSW). The owners and operators of these facilities employ a combination of manual and mechanical techniques to separate and sort the recyclable fraction of MSW and to transport the separated materials to recycling facilities.

  7. Application of dose evaluation of the MCNP code for interim spent fuel cask storage facility

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Iimoto, Takeshi; Ishikawa, Satoshi; Tsuboi, Takafumi; Teramura, Masahiro; Okamura, Tomomi; Narumiya, Yoshiyuki

    2007-01-01

    The interim storage facility for spent fuel metallic cask is designed as a concrete building structure with air inlet and outlet for circulating the natural cooling. The feature of the interim storage facility is big capacity of spent fuel at several thousands MTU and restricted site usage. It is important to evaluate realistic dose rate in shielding design of the interim storage facility, therefore the three-dimensional continuous-energy Monte Carlo radiation transport code MCNP that exactly treating the complicated geometry was applied. The validation of dose evaluation for interim storage facility by MCNP code were performed by three kinds of neutron shielding benchmark experiments; cask shadow shielding experiment, duct streaming experiment and concrete deep penetration experiment. Dose rate distributions at each benchmark were measured and compared with the calculated results. The comparison showed a good consistency between calculation and experiment results. (author)

  8. performance-based approach to design and evaluation of nuclear security systems for Brazilian nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, Renato L. A.; Filho, Josélio S. M., E-mail: renato.tavares@cnen.gov.br, E-mail: joselio@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear. Divisão de Normas e Segurança Física; Fontes, Gladson S.; Fiel, J.C.B., E-mail: gsfontes@hotmail.com, E-mail: fiel@ime.eb.br [Instituto Militar de Engenharia (SE-7/IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    This study presents an application of a performance-based approach to definition of requirements, design and evaluation of physical protection systems for nuclear facilities. Such approach considers a probabilistic analysis of the threat, equipment, systems and response forces used to prevent, dissuade and detain malicious acts against the integrity of facilities and the nuclear materials inside them. Nowadays, in the context of Brazilian nuclear facilities licensing, a mostly prescriptive approach is adopted, which despite having advantages such as simplified inspections and homogeneous regulatory requisites amid different fuel cycle facility types, does not consider evolution, dynamism and capacities of external or internal threats to facilities and to Brazilian Nuclear Program itself, neither provides metrics to evaluate system performance facing such threats. In order to preserve actual plans and systems confidentiality, a facility hypothetical model is created, including a research reactor and a waste storage facility. It is expected that the methodology and results obtained in this study serve in the future as a basis to Brazilian nuclear operators, in elaboration process of their Physical Protection Plans, which must comply with future regulation CNEN-NN 2.01, a revision of CNEN-NE 2.01, once that regulation will include performance requisites. (author)

  9. performance-based approach to design and evaluation of nuclear security systems for Brazilian nuclear facilities

    International Nuclear Information System (INIS)

    Tavares, Renato L. A.; Filho, Josélio S. M.; Fontes, Gladson S.; Fiel, J.C.B.

    2017-01-01

    This study presents an application of a performance-based approach to definition of requirements, design and evaluation of physical protection systems for nuclear facilities. Such approach considers a probabilistic analysis of the threat, equipment, systems and response forces used to prevent, dissuade and detain malicious acts against the integrity of facilities and the nuclear materials inside them. Nowadays, in the context of Brazilian nuclear facilities licensing, a mostly prescriptive approach is adopted, which despite having advantages such as simplified inspections and homogeneous regulatory requisites amid different fuel cycle facility types, does not consider evolution, dynamism and capacities of external or internal threats to facilities and to Brazilian Nuclear Program itself, neither provides metrics to evaluate system performance facing such threats. In order to preserve actual plans and systems confidentiality, a facility hypothetical model is created, including a research reactor and a waste storage facility. It is expected that the methodology and results obtained in this study serve in the future as a basis to Brazilian nuclear operators, in elaboration process of their Physical Protection Plans, which must comply with future regulation CNEN-NN 2.01, a revision of CNEN-NE 2.01, once that regulation will include performance requisites. (author)

  10. Progress towards developing consistent design and evaluation guidelines for DOE facilities subjected to natural phenomena hazards

    International Nuclear Information System (INIS)

    Kennedy, R.P.; Short, S.A.; McDonald, J.R.; McCann, M.W. Jr.; Reed, J.W.

    1985-01-01

    Probabilistic definitions of earthquake, wind and tornado natural phenomena hazards for many Department of Energy (DOE) facilities throughout the United States have been developed. In addition, definitions of the flood hazards which might affect these locations are currently being developed. The Department of Energy Natural Phenomena Hazards Panel is now preparing a document to provide guidance and criteria for DOE facility managers to assure that DOE facilities are adequately constructed to resist the effects of natural phenomena such as earthquake, strong wind and flood. The intent of this document is to provide instruction on how to utilize the hazard definitions to evaluate existing facilities and design new facilities in a manner such that the risk of adverse consequences is consistent with the cost, function, and danger to the public or environment of the facility. Potential effects on facilities of natural phenomena hazards are emphasized in this paper. The philosophy for mitigating these effects to be employed in the design and evaluation guidelines is also presented

  11. A probabilistic risk assessment of the LLNL Plutonium Facility's evaluation basis fire operational accident. Revision 1

    International Nuclear Information System (INIS)

    Brumburgh, G.P.

    1995-01-01

    The Lawrence Livermore National Laboratory (LLNL) Plutonium Facility conducts numerous programmatic activities involving plutonium to include device fabrication, development of improved and/or unique fabrication techniques, metallurgy research, and laser isotope separation. A Safety Analysis Report (SAR) for the building 332 Plutonium Facility was completed in July 1994 to address operational safety and acceptable risk to employees, the public, government property, and the environmental. This paper outlines the PRA analysis of the Evaluation Basis Fire (EBF) operational accident. The EBF postulates the worst-case programmatic impact event for the Plutonium Facility

  12. Polyp morphology: an interobserver evaluation for the Paris classification among international experts.

    Science.gov (United States)

    van Doorn, Sascha C; Hazewinkel, Y; East, James E; van Leerdam, Monique E; Rastogi, Amit; Pellisé, Maria; Sanduleanu-Dascalescu, Silvia; Bastiaansen, Barbara A J; Fockens, Paul; Dekker, Evelien

    2015-01-01

    The Paris classification is an international classification system for describing polyp morphology. Thus far, the validity and reproducibility of this classification have not been assessed. We aimed to determine the interobserver agreement for the Paris classification among seven Western expert endoscopists. A total of 85 short endoscopic video clips depicting polyps were created and assessed by seven expert endoscopists according to the Paris classification. After a digital training module, the same 85 polyps were assessed again. We calculated the interobserver agreement with a Fleiss kappa and as the proportion of pairwise agreement. The interobserver agreement of the Paris classification among seven experts was moderate with a Fleiss kappa of 0.42 and a mean pairwise agreement of 67%. The proportion of lesions assessed as "flat" by the experts ranged between 13 and 40% (Pagreement did not change (kappa 0.38, pairwise agreement 60%). Our study is the first to validate the Paris classification for polyp morphology. We demonstrated only a moderate interobserver agreement among international Western experts for this classification system. Our data suggest that, in its current version, the use of this classification system in daily practice is questionable and it is unsuitable for comparative endoscopic research. We therefore suggest introduction of a simplification of the classification system.

  13. 105-DR Large sodium fire facility soil sampling data evaluation report

    International Nuclear Information System (INIS)

    Adler, J.G.

    1996-01-01

    This report evaluates the soil sampling activities, soil sample analysis, and soil sample data associated with the closure activities at the 105-DR Large Sodium Fire Facility. The evaluation compares these activities to the regulatory requirements for meeting clean closure. The report concludes that there is no soil contamination from the waste treatment activities

  14. Ground test facilities for evaluating nuclear thermal propulsion engines and fuel elements

    International Nuclear Information System (INIS)

    Allen, G.C.; Beck, D.F.; Harmon, C.D.; Shipers, L.R.

    1992-01-01

    Interagency panels evaluating nuclear thermal propulsion development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and design issues of a proposed ground test complex for evaluating nuclear thermal propulsion engines and fuel elements being developed for the Space Nuclear Thermal Propulsion (SNTP) program. 2 refs

  15. Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities

    International Nuclear Information System (INIS)

    1993-11-01

    This document contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE non-reactor nuclear facilities. Adherence to these guidelines will provide consistency and uniformity in criticality safety evaluations (CSEs) across the complex and will document compliance with the requirements of DOE Order 5480.24

  16. Introduction to the nuclear criticality safety evaluation of facility X-705, Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Sheaffer, M.K.; Keeton, S.C.

    1993-01-01

    This report is the first in a series of documents that will evaluate nuclear criticality safety in the Decontamination and Recovery Facility, X-705, Portsmouth Gaseous Diffusion Plant. It provides an overview of the facility, categorizes its functions for future analysis, reviews existing NCS documentation, and explains the follow-on effort planned for X-705. A detailed breakdown of systems, subsystems, and operational areas is presented and cross-referenced to existing NCS documentation

  17. Hydrology model evaluation at the Hanford Nuclear Waste Facility

    International Nuclear Information System (INIS)

    1977-04-01

    One and two-dimensional flow and contaminant transport computer models have been developed at Hanford to assess the rate and direction of contaminant movement from waste disposal sites. The primary objective of this work was to evaluate the potential improvement in accuracy that a three-dimensional model might offer over the simpler one and two-dimensional models. INTERA's hydrology contaminant transport model was used for this evaluation. Although this study was conceptual in nature, an attempt was made to relate it as closely as possible to Hanford conditions. Two-dimensional model runs were performed over the period of 1968 to 1973 using estimates of waste discharge flows, tritium concentrations, vertically averaged values of aquifer properties and boundary conditions. The well test interpretation runs confirmed the applicability of the areal hydraulic conductivity distribution. Velocity fields calculated by the two-dimensional and three-dimensional models and surface concentration profiles calculated by the two-dimensional and three-dimensional models show significant differences. Vertical concentration profiles calculated by a three-dimensional model show better qualitative agreement with the limited observed concentration profile data supplied by ARHCO

  18. Natural phenomena hazards design and evaluation criteria for Department of Energy Facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-01

    The Department of Energy (DOE) has issued an Order 420.1 which establishes policy for its facilities in the event of natural phenomena hazards (NPH) along with associated NPH mitigation requirements. This DOE Standard gives design and evaluation criteria for NPH effects as guidance for implementing the NPH mitigation requirements of DOE Order 420.1 and the associated implementation Guides. These are intended to be consistent design and evaluation criteria for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of these criteria is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. These criteria apply to the design of new facilities and the evaluation of existing facilities. They may also be used for modification and upgrading of existing facilities as appropriate. The design and evaluation criteria presented herein control the level of conservatism introduced in the design/evaluation process such that earthquake, wind, and flood hazards are treated on a consistent basis. These criteria also employ a graded approach to ensure that the level of conservatism and rigor in design/evaluation is appropriate for facility characteristics such as importance, hazards to people on and off site, and threat to the environment. For each natural phenomena hazard covered, these criteria consist of the following: Performance Categories and target performance goals as specified in the DOE Order 420.1 NPH Implementation Guide, and DOE-STD-1 021; specified probability levels from which natural phenomena hazard loading on structures, equipment, and systems is developed; and design and evaluation procedures to evaluate response to NPH loads and criteria to assess whether or not computed response is permissible.

  19. Nerva fuel nondestructive evaluation and characterization equipment and facilities

    International Nuclear Information System (INIS)

    Caputo, A.J.

    1993-01-01

    Nuclear Thermal Propulsion (NTP) is one of the technologies that the Space Exploration Initiative (SEI) has identified as essential for a manned mission to Mars. A base or prior work is available upon which to build in the development of nuclear rockets. From 1955 to 1973, the U.S Atomic Energy Commission (AEC) sponsored development and testing of a nuclear rocket engine under Project Rover. The rocket engine, called the Nuclear Engine for Rocket Vehicle Application (NERVA), used a graphite fuel element incorporating coated particle fuel. Much of the NERVA development and manufacturing work was performed at the Oak Ridge Y-12 Plant. This paper gives a general review of that work in the area of nondestructive evaluation and characterization. Emphasis is placed on two key characteristics: uranium content and distribution and thickness profile of metal carbide coatings deposited in the gas passage holes

  20. Prioritization of natural phenomena hazards evaluations for CHG facilities

    International Nuclear Information System (INIS)

    GRAVES, C.E.

    2001-01-01

    Natural phenomena hazards (NPH) are unexpected acts of nature that pose a threat or danger to workers, the public or to the environment by potential damage to structures, systems and components (SSCs). Earthquakes, extreme winds (hurricane and tornado), flood, volcanic eruption, lightning strike, or extreme cold or heat are examples of NPH. This document outlines the method used to prioritize buildings for inspection following an NPH event and contains the priority list for CH2M HILL Hanford Group, Inc. (CHG) buildings. Once an NPH event occurs and the Hanford Emergency Operations Center (EOC) is activated, this document will be used by the EOC to assign building inspections for the trained evaluators, barring any information from the field

  1. Prioritization of natural phenomena hazards evaluations for CHG facilities

    CERN Document Server

    Graves, C E

    2001-01-01

    Natural phenomena hazards (NPH) are unexpected acts of nature that pose a threat or danger to workers, the public or to the environment by potential damage to structures, systems and components (SSCs). Earthquakes, extreme winds (hurricane and tornado), flood, volcanic eruption, lightning strike, or extreme cold or heat are examples of NPH. This document outlines the method used to prioritize buildings for inspection following an NPH event and contains the priority list for CH2M HILL Hanford Group, Inc. (CHG) buildings. Once an NPH event occurs and the Hanford Emergency Operations Center (EOC) is activated, this document will be used by the EOC to assign building inspections for the trained evaluators, barring any information from the field.

  2. Development of a standardized transfusion ratio as a metric for evaluating dialysis facility anemia management practices.

    Science.gov (United States)

    Liu, Jiannong; Li, Suying; Gilbertson, David T; Monda, Keri L; Bradbury, Brian D; Collins, Allan J

    2014-10-01

    Because transfusion avoidance has been the cornerstone of anemia treatment for patients with kidney disease, direct measurement of red blood cell transfusion use to assess dialysis facility anemia management performance is reasonable. We aimed to explore methods for estimating facility-level standardized transfusion ratios (STfRs) to assess provider anemia treatment practices. Retrospective cohort study. Point prevalent US hemodialysis patients on January 1, 2009, with Medicare as primary payer and dialysis duration of 90 days or longer were included (n = 223,901). All dialysis facilities with eligible patients were included (n = 5,345). Dialysis facility assignment. Receiving a red blood cell transfusion in the inpatient or outpatient setting. We evaluated 3 approaches for estimating STfR: ratio of observed to expected numbers of transfusions (STfR(obs)), a Bayesian approach (STfR(Bayes)), and a modified version of the Bayesian approach (STfR(modBayes)). The overall national transfusion rate in 2009 was 23.2 per 100 patient-years. Our model for predicting the expected number of transfusions performed well. For large facilities, all 3 STfRs worked well. However, for small facilities, while the STfR(modBayes) worked well, STfR(obs) values demonstrated instability and the STfR(Bayes) may produce more bias. Administration of transfusions to dialysis patients reflects medical practice both within and outside the dialysis unit. Some transfusions may be deemed unavoidable and transfusion practices are subject to considerable regional variation. Development of an STfR metric is feasible and reasonable for assessing anemia treatment at dialysis facilities. The STfR(obs) is simple to calculate and works well for larger dialysis facilities. The STfR(modBayes) is more analytically complex, but facilitates comparisons across all dialysis facilities, including small facilities. Copyright © 2014 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  3. An Evaluation Model for Tailings Storage Facilities Using Improved Neural Networks and Fuzzy Mathematics

    Directory of Open Access Journals (Sweden)

    Sen Tian

    2014-01-01

    Full Text Available With the development of mine industry, tailings storage facility (TSF, as the important facility of mining, has attracted increasing attention for its safety problems. However, the problems of low accuracy and slow operation rate often occur in current TSF safety evaluation models. This paper establishes a reasonable TSF safety evaluation index system and puts forward a new TSF safety evaluation model by combining the theories for the analytic hierarchy process (AHP and improved back-propagation (BP neural network algorithm. The varying proportions of cross validation were calculated, demonstrating that this method has better evaluation performance with higher learning efficiency and faster convergence speed and avoids the oscillation in the training process in traditional BP neural network method and other primary neural network methods. The entire analysis shows the combination of the two methods increases the accuracy and reliability of the safety evaluation, and it can be well applied in the TSF safety evaluation.

  4. Evaluation of radiological dispersion/consequence codes supporting DOE nuclear facility SARs

    International Nuclear Information System (INIS)

    O'Kula, K.R.; Paik, I.K.; Chung, D.Y.

    1996-01-01

    Since the early 1990s, the authorization basis documentation of many U.S. Department of Energy (DOE) nuclear facilities has been upgraded to comply with DOE orders and standards. In this process, many safety analyses have been revised. Unfortunately, there has been nonuniform application of software, and the most appropriate computer and engineering methodologies often are not applied. A DOE Accident Phenomenology and Consequence (APAC) Methodology Evaluation Program was originated at the request of DOE Defense Programs to evaluate the safety analysis methodologies used in nuclear facility authorization basis documentation and to define future cost-effective support and development initiatives. Six areas, including source term development (fire, spills, and explosion analysis), in-facility transport, and dispersion/ consequence analysis (chemical and radiological) are contained in the APAC program. The evaluation process, codes considered, key results, and recommendations for future model and software development of the Radiological Dispersion/Consequence Working Group are summarized in this paper

  5. Vocational rehabilitation evaluation and the International Classification of Functioning, Disability, and Health (ICF).

    Science.gov (United States)

    Saltychev, Mikhail; Kinnunen, Aila; Laimi, Katri

    2013-03-01

    To identify the most frequent functional limitations according to the International Classification of Functioning, Disability, and Health (ICF) obtained by unstandardised clinical assessment of patients with chronic musculoskeletal disorders who underwent vocational rehabilitation evaluation; and to compare the obtained list with simplified versions of ICF. The descriptions of functional limitations were retrospectively identified for 32 patients. The original vocational rehabilitation evaluation was conducted by a multi-professional team in an out-patient clinic of a university hospital. The obtained descriptions were converted to ICF codes, the most frequent being compared with the ICF Checklist of the World Health Organization (WHO) and the ICF Comprehensive and Brief Core Sets suggested by the ICF Research Branch. In the study population (53 % women), 141 ICF codes were identified with a preciseness of three or more digits, the average being 21 codes/subject (median 20.0, range 9-40). When truncated to three digits, 84 ICF codes remained (average 18 codes/subject, range 9-25), 45 of which appeared in over 10 % of the study population, 24 also being found in the ICF Comprehensive, 5 in the ICF Brief Core Sets, and 33 in the WHO ICF Checklist. The list of most frequent ICF codes retrospectively obtained in this study from unstandardised records showed a similarity with ICF Comprehensive and Brief Core Sets by ICF Research Branch and the ICF Checklist by WHO, but with a bias towards the identification of body structures and functions. The results support the use of ICF in vocational rehabilitation evaluation to ensure comprehensiveness of evaluation. The ICF Comprehensive Core Set seems to be the most useful for the needs of multiprofessional team when assessing functioning of patients.

  6. Classification of dual language audio-visual content: Introduction to the VideoCLEF 2008 pilot benchmark evaluation task

    NARCIS (Netherlands)

    Larson, M.; Newman, E.; Jones, G.J.F.; Köhler, J.; Larson, M.; de Jong, F.M.G.; Kraaij, W.; Ordelman, R.J.F.

    2008-01-01

    VideoCLEF is a new track for the CLEF 2008 campaign. This track aims to develop and evaluate tasks in analyzing multilingual video content. A pilot of a Vid2RSS task involving assigning thematic class labels to video kicks off the VideoCLEF track in 2008. Task participants deliver classification

  7. Performance assessment studies for the long-term safety evaluation of radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Bujoreanu, D.; Olteanu, M.; Bujoreanu, L.

    2008-01-01

    Especially during the last ten years, a part of Romanian research program 'Management of Radioactive Waste and Spent Fuel' was focused mainly on applicative research for the design of near-surface disposal facility, which intends to accommodate the low and intermediate radioactive waste generated from Cernavoda NPP. In this frame, our contribution was at the acquisition of technical data for the characterization of the future disposal facility. In the present, the project of the disposal facility, located on the Saligny site, near Cernavoda NPP, must be licensed. As regards to the safe disposal, the location of final disposal, the Saligny site, has been characterized through the five geological formations which contain potential routes for transport of radionuclide released from disposal facility, in the receiving zones(potential receiving zones), into liquid and gaseous phases. The technical characteristics of the disposal facility were adapted at the Romanian disposal concept using the reference data from IAEA technical report (IAEA,1999). Input parameters which characterized from physical and chemical point of view the disposal system, were partially taken from literature. The performance assessment studies, which follows the preliminary design development phases and the selection, describes how the source term is affected by the infiltration of water through the disposal facility, degradation process of engineering barriers (reflected in the distribution coefficient values) and solubility limit. The studies regard the evaluation of the source term, sensitivity and uncertainty analysis provide the information on 'how' and 'why' were evaluated, following: (i) radiological safety assessment of near-surface disposal facility on Saligny site; (ii) complexity standard assessment of the Engineering Barriers Systems (EBS); (iii) identification of the elements which must be elaborated for the increase of the disposal safety and the necessity for new technical data for

  8. Neutron transport calculation for Activation Evaluation for Decommissioning of PET cyclotron Facility

    Science.gov (United States)

    Nobuhara, Fumiyoshi; Kuroyanagi, Makoto; Masumoto, Kazuyoshi; Nakamura, Hajime; Toyoda, Akihiro; Takahashi, Katsuhiko

    2017-09-01

    In order to evaluate the state of activation in a cyclotron facility used for the radioisotope production of PET diagnostics, we measured the neutron flux by using gold foils and TLDs. Then, the spatial distribution of neutrons and induced activity inside the cyclotron vault were simulated with the Monte Calro calculation code for neutron transport and DCHAIN-SP for activation calculation. The calculated results are in good agreement with measured values within factor 3. Therefore, the adaption of the advanced evaluation procedure for activation level is proved to be important for the planning of decommissioning of these facilities.

  9. Use of the event tree method for evaluate the safety of radioactive facilities

    International Nuclear Information System (INIS)

    Hernandez S, A.; Cornejo D, N.; Callis F, E.

    2006-01-01

    The work shows the validity of the use of Trees of Events like a quantitative method appropriate to carry out evaluations of radiological safety. Its were took like base the evaluations of safety of five Radiotherapy Departments, carried out in the mark of the process of authorization of these facilities. The risk values were obtained by means of the combination of the probabilities of occurrence of the events with its consequences. The use of the method allowed to suggest improvements to the existent safety systems, as well as to confirm that the current regulator requirements for this type of facilities to lead to practices with acceptable risk levels. (Author)

  10. Evaluation of nuclear facility decommissioning projects. Status report. Humboldt Bay Power Plant Unit 3, SAFSTOR decommissioning

    International Nuclear Information System (INIS)

    Baumann, B.L.; Haffner, D.R.; Miller, R.L.; Scotti, K.S.

    1986-06-01

    This document explains the purpose of the US Nuclear Regulatory Commission's (NRC) Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program and summarizes information concerning the decommissioning of the Humboldt Bay Power Plant (HBPP) Unit 3 facility. Preparations to put this facility into a custodial safe storage (SAFSTOR) mode are currently scheduled for completion by June 30, 1986. This report gives the status of activities as of June 1985. A final summary report will be issued after completion of this SAFSTOR decommissioning activity. Information included in this status report has been collected from the facility decommissioning plan, environmental report, and other sources made available by the licensee. This data has been placed in a computerized data base system which permits data manipulation and summarization. A description of the computer reports that can be generated by the decommissioning data system (DDS) for Humboldt Bay and samples of those reports are included in this document

  11. Development and evaluation of fully automated demand response in large facilities

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Sezgen, Osman; Watson, David S.; Motegi, Naoya; Shockman, Christine; ten Hope, Laurie

    2004-03-30

    This report describes the results of a research project to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve electric grid reliability, manage electricity costs, and ensure that customers receive signals that encourage load reduction during times when the electric grid is near its capacity. The two main drivers for widespread demand responsiveness are the prevention of future electricity crises and the reduction of electricity prices. Additional goals for price responsiveness include equity through cost of service pricing, and customer control of electricity usage and bills. The technology developed and evaluated in this report could be used to support numerous forms of DR programs and tariffs. For the purpose of this report, we have defined three levels of Demand Response automation. Manual Demand Response involves manually turning off lights or equipment; this can be a labor-intensive approach. Semi-Automated Response involves the use of building energy management control systems for load shedding, where a preprogrammed load shedding strategy is initiated by facilities staff. Fully-Automated Demand Response is initiated at a building or facility through receipt of an external communications signal--facility staff set up a pre-programmed load shedding strategy which is automatically initiated by the system without the need for human intervention. We have defined this approach to be Auto-DR. An important concept in Auto-DR is that a facility manager is able to ''opt out'' or ''override'' an individual DR event if it occurs at a time when the reduction in end-use services is not desirable. This project sought to improve the feasibility and nature of Auto-DR strategies in large facilities. The research focused on technology development, testing

  12. International symposium on seismic evaluation of existing nuclear facilities. Book of invited and contributed papers

    International Nuclear Information System (INIS)

    2003-08-01

    In the past decade, seismic evaluation of existing Nuclear Power Plants (NPPs) has been an issue in western countries (particularly for the east of North America and for older NPPs in Europe) as well as in eastern European countries where systematic reviews of NPPs were carried out. Several Member States have still on-going seismic upgrading programmes. Presently. projects of plant life extension create an additional interest in safety evaluation of existing NPPs. Seismic evaluation is also an issue for other nuclear facilities. In western countries. some older facilities (laboratories, research reactors, fuel plants...) have been designed without taking into account (or poorly taking into account) earthquake input, even on seismic sites. In eastern countries, the situation is not yet clearly evaluated. In several countries concerns are expressed regarding research reactors. Generally speaking, the seismic evaluation of these nuclear facilities is not so advanced as the evaluation of NPPs and presents a wider range of different situations. Those safety issues raised by the seismic evaluation of existing NPPs are addressed in an IAEA Safety Report 'Seismic Evaluation of Existing Nuclear Power Plants' (2003). Other nuclear facilities are, at least partly, covered by IAEA-TECDOC 1347 'Design of Nuclear Facilities other than NPPs in Relation to External Events, with a Special Emphasis on Earthquake' (2003) that supersedes the former TECDOC 348 'Earthquake Resistant Design of Nuclear Facilities with Limited Radioactive Inventory' (1985). Concurrently with the publishing of relevant documentation, the IAEA has organized this Symposium in order to foster the exchange of information on topical issues in seismic evaluation of existing nuclear facilities, with the aim of: consolidating an international consensus on the present status of these issues; promoting a homogeneous engineering approach of their resolution; identifying the needs for strengthening international co

  13. International symposium on seismic evaluation of existing nuclear facilities. Book of invited and contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-08-01

    In the past decade, seismic evaluation of existing Nuclear Power Plants (NPPs) has been an issue in western countries (particularly for the east of North America and for older NPPs in Europe) as well as in eastern European countries where systematic reviews of NPPs were carried out. Several Member States have still on-going seismic upgrading programmes. Presently. projects of plant life extension create an additional interest in safety evaluation of existing NPPs. Seismic evaluation is also an issue for other nuclear facilities. In western countries. some older facilities (laboratories, research reactors, fuel plants...) have been designed without taking into account (or poorly taking into account) earthquake input, even on seismic sites. In eastern countries, the situation is not yet clearly evaluated. In several countries concerns are expressed regarding research reactors. Generally speaking, the seismic evaluation of these nuclear facilities is not so advanced as the evaluation of NPPs and presents a wider range of different situations. Those safety issues raised by the seismic evaluation of existing NPPs are addressed in an IAEA Safety Report 'Seismic Evaluation of Existing Nuclear Power Plants' (2003). Other nuclear facilities are, at least partly, covered by IAEA-TECDOC 1347 'Design of Nuclear Facilities other than NPPs in Relation to External Events, with a Special Emphasis on Earthquake' (2003) that supersedes the former TECDOC 348 'Earthquake Resistant Design of Nuclear Facilities with Limited Radioactive Inventory' (1985). Concurrently with the publishing of relevant documentation, the IAEA has organized this Symposium in order to foster the exchange of information on topical issues in seismic evaluation of existing nuclear facilities, with the aim of: consolidating an international consensus on the present status of these issues; promoting a homogeneous engineering approach of their resolution; identifying the needs for strengthening international co

  14. On the Evaluation of Outlier Detection and One-Class Classification Methods

    DEFF Research Database (Denmark)

    Swersky, Lorne; Marques, Henrique O.; Sander, Jörg

    2016-01-01

    It has been shown that unsupervised outlier detection methods can be adapted to the one-class classification problem. In this paper, we focus on the comparison of oneclass classification algorithms with such adapted unsupervised outlier detection methods, improving on previous comparison studies ...

  15. Removal site evaluation report for the Isotope Facilities at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This removal site evaluation (RmSE) report of the Isotope Facilities at Oak Ridge National Laboratory (ORNL) was prepared to provide the Environmental Restoration Program with information necessary to evaluate whether hazardous and/or radiological contaminants in and around the Isotopes Facility pose a substantial risk to human health or the environment and if remedial site evaluations (RSEs) or removal actions are required. The scope of the project included: (1) a review of historical evidence regarding operations and use of the facility; (2) interviews with facility personnel concerning current and past operating practices; (3) a site inspection; and (4) identification of hazard areas requiring maintenance, removal, or remedial actions. The results of RmSE indicate that no substantial risks exist from contaminants present in the Isotope Facilities because adequate controls and practices exist to protect human health and the environment. The recommended correction from the RmSE are being conducted as maintenance actions; accordingly, this RmSE is considered complete and terminated.

  16. Removal site evaluation report for the Isotope Facilities at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-07-01

    This removal site evaluation (RmSE) report of the Isotope Facilities at Oak Ridge National Laboratory (ORNL) was prepared to provide the Environmental Restoration Program with information necessary to evaluate whether hazardous and/or radiological contaminants in and around the Isotopes Facility pose a substantial risk to human health or the environment and if remedial site evaluations (RSEs) or removal actions are required. The scope of the project included: (1) a review of historical evidence regarding operations and use of the facility; (2) interviews with facility personnel concerning current and past operating practices; (3) a site inspection; and (4) identification of hazard areas requiring maintenance, removal, or remedial actions. The results of RmSE indicate that no substantial risks exist from contaminants present in the Isotope Facilities because adequate controls and practices exist to protect human health and the environment. The recommended correction from the RmSE are being conducted as maintenance actions; accordingly, this RmSE is considered complete and terminated

  17. Evaluation of the ACR and SLICC classification criteria in juvenile-onset systemic lupus erythematosus: a longitudinal analysis.

    Science.gov (United States)

    Lythgoe, H; Morgan, T; Heaf, E; Lloyd, O; Al-Abadi, E; Armon, K; Bailey, K; Davidson, J; Friswell, M; Gardner-Medwin, J; Haslam, K; Ioannou, Y; Leahy, A; Leone, V; Pilkington, C; Rangaraj, S; Riley, P; Tizard, E J; Wilkinson, N; Beresford, M W

    2017-10-01

    Objectives The Systemic Lupus International Collaborating Clinics (SLICC) group proposed revised classification criteria for systemic lupus erythematosus (SLICC-2012 criteria). This study aimed to compare these criteria with the well-established American College of Rheumatology classification criteria (ACR-1997 criteria) in a national cohort of juvenile-onset systemic lupus erythematosus (JSLE) patients and evaluate how patients' classification criteria evolved over time. Methods Data from patients in the UK JSLE Cohort Study with a senior clinician diagnosis of probable evolving, or definite JSLE, were analyzed. Patients were assessed using both classification criteria within 1 year of diagnosis and at latest follow up (following a minimum 12-month follow-up period). Results A total of 226 patients were included. The SLICC-2012 was more sensitive than ACR-1997 at diagnosis (92.9% versus 84.1% p < 0.001) and after follow up (100% versus 92.0% p < 0.001). Most patients meeting the SLICC-2012 criteria and not the ACR-1997 met more than one additional criterion on the SLICC-2012. Conclusions The SLICC-2012 was better able to classify patients with JSLE than the ACR-1997 and did so at an earlier stage in their disease course. SLICC-2012 should be considered for classification of JSLE patients in observational studies and clinical trial eligibility.

  18. Impact of corpus domain for sentiment classification: An evaluation study using supervised machine learning techniques

    Science.gov (United States)

    Karsi, Redouane; Zaim, Mounia; El Alami, Jamila

    2017-07-01

    Thanks to the development of the internet, a large community now has the possibility to communicate and express its opinions and preferences through multiple media such as blogs, forums, social networks and e-commerce sites. Today, it becomes clearer that opinions published on the web are a very valuable source for decision-making, so a rapidly growing field of research called “sentiment analysis” is born to address the problem of automatically determining the polarity (Positive, negative, neutral,…) of textual opinions. People expressing themselves in a particular domain often use specific domain language expressions, thus, building a classifier, which performs well in different domains is a challenging problem. The purpose of this paper is to evaluate the impact of domain for sentiment classification when using machine learning techniques. In our study three popular machine learning techniques: Support Vector Machines (SVM), Naive Bayes and K nearest neighbors(KNN) were applied on datasets collected from different domains. Experimental results show that Support Vector Machines outperforms other classifiers in all domains, since it achieved at least 74.75% accuracy with a standard deviation of 4,08.

  19. Evaluation of Semi-supervised Learning for Classification of Protein Crystallization Imagery.

    Science.gov (United States)

    Sigdel, Madhav; Dinç, İmren; Dinç, Semih; Sigdel, Madhu S; Pusey, Marc L; Aygün, Ramazan S

    2014-03-01

    In this paper, we investigate the performance of two wrapper methods for semi-supervised learning algorithms for classification of protein crystallization images with limited labeled images. Firstly, we evaluate the performance of semi-supervised approach using self-training with naïve Bayesian (NB) and sequential minimum optimization (SMO) as the base classifiers. The confidence values returned by these classifiers are used to select high confident predictions to be used for self-training. Secondly, we analyze the performance of Yet Another Two Stage Idea (YATSI) semi-supervised learning using NB, SMO, multilayer perceptron (MLP), J48 and random forest (RF) classifiers. These results are compared with the basic supervised learning using the same training sets. We perform our experiments on a dataset consisting of 2250 protein crystallization images for different proportions of training and test data. Our results indicate that NB and SMO using both self-training and YATSI semi-supervised approaches improve accuracies with respect to supervised learning. On the other hand, MLP, J48 and RF perform better using basic supervised learning. Overall, random forest classifier yields the best accuracy with supervised learning for our dataset.

  20. The impact of complications on quality of life following colorectal surgery : A prospective cohort study to evaluate the Clavien-Dindo classification system

    NARCIS (Netherlands)

    Bosma, E.; Pullens, M.J.J.; de Vries, J.; Roukema, J.A.

    2016-01-01

    Aim This prospective cohort study was performed to evaluate the impact of complications on quality of life (QOL) in colorectal surgery. The Clavien–Dindo complication classification (CDCC) is promising, but has not been evaluated by relating the classification to patient-reported outcome measures.

  1. Engineering Evaluation/Cost Analysis for the 100-N Area Ancillary Facilities and Integration Plan

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1997-09-01

    This document presents the results of an engineering evaluation/cost analysis (EE/CA) that was conducted to evaluate alternatives for addressing final disposition of contaminated buildings and structures in the 100-N Area of the Hanford Site. The Hanford Site is located in southeastern Washington State and is owned by the U.S. Government and operated by the U.S. Department of Energy, Richland Operations Office (RL). In November 1989, the 100 Area of the Hanford Site (as well as the 200, 300, and 1100 Areas) was placed on the U.S. Environmental Protection Agency's National Priorities List (NPL) under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980. The 100 Area NPL includes the 100-N Area, which is in various stages of the remediation process. It has been determined by RL that hazardous substances in the 100-N Area ancillary facilities may present a potential threat to human health or the environment, and that a non-time critical removal action at these facilities is warranted. To help determine the most appropriate action, RL, in cooperation with the Washington State Department of Ecology (Ecology) and the EPA, has prepared this EE/CA. The scope of the evaluation includes the inactive contaminated ancillary facilities in the 100-N Area, the facilities residing in the buffer zone, and the Hanford Generating Plant (HGP) and the solid waste management units (SWMUs) inside HGP support facilities. The 105-N Reactor and 109-N Heat Exchange facilities are excluded from this EE/CA evaluation

  2. EVALUATION OF ECONOMIC EFFICIENCY PERTAINING TO USAGE OF AUTOMOTIVE TRANSPORT FACILITIES WHILE EXECUTING INTERNATIONAL CARGO TRANSPORTATION

    Directory of Open Access Journals (Sweden)

    R. B. Ivut

    2010-01-01

    Full Text Available The paper presents a methodology for evaluation of economic efficiency pertaining to usage of automotive transport facilities while executing international cargo transportation on the basis of average internal norm calculation of automotive operational profitability of a specific model under conditions which are typical for the given market by an average carrier.

  3. Evaluating physical protection systems of licensed nuclear facilities using systems engineered inspection guidance

    International Nuclear Information System (INIS)

    Bradley, R.T.; Olson, A.W.; Rogue, F.; Scala, S.; Richard, E.W.

    1980-01-01

    The Lawrence Livermore National Laboratory (LLNL) and the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) have applied a systems engineering approach to provide the NRC Office of Inspection and Enforcement (IE) with improved methods and guidance for evaluating the physical protection systems of licensed nuclear facilities

  4. Acceptance criteria for the evaluation of Category 1 fuel cycle facility physical security plans

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, P.A.

    1991-10-01

    This NUREG document presents criteria developed from US Nuclear Regulatory Commission regulations for the evaluation of physical security plans submitted by Category 1 fuel facility licensees. Category 1 refers to those licensees who use or possess a formula quantity of strategic special nuclear material.

  5. Evaluation of effectiveness of physical protection systems at nuclear facilities in the Slovak Republic

    International Nuclear Information System (INIS)

    Stefulova, A.

    2001-01-01

    This paper contains a short presentation of the state supervision in approach to the evaluation of physical protection systems at the nuclear facilities as one kind of measure used to prevent combat illicit trafficking of nuclear and other radioactive materials in the Slovak Republic. (author)

  6. Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities.

    Science.gov (United States)

    Glasgow, Glenn P

    2006-09-01

    Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities NCRP Report No. 151, 2005, 246 pp. (Hardcover $100). National Council on Radiation Protection and Measurements, 7910 Woodmont Avenue, Suite 400, Bethesda, MD 20814-3095. ISBN-10 0-0929600-87-8; http://www.NCRPonline.org. © 2006 American Association of Physicists in Medicine.

  7. Acceptance criteria for the evaluation of Category 1 fuel cycle facility physical security plans

    International Nuclear Information System (INIS)

    Dwyer, P.A.

    1991-10-01

    This NUREG document presents criteria developed from US Nuclear Regulatory Commission regulations for the evaluation of physical security plans submitted by Category 1 fuel facility licensees. Category 1 refers to those licensees who use or possess a formula quantity of strategic special nuclear material

  8. An evaluation of sampling and full enumeration strategies for Fisher Jenks classification in big data settings

    Science.gov (United States)

    Rey, Sergio J.; Stephens, Philip A.; Laura, Jason R.

    2017-01-01

    Large data contexts present a number of challenges to optimal choropleth map classifiers. Application of optimal classifiers to a sample of the attribute space is one proposed solution. The properties of alternative sampling-based classification methods are examined through a series of Monte Carlo simulations. The impacts of spatial autocorrelation, number of desired classes, and form of sampling are shown to have significant impacts on the accuracy of map classifications. Tradeoffs between improved speed of the sampling approaches and loss of accuracy are also considered. The results suggest the possibility of guiding the choice of classification scheme as a function of the properties of large data sets.

  9. Radiological safety evaluation for a Waste Transfer Facility at Savannah River Site

    International Nuclear Information System (INIS)

    Ades, M.J.

    1993-01-01

    This paper provides a review of the radiological safety evaluation performed for a Waste Transfer Facility (WTF) located at the Savannah River Site (SRS). This facility transfers liquid radioactive waste between various waste processing facilities and waste storage facilities. The WTF includes functional components such as the diversion box and the pump pits, waste transfer lines, and the outside yard service piping and electrical services. The WSRC methodology is used to evaluate the consequences of postulated accidents that result in the release of radioactive material. Such accidents include transfer line breaks, underground liquid pathway release, fire in pump tank cells and HEPA filters, accidents due to natural phenomena, and externally induced events. Chemical hazards accidents are not considered. The analysis results indicate that the calculated mean onsite and offsite radiological consequences are bounded by the corresponding WSRC dose limits for each accident considered. Moreover, the results show that the maximum onsite and offsite doses calculated for the WTF are lower than the maximum doses determined for the whole radioactive waste facility where the WTF is located

  10. Annual evaluation of routine radiological survey/monitoring frequencies for the High Ranking Facilities Deactivating Project at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-12-01

    The Bethel Valley Watershed at the Oak Ridge National Laboratory (ORNL) has several Environmental Management (EM) facilities that are designated for deactivation and subsequent decontamination and decommissioning (D and D). The Surplus Facilities Program at ORNL provides surveillance and maintenance support for these facilities as deactivation objectives are completed to reduce the risks associated with radioactive material inventories, etc. The Bechtel Jacobs Company LLC Radiological Control (RADCON) Program has established requirements for radiological monitoring and surveying radiological conditions in these facilities. These requirements include an annual evaluation of routine radiation survey and monitoring frequencies. Radiological survey/monitoring frequencies were evaluated for two High Ranking Facilities Deactivation Project facilities, the Bulk Shielding Facility and Tower Shielding Facility. Considerable progress has been made toward accomplishing deactivation objectives, thus the routine radiological survey/monitoring frequencies are being reduced for 1999. This report identifies the survey/monitoring frequency adjustments and provides justification that the applicable RADCON Program requirements are also satisfied

  11. Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This Department of Energy (DOE) is approved for use by all components of DOE. It contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE Non-Reactor Nuclear Facilities. Adherence with these guidelines will provide consistency and uniformity in Criticality Safety Evaluations (CSEs) across the complex and will document compliance with DOE Order 5480.24 requirements as they pertain to CSEs.

  12. Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities

    International Nuclear Information System (INIS)

    1998-09-01

    This Department of Energy (DOE) is approved for use by all components of DOE. It contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE Non-Reactor Nuclear Facilities. Adherence with these guidelines will provide consistency and uniformity in Criticality Safety Evaluations (CSEs) across the complex and will document compliance with DOE Order 5480.24 requirements as they pertain to CSEs

  13. Spent unreprocessed fuel (SURF) facility evaluation plan of the alternative storage concepts

    International Nuclear Information System (INIS)

    Berry, S.M.

    1978-01-01

    Concepts were evaluated for the storage of unreprocessed spent fuel in a retrievable surface storage facility. This document provides a systematic format for making a concept selection from the seven alternative concepts presented in RHO-LD-2. Results of the evaluation was that the Drywell concept was rated highest with the Water Basin Concept and the Sealed Storage Cask concept with multiple canisters of SURF coming in a close second and third

  14. Language and functionality of post-stroke adults: evaluation based on International Classification of Functioning, Disability and Health (ICF).

    Science.gov (United States)

    Santana, Maria Tereza Maynard; Chun, Regina Yu Shon

    2017-03-09

    Cerebrovascular accident is an important Public Health problem because of the high rates of mortality and sequelae such as language disorders. The conceptual health changes have led to the incorporation of functional and social aspects in the assessments as proposed by the World Health Organization in the International Classification of Functioning, Disability and Health. The purpose was to evaluate and classify language aspects, functionality and participation of post-stroke individuals based on the concepts of the International Classification of Functioning, Disability and Health and characterize the sociodemographic profile of participants. Data collection was carried out through the application of a clinical instrument to evaluate language, participation and functionality in fifty individuals based on the International Classification of Functioning, Disability and Health. The age of the participants varied between 32 and 88 years, and the majority were elderly men. Among body functions, the participants reported more difficulties in "memory functions". As for activity and participation, more difficulties were reported in "recreation and leisure". As for environmental factors, the component "healthcare professionals" was indicated as a facilitator by the majority of participants. The results show the impact of language difficulties in the lives of post-stroke adults and reinforce the applicability of the International Classification of Functioning, Disability and Health as an important complementary tool for assessing language, functionality and participation in a comprehensive and humane approach, towards the improvement of health assistance in ambulatory care.

  15. A facility for long term evaluation and quality assurance of LHCb Vertex Detector modules

    CERN Document Server

    Marinho, F; Dimattia, R; Doherty, F; Dumps, R; Gersabeck, M; Melone, J; Parkes, C; Saavedra, A; Tobin, M

    2007-01-01

    This note describes the facility developed for long term evaluation and quality assurance of the LHCb Vertex Detector modules, known as the 'Glasgow Burn-in System'. This facility was developed to ensure that the modules conform to stringent quality levels. The system was able to uncover any weaknesses that could be introduced during the manufacturing and assembly of the components or during the transport of the modules to CERN. The system consisted of: a high resolution microscope for visual inspections; and a burn-in system to operate cooled modules in vacuum. The main components of the burn-in system were a vacuum system, a cooling system and a DAQ system.

  16. Exposure dose evaluation of worker at radioactive waste incineration facility on KAERI

    International Nuclear Information System (INIS)

    Park, Sang Kyu; Jeon, Jong Seon; Kim, Youn Hwa; Lee, Jae Min; Lee, Gi Won

    2011-01-01

    An incineration treatment of inflammable radioactive wastes leads to have a reduction effect of disposal cost and also to contribute an enhancement of safety at a disposal site by taking the advantage of stabilization of the wastes which is accomplished by converting organic materials into inorganic materials. As it was required for an incineration technology, KAERI (Korea Atomic Energy Research Institute) has developed a pilot incineration process and then constructed a demonstration incineration facility having based on the operating experiences of the pilot process. In this study, worker exposure doses were evaluated to confirm safety of workers before the demonstration incineration facility will commence a commercial. (author)

  17. Source term model evaluations for the low-level waste facility performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Yim, M.S.; Su, S.I. [North Carolina State Univ., Raleigh, NC (United States)

    1995-12-31

    The estimation of release of radionuclides from various waste forms to the bottom boundary of the waste disposal facility (source term) is one of the most important aspects of LLW facility performance assessment. In this work, several currently used source term models are comparatively evaluated for the release of carbon-14 based on a test case problem. The models compared include PRESTO-EPA-CPG, IMPACTS, DUST and NEFTRAN-II. Major differences in assumptions and approaches between the models are described and key parameters are identified through sensitivity analysis. The source term results from different models are compared and other concerns or suggestions are discussed.

  18. Threshold of toxicological concern values for non-genotoxic effects in industrial chemicals: re-evaluation of the Cramer classification.

    Science.gov (United States)

    Kalkhof, H; Herzler, M; Stahlmann, R; Gundert-Remy, U

    2012-01-01

    The TTC concept employs available data from animal testing to derive a distribution of NOAELs. Taking a probabilistic view, the 5th percentile of the distribution is taken as a threshold value for toxicity. In this paper, we use 824 NOAELs from repeated dose toxicity studies of industrial chemicals to re-evaluate the currently employed TTC values, which have been derived for substances grouped according to the Cramer scheme (Cramer et al. in Food Cosm Toxicol 16:255-276, 1978) by Munro et al. (Food Chem Toxicol 34:829-867, 1996) and refined by Kroes and Kozianowski (Toxicol Lett 127:43-46, 2002), Kroes et al. 2000. In our data set, consisting of 756 NOAELs from 28-day repeated dose testing and 57 NOAELs from 90-days repeated dose testing, the experimental NOAEL had to be extrapolated to chronic TTC using regulatory accepted extrapolation factors. The TTC values derived from our data set were higher than the currently used TTC values confirming the safety of the latter. We analysed the prediction of the Cramer classification by comparing the classification by this tool with the guidance values for classification according to the Globally Harmonised System of classification and labelling of the United Nations (GHS). Nearly 90% of the chemicals were in Cramer class 3 and assumed as highly toxic compared to 22% according to the GHS. The Cramer classification does underestimate the toxicity of chemicals only in 4.6% of the cases. Hence, from a regulatory perspective, the Cramer classification scheme might be applied as it overestimates hazard of a chemical.

  19. Evaluation of syngas production unit cost of bio-gasification facility using regression analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Yangyang; Parajuli, Prem B.

    2011-08-10

    Evaluation of economic feasibility of a bio-gasification facility needs understanding of its unit cost under different production capacities. The objective of this study was to evaluate the unit cost of syngas production at capacities from 60 through 1800Nm 3/h using an economic model with three regression analysis techniques (simple regression, reciprocal regression, and log-log regression). The preliminary result of this study showed that reciprocal regression analysis technique had the best fit curve between per unit cost and production capacity, with sum of error squares (SES) lower than 0.001 and coefficient of determination of (R 2) 0.996. The regression analysis techniques determined the minimum unit cost of syngas production for micro-scale bio-gasification facilities of $0.052/Nm 3, under the capacity of 2,880 Nm 3/h. The results of this study suggest that to reduce cost, facilities should run at a high production capacity. In addition, the contribution of this technique could be the new categorical criterion to evaluate micro-scale bio-gasification facility from the perspective of economic analysis.

  20. Calculation of parameters for inspection planning and evaluation: mixed-oxide fuel fabrication facilities

    International Nuclear Information System (INIS)

    Reardon, P.T.; Mullen, M.F.

    1982-08-01

    As part of Task C.35 (Calculation of Parameters for Inspection Planning and Evaluation) of the US Program of Technical Assistance to IAEA Safeguards, Pacific Northwest Laboratory has performed some quantitative analyses of IAEA inspection activities for mixed-oxide fuel fabrication facilities. There were four distinct efforts involved in this task. These were as follows: show the effect on a material balance verification of using two variables measurement methods in some strata; perform additional calculations for the reference facility described in STR-89; modify the INSPECT computer programs to be used as an after-inspection analysis tool, as well as a preinspection planning tool; provide written comments and explantations of text and graphs of the first draft of STR-89, Safeguards Considerations for Mixed-Oxide Fuel Element Fabrication Facilities, by W. Bahm, T. Shea, and D. Tolchenkov, System Studies Section, IAEA

  1. Multidisciplinary approach to evaluating welfare of veal calves in commercial facilities.

    Science.gov (United States)

    Stull, C L; McDonough, S P

    1994-09-01

    Due to pending legislation and public concerns, a multidisciplinary approach was designed to investigate the welfare of special-fed veal calves in commercial veal facilities. Concerns included housing conditions, dietary regimens, management practices, and behavioral aspects imposed on special-fed calves. Four categories of parameters including environment and housing, nutrition, health and stress, and behavior provided a broad base of evaluating veal systems. Observations and samples were collected on 550 Holstein bull calves located in 10 commercial veal facilities. Each facility was visited to collect data during wk 0 (week of arrival of the calves), 2, 4, 8, 12, and 16. Nine facilities used individual stalls 48 to 55 cm in width with tethers attached to the front of the stalls. One facility housed 30 calves in group pens after obtaining calves at 8 wk of age. Ammonia, carbon monoxide, and hydrogen sulfide gas did not exceed the permissible limit for humans in any facility. All facilities exceeded the 2-foot-candle recommendation for lighting. The average daily gain of calves was .85 kg during wk 0 to 8 and 1.18 kg during wk 8 to 16. Dietary iron levels decreased from 209 ppm at wk 0 to 32 ppm at wk 16. At 16 wk, 25% of calves were marginally anemic and 10% clinically anemic. Overall mortality was 4.2%. Stress indices such as plasma cortisol concentrations or neutrophil to lymphocyte ratios declined as calves approached market weight. In either pens or stalls, calves spent approximately 25 and 75% of time in standing and lying positions, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Evaluation and Selection of Renewable Energy Technologies for Highway Maintenance Facilities

    Science.gov (United States)

    Andrews, Taylor

    The interest in renewable energy has been increasing in recent years as attempts to reduce energy costs as well the consumption of fossil fuels are becoming more common. Companies and organizations are recognizing the increasing reliance on limited fossil fuels' resources, and as competition and costs for these resources grow, alternative solutions are becoming more appealing. Many federally run buildings and associations also have the added pressure of meeting the mandates of federal energy policies that dictate specific savings or reductions. Federal highway maintenance facilities run by the Department of Transportation fall into this category. To help meet energy saving goals, an investigation into potential renewable energy technologies was completed for the Ohio Department of Transportation. This research examined several types of renewable energy technologies and the major factors that affect their performance and evaluated their potential for implementation at highway maintenance facilities. Facilities energy usage data were provided, and a facility survey and site visits were completed to enhance the evaluation of technologies and the suitability for specific projects. Findings and technology recommendations were presented in the form of selection matrices, which were designed to help make selections in future projects. The benefits of utilization of other tools such as analysis software and life cycle assessments were also highlighted. These selection tools were designed to be helpful guides when beginning the pursuit of a renewable energy technology for highway maintenance facilities, and can be applied to other similar building types and projects. This document further discusses the research strategies and findings as well as the recommendations that were made to the personnel overseeing Ohio's highway maintenance facilities.

  3. Empirical evaluation of lung solubilities of airborne contamination at Harwell facilities

    International Nuclear Information System (INIS)

    Bull, R. K.; Wilson, G.

    2011-01-01

    Lung solubility is the key parameter in determining intakes and doses from inhalation of airborne contamination. However, information on lung solubility can be difficult to acquire, particularly for the historical exposures that are of relevance to lifetime-dose reconstruction. In this study, an empirical approach has been made in which over 200 dose assessments, mainly for Pu and Am, from the period 1986 to 2005 were re-evaluated and the solubility mix required for the best fit to the data was determined. The average of these solubility mixtures for any building or facility can be used as the default solubility for retrospective dose assessments for that facility. Results are presented for a radiochemistry facility, a materials development facility and a waste-storage/handling building at Harwell. The latter two areas are characterised by aerosols that are predominantly insoluble (type S), whereas the radiochemistry facility has a heterogeneous mixture of insoluble and soluble aerosols. The implications of these results for dose reconstruction are discussed in the paper. (authors)

  4. CMT scaling analysis and distortion evaluation in passive integral test facility

    International Nuclear Information System (INIS)

    Deng Chengcheng; Qin Benke; Wang Han; Chang Huajian

    2013-01-01

    Core makeup tank (CMT) is the crucial device of AP1000 passive core cooling system, and reasonable scaling analysis of CMT plays a key role in the design of passive integral test facilities. H2TS method was used to perform scaling analysis for both circulating mode and draining mode of CMT. And then, the similarity criteria for CMT important processes were applied in the CMT scaling design of the ACME (advanced core-cooling mechanism experiment) facility now being built in China. Furthermore, the scaling distortion results of CMT characteristic Ⅱ groups of ACME were calculated. At last, the reason of scaling distortion was analyzed and the distortion evaluation was conducted for ACME facility. The dominant processes of CMT circulating mode can be adequately simulated in the ACME facility, but the steam condensation process during CMT draining is not well preserved because the excessive CMT mass leads to more energy to be absorbed by cold metal. However, comprehensive analysis indicates that the ACME facility with high-pressure simulation scheme is able to properly represent CMT's important phenomena and processes of prototype nuclear plant. (authors)

  5. Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities

    International Nuclear Information System (INIS)

    Pujades, M C; Granero, D; Vijande, J; Ballester, F; Perez-Calatayud, J; Papagiannis, P; Siebert, F A

    2014-01-01

    In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for 192 Ir and 60 Co HDR applications to account for several different bunker layouts. For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emitted by 192 Ir and 60 Co will reduce the lead thickness by a factor of five for 192 Ir and ten for 60 Co. This will significantly lighten the door and hence simplify construction and operating requirements for all bunkers. The adaptation proposed in this study to estimate the air-kerma rate at the door depends on the complexity of the maze: it provides good results for bunkers with a maze (i.e. similar to those used for linacs for which the NCRP 151 methodology was developed) but fails for less conventional designs. For those facilities, a specific Monte Carlo study is in order for reasons of safety and cost-effectiveness. (paper)

  6. Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities.

    Science.gov (United States)

    Pujades, M C; Granero, D; Vijande, J; Ballester, F; Perez-Calatayud, J; Papagiannis, P; Siebert, F A

    2014-12-01

    In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emitted by (192)Ir and (60)Co will reduce the lead thickness by a factor of five for (192)Ir and ten for (60)Co. This will significantly lighten the door and hence simplify construction and operating requirements for all bunkers.The adaptation proposed in this study to estimate the air-kerma rate at the door depends on the complexity of the maze: it provides good results for bunkers with a maze (i.e. similar to those used for linacs for which the NCRP 151 methodology was developed) but fails for less conventional designs. For those facilities, a specific Monte Carlo study is in order for reasons of safety and cost-effectiveness.

  7. Process Evaluation of Communitisation Programme in Public Sector Health Facilities, Mokokchung District, Nagaland, 2015.

    Science.gov (United States)

    Tushi, Aonungdok; Kaur, Prabhdeep

    2017-01-01

    Public sector health facilities were poorly managed due to a history of conflict in Nagaland, India. Government of Nagaland introduced "Nagaland Communitisation of Public Institutions and Services Act" in 2002. Main objectives of the evaluation were to review the functioning of Health Center Managing Committees (HCMCs), deliver health services in the institutions managed by HCMC, identify strengths as well as challenges perceived by HCMC members in the rural areas of Mokokchung district, Nagaland. The evaluation was made using input, process and output indicators. A doctor, the HCMC Chairman and one member from each of the three community health centers (CHC) and four primary health centers (PHC) were surveyed using a semi-structured questionnaire and an in-depth interview guide. Proportions for quantitative data were computed and key themes from the same were identified. Overall; the infrastructure, equipment and outpatient/inpatient service availability was satisfactory. There was a lack of funds and shortage of doctors, drugs as well as laboratory facilities. HCMCs were in place and carried out administrative activities. HCMCs felt ownership, mobilized community contributions and managed human resources. HCMC members had inadequate funds for their transport and training. They faced challenges in service delivery due to political interference and lack of adequate human, material, financial resources. Communitisation program was operational in the district. HCMC members felt the ownership of health facilities. Administrative, political support and adequate funds from the government are needed for effective functioning of HCMCs and optimal service delivery in public sector facilities.

  8. Seismic design and evaluation criteria for DOE facilities (DOE-STD-1020-XX)

    International Nuclear Information System (INIS)

    Short, S.A.; Kennedy, R.P.; Murray, R.C.

    1993-01-01

    Seismic design and evaluation criteria for DOE facilities are provided in DOE-STD-1020-XX. The criteria include selection of design/evaluation seismic input from probabilistic seismic hazard curves combined with commonly practiced deterministic response evaluation methods and acceptance criteria with controlled levels of conservatism. Conservatism is intentionally introduced in specification of material strengths and capacities, in the allowance of limited inelastic behavior and by a seismic load factor. These criteria are based on the performance or risk goals specified in DOE 5480.28. Criteria have been developed following a graded approach for several performance goals ranging from that appropriate for normal-use facilities to that appropriate for facilities involving hazardous or critical operations. Performance goals are comprised of desired behavior and of the probability of not achieving that behavior. Following the seismic design/evaluation criteria of DOE-STD-1020-XX is sufficient to demonstrate that the probabilistic performance or risk goals are achieved. The criteria are simple procedures but with a sound, rigorous basis for the achievement of goals

  9. An Evaluation of Peak Finding for DVR Classification of Biological Data

    KAUST Repository

    Knoll, Aaron

    2012-01-01

    In medicine and the life sciences, volume data are frequently entropic, containing numerous features at different scales as well as significant noise from the scan source. Conventional transfer function approaches for direct volume rendering have difficulty handling such data, resulting in poor classification or undersampled rendering. Peak finding addresses issues in classifying noisy data by explicitly solving for isosurfaces at desired peaks in a transfer function. As a result, one can achieve better classification and visualization with fewer samples and correspondingly higher performance. This paper applies peak finding to several medical and biological data sets, particularly examining its potential in directly rendering unfiltered and unsegmented data.

  10. Evaluating Method Engineer Performance: an error classification and preliminary empirical study

    Directory of Open Access Journals (Sweden)

    Steven Kelly

    1998-11-01

    Full Text Available We describe an approach to empirically test the use of metaCASE environments to model methods. Both diagrams and matrices have been proposed as a means for presenting the methods. These different paradigms may have their own effects on how easily and well users can model methods. We extend Batra's classification of errors in data modelling to cover metamodelling, and use it to measure the performance of a group of metamodellers using either diagrams or matrices. The tentative results from this pilot study confirm the usefulness of the classification, and show some interesting differences between the paradigms.

  11. Numerical Evaluation of a Light-Gas Gun Facility for Impact Test

    Directory of Open Access Journals (Sweden)

    C. Rahner

    2014-01-01

    Full Text Available Experimental tests which match the application conditions might be used to properly evaluate materials for specific applications. High velocity impacts can be simulated using light-gas gun facilities, which come in different types and complexities. In this work different setups for a one-stage light-gas gun facility have been numerically analyzed in order to evaluate their suitability for testing materials and composites used as armor protection. A maximal barrel length of 6 m and a maximal reservoir pressure of a standard industrial gas bottle (20 MPa were chosen as limitations. The numerical predictions show that it is not possible to accelerate the projectile directly to the desired velocity with nitrogen, helium, or hydrogen as propellant gas. When using a sabot corresponding to a higher bore diameter, the necessary velocity is achievable with helium and hydrogen gases.

  12. [Structure of pain management facilities in Germany : Classification of medical and psychological pain treatment services-Consensus of the Joint Commission of the Professional Societies and Organizations for Quality in Pain Medicine].

    Science.gov (United States)

    Müller-Schwefe, G H H; Nadstawek, J; Tölle, T; Nilges, P; Überall, M A; Laubenthal, H J; Bock, F; Arnold, B; Casser, H R; Cegla, T H; Emrich, O M D; Graf-Baumann, T; Henning, J; Horlemann, J; Kayser, H; Kletzko, H; Koppert, W; Längler, K H; Locher, H; Ludwig, J; Maurer, S; Pfingsten, M; Schäfer, M; Schenk, M; Willweber-Strumpf, A

    2016-06-01

    On behalf of the Medical/Psychological Pain Associations, Pain Patients Alliance and the Professional Association of Pain Physicians and Psychologists, the Joint Commission of Professional Societies and Organizations for Quality in Pain Medicine, working in close collaboration with the respective presidents, has developed verifiable structural and process-related criteria for the classification of medical and psychological pain treatment facilities in Germany. Based on the established system of graded care in Germany and on existing qualifications, these criteria also argue for the introduction of a basic qualification in pain medicine. In addition to the first-ever comprehensive description of psychological pain facilities, the criteria presented can be used to classify five different levels of pain facilities, from basic pain management facilities, to specialized institutions, to the Centre for Interdisciplinary Pain Medicine. The recommendations offer binding and verifiable criteria for quality assurance in pain medicine and improved pain treatment.

  13. Evaluation of mercury in liquid waste processing facilities - Phase I report

    Energy Technology Data Exchange (ETDEWEB)

    Jain, V. [Savannah River Site (SRS), Aiken, SC (United States); Occhipinti, J. E. [Savannah River Site (SRS), Aiken, SC (United States); Shah, H. [Savannah River Site (SRS), Aiken, SC (United States); Wilmarth, W. R. [Savannah River Site (SRS), Aiken, SC (United States); Edwards, R. E. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-07-01

    This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.

  14. Evaluation of Mercury in Liquid Waste Processing Facilities - Phase I Report

    Energy Technology Data Exchange (ETDEWEB)

    Jain, V. [Savannah River Site (SRS), Aiken, SC (United States); Occhipinti, J. [Savannah River Site (SRS), Aiken, SC (United States); Shah, H. [Savannah River Site (SRS), Aiken, SC (United States); Wilmarth, B. [Savannah River Site (SRS), Aiken, SC (United States); Edwards, R. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-07-01

    This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.

  15. Methodology to evaluate the site standard seismic motion for a nuclear facility

    International Nuclear Information System (INIS)

    Soares, W.A.

    1983-03-01

    An overall view of the subjects involved in the determination of the site standard seismic motion to a nuclear facility is presented. The main topics discussed are: basic priciples of seismic instrumentation; dynamic and spectral concepts; design earthquakes definitions; fundamentals of seismology; empirical curves developed from prior seismic data; avalable methodologies and recommended procedures to evaluate the site standard seismic motion. (E.G.) [pt

  16. Methodology for worker neutron exposure evaluation in the PDCF facility design

    International Nuclear Information System (INIS)

    Scherpelz, R. I.; Traub, R. J.; Pryor, K. H.

    2004-01-01

    A project headed by Washington Group International is meant to design the Pit Disassembly and Conversion Facility (PDCF) to convert the plutonium pits from excessed nuclear weapons into plutonium oxide for ultimate disposition. Battelle staff are performing the shielding calculations that will determine appropriate shielding so that the facility workers will not exceed target exposure levels. The target exposure levels for workers in the facility are 5 mSv y -1 for the whole body and 100 mSv y -1 for the extremity, which presents a significant challenge to the designers of a facility that will process tons of radioactive material. The design effort depended on shielding calculations to determine appropriate thickness and composition for glove box walls, and concrete wall thicknesses for storage vaults. Pacific Northwest National Laboratory (PNNL) staff used ORIGEN-S and SOURCES to generate gamma and neutron source terms, and Monte Carlo (computer code for) neutron photon (transport) (MCNP-4C) to calculate the radiation transport in the facility. The shielding calculations were performed by a team of four scientists, so it was necessary to develop a consistent methodology. There was also a requirement for the study to be cost-effective, so efficient methods of evaluation were required. The calculations were subject to rigorous scrutiny by internal and external reviewers, so acceptability was a major feature of the methodology. Some of the issues addressed in the development of the methodology included selecting appropriate dose factors, developing a method for handling extremity doses, adopting an efficient method for evaluating effective dose equivalent in a non-uniform radiation field, modelling the reinforcing steel in concrete, and modularising the geometry descriptions for efficiency. The relative importance of the neutron dose equivalent compared with the gamma dose equivalent varied substantially depending on the specific shielding conditions and lessons were

  17. Evaluating heat-related mortality in Korea by objective classifications of 'air masses'

    Czech Academy of Sciences Publication Activity Database

    Kyselý, Jan; Huth, Radan; Kim, J.

    2010-01-01

    Roč. 30, č. 10 (2010), s. 1484-1501 ISSN 0899-8418 R&D Projects: GA ČR GC205/07/J044 Institutional research plan: CEZ:AV0Z30420517 Keywords : weather type classifications * air masses * biometeorology * human mortality * South Korea Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 2.479, year: 2010

  18. Evaluation of Different Methods for Soil Classifications by Using Geographic Information Systems and Remote Sensing

    Directory of Open Access Journals (Sweden)

    S. H Sanaeinejad

    2012-12-01

    Full Text Available Soil salinity is an important factor that affects plant growth and reduces production of plantat different growth stages Remote sensing technology and GIS have a great potential for monitoring dynamic soil processes such as salinity. In the present study the efficiency of remote sensing technology and its integration with GIS was examined to estimate soil salinity for Neyshabour basin. Different classification methods for soil salinity were also investigated. We used 6 bands of LandSat ETM+ for this study. Classification results obtained from applying mathematical models for the images were compared with different band combinations results. The area of saline and non saline soil classes were identified in the study area based on the both methods and also based on the combination of the two methods. The results showed that the best method for soil classification was using of the two methods in the first stage to separate two classes of saline and non saline soils and then classifying the non saline soils in the second stage. As the variation in the numerical values of the image for different soil salinity in the study area was small, it was concluded that there is a limit potential of LandSat ETM+ images for identifying and classification of soil salinity in such an area.

  19. Classification of fractures of the distal r[ius - Comparative evaluation of spiral CT images and X-rays

    International Nuclear Information System (INIS)

    Roehnert, W.; Nitzsche, H.; Franck, W.M.; Amlang, M.

    1998-01-01

    Within the framework of a prospective study 35 patients with fractures of the distal r[ius safely diagnosed to require surgery have been [ditionally scanned by spiral CT. For more exact diagnostic evaluation of the joint surfaces and the fractures, multiplane reconstructions have been m[e to enhance the information obtained from the primary, axial tomographic images. Two experts independently performed classification on the basis of the X-rays and the CT scans, applying the AO scheme and the method of Frykman. Classifications according to the AO scheme were found to agree for only 28.6 % of the patients, which means that 57.1 % of the fractures shown by the X-rays were more or less underassessed. Classification according to Frykman's method revealed fewer deviations and agreement in 51.4 % of the cases. Biplanar r[iography continues to be considered as the standard method for examination of distal r[ius fractures, but it is recommended to perform spiral CT scans for evaluation of more complex distal r[ius fractures because these may require different therapies according to fracture types. (orig./CB) [de

  20. Segmentation Based Classification of 3D Urban Point Clouds: A Super-Voxel Based Approach with Evaluation

    Directory of Open Access Journals (Sweden)

    Laurent Trassoudaine

    2013-03-01

    Full Text Available Segmentation and classification of urban range data into different object classes have several challenges due to certain properties of the data, such as density variation, inconsistencies due to missing data and the large data size that require heavy computation and large memory. A method to classify urban scenes based on a super-voxel segmentation of sparse 3D data obtained from LiDAR sensors is presented. The 3D point cloud is first segmented into voxels, which are then characterized by several attributes transforming them into super-voxels. These are joined together by using a link-chain method rather than the usual region growing algorithm to create objects. These objects are then classified using geometrical models and local descriptors. In order to evaluate the results, a new metric that combines both segmentation and classification results simultaneously is presented. The effects of voxel size and incorporation of RGB color and laser reflectance intensity on the classification results are also discussed. The method is evaluated on standard data sets using different metrics to demonstrate its efficacy.

  1. Use of circulation types classifications to evaluate AR4 climate models over the Euro-Atlantic region

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, M.A.; Casado, M.J. [Agencia Estatal de Meteorologia (AEMET), Madrid (Spain)

    2012-10-15

    This paper presents an evaluation of the multi-model simulations for the 4th Assessment Report of the Intergovernmental Panel on Climate Change (IPCC) in terms of their ability to simulate the ERA40 circulation types over the Euro-Atlantic region in winter season. Two classification schemes, k-means and SANDRA, have been considered to test the sensitivity of the evaluation results to the classification procedure. The assessment allows establishing different rankings attending spatial and temporal features of the circulation types. Regarding temporal characteristics, in general, all AR4 models tend to underestimate the frequency of occurrence. The best model simulating spatial characteristics is the UKMO-HadGEM1 whereas CCSM3, UKMO-HadGEM1 and CGCM3.1(T63) are the best simulating the temporal features, for both classification schemes. This result agrees with the AR4 models ranking obtained when having analysed the ability of the same AR4 models to simulate Euro-Atlantic variability modes. This study has proved the utility of applying such a synoptic climatology approach as a diagnostic tool for models' assessment. The ability of the models to properly reproduce the position of ridges and troughs and the frequency of synoptic patterns, will therefore improve our confidence in the response of models to future climate changes. (orig.)

  2. Evaluation of the Nuclear Medicine facilities in Minas Gerais state: quality control program of equipment

    International Nuclear Information System (INIS)

    Kubo, Tadeu Takao Almodovar; Biancardi, Rodrigo; Rocha, Adriana Marcia Guimaraes; Ferreira, Denia Romao; Silva, Franciele Aquiles Anjos; Assuncao, Jonathan Buenos Aires; Alves, Ederson Henrique; Almeida, Ana Flavia Batista; Alves, Nathalia Fernandes; Xavier, Faber Henrique Zacarias; Gontijo, Rodrigo Modesto Gadelha; Mamede, Marcelo; Universidade Federal de Minas Gerais

    2017-01-01

    With the reformulation of the CNEN-NN-3.05 standard in December 2013, Brazil's Nuclear Medicine (NMS) services have to perform a greater number of quality controls for SPECT and PET equipment. However, little is known about the reality of the quality control programs of these services regarding the application of the new standard. Thus, in this context, the objective of the present study was to evaluate the quality control program of MNSs in the state of Minas Gerais. All NMSs in the state of Minas Gerais were invited to participate in the project. Of these, 34.48% (20 facilities) agreed to participate in the project, 50.00% (29 facilities) did not respond to the invitation and 15.52%(9 facilities) declined their participation. Thus, as of November 2015, 20 SPECT and 2 PET/CT equipment were evaluated for the performance of the quality control tests recommended by the new CNEN standard. The phantoms required for the evaluation came from the Laboratory of Dosimetry and Quality Control of UFMG. Even with the deadlines set by CNEN for the implementation of the quality control program in the NMSs, more than 50% of the evaluated services did not implement the quality controls, and the absence of specific phantoms is the main reason for the failure. Among the problems found in the installations, the most critical were: collimators with no conditions of use in the clinical routine, linearity problems of the evaluated image and values of image uniformity superior to the limits of acceptance. Problems in the uniformity and linearity of the image found directly impacted the performance of other tests, such as spatial resolution, SPECT performance, among others. In a general way, the NMSs in the state of Minas Gerais evaluated with the present study are in clinical feasible conditions. (author)

  3. Evaluation of forest cover estimates for Haiti using supervised classification of Landsat data

    Science.gov (United States)

    Churches, Christopher E.; Wampler, Peter J.; Sun, Wanxiao; Smith, Andrew J.

    2014-08-01

    This study uses 2010-2011 Landsat Thematic Mapper (TM) imagery to estimate total forested area in Haiti. The thematic map was generated using radiometric normalization of digital numbers by a modified normalization method utilizing pseudo-invariant polygons (PIPs), followed by supervised classification of the mosaicked image using the Food and Agriculture Organization (FAO) of the United Nations Land Cover Classification System. Classification results were compared to other sources of land-cover data produced for similar years, with an emphasis on the statistics presented by the FAO. Three global land cover datasets (GLC2000, Globcover, 2009, and MODIS MCD12Q1), and a national-scale dataset (a land cover analysis by Haitian National Centre for Geospatial Information (CNIGS)) were reclassified and compared. According to our classification, approximately 32.3% of Haiti's total land area was tree covered in 2010-2011. This result was confirmed using an error-adjusted area estimator, which predicted a tree covered area of 32.4%. Standardization to the FAO's forest cover class definition reduces the amount of tree cover of our supervised classification to 29.4%. This result was greater than the reported FAO value of 4% and the value for the recoded GLC2000 dataset of 7.0%, but is comparable to values for three other recoded datasets: MCD12Q1 (21.1%), Globcover (2009) (26.9%), and CNIGS (19.5%). We propose that at coarse resolutions, the segmented and patchy nature of Haiti's forests resulted in a systematic underestimation of the extent of forest cover. It appears the best explanation for the significant difference between our results, FAO statistics, and compared datasets is the accuracy of the data sources and the resolution of the imagery used for land cover analyses. Analysis of recoded global datasets and results from this study suggest a strong linear relationship (R2 = 0.996 for tree cover) between spatial resolution and land cover estimates.

  4. Evaluating malaria case management at public health facilities in two provinces in Angola.

    Science.gov (United States)

    Plucinski, Mateusz M; Ferreira, Manzambi; Ferreira, Carolina Miguel; Burns, Jordan; Gaparayi, Patrick; João, Lubaki; da Costa, Olinda; Gill, Parambir; Samutondo, Claudete; Quivinja, Joltim; Mbounga, Eliane; de León, Gabriel Ponce; Halsey, Eric S; Dimbu, Pedro Rafael; Fortes, Filomeno

    2017-05-03

    Malaria accounts for the largest portion of healthcare demand in Angola. A pillar of malaria control in Angola is the appropriate management of malaria illness, including testing of suspect cases with rapid diagnostic tests (RDTs) and treatment of confirmed cases with artemisinin-based combination therapy (ACT). Periodic systematic evaluations of malaria case management are recommended to measure health facility readiness and adherence to national case management guidelines. Cross-sectional health facility surveys were performed in low-transmission Huambo and high-transmission Uíge Provinces in early 2016. In each province, 45 health facilities were randomly selected from among all public health facilities stratified by level of care. Survey teams performed inventories of malaria commodities and conducted exit interviews and re-examinations, including RDT testing, of a random selection of all patients completing outpatient consultations. Key health facility readiness and case management indicators were calculated adjusting for the cluster sampling design and utilization. Availability of RDTs or microscopy on the day of the survey was 71% (54-83) in Huambo and 85% (67-94) in Uíge. At least one unit dose pack of one formulation of an ACT (usually artemether-lumefantrine) was available in 83% (66-92) of health facilities in Huambo and 79% (61-90) of health facilities in Uíge. Testing rates of suspect malaria cases in Huambo were 30% (23-38) versus 69% (53-81) in Uíge. Overall, 28% (13-49) of patients with uncomplicated malaria, as determined during the re-examination, were appropriately treated with an ACT with the correct dose in Huambo, compared to 60% (42-75) in Uíge. Incorrect case management of suspect malaria cases was associated with lack of healthcare worker training in Huambo and ACT stock-outs in Uíge. The results reveal important differences between provinces. Despite similar availability of testing and ACT, testing and treatment rates were lower in

  5. CADASTRAL CLASSIFICATION OF THE LAND PLOTS IN UKRAINE

    Directory of Open Access Journals (Sweden)

    KIRICHEK Yu. O.

    2016-04-01

    Full Text Available Summary. Work concerns development of national system of classification of the land plots. The developed classification will allow to solve correctly a number of the corresponding cadastral, land management, estimated and other tasks. The analysis of classifications of lands, improvements and real estate in general is made. The created offers concerning creation of a new classification of the land plots in Ukraine. Today the Ukrainian real estate market has no single system that separates the system property groups, classes and types. This significantly complicates the work and can not fully be aware of the specific situation of real estate market. This task is designed to solve classification properties, it is used to transition from a diversity of individual properties to a limited number of classes of evaluation objects. The classification is different functional purpose (use facilities assessment, which determines the difference in value.

  6. Evaluation of {sup 18}F radioactive concentration in exhaust at cyclotron facility at Chosun University

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Cheol Ki; Jang, Han; Lee, Goung Jin [Dept. of Nuclear Engineering, Chsoun University, Gwangju (Korea, Republic of)

    2016-11-15

    the recent prevalence of PET examinations in Korea has led to an increase in the number of cyclotrons. the medical isotope 18F produced in most cyclotron facilities currently operating in Korea is emitted into the environment during the production of [{sup 18}F]FdG, a cancerdiagnosis reagent. the amount of [{sup 18}F]FdG synthesized determines the radioactive concentration of {sup 18}F in the exhaust. at some facilities, this amount temporarily exceeds the emission limit. In this study, we evaluated the {sup 18}F radioactivity concentration in the exhaust from the cyclotron facility at chosun university. the {sup 18}F radioactivity concentration was measured using an air sampler and a hPGe semiconductor detector. the measurements showed that the radioactive concentration of {sup 18}F in the exhaust at the cyclotron facility at Chosun university was the highest during [{sup 18}F]FdG synthesis but remained under the legal limit of 2,000 Bq m{sup -3}.

  7. Evaluation of replacement tritium facility (RTF) compliance with DOE safety goals using probabilistic consequence assessment methodology

    International Nuclear Information System (INIS)

    O'Kula, K.R.; East, J.M.; Moore, M.L.

    1993-01-01

    The Savannah River Site (SRS), operated by the Westinghouse Savannah River Company (WSRC) for the US Department of Energy (DOE), is a major center for the processing of nuclear materials for national defense, deep-space exploration, and medical treatment applications in the United States. As an integral part of the DOE's effort to modernize facilities, implement improved handling and processing technology, and reduce operational risk to the general public and onsite workers, transition of tritium processing at SRS from the Consolidated Tritium Facility to the Replacement Tritium Facility (RTF) began in 1993. To ensure that operation of new DOE facilities such as RTF present minimum involuntary and voluntary risks to the neighboring public and workers, indices of risk have been established to serve as target levels or safety goals of performance for assessing nuclear safety. These goals are discussed from a historical perspective in the initial part of this paper. Secondly, methodologies to quantify risk indices are briefly described. Lastly, accident, abnormal event, and normal operation source terms from RTF are evaluated for consequence assessment purposes relative to the safety targets

  8. Design of Test Facility to Evaluate Boric Acid Precipitation Following a LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Jeong-Kwan; Song, Yong-Jae [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The U.S.NRC has identified a concern that debris associated with generic safety issue (GSI) - 191 may affect the potential precipitation of boric acid due to one or more of the following phenomena: - Reducing mass transport (i.e. mixing) between the core and the lower plenum (should debris accumulate at the core inlet) - Reduced lower plenum volume (should debris settle in the lower plenum), and, - Increased potential for boric acid precipitation (BAP) in the core (should debris accumulate in suspension in the core) To address these BAP issues, KHNP is planning to conduct validation tests by constructing a BAP test facility. This paper describes the design of test facility to evaluate BAP following a LOCA. The design of BAP test facility has been developed by KHNP. To design the test facility, test requirements and success criteria were established, and scaling analysis of power-to-volume method, Ishii-Kataoka method, and hierarchical two-tiered method were investigated. The test section is composed of two fuel assemblies with half of full of prototypic FA height. All the fuel rods are heated by the electric power supplier. The BAP tests in the presence of debris, buffering agents, and boron will be performed following the test matrix.

  9. Evaluation of a 5-tier scheme proposed for classification of sequence variants using bioinformatic and splicing assay data

    DEFF Research Database (Denmark)

    Walker, Logan C; Whiley, Phillip J; Houdayer, Claude

    2013-01-01

    BRCA1 and 176 BRCA2 unique variants, from 77 publications. At least six independent reviewers from research and/or clinical settings comprehensively examined splicing assay methods and data reported for 22 variant assays of 21 variants in four publications, and classified the variants using the 5-tier......Splicing assays are commonly undertaken in the clinical setting to assess the clinical relevance of sequence variants in disease predisposition genes. A 5-tier classification system incorporating both bioinformatic and splicing assay information was previously proposed as a method to provide...... of results, and the lack of quantitative data for the aberrant transcripts. We propose suggestions for minimum reporting guidelines for splicing assays, and improvements to the 5-tier splicing classification system to allow future evaluation of its performance as a clinical tool....

  10. Evaluation of methods for seismic analysis of nuclear fuel reprocessing and fabrication facilities

    International Nuclear Information System (INIS)

    Arthur, D.F.; Dong, R.G.; Murray, R.C.; Nelson, T.A.; Smith, P.D.; Wight, L.H.

    1978-01-01

    Methods of seismic analysis for critical structures and equipment in nuclear fuel reprocessing plants (NFRPs) and mixed oxide fuel fabrication plants (MOFFPs) are evaluated. The purpose of this series of reports is to provide the NRC with a technical basis for assessing seismic analysis methods and for writing regulatory guides in which methods ensuring the safe design of nuclear fuel cycle facilities are recommended. The present report evaluates methods of analyzing buried pipes and wells, sloshing effects in large pools, earth dams, multiply supported equipment, pile foundations, and soil-structure interactions

  11. Ontologies vs. Classification Systems

    DEFF Research Database (Denmark)

    Madsen, Bodil Nistrup; Erdman Thomsen, Hanne

    2009-01-01

    What is an ontology compared to a classification system? Is a taxonomy a kind of classification system or a kind of ontology? These are questions that we meet when working with people from industry and public authorities, who need methods and tools for concept clarification, for developing meta...... data sets or for obtaining advanced search facilities. In this paper we will present an attempt at answering these questions. We will give a presentation of various types of ontologies and briefly introduce terminological ontologies. Furthermore we will argue that classification systems, e.g. product...... classification systems and meta data taxonomies, should be based on ontologies....

  12. Post-Occupancy Evaluation of a Mental Healthcare Facility Based on Staff Perceptions of Design Innovations.

    Science.gov (United States)

    Kalantari, Saleh; Snell, Robin

    2017-07-01

    This study was a post-occupancy evaluation (POE) to examine the effectiveness of three specific design innovations in a mental healthcare facility. In addition to collecting data about the impact of these specific designs, the study provides a model for the broader implementation of POE approaches in the mental healthcare context. POEs in general healthcare settings have been shown to lead to better work environments and better outcomes for patients. Despite growing evidence of the value provided by POE studies, the industry has been somewhat slow to adopt their regular use, in part due to unfamiliarity with the POE process. This is particularly true in mental healthcare contexts, where POE studies remain virtually nonexistent. In-depth interviews and a widely distributed, anonymous survey were used to collect hospital staff perceptions and feedback regarding the impact of specific design features. The hospital staff were quite enthusiastic about two of the design innovations studied here (a new wayfinding strategy and the use of vibrant colors in specific areas of the facility). The third innovation, open-style communication centers, elicited more mixed evaluations. The results include extensive hypothesis testing about the effects of each innovation as well as narrative discussions of their pros and cons. The study generated new knowledge about three specific mental healthcare design innovations and provides a model for the practical implementation of a POE approach in mental healthcare contexts. The results are particularly relevant for designers who are considering innovative strategies in future mental healthcare facilities.

  13. Generalized economic model for evaluating disposal costs at a low-level waste disposal facility

    International Nuclear Information System (INIS)

    Baird, R.D.; Rogers, V.C.

    1985-01-01

    An economic model is developed which can be used to evaluate cash flows associated with the development, operations, closure, and long-term maintenance of a proposed Low-Level Radioactive Waste disposal facility and to determine the unit disposal charges and unit surcharges which might result. The model includes the effects of nominal interest rate (rate of return on investment, or cost of capital), inflation rate, waste volume growth rate, site capacity, duration of various phases of the facility history, and the cash flows associated with each phase. The model uses standard discounted cash flow techniques on an after-tax basis to determine that unit disposal charge which is necessary to cover all costs and expenses and to generate an adequate rate of return on investment. It separately considers cash flows associated with post-operational activities to determine the required unit surcharge. The model is applied to three reference facilities to determine the respective unit disposal charges and unit surcharges, with various values of parameters. The sensitivity of the model results are evaluated for the unit disposal charge

  14. Economic evaluation of pharmacist-led medication reviews in residential aged care facilities.

    Science.gov (United States)

    Hasan, Syed Shahzad; Thiruchelvam, Kaeshaelya; Kow, Chia Siang; Ghori, Muhammad Usman; Babar, Zaheer-Ud-Din

    2017-10-01

    Medication reviews is a widely accepted approach known to have a substantial impact on patients' pharmacotherapy and safety. Numerous options to optimise pharmacotherapy in older people have been reported in literature and they include medication reviews, computerised decision support systems, management teams, and educational approaches. Pharmacist-led medication reviews are increasingly being conducted, aimed at attaining patient safety and medication optimisation. Cost effectiveness is an essential aspect of a medication review evaluation. Areas covered: A systematic searching of articles that examined the cost-effectiveness of medication reviews conducted in aged care facilities was performed using the relevant databases. Pharmacist-led medication reviews confer many benefits such as attainment of biomarker targets for improved clinical outcomes, and other clinical parameters, as well as depict concrete financial advantages in terms of decrement in total medication costs and associated cost savings. Expert commentary: The cost-effectiveness of medication reviews are more consequential than ever before. A critical evaluation of pharmacist-led medication reviews in residential aged care facilities from an economical aspect is crucial in determining if the time, effort, and direct and indirect costs involved in the review rationalise the significance of conducting medication reviews for older people in aged care facilities.

  15. Seismic analysis, evaluation and upgrade design for a nuclear facility exhaust stack building

    International Nuclear Information System (INIS)

    Malik, L.E.; Kabir, A.F.

    1991-01-01

    This paper reports on an exhaust stack building of a nuclear reactor facility with complex structural configuration that has been analyzed and evaluated for seismic forces. This building was built in the 1950's and had not been designed to resist seismic forces. A very rigorous analysis and evaluation program was implemented to minimize the costly retrofits required to upgrade the building to resist high seismic forces. The seismic evaluations were performed for the building in its as-is configuration, and as modified for several upgrade schemes. Soil-structure-interaction, base mat flexibility and the influence of the nearby reactor building have been considered in the seismic analyses. The rigorous analyses and evaluation enabled limited upgrades to qualify the stack building for the seismic forces

  16. Natural phenomena hazards evaluation of equipment and piping of Gaseous Diffusion Plant Uranium Enrichment Facility

    International Nuclear Information System (INIS)

    Singhal, M.K.; Kincaid, J.H.; Hammond, C.R.; Stockdale, B.I.; Walls, J.C.

    1995-01-01

    In support of the Gaseous Diffusion Plant Safety Analysis Report Upgrade program (GDP SARUP), a natural phenomena hazards evaluation was performed for the main process equipment and piping in the uranium enrichment buildings at Paducah and Portsmouth gaseous diffusion plants. In order to reduce the cost of rigorous analyses, the evaluation methodology utilized a graded approach based on an experience data base collected by SQUG/EPRI that contains information on the performance of industrial equipment and piping during past earthquakes. This method consisted of a screening walkthrough of the facility in combination with the use of engineering judgment and simple calculations. By using these screenings combined with evaluations that contain decreasing conservatism, reductions in the time and cost of the analyses were significant. A team of experienced seismic engineers who were trained in the use of the DOE SQUG/EPRI Walkdown Screening Material was essential to the success of this natural phenomena hazards evaluation

  17. Natural phenomena hazards evaluation of equipment and piping of Gaseous Diffusion Plant Uranium Enrichment Facility

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, M.K.; Kincaid, J.H.; Hammond, C.R.; Stockdale, B.I.; Walls, J.C. [Oak Ridge National Lab., TN (United States). Technical Programs and Services; Brock, W.R.; Denton, D.R. [Lockheed Martin Energy Systems, Inc., Oak Ridge, TN (United States)

    1995-12-31

    In support of the Gaseous Diffusion Plant Safety Analysis Report Upgrade program (GDP SARUP), a natural phenomena hazards evaluation was performed for the main process equipment and piping in the uranium enrichment buildings at Paducah and Portsmouth gaseous diffusion plants. In order to reduce the cost of rigorous analyses, the evaluation methodology utilized a graded approach based on an experience data base collected by SQUG/EPRI that contains information on the performance of industrial equipment and piping during past earthquakes. This method consisted of a screening walkthrough of the facility in combination with the use of engineering judgment and simple calculations. By using these screenings combined with evaluations that contain decreasing conservatism, reductions in the time and cost of the analyses were significant. A team of experienced seismic engineers who were trained in the use of the DOE SQUG/EPRI Walkdown Screening Material was essential to the success of this natural phenomena hazards evaluation.

  18. Defense In-Depth Accident Analysis Evaluation of Tritium Facility Bldgs. 232-H, 233-H, and 234-H

    International Nuclear Information System (INIS)

    Blanchard, A.

    1999-01-01

    'The primary purpose of this report is to document a Defense-in-Depth (DID) accident analysis evaluation for Department of Energy (DOE) Savannah River Site (SRS) Tritium Facility Buildings 232-H, 233-H, and 234-H. The purpose of a DID evaluation is to provide a more realistic view of facility radiological risks to the offsite public than the bounding deterministic analysis documented in the Safety Analysis Report, which credits only Safety Class items in the offsite dose evaluation.'

  19. Bioaerosol releases from compost facilities: Evaluating passive and active source terms at a green waste facility for improved risk assessments

    Science.gov (United States)

    Taha, M. P. M.; Drew, G. H.; Longhurst, P. J.; Smith, R.; Pollard, S. J. T.

    The passive and active release of bioaerosols during green waste composting, measured at source is reported for a commercial composting facility in South East (SE) England as part of a research programme focused on improving risk assessments at composting facilities. Aspergillus fumigatus and actinomycetes concentrations of 9.8-36.8×10 6 and 18.9-36.0×10 6 cfu m -3, respectively, measured during the active turning of green waste compost, were typically 3-log higher than previously reported concentrations from static compost windrows. Source depletion curves constructed for A. fumigatus during compost turning and modelled using SCREEN3 suggest that bioaerosol concentrations could reduce to background concentrations of 10 3 cfu m -3 within 100 m of this site. Authentic source term data produced from this study will help to refine the risk assessment methodologies that support improved permitting of compost facilities.

  20. Evaluating an ensemble classification approach for crop diversityverification in Danish greening subsidy control

    DEFF Research Database (Denmark)

    Chellasamy, Menaka; Ferre, Ty; Greve, Mogens Humlekrog

    2016-01-01

    Beginning in 2015, Danish farmers are obliged to meet specific crop diversification rules based on total land area and number of crops cultivated to be eligible for new greening subsidies. Hence, there is a need for the Danish government to extend their subsidy control system to verify farmers......’ declarations to war-rant greening payments under the new crop diversification rules. Remote Sensing (RS) technology has been used since 1992 to control farmers’ subsidies in Denmark. However, a proper RS-based approach is yet to be finalised to validate new crop diversity requirements designed for assessing...... compliance under the recent subsidy scheme (2014–2020); This study uses an ensemble classification approach(proposed by the authors in previous studies) for validating the crop diversity requirements of the new rules. The approach uses a neural network ensemble classification system with bi-temporal (spring...

  1. ACOUSTIC CLASSIFICATION OF FRESHWATER FISH SPECIES USING ARTIFICIAL NEURAL NETWORK: EVALUATION OF THE MODEL PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Zulkarnaen Fahmi

    2013-06-01

    Full Text Available Hydroacoustic techniques are a valuable tool for the stock assessments of many fish species. Nonetheless, such techniques are limited by problems of species identification. Several methods and techniques have been used in addressing the problem of acoustic identification species and one of them is Artificial Neural Networks (ANNs. In this paper, Back propagation (BP and Multi Layer Perceptron (MLP of the Artificial Neural Network were used to classify carp (Cyprinus carpio, tilapia (Oreochromis niloticus, and catfish (Pangasius hypothalmus. Classification was done using a set of descriptors extracted from the acoustic data records, i.e. Volume Back scattering (Sv, Target Strength (TS, Area Back scattering Strength, Skewness, Kurtosis, Depth, Height and Relative altitude. The results showed that the Multi Layer Perceptron approach performed better than the Back propagation. The classification rates was 85.7% with the multi layer perceptron (MLP compared to 84.8% with back propagation (BP ANN.

  2. Feelings of nurses in the reception and risk classification evaluation in the emergency room

    Directory of Open Access Journals (Sweden)

    Andressa Midori Sakai

    2016-05-01

    Full Text Available Objective: to reveal feelings of nurses who host with risk assessment and classification in an emergency room of a pubic hospital. Methods: it is a qualitative research approach with 12 nurses interviewed. The data were analyzed, categorized and discussed according to the theoretical framework of work psychodynamics. Results: the nurses expressed feelings of satisfaction in meeting the user needs assistance. They reported feeling as fear, stress and fatigue due to the sharp pace of work, gaps in health care network and situations of violence. They highlighted coping strategies to reduce the burden of this assignment, how to share the completion of the screening with the nursing staff. Conclusion: the host with risk assessment and classification favors the autonomy of nurses and provide greater accountability to this professional users, but the limitations of available resources to solve the complaint of patients generate physical and psychological burden to this worker.

  3. Feelings of nurses in the reception and risk classification evaluation in the emergency room

    Directory of Open Access Journals (Sweden)

    Andressa Midori Sakai

    2016-01-01

    Full Text Available Objective: to reveal feelings of nurses who host with risk assessment and classification in an emergency room of a pubic hospital. Methods: it is a qualitative research approach with 12 nurses interviewed. The data were analyzed, categorized and discussed according to the theoretical framework of work psychodynamics. Results: the nurses expressed feelings of satisfaction in meeting the user needs assistance. They reported feeling as fear, stress and fatigue due to the sharp pace of work, gaps in health care network and situations of violence. They highlighted coping strategies to reduce the burden of this assignment, how to share the completion of the screening with the nursing staff. Conclusion: the host with risk assessment and classification favors the autonomy of nurses and provide greater accountability to this professional users, but the limitations of available resources to solve the complaint of patients generate physical and psychological burden to this worker.

  4. Evaluation Methodology between Globalization and Localization Features Approaches for Skin Cancer Lesions Classification

    Science.gov (United States)

    Ahmed, H. M.; Al-azawi, R. J.; Abdulhameed, A. A.

    2018-05-01

    Huge efforts have been put in the developing of diagnostic methods to skin cancer disease. In this paper, two different approaches have been addressed for detection the skin cancer in dermoscopy images. The first approach uses a global method that uses global features for classifying skin lesions, whereas the second approach uses a local method that uses local features for classifying skin lesions. The aim of this paper is selecting the best approach for skin lesion classification. The dataset has been used in this paper consist of 200 dermoscopy images from Pedro Hispano Hospital (PH2). The achieved results are; sensitivity about 96%, specificity about 100%, precision about 100%, and accuracy about 97% for globalization approach while, sensitivity about 100%, specificity about 100%, precision about 100%, and accuracy about 100% for Localization Approach, these results showed that the localization approach achieved acceptable accuracy and better than globalization approach for skin cancer lesions classification.

  5. Value of real-time shear wave elastography in evaluating classification of liver fibrosis: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    WU Yue

    2017-09-01

    Full Text Available ObjectiveTo investigate the diagnostic value of real-time shear wave elastography (SWE technique in evaluating classification of liver fibrosis. MethodsPubMed, CNKI, CBM, VIP, and Wanfang Data were searched for Chinese and English articles on SWE for evaluating classification of liver fibrosis published from January 2010 to December 2016, and these articles were screened and evaluated. Meta-disc 1.4 software was used for the meta-analysis of the data in the articles included. ResultsA total of 11 English articles were included, with 1560 cases in total. In the ≥F2 group, SWE had a pooled sensitivity of 0.85 (95% confidence interval [CI]:0.82-0.87, a specificity of 0.79 (95%CI:0.76-0.82, and a diagnostic odds ratio (DOR of 30.81 (95%CI: 16.55-57.34. In the ≥F3 group, SWE had a pooled sensitivity of 0.87 (95%CI:0.84-0.91, a specificity of 0.84 (95%CI:0.82-0.87, and a DOR of 41.45 (95%CI:18.25-94.45. In the F4 group, SWE had a pooled sensitivity of 0.88 (95%CI:0.83-0.91, a specificity of 0.91 (95%CI:0.89-092, and a DOR of 67.18 (95%CI:30.03-150.31. The areas under the receiver operating characteristic curve for these three groups were 0.914 7, 0.922 3, and 0.952 0, respectively. ConclusionSWE has a high diagnostic value in evaluating the classification of liver fibrosis and can be used to determine liver fibrosis stage in clinical practice.

  6. Synoptic-climatological evaluation of the classifications of atmospheric circulation patterns over Europe

    Czech Academy of Sciences Publication Activity Database

    Huth, Radan; Beck, Ch.; Kučerová, Monika

    2016-01-01

    Roč. 36, č. 7 (2016), s. 2710-2726 ISSN 0899-8418 R&D Projects: GA ČR(CZ) GPP209/12/P811; GA MŠk OC 115 Institutional support: RVO:68378289 Keywords : circulation types * classification * synoptic climatology * COST733 Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 3.760, year: 2016 http://onlinelibrary.wiley.com/doi/10.1002/joc.4546/full

  7. Calculation of parameters for inspection planning and evaluation: low enriched uranium conversion and fuel fabrication facilities

    International Nuclear Information System (INIS)

    Reardon, P.T.; Mullen, M.F.; Harms, N.L.

    1981-02-01

    As part of Task C.35 (Calculation of Parameters for Inspection Planning and Evaluation) of the US Program of Technical Assistance to IAEA Safeguards, Pacific Northwest Laboratory has performed some quantitative analyses of IAEA inspection activities at low-enriched uranium (LEU) conversion and fuel fabrication facilities. This report presents the results and conclusions of those analyses. Implementation of IAEA safeguards at LEU conversion and fuel fabrication facilities must take into account a variety of practical problems and constraints. One of the key concerns is the problem of flow verification, especially product verification. The objective of this report is to help put the problem of flow verification in perspective by presenting the results of some specific calculations of inspection effort and probability of detection for various product measurement strategies. In order to provide quantitative information about the advantages and disadvantages of the various strategies, eight specific cases were examined

  8. Methodology to evaluate the site standard seismic motion to a nuclear facility

    International Nuclear Information System (INIS)

    Soares, W.A.

    1983-01-01

    For the seismic design of nuclear facilities, the input motion is normally defined by the predicted maximum ground horizontal acceleration and the free field ground response spectrum. This spectrum is computed on the basis of records of strong motion earthquakes. The pair maximum acceleration-response spectrum is called the site standard seismic motion. An overall view of the subjects involved in the determination of the site standard seismic motion to a nuclear facility is presented. The main topics discussed are: basic principles of seismic instrumentation; dynamic and spectral concepts; design earthquakes definitions; fundamentals of seismology; empirical curves developed from prior seismic data; available methodologies and recommended procedures to evaluate the site standard seismic motion. (Author) [pt

  9. Evaluation of protection factor of respiratory protective equipment using indigenously developed protection factor test facility

    International Nuclear Information System (INIS)

    Patkulkar, D.S.; Ganesh, G.; Tripathi, R.M.

    2018-01-01

    Assigned protection factor (APF) is an indicator representing effectiveness of a respirator and it provides workplace level of respiratory protection for workers in providing protection against exposure to airborne contaminants Occupational Safety and Health Administration (OSHA) specifies 'Respirator APF' and 'Maximum Use Concentration' (MUC - a term derived using APF) shall be an integral part of Respirator Protection Standard. MUC establishes the maximum airborne concentration of a contaminant in which a respirator with a given APF may be used. The use of particulate respirators such as half face mask, full face mask and powered air purifying respirators is essential for radioactive jobs in nuclear facilities to prevent any intake of radionuclide. With this impetus, the Protection Factor Test Facility (PFTF) for testing and evaluation of respiratory protective equipment meeting relevant applicable standards was designed, fabricated and installed in Respiratory Protective Equipment Laboratory of Health Physics Division

  10. An evaluation related to the effect of strategic facility management on choice of medical tourism destination

    Directory of Open Access Journals (Sweden)

    Tarcan Ertugrul

    2015-01-01

    Full Text Available This study based on literature review aims to evaluate and emphasize the affect of the strategic facility management (SFM on choice of medical tourism destination. Medical Tourism, which ranges from the health care services involving a cure to the wellness services involving no specific health trouble to pleasure and amusement services, is one of the most growing sectors in the world. Cost and quality of medical services are among the main reasons for the choice of destination. Strategic facility management has a positive correlation on the levels of quality, cost and customer satisfaction. Thus medical tourism and destination managers should take into account of the potential advantages of value creation offered through SFM in order to be chosen by customers (stakeholders.

  11. When machine vision meets histology: A comparative evaluation of model architecture for classification of histology sections.

    Science.gov (United States)

    Zhong, Cheng; Han, Ju; Borowsky, Alexander; Parvin, Bahram; Wang, Yunfu; Chang, Hang

    2017-01-01

    Classification of histology sections in large cohorts, in terms of distinct regions of microanatomy (e.g., stromal) and histopathology (e.g., tumor, necrosis), enables the quantification of tumor composition, and the construction of predictive models of genomics and clinical outcome. To tackle the large technical variations and biological heterogeneities, which are intrinsic in large cohorts, emerging systems utilize either prior knowledge from pathologists or unsupervised feature learning for invariant representation of the underlying properties in the data. However, to a large degree, the architecture for tissue histology classification remains unexplored and requires urgent systematical investigation. This paper is the first attempt to provide insights into three fundamental questions in tissue histology classification: I. Is unsupervised feature learning preferable to human engineered features? II. Does cellular saliency help? III. Does the sparse feature encoder contribute to recognition? We show that (a) in I, both Cellular Morphometric Feature and features from unsupervised feature learning lead to superior performance when compared to SIFT and [Color, Texture]; (b) in II, cellular saliency incorporation impairs the performance for systems built upon pixel-/patch-level features; and (c) in III, the effect of the sparse feature encoder is correlated with the robustness of features, and the performance can be consistently improved by the multi-stage extension of systems built upon both Cellular Morphmetric Feature and features from unsupervised feature learning. These insights are validated with two cohorts of Glioblastoma Multiforme (GBM) and Kidney Clear Cell Carcinoma (KIRC). Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Study on scenario evaluation methodology for decommissioning nuclear facilities using fuzzy logic

    International Nuclear Information System (INIS)

    Matsuhashi, Kazuya; Yanagihara, Satoshi

    2015-01-01

    Since there are many scenarios of the process from start to completion of a decommissioning project, it is important to study scenarios of decommissioning by evaluating such properties as safety, cost, and technology. An optimum scenario with the highest feasibility in accordance with the facility and environmental conditions should be selected on the basis of the results of the study. For analyzing a scenario of decommissioning, we prepared structured work packages by using the work breakdown structures (WBS) method together with qualitative evaluation of the technologies being applied to work packages located at the bottom (the third level) of the WBS. A calculation model was constructed to evaluate the feasibility of a scenario where fuzzy logic is applied to derive a score of technology performance and TOPSIS is applied for getting a feasibility grade of the scenario from technical performance scoring. As a case study, the model was applied to the debris removal scenario of Fukushima Daiichi Nuclear Power Plant to confirm its applicability. Two scenarios, underwater and in-air debris removal cases, were characterized by extracting the work packages with the lowest feasibility and by obtaining total average scores of the scenarios. It is confirmed that the methodology developed is useful for the scenario evaluation of decommissioning nuclear facilities. (author)

  13. ESF [Exploratory Shaft Facility] impact evaluation report: Volume 1, Final report

    International Nuclear Information System (INIS)

    1985-08-01

    This report assesses the impacts of integrating an Exploratory Shaft Facility (ESF) with a high-level nuclear waste repository in salt. A general repository subsurface design is described which complies with the Mine Safety and Health Administration regulations for gassy metal and non-metal mines. This design is combined with the ESF into a site-specific subsurface layout with associated shafts and surface facilities for each of seven sites. An evaluation to identify integration impacts is described for two specific ESF configurations (Cases 1 and 2) for each of the seven sites. These configurations are an ESF which uses two of the full size repository shafts, and an ESF with one 10-ft and one 22-ft diameter shaft. An evaluation of an ESF configuration (Case 3) with two 12-ft diameter shafts at three of the seven sites is also described. These sites are Deaf Smith, Davis Canyon, and Richton Dome. A fourth evaluation (Case 4) for the Deaf Smith site only, addresses a ''fast track'' subsurface development plan to allow waste emplacement by 1998. A fifth evaluation (Case 5), provides site-specific ES locations, for the three sites included in Case 3, which are supportive of a shaft siting study prepared by ONWI

  14. FOAM FORMATION IN THE SALTSTONE PRODUCTION FACILITY: EVALUATION OF SOURCES AND MITIGATION

    Energy Technology Data Exchange (ETDEWEB)

    Cozzi, A.

    2011-01-18

    The Saltstone Production Facility receives waste from Tank 50H for treatment. Influents into Tank 50H include the Effluent Treatment Project waste concentrate, H-Canyon low activity waste and General Purpose Evaporator bottoms, Modular Caustic Side Solvent Extraction Unit decontaminated salt solution, and salt solution from the Deliquification, Dissolution and Adjust campaign. Using the Waste Characterization System (WCS), this study tracks the relative amounts of each influent into Tank 50H, as well as the total content of Tank 50H, in an attempt to identify the source of foaming observed in the Saltstone Production Facility hopper. Saltstone has been using antifoam as part of routine processing with the restart of the facility in December 2006. It was determined that the maximum admix usage in the Saltstone Production Facility, both antifoam and set retarder, corresponded with the maximum concentration of H-Canyon low activity waste in Tank 50H. This paper also evaluates archived salt solutions from Waste Acceptance Criteria analysis for propensity to foam and the antifoam dosage required to mitigate foaming. It was determined that Effluent Treatment Project contributed to the expansion factor (foam formation) and General Purpose Evaporator contributed to foaminess (persistence). It was also determined that undissolved solids contribute to foam persistence. It was shown that additions of Dow Corning Q2-1383a antifoam reduced both the expansion factor and foaminess of salt solutions. The evaluation of foaming in the grout hopper during the transition from water to salt solution indicated that higher water-to-premix ratios tended to produce increased foaming. It was also shown that additions of Dow Corning Q2-1383a antifoam reduced foam formation and persistence.

  15. Process evaluation of communitisation programme in public sector health facilities, Mokokchung district, Nagaland, 2015

    Directory of Open Access Journals (Sweden)

    Aonungdok Tushi

    2017-01-01

    Full Text Available Background: Public sector health facilities were poorly managed due to a history of conflict in Nagaland, India. Government of Nagaland introduced “Nagaland Communitisation of Public Institutions and Services Act” in 2002. Main objectives of the evaluation were to review the functioning of Health Center Managing Committees (HCMCs, deliver health services in the institutions managed by HCMC, identify strengths as well as challenges perceived by HCMC members in the rural areas of Mokokchung district, Nagaland. Materials and Methods: The evaluation was made using input, process and output indicators. A doctor, the HCMC Chairman and one member from each of the three community health centers (CHC and four primary health centers (PHC were surveyed using a semi-structured questionnaire and an in-depth interview guide. Proportions for quantitative data were computed and key themes from the same were identified. Results: Overall; the infrastructure, equipment and outpatient/inpatient service availability was satisfactory. There was a lack of funds and shortage of doctors, drugs as well as laboratory facilities. HCMCs were in place and carried out administrative activities. HCMCs felt ownership, mobilized community contributions and managed human resources. HCMC members had inadequate funds for their transport and training. They faced challenges in service delivery due to political interference and lack of adequate human, material, financial resources. Conclusions: Communitisation program was operational in the district. HCMC members felt the ownership of health facilities. Administrative, political support and adequate funds from the government are needed for effective functioning of HCMCs and optimal service delivery in public sector facilities.

  16. Evaluation of the Chinese Fine Spatial Resolution Hyperspectral Satellite TianGong-1 in Urban Land-Cover Classification

    Directory of Open Access Journals (Sweden)

    Xueke Li

    2016-05-01

    Full Text Available The successful launch of the Chinese high spatial resolution hyperspectral satellite TianGong-1 (TG-1 opens up new possibilities for applications of remotely-sensed satellite imagery. One of the main goals of the TG-1 mission is to provide observations of surface attributes at local and landscape spatial scales to map urban land cover accurately using the hyperspectral technique. This study attempted to evaluate the TG-1 datasets for urban feature analysis, using existing data over Beijing, China, by comparing the TG-1 (with a spatial resolution of 10 m to EO-1 Hyperion (with a spatial resolution of 30 m. The spectral feature of TG-1 was first analyzed and, thus, finding out optimal hyperspectral wavebands useful for the discrimination of urban areas. Based on this, the pixel-based maximum likelihood classifier (PMLC, pixel-based support vector machine (PSVM, hybrid maximum likelihood classifier (HMLC, and hybrid support vector machine (HSVM were implemented, as well as compared in the application of mapping urban land cover types. The hybrid classifier approach, which integrates the pixel-based classifier and the object-based segmentation approach, was demonstrated as an effective alternative to the conventional pixel-based classifiers for processing the satellite hyperspectral data, especially the fine spatial resolution data. For TG-1 imagery, the pixel-based urban classification was obtained with an average overall accuracy of 89.1%, whereas the hybrid urban classification was obtained with an average overall accuracy of 91.8%. For Hyperion imagery, the pixel-based urban classification was obtained with an average overall accuracy of 85.9%, whereas the hybrid urban classification was obtained with an average overall accuracy of 86.7%. Overall, it can be concluded that the fine spatial resolution satellite hyperspectral data TG-1 is promising in delineating complex urban scenes, especially when using an appropriate classifier, such as the

  17. VISA: a method for evaluating the performance of integrated safeguards systems at nuclear facilities

    International Nuclear Information System (INIS)

    Donnelly, H.; Fullwood, R.; Glancy, J.

    1977-06-01

    This is the second volume of a two volume report on the VISA method for evaluating safeguards at fixed-site facilities. This volume contains appendices that support the description of the VISA concept and the initial working version of the method, VISA-1, presented in Volume I. The information is separated into four appendices, each describing details of one of the four analysis modules that comprise the analysis sections of the method. The first appendix discusses Path Analysis methodology, applies it to a Model Fuel Facility, and describes the computer codes that are being used. Introductory material on Path Analysis given in Chapter 3.2.1 and Chapter 4.2.1 of Volume I. The second appendix deals with Detection Analysis, specifically the schemes used in VISA-1 for classifying adversaries and the methods proposed for evaluating individual detection mechanisms in order to build the data base required for detection analysis. Examples of evaluations on identity-access systems, SNM portal monitors, and intrusion devices are provided. The third appendix describes the Containment Analysis overt-segment path ranking, the Monte Carlo engagement model, the network simulation code, the delay mechanism data base, and the results of a sensitivity analysis. The last appendix presents general equations used in Interruption Analysis for combining covert-overt segments and compares them with equations given in Volume I, Chapter 3

  18. Quantitative evaluation of variations in rule-based classifications of land cover in urban neighbourhoods using WorldView-2 imagery

    Science.gov (United States)

    Belgiu, Mariana; ǎguţ, Lucian, , Dr; Strobl, Josef

    2014-01-01

    The increasing availability of high resolution imagery has triggered the need for automated image analysis techniques, with reduced human intervention and reproducible analysis procedures. The knowledge gained in the past might be of use to achieving this goal, if systematically organized into libraries which would guide the image analysis procedure. In this study we aimed at evaluating the variability of digital classifications carried out by three experts who were all assigned the same interpretation task. Besides the three classifications performed by independent operators, we developed an additional rule-based classification that relied on the image classifications best practices found in the literature, and used it as a surrogate for libraries of object characteristics. The results showed statistically significant differences among all operators who classified the same reference imagery. The classifications carried out by the experts achieved satisfactory results when transferred to another area for extracting the same classes of interest, without modification of the developed rules.

  19. Molecular phylogenetic evaluation of classification and scenarios of character evolution in calcareous sponges (Porifera, Class Calcarea.

    Directory of Open Access Journals (Sweden)

    Oliver Voigt

    Full Text Available Calcareous sponges (Phylum Porifera, Class Calcarea are known to be taxonomically difficult. Previous molecular studies have revealed many discrepancies between classically recognized taxa and the observed relationships at the order, family and genus levels; these inconsistencies question underlying hypotheses regarding the evolution of certain morphological characters. Therefore, we extended the available taxa and character set by sequencing the complete small subunit (SSU rDNA and the almost complete large subunit (LSU rDNA of additional key species and complemented this dataset by substantially increasing the length of available LSU sequences. Phylogenetic analyses provided new hypotheses about the relationships of Calcarea and about the evolution of certain morphological characters. We tested our phylogeny against competing phylogenetic hypotheses presented by previous classification systems. Our data reject the current order-level classification by again finding non-monophyletic Leucosolenida, Clathrinida and Murrayonida. In the subclass Calcinea, we recovered a clade that includes all species with a cortex, which is largely consistent with the previously proposed order Leucettida. Other orders that had been rejected in the current system were not found, but could not be rejected in our tests either. We found several additional families and genera polyphyletic: the families Leucascidae and Leucaltidae and the genus Leucetta in Calcinea, and in Calcaronea the family Amphoriscidae and the genus Ute. Our phylogeny also provided support for the vaguely suspected close relationship of several members of Grantiidae with giantortical diactines to members of Heteropiidae. Similarly, our analyses revealed several unexpected affinities, such as a sister group relationship between Leucettusa (Leucaltidae and Leucettidae and between Leucascandra (Jenkinidae and Sycon carteri (Sycettidae. According to our results, the taxonomy of Calcarea is in

  20. Evaluation of feature selection algorithms for classification in temporal lobe epilepsy based on MR images

    Science.gov (United States)

    Lai, Chunren; Guo, Shengwen; Cheng, Lina; Wang, Wensheng; Wu, Kai

    2017-02-01

    It's very important to differentiate the temporal lobe epilepsy (TLE) patients from healthy people and localize the abnormal brain regions of the TLE patients. The cortical features and changes can reveal the unique anatomical patterns of brain regions from the structural MR images. In this study, structural MR images from 28 normal controls (NC), 18 left TLE (LTLE), and 21 right TLE (RTLE) were acquired, and four types of cortical feature, namely cortical thickness (CTh), cortical surface area (CSA), gray matter volume (GMV), and mean curvature (MCu), were explored for discriminative analysis. Three feature selection methods, the independent sample t-test filtering, the sparse-constrained dimensionality reduction model (SCDRM), and the support vector machine-recursive feature elimination (SVM-RFE), were investigated to extract dominant regions with significant differences among the compared groups for classification using the SVM classifier. The results showed that the SVM-REF achieved the highest performance (most classifications with more than 92% accuracy), followed by the SCDRM, and the t-test. Especially, the surface area and gray volume matter exhibited prominent discriminative ability, and the performance of the SVM was improved significantly when the four cortical features were combined. Additionally, the dominant regions with higher classification weights were mainly located in temporal and frontal lobe, including the inferior temporal, entorhinal cortex, fusiform, parahippocampal cortex, middle frontal and frontal pole. It was demonstrated that the cortical features provided effective information to determine the abnormal anatomical pattern and the proposed method has the potential to improve the clinical diagnosis of the TLE.

  1. An Evaluation of Facility Maintenance and Repair Strategies of Select Companies

    National Research Council Canada - National Science Library

    Sharp, Christopher

    2002-01-01

    ...) with the benefits derived from those facilities. This thesis documents how a selection of companies implemented that balance by determining their facilities requirements based on their chosen facility condition level and how they then allocated funds...

  2. Utility industry evaluation of the metal fuel facility and metal fuel performance for liquid metal reactors

    International Nuclear Information System (INIS)

    Burstein, S.; Gibbons, J.P.; High, M.D.; O'Boyle, D.R.; Pickens, T.A.; Pilmer, D.F.; Tomonto, J.R.; Weinberg, C.J.

    1990-02-01

    A team of utility industry representatives evaluated the liquid metal reactor metal fuel process and facility conceptual design being developed by Argonne National Laboratory (ANL) under Department of Energy sponsorship. The utility team concluded that a highly competent ANL team was making impressive progress in developing high performance advanced metal fuel and an economic processing and fabrication technology. The utility team concluded that the potential benefits of advanced metal fuel justified the development program, but that, at this early stage, there are considerable uncertainties in predicting the net overall economic benefit of metal fuel. Specific comments and recommendations are provided as a contribution towards enhancing the development program. 6 refs

  3. Evaluation of the impact and the releases of operating nuclear facilities

    International Nuclear Information System (INIS)

    2005-01-01

    The monitoring of nuclear installations releases, the associated impacts evaluation and the radiation monitoring of the environment are of an increase interest since the last ten years. Theses two days, organized by the environment section of the SFRP (French Society of Radiation Protection), aim to discuss the following topics: the development of the methods to improve radioactive elements and toxic substances releases in the environment; the structure of the environment control and the objectives of this control; the association of the local actors to the releases monitoring and to the environment control; the perspectives of evolution in matter of nuclear facilities releases management. (A.L.B.)

  4. Source term evaluation for accident transients in the experimental fusion facility ITER

    Energy Technology Data Exchange (ETDEWEB)

    Virot, F.; Barrachin, M.; Cousin, F. [IRSN, BP3-13115, Saint Paul lez Durance (France)

    2015-03-15

    We have studied the transport and chemical speciation of radio-toxic and toxic species for an event of water ingress in the vacuum vessel of experimental fusion facility ITER with the ASTEC code. In particular our evaluation takes into account an assessed thermodynamic data for the beryllium gaseous species. This study shows that deposited beryllium dusts of atomic Be and Be(OH){sub 2} are formed. It also shows that Be(OT){sub 2} could exist in some conditions in the drain tank. (authors)

  5. Preliminary geotechnical evaluation of deep borehole facilities for nuclear waste disposal in shales

    International Nuclear Information System (INIS)

    Nataraj, M.S.; New Orleans Univ., LA

    1991-01-01

    This study is concerned with a preliminary engineering evaluation of borehole facilities for nuclear waste disposal in shales. Some of the geotechnical properties of Pierre, Rhinestreet, and typical illite shale have been collected. The influence of a few geotechnical properties on strength and deformation of host material is briefly examined. It appears that Pierre shale is very unstable and requires support to prevent collapse. Typical illite shale is more stable than Rhinestreet shale, although it undergoes relatively more deformation. 16 refs., 5 figs., 3 tabs

  6. Evaluating Commercial and Private Cloud Services for Facility-Scale Geodetic Data Access, Analysis, and Services

    Science.gov (United States)

    Meertens, C. M.; Boler, F. M.; Ertz, D. J.; Mencin, D.; Phillips, D.; Baker, S.

    2017-12-01

    UNAVCO, in its role as a NSF facility for geodetic infrastructure and data, has succeeded for over two decades using on-premises infrastructure, and while the promise of cloud-based infrastructure is well-established, significant questions about suitability of such infrastructure for facility-scale services remain. Primarily through the GeoSciCloud award from NSF EarthCube, UNAVCO is investigating the costs, advantages, and disadvantages of providing its geodetic data and services in the cloud versus using UNAVCO's on-premises infrastructure. (IRIS is a collaborator on the project and is performing its own suite of investigations). In contrast to the 2-3 year time scale for the research cycle, the time scale of operation and planning for NSF facilities is for a minimum of five years and for some services extends to a decade or more. Planning for on-premises infrastructure is deliberate, and migrations typically take months to years to fully implement. Migrations to a cloud environment can only go forward with similar deliberate planning and understanding of all costs and benefits. The EarthCube GeoSciCloud project is intended to address the uncertainties of facility-level operations in the cloud. Investigations are being performed in a commercial cloud environment (Amazon AWS) during the first year of the project and in a private cloud environment (NSF XSEDE resource at the Texas Advanced Computing Center) during the second year. These investigations are expected to illuminate the potential as well as the limitations of running facility scale production services in the cloud. The work includes running parallel equivalent cloud-based services to on premises services and includes: data serving via ftp from a large data store, operation of a metadata database, production scale processing of multiple months of geodetic data, web services delivery of quality checked data and products, large-scale compute services for event post-processing, and serving real time data

  7. Evaluation and integration of disparate classification systems for clefts of the lip

    Directory of Open Access Journals (Sweden)

    Kathie H Wang

    2014-05-01

    Full Text Available Orofacial clefting is a common birth defect with wide phenotypic variability. Many systems have been developed to classify cleft patterns to facilitate diagnosis, management, surgical treatment, and research. In this review, we examine the rationale for different existing classification schemes and determine their inter-relationships, as well as strengths and deficiencies for subclassification of clefts of the lip. The various systems differ in how they describe and define attributes of cleft lip phenotypes. Application and analysis of the cleft lip classifications reveal discrepancies that may result in errors when comparing studies that use different systems. These inconsistencies in terminology, variable levels of subclassification, and ambiguity in some descriptions may confound analyses and impede further research aimed at understanding the genetics and etiology of clefts, development of effective treatment options for patients, as well as cross-institutional comparisons of outcome measures. Identification and reconciliation of discrepancies among existing systems is the first step towards creating a common standard to allow for a more explicit interpretation that will ultimately lead to a better understanding of the causes and manifestations of phenotypic variations in clefting.

  8. Classifying Classifications

    DEFF Research Database (Denmark)

    Debus, Michael S.

    2017-01-01

    This paper critically analyzes seventeen game classifications. The classifications were chosen on the basis of diversity, ranging from pre-digital classification (e.g. Murray 1952), over game studies classifications (e.g. Elverdam & Aarseth 2007) to classifications of drinking games (e.g. LaBrie et...... al. 2013). The analysis aims at three goals: The classifications’ internal consistency, the abstraction of classification criteria and the identification of differences in classification across fields and/or time. Especially the abstraction of classification criteria can be used in future endeavors...... into the topic of game classifications....

  9. Experimental performance evaluation of two stack sampling systems in a plutonium facility

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.

    1992-04-01

    The evaluation of two routine stack sampling systems at the Z-Plant plutonium facility operated by Rockwell International for USERDA is part of a larger study, sponsored by Rockwell and conducted by Battelle, Pacific Northwest Laboratories, of gaseous effluent sampling systems. The gaseous effluent sampling systems evaluated are located at the main plant ventilation stack (291-Z-1) and at a vessel vent stack (296-Z-3). A preliminary report, which was a paper study issued in April 1976, identified many deficiencies in the existing sampling systems and made recommendations for corrective action. The objectives of this experimental evaluation of those sampling systems were as follows: Characterize the radioactive aerosols in the stack effluents; Develop a tracer aerosol technique for validating particulate effluent sampling system performance; Evaluate the performance of the existing routine sampling systems and their compliance with the sponsor's criteria; and Recommend corrective action where required. The tracer aerosol approach to sampler evaluation was chosen because the low concentrations of radioactive particulates in the effluents would otherwise require much longer sampling times and thus more time to complete this evaluation. The following report describes the sampling systems that are the subject of this study and then details the experiments performed. The results are then presented and discussed. Much of the raw and finished data are included in the appendices

  10. Evaluation of Digital Classification of Polarimetric SAR Data for Iron-Mineralized Laterites Mapping in the Amazon Region

    Directory of Open Access Journals (Sweden)

    Cleber G. Oliveira

    2013-06-01

    Full Text Available This study evaluates the potential of C- and L-band polarimetric SAR data for the discrimination of iron-mineralized laterites in the Brazilian Amazon region. The study area is the N1 plateau located on the northern border of the Carajás Mineral Province, the most important Brazilian mineral province which has numerous mineral deposits, particularly the world’s largest iron deposits. The plateau is covered by low-density savanna-type vegetation (campus rupestres which contrasts visibly with the dense equatorial forest. The laterites are subdivided into three units: chemical crust, iron-ore duricrust, and hematite, of which only the latter two are of economic interest. Full polarimetric data from the airborne R99B sensor of the SIVAM/CENSIPAM (L-band system and the RADARSAT-2 satellite (C-band were evaluated. The study focused on an assessment of distinct schemes for digital classification based on decomposition theory and hybrid approach, which incorporates statistical analysis as input data derived from the target decomposition modeling. The results indicated that the polarimetric classifications presented a poor performance, with global Kappa values below 0.20. The accuracy for the identification of units of economic interest varied from 55% to 89%, albeit with high commission error values. In addition, the results using L-band were considered superior compared to C-band, which suggest that the roughness scale for laterite discrimination in the area is nearer to L than to C-band.

  11. ASTM STANDARD GUIDE FOR EVALUATING DISPOSAL OPTIONS FOR REUSE OF CONCRETE FROM NUCLEAR FACILITY DECOMMISSIONING

    International Nuclear Information System (INIS)

    Phillips, Ann Marie; Meservey, Richard H.

    2003-01-01

    Within the nuclear industry, many contaminated facilities that require decommissioning contain huge volumes of concrete. This concrete is generally disposed of as low-level waste at a high cost. Much of the concrete is lightly contaminated and could be reused as roadbed, fill material, or aggregate for new concrete, thus saving millions of dollars. However, because of the possibility of volumetric contamination and the lack of a method to evaluate the risks and costs of reusing concrete, reuse is rarely considered. To address this problem, Argonne National Laboratory-East (ANL-E) and the Idaho National Engineering and Environmental Laboratory teamed to write a ''concrete protocol'' to help evaluate the ramifications of reusing concrete within the U.S. Department of Energy (DOE). This document, titled the Protocol for Development of Authorized Release Limits for Concrete at U.S. Department of Energy Site (1) is based on ANL-E's previously developed scrap metal recycle protocols; on the 10-step method outlined in DOE's draft handbook, Controlling Release for Reuse or Recycle of Property Containing Residual Radioactive Material (2); and on DOE Order 4500.5, Radiation Protection of the Public and the Environment (3). The DOE concrete protocol was the basis for the ASTM Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning, which was written to make the information available to a wider audience outside DOE. The resulting ASTM Standard Guide is a more concise version that can be used by the nuclear industry worldwide to evaluate the risks and costs of reusing concrete from nuclear facility decommissioning. The bulk of the ASTM Standard Guide focuses on evaluating the dose and cost for each disposal option. The user calculates these from the detailed formulas and tabulated data provided, then compares the dose and cost for each disposal option to select the best option that meets regulatory requirements. With this information

  12. Evaluation of skyshine dose due to gamma-rays from a cobalt-60 irradiation facility

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okamoto, Shinichi; Ohnishi, Tokuhiro; Tsujii, Yukio

    1991-01-01

    We attempted to evaluate skyshine dose due to gamma-rays from a cobalt-60 irradiation facility. As the first step, the results of measurements and calculations were compared of the skyshine dose due to gamma-rays from the cobalt-60 source of 1.45 PBq set in the No.4 irradiation room of our laboratory. Distances of measuring points from the cobalt source were in the range from 17 m to about 100 m in the site of our office. Calculation was carried out with simplified single scattering method. The calculated values of the skyshine dose were higher than the measured values. For more precise evaluation of the skyshine dose, the following factors are to be considered; the dose rate distribution on the roof above the source and the attenuation of gamma-rays by air. (author)

  13. Evaluation of RayXpert® for shielding design of medical facilities

    Science.gov (United States)

    Derreumaux, Sylvie; Vecchiola, Sophie; Geoffray, Thomas; Etard, Cécile

    2017-09-01

    In a context of growing demands for expert evaluation concerning medical, industrial and research facilities, the French Institute for radiation protection and nuclear safety (IRSN) considered necessary to acquire new software for efficient dimensioning calculations. The selected software is RayXpert®. Before using this software in routine, exposure and transmission calculations for some basic configurations were validated. The validation was performed by the calculation of gamma dose constants and tenth value layers (TVL) for usual shielding materials and for radioisotopes most used in therapy (Ir-192, Co-60 and I-131). Calculated values were compared with results obtained using MCNPX as a reference code and with published values. The impact of different calculation parameters, such as the source emission rays considered for calculation and the use of biasing techniques, was evaluated.

  14. Lustre Distributed Name Space (DNE) Evaluation at the Oak Ridge Leadership Computing Facility (OLCF)

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, James S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Computational Sciences; Leverman, Dustin B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Computational Sciences; Hanley, Jesse A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Computational Sciences; Oral, Sarp [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Computational Sciences

    2016-08-22

    This document describes the Lustre Distributed Name Space (DNE) evaluation carried at the Oak Ridge Leadership Computing Facility (OLCF) between 2014 and 2015. DNE is a development project funded by the OpenSFS, to improve Lustre metadata performance and scalability. The development effort has been split into two parts, the first part (DNE P1) providing support for remote directories over remote Lustre Metadata Server (MDS) nodes and Metadata Target (MDT) devices, while the second phase (DNE P2) addressed split directories over multiple remote MDS nodes and MDT devices. The OLCF have been actively evaluating the performance, reliability, and the functionality of both DNE phases. For these tests, internal OLCF testbed were used. Results are promising and OLCF is planning on a full DNE deployment by mid-2016 timeframe on production systems.

  15. Morphologic evaluation and classification of facial asymmetry using 3-dimensional computed tomography.

    Science.gov (United States)

    Baek, Chaehwan; Paeng, Jun-Young; Lee, Janice S; Hong, Jongrak

    2012-05-01

    A systematic classification is needed for the diagnosis and surgical treatment of facial asymmetry. The purposes of this study were to analyze the skeletal structures of patients with facial asymmetry and to objectively classify these patients into groups according to these structural characteristics. Patients with facial asymmetry and recent computed tomographic images from 2005 through 2009 were included in this study, which was approved by the institutional review board. Linear measurements, angles, and reference planes on 3-dimensional computed tomograms were obtained, including maxillary (upper midline deviation, maxilla canting, and arch form discrepancy) and mandibular (menton deviation, gonion to midsagittal plane, ramus height, and frontal ramus inclination) measurements. All measurements were analyzed using paired t tests with Bonferroni correction followed by K-means cluster analysis using SPSS 13.0 to determine an objective classification of facial asymmetry in the enrolled patients. Kruskal-Wallis test was performed to verify differences among clustered groups. P < .05 was considered statistically significant. Forty-three patients (18 male, 25 female) were included in the study. They were classified into 4 groups based on cluster analysis. Their mean age was 24.3 ± 4.4 years. Group 1 included subjects (44% of patients) with asymmetry caused by a shift or lateralization of the mandibular body. Group 2 included subjects (39%) with a significant difference between the left and right ramus height with menton deviation to the short side. Group 3 included subjects (12%) with atypical asymmetry, including deviation of the menton to the short side, prominence of the angle/gonion on the larger side, and reverse maxillary canting. Group 4 included subjects (5%) with severe maxillary canting, ramus height differences, and menton deviation to the short side. In this study, patients with asymmetry were classified into 4 statistically distinct groups according to

  16. Dermal and inhalation acute toxic class methods: test procedures and biometric evaluations for the Globally Harmonized Classification System.

    Science.gov (United States)

    Holzhütter, H G; Genschow, E; Diener, W; Schlede, E

    2003-05-01

    The acute toxic class (ATC) methods were developed for determining LD(50)/LC(50) estimates of chemical substances with significantly fewer animals than needed when applying conventional LD(50)/LC(50) tests. The ATC methods are sequential stepwise procedures with fixed starting doses/concentrations and a maximum of six animals used per dose/concentration. The numbers of dead/moribund animals determine whether further testing is necessary or whether the test is terminated. In recent years we have developed classification procedures for the oral, dermal and inhalation routes of administration by using biometric methods. The biometric approach assumes a probit model for the mortality probability of a single animal and assigns the chemical to that toxicity class for which the best concordance is achieved between the statistically expected and the observed numbers of dead/moribund animals at the various steps of the test procedure. In previous publications we have demonstrated the validity of the biometric ATC methods on the basis of data obtained for the oral ATC method in two-animal ring studies with 15 participants from six countries. Although the test procedures and biometric evaluations for the dermal and inhalation ATC methods have already been published, there was a need for an adaptation of the classification schemes to the starting doses/concentrations of the Globally Harmonized Classification System (GHS) recently adopted by the Organization for Economic Co-operation and Development (OECD). Here we present the biometric evaluation of the dermal and inhalation ATC methods for the starting doses/concentrations of the GHS and of some other international classification systems still in use. We have developed new test procedures and decision rules for the dermal and inhalation ATC methods, which require significantly fewer animals to provide predictions of toxicity classes, that are equally good or even better than those achieved by using the conventional LD(50)/LC

  17. A Facile Approach to Evaluate Thermal Insulation Performance of Paper Cups

    Directory of Open Access Journals (Sweden)

    Yudi Kuang

    2015-01-01

    Full Text Available Paper cups are ubiquitous in daily life for serving water, soup, coffee, tea, and milk due to their convenience, biodegradability, recyclability, and sustainability. The thermal insulation performance of paper cups is of significance because they are used to supply hot food or drinks. Using an effective thermal conductivity to accurately evaluate the thermal insulation performance of paper cups is complex due to the inclusion of complicated components and a multilayer structure. Moreover, an effective thermal conductivity is unsuitable for evaluating thermal insulation performance of paper cups in the case of fluctuating temperature. In this work, we propose a facile approach to precisely analyze the thermal insulation performance of paper cups in a particular range of temperature by using an evaluation model based on the MISO (Multiple-Input Single-Output technical theory, which includes a characterization parameter (temperature factor and a measurement apparatus. A series of experiments was conducted according to this evaluation model, and the results show that this evaluation model enables accurate characterization of the thermal insulation performance of paper cups and provides an efficient theoretical basis for selecting paper materials for paper cups.

  18. Design Evaluation of a Piping System in the SELFA Sodium Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seok-Kwon; Jo, Young-Chul; Lee, Hyeong-Yeon; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this study, design evaluations on the SELFA piping system has been conducted according to the ASME B31.1 and RCC-MRx RD-3600. The conservatism of the two codes was quantified based on the evaluation results. It was shown that B31.1 was more conservative for the sustained loads while less conservative for thermal expansion loads when compare with those of RD-3600. However, all the evaluation results according to the two codes were within the code allowables. There are two main piping systems in the SELFA test loop. In this study, the integrity of the SELFA piping system has been evaluated according to the two design-by-rule (DBR) codes of ASME B31.1 and RCC-MRx RD-3600. B31.1 is an industry design code for power piping while RD-3600 is a class 3 nuclear DBR code. The conservatism of the two codes was quantified based on the evaluation results as per the two DBR codes. The sodium test facility of the SELFA is under construction at KAERI for the investigation of thermo-hydraulic behavior of finned-tube sodium-to-air heat exchanger.

  19. The evaluation of an analytical protocol for the determination of substances in waste for hazard classification.

    Science.gov (United States)

    Hennebert, Pierre; Papin, Arnaud; Padox, Jean-Marie; Hasebrouck, Benoît

    2013-07-01

    The classification of waste as hazardous could soon be assessed in Europe using largely the hazard properties of its constituents, according to the the Classification, Labelling and Packaging (CLP) regulation. Comprehensive knowledge of the component constituents of a given waste will therefore be necessary. An analytical protocol for determining waste composition is proposed, which includes using inductively coupled plasma (ICP) screening methods to identify major elements and gas chromatography/mass spectrometry (GC-MS) screening techniques to measure organic compounds. The method includes a gross or indicator measure of 'pools' of higher molecular weight organic substances that are taken to be less bioactive and less hazardous, and of unresolved 'mass' during the chromatography of volatile and semi-volatile compounds. The concentration of some elements and specific compounds that are linked to specific hazard properties and are subject to specific regulation (examples include: heavy metals, chromium(VI), cyanides, organo-halogens, and PCBs) are determined by classical quantitative analysis. To check the consistency of the analysis, the sum of the concentrations (including unresolved 'pools') should give a mass balance between 90% and 110%. Thirty-two laboratory samples comprising different industrial wastes (liquids and solids) were tested by two routine service laboratories, to give circa 7000 parameter results. Despite discrepancies in some parameters, a satisfactory sum of estimated or measured concentrations (analytical balance) of 90% was reached for 20 samples (63% of the overall total) during this first test exercise, with identified reasons for most of the unsatisfactory results. Regular use of this protocol (which is now included in the French legislation) has enabled service laboratories to reach a 90% mass balance for nearly all the solid samples tested, and most of liquid samples (difficulties were caused in some samples from polymers in solution and

  20. Seeing It All: Evaluating Supervised Machine Learning Methods for the Classification of Diverse Otariid Behaviours.

    Directory of Open Access Journals (Sweden)

    Monique A Ladds

    Full Text Available Constructing activity budgets for marine animals when they are at sea and cannot be directly observed is challenging, but recent advances in bio-logging technology offer solutions to this problem. Accelerometers can potentially identify a wide range of behaviours for animals based on unique patterns of acceleration. However, when analysing data derived from accelerometers, there are many statistical techniques available which when applied to different data sets produce different classification accuracies. We investigated a selection of supervised machine learning methods for interpreting behavioural data from captive otariids (fur seals and sea lions. We conducted controlled experiments with 12 seals, where their behaviours were filmed while they were wearing 3-axis accelerometers. From video we identified 26 behaviours that could be grouped into one of four categories (foraging, resting, travelling and grooming representing key behaviour states for wild seals. We used data from 10 seals to train four predictive classification models: stochastic gradient boosting (GBM, random forests, support vector machine using four different kernels and a baseline model: penalised logistic regression. We then took the best parameters from each model and cross-validated the results on the two seals unseen so far. We also investigated the influence of feature statistics (describing some characteristic of the seal, testing the models both with and without these. Cross-validation accuracies were lower than training accuracy, but the SVM with a polynomial kernel was still able to classify seal behaviour with high accuracy (>70%. Adding feature statistics improved accuracies across all models tested. Most categories of behaviour -resting, grooming and feeding-were all predicted with reasonable accuracy (52-81% by the SVM while travelling was poorly categorised (31-41%. These results show that model selection is important when classifying behaviour and that by using

  1. Determination of Importance Evaluation for Exploratory Studies Facility (ESF) Subsurface Testing Activities

    International Nuclear Information System (INIS)

    C.J. Byrne

    2001-01-01

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), and ancillary test and operation support areas including the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. This evaluation applies specifically to site characterization testing activities ongoing and planned in the Subsurface ESF. ESF site characterization activities are being performed to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. A more detailed description of these testing activities is provided in Section 6 of this DIE. Generally, the construction and operation of excavations associated with these testing activities are evaluated in the DIE for the Subsurface ESF (CRWMS M and O 1999a) and the DIE for the ESF ECRB Cross Drift (CRWMS M and O 2000a). The scope of this DIE also entails the proposed Unsaturated Zone (UZ) Transport Test at Busted Butte. Although, not a part of the TS Loop or ECRB Cross Drift, the associated testing activities are Subsurface testing activities. Busted Butte is located to the south south-east of the TS Loop and is outside the Conceptual Controlled Area Boundary (CCAB). These activities provide access to the Calico Hills (CH) geologic structure. In the case of Busted Butte, construction and operation of excavations are evaluated herein (since this activity was not previously evaluated in CRWMS M and O 1999a). The objectives of this DIE are to determine whether Subsurface ESF testing, and associated activities, could potentially impact site characterization testing and/or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified in Section 13. The validity and veracity of the

  2. Determination of Importance Evaluation for Exploratory Studies Facility (ESF) Subsurface Testing Activities

    Energy Technology Data Exchange (ETDEWEB)

    C.J. Byrne

    2001-02-20

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), and ancillary test and operation support areas including the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. This evaluation applies specifically to site characterization testing activities ongoing and planned in the Subsurface ESF. ESF site characterization activities are being performed to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. A more detailed description of these testing activities is provided in Section 6 of this DIE. Generally, the construction and operation of excavations associated with these testing activities are evaluated in the DIE for the Subsurface ESF (CRWMS M&O 1999a) and the DIE for the ESF ECRB Cross Drift (CRWMS M&O 2000a). The scope of this DIE also entails the proposed Unsaturated Zone (UZ) Transport Test at Busted Butte. Although, not a part of the TS Loop or ECRB Cross Drift, the associated testing activities are Subsurface testing activities. Busted Butte is located to the south south-east of the TS Loop and is outside the Conceptual Controlled Area Boundary (CCAB). These activities provide access to the Calico Hills (CH) geologic structure. In the case of Busted Butte, construction and operation of excavations are evaluated herein (since this activity was not previously evaluated in CRWMS M&O 1999a). The objectives of this DIE are to determine whether Subsurface ESF testing, and associated activities, could potentially impact site characterization testing and/or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified in Section 13. The validity and veracity of the individual

  3. Evaluation of engineered barrier materials for surface disposal facilities. Appendix 2: Brazil

    International Nuclear Information System (INIS)

    Endo, L.S.

    2001-01-01

    Full text: In practice, those nuclear installations that generate most wastes in Brazil often have interim storage facilities at the same site. They can also accommodate wastes from small users that have no suitable place to manage their wastes. The forecast at the time of the CRP for Brazilian waste generation due to all nuclear and radioactive activities by the year 2010 is to be about 5000 m 3 , not including the waste of 3500 m 3 from Goiania accident. With the impact of the accident on the public opinion, the quest for a safe disposal facility became more urgent, especially the siting and licensing a disposal facility which could receive the Goiania waste. Although the construction of a national repository was a matter of future decision at the time of the CRP, research programmes were being developed and carried out by the research institutes of the Brazilian National Commission of Nuclear Energy. The R and D programmes were primarily intended to establish required technical capability in dealing with the subject especially in terms of issues related to the evaluation of disposal facility performance and lifetime. Some activities of the programmes were within the scope of the CRP, namely: study of diffusion through cementitious materials; degradation of concrete due to chemical corrosion and microbiological attack; evaluation of additives for the improvement of structural concrete and cemented wasteform quality. In the work relating to the improvement of wasteforms and concrete, silica-fume was being evaluated as an admixture in the cementation process. Ion-exchange resins, a typical power reactor waste, and simulated liquid waste from fission production were used as reference wastes. The performance of the produced wasteforms was evaluated by measuring four properties of interest: setting time; heat developed during hydration process, compressive strength, and leachability. Results showed that the addition of silica-fume increased the compressive strength

  4. Determination of Importance Evaluation for Exploratory Studies Facility (ESF) Subsurface Testing Activities

    International Nuclear Information System (INIS)

    Goodin, S.

    2002-01-01

    This Determination of Importance Evaluation (DIE) applies to the Subsurface Exploratory Studies Facility (ESF), encompassing the Topopah Spring (TS) Loop from Station 0+00 meters (m) at the North Portal to breakthrough at the South Portal (approximately 78+77 m), and ancillary test and operation support areas including the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. This evaluation applies specifically to site characterization testing activities ongoing and planned in the Subsurface ESF. ESF site characterization activities are being performed to obtain the information necessary to determine whether the Yucca Mountain Site is suitable as a geologic repository for spent nuclear fuel and high-level radioactive waste. A more detailed description of these testing activities is provided in Section 6 of this DIE. Generally, the construction and operation of excavations associated with these testing activities are evaluated in the DIE for the Subsurface ESF (CRWMS M andO 1999a) and the DIE for the ESF ECRB Cross Drift (CRWMS M andO 2000a). The scope of this DIE also entails the proposed Unsaturated Zone (UZ) Transport Test at Busted Butte. Although, not a part of the TS Loop or ECRB Cross Drift, the associated testing activities are Subsurface testing activities. Busted Butte is located to the south south-east of the TS Loop and is outside the Conceptual Controlled Area Boundary (CCAB). These activities provide access to the Calico Hills (CH) geologic structure. In the case of Busted Butte, construction and operation of excavations are evaluated herein (since this activity was not previously evaluated in CRWMS M andO 1999a). The objectives of this DIE are to determine whether Subsurface ESF testing, and associated activities, could potentially impact site characterization testing and/or the waste isolation capabilities of the site. Controls needed to limit any potential impacts are identified in Section 13. The validity and veracity of the

  5. Process Evaluation of a Quality Improvement Project to Decrease Hospital Readmissions From Skilled Nursing Facilities.

    Science.gov (United States)

    Meehan, Thomas P; Qazi, Daniel J; Van Hoof, Thomas J; Ho, Shih-Yieh; Eckenrode, Sheila; Spenard, Ann; Pandolfi, Michelle; Johnson, Florence; Quetti, Deborah

    2015-08-01

    To describe and evaluate the impact of quality improvement (QI) support provided to skilled nursing facilities (SNFs) by a Quality Improvement Organization (QIO). Retrospective, mixed-method, process evaluation of a QI project intended to decrease preventable hospital readmissions from SNFs. Five SNFs in Connecticut. SNF Administrators, Directors of Nursing, Assistant Directors of Nursing, Admissions Coordinators, Registered Nurses, Certified Nursing Assistants, Receptionists, QIO Quality Improvement Consultant. QIO staff provided training and technical assistance to SNF administrative and clinical staff to establish or enhance QI infrastructure and implement an established set of QI tools [Interventions to Reduce Acute Care Transfers (INTERACT) tools]. Baseline SNF demographic, staffing, and hospital readmission data; baseline and follow-up SNF QI structure (QI Committee), processes (general and use of INTERACT tools), and outcome (30-day all-cause hospital readmission rates); details of QIO-provided training and technical assistance; QIO-perceived barriers to quality improvement; SNF leadership-perceived barriers, accomplishments, and suggestions for improvement of QIO support. Success occurred in establishing QI Committees and targeting preventable hospital readmissions, as well as implementing INTERACT tools in all SNFs; however, hospital readmission rates decreased in only 2 facilities. QIO staff and SNF leaders noted the ongoing challenge of engaging already busy SNF staff and leadership in QI activities. SNF leaders reported that they appreciated the training and technical assistance that their institutions received, although most noted that additional support was needed to bring about improvement in readmission rates. This process evaluation documented mixed clinical results but successfully identified opportunities to improve recruitment of and provision of technical support to participating SNFs. Recommendations are offered for others who wish to conduct

  6. Evaluating the effectiveness of training for nuclear facility personnel. Proceedings of the specialists' meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    One of the essential requirements for safe and reliable nuclear power plant operation and maintenance is the availability of competent personnel. The systematic approach to training (SAT) is recognized world-wide as the international best practice for attaining and maintaining the qualification and competence of nuclear power plant personnel. Many countries have applied and are now implementing or enhancing the use of SAT in their training systems, as demonstrated by the results of the IAEA World Survey on Nuclear Power Plant Personnel Training published in the beginning of 1999. Among the major challenges of human resource professionals is the need to measure the effectiveness of their training programs. Most training programs in the nuclear industry are effective because they are meeting legitimate needs and are conducted by competent, professional staff. Unfortunately, the extent of the impact of teaming is usually unknown or vague at best. Measurement and evaluation processes and procedures are usually inadequate or need further development and refinement. The IAEA has already been addressing the NPP personnel teaming problem during the last several years. Nevertheless, the scope of the problem is widening and new solutions are being developed. Therefore, the IAEA has decided to invite teaming professionals to a Specialists' Meeting to learn about and discuss NPP personnel training trends. The topic of this meeting, evaluating the effectiveness of training for nuclear facility personnel, was selected by the IAEA International Working Group on Training and Qualification of Nuclear Power Plant Personnel. A Specialists' Meeting on Evaluating the Effectiveness of Training for Nuclear Facility Personnel, organized in co-operation with EXITECH Corporation, the US DOE was attended by participants from 12 countries presenting 21 papers.

  7. Evaluating the effectiveness of training for nuclear facility personnel. Proceedings of the specialists' meeting

    International Nuclear Information System (INIS)

    2003-01-01

    One of the essential requirements for safe and reliable nuclear power plant operation and maintenance is the availability of competent personnel. The systematic approach to training (SAT) is recognized world-wide as the international best practice for attaining and maintaining the qualification and competence of nuclear power plant personnel. Many countries have applied and are now implementing or enhancing the use of SAT in their training systems, as demonstrated by the results of the IAEA World Survey on Nuclear Power Plant Personnel Training published in the beginning of 1999. Among the major challenges of human resource professionals is the need to measure the effectiveness of their training programs. Most training programs in the nuclear industry are effective because they are meeting legitimate needs and are conducted by competent, professional staff. Unfortunately, the extent of the impact of teaming is usually unknown or vague at best. Measurement and evaluation processes and procedures are usually inadequate or need further development and refinement. The IAEA has already been addressing the NPP personnel teaming problem during the last several years. Nevertheless, the scope of the problem is widening and new solutions are being developed. Therefore, the IAEA has decided to invite teaming professionals to a Specialists' Meeting to learn about and discuss NPP personnel training trends. The topic of this meeting, evaluating the effectiveness of training for nuclear facility personnel, was selected by the IAEA International Working Group on Training and Qualification of Nuclear Power Plant Personnel. A Specialists' Meeting on Evaluating the Effectiveness of Training for Nuclear Facility Personnel, organized in co-operation with EXITECH Corporation, the US DOE was attended by participants from 12 countries presenting 21 papers

  8. A comparison of metrics to evaluate the effects of hydro-facility passage stressors on fish

    Energy Technology Data Exchange (ETDEWEB)

    Colotelo, Alison H.; Goldman, Amy E.; Wagner, Katie A.; Brown, Richard S.; Deng, Z. Daniel; Richmond, Marshall C.

    2017-03-01

    Hydropower is the most common form of renewable energy, and countries worldwide are considering expanding hydropower to new areas. One of the challenges of hydropower deployment is mitigation of the environmental impacts including water quality, habitat alterations, and ecosystem connectivity. For fish species that inhabit river systems with hydropower facilities, passage through the facility to access spawning and rearing habitats can be particularly challenging. Fish moving downstream through a hydro-facility can be exposed to a number of stressors (e.g., rapid decompression, shear forces, blade strike and collision, and turbulence), which can all affect fish survival in direct and indirect ways. Many studies have investigated the effects of hydro-turbine passage on fish; however, the comparability among studies is limited by variation in the metrics and biological endpoints used. Future studies investigating the effects of hydro-turbine passage should focus on using metrics and endpoints that are easily comparable. This review summarizes four categories of metrics that are used in fisheries research and have application to hydro-turbine passage (i.e., mortality, injury, molecular metrics, behavior) and evaluates them based on several criteria (i.e., resources needed, invasiveness, comparability among stressors and species, and diagnostic properties). Additionally, these comparisons are put into context of study setting (i.e., laboratory vs. field). Overall, injury and molecular metrics are ideal for studies in which there is a need to understand the mechanisms of effect, whereas behavior and mortality metrics provide information on the whole body response of the fish. The study setting strongly influences the comparability among studies. In laboratory-based studies, stressors can be controlled by both type and magnitude, allowing for easy comparisons among studies. In contrast, field studies expose fish to realistic passage environments but the comparability is

  9. ESF [Exploratory Shaft Facility] impact evaluation report: Volume 2: Final report

    International Nuclear Information System (INIS)

    1985-08-01

    This report assesses the impacts of integrating an Exploratory Shaft Facility (ESF) with a high-level nuclear waste repository in salt. An evaluation to identify integration impacts is described for two specific ESF configurations (Cases 1 and 2) for each of the seven sites. These configurations are an ESF which uses two of the full size repository shafts, and an ESF with one 10-ft and one 22-ft diameter shaft. An evaluation of an ESF configuration (Case 3) with two 12-ft diameter shafts at three of the seven sites is also described. These sites are Deaf Smith, Davis Canyon, and Richton Dome. A fourth evaluation (Case 4) for the Deaf Smith site only, addresses a ''fast track'' subsurface development plan to allow waste emplacement by 1998. A fifth evaluation (Case 5), provides site-specific ES locations, for the three sites included in Case 3, which are supportive of a shaft siting study prepared by ONWI. The report presents development schedules depicting construction activities and time frames commencing with receipt of the repository Construction Authorization and proceeding to initiation of emplacement operations. These schedules are site specific and are presented for each of the five cases

  10. The evaluation of an analytical protocol for the determination of substances in waste for hazard classification

    Energy Technology Data Exchange (ETDEWEB)

    Hennebert, Pierre, E-mail: pierre.hennebert@ineris.fr [INERIS – Institut National de l’Environnement Industriel et des Risques, Domaine du Petit Arbois BP33, F-13545 Aix-en-Provence (France); Papin, Arnaud [INERIS, Parc Technologique ALATA, BP No. 2, 60550 Verneuil en Halatte (France); Padox, Jean-Marie [INERIS – Institut National de l’Environnement Industriel et des Risques, Domaine du Petit Arbois BP33, F-13545 Aix-en-Provence (France); Hasebrouck, Benoît [INERIS, Parc Technologique ALATA, BP No. 2, 60550 Verneuil en Halatte (France)

    2013-07-15

    Highlights: • Knowledge of wastes in substances will be necessary to assess HP1–HP15 hazard properties. • A new analytical protocol is proposed for this and tested by two service laboratories on 32 samples. • Sixty-three percentage of the samples have a satisfactory analytical balance between 90% and 110%. • Eighty-four percentage of the samples were classified identically (Seveso Directive) for their hazardousness by the two laboratories. • The method, in progress, is being normalized in France and is be proposed to CEN. - Abstract: The classification of waste as hazardous could soon be assessed in Europe using largely the hazard properties of its constituents, according to the the Classification, Labelling and Packaging (CLP) regulation. Comprehensive knowledge of the component constituents of a given waste will therefore be necessary. An analytical protocol for determining waste composition is proposed, which includes using inductively coupled plasma (ICP) screening methods to identify major elements and gas chromatography/mass spectrometry (GC–MS) screening techniques to measure organic compounds. The method includes a gross or indicator measure of ‘pools’ of higher molecular weight organic substances that are taken to be less bioactive and less hazardous, and of unresolved ‘mass’ during the chromatography of volatile and semi-volatile compounds. The concentration of some elements and specific compounds that are linked to specific hazard properties and are subject to specific regulation (examples include: heavy metals, chromium(VI), cyanides, organo-halogens, and PCBs) are determined by classical quantitative analysis. To check the consistency of the analysis, the sum of the concentrations (including unresolved ‘pools’) should give a mass balance between 90% and 110%. Thirty-two laboratory samples comprising different industrial wastes (liquids and solids) were tested by two routine service laboratories, to give circa 7000 parameter

  11. Preliminary safety evaluation of a commercial-scale krypton-85 encapsulation facility

    International Nuclear Information System (INIS)

    Christensen, A.B.; Tanner, J.E.; Knecht, D.A.

    1980-01-01

    This paper demonstrates that a commercial-scale facility for encapsulating krypton-85 in zeolite-5A or glass at a 2000 MTHM per year nuclear fuel reprocessing plant can be designed to contain fragments and the 340 to 850 kCi krypton-85 inventory from an assumed catastrophic failure of the high pressure vessel. The vessel failure was assumed as a worst case and was not based on a detailed design evaluation or operating experience. The process design is based on existing commercial hot isostatic pressing technology operated at up to 40 times the scale required for krypton encapsulation. From the calculated process gas inventory in the pressure vessel and vessel design, the maximum explosive energy of 8.4 kg TNT and resulting vessel plug and fragment velocities were calculated. The facility Containment Cell housing the high pressure vessel was designed to contain the gases, fragments, and the shock wave energy calculated for a hypothetical vessel failure. The Access Cell located directly above the Containment Cell was designed to be a tertiary confinement of krypton-85, should the access hatch be breached. 3 figures, 2 tables

  12. Evaluation of energy response of neutron rem monitor applied to high-energy accelerator facilities

    Energy Technology Data Exchange (ETDEWEB)

    Nakane, Yoshihiro; Harada, Yasunori; Sakamoto, Yukio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    2003-03-01

    A neutron rem monitor was newly developed for applying to the high-intensity proton accelerator facility (J-PARC) that is under construction as a joint project between the Japan Atomic Energy Research Institute and the High Energy Accelerator Research Organization. To measure the dose rate accurately for wide energy range of neutrons from thermal to high-energy region, the neutron rem monitor was fabricated by adding a lead breeder layer to a conventional neutron rem monitor. The energy response of the monitor was evaluated by using neutron transport calculations for the energy range from thermal to 150 MeV. For verifying the results, the response was measured at neutron fields for the energy range from thermal to 65 MeV. The comparisons between the energy response and dose conversion coefficients show that the newly developed neutron rem monitor has a good performance in energy response up to 150 MeV, suggesting that the present study offered prospects of a practical fabrication of the rem monitor applicable to the high intensity proton accelerator facility. (author)

  13. F/H Effluent Treatment Facility filtration upgrade alternative evaluations overview

    Energy Technology Data Exchange (ETDEWEB)

    Miles, W.C. Jr.; Poirier, M.R.; Brown, D.F.

    1992-01-01

    The F/H Effluent Treatment Facility (ETF) at the Savannah River Site (SRS) was designed to treat process wastewater from the 200-F/H Production Facilities (routine wastewater) as well as intermittent flows from the F/H Retention Basins and F/H Cooling Water Basins (nonroutine wastewater). Since start-up of the ETF at SRS in 1988, the treatment process has experienced difficulties processing routine and nonroutine wastewater. Studies have identified high bacteria and bacterial decomposition products in the wastewater as the cause for excessive fouling of the filtration system. In order to meet Waste Management requirements for the treatment of processed wastewater, an upgrade of the ETF filtration system is being developed. This upgrade must be able to process the nonroutine wastewater at design capacity. As a result, a study of alternative filter technologies was conducted utilizing simulated wastewater. The simulated wastewater tests have been completed. Three filter technologies, centrifugal polymeric ultrafilters, tubular polymeric ultrafilters, and backwashable cartridge filters have been selected for further evaluation utilizing actual ETF wastewater.

  14. F/H Effluent Treatment Facility filtration upgrade alternative evaluations overview

    Energy Technology Data Exchange (ETDEWEB)

    Miles, W.C. Jr.; Poirier, M.R.; Brown, D.F.

    1992-07-01

    The F/H Effluent Treatment Facility (ETF) at the Savannah River Site (SRS) was designed to treat process wastewater from the 200-F/H Production Facilities (routine wastewater) as well as intermittent flows from the F/H Retention Basins and F/H Cooling Water Basins (nonroutine wastewater). Since start-up of the ETF at SRS in 1988, the treatment process has experienced difficulties processing routine and nonroutine wastewater. Studies have identified high bacteria and bacterial decomposition products in the wastewater as the cause for excessive fouling of the filtration system. In order to meet Waste Management requirements for the treatment of processed wastewater, an upgrade of the ETF filtration system is being developed. This upgrade must be able to process the nonroutine wastewater at design capacity. As a result, a study of alternative filter technologies was conducted utilizing simulated wastewater. The simulated wastewater tests have been completed. Three filter technologies, centrifugal polymeric ultrafilters, tubular polymeric ultrafilters, and backwashable cartridge filters have been selected for further evaluation utilizing actual ETF wastewater.

  15. Nevada Nuclear Waste Storage Investigations: Exploratory Shaft Facility fluids and materials evaluation

    Energy Technology Data Exchange (ETDEWEB)

    West, K.A.

    1988-11-01

    The objective of this study was to determine if any fluids or materials used in the Exploratory Shaft Facility (ESF) of Yucca Mountain will make the mountain unsuitable for future construction of a nuclear waste repository. Yucca Mountain, an area on and adjacent to the Nevada Test Site in southern Nevada, USA, is a candidate site for permanent disposal of high-level radioactive waste from commercial nuclear power and defense nuclear activities. To properly characterize Yucca Mountain, it will be necessary to construct an underground test facility, in which in situ site characterization tests can be conducted. The candidate repository horizon at Yucca Mountain, however, could potentially be compromised by fluids and materials used in the site characterization tests. To minimize this possibility, Los Alamos National Laboratory was directed to evaluate the kinds of fluids and materials that will be used and their potential impacts on the site. A secondary objective was to identify fluids and materials, if any, that should be prohibited from, or controlled in, the underground. 56 refs., 19 figs., 11 tabs.

  16. Preliminary safety evaluation of a commercial-scale krypton-85 encapsulation facility

    International Nuclear Information System (INIS)

    Christensen, A.B.; Tanner, J.E.; Knecht, D.A.

    1980-09-01

    This report demonstrates that a commercial-scale facility for encapsulating krypton-85 in zeolite-5A or glass at a 2000 MTHM per year nuclear fuel reprocessing plant can be designed to contain fragments and the 340 to 850 kCi krypton-85 inventory from an assumed catastrophic failure of the high pressure vessel. The vessel failure was assumed as a worst case and was not based on a detailed design evaluation or operating experience. The process design is based on existing commercial hot isostatic pressing technology operated at up to 40 times the scale required for krypton encapsulation. From the calculated process gas inventory in the pressure vessel and vessel design, the explosive energy of 8.4 kg TNT and vessel plug and fragment velocities were calculated. The facility Containment Cell housing the high pressure vessel was designed to contain the gases, fragments, and the shock wave energy calculated for vessel failure. The Access Cell located directly above the Containment Cell was designed to be a tertiary confinement of krypton-85, should the access hatch be breached

  17. Nevada Nuclear Waste Storage Investigations: Exploratory Shaft Facility fluids and materials evaluation

    International Nuclear Information System (INIS)

    West, K.A.

    1988-11-01

    The objective of this study was to determine if any fluids or materials used in the Exploratory Shaft Facility (ESF) of Yucca Mountain will make the mountain unsuitable for future construction of a nuclear waste repository. Yucca Mountain, an area on and adjacent to the Nevada Test Site in southern Nevada, USA, is a candidate site for permanent disposal of high-level radioactive waste from commercial nuclear power and defense nuclear activities. To properly characterize Yucca Mountain, it will be necessary to construct an underground test facility, in which in situ site characterization tests can be conducted. The candidate repository horizon at Yucca Mountain, however, could potentially be compromised by fluids and materials used in the site characterization tests. To minimize this possibility, Los Alamos National Laboratory was directed to evaluate the kinds of fluids and materials that will be used and their potential impacts on the site. A secondary objective was to identify fluids and materials, if any, that should be prohibited from, or controlled in, the underground. 56 refs., 19 figs., 11 tabs

  18. Statistical evaluation of effluent monitoring data for the 200 Area Treated Effluent Disposal Facility

    International Nuclear Information System (INIS)

    Chou, C.J.; Johnson, V.G.

    2000-01-01

    The 200 Area Treated Effluent Disposal Facility (TEDF) consists of a pair of infiltration basins that receive wastewater originating from the 200 West and 200 East Areas of the Hanford Site. TEDF has been in operation since 1995 and is regulated by State Waste Discharge Permit ST 4502 (Ecology 1995) under the authority of Chapter 90.48 Revised Code of Washington (RCW) and Washington Administrative Code (WAC) Chapter 173-216. The permit stipulates monitoring requirements for effluent (or end-of-pipe) discharges and groundwater monitoring for TEDF. Groundwater monitoring began in 1992 prior to TEDF construction. Routine effluent monitoring in accordance with the permit requirements began in late April 1995 when the facility began operations. The State Waste Discharge Permit ST 4502 included a special permit condition (S.6). This condition specified a statistical study of the variability of permitted constituents in the effluent from TEDF during its first year of operation. The study was designed to (1) demonstrate compliance with the waste discharge permit; (2) determine the variability of all constituents in the effluent that have enforcement limits, early warning values, and monitoring requirements (WHC 1995); and (3) determine if concentrations of permitted constituents vary with season. Additional and more frequent sampling was conducted for the effluent variability study. Statistical evaluation results were provided in Chou and Johnson (1996). Parts of the original first year sampling and analysis plan (WHC 1995) were continued with routine monitoring required up to the present time

  19. F/H effluent treatment facility filtration upgrade alternative evaluations overview

    International Nuclear Information System (INIS)

    Miles, W.C. Jr.; Poirier, M.R.; Brown, D.F.

    1992-01-01

    The F/H Effluent Treatment Facility (ETF) at the Savannah River Site (SRS) was designed to treat process wastewater from the 200-F/H Production Facilities (routine wastewater) as well as intermittent flows from the F/H Retention Basins and F/H Cooling Water Basins (nonroutine wastewater). Since start-up of the ETF at SRS in 1988, the treatment process has experienced difficulties processing routine and nonroutine wastewater. Studies have identified high bacteria and bacterial decomposition products in the wastewater as the cause for excessive fouling of the filtration system. In order to meet Waste Management requirements for the treatment of processed wastewater, an upgrade of the ETF filtration system is being developed. This upgrade must be able to process the nonroutine wastewater at design capacity. As a result, a study of alternative filter technologies was conducted utilizing simulated wastewater. The simulated wastewater tests have been completed. Three filter technologies, centrifugal polymeric ultrafilters, tubular polymeric ultrafilters, and backwashable cartridge filters have been selected for further evaluation utilizing actual ETF wastewater. (author)

  20. Tracking implementation and (un)intended consequences: a process evaluation of an innovative peripheral health facility financing mechanism in Kenya.

    Science.gov (United States)

    Waweru, Evelyn; Goodman, Catherine; Kedenge, Sarah; Tsofa, Benjamin; Molyneux, Sassy

    2016-03-01

    In many African countries, user fees have failed to achieve intended access and quality of care improvements. Subsequent user fee reduction or elimination policies have often been poorly planned, without alternative sources of income for facilities. We describe early implementation of an innovative national health financing intervention in Kenya; the health sector services fund (HSSF). In HSSF, central funds are credited directly into a facility's bank account quarterly, and facility funds are managed by health facility management committees (HFMCs) including community representatives. HSSF is therefore a finance mechanism with potential to increase access to funds for peripheral facilities, support user fee reduction and improve equity in access. We conducted a process evaluation of HSSF implementation based on a theory of change underpinning the intervention. Methods included interviews at national, district and facility levels, facility record reviews, a structured exit survey and a document review. We found impressive achievements: HSSF funds were reaching facilities; funds were being overseen and used in a way that strengthened transparency and community involvement; and health workers' motivation and patient satisfaction improved. Challenges or unintended outcomes included: complex and centralized accounting requirements undermining efficiency; interactions between HSSF and user fees leading to difficulties in accessing crucial user fee funds; and some relationship problems between key players. Although user fees charged had not increased, national reduction policies were still not being adhered to. Finance mechanisms can have a strong positive impact on peripheral facilities, and HFMCs can play a valuable role in managing facilities. Although fiduciary oversight is essential, mechanisms should allow for local decision-making and ensure that unmanageable paperwork is avoided. There are also limits to what can be achieved with relatively small funds in

  1. Core Self-Evaluations as Personal Factors in the World Health Organization's International Classification of Functioning, Disability and Health Model: An Application in Persons with Spinal Cord Injury

    Science.gov (United States)

    Yaghmanian, Rana; Smedema, Susan Miller; Thompson, Kerry

    2017-01-01

    Purpose: To evaluate Chan, Gelman, Ditchman, Kim, and Chiu's (2009) revised World Health Organization's International Classification of Functioning, Disability and Health (ICF) model using core self-evaluations (CSE) to account for Personal Factors in persons with spinal cord injury (SCI). Method: One hundred eighty-seven adults with SCI were…

  2. Toxicity classification and evaluation of four pharmaceuticals classes: antibiotics, antineoplastics, cardiovascular, and sex hormones

    International Nuclear Information System (INIS)

    Sanderson, Hans; Brain, Richard A.; Johnson, David J.; Wilson, Christian J.; Solomon, Keith R.

    2004-01-01

    Four different classes of environmental concern are quantitatively and qualitatively assessed for environmental hazards; antibiotics (n = 226), antineoplastics (n = 81), cardiovascular (n = 272), and sex hormones (n 92). These along with an ECOSAR scan of all pharmaceuticals (n = 2848) were then classified according to the OECD aquatic toxicity classification system. The predicted species susceptibility is: daphnid > fish > algae, and the predicted rank order of relative toxicity: sex hormones > cardiovascular antibiotics > antineoplastics (Table 1). Generally, a relatively large proportion (1/3) of all pharmaceuticals are potentially very toxic to aquatic organisms (Table 2). The qualitative risk assessment ranking relative to probability and potential severity for human and environmental health effects is: antibiotics > sex hormones > cardiovascular > antineoplastics. (Q)SARs and pharmacodynamic information should be used to prioritize and steer experimental risk assessments of pharmaceuticals, and potentially, also be used in new drug discovery optimizing efficacy and in minimising environmental hazards of new products. Nuclear receptors are relatively well conserved in evolution. Currently, antibacterial resistance represents the most significant human health hazard, and potentially the largest non-target organism hazard is sex hormones acting as endocrine modulators in wildlife. Data for the individual compounds are accessible via http://www.uoguelph.ca/~hsander/

  3. Defense In-Depth Accident Analysis Evaluation of Tritium Facility Bldgs. 232-H, 233-H, and 234-H

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, A.

    1999-05-10

    'The primary purpose of this report is to document a Defense-in-Depth (DID) accident analysis evaluation for Department of Energy (DOE) Savannah River Site (SRS) Tritium Facility Buildings 232-H, 233-H, and 234-H. The purpose of a DID evaluation is to provide a more realistic view of facility radiological risks to the offsite public than the bounding deterministic analysis documented in the Safety Analysis Report, which credits only Safety Class items in the offsite dose evaluation.'

  4. Development and use of consolidated criteria for evaluation of emergency preparedness plans for DOE facilities

    International Nuclear Information System (INIS)

    Lerner, K.; Kier, P.H.; Baldwin, T.E.

    1995-01-01

    Emergency preparedness at US Department of Energy (DOE) facilities is promoted by development and quality control of response plans. To promote quality control efforts, DOE has developed a review document that consolidates requirements and guidance pertaining to emergency response planning from various DOE and regulatory sources. The Criteria for Evaluation of Operational Emergency Plans (herein referred to as the Criteria document) has been constructed and arranged to maximize ease of use in reviewing DOE response plans. Although developed as a review instrument, the document also serves as a de facto guide for plan development, and could potentially be useful outside the scope of its original intended DOE clientele. As regulatory and DOE requirements are revised and added in the future, the document will be updated to stay current

  5. Thermionic system evaluation test (TSET) facility construction: A United States and Russian effort

    International Nuclear Information System (INIS)

    Wold, S.K.

    1993-01-01

    The Thermionic System Evaluation Test (TSET) is a ground test of an unfueled Russian TOPAZ-II in-core thermionic space reactor powered by electric heaters. The facility that will be used for testing of the TOPAZ-II systems is located at the New Mexico Engineering Research Institute (NMERI) complex in Albuquerque, NM. The reassembly of the Russian test equipment is the responsibility of International Scientific Products (ISP), a San Jose, CA, company and Inertek, a Russian corporation, with support provided by engineers and technicians from Phillips Laboratory (PL), Sandia National Laboratories (SNL), Los Alamos National Laboratory (LANL), and the University of New Mexico (UNM). This test is the first test to be performed under the New Mexico Strategic Alliance agreement. This alliance consists of the PL, SNL, LANL, and UNM. The testing is being funded by the Strategic Defense Initiative Organization (SDIO) with the PL responsible for project execution

  6. Social-demographic profile and dose evaluation of the radiopharmaceutical facility workers

    International Nuclear Information System (INIS)

    Sanches, Matias P.; Carneiro, Janete C. Gaburo; Sordi, Gian Maria A.A.

    2009-01-01

    The main aims of this work are to identify the social-demographic profile of the workers based on stratification variables such as gender, age, and tasks performed by the workers, and to evaluate the annual collective doses of workers with potential risk of ionizing radiation exposure at the workplace during the years 2004 to 2008. In this context, the knowledge of the workforce composition in the facility responsible for the radioisotope production and its distribution was used. The individual monitoring programme has been carried out by individual dosimeters, TLDs, and internal contamination monitoring (in vivo method). The reported doses, in the period studied, suggest that the external exposure was the main source of occupational exposure in radioisotope production and distribution areas. The internal exposure was not included in the doses estimated, because it was negligible. This study has an important exploratory character, in order to analyze possible correlations related to adverse health effects, aiming to provide directions for occupational epidemiology research. (author)

  7. Social-demographic profile and dose evaluation of the radiopharmaceutical facility workers

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Matias P.; Carneiro, Janete C. Gaburo; Sordi, Gian Maria A.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: msanches@ipen.br

    2009-07-01

    The main aims of this work are to identify the social-demographic profile of the workers based on stratification variables such as gender, age, and tasks performed by the workers, and to evaluate the annual collective doses of workers with potential risk of ionizing radiation exposure at the workplace during the years 2004 to 2008. In this context, the knowledge of the workforce composition in the facility responsible for the radioisotope production and its distribution was used. The individual monitoring programme has been carried out by individual dosimeters, TLDs, and internal contamination monitoring (in vivo method). The reported doses, in the period studied, suggest that the external exposure was the main source of occupational exposure in radioisotope production and distribution areas. The internal exposure was not included in the doses estimated, because it was negligible. This study has an important exploratory character, in order to analyze possible correlations related to adverse health effects, aiming to provide directions for occupational epidemiology research. (author)

  8. [Implementation of cytology images classification--the Bethesda 2001 System--in a group of screened women from Podlaskie region--effect evaluation].

    Science.gov (United States)

    Zbroch, Tomasz; Knapp, Paweł Grzegorz; Knapp, Piotr Andrzej

    2007-09-01

    Increasing knowledge concerning carcinogenesis within cervical epithelium has forced us to make continues modifications of cytology classification of the cervical smears. Eventually, new descriptions of the submicroscopic cytomorphological abnormalities have enabled the implementation of Bethesda System which was meant to take place of the former Papanicolaou classification although temporarily both are sometimes used simultaneously. The aim of this study was to compare results of these two classification systems in the aspect of diagnostic accuracy verified by further tests of the diagnostic algorithm for the cervical lesion evaluation. The study was conducted in the group of women selected from general population, the criteria being the place of living and cervical cancer age risk group, in the consecutive periods of mass screening in Podlaski region. The performed diagnostic tests have been based on the commonly used algorithm, as well as identical laboratory and methodological conditions. Performed assessment revealed comparable diagnostic accuracy of both analyzing classifications, verified by histological examination, although with marked higher specificity for dysplastic lesions with decreased number of HSIL results and increased diagnosis of LSILs. Higher number of performed colposcopies and biopsies were an additional consequence of TBS classification. Results based on Bethesda System made it possible to find the sources and reasons of abnormalities with much greater precision, which enabled causing agent treatment. Two evaluated cytology classification systems, although not much different, depicted higher potential of TBS and better, more effective communication between cytology laboratory and gynecologist, making reasonable implementation of The Bethesda System in the daily cytology screening work.

  9. An evaluation of systematic tuberculosis screening at private facilities in Karachi, Pakistan.

    Directory of Open Access Journals (Sweden)

    Jacob Creswell

    Full Text Available BACKGROUND: In Pakistan, like many Asian countries, a large proportion of healthcare is provided through the private sector. We evaluated a systematic screening strategy to identify people with tuberculosis in private facilities in Karachi and assessed the approaches' ability to diagnose patients earlier in their disease progression. METHODS AND FINDINGS: Lay workers at 89 private clinics and a large hospital outpatient department screened all attendees for tuberculosis using a mobile phone-based questionnaire during one year. The number needed to screen to detect a case of tuberculosis was calculated. To evaluate early diagnosis, we tested for differences in cough duration and smear grading by screening facility. 529,447 people were screened, 1,010 smear-positive tuberculosis cases were detected and 942 (93.3% started treatment, representing 58.7% of all smear-positive cases notified in the intervention area. The number needed to screen to detect a smear-positive case was 124 (prevalence 806/100,000 at the hospital and 763 (prevalence 131/100,000 at the clinics; however, ten times the number of individuals were screened in clinics. People with smear-positive TB detected at the hospital were less likely to report cough lasting 2-3 weeks (RR 0.66 95%CI [0.49-0.90] and more likely to report cough duration >3 weeks (RR 1.10 95%CI [1.03-1.18]. Smear-positive cases at the clinics were less likely to have a +3 grade (RR 0.76 95%CI [0.63-0.92] and more likely to have +1 smear grade (RR 1.24 95%CI [1.02-1.51]. CONCLUSIONS: Tuberculosis screening at private facilities is acceptable and can yield large numbers of previously undiagnosed cases. Screening at general practitioner clinics may find cases earlier than at hospitals although more people must be screened to identify a case of tuberculosis. Limitations include lack of culture testing, therefore underestimating true TB prevalence. Using more sensitive and specific screening and diagnostic tests such

  10. An evaluation of systematic tuberculosis screening at private facilities in Karachi, Pakistan.

    Science.gov (United States)

    Creswell, Jacob; Khowaja, Saira; Codlin, Andrew; Hashmi, Rabia; Rasheed, Erum; Khan, Mubashir; Durab, Irfan; Mergenthaler, Christina; Hussain, Owais; Khan, Faisal; Khan, Aamir J

    2014-01-01

    In Pakistan, like many Asian countries, a large proportion of healthcare is provided through the private sector. We evaluated a systematic screening strategy to identify people with tuberculosis in private facilities in Karachi and assessed the approaches' ability to diagnose patients earlier in their disease progression. Lay workers at 89 private clinics and a large hospital outpatient department screened all attendees for tuberculosis using a mobile phone-based questionnaire during one year. The number needed to screen to detect a case of tuberculosis was calculated. To evaluate early diagnosis, we tested for differences in cough duration and smear grading by screening facility. 529,447 people were screened, 1,010 smear-positive tuberculosis cases were detected and 942 (93.3%) started treatment, representing 58.7% of all smear-positive cases notified in the intervention area. The number needed to screen to detect a smear-positive case was 124 (prevalence 806/100,000) at the hospital and 763 (prevalence 131/100,000) at the clinics; however, ten times the number of individuals were screened in clinics. People with smear-positive TB detected at the hospital were less likely to report cough lasting 2-3 weeks (RR 0.66 95%CI [0.49-0.90]) and more likely to report cough duration >3 weeks (RR 1.10 95%CI [1.03-1.18]). Smear-positive cases at the clinics were less likely to have a +3 grade (RR 0.76 95%CI [0.63-0.92]) and more likely to have +1 smear grade (RR 1.24 95%CI [1.02-1.51]). Tuberculosis screening at private facilities is acceptable and can yield large numbers of previously undiagnosed cases. Screening at general practitioner clinics may find cases earlier than at hospitals although more people must be screened to identify a case of tuberculosis. Limitations include lack of culture testing, therefore underestimating true TB prevalence. Using more sensitive and specific screening and diagnostic tests such as chest x-ray and Xpert MTB/RIF may improve results.

  11. Evaluation of case management of uncomplicated malaria in Haiti: a national health facility survey, 2012.

    Science.gov (United States)

    Landman, Keren Z; Jean, Samuel E; Existe, Alexandre; Akom, Eniko E; Chang, Michelle A; Lemoine, Jean Frantz; Mace, Kimberly E

    2015-10-09

    Malaria is a public health concern in Haiti, although there are limited data on its burden and case management. National malaria guidelines updated in 2012 recommend treatment with chloroquine and primaquine. In December 2012, a nationally-representative cross-sectional survey of health facilities (HFs) was conducted to determine malaria prevalence among febrile outpatients and malaria case management quality at baseline before scale-up of diagnostics and case management training. Among all 833 HFs nationwide, 30 were selected randomly, in proportion to total HFs per region, for 2-day evaluations. Survey teams inventoried HF material and human resources. Outpatients of all ages were screened for temperature >37.5 °C or history of fever; those without severe symptoms were consented and enrolled. Providers evaluated and treated enrolled patients according to HF standards; the survey teams documented provider-ordered diagnostic tests and treatment decisions. Facility-based test results [microscopy and malaria rapid diagnostic tests (RDTs)] were collected from HF laboratories. Blood smears for gold-standard microscopy, and dried blood spots for polymerase chain reaction (PCR) were obtained. Malaria diagnostic capacity, defined as completing a test for an enrolled patient or having adequate resources for RDTs or microscopy, was present in 11 (37 %) HFs. Among 459 outpatients screened, 257 (56 %) were febrile, of which 193 (75 %) were eligible, and 153 (80 %) were enrolled. Among 39 patients with facility-level malaria test results available on the survey day, 11 (28 %) were positive, of whom 6 (55 %) were treated with an anti-malarial. Twenty-seven (95 %) of the 28 patients testing negative were not treated with an anti-malarial. Of 114 patients without test results available, 35 (31 %) were presumptively treated for malaria. Altogether, 42 patients were treated with an anti-malarial, one (2 %) according to Haiti's 2012 guidelines. Of 140 gold-standard smears, none

  12. Water quality facility investigation report : final summary of project and evaluation of monitoring plan implementation.

    Science.gov (United States)

    2005-07-05

    The Oregon Department of Transportation (ODOT) has installed several stormwater : treatment facilities throughout the State to improve the quality of runoff discharged from : highways. These facilities include a variety of both above ground and below...

  13. Analysis format and evaluation methods for effluent particle sampling systems in nuclear facilities

    International Nuclear Information System (INIS)

    Schwendiman, L.C.; Glissmeyer, J.A.

    1976-06-01

    Airborne effluent sampling systems for nuclear facilities are frequently designed, installed, and operated without a systematic approach which discloses and takes into account all the circumstances and conditions which would affect the validity and adequacy of the sample. Without a comprehensive check list or something similar, the designer of the system may not be given the important information needed to provide a good design. In like manner, an already operating system may be better appraised. Furthermore, the discipline of a more formal approach may compel the one who will use the system to make sure he knows what he wants and can thus give the designer the needed information. An important consideration is the criteria to be applied to the samples to be taken. This analysis format consists of a listing of questions and statements calling forth the necessary information required to analyze a sampling system. With this information developed, one can proceed with an evaluation, the methodology of which is also discussed in the paper. Errors in probe placement, failure to sample at the proper rate, delivery line losses, and others are evaluated using mathematical models and empirically derived relationships. Experimental methods are also described for demonstrating that quality sampling will be achieved. The experiments include using a temporary, simple, but optimal sample collection system to evaluate the more complex systems. The use of tracer particles injected in the stream is also discussed. The samples obtained with the existing system are compared with those obtained by the temporary, optimal system

  14. Seismic design evaluation guidelines for buried piping for the DOE HLW Facilities

    International Nuclear Information System (INIS)

    Lin, Chi-Wen; Antaki, G.; Bandyopadhyay, K.; Bush, S.H.; Costantino, C.; Kennedy, R.

    1995-01-01

    This paper presents the seismic design and evaluation guidelines for underground piping for the Department of Energy (DOE) High-Level-Waste (HLW) Facilities. The underground piping includes both single and double containment steel pipes and concrete pipes with steel lining, with particular emphasis on the double containment piping. The design and evaluation guidelines presented in this paper follow the generally accepted beam-on-elastic-foundation analysis principle and the inertial response calculation method, respectively, for piping directly in contact with the soil or contained in a jacket. A standard analysis procedure is described along with the discussion of factors deemed to be significant for the design of the underground piping. The following key considerations are addressed: the design feature and safety requirements for the inner (core) pipe and the outer pipe; the effect of soil strain and wave passage; assimilation of the necessary seismic and soil data; inertial response calculation for the inner pipe; determination of support anchor movement loads; combination of design loads; and code comparison. Specifications and justifications of the key parameters used, stress components to be calculated and the allowable stress and strain limits for code evaluation are presented

  15. Evaluation of the 12-hour shift schedule at the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Lewis, P.M.; Swaim, D.J.; Rosa, R.R.; Colligan, M.J.; Booth, R.J.; Swint, M.J.

    1986-09-01

    The objective of this report are to evaluate the effect of the change to the 12-hour/day schedule on operational performance and safety of FFTF; to evaluate the degree to which the change to the 12-hour/day schedule has met its objectives; and to gather information that may be useful to FFTF management and the US Department of Energy (DOE) in evaluating 8- and 12-hour shift schedules at other facilities. The principal conclusion of this report is that the 12-hour/day shift schedule is a reasonable alternative to an 8-hour/day schedule at FFTF. As a result of the scedule change, it seems clear that plant performance improved in two ways. The operator error rate in keeping the Technical Specification Compliance Logs was already very low on the 8-hour shift. On the 12-hour shift, the rate was even lower. Also, the operator interface with craft personnel resulted in an increase in the productivity of the craft personnel

  16. A framework for evaluating automatic indexing or classification in the context of retrieval

    DEFF Research Database (Denmark)

    Golub, Korajlka; Soergel, Dagobert; Buchanan, George

    2016-01-01

    subject indexing, hard scientific evidence of their performance in operating information environments is scarce. A major reason for this is that research is usually conducted in laboratory conditions, excluding the complexities of real-life systems and situations. The paper reviews and discusses issues...... with existing evaluation approaches such as problems of aboutness and relevance assessments, implying the need to use more than a single “gold standard” method when evaluating indexing and retrieval and proposes a comprehensive evaluation framework. The framework is informed by a systematic review...

  17. Approaches used for clearance of land from nuclear facilities among several countries; evaluation for regulatory input

    International Nuclear Information System (INIS)

    Meck, Robert A.

    2012-01-01

    The purpose of this report is to describe, compare and evaluate the pros and cons of different methods for radiological characterisation of land areas after decommissioning of nuclear facilities. Specifically, it describes and examines the applied methods for the final status survey used in France, Germany, Spain, the United Kingdom (UK), and the United States (US).The Swedish Radiation Authority (Straalsaekerhetsmyndigheten, SSM) has authorised this comparison and evaluation for dissemination to industry and other interested parties. The information from the five countries in the study came from several kinds of sources. Professional network referrals identified subject matter experts in each of the five countries who were then contacted. The contacts provided electronic documents or online links to the publicly available information. The online links often led to additional world-wide-web searches and more information. In addition, some information was provided by private communication in e-mails. Other experts provided electronic proceedings of a conference or symposium. The information was compared and evaluated on for each country according to each of ten attributes: 1. Regulatory basis; 2. Scope; 3. Applicability; 4. Flexibility; 5. Transparency; 6. Roles and responsibilities of parties involved; 7. Quality program; 8. Detail of measurements descriptions; 9. Mathematical approaches; 10. Available assessment tools. A summary comparison across all countries for each attribute is presented in a table. Overall, it appears that each country has a goal of clearing lands from nuclear facilities at a risk of a fatality from residual radioactivity of on the order of one-in-a-million per year. However, their approaches vary in a number of aspects, and evaluation of these different approaches should take into account the regulatory culture of the respective country. High level considerations for developing regulations and guidance for implementation of final status

  18. Removal site evaluation report on the Tower Shielding Facility at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-09-01

    This removal site evaluation report for the Tower Shielding Facility (TSF) at Oak Ridge National Laboratory was prepared to provide the Environmental Restoration Program with information necessary to evaluate whether hazardous and/or radiological contaminants in and around the Tower Shielding Facility pose a substantial risk to human health or the environment (i.e., a high probability of adverse effects) and if remedial site evaluations or removal actions are, therefore, required. The scope of the project included a review of historical evidence regarding operations and use of the facility; interviews with facility personnel concerning current and past operating practices; a site inspection; and identification of hazard areas requiring maintenance, removal, or remedial actions. Based an the findings of this removal site evaluation, adequate efforts are currently being made at the TSF to contain and control existing contamination and hazardous substances on site in order to protect human health and the environment No conditions requiring maintenance or removal actions to mitigate imminent or potential threats to human health and the environment were identified during this evaluation. Given the current conditions and status of the buildings associated with the TSF, this removal site evaluation is considered complete and terminated according to the requirements for removal site evaluation termination

  19. Auditable safety analysis and final hazard classification for Buildings 1310-N and 1314-N

    International Nuclear Information System (INIS)

    Kloster, G.L.

    1997-05-01

    This document is a graded auditable safety analysis (ASA) of the deactivation activities planned for the 100-N facility segment comprised of the Building 1310-N pump silo (part of the Liquid Radioactive Waste Treatment Facility) and 1314-N Building (Liquid Waste Disposal Building).The ASA describes the hazards within the facility and evaluates the adequacy of the measures taken to reduce, control, or mitigate the identified hazards. This document also serves as the Final Hazard Classification (FHC) for the 1310-N pump silo and 1314-N Building segment. The FHC is radiological based on the Preliminary Hazard Classification and the total inventory of radioactive and hazardous materials in the segment

  20. Development of a methodology for safety classification on a non-reactor nuclear facility illustrated using an specific example; Entwicklung einer Methodik zur Sicherheitsklassifizierung fuer eine kerntechnische Anlage ohne Reaktor an einem spezifischen Beispiel

    Energy Technology Data Exchange (ETDEWEB)

    Scheuermann, F.; Lehradt, O.; Traichel, A. [NUKEM Technologies Engineering Services GmbH, Alzenau (Germany)

    2015-07-01

    To realize the safety of personnel and environment systems and components of nuclear facilities are classified according to their potential danger into safety classes. Based on this classification different demands on the manufacturing quality result. The objective of this work is to present the standardized method developed by NUKEM Technologies Engineering Services for the categorization into the safety classes restricted to Non-reactor nuclear facilities (NRNF). Exemplary the methodology is used on the complex Russian normative system (four safety classes). For NRNF only the lower two safety classes are relevant. The classification into the lowest safety class 4 is accordingly if the maximum resulting dose following from clean-up actions in case of incidents/accidents remains below 20 mSv and the volume activity restrictions of set in NRB-99/2009 are met. The methodology is illustrated using an example. In short the methodology consists of: - Determination of the working time to remove consequences of incidents, - Calculation of the dose resulting from direct radiation and due to inhalation during these works. The application of this methodology avoids over-conservative approaches. As a result some previously higher classified equipment can be classified into the lower safety class.

  1. Computed tomographic evaluation of the proximal femur: A predictive classification in displaced femoral neck fracture management

    Directory of Open Access Journals (Sweden)

    Narender Kumar Magu

    2014-01-01

    classification based on the femoral head size (type I and type II is proposed. Osteosynthesis should be the preferred method of treatment in type I and osteotomy or prosthetic replacement is the method of choice for type II femoral neck fractures.

  2. Evaluation of environmental-control technologies for commercial nuclear fuel-conversion (UF6) facilities

    International Nuclear Information System (INIS)

    Perkins, B.L.

    1982-10-01

    At present in the United States, there are two commercial conversion facilities. These facilities process uranium concentrate into UF 6 for shipment to the enrichment facilities. One conversion facility uses a dry hydrofluor process, whereas the other facility uses a process known as the wet solvent extraction-fluorination process. Because of the different processes used in the two plants, waste characteristics, quantities, and treatment practices differ at each facility. Wastes and effluent streams contain impurities found in the concentrate (such as uranium daughters, vanadium, molybdenum, selenium, arsenic, and ammonia) and process chemicals used in the circuit (including fluorine, nitrogen, and hydrogen), as well as small quantities of uranium. Studies of suitable disposal options for the solid wastes and sludges generated at the facilities and the long-term effects of emissions to the ambient environment are needed. 30 figures, 34 tables

  3. A personal computer code for seismic evaluations of nuclear power plant facilities

    International Nuclear Information System (INIS)

    Xu, J.; Graves, H.

    1991-01-01

    In the process of review and evaluation of licensing issues related to nuclear power plants, it is essential to understand the behavior of seismic loading, foundation and structural properties and their impact on the overall structural response. In most cases, such knowledge could be obtained by using simplified engineering models which, when properly implemented, can capture the essential parameters describing the physics of the problem. Such models do not require execution on large computer systems and could be implemented through a personal computer (PC) based capability. Recognizing the need for a PC software package that can perform structural response computations required for typical licensing reviews, the US Nuclear Regulatory Commission sponsored the development of a PC operated computer software package CARES (Computer Analysis for Rapid Evaluation of Structures) system. This development was undertaken by Brookhaven National Laboratory (BNL) during FY's 1988 and 1989. A wide range of computer programs and modeling approaches are often used to justify the safety of nuclear power plants. It is often difficult to assess the validity and accuracy of the results submitted by various utilities without developing comparable computer solutions. Taken this into consideration, CARES is designed as an integrated computational system which can perform rapid evaluations of structural behavior and examine capability of nuclear power plant facilities, thus CARES may be used by the NRC to determine the validity and accuracy of analysis methodologies employed for structural safety evaluations of nuclear power plants. CARES has been designed to operate on a PC, have user friendly input/output interface, and have quick turnaround. This paper describes the various features which have been implemented into the seismic module of CARES version 1.0

  4. Establishment on the classification scheme for the Evaluation System of the Decommissioning Information and Data

    International Nuclear Information System (INIS)

    Park, S. K.; Ji, Y. H.; Chung, U. S.

    2010-01-01

    According to the requirement, the items for the evaluation system were distinguished with the understanding of the code and it's value, the relation of the technology and it's problems, the relation with the systematical structure of the DECOMMIS-I and its' advantages and disadvantages. The detailed data model (the connection with entities) was structured as of the Information and data on the evaluation items. The ERD(Entity Relationship Diagram) on the characterization was set up. The conceptual modeling (the prototyping) which be on the base of these all result was established

  5. A personal computer code for seismic evaluations of nuclear power plant facilities

    International Nuclear Information System (INIS)

    Xu, J.; Graves, H.

    1990-01-01

    A wide range of computer programs and modeling approaches are often used to justify the safety of nuclear power plants. It is often difficult to assess the validity and accuracy of the results submitted by various utilities without developing comparable computer solutions. Taken this into consideration, CARES is designed as an integrated computational system which can perform rapid evaluations of structural behavior and examine capability of nuclear power plant facilities, thus CARES may be used by the NRC to determine the validity and accuracy of analysis methodologies employed for structural safety evaluations of nuclear power plants. CARES has been designed to: operate on a PC, have user friendly input/output interface, and have quick turnaround. The CARES program is structured in a modular format. Each module performs a specific type of analysis. The basic modules of the system are associated with capabilities for static, seismic and nonlinear analyses. This paper describes the various features which have been implemented into the Seismic Module of CARES version 1.0. In Section 2 a description of the Seismic Module is provided. The methodologies and computational procedures thus far implemented into the Seismic Module are described in Section 3. Finally, a complete demonstration of the computational capability of CARES in a typical soil-structure interaction analysis is given in Section 4 and conclusions are presented in Section 5. 5 refs., 4 figs

  6. Facile synthesis of indole-pyrimidine hybrids and evaluation of their anticancer and antimicrobial activity

    Directory of Open Access Journals (Sweden)

    Nikhila Gokhale

    2017-11-01

    Full Text Available The paper describes the facile synthesis of new N-cyclopropyl-1-methyl-1H-indole-2-carboxamide derivatives bearing substituted 2-amino pyrimidine moiety at position-3 of the indole ring. All the intermediate and title compounds were characterized adeptly by 1H NMR, 13C NMR, ESI–MS and elemental analyses. These compounds were evaluated for their in vitro anticancer activity against HeLa, HepG2 and MCF-7 cells. Three among 22 molecules, showed more than 70% growth inhibition against all three tested cancer cells. The nature of the substituent group on the pyrimidine ring (R2 affected significantly the anti-proliferative activity of the molecules. The anti-microbial evaluation of the title molecules revealed the significance of fluoro/chloro groups (R2 in enhancing their inhibition activity. Eight molecules which contain fluoro/chloro groups showed potent anti-microbial activity. In addition, the active molecules displayed negligible toxicity to benign Vero cells.

  7. Performance Evaluation of the International Space Station Flow Boiling and Condensation Experiment (FBCE) Test Facility

    Science.gov (United States)

    Hasan, Mohammad; Balasubramaniam, R.; Nahra, Henry; Mackey, Jeff; Hall, Nancy; Frankenfield, Bruce; Harpster, George; May, Rochelle; Mudawar, Issam; Kharangate, Chirag R.; hide

    2016-01-01

    A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.

  8. Shield wall evaluation of hot cell facility for advanced spent fuel conditioning process

    International Nuclear Information System (INIS)

    Cho, I. J.; Kuk, D. H.; Ko, J. H.; Jung, W. M.; Yoo, G. S.; Lee, E. P.; Park, S. W.

    2002-01-01

    The future hot cell is located in the Irradiated Material Experiment Facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI). It is β-γ type hot cell that was constructed on the base floor in IMEF building for irradiated material testing. And this hot cell will be used for carrying out the Advanced spent fuel Conditioning Process (ACP). The radiation shielding capability of hot cell should be sufficient to meet the radiation dose requirements in the related regulations. Because the radioactive sources of ACP are expected to be higher than radioactive sources of IMEF design criteria, the future hot cell in current status is unsatisfactory to hot test of ACP. So the shielding analysis of the future hot cell is performed to evaluate shielding ability of concrete shield wall. The shielding analysis included (a) identification of ACP source term; (b) photon source spectrum; (c) shielding analysis by QADS and MCNP-4C; and (d) enhancement of concrete shield wall. In this research, dose rates are obtained according to ACP source, geometry and hot cell shield wall thickness. And the evaluation and reinforcement thickness of the shield wall about future hot cell are concluded

  9. Emergency and backup power supplies at Department of Energy facilities: Augmented Evaluation Team -- Final report

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This report documents the results of the Defense Programs (DP) Augmented Evaluation Team (AET) review of emergency and backup power supplies (i.e., generator, uninterruptible power supply, and battery systems) at DP facilities. The review was conducted in response to concerns expressed by former Secretary of Energy James D. Watkins over the number of incidents where backup power sources failed to provide electrical power during tests or actual demands. The AET conducted a series of on-site reviews for the purpose of understanding the design, operation, maintenance, and safety significance of emergency and backup power (E&BP) supplies. The AET found that the quality of programs related to maintenance of backup power systems varies greatly among the sites visited, and often among facilities at the same site. No major safety issues were identified. However, there are areas where the AET believes the reliability of emergency and backup power systems can and should be improved. Recommendations for improving the performance of E&BP systems are provided in this report. The report also discusses progress made by Management and Operating (M&O) contractors to improve the reliability of backup sources used in safety significant applications. One area that requires further attention is the analysis and understanding of the safety implications of backup power equipment. This understanding is needed for proper graded-approach implementation of Department of Energy (DOE) Orders, and to help ensure that equipment important to the safety of DOE workers, the public, and the environment is identified, classified, recognized, and treated as such by designers, users, and maintainers. Another area considered important for improving E&BP system performance is the assignment of overall ownership responsibility and authority for ensuring that E&BP equipment performs adequately and that reliability and availability are maintained at acceptable levels.

  10. Evaluation of the initial and final radiological status of a nuclear facility in sanitation status

    International Nuclear Information System (INIS)

    Granier, Guy; Aubonnet, Emilie; Courbet, Christele; Desnoyers, Yvon; Dubot, Didier; Fichet, Pascal; Nokhamzon, Jean-Guy; Ollivier Dehaye, Catherine; Pillette-Cousin, Lucien; Mahe, Charly

    2017-02-01

    This technical report is a guideline for radiological assessment of a nuclear facility in remediation stages. From initial state of remediation to final status survey it describes the best suited statistical or geostatistical approach for the characterization of sites contaminated by radionuclides. Prior to any characterization campaign an historical analysis coupled with a function analysis targeted investigations is fundamental to obtain a robust overview. The evaluation of the amount of radioactive material present in a defined area requires a sampling strategy correlated with characterization objective. On the other hand correlation between remediation objectives and characterization objectives also requires knowing acceptable level of risk. This give better inputs to allow available resources and take into account environmental constraints. In particular, radiological characterization of infrastructures is one of the key step to conduct industrial project of decommissioning nuclear facilities in remediation. It needs a reliable initial diagnosis to obtain an efficient waste management with a financial control Optimization of the production of nuclear waste. It is an important part of Setting the Off Final - Dismantling). This approach is compatible with French Regulation (Guide 14 ASN) for the first and second line of defence. Annexes provide feedback of experimentation of this methodology. This report supplements the methodological guide published by the GT10 CETAMA entitled 'Soil Radiological Characterisation Methodology' (CEA-R 6386). The latter is intended for project managers and covers all issues related to the characterization projects for soil. This guideline concern specifically design engineers in charge of implementation program at the different stages of investigation and data processing. Similarly, the proposed methodology can be broken for the characterization of chemical pollution and process equipment. (authors)

  11. Further Classification and Methodological Considerations of Evaluations for Online Discussion in Instructional Settings

    Science.gov (United States)

    Spatariu, Alexandru; Winsor, Denise L.; Simpson, Cynthia; Hosman, Eric

    2016-01-01

    With the rapid advancements of technology, online communication in both K-12 and post-secondary instruction has been widely implemented. Instructors as well as researchers have used various frameworks to evaluate different aspects of online discussions' quality. The online discussions take place synchronously or asynchronously in chat rooms,…

  12. Healthcare Text Classification System and its Performance Evaluation: A Source of Better Intelligence by Characterizing Healthcare Text.

    Science.gov (United States)

    Srivastava, Saurabh Kumar; Singh, Sandeep Kumar; Suri, Jasjit S

    2018-04-13

    A machine learning (ML)-based text classification system has several classifiers. The performance evaluation (PE) of the ML system is typically driven by the training data size and the partition protocols used. Such systems lead to low accuracy because the text classification systems lack the ability to model the input text data in terms of noise characteristics. This research study proposes a concept of misrepresentation ratio (MRR) on input healthcare text data and models the PE criteria for validating the hypothesis. Further, such a novel system provides a platform to amalgamate several attributes of the ML system such as: data size, classifier type, partitioning protocol and percentage MRR. Our comprehensive data analysis consisted of five types of text data sets (TwitterA, WebKB4, Disease, Reuters (R8), and SMS); five kinds of classifiers (support vector machine with linear kernel (SVM-L), MLP-based neural network, AdaBoost, stochastic gradient descent and decision tree); and five types of training protocols (K2, K4, K5, K10 and JK). Using the decreasing order of MRR, our ML system demonstrates the mean classification accuracies as: 70.13 ± 0.15%, 87.34 ± 0.06%, 93.73 ± 0.03%, 94.45 ± 0.03% and 97.83 ± 0.01%, respectively, using all the classifiers and protocols. The corresponding AUC is 0.98 for SMS data using Multi-Layer Perceptron (MLP) based neural network. All the classifiers, the best accuracy of 91.84 ± 0.04% is shown to be of MLP-based neural network and this is 6% better over previously published. Further we observed that as MRR decreases, the system robustness increases and validated by standard deviations. The overall text system accuracy using all data types, classifiers, protocols is 89%, thereby showing the entire ML system to be novel, robust and unique. The system is also tested for stability and reliability.

  13. New FIGO and Swedish intrapartum cardiotocography classification systems incorporated in the fetal ECG ST analysis (STAN) interpretation algorithm: agreements and discrepancies in cardiotocography classification and evaluation of significant ST events.

    Science.gov (United States)

    Olofsson, Per; Norén, Håkan; Carlsson, Ann

    2018-02-01

    The updated intrapartum cardiotocography (CTG) classification system by FIGO in 2015 (FIGO2015) and the FIGO2015-approached classification by the Swedish Society of Obstetricians and Gynecologist in 2017 (SSOG2017) are not harmonized with the fetal ECG ST analysis (STAN) algorithm from 2007 (STAN2007). The study aimed to reveal homogeneity and agreement between the systems in classifying CTG and ST events, and relate them to maternal and perinatal outcomes. Among CTG traces with ST events, 100 traces originally classified as normal, 100 as suspicious and 100 as pathological were randomly selected from a STAN database and classified by two experts in consensus. Homogeneity and agreement statistics between the CTG classifications were performed. Maternal and perinatal outcomes were evaluated in cases with clinically hidden ST data (n = 151). A two-tailed p ST events, heterogeneities were significant and agreements moderate to almost perfect (STAN2007 vs. FIGO2015 0.86, 0.72; STAN2007 vs. SSOG2017 0.92, 0.84; FIGO2015 vs. SSOG2017 0.94, 0.87). Significant ST events occurred more often combined with STAN2007 than with FIGO2015 classification, but not with SSOG2017; correct identification of adverse outcomes was not significantly different between the systems. There are discrepancies in the classification of CTG patterns and significant ST events between the old and new systems. The clinical relevance of the findings remains to be shown. © 2017 The Authors. Acta Obstetricia et Gynecologica Scandinavica published by John Wiley & Sons Ltd on behalf of Nordic Federation of Societies of Obstetrics and Gynecology (NFOG).

  14. Classification of Flotation Frothers

    Directory of Open Access Journals (Sweden)

    Jan Drzymala

    2018-02-01

    Full Text Available In this paper, a scheme of flotation frothers classification is presented. The scheme first indicates the physical system in which a frother is present and four of them i.e., pure state, aqueous solution, aqueous solution/gas system and aqueous solution/gas/solid system are distinguished. As a result, there are numerous classifications of flotation frothers. The classifications can be organized into a scheme described in detail in this paper. The frother can be present in one of four physical systems, that is pure state, aqueous solution, aqueous solution/gas and aqueous solution/gas/solid system. It results from the paper that a meaningful classification of frothers relies on choosing the physical system and next feature, trend, parameter or parameters according to which the classification is performed. The proposed classification can play a useful role in characterizing and evaluation of flotation frothers.

  15. An evaluation on the scenarios of work trajectory during installation of dismantling equipment for decommissioning of nuclear facilities

    International Nuclear Information System (INIS)

    Jeong, KwanSeong; Choi, ByungSeon; Moon, JeiKwon; Hyun, Dongjun; Lee, Jonghwan; Kim, IkJune; Kim, GeunHo; Kang, ShinYoung; Choi, JongWon; Jeong, SeongYoung; Ahn, SangMyeon; Lee, JungJun

    2016-01-01

    Highlights: • An evaluation on the scenarios of work trajectory. • An evaluation using the virtual decommissioning environments. • An evaluation on work movement under radiation environments. - Abstract: This study is intended to suggest an ergonomic evaluation on the working postural comfort. This study issued for the first time a methodology in view of combination between visual field and comfort. Especially, the ergonomic evaluation using the virtual decommissioning environments is user-friendly because setup of physical mock-up environments is difficult. This study verified the front and standing postures are best working postures during movement under radiation environments of nuclear facilities. It is expected that this methodology will make it possible to establish the ergonomic plan for decommissioning of nuclear facilities and safety of decommissioning will be improved and also decommissioning costs also can be reduced.

  16. Evaluation of performance indicators applied to a material recovery facility fed by mixed packaging waste.

    Science.gov (United States)

    Mastellone, Maria Laura; Cremiato, Raffaele; Zaccariello, Lucio; Lotito, Roberta

    2017-06-01

    Most of the integrated systems for municipal solid waste management aim to increase the recycling of secondary materials by means of physical processes including sorting, shredding and reprocessing. Several restrictions prevent from reaching a very high material recycling efficiency: the variability of the composition of new-marketed materials used for packaging production and its shape and complexity are critical issues. The packaging goods are in fact made of different materials (aluminium, polymers, paper, etc.), possibly assembled, having different shape (flat, cylindrical, one-dimensional, etc.), density, colours, optical properties and so on. These aspects limit the effectiveness and efficiency of the sorting and reprocessing plants. The scope of this study was to evaluate the performance of a large scale Material Recovery Facility (MRF) by utilizing data collected during a long period of monitoring. The database resulted from the measured data has been organized in four sections: (1) data related to the amount and type of inlet waste; (2) amount and composition of output products and waste; (3) operating data (such as worked hours for shift, planned and unscheduled maintenance time, setting parameters of the equipment, and energy consumption for shift); (4) economic data (value of each product, disposal price for the produced waste, penalty for non-compliance of products and waste, etc.). A part of this database has been utilized to build an executive dashboard composed by a set of performance indicators suitable to measure the effectiveness and the efficiency of the MRF operations. The dashboard revealed itself as a powerful tool to support managers and engineers in their decisions in respect to the market demand or compliance regulation variation as well as in the designing of the lay-out improvements. The results indicated that the 40% of the input waste was recovered as valuable products and that a large part of these (88%) complied with the standards of

  17. An empirical evaluation of classification algorithms for fault prediction in open source projects

    Directory of Open Access Journals (Sweden)

    Arvinder Kaur

    2018-01-01

    Full Text Available Creating software with high quality has become difficult these days with the fact that size and complexity of the developed software is high. Predicting the quality of software in early phases helps to reduce testing resources. Various statistical and machine learning techniques are used for prediction of the quality of the software. In this paper, six machine learning models have been used for software quality prediction on five open source software. Varieties of metrics have been evaluated for the software including C & K, Henderson & Sellers, McCabe etc. Results show that Random Forest and Bagging produce good results while Naïve Bayes is least preferable for prediction.

  18. A Systematic Evaluation of Feature Selection and Classification Algorithms Using Simulated and Real miRNA Sequencing Data

    Directory of Open Access Journals (Sweden)

    Sheng Yang

    2015-01-01

    Full Text Available Sequencing is widely used to discover associations between microRNAs (miRNAs and diseases. However, the negative binomial distribution (NB and high dimensionality of data obtained using sequencing can lead to low-power results and low reproducibility. Several statistical learning algorithms have been proposed to address sequencing data, and although evaluation of these methods is essential, such studies are relatively rare. The performance of seven feature selection (FS algorithms, including baySeq, DESeq, edgeR, the rank sum test, lasso, particle swarm optimistic decision tree, and random forest (RF, was compared by simulation under different conditions based on the difference of the mean, the dispersion parameter of the NB, and the signal to noise ratio. Real data were used to evaluate the performance of RF, logistic regression, and support vector machine. Based on the simulation and real data, we discuss the behaviour of the FS and classification algorithms. The Apriori algorithm identified frequent item sets (mir-133a, mir-133b, mir-183, mir-937, and mir-96 from among the deregulated miRNAs of six datasets from The Cancer Genomics Atlas. Taking these findings altogether and considering computational memory requirements, we propose a strategy that combines edgeR and DESeq for large sample sizes.

  19. A risk-based classification scheme for genetically modified foods. III: Evaluation using a panel of reference foods.

    Science.gov (United States)

    Chao, Eunice; Krewski, Daniel

    2008-12-01

    This paper presents an exploratory evaluation of four functional components of a proposed risk-based classification scheme (RBCS) for crop-derived genetically modified (GM) foods in a concordance study. Two independent raters assigned concern levels to 20 reference GM foods using a rating form based on the proposed RBCS. The four components of evaluation were: (1) degree of concordance, (2) distribution across concern levels, (3) discriminating ability of the scheme, and (4) ease of use. At least one of the 20 reference foods was assigned to each of the possible concern levels, demonstrating the ability of the scheme to identify GM foods of different concern with respect to potential health risk. There was reasonably good concordance between the two raters for the three separate parts of the RBCS. The raters agreed that the criteria in the scheme were sufficiently clear in discriminating reference foods into different concern levels, and that with some experience, the scheme was reasonably easy to use. Specific issues and suggestions for improvements identified in the concordance study are discussed.

  20. A Decision Tool to Evaluate Budgeting Methodologies for Estimating Facility Recapitalization Requirements

    National Research Council Canada - National Science Library

    Hickman, Krista M

    2008-01-01

    .... Specifically, the thesis sought to answer an overarching research question addressing the importance of recapitalization and the best method to estimate the facility recapitalization budget using...

  1. Structural evaluation of spent nuclear fuel storage facilities under aircraft crash impact. Numerical study on evaluation of sealing performance of metal cask subjected to impact force

    International Nuclear Information System (INIS)

    Namba, Kosuke; Shirai, Koji; Saegusa, Toshiari

    2008-01-01

    A lot of safety evaluations on the important nuclear facilities against the aircraft crash have been reported in other countries. But the condition and the evaluation method to define impact force of aircraft crash have not been described clearly in the reports. In Japan, public concern with the safety evaluation against aircraft crash is increasing. It is important to make clear the behavior of the storage facilities installing the metal casks on impact loading due to aircraft crash. In this study, concerning crash between commercial aircraft and storage facility, impact analysis using dynamic analysis code LS-DYNA has been executed. The results showed that the storage facility was not completely destroyed. But the rigid aircraft engine may penetrate into the storage facility with local failure. Thus, we assumed the engine hit a metal cask in the storage facility and evaluated sealing performance of the metal cask under the impact loading. If the engine with 90m/s crashed the storage facility having concrete wall of 85cm in thickness, the remaining velocity became 60m/s after penetration. We calculated impact force of the engine with 60m/s crashing into the metal cask. Concerning the metal cask loaded the impact force, impact analysis was executed. We assumed two directions of impact force. One is vertical load and another is horizontal load against the cask. The result showed that plastic strain was not generated on flanges of the 1st lid and the sealing performance of the cask was maintained in each impact case. (author)

  2. Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This standard guide defines the process for developing a strategy for dispositioning concrete from nuclear facility decommissioning. It outlines a 10-step method to evaluate disposal options for radioactively contaminated concrete. One of the steps is to complete a detailed analysis of the cost and dose to nonradiation workers (the public); the methodology and supporting data to perform this analysis are detailed in the appendices. The resulting data can be used to balance dose and cost and select the best disposal option. These data, which establish a technical basis to apply to release the concrete, can be used in several ways: (1) to show that the release meets existing release criteria, (2) to establish a basis to request release of the concrete on a case-by-case basis, (3) to develop a basis for establishing release criteria where none exists. 1.2 This standard guide is based on the “Protocol for Development of Authorized Release Limits for Concrete at U.S. Department of Energy Sites,” (1) from ...

  3. Evaluation of users' satisfaction on pedestrian facilities using pair-wise comparison approach

    Science.gov (United States)

    Zainol, R.; Ahmad, F.; Nordin, N. A.; Aripin, A. W. M.

    2014-02-01

    Global climate change issues demand people of the world to change the way they live today. Thus, current cities need to be redeveloped towards less use of carbon in their day to day operations. Pedestrianized environment is one of the approaches used in reducing carbon foot print in cities. Heritage cities are the first to be looked into since they were built in the era in which motorized vehicles were minimal. Therefore, the research explores users' satisfaction on assessment of physical attributes of pedestrianization in Melaka Historical City, a UNESCO World Heritage Site. It aims to examine users' satisfaction on pedestrian facilities provided within the study area using pair wise questionnaire comparison approach. A survey of 200 respondents using random sampling was conducted in six different sites namely Jonker Street, Church Street, Kota Street, Goldsmith Street, Merdeka Street to Taming Sari Tower and Merdeka Street to River Cruise terminal. The survey consists of an assessment tool based on a nine-point scale of users' satisfaction level of pathway properties, zebra pedestrian crossing, street furniture, personal safety, adjacent to traffic flow, aesthetic and amenities. Analytical hierarchical process (AHP) was used to avoid any biasness in analyzing the data collected. Findings show that Merdeka Street to Taming Sari Tower as the street that scores the highest satisfaction level that fulfils all the required needs of a pedestrianized environment. Similar assessment elements can be used to evaluate existing streets in other cities and these criteria should also be used in planning for future cities.

  4. Facile synthesis and antimicrobial evaluation of some new heterocyclic compounds incorporating a biologically active sulfamoyl moiety.

    Science.gov (United States)

    Darwish, Elham S

    2014-01-01

    A facile and convenient synthesis of new heterocyclic compounds containing a sulfamoyl moiety suitable for use as antimicrobial agents was reported. The precursor 3-oxo-3-phenyl-N-(4-sulfamoylphenyl)propionamide was coupled smoothly with arenediazonium salt producing hydrazones which reacted with malononitrile or triethylorthoformate affording pyridazine and triazine derivatives, respectively. Also, the reactivity of the same precursor with DMF-DMA was followed by aminotriazole; aromatic aldehydes was followed by hydrazine hydrate, triethylorthoformate, or thiourea affording triazolo[1,5-a]pyrimidine, pyrazole, acrylamide, and dihydropyrimidine derivatives, respectively. On the other hand, treatment of the precursor propionamide with phenyl isothiocyanate and KOH in DMF afforded the intermediate salt which was treated with dilute HCl followed by 2-bromo-1-phenylethanone affording carboxamide derivative. While the same intermediate salt reacted in situ with chloroacetone, ethyl 2-chloroacetate, 3-(2-bromoacetyl)-2H-chromen-2-one, methyl iodide, or 2-oxo-N-phenylpropane hydrazonoyl chloride afforded the thiophene, ketene N,S-acetal, and thiadiazole derivatives, respectively. The structure of the new products was established based on elemental and spectral analysis. Antimicrobial evaluation of some selected examples from the synthesized products was carried out whereby four compounds were found to have moderate activities and one compound showed the highest activity.

  5. 2727-S Nonradioactive Dangerous Waste Storage Facility clean closure evaluation report

    International Nuclear Information System (INIS)

    Luke, S.N.

    1994-01-01

    This report presents the analytical results of 2727-S NRDWS facility closure verification soil sampling and compares these results to clean closure criteria. The results of this comparison will determine if clean closure of the unit is regulatorily achievable. This report also serves to notify regulators that concentrations of some analytes at the site exceed sitewide background threshold levels (DOE-RL 1993b) and/or the limits of quantitation (LOQ). This report also presents a Model Toxics Control Act Cleanup (MTCA) (WAC 173-340) regulation health-based closure standard under which the unit can clean close in lieu of closure to background levels or LOQ in accordance with WAC 173-303-610. The health-based clean closure standard will be closure to MTCA Method B residential cleanup levels. This report reconciles all analyte concentrations reported above background or LOQ to this health-based cleanup standard. Regulator acceptance of the findings presented in this report will qualify the TSD unit for clean closure in accordance with WAC 173-303-610 without further TSD unit soil sampling, or soil removal and/or decontamination. Nondetected analytes require no further evaluation

  6. Using virtual reality in the training of security staff and evaluation of physical protection barriers in nuclear facilities

    International Nuclear Information System (INIS)

    Augusto, Silas C.; Mol, Antonio C.A.; Mol, Pedro C.; Sales, Douglas S.

    2009-01-01

    The physical security of facilities containing radioactive objects, an already important matter, now has a new aggravating factor: the existence of groups intending to obtain radioactive materials for the purpose of intentionally induce radioactive contamination incidents, as for example the explosion of dirty bombs in populated regions, damaging both people and environment. In this context, the physical security of such facilities must be reinforced so to reduce the possibilities of such incidents. This paper presents a adapted game engine used as a virtual reality system, enabling the modeling and simulation of scenarios of nuclear facilities containing radioactive objects. In these scenarios, the physical protection barriers, as fences and walls, are simulated along with vigilance screens. Using a computer network, several users can participate simultaneously in the simulation, being represented by avatars. Users can play the roles of both invaders and security staff. The invaders have as objective to surpass the facility's physical protection barriers to steal radioactive objects and flee. The security staff have as objective to prevent and stop the theft of radioactive objects from the facility. The system can be used to analysis simulated scenarios and train vigilance/security staff. A test scenario was already developed and used, and the preliminary tests had satisfactory results, as they enabled the evaluation of the physical protection barriers of the virtual facility, and the training of those who participated in the simulations in the functions of a security staff. (author)

  7. Using virtual reality in the training of security staff and evaluation of physical protection barriers in nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Augusto, Silas C.; Mol, Antonio C.A.; Mol, Pedro C.; Sales, Douglas S. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)], e-mail: silas@ien.gov.br, e-mail: mol@ien.gov.br, e-mail: pedro98@gmail.com, e-mail: dsales@ien.gov.br

    2009-07-01

    The physical security of facilities containing radioactive objects, an already important matter, now has a new aggravating factor: the existence of groups intending to obtain radioactive materials for the purpose of intentionally induce radioactive contamination incidents, as for example the explosion of dirty bombs in populated regions, damaging both people and environment. In this context, the physical security of such facilities must be reinforced so to reduce the possibilities of such incidents. This paper presents a adapted game engine used as a virtual reality system, enabling the modeling and simulation of scenarios of nuclear facilities containing radioactive objects. In these scenarios, the physical protection barriers, as fences and walls, are simulated along with vigilance screens. Using a computer network, several users can participate simultaneously in the simulation, being represented by avatars. Users can play the roles of both invaders and security staff. The invaders have as objective to surpass the facility's physical protection barriers to steal radioactive objects and flee. The security staff have as objective to prevent and stop the theft of radioactive objects from the facility. The system can be used to analysis simulated scenarios and train vigilance/security staff. A test scenario was already developed and used, and the preliminary tests had satisfactory results, as they enabled the evaluation of the physical protection barriers of the virtual facility, and the training of those who participated in the simulations in the functions of a security staff. (author)

  8. Design challenges for electronic medication administration record systems in residential aged care facilities: a formative evaluation.

    Science.gov (United States)

    Tariq, A; Lehnbom, E; Oliver, K; Georgiou, A; Rowe, C; Osmond, T; Westbrook, J

    2014-01-01

    Electronic medication administration record (eMAR) systems are promoted as a potential intervention to enhance medication safety in residential aged care facilities (RACFs). The purpose of this study was to conduct an in-practice evaluation of an eMAR being piloted in one Australian RACF before its roll out, and to provide recommendations for system improvements. A multidisciplinary team conducted direct observations of workflow (n=34 hours) in the RACF site and the community pharmacy. Semi-structured interviews (n=5) with RACF staff and the community pharmacist were conducted to investigate their views of the eMAR system. Data were analysed using a grounded theory approach to identify challenges associated with the design of the eMAR system. The current eMAR system does not offer an end-to-end solution for medication management. Many steps, including prescribing by doctors and communication with the community pharmacist, are still performed manually using paper charts and fax machines. Five major challenges associated with the design of eMAR system were identified: limited interactivity; inadequate flexibility; problems related to information layout and semantics; the lack of relevant decision support; and system maintenance issues. We suggest recommendations to improve the design of the eMAR system and to optimize existing workflows. Immediate value can be achieved by improving the system interactivity, reducing inconsistencies in data entry design and offering dedicated organisational support to minimise connectivity issues. Longer-term benefits can be achieved by adding decision support features and establishing system interoperability requirements with stakeholder groups (e.g. community pharmacies) prior to system roll out. In-practice evaluations of technologies like eMAR system have great value in identifying design weaknesses which inhibit optimal system use.

  9. Engineering evaluation cost analysis for the 100-B/C area ancillary facilities at the 108-F Building

    International Nuclear Information System (INIS)

    1996-10-01

    In 1995, the US Department of Energy (DOE), Richland Operations Office (RL) conducted a removal site evaluation of selected facilities in the 100 Area of the Hanford Site in accordance with CERCLA and 40 Code of Federal Regulations (CFR) 300.410. The scope of the evaluation included the aboveground portions of the 108-F Biology Laboratory in the 100-F Area and all inactive ancillary buildings and structures in the 100-B/C Area, excluding the reactor building and the river outfall. Based on the evaluation, RL determined that hazardous substances in the 108-F Biology Laboratory and five of the 100-B/C Area facilities may present a potential threat to human health or the environment, and that a non-time critical removal action at these facilities is warranted. This determination was documented in an engineering evaluation/cost analysis (EE/CA) approval memorandum. The EE/CA approval memorandum is the basis on which to proceed with the performance of an EE/CA to determine the appropriate removal action. This report presents the results of the EE/CA for removal alternatives for final disposition of these six facilities. The EE/CA was conducted pursuant to the requirements of CERCLA and 40 CFR 300.415 and is intended to aid RL and the EPA in selecting a preferred removal action

  10. Evaluation of a prototype air transport system for use in a crate handling and size reduction facility

    International Nuclear Information System (INIS)

    Kennedy, S.T.

    1987-01-01

    This paper describes in detail the design features and evaluation, under simulated active conditions, of a purpose designed remotely operated air transporter system. The paper concludes by recommending that an air transporter, based on this concept, is considered for the alpha active facility. (author)

  11. Evaluation of a prototype air transport system for use in a crate handling and size reduction facility

    International Nuclear Information System (INIS)

    Kennedy, S.T.

    1987-09-01

    This paper describes the design features and evaluation, under simulated active conditions, of a purpose designed remotely operated air transporter system. The paper concludes by recommending that an air transporter, based on this concept, is considered for the alpha active facility. (author)

  12. Hazard Evaluation for Storage of Spent Nuclear Fuel (SNF) Sludge at the Solid Waste Treatment Facility

    International Nuclear Information System (INIS)

    SCHULTZ, M.V.

    2000-01-01

    As part of the Spent Nuclear Fuel (SNF) storage basin clean-up project, sludge that has accumulated in the K Basins due to corrosion of damaged irradiated N Reactor will be loaded into containers and placed in interim storage. The Hanford Site Treatment Complex (T Plant) has been identified as the location where the sludge will be stored until final disposition of the material occurs. Long term storage of sludge from the K Basin fuel storage facilities requires identification and analysis of potential accidents involving sludge storage in T Plant. This report is prepared as the initial step in the safety assurance process described in DOE Order 5480.23, Nuclear Safety Analysis Reports and HNF-PRO-704, Hazards and Accident Analysis Process. This report documents the evaluation of potential hazards and off-normal events associated with sludge storage activities. This information will be used in subsequent safety analyses, design, and operations procedure development to ensure safe storage. The hazards evaluation for the storage of SNF sludge in T-Plant used the Hazards and Operability Analysis (HazOp) method. The hazard evaluation identified 42 potential hazardous conditions. No hazardous conditions involving hazardous/toxic chemical concerns were identified. Of the 42 items identified in the HazOp study, eight were determined to have potential for onsite worker consequences. No items with potential offsite consequences were identified in the HazOp study. Hazardous conditions with potential onsite worker or offsite consequences are candidates for quantitative consequence analysis. The hazardous conditions with potential onsite worker consequences were grouped into two event categories, Container failure due to overpressure - internal to T Plant, and Spill of multiple containers. The two event categories will be developed into accident scenarios that will be quantitatively analyzed to determine release consequences. A third category, Container failure due to

  13. Safety evaluation report of hot cell facilities for demonstration of advanced spent fuel conditioning process

    International Nuclear Information System (INIS)

    You, Gil Sung; Choung, W. M.; Ku, J. H.; Cho, I. J.; Kook, D. H.; Park, S. W.; Bek, S. Y.; Lee, E. P.

    2004-10-01

    The advanced spent fuel conditioning process(ACP) proposed to reduce the overall volume of the PWR spent fuel and improve safety and economy of the long-term storage of spent fuel. In the next phase(2004∼2006), the hot test will be carried out for verification of the ACP in a laboratory scale. For the hot test, the hot cell facilities of α- type and auxiliary facilities are required essentially for safe handling of high radioactive materials. As the hot cell facilities for demonstration of the ACP, a existing hot cell of β- type will be refurbished to minimize construction expenditures of hot cell facility. Up to now, the detail design of hot cell facilities and process were completed, and the safety analysis was performed to substantiate secure of conservative safety. The design data were submitted for licensing which was necessary for construction and operation of hot cell facilities. The safety investigation of KINS on hot cell facilities was completed, and the license for construction and operation of hot cell facilities was acquired already from MOST. In this report, the safety analysis report submitted to KINS was summarized. And also, the questionnaires issued from KINS and answers of KAERI in process of safety investigation were described in detail

  14. A human factors engineering evaluation of the Multi-Function Waste Tank Facility. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Donohoo, D.T. [Pacific Northwest Lab., Richland, WA (United States); Sarver, T.L. [ARES Corp., San Francisco, CA (United States)

    1995-06-05

    This report documents the methods and results of a human factors engineering (HFE) review conducted on the Multi-Function Waste Tank Facility (MWTF), Westinghouse Hanford Company (WHC) Project 236A, to be constructed at the U.S. Department of Energy (DOE) facility at Hanford, Washington. This HFE analysis of the MWTF was initiated by WHC to assess how well the current facility and equipment design satisfies the needs of its operations and maintenance staff and other potential occupants, and to identify areas of the design that could benefit from improving the human interfaces at the facility. Safe and effective operations, including maintenance, is a primary goal for the MWTF. Realization of this goal requires that the MWTF facility, equipment, and operations be designed in a manner that is consistent with the abilities and limitations of its operating personnel. As a consequence, HFE principles should be applied to the MWTF design, construction, its operating procedures, and its training. The HFE review was focused on the 200-West Area facility as the design is further along than that of the 200-East Area. The review captured, to the greatest extent feasible at this stage of design, all aspects of the facility activities and included the major topics generally associated with HFE (e.g., communication, working environment). Lessons learned from the review of the 200 West facility will be extrapolated to the 200-East Area, as well as generalized to the Hanford Site.

  15. A human factors engineering evaluation of the Multi-Function Waste Tank Facility. Final report

    International Nuclear Information System (INIS)

    Donohoo, D.T.; Sarver, T.L.

    1995-01-01

    This report documents the methods and results of a human factors engineering (HFE) review conducted on the Multi-Function Waste Tank Facility (MWTF), Westinghouse Hanford Company (WHC) Project 236A, to be constructed at the U.S. Department of Energy (DOE) facility at Hanford, Washington. This HFE analysis of the MWTF was initiated by WHC to assess how well the current facility and equipment design satisfies the needs of its operations and maintenance staff and other potential occupants, and to identify areas of the design that could benefit from improving the human interfaces at the facility. Safe and effective operations, including maintenance, is a primary goal for the MWTF. Realization of this goal requires that the MWTF facility, equipment, and operations be designed in a manner that is consistent with the abilities and limitations of its operating personnel. As a consequence, HFE principles should be applied to the MWTF design, construction, its operating procedures, and its training. The HFE review was focused on the 200-West Area facility as the design is further along than that of the 200-East Area. The review captured, to the greatest extent feasible at this stage of design, all aspects of the facility activities and included the major topics generally associated with HFE (e.g., communication, working environment). Lessons learned from the review of the 200 West facility will be extrapolated to the 200-East Area, as well as generalized to the Hanford Site

  16. Evaluation of environmental control technologies for commercial uranium nuclear fuel fabrication facilities

    International Nuclear Information System (INIS)

    Perkins, B.L.

    1983-01-01

    At present in the United States, there are seven commercial light-water reactor uranium fuel fabrication facilities. Effluent wastes from these facilities include uranium, nitrogen, fluorine, and organic-containing compounds. These effluents may be either discharged to the ambient environment, treated and recycled internally, stored or disposed of on-site, sent off-site for treatment and/or recovery, or sent off-site for disposal (including disposal in low-level waste burial sites). Quantities of waste generated and treatment techniques vary greatly depending on the facility and circuits used internally at the facility, though in general all the fluorine entering the facility as UF 6 is discharged as waste. Further studies to determine techniques and procedures that might minimize dose (ALARA) and to give data on possible long-term effects of effluent discharge and waste disposal are needed

  17. Hyperspectral Imaging and K-Means Classification for Histologic Evaluation of Ductal Carcinoma In Situ

    Directory of Open Access Journals (Sweden)

    Yasser Khouj

    2018-02-01

    Full Text Available Hyperspectral imaging (HSI is a non-invasive optical imaging modality that shows the potential to aid pathologists in breast cancer diagnoses cases. In this study, breast cancer tissues from different patients were imaged by a hyperspectral system to detect spectral differences between normal and breast cancer tissues. Tissue samples mounted on slides were identified from 10 different patients. Samples from each patient included both normal and ductal carcinoma tissue, both stained with hematoxylin and eosin stain and unstained. Slides were imaged using a snapshot HSI system, and the spectral reflectance differences were evaluated. Analysis of the spectral reflectance values indicated that wavelengths near 550 nm showed the best differentiation between tissue types. This information was used to train image processing algorithms using supervised and unsupervised data. The K-means method was applied to the hyperspectral data cubes, and successfully detected spectral tissue differences with sensitivity of 85.45%, and specificity of 94.64% with true negative rate of 95.8%, and false positive rate of 4.2%. These results were verified by ground-truth marking of the tissue samples by a pathologist. In the hyperspectral image analysis, the image processing algorithm, K-means, shows the greatest potential for building a semi-automated system that could identify and sort between normal and ductal carcinoma in situ tissues.

  18. Prometheus unbound - challenges of risk evaluation, risk classification, and risk management

    Energy Technology Data Exchange (ETDEWEB)

    Klinke, A.; Renn, O.

    1999-11-01

    For dealing with risks in a rational fashion, it is necessary to characterize risks and use the parameters of characterization as tools for designing appropriate actions. This reports suggests a set of criteria that one can use in evaluating risks. These criteria include: - Damage potential, i.e. the amount of damage that the hazard can cause; - probability of occurrence, i.e. the likelihood that a specific damage will occur; - incertitude, i.e., the remaining uncertainties that are not covered by the assessment of probabilities (subdivided in statistical uncertainties, genuine uncertainty, and ignorance); - ubiquity which defines the geographic dispersion of potential damages (intragenerational justice); - persistency which defines the temporal extension of potential damages (intergenerational justice); - irreversibility which describes the impossible restoration of the situation to the state before the damage occurred (possible restoration are e.g. reforestation and cleaning of water); - delay effects which characterize the time of latency between the initial event and the actual impact of damage. The time of latency could be of physical, chemical or biological nature; and - potential of mobilization which is understood as violation of individual, social or cultural interests and values generating social conflicts and psychological reactions by affected people. (orig.)

  19. Hyperspectral Imaging and K-Means Classification for Histologic Evaluation of Ductal Carcinoma In Situ.

    Science.gov (United States)

    Khouj, Yasser; Dawson, Jeremy; Coad, James; Vona-Davis, Linda

    2018-01-01

    Hyperspectral imaging (HSI) is a non-invasive optical imaging modality that shows the potential to aid pathologists in breast cancer diagnoses cases. In this study, breast cancer tissues from different patients were imaged by a hyperspectral system to detect spectral differences between normal and breast cancer tissues. Tissue samples mounted on slides were identified from 10 different patients. Samples from each patient included both normal and ductal carcinoma tissue, both stained with hematoxylin and eosin stain and unstained. Slides were imaged using a snapshot HSI system, and the spectral reflectance differences were evaluated. Analysis of the spectral reflectance values indicated that wavelengths near 550 nm showed the best differentiation between tissue types. This information was used to train image processing algorithms using supervised and unsupervised data. The K-means method was applied to the hyperspectral data cubes, and successfully detected spectral tissue differences with sensitivity of 85.45%, and specificity of 94.64% with true negative rate of 95.8%, and false positive rate of 4.2%. These results were verified by ground-truth marking of the tissue samples by a pathologist. In the hyperspectral image analysis, the image processing algorithm, K-means, shows the greatest potential for building a semi-automated system that could identify and sort between normal and ductal carcinoma in situ tissues.

  20. Neural network classification technique and machine vision for bread crumb grain evaluation

    Science.gov (United States)

    Zayas, Inna Y.; Chung, O. K.; Caley, M.

    1995-10-01

    Bread crumb grain was studied to develop a model for pattern recognition of bread baked at Hard Winter Wheat Quality Laboratory (HWWQL), Grain Marketing and Production Research Center (GMPRC). Images of bread slices were acquired with a scanner in a 512 multiplied by 512 format. Subimages in the central part of the slices were evaluated by several features such as mean, determinant, eigen values, shape of a slice and other crumb features. Derived features were used to describe slices and loaves. Neural network programs of MATLAB package were used for data analysis. Learning vector quantization method and multivariate discriminant analysis were applied to bread slices from what of different sources. A training and test sets of different bread crumb texture classes were obtained. The ranking of subimages was well correlated with visual judgement. The performance of different models on slice recognition rate was studied to choose the best model. The recognition of classes created according to human judgement with image features was low. Recognition of arbitrarily created classes, according to porosity patterns, with several feature patterns was approximately 90%. Correlation coefficient was approximately 0.7 between slice shape features and loaf volume.

  1. [Evaluation and classification of drug therapy for breast cancer with bone-only metastasis].

    Science.gov (United States)

    Meng, X Y; Song, S T

    2017-03-23

    Skeleton is one of the most common metastatic organs for breast cancer, which has a better prognosis than visceral metastases. Bone-only metastasis was defined"non-measurable" in the RECIST (Response Evaluation Criteria in Solid Tumors) criteria, and was excluded by clinical trials. However, patients with bone-only metastasis are also in need of effective treatment to prolong survival. Endocrine therapy is the most important treatment for bone metastatic patients. Tumor response of bone metastases can be determined objectively by bone-window CT. Effective treatment should be continued if the symptoms are relieved or osteogenesis is observed. Osteoblastic change in bone-window CT is a sign of improvement after treatment. Endocrine therapy is proper for ER-positive patients. The patients with initial osteoblastic metastasis should not be treated with salvage chemotherapy or anti-HER2 treatment, only if osteolytic metastasis or visceral metastasis is observed. Bishosphonates are just auxiliary drugs in bone metastasis, which should not be abused.

  2. Removal site evaluation report on the bulk shielding facility at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-09-01

    This removal site evaluation report on the Bulk Shielding Facility (BSF) at Oak Ridge National Laboratory was prepared to provide the Environmental Restoration Program with information necessary to evaluate whether hazardous and/or radiological contaminants in and around BSF buildings pose a substantial risk to human health or the environment (i.e., a high probability of adverse effects) and whether remedial site evaluations or removal actions are, therefore, required. A removal site evaluation was conducted at nine areas associated with the BSF. The scope of each evaluation included (1) a search for, and review of, readily available historical records regarding operations and use of the facility (including hazardous substance usage and existing contamination); (2) interviews with facility personnel concerning current and past practices; and (3) a brief walk-through to visually inspect the facility and identify existing hazard areas requiring maintenance actions or remedial evaluation. The results of the removal site evaluation indicate that no substantial risks exist from contaminants present because adequate efforts are being made to contain and control existing contamination and hazardous substances and to protect human health and the environment. At Building 3004, deteriorated and peeling exterior paint has a direct pathway to the storm water drainage system and can potentially impact local surface water during periods of storm water runoff. The paint is assumed to be lead based, thus posing a potential problem. The paint should be sampled and analyzed to determine its lead content and to assess whether a hazard exists. If so, a maintenance action will be necessary to prevent further deterioration and dislodging of the paint. In addition, if the paint contains lead, then a remedial site evaluation should be conducted to determine whether lead from fallen chips has impacted soils in the immediate area of the building

  3. 20th International Training Course (ITC-20) on the physical protection of nuclear facilities and materials evaluation report.

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, Amanda Ann

    2008-09-01

    The goal of this evaluation report is to provide the information necessary to improve the effectiveness of the ITC provided to the International Atomic Energy Agency Member States. This report examines ITC-20 training content, delivery methods, scheduling, and logistics. Ultimately, this report evaluates whether the course provides the knowledge and skills necessary to meet the participants needs in the protection of nuclear materials and facilities.

  4. Facilities Programming.

    Science.gov (United States)

    Bullis, Robert V.

    1992-01-01

    A procedure for physical facilities management written 17 years ago is still worth following today. Each of the steps outlined for planning, organizing, directing, controlling, and evaluating must be accomplished if school facilities are to be properly planned and constructed. However, lessons have been learned about energy consumption and proper…

  5. Measurement, Classification and Evaluation of Sleep Disturbance in Psoriasis: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Alasdair L Henry

    Full Text Available Psoriasis is a long-term immune-mediated inflammatory disorder mainly, but not only, affecting skin, and is associated with significant medical and psychological morbidity. Evidence suggests that sleep is disrupted in psoriasis, however high quality empirical evidence is lacking. Given the importance of sleep for health, characterisation of sleep disruption in psoriasis is an important goal. We therefore conducted a systematic review of the sleep-psoriasis literature.Searches were conducted in Pubmed, SCOPUS and Web of Science from inception to May 2016. Studies were compared against inclusion/exclusion criteria and underwent a quality evaluation. Given the heterogeneity of studies, we conducted a narrative synthesis of the findings.Searches revealed 32 studies which met our predetermined inclusion/exclusion criteria. Whilst 93.7% of studies reported sleep disruption in this population, ranging from 0.05% to 85.4%, many had important methodological shortcomings. Over half of all quantitative studies (54.8%; 17/31 relied on non-validated measures, contributing to heterogeneity in study findings. In those that employed valid measures, assessing sleep was often not the primary objective. We frequently found the absence of adequate sample size calculations and poor statistical reporting.This review showed that in psoriasis, reported sleep rates of sleep disturbance varied substantially. Most studies lacked a hypothesis driven research question and/or failed to use validated measures of sleep. We were unable to draw firm conclusions about the precise prevalence and nature of sleep disturbance within the psoriasis population. We offer suggestions to help advance understanding of sleep disturbance in psoriasis.

  6. [Evaluation of the capacity of the APR-DRG classification system to predict hospital mortality].

    Science.gov (United States)

    De Marco, Maria Francesca; Lorenzoni, Luca; Addari, Piero; Nante, Nicola

    2002-01-01

    Inpatient mortality has increasingly been used as an hospital outcome measure. Comparing mortality rates across hospitals requires adjustment for patient risks before making inferences about quality of care based on patient outcomes. Therefore it is essential to dispose of well performing severity measures. The aim of this study is to evaluate the ability of the All Patient Refined DRG system to predict inpatient mortality for congestive heart failure, myocardial infarction, pneumonia and ischemic stroke. Administrative records were used in this analysis. We used two statistics methods to assess the ability of the APR-DRG to predict mortality: the area under the receiver operating characteristics curve (referred to as the c-statistic) and the Hosmer-Lemeshow test. The database for the study included 19,212 discharges for stroke, pneumonia, myocardial infarction and congestive heart failure from fifteen hospital participating in the Italian APR-DRG Project. A multivariate analysis was performed to predict mortality for each condition in study using age, sex and APR-DRG risk mortality subclass as independent variables. Inpatient mortality rate ranges from 9.7% (pneumonia) to 16.7% (stroke). Model discrimination, calculated using the c-statistic, was 0.91 for myocardial infarction, 0.68 for stroke, 0.78 for pneumonia and 0.71 for congestive heart failure. The model calibration assessed using the Hosmer-Leme-show test was quite good. The performance of the APR-DRG scheme when used on Italian hospital activity records is similar to that reported in literature and it seems to improve by adding age and sex to the model. The APR-DRG system does not completely capture the effects of these variables. In some cases, the better performance might be due to the inclusion of specific complications in the risk-of-mortality subclass assignment.

  7. 10 CFR 61.55 - Waste classification.

    Science.gov (United States)

    2010-01-01

    ... REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR LAND DISPOSAL OF RADIOACTIVE WASTE Technical Requirements for Land Disposal Facilities § 61.55 Waste classification. (a) Classification of waste for near surface disposal—(1) Considerations. Determination of the classification of radioactive waste involves two...

  8. Systems Design and Experimental Evaluation of a High-Altitude Relight Test Facility

    Science.gov (United States)

    Paxton, Brendan

    Novel advances in gas turbine engine combustor technology, led by endeavors into fuel efficiency and demanding environmental regulations, have been fraught with performance and safety concerns. While the majority of low emissions gas turbine engine combustor technology has been necessary for power generation applications, the push for ultra-low NOx combustion in aircraft jet engines has been ever present. Recent state-of-the-art combustor designs notably tackle historic emissions challenges by operating at fuel-lean conditions, which are characterized by an increase in the amount of air flow sent to the primary combustion zone. While beneficial in reducing NOx emissions, the fuel-lean mechanisms that characterize these combustor designs rely heavily upon high-energy and high-velocity air flows to sufficiently mix and atomize fuel droplets, ultimately leading to flame stability concerns during low-power operation. When operating at high-altitude conditions, these issues are further exacerbated by the presence of low ambient air pressures and temperatures, which can lead to engine flame-out situations and hamper engine relight attempts. To aid academic and industrial research ventures into improving the high-altitude lean blow-out and relight performance of modern gas turbine engine combustor technologies, the High-Altitude Relight Test Facility (HARTF) was designed and constructed at the University of Cincinnati (UC) Combustion and Fire Research Laboratory (CFRL). Following its construction, an experimental evaluation of its abilities to facilitate optically-accessible ignition, combustion, and spray testing for gas turbine engine combustor hardware at simulated high-altitude conditions was performed. In its evaluation, performance limit references were established through testing of the HARTF vacuum and cryogenic air-chilling capabilities. These tests were conducted with regard to end-user control---the creation and the maintenance of a realistic high

  9. Design of a cryogenic test facility for evaluating the performance of interferometric components of the SPICA/SAFARI instrument

    Science.gov (United States)

    Veenendaal, Ian T.; Naylor, David A.; Gom, Brad G.

    2014-08-01

    The Japanese SPace Infrared telescope for Cosmology and Astrophysics (SPICA), a 3 m class telescope cooled to ~ 6 K, will provide extremely low thermal background far-infrared observations. An imaging Fourier transform spectrometer (SAFARI) is being developed to exploit the low background provided by SPICA. Evaluating the performance of the interferometer translation stage and key optical components requires a cryogenic test facility. In this paper we discuss the design challenges of a pulse tube cooled cryogenic test facility that is under development for this purpose. We present the design of the cryostat and preliminary results from component characterization and external optical metrology.

  10. A Web-Based, Hospital-Wide Health Care-Associated Bloodstream Infection Surveillance and Classification System: Development and Evaluation.

    Science.gov (United States)

    Tseng, Yi-Ju; Wu, Jung-Hsuan; Lin, Hui-Chi; Chen, Ming-Yuan; Ping, Xiao-Ou; Sun, Chun-Chuan; Shang, Rung-Ji; Sheng, Wang-Huei; Chen, Yee-Chun; Lai, Feipei; Chang, Shan-Chwen

    2015-09-21

    Surveillance of health care-associated infections is an essential component of infection prevention programs, but conventional systems are labor intensive and performance dependent. To develop an automatic surveillance and classification system for health care-associated bloodstream infection (HABSI), and to evaluate its performance by comparing it with a conventional infection control personnel (ICP)-based surveillance system. We developed a Web-based system that was integrated into the medical information system of a 2200-bed teaching hospital in Taiwan. The system automatically detects and classifies HABSIs. In this study, the number of computer-detected HABSIs correlated closely with the number of HABSIs detected by ICP by department (n=20; r=.999 Psystem performed excellently with regard to sensitivity (98.16%), specificity (99.96%), positive predictive value (95.81%), and negative predictive value (99.98%). The system enabled decreasing the delay in confirmation of HABSI cases, on average, by 29 days. This system provides reliable and objective HABSI data for quality indicators, improving the delay caused by a conventional surveillance system.

  11. Using Procedure Based on Item Response Theory to Evaluate Classification Consistency Indices in the Practice of Large-Scale Assessment

    Directory of Open Access Journals (Sweden)

    Shanshan Zhang

    2017-09-01

    Full Text Available In spite of the growing interest in the methods of evaluating the classification consistency (CC indices, only few researches are available in the field of applying these methods in the practice of large-scale educational assessment. In addition, only few studies considered the influence of practical factors, for example, the examinee ability distribution, the cut score location and the score scale, on the performance of CC indices. Using the newly developed Lee's procedure based on the item response theory (IRT, the main purpose of this study is to investigate the performance of CC indices when practical factors are taken into consideration. A simulation study and an empirical study were conducted under comprehensive conditions. Results suggested that with negatively skewed distribution, the CC indices were larger than with other distributions. Interactions occurred among ability distribution, cut score location, and score scale. Consequently, Lee's IRT procedure is reliable to be used in the field of large-scale educational assessment, and when reporting the indices, it should be treated with caution as testing conditions may vary a lot.

  12. Laser therapy in pressure ulcers: evaluation by the Pressure Ulcer Scale for Healing and Nursing Outcomes Classification

    Directory of Open Access Journals (Sweden)

    Sofia Palagi

    2015-10-01

    Full Text Available AbstractOBJECTIVETo describe the pressure ulcer healing process in critically ill patients treated with conventional dressing therapy plus low-intensity laser therapy evaluated by the Pressure Ulcer Scale for Healing (PUSH and the result of Wound Healing: Secondary Intention, according to the Nursing Outcomes Classification (NOC.METHODCase report study according to nursing process conducted with an Intensive Care Unit patient. Data were collected with an instrument containing the PUSH and the result of the NOC. In the analysis we used descriptive statistics, considering the scores obtained on the instrument.RESULTSA reduction in the size of lesions of 7cm to 1.5cm of length and 6cm to 1.1cm width, in addition to the increase of epithelial tissue and granulation, decreased secretion and odor.CONCLUSIONThere was improvement in the healing process of the lesion treated with adjuvant therapy and the use of NOC allowed a more detailed and accurate assessment than the PUSH.

  13. Tc-99m GSA scintigraphy for evaluation of liver function. Correlations with histological grading and staging (new Inuyama classification)

    International Nuclear Information System (INIS)

    Endo, Ikuyo; Ohashi, Kenjirou; Fukui, Atsushi; Nikai, Akira; Maeyama, Shiro

    2001-01-01

    To evaluate the parameters of Tc-99m galactosyl human serum albumin (Tc-99m GSA) as indicators of residual liver function by comparing with laboratory data and histological grading and staging. The study population consists of 82 patients with liver diseases including chronic hepatitis (60), compensated liver cirrhosis (12) and decompensated liver cirrhosis (10). Five parameters of Tc-99m GSA (HH 15 , LHL 15 , LHL/HH, ncEI 5 and EI 5 ) were measured and correlated with laboratory data and histological grading, which indicates necro-inflammatory activity, and staging, which indicates fibrosis (New Inuyama Classification). All 5 parameters showed significant correlation with the laboratory data for liver function including serum albumin, platelet count, and prothrombin time. LHL 15 showed a particularly strong correlation with serum albumin, total bilirubin, TTT, ZTT, and prothrombin time. Regarding histological correlation, only LHL 15 showed a significant correlation with both histological grading and staging. HH 15 and LHL/HH revealed significant correlations with staging only. Extraction indexes were not correlated significantly with histological grading and staging. Among the five parameters we tested, LHL 15 is the most potent indicator of liver function. HH 15 , LHL 15 and LHL/HH appear-useful to non-invasive assess histological fibrosis of the liver non-invasively. (author)

  14. orphological Evaluation and Classification of Melon Genotypes in Khorasan Provinces (Razavi, North and South

    Directory of Open Access Journals (Sweden)

    Aireza sobhany

    2017-08-01

    Full Text Available Introduction: Melon is a tropical species that originates from Iran or Africa and Iran, Afghanistan, Turkey, Russia, Saudi Arabia, India and China are the most important centers of genetic diversity of cultivated varieties (1. The original area for cantaloupe and melon is Iran. Dry and warm climate is the best condition for Melon. This plant needs heat and light for good grows. Cloudy and rainy weather at the time of fruit ripening may affect melon taste and quality(2. According to the FAO statistics in 2012, the total area devoted to melon was 1,339,006 hectares with an average yield of 23.8 tons per hectare and 31,925,787 tons production. The highest production belonged to China (55% of world production. Iran produces about 5.4 percent of world production which is about 1450000 tons from 80,000 hectares (2. Recently, a great number of studies have studied the correlation between melon yield and its components. The first branch (5, the number of primary branches, the number of fruits per plant and fruit weight per plant (6, length and width of fruit and fruit shape index were the most important melons traits which have been evaluated by other studies (4. Fruit yield has significant positive correlation with the length of the stem, primary branches, the date of the first appearance of female flowers and fruit weight. Studies revealed that there is a negative correlation between the number of fruits per plant and the average fruit weight. Materials and Methods: This study was conducted in 2008 with 17 landrace seeds collected from different locations of Khorasan provinces included Kashmar, sarakhs, Boshruye, Sabzevar, Dargaz and Bajestan. Experiment was designed based on randomized complete block design with three replications at agricultural Research Station of Khorasan Razavi. Results and Discussion: The cultivars did not show any different in the time of emergence as all of them emerged 4 to 7 days after the first irrigation. The comparison

  15. EVALUATION OF ATTITUDES TOWARDS OLD AGE AMONG OLDER ADULTS IN AN INSTITUTIONAL FACILITY

    Directory of Open Access Journals (Sweden)

    Pavlína Urbanová

    2017-03-01

    Full Text Available Aim: The aim of the research was to determine attitudes towards old age in older adults living in institutional facilities, and to compare them with the population standard. A further aim was to determine differences in attitudes towards old age by gender, age, level of education, and self-sufficiency in the older adults surveyed. Design: A cross-sectional study. Methods: A research sample consisting of 121 elderly people living in retirement homes. Data were collected using a Czech version of the AAQ questionnaire (Attitudes to Ageing Questionnaire, and Barthelʼs test of Activities of daily living was used to assess levels of self-sufficiency. Results: Older adults awarded the highest score (most positive attitude in the domain of psychosocial losses. In comparison with the population standard, older adults rated the domain of physical change (p < 0.001 and psychological growth (p < 0.001 negatively. The domain of psychosocial losses was assessed more positively by men (p < 0.001 and the elderly with moderate dependence (p < 0.001; the domain of physical changes was also positively assessed by men (p = 0.001, and older adults with university education (p = 0.002; the domain of psychological growth was rated more positively by adults over 85 years (p = 0.001, and the elderly with basic education (p = 0.040. Conclusion: Determining older adults´ attitudes towards ageing in institutional care may help in the preparation of individual care plans aimed at supporting clients in areas that have been evaluated negatively. Keywords: institutional care, quality of life, attitudes, old age, ageing, self-sufficiency.

  16. A Fisheries Evaluation of the Richland and Wapato Canal Fish Screening Facilities, Spring 1987 : Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Neitzel, Duane A.; Abernethy, C.Scott; Lusty, E.William; Wampler, Sally J.

    1988-02-01

    We evaluated the effectiveness of new fish screening facilities at the Richland and Wapato canals in south-central Washington State. The screen integrity tests at the Richland Screens indicated that 100% of fall chinook salmon fry (Oncorhynchus tshawytscha) released in front of the screens were prevented from entering the canal behind the screens. Our estimate is based on a 61% catch efficiency for control fish planted behind the screens. At the Wapato Canal, we estimated that between 3% and 4% of the test fish were either impinged on the screen surface and passed over the screens or passed through faulty screen seals. Our estimate is based over the screens or passed through faulty screen seals. Our estimate is based on a greater than 90% capture of control fish released in front of the screens. At the Wapato Screens, we estimated that 0.8% of steelhead smolts (Salmo gairdneri) and 1.4% of spring chinook salmon smolts released during low canal flow tests wee descaled. During full canal flow tests, 1.6% of the steelhead and 3.1% of the spring chinook salmon released were descaled. The fish return pipe at the Wapato Canal was tested: the estimate of descaled test fish wa not different from the estimate of descaled control fish. The time required for fish to exit from the Wapato Screen forebay varied with species and with canal flow. During low canal flows, 43.2% of steelhead and 61.6% of spring chinook salmon smolts released at the trash racks were captured in the fish return within 96 hr. 11 refs., 11 figs., 10 tabs.

  17. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  18. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  19. Evaluation of users' satisfaction on pedestrian facilities using pair-wise comparison approach

    International Nuclear Information System (INIS)

    Zainol, R; Ahmad, F; Nordin, N A; Aripin, A W M

    2014-01-01

    Global climate change issues demand people of the world to change the way they live today. Thus, current cities need to be redeveloped towards less use of carbon in their day to day operations. Pedestrianized environment is one of the approaches used in reducing carbon foot print in cities. Heritage cities are the first to be looked into since they were built in the era in which motorized vehicles were minimal. Therefore, the research explores users' satisfaction on assessment of physical attributes of pedestrianization in Melaka Historical City, a UNESCO World Heritage Site. It aims to examine users' satisfaction on pedestrian facilities provided within the study area using pair wise questionnaire comparison approach. A survey of 200 respondents using random sampling was conducted in six different sites namely Jonker Street, Church Street, Kota Street, Goldsmith Street, Merdeka Street to Taming Sari Tower and Merdeka Street to River Cruise terminal. The survey consists of an assessment tool based on a nine-point scale of users' satisfaction level of pathway properties, zebra pedestrian crossing, street furniture, personal safety, adjacent to traffic flow, aesthetic and amenities. Analytical hierarchical process (AHP) was used to avoid any biasness in analyzing the data collected. Findings show that Merdeka Street to Taming Sari Tower as the street that scores the highest satisfaction level that fulfils all the required needs of a pedestrianized environment. Similar assessment elements can be used to evaluate existing streets in other cities and these criteria should also be used in planning for future cities

  20. Criticality safety evaluation report for the Cold Vacuum Drying Facility's process water handling system

    International Nuclear Information System (INIS)

    Roblyer, S.D.

    1998-01-01

    This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility (CVDF). The controls and limitations on equipment design and operations to control potential criticality occurrences are identified. The effectiveness of equipment design and operation controls in preventing criticality occurrences during normal and abnormal conditions is evaluated and documented in this report. Spent nuclear fuel (SNF) is removed from existing canisters in both the K East and K West Basins and loaded into a multicanister overpack (MCO) in the K Basin pool. The MCO is housed in a shipping cask surrounded by clean water in the annulus between the exterior of the MCO and the interior of the shipping cask. The fuel consists of spent N Reactor and some single pass reactor fuel. The MCO is transported to the CVDF near the K Basins to remove process water from the MCO interior and from the shipping cask annulus. After the bulk water is removed from the MCO, any remaining free liquid is removed by drawing a vacuum on the MCO's interior. After cold vacuum drying is completed, the MCO is filled with an inert cover gas, the lid is replaced on the shipping cask, and the MCO is transported to the Canister Storage Building. The process water removed from the MCO contains fissionable materials from metallic uranium corrosion. The process water from the MCO is first collected in a geometrically safe process water conditioning receiver tank. The process water in the process water conditioning receiver tank is tested, then filtered, demineralized, and collected in the storage tank. The process water is finally removed from the storage tank and transported from the CVDF by truck

  1. Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radiosurgical facilities

    International Nuclear Information System (INIS)

    Cardenas, Jose Patricio Nahuel

    2010-01-01

    The main objective of this research is the dosimetric evaluation of semiconductor components (surface barrier detectors and PIN photodiodes) for applications in dose equivalent measurements on low dose fields (fast and thermal fluxes) using an AmBe neutron source, the IEA-R1 reactor neutrongraphy facility (epithermal and thermal fluxes) and the Critical Unit facility IPEN/MB-01 (fast fluxes). As moderator compound to fast neutrons flux from the AmBe source was used paraffin and boron and polyethylene as converter for thermal and fast neutrons measurements. The resulting fluxes were used to the irradiation of semiconductor components (SSB - Surface Barrier Detector and PIN photodiodes). A mixed converter made of a borated polyethylene foil (Kodak) was also used. Monte Carlo simulation methodology was employed to evaluate analytically the optimal paraffin thickness. The obtained results were similar to the experimental data and allowed the evaluation of emerging neutron flux from moderator, as well as the fast neutron flux reaching the polyethylene covering the semiconductor sensitive surface. Gamma radiation levels were evaluated covering the whole detector with cadmium foil 1 mm thick, allowing thermal neutrons blockage and gamma radiation measurements. The IPEN/MB-01 facility was employed to evaluate the detector response for high neutron flux. The results were in good agreement with other studies published. Using the obtained spectra an approach to dose equivalent calculation was established. (author)

  2. JOINT INTELLIGENCE, SURVEILLANCE, & RECONNAISSANCE (ISR) TEST & EVALUATION (JISR-TE) FACILITY

    Data.gov (United States)

    Federal Laboratory Consortium — To meet the needs of the Warfighter, the JISR-TE facility provides the US, NATO, and Coalition members standards conformance testing of imagery capabilities across...

  3. Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facility's Process Water Handling System

    International Nuclear Information System (INIS)

    KESSLER, S.F.

    2000-01-01

    This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified

  4. Criticality safety evaluation report for the cold vacuum drying facility's process water handling system

    International Nuclear Information System (INIS)

    NELSON, J.V.

    1999-01-01

    This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified

  5. Application of an infiltration evaluation methodology to a hypothetical low-level waste disposal facility

    International Nuclear Information System (INIS)

    Meyer, P.D.

    1993-12-01

    This report provides an analysis of infiltration and percolation at a hypothetical low-level waste (LLW) disposal facility was carried out. The analysis was intended to illustrate general issues of concern in assessing the performance of LLW disposal facilities. Among the processes considered in the analysis were precipitation, runoff, information, evaporation, transpiration, and redistribution. The hypothetical facility was located in a humid environment characterized by frequent and often intense precipitation events. The facility consisted of a series of concrete vaults topped by a multilayer cover. Cover features included a sloping soil surface to promote runoff, plant growth to minimize erosion and promote transportation, a sloping clay layer, and a sloping capillary barrier. The analysis within the root zone was carried out using a one-dimensional, transient simulation of water flow. Below the root zone, the analysis was primarily two-dimensional and steady-state

  6. Safety evaluation of the loss of fluid test facility project No. 394

    International Nuclear Information System (INIS)

    1975-05-01

    Assessment of the safety of the LOFT facility and subsequent recommendations have been based on a comparison of the LOFT facility to requirements for commercial power reactors. In this comparison, the many unique features of the LOFT facility were considered including the low power level, the limited operational use as a test reactor, and the remoteness of the site. Based on this assessment, it is concluded, that while the likelihood of an accidental release of fission products may be greater than for a commercial power reactor, the consequences of such a release are reduced by the lower fission product inventory, the remoteness of the site and the capability of evacuating the Idaho National Engineering Laboratory (INEL) and adjacent areas. There is reasonable assurance that the public health and safety will not be endangered due to operation of this facility, specifically: The INEL site is acceptable with respect to location, land use, population distribution, controlled access, hydrology, meteorology, geology and seismology. Sufficient engineered safety features have been included to assure that the potential offsite doses are well within 10 CFR Part 100 guidelines. The LOFT facility has been designed in general accordance with standards, guides and codes which are comparable to those applied to commercial power reactors and any exceptions to these have been based on the unique features of the LOFT facility. Certain matters including the final safety analyses based on detailed component designs, Technical Specifications, LOCE controls and detailed program plan have not been reviewed but we assume will properly be resolved by ERDA, which has the ultimate responsibility for the safety of this facility. Changes to the facility design or program plan such as removal of the fueled Mobile Test Assembly or blowdowns to the containment vessel also will require additional analyses and review. (U.S.)

  7. Progress towards developing consistent design and evaluation guidelines for US Department of Energy facilities subjected to natural phenomena

    International Nuclear Information System (INIS)

    Murray, R.C.

    1987-01-01

    Probabilistic definitions of earthquake, wind, and tornado hazards for many DOE facilities throughout the United States have been developed. In addition, definitions of the flood hazards which might affect these locations are currently being developed. We have prepared a document to provide guidance and criteria for DOE facility managers to assure that DOE facilities are adequately constructed to resist the effects of natural phenomena such as earthquake, strong wind, and flood. The intent of this document is to provide instruction on how to utilize the hazard definitions to evaluate existing facilities and design new facilities in a manner such that the risk of adverse consequences is consistent with the cost, function, and danger to the public or environment. A conference and six mini-courses were organized on natural phenomena hazards mitigation. This provided a mechanism for technology transfer to the DOE community. Complementary manuals have also been developed for 1) suspended ceiling systems and recommendations for bracing them, 2) practical equipment seismic upgrade and strengthening guidelines, and 3) suggested structural details for wind design. These manuals are intended to provide input and guidance for ongoing site safety programs. (orig./HP)

  8. Evaluating the Effects of Air Pollution from a Plastic Recycling Facility on the Health of Nearby Residents.

    Science.gov (United States)

    Xin, Zhao; Tsuda, Toshihide; Doi, Hiroyuki

    2017-06-01

    We evaluated how exposure to airborne volatile organic compounds emitted from a plastic recycling facility affected nearby residents, in a cross-sectional study. Individuals>10 years old were randomly sampled from 50 households at five sites and given questionnaires to complete. We categorized the subjects by distance from the recycling facility and used this as a proxy measure for pollutant exposure. We sought to improve on a preceding study by generating new findings, improving methods for questionnaire distribution and collection, and refining site selection. We calculated the odds of residents living 500 or 900 m away from the facility reporting mucocutaneous and respiratory symptoms using a reference group of residents 2,800 m away. Self-reported nasal congestion (odds ratio=3.0, 95% confidence interval=1.02-8.8), eczema (5.1, 1.1-22.9), and sore throat (3.9, 1.1-14.1) were significantly higher among residents 500 m from the facility. Those 900 m away were also considerably more likely to report experiencing eczema (4.6, 1.4-14.9). Air pollution was found responsible for significantly increased reports of mucocutaneous and respiratory symptoms among nearby residents. Our findings confirm the effects of pollutants emitted from recycling facilities on residents' health and clarify that study design differences did not affect the results.

  9. Progress towards developing consistent design and evaluation guidelines for US Department of Energy facilities subjected to natural phenomena

    International Nuclear Information System (INIS)

    Murray, R.C.

    1987-01-01

    Probabilistic definitions of earthquake, wind, and tornado hazards for many Department of Energy (DOE) facilities throughout the United States have been developed. In addition, definitions of the flood hazards which might affect these locations are currently being developed. The authors have prepared a document to provide guidance and criteria for DOE facility managers to assure that DOE facilities are adequately constructed to resist the effects of natural phenomena such as earthquake, strong wind, and flood. The intent of this document is to provide instruction on how to utilize the hazard definitions to evaluate existing facilities and design new facilities in a manner such that the risk of adverse consequences is consistent with the cost, function, and danger to the public or environment. A conference and six mini-courses were organized on natural phenomena hazards mitigation. This provided a mechanism for technology transfer to the DOE community. Complementary manuals have also been developed for 1) suspended ceiling systems and recommendations for bracing them, 2) practical equipment seismic upgrade and strengthening guidelines, and 3) suggested structural details for wind design. These manuals are intended to provide input and guidance for ongoing site safety programs

  10. Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211.

    Science.gov (United States)

    Hatt, Mathieu; Lee, John A; Schmidtlein, Charles R; Naqa, Issam El; Caldwell, Curtis; De Bernardi, Elisabetta; Lu, Wei; Das, Shiva; Geets, Xavier; Gregoire, Vincent; Jeraj, Robert; MacManus, Michael P; Mawlawi, Osama R; Nestle, Ursula; Pugachev, Andrei B; Schöder, Heiko; Shepherd, Tony; Spezi, Emiliano; Visvikis, Dimitris; Zaidi, Habib; Kirov, Assen S

    2017-06-01

    The purpose of this educational report is to provide an overview of the present state-of-the-art PET auto-segmentation (PET-AS) algorithms and their respective validation, with an emphasis on providing the user with help in understanding the challenges and pitfalls associated with selecting and implementing a PET-AS algorithm for a particular application. A brief description of the different types of PET-AS algorithms is provided using a classification based on method complexity and type. The advantages and the limitations of the current PET-AS algorithms are highlighted based on current publications and existing comparison studies. A review of the available image datasets and contour evaluation metrics in terms of their applicability for establishing a standardized evaluation of PET-AS algorithms is provided. The performance requirements for the algorithms and their dependence on the application, the radiotracer used and the evaluation criteria are described and discussed. Finally, a procedure for algorithm acceptance and implementation, as well as the complementary role of manual and auto-segmentation are addressed. A large number of PET-AS algorithms have been developed within the last 20 years. Many of the proposed algorithms are based on either fixed or adaptively selected thresholds. More recently, numerous papers have proposed the use of more advanced image analysis paradigms to perform semi-automated delineation of the PET images. However, the level of algorithm validation is variable and for most published algorithms is either insufficient or inconsistent which prevents recommending a single algorithm. This is compounded by the fact that realistic image configurations with low signal-to-noise ratios (SNR) and heterogeneous tracer distributions have rarely been used. Large variations in the evaluation methods used in the literature point to the need for a standardized evaluation protocol. Available comparison studies suggest that PET-AS algorithms relying

  11. Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211

    Science.gov (United States)

    Hatt, Mathieu; Lee, John A.; Schmidtlein, Charles R.; Naqa, Issam El; Caldwell, Curtis; De Bernardi, Elisabetta; Lu, Wei; Das, Shiva; Geets, Xavier; Gregoire, Vincent; Jeraj, Robert; MacManus, Michael P.; Mawlawi, Osama R.; Nestle, Ursula; Pugachev, Andrei B.; Schöder, Heiko; Shepherd, Tony; Spezi, Emiliano; Visvikis, Dimitris; Zaidi, Habib; Kirov, Assen S.

    2017-01-01

    Purpose The purpose of this educational report is to provide an overview of the present state-of-the-art PET auto-segmentation (PET-AS) algorithms and their respective validation, with an emphasis on providing the user with help in understanding the challenges and pitfalls associated with selecting and implementing a PET-AS algorithm for a particular application. Approach A brief description of the different types of PET-AS algorithms is provided using a classification based on method complexity and type. The advantages and the limitations of the current PET-AS algorithms are highlighted based on current publications and existing comparison studies. A review of the available image datasets and contour evaluation metrics in terms of their applicability for establishing a standardized evaluation of PET-AS algorithms is provided. The performance requirements for the algorithms and their dependence on the application, the radiotracer used and the evaluation criteria are described and discussed. Finally, a procedure for algorithm acceptance and implementation, as well as the complementary role of manual and auto-segmentation are addressed. Findings A large number of PET-AS algorithms have been developed within the last 20 years. Many of the proposed algorithms are based on either fixed or adaptively selected thresholds. More recently, numerous papers have proposed the use of more advanced image analysis paradigms to perform semi-automated delineation of the PET images. However, the level of algorithm validation is variable and for most published algorithms is either insufficient or inconsistent which prevents recommending a single algorithm. This is compounded by the fact that realistic image configurations with low signal-to-noise ratios (SNR) and heterogeneous tracer distributions have rarely been used. Large variations in the evaluation methods used in the literature point to the need for a standardized evaluation protocol. Conclusions Available comparison studies

  12. DOE LLW classification rationale

    International Nuclear Information System (INIS)

    Flores, A.Y.

    1991-01-01

    This report was about the rationale which the US Department of Energy had with low-level radioactive waste (LLW) classification. It is based on the Nuclear Regulatory Commission's classification system. DOE site operators met to review the qualifications and characteristics of the classification systems. They evaluated performance objectives, developed waste classification tables, and compiled dose limits on the waste. A goal of the LLW classification system was to allow each disposal site the freedom to develop limits to radionuclide inventories and concentrations according to its own site-specific characteristics. This goal was achieved with the adoption of a performance objectives system based on a performance assessment, with site-specific environmental conditions and engineered disposal systems

  13. Engineering Evaluation/Cost Analysis for Power Burst Facility (PER-620) Final End State and PBF Vessel Disposal

    Energy Technology Data Exchange (ETDEWEB)

    B. C. Culp

    2007-05-01

    Preparation of this engineering evaluation/cost analysis is consistent with the joint U.S. Department of Energy and U.S. Environmental Protection Agency Policy on Decommissioning of Department of Energy Facilities Under the Comprehensive Environmental Response, Compensation, and Liability Act, (DOE and EPA 1995) which establishes the Comprehensive Environmental, Response, Compensation, and Liability Act non-time critical removal action process as an approach for decommissioning. The scope of this engineering evaluation/cost analysis is to evaluate alternatives and recommend a preferred alternative for the final end state of the PBF and the final disposal location for the PBF vessel.

  14. EVALUATION OF MERCURY EMISSIONS FROM COAL-FIRED FACILITIES WITH SCR AND FGD SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    J.A. Withum; S.C. Tseng; J.E. Locke

    2005-11-01

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dryer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the seventh in a series of topical reports, describes the results and analysis of mercury sampling performed on a 1,300 MW unit burning a bituminous coal containing three percent sulfur. The unit was equipped with an ESP and a limestone-based wet FGD to control particulate and SO2 emissions, respectively. At the time of sampling an SCR was not installed on this unit. Four sampling tests were performed in September 2003. Flue gas mercury speciation and concentrations were determined at the ESP outlet (FGD inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Process stream samples for a mercury balance were collected to coincide with the flue gas measurements. The results show that the FGD inlet flue gas oxidized:elemental mercury ratio was roughly 2:1, with 66% oxidized mercury and 34% elemental mercury. Mercury removal, on a coal

  15. Evaluation of Mercury Emissions from Coal-Fired Facilities with SCR and FGD Systems

    Energy Technology Data Exchange (ETDEWEB)

    J. A. Withum; S. C. Tseng; J. E. Locke

    2006-01-31

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The principal purpose of this work is to develop a better understanding of the potential mercury removal ''co-benefits'' achieved by NO{sub x}, and SO{sub 2} control technologies. It is expected that these data will provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize mercury removal. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of SCR catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the ninth in a series of topical reports, describes the results and analysis of mercury sampling performed on Unit 1 at Plant 7, a 566 MW unit burning a bituminous coal containing 3.6% sulfur. The unit is equipped with a SCR, ESP, and wet FGD to control NO{sub x}, particulate, and SO

  16. Evaluation of Mercury Emissions from Coal-Fired Facilities with SCR and FGD Systems

    Energy Technology Data Exchange (ETDEWEB)

    J. A. Withum; J. E. Locke

    2006-02-01

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The principal purpose of this work is to develop a better understanding of the potential mercury removal ''co-benefits'' achieved by NO{sub x}, and SO{sub 2} control technologies. It is expected that this data will provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize mercury removal. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of SCR catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the tenth in a series of topical reports, describes the results and analysis of mercury sampling performed on two 468 MW units burning bituminous coal containing 1.3-1.7% sulfur. Unit 2 is equipped with an SCR, ESP, and wet FGD to control NO{sub x}, particulate, and SO{sub 2} emissions

  17. EVALUATION OF MERCURY EMISSIONS FROM COAL-FIRED FACILITIES WITH SCR AND FGD SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    J. A. Withum; S.C. Tseng; J. E. Locke

    2004-10-31

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on Hg speciation and the efficacy of different FGD technologies for Hg capture. This document, the second in a series of topical reports, describes the results and analysis of mercury sampling performed on a 330 MW unit burning a bituminous coal containing 1.0% sulfur. The unit is equipped with a SCR system for NOx control and a spray dryer absorber for SO{sub 2} control followed by a baghouse unit for particulate emissions control. Four sampling tests were performed in March 2003. Flue gas mercury speciation and concentrations were determined at the SCR inlet, air heater outlet (ESP inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Process stream samples for a mercury balance were collected to coincide with the flue gas measurements. Due to mechanical problems with the boiler feed water pumps, the actual gross output was between 195 and 221 MW during the tests. The results showed that the SCR/air heater combination oxidized nearly 95% of the elemental mercury. Mercury removal, on a

  18. Optimal design of modular cogeneration plants for hospital facilities and robustness evaluation of the results

    International Nuclear Information System (INIS)

    Gimelli, A.; Muccillo, M.; Sannino, R.

    2017-01-01

    Highlights: • A specific methodology has been set up based on genetic optimization algorithm. • Results highlight a tradeoff between primary energy savings (TPES) and simple payback (SPB). • Optimized plant configurations show TPES exceeding 18% and SPB of approximately three years. • The study aims to identify the most stable plant solutions through the robust design optimization. • The research shows how a deterministic definition of the decision variables could lead to an overestimation of the results. - Abstract: The widespread adoption of combined heat and power generation is widely recognized as a strategic goal to achieve significant primary energy savings and lower carbon dioxide emissions. In this context, the purpose of this research is to evaluate the potential of cogeneration based on reciprocating gas engines for some Italian hospital buildings. Comparative analyses have been conducted based on the load profiles of two specific hospital facilities and through the study of the cogeneration system-user interaction. To this end, a specific methodology has been set up by coupling a specifically developed calculation algorithm to a genetic optimization algorithm, and a multi-objective approach has been adopted. The results from the optimization problem highlight a clear trade-off between total primary energy savings (TPES) and simple payback period (SPB). Optimized plant configurations and management strategies show TPES exceeding 18% for the reference hospital facilities and multi–gas engine solutions along with a minimum SPB of approximately three years, thereby justifying the European regulation promoting cogeneration. However, designing a CHP plant for a specific energetic, legislative or market scenario does not guarantee good performance when these scenarios change. For this reason, the proposed methodology has been enhanced in order to focus on some innovative aspects. In particular, this study proposes an uncommon and effective approach

  19. The Upgrade Programme for the Structural Biology beamlines at the European Synchrotron Radiation Facility - High throughput sample evaluation and automation

    Science.gov (United States)

    Theveneau, P.; Baker, R.; Barrett, R.; Beteva, A.; Bowler, M. W.; Carpentier, P.; Caserotto, H.; de Sanctis, D.; Dobias, F.; Flot, D.; Guijarro, M.; Giraud, T.; Lentini, M.; Leonard, G. A.; Mattenet, M.; McCarthy, A. A.; McSweeney, S. M.; Morawe, C.; Nanao, M.; Nurizzo, D.; Ohlsson, S.; Pernot, P.; Popov, A. N.; Round, A.; Royant, A.; Schmid, W.; Snigirev, A.; Surr, J.; Mueller-Dieckmann, C.

    2013-03-01

    Automation and advances in technology are the key elements in addressing the steadily increasing complexity of Macromolecular Crystallography (MX) experiments. Much of this complexity is due to the inter-and intra-crystal heterogeneity in diffraction quality often observed for crystals of multi-component macromolecular assemblies or membrane proteins. Such heterogeneity makes high-throughput sample evaluation an important and necessary tool for increasing the chances of a successful structure determination. The introduction at the ESRF of automatic sample changers in 2005 dramatically increased the number of samples that were tested for diffraction quality. This "first generation" of automation, coupled with advances in software aimed at optimising data collection strategies in MX, resulted in a three-fold increase in the number of crystal structures elucidated per year using data collected at the ESRF. In addition, sample evaluation can be further complemented using small angle scattering experiments on the newly constructed bioSAXS facility on BM29 and the micro-spectroscopy facility (ID29S). The construction of a second generation of automated facilities on the MASSIF (Massively Automated Sample Screening Integrated Facility) beam lines will build on these advances and should provide a paradigm shift in how MX experiments are carried out which will benefit the entire Structural Biology community.

  20. Grande Ronde Endemic Spring Chinook Salmon Supplementation Program: Facility Operation and Maintenance and Monitoring and Evaluation, 2000 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Boe, Stephen J.; Lofy, Peter T. (Confederated Tribes of the Umatilla Indian Reservation, Pendleton, OR)

    2003-03-01

    This is the third annual report of a multi-year project to operate adult collection and juvenile acclimation facilities on Catherine Creek and the upper Grande Ronde River for Snake River spring chinook salmon. These two streams have historically supported populations that provided significant tribal and non-tribal fisheries. Supplementation using conventional and captive broodstock techniques is being used to restore fisheries in these streams. Statement of Work Objectives for 2000: (1) Participate in implementation of the comprehensive multiyear operations plan for the Grande Ronde Endemic Spring Chinook Supplementation Program (GRESCP). (2) Plan for recovery of endemic summer steelhead populations in Catherine Creek and the upper Grande Ronde River. (3) Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2000. (4) Collect summer steelhead. (5) Collect adult endemic spring chinook salmon broodstock. (6) Acclimate juvenile spring chinook salmon prior to release into the upper Grande Ronde River and Catherine Creek. (7) Document accomplishments and needs to permitters, comanagers, and funding agency. (8) Communicate project results to the scientific community. (9) Plan detailed GRESCP Monitoring and Evaluation for future years. (10) Monitor adult population abundance and characteristics of Grande Ronde River spring chinook salmon populations and incidentally-caught summer steelhead and bull trout. (11) Monitor condition, movement, and mortality of spring chinook salmon acclimated at remote facilities. (12) Monitor water quality at facilities. (13) Participate in Monitoring & Evaluation of the captive brood component of the Program to document contribution to the Program.

  1. [Design of a supervision model for administration of the Child Development Evaluation Test at primary care facilities in Mexico].

    Science.gov (United States)

    Villasís-Keever, Miguel Ángel; Rizzoli-Córdoba, Antonio; Delgado-Ginebra, Ismael; Mares-Serratos, Blanca Berenice; Martell-Valdez, Liliana; Sánchez-Velázquez, Olivia; Reyes-Morales, Hortensia; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Antillón-Ocampo, Fátima Adriana; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Baqueiro-Hernández, César Iván; Pizarro-Castellanos, Mariel; Martain-Pérez, Itzamara Jacqueline; Palma-Tavera, Josuha Alexander; Vargas-López, Guillermo; Muñoz-Hernández, Onofre

    The Child Development Evaluation (CDE) test designed and validated in Mexico has been used as a screening tool for developmental problems in primary care facilities across Mexico. Heterogeneous results were found among those states where these were applied, despite using the same standardized training model for application. The objective was to evaluate a supervision model for quality of application of the CDE test at primary care facilities. A study was carried out in primary care facilities from three Mexican states to evaluate concordance of the results between supervisor and primary care personnel who administered the test using two different methods: direct observation (shadow study) or reapplication of the CDE test (consistency study). There were 380 shadow studies applied to 51 psychologists. General concordance of the shadow study was 86.1% according to the supervisor: green 94.5%, yellow 73.2% and red 80.0%. There were 302 re-test evaluations with a concordance of 88.1% (n=266): green 96.8%, yellow 71.7% and red 81.8%. There were no differences between CDE test subgroups by age. Both shadow and re-test study were adequate for the evaluation of the quality of the administration of the CDE Test and may be useful as a model of supervision in primary care facilities. The decision of which test to use relies on the availability of supervisors. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  2. Optimization of reproductive management programs using lift chart analysis and cost-sensitive evaluation of classification errors.

    Science.gov (United States)

    Shahinfar, Saleh; Guenther, Jerry N; Page, C David; Kalantari, Afshin S; Cabrera, Victor E; Fricke, Paul M; Weigel, Kent A

    2015-06-01

    yield relative to contemporaries. In the second data set, the strategy of inseminating only a subset consisting of 59% of the most fertile cows conferred a gain in profit of $5.21 per eligible cow in a monthly breeding period. These results suggest that, when used with a powerful classification algorithm, lift chart analysis and cost-sensitive evaluation of correctly classified and misclassified insemination events can enhance the performance and profitability of reproductive management programs on commercial dairy farms. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. DARA Solid Storage Facility evaluation and recommendations, Y-12 Bear Creek Burial Grounds, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Barton, W.D. III; Hughey, J.C.

    1992-08-01

    The Disposal Area Remedial Action (DARA) Solid Storage Facility (SSF) is a rectangular concrete vault with two high-density Polyethlene (HDPE) liners and covered with a metal building. The SSF was originally designed and constructed to receive saturated sediments from the excavation of the Oil Retention Ponds and Tributary 7 at the Oak Ridge Y-12 Plant. The sediments placed in the SSF were generally high-water-content soils contaminated with polychlorinated biphenyls (PCBs) and volatile organic carbons. The facility was intended to dewater the sediments by allowing the free water to percolate to a 6-in. sand layer covering the entire floor of the facility. The sand layer then drained into sumps located at the east and west ends of the facility. An application for a Part-B Permit was submitted to the state of Tennessee in February 1992 (MMES 1992a). This report is being submitted to support approval of that permit application and to address certain issues known to the regulators regarding this facility

  4. Evaluation Of A Turbidity Meter For Use At The Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Mahannah, R. N.; Edwards, T. B.

    2013-01-01

    Savannah River Remediation's (SRR's) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a ''peanut'' vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 wt%. A ''go/no-go'' decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a ''go'' decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a ''no-go'' determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. A sludge simulant was used to develop standards

  5. Evaluation of a turbidity meter for use at the Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Mahannah, R.N; Edwards, T.B.

    2013-01-01

    Savannah River RemediationÆs (SRRÆs) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a ôpeanutö vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A ''go/no-go'' decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a ''go'' decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a ''no-go'' determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the issuance of

  6. Evaluation Of A Turbidity Meter For Use At The Defense Waste Processing Facility

    Energy Technology Data Exchange (ETDEWEB)

    Mahannah, R. N.; Edwards, T. B.

    2013-01-15

    Savannah River Remediation's (SRR's) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a ''peanut'' vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 wt%. A ''go/no-go'' decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a ''go'' decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a ''no-go'' determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. A sludge simulant was used to develop standards

  7. EVALUATION OF A TURBIDITY METER FOR USE AT THE DEFENSE WASTE PROCESSING FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Mahannah, R.; Edwards, T.

    2013-06-04

    Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A “go/no-go” decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a “go” decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a “no-go” determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the

  8. Performance Evaluation of Downscaling Sentinel-2 Imagery for Land Use and Land Cover Classification by Spectral-Spatial Features

    Directory of Open Access Journals (Sweden)

    Hongrui Zheng

    2017-12-01

    Full Text Available Land Use and Land Cover (LULC classification is vital for environmental and ecological applications. Sentinel-2 is a new generation land monitoring satellite with the advantages of novel spectral capabilities, wide coverage and fine spatial and temporal resolutions. The effects of different spatial resolution unification schemes and methods on LULC classification have been scarcely investigated for Sentinel-2. This paper bridged this gap by comparing the differences between upscaling and downscaling as well as different downscaling algorithms from the point of view of LULC classification accuracy. The studied downscaling algorithms include nearest neighbor resampling and five popular pansharpening methods, namely, Gram-Schmidt (GS, nearest neighbor diffusion (NNDiffusion, PANSHARP algorithm proposed by Y. Zhang, wavelet transformation fusion (WTF and high-pass filter fusion (HPF. Two spatial features, textural metrics derived from Grey-Level-Co-occurrence Matrix (GLCM and extended attribute profiles (EAPs, are investigated to make up for the shortcoming of pixel-based spectral classification. Random forest (RF is adopted as the classifier. The experiment was conducted in Xitiaoxi watershed, China. The results demonstrated that downscaling obviously outperforms upscaling in terms of classification accuracy. For downscaling, image sharpening has no obvious advantages than spatial interpolation. Different image sharpening algorithms have distinct effects. Two multiresolution analysis (MRA-based methods, i.e., WTF and HFP, achieve the best performance. GS achieved a similar accuracy with NNDiffusion and PANSHARP. Compared to image sharpening, the introduction of spatial features, both GLCM and EAPs can greatly improve the classification accuracy for Sentinel-2 imagery. Their effects on overall accuracy are similar but differ significantly to specific classes. In general, using the spectral bands downscaled by nearest neighbor interpolation can meet

  9. Transforming landscape ecological evaluations using sub-pixel remote sensing classifications: A study of invasive saltcedar (Tamarix spp.)

    Science.gov (United States)

    Frazier, Amy E.

    Invasive species disrupt landscape patterns and compromise the functionality of ecosystem processes. Non-native saltcedar (Tamarix spp.) poses significant threats to native vegetation and groundwater resources in the southwestern U.S. and Mexico, and quantifying spatial and temporal distribution patterns is essential for monitoring its spread. Advanced remote sensing classification techniques such as sub-pixel classifications are able to detect and discriminate saltcedar from native vegetation with high accuracy, but these types of classifications are not compatible with landscape metrics, which are the primary tool available for statistically assessing distribution patterns, because they do not have discrete class boundaries. The objective of this research is to develop new methods that allow sub-pixel classifications to be analyzed using landscape metrics. The research will be carried out through three specific aims: (1) develop and test a method to transform continuous sub-pixel classifications into categorical representations that are compatible with widely used landscape metric tools, (2) establish a gradient-based concept of landscape using sub-pixel classifications and the technique developed in the first objective to explore the relationships between pattern and process, and (3) generate a new super-resolution mapping technique method to predict the spatial locations of fractional land covers within a pixel. Results show that the threshold gradient method is appropriate for discretizing sub-pixel data, and can be used to generate increased information about the landscape compared to traditional single-value metrics. Additionally, the super-resolution classification technique was also able to provide detailed sub-pixel mapping information, but additional work will be needed to develop rigorous validation and accuracy assessment techniques.

  10. Radiation dose evaluation based on exposure scenario during the operation of radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Yoon, Jeong Hyoun; Kim Chang Lak; Choi, Heui Joo; Park, Joo Wan

    1999-01-01

    Radiation dose to worker in disposal facility was calculated by using point kernel MICROSHIELD V5.02 computer code based on exposure scenarios. An conceptual design model for disposal vaults in disposal facility was used for object of shielding calculation model. Selected radionuclides and their activities among radioactive wastes from nuclear power plants were assumed as radiation sources for the exposure calculation. Annual radiation doses to crane workers and to people working on disposal vaults were calculated according to exposure time and distance from the sources with conservative operation scenarios. The scenarios used for this study were based on assumption for representing disposal activities in a future Korean near surface disposal facility. Calculated exposure rates to worker during normal disposal work were very low comparing with annual allowable limit for radiation worker

  11. Evaluation of the long duration efficiency of the ECC storage facility of Cogema La Hague plant

    International Nuclear Information System (INIS)

    Baganz, C.; Bouland, P.; Breton, E.

    2004-01-01

    The ECC facility of Cogema La Hague has been designed in view of the storage of 24000 CSD-C type containers produced by the ACC facility. It comprises a reception and unloading unit, and a modular storage unit (alveoles). The safety of the facility is based on: a controlled ventilation (low pressurization rooms, controlled atmosphere, heat and toxic gases evacuation), a construction ensuring the static confinement, the sub-criticality and the radiological protection, and the possibility of natural ventilation of the alveoles (earthquake-dimensioned equipments). On the basis of these safety functions, the conformability of the facility with respect to long duration has been analyzed considering three aspects of the facility: the infrastructure, the waste packages and the ventilation system. In normal operation, a foreseeable service life of at least 100 years is established: simpleness and accessibility of ventilation systems, no significant corrosion of packages, durability of the reinforced concrete structure. The demonstration of a service life greater than 100 years would require the improvement of our knowledge about concretes in terms of experience feedback. The behaviour of the facility in terms of loss of technical mastery has been considered too. The scenario retained for this situation is the prolonged stoppage (several months or years) of the nuclear ventilation after a 100 years of disposal. After this period of time, both the thermal power and the hydrogen generation from waste packages will have significantly diminished, allowing a loss of technical mastery era of several years with no impact on concretes integrity. However, during long situations of non-controlled atmosphere, the corrosion behaviour of stainless steels is not predictable. (J.S.)

  12. Applicability of the International Classification of Functioning, Disability and Health (ICF for evaluation of children with cerebral palsy: a systematic review

    Directory of Open Access Journals (Sweden)

    Lílian de Fátima Dornelas

    2014-12-01

    Full Text Available Objective: To examine and synthesize the knowledge available in the literature on the instruments used in the perspective of functionality in children with cerebral palsy (CP, and to review the literature evaluating the instruments used for the implementation of the International Classification of Functioning, Disability and Health (ICF in children with CP. Method: The search was conducted in the electronic databases Google Scholar, PubMed, Lilacs and Medline, for articles published between January 2006 and December 2012, using the following keywords: cerebral palsy, child and assessment, combined with ICF. Ten articles were selected for analysis according to pre-established criteria. Results: The authors proposed tools that could standardize the assessment for classification of the components “Structure and function of the body”, “Activities and Participation” and “Environmental Factors”, proposing instruments such as Gross Motor Function Measure (GMFM, Pediatric Evaluation of Disability Inventory (PEDI, Goal Attainment Scaling (GAS, Manual Ability Classification System (MACS, Gross Motor Function Classification System (GMFCS, Physicians Rating Scale (PRS, Vineland Adaptive Behavior Scale (VABS, Pediatric Functional Independence Measure (Wee FIM, Gillette Functional Assessment Questionnaire (FAQ, Pediatric Quality of Life Inventory (PedsQL, Pediatric Outcomes Data Collection Instrument (PODCI, Gillette Gait Index (GGI, Energy Expenditure Index (EEI, and Vécu et Santé Perçue de l’Adolescent (VSP-A. Conclusion: The domains “Structure and function of the body” and “Activities and Participation” are often classified according to ICF in children with CP, and they present a variety of instrumentation for applicability of classification.

  13. Evaluation of pelletron accelerator facility to study radiation effects on semiconductor devices

    International Nuclear Information System (INIS)

    Prakash, A. P. Gnana; Pushpa, N.; Praveen, K. C.; Naik, P. S.; Revannasiddaiah, D.

    2012-01-01

    In this paper we present the comprehensive results on the effects of different radiation on the electrical characteristics of different semiconductor devices like Si BJT, n-channel MOSFETs, 50 GHz and 200 GHz silicon-germanium heterojunction bipolar transistor (SiGe HBTs). The total dose effects of different radiation are compared in the same total dose ranging from 100 krad to 100 Mrad. We show that the irradiation time needed to reach very high total dose can be reduced by using Pelletron accelerator facilities instead of conventional irradiation facilities.

  14. Thermodynamic Evaluation of Floating Production Storage and Offloading Facilities with Liquefaction Processes

    DEFF Research Database (Denmark)

    Nguyen, Tuong-Van; Sánchez, Yamid Alberto Carranza; Junior, Silvio de Oliveira

    2016-01-01

    Floating, production, storage and offloading (FPSO) plants are facilities used in upstream petroleum processing.They have gained interest because they are more flexible than conventional plants and can be used for producingoil and gas in deep-water fields. In general, gas export is challenging...... because of the lack of infrastructure in remotelocations. The present work investigates the possibility of integrating liquefaction processes on such facilities, consideringfour possible petroleum compositions, which differ in their contents of carbon dioxide, light and heavy hydrocarbons.The performance...

  15. Evaluation of pelletron accelerator facility to study radiation effects on semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, A. P. Gnana; Pushpa, N.; Praveen, K. C.; Naik, P. S.; Revannasiddaiah, D. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore-570006, Karnataka (India)

    2012-06-05

    In this paper we present the comprehensive results on the effects of different radiation on the electrical characteristics of different semiconductor devices like Si BJT, n-channel MOSFETs, 50 GHz and 200 GHz silicon-germanium heterojunction bipolar transistor (SiGe HBTs). The total dose effects of different radiation are compared in the same total dose ranging from 100 krad to 100 Mrad. We show that the irradiation time needed to reach very high total dose can be reduced by using Pelletron accelerator facilities instead of conventional irradiation facilities.

  16. A comprehensive quality evaluation method by FT-NIR spectroscopy and chemometric: Fine classification and untargeted authentication against multiple frauds for Chinese Ganoderma lucidum

    Science.gov (United States)

    Fu, Haiyan; Yin, Qiaobo; Xu, Lu; Wang, Weizheng; Chen, Feng; Yang, Tianming

    2017-07-01

    The origins and authenticity against frauds are two essential aspects of food quality. In this work, a comprehensive quality evaluation method by FT-NIR spectroscopy and chemometrics were suggested to address the geographical origins and authentication of Chinese Ganoderma lucidum (GL). Classification for 25 groups of GL samples (7 common species from 15 producing areas) was performed using near-infrared spectroscopy and interval-combination One-Versus-One least squares support vector machine (IC-OVO-LS-SVM). Untargeted analysis of 4 adulterants of cheaper mushrooms was performed by one-class partial least squares (OCPLS) modeling for each of the 7 GL species. After outlier diagnosis and comparing the influences of different preprocessing methods and spectral intervals on classification, IC-OVO-LS-SVM with standard normal variate (SNV) spectra obtained a total classification accuracy of 0.9317, an average sensitivity and specificity of 0.9306 and 0.9971, respectively. With SNV or second-order derivative (D2) spectra, OCPLS could detect at least 2% or more doping levels of adulterants for 5 of the 7 GL species and 5% or more doping levels for the other 2 GL species. This study demonstrates the feasibility of using new chemometrics and NIR spectroscopy for fine classification of GL geographical origins and species as well as for untargeted analysis of multiple adulterants.

  17. Diagnosing multibacillary leprosy: A comparative evaluation of diagnostic accuracy of slit-skin smear, bacterial index of granuloma and WHO operational classification

    Directory of Open Access Journals (Sweden)

    Bhushan Premanshu

    2008-01-01

    Full Text Available Background: In view of the relatively poor performance of skin smears WHO adopted a purely clinical operational classification, however the poor specificity of operational classification leads to overdiagnosis and unwarranted overtreatment while the poor sensitivity leads to underdiagnosis of multibacillary (MB cases with inadequate treatment. Bacilli are more frequently and abundantly demonstrated in tissue sections. Aims and Methods: We compared WHO classification, slit-skin smears (SSS and demonstration of bacilli in biopsies (bacterial index of granuloma or BIG with regards to their efficacy in correctly identifying multibacillary cases. The tests were done on 141 patients and were evaluated for their ability to diagnose true MB leprosy using detailed statistical analysis. Results: A total of 76 patients were truly MB with either positive smears, BIG positivity or with a typical histology of BB, BL or LL. Amongst these 76 true-MB patients, WHO operational classification correctly identified multibacillary status in 56 (73.68%, and SSS in 43 (56.58%, while BIG correctly identified 65 (85.53% true-MB cases. Conclusion: BIG was most sensitive and effective of the three methods especially in paucilesional patients. We suggest adding estimation of bacterial index of granuloma in the diagnostic workup of paucilesional patients.

  18. Best Practices for Controlling Tuberculosis-Training in Correctional Facilities: A Mixed Methods Evaluation

    Science.gov (United States)

    Murray, Ellen R.

    2016-01-01

    According to the literature, identifying and treating tuberculosis (TB) in correctional facilities have been problematic for the inmates and also for the communities into which inmates are released. The importance of training those who can identify this disease early into incarceration is vital to halt the transmission. Although some training has…

  19. Beam Test for Evaluating Applicabillity of High - Strength Reinforcement in Structure of Nuclear Facility

    International Nuclear Information System (INIS)

    Yim, Sangjun; Lee, Byungsoo; Bang, Changjoon

    2014-01-01

    The high-strength rebar which has high yield strength can reduce the amount of rebar in concrete and widen its spacing so that it has better workability and higher economic benefits for the structure. However, the maximum yield strength of rebar is limited to 420MPa in the design criteria for structure of nuclear facility in Korea and USA. Korea Hydro and Nuclear Power is progressing research to revise the limitation in the yield strength of rebar, which is suggested in the criteria of KEPIC and ACI, in order to apply 550 MPa high-strength rebar for the construction of a nuclear facility. This study is to review the applicability of high strength rebar in structure of a nuclear facility through a model beam test. After reviewing the shear capacity and reinforcement yield to assess the applicability of high-strength reinforcement in the structure of a nuclear facility, we make the following conclusions. When using high shear reinforcement with wider spacing, it has a similar shear capacity to normal reinforcement with narrower spacing. This means better workability and economic benefits can be achieved by widening the rebar spacing without brittle fracture in the elements. For future plans, the results of this test and supplementary test will be submitted to ACI349 committee as backup data to revise the standard for yield strength of high-strength rebar

  20. Beam Test for Evaluating Applicabillity of High - Strength Reinforcement in Structure of Nuclear Facility

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Sangjun; Lee, Byungsoo; Bang, Changjoon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    The high-strength rebar which has high yield strength can reduce the amount of rebar in concrete and widen its spacing so that it has better workability and higher economic benefits for the structure. However, the maximum yield strength of rebar is limited to 420MPa in the design criteria for structure of nuclear facility in Korea and USA. Korea Hydro and Nuclear Power is progressing research to revise the limitation in the yield strength of rebar, which is suggested in the criteria of KEPIC and ACI, in order to apply 550 MPa high-strength rebar for the construction of a nuclear facility. This study is to review the applicability of high strength rebar in structure of a nuclear facility through a model beam test. After reviewing the shear capacity and reinforcement yield to assess the applicability of high-strength reinforcement in the structure of a nuclear facility, we make the following conclusions. When using high shear reinforcement with wider spacing, it has a similar shear capacity to normal reinforcement with narrower spacing. This means better workability and economic benefits can be achieved by widening the rebar spacing without brittle fracture in the elements. For future plans, the results of this test and supplementary test will be submitted to ACI349 committee as backup data to revise the standard for yield strength of high-strength rebar.