  1. Risk effectiveness evaluation of surveillance testing

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    To address the concerns about nuclear power plant surveillance tests, i.e., their adverse safety impact due to negative effects and too burdensome requirements, it is necessary to evaluate the safety significance or risk effectiveness of such tests explicitly considering both negative and positive effects. This paper defines the negative effects of surveillance testing from a risk perspective, and then presents a methodology to quantify the negative risk impact, i.e., the risk penalty or risk increase caused by the test. The method focuses on two important kinds of negative effects, namely, test-caused transients and test-caused equipment degradations. The concepts and quantitative methods for the risk evaluation can be used in the decision-making process to establish the safety significance of the tests and to screen the plant-specific surveillance test requirements. 6 refs., 2 figs., 2 tabs

  2. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  3. Establishment, test and evaluation of a prototype volcano surveillance system

    Science.gov (United States)

    Ward, P. L.; Eaton, J. P.; Endo, E.; Harlow, D.; Marquez, D.; Allen, R.

    1973-01-01

    A volcano-surveillance system utilizing 23 multilevel earthquake counters and 6 biaxial borehole tiltmeters is being installed and tested on 15 volcanoes in 4 States and 4 foreign countries. The purpose of this system is to give early warning when apparently dormant volcanoes are becoming active. The data are relayed through the ERTS-Data Collection System to Menlo Park for analysis. Installation was completed in 1972 on the volcanoes St. Augustine and Iliamna in Alaska, Kilauea in Hawaii, Baker, Rainier and St. Helens in Washington, Lassen in California, and at a site near Reykjavik, Iceland. Installation continues and should be completed in April 1973 on the volcanoes Santiaguito, Fuego, Agua and Pacaya in Guatemala, Izalco in El Salvador and San Cristobal, Telica and Cerro Negro in Nicaragua.

  4. Surveillance test interval optimization

    International Nuclear Information System (INIS)

    Cepin, M.; Mavko, B.

    1995-01-01

    Technical specifications have been developed on the bases of deterministic analyses, engineering judgment, and expert opinion. This paper introduces our risk-based approach to surveillance test interval (STI) optimization. This approach consists of three main levels. The first level is the component level, which serves as a rough estimation of the optimal STI and can be calculated analytically by a differentiating equation for mean unavailability. The second and third levels give more representative results. They take into account the results of probabilistic risk assessment (PRA) calculated by a personal computer (PC) based code and are based on system unavailability at the system level and on core damage frequency at the plant level

  5. Evaluation of HFIR vessel surveillance data and hydro-test conditions

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Nanstad, R.K.

    1994-01-01

    Surveillance specimens for the High Flux Isotope Reactor (HFIR) pressure vessel were removed and tested during 1993, after the vessel had accumulated 701,469 MWd of operation. The data agree well with HFIR surveillance data obtained in previous years. In conjunction with this effort, the vessel hydro-test conditions were reevaluated and found to be more than adequate. In view of this result, and because there are economic incentives for reducing the frequency of hydro testing, an analysis was performed to determine the minimum permissible frequency. The value obtained is substantially less than that presently specified. It was also determined that a somewhat lower cooling-tower-basin temperature is acceptable (improves operational flexibility). In 1986, after ∼20 years of reactor operation, it was discovered that the vessel embrittlement rate was substantially greater than expected. Possible reasons for the accelerated rate are reviewed in this report

  6. Evaluation of surveillance case definition in the diagnosis of leptospirosis, using the Microscopic Agglutination Test: a validation study.

    Science.gov (United States)

    Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L

    2009-04-22

    Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.

  7. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    2014-09-01

    Full Text Available Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA setting.

  8. Risk-based evaluation of allowed outage time and surveillance test interval extensions for nuclear power plants

    International Nuclear Information System (INIS)

    Gibelli, Sonia Maria Orlando

    2008-03-01

    The main goal of this work is, through the use of Probabilistic Safety Analysis (PSA), to evaluate Technical Specification (TS) Allowed Outage Times (AOT) and Surveillance Test Intervals (STI) extensions for Angra 1 nuclear power plant. PSA has been incorporated as an additional tool, required as part of NPP licensing process. The risk measure used in this work is the Core Damage Frequency (CDF), obtained from the Angra 1 PSA Level 1. AOT and STI extensions are calculated for the Safety Injection System (SIS), Service water System (SAS) and Auxiliary Feedwater System (AFS) through the use of SAPHIRE code. In order to compensate for the risk increase caused by the extensions, compensatory measures as test of redundant train prior to entering maintenance and staggered test strategy are proposed. Results have shown that the proposed AOT extensions are acceptable for the SIS and SAS with the implementation of compensatory measures. The proposed AOT extension is not acceptable for the AFS. The STI extensions are acceptable for all three systems. (author)

  9. JOINT INTELLIGENCE, SURVEILLANCE, & RECONNAISSANCE (ISR) TEST & EVALUATION (JISR-TE) FACILITY

    Data.gov (United States)

    Federal Laboratory Consortium — To meet the needs of the Warfighter, the JISR-TE facility provides the US, NATO, and Coalition members standards conformance testing of imagery capabilities across...

  10. Field Evaluation of a Coproantigen Detection Test for Fascioliasis Diagnosis and Surveillance in Human Hyperendemic Areas of Andean Countries

    Science.gov (United States)

    Valero, María Adela; Periago, María Victoria; Pérez-Crespo, Ignacio; Angles, René; Villegas, Fidel; Aguirre, Carlos; Strauss, Wilma; Espinoza, José R.; Herrera, Patricia; Terashima, Angelica; Tamayo, Hugo; Engels, Dirk; Gabrielli, Albis Francesco; Mas-Coma, Santiago

    2012-01-01

    Background Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA) was evaluated, using classical techniques for egg detection for comparison. Methodology and Findings A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD) and infection intensity by eggs per gram of feces (epg) in Cajamarca low burden cases (<400 epg), nor in Huacullani high burden cases (≥400 epg), although there was in Huacullani low burden cases (<400 epg). Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg). Conclusions The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase

  11. Field evaluation of a coproantigen detection test for fascioliasis diagnosis and surveillance in human hyperendemic areas of Andean countries.

    Directory of Open Access Journals (Sweden)

    María Adela Valero

    Full Text Available Emergence of human fascioliasis prompted a worldwide control initiative including a pilot study in a few countries. Two hyperendemic areas were chosen: Huacullani, Northern Altiplano, Bolivia, representing the Altiplanic transmission pattern with high prevalences and intensities; Cajamarca valley, Peru, representing the valley pattern with high prevalences but low intensities. Coprological sample collection, transport and study procedures were analyzed to improve individual diagnosis and subsequent treatments and surveillance activities. Therefore, a coproantigen-detection technique (MM3-COPRO ELISA was evaluated, using classical techniques for egg detection for comparison.A total of 436 and 362 stool samples from schoolchildren of Huacullani and Cajamarca, respectively, were used. Positive samples from Huacullani were 24.77% using the MM3-COPRO technique, and 21.56% using Kato-Katz. Positive samples from Cajamarca were 11.05% using MM3-COPRO, and 5.24% using rapid sedimentation and Kato-Katz. In Huacullani, using Kato-Katz as gold standard, sensitivity and specificity were 94.68% and 98.48%, respectively, and using Kato-Katz and COPRO-ELISA test together, they were 95.68% and 100%. In Cajamarca, using rapid sedimentation and Kato-Katz together, results were 94.73% and 93.58%, and using rapid sedimentation, Kato-Katz and copro-ELISA together, they were 97.56% and 100%, respectively. There was no correlation between coproantigen detection by optical density (OD and infection intensity by eggs per gram of feces (epg in Cajamarca low burden cases (<400 epg, nor in Huacullani high burden cases (≥ 400 epg, although there was in Huacullani low burden cases (<400 epg. Six cases of egg emission appeared negative by MM3-COPRO, including one with a high egg count (1248 epg.The coproantigen-detection test allows for high sensitivity and specificity, fast large mass screening capacity, detection in the chronic phase, early detection of treatment failure

  12. A pilot study to evaluate an efficient testing strategy for surveillance ...

    African Journals Online (AJOL)

    Introduction: Control strategies for schistosomiasis depend on the understanding of the population specific magnitude of the infection. We present pilot results of a testing strategy suggested by theoretical statistical investigation that lowers cost yet retains similar accuracy profile as the standard Kato-Katz technique.

  13. Use of Reactor Pressure Vessel Surveillance Materials for Extended Life Evaluations Using Power and Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Server, W.L.; Nanstad, R.K.; Odette, G.R.

    2012-01-01

    The most important component in assuring safety of the nuclear power plant is the reactor pressure (RPV). Surveillance programs have been designed to cover the licensed life of operating nuclear RPVs. The original surveillance programs were designed when the licensed life was 40 years. More than one-half of the operating nuclear plants in the USA have an extended license out to 60 years, and there are plans to continue to operate many plants out to 80 years. Therefore, the surveillance programs have had to be adjusted or enhanced to generate key data for 60 years, and now consideration must be given for 80 or more years. To generate the necessary data to assure safe operation out to these extended license lives, test reactor irradiations have been initiated with key RPV and model alloy steels, which include several steels irradiated in the current power reactor surveillance programs out to relatively high fluence levels. These data are crucial in understanding the radiation embrittlement mechanisms and to enable extrapolation of the irradiation effects on mechanical properties for these extended time periods. This paper describes the potential radiation embrittlement mechanisms and effects when assessing much longer operating times and higher neutron fluence levels. Potential methods for adjusting higher neutron flux test reactor data for use in predicting power reactor vessel conditions are discussed. (author)

  14. Surveillance test of OWL-2 inpile tube

    International Nuclear Information System (INIS)

    Shimizu, Masatsugu; Itoh, Noboru

    1976-08-01

    A series of irradiation surveillance tests performed in integrity evaluation of an inpile tube for the test loop OWL-2 are described. Specimens were exposed to the neutron fluences from 1 x 10 20 to 3.4 x 10 21 n/cm 2 (>1 MeV), and subjected to post-irradiation tensile test at room temperature and service temperature 285 0 C. The strength increased and the ductility decreased with increasing neutron fluence. The reduction in fracture ductility due to neutron irradiation in the fluence range was insignificant, and the elongation of 33% was retained even for the maximum neutron fluence at 285 0 C. Little decrease of the ductility with fluence indicates that the tube would be in service for long time, ie to the integral fluence of 3.4 x 10 21 n/cm 2 . (auth.)

  15. Evaluation of the novel respiratory virus surveillance program: Pediatric Early Warning Sentinel Surveillance (PEWSS).

    Science.gov (United States)

    Armour, Patricia A; Nguyen, Linh M; Lutman, Michelle L; Middaugh, John P

    2013-01-01

    Infections caused by respiratory viruses are associated with recurrent epidemics and widespread morbidity and mortality. Routine surveillance of these pathogens is necessary to determine virus activity, monitor for changes in circulating strains, and plan for public health preparedness. The Southern Nevada Health District in Las Vegas, Nevada, recruited five pediatric medical practices to serve as sentinel sites for the Pediatric Early Warning Sentinel Surveillance (PEWSS) program. Sentinel staff collected specimens throughout the year from ill children who met the influenza-like illness case definition and submitted specimens to the Southern Nevada Public Health Laboratory for molecular testing for influenza and six non-influenza viruses. Laboratory results were analyzed and reported to the medical and general communities in weekly bulletins year-round. PEWSS data were also used to establish viral respiratory seasonal baselines and in influenza vaccination campaigns. The surveillance program was evaluated using the Centers for Disease Control and Prevention's (CDC's) Updated Guidelines for Evaluating Public Health Surveillance Systems. PEWSS met three of six program usefulness criteria and seven of nine surveillance system attributes, which exceeded the CDC Guidelines evaluation criteria for a useful and complete public health surveillance program. We found that PEWSS is a useful and complete public health surveillance system that is simple, flexible, accessible, and stable.

  16. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Younggwang nuclear power plant unit1

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 1 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.555E+18, 1.662E+19, 3.358E+19, and 4.521E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.859 for the 1st through 4th testing and the calculational uncertainty, 11.80% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.551E+19 n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.929E+19, 4.880E+19, 5.831E+19 and 6.782E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 1 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 4 refs., 41 figs., 35 tabs. (Author)

  17. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Yonggwang nuclear power plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-02-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.762E+18, 1.5391E+19, 3.5119E+19, and 4.2610E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.899 for the 1st through 4th testing and the calculational uncertainty, 12.3% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.357E+19 n/cm{sup 2} based on the end of 11th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.525E+19, 4.337E+19, 5.148E+19 and 5.960E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 42 tabs. (Author)

  18. Surveillance test of the JMTR core components

    International Nuclear Information System (INIS)

    Takeda, Takashi; Amezawa, Hiroo; Tobita, Kenji

    1986-02-01

    Surveillance test for the core components of Japan Materials Testing Reactor (JMTR) was started in 1966, and completed in 1985 without one capsule. Most of capsules in the program, except one beryllium specimens, were removed from the core, and carred out the post-irradiation tests at the JMTR Hot Laboratory. The data is applied to review of JMTR core components management plan. JMTR surveillance test was carried out with several kind of materials of JMTR core components, Berylium as the reflector, Hafnium as the neutron absorber of control rod, 17-4PH stainless steel as a roller spring of the control rod, and 304 stainless steel as the grid plate. Results are described in this report. (author)

  19. The modification and evaluation of an ELISA test for the surveillance of Mycobacterium avium subsp. paratuberculosis infection in wild ruminants

    Directory of Open Access Journals (Sweden)

    Pruvot Mathieu

    2013-01-01

    Full Text Available Abstract Background Enzyme-linked immunosorbent assay (ELISA is often used to test wildlife samples for Mycobacterium avium subsp. paratuberculosis (MAP infection. However, commercially available kits are only validated for use with domestic ruminant species. A literature review was performed to document the current use of MAP serum ELISA in wild and semi-domestic ruminants. We then modified and evaluated a commercial ELISA kit (IDEXX Mycobacterium paratuberculosis Antibody Test Kit for use with species for which it was not originally developed: elk (Cervus elaphus, bison (Bison bison and caribou (Rangifer tarandus. We tested the affinity of different conjugates for immunoglobulin G (IgG isolated from these species, performed checkerboard tests to determine the optimal dilutions of samples and conjugates, and established cut-off values using two different methods: a Receiver Operational Curve on a panel of known samples for elk, and an alternate method involving a panel of unknown serum samples for the three species. Results We found that the anti-bovine conjugate included in the IDEXX ELISA kit has limited affinity for elk, bison, and caribou IgG. Protein G showed good affinity for IgG of all three species, while anti-deer conjugate also bound elk and caribou IgG. Using Protein G with elk serum, a cut-off sample-to-positive (S/P value of 0.22 was selected, resulting in a sensitivity and specificity of 73% and 90%, respectively, whereas, using an anti-deer conjugate with elk serum, an S/P cut-off value of 0.29 gave a sensitivity of 68%, with 100% specificity. Cut-off values for bison and caribou using the Protein G conjugate were 0.17 and 0.25 respectively. Conclusions Due to incomplete reporting and a lack of test validation, it is difficult to critically appraise results of many sero-surveys that have previously been done for MAP in wildlife. Commercial ELISA kits may have limited or no capacity to detect antibodies from species other than for

  20. Effects of Forgetting Phenomenon on Surveillance Test Interval

    International Nuclear Information System (INIS)

    Lee, Ho-Joong; Jang, Seung-Cheol

    2007-01-01

    Technical Specifications (TS) requirements for nuclear power plants (NPPs) define Surveillance Requirements (SRs) to assure safety during operation. SRs include surveillance test intervals (STIs) and the optimization of the STIs is one of the main issues in risk-informed applications. Surveillance tests are required in NPPs to detect failures in standby equipment to assure their availability in an accident. However, operating experience of the plants suggests that, in addition to the beneficial effects of detecting latent faults, the tests also may have adverse effects on plant operation or equipment; e.g., plant transient caused by the test and wear-out of safety system equipment due to repeated testing. Recent studies have quantitatively evaluated both the beneficial and adverse effects of testing to decide on an acceptable test interval. The purpose of this research is to investigate the effects of forgetting phenomenon on STI. It is a fundamental human characteristic that a person engaged in a repetitive task will improve his performance over time. The learning phenomenon is observed by the decrease in operation time per unit as operators gain experience by performing additional tasks. However, once there is a break of sufficient length, forgetting starts to take place. In surveillance tests, the most common factor to determine the amount of forgetting is the length of STI, where the longer the STI, the greater the amount of forgetting

  1. Evaluation of a radioactive aerosol surveillance system

    International Nuclear Information System (INIS)

    Scripsick, R.C.; Stafford, R.G.; Beckman, R.J.; Tillery, M.I.; Romero, P.O.

    Measurements of the dilution of air contaminants between worker breathing zone and area air samplers were made by releasing a test aerosol in a workroom equipped with an aerosol surveillance system. The data were used to evaluate performance, and suggest improvements in design of the workroom's alarming air monitor system. It was found that a breathing zone concentration of 960 times the maximum permissible concentration in air (MPC/sub a/) for a half-hour was required to trigger alarms of the existing monitoring system under some release conditions. Alternative air monitor placement, suggested from dilution measurements, would reduce this average triggering concentration to 354 MPC/sub a/. Deployment of additional air monitors could further reduce the average triggering concentration to 241 MPC/sub a/. The relation between number of monitors and triggering concentration was studied. No significant decrease in average triggering concentration was noted for arrays containing greater than five monitors

  2. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  3. The relaxation of ESFAS/RPS surveillance test requirements

    International Nuclear Information System (INIS)

    Hah, Yung Joon; Koo, Jung Eui; Choi, Hae Yoon

    1994-01-01

    The surveillance test requirement of ESFAS/RPS is reviewed for 950 MWe class westinghouse reactor (YGN unit 1 and 2, Kori unit 3 and 4). The current requirements of frequent test and maintenance in the tech. spec. can lead to human errors, jeopardizing safety of the plant, and reduction in the availability of the plant. Meanwhile, the ESFAS designs do not provide for complete online testing capabilities for their protection systems. Therefore, ESFAS slave relays cannot be tested during plant operation as actuation of associated equipment could result in unwanted plant transient or trip conditions. In this study, westinghouse's PSA results, NRC recommendation and NRC approval status for specific U.S. nuclear power plant have been reviewed and evaluated. Since YGN 1 and 2 and Kori 3 and 4 are essentially the same plant as the operating westinghouse plant in the U.S., it is expected that YGN 1 and 2 and Kori 3 and 4 will be justified for having ESFAS/RPS surveillance test requirements relaxation program. Finally the extension of surveillance testing intervals and allowed outage times for test and maintenance will be verified by PSA program for YGN 1 and 2 and Kori 3 and 4. Various findings during the project can be used in the possible future revision of current technical specification with further refinements through the PSA program for YGN 1 and 2 and Kori 3 and 4. (Author) 10 refs., 8 figs., 24 tabs

  4. The relaxation of ESFAS/RPS surveillance test requirements

    Energy Technology Data Exchange (ETDEWEB)

    Hah, Yung Joon; Koo, Jung Eui; Choi, Hae Yoon [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    The surveillance test requirement of ESFAS/RPS is reviewed for 950 MWe class westinghouse reactor (YGN unit 1 and 2, Kori unit 3 and 4). The current requirements of frequent test and maintenance in the tech. spec. can lead to human errors, jeopardizing safety of the plant, and reduction in the availability of the plant. Meanwhile, the ESFAS designs do not provide for complete online testing capabilities for their protection systems. Therefore, ESFAS slave relays cannot be tested during plant operation as actuation of associated equipment could result in unwanted plant transient or trip conditions. In this study, westinghouse`s PSA results, NRC recommendation and NRC approval status for specific U.S. nuclear power plant have been reviewed and evaluated. Since YGN 1 and 2 and Kori 3 and 4 are essentially the same plant as the operating westinghouse plant in the U.S., it is expected that YGN 1 and 2 and Kori 3 and 4 will be justified for having ESFAS/RPS surveillance test requirements relaxation program. Finally the extension of surveillance testing intervals and allowed outage times for test and maintenance will be verified by PSA program for YGN 1 and 2 and Kori 3 and 4. Various findings during the project can be used in the possible future revision of current technical specification with further refinements through the PSA program for YGN 1 and 2 and Kori 3 and 4. (Author) 10 refs., 8 figs., 24 tabs.

  5. Evaluating technologies of oil spill surveillance

    International Nuclear Information System (INIS)

    Hover, G.L.

    1993-01-01

    Surveillance and monitoring of oil in the marine environment imposes a broad spectrum of remote sensing requirements. At the US Coast Guard Research ampersand Development Center, the environmental safety branch is sponsoring oil spill remote sensing research in four areas of technology: Synthetic aperture radar (SAR), Frequency-scanning microwave radiometry (FSR), Laser fluorosensing (LFS), and Forward-looking infrared (FLIR) imagers. SAR technology uses sophisticated signal processing to overcome prior limitations, providing images of higher and more uniform spatial acuity which may enable interpreters to more-readily distinguish petroleum slicks from others. The ability to determine the distribution of oil thickness within a slick is necessary when an estimate of oil volume is desired. Scientists at MIT have formulated a new approach to radiometric oil thickness measurement that takes advantage of recent advances in electronic component technology. The initial data collected with a prototype FSR instrument have validated the FSR concept and more work is ongoing. The Coast Guard is co-funding a program to demonstrate and evaluate the capabilities of an airborne laser fluorosensor to support oil spill response operations. During a controlled test, the instrument successfully demonstrated an ability to detect oil on water, ice, and various beach surfaces. Additional testing included different oil types and allowed for weathering. Data analysis is ongoing. Recent developments in infrared imager technology have produced a wide variety of off-the-shelf, portable cameras that could potentially provide a rapid-response spill assessment capability. The R ampersand D Center has been involved in the testing of many of these sensors

  6. Multi-Camera Persistent Surveillance Test Bed

    National Research Council Canada - National Science Library

    Baran, David; O'Brien, Barry; Fung, Nick; Kovach, Jesse; Miller, David

    2007-01-01

    .... Small reconnaissance surveillance and target acquisition (RSTA) platforms have the ability to cooperate through information sharing to increase the situational awareness over a region of interest (RSTA...

  7. 2003 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Security, Office of Illness and Injury Prevention Programs

    2007-05-23

    Annual Illness and Injury Surveillance Program report for 2003 for the Nevada Test Site. The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  8. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Background: Rivers State has been reported to have the highest HIV prevalence of all the thirty-six states in Nigeria. HIV surveillance system generates information for timely and appropriate public health action. Evaluation of the surveillance system is vital in ensuring that the purpose of the surveillance system is being met.

  9. Evaluation of Surveillance for Documentation of Freedom from Bovine Tuberculosis

    Directory of Open Access Journals (Sweden)

    Liza R. Nielsen

    2013-06-01

    Full Text Available The objective was to study how surveillance for bovine tuberculosis (bTB could be made more resource-effective in a bTB free country. A stochastic scenario tree model was developed to: (1 evaluate the sensitivity (CSe of four surveillance system components (SSC (i.e., meat inspection of slaughtered domestic cattle, farmed deer and pigs, and tuberculin testing of adult export cattle given that bTB would enter one of these components, (2 estimate the probability of freedom (PFree from bTB over time, and (3 evaluate how future alternative programmes based on visual meat inspection would affect the confidence in freedom from bTB at the very low animal-level design prevalence 0.0002% and a low probabilities of introduction (1%. All, except the export cattle component reached a PFree above 96% within five years. The PFree was slightly reduced if surveillance was changed to visual inspection, e.g., PFree was reduced from 96.5% to 94.3% in the cattle component, and from 98.5% to 97.7% in the pig component after 24 years. In conclusion, visual meat inspection of pigs and cattle will only reduce the confidence in freedom from bTB slightly. However, with negligible probability of introduction (0.1% the PFree could be maintained well above 99% in the cattle, pigs and deer components, which highlights the importance of rigid testing and quarantine procedures in trade of livestock.

  10. Designing and evaluating risk-based surveillance systems

    DEFF Research Database (Denmark)

    Willeberg, Preben; Nielsen, Liza Rosenbaum; Salman, Mo

    2012-01-01

    Risk-based surveillance systems reveal occurrence of disease or infection in a sample of population units, which are selected on the basis of risk factors for the condition under study. The purpose of such systems for supporting practical animal disease policy formulations and management decisions...... with prudent use of resources while maintaining acceptable system performance. High-risk category units are selected for testing by identification of the presence of specific high-risk factor(s), while disregarding other factors that might also influence the risk. On this basis we argue that the most...... applicable risk estimate for use in designing and evaluating a risk-based surveillance system would be a crude (unadjusted) relative risk, odds ratio or apparent prevalence. Risk estimates found in the published literature, however, are often the results of multivariable analyses implicitly adjusting...

  11. The technology development for surveillance test of reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Sun Phil; Park, Day Young; Choi, Kwen Jai

    1997-12-01

    Benchmark test was performed in accordance with the requirement of US NRC Reg. Guide DG-1053 for Kori unit-1 in order to determine best-estimated fast neutron fluence irradiated into reactor vessel. Since the uncertainty of radiation analysis comes from the calculation error due to neutron cross-section data, reactor core geometrical dimension, core source, mesh density, angular expansion and convergence criteria, evaluation of calculational uncertainty due to analytical method was performed in accordance with the regulatory guide and the proof was performed for entire analysis by comparing the measurement value obtained by neutron dosimetry located in surveillance capsule. Best-estimated neutron fluence in reactor vessel was calculated by bias factor, neutron flux measurement value/calculational value, from reanalysis result from previous 1st through 4th surveillance testing and finally fluence prediction was performed for the end of reactor life and the entire period of plant life extension. Pressurized thermal shock analysis was performed in accordance with 10 CFR 50.61 using the result of neutron fluence analysis in order to predict the life of reactor vessel material and the criteria of safe operation for Kori unit 1 was reestablished. (author). 55 refs., 55 figs.

  12. Basic data for surveillance test on core support graphite structures for the high temperature engineering test reactor (HTTR)

    International Nuclear Information System (INIS)

    Sumita, Junya; Shibata, Taiju; Kikuchi, Takayuki; Iyoku, Tatsuo; Fujimoto, Nozomu; Ishihara, Masahiro; Sawa, Kazuhiro

    2007-02-01

    Both of the visual inspection by a TV camera and the measurement of material properties by surveillance test on core support graphite structures are planned for the High Temperature Engineering Test Reactor (HTTR) to confirm their structural integrity and characteristics. The surveillance test is aimed to investigate the change of material properties by aging effects such as fast neutron irradiation and oxidation. The obtained data will be used not only for evaluating the structural integrity of the core support graphite structures of the HTTR but also for design of advanced Very High Temperature Reactor (VHTR) discussed at generation IV international forum. This report describes the initial material properties of surveillance specimens before installation and installed position of surveillance specimens in the HTTR. (author)

  13. An Evaluation of Provincial Infectious Disease Surveillance Reports in Ontario

    OpenAIRE

    Chan, Ellen; Barnes, Morgan E.; Sharif, Omar

    2017-01-01

    Context: Public Health Ontario (PHO) publishes various infectious disease surveillance reports, but none have yet been formally evaluated. Objective: PHO evaluated its monthly and annual infectious disease surveillance reports to assess public health stakeholders' current perception of the products and to develop recommendations for improving future products. Design: An evaluation consisting of an online survey and a review of public Web sites of other jurisdictions with similar annual report...

  14. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  15. Evaluation and surveillance of radioactive releases of nuclear installations

    International Nuclear Information System (INIS)

    Hartmann, Ph.

    2002-01-01

    The two days organised by the section Environment of the SFRP have to objective to connect experts in radiation protection in order to debate around the following questions: the actual evaluations modes of releases impacts from nuclear installations, the organisation of the surveillance, to favour the implication of local actors in the evaluation and surveillance around nuclear facilities, the evolutions to envisage. (N.C.)

  16. Evaluation of two surveillance methods for surgical site infection

    Directory of Open Access Journals (Sweden)

    M. Haji Abdolbaghi

    2006-08-01

    Full Text Available Background: Surgical wound infection surveillance is an important facet of hospital infection control processes. There are several surveillance methods for surgical site infections. The objective of this study is to evaluate the accuracy of two different surgical site infection surveillance methods. Methods: In this prospective cross sectional study 3020 undergoing surgey in general surgical wards of Imam Khomeini hospital were included. Surveillance methods consisted of review of medical records for postoperative fever and review of nursing daily note for prescription of antibiotics postoperatively and during patient’s discharge. Review of patient’s history and daily records and interview with patient’s surgeon and the head-nurse of the ward considered as a gold standard for surveillance. Results: The postoperative antibiotic consumption especially when considering its duration is a proper method for surgical wound infection surveillance. Accomplishments of a prospective study with postdischarge follow up until 30 days after surgery is recommended. Conclusion: The result of this study showed that postoperative antibiotic surveillance method specially with consideration of the antibiotic usage duration is a proper method for surgical site infection surveillance in general surgery wards. Accomplishments of a prospective study with post discharge follow up until 30 days after surgery is recommended.

  17. Testing of mobile surveillance robot at a nuclear power plant

    International Nuclear Information System (INIS)

    White, J.R.; Harvey, H.W.; Farnstrom, K.A.

    1987-01-01

    In-plant testing of a mobile surveillance robot (SURBOT) was performed at the Browns Ferry Nuclear Plant by TVA personnel. The results verified that SURBOT can be used for remote surveillance in 54 separate controlled radiation rooms at the plant. High-quality color video, audio, and other data are collected, digitized by an on-board computer, and transmitted through a cable to the control console for real-time display and videotaping. TVA projects that the use of SURBOT for surveillance during plant operation will produce annual savings of about 100 person-rem radiation exposure and $200,000 in operating costs. Based on the successful results of this program, REMOTEC is now commercializing the SURBOT technology on both wheeled and tracked mobile robots for use in nuclear power plants and other hazardous environments

  18. An Evaluation of Provincial Infectious Disease Surveillance Reports in Ontario.

    Science.gov (United States)

    Chan, Ellen; Barnes, Morgan E; Sharif, Omar

    Public Health Ontario (PHO) publishes various infectious disease surveillance reports, but none have yet been formally evaluated. PHO evaluated its monthly and annual infectious disease surveillance reports to assess public health stakeholders' current perception of the products and to develop recommendations for improving future products. An evaluation consisting of an online survey and a review of public Web sites of other jurisdictions with similar annual reports. For the online survey, stakeholder organizations targeted were the 36 local public health units and the Health health ministry in Ontario, Canada. Survey participants included epidemiologists, managers, directors, and other public health practitioners from participating organizations. Online survey respondents' awareness and access to the reports, their rated usefulness of reports and subsections, and suggestions for improving usefulness; timeliness of select annual reports from other jurisdictions based on the period from data described to report publication. Among 57 survey respondents, between 74% and 97% rated each report as useful; the most common use was for situational awareness. Respondents ranked timeliness as the most important attribute of surveillance reports, followed by data completeness. Among 6 annual reports reviewed, the median time to publication was 11.5 months compared with 23.2 months for PHO. Recommendations based on this evaluation have already been applied to the monthly report (eg, focusing on the most useful sections) and have become key considerations when developing future annual reports and other surveillance reporting tools (eg, need to provide more timely reports). Other public health organizations may also use this evaluation to inform aspects of their surveillance report development and evaluation. The evaluation results have provided PHO with direction on how to improve its provincial infectious disease surveillance reporting moving forward, and formed a basis for

  19. Surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Coeckelbergh, Mark; Matzner, Tobias

    Studying surveillance involves raising questions about the very nature of concepts such as information, technology, identity, space and power. Besides the maybe all too obvious ethical issues often discussed with regard to surveillance, there are several other angles and approaches that we should...... like to encourage. Therefore, our panel will focus on the philosophical, yet non-ethical issues of surveillance in order to stimulate an intense debate with the audience on the ethical implications of our enquiries. We also hope to provide a broader and deeper understanding of surveillance....

  20. Occupational health surveillance: Pulmonary function testing in emergency responders

    Directory of Open Access Journals (Sweden)

    James D McCluskey

    2014-01-01

    Full Text Available Emergency responders may be exposed to a variety of fumes, gases, and particulates during the course of their job that can affect pulmonary function (PF and require the use of respiratory protection. This investigation used occupational health monitoring examination data to characterize PF in a population currently employed as emergency responders. PF tests for workers who required health examinations to ensure fitness for continued respirator use were compared to the National Health and Nutrition Examination Survey (NHANES III Raw Spirometry database to determine if decreased PF was associated with employment as an emergency responder. The results of this research indicated that the emergency responders experienced a modest, but statistically significant, increase in forced expiratory volume in 1 second (FEV1 and forced vital capacity (FVC mean values over the NHANES III population in both total and stratified analyses, including stratification by age, gender, height, and smoking history. Results are likely due to a combination of effectively controlled exposures in the workplace, and the healthy worker effect among long-term workers. PF testing required by the Occupational and Safety Health Administration (OSHA has substantial utility for conducting occupational surveillance at the population level. In this investigation, we were able to quickly evaluate if abnormal PF existed in an industrial sector known to have exposures that, when uncontrolled, can lead to PF impairment.

  1. Evaluating surveillance strategies for the early detection of low pathogenicity avian influenza infections.

    Science.gov (United States)

    Comin, Arianna; Stegeman, Arjan; Marangon, Stefano; Klinkenberg, Don

    2012-01-01

    In recent years, the early detection of low pathogenicity avian influenza (LPAI) viruses in poultry has become increasingly important, given their potential to mutate into highly pathogenic viruses. However, evaluations of LPAI surveillance have mainly focused on prevalence and not on the ability to act as an early warning system. We used a simulation model based on data from Italian LPAI epidemics in turkeys to evaluate different surveillance strategies in terms of their performance as early warning systems. The strategies differed in terms of sample size, sampling frequency, diagnostic tests, and whether or not active surveillance (i.e., routine laboratory testing of farms) was performed, and were also tested under different epidemiological scenarios. We compared surveillance strategies by simulating within-farm outbreaks. The output measures were the proportion of infected farms that are detected and the farm reproduction number (R(h)). The first one provides an indication of the sensitivity of the surveillance system to detect within-farm infections, whereas R(h) reflects the effectiveness of outbreak detection (i.e., if detection occurs soon enough to bring an epidemic under control). Increasing the sampling frequency was the most effective means of improving the timeliness of detection (i.e., it occurs earlier), whereas increasing the sample size increased the likelihood of detection. Surveillance was only effective in preventing an epidemic if actions were taken within two days of sampling. The strategies were not affected by the quality of the diagnostic test, although performing both serological and virological assays increased the sensitivity of active surveillance. Early detection of LPAI outbreaks in turkeys can be achieved by increasing the sampling frequency for active surveillance, though very frequent sampling may not be sustainable in the long term. We suggest that, when no LPAI virus is circulating yet and there is a low risk of virus introduction

  2. Evaluating surveillance strategies for the early detection of low pathogenicity avian influenza infections.

    Directory of Open Access Journals (Sweden)

    Arianna Comin

    Full Text Available In recent years, the early detection of low pathogenicity avian influenza (LPAI viruses in poultry has become increasingly important, given their potential to mutate into highly pathogenic viruses. However, evaluations of LPAI surveillance have mainly focused on prevalence and not on the ability to act as an early warning system. We used a simulation model based on data from Italian LPAI epidemics in turkeys to evaluate different surveillance strategies in terms of their performance as early warning systems. The strategies differed in terms of sample size, sampling frequency, diagnostic tests, and whether or not active surveillance (i.e., routine laboratory testing of farms was performed, and were also tested under different epidemiological scenarios. We compared surveillance strategies by simulating within-farm outbreaks. The output measures were the proportion of infected farms that are detected and the farm reproduction number (R(h. The first one provides an indication of the sensitivity of the surveillance system to detect within-farm infections, whereas R(h reflects the effectiveness of outbreak detection (i.e., if detection occurs soon enough to bring an epidemic under control. Increasing the sampling frequency was the most effective means of improving the timeliness of detection (i.e., it occurs earlier, whereas increasing the sample size increased the likelihood of detection. Surveillance was only effective in preventing an epidemic if actions were taken within two days of sampling. The strategies were not affected by the quality of the diagnostic test, although performing both serological and virological assays increased the sensitivity of active surveillance. Early detection of LPAI outbreaks in turkeys can be achieved by increasing the sampling frequency for active surveillance, though very frequent sampling may not be sustainable in the long term. We suggest that, when no LPAI virus is circulating yet and there is a low risk of virus

  3. Selection and evaluation of video tape recorders for surveillance applications

    International Nuclear Information System (INIS)

    Martinez, R.L.

    1988-01-01

    Unattended surveillance places unique requirements on video recorders. One such requireemnt, extended operational reliability, often cannot be determined from the manufacturers' data. Subsequent to market surveys and preliminary testing, the Sony 8mm EVO-210 recorder was selected for use in the Modular Integrated Video System (MIVS), while concurrently undergoing extensive reliability testing. A microprocessor based controller was developed to life test and evaluate the performance of the video cassette recorders. The controller has the capability to insert a unique binary count in the vertical interval of the recorder video signal for each scene. This feature allows for automatic verification of the recorded data using a MIVS Review Station. Initially, twenty recorders were subjected to the accelerated lift test, which involves recording one scene (eight video frames) every 15 seconds. The recorders were operated in the exact manner in which they are utilized in the MIVS. This paper describes the results of the preliminary testing, accelerated life test and the extensive testing on 130 Sony EVO-210 recorders

  4. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Stallmann, F.W.; Guthrie, G.; McElroy, W.N.

    1985-01-01

    The ORR-PSF benchmark experiment was designed to simulate the surveillance capsule-pressure vessel configuration in power reactors and to test the validity of procedures which determine the radiation damage in the vessel from test results in the surveillance capsule. The PSF metallurgical blind test was initiated to give participants an opportunity to test their current embrittlement prediction methodologies. Experimental results were withheld from the participants except for the type of information which is normally contained in surveillance reports. Preliminary analysis of the PSF metallurgical blind test results shows that: (1) current prediction methodologies, as used by the PSF Blind Test participants, are adequate, falling within +- 20 0 C of the measured values for Δ NDT. None of the different methods is clearly superior; (2) the proposed revision of Reg. Guide 1.99 (Rev. 2) gives a better representation of the fluence and chemistry dependency of Δ NDT than the current version (Rev. 1); and (3) fluence rate effects can be seen but not quantified. Fluence spectral effects are too small to be detectable in this experiment. (orig.)

  5. Optimization of Allowed Outage Time and Surveillance Test Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Al-Dheeb, Mujahed; Kang, Sunkoo; Kim, Jonghyun [KEPCO international nuclear graduate school, Ulsan (Korea, Republic of)

    2015-10-15

    The primary purpose of surveillance testing is to assure that the components of standby safety systems will be operable when they are needed in an accident. By testing these components, failures can be detected that may have occurred since the last test or the time when the equipment was last known to be operational. The probability a system or system component performs a specified function or mission under given conditions at a prescribed time is called availability (A). Unavailability (U) as a risk measure is just the complementary probability to A(t). The increase of U means the risk is increased as well. D and T have an important impact on components, or systems, unavailability. The extension of D impacts the maintenance duration distributions for at-power operations, making them longer. This, in turn, increases the unavailability due to maintenance in the systems analysis. As for T, overly-frequent surveillances can result in high system unavailability. This is because the system may be taken out of service often due to the surveillance itself and due to the repair of test-caused failures of the component. The test-caused failures include those incurred by wear and tear of the component due to the surveillances. On the other hand, as the surveillance interval increases, the component's unavailability will grow because of increased occurrences of time-dependent random failures. In that situation, the component cannot be relied upon, and accordingly the system unavailability will increase. Thus, there should be an optimal component surveillance interval in terms of the corresponding system availability. This paper aims at finding the optimal T and D which result in minimum unavailability which in turn reduces the risk. Applying the methodology in section 2 to find the values of optimal T and D for two components, i.e., safety injection pump (SIP) and turbine driven aux feedwater pump (TDAFP). Section 4 is addressing interaction between D and T. In general

  6. Optimization of Allowed Outage Time and Surveillance Test Intervals

    International Nuclear Information System (INIS)

    Al-Dheeb, Mujahed; Kang, Sunkoo; Kim, Jonghyun

    2015-01-01

    The primary purpose of surveillance testing is to assure that the components of standby safety systems will be operable when they are needed in an accident. By testing these components, failures can be detected that may have occurred since the last test or the time when the equipment was last known to be operational. The probability a system or system component performs a specified function or mission under given conditions at a prescribed time is called availability (A). Unavailability (U) as a risk measure is just the complementary probability to A(t). The increase of U means the risk is increased as well. D and T have an important impact on components, or systems, unavailability. The extension of D impacts the maintenance duration distributions for at-power operations, making them longer. This, in turn, increases the unavailability due to maintenance in the systems analysis. As for T, overly-frequent surveillances can result in high system unavailability. This is because the system may be taken out of service often due to the surveillance itself and due to the repair of test-caused failures of the component. The test-caused failures include those incurred by wear and tear of the component due to the surveillances. On the other hand, as the surveillance interval increases, the component's unavailability will grow because of increased occurrences of time-dependent random failures. In that situation, the component cannot be relied upon, and accordingly the system unavailability will increase. Thus, there should be an optimal component surveillance interval in terms of the corresponding system availability. This paper aims at finding the optimal T and D which result in minimum unavailability which in turn reduces the risk. Applying the methodology in section 2 to find the values of optimal T and D for two components, i.e., safety injection pump (SIP) and turbine driven aux feedwater pump (TDAFP). Section 4 is addressing interaction between D and T. In general

  7. Environmental surveillance report for the Nevada Test Site (January 1981 through December 1981)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1982-05-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1981 through December 1981. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  8. Environmental-surveillance report for the Nevada Test Site (January 1982 through December 1982)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1983-06-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted from January 1982 through December 1982. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG's) is established

  9. Environmental surveillance report for the Nevada Test Site (January 1980-December 1980)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1981-01-01

    Results are presented for the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1980 through December 1980. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  10. The technology development for surveillance test of RPV materials 2

    International Nuclear Information System (INIS)

    Chang, Kee Ok; Lee, Sam Lai; Kim, Byoung Chul; Choi, Sun Pil; Choi, Kwen Jai

    1998-12-01

    Irradiation-induced changes in mechanical properties and magnetic parameters were measured and compared to explore possible correlations for Mn-Mo-Ni low alloy steel surveillance specimens which were irradiated to a neutron fluence of 2.4 x 10 1 9n/cm 2 (E≥1.0 MeV) in a typical pressurized water reactor environment at about 288 deg C. For mechanical property parameters, microvickers hardness, tensile and Charpy impact test were performed and Barkhausen Noise(BN) amplitude, coercivity, maximum induction were measured for magnetic parameters, respectively. Results of mechanical property measurements showed an increase in yield and tensil strength, microvickers hardness 41J indexed RT NDT and a decrease in upper shelf energy irrespective of base and weld metals. In the case of magnetic measurements, it is found that magnetic remanence, BN amplitude, BN energy have dropped significantly but coercivity has increased rapidly after irradiation. For isothermally heat treated condition of irradiated specimen, BN energy has increased while Vickers microhardness has decreased. Results of BNE and Vickers microhardness are reversed to the results on irradiated condition. All these consistent changes in magnetic parameter and Vickers microhardness measurement, which are thought to be resulted from the interaction between irradiation-induced defects and dislocation, and magnetic domain, respectively, show a possibility that magnetic measurement may be used to the evaluation of material degradation and recovery due to neutron irradiation and heat treatment, respectively, if a relevant large database is prepared. (author). 49 refs., 7 tabs., 23 figs

  11. Is the HIV sentinel surveillance system adequate in China? Findings from an evaluation of the national HIV sentinel surveillance system

    Directory of Open Access Journals (Sweden)

    Marc Bulterys

    2012-11-01

    Full Text Available Background: An external evaluation was conducted to assess the performance of the national HIV sentinel surveillance system (HSS, identify operational challenges at national and local levels and provide recommendations for improvement.Methods: The United States Centers for Disease Control and Prevention’s (CDC Updated Guidelines for Evaluating Public Health Surveillance Systems were followed to assess the key attributes of HSS. Comprehensive assessment activities were conducted, including: using a detailed checklist to review surveillance guidelines, protocols and relevant documents; conducting self-administered, anonymous surveys with 286 local China CDC staff; and carrying out field observations in 32 sentinel sites in four provinces.Results: China has built an extensive HSS with 1888 sentinel sites to monitor HIV epidemic trends by population groups over time. The strengths of HSS lie in its flexibility, simplicity, usefulness and increase in coverage in locations and populations. With its rapid expansion in 2010, HSS faces challenges in maintaining acceptability, timeliness, data quality, representativeness and sustainability.Recommendations: Implementation of the national guidelines should be standardized by strengthening training, monitoring and supervision of all staff involved, including community-based organizations. National surveillance guidelines need to be revised to strengthen data quality and representativeness, particularly to include specific instructions on HIV testing result provision, collection of identifying information, sample size and sampling methods particularly for men who have sex with men (MSM, collection of refusal information, and data interpretation. Sustainability of China’s HSS could be strengthened by applying locally tailored surveillance strategies, strengthening coordination and cooperation among government agencies and ensuring financial and human resources.

  12. Confirmation tests of PWR surveillance capsule shipping container

    International Nuclear Information System (INIS)

    Tomita, N.; Ue, K.; Ohashi, M.; Asada, K.; Yoneda, Y.

    1980-01-01

    Mitsubishi Heavy Industries, Ltd. carried out the confirmation tests to confirm the reliability of the PWR surveillance capsule shipping container and to collect cask design data using a 10-ton weight full scale model at Kobe Shipyard and Engine Works. This report presents the outline of these tests. The B Type container was a cylinder 3289 mm long, 1080 mm in diameter and designed in accordance with the new modified Japanese regulations similar to IAEA regulation. These tests consist of four 9 m drop tests, two 1 m puncture tests, a fire test and an immersion test. In conclusion, safetyness of this container has been proved and various technical data for cask design were also collected through these tests. (author)

  13. Human-centered automation of testing, surveillance and maintenance

    International Nuclear Information System (INIS)

    Bhatt, S.C.; Sun, B.K.H.

    1991-01-01

    Manual surveillance and testing of instrumentation, control and protection systems at nuclear power plants involves system and human errors which can lead to substantial plant down time. Frequent manual testing can also contribute significantly to operation and maintenance cost. Automation technology offers potential for prudent applications at the power plant to reduce testing errors and cost. To help address the testing problems and to harness the benefit of automation application, input from utilities is obtained on suitable automation approaches. This paper includes lessens from successful past experience at a few plants where some island of automation exist. The results are summarized as a set of specifications for semi automatic testing. A human-centered automation methodology is proposed with the guidelines for optimal human/computer division of tasks given. Implementation obstacles for significant changes of testing practices are identified and methods acceptable to nuclear power plants for addressing these obstacles have been suggested

  14. Pain evaluation during gynaecological surveillance in women with Lynch syndrome

    NARCIS (Netherlands)

    Helder-Woolderink, Jorien; de Bock, Geertruida; Hollema, Harry; van Oven, Magda; Mourits, Marian

    To evaluate perceived pain during repetitive annual endometrial sampling at gynaecologic surveillance in asymptomatic women with Lynch syndrome (LS) over time and in addition to symptomatic women without LS, undergoing single endometrial sampling. In this prospective study, 52 women with LS or first

  15. Supplier's evaluation - internal and external audits and surveillance

    International Nuclear Information System (INIS)

    Fowler, J.L.; Derrick, R.

    1976-01-01

    The quality programme for SGHWR type reactors places responsibility upon all purchasers to evaluate potential suppliers' quality systems and to conduct audits and surveillance on the implementation of suppliers' quality assurance programmes during contract performance. This will be carried out in accordance with the requirements of Central Electricity Board standard QA42. It also places a responsibilty on every supplier to conduct in-house audits and surveillance of the effectiveness of his own quality assurance programmes. These procedures are discussed. (U.K.)

  16. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    Science.gov (United States)

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  18. Evaluation of community-based surveillance for Guinea worm, South ...

    African Journals Online (AJOL)

    2012-08-03

    Aug 3, 2012 ... deleted at the Data Manager Level in Loki. Conclusion. Community-based surveillance for guinea worm is a good example of a surveillance system on which an integrated disease surveillance system can be based in countries with poor surveillance like South Sudan. This makes its potential value to ...

  19. Evaluation of a Spotted Fever Group Rickettsia Public Health Surveillance System in Tennessee.

    Science.gov (United States)

    Fill, Mary-Margaret A; Moncayo, Abelardo C; Bloch, Karen C; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-09-01

    Spotted fever group (SFG) rickettsioses are endemic in Tennessee, with ∼2,500 cases reported during 2000-2012. Because of this substantial burden of disease, we performed a three-part evaluation of Tennessee's routine surveillance for SFG rickettsioses cases and deaths to assess the system's effectiveness. Tennessee Department of Health (TDH) SFG rickettsioses surveillance records were matched to three patient series: 1) patients with positive serologic specimens from a commercial reference laboratory during 2010-2011, 2) tertiary medical center patients with positive serologic tests during 2007-2013, and 3) patients identified from death certificates issued during 1995-2014 with SFG rickettsiosis-related causes of death. Chart reviews were performed and patients were classified according to the Council of State and Territorial Epidemiologists' case definition. Of 254 SFG Rickettsia -positive serologic specimens from the reference laboratory, 129 (51%) met the case definition for confirmed or probable cases of rickettsial disease after chart review. The sensitivity of the TDH surveillance system to detect cases was 45%. Of the 98 confirmed or probable cases identified from the medical center, the sensitivity of the TDH surveillance system to detect cases was 34%. Of 27 patients identified by death certificates, 12 (44%) were classified as confirmed or probable cases; four (33%) were reported to TDH, but none were correctly identified as deceased. Cases of SFG rickettsioses were underreported and fatalities not correctly identified. Efforts are needed to improve SFG rickettsiosis surveillance in Tennessee.

  20. Evaluation of satellite technology for pipeline route surveillance and the prevention of third party interference damage

    Energy Technology Data Exchange (ETDEWEB)

    Palmer-Jones, Roland; Hopkins, Phil [Penspen Integrity, Newcastle upon Tyne (United Kingdom)]. E-mail: r.palmer-jones@penspen.com; p.hopkins@penspen.com; Fraser, Andy [Integrated Statistical Solutions (United States)]. E-mail: andy@issquared.co.uk; Dezobry, Jerome [Gas de France, Paris (France)]. E-mail: jerome.dezobry@gazdefrance.com; Merrienboer, Hugo Van [Gasunie, Groningen (Netherlands)]. E-mail: H.A.M.van.Merrienboer@gasunie.nl

    2003-07-01

    The damage caused by Third Party Interference (TPI) is one of the major causes of pipeline failures. Consequently, new technologies for identifying activities that may cause damage to our pipelines are constantly being developed. A recently completed project sponsored by a number of pipeline operators has investigated the use of high-resolution satellites for the integrity management of onshore transmission pipelines. The sponsors were BG Technology (on behalf of Transco), Dansk Olie NatureGas, Gasunie, BP, Gaz de France, Distrigas, and the Health and Safety Executive. The project started with a general review of the satellite technologies available and their potential. The study was then focussed on the identification of activities that might result in damage to the pipeline and the potential of high-resolution optical satellites in identifying hazardous activities. A key element of the study was a comparison with existing surveillance systems, which generally involve regular aerial patrols of the pipeline route. To achieve this a survey was carried out to try and evaluate the costs and benefits of existing systems. In addition a simple model for analysing the cost benefit of pipeline surveillance was constructed, and a functional specification for a surveillance system drafted. Finally the performance of the IKONOS 2 high-resolution satellite system was tested in a controlled experiment using targets placed along a pipeline route. The results of this test were compared with a similar test of helicopter-based surveillance carried out by one of the sponsors. (author)

  1. Pain evaluation during gynaecological surveillance in women with Lynch syndrome.

    Science.gov (United States)

    Helder-Woolderink, Jorien; de Bock, Geertruida; Hollema, Harry; van Oven, Magda; Mourits, Marian

    2017-04-01

    To evaluate perceived pain during repetitive annual endometrial sampling at gynaecologic surveillance in asymptomatic women with Lynch syndrome (LS) over time and in addition to symptomatic women without LS, undergoing single endometrial sampling. In this prospective study, 52 women with LS or first degree relatives who underwent repetitive annual gynaecological surveillance including endometrial sampling of which 33 were evaluated twice or more and 50 symptomatic women without LS who had single endometrial sampling, were included. Pain intensity was registered with VAS scores. Differences in pain intensities between subsequent visits (in LS) and between the two groups were evaluated. The use of painkillers before endometrial sampling was registered. If women with LS decided for preventive surgery, the reason was recorded. The LS group reported a median VAS score of 5.0 (range 0-10) at the first surveillance (n = 52) and at the second visit (n = 24). Women who repeatedly underwent endometrial sampling more often used painkillers for this procedure. During the study period 7/52 (13 %) women with LS choose for preventive surgery, another 4/52 (8 %) refused further endometrial sampling. Painful endometrial sampling was mentioned as main reason to quit screening. The median VAS score of the 50 symptomatic women was 5.0 (range 1-9). Endometrial sampling, irrespective of indication, is a painful procedure, with a median VAS score of 5.0. During subsequent procedures in women with LS, the median pain score does not aggravate although one in five women chose an alternative for endometrial sampling.

  2. Evaluation of surveillance of dengue fever cases in the public health centre of Putat Jaya based on attribute surveillance

    Directory of Open Access Journals (Sweden)

    Zumaroh Zumaroh

    2015-01-01

    Full Text Available Dengue Hemorrhagic Fever (DHF is a public health problem in the village of Putat Jaya which is an endemic area. Surveilans activity in DHF control program is the most important activity in controlling and monitoring disease progression. The program is expected to achieve incidence rate 55/100.000 population. This study aimed to evaluate the implementation of case surveilans in health centre of putat jaya based on attribute surveillance. Attribute surveillance is an indicator that describes the characteristics of the surveillance system. This research was an evaluation research with descriptive study design. As informants were clinic staff who deal specifically with cases of dengue hemorrhagic fever and laboratory workers. The techniques of data collection by interviews and document study. The variables of this study were simplicity, flexibility, acceptability, sensitivity, positive predictive value, representativeness, timeliness, data quality and data stability. It could be seen from Incidence Rate in 2013 has reached 133/100.00 population. The activity of surveilance in the village of Putat Jaya reviewed from disease contol program management was not succeed into decrease incidence rate of DHF. Therefore, dengue control programs in health centers Putat Jaya need to do cross-sector cooperation and cross-program cooperation, strengthening the case reporting system by way increasing in the utilization of information and communication technology electromedia. Keywords: case surveillance, dengue hemorrhagic fever, evaluation, attribute surveillance, Putat Jaya

  3. Evaluation of the influenza sentinel surveillance system in Madagascar, 2009-2014.

    Science.gov (United States)

    Rakotoarisoa, Alain; Randrianasolo, Laurence; Tempia, Stefano; Guillebaud, Julia; Razanajatovo, Norosoa; Randriamampionona, Lea; Piola, Patrice; Halm, Ariane; Heraud, Jean-Michel

    2017-05-01

    Evaluation of influenza surveillance systems is poor, especially in Africa. In 2007, the Institut Pasteur de Madagascar and the Malagasy Ministry of Public Health implemented a countrywide system for the prospective syndromic and virological surveillance of influenza-like illnesses. In assessing this system's performance, we identified gaps and ways to promote the best use of resources. We investigated acceptability, data quality, flexibility, representativeness, simplicity, stability, timeliness and usefulness and developed qualitative and/or quantitative indicators for each of these attributes. Until 2007, the influenza surveillance system in Madagascar was only operational in Antananarivo and the observations made could not be extrapolated to the entire country. By 2014, the system covered 34 sentinel sites across the country. At 12 sites, nasopharyngeal and/or oropharyngeal samples were collected and tested for influenza virus. Between 2009 and 2014, 177 718 fever cases were detected, 25 809 (14.5%) of these fever cases were classified as cases of influenza-like illness. Of the 9192 samples from patients with influenza-like illness that were tested for influenza viruses, 3573 (38.9%) tested positive. Data quality for all evaluated indicators was categorized as above 90% and the system also appeared to be strong in terms of its acceptability, simplicity and stability. However, sample collection needed improvement. The influenza surveillance system in Madagascar performed well and provided reliable and timely data for public health interventions. Given its flexibility and overall moderate cost, this system may become a useful platform for syndromic and laboratory-based surveillance in other low-resource settings.

  4. Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testing.

    Science.gov (United States)

    Wesolowski, Laura G; MacKellar, Duncan A; Facente, Shelley N; Dowling, Teri; Ethridge, Steven F; Zhu, Julia H; Sullivan, Patrick S

    2006-08-01

    Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the

  5. Evaluation of health surveillance activities of hajj 2013 in the hajj embarkation Palangkaraya

    Directory of Open Access Journals (Sweden)

    Elvan Virgo Hoesea

    2014-05-01

    Full Text Available ABSTRACT Meningococcal meningitis and MERS-CoV is a disease that can be transmitted to a wary pilgrim considering the high incidence of both diseases in the Middle East region. This study was conducted to evaluate the surveillance activities conducted at embarkation Palangkaraya pilgrimage between 2013 and assess the surveillance activities based on the attributes of surveillance and barriers that occur in the implementation of activities. Experiment was conducted with descriptive design using quantitative approach. Questionnaires were completed at 6 implementing surveillance activities. Interviews were conducted to obtain information about the variables under study includes data collection, processing, analysis and interpretation, dissemination of information and surveillance attributes such as simplicity, flexibility, acceptability, sensitivity, positive predictive value, representatif, timeliness, data quality and data stability. Implementation health surveillance in the hajj embarkation Palangkaraya in 2013 showed all stages of the surveillance activities have been conducted in accordance with the procedures as well as evaluating surveillance activities in accordance attribute shows all the attributes of surveillance can be assessed, unless the sensitivity and positive predictive value because no cases of meningococcal meningitis. Conclusion that the implementation of health surveillance activities Hajj has been running quite well based approach to surveillance and surveillance attributes. The report has been used by the agency activities related to the activities of hajj embarkation. Need to increase the quantity and quality of manpower resources and facilities Keywords: disease transmission, hajj health surveillance, assessment                             attributes

  6. The 5th surveillance testing for Kori unit 1 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed primarily by Korea Atomic Energy Research Institute and Westinhouse corporation partially involved in testing and calculation data evaluation in order to obtain reliable test result. Fast neutron fluences for capsule V, T, S, R and P were 5.087E+18, 1.115E+19, 1.228E+19, 2.988E+19, and 3.938E+19n/cm2, respectively. The bias factor, the ratio of calculation/measurement, was 0.940 for the 1st through 5th testing and the calculational uncertainty, 7% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.9846E+19n/cm{sup 2} based on the end of 17th fuel cycle and it was predicted that the fluences of vessel inside surface at 24, 32, 40 and 48EFPY would reach 3.0593E+19, 4.0695E+19, 5.0797E+19 and 6.0900E+19n/cm{sup 2} based on the current calculation. PTS analysis for Kori unit 1 showed that 27.93EFPY was the threshold value for 300 deg F requirement. 71 refs., 33 figs., 52 tabs. (Author)

  7. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Sony Computer (Iby)

    HIV surveillance system generates information for timely and appropriate ..... active type of surveillance.14 Nonetheless, it requires training, supervision and motivation ... very effectively.14 The introduction of reward-system could be included.

  8. 2007 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-06-30

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  9. 2006 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2008-04-24

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of illness and injury surveillance activities that provide an early warning system to detect health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence, occupational injuries and illnesses, and disabilities and deaths among current workers.

  10. 2008 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-10-05

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  11. Perceptual evaluation of visual alerts in surveillance videos

    Science.gov (United States)

    Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun

    2015-03-01

    Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.

  12. Genotyping using whole-genome sequencing is a realistic alternative to surveillance based on phenotypic antimicrobial susceptibility testing

    DEFF Research Database (Denmark)

    Zankari, Ea; Hasman, Henrik; Kaas, Rolf Sommer

    2013-01-01

    -genome sequencing (WGS) may soon be within reach even for routine surveillance and clinical diagnostics. The aim of this study was to evaluate WGS as a routine tool for surveillance of antimicrobial resistance compared with current phenotypic procedures. Methods: Antimicrobial susceptibility tests were performed...... to the categorizing of isolates as resistant and 2569 as susceptible. Seven cases of disagreement between tested and predicted susceptibility were observed, six of which were related to spectinomycin resistance in Escherichia coli. Correlation between MLST type and resistance profiles was only observed in Salmonella...

  13. Final report : mobile surveillance and wireless communication systems field operational test. Volume 2, FOT objectives, organization, system design, results, conclusions, and recommendations

    Science.gov (United States)

    1999-03-01

    The Mobile Surveillance and Wireless Communication Systems Field Operational Test (FOT) evaluated the performance of wireless traffic detection and communications systems in areas where permanent detectors, electrical power, and landline communicatio...

  14. Evaluation of tuberculosis public health surveillance, Al-Madinah province, Kingdom of Saudi Arabia, 2012

    Directory of Open Access Journals (Sweden)

    Mohammed J. Alkhalawi

    2016-03-01

    Full Text Available The objective of the study is to evaluate the quality of the data, the sensitivity of the surveillance, and the completeness of identification and investigation of tuberculosis (TB patient’s contacts. The study covered the TB surveillance program in Al-Madinah province in 2011. First, we reviewed all the notifications, treatment cards, and register books, as well as monthly and quarterly reports, for completeness and accuracy of data. Then, we searched for the missed cases that were not reported. Finally, we reviewed all the patients’ household contacts’ reports to assess the degree of completion of identification and investigation. There were 444 cases detected during the study period; only 200 cases were reported. The sensitivity of the TB surveillance system was 45%. Among the 200 reported cases, the results revealed high completeness rates for demographic and disease data and low completeness rates for the test result fields. The contact identification and investigation showed that 34.4% of smear-positive cases’ contacts were not identified. Only 67% of identified contacts were investigated. The review of hospital records and lab registers showed that 244 cases were not reported. In conclusion, the TB surveillance system has several areas that need improvement.

  15. Detecting Ebola with limited laboratory access in the Democratic Republic of Congo: evaluation of a clinical passive surveillance reporting system.

    Science.gov (United States)

    Ashbaugh, Hayley R; Kuang, Brandon; Gadoth, Adva; Alfonso, Vivian H; Mukadi, Patrick; Doshi, Reena H; Hoff, Nicole A; Sinai, Cyrus; Mossoko, Mathias; Kebela, Benoit Ilunga; Muyembe, Jean-Jacques; Wemakoy, Emile Okitolonda; Rimoin, Anne W

    2017-09-01

    Ebola virus disease (EVD) can be clinically severe and highly fatal, making surveillance efforts for early disease detection of paramount importance. In areas with limited access to laboratory testing, the Integrated Disease Surveillance and Response (IDSR) strategy in the Democratic Republic of Congo (DRC) may be a vital tool in improving outbreak response. Using DRC IDSR data from the nation's four EVD outbreak periods from 2007-2014, we assessed trends of Viral Hemorrhagic Fever (VHF) and EVD differential diagnoses reportable through IDSR. With official case counts from active surveillance of EVD outbreaks, we assessed accuracy of reporting through the IDSR passive surveillance system. Although the active and passive surveillance represent distinct sets of data, the two were correlated, suggesting that passive surveillance based only on clinical evaluation may be a useful predictor of true cases prior to laboratory confirmation. There were 438 suspect VHF cases reported through the IDSR system and 416 EVD cases officially recorded across the outbreaks examined. Although collected prior to official active surveillance cases, case reporting through the IDSR during the 2007, 2008 and 2012 outbreaks coincided with official EVD epidemic curves. Additionally, all outbreak areas experienced increases in suspected cases for both malaria and typhoid fever during EVD outbreaks, underscoring the importance of training health care workers in recognising EVD differential diagnoses and the potential for co-morbidities. © 2017 John Wiley & Sons Ltd.

  16. Hantavirus pulmonary syndrome clinical findings: evaluating a surveillance case definition.

    Science.gov (United States)

    Knust, Barbara; Macneil, Adam; Rollin, Pierre E

    2012-05-01

    Clinical cases of hantavirus pulmonary syndrome (HPS) can be challenging to differentiate from other acute respiratory diseases, which can lead to delays in diagnosis, treatment, and disease reporting. Rapid onset of severe disease occurs, at times before diagnostic test results are available. This study's objective was to examine the clinical characteristics of patients that would indicate HPS to aid in detection and reporting. Test results of blood samples from U.S. patients suspected of having HPS submitted to the Centers for Disease Control and Prevention from 1998-2010 were reviewed. Patient information collected by case report forms was compared between HPS-confirmed and test-negative patients. Diagnostic sensitivity, specificity, predictive values, and likelihood ratios were calculated for individual clinical findings and combinations of variables. Of 567 patients included, 36% were HPS-confirmed. Thrombocytopenia, chest x-rays with suggestive signs, and receiving supplemental oxygenation were highly sensitive (>95%), while elevated hematocrit was highly specific (83%) in detecting HPS. Combinations that maximized sensitivity required the presence of thrombocytopenia. Using a national sample of suspect patients, we found that thrombocytopenia was a highly sensitive indicator of HPS and should be included in surveillance definitions for suspected HPS. Using a sensitive suspect case definition to identify potential HPS patients that are confirmed by highly specific diagnostic testing will ensure accurate reporting of this disease.

  17. Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment. Research project

    International Nuclear Information System (INIS)

    Martorell, S.; Serradell, V.; Munoz, A.; Sanchez, A.

    1997-01-01

    Background, objective, scope, detailed working plan and follow-up and final product of the project ''Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment'' are described

  18. The 4th surveillance testing for Kori unit 3 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-10-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 4.983E+18, 1.641E+19, 3.158E+19, and 4.469E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.840 for the 1st through 4th testing and the calculational uncertainty, 12% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.362E+19n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.481E+19, 4.209E+19, 5.144E+19 and 5.974E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 41 tabs. (Author)

  19. The 5th surveillance testing for Kori unit 2 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-03-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules V, R, P, T and N are 2.837E+18, 1.105E+19, 2.110E+19, 3.705E+19 and 4.831E+19n/cm{sup 2}, respectively. The bias factor, the ratio of measurement/calculation, was 0.918 for the 1st through 5th testing and the calculational uncertainty, 11.6% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.898E+19n/cm{sup 2} based on the end of 15th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 4.203E+19, 5.232E+19, 6.262E+19 and 7.291E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 49 refs., 35 figs., 48 tabs. (Author)

  20. An evaluation of the Australian Rotavirus Surveillance Program.

    Science.gov (United States)

    Roberts-Witteveen, April R; Patel, Mahomed S; Roche, Paul W

    2008-09-01

    The Australian Rotavirus Serotyping Program (ARSP) serotypes rotavirus isolates obtained from stool samples sent from Australian laboratories. In collaboration with ARSP the Australian Government Department of Health and Ageing evaluated the program for its utility and capacity to monitor effectiveness of the rotavirus vaccines recently introduced into the Australian National Immunisation Program. The system was described using ARSP annual reports and staff interviews. The attributes of the system were assessed by adapting standard guidelines for evaluating a surveillance system. Email surveys or face to face interviews were conducted with staff of ARSP, participating laboratories, rotavirus vaccine manufacturing companies and representatives of the Communicable Diseases Network Australia. The ability of the ARSP to monitor changes in rotavirus serotype epidemiology was assessed. ARSP serotypes rotavirus isolates received from participating laboratories at least bi-annually, with results being reported at least as often. Serotype analyses have informed formulation of rotavirus vaccines and contributed to forecasting the extent of outbreaks caused by novel serotypes. The ARSP will be able to monitor changes in rotavirus serotype epidemiology and identify probable vaccination failures. Enhancement of the representativeness and sensitivity of the system are needed for the data to remain useful in the public health context. Methods for transferring data between the program and state and territory health departments need to be developed.

  1. Proficiency tests, Evaluating

    NARCIS (Netherlands)

    Cofino, W.P.; Molenaar, J.; Torfs, P.J.J.F.

    2017-01-01

    Marine monitoring programs provide data that are essential for marine management. The reliability of such data is underpinned by proficiency tests. In the context of Quasimeme, a proficiency testing program for the marine environment, a statistical model has been developed in 2000 to evaluate data

  2. Hot cell examination on the surveillance capsule of SA 533 cl. 1 reactor pressure vessel (1st test report)

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yong Sun; Jung, Y. H.; Yoo, B. O.; Baik, S. J.; Oh, W. H.; Soong, W. S.; Hong, K. P

    2000-08-01

    The post-irradiated examinations such as impact test, tensile test, composition analysis and etc. were conducted to monitor and to evaluate the radiation-induced changes, so called radiation embrittlement, in the mechanical properties of ferritic materials. Those data should be applied to confirm safety as well as reliability of reactor pressure vessel. The scopes and contents of hot cell examination on the surveillance capsule are as follows; - Capsule transportation, cutting, dismantling and classification - Shim block and Dosimeter cutting and dismantling - Impact test - Tensile test - Composition analysis by EPMA - SEM observation on the fractured surface - Hardness test - Radwaste treatment.

  3. Evaluation of a serological Salmonella Mix-ELISA for poultry used in a national surveillance programme

    DEFF Research Database (Denmark)

    Feld, Niels Christian; Ekeroth, Lars; Gradel, K.O.

    2000-01-01

    by Mix-ELISA and by faecal culture, and in case of a positive result in either of these a repeated, serological testing was performed, and 60 animals were organ-cultured. If one of these samplings was positive, the flock was declared salmonella infected. In a period of 3 months, 35 flocks were found......A Mix-ELISA using lipopolysaccharide antigens from Salmonella enterica serotype Enteritidis and Typhimurium? was evaluated using samples collected over time in the Danish salmonella surveillance programme for poultry. Serological samples (n = 42813) taken from broiler-breeder flocks after a year...

  4. Evaluation of the cost-effectiveness of bovine brucellosis surveillance in a disease-free country using stochastic scenario tree modelling.

    Science.gov (United States)

    Hénaux, Viviane; Calavas, Didier

    2017-01-01

    Surveillance systems of exotic infectious diseases aim to ensure transparency about the country-specific animal disease situation (i.e. demonstrate disease freedom) and to identify any introductions. In a context of decreasing resources, evaluation of surveillance efficiency is essential to help stakeholders make relevant decisions about prioritization of measures and funding allocation. This study evaluated the efficiency (sensitivity related to cost) of the French bovine brucellosis surveillance system using stochastic scenario tree models. Cattle herds were categorized into three risk groups based on the annual number of purchases, given that trading is considered as the main route of brucellosis introduction in cattle herds. The sensitivity in detecting the disease and the costs of the current surveillance system, which includes clinical (abortion) surveillance, programmed serological testing and introduction controls, were compared to those of 19 alternative surveillance scenarios. Surveillance costs included veterinary fees and laboratory analyses. The sensitivity over a year of the current surveillance system was predicted to be 91±7% at a design prevalence of 0.01% for a total cost of 14.9±1.8 million €. Several alternative surveillance scenarios, based on clinical surveillance and random or risk-based serological screening in a sample (20%) of the population, were predicted to be at least as sensitive but for a lower cost. Such changes would reduce whole surveillance costs by 20 to 61% annually, and the costs for farmers only would be decreased from about 12.0 million € presently to 5.3-9.0 million € (i.e. 25-56% decrease). Besides, fostering the evolution of the surveillance system in one of these directions would be in agreement with the European regulations and farmers perceptions on brucellosis risk and surveillance.

  5. Evaluation of the cost-effectiveness of bovine brucellosis surveillance in a disease-free country using stochastic scenario tree modelling.

    Directory of Open Access Journals (Sweden)

    Viviane Hénaux

    Full Text Available Surveillance systems of exotic infectious diseases aim to ensure transparency about the country-specific animal disease situation (i.e. demonstrate disease freedom and to identify any introductions. In a context of decreasing resources, evaluation of surveillance efficiency is essential to help stakeholders make relevant decisions about prioritization of measures and funding allocation. This study evaluated the efficiency (sensitivity related to cost of the French bovine brucellosis surveillance system using stochastic scenario tree models. Cattle herds were categorized into three risk groups based on the annual number of purchases, given that trading is considered as the main route of brucellosis introduction in cattle herds. The sensitivity in detecting the disease and the costs of the current surveillance system, which includes clinical (abortion surveillance, programmed serological testing and introduction controls, were compared to those of 19 alternative surveillance scenarios. Surveillance costs included veterinary fees and laboratory analyses. The sensitivity over a year of the current surveillance system was predicted to be 91±7% at a design prevalence of 0.01% for a total cost of 14.9±1.8 million €. Several alternative surveillance scenarios, based on clinical surveillance and random or risk-based serological screening in a sample (20% of the population, were predicted to be at least as sensitive but for a lower cost. Such changes would reduce whole surveillance costs by 20 to 61% annually, and the costs for farmers only would be decreased from about 12.0 million € presently to 5.3-9.0 million € (i.e. 25-56% decrease. Besides, fostering the evolution of the surveillance system in one of these directions would be in agreement with the European regulations and farmers perceptions on brucellosis risk and surveillance.

  6. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  7. SERVAL: a new framework for the evaluation of animal health surveillance.

    Science.gov (United States)

    Drewe, J A; Hoinville, L J; Cook, A J C; Floyd, T; Gunn, G; Stärk, K D C

    2015-02-01

    Animal health surveillance programmes may change in response to altering requirements or perceived weaknesses but are seldom subjected to any formal evaluation to ensure that they provide valuable information in an efficient manner. The literature on the evaluation of animal health surveillance systems is sparse, and those that are published may be unstructured and therefore incomplete. To address this gap, we have developed SERVAL, a SuRveillance EVALuation framework, which is novel and aims to be generic and therefore suitable for the evaluation of any animal health surveillance system. The inclusion of socio-economic criteria ensures that economic evaluation is an integral part of this framework. SERVAL was developed with input from a technical workshop of international experts followed by a consultation process involving providers and users of surveillance and evaluation data. It has been applied to a range of case studies encompassing different surveillance and evaluation objectives. Here, we describe the development, structure and application of the SERVAL framework. We discuss users' experiences in applying SERVAL to evaluate animal health surveillance systems in Great Britain. © 2013 Crown Copyright. This article is published with the permission of the Controller of HMSO and the Queen's Printer for Scotland.

  8. Reliability of case definitions for public health surveillance assessed by Round-Robin test methodology

    Directory of Open Access Journals (Sweden)

    Claus Hermann

    2006-05-01

    Full Text Available Abstract Background Case definitions have been recognized to be important elements of public health surveillance systems. They are to assure comparability and consistency of surveillance data and have crucial impact on the sensitivity and the positive predictive value of a surveillance system. The reliability of case definitions has rarely been investigated systematically. Methods We conducted a Round-Robin test by asking all 425 local health departments (LHD and the 16 state health departments (SHD in Germany to classify a selection of 68 case examples using case definitions. By multivariate analysis we investigated factors linked to classification agreement with a gold standard, which was defined by an expert panel. Results A total of 7870 classifications were done by 396 LHD (93% and all SHD. Reporting sensitivity was 90.0%, positive predictive value 76.6%. Polio case examples had the lowest reporting precision, salmonellosis case examples the highest (OR = 0.008; CI: 0.005–0.013. Case definitions with a check-list format of clinical criteria resulted in higher reporting precision than case definitions with a narrative description (OR = 3.08; CI: 2.47–3.83. Reporting precision was higher among SHD compared to LHD (OR = 1.52; CI: 1.14–2.02. Conclusion Our findings led to a systematic revision of the German case definitions and build the basis for general recommendations for the creation of case definitions. These include, among others, that testable yes/no criteria in a check-list format is likely to improve reliability, and that software used for data transmission should be designed in strict accordance with the case definitions. The findings of this study are largely applicable to case definitions in many other countries or international networks as they share the same structural and editorial characteristics of the case definitions evaluated in this study before their revision.

  9. Standard evaluation techniques for containment and surveillance radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1982-01-01

    Evaluation techniques used at Los Alamos for personnel and vehicle radiation monitors that safeguard nuclear material determine the worst-case sensitivity. An evaluation tests a monitor's lowest sensitivity regions with sources that have minimum emission rates. The result of our performance tests are analyzed as a binomial experiment. The number of trials that are required to verify the monitor's probability of detection is determined by a graph derived from the confidence limits for a binomial distribution. Our testing results are reported in a way that characterizes the monitor yet does not compromise security by revealing its routine performance for detecting process materials

  10. Boraflex test results and evaluation

    International Nuclear Information System (INIS)

    Lindquist, K.; Kline, D.E.; Haley, T.C.

    1993-02-01

    New data developed, collected, and evaluated to further assess the in-pool performance of the neutron absorber material, Boraflex. The data are from new EPRI test programs, utility surveillance programs, and blackness testing at a number of plants. This new data provides a basis for quantifying the gap phenomenon in full length panels of Boraflex in spent fuel racks; the maximum anticipated gap size, frequency of gap occurrence, and axial distribution of gaps. Methods have been developed to assess the reactivity effects of gaps and Boraflex shrinkage. The analyses presented demonstrates that the reactivity effect of gaps is very small, not much larger than the statistical variations inherent in the calculational method. The data and analyses presented serve to close the issue of gap formation and shrinkage in panels of Boraflex and the effect of such gaps and shrinkage on the reactivity of the fuel/rack configuration. Ongoing EPRI programs to assess the long term performance of Boraflex in spent fuel storage racks are described

  11. A methodological framework for the evaluation of syndromic surveillance systems: a case study of England.

    Science.gov (United States)

    Colón-González, Felipe J; Lake, Iain R; Morbey, Roger A; Elliot, Alex J; Pebody, Richard; Smith, Gillian E

    2018-04-24

    Syndromic surveillance complements traditional public health surveillance by collecting and analysing health indicators in near real time. The rationale of syndromic surveillance is that it may detect health threats faster than traditional surveillance systems permitting more timely, and hence potentially more effective public health action. The effectiveness of syndromic surveillance largely relies on the methods used to detect aberrations. Very few studies have evaluated the performance of syndromic surveillance systems and consequently little is known about the types of events that such systems can and cannot detect. We introduce a framework for the evaluation of syndromic surveillance systems that can be used in any setting based upon the use of simulated scenarios. For a range of scenarios this allows the time and probability of detection to be determined and uncertainty is fully incorporated. In addition, we demonstrate how such a framework can model the benefits of increases in the number of centres reporting syndromic data and also determine the minimum size of outbreaks that can or cannot be detected. Here, we demonstrate its utility using simulations of national influenza outbreaks and localised outbreaks of cryptosporidiosis. Influenza outbreaks are consistently detected with larger outbreaks being detected in a more timely manner. Small cryptosporidiosis outbreaks (framework constitutes a useful tool for public health emergency preparedness in multiple settings. The proposed framework allows the exhaustive evaluation of any syndromic surveillance system and constitutes a useful tool for emergency preparedness and response.

  12. Targeted surveillance for postnatal hearing loss: a program evaluation.

    Science.gov (United States)

    Beswick, Rachael; Driscoll, Carlie; Kei, Joseph; Glennon, Shirley

    2012-07-01

    The importance of monitoring hearing throughout early childhood cannot be understated. However, there is a lack of evidence available regarding the most effective method of monitoring hearing following the newborn screen. The goal of this study was to describe a targeted surveillance program using a risk factor registry to identify children with a postnatal hearing loss. All children who were born in Queensland, Australia between September 2004 and December 2009, received a bilateral 'pass' on newborn hearing screening, and had at least one risk factor, were referred for targeted surveillance and were included in this study. The cohort was assessed throughout early childhood in accordance with Queensland's diagnostic assessment protocols. During the study period, 7320 (2.8% of 261,328) children were referred for targeted surveillance, of which 56 were identified with a postnatal hearing loss (0.77%). Of these, half (50.0%) were identified with a mild hearing loss, and 64.3% were identified with a sensorineural hearing loss. In regards to risk factors, syndrome, craniofacial anomalies, and severe asphyxia had the highest yield of positive cases of postnatal hearing loss for children referred for targeted surveillance, whereas, low birth weight, bacterial meningitis, and professional concern had a particularly low yield. Limitations of the targeted surveillance program were noted and include: (1) a lost contact rate of 32.4%; (2) delays in first surveillance assessment; (3) a large number of children who required on-going monitoring; and (4) extensive diagnostic assessments were completed on children with normal hearing. Examination of the lost contact rate revealed indigenous children were more likely to be documented as lost contact. In addition, children with one risk factor only were significantly more likely to not attend a surveillance appointment. Positive cases of postnatal hearing loss were detected through the targeted surveillance program. However, the

  13. Evaluation of the Effectiveness and Cost-Effectiveness of Personalized Surveillance After Colorectal Adenomatous Polypectomy.

    Science.gov (United States)

    McFerran, Ethna; O'Mahony, James F; Fallis, Richard; McVicar, Duncan; Zauber, Ann G; Kee, Frank

    2017-01-01

    Lifetime risk of developing colorectal cancer is 5%, and 5-year survival at early stage is 92%. Individuals with precancerous lesions removed at primary screening are typically recommended surveillance colonoscopy. Because greater benefits are anticipated for those with higher risk of colorectal cancer, scope for risk-specific surveillance recommendations exists. This review assesses published cost-effectiveness estimates of postpolypectomy surveillance to consider the potential for personalized recommendations by risk group. Meta-analyses of incidence of advanced neoplasia postpolypectomy for low-risk cases were comparable to those without adenoma, with both rates under the lifetime risk of 5%. This group may not benefit from intensive surveillance, which risks unnecessary harm and inefficient use of often scarce colonoscopy capacity. Therefore, greater personalization through deintensified strategies for low-risk individuals could be beneficial. The potential for noninvasive testing, such as fecal immunochemical tests, combined with primary prevention or chemoprevention may reserve colonoscopy for targeted use in personalized risk-stratified surveillance. This review appraised evidence supporting a program of personalized surveillance in patients with colorectal adenoma according to risk group and compared the effectiveness of surveillance colonoscopy with alternative prevention strategies. It assessed trade-offs among costs, benefits, and adverse effects that must be considered in a decision to adopt or reject personalized surveillance. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Conditional dependence between tests affects the diagnosis and surveillance of animal diseases

    DEFF Research Database (Denmark)

    Gardner, I.A.; Stryhn, Henrik; Lind, Peter

    2000-01-01

    Dependence between the sensitivities or specificities of pairs of tests affects the sensitivity and specificity of tests when used in combination. Compared with values expected if tests are conditionally independent, a positive dependence in test sensitivity reduces the sensitivity of parallel te...... for toxoplasmosis and brucellosis in swine, and Johne's disease in cattle to illustrate calculation methods and to indicate the likely magnitude of the dependence between serologic tests used for diagnosis and surveillance of animal diseases....

  15. Evaluation of outbreak detection performance using multi-stream syndromic surveillance for influenza-like illness in rural Hubei Province, China: a temporal simulation model based on healthcare-seeking behaviors.

    Directory of Open Access Journals (Sweden)

    Yunzhou Fan

    Full Text Available BACKGROUND: Syndromic surveillance promotes the early detection of diseases outbreaks. Although syndromic surveillance has increased in developing countries, performance on outbreak detection, particularly in cases of multi-stream surveillance, has scarcely been evaluated in rural areas. OBJECTIVE: This study introduces a temporal simulation model based on healthcare-seeking behaviors to evaluate the performance of multi-stream syndromic surveillance for influenza-like illness. METHODS: Data were obtained in six towns of rural Hubei Province, China, from April 2012 to June 2013. A Susceptible-Exposed-Infectious-Recovered model generated 27 scenarios of simulated influenza A (H1N1 outbreaks, which were converted into corresponding simulated syndromic datasets through the healthcare-behaviors model. We then superimposed converted syndromic datasets onto the baselines obtained to create the testing datasets. Outbreak performance of single-stream surveillance of clinic visit, frequency of over the counter drug purchases, school absenteeism, and multi-stream surveillance of their combinations were evaluated using receiver operating characteristic curves and activity monitoring operation curves. RESULTS: In the six towns examined, clinic visit surveillance and school absenteeism surveillance exhibited superior performances of outbreak detection than over the counter drug purchase frequency surveillance; the performance of multi-stream surveillance was preferable to signal-stream surveillance, particularly at low specificity (Sp <90%. CONCLUSIONS: The temporal simulation model based on healthcare-seeking behaviors offers an accessible method for evaluating the performance of multi-stream surveillance.

  16. A conceptual framework for the evaluation of HLB surveillance activities.

    Science.gov (United States)

    Surveillance activities play an integral part in disease prevention and control, and underpin the three main stages of disease mitigation: the prevention of entry and establishment of exotic pathogens; the detailed investigation of more established pathogens; and the monitoring of disease control me...

  17. SurF: an innovative framework in biosecurity and animal health surveillance evaluation.

    Science.gov (United States)

    Muellner, Petra; Watts, Jonathan; Bingham, Paul; Bullians, Mark; Gould, Brendan; Pande, Anjali; Riding, Tim; Stevens, Paul; Vink, Daan; Stärk, Katharina Dc

    2018-05-16

    Surveillance for biosecurity hazards is being conducted by the New Zealand Competent Authority, the Ministry for Primary Industries (MPI) to support New Zealand's biosecurity system. Surveillance evaluation should be an integral part of the surveillance life cycle, as it provides a means to identify and correct problems and to sustain and enhance the existing strengths of a surveillance system. The surveillance evaluation Framework (SurF) presented here was developed to provide a generic framework within which the MPI biosecurity surveillance portfolio, and all of its components, can be consistently assessed. SurF is an innovative, cross-sectoral effort that aims to provide a common umbrella for surveillance evaluation in the animal, plant, environment and aquatic sectors. It supports the conduct of the following four distinct components of an evaluation project: (i) motivation for the evaluation, (ii) scope of the evaluation, (iii) evaluation design and implementation and (iv) reporting and communication of evaluation outputs. Case studies, prepared by MPI subject matter experts, are included in the framework to guide users in their assessment. Three case studies were used in the development of SurF in order to assure practical utility and to confirm usability of SurF across all included sectors. It is anticipated that the structured approach and information provided by SurF will not only be of benefit to MPI but also to other New Zealand stakeholders. Although SurF was developed for internal use by MPI, it could be applied to any surveillance system in New Zealand or elsewhere. © 2018 2018 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  18. Evaluation of outbreak detection performance using multi-stream syndromic surveillance for influenza-like illness in rural Hubei Province, China: a temporal simulation model based on healthcare-seeking behaviors.

    Science.gov (United States)

    Fan, Yunzhou; Wang, Ying; Jiang, Hongbo; Yang, Wenwen; Yu, Miao; Yan, Weirong; Diwan, Vinod K; Xu, Biao; Dong, Hengjin; Palm, Lars; Nie, Shaofa

    2014-01-01

    Syndromic surveillance promotes the early detection of diseases outbreaks. Although syndromic surveillance has increased in developing countries, performance on outbreak detection, particularly in cases of multi-stream surveillance, has scarcely been evaluated in rural areas. This study introduces a temporal simulation model based on healthcare-seeking behaviors to evaluate the performance of multi-stream syndromic surveillance for influenza-like illness. Data were obtained in six towns of rural Hubei Province, China, from April 2012 to June 2013. A Susceptible-Exposed-Infectious-Recovered model generated 27 scenarios of simulated influenza A (H1N1) outbreaks, which were converted into corresponding simulated syndromic datasets through the healthcare-behaviors model. We then superimposed converted syndromic datasets onto the baselines obtained to create the testing datasets. Outbreak performance of single-stream surveillance of clinic visit, frequency of over the counter drug purchases, school absenteeism, and multi-stream surveillance of their combinations were evaluated using receiver operating characteristic curves and activity monitoring operation curves. In the six towns examined, clinic visit surveillance and school absenteeism surveillance exhibited superior performances of outbreak detection than over the counter drug purchase frequency surveillance; the performance of multi-stream surveillance was preferable to signal-stream surveillance, particularly at low specificity (Sp performance of multi-stream surveillance.

  19. Exploring the Benefits of Molecular Testing for Gonorrhoea Antibiotic Resistance Surveillance in Remote Settings.

    Directory of Open Access Journals (Sweden)

    Ben B Hui

    Full Text Available Surveillance for gonorrhoea antimicrobial resistance (AMR is compromised by a move away from culture-based testing in favour of more convenient nucleic acid amplification test (NAAT tests. We assessed the potential benefit of a molecular resistance test in terms of the timeliness of detection of gonorrhoea AMR.An individual-based mathematical model was developed to describe the transmission of gonorrhoea in a remote Indigenous population in Australia. We estimated the impact of the molecular test on the time delay between first importation and the first confirmation that the prevalence of gonorrhoea AMR (resistance proportion has breached the WHO-recommended 5% threshold (when a change in antibiotic should occur. In the remote setting evaluated in this study, the model predicts that when culture is the only available means of testing for AMR, the breach will only be detected when the actual prevalence of AMR in the population has already reached 8 - 18%, with an associated delay of ~43 - 69 months between first importation and detection. With the addition of a molecular resistance test, the number of samples for which AMR can be determined increases facilitating earlier detection at a lower resistance proportion. For the best case scenario, where AMR can be determined for all diagnostic samples, the alert would be triggered at least 8 months earlier than using culture alone and the resistance proportion will have only slightly exceeded the 5% notification threshold.Molecular tests have the potential to provide more timely warning of the emergence of gonorrhoea AMR. This in turn will facilitate earlier treatment switching and more targeted treatment, which has the potential to reduce the population impact of gonorrhoea AMR.

  20. Exploring the Benefits of Molecular Testing for Gonorrhoea Antibiotic Resistance Surveillance in Remote Settings.

    Science.gov (United States)

    Hui, Ben B; Ryder, Nathan; Su, Jiunn-Yih; Ward, James; Chen, Marcus Y; Donovan, Basil; Fairley, Christopher K; Guy, Rebecca J; Lahra, Monica M; Law, Mathew G; Whiley, David M; Regan, David G

    2015-01-01

    Surveillance for gonorrhoea antimicrobial resistance (AMR) is compromised by a move away from culture-based testing in favour of more convenient nucleic acid amplification test (NAAT) tests. We assessed the potential benefit of a molecular resistance test in terms of the timeliness of detection of gonorrhoea AMR. An individual-based mathematical model was developed to describe the transmission of gonorrhoea in a remote Indigenous population in Australia. We estimated the impact of the molecular test on the time delay between first importation and the first confirmation that the prevalence of gonorrhoea AMR (resistance proportion) has breached the WHO-recommended 5% threshold (when a change in antibiotic should occur). In the remote setting evaluated in this study, the model predicts that when culture is the only available means of testing for AMR, the breach will only be detected when the actual prevalence of AMR in the population has already reached 8 - 18%, with an associated delay of ~43 - 69 months between first importation and detection. With the addition of a molecular resistance test, the number of samples for which AMR can be determined increases facilitating earlier detection at a lower resistance proportion. For the best case scenario, where AMR can be determined for all diagnostic samples, the alert would be triggered at least 8 months earlier than using culture alone and the resistance proportion will have only slightly exceeded the 5% notification threshold. Molecular tests have the potential to provide more timely warning of the emergence of gonorrhoea AMR. This in turn will facilitate earlier treatment switching and more targeted treatment, which has the potential to reduce the population impact of gonorrhoea AMR.

  1. Standard Guide for Conducting Supplemental Surveillance Tests for Nuclear Power Reactor Vessels, E 706 (IH)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide discusses test procedures that can be used in conjunction with, but not as alternatives to, those required by Practices E185 and E2215 for the surveillance of nuclear reactor vessels. The supplemental mechanical property tests outlined permit the acquisition of additional information on radiation-induced changes in fracture toughness, notch ductility, and yield strength properties of the reactor vessel steels. 1.2 This guide provides recommendations for the preparation of test specimens for irradiation, and identifies special precautions and requirements for reactor surveillance operations and postirradiation test planning. Guidance on data reduction and computational procedures is also given. Reference is made to other ASTM test methods for the physical conduct of specimen tests and for raw data acquisition.

  2. Evaluation of an Electronic Smart-Card Based School Absenteeism Surveillance System

    OpenAIRE

    So, HC; Lam, CK; Tam, YH; Cowling, BJ; Leung, GM; Lau, EHY; Ip, DKM

    2014-01-01

    We evaluated the performance of an electronic smart-card based school absenteeism surveillance system which was initiated in 2008 in Hong Kong. The result demonstrated the feasibility and potential benefit of employing electronic school absenteeism data as captured automatically by a smart card system as an alternative data stream for monitoring influenza activities, and flexibility in establishing surveillance for emerging diseases. The increasing popularity of usage of smart card technology...

  3. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance

    NARCIS (Netherlands)

    Murphy, S.C.; Hermsen, C.C.; Douglas, A.D.; Edwards, N.J.; Petersen, I.; Fahle, G.A.; Adams, M.; Berry, A.A.; Billman, Z.P.; Gilbert, S.C.; Laurens, M.B.; Leroy, O.; Lyke, K.E.; Plowe, C.V.; Seilie, A.M.; Strauss, K.A.; Teelen, K.; Hill, A.V.; Sauerwein, R.W.

    2014-01-01

    Nucleic acid testing (NAT) for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal

  4. The installation and performance test of the surveillance system for DUPIC facility

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system

  5. Integration of HIV testing in tuberculosis drug resistance surveillance in Kazakhstan and Kenya

    NARCIS (Netherlands)

    Klinkenberg, E.; van den Hof, S.; Tursynbayeva, A.; Kipruto, H.; Wahogo, J.; Pak, S.; Kutwa, A.; L'Herminez, R.

    2012-01-01

    In Kenya and Kazakhstan, integration of human immunodeficiency virus (HIV) testing results into the routine surveillance of multidrug-resistant tuberculosis (MDR-TB) proved feasible and useful. The integration process improved overall data quality and data validation capacity, and integrated data

  6. The installation and performance test of the surveillance system for DUPIC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system.

  7. Testing a symptom-based surveillance system at high-profile gatherings as a preparatory measure for bioterrorism.

    Science.gov (United States)

    Osaka, K; Takahashi, H; Ohyama, T

    2002-12-01

    We tested symptom-based surveillance during the G8 conference in 2000 as a means of detecting outbreaks, including bio-terrorism attacks, promptly. Five categories of symptoms (skin and haemorrhagic, respiratory, gastrointestinal, neurological and unexplained) were adopted for the case definition of the surveillance. The surveillance began I week before the conference, and continued until 1 week after the conference ended. We could not detect any outbreaks during this surveillance. Compared to the existing diagnosis-based surveillance system, symptom-based surveillance has the advantages of timeliness and simplicity. However, poor specificity and difficulties in determining epidemic threshold were important limitations of this system. To increase the specificity of surveillance, it is essential to incorporate rapid laboratory diagnoses into the system.

  8. Evaluation of self-swabbing coupled with a telephone health helpline as an adjunct tool for surveillance of influenza viruses in Ontario

    Directory of Open Access Journals (Sweden)

    D. McGolrick

    2016-09-01

    Full Text Available Abstract Background Calls to a telephone health helpline (THHL have been previously evaluated for the ability to monitor specific syndromes, such as fever and influenza-like-illness or gastrointestinal illness. This method of surveillance has been shown to be highly correlated with traditional surveillance methods, and to have potential for early detection of community-based illness. Self-sampling, or having a person take his/her own nasal swab, has also proven successful as a useful method for obtaining a specimen, which may be used for respiratory virus detection. Methods This study describes a self-swabbing surveillance system mediated by a nurse-led THHL in Ontario whereby syndromic surveillance concepts are used to recruit and monitor participants with influenza-like illness. Once recruited, participants collect a nasal specimen obtained by self-swabbing and submit for testing and laboratory confirmation. Enumeration of weekly case counts was used to evaluate the timeliness of the self-swabbing surveillance system through comparison to other respiratory virus and influenza surveillance systems in Ontario. The operational efficiency of the system was also evaluated. Results The mean and median number of days between the day that a participant called the THHL, to the day a package was received at the laboratory for testing were approximately 10.4 and 8.6 days, respectively. The time between self-swab collection and package reception was 4.9 days on average, with a median of 4 days. The self-swabbing surveillance system adequately captured the 2014 influenza B season in a timely manner when compared to other Ontario-based sources of influenza surveillance data from the same year; however, the emergence of influenza B was not detected any earlier than with these other surveillance systems. Influenza A surveillance was also evaluated. Using the THHL self-swabbing system, a peak in the number of cases for influenza A was observed approximately

  9. Automated reactivity anomaly surveillance in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.; Honeyman, D.J.; Shook, A.T.; Krohn, C.N.

    1985-01-01

    The automated technique for monitoring core reactivity during power operation used at the Fast Flux Test Facility (FFTF) is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. It is implemented on the Plant Data System (PDS) computer and, thus, provides rapid indication of any abnormal core conditions. The prediction algorithms use thermal-hydraulic, control rod position and neutron flux sensor information to predict the core reactivity state

  10. Estimation of RPV material embrittlement for Ukrainian NPP based on surveillance test data

    International Nuclear Information System (INIS)

    Revka, V.; Chyrko, L.; Chaikovsky, Yu.; Gulchuk, Yu.

    2012-01-01

    The WWER-1000 RPV material embrittlement has been evaluated using the surveillance test data for the nuclear power plant which is under operation in Ukraine. The RPV materials after the neutron (E > 0,5 MeV) irradiation up to fluence of 22,9.10 22 m -2 have been studied. Fracture toughness tests were performed using pre-cracked Charpy specimens for the beltline materials (base and weld metal). The maximum shift of T 0 reference temperature is equal to 44 o C. A radiation embrittlement rate, A F , for the RPV materials was estimated using the standard and reconstituted specimens. A comparison of the A F values has shown a good agreement between the specimen sets before and after reconstitution both for base and weld metal. Furthermore it has been revealed there is no nickel effect for the studied materials. In spite of the high nickel content the radiation embrittlement rate for weld metal is not higher than for base metal with low nickel content. Fracture toughness analysis has shown the Master curve shape describes well a temperature dependence of K Jc values. However a higher scatter of K Jc values is observed in comparison to 95 % tolerance bounds. (author)

  11. Improving national surveillance of Lyme neuroborreliosis in Denmark through electronic reporting of specific antibody index testing from 2010 to 2012

    DEFF Research Database (Denmark)

    Dessau, Ram Benny; Espenhain, L; Mølbak, K

    2015-01-01

    Our aim was to evaluate the results of automated surveillance of Lyme neuroborreliosis (LNB) in Denmark using the national microbiology database (MiBa), and to describe the epidemiology of laboratory-confirmed LNB at a national level. MiBa-based surveillance includes electronic transfer of labora......Our aim was to evaluate the results of automated surveillance of Lyme neuroborreliosis (LNB) in Denmark using the national microbiology database (MiBa), and to describe the epidemiology of laboratory-confirmed LNB at a national level. MiBa-based surveillance includes electronic transfer...

  12. Evaluation of Syndromic Surveillance Systems in 6 US State and Local Health Departments.

    Science.gov (United States)

    Thomas, Mathew J; Yoon, Paula W; Collins, James M; Davidson, Arthur J; Mac Kenzie, William R

    Evaluating public health surveillance systems is critical to ensuring that conditions of public health importance are appropriately monitored. Our objectives were to qualitatively evaluate 6 state and local health departments that were early adopters of syndromic surveillance in order to (1) understand the characteristics and current uses, (2) identify the most and least useful syndromes to monitor, (3) gauge the utility for early warning and outbreak detection, and (4) assess how syndromic surveillance impacted their daily decision making. We adapted evaluation guidelines from the Centers for Disease Control and Prevention and gathered input from the Centers for Disease Control and Prevention subject matter experts in public health surveillance to develop a questionnaire. We interviewed staff members from a convenience sample of 6 local and state health departments with syndromic surveillance programs that had been in operation for more than 10 years. Three of the 6 interviewees provided an example of using syndromic surveillance to identify an outbreak (ie, cluster of foodborne illness in 1 jurisdiction) or detect a surge in cases for seasonal conditions (eg, influenza in 2 jurisdictions) prior to traditional, disease-specific systems. Although all interviewees noted that syndromic surveillance has not been routinely useful or efficient for early outbreak detection or case finding in their jurisdictions, all agreed that the information can be used to improve their understanding of dynamic disease control environments and conditions (eg, situational awareness) in their communities. In the jurisdictions studied, syndromic surveillance may be useful for monitoring the spread and intensity of large outbreaks of disease, especially influenza; enhancing public health awareness of mass gatherings and natural disasters; and assessing new, otherwise unmonitored conditions when real-time alternatives are unavailable. Future studies should explore opportunities to

  13. Surveillance tests for light-water cooled nuclear power reactor vessels in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong-Sun; Ahn, Sang-Bok; Park, Dae-Gyu; Jung, Yang-Hong; Yoo, Byung-Ok; Oh, Wan-Ho; Baik, Seung-Je; Koo, Dae-Seo; Lee, Key-Soon

    1999-01-01

    The surveillance tests for light-water cooled nuclear power reactor vessels were established to monitor the radiation-induced changes in the mechanical properties of ferritic materials in the beltline according to US NRC 10 CFR 50 App. G, US NRC RG1.99-rev.2, ASTM E185-82 and E185-94 in Irradiated Materials Examination Facility(IMEF). The surveillance capsule was transported from NPPs pool sites to KAERI IMEF by using a shipping cask. The capsule was cut and dismantled by capsule cutting machine and milling machine in M2 hot cell. Charpy tests and tension tests were performed in M5a and M5b hot cells respectively. Especially the EPMA located at hot lab was used to analyze the Ni and Cu wt% composition of base metal and weld for predicting the adjusted reference temperature(ART). The established process and test results were summarized in this paper. (author)

  14. Evaluating surveillance indicators supporting the Global Polio Eradication Initiative, 2011-2012.

    Science.gov (United States)

    2013-04-12

    The Global Polio Eradication Initiative (GPEI) was established in 1988 by the World Health Assembly to interrupt transmission of wild poliovirus (WPV); completion of this initiative was declared a programmatic emergency of public health in January 2012. Polio cases are detected through surveillance for acute flaccid paralysis (AFP) with linked stool specimens tested for polioviruses (PVs) at accredited laboratories within the Global Polio Laboratory Network (GPLN). AFP surveillance findings are supplemented by testing sewage samples (environmental surveillance) collected at selected sites. Virologic data guide where targeted immunization activities should be conducted or improved. Key performance indicators are used to 1) monitor AFP surveillance quality at national and subnational levels to identify gaps where PV transmission could occur undetected; 2) provide evidence of where PV circulation has been interrupted; and 3) allow timely detection of an outbreak. Standardized surveillance indicators allow progress to be monitored over time and compared among countries. This report presents AFP surveillance performance indicators at national and subnational levels for countries affected by polio during 2011-2012, and trends in environmental surveillance, updating previous reports. In the 19 countries with transmission of PV (WPV and/or circulating vaccine-derived poliovirus [cVDPV]) during 2011-2012, national performance indicator targets were met in 12 (63%) countries in 2011 and 13 (68%) countries in 2012. Seven countries (37%) in 2011 had ≥80% of the population living in areas meeting performance indicators, increasing to nine countries (47%) in 2012. Performance indicators for timely reporting of PV isolation and characterization were met in four of six World Health Organization (WHO) regions in 2011 and five regions in 2012. To achieve global polio eradication, efforts are needed to improve and maintain AFP surveillance and laboratory performance.

  15. Radiation surveillance in Austria in 2000. Dates and evaluation

    International Nuclear Information System (INIS)

    Bobek, E.; Streeruwitz, E.

    2001-11-01

    This report presents results of the radiation surveillance in Austria in 2000, performed by the competent authorities, based on the Austrian Radiation Protection Act. In particular data of large scale monitoring concerning radioactive contamination and of nuclear research reactor emission and immission control are given. In Austria an extensive program is realized for the purpose of large scale surveillance on radioactivity. On the one hand an early radiation warning system with 336 gamma dose rate monitors and several partly nuclide specific air contamination monitors is operated. The data are automatically communicated to various authorities in real-time. On the other hand the radionuclide content of various media such as air, precipitation, surface water, foodstuffs etc is monitored by periodic sampling and subsequent analysis in laboratories. In addition to this routine program special projects are carried out for investigation of specific media and to improve the knowledge of the time dependence respectively of regional aspects of the contamination situation. The inspection of the nuclear installations by the authorities concerning emissions and immissions is set up of two parts: inspection of the quality of the internal control by the operator and independent surveillance by examination of samples taken by the authority. In 2000 the average annual radiation exposure of the Austrian population amounted to about 4.2 mSv effective dose per person. The contributions dominating by far originate from natural and medical sources of radiation. In comparison with these, contributions from all other sources of radiation are extremely small. The average annual effective dose caused by natural radiation amounts to approximately 2.9 mSv per person. The inhalation of the radioactive noble gas radon and its short lived progeny in the mean contributes more than half to this exposure. Mainly because of different radon concentrations considerable variations in natural

  16. Process Evaluation of a Workers' Health Surveillance Program for Meat Processing Workers

    NARCIS (Netherlands)

    van Holland, Berry J; Brouwer, Sandra; de Boer, Michiel R; Reneman, Michiel F; Soer, Remko

    2017-01-01

    Objective To evaluate the implementation process of a workers' health surveillance (WHS) program in a Dutch meat processing company. Methods Workers from five plants were eligible to participate in the WHS program. The program consisted of four evaluative components and an intervention component.

  17. Process Evaluation of a Workers' Health Surveillance Program for Meat Processing Workers

    NARCIS (Netherlands)

    van Holland, Berry; Brouwer, Sandra; de Boer, Michiel R; Reneman, Michiel F; Soer, Remko

    Objective To evaluate the implementation process of a workers' health surveillance (WHS) program in a Dutch meat processing company. Methods Workers from five plants were eligible to participate in the WHS program. The program consisted of four evaluative components and an intervention component.

  18. Evaluation of a Surveillance Review Software based on Automatic Image Summaries

    International Nuclear Information System (INIS)

    Rocchi, S.; Hadfi, G.; John, M.; Moeslinger, M.; Murray, J.; Juengling, K.; Sequeira, V.; Versino, C.; )

    2015-01-01

    Surveillance streams from safeguards instruments contain thousands of images. Inspectors review them in order to find safeguards-relevant events. Statistically a very small fraction of the images is expected to be safeguards-relevant. For this reason inspectors need a tool which helps them to focus their attention directly to the relevant parts of the surveillance stream. The current approach for surveillance review makes use of scene change detection within areas of interest (AOIs). The data reduction provided can be effective for the review of regular processes, and requires specific knowledge of the process/environment under review for the proper setting of the AOIs. The VideoZoom approach, developed by the European Commission Joint Research Centre-Institute for Transuranium Elements (JRC-ITU), detects scene changes on the whole image plane. Changes are then summarized and rendered at different levels of abstraction in four layers of summaries, each one revealing more information about the image changes. By means of a zooming interface, the reviewer is able to navigate the summary layers and decide which are to be examined with full photographic detail or skipped because they are clearly not safeguards-relevant. In this way reviewers can make best use of their time by investigating what really requires their attention. VideoZoom was evaluated by a group of IAEA inspectors on a benchmark of image reviews, with promising results in terms of identification of safeguards-relevant events, efficiency and usability. Following the positive results collected during the preliminary benchmark, the IAEA initiated a task under the European Commission Support Programme (EC SP), aimed at the research, development, and evaluation of surveillance review software based on VideoZoom and compatible with surveillance streams produced by NGSS cameras, the current safeguards surveillance technology deployed by the IAEA. This paper provides a description of the VideoZoom approach to

  19. CCTV Coverage Index Based on Surveillance Resolution and Its Evaluation Using 3D Spatial Analysis

    Directory of Open Access Journals (Sweden)

    Kyoungah Choi

    2015-09-01

    Full Text Available We propose a novel approach to evaluating how effectively a closed circuit television (CCTV system can monitor a targeted area. With 3D models of the target area and the camera parameters of the CCTV system, the approach produces surveillance coverage index, which is newly defined in this study as a quantitative measure for surveillance performance. This index indicates the proportion of the space being monitored with a sufficient resolution to the entire space of the target area. It is determined by computing surveillance resolution at every position and orientation, which indicates how closely a specific object can be monitored with a CCTV system. We present full mathematical derivation for the resolution, which depends on the location and orientation of the object as well as the geometric model of a camera. With the proposed approach, we quantitatively evaluated the surveillance coverage of a CCTV system in an underground parking area. Our evaluation process provided various quantitative-analysis results, compelling us to examine the design of the CCTV system prior to its installation and understand the surveillance capability of an existing CCTV system.

  20. Design, Implementation, and Evaluation of the Adolescents and Surveillance System for the Obesity Prevention Project.

    Science.gov (United States)

    Tabacchi, Garden; Bianco, Antonino; Alessi, Nicola; Filippi, Anna Rita; Napoli, Giuseppe; Jemni, Monèm; Censi, Laura; Breda, João; Schumann, Nathali Lehmann; Firenze, Alberto; Vitale, Francesco; Mammina, Caterina

    2016-03-01

    The Adolescents Surveillance System for Obesity prevention (ASSO) Project aimed at developing standardized and web-based tools for collecting data on adolescents' obesity and its potential determinants. This has been implemented and piloted in the local area of Palermo city, Italy. The aim of the present study is to provide an overview of the Project's design, implementation, and evaluation, highlighting all the aspects for a potential scale-up of the surveillance system on the whole national territory and abroad, as a sustainable and effective source of data.The overall structure and management, the ASSO-toolkit, the ASSO-NutFit software, and all developed and used procedures for recruiting, training, and data collecting/analyzing are addressed. An interim evaluation has been performed through a feasibility study; a final Project evaluation has been performed reporting the Strengths, Weaknesses, Opportunities, and Threats (SWOT) and the attributes that a surveillance system should have.This article provides a detailed overview of the Project and highlights that ASSO can be considered a valid, logical, coherent, efficient, and sustainable surveillance system that is consistent with countries' needs and priorities.The system developed by the ASSO Project provides high-quality data and complies with several characteristics typical of a suitable surveillance system. It has a potential of being adopted within the National Health Service and other countries' Health Services for monitoring adolescents' obesity and its determinants, such as food intakes, behaviors, physical activity, and fitness profiles.

  1. Evaluation of temporal surveillance system sensitivity and freedom from bovine viral diarrhea in Danish dairy herds using scenario tree modelling.

    Science.gov (United States)

    Foddai, Alessandro; Stockmarr, Anders; Boklund, Anette

    2016-06-21

    The temporal sensitivity of the surveillance system (TemSSe) for Bovine Viral Diarrhea (BVD) in Danish dairy herds was evaluated. Currently, the Danish antibody blocking ELISA is used to test quarterly bulk tank milk (BTM). To optimize the surveillance system as an early warning system, we considered the possibility of using the SVANOVIR ELISA, as this test has been shown to detect BVD-positive herds earlier than the blocking ELISA in BTM tests. Information from data (2010) and outputs from two published stochastic models were fed into a stochastic scenario tree to estimate the TemSSe. For that purpose we considered: the risk of BVD introduction into the dairy population, the ELISA used and the high risk period (HRP) from BVD introduction to testing (at 90 or 365 days). The effect of introducing one persistently infected (PI) calf or one transiently infected (TI) milking cow into 1 (or 8) dairy herd(s) was investigated. Additionally we estimated the confidence in low (PLow) herd prevalence (tree methodology, could be applied to optimize early warning surveillance systems of different animal diseases.

  2. Social Influences on Creativity: Evaluation, Coaction, and Surveillance.

    Science.gov (United States)

    Amabile, Teresa M.; And Others

    Two experiments examined the effects of evaluation expectation and the presence of others on creativity in undergraduate students. In both, some Ss expected that their work would be evaluated by experts, while others expected no evaluation. Evaluation expectation was crossed, in each experiment, with the presence of others. In the first…

  3. Specific antigen serologic tests in leprosy: implications for epidemiological surveillance of leprosy cases and household contacts.

    Science.gov (United States)

    Carvalho, Ana Paula Mendes; Coelho, Angélica da Conceição Oliveira; Correa-Oliveira, Rodrigo; Lana, Francisco Carlos Félix

    2017-09-01

    There is a lack of straightforward tests for field application and known biomarkers for predicting leprosy progression in infected individuals. The aim was to analyse the response to infection by Mycobacterium leprae based on the reactivity of specific antigens: natural disaccharide linked to human serum albumin via an octyl (NDOHSA), a semisynthetic phenolic glycolipid-I (PGL-I); Leprosy Infectious Disease Research Institute Diagnostic-1 (LID-1) and natural disaccharide octyl - Leprosy Infectious Disease Research Institute Diagnostic-1 (NDOLID). The study population consisted of 130 leprosy cases diagnosed between 2010 and 2015 and 277 household contacts. An enzyme-linked immunosorbent assay (ELISA) was used to analyse the reactivity of antibodies against NDOHSA, LID-1 and NDOLID. The samples and controls were tested in duplicate, and the antibody titer was expressed as an ELISA index. Data collection was made by home visits with application of questionnaire and dermatological evaluation of all household contacts to identify signs and symptoms of leprosy. Significant differences in the median ELISA results were observed among leprosy cases in treatment, leprosy cases that had completed treatment and household contacts. Higher proportions of seropositivity were observed in leprosy cases in treatment. Seropositivity was also higher in multibacillary in relation to paucibacillary, with the difference reaching statistical significance. Lower titers were observed among cases with a longer treatment time or discharge. For household contacts, the differences according to the clinical characteristics of the leprosy index case were less pronounced than expected. Other factors, such as the endemicity of leprosy, exposure outside the residence and genetic characteristics, appeared to have a greater influence on the seropositivity. Serologic tests could be used as auxiliary tools for determining the operational classification, in addition to identifying infected individuals

  4. Application of advanced irradiation analysis methods to light water reactor pressure vessel test and surveillance programs

    International Nuclear Information System (INIS)

    Odette, R.; Dudey, N.; McElroy, W.; Wullaert, R.; Fabry, A.

    1977-01-01

    Inaccurate characterization and inappropriate application of neutron irradiation exposure variables contribute a substantial amount of uncertainty to embrittlement analysis of light water reactor pressure vessels. Damage analysis involves characterization of the irradiation environment (dosimetry), correlation of test and surveillance metallurgical and dosimetry data, and projection of such data to service conditions. Errors in available test and surveillance dosimetry data are estimated to contribute a factor of approximately 2 to the data scatter. Non-physical (empirical) correlation procedures and the need to extrapolate to the vessel may add further error. Substantial reductions in these uncertainties in future programs can be obtained from a more complete application of available damage analysis tools which have been developed for the fast reactor program. An approach to reducing embrittlement analysis errors is described, and specific examples of potential applications are given. The approach is based on damage analysis techniques validated and calibrated in benchmark environments

  5. Fracture evaluation tests

    International Nuclear Information System (INIS)

    Robinson, G.C.

    1991-01-01

    In this report period, efforts have concentrated on defining the requirements for shallow-flaw beam testing. Analyses have been made to envelope the significant parameters for both deep- and shallow-flaw beams for three-point loading; that is, load to initiation of a frangible flaw, load to plastic collapse, LLD, and CMOD. An assessment was made of facilities capable of performing the tests identified by the parametric analyses discussed above. Two testing machines were identified for performing the scoped test series, the first a 550-kip Instron machine assigned to the Pressure Vessel Technology Section located in Building 9204-1 at the Y-12 Plant and the second a 220-kip MTS machine assigned to a mechanical testing group located at the K-25 Site. An existing bend test fixture previously used in the HSST clad plate test series is being modified for use in testing beams under other sponsorship but will be available for shared usage with the HSST shallow-flaw beam testing activities. To prevent the shared usage from having an adverse impact on the logistics of the HSST Program, the decision was made to procure a bend test fixture tailored specifically to serve the shallow flaw beam test series. A specification was prepared and procurement initiated. A survey is in progress for determining sources and costs of displacement-measuring instrumentation from both foreign and domestic sources. It appears that existing direct current displacement transducers available to the HSST Program may be adequate for the LLD measurements. These devices will be employed in the shakedown tests that are planned. A safety and environmental survey assessment for the beam testing conforming to the revised DOE rules has been prepared and approved

  6. Effects of human errors on the determination of surveillance test interval

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Koo, Bon Hyun

    1990-01-01

    This paper incorporates the effects of human error relevant to the periodic test on the unavailability of the safety system as well as the component unavailability. Two types of possible human error during the test are considered. One is the possibility that a good safety system is inadvertently left in a bad state after the test (Type A human error) and the other is the possibility that bad safety system is undetected upon the test (Type B human error). An event tree model is developed for the steady-state unavailability of safety system to determine the effects of human errors on the component unavailability and the test interval. We perform the reliability analysis of safety injection system (SIS) by applying aforementioned two types of human error to safety injection pumps. Results of various sensitivity analyses show that; 1) the appropriate test interval decreases and steady-state unavailability increases as the probabilities of both types of human errors increase, and they are far more sensitive to Type A human error than Type B and 2) the SIS unavailability increases slightly as the probability of Type B human error increases, and significantly as the probability of Type A human error increases. Therefore, to avoid underestimation, the effects of human error should be incorporated in the system reliability analysis which aims at the relaxations of the surveillance test intervals, and Type A human error has more important effect on the unavailability and surveillance test interval

  7. Evaluation of the surveillance program of Streptococcus agalactiae in Danish dairy herds

    DEFF Research Database (Denmark)

    Andersen, H. J.; Pedersen, L. H.; Aarestrup, Frank Møller

    2003-01-01

    The aim of this study was to evaluate the Danish surveillance program of Streptococcus agalactiae in dairy herds with respect to 1) fluctuation over time of the presence of S. agalactiae in bulk tank milk, 2) sensitivity and specificity of the bacteriological method used, and 3) contamination...... the isolates. Streptococcus agalactiae was found in eight of 96 herds in which S. agalactiae had never previously been found during the surveillance program. Streptococcus agalactiae was not found in all seven sampling rounds in any of the eight herds. Comparing the approved method with supplemental findings...

  8. Integrity assessment of TAPS reactor pressure vessel at extended EOL using surveillance test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah, Priti Kotak

    2008-05-01

    Integrity assessment of pressure vessels of nuclear reactors (RPV) primarily concentrates on the prevention of brittle failure and conditions are defined under which brittle failure can be excluded. Accordingly, two approaches based on Transition Temperature Concept and Fracture Mechanics Concept were adopted using the impact test results of three credible surveillance data sets obtained from the surveillance specimens of Tarapur Atomic Power Station. RT NDT data towards end of life (EOL) were estimated from the impact test results in accordance with the procedures of USNRC Regulatory Guide 1.99, Rev. 2 and were used as primary input for assessment of the vessel integrity. SA302B (nickel modified) steel cladded with stainless steel is used as the pressure vessel material for the two 210 MWe boiling water reactors of the Tarapur Atomic Power Station (TAPS). The reactors were commissioned during the year 1969. The chemical compositions of SA302B (modified) steel used in fabricating the vessel and the specified tensile property and the Charpy impact property requirements of the steel broadly meet ASME specified requirements. Therefore, the pressure temperature limit curves prescribed by General Electric (G.E.) were compared with those as obtained using procedures of ASME Section XII, Appendix G. The tensile and the Charpy impact properties at 60 EFPY of vessel operation as derived from the surveillance specimens even fulfilled the specified requirements for the virgin material of ASME. Integrity assessment carried out using the two approaches indicated the safety of the vessel for continued operation up to 60 EFPY. (author)

  9. Improving allowed outage time and surveillance test interval requirements: a study of their interactions using probabilistic methods

    International Nuclear Information System (INIS)

    Martorell, S.A.; Serradell, V.G.; Samanta, P.K.

    1995-01-01

    Technical Specifications (TS) define the limits and conditions for operating nuclear plants safely. We selected the Limiting Conditions for Operations (LCO) and Surveillance Requirements (SR), both within TS, as the main items to be evaluated using probabilistic methods. In particular, we focused on the Allowed Outage Time (AOT) and Surveillance Test Interval (STI) requirements in LCO and SR, respectively. Already, significant operating and design experience has accumulated revealing several problems which require modifications in some TS rules. Developments in Probabilistic Safety Assessment (PSA) allow the evaluation of effects due to such modifications in AOT and STI from a risk point of view. Thus, some changes have already been adopted in some plants. However, the combined effect of several changes in AOT and STI, i.e. through their interactions, is not addressed. This paper presents a methodology which encompasses, along with the definition of AOT and STI interactions, the quantification of interactions in terms of risk using PSA methods, an approach for evaluating simultaneous AOT and STI modifications, and an assessment of strategies for giving flexibility to plant operation through simultaneous changes on AOT and STI using trade-off-based risk criteria

  10. Post-treatment surveillance testing of patients with colorectal cancer and the association with survival: protocol for a retrospective cohort study of the Surveillance, Epidemiology, and End Results (SEER)-Medicare database.

    Science.gov (United States)

    Hines, Robert B; Jiban, Md Jibanul Haque; Choudhury, Kanak; Loerzel, Victoria; Specogna, Adrian V; Troy, Steven P; Zhang, Shunpu

    2018-04-28

    Although the colorectal cancer (CRC) mortality rate has significantly improved over the past several decades, many patients will have a recurrence following curative treatment. Despite this high risk of recurrence, adherence to CRC surveillance testing guidelines is poor which increases cancer-related morbidity and potentially, mortality. Several randomised controlled trials (RCTs) with varying surveillance strategies have yielded conflicting evidence regarding the survival benefit associated with surveillance testing. However, due to differences in study protocols and limitations of sample size and length of follow-up, the RCT may not be the best study design to evaluate this relationship. An observational comparative effectiveness research study can overcome the sample size/follow-up limitations of RCT designs while assessing real-world variability in receipt of surveillance testing to provide much needed evidence on this important clinical issue. The gap in knowledge that this study will address concerns whether adherence to National Comprehensive Cancer Network CRC surveillance guidelines improves survival. Patients with colon and rectal cancer aged 66-84 years, who have been diagnosed between 2002 and 2008 and have been included in the Surveillance, Epidemiology, and End Results-Medicare database, are eligible for this retrospective cohort study. To minimise bias, patients had to survive at least 12 months following the completion of treatment. Adherence to surveillance testing up to 5 years post-treatment will be assessed in each year of follow-up and overall. Binomial regression will be used to assess the association between patients' characteristics and adherence. Survival analysis will be conducted to assess the association between adherence and 5-year survival. This study was approved by the National Cancer Institute and the Institutional Review Board of the University of Central Florida. The results of this study will be disseminated by publishing in

  11. Evaluating the electronic tuberculosis register surveillance system in Eden District, Western Cape, South Africa, 2015.

    Science.gov (United States)

    Mlotshwa, Mandla; Smit, Sandra; Williams, Seymour; Reddy, Carl; Medina-Marino, Andrew

    2017-01-01

    Tuberculosis (TB) surveillance data are crucial to the effectiveness of National TB Control Programs. In South Africa, few surveillance system evaluations have been undertaken to provide a rigorous assessment of the platform from which the national and district health systems draws data to inform programs and policies. Evaluate the attributes of Eden District's TB surveillance system, Western Cape Province, South Africa. Data quality, sensitivity and positive predictive value were assessed using secondary data from 40,033 TB cases entered in Eden District's ETR.Net from 2007 to 2013, and 79 purposively selected TB Blue Cards (TBCs), a medical patient file and source document for data entered into ETR.Net. Simplicity, flexibility, acceptability, stability and usefulness of the ETR.Net were assessed qualitatively through interviews with TB nurses, information health officers, sub-district and district coordinators involved in the TB surveillance. TB surveillance system stakeholders report that Eden District's ETR.Net system was simple, acceptable, flexible and stable, and achieves its objective of informing TB control program, policies and activities. Data were less complete in the ETR.Net (66-100%) than in the TBCs (76-100%), and concordant for most variables except pre-treatment smear results, antiretroviral therapy (ART) and treatment outcome. The sensitivity of recorded variables in ETR.Net was 98% for gender, 97% for patient category, 93% for ART, 92% for treatment outcome and 90% for pre-treatment smear grading. Our results reveal that the system provides useful information to guide TB control program activities in Eden District. However, urgent attention is needed to address gaps in clinical recording on the TBC and data capturing into the ETR.Net system. We recommend continuous training and support of TB personnel involved with TB care, management and surveillance on TB data recording into the TBCs and ETR.Net as well as the implementation of a well

  12. Uptake of genetic testing and long-term tumor surveillance in von Hippel-Lindau disease

    Directory of Open Access Journals (Sweden)

    Chávez Mireya

    2010-01-01

    Full Text Available Abstract Background von Hippel-Lindau (VHL disease is a hereditary cancer syndrome caused by germline mutations in the VHL gene. Patients have significant morbidity and mortality secondary to vascular tumors. Disease management is centered on tumor surveillance that allows early detection and treatment. Presymptomatic genetic testing is therefore recommended, including in at-risk children. Methods We tested 17 families (n = 109 individuals for VHL mutations including 43 children under the age of 18. Personalized genetic counseling was provided pre and post-test and the individuals undergoing presymptomatic testing filled out questionnaires gathering socio-demographic, psychological and psychiatric data. Mutation analysis was performed by direct sequencing of the VHL gene. Mutation-carriers were screened for VHL disease-related tumors and were offered follow-up annual examinations. Results Mutations were identified in 36 patients, 17 of whom were asymptomatic. In the initial screening, we identified at least one tumor in five of 17 previously asymptomatic individuals. At the end of five years, only 38.9% of the mutation-carriers continued participating in our tumor surveillance program. During this time, 14 mutation carriers developed a total of 32 new tumors, three of whom died of complications. Gender, education, income, marital status and religiosity were not found to be associated with adherence to the surveillance protocol. Follow-up adherence was also independent of pre-test depression, severity of disease, or number of affected family members. The only statistically significant predictor of adherence was being symptomatic at the time of testing (OR = 5; 95% CI 1.2 - 20.3; p = 0.02. Pre-test anxiety was more commonly observed in patients that discontinued follow-up (64.7% vs. 35.3%; p = 0.01. Conclusions The high initial uptake rate of genetic testing for VHL disease, including in minors, allowed the discontinuation of unnecessary screening

  13. Large-scale machine learning and evaluation platform for real-time traffic surveillance

    Science.gov (United States)

    Eichel, Justin A.; Mishra, Akshaya; Miller, Nicholas; Jankovic, Nicholas; Thomas, Mohan A.; Abbott, Tyler; Swanson, Douglas; Keller, Joel

    2016-09-01

    In traffic engineering, vehicle detectors are trained on limited datasets, resulting in poor accuracy when deployed in real-world surveillance applications. Annotating large-scale high-quality datasets is challenging. Typically, these datasets have limited diversity; they do not reflect the real-world operating environment. There is a need for a large-scale, cloud-based positive and negative mining process and a large-scale learning and evaluation system for the application of automatic traffic measurements and classification. The proposed positive and negative mining process addresses the quality of crowd sourced ground truth data through machine learning review and human feedback mechanisms. The proposed learning and evaluation system uses a distributed cloud computing framework to handle data-scaling issues associated with large numbers of samples and a high-dimensional feature space. The system is trained using AdaBoost on 1,000,000 Haar-like features extracted from 70,000 annotated video frames. The trained real-time vehicle detector achieves an accuracy of at least 95% for 1/2 and about 78% for 19/20 of the time when tested on ˜7,500,000 video frames. At the end of 2016, the dataset is expected to have over 1 billion annotated video frames.

  14. Material control test and evaluation system at the ICPP

    International Nuclear Information System (INIS)

    Johnson, C.E.

    1979-01-01

    The US DOE is evaluating process monitoring as part of a total nuclear material safeguards system. A monitoring system is being installed at the Idaho Chemical Processing Plant to test and evaluate material control and surveillance concepts in an operating nuclear fuel reprocessing plant. Process monitoring for nuclear material control complements conventional safeguards accountability and physical protection to assure adherence to approved safeguards procedures and verify containment of nuclear materials within the processing plant

  15. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christie, B.

    1996-12-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. {open_quotes}Conditional Probabilities{close_quotes} of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps.

  16. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    International Nuclear Information System (INIS)

    Christie, B.

    1996-01-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. open-quotes Conditional Probabilitiesclose quotes of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps

  17. Framework for evaluating public health surveillance systems for early detection of outbreaks: recommendations from the CDC Working Group.

    Science.gov (United States)

    Buehler, James W; Hopkins, Richard S; Overhage, J Marc; Sosin, Daniel M; Tong, Van

    2004-05-07

    The threat of terrorism and high-profile disease outbreaks has drawn attention to public health surveillance systems for early detection of outbreaks. State and local health departments are enhancing existing surveillance systems and developing new systems to better detect outbreaks through public health surveillance. However, information is limited about the usefulness of surveillance systems for outbreak detection or the best ways to support this function. This report supplements previous guidelines for evaluating public health surveillance systems. Use of this framework is intended to improve decision-making regarding the implementation of surveillance for outbreak detection. Use of a standardized evaluation methodology, including description of system design and operation, also will enhance the exchange of information regarding methods to improve early detection of outbreaks. The framework directs particular attention to the measurement of timeliness and validity for outbreak detection. The evaluation framework is designed to support assessment and description of all surveillance approaches to early detection, whether through traditional disease reporting, specialized analytic routines for aberration detection, or surveillance using early indicators of disease outbreaks, such as syndromic surveillance.

  18. Transitioning from antenatal surveillance surveys to routine HIV testing: a turning point in the mother-to-child transmission prevention programme for HIV surveillance in Brazil.

    Science.gov (United States)

    Pereira, Gerson Fernando Mendes; Sabidó, Meritxell; Caruso, Alessandro; Benzaken, Adele Schwartz

    2017-07-05

    In Brazil, due to the rapid increase in programmes for the prevention of mother-to-child transmission (PMTCT), routine programme data are widely available. The objective of this study was to assess the utility of programmatic data to replace HIV surveillance based on the antenatal care (ANC) surveillance survey (SS). We analysed ANC SS data from 219 maternity service clinics. PMTCT variables were extracted from the ANC SS data collection form, which allowed us to capture and compare the ANC SS data and PMTCT HIV test results for each pregnant woman who completed the ANC SS. Both the PMTCT programme and the ANC SS tested for HIV using sequential ELISA and western blot for confirmation. We assessed the completeness (% missing) of the PMTC data included in the ANC SS. Of the 36,713 pregnant women who had ANC SS HIV tests performed, 30,588 also underwent PMTCT HIV testing. The HIV prevalence rate from routine PMTCT testing was 0.36%, compared to 0.38% from the ANC SS testing (relative difference -0.05%; absolute difference -0.02%). The relative difference in prevalence rates between pregnant women in northern Brazil and pregnant women central-west Brazil was -0.98 and 0.66, respectively. Of the 29,856 women who had HIV test results from both the PMTCT and ANC SS, the positive percent agreement of the PMTCT versus the surveillance test was 84.1% (95% confidence interval [CI]: 74.8-91.0), and the negative percent agreement was 99.9% (95% CI: 99.9-100.0). The PMTCT HIV testing uptake was 86.4%. The ANC SS HIV prevalence was 0.33% among PMTCT non-refusers and 0.59% among refusers, with a percent bias of -10.80% and a differential prevalence ratio of 0.56. Syphilis and HIV testing results were complete in 98% and 97.6% of PMTCT reports, respectively. The reported HIV status for the women at clinic entry was missing. Although there were consistent HIV prevalence estimates from the PMTCT data and the ANC SS, the overall positive percent agreement of 84.1% falls below the

  19. PET-CT in Staging, Response Evaluation, and Surveillance of Lymphoma.

    Science.gov (United States)

    Thanarajasingam, Gita; Bennani-Baiti, Nabila; Thompson, Carrie A

    2016-05-01

    Lymphoma represents a broad spectrum of diseases with diverse biology, clinical behavior, and imaging features. Functional imaging with 18-F-fluorodeoxyglucose (FDG)-positron emission tomography combined with computed tomography (PET-CT) is widely recognized as the most sensitive and specific imaging modality for patients with lymphoma and is used as part of staging, response evaluation, and surveillance in patients with Hodgkin (HL) and non-Hodgkin lymphoma (NHL). Recent efforts at standardizing the conduct and consensus interpretation of PET-CT have facilitated its use in patients on clinical studies and beyond. The role of PET-CT has been affirmed in some clinical situations, such as staging and end-of-treatment evaluation in Hodgkin lymphoma and diffuse large B cell lymphoma (DLBCL), and in the evaluation of aggressive transformation of an indolent lymphoma. However, the role of functional imaging in other histologies and clinical settings is not as clear given the higher rate of false positive results and the costs inherent to PET-CT. There is little evidence to suggest its utility or impact on outcome in most indolent lymphomas, or in the setting of post-treatment surveillance. In addition, there remains controversy about the value of PET-CT in early response assessment during active therapy, particularly in DLBCL. This review will evaluate the evidence surrounding the role of PET-CT in staging, response evaluation and surveillance of Hodgkin and non-Hodgkin lymphoma.

  20. A study on assessment methodology of surveillance test interval and allowed outage time

    International Nuclear Information System (INIS)

    Che, Moo Seong; Cheong, Chang Hyeon; Lee, Byeong Cheol

    1996-07-01

    The objectives of this study is the development of methodology by which assessing the optimizes Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korea nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches is performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method

  1. A study on assessment methodology of surveillance test interval and allowed outage time

    Energy Technology Data Exchange (ETDEWEB)

    Che, Moo Seong; Cheong, Chang Hyeon; Lee, Byeong Cheol [Seoul Nationl Univ., Seoul (Korea, Republic of)] (and others)

    1996-07-15

    The objectives of this study is the development of methodology by which assessing the optimizes Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korea nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches is performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method.

  2. Evaluation of PM-10 commercial inlets for new surveillance air sampler

    International Nuclear Information System (INIS)

    Langer, G.

    1986-01-01

    The inlet for the present Rock Flats Plant surveillance sampler does not meet the new but still tentative PM-10 (<10-μm particle mass) criterion for sampling the hazardous fraction of airborne dust. Since this criterion relates mainly to non-radioactive emissions, DOE and EPA are presently in the process of promulgating emission guidelines specifically for non-reactor DOE nuclear facilities. The authors present approach is to select a commercial inlet and modify its, if necessary, to meet the PM-10 criterion, keeping in mind that they may have to recover the dust collected in the inlet. There is no EPA-approved PM-10 inlet design; instead, EPA issued a performance specification. As a nuclear operation, Rocky Flats has to sample continuously to ensure no period remains unmonitored, instead of every sixth day, as set forth by EPA for non-nuclear installations. During this study period, the authors developed an inlet evaluation methodology to meet the above, anticipated EPA requirements. Also, they started testing two potential inlets. 6 references, 2 figures, 1 table

  3. Clinimetric quality of the fire fighting simulation test as part of the Dutch fire fighters Workers' Health Surveillance

    Directory of Open Access Journals (Sweden)

    Sluiter Judith K

    2010-02-01

    Full Text Available Abstract Background Clinimetric data for the fire fighting simulation test (FFST, a new test proposed for the Workers' Health Surveillance (WHS of Dutch fire fighters, were evaluated. Methods Twenty-one fire fighters took the FFST three times with one and three weeks between testing. Clinimetric quality was determined by means of reliability, agreement and validity. For reliability and agreement, the intraclass correlation coefficient (ICC, and standard error of measurement (SEM, were analysed. For construct validity, the tests from 45 fire fighters were correlated with their own and their supervisors' rated work ability. Results The ICCs were 0.56 and 0.79 at the one-week and three-week test-retest periods, respectively. Testing times ranged from 9 to 17 minutes; the SEMs were 70 s at the one-week and 40 s at the three-week test-retest periods. The construct validity was moderate (-0.47 ≤ r ≤ -0.33; p Conclusions The FFST was reliable with acceptable agreement after three weeks. Construct validity was moderate. We recommend using FFST as a part of the WHS for Dutch fire fighters. It is advised that fire fighters should perform the FFST once as a trial before judging their performance in testing time during the second performance.

  4. Development of a test of suprathreshold acuity in noise in Brazilian Portuguese: a new method for hearing screening and surveillance.

    Science.gov (United States)

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: "a hearing check is recommended" (red light), "a hearing check would be advisable" (yellow light), and "no hearing difficulties" (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.

  5. Development of a Test of Suprathreshold Acuity in Noise in Brazilian Portuguese: A New Method for Hearing Screening and Surveillance

    Directory of Open Access Journals (Sweden)

    Nara Vaez

    2014-01-01

    Full Text Available This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: “a hearing check is recommended” (red light, “a hearing check would be advisable” (yellow light, and “no hearing difficulties” (green light (Paglialonga et al., Comput. Biol. Med. 2014. This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.

  6. Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.

    Directory of Open Access Journals (Sweden)

    Joseph R Egger

    Full Text Available BACKGROUND: Postmarketing surveillance is routinely conducted to monitor performance of pharmaceuticals and testing devices in the marketplace. However, these surveillance methods are often done retrospectively and, as a result, are not designed to detect issues with performance in real-time. METHODS AND FINDINGS: Using HIV antibody screening test data from New York City STD clinics, we developed a formal, statistical method of prospectively detecting temporal clusters of poor performance of a screening test. From 2005 to 2008, New York City, as well as other states, observed unexpectedly high false-positive (FP rates in an oral fluid-based rapid test used for screening HIV. We attempted to formally assess whether the performance of this HIV screening test statistically deviated from both local expectation and the manufacturer's claim for the test. Results indicate that there were two significant temporal clusters in the FP rate of the oral HIV test, both of which exceeded the manufacturer's upper limit of the 95% CI for the product. Furthermore, the FP rate of the test varied significantly by both STD clinic and test lot, though not by test operator. CONCLUSIONS: Continuous monitoring of surveillance data has the benefit of providing information regarding test performance, and if conducted in real-time, it can enable programs to examine reasons for poor test performance in close proximity to the occurrence. Techniques used in this study could be a valuable addition for postmarketing surveillance of test performance and may become particularly important with the increase in rapid testing methods.

  7. Cost-effectiveness of lobectomy versus genetic testing (Afirma®) for indeterminate thyroid nodules: Considering the costs of surveillance.

    Science.gov (United States)

    Balentine, Courtney J; Vanness, David J; Schneider, David F

    2018-01-01

    We evaluated whether diagnostic thyroidectomy for indeterminate thyroid nodules would be more cost-effective than genetic testing after including the costs of long-term surveillance. We used a Markov decision model to estimate the cost-effectiveness of thyroid lobectomy versus genetic testing (Afirma®) for evaluation of indeterminate (Bethesda 3-4) thyroid nodules. The base case was a 40-year-old woman with a 1-cm indeterminate nodule. Probabilities and estimates of utilities were obtained from the literature. Cost estimates were based on Medicare reimbursements with a 3% discount rate for costs and quality-adjusted life-years. During a 5-year period after the diagnosis of indeterminate thyroid nodules, lobectomy was less costly and more effective than Afirma® (lobectomy: $6,100; 4.50 quality-adjusted life- years vs Afirma®: $9,400; 4.47 quality-adjusted life-years). Only in 253 of 10,000 simulations (2.5%) did Afirma® show a net benefit at a cost-effectiveness threshold of $100,000 per quality- adjusted life-years. There was only a 0.3% probability of Afirma® being cost saving and a 14.9% probability of improving quality-adjusted life-years. Our base case estimate suggests that diagnostic lobectomy dominates genetic testing as a strategy for ruling out malignancy of indeterminate thyroid nodules. These results, however, were highly sensitive to estimates of utilities after lobectomy and living under surveillance after Afirma®. Published by Elsevier Inc.

  8. Evaluation 2000 and regulation and method. Release monitoring and environmental surveillance around Cea centers

    International Nuclear Information System (INIS)

    2001-06-01

    This publication counts for the year 2000 for the evaluation of liquid and gaseous radioactive effluents releases and the radioactivity levels measured in the vicinity of Cea centers, through the air, water, vegetation and milk surveillance. An analysis of the results from 1996 to 2000 allows to follow their evolution. A second booklet develops the sampling and measurement methods made on effluents in environment. It present besides the regulation applied to effluents monitoring. (N.C.)

  9. Advanced Vehicle Testing and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Garetson, Thomas [The Clarity Group, Incorporated, Chicago, IL (United States)

    2013-03-31

    The objective of the United States (U.S.) Department of Energy's (DOEs) Advanced Vehicle Testing and Evaluation (AVTE) project was to provide test and evaluation services for advanced technology vehicles, to establish a performance baseline, to determine vehicle reliability, and to evaluate vehicle operating costs in fleet operations.Vehicles tested include light and medium-duty vehicles in conventional, hybrid, and all-electric configurations using conventional and alternative fuels, including hydrogen in internal combustion engines. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing.

  10. Final report : mobile surveillance and wireless communication systems field operational test. Volume 1, Executive summary

    Science.gov (United States)

    1999-03-01

    This study focused on assessing the application of traffic monitoring and management systems which use transportable surveillance and ramp meter trailers, video image processors, and wireless communications. The mobile surveillance and wireless commu...

  11. A retrospective study of owner-requested testing as surveillance for equine infectious anemia in Canada (2009-2012).

    Science.gov (United States)

    Higgins, Sara N; Howden, Krista J; James, Carolyn R; Epp, Tasha; Lohmann, Katharina L

    2017-12-01

    This retrospective study was undertaken to estimate i) the surveillance coverage for equine infectious anemia (EIA) based on owner-requested testing, and ii) the incidence of case detection from this surveillance activity to inform a review of Canada's national disease control strategy. Based on sample submissions by accredited veterinarians to laboratories CFIA-approved for EIA testing between 2009 and 2012, the estimated national surveillance coverage was 14% for all years, and 72 cases of EIA were detected. The annual national incidence of EIA detection ranged from 0.03 to 0.08 cases/1000 horses. On average, a greater proportion of the horse population was tested in eastern Canada (32%) than in western Canada (6%, P Canada (0.25 cases/1000 horses) than in eastern Canada (0.02 cases/1000 horses, P < 0.0001). This study identified regional differences in owner-requested EIA testing and case detection resulting from this testing activity.

  12. HIV test offers and acceptance: New York State findings from the behavioral risk factor surveillance system and the National HIV behavioral surveillance, 2011-2012.

    Science.gov (United States)

    John Leung, Shu-Yin; Sinclair, Amber H; Battles, Haven B; Swain, Carol-Ann E; French, Patrick Tyler; Anderson, Bridget J; Sowizral, Mycroft J; Ruberto, Rachael; Brissette, Ian; Lillquist, Patricia; Smith, Lou C

    2015-01-01

    The New York State HIV testing law requires that patients aged 13-64 years be offered HIV testing in health care settings. We investigated the extent to which HIV testing was offered and accepted during the 24 months after law enactment. We added local questions to the Behavioral Risk Factor Surveillance System (BRFSS) and the National HIV Behavioral Surveillance (NHBS) surveys asking respondents aged 18-64 years whether they were offered an HIV test in health care settings, and whether they had accepted testing. Statewide prevalence estimates of test offers and acceptance were obtained from a combined 2011-2012 BRFSS sample (N = 6,223). Local estimates for 2 high-risk populations were obtained from NHBS 2011 men who have sex with men (N = 329) and 2012 injection drug users (N = 188) samples. BRFSS data showed that 73% of New Yorkers received care in any health care setting in the past 12 months, of whom 25% were offered an HIV test. Sixty percent accepted the test when offered. The levels of test offer increased from 20% to 29% over time, whereas acceptance levels decreased from 68% to 53%. NHBS data showed that 81% of men who have sex with men received care, of whom 43% were offered an HIV test. Eighty-eight percent accepted the test when offered. Eighty-five percent of injection drug users received care, of whom 63% were offered an HIV test, and 63% accepted the test when offered. We found evidence of partial and increasing implementation of the HIV testing law. Importantly, these studies demonstrated New Yorkers' willingness to accept an offered HIV test as part of routine care in health care settings.

  13. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  14. Testing of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Bobbe, J.G.

    1995-01-01

    In the evaluation of the safety of radioactive material transportation it is important to consider the response of Type B packages to environments more severe than that prescribed by the hypothetical accident sequence in Title 10 Part 71 of the Code of Federal Regulations (NRC 1995). The impact event in this sequence is a 9-meter drop onto an essentially unyielding target, resulting in an impact velocity of 13.4 m/s. The behavior of 9 packages when subjected to impacts more severe than this is not well known. It is the purpose of this program to evaluate the structural response of a test package to these environments. Several types of structural response are considered. Of primary importance is the behavior of the package containment boundary, including the bolted closure and 0-rings. Other areas of concern are loss of shielding capability due to lead slump and the deceleration loading of package contents, that may cause damage to them. This type of information is essential for conducting accurate risk assessments on the transportation of radioactive materials. Currently very conservative estimates of the loss of package protection are used in these assessments. This paper will summarize the results of a regulatory impact test and three extra-regulatory impact tests on a sample package

  15. Environmental surveillance and research at the Nevada Test Site: The beginning and the rationale

    International Nuclear Information System (INIS)

    Elle, D.R.; Church, B.W.; Bingham, F.E.

    1990-01-01

    Concurrently with the first nuclear-weapons tests at the Nevada Test Site (NTS) in 1951, an environmental surveillance and monitoring program was established offsite. Initial emphasis was on tracking fallout clouds and measuring external radiation exposure rates. An environmental research program was also initiated. Establishment of comprehensive programs has facilitated the ability to address issues such as the inventory and distribution of radionuclides in surface soils, reconstruction of offsite population doses, and recognition of areas requiring additional information. We have learned that a successful environmental monitoring program must be flexible and responsive to change; must address public as well as technical and regulatory concerns; and results must be continuously interpreted to ensure that all pathways are considered and the programs are proactive in their approach

  16. A labelled discrete choice experiment adds realism to the choices presented: preferences for surveillance tests for Barrett esophagus

    Directory of Open Access Journals (Sweden)

    Donkers Bas

    2009-05-01

    Full Text Available Abstract Background Discrete choice experiments (DCEs allow systematic assessment of preferences by asking respondents to choose between scenarios. We conducted a labelled discrete choice experiment with realistic choices to investigate patients' trade-offs between the expected health gains and the burden of testing in surveillance of Barrett esophagus (BE. Methods Fifteen choice scenarios were selected based on 2 attributes: 1 type of test (endoscopy and two less burdensome fictitious tests, 2 frequency of surveillance. Each test-frequency combination was associated with its own realistic decrease in risk of dying from esophageal adenocarcinoma. A conditional logit model was fitted. Results Of 297 eligible patients (155 BE and 142 with non-specific upper GI symptoms, 247 completed the questionnaire (84%. Patients preferred surveillance to no surveillance. Current surveillance schemes of once every 1–2 years were amongst the most preferred alternatives. Higher health gains were preferred over those with lower health gains, except when test frequencies exceeded once a year. For similar health gains, patients preferred video-capsule over saliva swab and least preferred endoscopy. Conclusion This first example of a labelled DCE using realistic scenarios in a healthcare context shows that such experiments are feasible. A comparison of labelled and unlabelled designs taking into account setting and research question is recommended.

  17. Standard Test Method for Application and Analysis of Helium Accumulation Fluence Monitors for Reactor Vessel Surveillance, E706 (IIIC)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes the concept and use of helium accumulation for neutron fluence dosimetry for reactor vessel surveillance. Although this test method is directed toward applications in vessel surveillance, the concepts and techniques are equally applicable to the general field of neutron dosimetry. The various applications of this test method for reactor vessel surveillance are as follows: 1.1.1 Helium accumulation fluence monitor (HAFM) capsules, 1.1.2 Unencapsulated, or cadmium or gadolinium covered, radiometric monitors (RM) and HAFM wires for helium analysis, 1.1.3 Charpy test block samples for helium accumulation, and 1.1.4 Reactor vessel (RV) wall samples for helium accumulation. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Statistical analysis on the fluence factor of surveillance test data of Korean nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyeong Geun; Kim, Min Chul; Yoon, Ji Hyun; Lee, Bong Sang; Lim, Sang Yeob; Kwon, Jun Hyun [Nuclear Materials Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    The transition temperature shift (TTS) of the reactor pressure vessel materials is an important factor that determines the lifetime of a nuclear power plant. The prediction of the TTS at the end of a plant’s lifespan is calculated based on the equation of Regulatory Guide 1.99 revision 2 (RG1.99/2) from the US. The fluence factor in the equation was expressed as a power function, and the exponent value was determined by the early surveillance data in the US. Recently, an advanced approach to estimate the TTS was proposed in various countries for nuclear power plants, and Korea is considering the development of a new TTS model. In this study, the TTS trend of the Korean surveillance test results was analyzed using a nonlinear regression model and a mixed-effect model based on the power function. The nonlinear regression model yielded a similar exponent as the power function in the fluence compared with RG1.99/2. The mixed-effect model had a higher value of the exponent and showed superior goodness of fit compared with the nonlinear regression model. Compared with RG1.99/2 and RG1.99/3, the mixed-effect model provided a more accurate prediction of the TTS.

  19. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013

    DEFF Research Database (Denmark)

    Condell, Orla; Midgley, Sofie E; Christiansen, Claus Bohn

    2016-01-01

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission......The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus......-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical...... information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory...

  20. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance.

    Science.gov (United States)

    Murphy, Sean C; Hermsen, Cornelus C; Douglas, Alexander D; Edwards, Nick J; Petersen, Ines; Fahle, Gary A; Adams, Matthew; Berry, Andrea A; Billman, Zachary P; Gilbert, Sarah C; Laurens, Matthew B; Leroy, Odile; Lyke, Kristen E; Plowe, Christopher V; Seilie, Annette M; Strauss, Kathleen A; Teelen, Karina; Hill, Adrian V S; Sauerwein, Robert W

    2014-01-01

    Nucleic acid testing (NAT) for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal external quality assurance (EQA) program provides validation for the assays in use. Here, we report results of an EQA exercise for malaria NAT assays. Among five centers conducting controlled human malaria infection trials, all centers achieved 100% specificity and demonstrated limits of detection consistent with each laboratory's pre-stated expectations. Quantitative bias of reported results compared to expected results was generally Quality Assessment program that fulfills the need for EQA of malaria NAT assays worldwide.

  1. Hospitalization records as a tool for evaluating performance of food- and water-borne disease surveillance systems: a Massachusetts case study.

    Science.gov (United States)

    Mor, Siobhan M; DeMaria, Alfred; Naumova, Elena N

    2014-01-01

    We outline a framework for evaluating food- and water-borne surveillance systems using hospitalization records, and demonstrate the approach using data on salmonellosis, campylobacteriosis and giardiasis in persons aged ≥65 years in Massachusetts. For each infection, and for each reporting jurisdiction, we generated smoothed standardized morbidity ratios (SMR) and surveillance to hospitalization ratios (SHR) by comparing observed surveillance counts with expected values or the number of hospitalized cases, respectively. We examined the spatial distribution of SHR and related this to the mean for the entire state. Through this approach municipalities that deviated from the typical experience were identified and suspected of under-reporting. Regression analysis revealed that SHR was a significant predictor of SMR, after adjusting for population age-structure. This confirms that the spatial "signal" depicted by surveillance is in part influenced by inconsistent testing and reporting practices since municipalities that reported fewer cases relative to the number of hospitalizations had a lower relative risk (as estimated by SMR). Periodic assessment of SHR has potential in assessing the performance of surveillance systems.

  2. Hospitalization records as a tool for evaluating performance of food- and water-borne disease surveillance systems: a Massachusetts case study.

    Directory of Open Access Journals (Sweden)

    Siobhan M Mor

    Full Text Available We outline a framework for evaluating food- and water-borne surveillance systems using hospitalization records, and demonstrate the approach using data on salmonellosis, campylobacteriosis and giardiasis in persons aged ≥65 years in Massachusetts. For each infection, and for each reporting jurisdiction, we generated smoothed standardized morbidity ratios (SMR and surveillance to hospitalization ratios (SHR by comparing observed surveillance counts with expected values or the number of hospitalized cases, respectively. We examined the spatial distribution of SHR and related this to the mean for the entire state. Through this approach municipalities that deviated from the typical experience were identified and suspected of under-reporting. Regression analysis revealed that SHR was a significant predictor of SMR, after adjusting for population age-structure. This confirms that the spatial "signal" depicted by surveillance is in part influenced by inconsistent testing and reporting practices since municipalities that reported fewer cases relative to the number of hospitalizations had a lower relative risk (as estimated by SMR. Periodic assessment of SHR has potential in assessing the performance of surveillance systems.

  3. Evaluation of cholera surveillance system in Osu Klottey District, Accra, Ghana (2011-2013).

    Science.gov (United States)

    Adjei, Eric Yirenkyi; Malm, Keziah Laurencia; Mensah, Kofi Nyarko; Sackey, Samuel Oko; Ameme, Donne; Kenu, Ernest; Abdulai, Marijanatu; Mills, Richael; Afari, Edwin

    2017-01-01

    Cholera is an acute illness characterized by profuse watery diarrhea. It is caused by vibrio cholera subgroup 01 and 0139. Rapid administration of fluid replacement therapy and supportive treatment can reduce mortality to around 1%. By the close of 2011, 10,628 cases and 100 deaths were reported in Ghana with a case fatality rate of 0.99. It is important to evaluate the cholera surveillance system in Ghana to determine if it is meeting its objective. The study was conducted in Osu Klottey district in the Accra Metropolitan area in January 2014. We assessed the operations (attributes and performance) of the surveillance system for cholera using CDC guidelines (2001). Surveillance data records at the district level from 2011-2013 were extracted and analyzed for frequency using Microsoft excel. Stakeholders and key informants were interviewed using structured questionnaire. Records were also reviewed at some health facilities and at district levels. In 2011 and 2012, case fatality rates (1.3% and 0.65%) respectively. Males were mostly affected. The most affected age group was 20-29. In 2011, Predictive value positive was 69.2% and 50% in 2012.Cholera peaked in March 2011 and April 2012. The Government of Ghana funded the system. The system is sensitive, simple, stable, flexible, acceptable and representative. It was also useful and data quality was relatively good. Predictive Value Positive was also good. The surveillance system is achieving its set out objectives. The system is sensitive, simple, stable, flexible, and acceptable. Predictive value positive was good.

  4. Evaluation of the national Notifiable Diseases Surveillance System for dengue fever in Taiwan, 2010-2012.

    Directory of Open Access Journals (Sweden)

    Caoimhe McKerr

    2015-03-01

    Full Text Available In Taiwan, around 1,500 cases of dengue fever are reported annually and incidence has been increasing over time. A national web-based Notifiable Diseases Surveillance System (NDSS has been in operation since 1997 to monitor incidence and trends and support case and outbreak management. We present the findings of an evaluation of the NDSS to ascertain the extent to which dengue fever surveillance objectives are being achieved.We extracted the NDSS data on all laboratory-confirmed dengue fever cases reported during 1 January 2010 to 31 December 2012 to assess and describe key system attributes based on the Centers for Disease Control and Prevention surveillance evaluation guidelines. The system's structure and processes were delineated and operational staff interviewed using a semi-structured questionnaire. Crude and age-adjusted incidence rates were calculated and key demographic variables were summarised to describe reporting activity. Data completeness and validity were described across several variables.Of 5,072 laboratory-confirmed dengue fever cases reported during 2010-2012, 4,740 (93% were reported during July to December. The system was judged to be simple due to its minimal reporting steps. Data collected on key variables were correctly formatted and usable in > 90% of cases, demonstrating good data completeness and validity. The information collected was considered relevant by users with high acceptability. Adherence to guidelines for 24-hour reporting was 99%. Of 720 cases (14% recorded as travel-related, 111 (15% had an onset >14 days after return, highlighting the potential for misclassification. Information on hospitalization was missing for 22% of cases. The calculated PVP was 43%.The NDSS for dengue fever surveillance is a robust, well maintained and acceptable system that supports the collection of complete and valid data needed to achieve the surveillance objectives. The simplicity of the system engenders compliance leading to

  5. Multicenter Evaluation of a Novel Surveillance Paradigm for Complications of Mechanical Ventilation

    Science.gov (United States)

    Klompas, Michael; Khan, Yosef; Kleinman, Kenneth; Evans, R. Scott; Lloyd, James F.; Stevenson, Kurt; Samore, Matthew; Platt, Richard

    2011-01-01

    Background Ventilator-associated pneumonia (VAP) surveillance is time consuming, subjective, inaccurate, and inconsistently predicts outcomes. Shifting surveillance from pneumonia in particular to complications in general might circumvent the VAP definition's subjectivity and inaccuracy, facilitate electronic assessment, make interfacility comparisons more meaningful, and encourage broader prevention strategies. We therefore evaluated a novel surveillance paradigm for ventilator-associated complications (VAC) defined by sustained increases in patients' ventilator settings after a period of stable or decreasing support. Methods We assessed 600 mechanically ventilated medical and surgical patients from three hospitals. Each hospital contributed 100 randomly selected patients ventilated 2–7 days and 100 patients ventilated >7 days. All patients were independently assessed for VAP and for VAC. We compared incidence-density, duration of mechanical ventilation, intensive care and hospital lengths of stay, hospital mortality, and time required for surveillance for VAP and for VAC. A subset of patients with VAP and VAC were independently reviewed by a physician to determine possible etiology. Results Of 597 evaluable patients, 9.3% had VAP (8.8 per 1,000 ventilator days) and 23% had VAC (21.2 per 1,000 ventilator days). Compared to matched controls, both VAP and VAC prolonged days to extubation (5.8, 95% CI 4.2–8.0 and 6.0, 95% CI 5.1–7.1 respectively), days to intensive care discharge (5.7, 95% CI 4.2–7.7 and 5.0, 95% CI 4.1–5.9), and days to hospital discharge (4.7, 95% CI 2.6–7.5 and 3.0, 95% CI 2.1–4.0). VAC was associated with increased mortality (OR 2.0, 95% CI 1.3–3.2) but VAP was not (OR 1.1, 95% CI 0.5–2.4). VAC assessment was faster (mean 1.8 versus 39 minutes per patient). Both VAP and VAC events were predominantly attributable to pneumonia, pulmonary edema, ARDS, and atelectasis. Conclusions Screening ventilator settings for VAC captures a

  6. Schistosomiasis in Scottish travellers: public health importance of laboratory testing and the need for enhanced surveillance.

    Science.gov (United States)

    Alexander, Claire L; Cottom, Laura; Smith, Kitty; Perrow, Kali; Coyne, Michael; Jones, Brian L

    2018-03-01

    Imported schistosomiasis is of significant public health importance and is likely to be underestimated since infection is often asymptomatic. We describe data from travellers residing in Scotland which includes a subset of group travellers from one of the largest Health Boards in Scotland. Clotted bloods were obtained during the period 2001-15 from a total of 8163 Scottish travellers. This included seven groups comprising of 182 travellers. Sera were examined for the presence of Schistosome species antibody at the Scottish Parasite Diagnostic and Reference Laboratory (SPDRL). Of all, 25% (n = 1623) tested positive with 40% (n = 651) of those patients aged between 20 and 24 years. Although 62% (n = 1006) of those who tested positive reported travel to Africa, important information on the specific region visited was lacking in almost one-third of samples received. Overall, 62 (34%) of group travellers tested positive and 95% (n = 59) reporting travel to Africa. Globalization, affordable air travel and improved awareness, are likely to contribute towards the increasing number of imported schistosomiasis cases. Therefore, enhanced surveillance capturing detailed travel history and fresh water exposures will improve risk stratification, pre-travel advice and optimize testing and treatment regimes for this increasingly important parasitic disease.

  7. Maintenance proficiency evaluation test bank

    International Nuclear Information System (INIS)

    Maier, Loran

    2003-01-01

    The Maintenance Proficiency Evaluation Test Bank (MPETB) is an Electric Power Research Institute- (EPRJ-) operated, utility-sponsored means of developing, maintaining, and disseminating secure, high-quality written and performance maintenance proficiency tests. EPRTs charter is to ensure that all tests and test items that go into the Test Bank have been validated, screened for reliability, and evaluated to high standards of psychometric excellence. Proficiency tests of maintenance personnel.(mechanics, electricians, and instrumentation and control [I and C] technicians) are most often used to determine if an experienced employee is capable of performing maintenance tasks without further training. Such tests provide objective evidence for decisions to exempt an employee from what, for the employee, is unnecessary training. This leads to considerable savings in training costs and increased productivity because supervisors can assign personnel to tasks at which their competence is proven. The ultimate objective of proficiency evaluation is to ensure that qualified maintenance personnel are available to meet the maintenance requirements of the plant Numerous task-specific MPE tests (both written and performance) have been developed and validated using the EPRI MPE methodology by the utilities participating in the MPETB project A task-specific MPE consists of a multiple-choice written examination and a multi-step performance evaluation that can be used to assess an individual's present knowledge and skill level for a given maintenance task. The MPETB contains MPEs and test items for the mechanical, electrical, and I and C classifications that are readily available to participating utilities. Presently, utilities are placing emphasis on developing MPEs to evaluate outage-related maintenance tasks that demonstrate the competency and qualifications of plant and contractor personnel before the start of outage work. Utilities are also using the MPE methodology and process to

  8. Proposal of a framework for evaluating military surveillance systems for early detection of outbreaks on duty areas

    Directory of Open Access Journals (Sweden)

    Webber Daniel

    2008-04-01

    Full Text Available Abstract Background In recent years a wide variety of epidemiological surveillance systems have been developed to provide early identification of outbreaks of infectious disease. Each system has had its own strengths and weaknesses. In 2002 a Working Group of the Centers for Disease Control and Prevention (CDC produced a framework for evaluation, which proved suitable for many public health surveillance systems. However this did not easily adapt to the military setting, where by necessity a variety of different parameters are assessed, different constraints placed on the systems, and different objectives required. This paper describes a proposed framework for evaluation of military syndromic surveillance systems designed to detect outbreaks of disease on operational deployments. Methods The new framework described in this paper was developed from the cumulative experience of British and French military syndromic surveillance systems. The methods included a general assessment framework (CDC, followed by more specific methods of conducting evaluation. These included Knowledge/Attitude/Practice surveys (KAP surveys, technical audits, ergonomic studies, simulations and multi-national exercises. A variety of military constraints required integration into the evaluation. Examples of these include the variability of geographical conditions in the field, deployment to areas without prior knowledge of naturally-occurring disease patterns, the differences in field sanitation between locations and over the length of deployment, the mobility of military forces, turnover of personnel, continuity of surveillance across different locations, integration with surveillance systems from other nations working alongside each other, compatibility with non-medical information systems, and security. Results A framework for evaluation has been developed that can be used for military surveillance systems in a staged manner consisting of initial, intermediate and final

  9. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    Science.gov (United States)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  10. Student Drug Testing and the Surveillance School Economy: An Analysis of Media Representation and Policy Transfer in Australian Schools

    Science.gov (United States)

    Taylor, Emmeline

    2018-01-01

    Anxieties relating to the health, safety and security of schoolchildren have been met with a variety of surveillance apparatus in schools internationally. Drawing on findings from a content analysis of newspaper reports relating to drug testing in Australian schools, this article seeks to excavate the ways in which the media shapes, informs,…

  11. Emergency Diesel Generation System Surveillance Test Policy Optimization Through Genetic Algorithms Using Non-Periodic Intervention Frequencies and Seasonal Constraints

    International Nuclear Information System (INIS)

    Lapa, Celso M.F.; Pereira, Claudio M.N.A.; Frutuoso e Melo, P.F.

    2002-01-01

    Nuclear standby safety systems must frequently, be submitted to periodic surveillance tests. The main reason is to detect, as soon as possible, the occurrence of unrevealed failure states. Such interventions may, however, affect the overall system availability due to component outages. Besides, as the components are demanded, deterioration by aging may occur, penalizing again the system performance. By these reasons, planning a good surveillance test policy implies in a trade-off between gains and overheads due to the surveillance test interventions. In order maximize the systems average availability during a given period of time, it has recently been developed a non-periodic surveillance test optimization methodology based on genetic algorithms (GA). The fact of allowing non-periodic tests turns the solution space much more flexible and schedules can be better adjusted, providing gains in the overall system average availability, when compared to those obtained by an optimized periodic tests scheme. The optimization problem becomes, however, more complex. Hence, the use of a powerful optimization technique, such as GAs, is required. Some particular features of certain systems can turn it advisable to introduce other specific constraints in the optimization problem. The Emergency Diesel Generation System (EDGS) of a Nuclear Power Plant (N-PP) is a good example for demonstrating the introduction of seasonal constraints in the optimization problem. This system is responsible for power supply during an external blackout. Therefore, it is desirable during periods of high blackout probability to maintain the system availability as high as possible. Previous applications have demonstrated the robustness and effectiveness of the methodology. However, no seasonal constraints have ever been imposed. This work aims at investigating the application of such methodology in the Angra-II Brazilian NPP EDGS surveillance test policy optimization, considering the blackout probability

  12. Test and evaluation capabilities at NAVELEXCEN Charleston

    Energy Technology Data Exchange (ETDEWEB)

    Stalvey, T.W.; Anderson, G.B.; Hinson, T.L. [Naval Electronic Systems Engineering Center, Charleston, SC (United States)

    1993-12-31

    The Environmental Systems and Instrumentation Engineering Department is located within the Special Programs Directorate of the Naval Electronic Systems Engineering Center (NAVELEXCEN Charleston). This Center is an echelon 4 Command under the Naval Command Control and Ocean Surveillance Center, San Diego (NCCOSC). NCCOSC is an echelon 3 Command under the Space and Warfare Systems Command (SPAWAR) which is located in Washington DC. Radiation Detection, Indication and Computation (RDIAC) equipment life-cycle management for the entire Navy falls under the auspices of the Naval Sea Systems Command (SEA 04R). The RADIAC Program provides centralized management for the execution of research, development, test, evaluation, maintenance, procurement, allowance, and equipment support for all Navy RADIAC instrumentation and assigned special monitoring equipments. RADIAC equipment is used throughout the Navy to support various functions associated with radioactivity, potential contamination, and personnel exposure to sources of ionizing radiation. Common sources in today`s Navy include nuclear reactors, nuclear weapons, industrial radiography, and nuclear medicine. Types of radiation includes gamma, x-ray, alpha, and beta.

  13. Nuclear explosives testing readiness evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Valk, T.C.

    1993-09-01

    This readiness evaluation considers hole selection and characterization, verification, containment issues, nuclear explosive safety studies, test authorities, event operations planning, canister-rack preparation, site preparation, diagnostic equipment setup, device assembly facilities and processes, device delivery and insertion, emplacement, stemming, control room activities, readiness briefing, arming and firing, test execution, emergency response and reentry, and post event analysis to include device diagnostics, nuclear chemistry, and containment. This survey concludes that the LLNL program and its supporting contractors could execute an event within six months of notification, and a second event within the following six months, given the NET group`s evaluation and the following three restraints: (1) FY94 (and subsequent year) funding is essentially constant with FY93, (2) Preliminary work for the initial event is completed to the historical sic months status, (3) Critical personnel, currently working in dual use technologies, would be recallable as needed.

  14. Evaluating the feasibility and participants' representativeness of an online nationwide surveillance system for influenza in France.

    Directory of Open Access Journals (Sweden)

    Marion Debin

    Full Text Available The increasing Internet coverage and the widespread use of digital devices offer the possibility to develop new digital surveillance systems potentially capable to provide important aid to epidemiological and public health monitoring and research. In France, a new nationwide surveillance system for influenza-like illness, GrippeNet.fr, was introduced since the 2011/2012 season based on an online participatory mechanism and open to the general population. We evaluate the recruitment and participation of users to the first pilot season with respect to similar efforts in Europe to assess the feasibility of establishing a participative network of surveillance in France. We further investigate the representativeness of the GrippeNet.fr population along a set of indicators on geographical, demographic, socio-economic and health aspects. Participation was widespread in the country and with rates comparable to other European countries with partnered projects running since a longer time. It was not representative of the general population in terms of age and gender, however all age classes were represented, including the older classes (65+ years old, generally less familiar with the digital world, but considered at high risk for influenza complications. Once adjusted on demographic indicators, the GrippeNet.fr population is found to be more frequently employed, with a higher education level and vaccination rate with respect to the general population. A similar propensity to commute for work to different regions was observed, and no significant difference was found for asthma and diabetes. Results show the feasibility of the system, provide indications to inform adjusted epidemic analyses, and highlight the presence of specific population groups that need to be addressed by targeted communication strategies to achieve a higher representativeness in the following seasons.

  15. Evaluation of Electronic Healthcare Databases for Post-Marketing Drug Safety Surveillance and Pharmacoepidemiology in China.

    Science.gov (United States)

    Yang, Yu; Zhou, Xiaofeng; Gao, Shuangqing; Lin, Hongbo; Xie, Yanming; Feng, Yuji; Huang, Kui; Zhan, Siyan

    2018-01-01

    Electronic healthcare databases (EHDs) are used increasingly for post-marketing drug safety surveillance and pharmacoepidemiology in Europe and North America. However, few studies have examined the potential of these data sources in China. Three major types of EHDs in China (i.e., a regional community-based database, a national claims database, and an electronic medical records [EMR] database) were selected for evaluation. Forty core variables were derived based on the US Mini-Sentinel (MS) Common Data Model (CDM) as well as the data features in China that would be desirable to support drug safety surveillance. An email survey of these core variables and eight general questions as well as follow-up inquiries on additional variables was conducted. These 40 core variables across the three EHDs and all variables in each EHD along with those in the US MS CDM and Observational Medical Outcomes Partnership (OMOP) CDM were compared for availability and labeled based on specific standards. All of the EHDs' custodians confirmed their willingness to share their databases with academic institutions after appropriate approval was obtained. The regional community-based database contained 1.19 million people in 2015 with 85% of core variables. Resampled annually nationwide, the national claims database included 5.4 million people in 2014 with 55% of core variables, and the EMR database included 3 million inpatients from 60 hospitals in 2015 with 80% of core variables. Compared with MS CDM or OMOP CDM, the proportion of variables across the three EHDs available or able to be transformed/derived from the original sources are 24-83% or 45-73%, respectively. These EHDs provide potential value to post-marketing drug safety surveillance and pharmacoepidemiology in China. Future research is warranted to assess the quality and completeness of these EHDs or additional data sources in China.

  16. Improving the space surveillance telescope's performance using multi-hypothesis testing

    Energy Technology Data Exchange (ETDEWEB)

    Chris Zingarelli, J.; Cain, Stephen [Air Force Institute of Technology, 2950 Hobson Way, Bldg 641, Wright Patterson AFB, OH 45433 (United States); Pearce, Eric; Lambour, Richard [Lincoln Labratory, Massachusetts Institute of Technology, 244 Wood Street, Lexington, MA 02421 (United States); Blake, Travis [Defense Advanced Research Projects Agency, 675 North Randolph Street Arlington, VA 22203 (United States); Peterson, Curtis J. R., E-mail: John.Zingarelli@afit.edu [United States Air Force, 1690 Air Force Pentagon, Washington, DC 20330 (United States)

    2014-05-01

    The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only tests whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy.

  17. [The Brazilian National Health Surveillance Agency performance evaluation at the management contract model].

    Science.gov (United States)

    Moreira, Elka Maltez de Miranda; Costa, Ediná Alves

    2010-11-01

    The Brazilian National Health Surveillance Agency (Anvisa) is supervised by the Ministry of Health by means of a management contract, a performance evaluation tool. This case study was aimed at describing and analyzing Anvisa's performance evaluation model based on the agency's institutional purpose, according to the following analytical categories: the management contract formalization, evaluation tools, evaluators and institutional performance. Semi-structured interviews and document analysis revealed that Anvisa signed only one management contract with the Ministry of Health in 1999, updated by four additive terms. The Collegiate Board of Directors and the Advisory Center for Strategic Management play the role of Anvisa's internal evaluators and an Assessing Committee, comprising the Ministry of Health, constitutes its external evaluator. Three phases were identified in the evaluation model: the structuring of the new management model (1999-2000), legitimation regarding the productive segment (2001-2004) and widespread legitimation (2005). The best performance was presented in 2000 (86.05%) and the worst in 2004 (40.00%). The evaluation model was shown to have contributed little towards the agency's institutional purpose and the effectiveness measurement of the implemented actions.

  18. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (Capsule 2) of Ulchin Nuclear Power Plant Unit 4

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2007-04-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin Unit 4 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.306E+18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.918 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.615E+18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 8.478E+18 and 1.673E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin Unit 4 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  19. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (CAPSULE 2) of Ulchin Nuclear Power Plant Unit 3

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2006-12-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.674E 18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.920 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.913E 18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 9.249E 18 and 1.834E 19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  20. Experience gained with the development of a performance test program for the monitoring and surveillance systems in the Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Arestin, M.L.

    1988-01-01

    The monitoring and surveillance system for Embalse nuclear power plant are presented. The reactor, the nuclear fuel management, the equipments from monitoring and surveillance system, the activities developed by the AIEA experts in each mission of this test program and the management of the components for this test program in Argentine are described. (E.G.) [pt

  1. Infection with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance--Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2012-2015.

    Science.gov (United States)

    Huang, Jennifer Y; Henao, Olga L; Griffin, Patricia M; Vugia, Duc J; Cronquist, Alicia B; Hurd, Sharon; Tobin-D'Angelo, Melissa; Ryan, Patricia; Smith, Kirk; Lathrop, Sarah; Zansky, Shelley; Cieslak, Paul R; Dunn, John; Holt, Kristin G; Wolpert, Beverly J; Patrick, Mary E

    2016-04-15

    To evaluate progress toward prevention of enteric and foodborne illnesses in the United States, the Foodborne Diseases Active Surveillance Network (FoodNet) monitors the incidence of laboratory-confirmed infections caused by nine pathogens transmitted commonly through food in 10 U.S. sites. This report summarizes preliminary 2015 data and describes trends since 2012. In 2015, FoodNet reported 20,107 confirmed cases (defined as culture-confirmed bacterial infections and laboratory-confirmed parasitic infections), 4,531 hospitalizations, and 77 deaths. FoodNet also received reports of 3,112 positive culture-independent diagnostic tests (CIDTs) without culture-confirmation, a number that has markedly increased since 2012. Diagnostic testing practices for enteric pathogens are rapidly moving away from culture-based methods. The continued shift from culture-based methods to CIDTs that do not produce the isolates needed to distinguish between strains and subtypes affects the interpretation of public health surveillance data and ability to monitor progress toward prevention efforts. Expanded case definitions and strategies for obtaining bacterial isolates are crucial during this transition period.

  2. Can surveillance systems identify and avert adverse drug events? A prospective evaluation of a commercial application.

    Science.gov (United States)

    Jha, Ashish K; Laguette, Julia; Seger, Andrew; Bates, David W

    2008-01-01

    Computerized monitors can effectively detect and potentially prevent adverse drug events (ADEs). Most monitors have been developed in large academic hospitals and are not readily usable in other settings. We assessed the ability of a commercial program to identify and prevent ADEs in a community hospital. and Measurement We prospectively evaluated the commercial application in a community-based hospital. We examined the frequency and types of alerts produced, how often they were associated with ADEs and potential ADEs, and the potential financial impact of monitoring for ADEs. Among 2,407 patients screened, the application generated 516 high priority alerts. We were able to review 266 alerts at the time they were generated and among these, 30 (11.3%) were considered substantially important to warrant contacting the physician caring for the patient. These 30 alerts were associated with 4 ADEs and 11 potential ADEs. In all 15 cases, the responsible physician was unaware of the event, leading to a change in clinical care in 14 cases. Overall, 23% of high priority alerts were associated with an ADE (95% confidence interval [CI] 12% to 34%) and another 15% were associated with a potential ADE (95% CI 6% to 24%). Active surveillance used approximately 1.5 hours of pharmacist time daily. A commercially available, computer-based ADE detection tool was effective at identifying ADEs. When used as part of an active surveillance program, it can have an impact on preventing or ameliorating ADEs.

  3. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013.

    Science.gov (United States)

    Condell, Orla; Midgley, Sofie; Christiansen, Claus Bohn; Chen, Ming; Chen Nielsen, Xiaohui; Ellermann-Eriksen, Svend; Mølvadgaard, Mette; Schønning, Kristian; Vermedal Hoegh, Silje; Andersen, Peter Henrik; Voldstedlund, Marianne; Fischer, Thea Kølsen

    2016-05-05

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory-confirmed cases, clinical information was available for 63.1% (903/1,430). Primary diagnostic results were available after a median of 1.4 days, typing results after 17 days, detailed clinical information after 33 days. The large number of samples typed demonstrated continued monitoring of EV-circulation in Denmark. The system could be strengthened by increasing the collection of supplementary faecal specimens, improving communication with primary diagnostic laboratories, adapting the laboratory typing methodology and collecting clinical information with electronic forms.

  4. A study on assessment methodology of surveillance test interval and Allowed Outage Time

    International Nuclear Information System (INIS)

    Che, Moo Seong; Cheong, Chang Hyeon; Ryu, Yeong Woo; Cho, Jae Seon; Heo, Chang Wook; Kim, Do Hyeong; Kim, Joo Yeol; Kim, Yun Ik; Yang, Hei Chang

    1997-07-01

    Objectives of this study is the development of methodology by which assesses the optimization of Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korean nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches are performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method. In the second year of this study, the sensitivity analyses about the failure factors of the components are performed in the bases of the assessment methodologies of the first study, the interaction modeling of the STI and AOT is quantified. And the reliability assessment methodology about the diesel generator is reviewed and applied to the PSA code

  5. A study on assessment methodology of surveillance test interval and allowed outage time

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chang Hyun; You, Young Woo; Cho, Jae Seon; Huh, Chang Wook; Kim, Do Hyoung; Kim, Ju Youl; Kim, Yoon Ik; Yang, Hui Chang; Park, Kang Min [Seoul National Univ., Seoul (Korea, Republic of)

    1998-03-15

    The objectives of this study is the development of methodology by which assesses the optimization of Surveillance Test Internal(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korean nuclear power plant safety. In this study, the survey about the assessment methodologies, modelings and results performed by domestic and international researches are performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method. The sensitivity analyses about the failure factors of the components are performed in the bases of the and AOT is quantified. And the reliability assessment methodology about the diesel generator is reviewed and applied to the PSA code. The qualitative assessment for the STI/AOR of RPS/ESFAS assured safety the most important system in the nuclear power plant are performed.

  6. A study on assessment methodology of surveillance test interval and Allowed Outage Time

    Energy Technology Data Exchange (ETDEWEB)

    Che, Moo Seong; Cheong, Chang Hyeon; Ryu, Yeong Woo; Cho, Jae Seon; Heo, Chang Wook; Kim, Do Hyeong; Kim, Joo Yeol; Kim, Yun Ik; Yang, Hei Chang [Seoul National Univ., Seoul (Korea, Republic of)

    1997-07-15

    Objectives of this study is the development of methodology by which assesses the optimization of Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korean nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches are performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method. In the second year of this study, the sensitivity analyses about the failure factors of the components are performed in the bases of the assessment methodologies of the first study, the interaction modeling of the STI and AOT is quantified. And the reliability assessment methodology about the diesel generator is reviewed and applied to the PSA code.

  7. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance.

    Directory of Open Access Journals (Sweden)

    Sean C Murphy

    Full Text Available Nucleic acid testing (NAT for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal external quality assurance (EQA program provides validation for the assays in use. Here, we report results of an EQA exercise for malaria NAT assays. Among five centers conducting controlled human malaria infection trials, all centers achieved 100% specificity and demonstrated limits of detection consistent with each laboratory's pre-stated expectations. Quantitative bias of reported results compared to expected results was generally <0.5 log10 parasites/mL except for one laboratory where the EQA effort identified likely reasons for a general quantitative shift. The within-laboratory variation for all assays was low at <10% coefficient of variation across a range of parasite densities. Based on this study, we propose to create a Molecular Malaria Quality Assessment program that fulfills the need for EQA of malaria NAT assays worldwide.

  8. Risk factors for changing test classification in the Danish surveillance program for Salmonella in dairy herds

    DEFF Research Database (Denmark)

    Nielsen, Lennarth Ravn; Warnick, L. D.; Greiner, M.

    2007-01-01

    test positive to negative, whereas the breed and neighbor factors were not found to be important for small herds. Organic production was associated with remaining test positive, but not with becoming test positive. The results emphasize the importance of external and internal biosecurity measures....... The objective of this study was to evaluate risk factors for changing from test negative to positive, which was indicative of herds becoming infected from one quarter of the year to the next, and risk factors for changing from test positive to negative, which was indicative of herds recovering from infection...

  9. African Swine Fever in Uganda: Qualitative Evaluation of Three Surveillance Methods with Implications for Other Resource-Poor Settings.

    Science.gov (United States)

    Chenais, Erika; Sternberg-Lewerin, Susanna; Boqvist, Sofia; Emanuelson, Ulf; Aliro, Tonny; Tejler, Emma; Cocca, Giampaolo; Masembe, Charles; Ståhl, Karl

    2015-01-01

    Animal diseases impact negatively on households and on national economies. In low-income countries, this pertains especially to socio-economic effects on household level. To control animal diseases and mitigate their impact, it is necessary to understand the epidemiology of the disease in its local context. Such understanding, gained through disease surveillance, is often lacking in resource-poor settings. Alternative surveillance methods have been developed to overcome some of the hurdles obstructing surveillance. The objective of this study was to evaluate and qualitatively compare three methods for surveillance of acute infectious diseases using African swine fever in northern Uganda as an example. Report-driven outbreak investigations, participatory rural appraisals (PRAs), and a household survey using a smartphone application were evaluated. All three methods had good disease-detecting capacity, and each of them detected many more outbreaks compared to those reported to the World Organization for Animal Health during the same time period. Apparent mortality rates were similar for the three methods although highest for the report-driven outbreak investigations, followed by the PRAs, and then the household survey. The three methods have different characteristics and the method of choice will depend on the surveillance objective. The optimal situation might be achieved by a combination of the methods: outbreak detection via smartphone-based real-time surveillance, outbreak investigation for collection of biological samples, and a PRA for a better understanding of the epidemiology of the specific outbreak. All three methods require initial investments and continuous efforts. The sustainability of the surveillance system should, therefore, be carefully evaluated before making such investments.

  10. African swine fever in Uganda: qualitative evaluation of three surveillance methods with implications for other resource-poor settings

    Directory of Open Access Journals (Sweden)

    Erika eChenais

    2015-10-01

    Full Text Available Animal diseases impact negatively on households and on national economies. In low-income countries this pertains especially to socio-economic effects on household level. To control animal diseases and mitigate their impact, it is necessary to understand the epidemiology of the disease in its local context. Such understanding, gained through disease surveillance, is often lacking in resource-poor settings. Alternative surveillance methods have been developed to overcome some of the hurdles obstructing surveillance. The objective of this study was to evaluate and qualitatively compare three methods for surveillance of acute infectious diseases using African swine fever (ASF in northern Uganda as an example. Report-driven outbreak investigations, participatory rural appraisals (PRA, and a household survey using a smartphone application were evaluated. All three methods had good disease-detecting capacity, each of them detected many more outbreaks compared to those reported to the World Organization for Animal Health (OIE during the same time period. Apparent mortality rates were similar for the three methods although highest for the report-driven outbreak investigations, followed by the PRAs, and then the household survey. The three methods have different characteristics and the method of choice will depend on the surveillance objective. The optimal situation might be achieved by a combination of the methods: outbreak detection via smartphone-based real-time surveillance, outbreak investigation for collection of biological samples, and a PRA for a better understanding of the epidemiology of the specific outbreak. All three methods require initial investments and continuous efforts. The sustainability of the surveillance system should therefore be carefully evaluated before making such investments.

  11. Evaluating the RELM Test Results

    Directory of Open Access Journals (Sweden)

    Michael K. Sachs

    2012-01-01

    Full Text Available We consider implications of the Regional Earthquake Likelihood Models (RELM test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for tornadoes. We utilize a “skill score” based on the forecast scores λfi of occurrence of the test earthquakes. A perfect forecast would have λfi=1, and a random (no skill forecast would have λfi=2.86×10-3. The best forecasts (largest value of λfi for the 31 earthquakes had values of λfi=1.24×10-1 to λfi=5.49×10-3. The best mean forecast for all earthquakes was λ̅f=2.84×10-2. The best forecasts are about an order of magnitude better than random forecasts. We discuss the earthquakes, the forecasts, and alternative methods of evaluation of the performance of RELM forecasts. We also discuss the relative merits of alarm-based versus probability-based forecasts.

  12. Analysis of the surveillance test data on irradiation embrittlement of the reactor pressure vessel steels in LWRs

    International Nuclear Information System (INIS)

    Lee, Gyoeng Geun; Kwon, Jun Hyun

    2010-11-01

    The surveillance test data in Korean LWRs were analyzed from a viewpoint of materials science. TTS change with the neutron irradiation were compared to the model values of the RG1.99/2 and NUREG/CR-6551. The model values of TTS were higher than the actual values of TTS. It was impossible to find a relationship between TTS and neutron fluence in weld data. The correlation of the increase in YS (yield strength) and TTS with neutron irradiation was also investigated. Like the result of TTS change, the YS/TTS showed the correlations in plate/forgings metals, however no correlation in weld metals. The data were similar to Odette's result about US surveillance tests. From the empirical relationships, the TTS curve change could be predicted using the CVN test result of the unirradiated specimen and the change in YS with neutron irradiation of the specimen

  13. Evaluating the use of cell phone messaging for community Ebola syndromic surveillance in high risked settings in Southern Sierra Leone.

    Science.gov (United States)

    Jia, Kangbai; Mohamed, Koroma

    2015-09-01

    Most underdeveloped countries do not meet core disease outbreak surveillance because of the lack of human resources, laboratory and infrastructural facilities. The use of cell phone technology for disease outbreak syndromic surveillance is a new phenomenon in Sierra Leone despite its successes in other developing countries like Sri Lanka. In this study we set to evaluate the effectiveness of using cell phone technology for Ebola hemorrhagic fever syndromic surveillance in a high risked community in Sierra Leone. This study evaluated the effectiveness of using cell phone messaging (text and calls) for community Ebola hemorrhagic fever syndromic surveillance in high risked community in southern Sierra Leone. All cell phone syndromic surveillance data used for this study was reported as cell phone alert messages-texts and voice calls; by the Moyamba District Health Management Team for both Ebola hemorrhagic fever suspect and mortalities. We conducted a longitudinal data analysis of the monthly cumulative confirmed Ebola hemorrhagic fever cases and mortalities collected by both the traditional sentinel and community cell phone syndromic surveillance from August 2014 to October 2014. A total of 129 and 49 Ebola hemorrhagic fever suspect and confirmed cases respectively were recorded using the community Ebola syndromic surveillance cell phone alert system by the Moyamba District Health Management Team in October 2014. The average number of Ebola hemorrhagic fever suspects and confirmed cases for October 2014 were 4.16 (Std.dev 3.76) and 1.58 (Std.dev 1.43) respectively. Thirty-four percent (n=76) of the community Ebola syndromic surveillance cell phone alerts that were followed-up within 24 hours reported Ebola hemorrhagic fever suspect cases while 65.92% (n=147) reported mortality. Our study suggests some form of underreporting by the traditional sentinel Ebola hemorrhagic fever disease surveillance system in Moyamba District southern Sierra Leone for August

  14. Evaluation of the Components of the North Carolina Syndromic Surveillance System Heat Syndrome Case Definition.

    Science.gov (United States)

    Harduar Morano, Laurel; Waller, Anna E

    To improve heat-related illness surveillance, we evaluated and refined North Carolina's heat syndrome case definition. We analyzed North Carolina emergency department (ED) visits during 2012-2014. We evaluated the current heat syndrome case definition (ie, keywords in chief complaint/triage notes or International Classification of Diseases, Ninth Revision, Clinical Modification [ ICD-9-CM] codes) and additional heat-related inclusion and exclusion keywords. We calculated the positive predictive value and sensitivity of keyword-identified ED visits and manually reviewed ED visits to identify true positives and false positives. The current heat syndrome case definition identified 8928 ED visits; additional inclusion keywords identified another 598 ED visits. Of 4006 keyword-identified ED visits, 3216 (80.3%) were captured by 4 phrases: "heat ex" (n = 1674, 41.8%), "overheat" (n = 646, 16.1%), "too hot" (n = 594, 14.8%), and "heatstroke" (n = 302, 7.5%). Among the 267 ED visits identified by keyword only, a burn diagnosis or the following keywords resulted in a false-positive rate >95%: "burn," "grease," "liquid," "oil," "radiator," "antifreeze," "hot tub," "hot spring," and "sauna." After applying the revised inclusion and exclusion criteria, we identified 9132 heat-related ED visits: 2157 by keyword only, 5493 by ICD-9-CM code only, and 1482 by both (sensitivity = 27.0%, positive predictive value = 40.7%). Cases identified by keywords were strongly correlated with cases identified by ICD-9-CM codes (rho = .94, P definition through the use of additional inclusion and exclusion criteria substantially improved the accuracy of the surveillance system. Other jurisdictions may benefit from refining their heat syndrome case definition.

  15. Are the current notification criteria for Lyme borreliosis in Norway suitable? Results of an evaluation of Lyme borreliosis surveillance in Norway, 1995–2013

    Directory of Open Access Journals (Sweden)

    Emily MacDonald

    2016-08-01

    Full Text Available Abstract Background The approach to surveillance of Lyme borreliosis varies between countries, depending on the purpose of the surveillance system and the notification criteria used, which prevents direct comparison of national data. In Norway, Lyme borreliosis is notifiable to the Surveillance System for Communicable Diseases (MSIS. The current notification criteria include a combination of clinical and laboratory results for borrelia infection (excluding Erythema migrans but there are indications that these criteria are not followed consistently by clinicians and by laboratories. Therefore, an evaluation of Lyme borreliosis surveillance in Norway was conducted to describe the purpose of the system and to assess the suitability of the current notification criteria in order to identify areas for improvement. Methods The CDC Guidelines for Evaluation of Surveillance Systems were used to develop the assessment of the data quality, representativeness and acceptability of MSIS for surveillance of Lyme borreliosis. Data quality was assessed through a review of data from 1996 to 2013 in MSIS and a linkage of MSIS data from 2008 to 2012 with data from the Norwegian Patient Registry (NPR. Representativeness and acceptability were assessed through a survey sent to 23 diagnostic laboratories. Results Completeness of key variables for cases reported to MSIS was high, except for geographical location of exposureThe NPR-MSIS linkage identified 1047 cases in both registries, while 363 were only reported to MSIS and 3914 were only recorded in NPR. A higher proportion of cases found in both registries were recorded as neuroborreliosis in MSIS (84.4 % than those cases found only in MSIS (20.1 %. The trend (average yearly increase or decrease in reported cases of neuroborreliosis in MSIS was not significantly different from the trend for all other clinical manifestations recorded in MSIS in negative binomial regression (p = 0.3. The 16 surveyed laboratories

  16. Evaluation of sanitary consequences of Chernobylsk accident in France. Epidemiological surveillance plan, state of knowledge, risks evaluation and perspectives

    International Nuclear Information System (INIS)

    Verger, P.; Cherie-Challine, L.

    2000-12-01

    This report jointly written by IPSN and InVS, reviews the sanitary consequences in France of the Chernobyl accident, which occurred in 1986. The first point is dedicated to a short presentation of the knowledge relative to the sanitary consequences of the Chernobyl accident in the high contaminated countries and to the risk factors of the thyroid cancer. Secondly, this report describes the main systems of epidemiological surveillance of health implemented in France in 1986 and in 1999, as well as the data of the incidence and mortality of thyroid cancer observed in France since 1975. In addition, this report presents an analysis of the risk of thyroid cancer related to radioactive contamination in France, for young people of less than 15 years of age who where living in 1986 in the highest contaminated areas of France (Eastern territories). For this purpose, the theoretical number of thyroid cancers in excess is evaluated for this population, on the basis of different available risk model. Finally starting from the results of risk assessment, there is a discussion about the relevance and the feasibility of different epidemiological methods in view of answering the questions related to the sanitary consequences of the Chernobyl accident. In conclusion, this report recommends to reinforce the surveillance of thyroid cancer in France. (author)

  17. SOA-surveillance Nederland

    NARCIS (Netherlands)

    Rijlaarsdam J; Bosman A; Laar MJW van de; CIE

    2000-01-01

    In May 1999 a working group was started to evaluate the current surveillance systems for sexually transmitted diseases (STD) and to make suggestions for a renewed effective and efficient STD surveillance system in the Netherlands. The surveillance system has to provide insight into the prevalence

  18. Appropriateness of endoscopic surveillance recommendations in organised colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Senore, Carlo; Turrin, Anna; Mantellini, Paola; Visioli, Carmen Beatriz; Naldoni, Carlo; Sassoli De' Bianchi, Priscilla; Fedato, Chiara; Anghinoni, Emanuela; Zappa, Marco; Hassan, Cesare

    2016-11-01

    To assess the appropriateness of recommendations for endoscopic surveillance in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). 74 Italian CRC screening programmes provided aggregated data on the recommendations given after FIT-positive colonoscopies in 2011 and 2013. Index colonoscopies were divided into negative/no adenoma and low- risk, intermediate-risk and high-risk adenomas. Postcolonoscopy recommendations included a return to screening (FIT after 2 years or 5 years), an endoscopic surveillance after 6 months or after 1 year, 3 years or 5 years, surgery or other. We assessed the deviation from the postcolonoscopy recommendations of the European Guidelines in 2011 and 2013 and the correlation between overuse of endoscopic surveillance in 2011 and the process indicators associated with the endoscopic workload in 2013. 49 704 postcolonoscopy recommendations were analysed. High-risk, intermediate-risk and low-risk adenomas, and no adenomas were reported in 5.9%, 19.3%, 15.3% and 51.5% of the cases, respectively. Endoscopic surveillance was inappropriately recommended in 67.4% and 7%, respectively, of cases with low-risk and no adenoma. Overall, 37% of all endoscopic surveillance recommendations were inappropriate (6696/17 860). Overuse of endoscopic surveillance was positively correlated with the extension of invitations (correlation coefficient (cc) 0.29; p value 0.03) and with compliance with post-FIT+ colonoscopy (cc 0.25; p value 0.05), while it was negatively correlated with total colonoscopy waiting times longer than 60 days (cc -0.26; p value 0.05). In organised screening programmes, a high rate of inappropriate recommendations for patients with low risk or no adenomas occurs, affecting the demand for endoscopic surveillance by a third. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Process Evaluation of a Workers' Health Surveillance Program for Meat Processing Workers.

    Science.gov (United States)

    van Holland, Berry J; Brouwer, Sandra; de Boer, Michiel R; Reneman, Michiel F; Soer, Remko

    2017-09-01

    Objective To evaluate the implementation process of a workers' health surveillance (WHS) program in a Dutch meat processing company. Methods Workers from five plants were eligible to participate in the WHS program. The program consisted of four evaluative components and an intervention component. Qualitative and quantitative methods were used to evaluate seven process aspects. Data were gathered by interviews with stakeholders, participant questionnaires, and from registries of the company and occupational health service. Results Two recruitment strategies were used: open invitation or automatic participation. Of the 986 eligible workers, 305 participated in the program. Average reach was 53 %. Two out of five program components could not be assessed on dose delivered, dose received and fidelity. If components were assessable, 85-100 % of the components was delivered, 66-100 % of the components was received by participants, and fidelity was 100 %. Participants were satisfied with the WHS program (mean score 7.6). Contextual factors that facilitated implementation were among others societal developments and management support. Factors that formed barriers were program novelty and delayed follow-up. Conclusion The WHS program was well received by participants. Not all participants were offered the same number of program components, and not all components were performed according to protocol. Deviation from protocol is an indication of program failure and may affect program effectiveness.

  20. Effectiveness and Cost-benefit Evaluation of a Comprehensive Workers' Health Surveillance Program for Sustainable Employability of Meat Processing Workers

    NARCIS (Netherlands)

    Holland, van Berry J.; Reneman, Michiel F; Soer, Remko; Brouwer, Sandra; de Boer, Michiel R

    Objective To evaluate the effectiveness of a comprehensive workers' health surveillance (WHS) program on aspects of sustainable employability and cost-benefit. Methods A cluster randomized stepped wedge trial was performed in a Dutch meat processing company from february 2012 until march 2015. In

  1. Effectiveness and Cost-benefit Evaluation of a Comprehensive Workers' Health Surveillance Program for Sustainable Employability of Meat Processing Workers

    NARCIS (Netherlands)

    van Holland, Berry J; Reneman, Michiel F; Soer, Remko; Brouwer, Sandra; de Boer, Michiel R

    2017-01-01

    Objective To evaluate the effectiveness of a comprehensive workers' health surveillance (WHS) program on aspects of sustainable employability and cost-benefit. Methods A cluster randomized stepped wedge trial was performed in a Dutch meat processing company from february 2012 until march 2015. In

  2. Retrospective Evaluation of Pharmacist Interventions on Use of Antimicrobials Using a Clinical Surveillance Software in a Small Community Hospital

    Directory of Open Access Journals (Sweden)

    Samuel R. Huber

    2016-10-01

    Full Text Available The Infectious Diseases Society of America and the Society for Healthcare Epidemiology of America “Guidelines for Developing an Institutional Program to Enhance Antimicrobial Stewardship” recommend the use of computer-based surveillance programs for efficient and thorough identification of potential interventions as part of an antimicrobial stewardship program (ASP. This retrospective study examined the benefit of utilizing a clinical surveillance software program to help guide antimicrobial therapy in an inpatient setting, in a small community hospital, without a formal ASP. The electronic health record (EHR was used to retrieve documentations for the following types of antibiotic interventions: culture surveillance, duplicate therapy, duration of therapy and renal dose adjustments. The numbers of interventions made during the three-month periods before and after implementation of the clinical surveillance software were compared. Antibiotic related interventions aggregated to 144 and 270 in the pre- and post-implementation time frame, respectively (p < 0.0001. The total number of antibiotic interventions overall and interventions in three of the four sub-categories increased significantly from the pre-implementation to post-implementation period. Clinical surveillance software is a valuable tool to assist pharmacists in evaluating antimicrobial therapy.

  3. Vaccine-preventable diseases: evaluation of vaccination programmes and optimisation of surveillance

    NARCIS (Netherlands)

    Maas, Nicoline van der

    2018-01-01

    The Netherlands has a National Immunisation Programme (NIP) and a seasonal influenza vaccination programme. Surveillance enables countries to monitor and assess the impact of these programmes. Dutch surveillance is coordinated by the Centre for Infectious Disease Control and consists of 5 pillars,

  4. Waste feed delivery test and evaluation plan

    Energy Technology Data Exchange (ETDEWEB)

    O' TOOLE, S.M.

    1999-09-30

    This plan documents the Waste Feed Delivery Program test and evaluation planning and implementation approach. The purpose of this document is to define and communicate the Waste Feed Delivery Program Test and Evaluation scope, objectives, planning and implementation approach.

  5. Waste feed delivery test and evaluation plan

    International Nuclear Information System (INIS)

    O'TOOLE, S.M.

    1999-01-01

    This plan documents the Waste Feed Delivery Program test and evaluation planning and implementation approach. The purpose of this document is to define and communicate the Waste Feed Delivery Program Test and Evaluation scope, objectives, planning and implementation approach

  6. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal

    Science.gov (United States)

    Dieye, Yakou; Barrett, Kelsey L.; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B.; Guinot, Philippe; de los Santos, Tala

    2017-01-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools. PMID:28972982

  7. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Directory of Open Access Journals (Sweden)

    Yakou Dieye

    2017-10-01

    Full Text Available As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16 rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7% agreed to the rapid test while 383 (32.7% agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  8. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Science.gov (United States)

    Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala

    2017-10-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  9. One Health-ness Evaluation of Cysticercosis Surveillance Design in Portugal

    Directory of Open Access Journals (Sweden)

    Ana Gloria Fonseca

    2018-03-01

    Full Text Available The increasing occurrence of human cysticercosis, a zoonotic neglected disease, is challenging the traditional prevention and control paradigm and calling for One Health (OH solutions in industrialized countries. OH solutions for health interventions are increasingly being used to capture expected and unexpected outcomes across people, animals, and the environment. The Network for Evaluation of One Health (NEOH proposes an evidence-based framework, relying on systems and mixed methods approaches to evaluate the One Health-ness. In this case study, this tool is used to evaluate the design of the Observatory of Taeniasis and Cysticercosis, as an example of intersectorial collaboration for surveillance in Portugal. The OH Initiative (drivers and expected outcomes and its system (boundaries, aim, dimensions, actors, and stakeholders were described. The different aspects of this Initiative were scored with values from 0 (=no OH approach to 1 (=perfect OH approach. The OH index was 0.31. Its OH ratio is 1.98. Overall scores were as follows: OH thinking 0.75; OH planning 0.60; OH working 0.60; OH sharing 0.35; OH learning 0.50; and systemic organization 0.50. Operational levels of the Initiative are the main strengths, indicating a comprehensive multidimensional innovative approach and transdisciplinarity. Critical issues in the supporting infrastructure were observed, related to communication, learning and organizational gaps in the project, with the evaluation being conducted as the project is being designed and implemented. The strengths and weaknesses detected may be used to refine the Initiative. This case study therefore exemplifies and supports OH assessment also for ongoing projects, at design and early implementation stages for guiding and guaranteeing an OH-oriented perspective.

  10. Evaluation of the ability of standardized supports to improve public health response to syndromic surveillance for respiratory diseases in Canada

    Directory of Open Access Journals (Sweden)

    Laura A. Rivera

    2017-02-01

    Full Text Available Abstract Background Despite widespread implementation of syndromic surveillance systems within public health agencies, previous studies of the implementation and use of these systems have indicated that the functions and responses taken in response to syndromic surveillance data vary widely according to local context and preferences. The objective of the Syndromic Surveillance Evaluation Study was to develop and implement standardized supports in local public health agencies in Ontario, Canada, and evaluate the ability of these supports to affect actions taken as part of public health communicable disease control programs. Methods Local public health agencies (LPHA in Ontario, which used syndromic surveillance based on emergency department visits for respiratory disease, were recruited and randomly allocated to the study intervention or control group. The intervention group health agencies received standardized supports in terms of a standardized aberrant event detection algorithm and a response protocol dictating steps to investigate and assess the public health significance of syndromic surveillance alerts. The control group continued with their pre-existing syndromic surveillance infrastructure and processes. Outcomes were assessed using logbooks, which collected quantitative and qualitative information about alerts received, investigation steps taken, and public health responses. The study was conducted prospectively for 15 months (October 2013 to February 2015. Results Fifteen LPHAs participated in the study (n = 9 intervention group, n = 6 control group. A total of 1,969 syndromic surveillance alerts were received by all LPHAs. Variations in the types and amount of responses varied by LPHA, in particularly differences were noted by the size of the health unit. Smaller health units had more challenges to both detect and mount a response to any alerts. LPHAs in the control group were more likely to declare alerts to have public

  11. Evaluation of a commercial rubella IgM assay for use on oral fluid samples for diagnosis and surveillance of congenital rubella syndrome and postnatal rubella.

    Science.gov (United States)

    Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G

    2006-12-01

    Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.

  12. Surveillance, Evaluation of Programmatic Management of Drug Resistant Tuberculosis (PMDT at DR-TB Centre, NITRD, New Delhi

    Directory of Open Access Journals (Sweden)

    Preeti Padda

    2018-03-01

    Full Text Available Background: PMDT was launched in 2007 in our country but drug resistant TB remains to be a public health problem. Effective surveillance is the backbone for success of any programme and true stands for PMDT. Aim & Objectives: To identify the strengths and constraints of the surveillance evaluation system. Material & Methods: A cross sectional study was conducted in January 2015 at DR-TB Centre of NITRD, New Delhi which caters to a population of 29 lacs. PMDT surveillance system was evaluated using attributes like simplicity, data quality, acceptability, positive predictive value, representativeness and timeliness defined by CDC, USA guidelines. Relevant information was collected using data abstraction form and interview with stakeholders. Data was analysed using EpiInfo 07 version. Results: Nodal officer and District TB officer are responsible for surveillance system activities of PMDT at DR-TB centre and district level, respectively. All the reports (100% were submitted on time and all the districts were reporting to DR-TB centre. 75% of TB-HIV coordinators found reporting formats to be simple but all the quarterly reports were found to be complete. Data quality was not found to be optimal. Conclusion: Private sector needs to be taken on board as they have no to minimal involvement in PMDT. For data quality improvement time to time training of medical officers and health workers should be organized.

  13. Final report for the 5th surveillance test of the reactor pressure vessel material (capsule Y) of Yonggwang Nuclear Power Plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sam Lai; Kim, ByoungChul; Chang, Kee Ok (and others)

    2006-02-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X, W and Y are 5.777E+18, 1.5371E+19, 3.7634E+19, 4.3045E+19, and 4.8662E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.953 for the 1st through 5th testing and the calculational uncertainty,7.2% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.659E+19n/cm{sup 2} based on the end of 13th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 48, 56 and 64EFPY would reach 3.625E+19, 5.293E+19, 6.127E+19 and 6.960E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the Pressurized Thermal Shock(PTS) during the operation until design life.

  14. The Evaluator Effect in Usability Tests

    DEFF Research Database (Denmark)

    Jacobsen, Niels Ebbe; Hertzum, Morten; John, Bonnie E.

    1998-01-01

    Usability tests are applied in industry to evaluate systems and in research as a yardstick for other usability evaluation methods. However, one potential threat to the reliability of usability tests has been left unaddressed: the evaluator effect. In this study, four evaluators analyzed four vide...

  15. A niching genetic algorithm applied to a nuclear power plant auxiliary feedwater system surveillance tests policy optimization

    International Nuclear Information System (INIS)

    Sacco, W.F.; Lapa, Celso M.F.; Pereira, C.M.N.A.; Oliveira, C.R.E. de

    2006-01-01

    This article extends previous efforts on genetic algorithms (GAs) applied to a nuclear power plant (NPP) auxiliary feedwater system (AFWS) surveillance tests policy optimization. We introduce the application of a niching genetic algorithm (NGA) to this problem and compare its performance to previous results. The NGA maintains a populational diversity during the search process, thus promoting a greater exploration of the search space. The optimization problem consists in maximizing the system's average availability for a given period of time, considering realistic features such as: (i) aging effects on standby components during the tests; (ii) revealing failures in the tests implies on corrective maintenance, increasing outage times; (iii) components have distinct test parameters (outage time, aging factors, etc.) and (iv) tests are not necessarily periodic. We find that the NGA performs better than the conventional GA and the island GA due to a greater exploration of the search space

  16. Duplex evaluation following femoropopliteal angioplasty and stenting: criteria and utility of surveillance.

    Science.gov (United States)

    Baril, Donald T; Marone, Luke K

    2012-07-01

    Surveillance following lower extremity bypass, carotid endarterectomy, and endovascular aortic aneurysm repair has become the standard of care at most institutions. Conversely, surveillance following lower extremity endovascular interventions is performed somewhat sporadically in part because the duplex criteria for recurrent stenoses have been ill defined. It appears that duplex surveillance after peripheral endovascular interventions, as with conventional bypass, is beneficial in identifying recurrent lesions which may preclude failure and occlusion. In-stent stenosis following superficial femoral artery angioplasty and stenting can be predicted by both peak systolic velocity and velocity ratio data as measured by duplex ultrasound. Duplex criteria have been defined to determine both ≥50% in-stent stenosis and ≥80% in-stent stenosis. Although not yet well studied, it appears that applying these criteria during routine surveillance may assist in preventing failure of endovascular interventions.

  17. Evaluating Surveillance Breast Imaging and Biopsy in Older Breast Cancer Survivors

    Directory of Open Access Journals (Sweden)

    Tracy Onega

    2012-01-01

    Full Text Available Background. Patterns of surveillance among breast cancer survivors are not well characterized and lack evidence-based practice guidelines, particularly for imaging modalities other than mammography. We characterized breast imaging and related biopsy longitudinally among breast cancer survivors in relation to women’s characteristics. Methods. Using data from a state-wide (New Hampshire breast cancer screening registry linked to Medicare claims, we examined use of mammography, ultrasound (US, magnetic resonance imaging (MRI, and biopsy among breast cancer survivors. We used generalized estimating equations (GEE to model associations of breast surveillance with women’s characteristics. Results. The proportion of women with mammography was high over the follow-up period (81.5% at 78 months, but use of US or MRI was much lower (8.0%—first follow-up window, 4.7% by 78 months. Biopsy use was consistent throughout surveillance periods (7.4%–9.4%. Surveillance was lower among older women and for those with a higher stage of diagnosis. Primary therapy was significantly associated with greater likelihood of breast surveillance. Conclusions. Breast cancer surveillance patterns for mammography, US, MRI, and related biopsy seem to be associated with age, stage, and treatment, but need a larger evidence-base for clinical recommendations.

  18. A Sensitivity Study of Human Errors in Optimizing Surveillance Test Interval (STI) and Allowed Outage Time (AOT) of Standby Safety System

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Shin, Won Ky; You, Young Woo; Yang, Hui Chang

    1998-01-01

    In most cases, the surveillance test intervals (STIs), allowed outage times (AOTS) and testing strategies of safety components in nuclear power plant are prescribed in plant technical specifications. And, in general, it is required that standby safety system shall be redundant (i.e., composed of multiple components) and these components are tested by either staggered test strategy or sequential test strategy. In this study, a linear model is presented to incorporate the effects of human errors associated with test into the evaluation of unavailability. The average unavailabilities of 1/4, 2/4 redundant systems are computed considering human error and testing strategy. The adverse effects of test on system unavailability, such as component wear and test-induced transient have been modelled. The final outcome of this study would be the optimized human error domain from 3-D human error sensitivity analysis by selecting finely classified segment. The results of sensitivity analysis show that the STI and AOT can be optimized provided human error probability is maintained within allowable range. (authors)

  19. Strontium-90 in alfalfa (Medicago sativa) around the Hanford site in southeastern Washington state: an evaluation of surveillance data

    International Nuclear Information System (INIS)

    Poston, T.M.; Jaquish, R.E.; Antonio, E.J.; Patton, G.W.

    1998-01-01

    From 1988–1994, 90 Sr concentrations in alfalfa (Medicago sativa) grown in areas receiving irrigation water from the Columbia River downstream of Hanford have exceeded concentrations observed in alfalfa grown nearby using other irrigation water sources. Surveillance data indicate that the relationship is not linked to atmospheric releases from Hanford. Attributing the apparent differences in 90 Sr concentrations to irrigation water is equivocal. Evaluations of 90 Sr in Columbia River water fail to consistently show a statistically significant (P > 0.05) contribution at locations immediately downstream of Hanford. Modeling of past 90 Sr fallout accumulation in soil indicates that the potential contribution from Hanford liquid effluents entering the Columbia River, subsequently used as irrigation water from 1972 to 1992, would account for ~ 2% of 90 Sr in soil. The remaining 98% arises from historic atomic weapons testing fallout. Radiological doses modeled for an alfalfa-cow's milk-human pathway indicate that the maximum 50 year effective dose equivalent to a standard man who consumes 270 l of milk per year was 0.9 μSv, which is < 0.03% of the 3 mSv annual dose resulting from natural sources of radiation exposure

  20. Aging evaluation of class 1E batteries: Seismic testing

    International Nuclear Information System (INIS)

    Edson, J.L.

    1990-08-01

    This report presents the results of a seismic testing program on naturally aged class 1E batteries obtained from a nuclear plant. The testing program is a Phase 2 activity resulting from a Phase 1 aging evaluation of class 1E batteries in safety systems of nuclear power plants, performed previously as a part of the US Nuclear Regulatory Commission's Nuclear Plant Aging Research Program and reported in NUREG/CR-4457. The primary purpose of the program was to evaluate the seismic ruggedness of naturally aged batteries to determine if aged batteries could have adequate electrical capacity, as determined by tests recommended by IEEE Standards, and yet have inadequate seismic ruggedness to provide needed electrical power during and after a safe shutdown earthquake (SSE) event. A secondary purpose of the program was to evaluate selected advanced surveillance methods to determine if they were likely to be more sensitive to the aging degradation that reduces seismic ruggedness. The program used twelve batteries naturally aged to about 14 years of age in a nuclear facility and tested them at four different seismic levels representative of the levels of possible earthquakes specified for nuclear plants in the United States. Seismic testing of the batteries did not cause any loss of electrical capacity. 19 refs., 29 figs., 7 tabs

  1. A Web-Based, Hospital-Wide Health Care-Associated Bloodstream Infection Surveillance and Classification System: Development and Evaluation.

    Science.gov (United States)

    Tseng, Yi-Ju; Wu, Jung-Hsuan; Lin, Hui-Chi; Chen, Ming-Yuan; Ping, Xiao-Ou; Sun, Chun-Chuan; Shang, Rung-Ji; Sheng, Wang-Huei; Chen, Yee-Chun; Lai, Feipei; Chang, Shan-Chwen

    2015-09-21

    Surveillance of health care-associated infections is an essential component of infection prevention programs, but conventional systems are labor intensive and performance dependent. To develop an automatic surveillance and classification system for health care-associated bloodstream infection (HABSI), and to evaluate its performance by comparing it with a conventional infection control personnel (ICP)-based surveillance system. We developed a Web-based system that was integrated into the medical information system of a 2200-bed teaching hospital in Taiwan. The system automatically detects and classifies HABSIs. In this study, the number of computer-detected HABSIs correlated closely with the number of HABSIs detected by ICP by department (n=20; r=.999 Psystem performed excellently with regard to sensitivity (98.16%), specificity (99.96%), positive predictive value (95.81%), and negative predictive value (99.98%). The system enabled decreasing the delay in confirmation of HABSI cases, on average, by 29 days. This system provides reliable and objective HABSI data for quality indicators, improving the delay caused by a conventional surveillance system.

  2. [Development of an index system for the comprehensive evaluation on public health emergency events surveillance system in China].

    Science.gov (United States)

    Hong, Zhiheng; Ni, Daxin; Cao, Yang; Meng, Ling; Tu, Wenxiao; Li, Leilei; Li, Qun; Jin, Lianmei

    2015-06-01

    To establish a comprehensive evaluation index system for the China Public Health Emergency Events Surveillance System (CPHEESS). A draft index system was built through literature review and under the consideration of the characteristics on CPHEESS. Delphi method was adapted to determine the final index system. The index system was divided into primary, secondary and tertiary levels. There were 4 primary indicators: System structure, Network platform, Surveillance implementation reports with Data analysis and utilization. There were 16 secondary and 70 tertiary indicators being set, with System structure including 14 tertiary indicators (accounted for 20.00%), 21 Network platforms (accounted for 30.00%). Twenty-four Surveillance implementation reports (accounted for 34.29%), 11 Data analysis and utilization (accounted for 15.71%). The average score of importance of each indicators was 4.29 (3.77-4.94), with an average coefficient variation as 0.14 (0.12-0.16). The mean Chronbach's α index was 0.84 (0.81-0.89). The adaptability of each related facilities indicator was specified. The primary indicators were set in accordance with the characteristics and goals of the surveillance systems. Secondary indicators provided key elements in the management and control of the system while the tertiary indicators were available and operative. The agreement rate of experts was high with good validity and reliability. This index system could be used for CPHEESS in future.

  3. A One Health Evaluation of the Southern African Centre for Infectious Disease Surveillance

    Directory of Open Access Journals (Sweden)

    Marie C. E. Hanin

    2018-03-01

    Full Text Available Rooted in the recognition that emerging infectious diseases occur at the interface of human, animal, and ecosystem health, the Southern African Centre for Infectious Disease Surveillance (SACIDS initiative aims to promote a trans-sectoral approach to address better infectious disease risk management in five countries of the Southern African Development Community. Nine years after SACIDS’ inception, this study aimed to evaluate the program by applying a One Health (OH evaluation framework developed by the Network for Evaluation of One Health (NEOH. The evaluation included a description of the context and the initiative, illustration of the theory of change, identification of outputs and outcomes, and assessment of the One Healthness. The latter is the sum of characteristics that defines an integrated approach and includes OH thinking, OH planning, OH working, sharing infrastructure, learning infrastructure, and systemic organization. The protocols made available by NEOH were used to develop data collection protocols and identify the study design. The framework relies on a mixed methods approach by combining a descriptive and qualitative assessment with a semi-quantitative evaluation (scoring. Data for the analysis were gathered during a document review, in group and individual interviews and in an online survey. Operational aspects (i.e., OH thinking, planning, and working were found to be balanced overall with the highest score in the planning dimension, whereas the infrastructure (learning infrastructure, systemic organization, and sharing infrastructure was high for the first two dimensions, but low for sharing. The OH index calculated was 0.359, and the OH ratio calculated was 1.495. The program was praised for its great innovative energy in a difficult landscape dominated by poor infrastructure and its ability to create awareness for OH and enthuse people for the concept; training of people and networking. Shortcomings were identified

  4. Novel Use of Flu Surveillance Data: Evaluating Potential of Sentinel Populations for Early Detection of Influenza Outbreaks.

    Science.gov (United States)

    Daughton, Ashlynn R; Velappan, Nileena; Abeyta, Esteban; Priedhorsky, Reid; Deshpande, Alina

    2016-01-01

    Influenza causes significant morbidity and mortality each year, with 2-8% of weekly outpatient visits around the United States for influenza-like-illness (ILI) during the peak of the season. Effective use of existing flu surveillance data allows officials to understand and predict current flu outbreaks and can contribute to reductions in influenza morbidity and mortality. Previous work used the 2009-2010 influenza season to investigate the possibility of using existing military and civilian surveillance systems to improve early detection of flu outbreaks. Results suggested that civilian surveillance could help predict outbreak trajectory in local military installations. To further test that hypothesis, we compare pairs of civilian and military outbreaks in seven locations between 2000 and 2013. We find no predictive relationship between outbreak peaks or time series of paired outbreaks. This larger study does not find evidence to support the hypothesis that civilian data can be used as sentinel surveillance for military installations. We additionally investigate the effect of modifying the ILI case definition between the standard Department of Defense definition, a more specific definition proposed in literature, and confirmed Influenza A. We find that case definition heavily impacts results. This study thus highlights the importance of careful selection of case definition, and appropriate consideration of case definition in the interpretation of results.

  5. Comparison of rate theory based modeling calculations with the surveillance test results of Korean light water reactors

    International Nuclear Information System (INIS)

    Lee, Gyeong Geun; Lee, Yong Bok; Kim, Min Chul; Kwon, Junh Yun

    2012-01-01

    Neutron irradiation to reactor pressure vessel (RPV) steels causes a decrease in fracture toughness and an increase in yield strength while in service. It is generally accepted that the growth of point defect cluster (PDC) and copper rich precipitate (CRP) affects radiation hardening of RPV steels. A number of models have been proposed to account for the embrittlement of RPV steels. The rate theory based modeling mathematically described the evolution of radiation induced microstructures of ferritic steels under neutron irradiation. In this work, we compared the rate theory based modeling calculation with the surveillance test results of Korean Light Water Reactors (LWRs)

  6. Surveillance of compliance with tobacco regulations in Örebro County, Sweden: a mixed methods study after the ban of test purchases.

    Science.gov (United States)

    Schölin, Lisa; Eriksson, Charli

    2012-02-15

    Tobacco has long been known to be one of the most common reasons for sickness and premature deaths in the world. An important aspect of tobacco use is the youth's access to tobacco, and surveillance visits are one way to make sure how retailers are complying with age limit in the tobacco law. In Örebro County, Sweden, a project to reinforce the tobacco legislation was carried out in 2009-2010. One part of the project was surveillance visits that were done according to three different themes, called thematic surveillance. This study is an evaluation of the results from thematic surveillance and has a mixed methods approach. The quantitative analyses concerns protocols from 217 surveillance visits, where questions were asked about three themes (self-monitoring programs; marketing; labeling of products and pricing). In addition, questionnaires filled out by six tobacco administrators who worked within the project were analyzed qualitatively by content analysis in order to study their perceptions and opinions of the project. This study shows that half of the visited retailers had self-monitoring programs. Lack of self-monitoring programs was significantly more common in smaller stores/kiosks and at restaurants. Further, the tobacco administrators who worked within the project perceived thematic surveillance as a good method for accomplishing better structure in surveillance work, but not as effective as purchase attempts (mystery shopping). Thematic surveillance was perceived as positive and the method was also regarded to be a good way to work with surveillance. However, the method could be developed further for optimal use and better effect at the retailers. It is clear that people who work with tobacco prevention at the local level in Örebro County want to use purchase attempts as a surveillance method, and that they believe that purchase attempts is the best way to make sure if store comply with the tobacco law.

  7. The evaluation of the Chernobyl reactor accident by the help of the Hungarian Surveillance of Germinal Mutations

    International Nuclear Information System (INIS)

    Czeizel, A.E.; Elek, Cs.; Susanszky, E.

    1992-01-01

    The germinal mutagenic consequences or radioactive fall-out deposition from the Chernobyl accident in Hungary was evaluated in the ongoing program on the population-based Hungarian Surveillance of Germinal Mutations. The surveillance is based on three groups of indicator conditions: 15 sentinel anomalies (indicators of germinal dominant gene mutations), Down syndrome (an indicator of germinal numerical and structural chromosomal mutations) and unidentified multiple congenital abnormalities (indicators of germinal dominant gene and chromosomal mutations). Cases with indicator conditions were selected from the material of the Hungarian Congenital Abnormality Registry. After the diagnostic accuracies were checked, familial and sporadic cases were separated and only the latter group was evaluated for evidence of new mutations. The analysis did not reveal any measurable germinal mutagenic effects of the Chernobyl reactor accident in Hungary. (author)

  8. Air surveillance

    International Nuclear Information System (INIS)

    Patton, G.W.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995)

  9. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  10. The design and evaluation of an antimicrobial resistance surveillance system for neonatal intensive care units in Iran.

    Science.gov (United States)

    Rezaei-Hachesu, Peyman; Samad-Soltani, Taha; Yaghoubi, Sajad; GhaziSaeedi, Marjan; Mirnia, Kayvan; Masoumi-Asl, Hossein; Safdari, Reza

    2018-07-01

    Neonatal intensive care units (NICUs) have complex patients in terms of their diagnoses and required treatments. Antimicrobial treatment is a common therapy for patients in NICUs. To solve problems pertaining to empirical therapy, antimicrobial stewardship programs have recently been introduced. Despite the success of these programs in terms of data collection, there is still inefficiency in terms of analyzing and reporting the data. Thus, to successfully implement these stewardship programs, the design of antimicrobial resistance (AMR) surveillance systems is recommended as a first step. As a result, this study aimed to design an AMR surveillance system for use in the NICUs in northwestern Iranian hospitals to cover these information gaps. The recommended system is compatible with the World Health Organization (WHO) guidelines. The business intelligence (BI) requirements were extracted in an interview with a product owner (PO) using a valid and reliable checklist. Following this, an AMR surveillance system was designed and evaluated in relation to user experiences via a user experience questionnaire (UEQ). Finally, an association analysis was performed on the database, and the results were reported by identifying the important multidrug resistances in the database. A customized software development methodology was proposed. The three major modules of the AMR surveillance are the data registry, dashboard, and decision support modules. The data registry module was implemented based on a three-tier architecture, and the Clinical Decision Support System (CDSS) and dashboard modules were designed based on the BI requirements of the Scrum product owner (PO). The mean values of UEQ measures were in a good range. This measures showed the suitable usability of the AMR surveillance system. Applying efficient software development methodologies allows for the systems' compatibility with users' opinions and requirements. In addition, the construction of interdisciplinary

  11. Mortuary based injury surveillance for low-mid income countries: process evaluation of pilot studies.

    Science.gov (United States)

    Kipsaina, Chebiwot; Ozanne-Smith, Joan; Bartolomeos, Kidist; Routley, Virginia

    2015-08-01

    Globally, injury is the fourth major cause of death and the third leading contributor to Disability Adjusted Life Years lost due to health conditions, with the greatest burden borne by low-middle income countries (LMICs) where injury data is scarce. In the absence of effective vital registration systems, mortuaries have been shown to provide an alternative source of cause of death information for practitioners and policy makers to establish strategic injury prevention policies and programs. This evaluation sought to assess the feasibility of implementing a standardised fatal injury data collection process to systematically collect relevant fatal injury data from mortuaries. The process evaluation is described. A manual including a one page data collection form, coding guide, data dictionary, data entry and analysis program was developed through World Health Organization and Monash University Australia collaboration, with technical advice from an International Advisory Group. The data collection component was piloted in multiple mortuaries, in five LMICs (Egypt, India, Sri-Lanka, Tanzania and Zambia). Process evaluation was based on a questionnaire completed by each country's Principal Investigator. Questionnaires were completed for data collections in urban and rural mortuaries between September 2010 and February 2011. Of the 1795 reported fatal injury cases registered in the participating mortuaries, road traffic injury accounted for the highest proportion of cases, ranging from 22% to 87%. Other causes included burns, poisoning, drowning and falls. Positive system attributes were feasibility, acceptability, usefulness, timeliness, and simplicity and data field completeness. Some limitations included short duration of the pilot studies, limited injury data collector training and apparent underreporting of cases to the medico-legal system or mortuaries. The mortuary has been shown to be a potential data source for identifying injury deaths and their circumstances

  12. Defence Test and Evaluation Roadmap

    Science.gov (United States)

    2008-01-01

    as staff move into new roles in non-T&E organisations. The majority of T&E training is conducted ‘on the job’ and staff turnover (especially with...T&E Issues / Requirements Robotic Combat Systems Determine vulnerability of emerging combat systems to anti- armour robotic systems. Evaluate...Improvised Explosive Devices (IED) Determine capability of armoured & vehicle systems to withstand IED attacks Translate threat scenarios into framework

  13. Performance Evaluations for Super-Resolution Mosaicing on UAS Surveillance Videos

    Directory of Open Access Journals (Sweden)

    Aldo Camargo

    2013-05-01

    Full Text Available Abstract Unmanned Aircraft Systems (UAS have been widely applied for reconnaissance and surveillance by exploiting information collected from the digital imaging payload. The super-resolution (SR mosaicing of low-resolution (LR UAS surveillance video frames has become a critical requirement for UAS video processing and is important for further effective image understanding. In this paper we develop a novel super-resolution framework, which does not require the construction of sparse matrices. The proposed method implements image operations in the spatial domain and applies an iterated back-projection to construct super-resolution mosaics from the overlapping UAS surveillance video frames. The Steepest Descent method, the Conjugate Gradient method and the Levenberg-Marquardt algorithm are used to numerically solve the nonlinear optimization problem for estimating a super-resolution mosaic. A quantitative performance comparison in terms of computation time and visual quality of the super-resolution mosaics through the three numerical techniques is presented.

  14. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  15. Test and Evaluation Management Guide, Fifth Edition

    National Research Council Canada - National Science Library

    Claxton, John D; Cavoli, Christina; Johnson, Collie

    2005-01-01

    This January 2005 update to the Defense Acquisition University's "Test and Evaluation Management Guide" includes updates from the Military Services, Defense Agencies, and other organizations, as well...

  16. Unexpectedly high leprosy seroprevalence detected using a random surveillance strategy in midwestern Brazil: A comparison of ELISA and a rapid diagnostic test.

    Science.gov (United States)

    Frade, Marco Andrey C; de Paula, Natália A; Gomes, Ciro M; Vernal, Sebastian; Bernardes Filho, Fred; Lugão, Helena B; de Abreu, Marilda M M; Botini, Patrícia; Duthie, Malcolm S; Spencer, John S; Soares, Rosa Castália F R; Foss, Norma T

    2017-02-01

    Leprosy diagnosis is mainly based on clinical evaluation, although this approach is difficult, especially for untrained physicians. We conducted a temporary campaign to detect previously unknown leprosy cases in midwestern Brazil and to compare the performance of different serological tests. A mobile clinic was stationed at the main bus terminal in Brasília, Brazil. Volunteers were quizzed and given a clinical exam to allow categorization as either patients, known contacts of patients or non-contacts, and blood was collected to determine anti-PGL-I and anti-LID-1 antibody titers by ELISA and by the NDO-LID rapid test. New cases of leprosy and the impact of performing this broad random surveillance strategy were evaluated. Accuracy values and concordance between the test results were evaluated among all groups. Four hundred thirty-four individuals were evaluated, and 44 (10.1%) were diagnosed with leprosy. Borderline forms were the most frequent presentation. Both tests presented higher positivity in those individuals with multibacillary disease. Serological tests demonstrated specificities arround 70% for anti-PGL-1 and anti-LID ELISA; and arround 40% for NDO-LID. Sensitivities ranged from 48 to 62%. A substantial agreement between NDO-LID and ELISA with concomitant positive results was found within leprosy patients (Kappa index = 0.79 CI95% 0.36-1.22). The unexpectedly high leprosy prevalence in this population indicates ongoing community-based exposure to Mycobacterium leprae antigens and high rates of subclinical infection. All tests showed low specificity and sensitivity values and therefore cannot be considered for use as stand-alone diagnostics. Rather, considering their positivity among MB patients and non-patients, these tests can be considered effective tools for screening and identifying individuals at high risk who might benefit from regular monitoring.

  17. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  18. A risk assessment approach to evaluating food safety based on product surveillance

    NARCIS (Netherlands)

    Notermans, S.; Nauta, M.J.; Jansen, J.; Jouve, J.L.; Mead, G.C.

    1998-01-01

    This paper outlines a risk assessment approach to food safety evaluation, which is based on testing a particular type of food, or group of similar foods, for relevant microbial pathogens. The results obtained are related to possible adverse effects on the health of consumers. The paper also gives an

  19. Evaluation of PM-10 commercial inlets for new surveillance air sampler

    International Nuclear Information System (INIS)

    Langer, G.

    1987-01-01

    The purpose of this project is to adapt an existing sampling inlet or develop a new one to collect airborne dust particles <10-μm aerodynamic equivalent diameter. These inlets are necessary to meet new EPA and DOE guidelines for surveillance of nuclear facilities

  20. Role of diagnostic tests in esophageal evaluation

    International Nuclear Information System (INIS)

    Silverstein, B.D.; Pope, C.E. II

    1980-01-01

    In the evaluation of esophageal disease, the appropriate question must be asked before the correct tests can be selected. Reflux can be demonstrated by radiologic methods, pH testing or radioisotopic techniques. Esophageal mucosal damage is best evaluated by x-ray, endoscopy, or biopsy. Chest pain is demonstrated by acid infusion or by manometry. Two algorithms are presented for the evaluation of chest pain and reflux symptoms

  1. Surveillance extension experience at WWER-440 type reactors

    International Nuclear Information System (INIS)

    Gillemot, F.; Uri, G.; Oszwald, F.; Trampus, P.

    1993-01-01

    In WWER-440 reactors, the surveillance specimens are located in accelerated irradiation positions. After 5 years, all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension has been settled in order to avoid these original program disadvantages and generate further data for plant lifetime management. This paper includes: research performed to prepare the surveillance extension programme, the evaluation method for the surveillance extension, and first results (Charpy and tensile tests). (authors). 6 refs., 12 figs., 3 tabs

  2. Surveillance extension experience at WWER-440 type reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gillemot, F; Uri, G [Budapesti Mueszaki Egyetem, Budapest (Hungary); Oszwald, F; Trampus, P

    1994-12-31

    In WWER-440 reactors, the surveillance specimens are located in accelerated irradiation positions. After 5 years, all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension has been settled in order to avoid these original program disadvantages and generate further data for plant lifetime management. This paper includes: research performed to prepare the surveillance extension programme, the evaluation method for the surveillance extension, and first results (Charpy and tensile tests). (authors). 6 refs., 12 figs., 3 tabs.

  3. Guess Who’s Not Coming to Dinner? Evaluating Online Restaurant Reservations for Disease Surveillance

    OpenAIRE

    Nsoesie, Elaine O; Buckeridge, David L; Brownstein, John S

    2014-01-01

    Background Alternative data sources are used increasingly to augment traditional public health surveillance systems. Examples include over-the-counter medication sales and school absenteeism. Objective We sought to determine if an increase in restaurant table availabilities was associated with an increase in disease incidence, specifically influenza-like illness (ILI). Methods Restaurant table availability was monitored using OpenTable, an online restaurant table reservation site. A daily sea...

  4. Incidence and Trends of Infections with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance - Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2013-2016.

    Science.gov (United States)

    Marder, Ellyn P; Cieslak, Paul R; Cronquist, Alicia B; Dunn, John; Lathrop, Sarah; Rabatsky-Ehr, Therese; Ryan, Patricia; Smith, Kirk; Tobin-D'Angelo, Melissa; Vugia, Duc J; Zansky, Shelley; Holt, Kristin G; Wolpert, Beverly J; Lynch, Michael; Tauxe, Robert; Geissler, Aimee L

    2017-04-21

    Foodborne diseases represent a substantial public health concern in the United States. CDC's Foodborne Diseases Active Surveillance Network (FoodNet) monitors cases reported from 10 U.S. sites* of laboratory-diagnosed infections caused by nine enteric pathogens commonly transmitted through food. This report describes preliminary surveillance data for 2016 on the nine pathogens and changes in incidences compared with 2013-2015. In 2016, FoodNet identified 24,029 infections, 5,512 hospitalizations, and 98 deaths caused by these pathogens. The use of culture-independent diagnostic tests (CIDTs) by clinical laboratories to detect enteric pathogens has been steadily increasing since FoodNet began surveying clinical laboratories in 2010 (1). CIDTs complicate the interpretation of FoodNet surveillance data because pathogen detection could be affected by changes in health care provider behaviors or laboratory testing practices (2). Health care providers might be more likely to order CIDTs because these tests are quicker and easier to use than traditional culture methods, a circumstance that could increase pathogen detection (3). Similarly, pathogen detection could also be increasing as clinical laboratories adopt DNA-based syndromic panels, which include pathogens not often included in routine stool culture (4,5). In addition, CIDTs do not yield isolates, which public health officials rely on to distinguish pathogen subtypes, determine antimicrobial resistance, monitor trends, and detect outbreaks. To obtain isolates for infections identified by CIDTs, laboratories must perform reflex culture † ; if clinical laboratories do not, the burden of culturing falls to state public health laboratories, which might not be able to absorb that burden as the adoption of these tests increases (2). Strategies are needed to preserve access to bacterial isolates for further characterization and to determine the effect of changing trends in testing practices on surveillance.

  5. Soil and vegetation surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, E.J.

    1995-06-01

    Soil sampling and analysis evaluates long-term contamination trends and monitors environmental radionuclide inventories. This section of the 1994 Hanford Site Environmental Report summarizes the soil and vegetation surveillance programs which were conducted during 1994. Vegetation surveillance is conducted offsite to monitor atmospheric deposition of radioactive materials in areas not under cultivation and onsite at locations adjacent to potential sources of radioactivity.

  6. Parallel island genetic algorithm applied to a nuclear power plant auxiliary feedwater system surveillance tests policy optimization

    International Nuclear Information System (INIS)

    Pereira, Claudio M.N.A.; Lapa, Celso M.F.

    2003-01-01

    In this work, we focus the application of an Island Genetic Algorithm (IGA), a coarse-grained parallel genetic algorithm (PGA) model, to a Nuclear Power Plant (NPP) Auxiliary Feedwater System (AFWS) surveillance tests policy optimization. Here, the main objective is to outline, by means of comparisons, the advantages of the IGA over the simple (non-parallel) genetic algorithm (GA), which has been successfully applied in the solution of such kind of problem. The goal of the optimization is to maximize the system's average availability for a given period of time, considering realistic features such as: i) aging effects on standby components during the tests; ii) revealing failures in the tests implies on corrective maintenance, increasing outage times; iii) components have distinct test parameters (outage time, aging factors, etc.) and iv) tests are not necessarily periodic. In our experiments, which were made in a cluster comprised by 8 1-GHz personal computers, we could clearly observe gains not only in the computational time, which reduced linearly with the number of computers, but in the optimization outcome

  7. Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method describes the use of solid-state track recorders (SSTRs) for neutron dosimetry in light-water reactor (LWR) applications. These applications extend from low neutron fluence to high neutron fluence, including high power pressure vessel surveillance and test reactor irradiations as well as low power benchmark field measurement. (1) This test method replaces Method E 418. This test method is more detailed and special attention is given to the use of state-of-the-art manual and automated track counting methods to attain high absolute accuracies. In-situ dosimetry in actual high fluence-high temperature LWR applications is emphasized. 1.2 This test method includes SSTR analysis by both manual and automated methods. To attain a desired accuracy, the track scanning method selected places limits on the allowable track density. Typically good results are obtained in the range of 5 to 800 000 tracks/cm2 and accurate results at higher track densities have been demonstrated for some cases. (2) Trac...

  8. Component evaluation testing and analysis algorithms.

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Darren M.; Merchant, Bion John

    2011-10-01

    The Ground-Based Monitoring R&E Component Evaluation project performs testing on the hardware components that make up Seismic and Infrasound monitoring systems. The majority of the testing is focused on the Digital Waveform Recorder (DWR), Seismic Sensor, and Infrasound Sensor. In order to guarantee consistency, traceability, and visibility into the results of the testing process, it is necessary to document the test and analysis procedures that are in place. Other reports document the testing procedures that are in place (Kromer, 2007). This document serves to provide a comprehensive overview of the analysis and the algorithms that are applied to the Component Evaluation testing. A brief summary of each test is included to provide the context for the analysis that is to be performed.

  9. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  10. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals

    Directory of Open Access Journals (Sweden)

    Isabel G. Trindade

    2016-09-01

    Full Text Available This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  11. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals.

    Science.gov (United States)

    Trindade, Isabel G; Machado da Silva, José; Miguel, Rui; Pereira, Madalena; Lucas, José; Oliveira, Luís; Valentim, Bruno; Barreto, Jorge; Santos Silva, Manuel

    2016-09-24

    This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  12. Foucault, surveillance, and carbon monoxide testing within stop-smoking services.

    Science.gov (United States)

    Grant, Aimee; Ashton, Kathryn; Phillips, Rhiannon

    2015-07-01

    Health professionals have adopted proactive testing for early evidence of disease. Researchers have identified that this leads to enumerated understandings and shapes behavior in productive ways. Smoking-cessation advisors regularly test clients for carbon monoxide (CO), but client views of this had not previously been explored. We interviewed 23 clients of a United Kingdom-based stop-smoking service regarding their experiences of CO testing. The majority of participants were successful quitters. We used ATLAS.ti 7 as a data-management tool during structured qualitative analysis. Our findings reveal that clients believed the results of their CO tests. Many became enumerated in their understanding, and thus placed themselves in a hierarchy with other members of their group. Almost all clients found that knowing their CO test score was motivating. We conclude that additional research is needed to understand the experiences of CO testing among clients who do not quit. © The Author(s) 2014.

  13. Surveillance testing of onsite electrical power systems, several cases of standards misinterpretation in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Recarte, I.; Cid, R. [Consejo de Seguridad Nuclear, Sor Angela de la Cruz, 3, Madrid 28016 (Spain)

    1986-02-15

    Two events related with the onsite electric Systems of Spanish nuclear power plants are discussed. The first of them is related with diesel generators, its compliance with technical specifications; with the valid test, failure classification and frequency of tests as defined in Regulatory Guide 1.108. The other problem concerns of the direct current batteries. Presently they are subject by technical specifications to testing of a discharge cycle for which they were not designed. (authors)

  14. Relapse surveillance in AFP-positive hepatoblastoma: re-evaluating the role of imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rojas, Yesenia; Vasudevan, Sanjeev A.; Nuchtern, Jed G. [Baylor College of Medicine, Pediatric Surgery Division, Michael E. DeBakey Department of Surgery, Texas Children' s Hospital, Houston, TX (United States); Guillerman, R.P. [Baylor College of Medicine, Department of Pediatric Radiology, Texas Children' s Hospital, Houston, TX (United States); Zhang, Wei [Texas Children' s Hospital, Surgical Outcomes Center, Houston, TX (United States); Thompson, Patrick A. [Baylor College of Medicine, Hematology-Oncology Division, Department of Pediatrics, Texas Children' s Cancer Center, Texas Children' s Hospital, Houston, TX (United States); University of North Carolina, Hematology-Oncology Division, Department of Pediatrics, North Carolina Children' s Hospital, Chapel Hill, NC (United States)

    2014-10-15

    Children with hepatoblastoma routinely undergo repetitive surveillance imaging, with CT scans for several years after therapy, increasing the risk of radiation-induced cancer. The purpose of this study was to determine the utility of surveillance CT scans compared to serum alpha-fetoprotein (AFP) levels for the detection of hepatoblastoma relapse. This was a retrospective study of all children diagnosed with AFP-positive hepatoblastoma from 2001 to 2011 at a single institution. Twenty-six children with hepatoblastoma were identified, with a mean age at diagnosis of 2 years 4 months (range 3 months to 11 years). Mean AFP level at diagnosis was 132,732 ng/ml (range 172.8-572,613 ng/ml). Five of the 26 children had hepatoblastoma relapse. A total of 105 imaging exams were performed following completion of therapy; 88 (84%) CT, 8 (8%) MRI, 5 (5%) US and 4 (4%) FDG PET/CT exams. A total of 288 alpha-fetoprotein levels were drawn, with a mean of 11 per child. The AFP level was elevated in all recurrences and no relapses were detected by imaging before AFP elevation. Two false-positive AFP levels and 15 false-positive imaging exams were detected. AFP elevation was found to be significantly more specific than PET/CT and CT imaging at detecting relapse. We recommend using serial serum AFP levels as the preferred method of surveillance in children with AFP-positive hepatoblastoma, reserving imaging for the early postoperative period, for children at high risk of relapse, and for determination of the anatomical site of clinically suspected recurrence. Given the small size of this preliminary study, validation in a larger patient population is warranted. (orig.)

  15. Evaluation of the National Human Immunodeficiency Virus Surveillance System for the 2011 diagnosis year.

    Science.gov (United States)

    Karch, Debra L; Chen, Mi; Tang, Tian

    2014-01-01

    In 2009, the Centers for Disease Control and Prevention completed migration of all 59 surveillance project areas (PAs) from the case-based HIV/AIDS Reporting System to the document-based Enhanced HIV/AIDS Reporting System. We conducted a PA-level assessment of Enhanced HIV/AIDS Reporting System process and outcome standards for HIV infection cases. Process standards were reported by PAs and outcome standards were calculated using standardized Centers for Disease Control and Prevention SAS code. A total of 59 PAs including 50 US states, the District of Columbia, 6 separately funded cities (Chicago, Houston, Los Angeles County, New York City, Philadelphia, and San Francisco), and 2 territories (Puerto Rico and the Virgin Islands). Cases diagnosed or reported to the PA surveillance system between January 1, 2011, and December 31, 2011, using data collected through December 2012. Process standards for death ascertainment and intra- and interstate case de-duplication; outcome standards for completeness and timeliness of case reporting, data quality, intrastate duplication rate, risk factor ascertainment, and completeness of initial CD4 and viral load reporting. Fifty-five of 59 PAs (93%) reported linking cases to state vital records death certificates during 2012, 76% to the Social Security Death Master File, and 59% to the National Death Index. Seventy percent completed monthly intrastate, and 63% completed semiannual interstate de-duplication. Eighty-three percent met the 85% or more case ascertainment standard, and 92% met the 66% or more timeliness standard; 75% met the 97% or more data quality standard; all PAs met the 5% or less intrastate duplication rate; 41% met the 85% or more risk factor ascertainment standard; 90% met the 50% or more standard for initial CD4; and 93% met the same standard for viral load reporting. Overall, 7% of PAs met all 11 process and outcome standards. Findings support the need for continued improvement in HIV surveillance activities

  16. Student Tests for Teacher Evaluation: A Critique.

    Science.gov (United States)

    Florio, David H.

    1986-01-01

    This article supports Edward Haertel's views on inappropriate use of student test scores in evaluating teachers. Tests scores may identify a few incompetent teachers, but may bring new ailments to schools. The article argues that even the system proposed by Haertal may become subject to abuse by mechanistic or autocratic administrative practices.…

  17. Testing and evaluation of light ablation decontamination

    International Nuclear Information System (INIS)

    Demmer, R.L.; Ferguson, R.L.

    1994-10-01

    This report details the testing and evaluation of light ablation decontamination. It details WINCO contracted research and application of light ablation efforts by Ames Laboratory. Tests were conducted with SIMCON (simulated contamination) coupons and REALCON (actual radioactive metal coupons) under controlled conditions to compare cleaning effectiveness, speed and application to plant process type equipment

  18. Marihuana contact test, evaluation and development

    Science.gov (United States)

    1976-02-01

    A colorimetric swab test for detecting human contact with marihuana was evaluated. The test was found to be capable of detecting only 83% of marihuana smokers immediately after smoking and was also demonstrated to be subject to a wide range of possib...

  19. Incorporating Direct Rapid Immunohistochemical Testing into Large-Scale Wildlife Rabies Surveillance

    Directory of Open Access Journals (Sweden)

    Kevin Middel

    2017-06-01

    Full Text Available Following an incursion of the mid-Atlantic raccoon variant of the rabies virus into southern Ontario, Canada, in late 2015, the direct rapid immunohistochemical test for rabies (dRIT was employed on a large scale to establish the outbreak perimeter and to diagnose specific cases to inform rabies control management actions. In a 17-month period, 5800 wildlife carcasses were tested using the dRIT, of which 307 were identified as rabid. When compared with the gold standard fluorescent antibody test (FAT, the dRIT was found to have a sensitivity of 100% and a specificity of 98.2%. Positive and negative test agreement was shown to be 98.3% and 99.1%, respectively, with an overall test agreement of 98.8%. The average cost to test a sample was $3.13 CAD for materials, and hands-on technical time to complete the test is estimated at 0.55 h. The dRIT procedure was found to be accurate, fast, inexpensive, easy to learn and perform, and an excellent tool for monitoring the progression of a wildlife rabies incursion.

  20. Bootstrap confidence intervals and bias correction in the estimation of HIV incidence from surveillance data with testing for recent infection.

    Science.gov (United States)

    Carnegie, Nicole Bohme

    2011-04-15

    The incidence of new infections is a key measure of the status of the HIV epidemic, but accurate measurement of incidence is often constrained by limited data. Karon et al. (Statist. Med. 2008; 27:4617–4633) developed a model to estimate the incidence of HIV infection from surveillance data with biologic testing for recent infection for newly diagnosed cases. This method has been implemented by public health departments across the United States and is behind the new national incidence estimates, which are about 40 per cent higher than previous estimates. We show that the delta method approximation given for the variance of the estimator is incomplete, leading to an inflated variance estimate. This contributes to the generation of overly conservative confidence intervals, potentially obscuring important differences between populations. We demonstrate via simulation that an innovative model-based bootstrap method using the specified model for the infection and surveillance process improves confidence interval coverage and adjusts for the bias in the point estimate. Confidence interval coverage is about 94–97 per cent after correction, compared with 96–99 per cent before. The simulated bias in the estimate of incidence ranges from −6.3 to +14.6 per cent under the original model but is consistently under 1 per cent after correction by the model-based bootstrap. In an application to data from King County, Washington in 2007 we observe correction of 7.2 per cent relative bias in the incidence estimate and a 66 per cent reduction in the width of the 95 per cent confidence interval using this method. We provide open-source software to implement the method that can also be extended for alternate models.

  1. Evaluation of the international standardized 24-h dietary recall methodology (GloboDiet) for potential application in research and surveillance within African settings.

    Science.gov (United States)

    Aglago, Elom Kouassivi; Landais, Edwige; Nicolas, Geneviève; Margetts, Barrie; Leclercq, Catherine; Allemand, Pauline; Aderibigbe, Olaide; Agueh, Victoire Damienne; Amuna, Paul; Annor, George Amponsah; El Ati, Jalila; Coates, Jennifer; Colaiezzi, Brooke; Compaore, Ella; Delisle, Hélène; Faber, Mieke; Fungo, Robert; Gouado, Inocent; El Hamdouchi, Asmaa; Hounkpatin, Waliou Amoussa; Konan, Amoin Georgette; Labzizi, Saloua; Ledo, James; Mahachi, Carol; Maruapula, Segametsi Ditshebo; Mathe, Nonsikelelo; Mbabazi, Muniirah; Mirembe, Mandy Wilja; Mizéhoun-Adissoda, Carmelle; Nzi, Clement Diby; Pisa, Pedro Terrence; El Rhazi, Karima; Zotor, Francis; Slimani, Nadia

    2017-06-19

    Collection of reliable and comparable individual food consumption data is of primary importance to better understand, control and monitor malnutrition and its related comorbidities in low- and middle-income countries (LMICs), including in Africa. The lack of standardised dietary tools and their related research support infrastructure remains a major obstacle to implement concerted and region-specific research and action plans worldwide. Citing the magnitude and importance of this challenge, the International Agency for Research on Cancer (IARC/WHO) launched the "Global Nutrition Surveillance initiative" to pilot test the use of a standardized 24-h dietary recall research tool (GloboDiet), validated in Europe, in other regions. In this regard, the development of the GloboDiet-Africa can be optimised by better understanding of the local specific methodological needs, barriers and opportunities. The study aimed to evaluate the standardized 24-h dietary recall research tool (GloboDiet) as a possible common methodology for research and surveillance across Africa. A consultative panel of African and international experts in dietary assessment participated in six e-workshop sessions. They completed an in-depth e-questionnaire to evaluate the GloboDiet dietary methodology before and after participating in the e-workshop. The 29 experts expressed their satisfaction on the potential of the software to address local specific needs when evaluating the main structure of the software, the stepwise approach for data collection and standardisation concept. Nevertheless, additional information to better describe local foods and recipes, as well as particular culinary patterns (e.g. mortar pounding), were proposed. Furthermore, food quantification in shared-plates and -bowls eating situations and interviewing of populations with low literacy skills, especially in rural settings, were acknowledged as requiring further specific considerations and appropriate solutions. An overall

  2. Development of the plant life management technology for RPV steels [ - Current status of surveillance test specimen reconstitution program -

    International Nuclear Information System (INIS)

    Kazunobu, Sakamoto; Eliichiro, Otsuka; Yoshiaki, Oka; Kosei, Taguchi; Michiyoshi, Yamamoto

    2001-01-01

    In order to develop the reconstitution technology to standardize surveillance test specimen reconstitution practices to deal with the extended service life of reactor pressure vessels, the Japan Power Engineering and Inspection Corporation (JAPEIC) has been carried out the project entrusted by the Ministry of International Trade and Industry (MITI). We focus on a correlation between the reduction of absorbed energy and the interaction of the heat affected zone (HAZ) and the plastic zone, to establish applicable reconstitution conditions for Charpy specimens. The relationship between the plastic zone width and the absorbed energy has been obtained by estimating the plastic zone width from the hardness distribution of the Charpy specimens. Impact tests of reconstituted specimens with 10 mm-length insert using the surface activated joining method were performed and the test results were compared to those obtained by the standard specimens. By comparing the length of insert material to the sum of HAZ width and plastic zone width, it is clear that the interaction causes the reduction of the absorbed energy. Hence, the applicable conditions of reconstituted Charpy specimens could be assessed by comparing the insert length to the sum of HAZ width and plastic zone width. Moreover the effects of the possible deviations from the standard shape and size specimens for the reconstituted specimens were studied. (authors)

  3. Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Program. PSF Blind Test workshop minutes. Summary

    International Nuclear Information System (INIS)

    Guthrie, G.L.; Lippincott, E.P.; McGarry, E.D.

    1984-01-01

    A ''Blind Test'' workshop was held on April 9-11, 1984, at the Holiday Inn in Richland, WA. At the workshop, participant groups compared ''Blind'' calculations with existing data which was unavailable to them at the time the calculations were made. The purpose of the exercise was to allow each participant group to test the group's ability to predict ''in-wall'' mechanical property degradation for a simulated nuclear reactor pressure vessel irradiation

  4. Nutritional surveillance.

    Science.gov (United States)

    Mason, J B; Mitchell, J T

    1983-01-01

    The concept of nutritional surveillance is derived from disease surveillance, and means "to watch over nutrition, in order to make decisions that lead to improvements in nutrition in populations". Three distinct objectives have been defined for surveillance systems, primarily in relation to problems of malnutrition in developing countries: to aid long-term planning in health and development; to provide input for programme management and evaluation; and to give timely warning of the need for intervention to prevent critical deteriorations in food consumption. Decisions affecting nutrition are made at various administrative levels, and the uses of different types of nutritional surveillance information can be related to national policies, development programmes, public health and nutrition programmes, and timely warning and intervention programmes. The information should answer specific questions, for example concerning the nutritional status and trends of particular population groups.Defining the uses and users of the information is the first essential step in designing a system; this is illustrated with reference to agricultural and rural development planning, the health sector, and nutrition and social welfare programmes. The most usual data outputs are nutritional outcome indicators (e.g., prevalence of malnutrition among preschool children), disaggregated by descriptive or classifying variables, of which the commonest is simply administrative area. Often, additional "status" indicators, such as quality of housing or water supply, are presented at the same time. On the other hand, timely warning requires earlier indicators of the possibility of nutritional deterioration, and agricultural indicators are often the most appropriate.DATA COME FROM TWO MAIN TYPES OF SOURCE: administrative (e.g., clinics and schools) and household sample surveys. Each source has its own advantages and disadvantages: for example, administrative data often already exist, and can be

  5. Guess who's not coming to dinner? Evaluating online restaurant reservations for disease surveillance.

    Science.gov (United States)

    Nsoesie, Elaine O; Buckeridge, David L; Brownstein, John S

    2014-01-22

    Alternative data sources are used increasingly to augment traditional public health surveillance systems. Examples include over-the-counter medication sales and school absenteeism. We sought to determine if an increase in restaurant table availabilities was associated with an increase in disease incidence, specifically influenza-like illness (ILI). Restaurant table availability was monitored using OpenTable, an online restaurant table reservation site. A daily search was performed for restaurants with available tables for 2 at the hour and at half past the hour for 22 distinct times: between 11:00 am-3:30 pm for lunch and between 6:00-11:30 PM for dinner. In the United States, we examined table availability for restaurants in Boston, Atlanta, Baltimore, and Miami. For Mexico, we studied table availabilities in Cancun, Mexico City, Puebla, Monterrey, and Guadalajara. Time series of restaurant use was compared with Google Flu Trends and ILI at the state and national levels for the United States and Mexico using the cross-correlation function. Differences in restaurant use were observed across sampling times and regions. We also noted similarities in time series trends between data on influenza activity and restaurant use. In some settings, significant correlations greater than 70% were noted between data on restaurant use and ILI trends. This study introduces and demonstrates the potential value of restaurant use data for event surveillance.

  6. Design of quality assurance surveillance of geotechnical investigation in evaluation of nuclear power plants siting

    International Nuclear Information System (INIS)

    Made Pramayuni; Haendra Subekti

    2011-01-01

    System of building Nuclear Power Plants (NPP) is built above ground surface and rocks. Therefore, the geotechnical aspects evaluation of NPP siting in particular must be implemented properly and accurately. The successful of the design and construction of the building system is influenced by geotechnical conditions in the vicinity of NPP will be built. To be able to perform geotechnical analysis is good and true; it's required data of surface/underground completely. These data can be obtained directly not only from the geotechnical field investigations, but also can be obtained from the laboratory tests results. To ensure that geotechnical investigations are conducted effectively and efficiently, produce accurate data, as well as meeting the requirements of safety, health, safety, environmental, quality and economic, then the Quality Assurance Program (QAP) should be established and implemented. Supervision of the QAP implementation is required to ensure the work is done according to QAP that have been established and applicable requirement. (author)

  7. Evaluation of the Danish footpad lesion surveillance in conventional and organic broilers

    DEFF Research Database (Denmark)

    Lund, Vibe Pedersen; Nielsen, Liza Rosenbaum; Oliveira, A.R.S.

    2017-01-01

    to predefined criteria for visual and invasive investigations of the feet derived from the official system, was compared to the official scores assigned at slaughter. Footpad lesions were primarily chronic, representing a wide range of severity. Marked differences in color, shape, and degree of papillary......Danish legislation prescribes surveillance of footpad dermatitis (FPD) at slaughter as an indicator of on-farm broiler welfare. The 3-point scale being used was originally developed in Sweden to score feet from conventional broilers, but the extent and causes of misclassifications have not been...... investigated, neither in conventional nor organic broilers. Hence, we investigated the performance of the official Danish FPD scoring system in conventional and organic broilers by assessing agreement between official scores from the slaughterhouse and consecutive scoring of the same feet by a reference method...

  8. The advanced test reactor strategic evaluation program

    International Nuclear Information System (INIS)

    Buescher, B.J.

    1989-01-01

    Since the Chernobly accident, the safety of test reactors and irradiation facilities has been critically evaluated from the public's point of view. A systematic evaluation of all safety, environmental, and operational issues must be made in an integrated manner to prioritize actions to maximize benefits while minimizing costs. Such a proactive program has been initiated at the Advanced Test Reactor (ATR). This program, called the Strategic Evaluation Program (STEP), is being conducted for the ATR to provide integrated safety and operational reviews of the reactor against the standards applied to licensed commercial power reactors. This has taken into consideration the lessons learned by the US Nuclear Regulatory Commission (NRC) in its Systematic Evaluation Program (SEP) and the follow-on effort known as the Integrated Safety Assessment Program (ISAP). The SEP was initiated by the NRC to review the designs of older operating nuclear power plants to confirm and document their safety. The ATR STEP objectives are discussed

  9. Results of cytogenetic surveillance of rural populations adjoining to Semipalatinsk test site

    International Nuclear Information System (INIS)

    Abdil'dinova, G.Zh.; Kundakbaeva, G.B.; Zhunusova, A.B.

    1997-01-01

    Purpose of the work is study of somatic cytogenetic effects with taking into consideration chromosomal aberration of population from Beskaragaj district of Semipalatinsk region exposed to influence of conducted nuclear tests on Semipalatinsk test site. Cultures of lymphocyates of peripheral flood were studied. Control group made up 15 man living in Akmola region locating out of radiation contaminated zone. It is determined, that common frequency of chromosomal aberration make up 3.6 on 100 cells. At that frequency of pair fragments made up 2.0 on 100 metaphases (0.2 in control group); dicentrics and center rings were revealed with summary frequency 0.6 on 100 metaphases and that is approximately in 15 fold greater than control index - 0.03 on 100 cells. Stable radiation markers (translocations, deletions) revealed with frequency 1.07 on 100 cells (control make up 0.4 on 100 cells). By results of of conducted cytogenetic analysis the attempt of mean group effective equivalent dose reconstruction received with inhabitants of Beskaragaj district is undertaken. It was calculated, that population of researched district have been got dose loading in 9.09 rem

  10. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  11. Evaluation of Nucleic Acid Preservation Cards for West Nile Virus Testing in Dead Birds

    Science.gov (United States)

    Foss, Leslie; Reisen, William K.; Fang, Ying; Kramer, Vicki; Padgett, Kerry

    2016-01-01

    The California West Nile virus (WNV) Dead Bird Surveillance Program (DBSP) is an important component of WNV surveillance in the state. We evaluated FTA™ and RNASound™ cards as an alternative method for sampling dead birds for WNV molecular testing as these cards allow for more cost effective, rapid, and safer diagnostic sampling than the shipment of bird carcasses. To evaluate accuracy of results among avian sampling regimes, Reverse-Transcription Polymerase Chain Reaction (RT-PCR) results from FTA™ and RNASound™ cards were compared with results from kidney tissue, brain tissue, or oral swabs in lysis buffer in 2012–2013. In addition, RT-PCR results were compared with results from oral swabs tested by rapid antigen tests (RAMP™ and VecTOR™). While test results from the cards were not as sensitive as kidney tissue testing, they were more likely to provide accurate results than rapid antigen tests, and detected WNV in corvids as well as in other passerines, raptors, and waterfowl. Overall, WNV RT-PCR cycle threshold (Ct) scores from the cards were higher than those from tissue testing, but both card products displayed high sensitivity and specificity. American Crow samples provided the highest sensitivity. The cards also proved to be easier and more convenient vehicles for collecting and shipping samples, and in 2014 our program launched use of RNASound™ cards in the DBSP. Both FTA™ and RNASound™ products displayed 96% agreement with tissue results and are an adequate alternative sampling method for WNV dead bird testing. PMID:27341492

  12. Evaluation of Nucleic Acid Preservation Cards for West Nile Virus Testing in Dead Birds.

    Directory of Open Access Journals (Sweden)

    Leslie Foss

    Full Text Available The California West Nile virus (WNV Dead Bird Surveillance Program (DBSP is an important component of WNV surveillance in the state. We evaluated FTA™ and RNASound™ cards as an alternative method for sampling dead birds for WNV molecular testing as these cards allow for more cost effective, rapid, and safer diagnostic sampling than the shipment of bird carcasses. To evaluate accuracy of results among avian sampling regimes, Reverse-Transcription Polymerase Chain Reaction (RT-PCR results from FTA™ and RNASound™ cards were compared with results from kidney tissue, brain tissue, or oral swabs in lysis buffer in 2012-2013. In addition, RT-PCR results were compared with results from oral swabs tested by rapid antigen tests (RAMP™ and VecTOR™. While test results from the cards were not as sensitive as kidney tissue testing, they were more likely to provide accurate results than rapid antigen tests, and detected WNV in corvids as well as in other passerines, raptors, and waterfowl. Overall, WNV RT-PCR cycle threshold (Ct scores from the cards were higher than those from tissue testing, but both card products displayed high sensitivity and specificity. American Crow samples provided the highest sensitivity. The cards also proved to be easier and more convenient vehicles for collecting and shipping samples, and in 2014 our program launched use of RNASound™ cards in the DBSP. Both FTA™ and RNASound™ products displayed 96% agreement with tissue results and are an adequate alternative sampling method for WNV dead bird testing.

  13. The particle swarm optimization algorithm applied to nuclear systems surveillance test planning

    International Nuclear Information System (INIS)

    Siqueira, Newton Norat

    2006-12-01

    This work shows a new approach to solve availability maximization problems in electromechanical systems, under periodic preventive scheduled tests. This approach uses a new Optimization tool called PSO developed by Kennedy and Eberhart (2001), Particle Swarm Optimization, integrated with probabilistic safety analysis model. Two maintenance optimization problems are solved by the proposed technique, the first one is a hypothetical electromechanical configuration and the second one is a real case from a nuclear power plant (Emergency Diesel Generators). For both problem PSO is compared to a genetic algorithm (GA). In the experiments made, PSO was able to obtain results comparable or even slightly better than those obtained b GA. Therefore, the PSO algorithm is simpler and its convergence is faster, indicating that PSO is a good alternative for solving such kind of problems. (author)

  14. Reactivity anomaly surveillance in the Fast Flux Test Facility through cycle 3

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.

    1984-08-01

    The technique for monitoring core reactivity during power operation used at the Fast Flux Test Facility (FFTF) is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. It is implemented on the Plant Data System (PDS) computer and thus provides rapid indication of any abnormal core conditions. The prediction algorithms use thermal-hydraulic, control rod position and neutron flux sensor information to predict the core reactivity state. Initial results of using this technique based mainly on theoretical formulations is presented. The results show that the reactivity changes due to increasing reactor power (power defect) and burnup of the fuel were within approx. 16% of predicted values. To increase the sensitivity and accuracy of this technique, the prediction algorithms were calibrated to actual operating data. The work of calibrating this technique and the results of using the calibrated technique up through the third full operating cycle are summarized

  15. Evaluation 2000 and regulation and method. Release monitoring and environmental surveillance around Cea centers; Bilan 2000 et reglementation et methode. Controle des rejets et surveillance de l'environnement des centres CEA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-06-01

    This publication counts for the year 2000 for the evaluation of liquid and gaseous radioactive effluents releases and the radioactivity levels measured in the vicinity of Cea centers, through the air, water, vegetation and milk surveillance. An analysis of the results from 1996 to 2000 allows to follow their evolution. A second booklet develops the sampling and measurement methods made on effluents in environment. It present besides the regulation applied to effluents monitoring. (N.C.)

  16. A Simulation-Based Evaluation of Premovement Active Surveillance Protocol Options for the Managed Movement of Turkeys to Slaughter During an Outbreak of Highly Pathogenic Avian Influenza in the United States.

    Science.gov (United States)

    Todd Weaver, J; Malladi, Sasidhar; Bonney, Peter J; Patyk, Kelly A; Bergeron, Justin G; Middleton, Jamie L; Alexander, Catherine Y; Goldsmith, Timothy J; Halvorson, David A

    2016-05-01

    Risk management decisions associated with live poultry movement during a highly pathogenic avian influenza (HPAI) outbreak should be carefully considered. Live turkey movements may pose a risk for disease spread. On the other hand, interruptions in scheduled movements can disrupt business continuity. The Secure Turkey Supply (STS) Plan was developed through an industry-government-academic collaboration to address business continuity concerns that might arise during a HPAI outbreak. STS stakeholders proposed outbreak response measure options that were evaluated through risk assessment. The developed approach relies on 1) diagnostic testing of two pooled samples of swabs taken from dead turkeys immediately before movement via the influenza A matrix gene real-time reverse transcriptase polymerase chain reaction (rRT-PCR) test; 2) enhanced biosecurity measures in combination with a premovement isolation period (PMIP), restricting movement onto the premises for a few days before movement to slaughter; and 3) incorporation of a distance factor from known infected flocks such that exposure via local area spread is unlikely. Daily exposure likelihood estimates from spatial kernels from past HPAI outbreaks were coupled with simulation models of disease spread and active surveillance to evaluate active surveillance protocol options that differ with respect to the number of swabs per pooled sample and the timing of the tests in relation to movement. Simulation model results indicate that active surveillance testing, in combination with strict biosecurity, substantially increased HPAI virus detection probability. When distance from a known infected flock was considered, the overall combined likelihood of moving an infected, undetected turkey flock to slaughter was predicted to be lower at 3 and 5 km. The analysis of different active surveillance protocol options is designed to incorporate flexibility into HPAI emergency response plans.

  17. CMOS test and evaluation a physical perspective

    CERN Document Server

    Bhushan, Manjul

    2015-01-01

    This book extends test structure applications described in Microelectronic Test Struc­tures for CMOS Technology (Springer 2011) to digital CMOS product chips. Intended for engineering students and professionals, this book provides a single comprehensive source for evaluating CMOS technology and product test data from a basic knowledge of the physical behavior of the constituent components. Elementary circuits that exhibit key properties of complex CMOS chips are simulated and analyzed, and an integrated view of design, test and characterization is developed. Appropriately designed circuit monitors embedded in the CMOS chip serve to correlate CMOS technology models and circuit design tools to the hardware and also aid in test debug. Impact of silicon process variability, reliability, and power and performance sensitivities to a range of product application conditions are described. Circuit simulations exemplify the methodologies presented, and problems are included at the end of the chapters.

  18. Introduction to surveillance studies

    CERN Document Server

    Petersen, JK

    2012-01-01

    Introduction & OverviewIntroduction Brief History of Surveillance Technologies & TechniquesOptical SurveillanceAerial Surveillance Audio Surveillance Radio-Wave SurveillanceGlobal Positioning Systems Sensors Computers & the Internet Data Cards Biochemical Surveillance Animal Surveillance Biometrics Genetics Practical ConsiderationsPrevalence of Surveillance Effectiveness of Surveillance Freedom & Privacy IssuesConstitutional Freedoms Privacy Safeguards & Intrusions ResourcesReferences Glossary Index

  19. User evaluation of a GUI for controlling an autonomous persistent surveillance team

    Science.gov (United States)

    Scerri, Paul; Owens, Sean; Sycara, Katia; Lewis, Michael

    2010-04-01

    In future military missions, there will be many sensor assets collecting much important information about the environment. User control over surveillance assets is important to ensure that the specific data collected is appropriate for the current mission. Unfortunately, previous work has shown that individual users cannot effectively control more than about four assets, even if the assets have significant autonomy. In the ACCAST project, we hypothesized that by including autonomous teamwork between the assets and allowing users to interact by describing what the team as a whole and specific sub-teams should do, we could dramatically scale up the number of assets an individual user could effectively control. In this paper, we present the results of an experiment where users controlled up to 30 autonomous assets performing a complex mission. The assets autonomously worked together using sophisticated teamwork and the user could tell sub-teams to execute team oriented plans which described the steps required to achieve a team objective without describing exactly which asset performed which role and without having to specify how the team should handle routine information sharing, communications and failure circumstances. The users, soldiers from Fort Benning, were surprisingly good at managing the assets and were all able to complete the complex mission with extremely low friendly and civilian casualties.

  20. A new paradigm for Aedes spp. surveillance using gravid ovipositing sticky trap and NS1 antigen test kit.

    Science.gov (United States)

    Lau, Sai Ming; Chua, Tock H; Sulaiman, Wan-Yussof; Joanne, Sylvia; Lim, Yvonne Ai-Lian; Sekaran, Shamala Devi; Chinna, Karuthan; Venugopalan, Balan; Vythilingam, Indra

    2017-03-21

    Dengue remains a serious public health problem in Southeast Asia and has increased 37-fold in Malaysia compared to decades ago. New strategies are urgently needed for early detection and control of dengue epidemics. We conducted a two year study in a high human density dengue-endemic urban area in Selangor, where Gravid Ovipositing Sticky (GOS) traps were set up to capture adult Aedes spp. mosquitoes. All Aedes mosquitoes were tested using the NS1 dengue antigen test kit. All dengue cases from the study site notified to the State Health Department were recorded. Weekly microclimatic temperature, relative humidity (RH) and rainfall were monitored. Aedes aegypti was the predominant mosquito (95.6%) caught in GOS traps and 23% (43/187 pools of 5 mosquitoes each) were found to be positive for dengue using the NS1 antigen kit. Confirmed cases of dengue were observed with a lag of one week after positive Ae. aegypti were detected. Aedes aegypti density as analysed by distributed lag non-linear models, will increase lag of 2-3 weeks for temperature increase from 28 to 30 °C; and lag of three weeks for increased rainfall. Proactive strategy is needed for dengue vector surveillance programme. One method would be to use the GOS trap which is simple to setup, cost effective (below USD 1 per trap) and environmental friendly (i.e. use recyclable plastic materials) to capture Ae. aegypti followed by a rapid method of detecting of dengue virus using the NS1 dengue antigen kit. Control measures should be initiated when positive mosquitoes are detected.

  1. Surveillance Culture

    DEFF Research Database (Denmark)

    2017-01-01

    What does it mean to live in a world full of surveillance? In this documentary film, we take a look at everyday life in Denmark and how surveillance technologies and practices influence our norms and social behaviour. Researched and directed by Btihaj Ajana and Anders Albrechtslund....

  2. Newly developed non-destructive testing method for evaluation of irradiation brittleness of structural materials using ultrasonic

    International Nuclear Information System (INIS)

    Ishii, Toshimitsu; Ooka, Norikazu; Kato, Yoshiaki; Saito, Junichi; Hoshiya, Taiji; Shibata, Saburo; Kobayashi, Hideo

    1999-01-01

    Surveillance testing is important to evaluate neutron irradiation embrittlement of reactor pressure vessel material for long life operation. An alternative test method for evaluating the irradiation embrittlement of the pressure vessel material will have to be proposed to support the limited number of surveillance test specimens in order to manage the plant life to be extended. In this study, ultrasonic testing for irradiated A533B-1 steel and weld metal was applied to examine material degradation nondestructively. With increasing the shift of Charpy 41 J transition temperature, ultrasonic velocity decreased and attenuation coefficient of ultrasonic wave increased. Especially, the difference of ultrasonic velocity for 5 MHz shear wave between as-received and irradiated material is corresponding to the shift of transition temperature showing material degradation. (author)

  3. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Science.gov (United States)

    Binks, Michael J; Temple, Beth; Kirkham, Lea-Ann; Wiertsema, Selma P; Dunne, Eileen M; Richmond, Peter C; Marsh, Robyn L; Leach, Amanda J; Smith-Vaughan, Heidi C

    2012-01-01

    Unambiguous identification of nontypeable Haemophilus influenzae (NTHi) is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh); however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22), Hh (n = 27) or equivocal (n = 11), were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3) and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  4. Physicians' subjectivity in evaluating oxytocin challenge tests.

    Science.gov (United States)

    Peck, T M

    1980-07-01

    Five physicians subspecializing in maternal-fetal medicine individually evaluated 50 oxytocin challenge tests (OCTs), of which 33 were originally read as positive. There was considerable disagreement among the study physicians (SPs) such that 2 SPs would agree, on the average, only 52% of the time on any one OCT. The SPs were also asked to evaluate fetal heart rate (FHR) reactivity patterns, if present. Again, there was great disagreement. When the majority (3 of 5 or more) of SPs agreed on the OCT result and/or reactivity, there was reasonable correlation with neonatal outcome, indicating the validity of the physiologic premise of the test. In particular, the presence or absence of FHR accelerations with fetal motion, regardless of the OCT reading, correlated extremely well with eventual neonatal outcome. This indicates that the most significant variable in antepartum FHR monitoring is the FHR acceleration pattern.

  5. Evaluating Google, Twitter, and Wikipedia as Tools for Influenza Surveillance Using Bayesian Change Point Analysis: A Comparative Analysis.

    Science.gov (United States)

    Sharpe, J Danielle; Hopkins, Richard S; Cook, Robert L; Striley, Catherine W

    2016-10-20

    Traditional influenza surveillance relies on influenza-like illness (ILI) syndrome that is reported by health care providers. It primarily captures individuals who seek medical care and misses those who do not. Recently, Web-based data sources have been studied for application to public health surveillance, as there is a growing number of people who search, post, and tweet about their illnesses before seeking medical care. Existing research has shown some promise of using data from Google, Twitter, and Wikipedia to complement traditional surveillance for ILI. However, past studies have evaluated these Web-based sources individually or dually without comparing all 3 of them, and it would be beneficial to know which of the Web-based sources performs best in order to be considered to complement traditional methods. The objective of this study is to comparatively analyze Google, Twitter, and Wikipedia by examining which best corresponds with Centers for Disease Control and Prevention (CDC) ILI data. It was hypothesized that Wikipedia will best correspond with CDC ILI data as previous research found it to be least influenced by high media coverage in comparison with Google and Twitter. Publicly available, deidentified data were collected from the CDC, Google Flu Trends, HealthTweets, and Wikipedia for the 2012-2015 influenza seasons. Bayesian change point analysis was used to detect seasonal changes, or change points, in each of the data sources. Change points in Google, Twitter, and Wikipedia that occurred during the exact week, 1 preceding week, or 1 week after the CDC's change points were compared with the CDC data as the gold standard. All analyses were conducted using the R package "bcp" version 4.0.0 in RStudio version 0.99.484 (RStudio Inc). In addition, sensitivity and positive predictive values (PPV) were calculated for Google, Twitter, and Wikipedia. During the 2012-2015 influenza seasons, a high sensitivity of 92% was found for Google, whereas the PPV for

  6. The Advanced Test Reactor Strategic Evaluation Program

    International Nuclear Information System (INIS)

    Buescher, B.J.

    1990-01-01

    A systematic evaluation of safety, environmental, and operational issues has been initiated at the Advanced Test Reactor (ATR). This program, the Strategic Evaluation Program (STEP), provides an integrated review of safety and operational issues against the standards applied to licensed commercial facilities. In the review of safety issues, 18 deviations were identified which required prompt attention. Resolution of these items has been accelerated in the program. An integrated living schedule is being developed to address the remaining findings. A risk evaluation is being performed on the proposed corrective actions and these actions will then be formally ranked in order of priority based on considerations of safety and operational significance. Once the final ranking is completed, an integrated schedule will be developed, which will include considerations of availability of funding and operating schedule. 3 refs., 2 figs

  7. Central line-associated bloodstream infections in adult hematology patients with febrile neutropenia: an evaluation of surveillance definitions using differential time to blood culture positivity.

    Science.gov (United States)

    Freeman, Joshua T; Elinder-Camburn, Anna; McClymont, Catherine; Anderson, Deverick J; Bilkey, Mary; Williamson, Deborah A; Berkahn, Leanne; Roberts, Sally A

    2013-01-01

    We used differential time to positivity between central and peripheral blood cultures to evaluate the positive predictive value (PPV) of the National Healthcare Safety Network central line-associated bloodstream infection (CLABSI) surveillance definition among hematology patients with febrile neutropenia. The PPV was 27.7%, which suggests that, when the definition is applied to this population, CLABSI rates will be substantially overestimated.

  8. Evaluation of Efficacy and Sedative Profiles of H1 Antihistamines by Large-Scale Surveillance Using the Visual Analogue Scale (VAS

    Directory of Open Access Journals (Sweden)

    Norimasa Izumi

    2008-01-01

    Conclusions: The sedative properties of the H1 antihistamines obtained from VAS analysis were very similar to those of H1R occupancy from positron emission tomography (PET studies and PIR from meta-analysis. Our results indicate that large-scale surveillance using VAS might be useful to evaluate the profiles of H1 antihistamines.

  9. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Directory of Open Access Journals (Sweden)

    Michael J Binks

    Full Text Available BACKGROUND: Unambiguous identification of nontypeable Haemophilus influenzae (NTHi is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh; however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. METHODOLOGY/PRINCIPAL FINDINGS: Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22, Hh (n = 27 or equivocal (n = 11, were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3 and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. CONCLUSIONS/SIGNIFICANCE: Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  10. Discrete Address Beacon System (DABS) Baseline Test and Evaluation.

    Science.gov (United States)

    1980-04-01

    maturing of the DABS/Automatic Traffic Advisory and Resolution Service ( ATARS ) system concept, would require further study and test prior to issuance of...surveillance, Automatic Traffic Advisory and Resolution Service ( ATARS ) and communications capabilities required for air traffic control (ATC) in the...1980’s and 1990’s. Compatibility with ATCRBS has been emphasized to permit an extended and economical transition. The requirement for the development

  11. Evaluation methodologies for security testing biometric systems beyond technological evaluation

    OpenAIRE

    Fernández Saavedra, María Belén

    2013-01-01

    The main objective of this PhD Thesis is the specification of formal evaluation methodologies for testing the security level achieved by biometric systems when these are working under specific contour conditions. This analysis is conducted through the calculation of the basic technical biometric system performance and its possible variations. To that end, the next two relevant contributions have been developed. The first contribution is the definition of two independent biometric performance ...

  12. The Copyright Surveillance Industry

    Directory of Open Access Journals (Sweden)

    Mike Zajko

    2015-09-01

    Full Text Available Creative works are now increasingly distributed as digital “content” through the internet, and copyright law has created powerful incentives to monitor and control these flows. This paper analyzes the surveillance industry that has emerged as a result. Copyright surveillance systems identify copyright infringement online and identify persons to hold responsible for infringing acts. These practices have raised fundamental questions about the nature of identification and attribution on the internet, as well as the increasing use of algorithms to make legal distinctions. New technologies have threatened the profits of some media industries through copyright infringement, but also enabled profitable forms of mass copyright surveillance and enforcement. Rather than a system of perfect control, copyright enforcement continues to be selective and uneven, but its broad reach results in systemic harm and provides opportunities for exploitation. It is only by scrutinizing copyright surveillance practices and copyright enforcement measures that we can evaluate these consequences.

  13. Audit of Helicobacter pylori Testing in Microbiology Laboratories in England: To Inform Compliance with NICE Guidance and the Feasibility of Routine Antimicrobial Resistance Surveillance

    Directory of Open Access Journals (Sweden)

    Rosalie Allison

    2016-01-01

    Full Text Available Introduction. The National Institute for Health and Clinical Excellence (NICE guidance recommends that dyspeptic patients are tested for Helicobacter pylori using a urea breath test, stool antigen test, or serology. Antibiotic resistance in H. pylori is globally increasing, but treatment in England is rarely guided by susceptibility testing or surveillance. Aims. To determine compliance of microbiology laboratories in England with NICE guidance and whether laboratories perform culture and antibiotic susceptibility testing (AST. Methods. In 2015, 170 accredited English microbiology laboratories were surveyed, by email. Results. 121/170 (71% laboratories responded; 96% provided H. pylori testing (78% on site. 94% provided H. pylori diagnosis using stool antigen; only four provided serology as their noninvasive test; 3/4 of these encouraged urea breath tests in their acute trusts. Only 22/94 (23% of the laboratories performed H. pylori cultures from gastric biopsies on site; 9/22 performed AST, but the vast majority processed less than one specimen/week. Conclusions. Only five laboratories in England do not comply with NICE guidance; these will need the guidance reinforced. National surveillance needs to be implemented; culture-based AST would need to be centralised. Moving forward, detection of resistance in H. pylori from stool specimens using molecular methods (PCR needs to be explored.

  14. AFFTC Instruction 99-1, Test and Evaluation Test Plans

    National Research Council Canada - National Science Library

    Crane, Roger

    2002-01-01

    .... Test Information Sheets (TISs) are actually appendices to test plans and contain sufficient information for use by a flight test engineer to develop flight test cards and for management to discern the overall technical approach being taken...

  15. Test, measurement and evaluation with the mine boot test and evaluation system

    CSIR Research Space (South Africa)

    Ramaloko, PM

    2014-09-01

    Full Text Available Protective footwear that mitigates the shock transferred to the victim’s leg during an antipersonnel landmine blast need to be evaluated to verify their protection levels. The Mine Boot Test and Evaluation System which include a surrogate lower leg...

  16. Surveillance Pleasures

    DEFF Research Database (Denmark)

    Albrechtslund, Anders

    The notorious intensification and digitalization of surveillance technologies and practices in today’s society has brought about numerous changes. These changes have been widely noticed, described and discussed across many academic disciplines. However, the contexts of entertainment, play...

  17. Evaluation of Mycology Laboratory Proficiency Testing

    Science.gov (United States)

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  18. Thermionic system evaluated test (TSET) facility description

    Science.gov (United States)

    Fairchild, Jerry F.; Koonmen, James P.; Thome, Frank V.

    1992-01-01

    A consortium of US agencies are involved in the Thermionic System Evaluation Test (TSET) which is being supported by the Strategic Defense Initiative Organization (SDIO). The project is a ground test of an unfueled Soviet TOPAZ-II in-core thermionic space reactor powered by electrical heat. It is part of the United States' national thermionic space nuclear power program. It will be tested in Albuquerque, New Mexico at the New Mexico Engineering Research Institute complex by the Phillips Laboratoty, Sandia National Laboratories, Los Alamos National Laboratory, and the University of New Mexico. One of TSET's many objectives is to demonstrate that the US can operate and test a complete space nuclear power system, in the electrical heater configuration, at a low cost. Great efforts have been made to help reduce facility costs during the first phase of this project. These costs include structural, mechanical, and electrical modifications to the existing facility as well as the installation of additional emergency systems to mitigate the effects of utility power losses and alkali metal fires.

  19. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico

    International Nuclear Information System (INIS)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M.

    2011-11-01

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm 3 in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  20. Family Planning Evaluation. Abortion Surveillance Report--Legal Abortions, United States, Annual Summary, 1970.

    Science.gov (United States)

    Center for Disease Control (DHEW/PHS), Atlanta, GA.

    This report summarizes abortion information received by the Center for Disease Control from collaborators in state health departments, hospitals, and other pertinent sources. While it is intended primarily for use by the above sources, it may also interest those responsible for family planning evaluation and hospital abortion planning. Information…

  1. Nutrition and Health with an Evaluation on Nutritional Surveillance in the United States.

    Science.gov (United States)

    Congress of the U.S., Washington, DC. Senate Select Committee on Nutrition and Human Needs.

    Focusing on America's self-knowledge about its nutritional health, this report deals with the availability of nutrition evaluation and counseling to individuals and the adequacy of the national nutrition monitoring system. Bureaucratic and political problems of applying nutritional health considerations to food policy are also examined. Nutrition…

  2. Antimicrobial susceptibility trends among gram-positive and -negative clinical isolates collected between 2005 and 2012 in Mexico: results from the Tigecycline Evaluation and Surveillance Trial.

    Science.gov (United States)

    Morfin-Otero, Rayo; Noriega, Eduardo Rodriguez; Dowzicky, Michael J

    2015-12-15

    The Tigecycline Evaluation and Surveillance Trial (T.E.S.T) is a global antimicrobial surveillance study of both gram-positive and gram-negative organisms. This report presents data on antimicrobial susceptibility among organisms collected in Mexico between 2005 and 2012 as part of T.E.S.T., and compares rates between 2005-2007 and 2008-2012. Each center in Mexico submitted at least 200 isolates per collection year; including 65 gram-positive isolates and 135 gram-negative isolates. Minimum inhibitory concentrations (MICs) were determined using Clinical Laboratory Standards Institute (CLSI) broth microdilution methodology and antimicrobial susceptibility was established using the 2013 CLSI-approved breakpoints. For tigecycline US Food and Drug Administration (FDA) breakpoints were applied. Isolates of E. coli and K. pneumoniae with a MIC for ceftriaxone of >1 mg/L were screened for ESBL production using the phenotypic confirmatory disk test according to CLSI guidelines. The rates of some key resistant phenotypes changed during this study: vancomycin resistance among Enterococcus faecium decreased from 28.6 % in 2005-2007 to 19.1 % in 2008-2012, while β-lactamase production among Haemophilus influenzae decreased from 37.6 to 18.9 %. Conversely, methicillin-resistant Staphylococcus aureus increased from 38.1 to 47.9 %, meropenem-resistant Acinetobacter spp. increased from 17.7 to 33.0 % and multidrug-resistant Acinetobacter spp. increased from 25.6 to 49.7 %. The prevalence of other resistant pathogens was stable over the study period, including extended-spectrum β-lactamase-positive Escherichia coli (39.0 %) and Klebsiella pneumoniae (25.0 %). The activity of tigecycline was maintained across the study years with MIC90s of ≤2 mg/L against Enterococcus spp., S. aureus, Streptococcus agalactiae, Streptococcus pneumoniae, Enterobacter spp., E. coli, K. pneumoniae, Klebsiella oxytoca, Serratia marcescens, H. influenzae, and Acinetobacter spp. All gram

  3. Country-wide surveillance of molecular markers of antimalarial drug resistance in Senegal by use of positive Malaria Rapid Diagnostic Tests

    DEFF Research Database (Denmark)

    Ndiaye, Magatte; Sow, Doudou; Nag, Sidsel

    2017-01-01

    of drug resistance. Therefore, surveillance of drug resistance in the malaria parasites is essential. The objective of this pilot study was to test the feasibility of routinely sampled malaria rapid diagnostic tests (RDTs) at a national scale to assess the temporal changes in the molecular profiles...... of antimalarial drug resistance markers of Plasmodium falciparum parasites. Overall, 9,549 positive malaria RDTs were collected from 14 health facilities across the country. A limited random set of RDTs were analyzed regarding Pfcrt gene polymorphisms at codon 72-76. Overall, a high but varied prevalence (> 50...

  4. Evaluation of the adverse events following immunizations surveillance system in Harare City, Zimbabwe, 2016: a descriptive cross sectional study.

    Science.gov (United States)

    Zvanaka, Sithole; Tsitsi, Juru; Chonzi, Prosper; Shambira, Gerald; Gombe, Notion Tafara; Tshimanga, Mufuta

    2017-01-01

    Vaccines safety are monitored by looking for Adverse Events Following Immunizations (AEFIs). A review of the 2014 Harare City consolidated monthly return form (T5) revealed that 28 AEFIs were seen in 2014. However, only 21 were reported through the system. We therefore evaluated the Harare City AEFI surveillance system to assess its usefulness. A descriptive cross sectional study was conducted. Twenty one of 41 clinics were randomly selected and 51 health workers were randomly recruited. Interviewer administered questionnaires were used to collect data. Epi info 7 was used to generate frequencies, means and proportions. Out of 51 respondents, 50 (98%) knew the purpose of AEFI system, 48 (94%) knew at least two presenting symptoms of AEFIs and 39 (77%) knew the correct date of form submission to the next level. Receiving no feedback 24 (47.1%), fear of victimisation 16 (31.4%) and work overload 11 (21.6%) were the major reasons for under reporting. Eighty six percent perceived the system to be simple and 43 (84%) were willing to continue participating. Fifty three percent (27) reported taking public health actions (such as awareness campaigns & making follow ups) basing on AEFI data collected. All 46 reviewed forms were completely filled and submitted in time. All 21 clinics had written AEFI guidelines and case definitions. Only 14 of 21 clinics had adequately stocked emergency drugs. The total cost for a single notification was estimated at US$22.30. The system was useful, simple, acceptable, timely, stable, representative but costly. The good performance of the system reported in this evaluation could be attributed to high health worker knowledge. Following this evaluation, replenishment of out of stock drugs and follow up of missing 2014 AEFI feedback from MCAZ were done. In addition, making the system electronic is recommended.

  5. Evaluation of the Health Protection Event-Based Surveillance for the London 2012 Olympic and Paralympic Games.

    Science.gov (United States)

    Severi, E; Kitching, A; Crook, P

    2014-06-19

    The Health Protection Agency (HPA) (currently Public Health England) implemented the Health Protection Event-Based Surveillance (EBS) to provide additional national epidemic intelligence for the 2012 London Olympic and Paralympic Games (the Games). We describe EBS and evaluate the system attributes. EBS aimed at identifying, assessing and reporting to the HPA Olympic Coordination Centre (OCC) possible national infectious disease threats that may significantly impact the Games. EBS reported events in England from 2 July to 12 September 2012. EBS sourced events from reports from local health protection units and from screening an electronic application 'HPZone Dashboard' (DB). During this period, 147 new events were reported to EBS, mostly food-borne and vaccine-preventable diseases: 79 from regional units, 144 from DB (76 from both). EBS reported 61 events to the OCC: 21 of these were reported onwards. EBS sensitivity was 95.2%; positive predictive value was 32.8%; reports were timely (median one day; 10th percentile: 0 days - same day; 90th percentile: 3.6 days); completeness was 99.7%; stability was 100%; EBS simplicity was assessed as good; the daily time per regional or national unit dedicated to EBS was approximately 4 hours (weekdays) and 3 hours (weekends). OCC directors judged EBS as efficient, fast and responsive. EBS provided reliable, reassuring, timely, simple and stable national epidemic intelligence for the Games.

  6. Evaluation of a pilot police-led suicide early alert surveillance strategy in the UK.

    Science.gov (United States)

    McGeechan, Grant James; Richardson, Catherine; Weir, Kevin; Wilson, Lynn; O'Neill, Gillian; Newbury-Birch, Dorothy

    2017-07-19

    Those bereaved by suicide are at increased risk of psychological harm, which can be reduced with the provision of timely support. This paper outlines an evaluation of a pilot police-led suicide strategy, in comparison to a coroner-led suicide strategy looking at the number, and length of time it takes for deaths to be recorded for each strategy. Additionally, the police-led strategy offers timely contact from support services for bereaved individuals. We examined what impact this offer of support had on the capacity of support services. A mixed methods evaluation compared how long it took for suspected suicides to be recorded using both strategies. The number of referrals received by support services during the pilot strategy were compared with those from previous years. A feedback focus group, and interviews, were held with key stakeholders. The coroner strategy was more consistent at identifying suspected suicides; however, reports were filed quicker by the police. Bereaved individuals were willing to share contact details with police officers and consent for referral to support services which lead to increased referrals. The focus group and interviews revealed that the pilot police strategy needs better integration into routine police practice. This strategy has the potential to deliver a real benefit to those bereaved by suicide; however, there are still aspects which could be improved. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Characteristics of patients patch tested in the European Surveillance System on Contact Allergies (ESSCA) network, 2009-2012

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Gefeller, Olaf; Giménez-Arnau, Ana

    2015-01-01

    from 63 530 consultations collected by 53 departments from 12 countries participating in the European Surveillance System on Contact Allergies (ESSCA) ( www.essca-dc.org) between 2009 and 2012. RESULTS: Considerable variation in the prevalence of the MOAHLFA factors between departments was found...... one department per country give valuable insights into the spectrum of contact allergy prevalence rates in that country, but are not as representative as national data pooled from several departments....

  8. African swine fever in Uganda: qualitative evaluation of three surveillance methods with implications for other resource-poor settings

    OpenAIRE

    Chenais, Erika; Sternberg Lewerin, Susanna; Boqvist, Sofia; Emanuelson, Ulf; Aliro, Tonny; Tejler, Emma; Cocca, Giampaolo; Masembe, Charles; Ståhl, Karl

    2015-01-01

    Animal diseases impact negatively on households and on national economies. In low-income countries, this pertains especially to socio-economic effects on household level. To control animal diseases and mitigate their impact, it is necessary to understand the epidemiology of the disease in its local context. Such understanding, gained through disease surveillance, is often lacking in resource-poor settings. Alternative surveillance methods have been developed to overcome some of the hurdles ob...

  9. African swine fever in Uganda: qualitative evaluation of three surveillance methods with implications for other resource-poor settings

    OpenAIRE

    Erika eChenais; Erika eChenais; Susanna eSternberg-Lewerin; Sofia eBoqvist; Ulf eEmanuelson; Tonny eAliro; Emma eTejler; Giampaolo eCocca; Charles eMasembe; Karl eStåhl; Karl eStåhl

    2015-01-01

    Animal diseases impact negatively on households and on national economies. In low-income countries this pertains especially to socio-economic effects on household level. To control animal diseases and mitigate their impact, it is necessary to understand the epidemiology of the disease in its local context. Such understanding, gained through disease surveillance, is often lacking in resource-poor settings. Alternative surveillance methods have been developed to overcome some of the hurdles obs...

  10. Antimicrobial susceptibility of quinupristin/dalfopristin tested against gram-positive cocci from Latin America: results from the Global SMART (GSMART surveillance study

    Directory of Open Access Journals (Sweden)

    Sader Helio S.

    2001-01-01

    Full Text Available Gram-positive cocci are important causes of both nosocomial and community-acquired infections, and antimicrobial resistance among these pathogens has become an important problem worldwide. Since resistance among these organisms can vary substantially by geographic location, we conducted a multicenter surveillance study with isolates from five Latin American countries (15 medical centers. Quinupristin/dalfopristin (formerly RP-59500 is a novel streptogramin combination with focused activity against Gram-positive cocci, many exhibiting emerging resistance. The in vitro activity of quinupristin/dalfopristin and 12 other antimicrobial agents were evaluated against 1,948 strains including Staphylococcus aureus (747 strains, coagulase-negative staphylococci (CoNS; 446 strains, enterococci (429 strains, and various Streptococcus spp. (326 strains. Oxacillin resistance was observed in 41% of S. aureus (MIC, or = 13 mm and 40% of CoNS (MIC, or = 18 mm. Vancomycin, teicoplanin, and quinupristin/dalfopristin (MIC90, 0.25 - 1 mug/ml remained effective against all strains, but cross-resistance was high among other tested drugs. The quinupristin/dalfopristin MIC50 for Streptococcus pneumoniae and other streptococci was only 0.5 mug/ml (13% to 28% were penicillin-resistant; 12% to 22% were macrolide-resistant. Enterococci demonstrated variable inhibition by quinupristin/dalfopristin depending upon identification and the susceptibility testing method used. The demonstrated quinupristin/dalfopristin activity against Enterococcus faecium was confirmed, but potential species identification errors with various commercial systems continue to confuse susceptibility statistics, even though some strains of E. faecium confirmed by PCR-based or other molecular identification techniques did have quinupristin/dalfopristin MICs of > or = 4 mug/mL. Most important, glycopeptide-resistant enterococci are rapidly emerging in Latin America, and quinupristin/dalfopristin appears

  11. Evaluation of a Broad-Spectrum Partially Automated Adverse Event Surveillance System: A Potential Tool for Patient Safety Improvement in Hospitals With Limited Resources.

    Science.gov (United States)

    Saikali, Melody; Tanios, Alain; Saab, Antoine

    2017-11-21

    The aim of the study was to evaluate the sensitivity and resource efficiency of a partially automated adverse event (AE) surveillance system for routine patient safety efforts in hospitals with limited resources. Twenty-eight automated triggers from the hospital information system's clinical and administrative databases identified cases that were then filtered by exclusion criteria per trigger and then reviewed by an interdisciplinary team. The system, developed and implemented using in-house resources, was applied for 45 days of surveillance, for all hospital inpatient admissions (N = 1107). Each trigger was evaluated for its positive predictive value (PPV). Furthermore, the sensitivity of the surveillance system (overall and by AE category) was estimated relative to incidence ranges in the literature. The surveillance system identified a total of 123 AEs among 283 reviewed medical records, yielding an overall PPV of 52%. The tool showed variable levels of sensitivity across and within AE categories when compared with the literature, with a relatively low overall sensitivity estimated between 21% and 44%. Adverse events were detected in 23 of the 36 AE categories defined by an established harm classification system. Furthermore, none of the detected AEs were voluntarily reported. The surveillance system showed variable sensitivity levels across a broad range of AE categories with an acceptable PPV, overcoming certain limitations associated with other harm detection methods. The number of cases captured was substantial, and none had been previously detected or voluntarily reported. For hospitals with limited resources, this methodology provides valuable safety information from which interventions for quality improvement can be formulated.

  12. Processing multilevel secure test and evaluation information

    Science.gov (United States)

    Hurlburt, George; Hildreth, Bradley; Acevedo, Teresa

    1994-07-01

    The Test and Evaluation Community Network (TECNET) is building a Multilevel Secure (MLS) system. This system features simultaneous access to classified and unclassified information and easy access through widely available communications channels. It provides the necessary separation of classification levels, assured through the use of trusted system design techniques, security assessments and evaluations. This system enables cleared T&E users to view and manipulate classified and unclassified information resources either using a single terminal interface or multiple windows in a graphical user interface. TECNET is in direct partnership with the National Security Agency (NSA) to develop and field the MLS TECNET capability in the near term. The centerpiece of this partnership is a state-of-the-art Concurrent Systems Security Engineering (CSSE) process. In developing the MLS TECNET capability, TECNET and NSA are providing members, with various expertise and diverse backgrounds, to participate in the CSSE process. The CSSE process is founded on the concepts of both Systems Engineering and Concurrent Engineering. Systems Engineering is an interdisciplinary approach to evolve and verify an integrated and life cycle balanced set of system product and process solutions that satisfy customer needs (ASD/ENS-MIL STD 499B 1992). Concurrent Engineering is design and development using the simultaneous, applied talents of a diverse group of people with the appropriate skills. Harnessing diverse talents to support CSSE requires active participation by team members in an environment that both respects and encourages diversity.

  13. Evaluating Job Demands and Control Measures for Use in Farm Worker Health Surveillance

    Science.gov (United States)

    Alterman, Toni; Gabbard, Susan; Grzywacz, Joseph G.; Shen, Rui; Li, Jia; Nakamoto, Jorge; Carroll, Daniel J.; Muntaner, Carles

    2015-01-01

    Workplace stress likely plays a role in health disparities; however, applying standard measures to studies of immigrants requires thoughtful consideration. The goal of this study was to determine the appropriateness of two measures of occupational stressors (‘decision latitude’ and ‘job demands’) for use with mostly immigrant Latino farm workers. Cross-sectional data from a pilot module containing a four-item measure of decision latitude and a two-item measure of job demands were obtained from a subsample (N = 409) of farm workers participating in the National Agricultural Workers Survey. Responses to items for both constructs were clustered toward the low end of the structured response-set. Percentages of responses of ‘very often’ and ‘always’ for each of the items were examined by educational attainment, birth country, dominant language spoken, task, and crop. Cronbach’s α, when stratified by subgroups of workers, for the decision latitude items were (0.65–0.90), but were less robust for the job demands items (0.25–0.72). The four-item decision latitude scale can be applied to occupational stress research with immigrant farm workers, and potentially other immigrant Latino worker groups. The short job demands scale requires further investigation and evaluation before suggesting widespread use. PMID:25138138

  14. Evaluation of a surveillance case definition for anogenital warts, Kaiser Permanente northwest.

    Science.gov (United States)

    Naleway, Allison L; Weinmann, Sheila; Crane, Brad; Gee, Julianne; Markowitz, Lauri E; Dunne, Eileen F

    2014-08-01

    Most studies of anogenital wart (AGW) epidemiology have used large clinical or administrative databases and unconfirmed case definitions based on combinations of diagnosis and procedure codes. We developed and validated an AGW case definition using a combination of diagnosis codes and other information available in the electronic medical record (provider type, laboratory testing). We calculated the positive predictive value (PPV) of this case definition compared with manual medical record review in a random sample of 250 cases. Using this case definition, we calculated the annual age- and sex-stratified prevalence of AGW among individuals 11 through 30 years of age from 2000 through 2005. We identified 2730 individuals who met the case definition. The PPV of the case definition was 82%, and the average annual prevalence was 4.16 per 1000. Prevalence of AGW was higher in females compared with males in every age group, with the exception of the 27- to 30-year-olds. Among females, prevalence peaked in the 19- to 22-year-olds, and among males, the peak was observed in 23- to 26-year-olds. The case definition developed in this study is the first to be validated with medical record review and has a good PPV for the detection of AGW. The prevalence rates observed in this study were higher than other published rates, but the age- and sex-specific patterns observed were consistent with previous reports.

  15. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  16. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  17. Integrated Locomotor Function Tests for Countermeasure Evaluation

    Science.gov (United States)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Landsness, E. C.; Black, F. O.

    2005-01-01

    Following spaceflight crewmembers experience locomotor dysfunction due to inflight adaptive alterations in sensorimotor function. Countermeasures designed to mitigate these postflight gait alterations need to be assessed with a new generation of tests that evaluate the interaction of various sensorimotor sub-systems central to locomotor control. The goal of the present study was to develop new functional tests of locomotor control that could be used to test the efficacy of countermeasures. These tests were designed to simultaneously examine the function of multiple sensorimotor systems underlying the control of locomotion and be operationally relevant to the astronaut population. Traditionally, gaze stabilization has been studied almost exclusively in seated subjects performing target acquisition tasks requiring only the involvement of coordinated eye-head movements. However, activities like walking involve full-body movement and require coordination between lower limbs and the eye-head-trunk complex to achieve stabilized gaze during locomotion. Therefore the first goal of this study was to determine how the multiple, interdependent, full-body sensorimotor gaze stabilization subsystems are functionally coordinated during locomotion. In an earlier study we investigated how alteration in gaze tasking changes full-body locomotor control strategies. Subjects walked on a treadmill and either focused on a central point target or read numeral characters. We measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. In comparison to the point target fixation condition, the results of the number reading task showed that compensatory head pitch movements increased, peak head acceleration was reduced and knee flexion at heel-strike was increased. In a more recent study we investigated the

  18. Evaluation of field test equipment for halide and DOP testing

    International Nuclear Information System (INIS)

    Schreiber, K.L.; Kovach, J.L.

    1975-01-01

    The Nucon Testing Services Department, field testing at power reactor sites, has performed tests using R-11, R-12, and R-112 in conjunction with gas chromatographs and direct reading halide detectors. The field operational experience with these detector systems, thus sensitivity, precision, and manner of field calibration, are presented. Laboratory experiments regarding 3 H-tagged methyl iodide for in place leak testing of adsorber systems indicate a low hazard, high reliability process for leak testing in facilities where atmospheric cross contamination occurs. (U.S.)

  19. Management and Use of Director, Operational Test and Evaluation Funds

    National Research Council Canada - National Science Library

    2000-01-01

    ... and transferred a wide range of test and evaluation functions and resources, including the oversight of the test ranges and facilities, test investment, and sponsorship of many test related programs...

  20. Building test data from real outbreaks for evaluating detection algorithms.

    Science.gov (United States)

    Texier, Gaetan; Jackson, Michael L; Siwe, Leonel; Meynard, Jean-Baptiste; Deparis, Xavier; Chaudet, Herve

    2017-01-01

    Benchmarking surveillance systems requires realistic simulations of disease outbreaks. However, obtaining these data in sufficient quantity, with a realistic shape and covering a sufficient range of agents, size and duration, is known to be very difficult. The dataset of outbreak signals generated should reflect the likely distribution of authentic situations faced by the surveillance system, including very unlikely outbreak signals. We propose and evaluate a new approach based on the use of historical outbreak data to simulate tailored outbreak signals. The method relies on a homothetic transformation of the historical distribution followed by resampling processes (Binomial, Inverse Transform Sampling Method-ITSM, Metropolis-Hasting Random Walk, Metropolis-Hasting Independent, Gibbs Sampler, Hybrid Gibbs Sampler). We carried out an analysis to identify the most important input parameters for simulation quality and to evaluate performance for each of the resampling algorithms. Our analysis confirms the influence of the type of algorithm used and simulation parameters (i.e. days, number of cases, outbreak shape, overall scale factor) on the results. We show that, regardless of the outbreaks, algorithms and metrics chosen for the evaluation, simulation quality decreased with the increase in the number of days simulated and increased with the number of cases simulated. Simulating outbreaks with fewer cases than days of duration (i.e. overall scale factor less than 1) resulted in an important loss of information during the simulation. We found that Gibbs sampling with a shrinkage procedure provides a good balance between accuracy and data dependency. If dependency is of little importance, binomial and ITSM methods are accurate. Given the constraint of keeping the simulation within a range of plausible epidemiological curves faced by the surveillance system, our study confirms that our approach can be used to generate a large spectrum of outbreak signals.

  1. Building test data from real outbreaks for evaluating detection algorithms.

    Directory of Open Access Journals (Sweden)

    Gaetan Texier

    Full Text Available Benchmarking surveillance systems requires realistic simulations of disease outbreaks. However, obtaining these data in sufficient quantity, with a realistic shape and covering a sufficient range of agents, size and duration, is known to be very difficult. The dataset of outbreak signals generated should reflect the likely distribution of authentic situations faced by the surveillance system, including very unlikely outbreak signals. We propose and evaluate a new approach based on the use of historical outbreak data to simulate tailored outbreak signals. The method relies on a homothetic transformation of the historical distribution followed by resampling processes (Binomial, Inverse Transform Sampling Method-ITSM, Metropolis-Hasting Random Walk, Metropolis-Hasting Independent, Gibbs Sampler, Hybrid Gibbs Sampler. We carried out an analysis to identify the most important input parameters for simulation quality and to evaluate performance for each of the resampling algorithms. Our analysis confirms the influence of the type of algorithm used and simulation parameters (i.e. days, number of cases, outbreak shape, overall scale factor on the results. We show that, regardless of the outbreaks, algorithms and metrics chosen for the evaluation, simulation quality decreased with the increase in the number of days simulated and increased with the number of cases simulated. Simulating outbreaks with fewer cases than days of duration (i.e. overall scale factor less than 1 resulted in an important loss of information during the simulation. We found that Gibbs sampling with a shrinkage procedure provides a good balance between accuracy and data dependency. If dependency is of little importance, binomial and ITSM methods are accurate. Given the constraint of keeping the simulation within a range of plausible epidemiological curves faced by the surveillance system, our study confirms that our approach can be used to generate a large spectrum of outbreak

  2. Vascular access surveillance: case study of a false paradigm.

    Science.gov (United States)

    Paulson, William D; Moist, Louise; Lok, Charmaine E

    2013-01-01

    The hemodialysis vascular access surveillance controversy provides a case study of how enthusiasm for a new test or treatment can lead to adoption of a false paradigm. Paradigms are the beliefs and assumptions shared by those in a field of knowledge, and are commonly included in clinical practice guidelines. The guidelines of the National Kidney Foundation Kidney Disease Outcomes Quality Initiative recommend that arteriovenous vascular accesses undergo routine surveillance for detection and correction of stenosis. This recommendation is based on the paradigm that surveillance of access blood flow or dialysis venous pressure combined with correction of stenosis improves access outcomes. However, the quality of evidence that supports this paradigm has been widely criticized. We tested the validity of the surveillance paradigm by applying World Health Organization (WHO) criteria for evaluating screening tests to a literature review of published vascular access studies. These criteria include four components: undesired condition, screening test, intervention, and desired outcome. The WHO criteria show that surveillance as currently practiced fails all four components and provides little or no significant benefit, suggesting that surveillance is a false paradigm. Once a paradigm is established, however, challenges to its validity are usually resisted even as new evidence indicates the paradigm is not valid. Thus, it is paramount to apply rigorous criteria when developing guidelines. Regulators may help promote needed changes in paradigms when cost and safety considerations coincide. © 2013 Wiley Periodicals, Inc.

  3. Analysis to evaluate predictors of fiberboard aging to guide surveillance sampling for the 9975 life extension program

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Elizabeth J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Daugherty, William L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hackney, Elizabeth R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-05-09

    During surveillance of the 9975 shipping package at the Savannah River Site K-Area Complex, several package dimensions are recorded. The analysis described in this report shows that, based on the current data analysis, two of these measurements, Upper Assembly Outer Diameter (UAOD) and Upper Assembly Inside Height (UAIH), do not have statistically significant aging trends regardless of wattage levels. In contrast, this analysis indicates that the measurement of Air Shield Gap (ASGap) does show a significant increase with age. It appears that the increase is greater for high wattage containers, but this result is dominated by two measurements from high-wattage containers. For all three indicators, additional high-wattage, older containers need to be examined before any definitive conclusions can be reached. In addition, the current analysis indicates that ASGap measurements for low and medium wattage containers are increasing slowly over time. To reduce uncertainties and better capture the aging trend for these containers, additional low and medium wattage older containers should also be examined. Based on this analysis, surveillance guidance is to augment surveillance containers resulting from 3013 surveillance with 9975-focused sampling that targets older, high wattage containers and also includes some older, low and medium wattage containers. This focused sampling began in 2015 and will continue in 2016. The UAOD, UAIH and ASGap data are highly variable. It is possible that additional factors such as seasonal variation and packaging site location might reduce variability and be useful for focusing surveillance and predicting aging.

  4. Additional patient outcomes and pathways in evaluations of testing

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; McCaffery, Kirsten

    2009-01-01

    Before medical tests are introduced into practice, they should be properly evaluated. Randomized trials and other comprehensive evaluations of tests and test strategies can best be designed based on an understanding of how tests can benefit or harm patients. Tests primarily affect patients' health

  5. The surveillance error grid.

    Science.gov (United States)

    Klonoff, David C; Lias, Courtney; Vigersky, Robert; Clarke, William; Parkes, Joan Lee; Sacks, David B; Kirkman, M Sue; Kovatchev, Boris

    2014-07-01

    Currently used error grids for assessing clinical accuracy of blood glucose monitors are based on out-of-date medical practices. Error grids have not been widely embraced by regulatory agencies for clearance of monitors, but this type of tool could be useful for surveillance of the performance of cleared products. Diabetes Technology Society together with representatives from the Food and Drug Administration, the American Diabetes Association, the Endocrine Society, and the Association for the Advancement of Medical Instrumentation, and representatives of academia, industry, and government, have developed a new error grid, called the surveillance error grid (SEG) as a tool to assess the degree of clinical risk from inaccurate blood glucose (BG) monitors. A total of 206 diabetes clinicians were surveyed about the clinical risk of errors of measured BG levels by a monitor. The impact of such errors on 4 patient scenarios was surveyed. Each monitor/reference data pair was scored and color-coded on a graph per its average risk rating. Using modeled data representative of the accuracy of contemporary meters, the relationships between clinical risk and monitor error were calculated for the Clarke error grid (CEG), Parkes error grid (PEG), and SEG. SEG action boundaries were consistent across scenarios, regardless of whether the patient was type 1 or type 2 or using insulin or not. No significant differences were noted between responses of adult/pediatric or 4 types of clinicians. Although small specific differences in risk boundaries between US and non-US clinicians were noted, the panel felt they did not justify separate grids for these 2 types of clinicians. The data points of the SEG were classified in 15 zones according to their assigned level of risk, which allowed for comparisons with the classic CEG and PEG. Modeled glucose monitor data with realistic self-monitoring of blood glucose errors derived from meter testing experiments plotted on the SEG when compared to

  6. Influenza surveillance

    Directory of Open Access Journals (Sweden)

    Karolina Bednarska

    2016-04-01

    Full Text Available Influenza surveillance was established in 1947. From this moment WHO (World Health Organization has been coordinating international cooperation, with a goal of monitoring influenza virus activity, effective diagnostic of the circulating viruses and informing society about epidemics or pandemics, as well as about emergence of new subtypes of influenza virus type A. Influenza surveillance is an important task, because it enables people to prepare themselves for battle with the virus that is constantly mutating, what leads to circulation of new and often more virulent strains of influenza in human population. As vaccination is the most effective method of fighting the virus, one of the major tasks of GISRS is developing an optimal antigenic composition of the vaccine for the current epidemic season. European Influenza Surveillance Network (EISN has also developed over the years. EISN is running integrated epidemiological and virological influenza surveillance, to provide appropriate data to public health experts in member countries, to enable them undertaking relevant activities based on the current information about influenza activity. In close cooperation with GISRS and EISN are National Influenza Centres - national institutions designated by the Ministry of Health in each country.

  7. Surveillance Angels

    NARCIS (Netherlands)

    Rothkrantz, L.J.M.

    2014-01-01

    The use of sensor networks has been proposed for military surveillance and environmental monitoring applications. Those systems are composed of a heterogeneous set of sensors to observe the environment. In centralised systems the observed data will be conveyed to the control room to process the

  8. Effectiveness and Cost-benefit Evaluation of a Comprehensive Workers' Health Surveillance Program for Sustainable Employability of Meat Processing Workers.

    Science.gov (United States)

    van Holland, Berry J; Reneman, Michiel F; Soer, Remko; Brouwer, Sandra; de Boer, Michiel R

    2018-03-01

    Objective To evaluate the effectiveness of a comprehensive workers' health surveillance (WHS) program on aspects of sustainable employability and cost-benefit. Methods A cluster randomized stepped wedge trial was performed in a Dutch meat processing company from february 2012 until march 2015. In total 305 workers participated in the trial. Outcomes were retrieved during a WHS program, by multiple questionnaires, and from company registries. Primary outcomes were sickness absence, work ability, and productivity. Secondary outcomes were health, vitality, and psychosocial workload. Data were analyzed with linear and logistic multilevel models. Cost-benefit analyses from the employer's perspective were performed as well. Results Primary outcomes sickness absence (OR = 1.40), work ability (B = -0.63) and productivity (OR = 0.71) were better in the control condition. Secondary outcomes did not or minimally differ between conditions. Of the 12 secondary outcomes, the only outcome that scored better in the experimental condition was meaning of work (B = 0.18). Controlling for confounders did not or minimally change the results. However, our stepped wedge design did not enable adjustment for confounding in the last two periods of the trial. The WHS program resulted in higher costs for the employer on the short and middle term. Conclusions Primary outcomes did not improve after program implementation and secondary outcomes remained equal after implementation. The program was not cost-beneficial after 1-3 year follow-up. Main limitation that may have contributed to absence of positive effects may be program failure, because interventions were not deployed as intended.

  9. Integrated Test and Evaluation (ITE) Flight Test Series 4

    Science.gov (United States)

    Marston, Michael

    2016-01-01

    The integrated Flight Test 4 (FT4) will gather data for the UAS researchers Sense and Avoid systems (referred to as Detect and Avoid in the RTCA SC 228 ToR) algorithms and pilot displays for candidate UAS systems in a relevant environment. The technical goals of FT4 are to: 1) perform end-to-end traffic encounter test of pilot guidance generated by DAA algorithms; 2) collect data to inform the initial Minimum Operational Performance Standards (MOPS) for Detect and Avoid systems. FT4 objectives and test infrastructure builds from previous UAS project simulations and flight tests. NASA Ames (ARC), NASA Armstrong (AFRC), and NASA Langley (LaRC) Research Centers will share responsibility for conducting the tests, each providing a test lab and critical functionality. UAS-NAS project support and participation on the 2014 flight test of ACAS Xu and DAA Self Separation (SS) significantly contributed to building up infrastructure and procedures for FT3 as well. The DAA Scripted flight test (FT4) will be conducted out of NASA Armstrong over an eight-week period beginning in April 2016.

  10. A retrospective evaluation of proficiency testing, and rapid HIV test ...

    African Journals Online (AJOL)

    Background: Proficiency testing (PT) has been implemented as a form of External Quality Assurance (EQA) by the National HIV Reference Laboratory in Kenya since 2007 in order to monitor and improve on the quality of HIV testing and counselling HTC services. Objective: To compare concordance between National HIV ...

  11. Surveillance of transmitted HIV drug resistance using matched plasma and dried blood spot specimens from voluntary counseling and testing sites in Ho Chi Minh City, Vietnam, 2007-2008.

    Science.gov (United States)

    Duc, Nguyen Bui; Hien, Bui Thu; Wagar, Nick; Tram, Tran Hong; Giang, Le Truong; Yang, Chunfu; Wolfe, Mitchell I; Hien, Nguyen Tran; Tuan, Nguyen Anh

    2012-05-01

    During 2007-2008, surveillance of transmitted human immunodeficiency virus (HIV) drug resistance (TDR) was performed following World Health Organization guidance among clients with newly diagnosed HIV infection attending voluntary counseling and testing (VCT) sites in Ho Chi Minh City (HCMC), Vietnam. Moderate (5%-15%) TDR to nonnucleoside reverse-transcriptase inhibitors (NNRTIs) was observed among VCT clients aged 18-21 years. Follow-up surveillance of TDR in HCMC and other geographic regions of Vietnam is warranted. Data generated will guide the national HIV drug resistance surveillance strategy and support selection of current and future first-line antiretroviral therapy and HIV prevention programs.

  12. Evaluation of natural language processing from emergency department computerized medical records for intra-hospital syndromic surveillance

    Directory of Open Access Journals (Sweden)

    Pagliaroli Véronique

    2011-07-01

    Full Text Available Abstract Background The identification of patients who pose an epidemic hazard when they are admitted to a health facility plays a role in preventing the risk of hospital acquired infection. An automated clinical decision support system to detect suspected cases, based on the principle of syndromic surveillance, is being developed at the University of Lyon's Hôpital de la Croix-Rousse. This tool will analyse structured data and narrative reports from computerized emergency department (ED medical records. The first step consists of developing an application (UrgIndex which automatically extracts and encodes information found in narrative reports. The purpose of the present article is to describe and evaluate this natural language processing system. Methods Narrative reports have to be pre-processed before utilizing the French-language medical multi-terminology indexer (ECMT for standardized encoding. UrgIndex identifies and excludes syntagmas containing a negation and replaces non-standard terms (abbreviations, acronyms, spelling errors.... Then, the phrases are sent to the ECMT through an Internet connection. The indexer's reply, based on Extensible Markup Language, returns codes and literals corresponding to the concepts found in phrases. UrgIndex filters codes corresponding to suspected infections. Recall is defined as the number of relevant processed medical concepts divided by the number of concepts evaluated (coded manually by the medical epidemiologist. Precision is defined as the number of relevant processed concepts divided by the number of concepts proposed by UrgIndex. Recall and precision were assessed for respiratory and cutaneous syndromes. Results Evaluation of 1,674 processed medical concepts contained in 100 ED medical records (50 for respiratory syndromes and 50 for cutaneous syndromes showed an overall recall of 85.8% (95% CI: 84.1-87.3. Recall varied from 84.5% for respiratory syndromes to 87.0% for cutaneous syndromes. The

  13. Surveillance of antibiotic resistance

    Science.gov (United States)

    Johnson, Alan P.

    2015-01-01

    Surveillance involves the collection and analysis of data for the detection and monitoring of threats to public health. Surveillance should also inform as to the epidemiology of the threat and its burden in the population. A further key component of surveillance is the timely feedback of data to stakeholders with a view to generating action aimed at reducing or preventing the public health threat being monitored. Surveillance of antibiotic resistance involves the collection of antibiotic susceptibility test results undertaken by microbiology laboratories on bacteria isolated from clinical samples sent for investigation. Correlation of these data with demographic and clinical data for the patient populations from whom the pathogens were isolated gives insight into the underlying epidemiology and facilitates the formulation of rational interventions aimed at reducing the burden of resistance. This article describes a range of surveillance activities that have been undertaken in the UK over a number of years, together with current interventions being implemented. These activities are not only of national importance but form part of the international response to the global threat posed by antibiotic resistance. PMID:25918439

  14. Secure Video Surveillance System (SVSS) for unannounced safeguards inspections

    International Nuclear Information System (INIS)

    Galdoz, Erwin G.; Pinkalla, Mark

    2010-01-01

    The Secure Video Surveillance System (SVSS) is a collaborative effort between the U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC). The joint project addresses specific requirements of redundant surveillance systems installed in two South American nuclear facilities as a tool to support unannounced inspections conducted by ABACC and the International Atomic Energy Agency (IAEA). The surveillance covers the critical time (as much as a few hours) between the notification of an inspection and the access of inspectors to the location in facility where surveillance equipment is installed. ABACC and the IAEA currently use the EURATOM Multiple Optical Surveillance System (EMOSS). This outdated system is no longer available or supported by the manufacturer. The current EMOSS system has met the project objective; however, the lack of available replacement parts and system support has made this system unsustainable and has increased the risk of an inoperable system. A new system that utilizes current technology and is maintainable is required to replace the aging EMOSS system. ABACC intends to replace one of the existing ABACC EMOSS systems by the Secure Video Surveillance System. SVSS utilizes commercial off-the shelf (COTS) technologies for all individual components. Sandia National Laboratories supported the system design for SVSS to meet Safeguards requirements, i.e. tamper indication, data authentication, etc. The SVSS consists of two video surveillance cameras linked securely to a data collection unit. The collection unit is capable of retaining historical surveillance data for at least three hours with picture intervals as short as 1sec. Images in .jpg format are available to inspectors using various software review tools. SNL has delivered two SVSS systems for test and evaluation at the ABACC Safeguards Laboratory. An additional 'proto-type' system remains

  15. Improvement of risk informed surveillance test interval for the safety related instrument and control system of Ulchin units 3 and 4

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lee, Yun Hwan; Lee, Seung Joon; Han, Sang Hoon

    2012-05-01

    The purpose of this research is the development of various methodologies necessary for the licensing of the risk informed surveillance test interval(STI) improvement for the safety related I and C systems in UCN 3 and 4, for instance, reactor protection system (RPS), engineered safety features actuation system (ESFAS), ESF auxiliary relay cabinet (ARC), and core protection calculator (CPC). The technical adequacy of the methodology was sufficiently verified through the application to the following STI changes. o CPC channel functional test (change from 1 month to 3 months including safety channel and log power test) o RPS channel functional test (change from 1 month to 3 months) o RPS logic and trip channel test (change from 1 month to 3 months. 1 month for RPS manual actuation test) o ESFAS channel functional test (change from 1 month to 3 months) o ESFAS logic and trip channel test (change from 1 month to 3 months) o ESF auxiliary relay test (change from 1 month to 3 months with staggered test. Manual actuation at the ESF ARC is added as a backup of ESF actuation signals during emergency operation

  16. Improvement of risk informed surveillance test interval for the safety related instrumentation and control system of Yonggwang units 3 and 4

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lee, Yun Hwan; Lee, Seung Joon; Han, Sang Hoon

    2012-05-01

    The purpose of this research is the development of various methodologies necessary for the licensing of the risk informed surveillance test interval(STI) improvement for the safety related I and C systems in YGN 3 and 4, for instance, reactor protection system (RPS), engineered safety features actuation system (ESFAS), ESF auxiliary relay cabinet (ARC), and core protection calculator (CPC). The technical adequacy of the methodology was sufficiently verified through the application to the following STI changes. o CPC channel functional test (change from 1 month to 3 months including safety channel and log power test) o RPS channel functional test (change from 1 month to 3 months) o RPS logic and trip channel test (change from 1 month to 3 months. 1 month for RPS manual actuation test) o ESFAS channel functional test (change from 1 month to 3 months) o ESFAS logic and trip channel test (change from 1 month to 3 months) o ESF auxiliary relay test (change from 1 month to 3 months with staggered test. Manual actuation at the ESF ARC is added as a backup of ESF actuation signals during emergency operation

  17. Evaluation of mammographic surveillance services in women aged 40-49 years with a moderate family history of breast cancer: a single-arm cohort study.

    Science.gov (United States)

    Duffy, S W; Mackay, J; Thomas, S; Anderson, E; Chen, T H H; Ellis, I; Evans, G; Fielder, H; Fox, R; Gui, G; Macmillan, D; Moss, S; Rogers, C; Sibbering, M; Wallis, M; Warren, R; Watson, E; Whynes, D; Allgood, P; Caunt, J

    2013-03-01

    Women with a significant family history of breast cancer are often offered more intensive and earlier surveillance than is offered to the general population in the National Breast Screening Programme. Up to now, this strategy has not been fully evaluated. To evaluate the benefit of mammographic surveillance for women aged 40-49 years at moderate risk of breast cancer due to family history. The study is referred to as FH01. This was a single-arm cohort study with recruitment taking place between January 2003 and February 2007. Recruits were women aged women were offered annual mammography for at least 5 years and observed for the occurrence of breast cancer during the surveillance period. The age group 40-44 years was targeted so that they would still be aged women, 94% of whom were aged women aged 40-49 years with a significant family history of breast or ovarian cancer is both clinically effective in reducing breast cancer mortality and cost-effective. There is a need to further standardise familial risk assessment, to research the impact of digital mammography and to clarify the role of breast density in this population. National Research Register N0484114809. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 17, No. 11. See the HTA programme website for further project information.

  18. The passive hamstring stretch test: clinical evaluation.

    Science.gov (United States)

    Fisk, J W

    1979-03-28

    The passive hamstring stretch test is described. Using a modified goniometer it is shown that independent measurements taken by trained examiners approximate very closely to each other. This establishes the test as a valid objective measurement. The possible value of this test as a research tool in low back pain problems is discussed.

  19. Assessment of an outreach street-based HIV rapid testing programme as a strategy to promote early diagnosis: a comparison with two surveillance systems in Spain, 2008-2011.

    Science.gov (United States)

    Belza, M J; Hoyos, J; Fernández-Balbuena, S; Diaz, A; Bravo, M J; de la Fuente, L

    2015-04-09

    We assess the added value of a multisite, street-based HIV rapid testing programme by comparing its results to pre-existing services and assessing its potential to reduce ongoing transmission. Between 2008 and 2011, 8,923 individuals underwent testing. We compare outcomes with those of a network of 20 sexually transmitted infections (STI)/HIV clinics (EPI-VIH) and the Spanish National HIV Surveillance System (SNHSS); evaluate whether good visibility prompts testing and assess whether it reaches under-tested populations. 89.2% of the new infections were in men who have sex with men (MSM) vs 78.0% in EPI-VIH and 56.0% in SNHSS. 83.6% of the MSM were linked to care and 20.9% had VIH. 56.5% of the HIV-positive MSM tested because they happened to see the programme, 18.4% were previously untested and 26.3% had their last test ≥2 years ago. The programme provided linkage to care and early diagnosis mainly to MSM but attendees presented a lower HIV prevalence than EPI-VIH. From a cost perspective it would benefit from being implemented in locations highly frequented by MSM. Conversely, its good visibility led to reduced periods of undiagnosed infection in a high proportion of MSM who were not testing with the recommended frequency.

  20. Technical Evaluation of Oak Ridge Filter Test Facility

    CERN Document Server

    Kriskovich, J R

    2002-01-01

    Two evaluations of the Oak Ridge Department of Energy (DOE) Filter Test Facility (FTF) were performed on December 11 and 12, 2001, and consisted of a quality assurance and a technical evaluation. This report documents results of the technical evaluation.

  1. Multicenter evaluation of resistance patterns of Klebsiella pneumoniae, Escherichia coli, Salmonella spp and Shigella spp isolated from clinical specimens in Brazil: RESISTNET surveillance program

    Directory of Open Access Journals (Sweden)

    Carmen Paz Oplustil

    Full Text Available Surveillance programs are essential to detect the increase of antimicrobial resistance, and several different programs are being conducted in many countries. The RESISTNET is a surveillance program for bacterial resistance against several antimicrobial agents initiated in 1998 among Latin American countries. In Brazil, several centers were invited to join this surveillance and a total of 11 centers (6 from São Paulo and 5 from other states participated in the study. All results were analyzed using the WHONET program. A total of 894 Escherichia coli, 386 Klebsiella pneumoniae, 70 Shigella spp and 57 Salmonella spp strains were analyzed in this study from April, 1998, to April, 1999. Susceptibility testing was performed by the disk diffusion method using NCCLS 1998 guidelines for several different drugs. For all strains, imipenem was the most effective drug (100% of the strains were susceptible. Klebsiella pneumoniae presented a high resistance rate to ampicillin (96.4%. The rate of probable ESBL producers among K. pneumoniae strains was 36.3%, most of them being isolated from catheters (58.8%. Among all Escherichia coli strains analyzed, the highest resistance rate was found for trimethoprim/sulfamethoxazole (46.9% and the majority of the resistant strains were isolated from urine samples (47.8%. Among Salmonella spp, the resistance rates were low for all antibiotics tested. For Shigella spp strains there was a high resistance to trimethoprim/sulfamethoxazole (80.0%. No resistance to ceftriaxone was observed in these strains. Surveillance of antimicrobial resistance is critical for the successful management of infectious diseases. The results of this survey show significant resistance rates among these bacteria which are responsible for several types of human infections.

  2. Economic evaluation and budget impact analysis of the surveillance program for hepatocellular carcinoma in Thai chronic hepatitis B patients.

    Science.gov (United States)

    Sangmala, Pannapa; Chaikledkaew, Usa; Tanwandee, Tawesak; Pongchareonsuk, Petcharat

    2014-01-01

    The incidence rate and the treatment costs of hepatocellular carcinoma (HCC) are high, especially in Thailand. Previous studies indicated that early detection by a surveillance program could help by down-staging. This study aimed to compare the costs and health outcomes associated with the introduction of a HCC surveillance program with no program and to estimate the budget impact if the HCC surveillance program were implemented. A cost utility analysis using a decision tree and Markov models was used to compare costs and outcomes during the lifetime period based on a societal perspective between alternative HCC surveillance strategies with no program. Costs included direct medical, direct non-medical, and indirect costs. Health outcomes were measured as life years (LYs), and quality adjusted life years (QALYs). The results were presented in terms of the incremental cost-effectiveness ratio (ICER) in Thai THB per QALY gained. One- way and probabilistic sensitivity analyses were applied to investigate parameter uncertainties. Budget impact analysis (BIA) was performed based on the governmental perspective. Semi-annual ultrasonography (US) and semi-annual ultrasonography plus alpha-fetoprotein (US plus AFP) as the first screening for HCC surveillance would be cost-effective options at the willingness to pay (WTP) threshold of 160,000 THB per QALY gained compared with no surveillance program (ICER=118,796 and ICER=123,451 THB/QALY), respectively. The semi-annual US plus AFP yielded more net monetary benefit, but caused a substantially higher budget (237 to 502 million THB) than semi-annual US (81 to 201 million THB) during the next ten fiscal years. Our results suggested that a semi-annual US program should be used as the first screening for HCC surveillance and included in the benefit package of Thai health insurance schemes for both chronic hepatitis B males and females aged between 40-50 years. In addition, policy makers considered the program could be feasible

  3. Rinderpest surveillance

    International Nuclear Information System (INIS)

    2003-01-01

    Rinderpest is probably the most lethal virus disease of cattle and buffalo and can destroy whole populations; damaging economies; undermining food security and ruining the livelihood of farmers and pastoralists. The disease can be eradicated by vaccination and control of livestock movement. The Department of Technical Co-operation is sponsoring a programme, with technical support from the Joint FAO/IAEA Division to provide advice, training and materials to thirteen states through the 'Support for Rinderpest Surveillance in West Asia' project. (IAEA)

  4. Health surveillance

    International Nuclear Information System (INIS)

    1981-01-01

    The Code includes a number of requirements for the health surveillance of employees associated with the mining and milling of radioactive ores. This guideline is particularly directed at determining the level of fitness of employees and prospective employees, detecting any symptom which might contraindicate exposure to the environment encountered in mine/mill situations, examination of any employee who may have been exposed to radiation in excess of defined limits and the accumulation and provision of data on the health of employees

  5. Extended result reading window in lateral flow tests detecting exposure to Onchocerca volvulus: a new technology to improve epidemiological surveillance tools.

    Directory of Open Access Journals (Sweden)

    Allison Golden

    Full Text Available Onchocerciasis is a neglected tropical disease caused by infection with the parasite Onchocerca volvulus (Ov. An estimated 180 million people are at risk for Ov infection, and 37 million people are infected, mostly in Africa. A lateral flow-based assay to detect human IgG4 antibodies to the Ov-specific antigen Ov-16 was developed as a rapid tool to detect exposure to Ov. The test, when performed on 449 sera specimens from patients with microfiladermia and Ov-negative patients, has a sensitivity of 89.1% (95% confidence interval: 86.2%-92.0%, and specificity of 97% (95% confidence interval: 95.4%-98.6%. Because the intended use of the test is for surveillance, it is highly desirable to have a stable, long-lasting result. An extended read window is thus desirable for a high-volume, busy workflow and facilitates post-surveillance quality assurance. The main restriction on achieving an extended read window for this assay was the erythrocyte lysis that can alter the signal-to-noise ratio, especially in those with low IgG4 levels (weak positives. We describe a test housing that incorporates a user-independent feature driven by assay fluid and an expanding wick that detaches the blood separation membrane from the nitrocellulose used in the assay, but before hemolysis occurs. We demonstrated material functionality at extreme operational conditions (37°C, 80% relative humidity and a read window of a minimum of 70 days. The fluid-driven assay device performs equally as well with whole blood as with plasma, as demonstrated with 100 spiked clinical specimens (with a correlation coefficient of 0.96. We show a novel, inexpensive, and simple approach to actuating the detachment of the blood separation membrane from the nitrocellulose test with no impact on the performance characteristics of the test.

  6. Comparison of embrittlement trend curves to high fluence surveillance results

    International Nuclear Information System (INIS)

    Bogaert, A.S.; Gerard, R.; Chaouadi, R.

    2011-01-01

    In the regulatory justification of the integrity of the reactor pressure vessels (RPV) for long term operation, use is made of predictive formulas (also called trend curves) to evaluate the RPV embrittlement (expressed in terms of RTNDT shifts) in function of fluence, chemical composition and in some cases temperature, neutron flux or product form. It has been shown recently that some of the existing or proposed trend curves tend to underpredict high dose embrittlement. Due to the scarcity of representative surveillance data at high dose, some test reactor results were used in these evaluations and raise the issue of representativeness of the accelerated test reactor irradiations (dose rate effects). In Belgium the surveillance capsules withdrawal schedule was modified in the nineties in order to obtain results corresponding to 60 years of operation or more with the initial surveillance program. Some of these results are already available and offer a good opportunity to test the validity of the predictive formulas at high dose. In addition, advanced surveillance methods are used in Belgium like the Master Curve, increased tensile tests, and microstructural investigations. These techniques made it possible to show the conservatism of the regulatory approach and to demonstrate increased margins, especially for the first generation units. In this paper the surveillance results are compared to different predictive formulas, as well as to an engineering hardening model developed at SCK.CEN. Generally accepted property-to-property correlations are critically revisited. Conclusions are made on the reliability and applicability of the embrittlement trend curves. (authors)

  7. Niland Test Facility Startup Evaluation Task Force

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    The following team reports are included: systems, operation, control, and safety; instrumentation; brine chemistry and materials evaluation; reservoir assessment; environment; and contingency analysis. (MHR)

  8. Test and evaluation of pressure vessel materials

    International Nuclear Information System (INIS)

    Choi, Sun Pil; Hong, Jun Hwa; Nho, Kye Hoe; Han, Dae June; Chi, Se Hwan

    1985-01-01

    We have prepared a method for analyzing the Charpy impact test data, which is deduced from ''the standard anelastic solid equation''. The theoretical expression for the absorbed energy is in a form of W=Wsub(U)+(Wsub(R)-Wsub(U))/ [1+(ωtau) 2 ] showing the Debye characteristics and where tau is given by the Arrhenius equation; tau=tau 0 exp(ΔH/ksub(B)T). Four measurable parameters, at the present stage, can characterize the dynamic hehavior of cracking (Charpy impact result). They are the upper shelf energy(Wsub(R), the lower shelf energy (Wsub(U)), the activation energy of crack (ΔH, and wtau(0) where w tau(0) are the resonance frequency of the specimen and the jumping pre-exponential factor of propagating crack respectively. However the states of R (relaxed) and U (un-relaxed) should be defined from reasonable physical conditions in the future and it is possible that Wsub(U) is small enough to be taken as zero. The effects of irradiation, alloying elements, and heat treatment on the impact results should be interpreted as changes in the above characteristic parameters. The present method has been applied for weld metal of SA 508-2 irradiated up to a fluence of 4x10 18 n/cm 2 , E>1.0Mev, resulting in about 29% decrease in Wsub(R), negligible change in Wsub(U), 5.6 times increase in ωtau 0 , and no change in ΔH. This seems to indicate that irradiation degrades an average value of YOUNG's modulus so that cracks propagate more easily and it does not effect on breaking the lattice bond. However much more systematic analyses should be necessary for correct judgment. It is concluded that the present method is quite adequate for analyzing the Charpy impact data even though plastic deformation in the specimen was not considered separately so that the method should be applied for various cases in order to evaluate the proper trend of effects of irradiation, alloying elements, and heat treatment on the Charpy impact results. (Author)

  9. Evaluation of sanitary consequences of Chernobylsk accident in France. Epidemiological surveillance plan, state of knowledge, risks evaluation and perspectives; Evaluation des consequences sanitaires de l'accident de Tchernobyl en France. Dispositif de surveillance epidemiologique, etat des connaissances, evaluation des risques et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Verger, P.; Cherie-Challine, L

    2000-12-15

    This report jointly written by IPSN and InVS, reviews the sanitary consequences in France of the Chernobyl accident, which occurred in 1986. The first point is dedicated to a short presentation of the knowledge relative to the sanitary consequences of the Chernobyl accident in the high contaminated countries and to the risk factors of the thyroid cancer. Secondly, this report describes the main systems of epidemiological surveillance of health implemented in France in 1986 and in 1999, as well as the data of the incidence and mortality of thyroid cancer observed in France since 1975. In addition, this report presents an analysis of the risk of thyroid cancer related to radioactive contamination in France, for young people of less than 15 years of age who where living in 1986 in the highest contaminated areas of France (Eastern territories). For this purpose, the theoretical number of thyroid cancers in excess is evaluated for this population, on the basis of different available risk model. Finally starting from the results of risk assessment, there is a discussion about the relevance and the feasibility of different epidemiological methods in view of answering the questions related to the sanitary consequences of the Chernobyl accident. In conclusion, this report recommends to reinforce the surveillance of thyroid cancer in France. (author)

  10. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants; Desarrollo de proceso de sellado de capsulas para probetas de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R. [ININ, Km 36.5 Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  11. Hepatocellular Carcinoma Surveillance Among Cirrhotic Patients With Commercial Health Insurance.

    Science.gov (United States)

    Goldberg, David S; Valderrama, Adriana; Kamalakar, Rajesh; Sansgiry, Sujit S; Babajanyan, Svetlana; Lewis, James D

    2016-03-01

    To evaluate hepatocellular carcinoma (HCC) surveillance rates among commercially insured patients, and evaluate factors associated with compliance with surveillance recommendations. Most HCC occurs in patients with cirrhosis. American Association for the Study of Liver Diseases and European Association for the Study of the Liver guidelines each recommend biannual HCC surveillance for cirrhotic patients to diagnose HCC at an early, curable stage. However, compliance with these guidelines in commercially insured patients is unknown. We used the Truven Health Analytics databases from 2006 to 2010, using January 1, 2006 as the anchor date for evaluating outcomes. The primary outcome was continuous surveillance measure, defined as the proportion of time "up-to-date" with surveillance (PTUDS), with the 6-month interval immediately following each ultrasound categorized as "up-to-date." During a median follow-up of 22.9 (interquartile range, 16.3 to 33.9) months among 8916 cirrhotic patients, the mean PTUDS was 0.34 (SD, 0.29), and the median was 0.31 (interquartile range, 0.03 to 0.52). These values increased only modestly with inclusion of serum alpha-fetoprotein testing, contrast-enhanced abdominal computed tomographic scans or magnetic resonance imagings, and/or extension of up-to-date time to 12 months. Being diagnosed by a nongastroenterology provider and increasing age were significantly associated with decreased HCC surveillance (Psurveillance (Psurveillance rates remained low. HCC surveillance rates in commercially insured at-risk patients remain poor despite formalized guidelines, highlighting the need to develop interventions to improve surveillance rates.

  12. 25th Test and Evaluation National Conference

    Science.gov (United States)

    2009-03-05

    assembly area.] • Load Aircraft and Weapon Status Check. • Lineup for takeoff. – Execute Mission [R and A mission executed as requested by ground... sequential testing and the sharing of high-demand testing assets Negative impact on ability to successfully execute complex programs: Massive

  13. Empirical Evaluation of Directional-Dependence Tests

    Science.gov (United States)

    Thoemmes, Felix

    2015-01-01

    Testing of directional dependence is a method to infer causal direction that recently has attracted some attention. Previous examples by e.g. von Eye and DeShon (2012a) and extensive simulation studies by Pornprasertmanit and Little (2012) have demonstrated that under specific assumptions, directional-dependence tests can recover the true causal…

  14. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  15. Exploring the utility of cardiorespiratory fitness as a population health surveillance indicator for children and youth: An international analysis of results from the 20-m shuttle run test.

    Science.gov (United States)

    Lang, Justin J

    2018-02-01

    Emerging evidence has demonstrated the strong link between cardiorespiratory fitness and multiple aspects of health (i.e., physiological, physical, psychosocial, cognitive), independent of physical activity, among school-aged children and youth. Cardiorespiratory fitness is a trait that does not vary substantially from day-to-day, and provides an indication of recent physical activity levels, making it an important possible indicator of population health. Thus, the objective of this dissertation was to investigate the utility of cardiorespiratory fitness, measured using the 20-m shuttle run test, as a broad, holistic health indicator for population health surveillance among children and youth. To achieve this objective we completed 7 manuscripts, all prepared for submission to peer-reviewed, scientific journals: (1) Systematic review of the relationship between 20-m shuttle run performance and health indicators among children and youth. (2) Review of criterion-referenced standards for cardiorespiratory fitness: what percentage of 1 142 026 international children and youth are apparently healthy? (3) Cardiorespiratory fitness is associated with physical literacy in a large sample of Canadian children aged 8 to 12 years. (4) International variability in 20-m shuttle run performance in children and youth: Who are the fittest from a 50-country comparison? A systematic review with pooling of aggregate results. (5) Making a case for cardiorespiratory fitness surveillance among children and youth. (6) International normative 20-m shuttle run values from 1 142 026 children and youth representing 50 countries. (7) Temporal trends in the cardiorespiratory fitness of children and adolescents representing 19 high-income and upper middle-income countries between 1981 and 2014. Combined, this dissertation provides support for the importance of cardiorespiratory fitness for health surveillance among school-aged children and youth. Results from the international analysis

  16. Impact of two interventions on timeliness and data quality of an electronic disease surveillance system in a resource limited setting (Peru: a prospective evaluation

    Directory of Open Access Journals (Sweden)

    Quispe Jose A

    2009-03-01

    Full Text Available Abstract Background A timely detection of outbreaks through surveillance is needed in order to prevent future pandemics. However, current surveillance systems may not be prepared to accomplish this goal, especially in resource limited settings. As data quality and timeliness are attributes that improve outbreak detection capacity, we assessed the effect of two interventions on such attributes in Alerta, an electronic disease surveillance system in the Peruvian Navy. Methods 40 Alerta reporting units (18 clinics and 22 ships were included in a 12-week prospective evaluation project. After a short refresher course on the notification process, units were randomly assigned to either a phone, visit or control group. Phone group sites were called three hours before the biweekly reporting deadline if they had not sent their report. Visit group sites received supervision visits on weeks 4 & 8, but no phone calls. The control group sites were not contacted by phone or visited. Timeliness and data quality were assessed by calculating the percentage of reports sent on time and percentage of errors per total number of reports, respectively. Results Timeliness improved in the phone group from 64.6% to 84% in clinics (+19.4 [95% CI, +10.3 to +28.6]; p Conclusion Regular phone reminders significantly improved timeliness of reports in clinics and ships, whereas supervision visits led to improved data quality only among clinics. Further investigations are needed to establish the cost-effectiveness and optimal use of each of these strategies.

  17. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  18. Cold test for bean seed vigor evaluation

    OpenAIRE

    Miguel, Marcelo Hissnauer; Cicero, Silvio Moure

    1999-01-01

    O presente trabalho teve como objetivo estudar o comportamento de sementes de feijão submetidas a diferentes metodologias do teste de frio, comparativamente a outros testes de vigor tradicionalmente utilizados na avaliação da qualidade fisiológica dessas sementes. As metodologias do teste de frio utilizadas foram: caixa plástica com terra, rolo de papel com terra e rolo de papel sem terra, nas temperaturas de 10ºC e de 15ºC e períodos de exposição, de três, cinco e sete dias. Paralelamente fo...

  19. Coanda hydro intake screen testing and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, J.

    2001-07-01

    The objective of this project has been to evaluate the effectiveness, suitability and cost benefit of the Aquashear Coanda effect, maintenance free intake screen for use in small hydro system intakes. (author)

  20. Surveillance of the environmental radioactivity

    International Nuclear Information System (INIS)

    Schneider, Th.; Gitzinger, C.; Jaunet, P.; Eberbach, F.; Clavel, B.; Hemidy, P.Y.; Perrier, G.; Kiper, Ch.; Peres, J.M.; Josset, M.; Calvez, M.; Leclerc, M.; Leclerc, E.; Aubert, C.; Levelut, M.N.; Debayle, Ch.; Mayer, St.; Renaud, Ph.; Leprieur, F.; Petitfrere, M.; Catelinois, O.; Monfort, M.; Baron, Y.; Target, A.

    2008-01-01

    The objective of these days was to present the organisation of the surveillance of the environmental radioactivity and to allow an experience sharing and a dialog on this subject between the different actors of the radiation protection in france. The different presentations were as follow: evolution and stakes of the surveillance of radioactivity in environment; the part of the European commission, regulatory aspects; the implementation of the surveillance: the case of Germany; Strategy and logic of environmental surveillance around the EDF national centers of energy production; environmental surveillance: F.B.F.C. site of Romans on Isere; steps of the implementation 'analysis for release decree at the F.B.F.C./C.E.R.C.A. laboratory of Romans; I.R.S.N. and the environmental surveillance: situation and perspectives; the part of a non institutional actor, the citizenship surveillance done by A.C.R.O.; harmonization of sampling methods: the results of inter operators G.T. sampling; sustainable observatory of environment: data traceability and samples conservation; inter laboratories tests of radioactivity measurements; national network of environmental radioactivity measurement: laboratories agreements; the networks of environmental radioactivity telemetry: modernization positioning; programme of observation and surveillance of surface environment and installations of the H.A.-M.A.V.L. project (high activity and long life medium activity); Evolution of radionuclides concentration in environment and adaptation of measurements techniques to the surveillance needs; the national network of radioactivity measurement in environment; modes of data restoration of surveillance: the results of the Loire environment pilot action; method of sanitary impacts estimation in the area of ionizing radiations; the radiological impact of atmospheric nuclear tests in French Polynesia; validation of models by the measure; network of measurement and alert management of the atmospheric

  1. Test report : alternative fuels propulsion durability evaluation

    Science.gov (United States)

    2012-08-28

    This document, prepared by Honeywell Aerospace, Phoenix, AZ (Honeywell), contains the final : test report (public version) for the U.S. Department of Transportation/Federal Aviation : Administration (USDOT/FAA) Alternative Fuels Propulsion Engine Dur...

  2. SDU6 Interior Liner Testing & Evaluation

    International Nuclear Information System (INIS)

    Skidmore, T. E.

    2016-01-01

    Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

  3. Evaluation of Mycology Laboratory Proficiency Testing

    OpenAIRE

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient te...

  4. SDU6 Interior Liner Testing & Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Skidmore, T. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-10-14

    Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warping or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.

  5. Surveyor mobile surveillance system for hazardous environments

    International Nuclear Information System (INIS)

    Silverman, E.B.; Simmons, R.K.; Kniazewycz, B.G.; Darvish, A.R.; Irving, T.L.

    1987-01-01

    A successful program was recently conducted to test and evaluate a commercial-ready, wireless, remotely operated surveillance system for use in nuclear power plants. This evaluation of the Surveyor mobile surveillance system took place at Niagara Mohawk Power Corporation's Nine Mile Point Nuclear Power Station. The remotely operated vehicle measures radiation, temperature and relative humidity and provides optical inspection capability. The vehicle is readily maneuvered in 36-inch wide passageways and labyrinth entries and can climb stairs, negotiating 180-degree turns on stair landings. The system consists of a supervisory control station and a rugged, remotely-operated, battery-powered vehicle. The surveyor system is specifically designed to decrease personnel radiation exposure by supplementing the functions of an auxiliary operator or wealth physics technician to perform periodic component inspections inside particular areas within a nuclear power plant

  6. Uncertainty Evaluation of Residential Central Air-conditioning Test System

    Science.gov (United States)

    Li, Haoxue

    2018-04-01

    According to national standards, property tests of air-conditioning are required. However, test results could be influenced by the precision of apparatus or measure errors. Therefore, uncertainty evaluation of property tests should be conducted. In this paper, the uncertainties are calculated on the property tests of Xinfei13.6 kW residential central air-conditioning. The evaluation result shows that the property tests are credible.

  7. Using an Emergency Department Syndromic Surveillance System to Evaluate Reporting of Potential Rabies Exposures, Illinois, 2013-2015.

    Science.gov (United States)

    Bemis, Kelley; Frias, Mabel; Patel, Megan Toth; Christiansen, Demian

    Mandatory reporting of potential rabies exposures and initiation of postexposure prophylaxis (PEP) allow local health authorities to monitor PEP administration for errors. Our objectives were to use an emergency department (ED) syndromic surveillance system to (1) estimate reporting compliance for exposure to rabies in suburban Cook County, Illinois, and (2) initiate interventions to improve reporting and reassess compliance. We queried ED records from 45 acute care hospitals in Cook County and surrounding areas from January 1, 2013, through June 30, 2015, for chief complaints or discharge diagnoses pertaining to rabies, PEP, or contact with a wild mammal (eg, bat, raccoon, skunk, fox, or coyote). We matched patients with ≥1 ED visit for potential rabies exposure to people with potential rabies exposure reported to the Cook County Department of Public Health. We considered nonmatches to have unreported exposures. We then initiated active surveillance in July 2015, disseminated education on reporting requirements in August and September 2015, and reassessed reporting completeness from July 2015 through February 2016. Of 248 patients with rabies-related ED visits from January 2013 through June 2015, 63 (25.4%) were reported. After interventions were implemented to increase reporting compliance, 53 of 98 (54.1%) patients with rabies-related ED visits from July 2015 through February 2016 were reported. Patients with ED visits for potential rabies exposure were twice as likely to be reported postintervention than preintervention (risk ratio = 2.1; 95% CI, 1.6-2.8). The volume of potential rabies exposure cases reported to the health department from July 2015 through February 2016 increased by 252% versus the previous year. Potential rabies exposures and PEP initiation are underreported in suburban Cook County. ED syndromic surveillance records can be used to estimate reporting compliance and conduct active surveillance.

  8. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    Science.gov (United States)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. H5N1-SeroDetect EIA and rapid test: a novel differential diagnostic assay for serodiagnosis of H5N1 infections and surveillance.

    Science.gov (United States)

    Khurana, Surender; Sasono, Pretty; Fox, Annette; Nguyen, Van Kinh; Le, Quynh Mai; Pham, Quang Thai; Nguyen, Tran Hien; Nguyen, Thanh Liem; Horby, Peter; Golding, Hana

    2011-12-01

    Continuing evolution of highly pathogenic (HP) H5N1 influenza viruses in wild birds with transmission to domestic poultry and humans poses a pandemic threat. There is an urgent need for a simple and rapid serological diagnostic assay which can differentiate between antibodies to seasonal and H5N1 strains and that could provide surveillance tools not dependent on virus isolation and nucleic acid technologies. Here we describe the establishment of H5N1 SeroDetect enzyme-linked immunosorbent assay (ELISA) and rapid test assays based on three peptides in HA2 (488-516), PB1-F2 (2-75), and M2e (2-24) that are highly conserved within H5N1 strains. These peptides were identified by antibody repertoire analyses of H5N1 influenza survivors in Vietnam using whole-genome-fragment phage display libraries (GFPDLs). To date, both platforms have demonstrated high levels of sensitivity and specificity in detecting H5N1 infections (clade 1 and clade 2.3.4) in Vietnamese patients as early as 7 days and up to several years postinfection. H5N1 virus-uninfected individuals in Vietnam and the United States, including subjects vaccinated with seasonal influenza vaccines or with confirmed seasonal virus infections, did not react in the H5N1-SeroDetect assays. Moreover, sera from individuals vaccinated with H5N1 subunit vaccine with moderate anti-H5N1 neutralizing antibody titers did not react positively in the H5N1-SeroDetect ELISA or rapid test assays. The simple H5N1-SeroDetect ELISA and rapid tests could provide an important tool for large-scale surveillance for potential exposure to HP H5N1 strains in both humans and birds.

  10. Evaluation of the association of acute overshift change in pulmonary function and atopy using OSHA cotton dust surveillance data.

    Science.gov (United States)

    Jennison, E; Jacobs, R R

    1994-05-01

    OSHA surveillance data were collected for 769 individuals employed in four different cotton textile mills. Current workers were asked to complete a questionnaire about personal and family history of atopy or asthma. Both surveillance and survey data were available for 502 individuals. The prevalence of atopy in the population as reported by questionnaire was 18%, while asthma was reported by 4%. Dust levels at the four mills were in compliance with the cotton dust standard during the period of surveillance. No relationship was found between a self-reported history of atopy or asthma and the magnitude or frequency of acute overshift declines in forced expiratory volume during 1 second (FEV1). Nonsmokers had annual changes in FEV1 and forced vital capacity (FVC) comparable to nonexposed populations. In one of the four mills surveyed, annual declines in FEV1 and FVC for current smokers were significantly greater than declines for smokers in the other mills or the general smoking population (p effect was also observed for subjects who were categorized as atopic (p effect from exposure to the levels of cotton dust observed in these mills.

  11. Are We Digital Masters Or Captives? A Critical Evaluation Of Panoptic Versus Synoptic Effect Of Surveillance In Social Media

    Directory of Open Access Journals (Sweden)

    Erdem Öngün

    2014-12-01

    Full Text Available The era we are living in is the one where we are exposed to a massive attraction of social connectivity based widely on digital forms of media. The most common one of them is social media. Social media exposes us to a kind of virtual Panopticon where ‘the few’ watch ‘the many’ in architecture of surveillance. Another term related to surveillance is Synopticon, a system where ‘the many’ watch ‘the few’ in the “Viewer Society”.  In the light of the related literature of theory and practice in the area, the study aims at viewing social media tools and its users from a critical perspective in a descriptive manner. To be able to do this, the study develops a set of hypothetical questions whose answers are instrumented to find out whether there is truly such a thing as “Virtual Panopticon” or “Synopticon” and if so, to what extent and how the Panoptic versus Synoptic effect of social media are felt among its users in various applications in light of media and communication. Facebook, based on the current theoretical knowledge within the field of surveillance can be given as an example. The study concludes with an overview of both assumptions with further reflections and contemplations of the readers of the study, who implicitly or explicitly could also be the actors of social media as masters or captives.

  12. Field evaluation of two commercial mosquito traps baited with different attractants and colored lights for malaria vector surveillance in Thailand.

    Science.gov (United States)

    Ponlawat, Alongkot; Khongtak, Patcharee; Jaichapor, Boonsong; Pongsiri, Arissara; Evans, Brian P

    2017-08-07

    Sampling for adult mosquito populations is a means of evaluating the efficacy of vector control operations. The goal of this study was to evaluate and identify the most efficacious mosquito traps and combinations of attractants for malaria vector surveillance along the Thai-Myanmar border. In the first part of the study, the BG-Sentinel™ Trap (BGS Trap) and Centers for Disease Control and Prevention miniature light trap (CDC LT) baited with different attractants (BG-lure® and CO 2 ) were evaluated using a Latin square experimental design. The six configurations were BGS Trap with BG-lure, BGS Trap with BG-lure plus CO 2 , BGS Trap with CO 2 , CDC LT with BG-lure, CDC LT with BG lure plus CO 2 , and CDC LT with CO 2 . The second half of the study evaluated the impact of light color on malaria vector collections. Colors included the incandescent bulb, ultraviolet (UV) light-emitting diode (LED), green light stick, red light stick, green LED, and red LED. A total of 8638 mosquitoes consisting of 42 species were captured over 708 trap-nights. The trap types, attractants, and colored lights affected numbers of female anopheline and Anopheles minimus collected (GLM, P surveillance when baited with CO 2 and the BG-lure in combination and can be effectively used as the new gold standard technique for collecting malaria vectors in Thailand.

  13. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.

    1991-09-01

    Laser Surveillance System (LASSY) is a beam of laser light which scans a plane above the water or under-water in a spent-fuel pond. The system can detect different objects and estimates its coordinates and distance as well. LASSY can operate in stand-alone configuration or in combination with a video surveillance to trigger signal to a videorecorder. The recorded information on LASSY computer's disk comprises date, time, start and stop angle of detected alarm, the size of the disturbance indicated in number of deviated points and some other information. The information given by the laser system cannot be fully substituted by TV camera pictures since the scanning beam creates a horizontal surveillance plan. The engineered prototype laser system long-term field test has been carried out in Soluggia (Italy) and has shown its feasibility and reliability under the conditions of real spent fuel storage pond. The verification of the alarm table on the LASSY computer with the recorded video pictures of TV surveillance system confirmed that all alarm situations have been detected. 5 refs

  14. Testing and evaluation of eight decontamination chemicals

    International Nuclear Information System (INIS)

    Demmer, R.

    1994-09-01

    This report covers experimental work comparing eight different decontamination chemicals. Seven of these chemicals have some novelty, or are not currently in use at the ICPP. The eighth is a common ICPP decontamination reagent used as a baseline for effective comparison. Decontamination factors, waste generation values, and corrosion rates are tabulated for these chemicals. Recommendations are given for effective methods of non-sodium or low-sodium decontamination chemicals. The two most effective chemical for decontamination found in these test were a dilute hydrofluoric and nitric acid (HF/HNO 3 ) mixture and a fluoroboric acid solution. The fluoroboric acid solution (1 molar) was by far the most effective decontamination reagent, but suffered the problem of generating significant final calcine volume. The HF/HNO 3 solution performed a very good decontamination of the SIMCON coupons while generating only small amounts of calcine volume. Concentration variables were also tested, and optimized for these two solutions. Several oxidation/reduction decon chemical systems were also tested. These systems were similar to the TURCO 4502 and TURCO 4521 solutions used for general decontamination at the ICPP. A low sodium alternative, nitric acid/potassium permanganate, to the ''high sodium'' TURCO 4502 was tested extensively, optimized and recommended for general ICPP use. A reductive chemical solution, oxalic acid/nitric acid was also shown to have significant advantages

  15. OCOD-CTTP Test Evaluation Report.

    Science.gov (United States)

    Shorey, Leonard

    Tests in social studies and integrated science given in Saint Vincent, Saint Lucia, Grenada, and Dominica were analyzed by the Organization for Co-operation in Overseas Development (OCOD) Comprehensive Teacher Training Program (CTTP) for discrimination, difficulty, and reliability, as well as other characteristics. There were 767 examinees for the…

  16. [Evaluation of pendulum testing of spasticity].

    Science.gov (United States)

    Le Cavorzin, P; Hernot, X; Bartier, O; Carrault, G; Chagneau, F; Gallien, P; Allain, H; Rochcongar, P

    2002-11-01

    To identify valid measurements of spasticity derived from the pendulum test of the leg in a representative population of spastic patients. Pendulum testing was performed in 15 spastic and 10 matched healthy subjects. The reflex-mediated torque evoked in quadriceps femoris, as well as muscle mechanical parameters (viscosity and elasticity), were calculated using mathematical modelling. Correlation with the two main measures derived from the pendulum test reported in the literature (the Relaxation Index and the area under the curve) was calculated in order to select the most valid. Among mechanical parameters, only viscosity was found to be significantly higher in the spastic group. As expected, the computed integral of the reflex-mediated torque was found to be larger in spastics than in healthy subjects. A significant non-linear (logarithmic) correlation was found between the clinically-assessed muscle spasticity (Ashworth grading) and the computed reflex-mediated torque, emphasising the non-linear behaviour of this scale. Among measurements derived from the pendulum test which are proposed in the literature for routine estimation of spasticity, the Relaxation Index exhibited an unsuitable U-shaped pattern of variation with increasing reflex-mediated torque. On the opposite, the area under the curve revealed a linear regression, which is more convenient for routine estimation of spasticity. The pendulum test of the leg is a simple technique for the assessment of spastic hypertonia. However, the measurement generally used in the literature (the Relaxation Index) exhibits serious limitations, and would benefit to be replaced by more valid measures, such as the area under the goniometric curve, especially for the assessment of therapeutics.

  17. Reactor Vessel Surveillance Program for Advanced Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Kyeong-Hoon; Kim, Tae-Wan; Lee, Gyu-Mahn; Kim, Jong-Wook; Park, Keun-Bae; Kim, Keung-Koo

    2008-10-15

    This report provides the design requirements of an integral type reactor vessel surveillance program for an integral type reactor in accordance with the requirements of Korean MEST (Ministry of Education, Science and Technology Development) Notice 2008-18. This report covers the requirements for the design of surveillance capsule assemblies including their test specimens, test block materials, handling tools, and monitors of the surveillance capsule neutron fluence and temperature. In addition, this report provides design requirements for the program for irradiation surveillance of reactor vessel materials, a layout of specimens and monitors in the surveillance capsule, procedures of installation and retrieval of the surveillance capsule assemblies, and the layout of the surveillance capsule assemblies in the reactor.

  18. An Evaluation of the National Malaria Surveillance System of Bhutan, 2006-2012, as it Approaches the Goal of Malaria Elimination

    Directory of Open Access Journals (Sweden)

    Nicole West

    2016-08-01

    Full Text Available Introduction: Bhutan is progressing towards malaria elimination. The purpose of this evaluation was to assess the ability of the surveillance system from 2006-2012 to meet the objectives of the Bhutan Vector-borne Disease Control Programme (VDCP and to highlight priorities requiring attention as the nation transitions to elimination.Methods: The evaluation was conducted using the Center for Disease Control guidelines for evaluating public health surveillance systems. Data sources included a search of publically available literature, VDCP program data, and interviews with malaria surveillance personnel. Blood slide quality assurance and control through formal assessment of slide preparation and measures of between reader correlation was performed. Results: Total malaria cases declined from 2006-2012. The average slide positivity rate decreased from 3.4% in 2006 to 0.2% in 2012. The proportion of non-residents in all cases increased to its highest value of 22.6% in 2012, and significant clustering in the border regions of India was noted, with Sarpang accounting for more cases than any other district from 2009 onward. Case detection was almost exclusively passive, but flexibility and sensitivity was demonstrated by the later addition of active case detection and specification of imported and locally-acquired cases. Spatial data was limited to the village level, not allowing identification of transmission hotspots. For blood smears, statistical measures of between reader agreement and predictive value were not computed. Blood smear quality was suboptimal by at least one criteria in over half of evaluated smears. Timeliness in reporting of cases was on a weekly to monthly basis, and did not meet the WHO goal of immediate notification.Conclusions: As of 2012, the national malaria surveillance system demonstrated flexibility, representativeness, simplicity, and stability. The full potential for data analysis was not yet realized. Attaining the goal of

  19. Nanostructural evolution in surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Toyama, T.; Nagai, Y.; Tang, Z.; Hasegawa, M.; Almazouzi, A.; Walle, E. van; Gerard, R.

    2007-01-01

    The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of in-service commercial nuclear reactor pressure vessel steel welds of Doel-1 and Doel-2 are revealed by combining the three-dimensional local electrode atom probe and positron annihilation techniques. In both medium (0.13 wt.%) and high (0.30 wt.%) Cu welds, the CRNPs are found to form readily at the very beginning of the reactor lifetime. Thereafter, during the subsequent 30 years of operation, the residual Cu concentration in the matrix shows a slight decrease while the CRNPs coarsen. On the other hand, small vacancy clusters of V 3 -V 4 start appearing after the initial Cu precipitation and accumulate steadily with increasing neutron dose. The observed nanostructural evolution is shown to provide unique and fundamental information about the mechanisms of the irradiation-induced embrittlement of these specific materials

  20. Development of methodologies for optimization of surveillance testing and maintenance of safety related equipment at NPPs. Report of a research coordination meeting. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    This report summarizes the results of the first meeting of the Coordinated Research Programme (CRP) on Development of Methodologies for Optimization of Surveillance Testing and Maintenance of Safety Related Equipment at NPPs, held at the Agency Headquarters in Vienna, from 16 to 20 December 1996. The purpose of this Research Coordination Meeting (RCM) was that all Chief Scientific Investigators of the groups participating in the CRP presented an outline of their proposed research projects. Additionally, the participants discussed the objective, scope, work plan and information channels of the CRP in detail. Based on these presentations and discussions, the entire project plan was updated, completed and included in this report. This report represents a common agreed project work plan for the CRP. Refs, figs, tabs.

  1. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  2. The evaluation and impact of diagnostic tests

    International Nuclear Information System (INIS)

    Royal, H.D.; McNeil, B.J.

    1989-01-01

    The authors describe the usefulness of the techniques that are applied to study the role of tests and point out their limitations. In many instances, complex tasks must be oversimplified in order to use currently available analytic tools. Certain tools, such as decision analysis, are useful not only because they can provide insight regarding the most favorable diagnostic/therapeutic strategies but also because they can identify areas where present knowledge is inadequate and thereby help put priorities on areas of research

  3. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  4. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  5. Management and Use of Director, Operational Test and Evaluation Funds

    National Research Council Canada - National Science Library

    2000-01-01

    .... The reorganization disestablished the functions of the Director, Test, Systems Engineering, and Evaluation, within the Office of Under Secretary of Defense for Acquisition, Technology, and Logistics...

  6. Evaluation of a continuous indicator for syndromic surveillance through simulation. application to vector borne disease emergence detection in cattle using milk yield.

    Directory of Open Access Journals (Sweden)

    Aurélien Madouasse

    Full Text Available Two vector borne diseases, caused by the Bluetongue and Schmallenberg viruses respectively, have emerged in the European ruminant populations since 2006. Several diseases are transmitted by the same vectors and could emerge in the future. Syndromic surveillance, which consists in the routine monitoring of indicators for the detection of adverse health events, may allow an early detection. Milk yield is routinely measured in a large proportion of dairy herds and could be incorporated as an indicator in a surveillance system. However, few studies have evaluated continuous indicators for syndromic surveillance. The aim of this study was to develop a framework for the quantification of both disease characteristics and model predictive abilities that are important for a continuous indicator to be sensitive, timely and specific for the detection of a vector-borne disease emergence. Emergences with a range of spread characteristics and effects on milk production were simulated. Milk yields collected monthly in 48 713 French dairy herds were used to simulate 576 disease emergence scenarios. First, the effect of disease characteristics on the sensitivity and timeliness of detection were assessed: Spatio-temporal clusters of low milk production were detected with a scan statistic using the difference between observed and simulated milk yields as input. In a second step, the system specificity was evaluated by running the scan statistic on the difference between observed and predicted milk yields, in the absence of simulated emergence. The timeliness of detection depended mostly on how easily the disease spread between and within herds. The time and location of the emergence or adding random noise to the simulated effects had a limited impact on the timeliness of detection. The main limitation of the system was the low specificity i.e. the high number of clusters detected from the difference between observed and predicted productions, in the absence of

  7. Evaluation of screening tests for colorectal cancer.

    Science.gov (United States)

    Bolt, R J

    1980-12-01

    The following guidelines are proposed for the asymptomatic patient representing for routine examination. Instruct the patient to eat All Bran cereal or a similar product for breakfast for three consecutive days prior to the day of appointment. At the time of appointment the stool obtained from rectal examination or from a spontaneous bowel movement is checked for occult blood using the guaiac method. If the findings are negative, no further tests are recommended. If positive, the patient is given complete dietary instructions in a non-meat, high-residue diet with avoidance of beets, horseradish, vitamins, or aspirin-containing compounds. The patient is then given six Hemoccult or Quikcult slides and is instructed to prepare two fecal slides from each stool specimen daily for three days. If these are all negative when tested, no further studies are necessary. If one or more are positive, however, sigmoidoscopic examination and colon and upper gastrointestinal radiography should be carried out in that order. Evidence that early lesions (Duke A or B) are detected and the cure rate improved with this procedure is quite convincing.

  8. Evaluation of ring tensile test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Anantharaman, S.; Balakrishnan, K.S.; Sivaramakrish, K.S.

    1990-01-01

    Ring specimens of 5-mm width cut from Zircaloy-2 cladding of reactor operated fuel elements that had experienced 5000 to 15,000 MWD/T of fuel burnup were subjected to ring tensile testing. The true stress-true strain data points up to the onset of necking from the individual load-elongation curves of these specimens were used as input data in Voce's equation. The results reveal that the uniform elongation (UE) values generated using Voce's equation were within (UE-2)% of the experimental percent uniform elongation (UE%). The corresponding ultimate tensile strength values were within ±1%. The uncertainty inherently associated in the determination of gauge length introduces extraneous deformation in the rings tested. Previous results had shown that a 14% increase in cladding diameter caused the gauge length to increase by 40%. To simulate the contribution of extraneous deformation due to an increase in cladding diameter, an analysis of the variation of the tensile parameters (uniform elongation and ultimate tensile strength) due to increase in the gauge length in the range of 10 to 40% was carried out. The results are discussed

  9. Statistical adjustment of culture-independent diagnostic tests for trend analysis in the Foodborne Diseases Active Surveillance Network (FoodNet), USA.

    Science.gov (United States)

    Gu, Weidong; Dutta, Vikrant; Patrick, Mary; Bruce, Beau B; Geissler, Aimee; Huang, Jennifer; Fitzgerald, Collette; Henao, Olga

    2018-03-19

    Culture-independent diagnostic tests (CIDTs) are increasingly used to diagnose Campylobacter infection in the Foodborne Diseases Active Surveillance Network (FoodNet). Because CIDTs have different performance characteristics compared with culture, which has been used historically and is still used to diagnose campylobacteriosis, adjustment of cases diagnosed by CIDT is needed to compare with culture-confirmed cases for monitoring incidence trends. We identified the necessary parameters for CIDT adjustment using culture as the gold standard, and derived formulas to calculate positive predictive values (PPVs). We conducted a literature review and meta-analysis to examine the variability in CIDT performance and Campylobacter prevalence applicable to FoodNet sites. We then developed a Monte Carlo method to estimate test-type and site-specific PPVs with their associated uncertainties. The uncertainty in our estimated PPVs was largely derived from uncertainty about the specificity of CIDTs and low prevalence of Campylobacter in tested samples. Stable CIDT-adjusted incidences of Campylobacter cases from 2012 to 2015 were observed compared with a decline in culture-confirmed incidence. We highlight the lack of data on the total numbers of tested samples as one of main limitations for CIDT adjustment. Our results demonstrate the importance of adjusting CIDTs for understanding trends in Campylobacter incidence in FoodNet.

  10. Evaluating Syndromic surveillance systems at institutions of higher education (IHEs: A retrospective analysis of the 2009 H1N1 influenza pandemic at two universities

    Directory of Open Access Journals (Sweden)

    May Larissa

    2011-07-01

    Full Text Available Abstract Background Syndromic surveillance has been widely adopted as a real-time monitoring tool for timely response to disease outbreaks. During the second wave of the pH1N1 pandemic in Fall 2009, two major universities in Washington, DC collected data that were potentially indicative of influenza-like illness (ILI cases in students and staff. In this study, our objectives were three-fold. The primary goal of this study was to characterize the impact of pH1N1 on the campuses as clearly as possible given the data available and their likely biases. In addition, we sought to evaluate the strengths and weaknesses of the data series themselves, in order to inform these two universities and other institutions of higher education (IHEs about real-time surveillance systems that are likely to provide the most utility in future outbreaks (at least to the extent that it is possible to generalize from this analysis. Methods We collected a wide variety of data that covered both student ILI cases reported to medical and non-medical staff, employee absenteeism, and hygiene supply distribution records (from University A only. Communication data were retrieved from university broadcasts, university preparedness websites, and H1N1-related on campus media reports. Regional data based on the Centers for Disease Control and Prevention Outpatient Influenza-like Illness Surveillance Network (CDC ILINet surveillance network, American College Health Association (ACHA pandemic influenza surveillance data, and local Google Flu Trends were used as external data sets. We employed a "triangulation" approach for data analysis in which multiple contemporary data sources are compared to identify time patterns that are likely to reflect biases as well as those that are more likely to be indicative of actual infection rates. Results Medical personnel observed an early peak at both universities immediately after school began in early September and a second peak in early November

  11. Evaluating syndromic surveillance systems at institutions of higher education (IHEs): a retrospective analysis of the 2009 H1N1 influenza pandemic at two universities.

    Science.gov (United States)

    Zhang, Ying; May, Larissa; Stoto, Michael A

    2011-07-26

    Syndromic surveillance has been widely adopted as a real-time monitoring tool for timely response to disease outbreaks. During the second wave of the pH1N1 pandemic in Fall 2009, two major universities in Washington, DC collected data that were potentially indicative of influenza-like illness (ILI) cases in students and staff. In this study, our objectives were three-fold. The primary goal of this study was to characterize the impact of pH1N1 on the campuses as clearly as possible given the data available and their likely biases. In addition, we sought to evaluate the strengths and weaknesses of the data series themselves, in order to inform these two universities and other institutions of higher education (IHEs) about real-time surveillance systems that are likely to provide the most utility in future outbreaks (at least to the extent that it is possible to generalize from this analysis). We collected a wide variety of data that covered both student ILI cases reported to medical and non-medical staff, employee absenteeism, and hygiene supply distribution records (from University A only). Communication data were retrieved from university broadcasts, university preparedness websites, and H1N1-related on campus media reports. Regional data based on the Centers for Disease Control and Prevention Outpatient Influenza-like Illness Surveillance Network (CDC ILINet) surveillance network, American College Health Association (ACHA) pandemic influenza surveillance data, and local Google Flu Trends were used as external data sets. We employed a "triangulation" approach for data analysis in which multiple contemporary data sources are compared to identify time patterns that are likely to reflect biases as well as those that are more likely to be indicative of actual infection rates. Medical personnel observed an early peak at both universities immediately after school began in early September and a second peak in early November; only the second peak corresponded to patterns in

  12. Methodology implementation in order to evaluate the biological risks in the Centre for Research and Rehabilitation of Hereditary Ataxias of Cuba: a biosecurity surveillance method

    Directory of Open Access Journals (Sweden)

    Dailín Cobos Valdes

    2014-12-01

    Full Text Available Introduction: The Center for Research and Rehabilitation of Hereditary Ataxias faces biological risks. Nevertheless a Biosafety system was not yet implemented. Objective: To apply the methodology in order to evaluate these risks Materials and Methods: Interview with the researchers of the center and the use of the methodology for evaluating biological risks designed for Cobos, 2009. Results: Fifty-three biological risks were identified and evaluated, 32 as moderated, 18 as tolerable and 3 as trivial. Such classification are crucial to establish its management priorities and represent a way of surveillance in Biosafety field. Conclusion: The results of this research represent an essential factor for the Biosafety documentation development adapted to the Center and according to the legal basis in terms of biological safety in Cuba.

  13. Surveillance and Critical Theory

    Directory of Open Access Journals (Sweden)

    Christian Fuchs

    2015-09-01

    Full Text Available In this comment, the author reflects on surveillance from a critical theory approach, his involvement in surveillance research and projects, and the status of the study of surveillance. The comment ascertains a lack of critical thinking about surveillance, questions the existence of something called “surveillance studies” as opposed to a critical theory of society, and reflects on issues such as Edward Snowden’s revelations, and Foucault and Marx in the context of surveillance.

  14. Development of technology on the material surveillance of CANDU pressure tubes

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Kye Hoh; Han, Jung Hoh; Lee, Duk Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-05-01

    Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test equipments and test (DHCV, hydriding, grip and tensile specimen etc). 23 figs, 6 tabs, 59 refs. (Author).

  15. Development of technology on the material surveillance of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Noh, Kye Hoh; Han, Jung Hoh; Lee, Duk Hyun

    1995-05-01

    Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test equipments and test (DHCV, hydriding, grip and tensile specimen etc). 23 figs, 6 tabs, 59 refs. (Author)

  16. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  17. Surveillance robot for nuclear power plants

    International Nuclear Information System (INIS)

    White, J.R.; Harvey, H.W.; Satterlee, P.E. Jr.

    1985-01-01

    A demonstration project to determine the feasibility and cost-effectiveness of mobile surveillance robots in nuclear power plants is being conducted by the Remote Technology Corporation (REMOTEC) for the US Nuclear Regulatory Commission. Phase I of the project was completed in March 1984 and included a survey of currently used robotic equipment and the development of a robotics application methodology. Three Tennessee Valley Authority plants were analyzed to identify specific plant areas with a high potential for surveillance robotics. Based on these results, a number of robotic system applications were prepared and evaluated for cost-effectiveness. The system with the highest potential, a mobile surveillance robot, was selected for fabrication and in-plant demonstration testing in a phase II effort. The design, fabrication, and assembly of SURBOT has been completed and cold testing is in process. It will be installed at the Browns Ferry Nuclear Plant early in 1986 for demonstration testing. Current projections are that SURBOT can be used in approx.40 rooms within the auxiliary building and will have annual savings of over 100 person-rem exposure, 1000 sets of C-zone clothing, and 1000 person-hours of labor

  18. Clinical Microbiology Laboratories' Adoption of Culture-Independent Diagnostic Tests Is a Threat to Foodborne-Disease Surveillance in the United States.

    Science.gov (United States)

    Shea, Shari; Kubota, Kristy A; Maguire, Hugh; Gladbach, Stephen; Woron, Amy; Atkinson-Dunn, Robyn; Couturier, Marc Roger; Miller, Melissa B

    2017-01-01

    INTRODUCTIONIn November 2015, the Centers for Disease Control and Prevention (CDC) sent a letter to state and territorial epidemiologists, state and territorial public health laboratory directors, and state and territorial health officials. In this letter, culture-independent diagnostic tests (CIDTs) for detection of enteric pathogens were characterized as "a serious and current threat to public health surveillance, particularly for Shiga toxin-producing Escherichia coli (STEC) and Salmonella" The document says CDC and its public health partners are approaching this issue, in part, by "reviewing regulatory authority in public health agencies to require culture isolates or specimen submission if CIDTs are used." Large-scale foodborne outbreaks are a continuing threat to public health, and tracking these outbreaks is an important tool in shortening them and developing strategies to prevent them. It is clear that the use of CIDTs for enteric pathogen detection, including both antigen detection and multiplex nucleic acid amplification techniques, is becoming more widespread. Furthermore, some clinical microbiology laboratories will resist the mandate to require submission of culture isolates, since it will likely not improve patient outcomes but may add significant costs. Specimen submission would be less expensive and time-consuming for clinical laboratories; however, this approach would be burdensome for public health laboratories, since those laboratories would need to perform culture isolation prior to typing. Shari Shea and Kristy Kubota from the Association of Public Health Laboratories, along with state public health laboratory officials from Colorado, Missouri, Tennessee, and Utah, will explain the public health laboratories' perspective on why having access to isolates of enteric pathogens is essential for public health surveillance, detection, and tracking of outbreaks and offer potential workable solutions which will allow them to do this. Marc Couturier of

  19. Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation

    Science.gov (United States)

    2016-05-01

    ARL-TN-0756 ● MAY 2016 US Army Research Laboratory Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation...Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation by Clayton M Weiss Oak Ridge Institute for Science and Education...ORISE), Belcamp, MD Parimal J Patel Weapons and Materials Research Directorate, ARL Approved for public release; distribution is

  20. Results from 15years of quality surveillance for a National Indigenous Point-of-Care Testing Program for diabetes.

    Science.gov (United States)

    Shephard, Mark; Shephard, Anne; McAteer, Bridgit; Regnier, Tamika; Barancek, Kristina

    2017-12-01

    Diabetes is a major health problem for Australia's Aboriginal and Torres Strait Islander peoples. Point-of-care testing for haemoglobin A1c (HbA1c) has been the cornerstone of a long-standing program (QAAMS) to manage glycaemic control in Indigenous people with diabetes and recently, to diagnose diabetes. The QAAMS quality management framework includes monthly testing of quality control (QC) and external quality assurance (EQA) samples. Key performance indicators of quality include imprecision (coefficient of variation [CV%]) and percentage acceptable results. This paper reports on the past 15years of quality testing in QAAMS and examines the performance of HbA1c POC testing at the 6.5% cut-off recommended for diagnosis. The total number of HbA1c EQA results submitted from 2002 to 2016 was 29,093. The median imprecision for EQA testing by QAAMS device operators averaged 2.81% (SD 0.50; range 2.2 to 3.9%) from 2002 to 2016 and 2.44% (SD 0.22; range 2.2 to 2.9%) from 2009 to 2016. No significant difference was observed between the median imprecision achieved in QAAMS and by Australasian laboratories from 2002 to 2016 (p=0.05; two-tailed paired t-test) and from 2009 to 2016 (p=0.17; two-tailed paired t-test). For QC testing from 2009 to 2016, imprecision averaged 2.5% and 3.0% for the two levels of QC tested. Percentage acceptable results averaged 90% for QA testing from 2002 to 2016 and 96% for QC testing from 2009 to 2016. The DCA Vantage was able to measure a patient and an EQA sample with an HbA1c value close to 6.5% both accurately and precisely. HbA1c POC testing in QAAMS has remained analytically sound, matched the quality achieved by Australasian laboratories and met profession-derived analytical goals for 15years. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. A New Molecular Surveillance System for Leishmaniasis

    Science.gov (United States)

    Pandey, Kishor; Pandey, Basu Dev; Mallik, Arun Kumar; Acharya, Jyoti; Kato, Kentaro; Kaneko, Osamu; Ferreira, Pedro Eduardo

    2014-01-01

    Abstract. Presently, global efforts are being made to control and eradicate the deadliest tropical diseases through the improvement of adequate interventions. A critical point for programs to succeed is the prompt and accurate diagnosis in endemic regions. Rapid diagnostic tests (RDTs) are being massively deployed and used to improve diagnosis in tropical countries. In the present report, we evaluated the hypothesis of, after use for diagnosis, the reuse of the Leishmania RDT kit as a DNA source, which can be used downstream as a molecular surveillance and/or quality control tool. As a proof of principle, a polymerase chain reaction-based method was used to detect Leishmania spp. minicircle kinetoplast DNA from leishmaniasis RDT kits. Our results show that Leishmania spp. DNA can be extracted from used RDTs and may constitute an important, reliable, and affordable tool to assist in future leishmaniasis molecular surveillance methods. PMID:24752687

  2. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012

    DEFF Research Database (Denmark)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A

    2015-01-01

    BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data of patie......BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data...... of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. RESULTS......: Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance...

  3. Test facilities for evaluating nuclear thermal propulsion systems

    International Nuclear Information System (INIS)

    Beck, D.F.; Allen, G.C.; Shipers, L.R.; Dobranich, D.; Ottinger, C.A.; Harmon, C.D.; Fan, W.C.; Todosow, M.

    1992-01-01

    Interagency panels evaluating nuclear thermal propulsion (NTP) development options have consistently recognized the need for constructing a major new ground test facility to support fuel element and engine testing. This paper summarizes the requirements, configuration, and baseline performance of some of the major subsystems designed to support a proposed ground test complex for evaluating nuclear thermal propulsion fuel elements and engines being developed for the Space Nuclear Thermal Propulsion (SNTP) program. Some preliminary results of evaluating this facility for use in testing other NTP concepts are also summarized

  4. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  5. Instruments for non-destructive evaluation of advanced test reactor inpile tubes

    International Nuclear Information System (INIS)

    Livingston, R.A.; Beller, L.S.; Edgett, S.M.

    1986-01-01

    The Advanced Test Reactor is a 250 MW LWR used primarily for irradiation testing of materials contained in inpile tubes that pass through the reactor core. These tubes provided the high pressure and temperature water environment required for the test specimens. The reactor cooling water surrounding the inpile tubes is at much lower pressure and temperature. The structural integrity of the inpile tubes is monitored by routine surveillance to ensure against unplanned reactor shutdowns to replace defective inpile tubes. The improved instruments developed for inpile tube surveillance include a bore profilometer, ultrasonic flaw detetion system and bore diameter gauges. The design and function of these improved instruments is presented

  6. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  7. Cross-lingual tagger evaluation without test data

    DEFF Research Database (Denmark)

    Agic, Zeljko; Plank, Barbara; Søgaard, Anders

    2017-01-01

    We address the challenge of cross-lingual POS tagger evaluation in absence of manually annotated test data. We put forth and evaluate two dictionary-based metrics. On the tasks of accuracy prediction and system ranking, we reveal that these metrics are reliable enough to approximate test set-base......-based evaluation, and at the same time lean enough to support assessment for truly low-resource languages....

  8. Evaluation of LLTR series II test A-7 results

    International Nuclear Information System (INIS)

    Knittle, D.E.; Amos, J.C.; Yang, T.M.

    1981-09-01

    This report evaluates the test A-7 data and assesses the capability of the analytical methodology (as a result of Series I program) to predict the thermal/hydraulic phenomena associated with a large SWR event occurring after the sodium system pressure has increased to near the rupture disc burst pressure due to a smaller size leak event. Evaluation of intertest examination data to determine the extent of test article damage resulting from test A-7 is also included

  9. Test plan for FY-91 alpha CAM evaluation

    International Nuclear Information System (INIS)

    Winberg, M.R.

    1991-03-01

    This report describes the test plan for evaluating the Merlin Gerin, Inc., Edgar alpha continuous air monitor (CAM) and associated analysis system to be conducted by Idaho National Engineering Laboratory (INEL) for the Department of Energy. INEL has evaluated other commercial alpha CAM systems to detect transuranic contaminants during waste handling and retrieval operations. This test plan outlines experimental methods, sampling methods, sampling and analysis techniques, and equipment needed and safety and quality requirements to test the commercial CAM. 8 refs., 3 figs

  10. Evaluation of the finger wrinkling test: A pilot study

    NARCIS (Netherlands)

    van Barneveld, S.; van der Palen, Jacobus Adrianus Maria; van Putten, Michel Johannes Antonius Maria

    2010-01-01

    Purpose: Tilt table testing mainly evaluates the systemic cardiovascular part of the autonomic nervous system, while it is assumed that the finger wrinkling test assesses the peripheral part of the autonomic nervous system. In this study we explored whether the finger wrinkling test could be a

  11. The Evaluation of Diagnostic Tests for Sexually Transmitted Infections

    Directory of Open Access Journals (Sweden)

    Max A Chernesky

    2005-01-01

    Full Text Available Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis -- sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  12. Relationship between a Centers for Disease Control and Prevention expanded HIV testing initiative and past-year testing by race/ethnicity: a multilevel analysis of the Behavioral Risk Factor Surveillance System.

    Science.gov (United States)

    Gaines, Tommi L; Caldwell, Julia T; Ford, Chandra L; Mulatu, Mesfin S; Godette, Dionne C

    2016-01-01

    The Centers for Disease Control and Prevention's (CDC) expanded testing initiative (ETI) aims to bolster HIV testing among populations disproportionately affected by the HIV epidemic by providing additional funding to health departments serving these communities. ETI prioritizes testing in clinical settings; therefore, we examined the relationship between state-level ETI participation and past-year HIV testing among a racially/ethnically diverse sample of adult respondents to the 2012 Behavioral Risk Factor Surveillance System who accessed health services within the 12 months prior to being interviewed. Controlling for individual- and state-level characteristics in a multilevel logistic regression model, ETI participation was independently and positively associated with past-year testing, but this association varied by race/ethnicity. Hispanics had higher odds (adjusted odds ratio [AOR]: 1.49; 95% CI: 1.11-2.02) and American Indian/Alaska Natives had lower odds (AOR: 0.66; 95% CI: 0.43-0.99) of testing if they resided in states with (vs. without) ETI participation. State-level ETI participation did not significantly alter past-year testing among other racial/ethnic groups. Prioritizing public health resources in states most affected by HIV can improve testing patterns, but other mechanisms likely influence which racial/ethnic groups undergo testing.

  13. Safety of laboratory analyzers for infection testing - results of the market surveillance by the BfArM until end 2007

    Directory of Open Access Journals (Sweden)

    Siekmeier R

    2009-12-01

    Full Text Available Abstract The European Directive 98/79/EC on in vitro diagnostic medical devices (IVD stipulates the marketing and post market surveillance of IVD in the European Economic Area. In cases of issues and field corrective actions, the manufacturers have to inform the responsible Competent Authorities (CA. In Germany, the Federal Institute for Drugs and Medical Devices (BfArM is the responsible CA for most IVD, with a small subset of IVD for immune hematological and infectiological testing as well as tissue typing as specified in Annex II of the Directive, being within the responsibility of the Paul-Ehrlich-Institute (PEI. In this study, all issues regarding laboratory analyzers for infection testing and their consumables, but not reagents, kits and general culture media, reported to the BfArM between begin 1999 and end of 2007 were analyzed in respect to the sources of report, the underlying product failure and the performed corrective actions. Within the observation period a total of 1471 reports for IVD were received of which 73 related to the IVD for infection testing were included in our study. Reports were predominantly received from manufacturers (56 and competent authorities (15. Affected products were most frequently those for immunological analysis (42 whereas those based on culturing techniques (17 and molecular biological techniques (14 played only minor roles. In all these groups, laboratory analyzers (55 were more frequently affected than their consumables (18. Investigations of the manufacturers were able to identify the underlying root causes of product failures in 62 cases (84.9%. In 2 cases (2.7% the root cause remained unclear and in 9 cases (12.3% a product failure was excluded or a user error was the underlying cause. Product failures in laboratory analyzers were most frequently caused by software errors (31 and constructional faults (8 whereas the predominant cause of product failure in consumables were errors in production and

  14. HIV incidence in rural South Africa: comparison of estimates from longitudinal surveillance and cross-sectional cBED assay testing.

    Directory of Open Access Journals (Sweden)

    Till Bärnighausen

    Full Text Available The BED IgG-Capture Enzyme Immunoassay (cBED assay, a test of recent HIV infection, has been used to estimate HIV incidence in cross-sectional HIV surveys. However, there has been concern that the assay overestimates HIV incidence to an unknown extent because it falsely classifies some individuals with non-recent HIV infections as recently infected. We used data from a longitudinal HIV surveillance in rural South Africa to measure the fraction of people with non-recent HIV infection who are falsely classified as recently HIV-infected by the cBED assay (the long-term false-positive ratio (FPR and compared cBED assay-based HIV incidence estimates to longitudinally measured HIV incidence.We measured the long-term FPR in individuals with two positive HIV tests (in the HIV surveillance, 2003-2006 more than 306 days apart (sample size n = 1,065. We implemented four different formulae to calculate HIV incidence using cBED assay testing (n = 11,755 and obtained confidence intervals (CIs by directly calculating the central 95(th percentile of incidence values. We observed 4,869 individuals over 7,685 person-years for longitudinal HIV incidence estimation. The long-term FPR was 0.0169 (95% CI 0.0100-0.0266. Using this FPR, the cross-sectional cBED-based HIV incidence estimates (per 100 people per year varied between 3.03 (95% CI 2.44-3.63 and 3.19 (95% CI 2.57-3.82, depending on the incidence formula. Using a long-term FPR of 0.0560 based on previous studies, HIV incidence estimates varied between 0.65 (95% CI 0.00-1.32 and 0.71 (95% CI 0.00-1.43. The longitudinally measured HIV incidence was 3.09 per 100 people per year (95% CI 2.69-3.52, after adjustment to the sex-age distribution of the sample used in cBED assay-based estimation.In a rural community in South Africa with high HIV prevalence, the long-term FPR of the cBED assay is substantially lower than previous estimates. The cBED assay performs well in HIV incidence estimation if the locally

  15. HIV testing and intimate partner violence among non-pregnant women in 15 US states/territories: findings from behavioral risk factor surveillance system survey data.

    Science.gov (United States)

    Nasrullah, Muazzam; Oraka, Emeka; Breiding, Mathew J; Chavez, Pollyanna R

    2013-09-01

    Intimate partner violence (IPV) has been shown to be associated with higher rates of HIV infection among women, underscoring the importance of encouraging IPV victims to receive HIV testing. However, we do not know how much HIV testing behavior is influenced by IPV victimization. The current study characterized the association between individual types of IPV and HIV testing in a large sample of non-pregnant women in 15 US states/territories. The 2005 Behavioral Risk Factor Surveillance System data were analyzed after restricting the sample to non-pregnant women. The dependent variable, whether a woman ever had an HIV test, was examined in relation to individual types of IPV victimization (threatened physical violence; attempted physical violence; completed physical violence; and unwanted sex). Associations between HIV testing and types of IPV were assessed using adjusted risk ratios (aRR) that controlled for demographics and HIV-related risk factors (intravenous drug use, sexually transmitted diseases, exchange sex, unprotected anal sex). Approximately 28.6 % of women reported ever having experienced IPV, and 52.8 % of these women reported being tested for HIV. Among women who had not experienced IPV, 32.9 % reported ever having been tested for HIV. HIV testing was associated with lifetime experience of threatened violence (aRR = 1.43; 95 % CI = 1.24-1.65), attempted violence (aRR = 1.43; 95 % CI = 1.20-1.69), completed physical violence (aRR = 1.30; 95 % CI = 1.13-1.48), and unwanted sex (aRR = 1.66; 95 % CI = 1.48-1.86). Women who experienced each type of IPV were more likely to have been ever tested for HIV compared to women with no IPV history. However, nearly half of those reporting IPV, even though at greater risk for HIV infection, had never been tested. Additional efforts are needed to address barriers to testing in this group.

  16. Anxiety, Culture, and Expectations: Oncologist-Perceived Factors Associated With Use of Nonrecommended Serum Tumor Marker Tests for Surveillance of Early-Stage Breast Cancer.

    Science.gov (United States)

    Hahn, Erin E; Munoz-Plaza, Corrine; Wang, Jianjin; Garcia Delgadillo, Jazmine; Schottinger, Joanne E; Mittman, Brian S; Gould, Michael K

    2017-01-01

    Breast cancer offers several opportunities for reducing use of ineffective practices based on American Society of Clinical Oncology guidelines. We assessed oncologist-perceived factors associated with use of one such practice-serum tumor markers for post-treatment breast cancer surveillance-focusing on medical oncologists with high, medium, or low test use. Using a mixed-methods design, we identified patients who had been treated for early-stage breast cancer diagnosed between January 1, 2009, and December 31, 2012, within Kaiser Permanente Southern California and calculated the number of tests ordered from January 1, 2010, to December 31, 2014. We identified oncologists with high, medium, or low use and subsequently performed semistructured interviews. We used patient satisfaction data to assess association between pattern of use and satisfaction score. We identified 7,363 patients, with 40,114 tests ordered. High-use oncologists were defined as those ordering at least one test annually for 35% of patients or more, low-use oncologists as those ordering at least one test for 5% of patients or less; 42% of oncologists were high, 27% low, and 31% medium users. We interviewed 17 oncologists: six high, eight low, and three medium users. Factors associated with high use included: perceived patient anxiety, oncologist anxiety, belief that there was nothing else to offer, concern about satisfaction, patient competition, peer use, and system barriers. Factors associated with low use included: beliefs about consequences (eg, causes harms) and medical center culture (eg, collective decision to follow guidelines). We found no association between satisfaction score and pattern of use. Barriers to deimplementation are numerous and complex. Traditional strategies of practice change alone are unlikely to be effective. Multifaceted, multilevel strategies deployed to address patient-, clinician-, and system-related barriers may be required.

  17. Choosing the correct empirical antibiotic for urinary tract infection in pediatric: Surveillance of antimicrobial susceptibility pattern of Escherichia coli by E-Test method.

    Science.gov (United States)

    Sedighi, Iraj; Solgi, Abbas; Amanati, Ali; Alikhani, Mohammad Yousef

    2014-12-01

    Urinary Tract Infections (UTIs) are of the most common bacterial diseases worldwide. We investigate the antibiotic susceptibility patterns of Escherichia coli (E. coli) strains isolated from pediatric patients with community acquired urinary tract infection (UTI) to find a clinical guidance for choosing a right empirical antibiotic in these patients. In this cross sectional study, 100 urine specimens which were positive for E. coli had been investigated for antibiotics susceptibility pattern. The susceptibility to Co-trimoxazol (25μg), Amikacin (30μg), Ceftriaxone (30μg), Nalidixic Acid (30μg), Cefixime (5μg), and Nitrofurantoin (300μg) tested with Disk diffusion agar and MIC determined with the E-test. Mean age of patients was 38 Months. Girls had greater proportion than boys (74 versus 26%). In Disk diffusion method, 26% of the isolates were susceptible to cotrimoxazole. Susceptibility to amikacin, ceftriaxone, nitrofurantoin, nalidixic acid and cefixime was 94%, 66%, 97%, 62% and 52%, respectively. By E-Test method and according to CLSI criteria susceptibility for co-trimoxazol, amikacin, ceftriaxone and nalidixic acid was 37%, 97%, 67% and 50%, respectively. The highest percentage of agreement between Disk diffusion and E-Test method was found for amikacin (96%) and the lowest percentage for co-trimoxazole (89%). Treatment failure, prolonged or repeated hospitalization, increased costs of care, and increased mortality are some consequence of bacterial resistance in UTIs. Misuse of antibiotics in each geographic location directly affects antibiotic resistance pattern. In the treatment of UTI, proper selection of antimicrobial agents should be relevant to the bacterial susceptibility testing surveillance. According to our results, amikacin as an injectable drug and nitrofurantoin as an oral agent could be used as a drug of choice in our region for children with UTIs.

  18. Imaging tests in staging and surveillance of non-metastatic breast cancer: changes in routine clinical practice and cost implications.

    Science.gov (United States)

    De Placido, S; De Angelis, C; Giuliano, M; Pizzi, C; Ruocco, R; Perrone, V; Bruzzese, D; Tommasielli, G; De Laurentiis, M; Cammarota, S; Arpino, G; Arpino, G

    2017-03-14

    Although guidelines do not recommend computerised tomography (CT), positron emission tomography (PET) or magnetic resonance imaging (MRI) for the staging or follow-up of asymptomatic patients with non-metastatic breast cancer, they are often requested in routine clinical practice. The aim of this study was to determine the staging and follow-up patterns, and relative costs in a large population of breast cancer patients living and treated in a Southern Italian region. We analysed the clinical computerised information recorded by 567 primary-care physicians assisting about 650 000 inhabitants in the Campania region. Patients with non-metastatic breast cancer were identified and divided into calendar years from 2001 to 2010. The number of diagnostic tests prescribed per 100 patients (N/Pts) and the mean cost per patient was determined 3 months before diagnosis and up to 1 year after diagnosis. Costs are expressed in constant 2011 euros. We identified 4680 newly diagnosed cases of asymptomatic non-metastatic breast cancer. N/Pts increased significantly (Ptests'), and costs was unchanged. However, the number of CT, PET scans and MRI ('new tests')prescriptions almost quadrupled and the mean cost per patient related to these procedures significantly increased from [euro ]357 in 2001 to [euro ]830 in 2010 (Ptest prescriptions and relative costs significantly and steadily increased throughout the study period. At present there is no evidence that the delivery of new tests to asymptomatic patients improves breast cancer outcome. Well-designed clinical trials are urgently needed to shed light on the impact of these tests on clinical outcome and overall survival.

  19. Who is Surveilling Whom?

    DEFF Research Database (Denmark)

    Mortensen, Mette

    2014-01-01

    This article concerns the particular form of counter-surveillance termed “sousveillance”, which aims to turn surveillance at the institutions responsible for surveillance. Drawing on the theoretical perspectives “mediatization” and “aerial surveillance,” the article studies WikiLeaks’ publication...

  20. Surveillance of intestinal schistosomiasis during control: a comparison of four diagnostic tests across five Ugandan primary schools in the Lake Albert region.

    Science.gov (United States)

    Al-Shehri, Hajri; Koukounari, Artemis; Stanton, Michelle C; Adriko, Moses; Arinaitwe, Moses; Atuhaire, Aaron; Kabatereine, Narcis B; Stothard, J Russell

    2018-03-21

    Programmatic surveillance of intestinal schistosomiasis during control can typically use four diagnostic tests, either singularly or in combination, but these have yet to be cross-compared directly. Our study assembled a complete diagnostic dataset, inclusive of infection intensities, from 258 children from five Ugandan primary schools. The schools were purposely selected as typical of the endemic landscape near Lake Albert and reflective of high- and low-transmission settings. Overall prevalence was: 44.1% (95% CI 38.0-50.2) by microscopy of duplicate Kato-Katz smears from two consecutive stools, 56.9% (95% CI 50.8-63.0) by urine-circulating cathodic antigen (CCA) dipstick, 67.4% (95% CI 61.6-73.1) by DNA-TaqMan® and 75.1% (95% CI 69.8-80.4) by soluble egg antigen enzyme-linked immunosorbent assay (SEA-ELISA). A cross-comparison of diagnostic sensitivities, specificities, positive and negative predictive values was undertaken, inclusive of a latent class analysis (LCA) with a LCA-model estimate of prevalence by each school. The latter ranged from 9.6% to 100.0%, and prevalence by school for each diagnostic test followed a static ascending order or monotonic series of Kato-Katz, urine-CCA dipstick, DNA-TaqMan® and SEA-ELISA. We confirm that Kato-Katz remains a satisfactory diagnostic standalone in high-transmission settings but in low-transmission settings should be augmented or replaced by urine-CCA dipsticks. DNA-TaqMan® appears suitable in both endemic settings though is only implementable if resources permit. In low-transmission settings, SEA-ELISA remains the method of choice to evidence an absence infection. We discuss the pros and cons of each method concluding that future surveillance of intestinal schistosomiasis would benefit from a flexible, context-specific approach both in choice and application of each diagnostic method, rather than a single one-size fits all approach.

  1. The Motivation Analysis Test: an historical and contemporary evaluation.

    Science.gov (United States)

    Bernard, Larry C; Walsh, R Patricia; Mills, Michael

    2005-04-01

    This is an historical review and contemporary empirical evaluation of the Motivation Analysis Test (MAT), one of the first tests to take a psychometric approach to the assessment of motivation. Reviews were quite positive, but the test is now over 50 years old. Nevertheless, it employs innovations in measurement not widely used in objective measurement then or now: (1) subtests with different formats, (2) disguised items, (3) speeded administration procedures, and (4) ipsative format and scoring procedures. These issues are discussed and a contemporary sample (N = 360) obtained to evaluate the Motivation Analysis Test in light of its innovative characteristics.

  2. Reuse fo a Cold War Surveillance Drone to Flight Test a NASA Rocket Based Combined Cycle Engine

    Science.gov (United States)

    Brown, T. M.; Smith, Norm

    1999-01-01

    Plans for and early feasibility investigations into the modification of a Lockheed D21B drone to flight test the DRACO Rocket Based Combined Cycle (RBCC) engine are discussed. Modifications include the addition of oxidizer tanks, modern avionics systems, actuators, and a vehicle recovery system. Current study results indicate that the D21B is a suitable candidate for this application and will allow demonstrations of all DRACO engine operating modes at Mach numbers between 0.8 and 4.0. Higher Mach numbers may be achieved with more extensive modification. Possible project risks include low speed stability and control, and recovery techniques.

  3. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  4. Development of in-pile test and evaluation technology

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yung Hwan; Park, Jong Man; Joo, Kee Nam; Park, Duk Keun; Park, Se Jin; Oh, Jong Myung; Kim, Tae Ryong; Park Jin Suk; Lee, Jae Han [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-08-01

    To develop the in-pile test and evaluation technologies using KMRR, basic design of instrumented capsule and auxiliary system for material irradiation test and the related studies are performed. First, reactor and test hole characteristics are summarized, and conceptual design requirements of capsule to KMRR are reviewed. And fundamental principles and criteria for the instrumented capsule design are summarized. Basic design and analysis of instrumented capsule are performed, and design of capsule supporting system are also performed and structural integrity of the system is analyzed. Based on the prior studies, test mock-ups are designed and manufactured, and thermohydraulic and vibration tests are prepared. And, as in-pile test evaluation technologies, KMRR neutron dosimetry and mechanical tests related to material irradiation are investigated. 67 figs, 30 tabs, 41 refs. (Author).

  5. Personal Radiation Detector Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Chris A. Hodge, Ding Yuan, Raymond P. Keegan, Michael A. Krstich

    2007-01-01

    Following the success of the Anole test of portable detection system, the U.S. Department of Homeland Security (DHS) Domestic Nuclear Detection Office organized a test and evaluation campaign for personal radiation detectors (PRDs), also known as 'Pagers'. This test, 'Bobcat', was conducted from July 17 to August 8, 2006, at the Nevada Test Site. The Bobcat test was designed to evaluate the performance of PRDs under various operational scenarios, such as pedestrian surveying, mobile surveying, cargo container screening, and pedestrian chokepoint monitoring. Under these testing scenarios, many operational characteristics of the PRDs, such as gamma and neutron sensitivities, positive detection and false alarm rates, response delay times, minimum detectable activities, and source localization errors, were analyzed. This paper will present the design, execution, and methodologies used to test this equipment for the DHS

  6. Minnesota urban partnership agreement national evaluation : exogenous factors test plan.

    Science.gov (United States)

    2009-11-17

    This report presents the exogenous factors test plan for the national evaluation of the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reduc...

  7. Dredged Material Testing and Evaluation for Ocean Disposal

    Science.gov (United States)

    Evaluation and testing of dredged material proposed for ocean dumping is conducted to help protect human health and the marine environment. National guidance is provided by the Green Book. Regional Implementation Manuals are provided.

  8. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction

    OpenAIRE

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-01-01

    Introduction: Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. Subjects and methods: In prospective study, we evalua...

  9. Evaluating Past and Future USCG Use of Ohmsett Test Facility

    Science.gov (United States)

    2016-10-01

    of Pages 22 22. Price Evaluating Past and Future USCG Use of Ohmsett Test Facility iv UNCLAS//Public | | CG-926 RDC | M. Fitzpatrick, et al...Opportunity Skimming System WEC Wave energy converter Evaluating Past and Future USCG Use of Ohmsett Test Facility x UNCLAS//Public | | CG-926 RDC | M...Date Summary of Effort OCT-NOV 1993 Vessel of Opportunity Skimming System (VOSS) (5 Weeks) APR-JUN 1996 Spilled Oil Recovery System (SORS) (8 Weeks

  10. A Portable Environment Test System: A Field Assessment of Organotin Leachates--Test and Evaluation.

    Science.gov (United States)

    1987-11-01

    of organotin-based antifouling (AF) coatings, NOSC researchers used this facility to study the effects of tributyltin ( TBT ), the primary toxic ...Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) anti oling leachates in Sin Diego Bay over a 7-month period. Overall mean test...EXECUTIVE SUMMARY A Portable Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) antifouling leachates in San Diego Bay for 7

  11. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  12. Development and evaluation of a mixed long-chain lipopolysaccharide based ELISA for serological surveillance of infection with Actinobacillus pleuropneumoniae serotypes 2, 6 and 12 in pig herds

    DEFF Research Database (Denmark)

    Grøndahl-Hansen, Jan; Barfod, Kristen; Klausen, Joan

    2003-01-01

    The objective was to develop an enzyme-linked immunosorbent assay (ELISA) for simultaneous detection of antibodies against Actinobacillus pleuropneumoniae (Ap) serotypes 2, 6 and 12. The assay was designated MIX-ELISA. Lipopolysaccharide (LPS) from Ap serotypes 2, 6 and 12 was purified using hot...... of the assay indicate that screening of herds for Ap infection can be performed using this ELISA. Efficient serological surveillance can be achieved by using such mixed antigen ELISAs coated with size-selected LPS-antigens from the most prevalent serotypes....... phenol-water extraction followed by fractionation by size-exclusion chromatography. A mixture of fractions containing molecules with molecular weight above 50 kDa from all three serotypes was used as antigen. The MIX-ELISA was evaluated with sera from pigs experimentally infected with the serotypes 1, 2...

  13. Improvement of test methodology for evaluating diesel fuel stability

    Energy Technology Data Exchange (ETDEWEB)

    Gutman, M.; Tartakovsky, L.; Kirzhner, Y.; Zvirin, Y. [Internal Combustion Engines Lab., Haifa (Israel); Luria, D. [Fuel Authority, Tel Aviv (Israel); Weiss, A.; Shuftan, M. [Israel Defence Forces, Tel Aviv (Israel)

    1995-05-01

    The storage stability of diesel fuel has been extensively investigated for many years under laboratory conditions. Although continuous efforts have been made to improve testing techniques, there does not yet exist a generally accepted correlation between laboratory methods (such as chemical analysis of the fuel) and actual diesel engine tests. A testing method was developed by the Technion Internal Combustion Engines Laboratory (TICEL), in order to address this problem. The test procedure was designed to simulate diesel engine operation under field conditions. It is based on running a laboratory-modified single cylinder diesel engine for 50 h under cycling operating conditions. The overall rating of each test is based on individual evaluation of the deposits and residue formation in the fuel filter, nozzle body and needle, piston head, piston rings, exhaust valve, and combustion chamber (six parameters). Two methods for analyzing the test results were used: objective, based on measured data, and subjective, based on visual evaluation results of these deposits by a group of experts. Only the residual level in the fuel filter was evaluated quantitatively by measured results. In order to achieve higher accuracy of the method, the test procedure was improved by introducing the measured results of nozzle fouling as an additional objective evaluating (seventh) parameter. This factor is evaluated on the basis of the change in the air flow rate through the nozzle before and after the complete engine test. Other improvements in the method include the use of the nozzle assembly photograph in the test evaluation, and representation of all seven parameters on a continuous scale instead of the discrete scale used anteriorly, in order to achieve higher accuracy. This paper also contains the results obtained by application of this improved fuel stability test for a diesel fuel stored for a five-year period.

  14. Visual interface for the automation of the instrumented pendulum of Charpy tests used in the surveillance program of reactors vessel of nuclear power plants

    International Nuclear Information System (INIS)

    Rojas S, A.S.; Sainz M, E.; Ruiz E, J.A.

    2004-01-01

    Inside the Programs of Surveillance of the nuclear power stations periodic information is required on the state that keep the materials with those that builds the vessel of the reactor. This information is obtained through some samples or test tubes that are introduced inside the core of the reactor and it is observed if its physical characteristics remain after having been subjected to the radiation changes and temperature. The rehearsal with the instrumented Charpy pendulum offers information on the behavior of fracture dynamics of a material. In the National Institute of Nuclear Research (ININ) it has an instrumented Charpy pendulum. The operation of this instrument is manual, having inconveniences to carry out rehearsals with radioactive material, handling of high and low temperatures, to fulfill the normative ones for the realization of the rehearsals, etc. In this work the development of a computational program is presented (virtual instrument), for the automation of the instrumented pendulum. The system has modules like: Card of data acquisition, signal processing, positioning system, tempered system, pneumatic system, compute programs like it is the visual interface for the operation of the instrumented Charpy pendulum and the acquisition of impact signals. This system shows that given the characteristics of the nuclear industry with radioactive environments, the virtual instrumentation and the automation of processes can contribute to diminish the risks to the personnel occupationally exposed. (Author)

  15. Location-based HIV behavioural surveillance among MSM in Auckland, New Zealand 2002-2011: condom use stable and more HIV testing.

    Science.gov (United States)

    Saxton, Peter J W; Dickson, Nigel P; Hughes, Anthony J

    2014-03-01

    Over the last decade, annual HIV diagnoses among men who have sex with men (MSM) in New Zealand increased, then stabilised in 2006 and have not increased further. The aim was to examine trends in behaviours in order to better understand this pattern and inform community-based prevention. From 2002 to 2011, we conducted five repeat cross-sectional behavioural surveillance surveys among MSM at community locations in Auckland (fair day, gay bars, sex-on-site venues; n=6091). Participation was anonymous and self-completed. Recruitment methods were consistent at each round. Overall, the samples became more ethnically diverse and less gay community attached over time. Condom use during anal intercourse was stable across three partnering contexts (casual, current regular fuckbuddy, current regular boyfriend), with a drop among casual contacts in 2011 only. In the 6 months prior to surveys, there was a gradual decline over time in the proportion reporting >20 male partners, an increase in acquiring partners from the internet and increases in engagement in anal intercourse in some partnering contexts. HIV testing in the 12 months prior to surveys rose from 35.1% in 2002 to 50.4% in 2011, mostly from 2008. This first indepth examination of trends in HIV-related behaviours among five consecutive large and diverse samples of MSM in New Zealand does not suggest condom use is declining. However, subtle changes in sexual networks and partnering may be altering the epidemic determinants in this population and increasing exposure.

  16. Comparative study of heuristic evaluation and usability testing methods.

    Science.gov (United States)

    Thyvalikakath, Thankam Paul; Monaco, Valerie; Thambuganipalle, Himabindu; Schleyer, Titus

    2009-01-01

    Usability methods, such as heuristic evaluation, cognitive walk-throughs and user testing, are increasingly used to evaluate and improve the design of clinical software applications. There is still some uncertainty, however, as to how those methods can be used to support the development process and evaluation in the most meaningful manner. In this study, we compared the results of a heuristic evaluation with those of formal user tests in order to determine which usability problems were detected by both methods. We conducted heuristic evaluation and usability testing on four major commercial dental computer-based patient records (CPRs), which together cover 80% of the market for chairside computer systems among general dentists. Both methods yielded strong evidence that the dental CPRs have significant usability problems. An average of 50% of empirically-determined usability problems were identified by the preceding heuristic evaluation. Some statements of heuristic violations were specific enough to precisely identify the actual usability problem that study participants encountered. Other violations were less specific, but still manifested themselves in usability problems and poor task outcomes. In this study, heuristic evaluation identified a significant portion of problems found during usability testing. While we make no assumptions about the generalizability of the results to other domains and software systems, heuristic evaluation may, under certain circumstances, be a useful tool to determine design problems early in the development cycle.

  17. Evaluation of Surface Infiltration Testing Procedures in Permeable Pavement Systems

    Science.gov (United States)

    The ASTM method (ASTM C1701) for measuring infiltration rate of in-place pervious concrete provides limited guidance on how to select testing locations, so research is needed to evaluate how testing sites should be selected and how results should be interpreted to assess surface ...

  18. Evaluation of fuel rods behavior - under irradiation test

    International Nuclear Information System (INIS)

    Lameiras, F.S.; Terra, J.L.; Pinto, L.C.M.; Dias, M.S.; Pinheiro, R.B.

    1981-04-01

    By the accompanying of the irradiation of instrumented test fuel rods simulating the operational conditions in reactors, plus the results of post - irradiation exams, tests, evaluation and calibration of analitic modelling of such fuel rods is done. (E.G.) [pt

  19. GSFC Supplier Surveillance

    Science.gov (United States)

    Kelly, Michael P.

    2011-01-01

    Topics covered include: Develop Program/Project Quality Assurance Surveillance Plans The work activities performed by the developer and/or his suppliers are subject to evaluation and audit by government-designated representatives. CSO supports project by selecting on-site supplier representative s by one of several methods: (1) a Defense Contract Management Agency (DCMA) person via a Letter Of Delegation (LOD), (2) an independent assurance contractor (IAC) via a contract Audits, Assessments, and Assurance (A3) Contract Code 300 Mission Assurance Support Contract (MASC)

  20. 2018 NDIA 33rd Annual National Test and Evaluation Conference

    Science.gov (United States)

    2018-05-17

    funded under the Unmanned & Autonomous System Test (UAST) program to develop the “ Safe Testing of Autonomous Systems in Complex Environments ...Evaluators • Enables early verification that systems work in a Joint Environment • Test whether systems work well together • Supports all aspects of...to the Fisher House Foundation. HARASSMENT STATEMENT NDIA is committed to providing a professional environment free from physical, psychological and

  1. Ideology, Critique and Surveillance

    Directory of Open Access Journals (Sweden)

    Heidi Herzogenrath-Amelung

    2013-11-01

    Full Text Available The 2013 revelations concerning global surveillance programmes demonstrate in unprecedented clarity the need for Critical Theory of information and communication technologies (ICTs to address the mechanisms and implications of increasingly global, ubiquitous surveillance. This is all the more urgent because of the dominance of the “surveillance ideology” (the promise of security through surveillance that supports the political economy of surveillance. This paper asks which theoretical arguments and concepts can be useful for philosophically grounding a critique of this surveillance ideology. It begins by examining how the surveillance ideology works through language and introduces the concept of the ‘ideological packaging’ of ICTs to show how rhetoric surrounding the implementation of surveillance technologies reinforces the surveillance ideology. It then raises the problem of how ideology-critique can work if it relies on language itself and argues that Martin Heidegger’s philosophy can make a useful contribution to existing critical approaches to language.

  2. Pre-test evaluation of LLTR Series II Test A-6

    International Nuclear Information System (INIS)

    Knittle, D.

    1980-11-01

    Purpose of this report is to present pre-test predictions of pressure histories for the A6 test to be conducted in the Large Leak Test Facility (LLTF) at the Energy Technology Engineering Center. A6 is part of a test program being conducted to evaluate the effects of leaks produced by a double-ended guillotine rupture of a single tube. A6 will provide data on the CRBR prototypical double rupture disc performance

  3. Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction.

    Science.gov (United States)

    Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko

    2015-02-01

    Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student's T test was used. There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction.

  4. Evaluating PET-CT in routine surveillance and follow-up after treatment for cervical cancer: a cost-effectiveness analysis.

    Science.gov (United States)

    Auguste, P; Barton, P; Meads, C; Davenport, C; Małysiak, S; Kowalska, M; Zapalska, A; Guest, P; Martin-Hirsch, P; Borowiack, E; Khan, K; Sundar, S; Roberts, T

    2014-03-01

    To undertake a cost-effectiveness analysis that compares positron emission tomography - computed tomography (PET-CT) imaging plus standard practice with standard practice alone in the diagnosis of recurrent or persistent cervical cancer during routine surveillance and follow-up of women who have previously been diagnosed and treated. Model-based economic evaluation using data from a systematic review, supplemented with data from other sources, and taking a UK National Health Service (NHS) perspective. Secondary Care in England. Women at least 3 months after the completion of treatment, with either recurrent or persistent cervical cancer. A state transition (Markov) model was developed using TreeAge Pro 2011. The structure of the model was informed by the reviews of the trials and clinical input. In the model, two diagnostic strategies were examined. A one-way sensitivity analysis, probabilistic sensitivity analysis, and a value of information analysis were also carried out. Cost-effectiveness based on incremental cost per quality-adjusted life year (QALY). Adding PET-CT to the current treatment strategy of clinical examination and scanning [magnetic resonance imaging (MRI) and/or CT scan] during the routine surveillance and follow-up of women with recurrent or persistent cervical cancer is significantly more costly, with only a minimal increase in effectiveness. The incremental cost-effectiveness ratio (ICER) for the strategy of PET-CT as an adjunct to the standard treatment strategy that included clinical examination, MRI, and/or CT scan, compared with the usual treatment alone, was over £1 million per QALY. The results of the current analysis suggest that use of PET-CT in the diagnosis of recurrent or persistent cervical cancer is not cost-effective. Current guidelines recommending imaging using PET-CT as a diagnostic or surveillance tool need to be reconsidered in light of these results. This study did not specifically investigate the use of PET-CT in women

  5. Evaluating genomic tests from bench to bedside: a practical framework

    Directory of Open Access Journals (Sweden)

    Lin Jennifer S

    2012-10-01

    Full Text Available Abstract The development of genomic tests is one of the most significant technological advances in medical testing in recent decades. As these tests become increasingly available, so does the need for a pragmatic framework to evaluate the evidence base and evidence gaps in order to facilitate informed decision-making. In this article we describe such a framework that can provide a common language and benchmarks for different stakeholders of genomic testing. Each stakeholder can use this framework to specify their respective thresholds for decision-making, depending on their perspective and particular needs. This framework is applicable across a broad range of test applications and can be helpful in the application and communication of a regulatory science for genomic testing. Our framework builds upon existing work and incorporates principles familiar to researchers involved in medical testing (both diagnostic and prognostic generally, as well as those involved in genomic testing. This framework is organized around six phases in the development of genomic tests beginning with marker identification and ending with population impact, and highlights the important knowledge gaps that need to be filled in establishing the clinical relevance of a test. Our framework focuses on the clinical appropriateness of the four main dimensions of test research questions (population/setting, intervention/index test, comparators/reference test, and outcomes rather than prescribing a hierarchy of study designs that should be used to address each phase.

  6. Post-tensioning system surveillance program

    International Nuclear Information System (INIS)

    Drew, G.E.

    1979-01-01

    Nuclear power plant containment structure post-tensioning system tendon surveillance program is described in detail. Data collected over three yearly post-tensioning system Surveillance Programs is presented and evaluated to correlate anticipated stress losses with actual losses. In addition corrosion protected system performance is analyzed

  7. Evaluation tests of industrial vacuum bearings for space use

    Science.gov (United States)

    Obara, S.; Sasaki, A.; Haraguchi, M.; Imagawa, K.; Nishimura, M.; Kawashima, N.

    2001-09-01

    Tribological performance of industrial vacuum bearings was experimentally evaluated for space use. The bearings selected for investigation were an 8 mm bore-sized deep-groove ball bearing lubricated with a sputtered MoS2 film and that lubricated with an ion-plated Ag film, commercially delivered from three Japanese domestic bearing-manufacturers. Based on survey results of tribological requirements for the existing satellite mechanisms, four types of bearing tests were defined and conducted: a vacuum test at room temperature, an atmosphere-resistant test, a thermal vacuum test and a vibration test. In addition to these tests, variation in tribological performance of the industrial bearings was also investigated. The results of more than eighty tests demonstrated that the industrial vacuum bearings had sufficient lubrication lives with low frictional torque and their data were reasonably repeatable, indicating very good potentiality for space use.

  8. PR.Latent-class methods to evaluate diagnostics tests for echinococcus infections in dogs.

    NARCIS (Netherlands)

    Hartnack, S.; Budke, C.M.; Craig, P.S.; Jiamin, Q.; Boufana, B.; Campos Ponce, M.; Torgerson, P.R.

    2013-01-01

    Background: The diagnosis of canine echinococcosis can be a challenge in surveillance studies because there is no perfect gold standard that can be used routinely. However, unknown test specificities and sensitivities can be overcome using latent-class analysis with appropriate data. Methodology: We

  9. Automation and Evaluation of the SOWH Test with SOWHAT.

    Science.gov (United States)

    Church, Samuel H; Ryan, Joseph F; Dunn, Casey W

    2015-11-01

    The Swofford-Olsen-Waddell-Hillis (SOWH) test evaluates statistical support for incongruent phylogenetic topologies. It is commonly applied to determine if the maximum likelihood tree in a phylogenetic analysis is significantly different than an alternative hypothesis. The SOWH test compares the observed difference in log-likelihood between two topologies to a null distribution of differences in log-likelihood generated by parametric resampling. The test is a well-established phylogenetic method for topology testing, but it is sensitive to model misspecification, it is computationally burdensome to perform, and its implementation requires the investigator to make several decisions that each have the potential to affect the outcome of the test. We analyzed the effects of multiple factors using seven data sets to which the SOWH test was previously applied. These factors include a number of sample replicates, likelihood software, the introduction of gaps to simulated data, the use of distinct models of evolution for data simulation and likelihood inference, and a suggested test correction wherein an unresolved "zero-constrained" tree is used to simulate sequence data. To facilitate these analyses and future applications of the SOWH test, we wrote SOWHAT, a program that automates the SOWH test. We find that inadequate bootstrap sampling can change the outcome of the SOWH test. The results also show that using a zero-constrained tree for data simulation can result in a wider null distribution and higher p-values, but does not change the outcome of the SOWH test for most of the data sets tested here. These results will help others implement and evaluate the SOWH test and allow us to provide recommendations for future applications of the SOWH test. SOWHAT is available for download from https://github.com/josephryan/SOWHAT. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists.

  10. Multicenter, noninterventional, post-marketing surveillance study to evaluate dosing of recombinant human follicle-stimulating hormone using the redesigned follitropin alfa pen in women undergoing ovulation induction

    Science.gov (United States)

    Nawroth, Frank; Tandler-Schneider, Andreas; Bilger, Wilma

    2015-01-01

    This prospective, noninterventional, post-marketing surveillance study evaluated doses of recombinant human follicle-stimulating hormone (r-hFSH) using the redesigned follitropin alfa pen in women who were anovulatory or oligomenorrheic and undergoing ovulation induction (OI) alone or OI with intrauterine insemination. The primary endpoint was the proportion of patients who achieved monofollicular or bifollicular development (defined as one or two follicles ≥15 mm). Secondary endpoints included characteristics of ovulation stimulation treatment, such as mean total and mean daily r-hFSH doses. Data were analyzed for 3,193 patients from 30 German fertility centers. The proportion of patients with monofollicular or bifollicular development was 71.1% (n=2,270 of a total of 3,193 patients; intent-to-treat population). The mean±standard deviation total and daily doses of r-hFSH were 696.9±542.5 IU and 61.7±29.4 IU, respectively. The three doses prescribed most frequently were: 37.5 IU (n=703 from N=3,189; 22.0%), 50.0 IU (n=1,056 from N=3,189; 33.1%), and 75.0 IU (n=738 from N=3,189; 23.1%) on the first day of stimulation; and 37.5 IU (n=465 from N=3,189; 14.6%), 50.0 IU (n=922 from N=3,189; 28.9%), and 75.0 IU (n=895 from N=3,189; 28.1%) on the last day of stimulation. This noninterventional, post-marketing surveillance study found that monofollicular or bifollicular development was achieved in 71% of patients studied and the small dose increment (12.5 IU) of the redesigned follitropin alfa pen allowed individualized treatment of women undergoing OI. PMID:25926755

  11. Novel speed test for evaluation of badminton specific movements

    DEFF Research Database (Denmark)

    Madsen, Christian Møller; Karlsen, Anders; Nybo, Lars

    2015-01-01

    In this study we developed a novel badminton speed test (BST). The test was designed to mimic match play. The test starts in the center of the court and consists of five maximal actions to sensors located in each of the four corners of the court. The 20 actions are performed in randomized order...... as dictated by computer screen shots displayed one second following completion of the previous action. We assessed day-to-day variation in elite players and specificity of the test was evaluated by comparing 30 meter sprint performance and time to complete the BST in 20 elite, 21 skilled players and 20 age...

  12. State-of-the-art tests for evaluating coatings

    International Nuclear Information System (INIS)

    Wallace, B.A.; Thompson, J.C.

    1984-01-01

    This article is not intended to give a complete test program for evaluating coatings, but to supplement the standard referenced tests. Particular tests described emphasize how coating performance is affected by the thermal expansion forces that attempt to prevent anchoring of pipe lines; effects of the wet/dry cycles on buried lines; effect on cathodic disbondment at elevated temperatures, voltages, and pressures; ability to withstand a hot marine mastic pour; temperature cycling, shear and creep tests on concrete-coated pipe, and effects of stinger stress loading

  13. Impact assessment of malaria vector control using routine surveillance data in Zambia: implications for monitoring and evaluation

    Directory of Open Access Journals (Sweden)

    Chanda Emmanuel

    2012-12-01

    Full Text Available Abstract Background Malaria vector control using long-lasting insecticidal nets (LLINs and indoor residual spraying (IRS, with pyrethroids and DDT, to reduce malaria transmission has been expansively implemented in Zambia. The impact of these interventions on malaria morbidity and mortality has not previously been formally assessed at the population level in Zambia. Methods The impact of IRS (15 urban districts and LLINs (15 rural districts implementation on severe malaria cases, deaths and case fatality rates in children below the age of five years were compared. Zambian national Health Management Information System data from 2007 to 2008 were retrospectively analysed to assess the epidemiological impact of the two interventions using odds ratios to compare the pre-scaling up year 2007 with the scaling-up year 2008. Results Overall there were marked reductions in morbidity and mortality, with cases, deaths and case fatality rates (CFR of severe malaria decreasing by 31%, 63% and 62%, respectively between 2007 and 2008. In urban districts with IRS introduction there was a significant reduction in mortality (Odds Ratio [OR] = 0.37, 95% CI = 0.31-0.43, P = 0.015, while the reduction in mortality in rural districts with LLINs implementation was not significant (OR = 0.83, 95% CI = 0.67-1.04, P = 0.666. A similar pattern was observed for case fatality rates with a significant reduction in urban districts implementing IRS (OR = 0.34, 95% CI = 0.33-0.36, P = 0.005, but not in rural districts implementing LLINs (OR = 0.96, 95% CI = 0.91-1.00, P = 0.913. No substantial difference was detected in overall reduction of malaria cases between districts implementing IRS and LLINs (P = 0.933. Conclusion Routine surveillance data proved valuable for determining the temporal effects of malaria control with two strategies, IRS and LLINs on severe malaria disease in different types of Zambian districts. However, this analysis did not take into account the effect

  14. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  15. Evaluation of cold testing for Tokai Vitrification Facility

    International Nuclear Information System (INIS)

    Yoshioka, Masahiro; Inada, Eiichi

    1994-01-01

    The cold testing of the Tokai Vitrification Facility (TVF) was completed at the end of March, 1994 through the tests of nearly two years since May in 1992. The cold testing was carried out in order to evaluate the process equipment, product quality control, remote maintenance capability. The test results shown that TVF has enough performance with safety to treat the liquid waste in each process, and to control the product quality. For the remote maintenance of process equipment in the vitrification cell, the remote maintenance capability was confirmed for all remote equipment in the cell. The improvements were taken for some equipment with problem from the point of the operability and maintenance. It was confirmed by these test results that the TVF can go forward to the hot test operation using actual waste. (author)

  16. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Science.gov (United States)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  17. Development of Testing Methodologies to Evaluate Postflight Locomotor Performance

    Science.gov (United States)

    Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Richards, J. T.; Miller, C. A.; Brady, R.; Warren, L. E.; Bloomberg, J. J.

    2006-01-01

    Crewmembers experience locomotor and postural instabilities during ambulation on Earth following their return from space flight. Gait training programs designed to facilitate recovery of locomotor function following a transition to a gravitational environment need to be accompanied by relevant assessment methodologies to evaluate their efficacy. The goal of this paper is to demonstrate the operational validity of two tests of locomotor function that were used to evaluate performance after long duration space flight missions on the International Space Station (ISS).

  18. Evaluation of the radiological situation of the French environment in 2007. Synthesis of the I.R.S.N. surveillance networks

    International Nuclear Information System (INIS)

    2008-01-01

    After a reminder of the objectives and the organisation of the radiological surveillance, the radiological events detected in 2007 are given: high tritium activity in a water sampling (Saclay), detection of alpha emitters in aerosols sampling (Pierrelatte), detection of cobalt 60 in an aerosol sampling (Somanu Areva), increase of a global beta activity in aerosols (north-east and center of France), detection of uranium in water (Pithiviers). We find then the results of the surveillance of fuel cycle sites, the results of the surveillance of the research centers and naval base, the results of the surveillance of radioactive release of nuclear medicine services, the results of the general surveillance of the territory (and the different Internet sites that give these data). This report ends with notions about radioactivity and ionizing radiations as well as radiation protection basic knowledge. (N.C.)

  19. Test and evaluation of radioactively contaminated transducers and transmitters

    International Nuclear Information System (INIS)

    Strahm, R.C.

    1983-01-01

    People in the nuclear industries face some unique problems when handling, testing, or examining transducers and transmitters that have been radioactively contaminated. Although many people and organizations, including EG and G Idaho, have performed such work for many years, there are no set, structured approaches or procedures. This paper discusses a disciplined laboratory approach to contaminated transducer testing and evaluation, utilizing equipment and facilities developed specifically for this type of work

  20. Evaluation of pavement joint sealants :a new testing technique

    OpenAIRE

    Abo-Qudais, Saad A.

    1992-01-01

    A new method to evaluate the performance of sealants, used in rigid pavement joints, was developed. A special fixture was designed to transfer cyclic in-line deflection, applied by a testing machine, to cyclic normal and shear deflections on a sealant sandwiched between two-2 x 2 x 2 in. portland cement mortar cubes. The normal and shear deflections were applied simultaneously at a specific ratio controlled by the developed fixture. The new testing method simulates field ...

  1. Evaluation test on stability of high temperature strain gage

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Toshimi (Kyowa Electronic Instruments Co. Ltd., Tokyo (Japan)); Ito, Haruhiko; Tanaka, Isao; Komori, Yoshihiro

    1983-08-01

    This report deals with the results on a stability test of high temperature strain gage which is utilized for development of the Stethoscope for OGL - 1 Components in Elevated Temperature Services (ab. SOCETS). The test has proved that the weldable strain gage (KHC - 20 - G5) exhibits excellent stability at 500/sup 0/C during 3000 to 4000 hours service and can be applied sufficiently to evaluate integrity of OGL - 1 high temperature pipings and others.

  2. Evaluation test on stability of high temperature strain gage

    International Nuclear Information System (INIS)

    Sato, Toshimi; Ito, Haruhiko; Tanaka, Isao; Komori, Yoshihiro.

    1983-01-01

    This report deals with the results on a stability test of high temperature strain gage which is utilized for development of the Stethoscope for OGL - 1 Components in Elevated Temperature Services (ab. SOCETS). The test has proved that the weldable strain gage (KHC - 20 - G5) exhibits excellent stability at 500 0 C during 3000 to 4000 hours service and can be applied sufficiently to evaluate integrity of OGL - 1 high temperature pipings and others. (author)

  3. Shuttle orbiter Ku-band radar/communications system design evaluation. Deliverable test equipment evaluation

    Science.gov (United States)

    Maronde, R. G.

    1980-07-01

    The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.

  4. Nuclear reactor pressure vessel integrity insurance by crack arrestability evaluation using load from CVN tests

    International Nuclear Information System (INIS)

    Fabry, A.

    1997-01-01

    The present work is undertaken in the framework of nuclear reactor pressure vessel (RPV) surveillance and aims at revisiting the crack arrest approach to structural integrity insurance. This approach, performed under normal plant operation conditions, can also offer an attractive alternative to the crack initiation philosophy promoted for accidental analysis. To this end, an accidental conservative, cost effective and robust methodology is forwarded and demonstrated: it makes use of the crack arrest information contained in the instrumented Charpy V-notch impact test and/or in the shear fracture appearance of broken samples. Particular attention is paid to the appraisal of uncertainties and the related safety margin. The resulting capability is placed in perspective with the state-of-the-art crack initiation methodology based on the slow bend testing of recracked specimens, presently under standardization world-wide. The investigation leads to highlight three conceptual weaknesses of current enfgineering and regulatory practices. Improved crack arrestability evaluation emerges as an optimal approach to insure safe PWR operation up to design end-of-life and beyond

  5. Nuclear reactor pressure vessel integrity insurance by crack arrestability evaluation using load from CVN tests

    Energy Technology Data Exchange (ETDEWEB)

    Fabry, A.

    1997-10-15

    The present work is undertaken in the framework of nuclear reactor pressure vessel (RPV) surveillance and aims at revisiting the crack arrest approach to structural integrity insurance. This approach, performed under normal plant operation conditions, can also offer an attractive alternative to the crack initiation philosophy promoted for accidental analysis. To this end, an accidental conservative, cost effective and robust methodology is forwarded and demonstrated: it makes use of the crack arrest information contained in the instrumented Charpy V-notch impact test and/or in the shear fracture appearance of broken samples. Particular attention is paid to the appraisal of uncertainties and the related safety margin. The resulting capability is placed in perspective with the state-of-the-art crack initiation methodology based on the slow bend testing of recracked specimens, presently under standardization world-wide. The investigation leads to highlight three conceptual weaknesses of current enfgineering and regulatory practices. Improved crack arrestability evaluation emerges as an optimal approach to insure safe PWR operation up to design end-of-life and beyond.

  6. Framework for a National Testing and Evaluation Program ...

    Science.gov (United States)

    Abstract:The National STEPP Program seeks to improve water quality by accelerating the effective implementation and adoption of innovative stormwater management technologies. Itwill attempt to accomplish this by establishing practices through highly reliable, and cost-effective Stormwater control measures (SCM) testing, evaluation, and verification services. The program will aim to remove barriers to innovation, minimize duplicative performance evaluation needs, increase confidence that regulatory requirements are met by creating consistency among testing and evaluation protocols, and establishing equity between public domain and proprietary SCM evaluation approaches.The Environmental Technology Verification Program, established by the U.S. Environmental Protection Agency (EPA) 18 years ago, was the only national program of its kindin the stormwater sector, but is now defunct, leaving a national leadership void. The STEPP initiative was triggered in part by regulatory demands in the government and private sectors to fill this vacuum. A concerted focus and study of this matter led to the release of a Water Environment Federation (WEF) white paper entitled “Investigation into the Feasibility of a National Testing and Evaluation Program for Stormwater Products and Practices” in February 2014. During this second phase of the STEPP initiative, and with EPA support, five analogous technology evaluation programs related to both stormwater and non-stormwater were an

  7. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  8. Health surveillance of radiological work

    International Nuclear Information System (INIS)

    Pauw, H.; Vliet, J.V.D.; Zuidema, H.

    1988-01-01

    Shielding x-ray devices and issuing film badges to radiological workers in 1936 can be considered the start of radiological protection in the Philips enterprises in the Netherlands. Shielding and equipment were constantly improved based upon the dosimetry results of the filmbadges. The problem of radioactive waste led to the foundation of a central Philips committee for radiological protection in 1956, which in 1960 also issued an internal license system in order to regulate the proper precautions to be taken : workplace design and layout, technological provisions and working procedures. An evaluation of all radiological work in 1971 learnt that a stricter health surveillance program was needed to follow up the precautions issued by the license. On one hand a health surveillance program was established and on the other hand all types of radiological work were classified. In this way an obligatory and optimal health surveillance program was issued for each type of radiological work

  9. Developing a Test Collection for the Evaluation of Integrated Search

    DEFF Research Database (Denmark)

    Lykke, Marianne; Larsen, Birger; Lund, Haakon

    2010-01-01

    he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection c...... assessments. The test collection may be used for systems- as well as user-oriented evaluation.......he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection...... constructed for this purpose. The test collection consists of approx. 18,000 monographic records, 160,000 papers and journal articles in PDF and 275,000 abstracts with a varied set of metadata and vocabularies from the physics domain, 65 topics based on real work tasks and corresponding graded relevance...

  10. Evaluating rodent motor functions: Which tests to choose?

    Science.gov (United States)

    Schönfeld, Lisa-Maria; Dooley, Dearbhaile; Jahanshahi, Ali; Temel, Yasin; Hendrix, Sven

    2017-12-01

    Damage to the motor cortex induced by stroke or traumatic brain injury (TBI) can result in chronic motor deficits. For the development and improvement of therapies, animal models which possess symptoms comparable to the clinical population are used. However, the use of experimental animals raises valid ethical and methodological concerns. To decrease discomfort by experimental procedures and to increase the quality of results, non-invasive and sensitive rodent motor tests are needed. A broad variety of rodent motor tests are available to determine deficits after stroke or TBI. The current review describes and evaluates motor tests that fall into three categories: Tests to evaluate fine motor skills and grip strength, tests for gait and inter-limb coordination and neurological deficit scores. In this review, we share our thoughts on standardized data presentation to increase data comparability between studies. We also critically evaluate current methods and provide recommendations for choosing the best behavioral test for a new research line. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. The particle swarm optimization algorithm applied to nuclear systems surveillance test planning; Otimizacao aplicada ao planejamento de politicas de testes em sistemas nucleares por enxame de particulas

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Newton Norat

    2006-12-15

    This work shows a new approach to solve availability maximization problems in electromechanical systems, under periodic preventive scheduled tests. This approach uses a new Optimization tool called PSO developed by Kennedy and Eberhart (2001), Particle Swarm Optimization, integrated with probabilistic safety analysis model. Two maintenance optimization problems are solved by the proposed technique, the first one is a hypothetical electromechanical configuration and the second one is a real case from a nuclear power plant (Emergency Diesel Generators). For both problem PSO is compared to a genetic algorithm (GA). In the experiments made, PSO was able to obtain results comparable or even slightly better than those obtained b GA. Therefore, the PSO algorithm is simpler and its convergence is faster, indicating that PSO is a good alternative for solving such kind of problems. (author)

  12. Evaluation of three oil spill laboratory dispersant effectiveness tests

    International Nuclear Information System (INIS)

    Sullivan, D.; Farlow, J.; Sahatjian, K.A.

    1993-01-01

    Chemical dispersants can be used to reduce the interfacial tension of floating oil slicks so that the oils disperse more rapidly into the water column and thus pose less of a threat to shorelines, birds, and marine mammals. The laboratory test currently specified in federal regulations to measure dispersant effectiveness is not especially easy or inexpensive, and generates a rather large quantity of oily waste water. This paper describes the results of an effort by the EPA to identify a more suitable laboratory dispersant effectiveness test. EPA evaluated three laboratory methods: the Revised Standard Dispersant Effectiveness Test currently used (and required by regulation) in the United States, the swirling flask test (developed by Environment Canada), and the IFP-dilution test (used in france and other European countries). Six test oils and three dispersants were evaluated; dispersants were applied to the oil at an average 1:10 ratio (dispersant to oil) for each of the three laboratory methods. Screening efforts were used to focus on the most appropriate oil/dispersant combination for detailed study. A screening criterion was established that required a combination that gave at least 20% effectiveness results. The selected combination turned out to be Prudhoe Bay crude oil and the dispersant Corexit 9527. This combination was also most likely to be encountered in US coastal waters. The EPA evaluation concluded that the three tests gave similar precision results, but that the swirling flask test was fastest, cheapest, simplest, and required least operator skill. Further, EPA is considering conducting the dispersant effectiveness test itself, rather than having data submitted by a dispersant manufacturer, and establishing an acceptability criterion (45% efficiency) which would have to be met before a dispersant could be placed on the Product Schedule of the National Contingency Plan (NCP)

  13. Evaluation of Gamma Interferon and Antibody Tuberculosis Tests in Alpacas

    Science.gov (United States)

    Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin

    2012-01-01

    We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a “test package,” although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations. PMID:22914362

  14. Evaluation of the Wishart test statistics for polarimetric SAR data

    DEFF Research Database (Denmark)

    Skriver, Henning; Nielsen, Allan Aasbjerg; Conradsen, Knut

    2003-01-01

    A test statistic for equality of two covariance matrices following the complex Wishart distribution has previously been used in new algorithms for change detection, edge detection and segmentation in polarimetric SAR images. Previously, the results for change detection and edge detection have been...... quantitatively evaluated. This paper deals with the evaluation of segmentation. A segmentation performance measure originally developed for single-channel SAR images has been extended to polarimetric SAR images, and used to evaluate segmentation for a merge-using-moment algorithm for polarimetric SAR data....

  15. Tamper-indicating devices and safeguards seals evaluation test report

    International Nuclear Information System (INIS)

    Horton, P.R.V.; Waddoups, I.G.

    1993-12-01

    Sandia National Laboratories was asked to evaluate the seals used as tamper-indicating devices (TIDs) at DOE facilities. Initially, a survey determined what seal manufacturers were being used and what similar seal types were available. Once the required specifications for TIDs were defined, a test plan measured the currently available seals against the requirements. Environmental and physical type tests stressed the seals under two broad categories: (1) handling durability and (2) tamper resistance. Results of the testing provide comparative ratings for the various seals, recommendations for using currently available seals, and a new tamper-indicating technology

  16. Crack arrest toughness of structural steels evaluated by compact test

    International Nuclear Information System (INIS)

    Nakano, Yoshifumi; Tanaka, Michihiro

    1982-01-01

    Crack arrest tests such as compact, ESSO and DCB tests were made on SA533B Cl. 1, HT80 and KD32 steels to evaluate the crack arrest toughness. The main results obtained are as follows: (1) The crack arrest toughness could be evaluated by K sub(Ia) which was obtained by the static analysis of compact test. (2) K sub(ID) determined by the dynamic analysis of compact test was greater than K sub(Ia), though K sub(ID) became close to K sub(Ia)/K sub(Q) became a unity where K sub(Q) is the stress intensity factor at the crack initiation. (3) No significant difference was observed between K sub(Ia) and K sub(ca) obtained by ESSO and DCB tests, though K sub(ca) obtained by DCB test tended to be smaller than K sub(Ia) at lower temperatures. (4) K sub(Ia) was smaller than K sub(Ic) in the transition temperature range, while it was greater than K sub(Id). In the temperature range where K sub(Ic), which was determined from J sub(Ic), decreased with temperature increase, however, it was smaller than K sub(Ia). (5) The fracture appearance transition temperature and the absorbed energy obtained by 2 mm V-notch Charpy test were appropriate parameters for representing the crack arrest toughness, while the NDT temperature was not. (author)

  17. Evaluation of ID-PaGIA syphilis antibody test.

    Science.gov (United States)

    Naaber, Paul; Makoid, Ene; Aus, Anneli; Loivukene, Krista; Poder, Airi

    2009-01-01

    Laboratory diagnosis of syphilis is usually accomplished by serology. There are currently a large number of different commercial treponemal tests available that vary in format, sensitivity and specificity. To evaluate the ID-PaGIA Syphilis Antibody Test as an alternative to other specific treponemal tests for primary screening or confirmation of diagnosis. Serum samples from healthy adults (n = 100) were used for detection of specificity of ID-PaGIA. To evaluate sensitivity of ID-PaGIA serum samples (n = 101) from patients with confirmed or suspected syphilis were tested for syphilis antibodies with FTA-Abs IgM, ID-PaGIA, ELISA IgM and TPHA tests. No false-positive results were found with ID-PaGIA. Sensitivity of various treponemal tests was the following: FTA-Abs IgM: 95.5%, ID-PaGIA and ELISA IgM: 94%, and TPHA 75%. The positive and negative predictive values of ID-PaGIA were 100 and 89.5%, respectively. Compared with other treponemal tests ID-PaGIA has excellent sensitivity and specificity.

  18. Efficient p-value evaluation for resampling-based tests

    KAUST Repository

    Yu, K.

    2011-01-05

    The resampling-based test, which often relies on permutation or bootstrap procedures, has been widely used for statistical hypothesis testing when the asymptotic distribution of the test statistic is unavailable or unreliable. It requires repeated calculations of the test statistic on a large number of simulated data sets for its significance level assessment, and thus it could become very computationally intensive. Here, we propose an efficient p-value evaluation procedure by adapting the stochastic approximation Markov chain Monte Carlo algorithm. The new procedure can be used easily for estimating the p-value for any resampling-based test. We show through numeric simulations that the proposed procedure can be 100-500 000 times as efficient (in term of computing time) as the standard resampling-based procedure when evaluating a test statistic with a small p-value (e.g. less than 10( - 6)). With its computational burden reduced by this proposed procedure, the versatile resampling-based test would become computationally feasible for a much wider range of applications. We demonstrate the application of the new method by applying it to a large-scale genetic association study of prostate cancer.

  19. Waste Handling Equipment Development Test and Evaluation Study

    International Nuclear Information System (INIS)

    R.L. Tome

    1998-01-01

    The purpose of this study is to identify candidate Monitored Geologic Repository (MGR) surface waste handling equipment for development testing. This study will also identify strategies for performing the development tests. Development testing shall be implemented to support detail design and reduce design risks. Development testing shall be conducted to confirm design concepts, evaluate alternative design concepts, show the availability of needed technology, and provide design documentation. The candidate equipment will be selected from MGR surface waste handling equipment that is the responsibility of the Management and Operating Contractor (M and O) Surface Design Department. The equipment identified in this study is based on Viability Assessment (VA) design. The ''Monitored Geologic Repository Test and Evaluation Plan'' (MGR T and EP), Reference 5.1, was used as a basis for this study. The MGR T and EP reflects the extent of test planning and analysis that can be conducted, given the current status of the MGR requirements and latest VA design information. The MGR T and EP supports the appropriate sections in the license application (LA) in accordance with 10 CFR 60.2 1(c)(14). The MGR T and EP describes the following test activities: site characterization to confirm, by test and analysis, the suitability of the Yucca Mountain site for housing a geologic repository; development testing to investigate and document design concepts to reduce risk; qualification testing to verify equipment compliance with design requirements, specifications, and regulatory requirements; system testing to validate compliance with MGR requirements, which include the receipt, handling, retrieval, and disposal of waste; periodic performance testing to verify preclosure requirements and to demonstrate safe and reliable MGR operation; and performance confirmation modeling, testing, and analysis to verify adherence to postclosure regulatory requirements. Development test activities can be

  20. Reliability demonstration of imaging surveillance systems

    International Nuclear Information System (INIS)

    Sheridan, T.F.; Henderson, J.T.; MacDiarmid, P.R.

    1979-01-01

    Security surveillance systems which employ closed circuit television are being deployed with increasing frequency for the protection of property and other valuable assets. A need exists to demonstrate the reliability of such systems before their installation to assure that the deployed systems will operate when needed with only the scheduled amount of maintenance and support costs. An approach to the reliability demonstration of imaging surveillance systems which employ closed circuit television is described. Failure definitions based on industry television standards and imaging alarm assessment criteria for surveillance systems are discussed. Test methods which allow 24 hour a day operation without the need for numerous test scenarios, test personnel and elaborate test facilities are presented. Existing reliability demonstration standards are shown to apply which obviate the need for elaborate statistical tests. The demonstration methods employed are shown to have applications in other types of imaging surveillance systems besides closed circuit television

  1. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    lifting and supporting weights) and have an important influence on blood pressure, it is essential to evaluate blood pressure response to iso- metric effort. This test can reveal high blood pressure that might otherwise not be detected. Only a few ...

  2. Evaluation of the separate effects tests (SET) validation matrix

    International Nuclear Information System (INIS)

    1996-11-01

    This work is the result of a one year extended mandate which has been given by the CSNI on the request of the PWG 2 and the Task Group on Thermal Hydraulic System Behaviour (TG THSB) in late 1994. The aim was to evaluate the SET validation matrix in order to define the real needs for further experimental work. The statistical evaluation tables of the SET matrix provide an overview of the data base including the parameter ranges covered for each phenomenon and selected parameters, and questions posed to obtain answers concerning the need for additional experimental data with regard to the objective of nuclear power plant safety. A global view of the data base is first presented focussing on areas lacking in data and on hot topics. A new systematic evaluation has been done based on the authors technical judgments and giving evaluation tables. In these tables, global and indicative information are included. Four main parameters have been chosen as the most important and relevant parameters: a state parameter given by the operating pressure of the tests, a flow parameter expressed as mass flux, mass flow rate or volumetric flow rate in the tests, a geometrical parameter provided through a typical dimension expressed by a diameter, an equivalent diameter (hydraulic or heated) or a cross sectional area of the test sections, and an energy or heat transfer parameter given as the fluid temperature, the heat flux or the heat transfer surface temperature of the tests

  3. Evaluating the Zebrafish Embryo Toxicity Test for Pesticide Hazard Screening

    Science.gov (United States)

    Given the numerous chemicals used in society, it is critical to develop tools for accurate and efficient evaluation of potential risks to human and ecological receptors. Fish embryo acute toxicity tests are 1 tool that has been shown to be highly predictive of standard, more reso...

  4. Evaluation and testing methodology for evolving entertainment systems

    NARCIS (Netherlands)

    Jurgelionis, A.; Bellotti, F.; IJsselsteijn, W.A.; Kort, de Y.A.W.; Bernhaupt, R.; Tscheligi, M.

    2007-01-01

    This paper presents a testing and evaluation methodology for evolving pervasive gaming and multimedia systems. We introduce the Games@Large system, a complex gaming and multimedia architecture comprised of a multitude of elements: heterogeneous end user devices, wireless and wired network

  5. Product evaluation of in situ vitrification engineering, Test 4

    International Nuclear Information System (INIS)

    Loehr, C.A.; Weidner, J.R.; Bates, S.O.

    1991-09-01

    This report is one of several that evaluates the In Situ Vitrification (ISV) Engineering-Scale Test 4 (ES-4). This document describes the chemical and physical composition, microstructure, and leaching characteristics of ES-4 product samples; these data provide insight into the expected performance of a vitrified product in an ISV buried waste application similar to that studied in ES-4

  6. Evaluating the Predictive Validity of Graduate Management Admission Test Scores

    Science.gov (United States)

    Sireci, Stephen G.; Talento-Miller, Eileen

    2006-01-01

    Admissions data and first-year grade point average (GPA) data from 11 graduate management schools were analyzed to evaluate the predictive validity of Graduate Management Admission Test[R] (GMAT[R]) scores and the extent to which predictive validity held across sex and race/ethnicity. The results indicated GMAT verbal and quantitative scores had…

  7. Evaluating the Instructional Sensitivity of Four States' Student Achievement Tests

    Science.gov (United States)

    Polikoff, Morgan S.

    2016-01-01

    As state tests of student achievement are used for an increasingly wide array of high- and low-stakes purposes, evaluating their instructional sensitivity is essential. This article uses data from the Bill and Melinda Gates Foundation's Measures of Effective Project to examine the instructional sensitivity of 4 states' mathematics and English…

  8. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  9. A Pilot Study to Increase the Efficiency of HIV Outreach Testing Through the Use of Timely and Geolocated HIV Viral Load Surveillance Data

    Science.gov (United States)

    Jennings, Jacky M.; Schumacher, Christina; Perin, Jamie; Myers, Tanya; Fields, Nathan; Greiner Safi, Amelia; Chaulk, Patrick

    2018-01-01

    Background Eliminating HIV transmission in a population necessitates identifying population reservoirs of HIV infection and subgroups most likely to transmit. HIV viral load is the single most important predictor of HIV transmission. The objective of this analysis was to evaluate whether a public health practice pilot project based on community viral load resulted in increases in the proportion of time spent testing in high viral load areas (process measure) and 3 outcome measures—the number and percent of overall HIV diagnoses, new diagnoses, and high viral load positives—in one mid-Atlantic US city with a severe HIV epidemic. Methods The evaluation was conducted during three, 3-month periods for 3 years and included the use of community viral load, global positioning system tracking data, and statistical testing to evaluate the effectiveness of the pilot project. Results The proportion of time spent outreach testing in high viral load areas (69%–84%, P the overall number and percent of HIV positives ((60 (3%) to 127 (6%), P The number and percent of new diagnoses (3 (0.1%) to 6 (0.2%)) and high viral load positives (5 (0.2%) to 9 (0.4%)) increased, but the numbers were too small for statistical testing. Discussion These results suggest that using community viral load to increase the efficiency of HIV outreach testing is feasible and may be effective in identifying more HIV positives. The pilot project provides a model for other public health practice demonstration projects. PMID:29420450

  10. Evaluation of test intervals strategies with a risk monitor

    International Nuclear Information System (INIS)

    Soerman, J.

    2005-01-01

    The Swedish nuclear power utility Oskarshamn Power Group (OKG), is investigating how the use of a risk monitor can facilitate and improve risk-informed decision-making at their nuclear power plants. The intent is to evaluate if risk-informed decision-making can be accepted. A pilot project was initiated and carried out in 2004. The project included investigating if a risk monitor can be used for optimising test intervals for diesel- and gas turbine generators with regard to risk level. The Oskarhamn 2 (O2), PSA Level 1 model was converted into a risk monitor using RiskSpectrum RiskWatcher (RSRW) software. The converted PSA model included the complete PSA model for the power operation mode. RSRW then performs a complete requantification for every analysis. Time dependent reliability data are taken into account, i.e. a shorter test interval will increases the components availability (possibility to e.g. start on demand). The converted O2 model was then used to investigate whether it would be possible to balance longer test intervals for diesel generators, gas turbine generators and high pressure injection system with shorter test intervals for the low pressure injection system, while maintaining a low risk level at the plant. The results show that a new mixture of test intervals can be implemented with only marginally changes in the risk calculated with the risk monitor model. The results indicate that the total number of test activities for the systems included in the pilot study could be reduced by 20% with a maintained level of risk. A risk monitor taking into account the impact from test intervals in availability calculations for components is well suited for evaluation of test interval strategies. It also enables the analyst to evaluate the risk level over a period of time including the impact the actual status of the plant may have on the risk level. (author)

  11. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.